IBM Support

II11513: OEM BUGS IN VSAM, CAT. & IDCAMS CAUSED BY OEM PROGRAMS OR OTHER IBM PRODUCTS. SEE II10001/11013/12140/12615/13278/14105

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as canceled.

Error description

  • Continuation of II10001 and II11013 - VSAMBUGS infoapar3
    "Bugs" caused by OEM products or other IBM products in VSAM,
    Catalog and IDCAMS components:
    #105) Receive msgIEC070I 112-204 when trying to extend a VSAM
          file to a new volume while using PROSMS (STOPX37).  Boole
          & Babbage ZAP# PR351C18 resolves this.
    #106) ABEND0C1 in module IFG0192A was issued accompanied
          by user abends U4095 and U0140 in the IMS control
          and DBRC regions.
          Analysis indicates ABEND0C1 in nucleus mod IEAVEPST
          caused by "wild branch" from ACF2 mod ACF9292A.
          The fix is from CA1 # LO29827. (L oh, not L zero)
    #107) ABEND0C4 caused by a program check due to an
          unresolvable page fault.  BMC was called by
          IDA019R0 with comment, "RESTORE USER REGISTERS
          AND CALL THE USER ROUTINE", possibly during the
          JRNAD routine.  Recovery Plus CICS
          No BMC fix currently available.  (55608,B004)
    #108) ABEND0C9 IN ICYRBA+X'624' LPMB POINTER OBTAINED FROM EDB
          IS ZERO. HAPPENS WHEN RUNNING SOFTWORKS (VSAM ASSIST)
          CONTACT SOFTWORKS FOR THE FIX. Fix no. is VAS66204
    #109) IDCAMS DELETE and DEFINE of a VVDS gives msgIDC3009i
          RC50 RSN12 ( 050-012 ) indicating that allocation failed,
          this occurred under DFSMS r1d0 (unknown if it might occur
          at earlier releases).  The VVDS generated does not con-
          tain a VVCR record.  The 1st record in VVDS is the Z rec
          followed by a VVCN rec.  From a tracks print of the
          SYS1.VVDS the 1st rec or VVCR rec does not contain length
          fields or any valid data.
          It was then discovered that the maintenance level of SAMS
          Allocate (9835) being run had many problems.  PTF in
          error was SS04163, problem no. is PI 363411 and the fix-
          ing PTF is SS04329.
    #110) Running DFSMS r1d0 receive ABEND0c4-10 in CAS (Catalog
          Address Space).  ( ABEND0c4 RC10 or RSN10 )
          CA1 problem, do not have particulars.
    #111) ABEND0C9 in ICYRDWR ICYRBA +x'624' while
          running Softworks VSAM-Assist.
          See Softworks fix VAS66203, VAS66204.
    #112) ENQUEUE ENQ hang with SYSVSAM and SYSZTIOT with CPCS
          product when using PROSMS. PROSMS ZAP PR351C11 corrects
          a problem in prosms with processing of IAM ds's.
          IAM is an access method from Innovation Software.
    #113) TSO session hang while recalling a dataset. Module
          PRS05001 of SPACEVIEW, a Boole Babbage product, caused
          an enq lockout on SYSZTIOT. Temporary solution: Turn
          off one of the global options in SPACEVIEW
    

Local fix

  • #114) IDCAMS REPRO used to re-organize a VSAM KSDS used by OEM
    INFOPAC product from Mobius result in MSGIDC11705I in EXAMINE or
    MSGIEC161i 064(004)086 on OPEN of the KSDS. The KSDS is the OEM
    INVERS1 or INDIST1 defined with SHROPTIONS(4,3) making it "user"
    responsibility to assure read/write data integrity and resource
    serialization. The INFOPAC product has option flag ( OPTION28 )
    flag to be set to 'Y' yes or 'N' no indicating whether the ds is
    to be shared by INFOPAC programs on multi-systems. Be sure to
    set it to Yes if the ksds is to be shared.
    #115) 1/14/99 Abend878-14 in IDA0557A offset d6e at uw30632
          running PROSMS (STOPX37). Boole & Babbage fix pr352pf3.
    #116) 1/20/99 OS390 1.2  DFSMS 1.3
          define a VSAM file on a new volume with no vvds yet
          vvds is created but define another vsam file gets
          IDC3026I (DUPLICATE DATA SPACE NAME ON VOLUME) and
          IDC3009I(VSAM CATALOG RETURN CODE IS 172 REASON CODE IS
          IGGOCLEW-2). SAMS Allocate pe ptf ss04163 resolving
          ptf ss04329.
    #117) 2/4/99 OS390 1.3  DFSMS 1.3
          HSM gets dump with title:
          TITLE=JOB=HSM     ,CAS ESTAE-5695DF105 R1C0,ABEND0C4,
                UNKNOWN +0000,FMID=HDZ11C0 ,MAINT=NONE
          PSW points to oem module ctsapi26. Resolved via CA fix
          L029908.
    #118) MSGIEC070I 210(8-17217)-213 when extending VSAM, SMS
          managed, guaranteed space ds with more then 1 candidate
          volser and is under the control of Sterling Softwares
          SAMS Compress product ( AKA SHRINK ). Fix from Sterling
          apar SA04459.
    #119) OEM vendor SYSTEMWARE, product XPTRMAIN started task
          TCB in a wait in XPTRMAIN code during VSAM GET
          operation after applying Systemware maintenance
          SWJ5596, SWJ5594, SWJ5610, SWJ5611, SWJ5627, SWJ5628.
          Problem resolved with Systemware fix SWJ5630.
    #120) MSGIGD17103I rc140 rsn102 when restoring a VSAM dataset
          using dss.  Various messages: msgADR447I msgADR709E
          msgIGD306I msgADR809I msgADR499I msgADR380E msgADR480W
          Problem is fixed by PROSMS ZAP PR352C35.  See also PDDB
          item RTA000137907.
          Customer had this problem with ProSMS at 3.5.2 put level
          6 and fix PR352PFC on.  ProSMS gave them fix PR352PG7 and
          problem was corrected.
    #121) CICS AEIU abend logical error 02089000
          ( RC8 error code x'90' ) "pointer in AIX with no
          base record." VSAM cluster compressed by OEM VCP
          product from Softworks. Compressed cluster cannot
          have an AIX. Alternate Index.
    #122) abend438 in igg0lf5 + 09b2 caused by ZEKE (Attai software
          product)overlaid the address of UCBCHAN with zeroes UCB
    #123) 3/2/99 Running CDBUTIL from oem CDB Software experiencing
          abend878 resolved via zap B1092061.
    #124) Received error message IEC070I 214-212 when doing a
          restore replace a dataset. No error message when deleted
          the dataset first. Changes in allocation rules for SAM
          fixed the problem.
    #125) VSAM CICS DS using Sterling Software SHRINK product.
          FCIOWAIT with PLH deferred on DIWA. SHRINK has called
          a JRNAD exit. SHRINK ptf SS04478 fixes problem.
    #126) Define of sys1.xxxx dataset from ispf 3.2 is not being
          prompted for mcat password even though the mcat is defined
          with master and update passwords. ACF2 fix LO27183.
    #127) ABEND18A IGC121 with recursive abend0c4 in IGG0CLA9
          at offset x'174C' due to an overlaid PLH header.
          Problem in Boole and Babbage Auto Operator AO module
          DXALRT. Fix number from B&B is BPI7519.
          Additional symptoms for this Boole & Babbage overlay:
          Msgiec161i rc52 rsn72 pdf72 due to broken or invalid
          VSI or VSICHAIN because the VSINXT field was overlaid
          with Zeros or ZEROES.
    #128 MSGIDC3009I RC50 RSN96 050-096 during
          create of DB2 Table. Compuware product
          RDS needs fixing PTFs IN325V03 and
          IN324V01         (14320,278-04/99)
    #129) Batch job hangs in an ECB wait on OS390 r3 DFSMS r1C0.
          Job appears to be in the process of an OPEN of an ESDS
          for output.  Job sometimes runs OK, sometimes hangs.
          The WAIT is in TMASEXEC prior to any VSAM OPENs.
          Imagesoft Technologies provided replacement module for
          VISVGCIF at service level uw36401, for product
          Docubanc version 3.0.
    #130) After migrating from CICS 4.1 to CICS TS 1.2
          (CICS 5.2) began experiencing ABENDA78-10 and
          ABEND878-18 during a transaction that closed all
          files.  Fixed by BMC ZAP number PR352PHK for ProSMS.
          NOTE:  This is not a formal fix.
    131) Non-RLS OPEN of file MCHSTDS failed. IGWARLS call returned
         X'000C', X'000E' & problem determination X'00000000000000'
     or x'0010', x'0004' & problem determination x'000000080000002A'
         module DFHFCFS. Error occurs opening IAM file. IAM =
         Innovation Access Method from Innovation Data Processing.
         SOLUTION: Change IAM Global option LOADABWO to YES and
         restart IAM. DFHFC0520 MSGDFHFC0520
    132) Catalog service task tcb holding SYSIGGV2 major
         resource while in a wait in CA TMS ( Computer
         Associates Tape Management System ) csect TMS0YIOL.
         Other TCBs hung on major resource TMSQNAME minor
         TMS-AUD or TMS-TMC. CA zap # T5Q4134.
    #133 MSGIEC070I 108-204 -> MSGIEC161I RC108 and
         MSGIDC3351I RC28 RPLFDBWD = x'2908001C' using
         PROSMS with DFSMS R1D0 after applying uw54391.
         Boole & Babbage B&B zap number PR352PED with PRE-
         REQ PR352PB1.
    #134 ABEND0C4 PIC=10 at IECDPRFX +x'2A6' and R5
         with bad address.  Field IOSXIOD has high-
         order byte overlayed with zeros. CA90
         Services (L9901) and module CASR230E. CA fix
         is T7M8518.
    #135 Abend0c4 with BMC software; ACB flags
         incorrectly request VSAM buffers to be
         built above the line. IBM fix OW35603.
    #136 Abendc78 CAIMB838 CA90 causes CAS to hang in
         SYSIGGV2.  Needs to bring genlevel of CA90
         to a more current level 9901 for OS390 support.
    #137 AFCZ dfhFC0001 abends on CICS/ESA R410 region.
         ABEND0C4 x'5FA' in IDA019R2 (UW44357) level.
         INDEX BUFC address all 0's zeroes zeros.
         Computer Associates CA Top Secret TS product
         fix numbers FC45168 and FC45165.
    #138 ABEND0C4 in IDA0192S with a bad reg14 opening AIX
         PATH in CICS. Offset at or near x'39A'. OEM
         Sterling - SAMS:Allocate Product APAR number SA04670.
    #139 After conversion to OS390 2.5, a COBOL program with
         CA OPTIMIZER went into a loop / wait.  Solution was
         to upgrade OPTIMIZER from r5.0 to r6.0.
    #140 ABEND0C4 IDA019RE using SAMS COMPRESS and
         receive SAMS COMPRESS message:
         +ZSUR010I AREWORK ALREADY ACTIVE
         ZAP from SAMS COMPRESS support to fix.
         PTF number SS03720.
    #141 OEM program Control-R is creating invalid dataset
         names using dynamic allocation.  First reported in
         BDC000011455.  Fixed by Control-R's PTF's: FIO4301,
         4313,4314,4315,4710 and FRO0108,0121,0139,0140.
         J.O. 07/01/99
    #142 CICS 4.1 region in FCIOWAIT with an abend0c4
         IDA019RH at x'A0' or x'2C'. CB ICWA overlaid
         with ebcdic "KTRE" and KCBX" all preceeded by
         abend0c4 in Computer Associates CSECT CAKSROUT.
         CA fixes FC45165 and FC45168.
    #143 7/9/99 MSGIEC070I 104-204 and MSGIDC3351I RC28
         RPLFDBWD 2908001C during idcams repro to a ksds.
         Resolved via SAMS COMPRESS 9924 maintenance level.
    #144 ABEND978 in IDA0200T issued on FREEMAIN of DEB
         extension. Using Sterling Software SHRINK / COMPRESS
         release 5.2. Needs fixing PTFs SS04671 and SS04731.
    #145 Specifying RMODE31=CB or RMODE31=ALL should place the VRSB
         and IDAHEB control blocks above the line.
         There is a problem with SYNCSORT when the sortinxx or
         sortoutxx datasets are VSAM. Syncsort does not specify
         RMODE31 on the ACB and thus the buffers  get allocated
         below the line.  When RMODE31 is spedified in the AMP
         statement in JCL an abend0C4 occurs.  SYNCSORT  has two
         fixes to resolve this problem: SY45601 and SY52290. By
         applying these two fixes and coding RMODE31=ALL in the jcl
         usage of CSA/SQA will be above the line.
    146) Running a SAS PC application that interfaces with OS390
         and does a pseudo TSO logon to OS390 and receives the
         following messages:
        *CAG8001E CAN NOT OBTAIN WORK AREA. BYPASSING API.
         IEC340I - IGC0002F, INSUFFICIENT STORAGE FOR CATALOG WORK
         IEC251I 037()-006,SAS900,SASSTEP ...
         IEC161I 020-054,SAS900,SASSTEP ...
         PQ22953 / UQ26019 is applied to system.  Customer discover-
         ed that when BMC's HiperCache product removed problem no
         longer occurs.  Called customer and requested a BMC fix#.
    .
    147) Msgiec070i rc104 rsn204 rc209 rc108 rsn211 with PROSMS
         after installation of ow32008 and other Vsam eov apars
         Prosms Fixes that fix the Vsam EOV hook interface
         PR352PED - adds support for OW32008
         PR352PGD   These all resolve volume switching problems
         PR352PH1
         PR352PHH
         PR352PHU
    #148 MSGIEC027I IEC027I 737-04 MSGIEC211I IEC211I
         314-04 trying to REPRO to physical sequential
         extend format files.  PROSMS zap PR352PG8
         (Also see BDC000012033)
    #149 FDRCOPY:FDRDSFAL:MSG ICH408I,ACF04056,FDR332, OR
         SECURITY VIOLATION MESSAGE FROM TOP SECRET.
          False RACF Facility Class security error for
          Delete Noscratch
         ZAP-ID#   : P-53.3064
    150) 9/13/99 ABEND0C4 in IDA121A3 +x'C0' trying to LOAD the
         TCBJSTCB to update necessary stats for a normal I/O end.
         The DETACH, issued by code in a Candle module, is issued
         before the I/O for the PUT is complete.  Candle incident
         #630720 opened.  OEM sent customer new release of CMS
         (v300).  This particular problem was fixed by procedural
         changes by operations.  There is no OEM fix, just a
         recommendation as to what order specific tasks associated
         to this package are to be taken down.  (PMR66311,500,000)
    151) MSGIEC070I 034-202 " DS would exceed 4gig limit if
         extended" on a ds with SMS DATACLAS with EXTENDED
         ADDRESSABILITY=YES. A LISTCAT of the ds shows the
         EXTENDED attribute for extended format, but does not
         show EXT-ADDR for extended addressability. The correct
         sms dataclas is also shown in the listcat.
    SOLUTION: the DS had been re-orged using INNOVATION product
         FDREORG at level R5.2 L50 which does not include support
         for extended addressability. FDREORG at R5.3 L35 supports
         extended addressability and solves this problem.
    152) Index component of a TEMPORARY TEMP VSAM KSDS is
         not deleted at job / step end. Using OEM product
         IAM from INNOVATION Software fix numbers P640047
         and PR640038.
    153) 10/22/99 Abend0c4-10 in igg0clxc ptf uw55493 level offset
         x'12ac' in a password check routine. Catalog call issued at
         offset x'8b4' into csect pspcsd22 with eyecatcher
         csect=pspcsd22 11/28/97 07.57 fmid=swps220 copyright (c)
         1997 softworks, inc. Resolved via non-specific fix(es) to
         software package Performance Essential from Softworks, Inc.
    154) 10/28/99 Abend0c4-4 in igg0clfs hdz11d0 base level offset
         x'167a'. Catalog call with defective parameter list issued
         out of load module with eyecater ezymain from ca. Resolved
         via fixes 731-40 and 731-58 to pdsman catalog manager.
    #155) ABEND0C4 in load mod IGG0CLX0 after command
          F CATALOG,OPEN.  A CAXWA (CAX) was overlaid with OPSMVS
          message information such as RCSSSSM as an eycatcher.
          Also, CSAMSG2 VARY xxx ONLINE.
          CA product OPSMVS fixes OP42221 and OP42222.
    #156) ABEND0C4 in IDA019RT at or near offset x'AB4'
          depending upon ptf level. OEM utility in use
          which loads a VSAM ds to a sequential file.
          User supplied RPL ( Request Parm List ) points
          at a RPLAREA which extends 4 bytes past the
          end of the storage getmained for the RPLAREA.
          OEM vendor is MAINSTAR Software, OEM product is
          V4R401B and up. The OEM fix number is PTF06789.
          11/18/99.
    #157) STERLING SOFTWARE DMS ( sams disk ) product refers
          to PRIMARY SPACE allocation quantity in catalog entry
          when migrating a ds to slower dasd. It uses the primary
          space quantity to allocate new space on the slower
          dasd, even in PARTREL ( partial release ) has reduced the
          allocated space of the ds on its original volume.
          DMS put level PD9924 changes DMS to refer to the
          HURBA/HARBA info of the catalog entry instead of primary
          space quantity.
    #158) STERLING SOFTWARE DMS ( sams disk ) product attempts
          to recall dataset during DELETE NOSCRATCH request.
          The fix number is SS05416 on DMS put level PD0034.
    #159)  ABEND0C4,IGG0CLXC+1490
    Invalid CPL provided by Softworks module .
      CSECT=PSPCSD22  11/28/97 07.57 FMID=SWPS220    COPY
    The SVC is issued at +x'8B4' in PSPCSD22 .
    Address at +x'18' in the PLIST is x'40404040'
    Softworks fix is PSP22310 .
    

Problem summary

Problem conclusion

Temporary fix

Comments

  •  vsam infoapar3
    

APAR Information

  • APAR number

    II11513

  • Reported component name

    V2 LIB INFO ITE

  • Reported component ID

    INFOV2LIB

  • Reported release

    001

  • Status

    CLOSED CAN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    1998-11-10

  • Closed date

    2000-01-03

  • Last modified date

    2005-10-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z\/OS"}],"Version":"001"}]

Document Information

Modified date: