A fix is available
APAR status
Closed as program error.
Error description
When operator issues 'PFLUSH partition' and a subsystem is found active, e.g. CICS or VTAM or PSF, VSE/POWER issues message 1QZ1D SUBSYSTEM RUNNING IN PARTITION partition-id .... The operator is not informed which subsystem is running in the named partition and needs to use additional commands to determine which subsystem is running .
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of PFLUSH command * **************************************************************** * PROBLEM DESCRIPTION: when operators flushes partition by * * PFLUSH command and subsystem is active * * in partition, message 1QZ1D asks for * * confirmation but doesn't name subsystem * * as e.g. message 1I55D does for * * Attention Routine command CANCEL * * * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
VSE/POWER will now show subsystem name as shown by 1I55D . For USER subsystem if will show VSE/AF jobname. IPW$$CF has been modified to insert subsystenm name into message 1QZ1D defined in IPW$GMM/IPW$$MM and modified by IPW$$MX. IPW$$NU has been modified to align POWER PCBs in dump. Update for z/VSE 6.1 Messages & Codes Volume 1, SC34-2682-00 1QZ1D SUBSYSTEM ssystem RUNNING IN PARTITION xx - REPLY 'YES'TO FLUSH PARTITION Explanation: A PFLUSH command was entered for a partition in which the named subsystem runs. The system operator is prompted to confirm the flushing. System action: VSE/POWER waits for the operator's reply. Operator response: Reply 'YES', if the subsystem should actually be canceled. Otherwise type in 'NO' or simply press ENTER. System programmer response: None.
Temporary fix
Comments
APAR Information
APAR number
DY47675
Reported component name
VSE/POWER
Reported component ID
5686VS603
Reported release
61C
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-07-20
Closed date
2016-07-22
Last modified date
2016-08-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UD54196
Modules/Macros
IPW$$CF IPW$$MM IPW$$MX IPW$$NU IPW$GMM
SC34268200 |
Fix information
Fixed component name
VSE/POWER
Fixed component ID
5686VS603
Applicable component levels
R61C PSY UD54196
UP16/08/04 I 1000
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG32M","label":"APARs - VSE\/ESA environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"61C","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
11 December 2020