APAR status
Closed as program error.
Error description
On a 4694 model 245 running Ethernet, the OFFLINE light remains on after coming out of SLEEP mode. When a key is pressed, the terminal wakes up and will function correctly, but the OFFLINE light remains on, and stays on until the terminal is reloaded. When running the Device Channel trace, it wil not fail every time. Without the trace active, it fails every time. Dump is L23, and Device Chanel trace is M01.
Local fix
Problem summary
The keyboard was not responding to a reset from the APM driver. As a result, the keyboard driver wasn't updating the lights reliably.
Problem conclusion
Hardware fixed the code which is loaded into the keyboard to respond to a reset. This causes the code to be reloaded, causing a ROL which causes the driver to update the lights to the current state.
Temporary fix
Comments
APAR Information
APAR number
IR47798
Reported component name
IBM 4690 OS VER
Reported component ID
5639F5300
Reported release
401
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2002-02-21
Closed date
2002-10-07
Last modified date
2003-01-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
ADXMC50F
Fix information
Fixed component name
IBM 4690 OS VER
Fixed component ID
5639F5300
Applicable component levels
R401 PSY UR53871
UP02/11/07 I 1000
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SOULYT","label":"Point of Sale Software->4690 Operating System"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"401","Edition":"","Line of Business":{"code":"","label":""}}]