IBM Support

SMP/E Installation of DB2 Object Comparison Tool V2.1 Fails in the APPLY Step - Missing Prerequisite.

Question & Answer


Question

SMP/E APPLY job fails for DB2® Object Comparison Tool V2.1 (H25G210) if certain conditions are not met.

Answer

The SMP/E APPLY job fails for DB2 Object Comparison Tool V2.1 (H25G210) if the following conditions are not met:



    1. Installation must be in the same global zone and the same target zone, with DB2 Administration Tool V4 being used. In situations where different CSI/ZONES or same CSI but different ZONES are used for Administration Tool R410 and for Administration Tool R420, each installation of Administration Tool will need its own copy of Object Compare.

    2. Installation of H25G210 base and Rollup PTF UQ68367 must be at the same time and both applied in a single SMP/E job.
Object Compare requires Administration Tool, but Administration Tool does not require Object Compare.

If the above steps are not followed, you might receive the following messages:

    "Apply processing failed for sysmod H25G210. Required sysmods failed or were missing. Prerequisite sysmod H0IH410 was missing."

    "Apply processing stopped because function sysmod H25G210 failed."


    GIM30209E "APPLY PROCESSING FAILED FOR SYSMOD H25G210. REQUIRED SYSMODS FAILED OR WERE MISSING."

    GIM35916I "CONDITIONAL REQUISITE SYSMOD UQ68367 WAS MISSING. SYSMOD H0IH420 CONTAINED THE ++IF STATEMENT."

    GIM37001S "APPLY PROCESSING STOPPED BECAUSE FUNCTION SYSMOD H25G210 FAILED."

[{"Product":{"code":"SSCVQTD","label":"IBM Db2 Administration Tool for z\/OS"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Component":"DB2 Object Comparison Tool","Platform":[{"code":"PF035","label":"z\/OS"}],"Version":"2.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
12 February 2021

UID

swg21167858