APAR status
Closed as canceled.
Error description
This APAR was opened to document commom problems encountered during the DB2 IVP process. ---------- install installation migrate migration ================================================================ SQLCODE805 Plan not found. Program library may be missing from the DFHRPL DD concatenation found in the CICS startup proc. ================================================================ MSGIGYPG3123-W will be received in DSNTEJ3C if the COBOL II compiler is Version 1.3.1. A RC04 will be received in steps PH03CS01.COB2 and PH03CS04.COB2. ================================================================ DSNTEP2 U4000 & IBM002I & IBM019I - add a PLIDUMP DD statement to step & parm=('nospie,nostae/') - if S0C4 PIC11 in DSNTEP2+ 173C - error is caused by mixed libraries. If PL/I R230, verify that libraries in SYSLIB in the link step are R230. ================================================================ ABEND0C4 PIC11 in DSNTEJ3P in DSN8SP3 with Pl/I. See PL71117 for resolution. ================================================================ ABEND30E in IVP executing DSNTEP2. Abend is in IBMBERR1. IF NOSTAE & NOSPIE is specified the ABEND30E is eliminated but now an ABENDU4000 is received. The ABENDU400 is traced back to the link edit step; where the PL/I libraries specified had mixed versions of PL/I (in one case there was a mixture of V1R3 and V1R5 modules). ========================================== LE ABENDU4093 RC1C can occur if user does not specify enough Region on jobcard when executing DSNTEP2. Running under LE requires more storage than previous releases of PL/I. ================================================================ Create Tablespace fails under DSNTIAD or DSN command processor ABEND0C4 PIC10 or ABEND04E RC00E50013 DSNTFRCV. Problem due to third party PDS management system. Call to IDCAMS was intercepted. Z page for note. ================================================================ " MSGIEC020I 001-4 " and " MSGIEC020I DCB EROPT=ABE OR AN INVALID CODE, and/or NO SYNAD EXIT SPECIFIED " may be returned from DSNTIAD if the SYSIN input file is empty. ================================================================ ABENDU476, ABENDU0476, ABEND106 can occurr in the PL/I IVP for IMS if the customer is using PL/I 1.5. Job DSNTEJ4P was chang- ed for DB2 R230 to support PL/I 2.2 and up. The change that was made was to change the entry statement fom PLICALLA to PLISTART. If the customer wishes to execute the IMS IVP using PL/I 1.5, then he must change the entry statements in DSNTEJ4P from PLISTART to PLICALLA and resubmitt DSNTEJ4P. ================================================================ The DSNH CLIST does not generate the correct data set names for CICS R321 and above. If you are using CICS 3.2.1 or R330 you may edit the DSNH CLIST where the CICS data set names are generated and change them from LOADLIB, COBLIB, and PL1LIB to SDFHLOAD, SDFHCOB, and SDFHPL1 respectively. The six lines that need to be changed are: SET &CICSXLT = &STR('&CICSPRE..LOADLIB(DFHEPP1$)') 3051000 SET &CICSXLT = &STR('&CICSPRE..LOADLIB(DFHEAP1$)') 3053000 SET &CICSXLT = &STR('&CICSPRE..LOADLIB(DFHECP1$)') 3055000 SET &ILIB = &STR(&ILIB '&CICSPRE..PL1LIB') /* LIB */ 3630000 SET &ILIB = &STR(&ILIB '&CICSPRE..COBLIB') /* LIB */ 3633000 SET &ILIB = &STR(&ILIB '&CICSPRE..LOADLIB') /* LIB */ 3639000 DB2 R410 ------------- 7/01/97 PLB -------------------------------------- It should be noted that when running the DSNTEP2 job (written using PL/1 1.5) and compiled using LE/370, a linkage problem may occur and an abendu4000 when using DB2 SPUFI from batch. Please reference: "The PL/1 for MVS and VM Compiler and Run-time Migration Guide", Chapter 9, "Migration Aids" under section "OS PL/1 Version 1 Release 5.1 Main Load Module ZAP" A ZAP (IBMRZAPM) is mentioned (provided by LE/370 support) that needs to be applied to PL/1 1.5 load modules to run under LE/370. IBMRZAPM is an alias for IBMRZPIR provided in SCEESAMP. The publication number is SC26-3118-01. --------------------------------------------------------------- ABENDU4000 (User Abend U4000) and other errors can occur for DB2 PL/I application/s (DSNTEP2 for example) when picking up some but not all modules from the older SIBMxxxx and PLIxxxx libraries and the reset will be picked up from SCEERUN (causing a mixture of releases). To compile,link and run DSNTEP2 using only PL/I 2.3 you need to have the following libraries accessed: * At COMPILE - PLICOMP At LINK - PLIBASE and SIBMBASE At Runtime - PLILINK and SIBMLINK * The LE product ships libraries with OS390 1.2 and above that con the same module names (ALIAS's) that are in PLIBASE,SIBMBASE,PLI and SIBMLINK. These libraries are: * At LINK - SCEELKED At Runtime - SCEERUN * ---------------------------------------------------------------- -------------- 00/09/29 ht ------------ If an SQLCODE -592 is received during the execution of DSNTEJ6S or DSNTEJ6T, please ensure that SPA is active.
Local fix
Problem summary
Problem conclusion
Temporary fix
Comments
CLOSED FOR RETENTION: DB2INFO
APAR Information
APAR number
II06012
Reported component name
PB LIB INFO ITE
Reported component ID
INFOPBLIB
Reported release
001
Status
CLOSED CAN
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
1992-05-08
Closed date
1995-10-25
Last modified date
2000-09-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSEPEK","label":"Db2 for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
13 December 2020