Fixes are available
8.0.0.3: WebSphere Application Server V8.0 Fix Pack 3
8.0.0.4: WebSphere Application Server V8.0 Fix Pack 4
8.0.0.5: WebSphere Application Server V8.0 Fix Pack 5
8.0.0.6: WebSphere Application Server V8.0 Fix Pack 6
8.0.0.7: WebSphere Application Server V8.0 Fix Pack 7
8.0.0.8: WebSphere Application Server V8.0 Fix Pack 8
8.0.0.9: WebSphere Application Server V8.0 Fix Pack 9
8.0.0.10: WebSphere Application Server V8.0 Fix Pack 10
8.0.0.11: WebSphere Application Server V8.0 Fix Pack 11
8.0.0.12: WebSphere Application Server V8.0 Fix Pack 12
8.0.0.13: WebSphere Application Server V8.0 Fix Pack 13
8.0.0.14: WebSphere Application Server V8.0 Fix Pack 14
8.0.0.15: WebSphere Application Server V8.0 Fix Pack 15
APAR status
Closed as program error.
Error description
after applying PM48786, the SIP container puts display names in double quotes.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All Session Initiation Protocol (SIP) * * container users of IBM WebSphere * * Application Server V8.0 * **************************************************************** * PROBLEM DESCRIPTION: There is no option to write Address * * object with brackets when there is no * * display name. * **************************************************************** * RECOMMENDATION: * **************************************************************** The SIP container is writing Address objects without brackets if there is no display name. when display name is set to empty string the SIP container is adding commas around it.
Problem conclusion
A new custom property was added to allow the user to decide that every Address object will be written with brackets around the URI section even if the display name is empty. To enable the new custom property: 1. log in to the WebSphere administrative console 2. go to Application servers > server1 > SIP container > Custom properties 3. click on new 4. add custom property name: force.name.addr value: true 5. click on ok 6. restart the SIP container The fix for this APAR is currently targeted for inclusion in fix pack 8.0.0.4. Please refer to the Recommended Updates page for delivery information: http://www.ibm.com/support/docview.wss?rs=180&uid=swg27004980
Temporary fix
Comments
APAR Information
APAR number
PM52841
Reported component name
CEA FEATUREPACK
Reported component ID
5724J0855
Reported release
800
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-11-23
Closed date
2012-03-12
Last modified date
2012-03-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
PM58750 PM69486
Fix information
Fixed component name
WEBS APP SERV N
Fixed component ID
5724H8800
Applicable component levels
R800 PSY
UP
Document Information
Modified date:
28 October 2021