SUBJECT: APAR NUMBER: PJ27115
REFERENCE: AREA: LOCK MANAGEMENT
SEGMENT: CLMHH0 - RELEASE: HPO (Assembler)
Pre-requisite APARs are:
FOR SEGMENT CLMHH0 (Assembler) - REL HPO
PJ25094
To be applied in the order listed for each segment.
ABSTRACT OF PROBLEM
___________________
POSTC ERRCODE parameter coded incorrectly.
COMMENTS ON PROBLEM
___________________
In segment CLMH a POSTC call had an ERRCODE parameter erro-
neously coded as ERRCODE=R0. This generated incorrect code
because ERRCODE register input parameter should be coded as
ERRCODE=(R0).
SOLUTION
________
Segment CLMH was modified to correct the POSTC ERRCODE param-
eter.
DEPENDENCIES
____________
Related Segments Affected By This APAR.
_______________________________________
Segments to be assembled or compiled:
None
Segments to be link edited:
None
Load Modules to be loaded:
None
Migration Considerations
========================
None
-- END APAR PJ27115