IBM Support

Cristie GigaStream T-Series Autoloader Configuration Information for IBM Tivoli Storage Manager Server

Preventive Service Planning


Abstract

Configuration Information for Cristie GigaStream T-Series Autoloaders

Content


Cristie T8L
Cristie T24L
Cristie T48L
Cristie T96L

Model
Drive Addresses
Storage Slot Addresses
Changer Address
Entry/Exit Slot Address
T8L
1
1001-1008
0
101
T24L
1-2
1001-1024
0
101
T48L
1-4
1001-1048
0
101-103
T96L
1-8
1001-1096
0
N/A

Notes:

1. Library capacity
    8 drives 96 slots

2. Barcodes are supported.

3. Device identifications and firmware levels used during validation
    T8L
    Library : Cristie GigaStream TxxL --- Firmware : 2.10
    T24L and T48L (validated with TSM 5.4.1)
    Library : Cristie GigaStream TxxL --- Firmware : 1.60
    Drive : HP Ultrium-2 SCSI --- Firmware : S53B
    T96L
    Library : Cristie GigaStream TxxL --- Firmware : 1.21

4. ELEMent=AUTODetect in the DEFINE/UPDATE DRIVE command is supported.

5. Available drives


Library and drive may require different minimum Tivoli Storage Manager levels. Therefore, ensure that both library and drive hardware are supported. See "Supported Devices for AIX, HP-UX, Solaris and Windows" or "Supported Devices for Linux" for minimum supported version levels and platforms for these devices.

More information regarding device configuration is available in the Tivoli Storage Manager Administrator's Guide, which can be found in the IBM Tivoli Storage Manager information center.

[{"Product":{"code":"SSGSG7","label":"Tivoli Storage Manager"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Component":"Server","Platform":[{"code":"PF002","label":"AIX"},{"code":"PF010","label":"HP-UX"},{"code":"PF016","label":"Linux"},{"code":"PF027","label":"Solaris"},{"code":"PF033","label":"Windows"}],"Version":"All Supported Versions","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}}]