IBM Support

Upgrade VSEESA270, Subset CICS/B0P

  Preventive Service Planning

Upgrade VSEESA270, Subset CICS/B0P


Upgrade VSEESA270, Subset CICS/B0P:

This subset contains installation information for CICS/VSE
Version 1, Release 1, Modification 1.


Change Summary

DATE LAST CHANGED SECTION 1. 06/11/17 INSTALLATION INFORMATION 2. YY/MM/DD DOCUMENTATION CHANGES NO ENTRIES 3. YY/MM/DD GENERAL INFORMATION NO ENTRIES 4. 07/12/03 GENERAL INFORMATION 5. YY/MM/DD CROSS PRODUCT DEPENDENCIES NO ENTRIES


Service Recommendation Summary

DATE APAR PTF VOLID COMMENTS 12 07/12/03 PK45073 UK31552 1000 HIPER RESTRICTION OF 1 RECEIVE 11 07/05/02 PK37353 UK24146 1000 HIPER TRANSACTION CWBG WAIT 10 06/11/16 PK31953 UK19656 1000 HIPER MULTIPLE COPIES OF DLZNUC 9 06/09/19 PK23631 UK17995 1000 HIPER DFHPC0405 ABEND APTM 8 06/07/04 PK21191 UK15924 1000 HIPER DFHZC2410 AND DFHZC3424 7 05/10/10 PK09460 UK07656 1000 HIPER MSG4936I FOLLOWED BY 6 05/08/24 PK06621 UK06434 1000 HIPER LOOP IN DFHEIP DURING 5 04/09/24 PQ94052 UQ93066 1000 HIPER DFHSM0102 0D11 DFHSMMF 4 03/12/23 PQ81688 UQ83240 1000 HIPER DFHSM0133 DFHSM0102 BRVSXA 3 03/11/26 PQ79655 UQ82471 1000 HIPER DFHSM0133 IN ECDSA FROM 2 03/11/20 PQ76257 UQ82178 1000 HIPER AFTER CANCELLING AND 1 03/04/24 PQ69381 UQ75840 1000 HIPER 3270 WEB BRIDGE ROLLUP


Installation Information

This section contains changes to the product's Program Directory. The following action(s) are required if you install PTFs from the SERVICE RECOMMENDATIONS section of this SUBSET: 4. 06/11/17 -------------------------------------------------------------- *** Action: UK19656 The Global and Local Catalogs will need to be deleted, redefined and initialized to allow the changes, introduced by this PTF, to be effective. APPLICABLE LEVEL: B0P 3. 05/08/29 ITEM DELETED 09/29/2005 2. 03/11/21 ------------------------------------------------------------------ *** Action: UQ82178 This PTF affects DFHIRP which must reside in the SVA. After this PTF is applied, DFHIRP must be re-loaded into the SVA before the changes in this PTF will take effect. NOTE:- If more than one release of CICS is installed on this system, the DFHIRP which is loaded into the SVA must be the DFHIRP from the highest CICS release. Please refer to the CICS TRANSACTION SERVER FOR VSE/ESA SYSTEM DEFINITION GUIDE for advice on loading CICS modules into the SVA. APPLICABLE LEVEL: B0P 1. 03/08/19 ----------------------------------------------------------------- *** Action: UQ75840 This fix changes macro DFHWBTLG, the BMS map to HTML template generator. In order to benefit from the change to the macro, you should rerun the assembly step that specifies SYSPARM(TEMPLATE), to regenerate your HTML templates from the BMS map source. *** Action: UQ75840 This APAR includes the facility to send templates generated from BMS maps which are larger than 32k. When using this facility, the temporary storage queue specified in the TCPIPSERVICE definition, or defaulted to DFHWEB, must not be recoverable. ---------------- ABOVE COMMENT ADDED BY PQ69381 -------------- *** Action: UQ75840 TO MAKE THE CHANGES IMPLEMENTED BY THIS APAR EFFECTIVE, THE US WILL NEED TO RUN A DFHCSDUP UPGRADE USING(DFHCURDM). *** Action: UQ75840 This fix changes DFHMDF, the BMS map field definition macro. In order to benefit from the change to the macro, you should rerun the assembly step that specifies SYSPARM(TEMPLATE), to regenerate your HTML templates from the BMS map source. ---------------- ABOVE COMMENT ADDED BY PQ48401 -------------- *** Action: UQ75840 This fix changes macro DFHWBTLG, the BMS map to HTML template generator. In order to benefit from the change to the macro, you should rerun the assembly step that specifies SYSPARM(TEMPLATE), to regenerate your HTML templates from the BMS map source. ---------------- ABOVE COMMENT ADDED BY PQ50151 -------------- *** Action: UQ75840 This PTF allows BMS applications to modify field attributes dynamically in the application program. In order to take advantage of this feature, it is necessary to regenerate all HTML templates that have been created from BMS maps. When the templates are recreated, the HTML table cells containing fields from the BMS map will no longer contain HTML The values will have been replaced by 3 symbols. The symbol names consist of a common prefix in the form Frrcccllll_ where the 'F' and the underscore (_) are constants, 'rr' is a 2 digit number representing the row, 'ccc' is a 3 digit number representing the column and 'llll' is a 4 digit number representing the length of the field. Two of the symbols will end in the strings PRE and SUF respectively and the third symbol will contain as much of the BMS field name as can fit into 21 characters. Any manual customization which was applied to the original template will need to be re-applied. ---------------- ABOVE COMMENT ADDED BY PQ60964 -------------- *** Action: UQ75840 The Global and Local Catalogs will need to be deleted, redefined and initialized to allow the changes, introduced by this PTF, to be effective. *** Action: UQ75840 After applying this PTF, module DFHXFP will automatically be loaded on every CICS startup. Before this PTF, DFHXFP was only ever loaded if ISC=YES was coded in the the SIT. DFHXFP is approximately 24K in length and is loaded into the CICS DSA below 16M. If your CICS DSA is constrained below 16M, you should consider increasing the value on your DSALIM SIT parameter in those regions which have ISC=NO in the SIT. ---------------- ABOVE COMMENT ADDED BY PQ66744 -------------- APPLICABLE LEVEL: B0P


Documentation Changes

This section outlines major errors in the product's published documentation. 1. YY/MM/DD NO ENTRIES


General Information

This section contains general information, i.e. SYSGEN hints/tips. 1. YY/MM/DD NO ENTRIES


Service Recommendations

12 07/12/03 PROBLEM: (PK45073) RESTRICTION OF 1 RECEIVE SESSION BE IMPOSED IN THE SESSION DEFINITION WHEN THE PROTOCOL SPECIFIED IS EXCI. USERS AFFECTED: All CICS users. RECOMMENDATION: INSTALL UK31552 ON VOLID 1000 (RB0P ) 11 07/05/02 PROBLEM: (PK37353) TRANSACTION CWBG WAIT FOREVER STATE CAUSES SHUTDOWN TO HANG USERS AFFECTED: All. RECOMMENDATION: INSTALL UK24146 ON VOLID 1000 (RB0P ) 10 06/11/16 PROBLEM: (PK31953) MULTIPLE COPIES OF DLZNUC BEING LOADED. USERS AFFECTED: All. RECOMMENDATION: INSTALL UK19656 ON VOLID 1000 (RB0P ) 9 06/09/19 PROBLEM: (PK23631) DFHPC0405 ABEND APTM ISSUED WHILE PROCESSING AEIV TRANSACTION CEMS. USING RCF FEATURE BROWSING REPORT HITTING PF11 THEN PF5 USERS AFFECTED: All CICS Users. RECOMMENDATION: INSTALL UK17995 ON VOLID 1000 (RB0P ) 8 06/07/04 PROBLEM: (PK21191) DFHZC2410 AND DFHZC3424 WILL BE FOLLOWED BY LOOP ON DFHZC3437 AND DFHZC2467.INVALID COMMUNICATION ID CID . USERS AFFECTED: All CICS Users. RECOMMENDATION: INSTALL UK15924 ON VOLID 1000 (RB0P ) 7 05/10/10 PROBLEM: (PK09460) MSG4936I FOLLOWED BY DFHSR0613 WHEN ATTEMPTING TO WRITE A JOURNAL RECORD WITH A BEFFER SIZE OF 32760. USERS AFFECTED: All RECOMMENDATION: INSTALL UK07656 ON VOLID 1000 (RB0P ) 6 05/08/24 PROBLEM: (PK06621) LOOP IN DFHEIP DURING HANDLE ABEND. COBOL AND LE DRIVE_GOTO CONTINUES TO CALL DFHEIP, CAUSING THE LOOP TO OCCUR. USERS AFFECTED: All RECOMMENDATION: INSTALL UK06434 ON VOLID 1000 (RB0P ) 5 04/09/24 PROBLEM: (PQ94052) DFHSM0102 0D11 DFHSMMF EMER EMERGENCY RESTART STARTUP CHECK ZONE DFHRUP USERS AFFECTED: All CICS users with UQ86779 applied. RECOMMENDATION: INSTALL UQ93066 ON VOLID 1000 (RB0P ) 4 03/12/23 PROBLEM: (PQ81688) DFHSM0133 DFHSM0102 BRVSXA SUBPOOL GROWS, LEADS TO SOS. STORAGE VIOLATION DETECTED BY DFHSMAR. USERS AFFECTED: All RECOMMENDATION: INSTALL UQ83240 ON VOLID 1000 (RB0P ) 3 03/11/26 PROBLEM: (PQ79655) DFHSM0133 IN ECDSA FROM GETMAIN REQUEST FROM DFHDBP1$ FOR BFT STORAGE. USERS AFFECTED: All. RECOMMENDATION: INSTALL UQ82471 ON VOLID 1000 (RB0P ) 2 03/11/20 PROBLEM: (PQ76257) AFTER CANCELLING AND RESTARTING A TOR DUE TO A HANG, THE MRO CONNECTIONS TO THE AOR REGIONS WERE NOT RECOVERED. USERS AFFECTED: All CICS Users. RECOMMENDATION: INSTALL UQ82178 ON VOLID 1000 (RB0P ) 1 03/04/24 PROBLEM: (PQ69381) 3270 WEB BRIDGE ROLLUP USERS AFFECTED: All CICS users with UQ69745. RECOMMENDATION: INSTALL UQ75840 ON VOLID 1000 (RB0P )


Cross Product Dependencies

This section contains information that is dependent upon another product other than this subset ID. It also contains information dealing with migration and product coexistance. 1. YY/MM/DD INTERDEPENDENT PRODUCT: PROBLEM: USERS AFFECTED: RECOMMENDATION: INSTALL XXXXXXX ON VOLID XXXX


Informational / Documentation


PTF / APAR Reference Lists

PTF Include List
UK06434 UK07656 UK15924 UK17995 UK19656 UK24146 UK31552 UQ75840 UQ82178 UQ82471 UQ83240 UQ93066
PTF Exclude List
PE APAR List
PQ73753


End of Upgrade VSEESA270 , Subset CICS/B0P , as of 2016/11/30.