IBM Support

PM33245: A VALUE STARTING WITH A NUMERIC CHAR CAN NOT BE SET FOR THE SYSTEM NAME DURING WCT/ZPMT PROFILE CUSTOMIZATION.

Fixes are available

7.0.0.19: WebSphere Application Server V7.0 Fix Pack 19
7.0.0.21: WebSphere Application Server V7.0 Fix Pack 21
7.0.0.23: WebSphere Application Server V7.0 Fix Pack 23
7.0.0.25: WebSphere Application Server V7.0 Fix Pack 25
7.0.0.27: WebSphere Application Server V7.0 Fix Pack 27
7.0.0.29: WebSphere Application Server V7.0 Fix Pack 29
7.0.0.31: WebSphere Application Server V7.0 Fix Pack 31
7.0.0.27: Java SDK 1.6 SR13 FP2 Cumulative Fix for WebSphere Application Server
7.0.0.33: WebSphere Application Server V7.0 Fix Pack 33
7.0.0.35: WebSphere Application Server V7.0 Fix Pack 35
7.0.0.37: WebSphere Application Server V7.0 Fix Pack 37
7.0.0.39: WebSphere Application Server V7.0 Fix Pack 39
7.0.0.41: WebSphere Application Server V7.0 Fix Pack 41
7.0.0.43: WebSphere Application Server V7.0 Fix Pack 43
7.0.0.45: WebSphere Application Server V7.0 Fix Pack 45
7.0.0.19: Java SDK 1.6 SR9 FP2 Cumulative Fix for WebSphere Application Server
7.0.0.21: Java SDK 1.6 SR9 FP2 Cumulative Fix for WebSphere
7.0.0.23: Java SDK 1.6 SR10 FP1 Cumulative Fix for WebSphere
7.0.0.25: Java SDK 1.6 SR11 Cumulative Fix for WebSphere Application Server
7.0.0.27: Java SDK 1.6 SR12 Cumulative Fix for WebSphere Application Server
7.0.0.29: Java SDK 1.6 SR13 FP2 Cumulative Fix for WebSphere Application Server
7.0.0.45: Java SDK 1.6 SR16 FP60 Cumulative Fix for WebSphere Application Server
IBM WebSphere Customization Tools V7.0 for Windows
IBM WebSphere Customization Tools V7.0 for Linux
7.0.0.31: Java SDK 1.6 SR15 Cumulative Fix for WebSphere Application Server
7.0.0.35: Java SDK 1.6 SR16 FP1 Cumulative Fix for WebSphere Application Server
7.0.0.37: Java SDK 1.6 SR16 FP3 Cumulative Fix for WebSphere Application Server
7.0.0.39: Java SDK 1.6 SR16 FP7 Cumulative Fix for WebSphere Application Server
7.0.0.41: Java SDK 1.6 SR16 FP20 Cumulative Fix for WebSphere Application Server
7.0.0.43: Java SDK 1.6 SR16 FP41 Cumulative Fix for WebSphere Application Server

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • WCT/zPMT incorrectly restricts the customers from entering the
    value of the system name. When the value starting with a numeric
    char is entered, zPMT blocks it with an error message. In fact,
    the numeric chars are valid for system name as listed in the MVS
    Initialization and Tuning Reference
    May see the following error:
    osgi> The following validation errors were present with the
    command line arguments:
    zSystemName: zSystemName contains one or more characters that
    are not valid.
    

Local fix

  • In the "DATA" PDS member of the zPMT customization jobs, there
    will be a member with the name of BBOWRESx (where x is P for app
    server, D for management or M for managed node). The value of
    z.system.name can be changed to the actual system name. (For
    management, the value of z.deamon.instance.name also needs to be
    changed.)
    One approach would be to assign a system name of, say ZZZZZZZZ,
    and then replace all occurrences of ZZZZZZZZ in the respective
    file.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:  All WebSphere Application Server for z/OS   *
    *                  Version 6.1 and Version 7.0 users that use  *
    *                  the Profile Management Tool for z/OS that   *
    *                  is contained within the WebSphere           *
    *                  Customization Tools Version 7.0 to          *
    *                  customize WebSphere Application Server for  *
    *                  z/OS.                                       *
    ****************************************************************
    * PROBLEM DESCRIPTION: The Profile Management Tool for z/OS    *
    *                      does not allow a leading numeric        *
    *                      character to be specified for the       *
    *                      z/OS system name.                       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    The Profile Management Tool for z/OS that is contained within
    WebSphere Customization Tools Version 7.0 will not allow
    a numeric to be specified as the first character of a
    z/OS system name.
    

Problem conclusion

  • The Profile Management Tool for z/OS that is contained within
    WebSphere Customization Tools service level 7.0.0.19 will
    allow users to specify a leading numeric character for the z/OS
    system name.
    
    WebSphere Customization Tools service level 7.0.0.19, when
    available, can be downloaded from the following site:
    
    http://www-01.ibm.com/support/docview.wss?rs=180&uid=swg24020368
    

Temporary fix

  • A patch is available for WebSphere Customization Tools
    7.0.0.17 that corrects the problem. Please contact L2 to get
    the patch.
    

Comments

APAR Information

  • APAR number

    PM33245

  • Reported component name

    WEBSPHERE CUST

  • Reported component ID

    5655N0213

  • Reported release

    700

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-02-21

  • Closed date

    2011-06-07

  • Last modified date

    2012-08-08

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WEBSPHERE CUST

  • Fixed component ID

    5655N0213

Applicable component levels

  • R700 PSY

       UP