APAR status
Closed as program error.
Error description
AIX lpar may end up with a crash with stack showing vfc_process_mad. Particularly observed on P9 and above. The AIX vfc client driver did not synchronize the command buffer before sending the cmd address to VIOS vfc-host. Consequently VIOS vfc-host would process a stale cmd and when the response for stale cmd is processed on AIX lpar, it might crash the operating system.
Local fix
Problem summary
AIX lpar may end up with a crash with stack showing vfc_process_mad. Particularly observed on P9 and above. The AIX vfc client driver did not synchronize the command buffer before sending the cmd address to VIOS vfc-host. Consequently VIOS vfc-host would process a stale cmd and when the response for stale cmd is processed on AIX lpar, it might crash the operating system.
Problem conclusion
Code fix to synchronize the command buffer before sending the cmd to VIO.
Temporary fix
Comments
7100-05 - use AIX APAR IJ28592 7200-05 - use AIX APAR IJ27786
APAR Information
APAR number
IJ28592
Reported component name
AIX V7.1
Reported component ID
5765H4000
Reported release
710
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-10-07
Closed date
2020-10-07
Last modified date
2021-02-12
APAR is sysrouted FROM one or more of the following:
IJ27786
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AIX V7.1
Fixed component ID
5765H4000
Applicable component levels
R710 PSY U885124
UP20/11/04 I 1000
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11R"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"710","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]
Document Information
Modified date:
18 April 2022