Fixes are available
APAR status
Closed as program error.
Error description
Using complex XPath expressions in diagrams which use "or" and "and" statements will result in warnings like this in the SystemOut.log file on the server or cluster where the monitor model is running: com.ibm.wbimonitor.xml.expression.core.XPathExpressionMarker: WARNING: X25 The and subexpression always evaluates to false. (259 - 362) X25 The and subexpression always evaluates to false. (2 - 97) X27 The or subexpression always evaluates to false. (0 - 447) X27 The or subexpression always evaluates to false. (0 - 632)
Local fix
Rewrite the XPath expression to use if/then/else constructs instead.
Problem summary
This problem exists in IBM Business Monitor V7.5.1.
Problem conclusion
This problem is resolved in IBM Business Monitor V7.5.1.0 Interim Fix JR41788, available at: http://www.ibm.com/support/docview.wss?uid=swg24032194
Temporary fix
Comments
APAR Information
APAR number
JR41788
Reported component name
WEB BUS MONITOR
Reported component ID
5724M2400
Reported release
750
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-01-31
Closed date
2012-03-30
Last modified date
2012-04-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEB BUS MONITOR
Fixed component ID
5724M2400
Applicable component levels
R751 PSY
UP