IBM Support

SI62596 - OSP-MSGMCH2603-PAR-940XCOM CPYTOSTMF FAILS WITH MSGMCH2603 F

PTF ( Program Temporary Fixes ) Cover letter


Order this fix

Abstract

OSP-MSGMCH2603-PAR-940XCOM CPYTOSTMF FAILS WITH MSGMCH2603 F


Pre/Co-Requisite PTF / Fix List

REQ  LICENSED           PTF/FIX  LEVEL

TYPE PROGRAM  RELEASE   NUMBER   MIN/MAX  OPTION
---- -------- --------- -------  -------  ------
NONE



NOTICE:
-------
Application of this PTF may disable or render ineffective programs that
use system memory addresses not generated by the IBM translator,
including programs that circumvent control technology designed to limit
interactive capacity to purchased levels.  This PTF may be a prerequisite
for future PTFs.  By applying this PTF you authorize and agree to the
foregoing.

This PTF is subject to the terms of the license agreement which
accompanied, or was contained in, the Program for which you are obtaining
the PTF.  You are not authorized to install or use the PTF except as part
of a Program for which you have a valid Proof of Entitlement.

SUBJECT TO ANY WARRANTIES WHICH CAN NOT BE EXCLUDED OR EXCEPT AS EXPLICITLY
AGREED TO IN THE APPLICABLE LICENSE AGREEMENT OR AN APPLICABLE SUPPORT
AGREEMENT, IBM MAKES NO WARRANTIES OR CONDITIONS EITHER EXPRESS OR IMPLIED,
INCLUDING BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OR CONDITIONS OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON INFRINGEMENT,
REGARDING THE PTF.

The applicable license agreement may have been provided to you in printed
form and/or may be viewed using the Work with Software Agreements (WRKSFWAGR)
CL command.





APAR Error Description / Circumvention

-----------------------------------------------
CPYTOSTMF FROMMBR('/qsys.lib/BAUERM.lib/SCSAVF.file')
TOSTMF('/QfileSvr.400/faba4306/qsys.lib/BAUERM.lib/SCSAVF.file')
STMFOPT(*replace)

fails from R720 to a remote R720 and
works fine and stable from R720 to a remote R710 IBM i

CORRECTION FOR APAR SE65826 :
-----------------------------
This issue does not only occur through QFileSvr.400, but also
occurs if ANY non-empty save file is as the output TOSTMF. This
is bacause that the target save file information is incorrectly
removed in open operation and finally cause write operation
failed.

CIRCUMVENTION FOR APAR SE65826 :
--------------------------------
None.


Activation Instructions


None.




Special Instructions


********************************************************************
THE FOLLOWING ARE SUPERSEDED SPECIAL INSTRUCTIONS. IF THE SUPERSEDED
PTF HAS ALREADY BEEN APPLIED AND ITS SPECIAL INSTRUCTION FOLLOWED,
IT IS NOT NECESSARY TO FOLLOW THAT SPECIAL INSTRUCTION AGAIN.
********************************************************************

SPECIAL INSTRUCTIONS FOR SUPERSEDED PTF SI51512 :
=================================================

After installing this PTF, the machine need been IPLed.


Default Instructions

THIS IS A DELAYED PTF TO BE APPLIED AT IPL TIME.



Supersedes

PTF/FIX NO(S).  APAR TITLE LINE
--------------  ------------------------------------------------------------
   SI51512      OSP-PAR-940XPWR Update open() API for AFP object support SEE

Summary Information

System.............................. i
Models..............................
Release............................. V7R2M0
Licensed Program............... 5770SS1
APAR Fixed.......................... View details for APAR SE65826
Superseded by:......................
Recompile........................... N
Library............................. QSYS
MRI Feature ........................ NONE
Cum Level........................... C7068720


System i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information.

Document information

More support for: i family

Software version: V7R2M0

Operating system(s): OS/400

Reference #: SI62596

Modified date: 20 October 2016