V2.1.0 - Supported Hardware List, Device Driver and Firmware Levels for SAN Volume Controller

Flash (Alert)


Abstract

The documents titled Supported Hardware List and Recommended Software Levels provide the operating systems, host adapters, SAN fabric elements, RAID controllers and selected other hardware that have been tested or qualified by IBM.

For operating systems, we show the latest tested release levels and service packs. Only the listed operating systems are supported. For host adapters, SAN fabric elements and RAID controllers, we list our currently recommended firmware and/or BIOS levels and formally support only the hardware listed.

While these levels are not mandatory levels for a customer to be supported by IBM, they are the recommended levels. There may be known operational issues with older firmware and BIOS levels and, in these cases, a customer working with the IBM Support Centre may be directed to upgrade a component to a recommended level.

Content


IMPORTANT NOTICE: SAN Volume Controller V2.1.0 is no longer supported. Refer to the SAN Volume Controller Support Statement for further information.



HBAs - by Host Operating System:
IBM BladeCenter® HS20 / HS40 / JS20

iSCSI Host Attachment

RAID Controllers
SAN Switches Other Hardware

HBAs - by Host Operating System

Windows NT 4 Server

Host Bus Adapter
HBA Driver
HBA Firmware
Platform
IBM TotalStorage DS4000 (FAStT)
FC-2 P/N 19K1246
QLA2310/F
QLA2310/FL
FC-2 133 P/N 24P0960
QLA2340
QLA2340L
FC2-133 Dual Port P/N 24P8053
QLA2342
QLA2342L


Windows 2000 and Windows 2003 Server (32 bit only)

Host Bus Adapter
HBA Driver
HBA Firmware
Platform
Windows System requirements
IBM TotalStorage DS4000 (FAStT)
N/A
QLA2200F
Intel Based Servers




Including x360, x345, x335, x440
FC-2 P/N 19K1246
QLA2310/F
QLA2310/FL
FC-2 133 P/N 24P0960
QLA2340
QLA2340L
FC2-133 Dual Port P/N 24P8053
QLA2342
QLA2342L
LP8000
LP9002L
LP9002DC
LP9402DC
LP9802
LP9802DC


Windows 2003 Server + MPIO (Requires Storport Driver + SDDDSM)

Host Bus Adapter
HBA Driver
HBA Firmware
Platform
Notes
IBM TotalStorage DS4000 (FAStT)
FC-2 P/N 19K1246
QLA2310/F
QLA2310/FL
Intel Based Servers

Including x360, x345, x335, x440

Storport Driver not supported by BladeCenter Server at this time
Windows 2003 only
with the following fixes:

KB883646
KB824354

Requires SDD Driver SDDDSM package 2.0.0.0-B14 for W2K3
FC-2 133 P/N 24P0960
QLA2340
QLA2340L
FC2-133 Dual Port P/N 24P8053
QLA2342
QLA2342L


Red Hat EL Advanced Server 2.1 U6
Red Hat EL Advanced Server 3.0 U4

Host Bus Adapter
HBA Driver
HBA Firmware
Platform
Notes
IBM TotalStorage DS4000 (FAStT)
FC-2 P/N 19K1246
QLA2310/F
QLA2310/FL
Fabric maintenance and CCL restrictions apply, please visit Software Restrictions for further details
FC-2 133 P/N 24P0960
QLA2340
QLA2340L
FC2-133 Dual Port P/N 24P8053
QLA2342
QLA2342L


SLES 8 United Linux 1.0 SP3

Host Bus Adapter
HBA Driver
HBA Firmware
Platform
Note
IBM TotalStorage DS4000 (FAStT)
FC-2 133 P/N 24P0960
QLA2340
QLA2340L
FC2-133 Dual Port P/N 24P8053
QLA2342
QLA2342L
FC6228
4.22d
Included in SP3
Tested with SLES 8 SP3 kernel 2.4.21-111 only

Fabric maintenance and CCL restrictions apply, please visit Software Restrictions for further details



IBM AIX on pSeries

IBM AIX 4.3.3

Host Bus Adapter
HBA Driver
HBA Firmware
Platform
IBM
devices.pci.df1000f7.rte.4.3.3.76
devices.pci.df1000f7.com 4.3.3.92
devices.fcp.disk.rte 4.3.3.78
3.30X1
devices.pci.df1000f9.rte.4.3.3.76
devices.pci.df1000f7.com 4.3.3.92
devices.fcp.disk.rte 4.3.3.78
3.91A1


IBM AIX 5.1

Host Bus Adapter
HBA Driver
HBA Firmware
Platform
IBM
devices.pci. df1000f7.rte 5.1.0.37
devices.pci.df1000f7.com 5.1.0.64
devices.fcp.disk.rte 5.1.0.60
devices.pci.df1000f9.rte 5.1.0.37
devices.pci.df1000f7.com 5.1.0.64
devices.fcp.disk.rte 5.1.0.60
devices.pci.df1080f9.rte 5.1.0.2
devices.pci.df1000f7.com 5.1.0.64
devices.fcp.disk.rte 5.1.0.60


IBM AIX 5.2

Host Bus Adapter
HBA Driver
HBA Firmware
Platform
IBM
FC5716
devices.pci.df1000fa.rte 5.2.0.50
devices.pci.df1000f7.com 5.2.0.60
devices.fcp.disk.rte 5.2.0.60
devices.scsi.disk.rte 5.2.0.60
devices.pci.df1000f7.rte 5.2.0.30
devices.pci.df1000f7.com 5.2.0.60
devices.fcp.disk.rte 5.2.0.60
devices.scsi.disk.rte 5.2.0.60
devices.pci.df1000f9.rte 5.2.0.30
devices.pci.df1000f7.com 5.2.0.60
devices.fcp.disk.rte 5.2.0.60
devices.scsi.disk.rte 5.2.0.60
devices.pci.df1080f9.rte 5.2.0.30
devices.pci.df1000f7.com 5.2.0.60
devices.fcp.disk.rte 5.2.0.60
devices.scsi.disk.rte 5.2.0.60



IBM AIX 5.3

Host Bus Adapter
HBA Driver
HBA Firmware
Platform
IBM
devices.pci.df1000fa.rte 5.3.0.10
devices.pci.df1000f7.com 5.3.0.22
devices.fcp.disk.rte 5.3.0.21
devices.scsi.disk.rte 5.3.0.21
devices.pci.df1000f7.rte 5.3.0.1
devices.pci.df1000f7.com 5.3.0.22
devices.fcp.disk.rte 5.3.0.21
devices.scsi.disk.rte 5.3.0.21
devices.pci.df1000f9.rte 5.3.0.1
devices.pci.df1000f7.com 5.3.0.22
devices.fcp.disk.rte 5.3.0.21
devices.scsi.disk.rte 5.3.0.21
devices.pci.df1080f9.rte 5.3.0.1
devices.pci.df1000f7.com 5.3.0.22
devices.fcp.disk.rte 5.3.0.21
devices.scsi.disk.rte 5.3.0.21



IBM AIX on iSeries

IBM AIX 5L Version 5.2 on iSeries AIX LPAR

Host Bus Adapter
HBA Driver
HBA Firmware
Platform
IBM
devices.pci.df1000fa.rte 5.2.0.50
devices.pci.df1000f7.com 5.2.0.52
devices.fcp.disk.rte 5.2.0.50
devices.scsi.disk.rte 5.2.0.50
devices.pci.df1000f9.rte 5.2.0.30
devices.pci.df1000f7.com 5.2.0.52
devices.fcp.disk.rte 5.2.0.50
devices.scsi.disk.rte 5.2.0.50
devices.pci.df1080f9.rte 5.2.0.30
devices.pci.df1000f7.com 5.2.0.52
devices.fcp.disk.rte 5.2.0.50
devices.scsi.disk.rte 5.2.0.50


IBM AIX 5L Version 5.3  on iSeries AIX LPAR

Host Bus Adapter
HBA Driver
HBA Firmware
Platform
IBM
devices.pci.df1000fa.rte 5.3.0.1
devices.pci.df1000f7.com 5.3.0.2
devices.fcp.disk.rte 5.3.0.2
devices.scsi.disk.rte 5.3.0.2
devices.pci.df1000f9.rte 5.3.0.0
devices.pci.df1000f7.com 5.3.0.2
devices.fcp.disk.rte 5.3.0.2
devices.scsi.disk.rte 5.3.0.2
devices.pci.df1080f9.rte 5.3.0.0
devices.pci.df1000f7.com 5.3.0.2
devices.fcp.disk.rte 5.3.0.2
devices.scsi.disk.rte 5.3.0.2


HP-UX 11i v1 for PA-RISC (64-bit only)

Host Bus Adapter
HBA Driver
Platform
A6795A
B.11.11.09
HP 9000 Series Servers (PA-RISC 64-bit only)
A5158A


SunOS 5.8/Solaris 8 (64 bit only)
SunOS 5.9/Solaris 9 (64 bit only)

Host Bus Adapter
HBA Driver
FCode
Platform
JNI FCE-1473
Sun Sparc
JNI FCE-6460
JNI AMCC FCX / FCX2-6562
QLA2340
QLA2340L
FCode in Driver Package
QLA2342
QLA2342L
LP9002L
LP9002DC
FCode in Driver Package


Novell Netware 6.5 SP2

Host Bus Adapter
HBA Driver
HBA Firmware
Platform
QLA2310/F
QLA2310/FL
QLA2340
QLA2340L
QLA2342
QLA2342L


VMware

Host Bus Adapter
ESX
Note
Platform
QLA2340
QLA2340L
Guest OS - Windows 2000 and 2003 only
QLA2342
QLA2342L
QLA2340
QLA2340L
Guest OS - Novell Netware only
Only supported in single path mode, please visit Software Restrictions for further details.
QLA2342
QLA2342L


BladeCenter HS20 / HS40 / JS20

HS20 (8678, 8832, 8843) / HS40 (8839) Drivers

Blade Operating System
HBA Driver
HBA BIOS
Notes
Windows 2000 (32 bit only)
Driver and Firmware downloads are available from the Qlogic site under IBM BladeCenter

(Do not select 7.01.01-fo option for Linux; failover enablement is not required with SDD)
Windows 2003 (32 bit only)
Red Hat EL Advanced Server 2.1
Red Hat EL Advanced Server 3.0
SLES 8


JS20 (8842) Drivers

Blade Operating System
HBA Driver
FCode
Comments
AIX 5.2 ML04
devices.pci.77101223.com 5.2.0.51
devices.pci.77101223.rte 5.2.0.50
devices.fcp.disk.rte 5.2.0.50
devices.scsi.disk.rte 5.2.0.50
Red Hat EL Advanced Server 3.0 (U4)
Driver and Firmware downloads are available from the Qlogic site under IBM BladeCenter

(Do not select 7.01.01-fo option for Linux; failover enablement is not required with SDD)
SLES 8


BladeCenter Blades HS20 (8678, 8832, 8843), HS40 (8839) and JS20 (8842) are supported in the following configurations:

Internal Switch Module
Module Firmware
Supported Fabrics
Comments
Notes
Optical PassThrough Module
7
Brocade
McDATA
CNT
Cisco
The BladeCenter Optical Pass Through Module is essentially a connection between Fibre Channel HBAs in the BladeCenter and the external SAN. As the BladeCenter HBAs are functionally equivalent to a QLogic 231x type adapter, this optical pass through mode of attachment may be used with all SVC SAN configurations that support QLogic HBA attachment to the SVC
Some configurations will require the use of interop mode. Information on configuring BladeCenter can be found in the BladeCenter documentation
QLogic 2-port FC Switch
Brocade
McDATA
CNT
Cisco
The BladeCenter HBAs are attached to external devices via either the QLogic or Brocade switch within the BladeCenter. When operating in this configuration the BladeCenter internal switch may only be attached to switches produced by a single vendor
QLogic 6-port FC Switch
Brocade
McDATA
CNT
Cisco
Brocade SAN Switch (2-port)
Brocade

iSCSI Host Attachment

SVC is supported connected to Cisco MDS 9000 Family platform with the following attached iSCSI hosts (in single path mode only):


Operating System
Drivers
Notes
Windows 2000 (32 bit only) (SP4)
Clustering Not Supported
Windows 2003 (32 bit only) (SP1)
Red Hat EL Advanced Server 2.1
Red Hat EL Advanced Server 3.0


Guidelines for zoning iSCSI hosts and SVC

In a conventional Fibre Channel SAN, there will normally be a number of SAN paths between a particular SVC IO group and the server HBA ports that use the vdisks supplied by that IO group. A multipathing device driver is run on the server to resolve these multiple paths into a single logical device that the server can perform I/O to. The multipathing device driver also provides failover and path recovery functions that deal with scenarios where the SAN fabric paths change or fail. The present iSCSI solution however only supports a single path between the iSCSI host NIC and the SVC vdisk and there is no multipathing driver in the iSCSI host. This means that there is no recovery from errors and is not possible to concurrently upgrade the SVC firmware while maintaining connectivity from an iSCSI host system. As such it is inappropriate for the SVC to present the vdisk at multiple ports in the Fibre Channel SAN, and to prevent this, the user must select a single SVC port in each SVC IO group that is to be associated with each iSCSI host. Zoning is then applied in the MDS switch so that each iSCSI host can see only one SVC port in each SVC IO group. If multiple iSCSI hosts are in use, the hosts should be evenly spread across the ports in each SVC IO group. The SVC svctask mkvdiskhostmap command should then used to ensure that each SVC vdisk is mapped to a single NIC in the server.

Please visit the following Cisco link for further information: http://www.cisco.com/en/US/netsol/ns512/netqa0900aecd802a9217.html


RAID Controllers

Please refer to the Configuration Guide which details the recommended customer configurable settings that should be applied for each storage controller type.

IBM DS4000

Controller Model
Firmware Release
Storage Manager
Notes
05.42.10.00
Download the recommended version of the Storage Manager from the DS4000 website
Dynamic expansion of controller LUNs is not supported

Please refer the DS4000 website for the latest recommended DS4000 client software and RDAC levels
06.12.10.00
04.01.02.33
05.30.21.00
04.01.02.33
05.30.21.00
05.34.07.00
05.41.58.02
06.12.10.00
05.41.58.02
06.12.10.00
05.30.21.00
06.12.10.00
05.30.21.00
05.41.58.02
06.12.10.00
-
06.15.11.00


DS4000 (FAStT) Expansion Units

Expansion Units
Enclosure Firmware
Type
Notes
EXP100
9554
SATA
Concurrent download of code with I/O is not supported

SVC places no limitations on the existing DS4000 code and firmware upgrade processes

Please refer to DS4000 documentation on the DS4000 website for specific procedures and limitations
EXP500
9166
FC
EXP700
9327
FC
EXP710
9629
SBOD
EXP810
9865
FC


IBM DS6000

Model
Firmware
DS6800
Minimum DS6800 Licensed Machine Code level: 5.0.0

For further support, including interoperability details, see:
http://www-1.ibm.com/servers/storage/support/disk/ds6800/planning.html


IBM DS8000

Model
Firmware
DS8100
Minimum DS8100 Licensed Machine Code level: 5.0.0

For further support, including interoperability details, see:
http://www-1.ibm.com/servers/storage/support/disk/ds8100/planning.html
DS8300
Minimum DS8300 Licensed Machine Code level: 5.0.0

For further support, including interoperability details, see:
http://www-1.ibm.com/servers/storage/support/disk/ds8300/planning.html


IBM ESS

Model
Firmware
Notes
2105-E10
EC 2.2.0.693
EC 2.3.3.78
Dynamic expansion of controller LUNs is not supported
2105-E20
2105-F10
2105-F20
2105-800
EC 2.3.3.79
EC 2.4.2.31
2105-750
EC 2.4.2.31



HP

Model
Firmware
AKA
Notes
MA 8000
v8.7.F-7

Plus all no-charge upgrades from the vendor
HSG80
Your HP support representative will perform hardware maintenance and firmware upgrade procedures. These operations are non-disruptive to SVC

Dynamic expansion of controller LUNs is not supported

Refer to Configuration Guide which details specific requirements for attachment to SVC
EMA 12000
EMA 16000
EVA 3000
3.025
Your HP support representative will perform hardware maintenance and firmware upgrade procedures. These operations are non-disruptive to SVC

Dynamic expansion of controller LUNs is not supported

Refer to EVA product documentation for concurrent maintenance procedures
EVA 5000
XP48
01-18-71-00/00
HDS 9910
Your HP support representative will perform hardware maintenance and firmware upgrade procedures. These operations are currently not supported by SVC

Dynamic expansion of controller LUNs is not supported

Refer to Configuration Guide which details specific requirements for attachment to SVC
XP512
01-18-71-00/00
HDS 9960
XP128
21-11-02-00/00
HDS 9970V
XP1024
21-11-02-00/00
HDS 9980V


Hitachi Data Systems


HDS Thunder

Firmware

AKA

Notes

9200

055L

SANrise 1200

Your HDS support representative will perform hardware maintenance and firmware upgrade procedures. These operations are non-disruptive to SVC

Dynamic expansion of controller LUNs is not supported

Refer to Configuration Guide which details specific requirements for attachment to SVC

9520V

0656/A


1659AZ *


953xV / 9570V

065A/H


1659AZ *


9580V

1656/A


1659AZ *


9585V

1657/A


1659AZ *


HDS Lightning


AKA


9910

01-19-67-00/00

HP XP48
StorEdge 9910

Your HDS support representative will perform hardware maintenance and firmware upgrade procedures. These operations are currently not supported by SVC

Dynamic expansion of controller LUNs is not supported

Refer to Configuration Guide which details specific requirements for attachment to SVC

9960

01-19-67-00/00

HP XP512
StorEdge 9960

9970V

21-13-3-0/0

HP XP128
StorEdge 9970

9980V

21-13-3-0/0

HP XP1024
StorEdge 9980


EMC

EMC Clariion
Firmware
Notes
CX 200
02.16.200.5.012
Your EMC support representative will perform hardware maintenance and firmware upgrade procedures. These operations are non-disruptive to SVC

Dynamic expansion of controller LUNs is not supported

Refer to Configuration Guide which details specific requirements for attachment to SVC
CX 400
02.16.400.5.012
CX 600
02.16.600.5.012
CX 300
02.16.300.5.012
CX 500
02.16.500.5.012
CX 700
02.16.700.5.012
FC4700
08.51.60
Your EMC support representative will perform hardware maintenance and firmware upgrade procedures. Concurrent hardware maintenance operations are non-disruptive to SVC. This product requires I/O to be quiesced during firmware upgrade

Dynamic expansion of controller LUNs is not supported

Refer to Configuration Guide which details specific requirements for attachment to SVC
EMC Symmetrix
8000 Series (8130, 8230, 8430, 8530, 8730, 8830)
Enginuity 5568
Your EMC support representative will perform hardware maintenance and firmware upgrade procedures. Concurrent hardware maintenance operations are currently not supported by SVC.
Concurrent firmware upgrade is non-disruptive to SVC

Dynamic expansion of controller LUNs is not supported

Refer to Configuration Guide which details specific requirements for attachment to SVC
DMX & DMX-2 800/1000/2000/3000
Enginuity 5670


Sun StorEdge



Firmware

AKA

Notes

StorEdge 9910

01-19-67-00/00

HDS 9910

Your Sun support representative will perform hardware maintenance and firmware upgrade procedures. These operations are currently not supported by SVC

Dynamic expansion of controller LUNs is not supported

Refer to Configuration Guide which details specific requirements for attachment to SVC

StorEdge 9960

01-19-67-00/00

HDS 9960

StorEdge 9970

21-13-3-0/0

HDS 9970V

StorEdge 9980

21-13-3-0/0

HDS 9980V

StorageTek

StorageTek D-Series


Model
Firmware
NVSRAM
SANTricity
Notes
D173
5.30.23.00
N2772-530855-006
8.30.G2.05
D178
5.39.01.00
5.40.19.00
6.10.15.00
6.12.10.00
N4884-530855-005
N4884-540855-005
N4884-610855-006
N4884-612855-003
8.30.G2.00
8.40.G2.08
9.10.G2.03
9.15.G2.01
D220
5.34.08.00
N2882-534855-003
8.34.G2.05
D240
5.40.19.00
6.10.15.00
6.12.10.00
N2882-540855-007
N288X-610855-006
N288X-612855-003
8.40.G2.08
9.10.G2.03
9.15.G2.01
AKA FlexLine 240
D280
5.30.23.00
5.40.19.00
6.10.15.00
6.12.10.00
N5884-530855-005
N5884-540855-005
N588X-610855-006
N588X-612855-003
8.30.G2.05
8.40.G2.08
9.10.G2.03
9.15.G2.01
AKA FlexLine 280


StorageTek FlexLine 200 Series

Model
Firmware
NVSRAM
SANTricity
Notes
FLX210
6.12.10.00
N282X-612855-003
9.12.G2.01
FLX240
6.12.10.00
N288X-612855-003
9.12.G2.01
AKA D240
FLX280
6.12.10.00
N588X-612855-003
9.12.G2.01
AKA D280



SAN Switches

Brocade

IBM Model
Firmware
Class
AKA
Notes
5.0.1b
Fabric Switch
5.0.1b
Fabric Switch
5.0.1b
Fabric Switch
EMC DS-32B2
5.0.1b
Director
3.1.2a
Fabric Switch
3.1.2a
Fabric Switch
(fw) 3.0.2q when used with BladeCenter
2.6.2b
Fabric Switch

Cisco MDS

Model
Firmware
Class
AKA
Notes
2.1(2b)
Director
2062-D04
FCIP is supported. Maximum one way latency supported is 10ms

Support for up to 256 host attachment with level 2.1(1a) and above with SVC code level 2.1.0.4. Please refer to the Software Restrictions for further details
2062-D07
Fabric Switch
2062-D1A / D1H
2061-040
2061-020


iSCSI is supported on the Cisco MDS 9000 family. Please refer to the iSCSI Host Attachment section for more information

CNT

FC/9000 Model
Firmware
Class
AKA
Notes
3.0.5
Director, 1G
Asynchronous replication capabilities for SAN Volume Controller are available from CNT. For more information, please refer to this website: www.cnt.com/products/extension/ura
5.0.0
Director, 2G
V9.0.1.0

McDATA

IBM Name for IBM Badged Switch
McDATA Model
Firmware
Class
AKA
Notes
IBM# for IBM Badged Switch
IBM# for McDATA Badged Switch
Other
EOSc 08.00.01
Sphereon Fabric Switch
2031-016
Sphereon Fabric Switch
2031-032
Sphereon Fabric Switch
2031-216
IBM SAN32M-1
Sphereon Fabric Switch
2027-232
2031-232
IBM SAN24M-1
Sphereon Fabric Switch
2026-224
2031-224
Intrepid Director
2032-064
EMC ED-64M
IBM SAN140M-1
Intrepid Director
2027-140
2032-140
EMC ED-140M
IBM SAN256M
EOSn 06.01.00
Intrepid Director
2027-256



Other Hardware :

Technologies for extending the distance between two SVC clusters can be broadly divided into the following two categories. These extenders are only supported as inter cluster links and not intra cluster links, i.e. they should not be used between SVC nodes that are part of the same cluster.

Inter Cluster Fibre Channel Extenders

Fibre channel extenders simply extend a fibre channel link by transmitting fibre channel packets across long links without changing the contents of those packets. IBM has tested a number of such fibre channel extender technologies with SVC up to a maximum one way latency of 34ms and will support any fibre channel extender technology provided that it is planned, installed and tested meeting the requirements as detailed on the
Software Restrictions document.

Inter Cluster SAN Routers

SAN routers extend the scope of a SAN by providing "virtual nPorts" on two or more SANs. The router arranges that traffic at one virtual nPort is propagated to the other virtual nPort but the two fibre channel fabrics are independent of one another. Thus nPorts on each of the fabrics cannot directly log into each other.

Due to the more complex interactions involved, IBM explicitly tests products of this class for interoperability with SAN Volume Controller.

Distance limitations are defined below as latency measured in milliseconds (ms). Please visit the Software Restrictions document for more information.

Inter Cluster SAN Routers
Firmware
AKA
Notes
IBM# for IBM Badged Switch
SAN04M-R SAN Router
McDATA Eclipse 1620 SAN Router
4.5
2027-R04
Maximum round trip latency is 20ms (10ms one way)
SAN16M-R SAN Router
McDATA Eclipse 2640 SAN Router
4.6.2
2027-R16
Cisco MDS 9000 Series Inter VSAN Routing
2.1(2b)
Successful test results have been obtained with packet latencies of up to 10ms



Microsoft Cluster Certified Configurations

Host Bus Adapter
Configurations
Notes
Emulex LP9002
HP_Server_Microsoft_Cluster_Configurations_LP9002.xls
DL380G2
DL380G3
DL380G4
ML570
DL740
Please visit the V2.1.0 Recommended Software Levels for host operating system information
Emulex LP9802
HP_Server_Microsoft_Cluster_Configurations_LP9802.xls
DL380G2
DL380G3
DL380G4
ML570
DL740
Emulex LP10000
HP_Server_Microsoft_Cluster_Configurations_LP10000.xls
DL380G4


IBM TotalStorage NAS Gateway 500

TotalStorage NAS Gateway 500
NAS System Software
Type
Model
NAS v1.1.1