PI19322: RESTRICT LONG RUNNING LOCKS WARNING MESSAGES LOGGED EVEN THOUGH THE FEATURE IS NOT ENABLED

Fixes are available

8.5.5.4: WebSphere Application Server V8.5.5 Fix Pack 4
8.0.0.10: WebSphere Application Server V8.0 Fix Pack 10
7.0.0.37: WebSphere Application Server V7.0 Fix Pack 37
8.5.5.5: WebSphere Application Server V8.5.5 Fix Pack 5
8.5.5.6: WebSphere Application Server V8.5.5 Fix Pack 6
8.0.0.11: WebSphere Application Server V8.0 Fix Pack 11
8.5.5.7: WebSphere Application Server V8.5.5 Fix Pack 7
7.0.0.39: WebSphere Application Server V7.0 Fix Pack 39
8.5.5.8: WebSphere Application Server V8.5.5 Fix Pack 8
8.0.0.12: WebSphere Application Server V8.0 Fix Pack 12
8.5.5.9: WebSphere Application Server V8.5.5 Fix Pack 9
7.0.0.41: WebSphere Application Server V7.0 Fix Pack 41
8.5.5.10: WebSphere Application Server V8.5.5 Fix Pack 10
8.5.5.11: WebSphere Application Server V8.5.5 Fix Pack 11
8.0.0.13: WebSphere Application Server V8.0 Fix Pack 13
7.0.0.43: WebSphere Application Server V7.0 Fix Pack 43
8.5.5.12: WebSphere Application Server V8.5.5 Fix Pack 12
8.0.0.14: WebSphere Application Server V8.0 Fix Pack 14
8.5.5.13: WebSphere Application Server V8.5.5 Fix Pack 13
7.0.0.45: WebSphere Application Server V7.0 Fix Pack 45
8.0.0.15: WebSphere Application Server V8.0 Fix Pack 15
7.0.0.45: Java SDK 1.6 SR16 FP60 Cumulative Fix for WebSphere Application Server
7.0.0.37: Java SDK 1.6 SR16 FP3 Cumulative Fix for WebSphere Application Server
7.0.0.39: Java SDK 1.6 SR16 FP7 Cumulative Fix for WebSphere Application Server
7.0.0.41: Java SDK 1.6 SR16 FP20 Cumulative Fix for WebSphere Application Server
7.0.0.43: Java SDK 1.6 SR16 FP41 Cumulative Fix for WebSphere Application Server
8.5.5.14: WebSphere Application Server V8.5.5 Fix Pack 14
8.5.5.15: WebSphere Application Server V8.5.5 Fix Pack 15
8.5.5.14: WebSphere Application Server V8.5.5 Fix Pack 14
8.5.5.17: WebSphere Application Server V8.5.5 Fix Pack 17
8.5.5.20: WebSphere Application Server V8.5.5.20
8.5.5.18: WebSphere Application Server V8.5.5 Fix Pack 18
8.5.5.19: WebSphere Application Server V8.5.5 Fix Pack 19
8.5.5.16: WebSphere Application Server V8.5.5 Fix Pack 16
8.5.5.21: WebSphere Application Server V8.5.5.21

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • In Websphere Application Server v7.0.0.x, the following
    warning messages are logged in the SystemOut.log though
    the "RESTRICT LONG RUNNING LOCKS" feature is not enabled on
    the Service Integration Bus messaging engine:
    SibMessage    W  [XXX_bus:XYZ_Cluster.000-XXX_bus] Restrict
    DB locking feature cannot be enabled, since Messaging
    Engine is trying to connect to the datastore that is
    incompatible or not supported with this version of WAS .
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:  Users of the default messaging provider for *
    *                  IBM WebSphere Application Server            *
    ****************************************************************
    * PROBLEM DESCRIPTION: When "Restrict long running locks"      *
    *                      feature is not enabled for a messaging  *
    *                      engine then the CWSIS1602W message      *
    *                      should                                  *
    *                      not be logged in the SystemOut.log      *
    *                      files.                                  *
    ****************************************************************
    * RECOMMENDATION:  None                                        *
    ****************************************************************
    When "Restrict long running locks" feature is not enabled for a
    messaging engine then the below message should not be logged in
    the SystemOut.log files.
    [5/22/14 17:01:36:803 CEST] 00000011 SibMessage    W
    [itim_bus:ITIM_Messaging_Cluster.000-itim_bus] CWSIS1602W:
    Restrict DB locking feature cannot be enabled, since Messaging
    Engine is trying to connect to the datastore that is
    incompatible or not supported with this version of WAS
    However the message is observed in the SystemOut.log files
    even when the feature is not enabled.
    

Problem conclusion

  • The message is conveying the information that the sibDBUpgrade
    script is not run on the SIB tables. The "Restrict long
    running locks" feature requires some schema changes to the
    SIB tables. This script performs these changes. While
    starting, the messaging engine can detect if the feature is
    enabled and the required changes are not made to SIB tables
    through the script. If it is the case, the feature is disabled
    and default behaviour to use the long running locks is applied.
    
    The fix for this APAR is currently targeted for inclusion in
    fix packs 7.0.0.37, 8.0.0.10, 8.5.5.4.  Please refer to the
    Recommended Updates page for delivery information:
    http://www.ibm.com/support/docview.wss?rs=180&uid=swg27004980
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI19322

  • Reported component name

    WAS SIB & SIBWS

  • Reported component ID

    620800101

  • Reported release

    300

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-06-04

  • Closed date

    2014-09-09

  • Last modified date

    2015-01-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WAS SIB & SIBWS

  • Fixed component ID

    620800101

Applicable component levels

  • R800 PSY

       UP

  • R850 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSEQTP","label":"WebSphere Application Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
28 April 2022