IBM Support

II10548: ENVIRONMENT DIRTY CAUSED BY LOAD OF UNCONTROLLED MODULE FROM HFSTCBNCTL SET BY OPENEDITION.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as canceled.

Error description

  • Please review APAR OW44655 which introduced
    enhanced program control support. The support is available at
    OS/390 R8 and above. The enhanced support works with OEM
    security only if they support the new SAF callable service
    IRRENS00.
    Environment dirty is normally caused by the sticky or the
    program controlled extended attribute not being set for a module
    loaded from the HFS or failing to load a module from a
    controlled MVS library, when the BPX.DAEMON facility is active.
    The program controlled extended attribute is ignored for
    executables residing in HFS filesystems mounted with the
    nosetuid or ignore-setuid option. The second page ofthe ISHELL,
    File_systems, Mount Table, Attributes panel will show if the
    ignore-setuid attribute is on (1=on). MVS libraries are
    controlled by defining profiles to the RACF PROGRAM class. You
    can define the program class using the RACF RDEFINE commands. If
    the PROGRAM class is already active, profiles can be added or
    altered using RALTER. After OS/390 R4 or with OW24881 installed
    a volser need not be specified on the RDEFINE / RALTER:
     RDEFINE PROGRAM * ADDMEM ('SYS1.LINKLIB'//NOPADCHK) UACC(READ)
     RALTER  PROGRAM * ADDMEM ('CEE.SCEERUN'//NOPADCHK) UACC(READ)
     RALTER  PROGRAM * ADDMEM ('SYS1.SEZALINK'//NOPADCHK) UACC(READ)
    A specific volser or '******' also may be specified:
     RALTER  PROGRAM * ADDMEM ('CEE.SCEERUN'/'******'/NOPADCHK)
      UACC(READ)
     RALTER  PROGRAM * ADDMEM ('CEE.SCEERUN'/123456/NOPADCHK)
      UACC(READ)
    Datasets for profiles defined with '******' as volsers must
    reside on the the IPL volume if there are multiple sysres
    volumes. Otherwise '******' indicates the current sysres volume.
    Changes made to the program class must be refreshed in storage
    with command:
      SETROPTS WHEN(PROGRAM) REFESH
    To display the profiles in the RACF program class use:
      RLIST PROGRAM * all
    The slip below will produce trace records whenever an HFS module
    is loaded. If the program control extended attribute is not set
    for a module loaded from the HFS, then that module will be the
    cause of the setting of the dirty bit. If the slip is set
    correctly and no records are produced, then the dirty bit is
    likely being set by the security product. See RACF APAR II08176
    or contact OEM security for additional diagnostics. See "Note"
    under step 2 below, too.
    -
    To determine if the HFS version of the module is causing
    Environment dirty, follow these steps:
    ---------------------------------------------------------------
    1. Run an AMBLIST of BPXINLPA to get the offsets of
    BPXPRLOD and BPXPRECP.
    2. Start GTF using Jobname prompting and a Jobname wildcard.
    Note: In most cases Jobname prompting captures the data needed.
    However, when the trace data shows NO DATA - you may then want
    to run it again WITHOUT Jobname prompting and a Jobname
    wildcard (but be aware that this *will* result in checking
    being performed for *all* HFS loads across *all* environments).
    ---------------------------------------------------------------
    s gtf.gtf
    r xx,trace=slip,jobnamep
    r xx,jobname=job*
    r xx,end
    r xx,u
    Or, per "Note" in step 2:
    s gtf.gtf
    r xx,trace=slip
    r xx,end
    r xx,u
    --------------------------------------------------------------
    3. Set slip to catch setting of TCBNCTL in BPXPRECP & BPXPRLOD.
    xxxx, yyyy, zzz, and www are determined below depending on the
    level of the modules.  The smallest of xxxx and yyyy is placed
    in position1.  The other is placed in position2.  The slip must
    be set before starting the daemon.  TCBNCTL is set as the daemon
    executables are loaded on startup.
    --------------------------------------------------------------
    slip set,if,a=trace,
    l=(bpxinlpa,position1,position2),trdata=(std,regs,
    GRr?+zzz?,+7,GRr?+zzz?,+F,GRr?+zzz?,+17,GRr?+zzz?,+1f,
    GRr?+zzz?,+27,GRr?+zzz?,+2F,GRr?+zzz?,+37,
    13r?+www?,+7,13r?+www?,+F,13r?+www?,+17,13r?+www?,+1f,
    13r?+www?,+27,13r?+www?,+2F,13r?+www?,+37),end
    (GR = 13 unless otherwise stated)
    --------------------------------------------------------------
    4. Set slip to ignore the intermediate instruction range in
    BPXINLPA. Add 1 to the value in position1 and subtract 1
    from the value in position2.
    ---------------------------------------------------------------
    slip set,if,a=ignore,l=(bpxinlpa,position1 +1,position2 -1),end
    ===============================================================
    Module offsets by release. Additional release levels will be
    documented as needed. Contact OpenEdition Level 2 support.
    ---------------------------------------------------------------
      Where xxxx is the offset of BPXPRLOD within
        BPXINLPA plus the offset noted below
        in the middle column:
    ---------------------------------------------------
    BPXPRLOD      xxxx    zzz     GR  (GR=13 unless otherwise noted)
    ---------------------------------------------------
      HOM1130:
        BASE      096A    9BC
        UW20427   096A    9BC
        UW22904   0952    9BC
        UW31085   0962    9BC
        UW33197   0962    9BC
        UW37004   0962    9BC
        UW40861   0962    9BC
        UW42129   0962    9BC
      HOM1140:
        BASE      095A    9BC
        UW31086   096A    9BC
        UW31315   09CE    9BC
        UW33198   09CE    9BC
        UW40862   09CE    9BC
        UW42130   09CE    9BC
      HBB6603:
        BASE      09CE    9C4
        UW40860   09CE    9BC
        UW42128   09CE    9BC
        UW42861   0A2E    9BC
        UW44424   0A2E    9BC
        UW45424   0A2E    9BC
      HBB6604:
        BASE      0A54    9CC
        UW40863   0A54    9CC
        UW42131   0A54    9CC
        UW42862   0AB4    9CC
        UW44426   0AB4    9CC
        UW44477   0A84    9CC
        UW45426   0A84    9CC
      HBB6605:
        BASE      0AFA    A64
        UW44476   0ACA    A5C
        UW49279   0ACA    A5C
        UW51851   0AD2    A5C
        UW53340   0AD2    A5C
      HBB6606:
        BASE      0A6C    A94
        UW51852   0A74    A94
        UW53341   0A74    A94
        UW60608   0A7C    A94
        UW64401   0A84    A94
      JBB6607:
        BASE      0A74    A94
        UW53342   0A74    A94
        UW60610   0A74    A94
        UW62103   0A74    A94
        UW64403   0A84    A94
        UW70442   0A84    A94
        UW71338   0A84    A94
      HBB6608:
        BASE      0ABC    A94
        UW60609   0AC4    A94
        UW64402   0ACC    A94
        UW71336   0ACC    A94
        UW70440   0ACC    A94
        UW74956   0BE4    66D  GR = 4
     JBB6609
        UW64404   0D3A    C04
        UW67407   0D3A    C04
        UW74958   0E52    7DD  GR = 4
        UW76973   0E52    7DD  GR = 4
      HBB7703:
        BASE      0DCA    7AD  GR = 4
        UW70441   0DCA    7AD  GR = 4
        UW71337   0DCA    7BD  GR = 4
        UW74957   0E16    7C5  GR = 4
        UW76972   0E16    7C5  GR = 4
        UW81105   0E16    7C5  GR = 4
    HBB707
        UW96005   1384    C3D  GR = 4
    ===================================================
    BPXPRECP      yyyy    www
    ---------------------------------------------------
      Where yyyy is the offset of BPXPRECP within
        BPXINLPA plus the offset noted below
        in the middle column:
    ---------------------------------------------------
      HOM1120:
        UW10117   0CD8    18C
        UW31174   0CD8    18C
      HOM1130:
        BASE      0E3A    198
        UW20427   0FDA    198
        UW27688   0FDA    198
        UW30664   102A    198
        UW31175   102A    198
        UW33844   115A    198
        UW37004   115A    198
      HOM1140:
        BASE      1018    198
        UW30665   1068    198
        UW31176   1068    198
        UW31368   1040    198
        UW33845   1174    198
        UW36927   11A0    198
        UW46065   1216    198
      HBB6603:
        BASE      111E    198
        UW33843   1246    198
        UW34960   125A    198
        UW36926   128E    198
        UW38319   127E    198
        UW41243   127E    198
        UW42861   1356    1C8
        UW44964   138E    1C8
        UW46063   1404    1C8
        UW46905   141C    1C8
        UW48369   1442    1C8
        UW49989   145C    1C8
      JBB6604:
        BASE      12B0    198
        UW38320   12B0    198
        UW39438   12F0    198
        UW41244   12F0    198
        UW42862   13C8    1C8
        UW43065   13CA    1D0
        UW44966   140A    1D0
        UW46066   1480    1D0
        UW46909   1498    1D0
        UW48372   14BE    1D0
        UW49992   14D8    1D0
        UW59761   14D0    1D0
      HBB6605:
        BASE      1412    218
        UW44965   1492    210
        UW46064   1508    210
        UW46906   1520    210
        UW48370   1546    210
        UW49279   155E    210
        UW49990   1578    210
        UW53340   15B0    210
        UW54287   1630    218
        UW56448   16AA    210
        UW59758   16AA    210
      HBB6606:
        BASE      1538    210
        UW48371   155E    210
        UW49991   1578    210
        UW53341   15B0    210
        UW54288   1630    210
        UW56449   16AA    210
        UW59759   16AA    210
        UW60608   16B2    210
        UW64401   16BA    210
      JBB6607:
        BASE      1668    210
        UW53342   16A8    210
        UW54289   172E    210
        UW56450   179E    210
        UW59762   179E    210
        UW60610   17A6    210
        UW62103   1BA6    214
        UW63768   1BA6    214
        UW64403   1BAE    214
        UW75362   1BBA    214
      HBB6608
        BASE      1A52    210
        UW59760   1A52    210
        UW60609   1A5A    210
        UW62102   1C0E    214
        UW63767   1C0E    214
        UW64402   1C16    214
        UW71593   1C1A    214
        UW74956   1CC0    230
      JBB6609
        UW64404   1C5A    214
        UW74958   1D06    230
        UW75363   1D12    230
      HBB7703:
        BASE      1C40    22C
        UW71594   1C44    22C
        UW74957   1C8E    230
        UW75361   1C9A    230
    ===============================================================
    Trace records will build the pathname of the uncontrolled
    HFS module, 8 characters at a time. Building the pathname
    8 characters at a time is necessary because, the variable
    length storage for the pathname structure is obtained at the
    time of the load. If GTF is requested to trace a data area
    that runs into unallocated storage, it will return 0 bytes
    in the trace record. We therefore can not attempt to trace
    a maximum length pathname in a single trace record because we
    run the risk of having nothing returned when storage for the
    pathname structure is of a length less then the assummed
    maximum. We know that storage is obtained a doubleword at a
    time so we can increase the length of the trace record by eight
    bytes until we reach the assumed maximum length of x'38'
    characters. If any of the later trace records try to access
    unallocated storage and get zero'd out by GTF, the earlier
    trace records will already have captured the pathname.
    JRENVDIRTY 090C02AF REASON 02AF 157 ERRNO=157
    Examples: Problem encountered with RLOGIN. Users could not log
    on. Reason JRENVDIRTY
    Problem resolved as follows: The problem was with the "program
    control" bit of /usr/sbin/rlogind. This bit was off and caused
    the program to turn up dirty. Using ISHELL or extattr +p to turn
    

Local fix

Problem summary

Problem conclusion

Temporary fix

Comments

  •  Closing for searchability.
    

APAR Information

  • APAR number

    II10548

  • Reported component name

    V2 LIB INFO ITE

  • Reported component ID

    INFOV2LIB

  • Reported release

    001

  • Status

    CLOSED CAN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    1997-06-03

  • Closed date

    1999-02-26

  • Last modified date

    2023-04-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19M","label":"z\/OS Communications Server"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"001"}]

Document Information

Modified date: