SUBJECT:         APAR  NUMBER: PJ27115

REFERENCE:  AREA:     LOCK MANAGEMENT
            SEGMENT:  CLMHH0     - RELEASE:  HPO   (Assembler)


Pre-requisite APARs are:
FOR SEGMENT CLMHH0     (Assembler) - REL HPO
 PJ25094  
To be applied in the order listed for each segment.

ABSTRACT OF PROBLEM
___________________
POSTC ERRCODE parameter coded incorrectly.


COMMENTS ON PROBLEM
___________________
In  segment  CLMH  a  POSTC  call had an ERRCODE parameter erro-
neously coded  as  ERRCODE=R0.  This  generated  incorrect  code
because  ERRCODE  register  input  parameter  should be coded as
ERRCODE=(R0).


SOLUTION
________
Segment CLMH was modified to correct the  POSTC  ERRCODE  param-
eter.

DEPENDENCIES
____________

Related Segments Affected By This APAR.
_______________________________________

Segments to be assembled or compiled:
None

Segments to be link edited:
None

Load Modules to be loaded:
None

Migration Considerations
========================
None



-- END APAR PJ27115