Error description
CKR0103 12 Field "PHRASEINT_PHRASEINT_EFFECTIVE" to be processed not found in any template at CKRCMDV2 line 6. This is seen when using RA.3.9.
Local fix
Exit the SYSTERM, edit COMMANDS and change: phraseint_phraseint_effective("Eff.") to: phraseint_effective("Eff.") then type GO on the command line.
Problem summary
**************************************************************** * USERS AFFECTED: Users of zSecure Audit for RACF 2.5.0 * * exploiting USREDATA report(Display and * * action on profiles with USERDATA) in * * interactive mode (option RA.3.9). * **************************************************************** * PROBLEM DESCRIPTION: zSecure Audit issues a MSGCKR0103 and * * terminates. * **************************************************************** * RECOMMENDATION: Apply the PTF provided. * **************************************************************** When user runs USERDATA report in interactive mode, the zSecure Audit issues a MSGCKR0103 which begins with the text "Field 'PHRASEINT_PHRASEINT_EFFECTIVE' to be processed not found..." and terminates.
Problem conclusion
zSecure Audit has beend modified, so that when the user runs the USERDATA report in interactive mode no message is issued and report is generated correctly.
Temporary fix
Comments
APAR Information
APAR number
OA66120
Reported component name
ZSEC BASE,ADMIN
Reported component ID
5655T0100
Reported release
250
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-02-12
Closed date
2024-02-19
Last modified date
2024-03-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ94672
Modules/Macros
CKRP3R26
Fix information
Fixed component name
ZSEC BASE,ADMIN
Fixed component ID
5655T0100
Applicable component levels
R250 PSY UJ94672
UP24/02/22 P F402
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSPQTM","label":"IBM Security zSecure Admin"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"250","Line of Business":{"code":"LOB24","label":"Security Software"}}]
Document Information
Modified date:
04 April 2024