V4.2.x - Supported Hardware List, Device Driver and Firmware Levels for SAN Volume Controller
|
| | | Abstract | The documents titled Supported Hardware List and Recommended Software Levels provide the operating systems, host adapters, SAN fabric elements, RAID controllers and selected other hardware that have been tested or qualified by IBM.
For operating systems, we show the latest tested release levels and service packs. Later levels than those listed are not supported at this level of SAN Volume Controller Software. Only the listed operating systems are supported.
For host adapters, SAN fabric elements and RAID controllers, we list our currently recommended firmware and/or BIOS levels and formally support only the hardware listed. Later levels than those listed are not supported at this level of SAN Volume Controller Software
For multipathing levels, we show the latest tested release levels. Later levels than those listed are not supported at this level of SAN Volume Controller Software.
While these levels are not mandatory levels for a customer to be supported by IBM, they are the recommended levels. There may be known operational issues with older firmware and BIOS levels and, in these cases, a customer working with the IBM Support Centre may be directed to upgrade a component to a recommended level.
Note:
* The levels shown in italic text indicate previously recommended levels.
* The level shown in bold text indicates the latest recommended level. | | | | | | Content | Whilst IBM recommends these levels based upon the most recent testing,
the following levels were tested against previous versions of SVC and IBM
will support the use of these levels with SVC V4.2.x: V4.1.x - Supported Hardware List, Device Driver and Firmware Levels for SAN Volume Controller V3.1.0 - Supported Hardware List, Device Driver and Firmware Levels for SAN Volume Controller V2.1.0 - Supported Hardware List, Device Driver and Firmware Levels for SAN Volume Controller Hosts Windows NT 4 Server Host Bus Adapter | HBA Driver | HBA Firmware | Platform | | | | QLA2310/F
QLA2310/FL | | | | FC-2 133 P/N 24P0960 | QLA2340 QLA2340L | | FC2-133 Dual Port P/N 24P8053 | QLA2342 QLA2342L | Windows 2000 and Windows 2003 Server (not using MPIO) Host Bus Adapter | HBA Driver | HBA Firmware | Platform | Notes | | | N/A | QLA2200F | | | | | FC-2 P/N 19K1246 | QLA2310/F
QLA2310/FL | | | | FC-2 133 P/N 24P0960 | QLA2340
QLA2340L
QLA2342
QLA2342L | FC2-133 Dual Port P/N 24P8053 | N/A | QLA2460 QLA2462 | | | | | LP8000 | LP9002L
LP9002DC | LP9402DC | LP9802
LP9802DC | | LP10000 LP10000DC | LP1050 LP1050DC | Windows 2003 Server (Using MPIO) Host Bus Adapter | HBA Driver | HBA Firmware | Platform | Notes | | | FC-2 P/N 19K1246 | QLA2310/F
QLA2310/FL | | | | Requires the following fixes: KB883646 KB824354 KB891793 (which are included in SP1) Requires Multipathing Driver SDDDSM (see Recommended Software Levels) | FC-2 133 P/N 24P0960 | QLA2340 QLA2340L | FC2-133 Dual Port P/N 24P8053 | QLA2342 QLA2342L | P/N 39M5894 | QLA2460 | | P/N 39M5895 | QLA2462 |  | QLe2460 |  | QLe2462 | Emulex | LP9002L LP9002DC | Storport Driver 1.30a9 2.00a12 | | LP9402DC | LP9802 LP9802DC LP1050 LP1050DC | | LP10000 LP10000DC | LP11000 | | LP11002 | LP1150 | LPe11000 | | LPe11002 | LPe1150 | Windows 2008 Server (Using MPIO) Host Bus Adapter | HBA Driver | HBA Firmware | Platform | Notes | QLogic | QLA2340
QLA2340L
QLA2342
QLA2342L | STOR Miniport 9.1.4.15
9.1.7.16 | BIOS 1.54 | | Windows 2008 x64 ( 64bit ) with SVC and SDDDSM is supported in test mode only on V4.2.1.6 and earlier V4.2.1.7 includes full support of Windows 2008 Hyper-V is not supported | QLA2460
QLA2462
QLe2460
QLe2462 | | Emulex | LP9802DC LP1050, LP1050DC LP1050Ex, LP1050ExDC LP10000, LP10000DC LP10000ExDC LP1005DC-CM2 | Storport Driver 2.00a12 | 1.92a1 | LP11000, LP1102 LP1150 | | LPe11000, LPe1102 LPe1150 | | Red Hat EL Advanced Server 2.1 U7 Host Bus Adapter | HBA Driver | HBA Firmware | Platform | Notes | | | FC-2 P/N 19K1246 | QLA2310/F
QLA2310/FL | | | | | FC-2 133 P/N 24P0960 | QLA2340 QLA2340L | FC2-133 Dual Port P/N 24P8053 | QLA2342 QLA2342L | Red Hat EL Advanced Server 3.0 U8 Host Bus Adapter | HBA Driver | HBA Firmware | Platform | Notes | | | FC-2 P/N 19K1246 | QLA2310/F
QLA2310/FL | | | | | FC-2 133 P/N 24P0960 | QLA2340 QLA2340L | FC2-133 Dual Port P/N 24P8053 | QLA2342 QLA2342L | | | | LP9002L LP9002DC | LP9402DC | | | | FC-6228 | FC-6239 | | FC-5716 | | | Red Hat EL Advanced Server 4.0 Host Bus Adapter | HBA Driver | HBA Firmware | Platform | Notes | | | FC-2 P/N 19K1246 | QLA2310/F
QLA2310/FL | | | |  | FC-2 133 P/N 24P0960 | QLA2340 QLA2340L | FC2-133 Dual Port P/N 24P8053 | QLA2342 QLA2342L |  | QLA2460 QLA2462 | | QLe2460 QLe2462 | | | | | LP9002 | LP9802 | | LP10000 LP10000DC | | LP11000 | | LP11002 | LP1150 | LPe11000 | LPe11002 | LPe1150 | IBM | | | | FC5716 / FC1977 | FC3319 SX/LX FC 3320 SX/LX Ficon Express 4, 10km LX: #3321
Ficon Express 4, SX: #3322
Ficon Express 4, 4km LX: #3324 | zfcp |  | | Requires a minimum RHEL 4 kernel level of zLinux RHEL4U4, 2.6.9-42.EL.m3 Supported Machines: System z z800 - IBM 2066 System z z800 - IBM 2086 System z z900 - IBM 2064 System z z990 - IBM 2084 System z z10 2097-E12 System z z10 2097-E26 System z z10 2097-E40 System z z10 2097-E56 System z z10 2097-E64 | Red Hat EL Advanced Server 5 Host Bus Adapter | HBA Driver | HBA Firmware | Platform | Notes | QLogic | | | |  | QLA2460 | QLA2462 | QLe2460 | QLe2462 | QLA2460 | 8.01.07-K7 | | Itanium2 ( IA64) | QLA2460 | Emulex | | | | LP10000 LP10000DC | LP11000 | LPe11000 | LPe11002 | LP11002 | LP1150 | LP10000 LP10000DC | | | LP11000 | | LP11002 | LP11000 | | | Itanium2 ( IA64) | LP11002 | FC3319 SX/LX FC 3320 SX/LX Ficon Express 4, 10km LX: #3321
Ficon Express 4, SX: #3322
Ficon Express 4, 4km LX: #3324 | zfcp |  | | Requires a minimum RHEL 4 kernel level of zLinux RHEL4U4, 2.6.9-42.EL.m3 Supported Machines: System z z800 - IBM 2066 System z z800 - IBM 2086 System z z900 - IBM 2064 System z z990 - IBM 2084 System z z10 2097-E12 System z z10 2097-E26 System z z10 2097-E40 System z z10 2097-E56 System z z10 2097-E64 | SLES 8 United Linux 1.0 SP4 Host Bus Adapter | HBA Driver | HBA Firmware | Platform | Notes | | | FC-2 P/N 19K1246 | QLA2310F QLA2310FL | | | |  | FC-2 133 P/N 24P0960 | QLA2340 QLA2340L | FC2-133 Dual Port P/N 24P8053 | QLA2342 QLA2342L | IBM | | | |  | FC6228 | FC 2319 LX FC 2320 SX | zfcp Native zVM driver |  | | Requires a minimum SLES 8 kernel of 2.4.21-295 with fix for IBM bugzilla 16690. Supported Machines: System z z800 - IBM 2066 System z z890 - IBM 2086 System z z900 - IBM 2064 System z z990 - IBM 2084 | SLES 9 Novell/SuSE Host Bus Adapter | HBA Driver | HBA Firmware | Platform | Notes | | | FC-2 P/N 19K1246 | QLA2310F QLA2310FL | | | |  | FC-2 133 P/N 24P0960 | QLA2340 QLA2340L | | FC2-133 Dual Port P/N 24P8053 | QLA2342 QLA2342L | P/N 39M5894 | QLA2460 | | EM64T, Opteron, Xeon (64 bit) | P/N 39M5895 | QLA2462 |  | QLe2460 |  | QLe2462 | | | | LP9002 | LP9802 | | LP10000 LP10000DC | LP11000 | 2.72a2 | LP11002 | LP1150 | LPe11000 | LPe11002 | LPe1150 | IBM |  |  |  |  |  | FC5716 / FC1977 |  | | |  |  | FC 2315 LX / SX FC 2318 LX / SX FC 2319 LX / SX FC 2320 LX / SX FC 3319 LX / SX FC 3320 LX / SX Ficon Express 4, 10km LX: #3321
Ficon Express 4, SX: #3322
Ficon Express 4, 4km LX: #332 | zfcp |  | | Requires a minimum SLES 9 SP3 kernel of 2.6.5-7.243-S390. Supported Machines: System z z800 - IBM 2066 System z z800 - IBM 2086 System z z900 - IBM 2064 System z z990 - IBM 2084 System z z9-109 System z z10 2097-E12 System z z10 2097-E26 System z z10 2097-E40 System z z10 2097-E56 System z z10 2097-E64 | SLES 10 Novell/SuSE | HBA Driver | HBA Firmware | Platform | Notes | | | | IA32EM64T, Opteron, Xeon
(64 bit) | Vdisk expansion & contraction is not supported | LP9802 | LP10000 LP10000DC | LP11002 | | LPe11000 | LPe11002 | LP11000 | | | | LP11002 | IBM | | | | FC5716 | FC1977 | FC5758 | FC1905 | | FC5759 | FC1910 | | | Supplied with driver | IA32EM64T, Opteron, Xeon
(64 bit) | QLA2460 | QLA2462 | QLA2340 | QLA2342 | FC 2315 LX / SX FC 2318 LX / SX FC 2319 LX / SX FC 2320 LX / SX FC 3319 LX / SX FC 3320 LX / SX Ficon Express 4, 10km LX: #3321
Ficon Express 4, SX: #3322
Ficon Express 4, 4km LX: #332 | zfcp |  | | System z z800 - IBM 2066 System z z800 - IBM 2086 System z z900 - IBM 2064 System z z990 - IBM 2084 System z z9-109 System z z10 2097-E12 System z z10 2097-E26 System z z10 2097-E40 System z z10 2097-E56 System z z10 2097-E64 | Novell OES2/Xen Host Bus Adapter | HBA Driver | HBA Firmware | Platform | Notes | Emulex | | | IA32EM64T, Opteron, Xeon (64 bit) | Vdisk expansion & contraction is not supported | LPe11002 | IBM AIX on System p IBM AIX 4.3.3 IBM AIX 5.1  | Host Bus Adapter | HBA Driver | HBA Firmware | Platform | | FC6227 | Driver included in Technology Level. Please see Recommended Software Levels for latest support | | | FC6228 | | FC6239 | | IBM AIX 5.2  | Host Bus Adapter | HBA Driver | HBA Firmware | Platform | | FC6227 | Driver included in Technology Level. Please see Recommended Software Levels for latest support | | | | | FC6239 | | | | FC5758 / FC1905 | | FC5759 / FC1910 | | FC5773 / FC5774 | | | IBM AIX 5.3  | Host Bus Adapter | HBA Driver | HBA Firmware | Platform | | FC6227 | Driver included in Technology Level. Please see Recommended Software Levels for latest support | | | | | FC6239 | | | | FC5758 / FC1905 | | FC5759 / FC1910 | | FC5773 / FC5774 | | | IBM AIX 6.1  | Host Bus Adapter | HBA Driver | HBA Firmware | Platform | | | Driver included in Technology Level. Please see Recommended Software Levels for latest support | | | FC5758 / FC1905 | | FC5759 / FC1910 | | FC5773 / FC5774 | | | IBM AIX on System i IBM AIX 5L Version 5.2 on System i AIX LPAR IBM AIX 5L Version 5.3 on System i AIX LPAR HP-UX 11.0 for PA-RISC (64-bit only) Host Bus Adapter | HBA Driver | Platform | A6795A | B.11.00.10 | HP 9000 Series Servers (PA-RISC 64-bit only) | A5158A | HP-UX 11i v1 for PA-RISC (64-bit only) Host Bus Adapter | HBA Driver | Platform | A5158A | B.11.11.12 B.11.11.0806 B.11.11.0812 | HP 9000 Series Servers (PA-RISC 64bit only) | A6795A | A6826A | B.11.11.13 B.11.11.17 | A9782A | A9784A | AB378A | AB379A | AB378B | AB379B | AB465A | AD193A | AD194A | HP-UX 11i v2 (B.11.23) for PA RISC and Itanium Host Bus Adapter | HBA Driver | Platform | A5158A | B.11.23.0512 B.11.23.0812 | HP 9000 Series Servers (PA-RISC 64bit) & HP Itanium Servers | A6795A | A6826A | B.11.23.0802 B.11.23.0803 B.11.23.0806 | A9782A | A9784A | AB378A | AB379A | AB378B | AB379B | AB465A | AD193A | AD194A | AD300A | HP Itanium Servers only | HP-UX 11i v3 (B.11.31) for PA RISC and Itanium Host Bus Adapter | HBA Driver | Platform | Notes | A6795A A5158A | FibreChannel-00 B.11.31.0803 | HP 9000 Series Servers (PA-RISC 64bit) & HP Itanium Servers | Minimum SVC level V4.2.1.4 | AB378A AB378B AB379A AB379B AB465A AD193A AD194A A9782A A9784A A6826A | FibreChannel-01 B.11.31.0803 | AD300A | HP Itanium Servers Only | SunOS 5.8/Solaris 8 (32 and 64 bit Sparc) | Host Bus Adapter | HBA Driver | FCode | Multipathing | San Boot | Clustering | Platform | Note | AMCC / JNI | FCE-1473 | 5.3.1.3 | | | No | No | Sun Sparc | | FCE-6460 | FCX / FCX2-6562 | QLogic | QLA2200 | 4.15.05 | | QLA2310 QLA2340 QLA2340L QLA2342 QLA2342L | | | Sun-Badged QLogic | X6799A X6727A | v20060630-21 | 2.1.144 | SG-XPCI2FC-QF2 SG-XPCI1FC-QF2 SG-XPCI2FC-QF2-Z SG-XPCI1FC-QL2 SG-XPCI1FC-QF4 SG-XPCI2FC-QF4 SG-XPCIE1FC-QF4 SG-XPCIE2FC-QF4 | v20070604-2.21
| FCode in Driver Package | Veritas DMP
4.1 | SFHA 4.1 (requires latest ASL available from Symantec) | Sun | SG-XPCI1FC-JF2 | v20040825-1.40 (0) | FCode in Driver Package | | No | SG-XPCI2FC-JF2 | Emulex | LP8000 LP9000 | | | LP9002 LP9802 LP10000 | | Sun Badged Emulex
(emlxs driver)
Emulex
(emlxs driver) | SG-XPCIE1FC-EM4 SG-XPCIE2FC-EM4 SG-XPCI1FC-EM4-Z SG-XPCI2FC-EM4-Z SG-XPCI1FC-EM2-Z SG-XPCI2FC-EM2-Z | v20070604-2.20k | FCode in Driver Package | Veritas DMP 4.1 | SFHA 4.1 (requires latest ASL available from Symantec | SunOS 5.9/Solaris 9 (32 and 64 bit Sparc) | Host Bus Adapter | HBA Driver | FCode | Multipathing | San Boot | Clustering | Platform | Note | AMCC / JNI | FCE-1473 | 5.3.1.3 | | | No | No | Sun Sparc | Solaris
8 and 9  | FCE-6460 | FCX / FCX2-6562 | QLogic | QLA2200 | 4.15.05 | | QLA2310
QLA2340
QLA2340L
QLA2342
QLA2342L | | | Sun-Badged QLogic | X6799A
X6727A | v20060630-21 | 2.1.144 | SG-XPCI2FC-QF2
SG-XPCI1FC-QF2
SG-XPCI2FC-QF2-Z
SG-XPCI1FC-QL2
SG-XPCI1FC-QF4
SG-XPCI2FC-QF4
SG-XPCIE1FC-QF4
SG-XPCIE2FC-QF4 QLA2310
QLA2340
QLA2340L
QLA2342
QLA2342L | v20070604-2.21
| FCode in Driver Package | | SFHA 4.1 (requires latest ASL available from Symantec) | | SFHA/SFRAC 5.0 MP1 (requires latest ASL available from Symantec) | Solaris 9 only | | Yes | SUN Cluster
3.1 & 3.2
SVC Supports up to 4 nodes per cluster | Sun | SG-XPCI1FC-JF2 | v20040825-1.40 (0) | FCode in Driver Package | | No | No | Solaris
8 and 9 | SG-XPCI2FC-JF2 | Emulex | LP8000
LP9000 | | | LP9002
LP9802
LP10000 | | Sun Badged Emulex
(emlxs driver)
Emulex
(emlxs driver) | SG-XPCIE1FC-EM4
SG-XPCIE2FC-EM4
SG-XPCI1FC-EM4-Z
SG-XPCI2FC-EM4-Z
SG-XPCI1FC-EM2-Z
SG-XPCI2FC-EM2-Z LP9002
LP9802
LP10000 | v20070604-2.20k | FCode in Driver Package | |
No
| SFHA 4.1 (requires latest ASL available from Symantec | | SFHA/SFRAC 5.0 MP1 | Solaris 9 only | | Yes | SUN Cluster
3.1 & 3.2
SVC Supports up to 4 nodes per cluster | SunOS 5.10/Solaris 10 (64 bit) Host Bus Adapter Vendor | Host Bus Adapter | HBA Driver | FCode | Multipathing | San Boot | Clustering | Platform | | QLA2200 | 4.15.05 | | | No | No | Sparc | QLA2310
QLA2340
QLA2340L
QLA2342
QLA2342L | | | QLA2460
QLA2462
QLE2460
QLE2462 | | | Sun-Badged QLogic
(qlc driver)
Qlogic
(qlc driver) | SG-XPCI1FC-QF4
SG-XPCI2FC-QF4
SG-XPCIE1FC-QF4
SG-XPCIE2FC-QF4
SG-XPCI2FC-QF2
SG-XPCI1FC-QF2
QLA2342
QLA2340
QLA2460
QLA2462
QLE2460 | Part of OS | FCode in Driver Package | | SPARC: Yes
( requires kernel patch 118833-36 and qlc driver 119130-33 + 125166-05)
x86: No | SFHA 4.1 (requires latest ASL available from Symantec) | | SFHA/SFRAC
5.0 MP1 | Sparc &
x86 | | Yes | SUN Cluster
3.1
SVC Supports up to 4 nodes per cluster | Sparc | SUN Cluster
3.2
SVC Supports up to 4 nodes per cluster | Sparc &
x86 | X6799A
X6727A | v20060630-21 | 2.1.144 | | No | No | Sparc | MPxIO | SUN Cluster 3.1
SVC Supports up to 4 nodes per cluster | | LP8000
LP9000
LP9002 | | | | No | LP9802
LP10000 | | LP11000
LP11002 | | Sun Badged Emulex
(emlxs driver)
Emulex
(emlxs driver) | SG-XPCIE1FC-EM4
SG-XPCIE2FC-EM4
SG-XPCI1FC-EM4-Z
SG-XPCI2FC-EM4-Z
SG-XPCI1FC-EM2-Z
SG-XPCI2FC-EM2-Z
LP11000
LP11002
LPe11000
LPe11002 | Part of OS | FCode in Driver Package | |
Yes
| SUN Cluster 3.1
SVC Supports up to 4 nodes per cluster | Sparc | SUN Cluster 3.2
SVC Supports up to 4 nodes per cluster | Sparc &
x86 | | Yes | SFHA 4.1 (requires latest ASL available from Symantec | Sparc | | Sparc: Yes
x86: No | SFHA/SFRAC 5.0 MP1 | Sparc &
x86 | Novell Netware 6.5  | Host Bus Adapter | HBA Driver | HBA Firmware | Platform | QLogic | QLA2310/F
QLA2310/FL | | | | QLA2340 QLA2340L | QLA2342 QLA2342L | QLA2462 | VMware VMware 2.5  | Host Bus Adapter | ESX | Note | Platform | QLogic | QLA2340 QLA2340L | | Guest OS - Windows 2000 and 2003 ( Clustered & Non Clustered) RH2.1, RH3.0, SLES8, SLES9 | | QLA2342 QLA2342L | QLA2340 QLA2340L | | Guest OS - Windows 2000 and 2003 ( Clustered & Non Clustered) RH2.1, RH3.0, SLES8, SLES9 | QLA2342 QLA2342L | QLA2340 QLA2340L | | Guest OS - Novell Netware only Only supported in single path mode, please visit Software Restrictions for further details. | QLA2342 QLA2342L | Emulex | LP9002 | | Guest OS - Windows 2000 and 2003 ( Clustered & Non Clustered) RH2.1, RH3.0, SLES8, SLES9 | | LP9402 | LP9802 | LP10000 LP10000DC | SAN Boot not supported | VMware 3.01 Note | Customers who are running the VMware 3.01 build are required to move to a minimum VMware level of 3.02 for continued support. | VMware 3.02 ESX | Host Bus Adapter
Model | Host Bus
Adapter
Vendor Support | OS | Note | Additional Information | 3.02 | | Qlogic & Emulex | Windows 2003
Windows 2000 Server SP4 | 
(Standard, Web, Enterprise Editions, and R2), including Service Packs (SP1 and SP2) as noted in VMware Guest Operating System Guide | | Windows NT4 SP6a | | Windows XP Pro SP2 | select only the LSI virtual driver when configuring this guest | Red Hat 2.1 ES/AS/WS Update 6 & 7 |  | Red Hat 3.0 Update 6,7 & 8 | RHEL4 U3 and U4 | | RHEL4 U5 | | RHEL5 | select only the LSI virtual driver when configuring this guest | RHEL Desktop 5 | select only the LSI virtual driver when configuring this guest | SLES 8 SP4 |  | SLES 9 SP 3 | | SLES10 SP1 | | Novell NetWare 6.5 |  | VMware 3.5, 3.51, 3.52, 3.53 & 3.54 ESX | Host Bus Adapter | OS | Note | Additional information | | | Windows 2003 32 & 64Bit
Windows 2000 Server SP4 | 
(Standard, Web, Enterprise Editions, and R2), including Service Packs (SP1 and SP2) as noted in VMware Guest Operating System Guide | | Windows NT4 SP6a | As specified in VMware Guest Operating System Guide | Windows XP Pro SP2 | select only the LSI virtual driver when configuring this guest | Windows Vista | select only the LSI virtual driver when configuring this guest | Red Hat 2.1 ES/AS/WS Update 6 & 7 |  | Red Hat 3.0 Update 6,7 & 8 32 & 64Bit |  | RHEL4 U3 and U4 32 & 64Bit |  | RHEL4 U5 32 & 64Bit | | RHEL5 32 & 64Bit | select only the LSI virtual driver when configuring this guest | RHEL Desktop 5 32 & 64Bit | select only the LSI virtual driver when configuring this guest | SLES 8 SP4 |  | SLES 9 SP 3 32 & 64Bit | | SLES10 SP1 32 & 64Bit |  | Novell Netware 6.5 |  | Tru64 5.1A / 5.1B-2 PK 4 / 5.1B-3/5.1B-4 Host Bus Adapter | HBA Firmware | Platform | Notes | KGPSA-DA (FCA2354) | 3.92A | AlphaServer | Driver Supplied with Operating System | KGPSA-EA (FCA2384) | 1.90A4 | FCA2684 | OpenVMS OpenVMS 7.3-2 Host Bus Adapter | HBA Firmware | Platform | Notes | KGPSA-DA (FCA2354) | 3.92a2 | AlphaServer | Driver Supplied with Operating System | KGPSA-EA (FCA2384) | 1.90a4 | FCA2684 | OpenVMS 8.2 & 8.3 Host Bus Adapter | HBA Firmware | Platform | Notes | KGPSA-CA | 3.92a1 | AlphaServer & Itanium Integrity Servers | Driver Supplied with Operating System | KGPSA-DA (FCA2354) | 3.92a2 | KGPSA-EA (FCA2384) | 1.90a4 | FCA2684 | IBM N Series Gateway and NetApp NetApp & IBM N Series Gateways | NetApp & N Series Gateway support is available on SVC 4.2.1.x via iFix
for selected configurations by RPQ only.
Please contact your IBM representative or authorized IBM Business Partner to request support | SGI Platform | Host Bus Adapter | Firmware | Driver | Notes | Origin | QLA234x | 3.3.6 | Supplied with OS | | Altix | QLA234x |  | Apple Mac OS X Server 10.5.4 Host Bus Adapter | HBA Driver | HBA Firmware | Fcode/BIOS Version | Platform | | 3.2.4 3.27MP | 3.2.4 3.27MP | 13th November 2007 | Apple Xserve intel-based Server | FC-41ES | FC-42ES | FC-44ES | | Support for BladeServer Configurations | SVC supports Server Blades that meet all of the following criteria; 1. The Server blade contains Qlogic and Emulex generic chip sets running the IBM or equivalent supported Drivers; and 2. These generic chip sets and drivers are present in the SVC support matrix for HBAs used in non Blade servers; and 3. The Server blade is running an OS that is present in the SVC support matrix; and 4. Either a Fibre Channel pass through module is used in the Blade server chassis to connect the Blades to an external FC network; or
The Fibre Channel switch module used in the Blade server chassis is equivalent (in the sense it runs the same microcode on the same switch hardware base) to a discrete Fibre Channel switch that is already listed in the SVC support matrix. | Examples of specific BladeCentre configurations that IBM includes in SVC interoperability testing currently include: IBM BladeCenter HS20 / HS21 / HS40 / LS20 / LS21 / LS41 Blade Operating System | HBA | HBA Driver | HBA BIOS | Notes | Windows 2000
(32 bit only) | Qlogic QLA2342 | | | | Windows 2003
(32 bit only) | |  | Windows 2003
(32 and 64 bit) | |  | Qlogic QLA2462s QMC2462 QMC2462s QMI2472 QMI3472 | | |  | IBM 39Y9306 41Y8527 26R0890 26R0884 |  |  | IBM 39Y9186 43W6859 | |  |  | Emulex LP1105 | |  | Windows 2008
(32 and 64 bit) | Qlogic QLA2462s QMC2462 QMC2462s QMI2472 QMI3472 | | | Minimum SVC level for Windows 2008 is SVC 4.2.1.7 | IBM 39Y9306 41Y8527 26R0890 26R0884 |  | IBM 39Y9186 43W6859 | |  | Emulex LP1105 | | Red Hat EL Advanced Server 2.1 | Qlogic QLA2342 | | | (Do not select 7.xx.xx-fo option for Linux; failover enablement is not required with SDD) | Red Hat EL Advanced Server 3.0 | Qlogic QLA2342 | | | Qlogic QLA2462s QMC2462 QMC2462s QMI2472 QMI3472 | | IBM 39Y9306 41Y8527 26R0890 26R0884 | Red Hat EL Advanced Server 4.0
(32 and 64 bit) | Qlogic QLA2342 | | | Qlogic QLA2462s QMC2462 QMC2462s QMI2472 QMI3472 | | IBM 39Y9306 41Y8527 26R0890 26R0884 | IBM 39Y9186 43W6859 | |  | Emulex LP1105 | | Red Hat EL Advanced Server 5.0
(32 and 64 bit) | Qlogic QLA2342 | | | Qlogic QLA2462s QMC2462 QMC2462s QMI2472 QMI3472 | | IBM 39Y9306 41Y8527 26R0890 26R0884 | IBM 39Y9186 43W6859 | |  | Emulex LP1105 | | SLES 8 | Qlogic QLA2342 | | | SLES 9
(32 and 64 bit) | Qlogic QLA2342 | | | Qlogic QLA2462s QMC2462 QMC2462s QMI2472 QMI3472 | | IBM 39Y9306 41Y8527 26R0890 26R0884 | IBM 39Y9186 43W6859 | |  | Emulex LP1105 | | SLES 10 SP1 | Qlogic QLA2342 | | | Qlogic QLA2462s QMC2462 QMC2462s QMI2472 QMI3472 | | IBM 39Y9306 41Y8527 26R0890 26R0884 | IBM 39Y9186 43W6859 | |  | Emulex LP1105 | | VMware | | JS20 JS20 (8842) Drivers Blade Operating System | Kernel & maintenance levels | HBA Driver | Notes | AIX 5.2 | | | | AIX 5.3 | Red Hat EL Advanced Server 4.0 | | | SLES 8 | | JS21 Blade Operating System | Kernel & maintenance levels | HBA Driver | Notes | AIX 5.1 | | | | AIX 5.2 | AIX 5.3 | SLES8 | | | SLES9 | | SLES10 | | JS22 Blade Operating System | Kernel & maintenance levels | HBA | HBA Driver | Notes | AIX 5.3 | | LP1105-BCv | devices.pci.df1023fd.diag 5.3.7.0
devices.pci.df1023fd.rte 5.3.7.0 | | AIX 6.1 | devices.pci.df1023fd.diag 6.1.0.0 devices.pci.df1023fd.rte 6.1.0.0 | SLES10 | QMI3472 | 8.01.10.9 | | RHEL4.6 | 2.6.9-67.EL | QMI3472 | | | RHEL5.1 | 2.6.18-53.el5 | QMI3472 | | HP BladeSystem Support HP BladeSystem Model | HBA Support | Device Drivers | Supported Operating Systems | Notes | BL30p BL40p BL25p BL35p BL460c BL465c BL480c BL685c | 300874-B21 354054-B21 361426-B21 381881-B21 394588-B21 403619-B21 | | Windows 2000 Server Windows Server 2003 VMware RHEL5 | | iSCSI Host Attachment iSCSI hosts are supported with SVC in a non-failover configuration. Due to the technology, we cannot guarantee that the multipathing support available in iSCSI configurations will provide failover and path recovery functions to deal with scenarios where the SAN fabric paths change or fail. This means the concurrent upgrade to SVC is likely to cause errors on an iSCSI host with multipathing enabled. If multipathing is not configured in the iSCSI driver, the user must configure the SAN such that there is only a single path from SVC to the host. This can be acheived by zoning a single SVC port from each IO group to the iSCSI host. In this configuration, an SVC upgrade will be disruptive to the host. Controllers An SVC configuration must include at least one storage controller which supports SVC quorum disks. Please refer to the Configuration Guide which details the recommended customer configurable settings that should be applied for each storage controller type. IBM DS3000 Controller Model | Firmware | NVSRAM | ESM | Supports SVC Quorum Disks | Host Attachment | Notes | | 06.70.22.XX 06.70.24.XX 06.70.69.XX | N1726D340R270V05 | 0186 or higher | | FC | Concurrent download of ESM code, Drive firmware, Controller firmware and NVSRAM with I/O is not supported. Do not reboot both controllers simultaneously. SVC Supports SAS Drive configuration only (i.e. Not SATA drives). Single Controller configuration is not supported. RAID-5 Array size must be 4+1 or larger. Ensure Host type is set to "IBM TS SAN VCE". DS3400 maximum LUNs per partition is currently 32, limiting the number of LUNs from a single DS3400 to a single SVC cluster to 32 RAID-6 Array size must be 4+1+1 or larger. Using Native Copy Services with SVC V3.1.0.4 and later | IBM DS4000 Controller Model | Firmware Release | Storage Manager | Supports SVC Quorum Disks | ESM Support | Notes | | 06.12.56.xx | Download the recommended version of the Storage Manager from the DS4000 website | | Concurrent download of ESM firmware with I/O is not supported | | | 06.23.05.xx 06.60.02.xx 06.60.08.xx 06.60.17.xx 07.10.23.xx 07.15.07.xx 07.36.14.xx 07.36.17.xx | | 06.12.56.xx | | 06.12.56.xx 06.23.05.xx 06.60.02.xx 06.60.08.xx 06.60.17.xx | | | 06.12.56.xx 06.23.05.xx 06.60.02.xx 06.60.08.xx 06.60.17.xx | | 06.12.56.xx 06.23.05.xx 06.60.02.xx 06.60.08.xx 06.60.17.xx | | 06.23.05.xx 06.60.02.xx 06.60.08.xx 06.60.17.xx 07.10.23.xx 07.15.07.xx 07.15.07.xx 07.36.14.xx 07.36.17.xx | | 06.23.05.xx 06.60.02.xx 06.60.08.xx 06.60.17.xx 07.10.23.xx 07.15.07.xx 07.36.14.xx 07.36.17.xx | FAStT (The IBM TotalStorage FAStT Family has been renamed the IBM TotalStorage DS4000 Series) Controller Model | Firmware Release | Storage Manager | Supports SVC Quorum Disks | Notes | FAStT200 | 05.30.25.xx | Download the recommended version of the Storage Manager from the DS4000 website | | Dynamic expansion of controller LUNs is not supported Concurrent download of ESM firmware with I/O is not supported DS4000 copy services (FlashCopy, VolumeCopy, MetroMirror) can be used with SVC. Refer to the following hint & tip for more information: Using Native Copy Services with SVC V3.1.0.4 and later Please refer the DS4000 website for the latest recommended DS4000 client software and RDAC levels | FAStT500 | 05.30.25.xx | DS4000 (FAStT) Expansion Units Expansion Units | Notes | Please refer to the DS4000 website for information on supported expansion units for your specific controller type | Please refer to DS4000 documentation on the DS4000 website for specific procedures and limitations | IBM DS5000 Controller Model | Firmware Release | Storage Manager | Supports SVC Quorum Disks | ESM Support | Notes | DS5100 | 07.30.21.xx 07.36.14.xx 07.36.17.xx 07.50.12.xx | Download the recommended version of the Storage Manager from the DS5000 website | | | Dynamic expansion of controller LUNs is not supported Please refer to the DS5000 website for the latest recommended DS5000 client software and RDAC levels Please refer to the DS5000 website for specific configuration guidelines, cabling requirements & restrictions when attaching EXP5000 and EXP810 DS5000 copy services (FlashCopy, VolumeCopy, MetroMirror) can be used with SVC. Refer to the following hint & tip for more information: DS5000 range maximum LUNs per partition is currently 256, limiting the number of LUNs from a single DS4000 to a single SVC cluster to 256. RAID-5 Array size must be 4+1 or larger. RAID-6 Array size must be 4+1+1 or larger. Minimum supported SVC code level is 4.2.1.8 | DS5300 | IBM DS6000 Model | Firmware | Supports SVC Quorum Disks | Notes | DS6800 | | | | IBM DS8000 Model | Firmware | Supports SVC Quorum Disks | Notes | DS8100 | | | | DS8300 | | IBM ESS Model | Firmware | Supports SVC Quorum Disks | Notes | 2105-E10 | minimum EC 2.3.3.134 minimum EC 2.3.3.178 | | | 2105-E20 | 2105-F10 | 2105-F20 | 2105-800 | minimum EC 2.4.4.70 minimum EC 2.4.4.112 | 2105-750 | HP Model | Firmware | AKA | Supports SVC Quorum Disks | Notes | MA 8000 | v8.7.F-7 Plus all no-charge upgrades from the vendor | HSG80 | (Note: Not recommended if using only one port) | Your HP support representative will perform hardware maintenance and firmware upgrade procedures. These operations are non-disruptive to SVC Dynamic expansion of controller LUNs is not supported Refer to Configuration Guide which details specific requirements for attachment to SVC | EMA 12000 | EMA 16000 | Model | Firmware | AKA | Supports SVC Quorum Disks | Notes | MSA1000 | 4.48/5.20 |  | | Your HP support representative will perform hardware maintenance and firmware upgrade procedures. These operations are non-disruptive to SVC Active/Active functionality is only supported on SVC level 4.3.0 and above. Dynamic expansion of controller LUNs is not supported Refer to Configuration Guide which details specific requirements for attachment to SVC | MSA1500 | 5.20 | Model | Firmware | AKA | Supports SVC Quorum Disks | Notes | EVA 3000 | VCS 3.110 VCS 4.007 |  | | Your HP support representative will perform hardware maintenance and firmware upgrade procedures. These operations are non-disruptive to SVC Dynamic expansion of controller LUNs is not supported Refer to EVA product documentation for concurrent maintenance procedures Refer to Configuration Guide which details specific requirements for attachment to SVC | EVA 5000 | Model | Firmware | AKA | Supports SVC Quorum Disks | Notes | EVA 4000 | XCS 6.100 |  | | Your HP support representative will perform hardware maintenance and firmware upgrade procedures. These operations are non-disruptive to SVC Dynamic expansion of controller LUNs is not supported Refer to EVA product documentation for concurrent maintenance procedures Refer to Configuration Guide which details specific requirements for attachment to SVC | EVA 6000 | EVA 8000 | EVA 4100 | XCS 6.110 | Your HP support representative will perform hardware maintenance and firmware upgrade procedures. These operations are non-disruptive to SVC Dynamic expansion of controller LUNs is not supported Refer to EVA product documentation for concurrent maintenance procedures Refer to Configuration Guide which details specific requirements for attachment to SVC | EVA 6100 | EVA 8100 | Model | Firmware | AKA | Supports SVC Quorum Disks | Notes | XP48 | 01-19-99-00/04 | HDS 9910 | | Your HP support representative will perform hardware maintenance and firmware upgrade procedures. These operations are non-disruptive to SVC Dynamic expansion of controller LUNs is not supported An SVC configuration must include at least one storage controller which supports SVC quorum disks Refer to Configuration Guide which details specific requirements for attachment to SVC | XP512 | HDS 9960 | XP128 | 21-14-34-00/00 | HDS 9970V | XP1024 | HDS 9980V | XP10000 | 50-09-06-00/00 | HDS NSC55 | XP12000 | HDS USP | Hitachi Data Systems HDS Thunder | Firmware | AKA | Supports SVC Quorum Disks | Notes | 9200 | 055L/F | SANrise 1200 | | Your HDS support representative will perform hardware maintenance and firmware upgrade procedures. These operations are non-disruptive to SVC Dynamic expansion of controller LUNs is not supported Refer to Configuration Guide which details specific requirements for attachment to SVC | 9520V | 065D/B |  | 953xV / 9570V | 065D/B |  | 9580V | 165D/B |  | 9585V | 165D/B |  | HDS Lightning | Firmware | AKA | Supports SVC Quorum Disks | Notes | 9910 | 01-19-99-00/04 | HP XP48 StorEdge 9910 | | Your HDS support representative will perform hardware maintenance and firmware upgrade procedures. These operations are non-disruptive to SVC Dynamic expansion of controller LUNs is not supported An SVC configuration must include at least one storage controller which supports SVC quorum disks Refer to Configuration Guide which details specific requirements for attachment to SVC | 9960 | 01-19-99-00/04 | HP XP512 StorEdge 9960 | 9970V | 21-14-34-00/00 | HP XP128 StorEdge 9970 | 9980V | 21-14-34-00/00 | HP XP1024 StorEdge 9980 | TagmaStore | Firmware | AKA | Supports SVC Quorum Disks | Notes | NSC55 | 50-09-06-00/00 |  | | Your HDS support representative will perform hardware maintenance and firmware upgrade procedures. These operations are non-disruptive to SVC Dynamic expansion of controller LUNs is not supported An SVC configuration must include at least one storage controller which supports SVC quorum disks Refer to Configuration Guide which details specific requirements for attachment to SVC | USP100 | USP600 | USP1100 | AMS & WMS | Firmware | AKA | Supports SVC Quorum Disks | Notes | AMS200 | 0770/G-M |  | | Your HDS support representative will perform hardware maintenance and firmware upgrade procedures. These operations are non-disruptive to SVC Dynamic expansion of controller LUNs is not supported Refer to Configuration Guide which details specific requirements for attachment to SVC | AMS500 | AMS1000 | WMS100 | EMC | Firmware | Supports SVC Quorum Disks | Notes | CX 200 | 02.19.200.5.xxx | | Your EMC support representative will perform hardware maintenance and firmware upgrade procedures. These operations are non-disruptive to SVC
Dynamic expansion of controller LUNs is not supported
Refer to Configuration Guide which details specific requirements for attachment to SVC | CX 400 | 02.19.400.5.xxx | CX 600 | 02.19.600.5.xxx | CX 300 | 02.19.300.5.xxx 02.26.300.5.xxx | CX 500 | 02.19.500.5.xxx 02.26.500.5.xxx | CX 700 | 02.19.700.5.xxx 02.26.700.5.xxx | CX3-10 | 03.26.010.5.xxx | | Dynamic expansion of controller LUNs is not supported
Refer to Configuration Guide which details specific requirements for attachment to SVC | CX3-20 | 03.26.020.5.xxx | CX3-40 | 03.26.040.5.xxx | CX3-80 | 03.26.080.5.xxx | Dynamic expansion of controller LUNs is not supported
Refer to Configuration Guide which details specific requirements for attachment to SVC | FC4700 | 08.51.60 | | Your EMC support representative will perform hardware maintenance and firmware upgrade procedures. Concurrent hardware maintenance operations are non-disruptive to SVC. This product requires I/O to be quiesced during firmware upgrade
Dynamic expansion of controller LUNs is not supported
Refer to Configuration Guide which details specific requirements for attachment to SVC | EMC Symmetrix |  | Supports SVC Quorum Disks | Notes | 8000 Series (8130, 8230, 8430, 8530, 8730, 8830) | Enginuity 5568 | | | DMX & DMX-2 800/1000/2000/3000 | Enginuity 5671 | | DMX-3 | Enginuity 5772 Enginuity 5773 | | DMX-4 | Enginuity 5772 Enginuity 5773 | | Sun StorEdge StorEdge | Firmware | AKA | Supports SVC Quorum Disks | Notes | 9910 | 01-19-99-00/04 | HDS 9910 | | Your Sun support representative will perform hardware maintenance and firmware upgrade procedures. These operations are non-disruptive to SVC Dynamic expansion of controller LUNs is not supported An SVC configuration must include at least one storage controller which supports SVC quorum disks Refer to Configuration Guide which details specific requirements for attachment to SVC | 9960 | 01-19-99-00/04 | HDS 9960 | 9970 | 21-14-34-00/00 | HDS 9970V | 9980 | 21-14-34-00/00 | HDS 9980V | 9990 | 50-09-06-00/00 |  | StorageTek StorageTek D-Series Model | Firmware | NVSRAM | SANTricity | Supports SVC Quorum Disks | Notes | D173 | 5.30.23.00 | N2772-530855-006 | 8.30.G2.05 | |  | D178 | 5.39.01.00 5.40.19.00 6.10.15.00 6.12.10.00 | N4884-530855-005 N4884-540855-005 N4884-610855-006 N4884-612855-003 | 8.30.G2.00 8.40.G2.08 9.10.G2.03 9.15.G2.01 | D220 | 5.34.08.00 | N2882-534855-003 | 8.34.G2.05 | D240 | 5.40.19.00 6.10.15.00 6.12.10.00 | N2882-540855-007 N288X-610855-006 N288X-612855-003 | 8.40.G2.08 9.10.G2.03 9.15.G2.01 | AKA FlexLine 240 | D280 | 5.30.23.00 5.40.19.00 6.10.15.00 6.12.10.00 | N5884-530855-005 N5884-540855-005 N588X-610855-006 N588X-612855-003 | 8.30.G2.05 8.40.G2.08 9.10.G2.03 9.15.G2.01 | AKA FlexLine 280 | StorageTek FlexLine 200 Series Model | Firmware | NVSRAM | SANTricity | Supports SVC Quorum Disks | Notes | FLX210 | 6.12.10.00 | N282X-612855-003 | 9.12.G2.01 | |  | FLX240 | 6.12.10.00 | N288X-612855-003 | AKA D240 | FLX280 | 6.12.10.00 | N588X-612855-003 | AKA D280 | FLX380 | 6.15.12.00 | N6091-614855-004 | 9.15.G2.01 |  | StorageTek 6000 Series Model | Firmware | Supports SVC Quorum Disks | Notes | 6540 | 06.16.81.10 | | Your Sun support representative will perform hardware maintenance and firmware upgrade procedures. These operations are non-disruptive to SVC Dynamic expansion of controller LUNs is not supported An SVC configuration must include at least one storage controller which supports SVC quorum disks Refer to Configuration Guide which details specific requirements for attachment to SVC | 6130 | 6140 | IBM N Series Filer and NetApp FAS IBM N Series | NetApp | Firmware | Supports SVC Quorum Disks | Notes | N/A | 920 | | | Your IBM or NetApp support representative will perform hardware maintenance and firmware upgrade procedures. These operations are non-disruptive to SVC Dynamic expansion of controller LUNs is not supported Refer to Configuration Guide which details specific requirements for attachment to SVC Note: host type should be set to Linux | 940 | 960 | 980 | N3700 2863-A10 2863-A20 | 270 | | N5200 2864-A10 2864-A20 | 3020 | N5300 2869-A10 2869-A20 | 3040 | N5500 2865-A10 2865-A20 | 3050 | N5600 2868-A10 2868-A20 | 3070 | N7600 2866-A10 2866-A20 | 6030 | N7800 2867-A10 2867-A20 | 6070 | Fujitsu Eternus Type | Model | Firmware | Supports SVC Quorum Disks | Notes | 3000 | 100 | V20L86 V20L91 | | Refer to Configuration Guide which details specific requirements for attachment to SVC Dynamic expansion of controller LUNs is not supported | 100D | V30L21 V30L27 | 200 | V20L86 V20L91 | 400 | 600 | 300 | V20L56 V10L61 | 500 | 700 | 300B | V20L56 V20L61 | 500B | 700B | 4000 | 100 | V30L21 V30L27 | 300 | V10L70 V11L33 | 500 | 8000 | 900 | 1100 | 2100 |  |  | Bull Storeway Model | Firmware | Supports SVC Quorum Disks | Notes | FDA1500 | 436 | | | FDA2500 | FDA2900 | 435 | NEC iStorage Model | Firmware | Supports SVC Quorum Disks | Notes | S1500 | 436 | | | S2500 | S2900 | 435 | Switches SVC supports NPIV products in the SAN with the restriction that these products can only be used for host attachment. An example of an NPIV product is the Brocade Access Gateway module for the BladeCenter. For director-class switches, only blades with port speeds of up to 4gbps are supported. FCIP technology listed on the IBM SAN Support pages can be used in SVC configurations for the following uses: 1) iSCSI host attachment. Please refer to the iSCSI Host Attachment section for more information. 2) Links between two SVC clusters in a Metro Mirror or Global Mirror configuration. Please refer to the Configuration Guide for details | All blades comprising of ISWL ports are supported in SVC configurations, provided that they are listed on the IBM SAN Support pages. This includes the Cisco MDS 9000 Family 4-port 10Gbps Fibre Channel Switching Module and the Brocade 10Gbps Fibre Channel blade. | IBM BladeCenter Supported Configurations | For BladeCenter switch module, Passthrough module, switch vendor interconnectivity and supported firmware levels, please visit the IBM BladeCenter support website | Brocade IBM Model | Firmware | Class | AKA | Notes | | 5.3.1a 6.0.0c 6.1.0a 6.1.0b 6.1.0c | Fabric Switch | SAN16B-2 Silkworm 200E EMC DS-16B2 |  | | 5.3.0d 5.3.1a 6.0.0c 6.1.0a 6.1.0b 6.1.0c | Director | SAN256B Silkworm 48000 |  | | 5.3.0d 5.3.1a | Fabric Switch | SAN Switch H08 / 16 Silkworm 3250 / 3850 |  | | 5.3.1a 6.0.0c 6.1.0a 6.1.0b 6.1.0c | Fabric Switch | SAN32B-2 Silkworm 4100 |  | | 5.3.1a 6.0.0c 6.1.0a 6.1.0b 6.1.0c | Fabric Switch | SAN64B-2 Silkworm 4900 |  | | 5.3.0d 5.3.1a | Fabric Switch | SAN Switch F32 Silkworm 3900 EMC DS-32B2 |  | | 5.3.0d 5.3.1a | Director | SAN Switch M14 Silkworm 24000 |  | | 5.0.5e | Director | SAN Switch M12 Silkworm 12000 |  | | 3.2.1c | Fabric Switch | Silkworm 3200 |  | | 3.2.1c | Fabric Switch | SAN Switch F16
Silkworm 3800 |  | | 2.6.2d | Fabric Switch | SAN Switch S08 / S16 Silkworm 2400 / 2800 |  | | 5.2.1_NI1 5.3.1a 6.0.0c 6.1.0a 6.1.0b 6.1.0c | Fabric Switch | Silkworm 5000 SAN32B-3 20055KB |  | | 5.3.1a 6.0.0c 6.1.0a 6.1.0b 6.1.0c | Director | Brocade DCX SAN768B |  | | 6.1.0a 6.1.0b 6.1.0c | Fabric Switch | Brocade 3000 |  | | 6.1.0a 6.1.0b 6.1.0c | Fabric Switch | Brocade 5100 |  | | 6.1.0a 6.1.0b 6.1.0c | Fabric Switch | Brocade 5300 |  | Cisco MDS Model | Firmware | Class | AKA | Notes | | 3.1(3a) 3.2(2c) 3.2(3a) 3.3(1a) 3.3(1c) | Director | 2062-D04 |  | | 2062-D07 | | 2062-E11 | | Fabric Switch | 2062-D1A / D1H | | 2061-040 | | 2061-020 | | 2053-424 | |  | |  | | 2.1(2) |  | 2061-420 |
CNT FC/9000 Model | Firmware | Class | AKA | Notes | 2042-001 / 128 (FCM) | 3.0.5 | Director, 1G |  | Asynchronous replication capabilities for SAN Volume Controller are available from CNT. For more information, please refer to this website: www.cnt.com/products/extension/ura | 2042-001 / 128 / 256 (FCM-E) | 5.0.4 | Director, 2G |  | McDATA IBM Name for IBM Badged Switch | McDATA Model | Firmware | Class | AKA | Notes | IBM# for IBM Badged Switch | IBM# for McDATA Badged Switch | Other |  | | EOSc 09.06.02 09.07.01 09.07.02 09.08.01 | Sphereon Fabric Switch |  | 2031-016 |  |  |  | | Sphereon Fabric Switch |  | 2031-032 | EMC DS-32M2 |  |  | | Sphereon Fabric Switch |  | 2031-216 |  |  | IBM SAN32M-1 | | Sphereon Fabric Switch | 2027-232 | 2031-232 |  |  | IBM SAN24M-1 | | Sphereon Fabric Switch | 2026-224 | 2031-224 |  |  | IBM SAN16M-2 | | Sphereon Fabric Switch | 2026-416 |  |  |  | IBM SAN32M-2 | | Sphereon Fabric Switch | 2026-432 |  |  |  |  | | Intrepid Director |  | 2032-064 | EMC ED-64M |  | IBM SAN140M-1 | | Intrepid Director | 2027-140 | 2032-140 | EMC ED-140M | UPM and QPM Supported | IBM SAN256M | | EOSn 09.06.01 09.06.02 09.06.03 09.07.01 09.07.02 09.08.01 | Intrepid Director | 2027-256 |  |  | 2GB & 4GB LIMs | Qlogic Model | Firmware | Class | AKA | Notes | 5600 | V6.8.0.03 | Fabric Switch |  | Max 64 hosts per I/O Group 128 host N port logins per IO group (64 per node port) | 5602 | 9000 | V6.6.0.15 V6.8.0.03 | Other Hardware Technologies for extending the distance between two SVC clusters can be broadly divided into the following two categories. These extenders are only supported as inter cluster links and not intra cluster links, i.e. they should not be used between SVC nodes that are part of the same cluster. Inter Cluster Fibre Channel Extenders
Fibre channel extenders simply extend a fibre channel link by transmitting fibre channel packets across long links without changing the contents of those packets. IBM has tested a number of such fibre channel extender technologies with SVC and will support fibre channel extenders of all types provided that they are planned, installed and operated as described in the IBM System Storage SAN Volume Controller V4.2.1 - Software Installation and Configuration Guide document. Inter Cluster SAN Routers SAN routers extend the scope of a SAN by providing "virtual nPorts" on two or more SANs. The router arranges that traffic at one virtual nPort is propagated to the other virtual nPort but the two fibre channel fabrics are independent of one another. Thus nPorts on each of the fabrics cannot directly log into each other. Due to the more complex interactions involved, IBM explicitly tests products of this class for interoperability with SAN Volume Controller. The following SAN Routers are supported for use with SVC when planned, installed and operated as described in the IBM System Storage SAN Volume Controller V4.2.1 - Software Installation and Configuration Guide document. Inter Cluster SAN Routers | Firmware | AKA | Notes | IBM# for IBM Badged Switch | SAN04M-R SAN Router | McDATA Eclipse 1620 SAN Router | EOSi 4.07.00 5.01.00 | 2027-R04 | The Advanced Functions Router pairs for HA Configurations & iFCP Fast Failover in EOSi 5.01.00 are not supported at this time | SAN16M-R SAN Router | McDATA Eclipse 2640 SAN Router | 2027-R16 | SAN16B-R SAN Router | Brocade AP7420 SAN Router | 7.4.1d | 2109-A16 |  | SAN18B-R | Silkworm 7500 | 6.0.0c | 2005-R18 |  | SAN04B-R | Silkworm 7500E | 6.1.0a | 2005-R04 |  | M48 FC3450 Blade | Silkworm 48000 director blade FR4-18i | 6.1.0c | N/A |  | Cisco MDS 9000 Series Inter VSAN Routing | 3.1(3a) 3.2(2c) 3.2(3a) |  |  | IBM TotalStorage NAS Gateway 500 TotalStorage NAS Gateway 500 | NAS System Software | Type | Model | | NAS v1.1.1 | 5198 | 001 | | | | | | | | | |
 |
| IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml. |
 |
 |
 |
| Please take a moment to complete this form to help us better serve you. |
 |
 |
 |
|
|
|
 |
 |
| Product categories: |
 |
| | Hardware |  |
| | Computer Storage |  |
| | Storage Virtualization |  |
| | SAN Volume Controller |  |
| | IBM TotalStorage SAN Volume Controller Storage Engine |  |
| | V4.2.x |  |
 |
| Operating system(s): |
| |
SAN Volume Controller
|
 |
| Version: |
| |
V4.2.x
|
 |
| Reference #: |
| |
S1003091
|
 |
| IBM Group: |
| | Storage Systems Group |
 |
| Modified date: |
| | 2009-06-17 |
 |
|