7014-T42 IBM Rack Model T42

IBM Asia Pacific Sales Manual
Revised:  November 21, 2017.

Table of contents
TOC Link Product life cycle dates TOC Link Publications
TOC Link Abstract TOC Link Features
TOC Link Highlights TOC Link Accessories
TOC Link Description TOC Link Machine elements
TOC Link Models TOC Link Supplies
TOC Link Technical description  

 
Product life cycle dates
Type Model Announced Available Marketing Withdrawn Service Discontinued
7014-T42 2000/05/092000/08/04 - -

Back to topBack to top
 
Abstract

IBM Power Systems and earlier UNIX systems consisting of the IBM System p5, IBM eServer pSeries and IBM RS/6000 product lines provide great value. These innovative systems feature IBM's leading-edge technology and run the top-rated operating systems of AIX, IBM i and Linux. This broad product line ranges from powerful workstations to mission-critical symmetric multiprocessing (SMP) servers for ERP, SCM, CRM, transaction processing, web serving; demanding scientific and technical computing and business intelligence tasks. These platforms provide the power to create change and the flexibility to manage it, with thousands of applications that provide real value.

Model abstract 7014-T42

The IBM 7014 Rack Model T42 is a 2.0 meter rack that will address the special requirements of customers who want a enclosure to house their equipment. The T42 provides 42 EIA units (42U) of usable space. Because of its height, special shipping and handling procedures may be required in some cases.

The T42 is compatible with the #0553 19-inch rack and compatible with past racks used such as the Model R00/S00 and RS/6000 racks. Features include:

  • 42 EIA units (42U) of usable space
  • Optional removable side panels
  • Front door options - standard or acoustic, or a trim kit for easy access
  • Optional side to side mounting hardware for joining multiple racks
  • Increased power distribution and weight capacity
  • Standard black or optional white color
  • Rear door - standard or acoustic

Back to topBack to top
 
Highlights

See Model Highlights.

Model highlights 7014-T42

  • Taller, stronger 19-inch wide racks provide increased height, weight, and power distribution capacity for IBM Power Systems, IBM System p5, IBM eServer pSeries, and IBM RS/6000 product lines.
  • 2.0 meter Model T42 capacity is 42U (EIA units).
  • Optional features include front door, removable side panels, and side to side joining of multiple racks into suites.
  • Optional ruggedized rack feature provides added earthquake protection with modular rear brace, concrete floor bolt down hardware, and bolt-in steel front filler panels.
  • Available in standard black color.
  • Model T42 supports AC configurations only.
  • Regular or acoustic door options

Back to topBack to top
 
Description

The 2.0 meter 7014-T42 rack has 42 EIA units (42U) of vertical mounting space for 19-inch drawers. An EIA unit is an industry standard for indicating vertical mounting space in a rack, where 1U equals 44.45 mm (1.75 in). This rack meets the Electronics Industries Association EIA-310-D standard. The standard color is black.

Side Panels and Side To Side Rack Suite Attachment

The rack side panels are optional, and can be quickly installed or removed from the outside of the rack, with no tools required. This design allows a row of racks without side panels to be bolted together in a continuous suite, using the optional side to side rack connecting hardware. When multiple racks are joined in this way, cables can be easily run between racks without having to exit the continuous rack enclosure. A small gap is maintained between the two adjacent racks, which is filled by three matching steel trim pieces that snap into place on the front, top, and rear, between each rack. The trim pieces cover the space between each rack for an enhanced appearance and for additional protection of the equipment inside the racks. Side panels are needed only for the two end racks of the suite. The same removable side panels are used for both the Model T00 and Model T42 racks. On T42 racks, there are additional side covers for the portion of the rack that extends above 1.8 meters.

Front Door and Front Trim Kit

The optional front door has an appearance that is consistent with the S80 and other current RS/6000 Enterprise Systems. The main surface is steel, with a perforated hole pattern that is designed to provide the required ventilation and sufficient visibility of indicator lights for equipment installed inside the rack. Each rack must be ordered with either a front door or a front trim kit (but not both). The front trim kit consists of steel parts that snap into the front of the rack at the left, right, and top edges. They are painted to match the overall rack color and present an attractive appearance that is consistent with the RS/6000 brand image. Because the T42 rack is taller than the T00 rack, the front doors, front trim kits, and side to side rack connecting kits require different sets of features for the two models.

Ruggedized Rack Feature

For enhanced rigidity and stability of the rack, the optional Ruggedized Rack Feature provides additional hardware that reinforces the rack and anchors it to the floor. This hardware is designed primarily for use in locations where earthquakes are a concern. The feature includes a large steel brace that bolts into the rear of the rack. It is hinged on the left side so it can swing out of the way for easy access to the rack drawers when necessary. The Ruggedized Rack Feature also includes hardware for bolting the rack to a concrete floor, and bolt-in steel filler panels for any unoccupied spaces in the rack.

Rear Door Heat Exchanger for 7014-T42

The IBM Rear Door Heat Exchanger is an effective way to assist your AC system in keeping your datacenter cool. It removes heat generated by the systems in the rack before the heat enters the room, allowing your air conditioning unit to handle increasingly dense system deployments. It may also offer a convenient way to handle dangerous "hot spots" in your data center.

Inside the door of the heat exchanger, sealed tubes filled withcirculating chilled water effectively remove up to 55% of the heat generated in a fully populated rack and dissipate it so it is not released into the data center. In fact, the heat exchanger can remove up to 15 kW (approximately 50,000 BTUs/hr) of heat generated by a full server rack, based on total rack output.

The heat exchanger can be easily installed by customers and moved to different 7014-T42 racks to address changing cooling requirements. Its unique design uses standard fittings and couplings and, because there are no moving or electrical parts, helps increase reliability. It can be opened like any rear cover, so serviceability of racks fitted with a heat exchanger is as easy as a standard air cooled rack.

Other Standard Equipment and Optional Features

Each rack is shipped with standard equipment that includes a rear door, front and rear anti-tilt plates, four leveling feet, snap-in filler panels for any unoccupied rack space, and an AC power distribution unit (PDU) mounted inside the rack in an area that is separate from the drawer mounting area. There is room for up to 4 PDU's without using any of the rack's 42U capacity. The rack drawer mounting area is centered relative to the two sides of the rack, which provides ample room to route cables within the frame on both the left and right sides. There are numerous anchor points formed into the frame where cables can be tied down for strain relief.

On site, temporary 6U height reduction capability

The top 6U of the rack can be temporarily detached at the client site to make it easier to move the rack through doors or elevators. The top 6U is then reattached to the rack frame to provide the full 42U rack capacity. The rack is approximately 11 inches (~28 cm) shorter with the top removed. See the IBM KnowledgeCenter about "removing the rack top cover".

https://www.ibm.com/support/knowledgecenter/TI0002C/p8hbf/t42rackc overrem ove.htm

Note: The weight of the rack top cover is about 63 pounds (~29kg).
Back to topBack to top
 

Models

Model summary matrix

Model    Capacity
-----    ---------------------------------------
 T42     42 EIA units of vertical mounting space
 

Customer setup (CSU)

These products are designated Customer Setup.

Devices supported

None

Model conversions

None
Back to topBack to top
 

Technical description
TOC Link Physical specifications TOC Link Operating environment TOC Link Limitations
TOC Link Hardware requirements TOC Link Software requirements


This 2.0 meter rack has 42 EIA units of vertical mounting space for 19-inch mounting-width drawers. The standard rack comes with an AC power distribution unit rear-mounted in an area that is separate from the drawer mounting area.

  • Common Specify Codes: Specify these feature numbers on all T42 System Rack orders:
    • Power Cord (specify feature number for country)
    • Language Group (specify feature number for country)

    AC Power Distribution Unit

    Specify one of these features numbers in the T42 system rack order if you plan to use it with the standard AC power distribution unit:

    • Feature number 9171 -- Power Distribution Unit -- Base, Single Phase
    • Feature number 9173 -- Power Distribution Unit -- Base, Two Of Three Phase

Physical specifications

Physical Specifications Rack Model T42:

  • Width:
    • 644 mm (25.4 in) with side panels
    • 623 mm (24.5 in) without side panels
  • Depth:
    • 1098 mm (43.3 in) with front and rear doors, (Feature 6083 or 6069)
    • 1147 mm (45.2 in) with front and rear doors, (Feature 6089)
    • 1042 mm (41.0 in) with rear door only
  • Height: 2015 mm (79.3 in) with standard AC power
  • Empty Weight: 261 kg (575 lb)

Operating environment

  • Temperature: 10 to 40 degrees C
  • Relative Humidity: 8% to 80%
  • Maximum Wet Bulb: 27 degrees C
  • Sound Power: None

Power Requirements:

Rack Model T42

  • Operating Voltage: 200 to 240 V AC 50/60 Hz
  • Power Source Loading: 4.8 KVA per PDU (rack may have up to 4 PDU's)

The rack power distribution system provides 200 to 240 V AC (50Hz/60Hz) to the system components (drawers). Each Power Distribution Unit (PDU) is capable of providing up to 4.8 KVA.

EMC Conformance Classification:

This equipment is subject to FCC rules; it will comply with the appropriate FCC rules before final delivery to the buyer or center of distribution.

  • USA: FCC Class A
  • Germany: IOP
  • Europe: CISPR A
  • Japan: VCCI-1

EMC Conformance:

Taiwan BCIQ CNS13438 (Taiwan EMC Standard)

Homologation: Telecom Environmental Testing (Safety and EMC)

Homologation approval for specific countries has been initiated with the IBM Homologation and Type Approval (HT&A) organization in LaGaude, France.

The 7014 and applicable features meet the environmental testing requirements of the country TELECOM and have been designed and tested in compliance with the Full Quality Assurance Approval (FQAA) process as delivered by the British Approval Board for Telecom (BABT), the UK Telecom Regulatory authority.

General Requirements

This product complies with the IBM Corporate Bulletin C-B 0-2594-000 Statement of Conformity of IBM Product to External Standard (Suppliers Declaration).

Product Safety/Country Testing/Certification

  • US: UL
  • Canada: CNL (CSA or CUL)
  • Germany/Europe: GS Mark (Safety, TUV, EN60 950)

The following information must be entered per Energy Saving Law - Japan, Program Requirements Number N-B 1-9174-001.

Power Requirements

  • Power Consumption in active mode: 0 watts
  • Power Consumption in energy savings mode: 0 watts

Limitations

Models T42:

  • Each rack must be ordered with either a front door or a trim kit. A rack can not have both a front door and a trim kit.
  • A rack must not have a side panel installed where it is joined to an adjacent rack with the rack suite attachment kit. A suite of racks with a quantity of N racks joined together would typically require a quantity of N-1 rack suite attachment kits and two side panels to cover the two ends of the suite of racks.
  • Rack suite attachment kits are intended for joining two racks of equal height. Joining a T00 rack to a T42 rack is not recommended. If this is done, the bolts and spacers will function correctly, but the trim pieces are not designed for use with uneven rack heights.
  • Front doors are not available on white racks.
  • There are twelve AC power outlets on each Power Distribution Unit (PDU) (#9188 and #7188). A maximum of twelve drawers can be installed in a rack that has a single #9188 or #7188 PDU.
  • More than six drawers can be installed when space is available in the rack if additional PDU's (#6171 or #6173) are installed.
  • If one or more racks are ordered, all drawers in that multisystem order must be mounted in those racks. (Unmounted drawers must have separate multisystem orders.)
  • Two IBM 3490 Model F11s can share an 8-EIA space in the rack (order one placement code for each pair of units).
  • Two IBM 3590 Model B11s or E11s may share a 12-EIA space in the rack (order one placement code for each pair of units).
  • Many 3490 and 3590 tape libraries may interfere with the front door of a T42 rack. When planning for the installation of this type of equipment, racks should be ordered without a front door.
  • The available Uninterruptable Power Supply (9910-U33) requires one of the following features (#6171, #6173, #9171, or #9173) for each 9910-U33 installed.
  • A maximum of 42 EIA units are available for mounting drawers in the rack.
  • Maximum Weight of Drawers is 667 kg (1470 lb)
  • The T42 rack requires special handling because of its height. If a system is ordered with a 42U rack, it can not be shipped by air, and two additional days will be required for shipping. Requested arrival dates should be adjusted accordingly, i.e., the system will typically arrive two days later than the calculated arrival date (CAD). Site planning should be done in advance to assure that the rack will fit under any low doorways at the customer location.
  • The factory will install drawers only in the lower 32-EIA units of the Model T42 rack. Installation of drawers in the upper 10-EIA units must be done at the customer's location.
  • The T42 rack is designed to hold up to 4 Power Distribution Units vertically mounted in the back of the rack, two each on the left and right sides. Up to 3 additional PDUs can be installed horizontally in the rear of the rack, in the space that is normally used for rack-mounted drawers. Each horizontally mounted PDU occupies 1U of space in the rack, and therefore reduces the space available for mounting servers and other components.
  • If PDU features 7177 or 9177 are ordered, the Power Cord Specify feature must be 9823.
  • If the rack is required to support redundant power system modules, a second PDU (#7188 or #7109) should be ordered.

Rack-integrated system with Expansion Drawer

Regardless the rack-integrated system to which the PCIe Gen3 I/O Expansion Drawer is attached to, if the Expansion Drawer is ordered as factory integrated, the PDUs in the rack will be defaulted to be placed horizontally to enhance cable management.

Expansion Drawers complicate the access to vertical PDUs if located at the same height. IBM recommends accommodating PDUs horizontally on racks containing one or more PCIe Gen3 I/O Expansion Drawers.

Once the rack with Expansion Drawers is delivered to the customer, the customer is allowed to rearrange the PDUs from horizontal to vertical. However, the configurator will remain considering the PDUs are placed horizontally for the matter of calculating the free space still available in the rack.

Vertical PDUs can be used only if CSRP (#0469) is on the order. When specifying CSRP, the customer will provide the locations where the PCIe Gen3 I/O Expansion Drawers must be placed, avoiding locating those adjacent to Vertical PDU locations, EIA 6 through 16 and 21 through 31

Hardware requirements

Supported PDU Combinations for 7014 Models T00 and T42

Each 7014-T00 or 7014-T42 rack is shipped with one of the available base PDU features. The choice of which initial PDU is ordered for the rack will determine which additional PDU features may be ordered for the rack, either in the original rack order or in a later MES order. The following chart shows the allowable PDU combinations within a single T00 or T42 rack.

              ------------------------------------------------ 
                     Allowable Optional/Additional PDUs        
              ------ ------ ------ ------ ------ ------ ------ 
               6171   6173   6174   7176   7177   7178   7188  
============= ====== ====== ====== ====== ====== ====== ====== 
        9171    X                    M(1)   M(2)               
        ----- ------ ------ ------ ------ ------ ------ ------ 
   B    9173           X                           M+          
   A    ----- ------ ------ ------ ------ ------ ------ ------ 
   S    9174                  X                    M           
   E    ----- ------ ------ ------ ------ ------ ------ ------ 
        9176                         X                         
   P    ----- ------ ------ ------ ------ ------ ------ ------ 
   D    9177                                X                  
   U    ----- ------ ------ ------ ------ ------ ------ ------ 
        9178                                       X           
        ----- ------ ------ ------ ------ ------ ------ ------ 
        9188                                              X    
 -----  ----- ------ ------ ------ ------ ------ ------ ------ 
 
9188 as the last row for BASE PDU 7188 Allowable Optional/Additional PDUs
  • X = Supported combination for initial or MES orders
  • M = Supported combination for MES orders only
  • (1) For all line cords except feature #9823
  • (2) Required for line cord feature #9823
  • + 3-phase 16A (not 2 of 3 phase and 32A like feature #9173)

Software requirements

Not applicable
Back to topBack to top
 

Publications

Model T00 and T42 Rack Installation and Service Guide (SA38-0577) is shipped with the products.
Back to topBack to top
 

Features
TOC Link Features - No charge TOC Link Features - Chargeable TOC Link Feature availability matrix
TOC Link Feature descriptions


Features - No charge

  • LANGUAGES
    • (#9300) - Language Group Specify - US English
    • (#9703) - Language Group Specify - French
    • (#9704) - Language Group Specify - German
    • (#9705) - Language Group Specify - Polish
    • (#9707) - Language Group Specify - Portuguese
    • (#9708) - Language Group Specify - Spanish
    • (#9711) - Language Group Specify - Italian
    • (#9712) - Language Group Specify - Canadian French
    • (#9714) - Language Group Specify - Japanese
    • (#9716) - Language Group Specify - Korean
    • (#9719) - Language Group Specify - Hungarian
    • (#9720) - Language Group Specify - Slovakian
    • (#9721) - Language Group Specify - Russian
    • (#9722) - Language Group Specify - Simplified Chinese (PRC)
  • POWER
    • (#9171) - Power Distribution Unit Specify - Base/Side Mount, Single Phase
    • (#9173) - Power Distribution Unit Specify - Base/Side Mount, Two Of Three Phase
    • (#9176) - Power Distribution Unit Specify - Base/Side Mount, Single Phase, L6-30 Connector
    • (#9177) - Power Distribution Unit Specify - Base/Side Mount, Single Phase, IEC-309 Connector
    • (#9178) - Power Distribution Unit Specify - Base/Side Mount, Three Phase, IEC-309 Connector
    • (#9188) - Power Distribution Unit Specify - Base/Side Mount, Universal, UTG0247 Connector
  • LINECORDS
    • (#9800) - Power Cord Specify - United States/Canada
    • (#9801) - Power Cord Specify - Raised Floor (US)
    • (#9822) - Power Cord Specify - Australia
    • (#9823) - Power Cord Specify - EMEA (PDU)
    • (#9824) - Power Cord Specify - Japan and 60HZ AP
    • (#9826) - Power Cord Specify - New Zealand
    • (#9835) - Power Cord Specify - Korea (PDU)
    • (#9986) - Power Cord Specify - Chicago (1.8M)(6 FT.)
    • (#9987) - Power Cord Specify - Chicago (Raised Floor)
  • MISCELLANEOUS
    • (#0050) IBM Express Seller Indicator
    • (#0710) - Balanced Warehouse Solution
    • (#1114) - Smart Analytics System routing indicator
    • (#5001) - Customer Service Specify
    • (#9002) - Field Integration Indicator, Ship Empty Rack
    • (#9461) -Month Indicator
    • (#9462) -Day Indicator
    • (#9463) -Hour Indicator
    • (#9464) -Minute Indicator
  • SPECIFY CODES
    • (#0127) - Rack Content Specify: 7026/H70 - 8EIA
    • (#0128) - Rack Content Specify: 7026/H80 - 5EIA
    • (#0129) - Rack Content Specify: 7026/M80 - 8EIA
    • (#0147) - Rack Content Specify: 3590/B11 - (2 x B11 = 12EIA)
    • (#0149) - Rack Content Specify: UPS/MOD - 4EIA
    • (#0156) - Rack Content Specify: 7133/D40 - 4EIA
    • (#0162) - Rack Content Specify: 7337/306 - 5EIA
    • (#0165) - Rack Content Specify: 2104/DL1 - 3EIA
    • (#0169) - Rack Content Specify: 3490/F11 - 4EIA
    • (#0170) - Rack Content Specify: 3570/C11 - 6EIA
    • (#0171) - Rack Content Specify: 3590/E11 - (1X OR 2X = 12EIA)
    • (#0172) - Rack Content Specify: 3570/C12 - 6EIA
    • (#0173) - Rack Content Specify: Secondary I/O Drawer, AC Power - 5EIA
    • (#0175) - Rack Content Specify: 3 EIA
    • (#0176) - Rack Content Specify: Primary I/O Drawer, - 5EIA
    • (#0178) - Rack Content Specify: 7026/B80 -- 5 EIA
    • (#0179) - Rack Content Specify: 2104/DU3 - 3EIA
    • (#0180) - Rack Content Specify: 2108/G07 - 2EIA
    • (#0181) - Rack Content Specify: 2109/S08 - 1EIA
    • (#0182) - Rack Content Specify: 2109/S16 - 2EIA
    • (#0183) - Rack Content Specify: 9910/A30 - 5EIA
    • (#0184) - Rack Content Specify: 9910/A31 - 5EIA
    • (#0185) - Rack Content Specify: 9910/P60 - 6EIA
    • (#0186) - Rack Content Specify: 9910/P61 - 6EIA
    • (#0187) - Rack Content Specify: #6606 -- 3EIA (9910 UPS Battery Module)
    • (#0188) - Rack Content Specify: 7026/6H1 - 5EIA
    • (#0189) - Rack Content Specify: 7026/6M1 - 8EIA (CEC Drawer)
    • (#0194) - Rack Content Specify: 3590/A60 - 9U
    • (#0195) - Rack Content Specify: 7038/6M2 - 8U
    • (#0196) - Rack Content Specify: 7311/D10 - (2 x D10 = 4U)
    • (#0197) - Rack Content Specify: 7028-6C1 -- 5 EIA
    • (#0198) - Rack Content Specify: 9910/P33 - 2U
    • (#0199) - Rack Content Specify: #6607 on 9910-P33 - 2U
    • (#0200) - Rack Content Specify: 9910/B38 - 4U
    • (#0201) - Rack Content Specify: #6621 on 9910-B38 - 2U
    • (#0202) - Rack Content Specify: 7315/CR2 - 1U
    • (#0203) - Rack Content Specify: 7026/6H0 - 5U (EIA)
    • (#0206) - Rack Content Specify: 7028/6C4 - 4U
    • (#0207) - Rack Content Specify: 7029/6C3 - 4U
    • (#0208) - Rack Content Specify: 2109/F16 - 1EIA
    • (#0210) - Rack Content Specify: 7311/D20 - 4U
    • (#0213) - Rack Content Specify: 3542/2RU - 3EIA (FAST T200)
    • (#0214) - Rack Content Specify: 3552/1RU - 4EIA (FAST T500)
    • (#0215) - Rack Content Specify: 3560/1RU - 3EIA (FAST EXP500)
    • (#0216) - Rack Content Specify: 1 EIA
    • (#0217) - Rack Content Specify: 3542/2RX - 3EIA (FAST T200 EMEA)
    • (#0218) - Rack Content Specify: 9910/P18 - 2U
    • (#0219) - Rack Content Specify: FC #6606 on 9910-P18 - 2U
    • (#0220) - Rack Content Specify: 1742/1RU - 4EIA
    • (#0221) - Rack Content Specify: 1740/1RU - 3EIA
    • (#0222) - Rack Content Specify: 1742/90U - 4EIA
    • (#0223) - Rack Content Specify: 3590/H11 - 12EIA
    • (#0224) - Rack Content Specify: 9910/M15 - 1U
    • (#0225) - Rack Content Specify: 9910/M30 - 2U
    • (#0226) - Rack Content Specify: FC #3401 on 9910-M30 - 2U (9910 UPS Battery Module)
    • (#0228) - Rack Content Specify: 7311/D11 - (2 x D11 = 4U)
    • (#0229) - Rack Content Specify: 9111/520 - 4U
    • (#0230) - Rack Content Specify: 9113/550 - 4U
    • (#0231) - Rack Content Specify: 9117/570/MMA/MMB, 8234-EMA - 4U
    • (#0232) - Rack Content Specify: 9117/570/MMA/MMB, 8234-EMA - 8U
    • (#0241) - Rack Content Specify: 9117/570/MMA/MMB - 12U
    • (#0242) - Rack Content Specify: 9117/570/MMA/MMB - 16U
    • (#0249) - Rack Content Specify: 7031-D24-4U
    • (#0252) - Rack Content Specify: 7315/CR3 - 1U
    • (#0255) - Rack Content Specify: 9110/510 - 2 EIA
    • (#0256) - Rack Content Specify: 7314-G30 - 4 EIA
    • (#0257) - Rack Content Specify: 9131-52A - 4U
    • (#0258) - Rack Content Specify: 9133-55A - 4U
    • (#0259) - Rack Content Specify: 9115/505 - 1U
    • (#0260) - Rack Content Specify: 9116/561 - 4U
    • (#0261) - Rack Content Specify: 9116/561 - 8U
    • (#0262) - Rack Content Specify: 7310/CR4 - 1U
    • (#0263) - Rack Content Specify FC 5886 - 2EIA
    • (#0269) - Rack Content Specify: 7048-120 - 1 EIA
    • (#0270) - Rack Content Specify: 7048-270 - 6 EIA
    • (#0275) - Rack Content Specify: 1815/80A, 1818/53A - 4EIA (AC, 2 Line Cords)
    • (#0284) - Rack Content Specify: 7042-CR4 - 1U
    • (#0286) - Rack Content Specify for 7042/CR5
    • (#0298) -Rack Content Specify: 8202-E4B - 4U
    • (#0299) -Rack Content Specify: 8205-E6B -- 4U
    • (#0303) - RACK SPECIFY FC 5802
    • (#0315) - Rack Content Specify: 7036-P16 - 1U
    • (#0316) - Rack Content Specify: 9110-51A - 2U
    • (#0317) - Rack Content Specify: 7037-A50 - 5U
    • (#0320) - Rack Content Specify: 9910-E82/E83- 6 EIA
    • (#0321) - Rack Content Specify: 9910-E82/E83 -FC 6646/6646 Battery Module 3 EIA
    • (#0324) - Rack Content Specify: 7042-CR6/CR7/CR8/CR9 - 1EIA
    • (#0331) - Rack Content Specify: 7874-024 - 1U
    • (#0332) - Rack Content Specify: 7874-040 - 4U
    • (#0334) - Rack Content Specify: 7874-120 - 7U
    • (#0335) - Rack Content Specify: 7874-240 - 14U
    • (#0336) - Rack Content Specify 3572/SH3/SH4 - 1EIA
    • (#0337) - Rack Content Specify: 9910-E50 - 3U
    • (#0338) - Rack Content Specify: 9910-E50 with Feature 6648
    • (#0339) - Rack Content Specify, 1818-RS2, 1818-RS3
    • (#0340) - Rack Content Specify: 2498-B40/B24/F48 SAN Switch
    • (#0361) - Rack Content Specify 5 EIA for FC 0595
    • (#0363) -2EIA Rack Content Specify
    • (#0364) - Rack Content Specify, Juniper EX4200 Switch
    • (#0370) -Rack Content Specify: 8231-E2B -- 2U
    • (#0379) -Rack Content Specify: 7874-036 - 1U
    • (#0380) -Rack Content Specify: 7874-072 - 5U
    • (#0381) -Rack Content Specify: 7874-324 - 14U
    • (#0703) - Solution Indicator
    • (#0704) - HA Solution Indicator
    • (#9169) - Order Routing Indicator - System Plant

COLOR: Black. A specify code is not required.

VOLTAGE: A specify code for voltage/power is required and will be provided by the configurator based on the country code of the order. Specify codes must be used when an alternative to the ELINK configurator default is required.

LANGUAGE: A specify code is not required. Language will be determined by the plant based on the country code of the order. Specify codes must be used when an alternative to the plant country default is required.

Features - Chargeable

Special Features - Initial Orders

  • Administrative
    • (#EGSA) -IDEA Solution Specify
    • (#EGSB) -SOLUTION SPECIFY
    • (#EGSC) -GL2 SOLUTION SPEC 2TB DCS370E
    • (#EGSD) -GL4 SOLUTION SPEC 2TB DCS370E
    • (#EGSE) -GL6 SOLUTION SPEC 2TB DCS370E
    • (#EGSF) -GL2 SOLUTION SPEC 4TB DCS370E
    • (#EGSG) -GL4 SOLUTION SPEC 4TB DCS370E
    • (#EGSH) -GL6 SOLUTION SPEC 4TB DCS370E
    • (#EGSJ) -GS1 SOLUTION SPEC 400GB #EL1S
    • (#EGSK) -GS1 SOLUTION SPEC 800GB #EL1S
    • (#EGSL) -GS2 SOLUTION SPEC 400GB #EL1S
    • (#EGSM) -GS2 SOLUTION SPEC 800GB #EL1S
    • (#EGSN) -GS2 SOLUTION SPEC 1.2TB #EL1S
    • (#EGSP) -GS4 SOLUTION SPEC 400GB #EL1S
    • (#EGSQ) -GS4 SOLUTION SPEC 800GB #EL1S
    • (#EGSR) -GS4 SOLUTION SPEC 1.2TB #EL1S
    • (#EGSS) -GS6 SOLUTION SPEC 1.2TB #EL1S
    • (#EGT4) -GL2 SOLUTION SPEC 6TB DCS370E
    • (#EGT5) -GL4 SOLUTION SPEC 6TB DCS370E
    • (#EGT6) -GL6 SOLUTION SPEC 6TB DCS370E
    • (#EHP1) -OpenPower HPC Specify Code
    • (#ESC0) -S&H - No Charge
    • (#ESC1) -Rack S&H-a
  • Miscellaneous
    • (#0711) -IBM mCommerce Application Solution Indicator
    • (#0712)- Manufacturing Routing Code for CSC
    • (#9465) -Qty Indicator
    • (#9466) -Countable Member Indicator
    • (#ECS0) -Indicator Assembled and Tested in China
    • (#ECSM) -Custom Service Specify, Mexico
    • (#ECSP) -Custom Service Specify, Poughkeepsie, USA
    • (#ECSS) -Integrated Solution Packing
    • (#EHJ0) -Administrative Tracking
    • (#EHLA) -IBM Data Engine for Hadoop Solution Specify
    • (#EHLS) -ESS Next Gen Flash solution specify
    • (#ESSC) -ESS 2U24 STORAGE SOLUTION SPECIFY
    • (#ESSD) -ESS GS1S Solution Specify (3.84TB SSD) - 92 TB Raw Disk Capacity
    • (#ESSE) -ESS GS1S SOLUTION SPECIFY (15.36TB SSD) - 368 TB Raw Disk Capacity
    • (#ESSF) -ESS GS2S SOLUTION SPECIFY (3.84TB SSD) - 184 TB Raw Disk Capacity
    • (#ESSG) -ESS GS2S SOLUTION SPECIFY (15.36TB SSD) - 737 TB Raw Disk Capacity
    • (#ESSK) -ESS GS4S SOLUTION SPECIFY (3.84TB SSD) - 368 TB Raw Disk Capacity
    • (#ESSL) -ESS GS4S SOLUTION SPECIFY (15.36TB SSD) - 1474 TB Raw Disk Capacity
  • POWER
    • (#5889) - Intelligent PDU+, base option, 1 EIA Unit, Universal, UTG0247 Connector
    • (#EPAF) -HVDC PDU - 90A 6xOutlet Alternate Base
    • (#EPAG) -Power Distribution Unit (US) - 1 EIA Unit, Universal, Fixed Power Cord
    • (#EPTG) -High Function 9xC19 PDU: Switched, Monitoring (option with new 7014)
    • (#EPTK) -High Function 9xC19 PDU 3-Phase: Switched, Monitoring (option with new 7014)
    • (#EPTM) -High Function 12xC13 PDU: Switched, Monitoring (option with new 7014)
    • (#EPTP) -High Function 12xC13 PDU 3-Phase: Switched, Monitoring (option with new 7014)
  • RACK RELATED
    • (#4651) - Rack Indicator, Rack #1
    • (#4652) - Rack Indicator, Rack #2
    • (#4653) - Rack Indicator, Rack #3
    • (#4654) - Rack Indicator, Rack #4
    • (#4655) - Rack Indicator, Rack #5
    • (#4656) - Rack Indicator, Rack #6
    • (#4657) - Rack Indicator, Rack #7
    • (#4658) - Rack Indicator, Rack #8
    • (#4659) - Rack Indicator, Rack #9
    • (#4660) - Rack Indicator, Rack #10
    • (#4661) - Rack Indicator, Rack #11
    • (#4662) - Rack Indicator, Rack #12
    • (#4663) - Rack Indicator, Rack #13
    • (#4664) - Rack Indicator, Rack #14
    • (#4665) - Rack Indicator, Rack #15
    • (#4666) - Rack Indicator, Rack #16
    • (#6088) - Front Door for 1.8 Meter Rack (Sculptured Black)
    • (#6089) - Front Door for 2.0 Meter Rack (Sculptured Black)
    • (#6257) -Rack Extender
    • (#6546) - White Rack Option, Factory Only
    • (#ERGC) -Ruggedized Rack Feature, Extra Strength
    • (#ERGD) -Rack Doors for 2M Ruggedized Rack
  • SPECIFY CODES
    • (#0204) - Rack Content Specify: 2104/DS4 - 3EIA
    • (#0205) - Rack Content Specify: 3592/J1A/E05 - 10EIA
    • (#0227) - Rack Content Specify: 3592/J70 - 7EIA
    • (#0234) - Rack Content Specify: 1710/10U, 1812/81A, 1818/D1A - 3EIA (DASD EXP)(AC, 2 Cords)
    • (#0235) - Rack Content Specify: 1722/60U - 3EIA
    • (#0236) - Rack Content Specify: 9910/P65 - 3EIA
    • (#0243) - Rack Content Specify: 9910/P30 - 2EIA
    • (#0244) - Rack Content Specify: 9910/P30 Battery Module - 2EIA
    • (#0245) - Rack Content Specify: 9910/P64 - 5EIA
    • (#0246) - Rack Content Specify: 9910 Feature Number 6641 (9910-P64/P65 Battery Module) - 3EIA
    • (#0247) - Rack Content Specify: 7310/CR2 - 1U
    • (#0250) - Rack Content Specify: 9124/720 - 4U
    • (#0251) - Rack Content Specify: 9123/710 - 2EIA
    • (#0253) - Rack Content Specify: 7310/CR3 1U
    • (#0254) - Rack Content Specify: 1724-100 or 1814-70A/72A -- 3EIA
    • (#0274) - Rack Content Specify: 7214-1U2 - 1 EIA unit
    • (#0278) - Rack Content Specify: 8203-E4A - 4U
    • (#0288) - Rack Content Specify: 8204-E8A - 4U
    • (#0322) - Rack Content Specify: 3580/H3L/H3S - 2U
    • (#0323) - Rack Content Specify: 5887-2U
    • (#0326) - Rack Content Specify: 3580/L33/L43/S43 - 3U
    • (#0327) - Rack Content Specify: 3573/L2U - 2U
    • (#0328) - Rack Content Specify: 3573/L4U - 4U
    • (#0343) - Rack Content Specify: 3576/L5B - 5U
    • (#0345) - Rack Content Specify: 3576/E9U - 9U
    • (#0346) - Rack Content Specify: 3577/L5U -5U
    • (#0388) -Rack Content Specify, Juniper EX4500 Switch
    • (#0389) -Rack Content Specify, Switch Network Documentation Drawer
    • (#0390) -Rack Content Specify, DS3500 Storage Drawer
    • (#0392) -Rack Content Specify: 8246-Lxx
    • (#0458) -Rack Content Specify: 5888-1U
    • (#0469) -Customer Specified Rack Placement
    • (#9459) -PDU/PWR and Power Cord Redundancy Assurance
    • (#ERLR) -Left/Right PDU Redundancy
    • (#ER00) -Custom Soln Center Services per PRPQ 8A2064
    • (#ER02) -Rack Content Specify: 8408-E8D
    • (#ER03) -Rack Content Specify: 2076-224 - 2U
    • (#ER04) -Rack Content Specify: 2076-124 - 2U
    • (#ER07) -Rack Content Specify: 1611-16E 1EIA (BINGO)
    • (#ER08) -Rack Content Specify: 1455-24E/7120-24E
    • (#ER09) -Rack Content Specify: 1455-48E
    • (#ER0A) -Rack Content Specify: 1455-64C
    • (#ER0B) -Rack Content Specify: 1455-48T
    • (#ER0C) -Rack Content Specify: 1455-64F
    • (#ER0D) -Rack Content Specify: 9109-RMD
    • (#ER0E) -Rack Content Specify: 7316-TF4 -- 1 EIA
    • (#ER0H) -Rack Content Specify: 8248-L4T
    • (#ER0J) -Rack Content Specify: 8412-EAD
    • (#ER0M) -Rack Content Specify for #EMX0 I/O Expansion Drawer
    • (#ER0T) -Rack Content Specify 8286-41A/42A - 4EIA
    • (#ER0U) -Rack Content Specify: 8284-22A - 2EIA
    • (#ER0V) -Rack Content Specify: 8247/5148-22L - 2EIA
    • (#ER0Y) -Rack Content Specify: 8412-EAD
    • (#ER0Z) -Rack Content Specify: 8247-42L - 4EIA
    • (#ER10) -Rack Content Specify first enclosure: 9119-MHE, 9119-MME - 7 EIA
    • (#ER11) -Rack Content Specify second enclosure: 9119-MHE, 9119-MME - 12 EIA
    • (#ER12) -Rack Content Specify third enclosure: 9119-MHE, 9119-MME - 17 EIA
    • (#ER13) -Rack Content Specify fourth enclosure: 9119-MHE, 9119-MME - 22 EIA
    • (#ER14) -Rack Content Specify 1U Horizontal PDU - 1 EIA EIA
    • (#ER15) -Rack Content Specify reserve 1U rack space for PDU
    • (#ER17) -Rack Content Specify: 8408-E8E
    • (#ER18) -Rack Content Specify: 5148/8247-21L - 2EIA
    • (#ER19) -RACK SPECIFY FC EMX0
    • (#ER1B) -Rack Content Specify: Reserve 1U Rack Space at Bottom of Rack
    • (#ER1D) -Rack Content Specify: 8831-NF2
    • (#ER1F) -FlashSystem 9840/9843 - 2 E1A
    • (#ER1H) -Rack Content Specify: 8831-F36
    • (#ER1L) -Rack Content Specify: 8408-44E
    • (#ER1P) -Rack Content Specify: 8348-21C 2EIA
    • (#ER1T) -Rack Content Specify: Reserve 1U Rack Space at Top of Rack
    • (#ER1U) -Rack content specify 5147-1F2 3EIA
    • (#ER1V) -Rack Content Specify: 8831-S52 1EIA
    • (#ER24) -Rack Content Specify: 8335-GCA 2EIA
    • (#ER25) -Rack Content Specify: 8335-GTA 2EIA
    • (#ER26) -Rack Content Specify: 8867-FM1/FM2 1EIA
    • (#ER28) -Rack Content Specify 8335 - GTB 2EIA
    • (#ER2B) -Rack Content Specify: Reserve 2U Rack Space at Bottom of Rack
    • (#ER2T) -Rack Content Specify: Reserve 2U Rack Space at Top of Rack
    • (#ER30) -Rack Content Specify: 8284-21A - 2EIA
    • (#ERC0) -Rack Content Specify EXP12SX #ESLL/#ELLL 2-EIA/2U
    • (#ERC1) -Rack Content Specify EXP24SX #ESLS/#ELLS 2-EIA/2U
    • (#ERC2) -Rack Content Specify 7063-CR1
    • (#ESS0)- ESS Seagate Solution Specify
    • (#ESS1)- ESS GL2S Solution Specify (4TB HDD) - 664 TB Raw Disk Capacity
    • (#ESS2)- ESS GL2S Solution Specify (8TB HDD) - 1328 TB Raw Disk Capacity
    • (#ESS3)- ESS GL2S Solution Specify (10TB HDD) - 1660 TB Raw Disk Capacity
    • (#ESS4)- ESS GL4S Solution Specify (4TB HDD) - 1336 TB Raw Disk Capacity
    • (#ESS5)- ESS GL4S Solution Specify (8TB HDD) - 2672 TB Raw Disk Capacity
    • (#ESS6)- ESS GL4S Solution Specify (10TB HDD) - 3340 TB Raw Disk Capacity
    • (#ESS7)- ESS GL6S Solution Specify (4TB HDD) - 2008 TB Raw Disk Capacity
    • (#ESS8)- ESS GL6S Solution Specify (8TB HDD) - 4016 TB Raw Disk Capacity
    • (#ESS9)- ESS GL6S Solution Specify (10TB HDD) - 5020 TB Raw Disk Capacity
  • Services
    • (#5524) -RFID TAGS FOR SERVERS, BLADES, BLADECENTERS, RACKS, AND HMCS

Special Features - Plant and/or Field Installable

  • Administrative
    • (#B0LG) -ServicePac Not Selected
    • (#B0LH) -Service Renewal Requested
    • (#B0UW) -SP WAMO 3Y 24x7 SD
  • CABLES
    • (#4691) - Rack Status Beacon Cable, Junction Box To Drawer Or Status Beacon
    • (#4692) - Rack Status Beacon Cable, Junction Box Daisy Chain
  • LINECORDS
    • (#6442) - Power Cord, 7176/9176 PDU To Wall, 9800/9824 Equivalent
    • (#6443) - Power Cord, 7176/9176 PDU To Wall, 9801 Equivalent
    • (#6444) - Power Cord, 7176/9176 PDU To Wall, 9822 Equivalent
    • (#6445) - Power Cord, 7177/9177 PDU To Wall, 9823 Equivalent
    • (#6447) - Power Cord, 7176/9176 PDU To Wall, 9826 Equivalent
    • (#6448) - Power Cord, 7176/9176 PDU To Wall, 9835 Equivalent
    • (#6449) - Power Cord, 7176/9176 PDU To Wall, 9986 Equivalent
    • (#6450) - Power Cord, 7176/9176 PDU To Wall, 9987 Equivalent
    • (#6489) - Power Cord, 7188/9188 PDU To Wall, 4.3M, 24A, IEC 309 3P+N+G 32A Plug
    • (#6491) - 4.3m (14-Ft) 1PH/63A 200-240V Power Cord P+N+G 63A Plug
    • (#6492) - Power Cord, 7188/9188 PDU To Wall, 4.3M, 48A, IEC 309 2P+G 60A Plug
    • (#6653) - Power Cord, 7188/9188 PDU To Wall, 4.3M, 16A, IEC 309 3P+N+G 16A Plug
    • (#6654) - Power Cord, 7188/9188 PDU To Wall, 4.3M, 24A, NEMA L6-30 Plug
    • (#6655) - Power Cord, 7188/9188 PDU To Wall, 4.3M, 24A, RS 3750DP (Watertight) Plug
    • (#6656) - Power Cord, 7188/9188 PDU To Wall, 4.3M, 24A, IEC 309 P+N+G 32A Plug
    • (#6657) - 4.3m (14-Ft) 1PH/32A Power Cord
    • (#6658) - Power Cord, 7188/9188 PDU To Wall, 4.3M, 24A, Korean Plug
    • (#6667) -4.3m (14-Ft) 3PH/32A Pwr Cd-Australia
  • MISCELLANEOUS
    • (#1140) -Custom Service Specify, Rochester Minn, USA
    • (#6586) - Modem Tray For 19-Inch Rack
    • (#ECSC) -Custom Service Specify, Shenzhen, China
    • (#ECSF) -Custom Service Specify, Montpellier, France
    • (#ECSJ) -NeuCloud Indicator/Specify
    • (#EDAN) -Analytics Data Node Add-on
    • (#EGTH) -GL2 (12U) SOLUTION SPECIFY (WITH 7.2K HDD 8TB + DCS3700e)
    • (#EGTJ) -GL4 (20U) SOLUTION SPECIFY (WITH 7.2K HDD 8TB + DCS3700e)
    • (#EGTK) -GL6 (28U) SOLUTION SPECIFY (WITH 7.2K HDD 8TB + DCS3700e)
  • POWER
    • (#6171) - Power Distribution Unit - Side Mount, Single Phase
    • (#6173) - Power Distribution Unit - Side Mount, Two Of Three Phase
    • (#7109) - Intelligent PDU+, 1 EIA Unit, Universal, UTG0247 Connector
    • (#7176) - Power Distribution Unit - Side Mount, Single Phase, L6-30 Connector
    • (#7177) - Power Distribution Unit - Side Mount, Single Phase, IEC-309 Connector
    • (#7178) - Power Distribution Unit - Side Mount, Three Phase, IEC-309 Connector
    • (#7188) - Power Distribution Unit - Side Mount, Universal, UTG0247 Connector
    • (#EPAA) -HVDC PDU - 90A 6xOutlet
    • (#EPTJ) -High Function 9xC19 PDU: Switched, Monitoring
    • (#EPTL) -High Function 9xC19 PDU 3-Phase: Switched, Monitoring
    • (#EPTN) -High Function 12xC13 PDU: Switched, Monitoring
    • (#EPTQ) -High Function 12xC13 PDU 3-Phase: Switched, Monitoring
  • RACK RELATED
    • (#4690) - Rack Status Beacon
    • (#4693) - Rack Status Beacon Junction Box
    • (#6069) - Front Door For 2.0 Meter Rack (High Perforation)
    • (#6080) - Ruggedized Rack Feature
    • (#6081) - Front Trim Kit For 2.0 Meter Rack (Black)
    • (#6082) - Front Trim Kit For 2.0 Meter Rack (White)
    • (#6083) - Front Door For 2.0 Meter Rack (Black)
    • (#6084) - Front Door For 2.0M OEM Rack (Black)
    • (#6086) - Suite Attach Kit For 2.0 Meter Rack (Black)
    • (#6087) - Suite Attach Kit For 2.0 Meter Rack (White)
    • (#6095) - Power Cord for PDU to External I/O Device
    • (#6098) - Side Panel For 1.8 or 2.0 Meter Rack (Black)
    • (#6099) - Side Panel For 1.8 Or 2.0 Meter Rack (White)
    • (#6238) -High-end Appearance Side Covers
    • (#6246) - Thin Profile Front Trim Kit For 1.8 Meter Rack (Black)
    • (#6247) - Thin Profile Front Trim Kit For 2.0 Meter Rack (Black)
    • (#6249) - Acoustic Rack Doors, Front and Rear, 2.0 M
    • (#6250) - High-End Appearance Front Door
    • (#6272) - 2.0m Rack Trim Kit
    • (#6858) - Rear Door Heat Exchanger for 7014-T42
    • (#7118) -Environmental Monitoring Probe
    • (#EB3Z) -Lift tool based on GenieLift GL-8 (standard)
    • (#EBA5) -HVDC PDU Horizontal Mounting
    • (#EC07) -Slim Rear Acoustic Door
    • (#EC08) -Slim Front Acoustic Door
    • (#EPTH) -Horizontal PDU Mounting Hardware
    • (#ERG0) -Rack Rear Extension
    • (#ERG7) -Front Door for Power 770 & 780 2.0 Meter Rack (High Perforation)
    • (#ERGB) -Acoustic Black Front Door
  • Services
    • (#0010) -One CSC Billing Unit
    • (#0011) -Ten USC Billing Units
  • Specify Codes
    • (#ER29) -Rack Content Specify 5147-084 5EIA

Feature availability matrix

The following feature availability matrix for MT 7014 uses the letter "A" to indicate features that are available and orderable on the specified models. "S" indicates a feature that is supported on the new model during a model conversion; these features will work on the new model, but additional quantities of these features cannot be ordered on the new model; they can only be removed. "N" indicates that the feature is not supported on the new model and must be removed during the model conversion. As additional features are announced, supported, or withdrawn, this list will be updated. Please check with your Marketing Representative for additional information.

         T  A = AVAILABLE  S = SUPPORTED
         4  N = NOT SUPPORTED, MUST BE REMOVED
         2 
           
FEAT/PN            DESCRIPTION
-------- - -----------------------------------------
0010     A  One CSC Billing Unit
0011     A  Ten USC Billing Units
0050     A  IBM Express Seller Indicator
0127     A  Rack Content Specify: 7026/H70 - 8EIA
0128     A  Rack Content Specify: 7026/H80 - 5EIA
0129     S  Rack Content Specify: 7026/M80 - 8EIA
0147     A  Rack Content Specify: 3590/B11 - (2 x B11 = 12EIA)
0149     A  Rack Content Specify: UPS/MOD - 4EIA
0156     A  Rack Content Specify: 7133/D40 - 4EIA
0162     A  Rack Content Specify: 7337/306 - 5EIA
0165     S  Rack Content Specify: 2104/DL1 - 3EIA
0169     A  Rack Content Specify: 3490/F11 - 4EIA
0170     A  Rack Content Specify: 3570/C11 - 6EIA
0171     A  Rack Content Specify: 3590/E11 - (1X OR 2X = 12EIA)
0172     A  Rack Content Specify: 3570/C12 - 6EIA
0173     A  Rack Content Specify: Secondary I/O Drawer, AC Power - 5EIA
0175     S  Rack Content Specify: 3 EIA
0176     A  Rack Content Specify: Primary I/O Drawer, - 5EIA
0178     A  Rack Content Specify: 7026/B80 -- 5 EIA
0179     A  Rack Content Specify: 2104/DU3 - 3EIA
0180     A  Rack Content Specify: 2108/G07 - 2EIA
0181     A  Rack Content Specify: 2109/S08 - 1EIA
0182     A  Rack Content Specify: 2109/S16 - 2EIA
0183     A  Rack Content Specify: 9910/A30 - 5EIA
0184     A  Rack Content Specify:  9910/A31 - 5EIA
0185     A  Rack Content Specify:  9910/P60 - 6EIA
0186     A  Rack Content Specify:  9910/P61 - 6EIA
0187     A  Rack Content Specify:  #6606 -- 3 EIA (9910 UPS
                 Battery Module)
0194     A  Rack Content Specify:  3590/A60 - 9U
0195     A  Rack Content Specify:  7038/6M2 - 8U
0196     A  Rack Content Specify:  7311/D10 - (2 x D10 = 4U)
0197     A  Rack Content Specify:  7028-6C1 -- 5 EIA
0198     A  Rack Content Specify:  9910/P33 - 2U
0199     A  Rack Content Specify:  #6607 on 9910-P33 - 2U
0200     A  Rack Content Specify:  9910/B38 - 4U
0201     A  Rack Content Specify:  #6621 on 9910-B38 - 2U
0202     A  Rack Content Specify:  7315/CR2 - 1U
0203     A  Rack Content Specify:  7026/6H0 - 5U (EIA)
0204     A  Rack Content Specify:  2104/DS4 - 3EIA
0205     A  Rack Content Specify:  3592/J1A/E05 - 10EIA
0206     A  Rack Content Specify:  7028/6C4 - 4U
0207     A  Rack Content Specify:  7029/6C3 - 4U
0208     A  Rack Content Specify:  2109/F16 - 1EIA
0210     A  Rack Content Specify:  7311/D20 - 4U
0213     A  Rack Content Specify:  3542/2RU - 3EIA (FAST T200)
0214     A  Rack Content Specify:  3552/1RU - 4EIA (FAST T500)
0215     A  Rack Content Specify:  3560/1RU - 3EIA (FAST EXP500)
0216     A  Rack Content Specify:  1 EIA
0217     A  Rack Content Specify:  3542/2RX - 3EIA (FAST T200 EMEA)
0218     A  Rack Content Specify:  9910/P18 - 2U
0219     A  Rack Content Specify:  FC #6606 on 9910-P18 - 2U
0220     A  Rack Content Specify:  1742/1RU - 4EIA
0221     A  Rack Content Specify:  1740/1RU - 3EIA
0222     A  Rack Content Specify:  1742/90U - 4EIA
0223     A  Rack Content Specify:  3590/H11 - 12EIA
0224     A  Rack Content Specify: 9910/M15 - 1U
0225     A  Rack Content Specify: 9910/M30 - 2U
0226     A  Rack Content Specify: 9910/FC 3401 - 2U
              (9910 UPS Battery Module)
0227     A  Rack Content Specify: 3592/J70 - 7EIA
0228     A  Rack Content Specify: 7311/D11 - (2 x D11 = 4U)
0229     A  Rack Content Specify:  9111/520 - 4U
0230     A  Rack Content Specify:  9113/550 - 4U
0231     S  Rack Content Specify: 9117/570/MMA/MMB, 8234-EMA - 4U
0232     S  Rack Content Specify: 9117/570/MMA/MMB, 8234-EMA - 8U
0234     A  Rack Content Specify: 1710/10U, 1812/81A, 1818/D1A - 3EIA
            (DASD EXP)(AC, 2 Cords)
0233     A  Rack Content Specify: 7316-TF3 - 1EIA
0235     A  Rack Content Specify: 1722/60U - 3EIA
0236     A  Rack Content Specify: 9910/P65 - 3EIA
0241     A  Rack Content Specify: 9117/570/MMA/MMB - 12U
0242     A  Rack Content Specify: 9117/570/MMA/MMB - 16U
0243     A  Rack Content Specify: 9910/P30 - 2EIA
0244     A  Rack Content Specify: 9910/P30 Battery Module - 2EIA
0245     A  Rack Content Specify: 9910/P64 - 5EIA
0246     A  Rack Content Specify: 9910 Feature Number 6641
               (9910-P64,P65 Battery Module) - 3EIA
0247     A  Rack Content Specify:  7310/CR2 - 1U
0249     A  Rack Content Specify:  7031-D24-4U
0250     A  Rack Content Specify:  9124/720 - 4U
0251     A  Rack Content Specify:  9123/710 - 2EIA
0253     A  Rack Content Specify:  7310/CR3 - 1U
0254     A  Rack Content Specify: 1724-100 or 1814-70A/72A --
            3EIA
0255     A  Rack Content Specify:  9110/510 - 2EIA
0256     A  Rack Content Specify:  7314-G30 - 4EIA
0257     A  Rack Content Specify:  9131-52A - 4U
0258     A  Rack Content Specify:  9133-55A - 4U
0259     A  Rack Content Specify:  9115/505 - 1U
0260     A  Rack Content Specify:  9116/561 - 4U
0261     A  Rack Content Specify:  9116/561 - 8U
0262     S  Rack Content Specify:  7310/CR4 - 1U
0263     A  Rack Content Specify FC 5886 - 2EIA
0269     A  Rack Content Specify:  7048-120 - 1 EIA
0270     A  Rack Content Specify:  7048-270 - 6 EIA
0274     A  Rack Content Specify:  7214-1U2 - 1 EIA unit
0275     A  Rack Content Specify:  1815/80A, 1818/53A - 4EIA (AC, 2 Line
            Cords)
0278     A  Rack Content Specify: 8203-E4A - 4U
0284     S  Rack Content Specify:  7042-CR4 - 1U
0286     A  Rack Content Specify for 7042/CR5
0288     A  Rack Content Specify:  8204-E8A - 4U
0297     A  Rack Content Specify: 8233-E8B - 4U
0298     A  Rack Content Specify: 8202-E4B - 4U
0299     S  Rack Content Specify: 8205-E6B -- 4U
0303     A  RACK SPECIFY FC 5802
0315     A  Rack Content Specify:  7036-P14 - 1U
0316     A  Rack Content Specify:  9110-51A - 2U
0317     A  Rack Content Specify:  7037-A50 - 5U
0320     S  Rack Content Specify: 9910-E82/E83- 6 EIA
0321     S  Rack Content Specify: 9910-E82/E83 -FC 6646/6646
            Battery Module 3 EIA
0322     A  Rack Content Specify:  3580/H3L/H3S - 2U
0323     A  Rack Content Specify: 5887-2U
0324     A  Rack Content Specify: 7042-CR6/CR7/CR8/CR9 - 1EIA
0326     A  Rack Content Specify:  3580/L33/L43/S43 - 3U
0327     A  Rack Content Specify:  3573/L2U - 2U
0328     A  Rack Content Specify:  3573/L4U - 4U
0331     A  Rack Content Specify: 7874-024 - 1U
0332     A  Rack Content Specify: 7874-040 - 4U
0334     A  Rack Content Specify: 7874-120 - 7U
0335     A  Rack Content Specify: 7874-240 - 14U
0336     A  Rack Content Specify 3572/SH3/SH4 - 1EIA
0337     S  Rack Content Specify: 9910-E50 - 3U
0338     S  Rack Content Specify: 9910-E50 with Feature 6648
0339     A  Rack Content Specify, 1818-RS2, 1818-RS3
0340     A  Rack Content Specify: 2498-B40/B24/F48 SAN Switch
0343     A  Rack Content Specify:  3576/L5B - 5U
0345     A  Rack Content Specify:  3576/E9U - 9U
0346     A  Rack Content Specify:  3577/L5U -5U
0361     A  Rack Content Specify 5 EIA for FC 0595
0363     A  2EIA Rack Content Specify
0364     A  Rack Content Specify, Juniper EX4200 Switch
0370     A  Rack Content Specify: 8231-E2B -- 2U
0379     A  Rack Content Specify: 7874-036 - 1U
0380     A  Rack Content Specify: 7874-072 - 5U
0381     A  Rack Content Specify: 7874-324 - 14U
0384     A  Rack Content Specify: 9179-MHB, 4U.
0385     A  Rack Content Specify: 9179-MHB, 8U.
0386     A  Rack Content Specify: 9179-MHB, 12U.
0387     A  Rack Content Specify: 9179-MHB, 16U.
0388     A  Rack Content Specify, Juniper EX4500 Switch
0389     A  Rack Content Specify, Switch Network Documentation
           Drawer
0390     A  Rack Content Specify, DS3500 Storage Drawer
0392     A  Rack Content Specify: 8246-Lxx
0458     A  Rack Content Specify: 5888-1U
0469     A  Customer Specified Rack Placement
0710     A  Balanced Warehouse Solution
0711     S  IBM mCommerce Application Solution Indicator
0712     A  Manufacturing Routing Code for CSC
1114     S  Smart Analytics System routing indicator
1140     A  Custom Service Specify, Rochester Minn, USA
4651     A  Rack Indicator, Rack #1
4652     A  Rack Indicator, Rack #2
4653     A  Rack Indicator, Rack #3
4654     A  Rack Indicator, Rack #4
4655     A  Rack Indicator, Rack #5
4656     A  Rack Indicator, Rack #6
4657     A  Rack Indicator, Rack #7
4658     A  Rack Indicator, Rack #8
4659     A  Rack Indicator, Rack #9
4660     A  Rack Indicator, Rack #10
4661     A  Rack Indicator, Rack #11
4662     A  Rack Indicator, Rack #12
4663     A  Rack Indicator, Rack #13
4664     A  Rack Indicator, Rack #14
4665     A  Rack Indicator, Rack #15
4666     A  Rack Indicator, Rack #16
4690     S  Rack Status Beacon
4691     S  Rack Status Beacon Cable, Junction Box To Drawer Or
                 Status Beacon
4692     S  Rack Status Beacon Cable, Junction Box Daisy Chain
4693     S  Rack Status Beacon Junction Box
5001     A  Customer Service Specify
5524     A  RFID TAGS FOR SERVERS, BLADES, BLADECENTERS, RACKS,
           AND HMCS
5889     A  Intelligent PDU+, base option, 1 EIA Unit,
             Universal, UTG0247 Connector
6069     A  Front Door For 2.0 Meter Rack (High Perforation)
6080     A  Ruggedized Rack Feature
6081     S  Front Trim Kit For 2.0 Meter Rack (Black)
6082     S  Front Trim Kit For 2.0 Meter Rack (White)
6083     S  Front Door For 2.0 Meter Rack (Black)
6084     A  Front Door For 2.0M OEM Rack (Black)
6086     A  Suite Attach Kit For 2.0 Meter Rack (Black)
6087     S  Suite Attach Kit For 2.0 Meter Rack (White)
6095     A  Power Cord for PDU to External I/O Device
6098     A  Side Panel For 1.8 or 2.0 Meter Rack (Black)
6099     A  Side Panel For 1.8 Or 2.0 Meter Rack (White)
6171     S  Power Distribution Unit - Side Mount, Single Phase
6173     S  Power Distribution Unit - Side Mount, Two Of Three Phase
6238     A  High-end Appearance Side Covers
6247     S  Thin Profile Front Trim Kit For 2.0 Meter Rack (Black)
6249     A  Acoustic Rack Doors, Front and Rear, 2.0 M
6250     S  High-End Appearance Front Door
6257     S  Rack Extender
6272     A  2.0m Rack Trim Kit
6442     S  Power Cord, 7176/9176 PDU To Wall, 9800/9824 Equivalent
6443     S  Power Cord, 7176/9176 PDU To Wall, 9801 Equivalent
6444     S  Power Cord, 7176/9176 PDU To Wall, 9822 Equivalent
6445     S  Power Cord, 7177/9177 PDU To Wall, 9823 Equivalent
6447     S  Power Cord, 7176/9176 PDU To Wall, 9826 Equivalent
6448     S  Power Cord, 7176/9176 PDU To Wall, 9835 Equivalent
6449     S  Power Cord, 7176/9176 PDU To Wall, 9986 Equivalent
6450     S  Power Cord, 7176/9176 PDU To Wall, 9987 Equivalent
6489     A  Power Cord, 7188/9188 PDU To Wall, 4.3M, 24A, IEC 309
                 3P+N+G 32A Plug
6491     A  4.3m (14-Ft) 1PH/63A 200-240V Power Cord
                 P+N+G 63A Plug
6492     A  Power Cord, 7188/9188 PDU To Wall, 4.3M, 48A, IEC 309
                 2P+G 60A Plug
6546     S  White Rack Option, Factory Only
6580     A  Rack Security Kit
6586     S  Modem Tray For 19-Inch Rack
6653     A  Power Cord, 7188/9188 PDU To Wall, 4.3M, 16A, IEC 309
                 3P+N+G 16A Plug
6654     A  Power Cord, 7188/9188 PDU To Wall, 4.3M, 24A, NEMA L6-30
                 Plug
6655     A  Power Cord, 7188/9188 PDU To Wall, 4.3M, 24A, RS 3750DP
                 (Watertight) Plug
6656     A  Power Cord, 7188/9188 PDU To Wall, 4.3M, 24A, IEC 309
                 P+N+G 32A Plug
6657     A  4.3m (14-Ft) 1PH/32A Power Cord
6658     A  Power Cord, 7188/9188 PDU To Wall, 4.3M, 24A, Korean Plug
6667     A  4.3m (14-Ft) 3PH/32A Pwr Cd-Australia
6858     A  Rear Door Heat Exchanger for 7014-T42
6860     A  Mounting hardware kit
7109     A  Intelligent PDU+, 1 EIA Unit, Universal, UTG0247
             Connector
7118     A  Environmental Monitoring Probe
7176     S  Power Distribution Unit - Side Mount, Single Phase, L6-30
                 Connector
7177     S  Power Distribution Unit - Side Mount, Single Phase,
                 IEC-309 Connector
7178     S  Power Distribution Unit - Side Mount, Three Phase,
                 IEC-309 Connector
7188     A  Power Distribution Unit - Side Mount, Universal, UTG0247
                 Connector
9002     A  Field Integration Indicator, Ship Empty Rack
9169     A  Order Routing Indicator - System Plant
9171     S  Power Distribution Unit Specify - Base/Side Mount, Single
                 Phase
9173     S  Power Distribution Unit Specify - Base/Side Mount, Two Of
                 Three Phase
9176     S  Power Distribution Unit Specify - Base/Side Mount, Single
                 Phase, L6-30 Connector
9177     S  Power Distribution Unit Specify - Base/Side Mount, Single
                 Phase, IEC-309 Connector
9178     S  Power Distribution Unit Specify - Base/Side Mount, Three
                 Phase, IEC-309 Connector
9188     A  Power Distribution Unit Specify - Base/Side Mount,
                 Universal, UTG0247 Connector
9300     A  Language Group Specify - US English
9459     A  PDU/PWR and Power Cord Redundancy Assurance
9461     A  Month Indicator
9462     A  Day Indicator
9463     A  Hour Indicator
9464     A  Minute Indicator
9465     A  Qty Indicator
9466     A  Countable Member Indicator
9703     A  Language Group Specify - French
9704     A  Language Group Specify - German
9705     A  Language Group Specify - Polish
9707     A  Language Group Specify - Portuguese
9708     A  Language Group Specify - Spanish
9711     A  Language Group Specify - Italian
9712     A  Language Group Specify - Canadian French
9714     A  Language Group Specify - Japanese
9716     A  Language Group Specify - Korean
9719     A  Language Group Specify - Hungarian
9720     A  Language Group Specify - Slovakian
9721     A  Language Group Specify - Russian
9722     A  Language Group Specify - Simplified Chinese (PRC)
9800     S  Power Cord Specify - United States/Canada
9801     S  Power Cord Specify - Raised Floor (US)
9822     S  Power Cord Specify - Australia
9823     S  Power Cord Specify - EMEA (PDU)
9824     S  Power Cord Specify - Japan and 60HZ AP
9826     S  Power Cord Specify - New Zealand
9835     S  Power Cord Specify - Korea (PDU)
9986     S  Power Cord Specify - Chicago (1.8M)(6 FT.)
9987     S  Power Cord Specify - Chicago (Raised Floor)
B0LG     S  ServicePac Not Selected
B0LH     S  Service Renewal Requested
B0UW     A  SP WAMO 3Y 24x7 SD
EB3Z     A  Lift tool based on GenieLift GL-8 (standard)
EBA5     A  HVDC PDU Horizontal Mounting
EC07     A  Slim Rear Acoustic Door
EC08     A  Slim Front Acoustic Door
ECS0     A  Indicator Assembled and Tested in China
ECSC     A  Custom Service Specify, Shenzhen, China
ECSF     A  Custom Service Specify, Montpellier, France
ECSJ     A  NeuCloud Indicator/Specify
ECSM     A  Custom Service Specify, Mexico
ECSP     A  Custom Service Specify, Poughkeepsie, USA
ECSS     A  Integrated Solution Packing
EDAN     A  Analytics Data Node Add-on
EGSA     A  IDEA Solution Specify
EGSB     A  SOLUTION SPECIFY
EGSC     S  GL2 SOLUTION SPEC 2TB DCS370E
EGSD     S  GL4 SOLUTION SPEC 2TB DCS370E
EGSE     S  GL6 SOLUTION SPEC 2TB DCS370E
EGSF     A  GL2 SOLUTION SPEC 4TB DCS370E
EGSG     A  GL4 SOLUTION SPEC 4TB DCS370E
EGSH     A  GL6 SOLUTION SPEC 4TB DCS370E
EGSJ     A  GS1 SOLUTION SPEC 400GB #EL1S
EGSK     A  GS1 SOLUTION SPEC 800GB #EL1S
EGSL     A  GS2 SOLUTION SPEC 400GB #EL1S
EGSM     A  GS2 SOLUTION SPEC 800GB #EL1S
EGSN     A  GS2 SOLUTION SPEC 1.2TB #EL1S
EGSP     A  GS4 SOLUTION SPEC 400GB #EL1S
EGSQ     A  GS4 SOLUTION SPEC 800GB #EL1S
EGSR     A  GS4 SOLUTION SPEC 1.2TB #EL1S
EGSS     A  GS6 SOLUTION SPEC 1.2TB #EL1S
EGTH     A  GL2 (12U) SOLUTION SPECIFY (WITH 7.2K HDD 8TB + DCS3700e)
EGTJ     A  GL4 (20U) SOLUTION SPECIFY (WITH 7.2K HDD 8TB + DCS3700e)
EGTK     A  GL6 (28U) SOLUTION SPECIFY (WITH 7.2K HDD 8TB + DCS3700e)
EGT4     A  GL2 SOLUTION SPEC 6TB DCS370E
EGT5     A  GL4 SOLUTION SPEC 6TB DCS370E
EGT6     A  GL6 SOLUTION SPEC 6TB DCS370E
EHJ0     A  Administrative Tracking
EHLA     A  IBM Data Engine for Hadoop Solution Specify
EHLS     S  ESS Next Gen Flash solution specify
EHP1     A  OpenPower HPC Specify Code
EPAA     A  HVDC PDU - 90A 6xOutlet
EPAF     A  HVDC PDU - 90A 6xOutlet Alternate Base
EPAG     A  Power Distribution Unit (US) - 1 EIA Unit, Universal,
            Fixed Power Cord
EPTG     A  High Function 9xC19 PDU: Switched, Monitoring (option
           with new 7014)
EPTH     A  Horizontal PDU Mounting Hardware
EPTJ     A  High Function 9xC19 PDU: Switched, Monitoring
EPTK     A  High Function 9xC19 PDU 3-Phase: Switched, Monitoring
           (option with new 7014)
EPTL     A  High Function 9xC19 PDU 3-Phase: Switched, Monitoring
EPTM     A  High Function 12xC13 PDU: Switched, Monitoring (option
           with new 7014)
EPTN     A  High Function 12xC13 PDU: Switched, Monitoring
EPTP     A  High Function 12xC13 PDU 3-Phase: Switched, Monitoring
           (option with new 7014)
EPTQ     A  High Function 12xC13 PDU 3-Phase: Switched, Monitoring
ER00     A  Custom Soln Center Services per PRPQ 8A2064
ER02     A  Rack Content Specify: 8408-E8D
ER03     A  Rack Content Specify: 2076-224 - 2U
ER04     A  Rack Content Specify: 2076-124 - 2U
ER07     A  Rack Content Specify: 1611-16E 1EIA (BINGO)
ER08     A  Rack Content Specify: 1455-24E/7120-24E
ER09     A  Rack Content Specify: 1455-48E
ER0A     A  Rack Content Specify: 1455-64C
ER0B     A  Rack Content Specify: 1455-48T
ER0C     A  Rack Content Specify: 1455-64F
ER0D     A  Rack Content Specify: 9109-RMD
ER0E     A  Rack Content Specify: 7316-TF4 -- 1 EIA
ER0H     S  Rack Content Specify: 8248-L4T
ER0J     S  Rack Content Specify: 8412-EAD
ER0M     A  Rack Content Specify for #EMX0 I/O Expansion Drawer
ER0T     A  Rack Content Specify 8286-41A/42A - 4EIA
ER0U     A  Rack Content Specify: 8284-22A - 2EIA
ER0V     A  Rack Content Specify: 8247/5148-22L - 2EIA
ER0Y     A  Rack Content Specify: 8412-EAD
ER0Z     A  Rack Content Specify: 8247-42L - 4EIA
ER10     A  Rack Content Specify first enclosure: 9119-MHE,
           9119-MME - 7 EIA
ER11     A  Rack Content Specify second enclosure: 9119-MHE,
           9119-MME - 12 EIA
ER12     A  Rack Content Specify third enclosure: 9119-MHE,
           9119-MME - 17 EIA
ER13     A  Rack Content Specify fourth enclosure: 9119-MHE,
           9119-MME - 22 EIA
ER14     A  Rack Content Specify 1U Horizontal PDU - 1 EIA
ER15     A  Rack Content Specify reserve 1U rack space for PDU
ER17     A  Rack Content Specify: 8408-E8E
ER18     A  Rack Content Specify: 5148/8247-21L - 2EIA
ER19     A  RACK SPECIFY FC EMX0
ER1B     A  Rack Content Specify: Reserve 1U Rack Space at Bottom of Rack
ER1D     A  Rack Content Specify: 8831-NF2
ER1F     A  FlashSystem 9840/9843 - 2 E1A
ER1H     A  Rack Content Specify: 8831-F36
ER1T     A  Rack Content Specify: Reserve 1U Rack Space at Top of Rack
ER1U     S  Rack content specify 5147-1F2 3EIA
ER1V     A  Rack Content Specify: 8831-S52 1EIA
ER24     A  Rack Content Specify: 8335-GCA 2EIA
ER25     S  Rack Content Specify: 8335-GTA 2EIA
ER26     A  Rack Content Specify: 8867-FM1/FM2 1EIA
ER28     A  Rack Content Specify 8335 - GTB 2EIA
ER29     A  Rack Content Specify 5147-084 5EIA
ER2B     A  Rack Content Specify: Reserve 2U Rack Space at Bottom
           of Rack
ER2T     A  Rack Content Specify: Reserve 2U Rack Space at Top of
           Rack
ERG0     A  Rack Rear Extension
ERG7     A  Front Door for Power 770 & 780 2.0 Meter Rack (High
           Perforation)
ERGB     A  Acoustic Black Front Door
ERGC     A  Ruggedized Rack Feature, Extra Strength
ERGD     A  Rack Doors for 2M Ruggedized Rack
ER1L     A  Rack Content Specify: 8408-44E
ER1P     S  Rack Content Specify: 8348-21C 2EIA
ER30     A  Rack Content Specify: 8284-21A - 2EIA
ERC0     A  Rack Content Specify EXP12SX #ESLL/#ELLL 2-EIA/2U
ERC1     A  Rack Content Specify EXP24SX #ESLS/#ELLS 2-EIA/2U
ERC2     A  Rack Content Specify 7063-CR1
ERLR     A  Left/Right PDU Redundancy
ESC0     A  S&H - No Charge
ESC1     A  Rack S&H-a
ESS0     A  ESS Seagate Solution Specify
ESS1     A  ESS GL2S Solution Specify (4TB HDD) - 664 TB Raw Disk
           Capacity
ESS2     A  ESS GL2S Solution Specify (8TB HDD) - 1328 TB Raw Disk
           Capacity
ESS3     A  ESS GL2S Solution Specify (10TB HDD) - 1660 TB Raw Disk
           Capacity
ESS4     A  ESS GL4S Solution Specify (4TB HDD) - 1336 TB Raw Disk
           Capacity
ESS5     A  ESS GL4S Solution Specify (8TB HDD) - 2672 TB Raw Disk
           Capacity
ESS6     A  ESS GL4S Solution Specify (10TB HDD) - 3340 TB Raw Disk
           Capacity
ESS7     A  ESS GL6S Solution Specify (4TB HDD) - 2008 TB Raw Disk
           Capacity
ESS8     A  ESS GL6S Solution Specify (8TB HDD) - 4016 TB Raw Disk
           Capacity
ESS9     A  ESS GL6S Solution Specify (10TB HDD) - 5020 TB Raw Disk
           Capacity
ESSC     A  ESS 2U24 STORAGE SOLUTION SPECIFY
ESSD     A  ESS GS1S Solution Specify (3.84TB SSD) - 92 TB Raw Disk
           Capacity
ESSE     A  ESS GS1S SOLUTION SPECIFY (15.36TB SSD) - 368 TB Raw Disk
           Capacity
ESSF     A  ESS GS2S SOLUTION SPECIFY (3.84TB SSD) - 184 TB Raw Disk
           Capacity
ESSG     A  ESS GS2S SOLUTION SPECIFY (15.36TB SSD) - 737 TB Raw Disk
           Capacity
ESSK     A  ESS GS4S SOLUTION SPECIFY (3.84TB SSD) - 368 TB Raw Disk
           Capacity
ESSL     A  ESS GS4S SOLUTION SPECIFY (15.36TB SSD) - 1474 TB Raw Disk
           Capacity

Feature descriptions

The following is a list of all feature codes in numeric order.

Attributes, as defined in the following feature descriptions, state the interaction of requirements among features.

Minimums and maximums are the absolute limits for a single feature without regard to interaction with other features. The maximum valid quantity for MES orders may be different than for initial orders. The maximums listed below refer to the largest quantity of these two possibilities.

The order type defines if a feature is orderable only on initial orders, only on MES orders, on both initial and MES orders, or if a feature is supported on a model due to a model conversion. Supported features cannot be ordered on the converted model, only left on or removed from the converted model.

(#0010) - One CSC Billing Unit

One CSC Billing Unit

  • Attributes provided:

    One CSC Billing Unit

  • Attributes required: None
  • For 7014-T42: (#0010)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 9999)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#0011) - Ten USC Billing Units

Ten CSC Billing Units

  • Attributes provided:

    Ten USC Billing Units

  • Attributes required: None
  • For 7014-T42: (#0011)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 9999)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#0050) IBM Express Seller Indicator

This feature is a no-charge feature used for administrative purposes by IBM and IBM Business Partners.

  • Attributes provided: None
  • Attributes required: None
  • For 7014-T42: (#0050)
    • Maximum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#0127) Rack Content Specify: 7026/H70 - 8EIA
  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 8 EIA rack space
  • For 7014-T42: (#0127)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#0128) Rack Content Specify: 7026/H80 - 5EIA

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 5 EIA rack space
  • For 7014-T42: (#0128)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#0129) Rack Content Specify: 7026/M80 - 8EIA

(No Longer Available as of June 23, 2006)

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 8 EIA rack space
  • For 7014-T42: (#0129)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#0147) Rack Content Specify: 3590/B11 - (2 x B11 = 12EIA)

Indicator of rack space utilization for 3590/B11, Disk Drawer.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 12 EIA rack space for two 3590/B11's
  • For 7014-T42: (#0147)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#0149) Rack Content Specify: UPS/MOD - 4EIA

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 4 EIA rack space
  • For 7014-T42: (#0149)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#0156) Rack Content Specify: 7133/D40 - 4EIA

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 4 EIA units of rack space
  • For 7014-T42: (#0156)
    • Minimum required: 0
    • Maximum allowed: No max (Initial Order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#0162) Rack Content Specify: 7337/306 - 5EIA

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 5 EIA rack space
  • For 7014-T42: (#0162)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#0165) Rack Content Specify: 2104/DL1 - 3EIA

(No Longer Available as of June 28, 2002)

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 3EIA rack space for 2104/DL1
  • For 7014-T42: (#0165)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#0169) Rack Content Specify: 3490/F11 - 4EIA

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 4 EIA rack space
  • For 7014-T42: (#0169)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#0170) Rack Content Specify: 3570/C11 - 6EIA

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 6 EIA units of rack space
  • For 7014-T42: (#0170)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#0171) Rack Content Specify: 3590/E11 - (1X OR 2X = 12EIA)

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 12 EIA units of rack space
  • For 7014-T42: (#0171)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#0172) Rack Content Specify: 3570/C12 - 6EIA

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 6 EIA units of rack space
  • For 7014-T42: (#0172)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#0173) Rack Content Specify: Secondary I/O Drawer, AC Power - 5EIA

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 5 EIA rack space
  • For 7014-T42: (#0173)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#0175) Rack Content Specify: 3 EIA

(No Longer Available as of September 13, 2002)

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 3 EIA rack space.
  • For 7014-T42: (#0175)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#0176) Rack Content Specify: Primary I/O Drawer, - 5EIA

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 5 EIA rack space
  • For 7014-T42: (#0176)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#0178) Rack Content Specify: 7026/B80 -- 5 EIA
  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 5 EIA rack space
  • For 7014-T42: (#0178)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#0179) Rack Content Specify: 2104/DU3 - 3EIA
  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 3 EIA rack space
  • For 7014-T42: (#0179)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#0180) Rack Content Specify: 2108/G07 - 2EIA
  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 2 EIA rack space
  • For 7014-T42: (#0180)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#0181) Rack Content Specify: 2109/S08 - 1EIA
  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 1 EIA rack space
  • For 7014-T42: (#0181)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#0182) Rack Content Specify: 2109/S16 - 2EIA
  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 2 EIA rack space
  • For 7014-T42: (#0182)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#0183) Rack Content Specify: 9910/A30 - 5EIA
  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 5 EIA rack space
  • For 7014-T42: (#0183)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#0184) Rack Content Specify: 9910/A31 - 5EIA
  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 5 EIA rack space
  • For 7014-T42: (#0184)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#0185) Rack Content Specify: 9910/P60 - 6EIA
  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 6 EIA rack space
  • For 7014-T42: (#0185)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#0186) Rack Content Specify: 9910/P61 - 6EIA
  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 6 EIA rack space
  • For 7014-T42: (#0186)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#0187) Rack Content Specify: FC 6606 -- 3 EIA (9910 UPS Battery Module)
  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 3 EIA rack space.
  • For 7014-T42: (#0187)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#0188) Rack Content Specify: 7026/6H1 - 5EIA

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 5U (EIA) of rack space
  • For 7014-T42: (#0188)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#0189) Rack Content Specify: 7026/6M1 - 8EIA (CEC Drawer)

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 8U (EIA) of rack space
  • For 7014-T42: (#0189)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#0194) Rack Content Specify: 3590/A60 - 9U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 9U of rack space
  • For 7014-T42: (#0194)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#0195) Rack Content Specify: 7038/6M2 - 8U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 8U of rack space
  • For 7014-T42: (#0195)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0196) Rack Content Specify: 7311/D10 - (2 x D10 = 4U)

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 4U of rack space
  • For 7014-T42: (#0196)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0197) Rack Content Specify: 7028-6C1 -- 5 EIA

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 5 EIA of rack space
  • For 7014-T42: (#0197)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#0198) Rack Content Specify: 9910/P33 - 2U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 2U of rack space
  • For 7014-T42: (#0198)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#0199) Rack Content Specify: FC #6607 on 9910-P33 - 2U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization
  • Attributes required: Feature # 0198 and 2U rack space
  • For 7014-T42: (#0199)
    • Minimum required: 0
    • Maximum allowed: 4 (Initial order maximum: 4)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial

Note: Maximum of four per feature #0198.

(#0200) Rack Content Specify: 9910/B38 - 4U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 4U rack space
  • For 7014-T42: (#0200)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#0201) Rack Content Specify: FC #6621 on 9910-B38 - 2U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization
  • Attributes required: Feature #0200 and 2U rack space
  • For 7014-T42: (#0201)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 8)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#0202) Rack Content Specify: 7315/CR2 - 1U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 1U of rack space
  • For 7014-T42: (#0202)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0203) Rack Content Specify: 7026/6H0 - 5U (EIA)

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 5U of rack space
  • For 7014-T42: (#0203)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#0204) Rack Content Specify: 2104/DS4 - 3EIA
  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 3 EIA rack space
  • For 7014-T42: (#0204)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0205) Rack Content Specify: 3592/J1A/E05 - 10EIA
  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 10 EIA rack space
  • For 7014-T42: (#0205)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply

Note: Each model 3592-J1A or E05 occupies half of the rack width for the full 10 EIA height. Two of these models can share the same 10 EIA rack space.

(#0206) Rack Content Specify: 7028/6C4 - 4U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 4U of rack space
  • For 7014-T42: (#0206)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0207) Rack Content Specify: 7029/6C3 - 4U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 4U of rack space
  • For 7014-T42: (#0207)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0208) Rack Content Specify: 2109/F16 - 1EIA
  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 1 EIA rack space
  • For 7014-T42: (#0208)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0210) Rack Content Specify: 7311/D20 - 4U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 4U of rack space
  • For 7014-T42: (#0210)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0213) Rack Content Specify: 3542/2RU - 3EIA (FAST T200)
  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 3 EIA rack space
  • For 7014-T42: (#0213)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0214) Rack Content Specify: 3552/1RU - 4EIA (FAST T500)
  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 4 EIA rack space
  • For 7014-T42: (#0214)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0215) Rack Content Specify: 3560/1RU - 3EIA (FAST EXP500)
  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 3 EIA rack space
  • For 7014-T42: (#0215)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0216) Rack Content Specify : 7316/TF2 - 1 EIA:
  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 1 EIA rack space.
  • For 7014-T42: (#0216)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0217) Rack Content Specify: 3542/2RX - 3EIA (FAST T200 EMEA)
  • Attributes provided:
  • Attributes required:
  • For 7014-T42: (#0217)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum, No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0218) Rack Content Specify: 9910/P18 - 2U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 2U of rack space
  • For 7014-T42: (#0218)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0219) Rack Content Specify: FC #6606 on 9910-P18 - 2U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 2U of rack space
  • For 7014-T42: (#0219)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0220) Rack Content Specify: 1742/1RU - 4EIA
  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 4 EIA rack space
  • For 7014-T42: (#0220)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0221) Rack Content Specify: 1740/1RU - 3EIA
  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 3 EIA rack space
  • For 7014-T42: (#0221)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0222) Rack Content Specify: 1742/90U - 4EIA
  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 4 EIA rack space
  • For 7014-T42: (#0222)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0223) Rack Content Specify: 3590/H11 - 12EIA
  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 12 EIA rack space
  • For 7014-T42: (#0223)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0224) Rack Content Specify: 9910/M15 - 1U
  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 1U (EIA) of rack space
  • For 7014-T42: (#0224)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0225) Rack Content Specify: 9910/M30 - 2U
  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 2U (EIA) of rack space
  • For 7014-T42: (#0225)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0226) Rack Content Specify: FC #3401 on 9910/M30 - 2U (9910 UPS Battery Module)
  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 2U of rack space
  • For 7014-T42: (#0226)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0227) Rack Content Specify: 3592/J70 - 7EIA
  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 7 EIA rack space
  • For 7014-T42: (#0227)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0228) Rack Content Specify: 7311/D11 - (2 x D11 = 4U)

Indicator of rack space utilization.

  • Attributes provided: None
  • Attributes required: None
  • For 7014-T42: (#0228)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0229) Rack Content Specify: 9111/520 - 4U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 4U of rack space
  • For 7014-T42: (#0229)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0230) Rack Content Specify: 9113/550 - 4U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 4U of rack space
  • For 7014-T42: (#0230)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0231) Rack Content Specify: 9117/570/MMA/MMB, 8234-EMA - 4U

(No Longer Available as of November 30, 2015)

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 4U of rack space
  • For 7014-T42: (#0231)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0232) Rack Content Specify: 9117/570/MMA/MMB, 8234-EMA - 8U

(No Longer Available as of November 30, 2015)

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 8U of rack space
  • For 7014-T42: (#0232)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0233) Rack Content Specify: 7316-TF3 -- 1 EIA

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 1U (EIA) of rack space
  • For 7014-T42: (#0233)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0234) Rack Content Specify: 1710/10U, 1812/81A, 1818/D1A - 3EIA
(DASD EXP)(AC, 2 Cords)
  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 3 EIA rack space
  • For 7014-T42: (#0234)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0235) Rack Content Specify: 1722/60U - 3EIA
  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 3 EIA rack space
  • For 7014-T42: (#0235)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0236) Rack Content Specify: 9910/P65 - 3EIA
  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 3 EIA rack space
  • For 7014-T42: (#0236)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0241) Rack Content Specify: 9117/570/MMA/MMB - 12U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 12U of rack space
  • For 7014-T42: (#0241)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0242) Rack Content Specify: 9117/570/MMA/MMB - 16U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 16U of rack space
  • For 7014-T42: (#0242)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0243) Rack Content Specify: 9910/P30 - 2EIA
  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 2 EIA rack space
  • For 7014-T42: (#0243)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0244) Rack Content Specify: 9910/P30 Battery Module - 2EIA
  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 2 EIA rack space
  • For 7014-T42: (#0244)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0245) Rack Content Specify: 9910/P64 - 5EIA
  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 5 EIA rack space
  • For 7014-T42: (#0245)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0246) Rack Content Specify: 9910 Feature Number 6641 (9910-P64, P65 Battery Module) - 3EIA
  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 3 EIA rack space
  • For 7014-T42: (#0246)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0247) Rack Content Specify: 7310/CR2 - 1U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 1U of rack space
  • For 7014-T42: (#0247)
    • Minimum required: 0
    • Maximum allowed: no max (Initial order maximum: no max )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0249) Rack Content Specify: 7031-D24-4U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 4U of rack space
  • For 7014-T42: (#0249)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Yes
    • Return parts MES: No
(#0250) Rack Content Specify: 9124/720 - 4U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 4U of rack space
  • For 7014-T42: (#0250)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0251) Rack Content Specify: 9123/710 - 2EIA
  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 2 EIA of rack space
  • For 7014-T42: (#0251)
    • Minimum required: 0
    • Maximum allowed: 0 (Initial order maximum: 0 )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0252) Rack Content Specify: 7315/CR3 1U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 1U of rack space
  • For 7014-T42: (#0252)
    • Minimum required: 0
    • Maximum allowed: no max (Initial order maximum: no max )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0253) Rack Content Specify: 7310/CR3 1U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 1U of rack space
  • For 7014-T42: (#0253)
    • Minimum required: 0
    • Maximum allowed: no max (Initial order maximum: no max )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0254) Rack Content Specify: 1724-100 or 1814-70A/72A -- 3EIA

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 3 EIA rack space
  • For 7014-T42: (#0254)
    • Minimum required: 0
    • Maximum allowed: 14 (Initial order maximum: 14)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#0255) Rack Content Specify: 9110/510 - 2EIA
  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 2 EIA of rack space
  • For 7014-T42: (#0255)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0256) Rack Content Specify: 7314-G30 -4 EIA

Indicator of rack space utilization.

  • Attributes provided: 4 EIA units of rack space
  • Attributes required: None
  • For 7014-T42: (#0256)
    • Minimum required: 0
    • Maximum allowed: 10 (Initial order maximum: 10)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#0257) Rack Content Specify: 9131-52A - 4U

Indicator of rack space utilization.

  • Attributes provided: indicator of rack space utilization
  • Attributes required: 4U of rack space
  • For 7014-T42: (#0257)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0258) Rack Content Specify: 9133-55A - 4U

Indicator of rack space utilization.

  • Attributes provided: indicator of rack space utilization
  • Attributes required: 4U of rack space
  • For 7014-T42: (#0258)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0259) Rack Content Specify: 9115/505 - 1U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 1U of rack space
  • For 7014-T42: (#0259)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0260) Rack Content Specify: 9116/561 - 4U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 4U of rack space
  • For 7014-T42: (#0260)
    • Minimum required: 0
    • Maximum allowed: no max (Initial order maximum: no max )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0261) Rack Content Specify: 9116/561 - 8U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 8U of rack space
  • For 7014-T42: (#0261)
    • Minimum required: 0
    • Maximum allowed: no max (Initial order maximum: no max )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0262) Rack Content Specify: 7310/CR4 1U

(No Longer Available as of November 27, 2009)

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 1U of rack space
  • For 7014-T42: (#0262)
    • Minimum required: 0
    • Maximum allowed: no max (Initial order maximum: no max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#0263) Rack Content Specify FC 5886 - 2EIA

Indicator of rack space utilization.

  • Attributes provided: Rack space utilization
  • Attributes required: 2 EIA units of rack space
  • For 7014-T42: (#0263)
    • Minimum required: 0
    • Maximum allowed: 20 (Initial order maximum: 20)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#0269) Rack Content Specify 7048-120 - 1 EIA

(No Longer Available as of June 23, 2006)

Indicator of rack space utilization for 7048-120

  • Attributes provided: rack space utilization
  • Attributes required: 1unit of rack space
  • For 7014-T42: (#0269)
    • Minimum required: 0
    • Maximum allowed: 39 (Initial order maximum: 39 )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0270) Rack Content Specify 7048-270 - 6 EIA

(No Longer Available as of June 23, 2006)

Indicator of rack space utilization for 7048-270.

  • Attributes provided: rack space utilization
  • Attributes required: 6 units of rack space
  • For 7014-T42: (#0270)
    • Minimum required: 0
    • Maximum allowed: 7 (Initial order maximum: 7 )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0274) Rack Content Specify: 7214-1U2 - 1 EIA unit

Indicator of rack space utilization.

  • Attributes provided: Rack space utilization
  • Attributes required: 1 EIA unit
  • For 7014-T42: (#0274)
    • Minimum required: 0
    • Maximum allowed: 42 (Initial order maximum: 42)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#0275) - Rack Content Specify 1815-80A, 1818/51A/53A/80E 4U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 4 EIA of rack space
  • For 7014-T42: (#0275)
    • Minimum required: 0
    • Maximum allowed: 10 (Initial order maximum: 10)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#0278) Rack Content Specify: 8203-E4A - 4U

Indicator of rack space utilization

  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 4U of rack space
  • For 7014-T42: (#0278)
    • Minimum required: 0
    • Maximum allowed: 10 (Initial order maximum: 10)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#0284) Rack Content Specify 7042-CR4 1U

(No Longer Available as of December 31, 2009)

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 1U of rack space
  • For 7014-T42: (#0284)
    • Minimum required: 0
    • Maximum allowed: 40 (Initial order maximum: 40)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#0286) - Rack Content Specify for 7042/CR5
  • For 7014-T42: (#0286)
    • Minimum required: 0
    • Maximum allowed: 42 (Initial order maximum: 42)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#0288) Rack Content Specify: 8204-E8A - 4U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization
  • For 7014-T42: (#0288)
    • Minimum required: 0
    • Maximum allowed: 10 (Initial order maximum: 10)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#0297) - Rack Content Specify: 8233-E8B - 4U
  • For 7014-T42: (#0297)
    • Minimum required: 0
    • Maximum allowed: 10 (Initial order maximum: 10)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#0298) - Rack Content Specify: 8202-E4B - 4U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: None
  • For 7014-T42: (#0298)
    • Minimum required: 0
    • Maximum allowed: 10 (Initial order maximum: 10)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES:
(#0299) - Rack Content Specify: 8205-E6B -- 4U

(No Longer Available as of November 30, 2015)

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: None
  • For 7014-T42: (#0299)
    • Minimum required: 0
    • Maximum allowed: 10 (Initial order maximum: 10)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES:
(#0303) - RACK SPECIFY FC 5802

Allocate 4EA space in the rack for #5802.

  • Attributes provided: Specify 4 EIA Space
  • Attributes required: Available 4EIA space in 7014-B42, S25,TOO or T42.
  • For 7014-T42: (#0303)
    • Minimum required: 0
    • Maximum allowed: 10 (Initial order maximum: 10)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#0315) Rack Content Specify: 7036-P16 - 1U

Indicator of rack space utilization

  • Attributes provided: Indicator of rack space utilization
  • Attributes required: None
  • For 7014-T42: (#0315)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 8)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0316) Rack Content Specify: 9110-51A - 2U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 2U of rack space
  • For 7014-T42: (#0316)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0317) Rack Content Specify: 7037-A50 - 5U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 5U of rack space
  • For 7014-T42: (#0317)
    • Minimum required:
    • Maximum allowed: (Initial order maximum: )
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES:
(#0320) Rack Content Specify: 9910-E82/E83- 6 EIA

(No Longer Available as of September 10, 2013)

Indicator of rack space utilization.

  • Attributes provided: Reserves rack space
  • Attributes required: 6 EIA units of rack space
  • For 7014-T42: (#0320)
    • Minimum required: 0
    • Maximum allowed: no max (Initial order maximum: no max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#0321) Rack Content Specify: 9910-E82/E83 FC 6646/6646 Battery Module 3 EIA

(No Longer Available as of September 10, 2013)

Indicator of rack space utilization.

  • Attributes provided: reserves rack space
  • Attributes required: 3 EIA units of rack space
  • For 7014-T42: (#0321)
    • Minimum required: 0
    • Maximum allowed: no max (Initial order maximum: no max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#0322) Rack Content Specify: 3580/H3L/H3S - 2U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 2U of rack space
  • For 7014-T42: (#0322)
    • Minimum required: 0
    • Maximum allowed: 21 (Initial order maximum: 21)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES:
(#0323) - Rack Content Specify: 5887-2U

Indicator of rack space utilization

  • Attributes provided: Indicator of rack space utilization
  • Attributes required: None
  • For 7014-T42: (#0323)
    • Minimum required: 0
    • Maximum allowed: 21 (Initial order maximum: 21)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES:
(#0324) - Rack Content Specify: 7042-CR6/CR7/CR8/CR9 - 1EIA

Rack Content Specify Code for 7042-CR6/CR7/CR8/CR9 to indicate 1EIA rack space utilization.

  • Attributes provided: Rack space utilization
  • Attributes required: None
  • For 7014-T42: (#0324)
    • Minimum required: 0
    • Maximum allowed: 42 (Initial order maximum: 42)
    • OS level required: n/a
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: No
(#0326) Rack Content Specify: 3580/L33/L43/S43 - 3U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 3U of rack space
  • For 7014-T42: (#0326)
    • Minimum required: 0
    • Maximum allowed: 14 (Initial order maximum: 14)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES:
(#0327) Rack Content Specify: 3573/L2U - 2U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 2U of rack space
  • For 7014-T42: (#0327)
    • Minimum required: 0
    • Maximum allowed: 21 (Initial order maximum: 21)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES:
(#0328) Rack Content Specify: 3573/L4U - 4U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 4U of rack space
  • For 7014-T42: (#0328)
    • Minimum required: 0
    • Maximum allowed: 10 (Initial order maximum: 10)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES:
(#0331) Rack Content Specify: 7874-024 - 1U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 1U of rack space.
  • For 7014-T42: (#0331)
    • Minimum required: 0
    • Maximum allowed: 39 (Initial order maximum: 39)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#0332) Rack Content Specify: 7874-040 - 4U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 4U of rack space.
  • For 7014-T42: (#0332)
    • Minimum required: 0
    • Maximum allowed: 10 (Initial order maximum: 10)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#0334) Rack Content Specify: 7874-120 - 7U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 7U of rack space.
  • For 7014-T42: (#0334)
    • Minimum required: 0
    • Maximum allowed: 6 (Initial order maximum: 6)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#0335) Rack Content Specify: 7874-240 - 14U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 14U of rack space.
  • For 7014-T42: (#0335)
    • Minimum required: 0
    • Maximum allowed: 3 (Initial order maximum: 3)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#0336) Rack Content Specify 3572/SH3/SH4 - 1EIA

Rack Content Specify 3572/SH3/SH4 - 1EIA

  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 1U of rack space
  • For 7014-T42: (#0336)
    • Minimum required: 0
    • Maximum allowed: 42 (Initial order maximum: 42)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#0337) - Rack Content Specify: 9910-E50 - 3U

(No Longer Available as of September 10, 2013)

Indicator of rack space utilization

  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 3U of rack space
  • For 7014-T42: (#0337)
    • Minimum required: 0
    • Maximum allowed: 14 (Initial order maximum: 14)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#0338) Rack Content Specify: 9910-E50 with Feature 6648

(No Longer Available as of September 10, 2013)

Indicator of rack space utilization

  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 3U of rack space
  • For 7014-T42: (#0338)
    • Minimum required: 0
    • Maximum allowed: 14 (Initial order maximum: 14)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#0339) Rack Content Specify, 1818-RS2, 1818-RS3
  • For 7014-T42: (#0339)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: No
(#0340) Rack Content Specify: 2498-B40/B24/F48 SAN Switch
  • For 7014-T42: (#0340)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: No
(#0343) Rack Content Specify: 3576/L5B - 5U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 5U of rack space
  • For 7014-T42: (#0343)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 8)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES:
(#0345) Rack Content Specify: 3576/E9U - 9U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 9U of rack space
  • For 7014-T42: (#0345)
    • Minimum required: 0
    • Maximum allowed: 4 (Initial order maximum: 4)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES:
(#0346) Rack Content Specify: 3577/L5U -5U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 5U of rack space
  • For 7014-T42: (#0346)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 8)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES:
(#0361) Rack Content Specify 5 EIA for FC 0595

Rack Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 5 EIA rack space
  • For 7014-T42: (#0361)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 8)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#0363) - 2EIA Rack Content Specify

Allocate one 2EIA (2U) space in the rack for one IBM 2076 Storwize V7000 Control Enclosure. (2076-112/124/212/224/312 /324)

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 2U of rack space.
  • For 7014-T42: (#0363)
    • Minimum required: 0
    • Maximum allowed: No Maximum (Initial order maximum: 9999)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#0364) Rack Content Specify, Juniper EX4200 Switch
  • For 7014-T42: (#0364)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: No
(#0370) - Rack Content Specify: 8231-E2B -- 2U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: None
  • For 7014-T42: (#0370)
    • Minimum required: 0
    • Maximum allowed: 21 (Initial order maximum: 21)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES:
(#0379) - Rack Content Specify: 7874-036 - 1U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 1U of rack space.
  • For 7014-T42: (#0379)
    • Minimum required: 0
    • Maximum allowed: 39 (Initial order maximum: 39)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#0380) - Rack Content Specify: 7874-072 - 5U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 5U of rack space.
  • For 7014-T42: (#0380)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 8)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#0381) - Rack Content Specify: 7874-324 - 14U

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 14U of rack space.
  • For 7014-T42: (#0381)
    • Minimum required: 0
    • Maximum allowed: 3 (Initial order maximum: 3)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#0384) - Rack Content Specify: 9179-MHB, 4U.

Rack Content Specify Code for a single enclosure (4U) 9179-MHB to indicate rack space utilization.

  • For 7014-T42: (#0384)
    • Minimum required: 0
    • Maximum allowed: 10 (Initial order maximum: 10)
    • OS level required: n/a
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#0385) - Rack Content Specify: 9179-MHB, 8U.

Rack Content Specify Code for a two enclosure (8U) 9179-MHB to indicate rack space utilization.

  • For 7014-T42: (#0385)
    • Minimum required: 0
    • Maximum allowed: 5 (Initial order maximum: 5)
    • OS level required: n/a
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#0386) - Rack Content Specify: 9179-MHB, 12U.

Rack Content Specify Code for a three enclosure (12U) 9179-MHB to indicate rack space utilization.

  • For 7014-T42: (#0386)
    • Minimum required: 0
    • Maximum allowed: 3 (Initial order maximum: 3)
    • OS level required: n/a
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#0387) - Rack Content Specify: 9179-MHB, 16U.

Rack Content Specify Code for a four enclosure (16U) 9179-MHB to indicate rack space utilization.

  • For 7014-T42: (#0387)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required: n/a
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#0388) - Rack Content Specify, Juniper EX4500 Switch
  • For 7014-T42: (#0388)
    • Minimum required: 0
    • Maximum allowed: (Initial order maximum: )
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES:
(#0389) - Rack Content Specify, Switch Network Documentation Drawer
  • For 7014-T42: (#0389)
    • Minimum required: 0
    • Maximum allowed: (Initial order maximum: )
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES:
(#0390) - Rack Content Specify, DS3500 Storage Drawer
  • For 7014-T42: (#0390)
    • Minimum required: 0
    • Maximum allowed: (Initial order maximum: )
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES:
(#0392) - Rack Content Specify: 8246-Lxx
  • For 7014-T42: (#0390)
    • Minimum required: 0
    • Maximum allowed: 21 (Initial order maximum: 21)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#0458) - Rack Content Specify: 5888-1U

Indicator of rack space utilization

  • Attributes provided: Indicator of rack space utilization
  • Attributes required: None
  • For 7014-T42: (#0458)
    • Minimum required: 0
    • Maximum allowed: 42 (Initial order maximum: 42)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#0469) Customer Specified Rack Placement

Provides the customer the ability to specify the physical location of the system drawers and attached expansion drawers in the rack. The customer's input is collected and verified via the marketing configurator. The Clients request will be reviewed for safe handling by checking weight distribution within the rack. Final approval for the requested drawer placement location will be provided by the Manufacturing Plant. This information is then used by IBM Manufacturing to assemble the system components (drawers) in the rack accordinating to the Clients request.

The CFReport from the marketing configurator must be submitted to:

www.ibm.com/servers/eserver/power/csp

(US Business Partners and Distributors can bypass this step.)

If #0469 is not on the initial rack order, component placement within the rack will be determined by IBM.

  • Attributes provided: Location of the system components (drawers) within a rack according to the Clients documented request.
  • Attributes required: System components and Rack on the same initial order.
  • For 7014-T42: (#0469)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1 )
    • OS level required: none
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#0703) Solution Indicator

(No Longer Available as of December 31, 2002)

This feature is required when ordering certain Infrastructure offerings. It is for administrative use only and provides no parts.

  • Attributes provided: None
  • Attributes required: None
  • For 7014-T42: (#0703)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: AIX 4.3.3 or AIX 5.1, or later
    • Initial Order/MES/Both/Supported: Initial
(#0704) HA Solution Indicator

(No Longer Available as of December 31, 2002)

This feature is required when ordering certain High Availability Infrastructure offerings. It is for administrative use only and provides no parts.

  • Attributes provided: None
  • Attributes required: None
  • For 7014-T42: (#0704)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: AIX 4.3.3 or AIX 5.1, or later
    • Initial Order/MES/Both/Supported: Initial
(#0710) Balanced Warehouse Solution:

This feature specifies that the DS4000 EXP810 ordered will be a component of the Balanced Warehouse Solution. This feature will automatically be selected by the configurator when a Balanced Warehouse solution is configured. The solution will be integrated at the Customer Solution Center.

  • Attributes provided: None
  • Attributes required: None
  • For 7014-T42: (#0710)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#0711) - IBM mCommerce Application Solution Indicator

(No Longer Available as of December 31, 2012)

This feature specifies a 8233-E8B server, 7042-CR6 (HMC), 7014-T42 (rack), and 7318-TF3 (console) configuration for the IBM mCommerce Application Solution. The solution will be integrated at the Customer Solution Center.

  • Attributes provided: None
  • Attributes required: None
  • For 7014-T42: (#0711)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Yes
    • Return parts MES:
(#0712) - MANUFACTURING ROUTING CODE FOR CSC

A manufacturing routing code used to route orders to the Custom Solution Center for assembly

  • Attributes provided: Manufacturing Routing Code
  • Attributes required: None
  • For 7014-T42: (#0712)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#1114) Smart Analytics System routing indicator

(No Longer Available as of January 24, 2017)

  • For 7014-T42: (#1114)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: No
(#1140) - Custom Service Specify, Rochester Minn, USA

Having #1140 on the order, will cause the order to be routed to Rochester and the machine to be internally routed to the CSC build area in building 114 (Rochester).

  • Attributes provided: Customization
  • Attributes required: None
  • For 7014-T42: (#1140)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#4651) Rack Indicator, Rack #1

When added to an initial rack order, this indicator is used to specify the first rack for a multi-rack order, or the only rack for a single rack order. When added to an initial rack-mountable device order this indicator is used to specify that the rack-mountable device (such as a system or I/O drawer) is to be mounted in rack #1 of a multi-rack order.

Note: For 19" rack-mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed.

For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 7014-T42: (#4651)
    • Minimum required: 0
    • Maximum allowed : No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#4652) Rack Indicator, Rack #2

When added to an initial rack order, this indicator is used to specify the second rack for a multi-rack order. When added to an initial rack- mountable device order, this indicator is used to specify that the rack- mountable device (such as a system or I/O drawer) is to be mounted in rack #2 of a multi-rack order.

Note: For 19" rack-mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed.

For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 7014-T42: (#4652)
    • Minimum required: 0
    • Maximum allowed : No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#4653) Rack Indicator, Rack #3

When added to an initial rack order, this indicator is used to specify the third rack for a multi-rack order. When added to an initial rack- mountable device order, this indicator is used to specify that the rack- mountable device (such as a system or I/O drawer) is to be mounted in rack #3 of a multi-rack order.

Note: For 19" rack-mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed.

For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 7014-T42: (#4653)
    • Minimum required: 0
    • Maximum allowed : No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#4654) Rack Indicator, Rack #4

When added to an initial rack order, this indicator is used to specify the fourth rack for a multi-rack order. When added to an initial rack- mountable device order, this indicator is used to specify that the rack- mountable device (such as a system or I/O drawer) is to be mounted in rack #4 of a multi-rack order.

Note: For 19" rack-mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed.

For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 7014-T42: (#4654)
    • Minimum required: 0
    • Maximum allowed : No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#4655) Rack Indicator, Rack #5

When added to an initial rack order, this indicator is used to specify the fifth rack for a multi-rack order. When added to an initial rack- mountable device order, this indicator is used to specify that the rack- mountable device (such as a system or I/O drawer) is to be mounted in rack #5 of a multi-rack order.

Note: For 19" rack-mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed.

For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 7014-T42: (#4655)
    • Minimum required: 0
    • Maximum allowed : No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#4656) Rack Indicator, Rack #6

When added to an initial rack order, this indicator is used to specify the sixth rack for a multi-rack order. When added to an initial rack- mountable device order, this indicator is used to specify that the rack- mountable device (such as a system or I/O drawer) is to be mounted in rack #6 of a multi-rack order.

Note: For 19" rack-mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed.

For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 7014-T42: (#4656)
    • Minimum required: 0
    • Maximum allowed : No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#4657) Rack Indicator, Rack #7

When added to an initial rack order, this indicator is used to specify the seventh rack for a multi-rack order. When added to an initial rack- mountable device order, this indicator is used to specify that the rack- mountable device (such as a system or I/O drawer) is to be mounted in rack #7 of a multi-rack order.

Note: For 19" rack-mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed.

For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 7014-T42: (#4657)
    • Minimum required: 0
    • Maximum allowed : No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#4658) Rack Indicator, Rack #8

When added to an initial rack order, this indicator is used to specify the eighth rack for a multi-rack order. When added to an initial rack- mountable device order, this indicator is used to specify that the rack- mountable device (such as a system or I/O drawer) is to be mounted in rack #8 of a multi-rack order.

Note: For 19" rack-mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed.

For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 7014-T42: (#4658)
    • Minimum required: 0
    • Maximum allowed : No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#4659) Rack Indicator, Rack #9

When added to an initial rack order, this indicator is used to specify the ninth rack for a multi-rack order. When added to an initial rack- mountable device order, this indicator is used to specify that the rack- mountable device (such as a system or I/O drawer) is to be mounted in rack #9 of a multi-rack order.

Note: For 19" rack-mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed.

For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 7014-T42: (#4659)
    • Minimum required: 0
    • Maximum allowed : No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#4660) Rack Indicator, Rack #10

When added to an initial rack order, this indicator is used to specify the tenth rack for a multi-rack order. When added to an initial rack- mountable device order, this indicator is used to specify that the rack- mountable device (such as a system or I/O drawer) is to be mounted in rack #10 of a multi-rack order.

Note: For 19" rack-mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed.

For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 7014-T42: (#4660)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#4661) Rack Indicator, Rack #11

When added to an initial rack order, this indicator is used to specify the eleventh rack for a multi-rack order. When added to an initial rack- mountable device order, this indicator is used to specify that the rack- mountable device (such as a system or I/O drawer) is to be mounted in rack #11 of a multi-rack order.

Note: For 19" rack-mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed.

For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 7014-T42: (#4661)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#4662) Rack Indicator, Rack #12

When added to an initial rack order, this indicator is used to specify the twelfth rack for a multi-rack order. When added to an initial rack- mountable device order, this indicator is used to specify that the rack- mountable device (such as a system or I/O drawer) is to be mounted in rack #12 of a multi-rack order.

Note: For 19" rack-mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed.

For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 7014-T42: (#4662)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#4663) Rack Indicator, Rack #13

When added to an initial rack order, this indicator is used to specify the thirteenth rack for a multi-rack order. When added to an initial rack-mountable device order, this indicator is used to specify that the rack-mountable device (such as a system or I/O drawer) is to be mounted in rack #13 of a multi-rack order.

Note: For 19" rack-mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed.

For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 7014-T42: (#4663)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#4664) Rack Indicator, Rack #14

When added to an initial rack order, this indicator is used to specify the fourteenth rack for a multi-rack order. When added to an initial rack-mountable device order, this indicator is used to specify that the rack-mountable device (such as a system or I/O drawer) is to be mounted in rack #14 of a multi-rack order.

Note: For 19" rack-mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed.

For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 7014-T42: (#4664)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#4665) Rack Indicator, Rack #15

When added to an initial rack order, this indicator is used to specify the fifteenth rack for a multi-rack order. When added to an initial rack-mountable device order, this indicator is used to specify that the rack-mountable device (such as a system or I/O drawer) is to be mounted in rack #15 of a multi-rack order.

Note: For 19" rack-mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed.

For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 7014-T42: (#4665)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#4666) Rack Indicator, Rack #16

When added to an initial rack order, this indicator is used to specify the sixteenth rack for a multi-rack order. When added to an initial rack-mountable device order, this indicator is used to specify that the rack-mountable device (such as a system or I/O drawer) is to be mounted in rack #16 of a multi-rack order.

Note: For 19" rack-mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed.

For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 7014-T42: (#4666)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#4690) Rack Status Beacon

(No Longer Available as of November 18, 2005)

The Rack Status Beacon is designed to be placed on the top of a rack and cabled to multiple components inside the rack. Servers in the rack can be programmed to illuminate the beacon in response to any detected problems or changes in status. The Rack Status Beacon has redundant AC power inputs and draws its power from the rack Power Distribution Unit (PDU) outlets. At least one #6095 power cord must be ordered to connect the Rack Status Beacon to the PDU.

  • Attributes provided: Indication of rack status
  • Attributes required: Junction box (#4693) and at least 2 cables (#4691); one or two #6095 power cords
  • For 7014-T42: (#4690)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No
(#4691) Rack Status Beacon Cable, Junction Box To Drawer Or Status Beacon

(No Longer Available as of November 18, 2005)

This cable can be used to connect the Rack Status Beacon Junction Box to a supported rack drawer or to the Rack Status Beacon.

  • Attributes provided: Connection between Rack Status Beacon components
  • Attributes required: None
  • For 7014-T42: (#4691)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No
(#4692) Rack Status Beacon Cable, Junction Box Daisy Chain

(No Longer Available as of March 31, 2006)

This cable is used to connect two Rack Status Beacon Junction Boxes (#4693) together. Multiple Junction Boxes may be linked in series, as required.

  • Attributes provided: Connection between (#4693) Junction Boxes
  • Attributes required: Two or more (#4693) Junction Boxes
  • For 7014-T42: (#4692)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No
(#4693) Rack Status Beacon Junction Box

(No Longer Available as of November 18, 2005)

This feature provides six input connectors and one output connector for racks configured with the Rack Status Beacon (#4690). Multiple Junction Boxes can be linked together in series with Daisy Chain Cable #4692.

  • Attributes provided: Connection of multiple drawers to a single Rack Status Beacon (#4690).
  • Attributes required: Feature #4690 and two or more #4691 cables.
  • For 7014-T42: (#4693)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No
(#5001) Customer Service Specify

This feature code specifies that the system will receive special request services from the Customer Solution Center (CSC).

  • Attributes provided: Customization
  • Attributes required: None
  • For 7014-T42: (#5001)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
(#5524) RFID TAGS FOR SERVERS, BLADES, BLADECENTERS, RACKS, AND HMCS

The specify feature attaches one Radio Frequency Identification Device (RFID) tag to a Server CEC, rack, HMC, Blade or Bladecenter enclosure. This can be used with MTM (machine type model) rack such as a 7014-T42, not a feature code rack such as a #0553. It applies to newly shipped MTM servers, racks, HMCs, Blades or Bladecenter enclosures, not MES orders with one exception. POWER5 CECs being upgraded to a POWER6 CEC can order this feature. The RFID tag meets the Financial Services Technology Consortium (FSTC) specifications for IT Data Center Asset Tracking.

  • Attributes provided: RFIDs
  • Attributes required: Server CEC, Blade, Bladecenter, MTM Rack, or HMC
  • For 7014-T42: (#5524)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: No
(#5889) Intelligent PDU+, base option, 1 EIA Unit, Universal, UTG0247 Connector

This feature is for an intelligent AC power distribution unit (PDU+) that will allow the user to monitor the amount of power being used by the devices that are plugged in to this PDU+. This AC power distribution unit provides twelve C13 power outlets. It receives power through a UTG0247 connector. It can be used for many different countries and applications by varying the PDU to Wall Power Cord, which must be ordered separately. Each PDU requires one PDU to Wall Power Cord. Supported power cords include the following features: #6489, #6491, #6492, #6653, #6654, #6655, #6656, #6657, and #6658. This feature should be used only to replace the initial standard PDU, feature 9188, in the base rack definition. This PDU+ is added as a second or greater PDU to a rack by ordering feature 7109.

  • Attributes provided: Twelve C13 power outlets with Power Monitoring Capability
  • Attributes required: PDU to wall power cord - exchange for base PDU 9188 only
  • For 7014-T42: (#5889)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: No
(#6069) - Front Door For 2.0 Meter Rack (High Perforation)

This feature provides an attractive black full height rack door. The door is steel, with a perforated flat front surface. The perforation pattern extends from the bottom to the top of the door to enhance ventilation and provide some visibility into the rack. This door hinges on the left side. ("Left" is as you face the door from the outside of the rack).

  • Attributes provided: Front door
  • Attributes required: None
  • For 7014-T42: (#6069)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#6080) Ruggedized Rack Feature

For enhanced rigidity and stability of the rack, the optional Ruggedized Rack Feature provides additional hardware that reinforces the rack and anchors it to the floor. This hardware is designed primarily for use in locations where earthquakes are a concern. The feature includes a large steel brace or truss that bolts into the rear of the rack. It is hinged on the left side so it can swing out of the way for easy access to the rack drawers when necessary. The Ruggedized Rack Feature also includes hardware for bolting the rack to a concrete floor or a similar surface, and bolt-in steel filler panels for any unoccupied spaces in the rack.

Note: If optional ruggedized rack feature number 6080 is installed, a tool will be required to remove the bolt to secure the side cover to the rack.

  • Attributes provided: Rear brace, bolt down hardware, bolt in front filler panels
  • Attributes required: None
  • For 7014-T42: (#6080)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
  • Limitations:
    • Feature #6080 should not be used with Power E870/E880 system nodes due to lack of cable room near braces. Use the newer #ERGC rugged rack feature instead.
    • Feature #ERG0 8-inch rear extension is not supported with #6080.
(#6081) Front Trim Kit For 2.0 Meter Rack (Black)

(No Longer Available as of September 24, 2004)

The front trim kit consists of three steel parts that snap into the front of the rack at the left, right, and top edges. They are painted to match the overall rack color and designed to present an attractive, finished appearance. Each rack must be ordered with either a front door or a front trim kit, but not both.

  • Attributes provided: Front trim kit
  • Attributes required: None
  • For 7014-T42: (#6081)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
(#6082) Front Trim Kit For 2.0 Meter Rack (White)

(No Longer Available as of December 31, 2001)

The front trim kit consists of three steel parts that snap into the front of the rack at the left, right, and top edges. They are painted to match the overall rack color and designed to present an attractive, finished appearance. Each rack must be ordered with either a front door or a front trim kit, but not both.

  • Attributes provided: Front trim kit
  • Attributes required: None
  • For 7014-T42: (#6082)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
(#6083) Front Door For 2.0 Meter Rack (Black)

(No Longer Available as of December 3, 2001)

This feature provides an attractive full height rack door. The door is steel and has an extensive perforation pattern that allows ventilation and some visibility into the rack.

  • Attributes provided: Front door
  • Attributes required: None
  • For 7014-T42: (#6083)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
(#6084) Front Door For 2.0M OEM Rack (Black)

This feature provides an attractive full height rack door. The door is steel and has an extensive performation pattern that allows ventilation and some visibility into the rack.

  • Attributes provided: Front Door
  • Attributes required: None
  • For 7014-T42: (#6084)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#6086) Suite Attach Kit For 2.0 Meter Rack (Black)

This feature allows a row of racks without side panels to be bolted together in a continuous suite, using the provided side to side rack connecting hardware. When multiple racks are joined in this way, cables can be easily run between racks without having to exit the continuous rack enclosure. A small gap is maintained between the two adjacent racks, which is filled by three matching steel trim pieces that snap into place on the front, top, and rear, between each rack. The trim pieces cover the space between each rack for an enhanced appearance and for additional protection of the equipment inside the racks. Side panels are needed only for the two end racks of the suite.

  • Attributes provided: Hardware and trim to attach two racks
  • Attributes required: None
  • For 7014-T42: (#6086)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
(#6087) Suite Attach Kit For 2.0 Meter Rack (White)

(No Longer Available as of December 31, 2001)

This feature allows a row of racks without side panels to be bolted together in a continuous suite, using the provided side to side rack connecting hardware. When multiple racks are joined in this way, cables can be easily run between racks without having to exit the continuous rack enclosure. A small gap is maintained between the two adjacent racks, which is filled by three matching steel trim pieces that snap into place on the front, top, and rear, between each rack. The trim pieces cover the space between each rack for an enhanced appearance and for additional protection of the equipment inside the racks. Side panels are needed only for the two end racks of the suite.

  • Attributes provided: Hardware and trim to attach two racks
  • Attributes required: None
  • For 7014-T42: (#6087)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
(#6089) Front Door for 2.0 Meter Rack (Sculptured Black)

(No Longer Available as of November 29, 2002)

This feature provides an attractive full height rack door. The door is black with sculptured accents. The door has an extensive perforation pattern that allows ventilation with some visibility into the rack.

  • Attributes provided: Front Door
  • Attributes required: None
  • For 7014-T42: (#6089)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
(#6095) Power Cord for PDU to External I/O Device

This feature provides a line cord to power an external I/O device from the power distribution unit of the rack.

  • Attributes provided: None
  • Attributes required: None
  • For 7014-T42: (#6095)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
(#6098) Side Panel For 1.8 or 2.0 Meter Rack (Black)

This feature provides one rack side panel, which can be used on either the left side or the right side of the rack. A typical rack will require a quantity of two side panels, unless the Rack Suite Attachment feature is ordered. Rack side panels can be quickly installed or removed from the outside the rack, with no tools required.

  • Attributes provided: One rack side panel
  • Attributes required: None
  • For 7014-T42: (#6098)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
(#6099) Side Panel For 1.8 Or 2.0 Meter Rack (White)

(No Longer Available as of December 27, 2002)

This feature provides one rack side panel, which can be used on either the left side or the right side of the rack. A typical rack will require a quantity of two side panels, unless the Rack Suite Attachment feature is ordered. Rack side panels can be quickly installed or removed from the outside the rack, with no tools required.

  • Attributes provided: One rack side panel
  • Attributes required: None
  • For 7014-T42: (#6099)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
(#6171) Power Distribution Unit - Side Mount, Single Phase

(No Longer Available as of June 25, 2004)

This optional, additional, AC power distribution unit is available for systems requiring two separate AC power sources or for systems that require more than six power outlets. This unit is the same as the base unit (#9171). An additional line cord is provided with this unit. Do not increase the quantity of the line cord specify code

  • Attributes provided: Additional AC power distribution
  • Attributes required:
  • For 7014-T42: (#6171)
    • Minimum required: 0
    • Maximum allowed: 6 (Initial order maximum: 6)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both

Note: First 3 Power Distribution Units (PDU) ordered with this feature number will be mounted in the back of the rack. Second 3 will be mounted horizontally in the rear of the rack, and will occupy 1U of rack space for each PDU.

(#6173) Power Distribution Unit - Side Mount, Two Of Three Phase

(No Longer Available as of June 25, 2004)

This optional, additional, AC power distribution unit is available for systems requiring two separate AC power sources or for systems that require more than six power outlets. This unit is the same as the base unit (#9173). An additional line cord is provided with this unit. Do not increase the quantity of the line cord specify code

  • Attributes provided: Additional AC power distribution
  • Attributes required:
  • For 7014-T42: (#6173)
    • Minimum required: 0
    • Maximum allowed: 6 (Initial order maximum: 6)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both

Note: First 3 Power Distribution Units (PDU) ordered with this feature number will be mounted in the back of the rack. Second 3 will be mounted horizontally in the rear of the rack, and will occupy 1U of rack space for each PDU.

(#6238) - High-end Appearance Side Covers

This feature provides side covers designed to be used when the rack will contain a 9179-MHB.

  • Attributes provided: Side covers for 2.0 meter IBM rack
  • Attributes required: None
  • For 7014-T42: (#6238)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: n/a
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#6247) Thin Profile Front Trim Kit For 2.0 Meter Rack (Black)

(No Longer Available as of May 28, 2010)

The front trim kit consists of three steel parts that snap into the front of the rack at the left, right, and top edges. They are painted to match the overall rack color and designed to present an attractive, finished appearance. Each rack must be ordered with either a front door or a front trim kit, but not both.

  • Attributes provided: Front trim kit
  • Attributes required: None
  • For 7014-T42: (#6247)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1 )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

    Note: Feature 6247 replaces the earlier feature 6081 trim kit. Either feature may be installed on a 7014-T42 rack, unless the rack contains a 9117-570 or 9117-MMA system. Models 570 and MMA are not compatible with the 6081 trim kit.

(#6249) - Acoustic Rack Doors, Front and Rear, 2.0 M

This feature provides front and rear rack doors designed to reduce acoustic sound levels in a general business environment. This door hinges on the left side. ("Left" is as you face the door from the outside of the rack).

  • Attributes provided: Front and rear acoustic doors for 2.0 meter IBM rack
  • Attributes required: None
  • For 7014-T42: (#6249)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1 )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#6250) - HIGH-END APPEARANCE FRONT DOOR

(No Longer Available as of August 31, 2017)

This feature provides a front rack door with a field installed Power 780 logo designed to be used when the rack will contain a 9179-MHB. This door hinges on the left side. ("Left" is as you face the door from the outside of the rack).

  • Attributes provided: Front door for 2.0 meter IBM rack
  • Attributes required: None
  • For 7014-T42: (#6250)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: n/a
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#6257) Rack Extender

(No Longer Available as of February 24, 2015)

The rack extender #6257 for the 7014-T42, provides the required cable management for the 7874-120 QLogic 9120 144-port DDR InfiniBand Fabric Director Switch, and the 7874-240 QLogic 9240 288-port DDR InfiniBand Fabric Director Switch. The rack extender is 20 inches deep.

  • For 7014-T42: (#6257)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No
(#6272) - 2.0m Rack Trim Kit

This feature provides a decorative trim kit for the front of feature number 0553 (19 inch 2.0m Rack).

  • Attributes provided: Decorative trim kit
  • Attributes required: #0553 19 inch 2.0 meter Rack
  • For 7014-T42: (#6272)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES:
(#6442) Power Cord, 7176/9176 PDU To Wall, 9800/9824 Equivalent

(No Longer Available as of June 23, 2006)

This feature provides the same power cord for a PDU that is provided when feature #9800 or #9824 is specified in the initial rack order.

  • Attributes provided: Power cord
  • Attributes required: One phase power
  • For 7014-T42: (#6442)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: 0 )
    • OS level required: None
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes
    • Return parts MES: No
(#6443) Power Cord, 7176/9176 PDU To Wall, 9801 Equivalent

(No Longer Available as of June 23, 2006)

This feature provides the same power cord for a PDU that is provided when feature #9801 is specified in the initial rack order.

  • Attributes provided: Power cord
  • Attributes required: One phase power
  • For 7014-T42: (#6443)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: 0 )
    • OS level required: None
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes
    • Return parts MES: No
(#6444) Power Cord, 7176/9176 PDU To Wall, 9822 Equivalent

(No Longer Available as of June 23, 2006)

This feature provides the same power cord for a PDU that is provided when feature #9822 is specified in the initial rack order.

  • Attributes provided: Power cord
  • Attributes required: One phase power
  • For 7014-T42: (#6444)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: 0 )
    • OS level required: None
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes
    • Return parts MES: No
(#6445) Power Cord, 7177/9177 PDU To Wall, 9823 Equivalent

(No Longer Available as of June 23, 2006)

This feature provides the same power cord for a PDU that is provided when feature #9823 is specified in the initial rack order.

  • Attributes provided: Power cord
  • Attributes required: One phase power
  • For 7014-T42: (#6445)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: 0 )
    • OS level required: None
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes
    • Return parts MES: No
(#6447) Power Cord, 7176/9176 PDU To Wall, 9826 Equivalent

(No Longer Available as of June 23, 2006)

This feature provides the same power cord for a PDU that is provided when feature #9826 is specified in the initial rack order.

  • Attributes provided: Power cord
  • Attributes required: One phase power
  • For 7014-T42: (#6447)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: 0 )
    • OS level required: None
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes
    • Return parts MES: No
(#6448) Power Cord, 7176/9176 PDU To Wall, 9835 Equivalent

(No Longer Available as of June 23, 2006)

This feature provides the same power cord for a PDU that is provided when feature #9835 is specified in the initial rack order.

  • Attributes provided: Power cord
  • Attributes required: One phase power
  • For 7014-T42: (#6448)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: 0 )
    • OS level required: None
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes
    • Return parts MES: No
(#6449) Power Cord, 7176/9176 PDU To Wall, 9986 Equivalent

(No Longer Available as of June 23, 2006)

This feature provides the same power cord for a PDU that is provided when feature #9986 is specified in the initial rack order.

  • Attributes provided: Power cord
  • Attributes required: One phase power
  • For 7014-T42: (#6449)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: 0 )
    • OS level required: None
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes
    • Return parts MES: No
(#6450) Power Cord, 7176/9176 PDU To Wall, 9987 Equivalent

(No Longer Available as of June 23, 2006)

This feature provides the same power cord for a PDU that is provided when feature #9987 is specified in the initial rack order.

  • Attributes provided: Power cord
  • Attributes required: One phase power
  • For 7014-T42: (#6450)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: 0 )
    • OS level required: None
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes
    • Return parts MES: No
(#6489) Power Cord, 7188/9188 PDU To Wall, 4.3M, 24A, IEC 309 3P+N+G 32A Plug

This power cord provides power to a #7188 or #9188 power distribution unit. It connects to a wall power outlet with an IEC 309 3P+N+G 32A plug.

  • Attributes provided: Power connection for a #7188 or #9188 PDU
  • Attributes required: None
  • For 7014-T42: (#6489)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#6491) - 4.3m (14-Ft) 1PH/63A 200-240V Power Cord

#6491 is a 14-FT/4.3m 200-240V/63A power cord with a Type 46 plug which distributes power from a power source to a Power Distribution Unit.

  • Attributes provided: Power connection for a #7188 or #9188 PDU
  • Attributes required: None
  • For 7014-T42: (#6491)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#6492) Power Cord, 7188/9188 PDU To Wall, 4.3M, 48A, IEC 309 2P+G 60APlug

This power cord provides power to a #7188 or #9188 power distribution unit. It connects to a wall power outlet with an IEC 309 2P+G 60A plug.

  • Attributes provided: Power connection for a #7188 or #9188 PDU
  • Attributes required: None
  • For 7014-T42: (#6492)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#6546) White Rack Option, Factory Only

(No Longer Available as of December 10, 2004)

The standard color for racks is black. Racks ordered with this feature will be white.

  • Attributes provided: White rack color replaces standard black
  • Attributes required: None
  • For 7014-T42: (#6546)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#6580) Rack Security Kit

This feature provides hardware that can be added to a rack to prevent unauthorized access. It includes keyed front and rear locks for the standard door latches. It also includes two sliding bars that mount inside the left and right rack side panels. The sliding bars are accessible when the rack rear door is open. They can be moved to a position that disables the external latches on the rack side panels, and prevents removal of the side panels.

  • Attributes provided: Locking hardware for rack doors and side panels
  • Attributes required: None
  • For 7014-T42: (#6580)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#6586) Modem Tray For 19-Inch Rack

(No Longer Available as of December 29, 2017)

This feature provides hardware for installing one or two modems in a 19-inch rack. The modem tray occupies 1U of rack space when it is mounted in the front of the rack. It provides a secure location in the rack for modems attached to 7315 Hardware Management Consoles.

  • Attributes provided: Space for two modems
  • Attributes required: IBM 7014 rack with 1U available
  • For 7014-T42: (#6586)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#6653) Power Cord, 7188/9188 PDU To Wall, 4.3M, 16A, IEC 309 3P+N+G 16A Plug

This power cord provides power to a #7188 or #9188 power distribution unit. It connects to a wall power outlet with an IEC 309 3P+N+G 16A plug.

  • Attributes provided: Power connection for a #7188 or #9188 PDU
  • Attributes required: None
  • For 7014-T42: (#6653)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#6654) Power Cord, 7188/9188 PDU To Wall, 4.3M, 24A, NEMA L6-30 Plug

This power cord provides power to a #7188 or #9188 power distribution unit. It connects to a wall power outlet with a NEMA L6-30 plug.

  • Attributes provided: Power connection for a #7188 or #9188 PDU
  • Attributes required: None
  • For 7014-T42: (#6654)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#6655) Power Cord, 7188/9188 PDU To Wall, 4.3M, 24A, RS 3750DP (Watertight) Plug

This power cord provides power to a #7188 or #9188 power distribution unit. It connects to a wall power outlet with an RS 3750DP (watertight) plug.

  • Attributes provided: Power connection for a #7188 or #9188 PDU
  • Attributes required: None
  • For 7014-T42: (#6655)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#6656) Power Cord, 7188/9188 PDU To Wall, 4.3M, 24A, IEC 309 P+N+G 32A Plug

This power cord provides power to a #7188 or #9188 power distribution unit. It connects to a wall power outlet with an IEC 309 P+N+G 32A plug.

  • Attributes provided: Power connection for a #7188 or #9188 PDU
  • Attributes required: None
  • For 7014-T42: (#6656)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#6657) - 4.3m (14-Ft) 1PH/32A Power Cord

#6657 is a 14-FT/4.3m 1PH/32A power cord with a Type PDL plug which distributes power from a power source to a Power Distribution Unit.

  • Attributes provided: Power connection for a #7188 or #9188 PDU
  • Attributes required: None
  • For 7014-T42: (#6657)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#6658) Power Cord, 7188/9188 PDU To Wall, 4.3M, 24A, Korean Plug

This power cord provides power to a #7188 or #9188 power distribution unit. It connects to a wall power outlet with a Korean plug.

  • Attributes provided: Power connection for a #7188 or #9188 PDU
  • Attributes required: None
  • For 7014-T42: (#6658)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#6667) - 4.3m (14-Ft) 3PH/32A Pwr Cd-Australia

#6667 is a 14-FT/4.3m 200-240V/24A power cord with a Type PDL plug which distributes power from a power source to a Power Distribution Unit.

  • Attributes provided: PDU power cable
  • Attributes required: None
  • For 7014-T42: (#6667)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#6858) - Rear Door Heat Exchanger

Rear Door Heat Exchanger. This door replaces the standard rear door on the rack. Copper tubes attached to the rear door circulate chilled water, provided by the customer. The chilled water removes heat from the exhaust air being blown through the Servers and Attachments mounted in the Rack. The water lines in the door attached to the customer supplied secondary water loop using industry standard quick couplings. This door hinges on the left side. ("Left" is as you face the door from the outside of the rack).

  • Attributes provided: One rear heat eXchanger door
  • Attributes required: One 7014-T42/B42 rack
  • For 7014-T42: (#6858)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1 )
    • OS level required: none
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#6860) Mounting hardware kit

(No Longer Available as of June 23, 2006)

This feature delivers the required nut clips and screws to mount the 7048-120 or the 7048-270 into a rack.

  • Attributes provided: Mounting hardware kit
  • Attributes required: None
  • For 7014-T42: (#6860)
    • Minimum required: 0
    • Maximum allowed: 39 (Initial order maximum: 39 )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#7109) Intelligent PDU+, 1 EIA Unit, Universal, UTG0247 Connector

This feature is for an intelligent AC power distribution unit (PDU+) that will allow the user to monitor the amount of power being used by the devices that are plugged in to this PDU+. This AC power distribution unit provides twelve C13 power outlets. It receives power through a UTG0247 connector. It can be used for many different countries and applications by varying the PDU to Wall Power Cord, which must be ordered separately. Each PDU requires one PDU to Wall Power Cord. Supported power cords include the following features: #6489, #6491, #6492, #6653, #6654, #6655, #6656, #6657, and #6658.

  • Attributes provided: Twelve C13 outlets with Power Monitoring Capability
  • Attributes required: PDU to Wall power cord
  • For 7014-T42: (#7109)
    • Minimum required: 0
    • Maximum allowed: no max (Initial order maximum: no max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

    Note: When purchased on an Initial order rack. This PDU will be mounted in the rear side pockets until all 4 side pockets on the rack have been filled. Any additional PDUs on the order will be mounted in 1 unit of EIA rack space.

    When purchased as an MES for addition to a rack in the field. This PDU may not fit in the side pockets of the 7014-T42 rack due to a hardware interference with the rack, and may require mounting in 1 unit of rack EIA space. Insure rack space is available before placing the MES order for this PDU.

(#7118) - Environmental Monitoring Probe

The Environmental Monitoring Probe (EMP) enables you to remotely monitor environmental conditions. Using a standard web browser, you can view the ambient temperature and humidity of the remote environment, as well as the status of two additional contact devices, such as a smoke detector or open-door sensor. The temperature/humidity probe plugs into a RJ45 connector an a PDU+. The EMP can be used with any Powerware UPS equipped with a 10/100 Mb ConnectUPS Web/SNMP Card (firmware V3.01 or higher). The EMP can be located up to 20m (65.6 feet) away.

  • Attributes provided: Monitoring of temperature, humidity, and status of two contacts/ sensors. A one meter cat5 Ethernet cable, double sided velcro tape, two tie-wraps, and screw with wall anchor for mounting.
  • Attributes required: None
  • For 7014-T42: (#7118)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 8)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#7176) Power Distribution Unit - Side Mount, Single Phase, L6-30 Connector

(No Longer Available as of March 31, 2005)

This optional, additional, AC power distribution unit is available for systems requiring two separate AC power sources or for systems that require more than nine power outlets. This unit is the same as the base unit (#9176), and it provides nine C13 power outlets. An additional line cord is provided with this unit. Do not increase the quantity of the line cord specify code.

  • Attributes provided: 9 C13 power outlets
  • Attributes required: None
  • For 7014-T42: (#7176)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 8)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

Note: First 3 Power Distribution Units (PDU) ordered with this feature number will be mounted vertically in the back of the rack. Any additional PDUs will be mounted horizontally in the rear of the rack, and will occupy 1U of rack space for each PDU.

(#7177) Power Distribution Unit - Side Mount, Single Phase, IEC-309 Connector

(No Longer Available as of March 31, 2005)

This optional, additional, AC power distribution unit is available for systems requiring two separate AC power sources or for systems that require more than nine power outlets. This unit is the same as the base unit (#9177), and it provides nine C13 power outlets. An additional line cord is provided with this unit. Do not increase the quantity of the line cord specify code.

  • Attributes provided: Nine C13 power outlets
  • Attributes required: None
  • For 7014-T42: (#7177)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 8)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

Note: First 3 Power Distribution Units (PDU) ordered with this feature number will be mounted vertically in the back of the rack. Any additional PDUs will be mounted horizontally in the rear of the rack, and will occupy 1U of rack space for each PDU.

(#7178) Power Distribution Unit - Side Mount, Three Phase, IEC-309 Connector

(No Longer Available as of March 31, 2005)

This optional, additional, AC power distribution unit is available for systems requiring two separate AC power sources or for systems that require more than nine power outlets. This unit is the same as the base unit (#9178), and it provides nine C13 power outlets. An additional line cord is provided with this unit. Do not increase the quantity of the line cord specify code.

  • Attributes provided: Nine C13 power outlets
  • Attributes required: None
  • For 7014-T42: (#7178)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 8)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

Note: First 3 Power Distribution Units (PDU) ordered with this feature number will be mounted vertically in the back of the rack. Any additional PDUs will be mounted horizontally in the rear of the rack, and will occupy 1U of rack space for each PDU.

(#7188) Power Distribution Unit - Side Mount, Universal, UTG0247 Connector

This optional, additional, AC power distribution unit is available for systems requiring two separate AC power sources or for systems that require more than twelve power outlets. This unit is the same as the base unit (#9188), and it provides twelve C13 power outlets.

  • Attributes provided: Twelve C13 power outlets
  • Attributes required: PDU to Wall Power Cord #6489, #6491, #6492, #6653, #6654, #6655, #6656, #6657, or #6658
  • For 7014-T42: (#7188)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

    Note: The first 4 Power Distribution Units (PDU) ordered for a rack will be mounted vertically in the sides of the rack, occupying the four PDU bays. Any additional PDUs will be mounted horizontally in the rear of the rack, and will occupy 1U of rack space for each PDU.

(#7196) Power Distribution Unit (US) - 1 EIA Unit, Universal, Fixed Power Cord

This AC power distribution unit provides six C19 power outlets. Fixed power cord (IEC309 60A plug (3P+G). This PDU requires 3-phase electrical service. US only.

  • Attributes provided: Six C19 power outlets
  • Attributes required: 3 phase electical service
  • For 7014-T42: (#7196)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#9002) Field Integration Indicator, Ship Empty Rack

This feature on an order identifies that IBM manufacturing must ship the rack without installing any rack mount drawers. Exactly one feature selection from the set 9002 and 4651 through 4666 must be included on all initial rack orders. Feature 9002, when placed on an order will not affect the assembly of hardware items ordered as rack feature codes. When #9002 is included on the rack order, rack content specify codes should be included for any systems that will be installed in the rack after it leaves the factory.

  • Attributes provided: Initial Rack order shipped without rack mount drawers.
  • Attributes required: Machine Type Rack order
  • For 7014-T42: (#9002)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#9169) Order Routing Indicator - System Plant

This feature will be auto-selected by the Configurator Tool when required. Use of this feature will affect the routing of the order. Selection of this indicator will direct the order to a system plant for fulfillment.

  • Attributes provided: None
  • Attributes required: None
  • For 7014-T42: (#9169)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1 )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#9171) Power Distribution Unit Specify - Base/Side Mount, Single Phase

(No Longer Available as of June 25, 2004)

  • Attributes provided: AC power distribution, 6 power outlets.
  • Attributes required: None
  • For 7014-T42: (#9171)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#9173) Power Distribution Unit Specify - Base/Side Mount, Two Of Three Phase

(No Longer Available as of June 25, 2004)

  • Attributes provided: AC power distribution, 6 outlets
  • Attributes required: None
  • For 7014-T42: (#9173)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#9176) Power Distribution Unit Specify - Base/Side Mount, Single Phase, L6-30 Connector

(No Longer Available as of March 31, 2005)

This AC power distribution unit provides nine C13 power outlets.

  • Attributes provided: Nine C13 power outlets
  • Attributes required: None
  • For 7014-T42: (#9176)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#9177) Power Distribution Unit Specify - Base/Side Mount, Single Phase, IEC-309 Connector

(No Longer Available as of March 31, 2005)

This AC power distribution unit provides nine C13 power outlets.

  • Attributes provided: Nine C13 power outlets
  • Attributes required: None
  • For 7014-T42: (#9177)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#9178) Power Distribution Unit Specify - Base/Side Mount, Three Phase, IEC-309 Connector

(No Longer Available as of March 31, 2005)

This AC power distribution unit provides nine C13 power outlets.

  • Attributes provided: Nine C13 power outlets
  • Attributes required: None
  • For 7014-T42: (#9178)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply
(#9188) Power Distribution Unit Specify - Base/Side Mount, Universal, UTG0247 Connector

This AC power distribution unit provides twelve C13 power outlets. It receives power through a UTG0247 connector. It can be used for many different countries and applications by varying the PDU to Wall Power Cord, which must be ordered separately. Each PDU requires one PDU to Wall Power Cord. Supported power cords include the following features: #6489, #6491, #6492, #6653, #6654, #6655, #6656, #6657, and #6658.

  • Attributes provided: Twelve C13 power outlets
  • Attributes required: PDU to Wall Power Cord #6489, #6491, #6492, #6653, #6654, #6655, #6656, #6657, or #6658
  • For 7014-T42: (#9188)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1 )
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Does not apply
    • Return parts MES: Does not apply

    Note: The first 4 Power Distribution Units (PDU) ordered for a rack will be mounted vertically in the sides of the rack, occupying the four PDU bays. Any additional PDUs will be mounted horizontally in the rear of the rack, and will occupy 1U of rack space for each PDU.

(#9300) Language Group Specify - US English

English language group for nomenclature and standard publications.

  • Attributes provided: None
  • Attributes required: None
  • For 7014-T42: (#9300)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#9459) - PDU/PWR and Power Cord Redundancy Assurance

Feature 9459 facilitates matching up paired PDU, power supplies, and line cords for rack level redundancy. Including #9459 rectify the PDU, power supplies, and line cords? pairing for the configuration process and prevents manufacturing interruptions for improper quantities.

  • Attributes provided: Redundant PDU, power supplies and line cords within the Rack.
  • Attributes required: Rack
  • For 7014-T42: (#9459)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9461) - Month Indicator

Administrative indicator used to enable configuration of orders with a total quantity greater than thirty to be processed.

  • Attributes provided: None
  • Attributes required: None
  • For 7014-T42: (#9461)
    • Minimum required: 0
    • Maximum allowed: 12 (Initial order maximum: 12)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9462) - Day Indicator

Administrative indicator used to enable configuration of orders with a total quantity greater than thirty to be processed.

  • Attributes provided: None
  • Attributes required: None
  • For 7014-T42: (#9462)
    • Minimum required: 0
    • Maximum allowed: 31 (Initial order maximum: 31)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9463) - Hour Indicator

Administrative indicator used to enable configuration of orders with a total quantity greater than thirty to be processed.

  • Attributes provided: None
  • Attributes required: None
  • For 7014-T42: (#9463)
    • Minimum required: 0
    • Maximum allowed: 24 (Initial order maximum: 24)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9464) - Minute Indicator

Administrative indicator used to enable configuration of orders with a total quantity greater than thirty to be processed.

  • Attributes provided: None
  • Attributes required: None
  • For 7014-T42: (#9464)
    • Minimum required: 0
    • Maximum allowed: 60 (Initial order maximum: 60)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9465) - Qty Indicator

This quantity indicator is used to specify the remaining, or N-1 quantity of CFR entities that need to be accumulated for rejoining. The quantity ordered for this feature is generated by eConfig. and is equal to N-1, where 'N' equals the total quantity of CFRs being rejoined.

  • Attributes provided: None
  • Attributes required: None
  • For 7014-T42: (#9465)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9466) - Countable Member Indicator

This administrative indicator used to identify each CFR associated with a date/time stamp that is eligible for splitting and rejoining. The quantity ordered for this feature is generated by eConfig.

  • Attributes provided: None
  • Attributes required: None
  • For 7014-T42: (#9466)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9703) Language Group Specify - French

French language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 7014-T42: (#9703)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#9704) Language Group Specify - German

German language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 7014-T42: (#9704)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#9705) Language Group Specify - Polish

Polish language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 7014-T42: (#9705)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#9707) Language Group Specify - Portuguese

Portuguese language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 7014-T42: (#9707)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#9708) Language Group Specify - Spanish

Spanish language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 7014-T42: (#9708)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#9711) Language Group Specify - Italian

Italian language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 7014-T42: (#9711)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#9712) Language Group Specify - Canadian French

Canadian French language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 7014-T42: (#9712)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#9714) Language Group Specify - Japanese

Japanese language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 7014-T42: (#9714)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#9716) Language Group Specify - Korean

Korean language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 7014-T42: (#9716)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#9719) Language Group Specify - Hungarian

Hungarian language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 7014-T42: (#9719)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#9720) Language Group Specify - Slovakian

Slovakian language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 7014-T42: (#9720)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#9721) Language Group Specify - Russian

Russian language group for nomenclature and standard publications.

  • Attributes provided: None
  • Attributes required: None
  • For 7014-T42: (#9721)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#9722) Language Group Specify - Simplified Chinese (PRC)

Simplified Chinese language group for nomenclature and standard publications.

  • Attributes provided: None
  • Attributes required: None
  • For 7014-T42: (#9722)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
(#9800) Power Cord Specify - United States/Canada

(No Longer Available as of March 31, 2005)

The following countries use the #9800 power cord to power the system unit and/or peripheral features requiring a power cord.

  • DOM US
  • 649 CANADA
  • 832 SAUDI ARABIA
  • 619 BAHAMAS
  • 621 BARBADOS
  • 627 BERMUDA
  • 629 BOLIVIA
  • 631 BRAZIL
  • 661 COLOMBIA
  • 663 COSTA RICA
  • 681 DOMINICAN REPUBLIC
  • 683 ECUADOR
  • 829 EL SALVADOR
  • 731 GUATEMALA
  • 640 GUYANA
  • 735 HONDURAS
  • 759 JAMAICA
  • 781 MEXICO
  • 791 NETHERLANDS ANTILLES
  • 811 PANAMA
  • 843 SURINAM
  • 859 TRINIDAD
  • 871 VENEZUELA
  • 760 JAPAN
  • 761 JAPAN (PDS)
  • 766 KOREA
  • 818 PHILIPPINES
  • 858 TAIWAN
  • Attributes provided: Power cord
  • Attributes required: None
  • For 7014-T42: (#9800)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
(#9801) Power Cord Specify - Raised Floor (US)

(No Longer Available as of March 31, 2005)

The #9801 power cord is used to power the system unit in a raised floor environment. When #9801 is ordered, the power cord includes a waterproof connector.

  • Attributes provided: None
  • Attributes required: One phase power
  • For 7014-T42: (#9801)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
(#9822) Power Cord Specify - Australia

(No Longer Available as of March 31, 2005)

The following countries use power cord #9822 to power the system unit:

  • 616 AUSTRALIA
  • Attributes provided: Power cord
  • Attributes required: One phase power
  • For 7014-T42: (#9822)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
(#9823) Power Cord Specify - EMEA (PDU)

(No Longer Available as of March 31, 2005)

The following countries use power cord #9823 to power the system unit:

  • 620 BAHRAIN (NEO)
  • 624 BELGIUM
  • 865 EGYPT
  • 706 FRANCE
  • 724 GERMANY, WEST
  • 723 GERMANY, WEST (PDS)
  • 726 GREECE
  • 742 ICELAND
  • 752 IRAQ
  • 754 IRELAND
  • 758 ITALY
  • 762 JORDAN
  • 767 KUWAIT
  • 768 LEBANON
  • 806 NORWAY
  • 805 OMAN (SULT)
  • 822 PORTUGAL
  • 823 QATAR
  • 832 SAUDI ARABIA
  • 838 SPAIN
  • 862 TURKEY
  • 680 UNITED ARAB EMIRATES
  • 866 UNITED KINGDOM
  • Attributes provided: Power cord
  • Attributes required: One phase power
  • For 7014-T42: (#9823)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
(#9824) Power Cord Specify - Japan and 60HZ AP

(No Longer Available as of March 31, 2005)

The following countries use power cord #9824 to power the system unit:

  • 613 ARGENTINA
  • 619 BAHAMAS
  • 621 BARBADOS
  • 627 BERMUDA
  • 629 BOLIVIA
  • 631 BRAZIL
  • 655 CHILE
  • 661 COLOMBIA
  • 663 COSTA RICA
  • 681 DOMINICAN REPUBLIC
  • 683 ECUADOR
  • 829 EL SALVADOR
  • 731 GUATEMALA
  • 640 GUYANA
  • 735 HONDURAS
  • 759 JAMAICA
  • 781 MEXICO
  • 791 NETHERLANDS ANTILLES
  • 811 PANAMA
  • 815 PERU
  • 843 SURINAM
  • 859 TRINIDAD
  • 869 URUGUAY
  • 871 VENEZULA
  • 615 BANGLADESH
  • 643 BRUNEI
  • 672 CHINA
  • 738 HONG KONG
  • 744 INDIA
  • 749 INDONESIA
  • 760 JAPAN
  • 761 JAPAN (PDS)
  • 766 KOREA
  • MACAO
  • 778 MALAYSIA
  • 646 MYANMAR (BURMA)
  • 818 PHILLIPINES
  • 834 SINGAPORE
  • 652 SRI LANKA
  • 858 TAIWAN
  • 856 THAILAND
  • Attributes provided: Power cord
  • Attributes required: One phase power
  • For 7014-T42: (#9824)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
(#9826) Power Cord Specify - New Zealand

(No Longer Available as of March 31, 2005)

The following countries use power cord #9826 to power the system unit:

  • 796 NEW ZEALAND
  • Attributes provided: Power cord
  • Attributes required: One phase power
  • For 7014-T42: (#9826)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
(#9835) Power Cord Specify - Korea (PDU)

(No Longer Available as of March 31, 2005)

  • Attributes provided: Power cord
  • Attributes required: One phase power
  • For 7014-T42: (#9835)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
(#9986) Power Cord Specify - Chicago (1.8M)(6 FT.)

(No Longer Available as of March 31, 2005)

The 6 foot #9986 power cord is used to power the system unit and/or peripheral features requiring a power cord.

  • Attributes provided: None
  • Attributes required: None
  • For 7014-T42: (#9986)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
(#9987) Power Cord Specify - Chicago (Raised Floor)

(No Longer Available as of March 31, 2005)

The #9987 power cord is used to power the system unit in a raised floor environment.

  • Attributes provided: None
  • Attributes required: One phase power
  • For 7014-T42: (#9987)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
(#B0LG) - ServicePac Not Selected

(No Longer Available as of February 24, 2016)

ServicePac services not selected for this configuration

  • For 7014-T42: (#B0LG)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#B0LH) - Service Renewal Requested

(No Longer Available as of February 24, 2016)

Service renewal requested upon expiration

  • For 7014-T42: (#B0LH)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#B0UW) - SP WAMO 3Y 24x7 SD

ServicePac Warranty and Maintenance Option 3 YR 24x7 Same Day ORT 6hrCL/ 4hrPD

  • For 7014-T42: (#B0UW)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

    Note: Not available in Japan

(#EB3Z) - Lift tool based on GenieLift GL-8 (standard)

This feature delivers the Low-Cost Lift Tool (based on GenieLift GL-8 (standard)) for IBM servers.

Feature #EB3Z is a feature that is available on multiple server types (POWER S812L, S822L, S824L, S814, S824, S812, S822, E850C, E850, E880C, E870C, E880, and E870, also the rack models 7965-S42, 7014-T00, and 7014-T42). Failure to have at least one Lift tool available in a location may result in delayed or prolonged maintenance times.

A lift tool raises and lowers servers and I/O drawers so they can be placed into or removed from standard 19-inch racks. It allows heavier equipment to be handled more safely by fewer people. Lift tool feature EB3Z has a hand crank to lift and position up to 181 kg (400 lbs). The lift tool feature EB3Z operating length and width are 88.3 cm x 62.9 cm (34 3/4 x 24 3/4 in). It has rollers which allow it to be moved to different racks in the data center.

  • Attributes provided: Lift Tool
  • Attributes required: None
  • For 7014-T42: (#EB3Z)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EBA5) - HVDC PDU Horizontal Mounting

Specify feature communicates to IBM Manufacturing that a HVDC DPU such as feature #EPAA or feature #EPAE should be horizontally mounted vs vertically mounted. PDU uses 1U rack space when horizontally mounted, but makes accessing power cords much easier than in a side pocket.

  • Attributes provided: Manufacturing communication information
  • Attributes required: HVDC PDU
  • For 7014-T42: (#EBA5)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required: None.
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EC07) - Slim Rear Acoustic Door

Black acoustic rear doors for a 2M rack. This door hinges on the left side. ("Left" is as you face the door from the outside of the rack).

  • Attributes provided: New design of acoustic rear door
  • Attributes required: 7014-T42 rack with a Power server
  • For 7014-T42: (#EC07)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EC08) - Slim Front Acoustic Door

Black acoustic front doors for a 2M rack. This door hinges on the left side. ("Left" is as you face the door from the outside of the rack).

  • Attributes provided: New design of acoustic front door
  • Attributes required: 7014-T42 rack with a Power server
  • For 7014-T42: (#EC08)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#ECS0) - Indicator Assembled and Tested in China

This is indicator that the product was assembled and tested in China.

  • Attributes provided: None
  • Attributes required: None
  • For 7014-T00: (#ECS0)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None.
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: No
  • For 7014-T42: (#ECS0)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None.
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: No
(#ECSC) - Custom Service Specify, Shenzhen, China

Having #ESCS on the order, will cause the order to be routed to Shenzhen and the machine to be internally routed to the CSC build area.

  • Attributes provided: Customization
  • Attributes required: None
  • For 7014-T42: (#ECSC)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: Does not apply
(#ECSF) - Custom Service Specify, Montpellier, France

Having #ECSF on the order, will cause the order to be routed to France and the machine to be internally routed to the CSC build area.

  • Attributes provided: Customization
  • Attributes required: None
  • For 7014-T42: (#ECSF)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#ECSJ) - NeuCloud Indicator/Specify

This is a no-charge specify code for helping IBM track orders for reporting purposes

  • Attributes provided: none
  • Attributes required: used in mainland China
  • For 7014-T42: (#ECSJ)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: No
(#ECSM) - Custom Service Specify, Mexico

Having #ESCM on the order, will cause the order to be routed to Mexico and the machine to be internally routed to the CSC build area.

  • Attributes provided: Customization
  • Attributes required: None
  • For 7014-T42: (#ECSM)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ECSP) - Custom Service Specify, Poughkeepsie, USA

Having #ECSP on the order, will cause the order to be routed to Poughkeepsie, USA and the machine to be internally routed to the CSC build area.

  • Attributes provided: Customization
  • Attributes required: None
  • For 7014-T42: (#ECSP)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: does not apply
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ECSS) - Integrated Solution Packing

This is a routing indicator for Solution packing.

  • Attributes provided: Routing instruction for manufacturing
  • Attributes required: None
  • For 7014-T42: (#ECSS)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#EDAN) - Analytics Data Node Add-on

This feature is not supported by the configurator or by the PureFlex System.

  • Attributes provided: None
  • Attributes required: None
  • For 7014-T42: (#EDAN)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EGSA) - IDEA Solution Specify

This feature indicates that this configuration is for IDEA Solution.

  • Attributes provided: #EGSA Specify
  • Attributes required: None
  • For 7014-T42: (#EGSA)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#EGSB) - SOLUTION SPECIFY

This feature is use to identify Solution selection for adminstrative purposes within manufacturing to Faciliate processing.

  • Attributes provided: #EGSB Specify
  • Attributes required: None
  • For 7014-T42: (#EGSB)
    • Minimum required: 0
    • Maximum allowed: 999 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: Does not apply
(#EGSC) - GL2 SOLUTION SPEC 2TB DCS370E

(No Longer Available as of January 24, 2017)

Specify GL2 (12U) Solution with 7.2K HDD 2TB + DC3700E.

  • Attributes provided: #EGSC Specify
  • Attributes required: None
  • For 7014-T42: (#EGSC)
    • Minimum required: 0
    • Maximum allowed: 3 (Initial order maximum: 3)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#EGSD) - GL4 SOLUTION SPEC 2TB DCS370E

(No Longer Available as of January 24, 2017)

Specify GL4 (20U) Solution with 7.2K HDD 2TB + DCS3700E.

  • Attributes provided: #EGSD Specify
  • Attributes required: None
  • For 7014-T42: (#EGSD)
    • Minimum required: 0
    • Maximum allowed: 999 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: Does not apply
(#EGSE) - GL6 SOLUTION SPEC 2TB DCS370E

(No Longer Available as of January 24, 2017)

Specify GL6 (28U) Solution with 7.2K HDD 2TB + DCS3700E.

  • Attributes provided: #EGSE Specify
  • Attributes required: None
  • For 7014-T42: (#EGSE)
    • Minimum required: 0
    • Maximum allowed: 999 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: Does not apply
(#EGSF) - GL2 SOLUTION SPEC 4TB DCS370E

Specify GL2 (12U) Solution with 7.2K HDD 4TB + DCS3700E.

  • Attributes provided: #EGSF Specify
  • Attributes required: None
  • For 7014-T42: (#EGSF)
    • Minimum required: 0
    • Maximum allowed: 3 (Initial order maximum: 3)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#EGSG) - GL4 SOLUTION SPEC 4TB DCS370E

Specify GL4 (20U) Solution with 7.2K HDD 4TB + DCS3700E.

  • Attributes provided: #EGSG Specify
  • Attributes required: None
  • For 7014-T42: (#EGSG)
    • Minimum required: 0
    • Maximum allowed: 999 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: Does not apply
(#EGSH) - GL6 SOLUTION SPEC 4TB DCS370E

Specify GL6 (28U) Solution with 7.2K HDD 4TB + DCS3700E.

  • Attributes provided: #EGSH Specify
  • Attributes required: None
  • For 7014-T42: (#EGSH)
    • Minimum required: 0
    • Maximum allowed: 999 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: Does not apply
(#EGSJ) - GS1 SOLUTION SPEC 400GB #EL1S

Specify GS1 (6U) Solution with 400GB SSD + EXP24S SFF Gen2-bay Drawer.

  • Attributes provided: #EGSJ Specify
  • Attributes required: None
  • For 7014-T42: (#EGSJ)
    • Minimum required: 0
    • Maximum allowed: 6 (Initial order maximum: 6)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#EGSK) - GS1 SOLUTION SPEC 800GB #EL1S

Specify GS1 (6U) Solution with 800GB SSD and EXP24S SFF Gen2-bay Drawer.

  • Attributes provided: #EGSK Specify
  • Attributes required: None
  • For 7014-T42: (#EGSK)
    • Minimum required: 0
    • Maximum allowed: 6 (Initial order maximum: 6)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#EGSL) - GS2 SOLUTION SPEC 400GB #EL1S

Specify GS2 (8U) Solution with 400GB SSD and EXP24S SFF Gen2-bay Drawer.

  • Attributes provided: #EGSL Specify
  • Attributes required: None
  • For 7014-T42: (#EGSL)
    • Minimum required: 0
    • Maximum allowed: 999 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: Does not apply
(#EGSM) - GS2 SOLUTION SPEC 800GB #EL1S

Specify GS2 (8U) Solution with 800GB SSD and EXP24S SFF Gen2-bay Drawer.

  • Attributes provided: #EGSM Specify
  • Attributes required: None
  • For 7014-T42: (#EGSM)
    • Minimum required: 0
    • Maximum allowed: 999 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: Does not apply
(#EGSN) - GS2 SOLUTION SPEC 1.2TB #EL1S

Specify GS2 (8U) Solution with 10K 1.2TB HDD and EXP24S SFF Gen2-bay Drawer.

  • Attributes provided: #EGSN Specify
  • Attributes required: None
  • For 7014-T42: (#EGSN)
    • Minimum required: 0
    • Maximum allowed: 5 (Initial order maximum: 5)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#EGSP) - GS4 SOLUTION SPEC 400GB #EL1S

Specify GS4 (12U) Solution with 400GB SSD and EXP24S SFF Gen2-bay Drawer.

  • Attributes provided: #EGSP Specify
  • Attributes required: None
  • For 7014-T42: (#EGSP)
    • Minimum required: 0
    • Maximum allowed: 999 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: Does not apply
(#EGSQ) - GS4 SOLUTION SPEC 800GB #EL1S

Specify GS4 (12U) Solution with 800GB SSD and EXP24S SFF Gen2-bay Drawer.

  • Attributes provided: #EGSQ Specify
  • Attributes required: None
  • For 7014-T42: (#EGSQ)
    • Minimum required: 0
    • Maximum allowed: 999 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: Does not apply
(#EGSR) - GS4 SOLUTION SPEC 1.2TB #EL1S

Specify GS4 (12U) Solution with 10K 1.2TB HDD and EXP24S SFF Gen2-bay Drawer.

  • Attributes provided: #EGSR Specify
  • Attributes required: None
  • For 7014-T42: (#EGSR)
    • Minimum required: 0
    • Maximum allowed: 999 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: Does not apply
(#EGSS) - GS6 SOLUTION SPEC 1.2TB #EL1S

Specify GS6 (16U) Solution with 10K 1.2TB HDD and EXP24S SFF Gen2-bay Drawer.

  • Attributes provided: #EGSS Specify
  • Attributes required: None
  • For 7014-T42: (#EGSS)
    • Minimum required: 0
    • Maximum allowed: 999 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: Does not apply
(#EGTH) GL2 (12U) SOLUTION SPECIFY (WITH 7.2K HDD 8TB + DCS3700e)

Specify GL2 (12U) Solution with 7.2K HDD 8TB + DCS3700e

  • Attributes required: None
  • For 7014-T42: (#EGTH)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 3)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EGTJ) - GL4 (20U) SOLUTION SPECIFY (WITH 7.2K HDD 8TB + DCS3700e)

Specify GL4 (20U) Solution with 7.2K HDD 8TB + DCS3700e

  • Attributes required: None
  • For 7014-T42: (#EGTJ)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 2)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EGTK) - GL6 (28U) SOLUTION SPECIFY (WITH 7.2K HDD 8TB + DCS3700e)

Specify GL6 (28U) Solution with 7.2K HDD 8TB + DCS3700e

  • Attributes required: None
  • For 7014-T42: (#EGTK)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 1)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EGT4) - GL2 SOLUTION SPEC 6TB DCS370E

Specify GL2 (12U) Solution with 7.2k HDD 6TB + DCS3700e.

  • Attributes provided: #EGT4 Specify
  • Attributes required: None
  • For 7014-T42: (#EGT4)
    • Maximum allowed: (Initial order maximum: )
    • Initial Order/MES/Both/Supported: Initial
(#EGT5) - GL4 SOLUTION SPEC 6TB DCS370E

Specify GL4 (12U) Solution with 7.2k HDD 6TB + DCS3700e.

  • Attributes provided: #EGT5 Specify
  • Attributes required: None
  • For 7014-T42: (#EGT5)
    • Minimum required:
    • Maximum allowed: 999 (Initial order maximum: 1)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU:
    • Return parts MES:
(#EGT6) - GL6 SOLUTION SPEC 6TB DCS370E

Specify GL6 (12U) Solution with 7.2k HDD 6TB + DCS3700e.

  • Attributes provided: #EGT6 Specify
  • Attributes required: None
  • For 7014-T42: (#EGT6)
    • Minimum required:
    • Maximum allowed: 999 (Initial order maximum: 1)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU:
    • Return parts MES:
(#EHJ0) - Administrative Tracking

This feature is use to identify Solution selection for administrative purposes within manufacturing to facilitate processing.

  • Attributes provided: MANUFACTURING ROUTING INDICATOR FOR ADMINISTRATIVE TRACKING
  • Attributes required: None
  • For 7014-T42: (#EHJ0)
    • Minimum required:
    • Maximum allowed: (Initial order maximum: )
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU:
    • Return parts MES:
(#EHLA) - IBM Data Engine for Hadoop Solution Specify

This feature indicates that IBM Data Engine for Hadoop Solution is installed on the system.

  • Attributes provided: None
  • Attributes required: None
  • For 7014-T42: (#EHLA)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: RHEL 7.2 (le) or later
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#EHLS) - ESS Next Gen Flash solution specify

(No Longer Available as of March 25, 2017)

  • Attributes provided: None
  • Attributes required: None
  • For 7014-T42: (#EHLS)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: No
(#EHP1) - OpenPower HPC Specify Code

This feature indicates that OpenPower HPC is installed on the system.

  • Attributes required: None
  • For 7014-T42: (#EHP1)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES:
(#EPAA) - HVDC PDU - 90A 6xOutlet

Feature ships a high voltage dc (HVDC) Power Distribution Unit (PDU) with six customer-usable Rong Feng RF-203P outlets. Each outlet is rated at up to 10 amp and has its own circuit breaker. The PDU is most typically used for 380 volt configurations, but is rated for 240-380 volt. The PDU is rated for 90 amps. The PDU comes with a permanently attached 4.3 m (14 ft) line cord which is un-terminated (no plug) which must be directly wired into a HVDC power source.

The PDU can be either vertically mounted in rack side pockets or horizontally mounted. Using the feature #EBA5 mounting specify communicates to IBM manufacturing it should be horizontally mounted. If horizontally mounted, the PDU uses 1U rack space and makes accessing power cords much easier.

Use HVDC power cords ordered with the server or I/O drawer to plug into the PDU RF-203P outlets. See HVDC power cord features #EPAD or #EPAC.

If ordering this PDU with a 7014-T00 or 7014-T42 rack which is being shipped from IBM at the same time, see PDU feature #EPAF (HVDC PDU - 90A 6xOutlet Alternate Base).

Limitation:

  • Not supported in North America
  • IBM Manufacturing does not factory integrate AC and DC PDUs in the same rack
  • Customers mixing AC and DC in the same rack must carefully follow power wiring guidelines
  • Attributes provided: HVDC PDU
  • Attributes required: HVDC power supplies and power cords on the server or I/O drawer
  • For 7014-T42: (#EPAA)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required: None.
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EPAF) - HVDC PDU - 90A 6xOutlet Alternate Base

Feature ships a high voltage dc (HVDC) Power Distribution Unit (PDU) with six customer-usable Rong Feng RF-203P outlets. See feature #EPAA for PDU technical information.

One feature #EPAF is optionally used in place of the one no-charge "base" #9188 feature code typically included with a 7014-T00 or 7014-T42 rack. Feature #EPAF and #EPAA are identical physically, but #EPAF has a lower price. One feature #EPAF can only be ordered with a 7014-T00 or T42 rack when the rack is initially shipped from IBM Manufacturing.

Limitation:

  • Not supported in North America
  • IBM Manufacturing does not factory integrate AC and DC PDUs in the same rack
  • Customers mixing AC and DC in the same rack must carefully follow power wiring guidelines
  • Attributes provided: HVDC PDU
  • Attributes required: new 7014 rack, HVDC power supplies and power cords on the server or I/O drawer
  • For 7014-T42: (#EPAF)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#EPAG) Power Distribution Unit (US) - 1 EIA Unit, Universal, Fixed Power Cord

This AC power distribution unit provides six C19 power outlets. Fixed power cord (IEC309 60A plug (3P+G). This PDU requires 3-phase electrical service.

  • Attributes provided: Six C19 power outlets
  • Attributes required: None
  • For 7014-T42: (#EPAG)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None.
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#EPTG) - High Function 9xC19 PDU

Switched, Monitoring (option with new 7014)

This is an intelligent, switched 200-240 volt AC Power Distribution Unit (PDU) with nine C19 receptacles on the front of the PDU. The PDU is mounted on the rear of the rack making the nine C19 receptacles easily accessible. Each receptacle has a 20 amp circuit breaker. Depending on country wiring standards the PDU is single-phase or three-phase wye. See three-phase #EPTK/EPTL for countries which do not use wye wiring.

The PDU can be mounted vertically in rack side pockets or it can be mounted horizontally. If mounted horizontally, it uses 1 EIA (1U) of rack space. See feature #EPTH for horizontal mounting hardware.

Device power cords with a C20 plug connect to C19 PDU receptacles and are ordered separately. One country-specific wall line cord is also ordered separately and attaches to a UTG524-7 connector on the front of the PDU. Supported line cords include features #6489, #6491, #6492, #6653, #6654, #6655, #6656, #6657, #6658, and #6667.

Two RJ45 ports on the front of the PDU enable the client to monitor each receptacle's electrical power usage and to remotely switch any receptacle on or off. The PDU is shipped with a generic PDU password and IBM strongly urges clients to change it upon installation.

There are also three C13 receptacles on the rear of the PDU positioned toward the middle of the rack. These are generally not easily accessed and therefore IBM does not generally recommend their use.

#EPTG and #EPTJ are identical PDUs. Up to one lower price #EPTG can be ordered with a new 7014-T42/T00 rack in place of a no-charge #9188 PDU.

For comparison, this is most similar to the earlier generation #7189 PDU

  • Attributes provided: Nine C19 PDU - switched, power monitoring
  • Attributes required: PDU wall line cord & space in 19-inch rack, new 7014 rack
  • For 7014-T42: (#EPTG)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: No
(#EPTH) - Horizontal PDU Mounting Hardware

This feature ships the hardware required to properly horizontally mount one #EPTG/EPTJ, #EPTK/EPTL, #EPTM/EPTN or #EPTP/EPTQ PDU in a 1U 19-inch rack. A 1U blank panel for the front of the rack for air-flow control is included.

Without this hardware, the PDU can be mounted vertically in the rack's side pockets, but can only be poorly mounted horizontally. The front end of the PDU will be firmly attached to the rear of the rack. But the front of the PDU will be unsupported toward the middle of the rack. Without this hardware, the unsupported end of the PDU will rest on the hardware mounted immediately below it. If that underlying hardware is removed from the rack there is no support for the PDU. Important Note: This feature code is typically used for an MES order and not for an original order of a new rack with #EPTn PDUs. As part of factory integration, IBM Manufacturing automatically adds this hardware without a feature code and at no additional charge when its #EPTn PDU placement logic calls for horizontally mounted PDUs. Use this feature code when (1) converting an existing vertically mounted #EPTn PDU to horizontal mounting or (2) separately ordering a #EPTn PDU for horizontal field installation.

  • Attributes provided: mounting hardware
  • Attributes required: High Function PDU (#EPT*) and space in 19-inch rack
  • For 7014-T42: (#EPTH)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 0)
    • OS level required: None
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes
    • Return parts MES: No
(#EPTJ) - High Function 9xC19 PDU

Switched, Monitoring

This is an intelligent, switched 200-240 volt AC Power Distribution Unit (PDU) with nine C19 receptacles on the front of the PDU. The PDU is mounted on the rear of the rack making the nine C19 receptacles easily accessible. Each receptacle has a 20 amp circuit breaker. Depending on country wiring standards the PDU is single-phase or three-phase wye. See three-phase #EPTK/EPTL for countries which do not use wye wiring.

The PDU can be mounted vertically in rack side pockets or it can be mounted horizontally. If mounted horizontally, it uses 1 EIA (1U) of rack space. See feature #EPTH for horizontal mounting hardware.

Device power cords with a C20 plug connect to C19 PDU receptacles and are ordered separately. One country-specific wall line cord is also ordered separately and attaches to a UTG524-7 connector on the front of the PDU. Supported line cords include features #6489, #6491, #6492, #6653, #6654, #6655, #6656, #6657, #6658, and #6667.

Two RJ45 ports on the front of the PDU enable the client to monitor each receptacle's electrical power usage and to remotely switch any receptacle on or off. The PDU is shipped with a generic PDU password and IBM strongly urges clients to change it upon installation.

There are also three C13 receptacles on the rear of the PDU positioned toward the middle of the rack. These are generally not easily accessed and therefore IBM does not generally recommend their use.

#EPTG and #EPTJ are identical PDUs. Up to one lower price #EPTG can be ordered with a new 7014-T42/T00 rack in place of a no-charge #9188 PDU.

For comparison, this is most similar to the earlier generation #7189 PDU

  • Attributes provided: Nine C19 PDU - switched, power monitoring
  • Attributes required: PDU wall line cord & space in 19-inch rack
  • For 7014-T42: (#EPTJ)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EPTK) - High Function 9xC19 PDU 3-Phase

Switched, Monitoring (option with new 7014)

This is an intelligent, switched 208 volt 3-phase AC Power Distribution Unit (PDU) with nine C19 receptacles on the front of the PDU. The PDU is mounted on the rear of the rack making the nine C19 receptacles easily accessible. Each receptacle has a 20 amp circuit breaker.

The PDU can be mounted vertically in rack side pockets or it can be mounted horizontally. If mounted horizontally, it uses 1 EIA (1U) of rack space. See feature #EPTH for horizontal mounting hardware.

Device power cords with a C20 plug connect to C19 PDU receptacles and are ordered separately. One wall line cord is provided with the PDU (no separate feature code) and has a IEC60309 60A plug (3P+G). The PDU supports up to 48 amps.

Two RJ45 ports on the front of the PDU enable the client to monitor each receptacle's electrical power usage and to remotely switch any receptacle on or off. The PDU is shipped with a generic PDU password and IBM strongly urges clients to change it upon installation.

There are also three C13 receptacles on the rear of the PDU positioned toward the middle of the rack. These are generally not easily accessed and therefore IBM does not generally recommend their use.

#EPTK and #EPTL are identical PDUs. Up to one lower price #EPTK can be ordered with a new 7014-T42/T00 rack in place of a no-charge #9188 PDU.

For comparison, this is most similar to the earlier generation #7196 PDU

  • Attributes provided: Nine C19 PDU - switched, power monitoring
  • Attributes required: Space in 19-inch rack, 3-phase 208V delta electrical service
  • For 7014-T42: (#EPTK)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: No
(#EPTL) - High Function 9xC19 PDU 3-Phase

Switched, Monitoring

This is an intelligent, switched 208 volt 3-phase AC Power Distribution Unit (PDU) with nine C19 receptacles on the front of the PDU. The PDU is mounted on the rear of the rack making the nine C19 receptacles easily accessible. Each receptacle has a 20 amp circuit breaker.

The PDU can be mounted vertically in rack side pockets or it can be mounted horizontally. If mounted horizontally, it uses 1 EIA (1U) of rack space. See feature #EPTH for horizontal mounting hardware.

Device power cords with a C20 plug connect to C19 PDU receptacles and are ordered separately. One wall line cord is provided with the PDU (no separate feature code) and has a IEC60309 60A plug (3P+G). The PDU supports up to 48 amps.

Two RJ45 ports on the front of the PDU enable the client to monitor each receptacle's electrical power usage and to remotely switch any receptacle on or off. The PDU is shipped with a generic PDU password and IBM strongly urges clients to change it upon installation.

There are also three C13 receptacles on the rear of the PDU positioned toward the middle of the rack. These are generally not easily accessed and therefore IBM does not generally recommend their use.

#EPTK and #EPTL are identical PDUs. Up to one lower price #EPTK can be ordered with a new 7014-T42/T00 rack in place of a no-charge #9188 PDU.

For comparison, this is most similar to the earlier generation #7196 PDU

  • Attributes provided: Nine C19 PDU - switched, power monitoring
  • Attributes required: space in rack, 3-phase 208V AC delta electrical service
  • For 7014-T42: (#EPTL)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EPTM) - High Function 12xC13 PDU

Switched, Monitoring (option with new 7014)

This is an intelligent, switched 200-240 volt AC Power Distribution Unit (PDU) with twelve C13 receptacles on the front of the PDU. The PDU is mounted on the rear of the rack making the twelve C13 receptacles easily accessible. Each receptacle has a 20 amp circuit breaker. Depending on country wiring standards the PDU is single-phase or three-phase wye. See three-phase #EPTK/EPTL for countries which do not use wye wiring.

The PDU can be mounted vertically in rack side pockets or it can be mounted horizontally. If mounted horizontally, it uses 1 EIA (1U) of rack space. See feature #EPTH for horizontal mounting hardware.

Device power cords with a C14 plug connect to C13 PDU receptacles and are ordered separately. One country-specific wall line cord is also ordered separately and attaches to a UTG524-7 connector on the front of the PDU. Supported line cords include features #6489, #6491, #6492, #6653, #6654, #6655, #6656, #6657, #6658, and #6667.

Two RJ45 ports on the front of the PDU enable the client to monitor each receptacle's electrical power usage and to remotely switch any receptacle on or off. The PDU is shipped with a generic PDU password and IBM strongly urges clients to change it upon installation.

#EPTM and #EPTN are identical PDUs. Up to one lower price #EPTM can be ordered with a new 7014-T42/T00 rack in place of a no-charge #9188 PDU.

For comparison, this is most similar to the earlier generation #7109 PDU

  • Attributes provided: Twelve C13 PDU - switched, power monitoring
  • Attributes required: PDU wall line cord & space in 19-inch rack
  • For 7014-T42: (#EPTM)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: No
(#EPTN) - High Function 12xC13 PDU

Switched, Monitoring

This is an intelligent, switched 200-240 volt AC Power Distribution Unit (PDU) with twelve C13 receptacles on the front of the PDU. The PDU is mounted on the rear of the rack making the twelve C13 receptacles easily accessible. Each receptacle has a 20 amp circuit breaker. Depending on country wiring standards the PDU is single-phase or three-phase wye. See three-phase #EPTK/EPTL for countries which do not use wye wiring.

The PDU can be mounted vertically in rack side pockets or it can be mounted horizontally. If mounted horizontally, it uses 1 EIA (1U) of rack space. See feature #EPTH for horizontal mounting hardware.

Device power cords with a C14 plug connect to C13 PDU receptacles and are ordered separately. One country-specific wall line cord is also ordered separately and attaches to a UTG524-7 connector on the front of the PDU. Supported line cords include features #6489, #6491, #6492, #6653, #6654, #6655, #6656, #6657, #6658, and #6667.

Two RJ45 ports on the front of the PDU enable the client to monitor each receptacle's electrical power usage and to remotely switch any receptacle on or off. The PDU is shipped with a generic PDU password and IBM strongly urges clients to change it upon installation.

#EPTM and #EPTN are identical PDUs. Up to one lower price #EPTM can be ordered with a new 7014-T42/T00 rack in place of a no-charge #9188 PDU.

For comparison, this is most similar to the earlier generation #7109 PDU

  • Attributes provided: Twelve C13 PDU - switched, power monitoring
  • Attributes required: PDU wall line cord & space in 19-inch rack
  • For 7014-T42: (#EPTN)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EPTP) - High Function 12xC13 PDU 3-Phase

Switched, Monitoring (option with new 7014)

This is an intelligent, switched 208 volt 3-phase AC Power Distribution Unit (PDU) with twelve C13 receptacles on the front of the PDU. The PDU is mounted on the rear of the rack making the twelve C13 receptacles easily accessible. Each receptacle has a 20 amp circuit breaker.

The PDU can be mounted vertically in rack side pockets or it can be mounted horizontally. If mounted horizontally, it uses 1 EIA (1U) of rack space. See feature #EPTH for horizontal mounting hardware.

Device power cords with a C14 plug connect to C13 PDU receptacles and are ordered separately. One wall line cord is provided with the PDU (no separate feature code) and has a IEC60309 60A plug (3P+G). The PDU supports up to 48 amps.

Two RJ45 ports on the front of the PDU enable the client to monitor each receptacle's electrical power usage and to remotely switch any receptacle on or off. The PDU is shipped with a generic PDU password and IBM strongly urges clients to change it upon installation.

#EPTP and #EPTQ are identical PDUs. Up to one lower price #EPTP can be ordered with a new 7014-T42/T00 rack in place of a no-charge #9188 PDU.

For comparison, this is most similar to the earlier generation #7196 PDU, but offers C13 receptacles

  • Attributes provided: Twelve C13 PDU - switched, power monitoring
  • Attributes required: Space in 19-inch rack, 3-phase 208V delta electrical service
  • For 7014-T42: (#EPTP)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: No
(#EPTQ) - High Function 12xC13 PDU 3-Phase

Switched, Monitoring

This is an intelligent, switched 208 volt 3-phase AC Power Distribution Unit (PDU) with twelve C13 receptacles on the front of the PDU. The PDU is mounted on the rear of the rack making the twelve C13 receptacles easily accessible. Each receptacle has a 20 amp circuit breaker.

The PDU can be mounted vertically in rack side pockets or it can be mounted horizontally. If mounted horizontally, it uses 1 EIA (1U) of rack space. See feature #EPTH for horizontal mounting hardware.

Device power cords with a C14 plug connect to C13 PDU receptacles and are ordered separately. One wall line cord is provided with the PDU (no separate feature code) and has a IEC60309 60A plug (3P+G). The PDU supports up to 48 amps.

Two RJ45 ports on the front of the PDU enable the client to monitor each receptacle's electrical power usage and to remotely switch any receptacle on or off. The PDU is shipped with a generic PDU password and IBM strongly urges clients to change it upon installation.

#EPTP and #EPTQ are identical PDUs. Up to one lower price #EPTP can be ordered with a new 7014-T42/T00 rack in place of a no-charge #9188 PDU.

For comparison, this is most similar to the earlier generation #7196 PDU, but offers C13 receptacles

  • Attributes provided: Twelve C13 PDU - switched, power monitoring
  • Attributes required: space in rack, 3-phase 208V AC delta electrical service
  • For 7014-T42: (#EPTQ)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#ERGB) - Acoustic Front Black Door

Acoustic front black door. This door hinges on the left side. ("Left" is as you face the door from the outside of the rack).

  • Attributes provided: Acoustic door
  • Attributes required: 7014-T42 with one or more 9119-MHE/MME servers
  • For 7014-T42: (#ERGB)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#ERGC) - Ruggedized Rack Feature, Extra Strength

For enhanced rigidity and stability of the rack, the optional Ruggedized Rack Feature provides additional hardware that reinforces the rack and enables anchoring to the floor. This hardware is designed primarily for use in locations where earthquakes are a concern. The feature includes a large steel brace or truss that bolts into the front and rear of the rack. Each brace is hinged on the left side so it can swing out of the way for easy access to the rack drawers when necessary. The Ruggedized Rack Feature also includes hardware for bolting the rack to a concrete floor or a similar surface, and bolt-in steel filler panels for any unoccupied spaces in the rack when shipped from IBM Manufacturing.

This #ERGC Ruggedized Rack feature is similar to the #6080 Ruggedized Rack feature except stronger bracing is used. #ERGC supports at least 40% more weight per EIA and has been tested to AC-156 and NEBS Zone-4 standards. #ERGC should be used for heavier servers such as the Power E870/E880 versus #6080.

Limitations:

  • This feature is plant orderable only and can not be added as an MES order. A slightly different welding on the 7014-T42 frame is used to attach the bracing which is only available in the plant.
  • Due the placement of #ERGC bracing connection points, the only supported rack door for this rack is #ERGD. Front trim kits are also not supported.
  • The 8-inch rear expansion feature ERG0 is not supported.
  • Attributes provided: Extra structural bracing, bolt downs, and steel filler panels
  • Attributes required: 7014-T42 rack and #ERGD doors
  • For 7014-T42: (#ERGC)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: No
(#ERGD) - Rack Doors for 2M Ruggedized Rack

7014-T42 2 meter rack door option to be used the Ruggedized Rack feature #ERGC. This provides both a front and rear door which are identical to each other and are 110mm (4.3") deep per door. Although the doors are not acoustic, they provide aesthetically pleasing coverage over the bracing from #ERGC. This door hinges on the left side. ("Left" is as you face the door from the outside of the rack).

  • Attributes provided: Doors for use with #ERGC ruggedized rack feature
  • Attributes required: 7014-T42 rack with #ERGC ruggedized rack feature
  • For 7014-T42: (#ERGD)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: No
(#ERLR) - Left/Right PDU Redundancy

This specify code will force an even number of PDUs onto the configuration and will alert Manufacturing to plug the PDU equipment in a left/right pattern. The L/R specify will be defaulted on all enterprise racks being configured. Default can be overriden during the configuration session.

  • Attributes provided: PDU Redundancy
  • Attributes required: Rack
  • For 7014-T42: (#ERLR)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Yes
    • Return parts MES: No
(#ER00) - Custom Soln Center Services per PRPQ 8A2064

Routes system to the IBM Rochester Custom Solution Center for special services. Through PRPQ 8A2064 Customer is able to specify Ethernet Network and System cabling design. Customer is also able to provide input for manufacturing test. Other available services include customer ability to specify physical location of the systems, I/O drawers, IBM Ethernet Rack Switches and attached expansion drawers in the rack. Custom software and configuration of customer software per customer specification is available. The customer's input is collected and verified via i-Listed PRPQ 8A2064. Product safety rules must be met concerning weight distribution for shipping which may affect racking specification.

Final approval will be provided by the IBM Rochester Custom Solution Center via i-Listed PRPQ 8A2064.

  • For 7014-T42: (#ER00)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: Does not apply
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ER02) - Rack Content Specify: 8408-E8D

Indicator or rack space utilization (5 EIA units)

  • Attributes provided: Indicator or rack space utilization
  • Attributes required: 5U of rack space
  • For 7014-T42: (#ER02)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 8)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Yes
    • Return parts MES:
(#ER03) - Rack Content Specify: 2076-224 - 2U

Indicator or rack space utilization

  • Attributes provided: Indicator or rack space utilization
  • Attributes required: 2U of rack space
  • For 7014-T42: (#ER03)
    • Minimum required: 0
    • Maximum allowed: 21 (Initial order maximum: 21)
    • OS level required: Does not apply
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ER04) - Rack Content Specify: 2076-124 - 2U

Indicator or rack space utilization

  • Attributes provided: Indicator or rack space utilization
  • Attributes required: 2U of rack space
  • For 7014-T42: (#ER04)
    • Minimum required: 0
    • Maximum allowed: 21 (Initial order maximum: 21)
    • OS level required: Does not apply
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ER07) - Rack Content Specify: 1611-16E 1EIA (BINGO)

Indicator or rack space utilization

  • Attributes provided: Indicator or rack space utilization
  • For 7014-T42: (#ER07)
    • Minimum required: 0
    • Maximum allowed: 6 (Initial order maximum: 6)
    • OS level required: Does not apply
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ER08) - Rack Content Specify: 1455-24E/7120-24E

Indicator or rack space utilization

  • Attributes provided: Indicator or rack space utilization
  • For 7014-T42: (#ER08)
    • Minimum required: 0
    • Maximum allowed: 6 (Initial order maximum: 6)
    • OS level required: Does not apply
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ER09) - Rack Content Specify: 1455-48E

Indicator or rack space utilization

  • Attributes provided: Indicator or rack space utilization
  • For 7014-T42: (#ER09)
    • Minimum required: 0
    • Maximum allowed: 6 (Initial order maximum: 6)
    • OS level required: Does not apply
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ER0A) - Rack Content Specify: 1455-64C

Indicator or rack space utilization

  • Attributes provided: Indicator or rack space utilization
  • For 7014-T42: (#ER0A)
    • Minimum required: 0
    • Maximum allowed: 6 (Initial order maximum: 6)
    • OS level required: Does not apply
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ER0B) - Rack Content Specify: 1455-48T

Indicator for rack space utilization

  • Attributes provided: Indicator for rack space utilization
  • For 7014-T42: (#ER0B)
    • Minimum required: 0
    • Maximum allowed: 36 (Initial order maximum: 36)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Yes
    • Return parts MES: No
(#ER0C) - Rack Content Specify: 1455-64F

Indicator for rack space utilization

  • Attributes provided: Indicator for rack space utilization
  • For 7014-T42: (#ER0C)
    • Minimum required: 0
    • Maximum allowed: 42 (Initial order maximum: 42)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Yes
    • Return parts MES: No
(#ER0D) - Rack Content Specify: 9109-RMD

Indicator or rack space utilization (5 EIA units)

  • Attributes provided: Indicator or rack space utilization
  • Attributes required: 5U of rack space
  • For 7014-T42: (#ER0D)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 8)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Initial
    • CSU: Yes
    • Return parts MES:
(#ER0E) - Rack Content Specify: 7316-TF4 -- 1 EIA

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: 1U (EIA) of rack space
  • For 7014-T42: (#ER0E)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ER0H) - Rack Content Specify: 8248-L4T

(No Longer Available as of November 30, 2015)

Indicator or rack space utilization (5 EIA units)

  • Attributes provided: Indicator or rack space utilization
  • Attributes required: 5U of rack space
  • For 7014-T42: (#ER0H)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 8)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ER0J) - Rack Content Specify: 8412-EAD

(No Longer Available as of November 30, 2015)

Indicator or rack space utilization (4 EIA units).

  • Attributes provided: Indicator or rack space utilization
  • Attributes required: 4U of rack space
  • For 7014-T42: (#ER0J)
    • Minimum required: 0
    • Maximum allowed: 10 (Initial order maximum: 10)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ER0M) - Rack Content Specify for #EMX0 I/O Expansion Drawer

Allocates 4EIA unit space in Rack for the I/O Expansion Drawer (#EMX0).

  • Attributes provided: Indicator or rack space utilization
  • Attributes required: 4U of rack space
  • For 7014-T42: (#ER0M)
    • Minimum required: 0
    • Maximum allowed: 9 (Initial order maximum: 9)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ER0T) - Rack Content Specify 8286-41A/42A - 4EIA

Indicator of rack space utilization

  • Attributes provided: Indicator of 4EIA rack space utilization
  • Attributes required: None
  • For 7014-T42: (#ER0T)
    • Minimum required: 0
    • Maximum allowed: 10 (Initial order maximum: 10)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ER0U) - Rack Content Specify: 8284-22A - 2EIA

Indicator of rack space utilization

  • Attributes provided: Indicator of 2EIA rack space utilization
  • Attributes required: None
  • For 7014-T42: (#ER0U)
    • Minimum required: 0
    • Maximum allowed: 21 (Initial order maximum: 21)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ER0V) - Rack Content Specify: 8247/5148-22L - 2EIA

Indicator of rack space utilization

  • Attributes provided: Indicator of 2EIA rack space utilization
  • Attributes required: None
  • For 7014-T42: (#ER0V)
    • Minimum required: 0
    • Maximum allowed: 21 (Initial order maximum: 21)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ER0Y) - Rack Content Specify: 8412-EAD

Indicator or rack space utilization

  • Attributes provided: Indicator or rack space utilization
  • Attributes required: 8U of rack space
  • For 7014-T42: (#ER0Y)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ER0Z) - Rack Content Specify: 8247-42L - 4EIA

Indicator of rack space utilization

  • Attributes provided: Indicator of 2EIA rack space utilization
  • Attributes required: None
  • For 7014-T42: (#ER0Z)
    • Minimum required: 0
    • Maximum allowed: 10 (Initial order maximum: 10)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ER10) Rack Content Specify first enclosure: 9119-MHE, 9119-MME - 7 EIA

Rack content specify for first enclosure - 7 EIA. Supports 9119-MHE and 9119-MME.

  • Attributes provided: Indicator or rack space utilization
  • Attributes required: None
  • For 7014-T42: (#ER10)
    • Minimum required: 0
    • Maximum allowed: 6 (Initial order maximum: 6)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ER11) Rack Content Specify second enclosure: 9119-MHE, 9119-MME - 12 EIA

Rack content specify for second enclosure - 12 EIA. Supports 9119-MHE and 9119-MME.

  • Attributes provided: Indicator or rack space utilization
  • Attributes required: None
  • For 7014-T42: (#ER11)
    • Minimum required: 0
    • Maximum allowed: 3 (Initial order maximum: 3)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ER12) Rack Content Specify third enclosure: 9119-MHE, 9119-MME - 17 EIA

Rack content specify for third enclosure - 17 EIA. Supports 9119-MHE and 9119-MME.

  • Attributes provided: Indicator or rack space utilization
  • Attributes required: None
  • For 7014-T42: (#ER12)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ER13) Rack Content Specify fourth enclosure: 9119-MHE, 9119-MME - 22 EIA

Rack content specify for fourth enclosure - 22 EIA. Supports 9119-MHE and 9119-MME.

  • Attributes provided: Indicator or rack space utilization
  • Attributes required: None
  • For 7014-T42: (#ER13)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ER14) Rack Content Specify 1U Horizontal PDU - 1 EIA

Indicator that reserve rack space for the 1U Horizontal PDU.

  • Attributes provided: Indicator or rack space utilization
  • Attributes required: None
  • For 7014-T42: (#ER14)
    • Minimum required: 0
    • Maximum allowed: 10 (Initial order maximum: 10)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ER15) Rack Content Specify reserve 1U rack space for PDU

Rack content indicator for PDU - Reserve 1U rack space - 1 EIA. Supports PDU.

  • Attributes provided: Indicator or rack space utilization
  • Attributes required: None
  • For 7014-T42: (#ER15)
    • Minimum required: 0
    • Maximum allowed: 12 (Initial order maximum: 12)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ER17) - Rack Content Specify: 8408-E8E

Indicator or rack space utilization

  • Attributes provided: Indicator or rack space utilization
  • Attributes required: 4U of rack space
  • For 7014-T42: (#ER17)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 8)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ER18) - Rack Content Specify: 5148/8247-21L - 2EIA

Indicator of rack space utilization

  • Attributes provided: Indicator of 2EIA rack space utilization
  • Attributes required: None
  • For 7014-T42: (#ER18)
    • Minimum required: 0
    • Maximum allowed: 21 (Initial order maximum: 21)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ER19) - RACK SPECIFY FC EMX0

Indicator that reserve adjacent 4EIA rack space for the I/O Expansion Drawer feature EMX0.

  • Attributes provided: Specify 4EIA space
  • Attributes required: Available 4EIA space in Rack
  • For 7014-T42: (#ER19)
    • Minimum required: 0
    • Maximum allowed: 4 (Initial order maximum: 4)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ER1B) Rack Content Specify: Reserve 1U Rack Space at Bottom of Rack

Indicator or rack space utilization

  • Attributes provided: Indicator or rack space utilization
  • For 7014-T42: (#ER1B)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: No
(#ER1D) - Rack Content Specify: 8831-NF2

Indicator for rack space utilization

  • Attributes provided: Indicator for rack space utilization
  • For 7014-T42: (#ER1D)
    • Minimum required: 0
    • Maximum allowed: 42 (Initial order maximum: 42)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: No
(#ER1F) - FlashSystem 9840/9843 - 2 E1A

Indicator for 2 EIA rack space utilization for FlashSystem Drawer

  • Attributes provided: Indicator or rack space utilization
  • For 7014-T42: (#ER1F)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 8)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: No
(#ER1H) - Rack Content Specify: 8831-F36

Indicator for rack space utilization

  • Attributes provided: Indicator for rack space utilization
  • For 7014-T42: (#ER1H)
    • Minimum required: 0
    • Maximum allowed: 4 (Initial order maximum: 4)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ER1L) - Rack Content Specify

8408-44E

Indicator or rack space utilization

  • Attributes provided: Indicator or rack space utilization
  • Attributes required: 4U of rack space
  • For 7014-T42: (#ER1L)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 8)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ER1P) - Rack Content Specify

(No Longer Available as of February 23, 2017)

8348-21C 2EIA

Indicator or rack space utilization

  • Attributes provided: Indicator or rack space utilization
  • Attributes required: None
  • For 7014-T42: (#ER1P)
    • Minimum required: 0
    • Maximum allowed: 20 (Initial order maximum: 20)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ER1T) Rack Content Specify: Reserve 1U Rack Space at Top of Rack

Indicator or rack space utilization

  • Attributes provided: Indicator or rack space utilization
  • For 7014-T42: (#ER1T)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: No
(#ER1U) - Rack content specify 5147-1F2 3EIA

(No Longer Available as of March 25, 2017)

  • Attributes required: None
  • For 7014-T42: (#ER1U)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 8)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: No
(#ER1V) - Rack Content Specify

8831-S52 1EIA

Rack Content Specify: 8831-S52 1EIA

Indicator for rack space utilization

  • Attributes provided: Indicator for rack space utilization
  • Attributes required: None
  • For 7014-T42: (#ER1V)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 8)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: No
(#ER24) - Rack Content Specify

8335-GCA 2EIA

Indicator or rack space utilization (2 EIA units)

  • For 7014-T42: (#ER24)
    • Minimum required: 0
    • Maximum allowed: 18 (Initial order maximum: 18)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ER25) - Rack Content Specify

(No Longer Available as of February 14, 2017)

8335-GTA 2EIA

Indicator or rack space utilization (2 EIA units)

  • For 7014-T42: (#ER25)
    • Minimum required: 0
    • Maximum allowed: 18 (Initial order maximum: 18)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ER26) - Rack Content Specify

8867-FM1/FM2 1EIA

Indicator or rack space utilization (1 EIA units)

  • For 7014-T42: (#ER26)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: No
(#ER28) - Rack Content Specify 8335 - GTB 2EIA

Indicator or rack space utilization (2 EIA units)

  • For 7014-T42: (#ER28)
    • Minimum required: 0
    • Maximum allowed: 18 (Initial order maximum: 1)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: No
(#ER29) - Rack Content Specify 5147-084 5EIA

Indicator or rack space utilization (5 EIA units)

  • For 7014-T42: (#ER29)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 1)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES:
(#ER2B) Rack Content Specify: Reserve 2U Rack Space at Bottom of Rack

Indicator or rack space utilization

  • Attributes provided: Indicator or rack space utilization
  • Attributes required: 2U of bottom rack space
  • For 7014-T42: (#ER2B)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ER30) - Rack Content Specify

8284-21A - 2EIA

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: None.
  • For 7014-T42: (#ER30)
    • Minimum required: 0
    • Maximum allowed: 21 (Initial order maximum: 21 )
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES:
(#ER2T) - Rack Content Specify: Reserve 2U Rack Space at Top of Rack

Indicator or rack space utilization

  • Attributes provided: Indicator or rack space utilization
  • Attributes required: 2U of top rack space
  • For 7014-T42: (#ER2T)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ERC0) - Rack Content Specify EXP12SX #ESLL/#ELLL 2-EIA/2U

Indicator of rack space utilization

  • Attributes provided: Indicator of rack space utilization
  • Attributes required: none
  • For 7014-T42: (#ERC0)
    • Minimum required: 0
    • Maximum allowed: 21 (Initial order maximum: 21)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ERC1) - Rack Content Specify EXP24SX #ESLS/#ELLS 2-EIA/2U

Indicator of rack space utilization

  • Attributes provided: Indicator of rack space utilization
  • Attributes required: none
  • For 7014-T42: (#ERC1)
    • Minimum required: 0
    • Maximum allowed: 21 (Initial order maximum: 21)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ERC2) - Rack Content Specify 7063-CR1

Indicator of rack space utilization.

  • Attributes provided: Indicator of rack space utilization
  • Attributes required: None
  • For 7014-T42: (#ERC2)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ERG0) - Rack Rear Extension

Extends the rear of a 2.0M enterprise rack (7014-T42) eigth inches or 20.3 cm. The extra depth provides extra space for cable management helping to keep the center of the rack more open for airflow and access to the rear of the equipment mounted in the rack. This rear extension does not increase or decrease the rack's 42 EIA (42U) vertical size. The extension does increase the floor footprint.

  • Attributes provided: Rack rear expansion.
  • Attributes required: None
  • For 7014-T42: (#ERG0)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

    Note: Cannot be used with #ERGC ruggedized rack feature or its #ERGD door.

(#ERG7) - Front Door for Power 770 & 780 2.0 Meter Rack (High Perforation)

This feature provides an attractive black full height rack door. The door is steel, with a perforated flat front surface. The perforation pattern extends from the bottom to the top of the door to enhance ventilation and provide some visibility into the rack. This door hinges on the left side. ("Left" is as you face the door from the outside of the rack).

  • Attributes provided: Front door
  • Attributes required: None
  • For 7014-T42: (#ERG7)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#ESC0) - S&H - No Charge

No charge shipping and handling.

  • Attributes provided: None
  • Attributes required: Sales Preapproval Required
  • For 7014-T42: (#ESC0)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: Does not apply
(#ESC1) - Rack S&H-a
  • For 7014-T42: (#ESC1)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: No
(#ESS0) - ESS Seagate Solution Specify

ESS SEAGATE Solution Specify ESS Seagate Solution Specify.

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: None.
  • For 7014-T42: (#ESS0)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1 )
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ESS1) - ESS GL2S Solution Specify (4TB HDD) - 664 TB Raw Disk Capacity

This feature indicates this is an GL2S Solution Specify (4TB HDD).

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: None.
  • For 7014-T42: (#ESS1) o Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2 )
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ESS2) - ESS GL2S Solution Specify (8TB HDD) - 1328 TB Raw Disk Capacity

This feature indicates this is an GL2S Solution Specify (8TB HDD).

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: None.
  • For 7014-T42: (#ESS2)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2 )
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ESS3) - ESS GL2S Solution Specify (10TB HDD) - 1660 TB Raw Disk Capacity

This feature indicates this is an GL2S Solution Specify (10TB HDD).

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: None.
  • For 7014-T42: (#ESS3)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2 )
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ESS4) - ESS GL4S Solution Specify (4TB HDD) - 1336 TB Raw Disk Capacity

This feature indicates this is an GL4S Solution Specify (4TB HDD).

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: None.
  • For 7014-T42: (#ESS4)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1 )
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ESS5) - ESS GL4S Solution Specify (8TB HDD) - 2672 TB Raw Disk Capacity

This feature indicates this is an GL4S Solution Specify (8TB HDD).

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: None.
  • For 7014-T42: (#ESS5)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1 )
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ESS6) - ESS GL4S Solution Specify (10TB HDD) - 3340 TB Raw Disk Capacity

This feature indicates this is an GL4S Solution Specify (10TB HDD).

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: None.
  • For 7014-T42: (#ESS6)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1 )
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ESS7) - ESS GL6S Solution Specify (4TB HDD) - 2008 TB Raw Disk Capacity

This feature indicates this is an GL6S Solution Specify (4TB HDD).

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: None.
  • For 7014-T42: (#ESS7)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1 )
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ESS8) - ESS GL6S Solution Specify (8TB HDD) - 4016 TB Raw Disk Capacity

This feature indicates this is an GL6S Solution Specify (8TB HDD).

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: None.
  • For 7014-T42: (#ESS8)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1 )
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ESS9) - ESS GL6S Solution Specify (10TB HDD) - 5020 TB Raw Disk Capacity

This feature indicates this is an GL6S Solution Specify (10TB HDD).

  • Attributes provided: Indicator of rack space utilization.
  • Attributes required: None.
  • For 7014-T42: (#ESS9)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1 )
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ESSC) - ESS 2U24 STORAGE SOLUTION SPECIFY

This feature indicates ESS 2U24 STORAGE SOLUTION SPECIFY

  • For 7014-T42: (#ESSC)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES:
(#ESSD) - ESS GS1S Solution Specify (3.84TB SSD) - 92 TB Raw Disk Capacity

This feature indicates ESS GS1S SOLUTION SPECIFY (94TB)

  • For 7014-T42: (#ESSD)
    • Minimum required: 0
    • Maximum allowed: 6 (Initial order maximum: 6)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES:
(#ESSE) - ESS GS1S SOLUTION SPECIFY (15.36TB SSD) - 368 TB Raw Disk Capacity

This feature indicates ESS GS1S SOLUTION SPECIFY (360TB)

  • For 7014-T42: (#ESSE)
    • Minimum required: 0
    • Maximum allowed: 6 (Initial order maximum: 6)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES:
(#ESSF) - ESS GS2S SOLUTION SPECIFY (3.84TB SSD) - 184 TB Raw Disk Capacity

This feature indicates ESS GS2S SOLUTION SPECIFY (188TB)

  • For 7014-T42: (#ESSF)
    • Minimum required: 0
    • Maximum allowed: 5 (Initial order maximum: 5)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES:
(#ESSG) - ESS GS2S SOLUTION SPECIFY (15.36TB SSD) - 737 TB Raw Disk Capacity

This feature indicates ESS GS2S SOLUTION SPECIFY (720TB)

  • For 7014-T42: (#ESSG)
    • Minimum required: 0
    • Maximum allowed: 5 (Initial order maximum: 5)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES:
(#ESSK) - ESS GS4S SOLUTION SPECIFY (3.84TB SSD) - 368 TB Raw Disk Capacity

This feature indicates ESS GS4S SOLUTION SPECIFY (376TB)

  • For 7014-T42: (#ESSK)
    • Minimum required: 0
    • Maximum allowed: 3 (Initial order maximum: 3)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES:
(#ESSL) - ESS GS4S SOLUTION SPECIFY (15.36TB SSD) - 1474 TB Raw Disk Capacity

This feature indicates ESS GS4S SOLUTION SPECIFY (1440TB)

  • For 7014-T42: (#ESSL)
    • Minimum required: 0
    • Maximum allowed: 3 (Initial order maximum: 3)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES:

Back to topBack to top
 
Accessories

None.

Customer replacement parts

None.
Back to topBack to top
 

Machine elements

None.
Back to topBack to top
 

Supplies

None.