IBM Support

VM66738: CKV722I 08 DIAGNOSE E4 ERROR CODE 406 FOR RDEV CCUU CYLINDER 0 IS ALLOCATED AS DIRECTORY, PAGE, SPOOL, OR TDISK

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • CKV722I 08 Diagnose E4 error code 406 for RDEV ccuu cylinder 0
    is allocated as DIRECTORY, PAGE, SPOOL, or TDISK.
    
    The following message will also be seen:
    CKVECOLL: CKVCOLL program failed with rc=8 This is a serious
    error, please correct and rerun.
    

Local fix

  • To solve the issue of not being able to collect the real device
    information when cyl 0 is formatted as spool, page, or t-disk,
    this is an option:
    Define full-pack R/O minidisk overlays (or just cylinder 0
    overlays) in the CP-directory, and link them all into the userid
    that runs the collect, and then run CKVECOLL
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of zSecure Collect for z/VM.       *
    ****************************************************************
    * PROBLEM DESCRIPTION: zSecure Collect for z/VM might issue a  *
    *                      MSGCKV722I.                             *
    ****************************************************************
    * RECOMMENDATION: Apply the PTF provided and review the        *
    *                 documentation updates.                       *
    ****************************************************************
    When running CKVECOLL zSecure Manager for RACF z/VM v2.5.1 and
    cylinder 0 is has been allocated as DIRECTORY, PAGE, SPOOL, or
    TDISK, the collect will fail with error messages MSGCKV722I
    which begins with the text "Diagnose E4 error code 406 for
    RDEV ..." followed by a MSGCKVECOLL which begins with the text
    "CKVCOLL program failed with rc=8...".
    

Problem conclusion

  • zSecure Collect for z/VM has been modified, so that when running
    with the "COLLECT SENSE3990,ATTACH" option, a DEFINE MDISK
    command is used as fall back when cylinder 0 of the interrogate
    volume is allocated as PAGE or SPOOL, and the user running the
    zSecure Collect has CP class A (for the DEFINE command) and has
    CP option DEVMAINT or is the current system operator.
    Please note the documentation updates as provided by the APAR
    tracking comment data.
    

Temporary fix

Comments

APAR Information

  • APAR number

    VM66738

  • Reported component name

    TIV ZSECMGR-RAC

  • Reported component ID

    5655T1300

  • Reported release

    251

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-11-08

  • Closed date

    2023-11-14

  • Last modified date

    2023-11-30

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UV99444

Modules/Macros

  • CKVSYS
    

Fix information

  • Fixed component name

    TIV ZSECMGR-RAC

  • Fixed component ID

    5655T1300

Applicable component levels

  • R251 PSY UV99444

       UP23/11/14 P 2311