Fixes are available
Fix Pack 5.1.1.0 (December 2012) for Tivoli Storage Productivity Center
Fix Pack 5.1.1.2 (September 2013) for Tivoli Storage Productivity Center
Fix Pack 5.1.1.5 (July 2014) for Tivoli Storage Productivity Center
Fix Pack 5.1.1.6 (March 2015) for Tivoli Storage Productivity Center
Fix Pack 5.1.1.9 (October 2015) for Tivoli Storage Productivity Center
Fix Pack 5.1.1.12 (October 2016) for Tivoli Storage Productivity Center
Fix Pack 5.1.1.13 (February 2017) for Tivoli Storage Productivity Center
Fix Pack 5.1.1.14 (June 2017) for Tivoli Storage Productivity Center
Fix Pack 5.1.1.15 (Sept 2017) for Tivoli Storage Productivity Center
Fix Pack 5.1.1.8 (July 2015) for Tivoli Storage Productivity Center
APAR status
Closed as program error.
Error description
After upgrading to TPC 5.1, the changepasswords tool will not launch. The path referenced is not correct for the new TPC installation.
Local fix
Edit the script and replace TPC_DIR_VALUE string with the TPC installation directory(C:\Program Files\IBM\TPC or /opt/IBM/TPC) Specify your directory if you have chosen something different.
Problem summary
**************************************************************** * USERS AFFECTED: * * All users that upgrade from TPC 4.x to TPC 5.1 on all * * platforms. * **************************************************************** * PROBLEM DESCRIPTION: * * C:\Program Files\IBM\TPC\service\changepasswords.bat * * (/opt/IBM/TPC/service/changepasswords.sh) cannot be launched * * after upgrading to TPC 5.1. It fails with the message * * "The system cannot find the path specified." * **************************************************************** * RECOMMENDATION: * * Edit C:\Program Files\IBM\TPC\service\changepasswords.bat * * (or /opt/IBM/TPC/service/changepasswords.sh) and replace * * TPC_DIR_VALUE with the TPC installation directory.(e.g. * * C:\Program Files\IBM\TPC) * ****************************************************************
Problem conclusion
The local fix is to edit C:\Program Files\IBM\TPC\service\changepasswords.bat (or /opt/IBM/TPC/service/changepasswords.sh) and replace TPC_DIR_VALUE with the TPC installation directory.(e.g. C:\Program Files\IBM\TPC).<br/><br/>The fix for this APAR is targeted for the following maintenance package:<br/><br/>| fix pack | 5.1.1-TIV-TPC-FP0001 - target March 2013<br/><br/>http://www-01.ibm.com/support/docview.wss?&uid =swg21320822<br/><br/>The target dates for future fix packs do not represent a formal <br/>commitment by IBM. The dates are subject to change without <br/>notice.
Temporary fix
Comments
APAR Information
APAR number
IC86739
Reported component name
TPC
Reported component ID
5608TPC00
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-09-24
Closed date
2012-10-23
Last modified date
2012-10-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
UPGRADE
Fix information
Fixed component name
TPC
Fixed component ID
5608TPC00
Applicable component levels
R510 PSY
UP
Document Information
Modified date:
23 March 2022