Troubleshooting
Problem
In ACF2 environments, DB2 Cloning Tool for z/OS programs might end with the error message 'IKJ56500I COMMAND XXXXXXX NOT FOUND'. If you use CA ACF2™ as a security product, you might encounter 'IKJ56500I COMMAND XXXXXXX NOT FOUND' errors when you run DB2 Cloning Tool for z/OS. DB2 Cloning Tool programs that run as TSO commands must be added to the ACF2 Command Limiting Table.
Symptom
The error message 'IKJ56500I COMMAND XXXXXXX NOT FOUND'.
Cause
This event is caused by differences in behavior between RACF and CA ACF2 products.
Resolving The Problem
To resolve the problem, add the following DB2 Cloning Tool programs to ACF2's Command Limiting Table:
CKZARGSZ
CKZ2MAIN
CKZ00500
CKZ00600
Was this topic helpful?
Document Information
Modified date:
11 February 2021
UID
swg21661441