Readmes are available
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 1 README 4.0.0.14-TIV-SSM-IF0001
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 2 README 4.0.0.14-TIV-SSM-IF0002
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 1 README 4.0.1.1-TIV-SSM-IF0001
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 2 README 4.0.1.1-TIV-SSM-IF0002
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 3 README 4.0.0.14-TIV-SSM-IF0003
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 3 README 4.0.1.1-TIV-SSM-IF0003
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 4 README 4.0.0.14-TIV-SSM-IF0004
IBM Netcool System Service Monitor SSM 4.0 Fix Pack 2 README 4.0.1-TIV-SSM-FP0002
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 1 README 4.0.1.2-TIV-SSM-IF0001
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 5 README 4.0.0.14-TIV-SSM-IF0005
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 2 README 4.0.1.2-TIV-SSM-IF0002
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 6 README 4.0.0.14-TIV-SSM-IF0006
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 3 README 4.0.1.2-TIV-SSM-IF0003
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 7 README 4.0.0.14-TIV-SSM-IF0007
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 4 README 4.0.1.2-TIV-SSM-IF0004
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 8 README 4.0.0.14-TIV-SSM-IF0008
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 1 README 4.0.1.3-TIV-SSM-IF0001
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 1 README 4.0.0.15-TIV-SSM-IF0001
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 2 README 4.0.1.3-TIV-SSM-IF0002
APAR status
Closed as program error.
Error description
psControlRows in the process MIB can generate spurious alarms occasionally. This is because the last sample can return with a value of 0 for all plib metrics. This in turn generates incorrect samples and alerts.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * SSM Process subagent on Unix * **************************************************************** * PROBLEM DESCRIPTION: * * The Process subagent can report incorrect values in the * * notifications generated by the psControlTable ( psException * * traps and informs ). This will happen with delta based * * metrics, eg CPU Percentage, when the process being monitored * * terminates while the sample is being taken. A common * * example of this is when monitoring the CPU Percentage, this * * will cause the value to become 100% and cause incorrect * * alerts to appear in monitoring systems. This is more likely * * to happen on systems when large numbers of processes are * * being monitored and they are routinely being terminated and * * created. * **************************************************************** * RECOMMENDATION: * * Upgrade to SSM 4.0.1.1 IF0001 * ****************************************************************
Problem conclusion
The fix for this APAR is contained in the following maintenance packages: | interim fix | 4.0.0.14-TIV-SSM-IF0001 | interim fix | 4.0.1.1-TIV-SSM-IF0001
Temporary fix
Comments
APAR Information
APAR number
IV53821
Reported component name
NETCOOL SYS SVC
Reported component ID
5724P4300
Reported release
400
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2014-01-09
Closed date
2014-02-26
Last modified date
2014-03-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
NETCOOL SYS SVC
Fixed component ID
5724P4300
Applicable component levels
Document Information
Modified date:
05 March 2014