TEC server crashes seconds after it is started, after there has been a previous crash.
The tec_rule file reports a 211 error.
Collect a rules trace and check if the last line of this file references a .wic file
Cause
When a TEC system crashes it is possible for any .wic files to become corrupted.
Resolving the problem
When a TEC system crashes it is possible for any .wic files to become corrupted.
Delete the corrupted .wic file.
Compile and reload the rules; this will recreate the .wic file.
Restart the TEC server.
Copyright and trademark information
IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.