Question & Answer
Question
When using DB2® Log Analysis Tool, a general report is created without error. Then, the JCL for a detail report is generated and submitted but the job fails with RC00016, and the following error message is generated: ALAA156I: START EDICT/SORT WER400A DMTLAT ,STEP4 , -EDICT IS AN UNINITIALIZED SEQUENTI ALAA352E-General SORT failure...see SYSOUT output for step IEF404I DMTLAT - ENDED - TIME=13.46.57 AUTOCODE DMTLAT STEP4 RCODE00016 J24666
Answer
When this problem occurs, it is likely that SyncSort is rejecting an unitialized input dataset.
To resolve RC00016, try one of the following:
- Bypass SYNCSORT (if possible) and use native Sort.
- Or, the SyncSort parm "UNINTDS" can be set (='YES') to allow SyncSort to handle this situation as well. A setting of 'NO' is the SYNCSORT default, but that stops processes (such as this) that don't need to be stopped.
Was this topic helpful?
Document Information
Modified date:
11 February 2021
UID