IBM Support

SI55532 - OSP-OTHER Support for new data in PEX ACTGRPDLT trace event

PTF ( Program Temporary Fixes ) Cover letter


Order this fix

Abstract

OSP-OTHER Support for new data in PEX ACTGRPDLT trace event


Pre/Co-Requisite PTF / Fix List

REQ  LICENSED      PTF/FIX  LEVEL

TYPE PROGRAM  REL  NUMBER   MIN/MAX  OPTION
---- -------- ---  -------  -------  ------
PRE  5770999  710  MF55141   00/00    0000
PRE  5770999  710  MF51463   00/00    0000
DIST 5770999  710  MF59643   00/00    0000



NOTICE:
-------
Application of this PTF may disable or render ineffective programs that
use system memory addresses not generated by the IBM translator,
including programs that circumvent control technology designed to limit
interactive capacity to purchased levels.  This PTF may be a prerequisite
for future PTFs.  By applying this PTF you authorize and agree to the
foregoing.

This PTF is subject to the terms of the license agreement which
accompanied, or was contained in, the Program for which you are obtaining
the PTF.  You are not authorized to install or use the PTF except as part
of a Program for which you have a valid Proof of Entitlement.

SUBJECT TO ANY WARRANTIES WHICH CAN NOT BE EXCLUDED OR EXCEPT AS EXPLICITLY
AGREED TO IN THE APPLICABLE LICENSE AGREEMENT OR AN APPLICABLE SUPPORT
AGREEMENT, IBM MAKES NO WARRANTIES OR CONDITIONS EITHER EXPRESS OR IMPLIED,
INCLUDING BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OR CONDITIONS OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON INFRINGEMENT,
REGARDING THE PTF.

The applicable license agreement may have been provided to you in printed
form and/or may be viewed using the Work with Software Agreements (WRKSFWAGR)
CL command.


APAR Error Description / Circumvention

-------------------------------------------------
PEX needs to support additional data in the Activation Group
Destroy event.  This event is specified by BASEVT(*ACTGRPDLT) in
the ADDPEXDFN command.

CORRECTION FOR APAR 'SE60792' :
-------------------------------
Support for new data in the Activation Group Destroy event has
been added in this PTF.

The new data is placed in the following fields in the PEX file
QAYPEBASE:

Field QBSH05 - Size of static storage in bytes for the initial
round of activation upon creation of the activation group

Field QBSH06 - Size of static storage in bytes for the life of
the activation group

Field QBSH07 - Size of thread local static storage in bytes for
the life of the activation group

CIRCUMVENTION FOR APAR 'SE60792' :
----------------------------------
None.


Activation Instructions


None.




Special Instructions

After applying or removing this PTF, sign off and then back on to
activate the changed service programs.

To enable the collection of the new data supported by this PTF, PTF
MF59643 must also be applied.

********************************************************************
THE FOLLOWING ARE SUPERSEDED SPECIAL INSTRUCTIONS. IF THE SUPERSEDED
PTF HAS ALREADY BEEN APPLIED AND ITS SPECIAL INSTRUCTION FOLLOWED,
IT IS NOT NECESSARY TO FOLLOW THAT SPECIAL INSTRUCTION AGAIN.
********************************************************************

SPECIAL INSTRUCTIONS FOR SUPERSEDED PTF SI37984 :
=================================================

After applying or removing this PTF, sign off and then back on to
activate the changed service programs.

SPECIAL INSTRUCTIONS FOR SUPERSEDED PTF SI49885 :
=================================================

After applying or removing this PTF, sign off and then back on to
activate the changed service program.


Default Instructions

THIS PTF CAN BE APPLIED IMMEDIATE OR DELAYED.



Supersedes

PTF/FIX NO(S).  APAR TITLE LINE
--------------  ------------------------------------------------------------
   SI44649      OSP-INCORROUT PRTPEXRPT truncates Cycles Per Instruction
   SI38404      OSP-MSGC2M3003 T/QVPESVGN PRTPEXRPT
   SI54203      OSP-INCORROUT STRPEX error messages
   SI49885      OSP-INCORROUT PEX *FORMAT2 Activation Group Events
   SI49885      OSP-MSGCPFAF02 V7R1 CRTPEXDTA fails with V6R1 MGTCOL
   SI48889      OSP-INCORROUT CHGPEXDFN with PMCO events
   SI46839      OSP-INCORROUT Base function to enable future extensions
   SI41738      OSP-OTHER Base Function to Enable Future Extensions
   SI41391      OSP-OTHER PEX Support for PMCO Format 4 event
   SI39771      OSP-INCORROUT PEX Internal Data
   SI38465      OSP-INCORROUT Incorrect data in PEX file QAYPEPGFLT
   SI37984      OSP-INCORROUT PEX output field QRECN in file QAYPETBRKT is 0
   SI37735      OSP-INCORROUT PEX *MGTCOL  support enhancements

Summary Information

System.............................. i
Models..............................
Release............................. V7R1M0
Licensed Program............... 5770SS1
APAR Fixed.......................... View details for APAR SE60792
Superseded by:...................... View fix details for PTF SI60454
Recompile........................... N
Library............................. QSYS
MRI Feature ........................ NONE
Cum Level........................... C5142710


System i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information.

Document information

More support for: i family

Software version: V7R1M0

Operating system(s): OS/400

Reference #: SI55532