A fix is available
APAR status
Closed as program error.
Error description
When a device-specific MIH interval has been defined (for example SIR MIH,181=10M) and an interrupt becomes missing for this device, the operator msg AR+0013 0E04D P DEVICE 181 LOST DEVICE END is issued after the device-specific MIH interval. If the interrupt continues to be missing, the device-specific MIH interval is not used anymore to trigger the next occurrence MSG0E04D. Instead, the overall MIH time interval (which is usually much lower) is used.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of SIR MIH command. * **************************************************************** * PROBLEM DESCRIPTION: Incorrect logic when calculating a * * device missing interrupt time and * * comparing it with the device-specific * * SIR MIH value. * **************************************************************** * RECOMMENDATION: Apply APAR. * **************************************************************** When a device-specific MIH interval has been defined (for example SIR MIH,181=10M) and an interrupt becomes missing for this device, the operator msg AR+0013 0E04D P DEVICE 181 LOST DEVICE END is issued after the device-specific MIH interval. If the interrupt continues to be missing, the device-specific MIH interval is not used anymore to trigger the next occurrence of MSG0E04D. Instead, the overall MIH time interval (which is usually much lower) is used. With the second (and all following) missing interrupt interval the device missing interrupt time was incorrectly calculated and compared with the device-specific SIR MIH,181=tt value.
Problem conclusion
Incorrect logic for calculating the device missing interrupt time has been corrected.
Temporary fix
Comments
APAR Information
APAR number
DY47682
Reported component name
VSE/AF SVR/BAM
Reported component ID
5686VS606
Reported release
61C
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-08-11
Closed date
2016-08-15
Last modified date
2016-08-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UD54204 UD54205
Modules/Macros
$$A$SUPI SGMIH SGSRVLVL
Fix information
Fixed component name
VSE/AF SVR/BAM
Fixed component ID
5686VS606