Fixes are available
6.1.0.37: Java SDK 1.5 SR12 FP3 Cumulative Fix for WebSphere
7.0.0.17: Java SDK 1.6 SR9 FP1 Cumulative Fix for WebSphere Application Server
6.1.0.47: WebSphere Application Server V6.1 Fix Pack 47
7.0.0.27: Java SDK 1.6 SR13 FP2 Cumulative Fix for WebSphere Application Server
6.1.0.39: Java SDK 1.5 SR12 FP4 Cumulative Fix for WebSphere Application Server
6.1.0.41: Java SDK 1.5 SR12 FP5 Cumulative Fix for WebSphere Application Server
6.1.0.43: Java SDK 1.5 SR13 Cumulative Fix for WebSphere Application Server
6.1.0.45: Java SDK 1.5 SR14 Cumulative Fix for WebSphere Application Server
6.1.0.47: Java SDK 1.5 SR16 Cumulative Fix for WebSphere Application Server
7.0.0.19: Java SDK 1.6 SR9 FP2 Cumulative Fix for WebSphere Application Server
7.0.0.21: Java SDK 1.6 SR9 FP2 Cumulative Fix for WebSphere
7.0.0.23: Java SDK 1.6 SR10 FP1 Cumulative Fix for WebSphere
7.0.0.25: Java SDK 1.6 SR11 Cumulative Fix for WebSphere Application Server
7.0.0.27: Java SDK 1.6 SR12 Cumulative Fix for WebSphere Application Server
7.0.0.29: Java SDK 1.6 SR13 FP2 Cumulative Fix for WebSphere Application Server
7.0.0.45: Java SDK 1.6 SR16 FP60 Cumulative Fix for WebSphere Application Server
7.0.0.31: Java SDK 1.6 SR15 Cumulative Fix for WebSphere Application Server
7.0.0.35: Java SDK 1.6 SR16 FP1 Cumulative Fix for WebSphere Application Server
7.0.0.37: Java SDK 1.6 SR16 FP3 Cumulative Fix for WebSphere Application Server
7.0.0.39: Java SDK 1.6 SR16 FP7 Cumulative Fix for WebSphere Application Server
7.0.0.41: Java SDK 1.6 SR16 FP20 Cumulative Fix for WebSphere Application Server
7.0.0.43: Java SDK 1.6 SR16 FP41 Cumulative Fix for WebSphere Application Server
APAR status
Closed as program error.
Error description
If node sync reaches the maximum number of retry, no warning message is issued when the iteration limit has been reached. ADMS0023I: A synchronization operation reached the iteration limit. Retry happens when there is continuous dmgr config updates (e.g continuous application installation). In this case, node synchronization may take more time. There is no impact in terms of functionality, but showing warning message is for better debugging purpose. For example, in a customer situation where there is a delay in node synchronization operation, this warning is helpful to conclude whether the delay is because of node sync retry (or) some other performance issues.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM WebSphere Application * * Server version 6.1 and 7.0. * **************************************************************** * PROBLEM DESCRIPTION: No warning message in system out if * * node synchronization reaches its max * * retry limit. * **************************************************************** * RECOMMENDATION: * **************************************************************** ADMS0023I is not issued when node synchronization reaches its max retry limit. Whenever customer encounters delay in node synchronization, this warning message is useful to debug whether this delay is due to node synchronization retry (or) any other performance issues. Please note, all these retries happen in a single node synchronization activity. Retry is not transparent to the customer.
Problem conclusion
Source code has been modified to issue the retry warning message. The fix for this APAR is currently targeted for inclusion in fix packs 6.1.0.37 and 7.0.0.17. Please refer to the Recommended Updates page for delivery information: http://www.ibm.com/support/docview.wss?rs=180&uid=swg27004980
Temporary fix
Comments
APAR Information
APAR number
PM27244
Reported component name
WEBS APP SERV N
Reported component ID
5724H8800
Reported release
61S
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-11-22
Closed date
2010-12-01
Last modified date
2013-04-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEBS APP SERV N
Fixed component ID
5724H8800
Applicable component levels
R61A PSY
UP
R61H PSY
UP
R61I PSY
UP
R61P PSY
UP
R61S PSY
UP
R61W PSY
UP
R61Z PSY
UP
R700 PSY
UP
Document Information
Modified date:
27 October 2021