DY47585: 0S03I PROGRAM CHECK INTERRUPTION IN POWER START IF SETPFIX LIMITIS LARGER THAN SIZE OF PARTITION.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • 0S03I PROGRAM CHECK INTERRUPTION  - HEX LOCATION 00500BA0
    is issued when SETPFIX limit exceeds SIZE definition for POWER
    partition. Expected message 1Q05I should be issued instead.
    1Q05I  PAGEABLE AREA TOO SMALL, INCREASE VALUE OF 'SIZE'
    COMMAND/OPERAND
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Users                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: When VSE/POWER partition layout is      *
    *                      unfit for VSE/POWER, e.g. SETPFIX LIMIT *
    *                      exceeding SIZE, VSE/POWER fails to      *
    *                      write msg 1Q05I PAGEABLE AREA TOO SMALL *
    *                      but cancels with program check instead  *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • Code in IPW$$IP has been changed to ensure correct branch to
    routine IPW$$I1 to write 1Q05I PAGEABLE AREA TOO SMALL
    and then terminate VSE/POWER by CANCEL macro.
    Name of loaded phase will be addressed correctly for 1Q5BI.
    

Temporary fix

Comments

APAR Information

  • APAR number

    DY47585

  • Reported component name

    VSE/POWER

  • Reported component ID

    5686CF903

  • Reported release

    51C

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2014-11-18

  • Closed date

    2014-11-20

  • Last modified date

    2014-11-27

  • APAR is sysrouted FROM one or more of the following:

    DY47584

  • APAR is sysrouted TO one or more of the following:

    UD54080

Modules/Macros

  • IPW$$IP
    

Fix information

  • Fixed component name

    VSE/POWER

  • Fixed component ID

    5686CF903

Applicable component levels

  • R51C PSY UD54080

       UP14/11/27 I 1000

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.