Readmes are available
IBM Netcool System Service Monitor SSM 4.0 Fix Pack 13 README 4.0.0-TIV-SSM-FP0013
IBM Netcool System Service Monitor SSM 4.0 Fix Pack 14 README 4.0.0-TIV-SSM-FP0014
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 1 README 4.0.0.14-TIV-SSM-IF0001
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 2 README 4.0.0.14-TIV-SSM-IF0002
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 3 README 4.0.0.14-TIV-SSM-IF0003
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 4 README 4.0.0.14-TIV-SSM-IF0004
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 5 README 4.0.0.14-TIV-SSM-IF0005
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 6 README 4.0.0.14-TIV-SSM-IF0006
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 7 README 4.0.0.14-TIV-SSM-IF0007
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 8 README 4.0.0.14-TIV-SSM-IF0008
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 1 README 4.0.0.15-TIV-SSM-IF0001
APAR status
Closed as program error.
Error description
The OIDs in the FileMon Notifications for fmDataTable based varbinds are incorrect, as one of the indexes is the path and file name but does not have a preceding length specifier and does not match the OID for the same object in the fmDataTable.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of the FileMon sub-agent. * **************************************************************** * PROBLEM DESCRIPTION: * * When the FileMon sub-agent was creating Varbinds for FileMon * * bases SNMP notifications the Object IDs for fmDataTable * * objects were incorrect and differed from the ObjectIDs of * * the entries in the table. This was because the length part * * of a OctetString index was missing. * **************************************************************** * RECOMMENDATION: * * Upgrade to SSM Fix Pack 13 * ****************************************************************
Problem conclusion
Length part of the Octect String was added to the Object ID. The fix for this APAR is contained in the following maintenance packages: | fix pack | 4.0.0-TIV-SSM-FP0013
Temporary fix
Comments
APAR Information
APAR number
IV18001
Reported component name
NETCOOL SYS SVC
Reported component ID
5724P4300
Reported release
400
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2012-03-21
Closed date
2012-03-21
Last modified date
2012-03-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
NETCOOL SYS SVC
Fixed component ID
5724P4300
Applicable component levels
R400 PSY
UP
Document Information
Modified date:
21 March 2012