IBM Scale Out Network Attached Storage
IBM United States Hardware Announcement 110-037February 9, 2010
| Table of contents | Document options | ||||||||||||||||||||
|
|
(Corrected on March 3, 2010)
The At a glance and Description sections have been updated|
|
| At a glance |
The IBM® Scale Out Network Attached Storage (SONAS) is a highly scalable system designed to provide a clustered NAS system with a single name space for CIFS, NFS, and FTP services. The system consists of two to thirty Interface nodes (2851-SI1), one to thirty storage pods consisting of the Storage node (2851-SS1), Storage controller (2851-DR1) and attached disks, and one to two Management nodes (2851-SM1). The maximum configuration provides up to 14.4 PB of storage capacity in a single clustered, highly-redundant system.
The storage used in the SONAS system can be high performance 15K RPM SAS hard disk drives or high capacity 7.2K RPM SATA hard disk drives, allowing users to tune the configuration to suit their needs.
There are three rack configurations (2851-RXA, -RXB, and -RXC) that can be populated with the systems and switches needed to configure according to the needs of the user environment.
For ordering, contact your IBM representative, an IBM Business Partner, or IBM Americas Call Centers at 800-IBM-CALL (Reference: SE001).
|
|
| Overview |
IBM Scale Out Network Attached Storage (SONAS) is a Scale Out NAS offering designed to manage vast repositories of information in enterprise environments requiring very large capacities, high levels of performance, and high availability. The system supports multiple petabytes of storage and up to a billion files in a single file system and supports up to 256 file systems per system. Data access to the system from client computers is provided using industry standard network file protocols NFS v2/v3, CIFS, and FTP (including z/OS® NFS client support). In addition, the system supports traditional NAS features and functions, including:
- Snapshots
- Quotas (user, group, and fileset level)
- Integration with user directory servers such as Microsoft® Active Directory (AD) and Lightweight Directory Access Protocol (LDAP)
- Command line interface (CLI) and browser-based graphical user interface (GUI)
- Call home and remote support capabilities
In addition to these traditional features, the system supports advanced features, including integrated Tivoli® Storage Manager (TSM) backup client.
The system consists of:
- Management node
- Interface nodes
- Storage nodes
- Storage controllers
- Disk storage expansion units
- Ethernet and InfiniBand switches and racks
The Management node provides a central point for the system administrator to configure, monitor, and manage the system. The management node supports both a browser-based graphical user interface (GUI) and a command line interface (CLI). It also provides a System Health Center for monitoring the overall health of the system.
The Interface node provides the network port connection and the file services for the IBM SONAS system. These nodes can operate at up to 10 Gb speeds with optional adapters to providing extremely fast access to data. They are connected to the rest of the SONAS system via a redundant high speed InfiniBand data network.
The system has the concept of a storage pod. Each storage pod consists of a pair of storage nodes and one or two storage controllers. Each storage controller contains 60 disks, and can have one storage expansion attached for 60 additional disks per controller. Each storage pod supports a maximum of 240 hard disk drives. A maximum of 30 storage pods are supported for a maximum of 7200 hard disk drives in a single system.
These systems are configured within three pre-defined, customizable rack configurations. The Base Rack (2851-RXA) contains the management node, the InfiniBand switches, and from two to six interface nodes with up to one storage pod. Each Storage Expansion Rack (2851-RXB) contains up to two storage pods, for a maximum of 480 disks. The Interface Expansion Rack (2851-RXC) contains up to twenty additional interface nodes.
|
|
| Key prerequisites |
Orders for the IBM Scale Out Network Attached Storage (SONAS) models must be configured using the eConfigurator (ECMSSD) to support accurate and complete order entry.
|
|
| Planned availability date |
- March 12, 2010: IBM Scale Out Network Attached Storage (SONAS) new order shipment begins
- April 23, 2010:
- 2 TB drives for IBM Scale Out Network Attached Storage (Feature #1301) for SONAS nodes (2851-DR1, 2851-DE1)
- Acoustic doors (Feature #6249) for SONAS racks (2851-RXA, 2851-RXB and 2851-RXC)
- June 12, 2010: Rear door heat exchanger (Feature #6858) for SONAS racks (2851-RXA, 2851-RXB, 2851-RXC)
|
|
| Description |
The main components of the IBM Scale Out Network Attached Storage (SONAS) system are the Interface node (2851-SI1), Management node (2851-SM1), Storage node (2851-SS1), Storage controller (2851-DR1), and Disk Storage expansion Unit (2851-DE1). These components are assembled into one of three rack configurations with Ethernet and InfiniBand switches.
The minimum SONAS system configuration consists of:
- Two Interface nodes
- Two 36-port 4X DDR InfiniBand switches
- One Management node
- Two Storage nodes with one Storage controller
The maximum size of a SONAS system, in terms of Interface nodes and Storage pods, depends on whether the 36-port or 96-port InfiniBand switch is selected. Each of the following major components requires one IB port on each IB switch:
- Management node
- Interface node
- Storage node
Three InfiniBand ports of each IB switch are reserved for the following components:
- Two reserved for future use
- One for the required Management node
The remaining IB ports are available for Interface nodes and Storage nodes.
The Interface node (2851-SI1) is a 2U server containing the following:
- Two Intel® Xeon® E5530 (Nehalem EP) quad-core processors
- 32 GB of DDR3 memory standard, with feature to add an additional 32 GB of memory
- Four onboard 10/100/1000 Ethernet ports (two available for customer use)
- Two 300 GB 2.5-inch SFF 10K RPM SAS Slim-HS hard disk drives with mirroring between the two HDDs
- Four PCIe Gen 2.0 x8 adapter slots (two available for customer use)
- Integrated Baseboard Management controller (IBMC)
- Two redundant hot-swappable power supplies
- Six redundant hot-swappable cooling fans
The Interface node provides the connections to the customer's IP network for attaching to the SONAS system for network file serving capabilities (CIFS, NFS, FTP). A SONAS system contains a minimum of two Interface nodes and a maximum of 30.
The Interface node contains two redundant hot-swappable 300 GB 2.5-inch 10K RPM SAS HDDs with mirroring between them for high-availability. The HDDs contain the SONAS System Software product which hosts the operating system and all other software needed for an operational SONAS system.
Two of the PCIe adapter slots are already populated with two single-port 4X Double Data Rate (DDR) InfiniBand Host Channel Adapters (HCA). The two HCAs attach to two independent InfiniBand switches in the SONAS system and interconnect the Interface nodes to the Management node(s) and the Storage nodes.
Two of the PCIe adapter slots are available for customer use to add more adapters for host IP interface connectivity.
Each Interface node comes standard with two 10/100/1000 Ethernet ports available to connect to the customer's IP network. Additional Ethernet connectivity may be achieved by adding one of the following features:
- 1100 (Quad-port 1GbE NIC)
- 1101 (Dual-port 10 Gb Converged Network Adapter).
Each Interface node is connected to the two InfiniBand switches by one InfiniBand cable to each switch, a total of two cables. The InfiniBand Host Channel Adapters (HCA) in the Interface nodes have an X4 port. The 36-port InfiniBand switches have QSFP connectors and the 96-port IB switches have X4 connects.
For an Interface node (2851-SI1) in the base rack (2851-RXA) no InfiniBand cables need to be ordered. Copper InfiniBand cables are automatically provided for all Interface nodes in the base rack. The length of the copper InfiniBand cables provided is based on the position of the Interface node in the rack.
The Management node (2851-SM1) is a 2U server containing the following:
- Two Intel Xeon E5530 (Nehalem EP) quad-core processors
- 32 GB of DDR3 memory
- Four onboard 10/100/1000 Ethernet ports (two for connecting to customer network for management access)
- Two 300 GB 2.5-inch SFF 10K RPM SAS Slim-HS hard disk drives with mirroring between the two HDDs
- One non-mirrored 300 GB 2.5-inch SFF 10K RPM SAS Slim-HS hard disk drive for centralized log/trace file collection
- Four PCIe Gen 2.0 x8 adapter slots
- Integrated Baseboard Management Controller (IBMC)
- Two redundant hot-swappable power supplies
- Six redundant hot-swappable cooling fans
The Management node provides the user interface for configuring, administering, and monitoring the SONAS system. A single Management node is required. The Management node contains two redundant hot-swappable 300 GB 2.5-inch 10K RPM SAS HDDs with mirroring between them for high-availability. The hard disk drives contain the SONAS System Software product which hosts the operating system and all other software needed for an operational SONAS system.
Two of the PCIe x8 adapter slots are already populated with two single-port 4X Double Data Rate (DDR) InfiniBand Host Channel Adapters (HCA). The two HCAs attach to two independent InfiniBand switches in the SONAS system and interconnect the Management node to the other components of the SONAS system.
The Management node comes with two InfiniBand copper cables to connect it to the two InfiniBand switches in the base rack. The primary Management node is assumed to be in the SONAS base rack with the two InfiniBand switches.
The Storage node (2851-SS1) is a 2U server containing the following:
- Two Intel Xeon E5530 (Nehalem EP) quad-core processors
- 8 GB of DDR3 memory
- Four onboard 10/100/1000 Ethernet ports
- Two 300 GB 2.5-inch SFF 10K RPM SAS Slim-HS hard disk drives with mirroring between the two HDDs
- Four PCIe Gen 2.0 x8 adapter slots
- Integrated Baseboard Management Controller (IBMC)
- Two redundant hot-swappable power supplies
- Six redundant hot-swappable cooling fans
The Storage node provides the InfiniBand connection to the InfiniBand cluster interconnect and direct fibre-channel attachment to the SONAS Storage controller. Storage nodes must be configured in high-availability (HA) pairs. The two Storage nodes in the HA pair are connected to one or two SONAS Storage controllers.
Two of the onboard Ethernet ports connect the storage node to the internal private management network, and two for a NULL Ethernet connection to the DASD Disk Storage controller.
The Storage node contains two redundant hot-swappable 300 GB 2.5-inch 10K RPM SAS HDDs with mirroring between them for high-availability. The hard disk drives contain the SONAS System Software product which hosts the operating system and all other software needed for an operational SONAS system.
All of the PCIe x8 adapter slots in the storage node are already populated with adapters. Two of the PCIe adapter slots are populated with two single-port 4X DDR InfiniBand HCAs for attaching to the two InfiniBand switches in the SONAS system. The other two PCIe x8 adapter slots are populated with two dual-port 8 Gbps Fibre Channel Host Bus Adapters (HBAs) for attaching to the SONAS Storage controller.
The SONAS Storage controller (2851-DR1) is a high-performance 4U Storage controller containing:
- Dual redundant hot-swappable RAID controllers
- Dual redundant hot-swappable power supply and cooling modules
- Support for 60 3.5-inch SAS/SATA HDDs
Each RAID controller contains:
- 4 GB of cache
- Two 8 Gbps FC host ports
- One drive-side SAS expansion port
The Storage controller supports RAID 1, 5 and 6. One high-density disk Storage expansion unit may be attached to the Storage controller. The Storage controller comes with four FC optical cables for attaching the Storage controller to the two Storage nodes.
All sixty hard disk drives in the Storage controller must be the same, therefore a quantity of six of feature #1300, #1301, or #1310 must be ordered.
The following table shows the total raw storage capacity of the Storage controller when populated with the different hard disk drive features:
Total raw
Quantity Feature Description storage capacity
6 1300 10-pack of 7.2K RPM 1 TB SATA 60 TB
6 1301 10-pack of 7.2K RPM 2 TB SATA 120 TB
6 1310 10-pack of 15K RPM 450 GB SAS 27 TB
Features #9011, #9012, #9013, and #9014 are plant-only feature and are used to indicate into which Storage controller location (1-4) this particular Storage controller is to be placed during manufacturing. The rack must be populated from the bottom of the rack (EIA position 1) to the top of the rack (EIA position 42) for stability reasons. Therefore, the following rules apply to the placement of Storage controllers within the rack:
- You may not have a Storage controller in location #4 (EIA positions 29-32) unless you have a Storage controller in location #3 (EIA positions 21-24).
- You may not have a Storage controller in location #3 (EIA positions 21-24) unless you have a Storage controller in location #2 (EIA positions 9-12).
- You may not have a Storage controller in location #2 (EIA positions 9-12) unless you have a Storage controller in location #1 (EIA positions 1-4).
Additionally, features #9013 and #9014 are not valid when plant-merging the storage controller into the Base Rack (2851-RXA), since the Base Rack only holds two Storage controllers.
The SONAS disk Storage expansion unit (2851-DE1) is a 4U high-density disk enclosure supporting 60 3.5 inch SATA or SAS hard disk drives One disk Storage expansion unit may be attached to a single SONAS Storage controller. Each disk Storage expansion unit contains the following:
- Two SAS switch modules which provide SAS connections to the storage controller
- Two redundant hot-swappable power supply and cooling units
- Support for 60 3.5-inch SAS or SATA HDDs
The Disk Storage expansion unit must be physically located in the same rack and in adjacent EIA positions as the SONAS Storage controller to which it is attaching.
All sixty hard disk drives in the disk Storage expansion unit must be the same, therefore a quantity of six of feature #1300, #1301, or #1310 must be ordered.
The following table shows the total raw storage capacity of the disk Storage expansion unit when populated with the different types of hard disk drive features:
Total raw
Quantity Feature Description storage capacity
6 1300 10-pack of 7.2K RPM 1 TB SATA 60 TB
6 1301 10-pack of 7.2K RPM 2 TB SATA 120 TB
6 1310 10-pack of 15K RPM 450 GB SAS 27 TB
Features #9021, #9022, #9023, and #9024 are plant-only features and are used to indicate into which disk Storage expansion unit location (1-4) this particular disk Storage expansion unit is to be placed during manufacturing. A disk Storage expansion unit must be attached to a Storage controller. The Storage controller attached to a disk Storage expansion unit should be in the EIA position immediately adjacent and below the disk Storage expansion unit. Therefore, the following rules apply to the placement of Storage controllers within the rack:
- You may not have a disk Storage expansion unit in disk Storage expansion unit location #1 (EIA positions 5-8) unless you have a Storage controller in Storage controller location #1 (EIA positions 1-4).
- You may not have a disk Storage expansion unit in disk Storage expansion unit location #2 (EIA positions 13-16) unless you have a Storage controller in Storage controller location #2 (EIA positions 9-12)
- You may not have a disk Storage expansion unit in disk Storage expansion unit location #3 (EIA positions 25-28) unless you have a Storage controller in storage controller location #3 (EIA positions 21-24)
- You may not have a disk Storage expansion unit in disk Storage expansion unit location #4 (EIA positions 33-36) unless you have a Storage controller in Storage controller location #4 (EIA positions 29-32)
Additionally, features #9023 and #9024 are not valid when plant-merging the Storage controller into the Base Rack (2851-RXA), since the Base Rack only holds two disk Storage expansion units.
Infiniband switches
The major components of a SONAS system (Interface node, Storage node, and Management node) are interconnected by a high-performance low-latency InfiniBand 4X Double Data Rate (DDR) fabric. Two redundant InfiniBand switches are incorporated inside each SONAS system.
For small and medium configuration, a 1U 36-port 4X DDR InfiniBand switch is available. For larger configurations a 7U 96-port 4X DDR InfiniBand switch is available. Two identical IB switches must be ordered for a SONAS system, either two 36-port IB switches or two 96-port IB switches. These IB switches are described in the following sections.
36-port IB switch
The SONAS 36-port IB switch (2851-I36) is a 4X DDR InfiniBand switch providing 36 QSFP ports, with each port operating at 20 Gbps. This IB switch provides a maximum backplane bandwidth of 1.44 Tbps and contains an embedded IB fabric manager. The switch provides two redundant hot-swap power supplies.
96-port IB switch
The 96-port IB switch (2851-I96) provides a 96-port 4X DDR InfiniBand switch providing up to 96 4X DDR X4 switch ports. The 96-port IB switch is intended for large SONAS system configurations. The IB switch provides a maximum backplane bandwidth of 3.84 Tbps. The 96-port IB switch comes standard with the following:
- Two 96-port InfiniBand Switch Fabric boards
- One 24-port 4X DDR Line Board
- One Hi-Memory Management board containing an embedded IB fabric manager
- Two Power Supply Units (PSU)
- All fan assembles
The 96-port switch comes standard with one 24-port 4X DDR line board providing 24 4X DDR (20 Gbps) IB ports. Up to three additional SLB-2024 24-port 4X DDR line boards may be added for a total of 96 ports.
The 96-port IB switch comes standard with two SLB-2004 Switch Fabric boards. Up to two additional SLB-2004 Switch Fabric boards may be added to provide additional backplane bandwidth.
The 96-port IB switch comes standard with two power supplies. Up to two additional PSUs may be added for redundancy. The two standard power supplies are capable of powering a fully configured 96-port IB switch with:
- Four SFV-2004 Switch Fabric boards
- Four SLB-2024 24-port 4X DDR line boards
- Two SMB-HM Hi-Memory Management boards
The following options may be added to the 96-port InfiniBand switch:
- FC 1500 96-port InfiniBand Switch Fabric board
- FC 1501 24-port 4X DDR InfiniBand Line Board
- FC 1502 Hi-Memory Management Board
- FC 1503 Power Supply
Accessibility by people with disabilities
A U.S. Section 508 Voluntary Product Accessibility Template (VPAT) containing details on accessibility compliance can be requested at
|
|
| Reference information |
Refer to IBM Scale Out Network Attached Storage Software Announcement 210-035, dated February 09, 2010.
|
|
| Product number |
Machine Model Feature
Description type number number
IBM System Storage SONAS 2851 SI1
Interface Node
Additional 32GB Memory 1000
Quad port 1GbE NIC 1100
Dual port 10Gb CNA 1101
10m InfiniBand X4 to QSFP optical 1220
cable
20m InfiniBand X4 to QSFP optical 1221
cable
30m InfiniBand X4 to QSFP optical 1222
cable
50m InfiniBand X4 to QSFP optical 1223
cable
10m InfinBand X4 to X4 optical 1230
cable
20m InfiniBand X4 to X4 optical 1231
cable
30m InfiniBand X4 to X4 optical 1232
cable
50m InfiniBand X4 to X4 optical 1233
cable
Plant merge into 2851 rack 9000
Field merge into 2851 rack 9001
Bulk order feature 9555
IGF transaction indicator 9556
Machine Model Feature
Description type number number
IBM System Storage SONAS 2851 SM1
Management Node
Plant merge into 2851 rack 9000
Field merge into 2851 rack 9001
IGF transaction indicator 9556
Machine Model Feature
Description type number number
IBM System Storage SONAS 2851 SS1
Storage Node
10m InfiniBand X4 to QSFP optical 1220
cable
20m InfiniBand X4 to QSFP optical 1221
cable
30m InfiniBand X4 to QSFP optical 1222
cable
50m InfiniBand X4 to QSFP optical 1223
cable
10m InfinBand X4 to X4 optical 1230
cable
20m InfiniBand X4 to X4 optical 1231
cable
30m InfiniBand X4 to X4 optical 1232
cable
50m InfiniBand X4 to X4 optical 1233
cable
Plant merge into 2851 rack 9000
Field merge into 2851 rack 9001
Bulk order feature 9555
IGF transaction indicator 9556
Machine Model Feature
Description type number number
IBM System Storage SONAS 2851 DR1
Storage Controller
10-pack of 7.2K RPM 1TB SATA HDDs 1300
10-pack of 7.2K RPM 2TB SATA HDDs 1301
10-pack of 15K RPM 450GB SAS HDDs 1310
Plant merge into 2851 rack 9000
Field merge into 2851 rack 9001
Plant install 1st storage controller 9011
(EIA positions 1-4)
Plant install 2nd storage controller 9012
(EIA positions 9-12)
Plant install 3rd storage controller 9013
(EIA positions 21-24)
Plant install 4th storage controller 9014
(EIA positions 29-32)
Bulk order feature 9555
IGF transaction indicator 9556
Install in Base Rack 9800
Install in Storage Expansion Rack #1 9801
Install in Storage Expansion Rack #2 9802
Install in Storage Expansion Rack #3 9803
Install in Storage Expansion Rack #4 9804
Install in Storage Expansion Rack #5 9805
Install in Storage Expansion Rack #6 9806
Install in Storage Expansion Rack #7 9807
Install in Storage Expansion Rack #8 9808
Install in Storage Expansion Rack #9 9809
Install in Storage Expansion Rack 9810
#10
Install in Storage Expansion Rack 9811
#11
Install in Storage Expansion Rack 9812
#12
Install in Storage Expansion Rack 9813
#13
Install in Storage Expansion Rack 9814
#14
Install in Storage Expansion Rack 9815
#15
Machine Model Feature
Description type number number
IBM System Storage SONAS 2851 DE1
Disk Storage Expansion unit (DSE)
10-pack of 7.2K RPM 1TB SATA HDDs 1300
10-pack of 7.2K RPM 2TB SATA HDDs 1301
10-pack of 15K RPM 450GB SAS HDDs 1310
Plant merge into 2851 rack 9000
Field merge into 2851 rack 9001
Plant install 1st DES unit 9021
(EIA positions 5-8)
Plant install 2nd DES unit 9022
(EIA positions 13-16)
Plant install 3rd DES unit 9023
(EIA positions 25-28)
Plant install 4th DES unit 9024
(EIA positions 33-36)
Bulk order feature 9555
IGF transaction indicator 9556
Install in Base Rack 9800
Install in Storage Expansion Rack #1 9801
Install in Storage Expansion Rack #2 9802
Install in Storage Expansion Rack #3 9803
Install in Storage Expansion Rack #4 9804
Install in Storage Expansion Rack #5 9805
Install in Storage Expansion Rack #6 9806
Install in Storage Expansion Rack #7 9807
Install in Storage Expansion Rack #8 9808
Install in Storage Expansion Rack #9 9809
Install in Storage Expansion Rack 9810
#10
Install in Storage Expansion Rack 9811
#11
Install in Storage Expansion Rack 9812
#12
Install in Storage Expansion Rack 9813
#13
Install in Storage Expansion Rack 9814
#14
Install in Storage Expansion Rack 9815
#15
Machine Model Feature
Description type number number
IBM System Storage SONAS 2851 I36
36-port InfiniBand Switch
Plant merge into 2851 rack 9000
Field merge into 2851 rack 9001
IGF transaction indicator 9556
Machine Model Feature
Description type number number
IBM System Storage SONAS 2851 I96
96-port InfiniBand Switch
96-port InfiniBand Switch Fabric 1500
boards
24-port 4X DDR InfiniBand 1501
Line Board
Hi-memory Management 1502
board
Power supply 1503
Plant merge into 2851 rack 9000
Field merge into 2851 rack 9001
IGF transaction indicator 9556
Machine Model Feature
Description type number number
IBM System Storage SONAS 2851 RXA
Base Rack
Two 50-port 10/100/1000 Level 2 0100
Ethernet switches
Service Ladder 0101
Plant install interface node 5000
Field install interface node (MES) 5001
Plant install management node 5002
Plant install storage node 5004
Field install storage node (MES) 5005
Plant install storage controller 5006
Field install storage controller 5007
(MES)
Plant install disk storage expansion 5008
unit
Field install disk storage expansion 5009
unit (MES)
Plant install 36-port IB switch 5010
Plant install 96-port IB switch 5011
Standard front and rear doors 6070
Suite Attach Kit 2m rack 6086
Side Panel 6098
Acoustic front and rear doors 6249
Rear Door Heat Exchanger 6858
Side mount 1-phase PDUs 7188
Intelligent PDUs 7192
Config #1, 36-port IB switches, 9003
interface nodes only
Config #2, 96-port IB switches, 9004
interface nodes only
Config #,3, 36-port IB switches, 9005
interface nodes and storage pod
Power cord 1-ph, NEMA L6-30 9854
Power cord 1-ph IEC309, P+N+G 9856
32A
Power cord 1-ph Aust./New Zealand 9857
Power cord 1-ph, 250Vac Korea 9858
Machine Model Feature
Description type number number
IBM System Storage SONAS 2851 RXB
Storage expansion rack
Two 50-port 10/100/1000 Level 2 0100
Ethernet switches
Plant install storage node 5004
Field install storage node (MES) 5005
Plant install storage controller 5006
Field install storage controller 5007
(MES)
Plant install disk storage expansion 5008
unit
Field install disk storage expansion 5009
unit (MES)
Standard front and rear doors 6070
Suite Attach Kit 2m rack 6086
Side Panel 6098
Acoustic front and rear doors 6249
Rear Door Heat Exchanger 6858
Side mount 1-phase PDUs 7188
Intelligent PDUs 7192
Storage expansion rack #1 9701
Storage expansion rack #2 9702
Storage expansion rack #3 9703
Storage expansion rack #4 9704
Storage expansion rack #5 9705
Storage expansion rack #6 9706
Storage expansion rack #7 9707
Storage expansion rack #8 9708
Storage expansion rack #9 9709
Storage expansion rack #10 9710
Storage expansion rack #11 9711
Storage expansion rack #12 9712
Storage expansion rack #13 9713
Storage expansion rack #14 9714
Storage expansion rack #15 9715
Power cord 1-ph, NEMA L6-30 9854
Power cord 1-ph IEC309, P+N+G 9856
32A
Power cord 1-ph Aust./New Zealand 9857
Power cord 1-ph, 250Vac Korea 9858
Machine Model Feature
Description type number number
IBM System Storage SONAS 2851 RXC
Interface expansion rack
Two 50-port 10/100/1000 Level 2 0100
Ethernet switches
Plant install interface node 5000
Field install interface node (MES) 5001
Standard front and rear doors 6070
Suite Attach Kit 2m rack 6086
Side Panel 6098
Acoustic front and rear doors 6249
Rear Door Heat Exchanger 6858
Side mount 1-phase PDUs 7188
Intelligent PDUs 7192
Power cord 1-ph, NEMA L6-30 9854
Power cord 1-ph IEC309, P+N+G 9856
32A
Power cord 1-ph Aust./New Zealand 9857
Power cord 1-ph, 250Vac Korea 9858
Model conversions
Not applicable
Feature conversions
Not applicable
|
|
| Education support |
Call IBM IT Education Services at 800-IBM-TEACH (426-8322) for catalogs, schedules, and enrollments.
|
|
| Publications |
Information about IBM Scale Out Network Attached Storage (SONAS) is provided on the Internet in the SONAS Information Center. The SONAS Information Center is also accessible through the product interface for easy access to task-specific topics. Adobe® Acrobat PDF versions of the content for browsing or printing are also in the SONAS Information Center and available as no-charge downloads from the IBM Publications Web site. In addition, a CD-ROM containing the SONAS product documentation is shipped with each order. To access the latest SONAS product information, see the IBM Scale Out Network Attached Storage Information Center at
The following publications are shipped with the product.
Order Part
Title number number
Environmental Notices and User Guide Z125-5823-02 29R2153
IBM Translated Safety Notices G229-9054-02 45D6431
IBM Statement of Limited Warranty GA32-0722-00 46X2375
IBM License Agreement for Machine Code Z125-5468-04 49Y017
The following publications will be available at product availability. To order, contact your IBM representative.
Order Part
Title number number
SONAS Software Administration Guide GA32-0713-00 N/A
IBM Scale Out Network Attached GA32-0718-00 N/A
Storage Software Configuration Guide
SONAS User's Guide GA32-0714-00 N/A
SONAS Installation Guide GA32-0715-00 N/A
SONAS Introduction & Planning Guide GA32-0716-00 N/A
Problem Determination and GA32-0717-00 N/A
Troubleshooting Guide
IBM Publications Center Portal
The Publications Center is a worldwide central repository for IBM product publications and marketing material with a catalog of 70,000 items. Extensive search facilities are provided, as well as payment options via credit card. A large number of publications are available online in various file formats, which can currently be downloaded free of charge.
Additional copies are available. To order, contact your IBM representative. These publications are also available at the following Web site
The IBM Publications Center Portal
An online IBM information center will be available on the general availability date at the following Web site
|
|
| Services |
Global Technology Services
Support for installation and general technical support can be provided by local Field Technical Support Specialists (FTSS). You can also purchase complete planning, installation, implementation and configuration service from IBM Global Services. The list of selected services available in your region, either as standard or customized offerings, for the efficient installation, implementation, or integration of this product can be obtained from your respective IBM GTS regional offering executive. Implementation services for the SONAS appliance will be available at the time of SONAS product general availability or ship date:
Offering ID Description
6948-K11 Implementation Services for Network Attached Storage
systems - IBM Scale Out Network Attached Storage (SONAS)
IBM services include business consulting, outsourcing, hosting services, applications, and other technology management.
These services help you learn about, plan, install, manage, or optimize your IT infrastructure to be an On Demand Business. They can help you integrate your high-speed networks, storage systems, application servers, wireless protocols, and an array of platforms, middleware, and communications software for IBM and many non-IBM offerings. IBM is your one-stop shop for IT support needs.
For details on available services, contact your IBM representative or visit
For details on available IBM Business Continuity and Recovery Services, contact your IBM representative or visit
For details on education offerings related to specific products, visit
Select your country, and then select the product as the category.
|
|
| Technical information |
Specified operating environment
Physical specifications
Width: 644 mm (25.4 in.)
Depth: 1608 mm (63.3 in.)
Height: 2015 mm (79.3 in.)
Fully populated
Model Weight
2851-RXA FC 9003 794 Kg (1750 lbs)
2851-RXA FC 9004 749 Kg (1650 lbs)
2851-RXA FC 9005 1044 Kg (2300 lbs)
2851-RXB 1343 Kg (2960 lbs)
2851-RXC 817 Kg (1800 lbs)
Operating environment
- Operating temperature maximum range
- 10 C to 35° C (50 F to 95° F) at 900 m or less
- Recommended operating temperature range
- 20 C to 25° C (68 F to 77° F)
- Operating relative humidity range
- 40% to 55% non-condensing
- Non-operating temperature range
- 5 C to 45° C (41 F to 113° F )
- Non-operating relative humidity range
- 8% to 80% non-condensing
- Shipping temperature range
- - 40 C to 60° C (-40 F to 140° F)
- Shipping relative humidity range
- 5% to 100% non-condensing
|
|
| Recommended Power ratings for 2851 (per line cord) |
Inrush
Frequency Current current Power
Product Voltage (Hz) (Amps) (A) (Watts) KVA Kbtu/hr
2851-RXA 200-240 50-60 24 300 4800 4.8 16.4
2851-RXB 200-240 50-60 24 300 4800 4.8 16.4
2851-RXC 200-240 50-60 24 300 4800 4.8 16.4
2851-I36 100-240 50-60 5 N/A 500 0.5 1.7
2851-I96 100-240 50-60 15 N/A 1500 1.5 5.2
2851-DE1 200-240 50-60 10 N/A 2000 2.0 6.9
2851-DR1 200-240 50-60 10 N/A 2000 2.0 6.9
2851-SI1 100-127 50-60 7.8 N/A 780 0.78 2.7
SS1,SM1 /200-240 /3.8
Software requirements
The SONAS SW PID (5639-SN1) is a corequisite of the management, interface, and storage hardware nodes (2851-SI1, -SM1, -SS1), and must be ordered concurrently with the proper chargeable feature.
Planning information
Customer responsibilities
The IBM Scale Out Network Attached Storage machine type (2851) is designated as Customer Engineer (CE) installable. CE setup, operation, and service publications are available.
You are responsible for downloading or obtaining from IBM, and installing designated Machine Code (microcode, basic input/output system code (called "BIOS"), utility programs, device drivers, and diagnostics delivered with an IBM machine) and other software updates in a timely manner from an IBM Internet Web site or from other electronic media, and following the instructions that IBM provides. You may request IBM to install Machine Code changes; however, you may be charged for that service.
Cable orders
It is the customer's responsibility to provide the appropriate type for connecting the host or network and the 2851.
The cables to connect the various components of the 2851 must be ordered on the initial order and replacements can be obtained by ordering via MES.
Security, auditability, and control
This product uses the security and auditability features of the host hardware, host software, and/or application software to which it is attached.
The customer is responsible for evaluation, selection, and implementation of security features, administrative procedures, and appropriate controls in application systems and communications facilities.
|
|
| IBM Electronic Services |
IBM has transformed its delivery of hardware and software support services to help you achieve higher system availability. Electronic Services is a Web-enabled solution that offers an exclusive, no-additional-charge enhancement to the service and support available for IBM servers. These services are designed to provide the opportunity for greater system availability with faster problem resolution and preemptive monitoring. Electronic Services comprises two separate, but complementary, elements: Electronic Services news page and Electronic Services Agent.
The Electronic Services news page is a single Internet entry point that replaces the multiple entry points traditionally used to access IBM Internet services and support. The news page enables you to gain easier access to IBM resources for assistance in resolving technical problems.
The Electronic Service Agent is no-additional-charge software that resides on your server. It monitors events and transmits system inventory information to IBM on a periodic, client-defined timetable. The Electronic Service Agent automatically reports hardware problems to IBM. Early knowledge about potential problems enables IBM to deliver proactive service that may result in higher system availability and performance. In addition, information collected through the Service Agent is made available to IBM service support representatives when they help answer your questions or diagnose problems. Installation and use of IBM Electronic Service Agent for problem reporting enables IBM to provide better support and service for your IBM server.
To learn how Electronic Services can work for you, visit
|
|
| Terms and conditions |
IBM Global Financing
Yes
Warranty period
One year
Warranty service
If required, IBM provides repair or exchange service depending on the types of warranty service specified for the machine. IBM will attempt to resolve your problem over the telephone, or electronically via an IBM Web site. You must follow the problem determination and resolution procedures that IBM specifies. Scheduling of service will depend upon the time of your call and is subject to parts availability. If applicable to your product, parts considered Customer Replaceable Units (CRUs) will be provided as part of the machine's standard warranty service.
Service levels are response-time objectives and are not guaranteed. The specified level of warranty service may not be available in all worldwide locations. Additional charges may apply outside IBM's normal service area. Contact your local IBM representative or your reseller for country- and location-specific information.
CRU Service
IBM provides replacement CRUs to you for you to install. CRU information and replacement instructions are shipped with your machine and are available from IBM upon your request. CRUs are designated as being either a Tier 1 or a Tier 2 CRU.
Tier 1 CRU
Installation of Tier 1 CRUs is your responsibility. If IBM installs a Tier 1 CRU at your request, you will be charged for the installation.
Tier 2 CRU
You may install a Tier 2 CRU yourself or request IBM to install it, at no additional charge.
Based upon availability, CRUs will be shipped for next business day (NBD) delivery. IBM specifies, in the materials shipped with a replacement CRU, whether a defective CRU must be returned to IBM. When return is required, return instructions and a container are shipped with the replacement CRU, you may be charged for the replacement CRU if IBM does not receive the defective CRU within 15 days of your receipt of the replacement.
The following parts have been designated as Tier 1 CRUs:
- Hard disk drive
- Optical drive
- Fan
- I/O adapters
- Operator panel
- PCI adapters
- Power cord
- Power supply
- Processor power regulator
- Service processor
On-site Service
IBM will repair the failing machine at your location and verify its operation. You must provide a suitable working area to allow disassembly and reassembly of the IBM machine. The area must be clean, well lit, and suitable for the purpose.
The service level is:
- 9 hours per day, Monday through Friday, excluding holidays, next business day response. Calls must be received by 5 p.m. local time in order to qualify for next business day response.
- 9 hours per day, Monday through Friday, excluding holidays, 4 hour average, same business day response. Same business day service level includes the installation of Tier 1 CRUs at no additional charge.
- 24 hours per day, 7 days a week, 4 hour average, same day response. Same day service level includes the installation of Tier 1 CRUs at no additional charge.
Warranty service upgrades
During the warranty period, warranty service upgrades provide an enhanced level of On-site Service for an additional charge. Service levels are response-time objectives and are not guaranteed. See the Warranty services section for additional details.
IBM will attempt to resolve your problem over the telephone or electronically by access to an IBM Web site. You must follow the problem determination and resolution procedures that IBM specifies. Scheduling of service will depend upon the time of your call and is subject to parts availability.
Maintenance service options
On-site Service
IBM will repair the failing machine at your location and verify its operation. You must provide a suitable working area to allow disassembly and reassembly of the IBM machine. The area must be clean, well lit, and suitable for the purpose. The following on-site response-time objectives are available as warranty service upgrades for your machine. Available offerings are:
- 9 hours per day, Monday through Friday, excluding holidays, 4 hour average, same business day response
- 24 hours per day, 7 days a week, 4 hour average response
- 24 hours per day, 7 days a week, 2 hour average response
Customer Replaceable Units (CRUs) may be provided as part of the machine's standard warranty CRU Service except that you may install a CRU yourself or request IBM installation, at no additional charge, under one of the On-site Service levels specified above. For additional information on the CRU Service, see the warranty information.
Maintenance services
If required, IBM provides repair or exchange service depending on the types of maintenance service specified for the machine. IBM will attempt to resolve your problem over the telephone or electronically, via an IBM Web site. You must follow the problem determination and resolution procedures that IBM specifies. Scheduling of service will depend upon the time of your call and is subject to parts availability. Service levels are response-time objectives and are not guaranteed. The specified level of maintenance service may not be available in all worldwide locations. Additional charges may apply outside IBM's normal service area. Contact your local IBM representative or your reseller for country- and location-specific information. The following service selections are available as maintenance options for your machine type.
On-site Service
IBM will repair the failing machine at your location and verify its operation. You must provide a suitable working area to allow disassembly and reassembly of the IBM machine. The area must be clean, well lit, and suitable for the purpose.
Service levels are:
- 9 hours per day, Monday through Friday, excluding holidays, next business day response
- 9 hours per day, Monday through Friday, excluding holidays, 4 hour average response
- 24 hours per day, 7 days a week, 4 hour average response
- 24 hours per day, 7 days a week, 2 hour average response
Customer Replaceable Unit (CRU) Service
If your problem can be resolved with a CRU (for example, keyboard, mouse, speaker, memory, or hard disk drive), and depending upon the maintenance service offerings in your geography, IBM will ship the CRU to you for you to install. CRU information and replacement instructions are shipped with your machine and are available from IBM upon your request.
Based upon availability, CRUs will be shipped for next business day delivery. IBM specifies, in the materials shipped with a replacement CRU, whether a defective CRU must be returned to IBM. When return is required, return instructions and a container are shipped with the replacement CRU and you may be charged for the replacement CRU if IBM does not receive the defective CRU within 15 days of your receipt of the replacement.
CRUs may be provided as part of the machine's standard maintenance service except that you may install a CRU yourself or request IBM installation, at no additional charge, under any of the On-site Service levels specified above.
Usage plan machine
No
IBM hourly service rate classification
Three.
When a type of service involves the exchange of a machine part, the replacement may not be new, but will be in good working order.
Field-installable features
Yes
Model conversions
No
Machine installation
Installation is performed by IBM. IBM will install the machine in accordance with the IBM installation procedures for the machine. In the United States, contact IBM at 1-800-IBM-SERV (426-7378). In other countries, contact the local IBM office. A Systems Assurance Review is mandatory for this product. The SAR will qualify the site environment and capture customer requirements for a custom manufacturing build prior to the IBM installation.
Graduated program license charges apply
No
Licensed machine code
IBM Machine Code is licensed for use by a customer on the IBM machine for which it was provided by IBM under the terms and conditions of the IBM License Agreement for Machine Code, to enable the machine to function in accordance with its specifications, and only for the capacity authorized by IBM and acquired by the customer. You can obtain the agreement at
IBM may release changes to the Machine Code. IBM plans to make the Machine Code changes available for download from the IBM System Storage technical support Web site:
You may also obtain updated code by contacting your IBM representative.
If the machine does not function as warranted and your problem can be resolved through your application of downloadable Machine Code, you are responsible for downloading and installing these designated Machine Code changes as IBM specifies. If you would prefer, you may request IBM to install downloadable Machine Code changes; however, you may be charged for that service.
Educational allowance
A reduced charge is available to qualified education customers. The educational allowance may not be added to any other discount or allowance.
The educational allowance is 15% for the products in this announcement.
|
|
| Prices |
Product charges
Machine Model Feature
Description type number number
IBM System Storage SONAS 2851 SI1
Interface Node
Additional 32GB Memory 1000
Quad port 1GbE NIC 1100
Dual port 10Gb CNA 1101
10m InfiniBand X4 to QSFP optical 1220
cable
20m InfiniBand X4 to QSFP optical 1221
cable
30m InfiniBand X4 to QSFP optical 1222
cable
50m InfiniBand X4 to QSFP optical 1223
cable
10m InfinBand X4 to X4 optical 1230
cable
20m InfiniBand X4 to X4 optical 1231
cable
30m InfiniBand X4 to X4 optical 1232
cable
50m InfiniBand X4 to X4 optical 1233
cable
Plant merge into 2851 rack 9000
Field merge into 2851 rack 9001
Bulk order feature 9555
IGF transaction indicator 9556
IBM System Storage SONAS 2851 SM1
Management Node
Plant merge into 2851 rack 9000
Field merge into 2851 rack 9001
IGF transaction indicator 9556
IBM System Storage SONAS 2851 SS1
Storage Node
10m InfiniBand X4 to QSFP optical 1220
cable
20m InfiniBand X4 to QSFP optical 1221
cable
30m InfiniBand X4 to QSFP optical 1222
cable
50m InfiniBand X4 to QSFP optical 1223
cable
10m InfinBand X4 to X4 optical 1230
cable
20m InfiniBand X4 to X4 optical 1231
cable
30m InfiniBand X4 to X4 optical 1232
cable
50m InfiniBand X4 to X4 optical 1233
cable
Plant merge into 2851 rack 9000
Field merge into 2851 rack 9001
Bulk order feature 9555
IGF transaction indicator 9556
IBM System Storage SONAS 2851 DR1
Storage Controller
10-pack of 7.2K RPM 1TB SATA HDDs 1300
10-pack of 7.2K RPM 2TB SATA HDDs 1301
10-pack of 15K RPM 450GB SAS HDDs 1310
Plant merge into 2851 rack 9000
Field merge into 2851 rack 9001
Plant install 1st storage controller 9011
(EIA positions 1-4)
Plant install 2nd storage controller 9012
(EIA positions 9-12)
Plant install 3rd storage controller 9013
(EIA positions 21-24)
Plant install 4th storage controller 9014
(EIA positions 29-32)
Bulk order feature 9555
IGF transaction indicator 9556
Install in Base Rack 9800
Install in Storage Expansion Rack #1 9801
Install in Storage Expansion Rack #2 9802
Install in Storage Expansion Rack #3 9803
Install in Storage Expansion Rack #4 9804
Install in Storage Expansion Rack #5 9805
Install in Storage Expansion Rack #6 9806
Install in Storage Expansion Rack #7 9807
Install in Storage Expansion Rack #8 9808
Install in Storage Expansion Rack #9 9809
Install in Storage Expansion Rack 9810
#10
Install in Storage Expansion Rack 9811
#11
Install in Storage Expansion Rack 9812
#12
Install in Storage Expansion Rack 9813
#13
Install in Storage Expansion Rack 9814
#14
Install in Storage Expansion Rack 9815
#15
IBM System Storage SONAS 2851 DE1
Disk Storage Expansion unit (DSE)
10-pack of 7.2K RPM 1TB SATA HDDs 1300
10-pack of 7.2K RPM 2TB SATA HDDs 1301
10-pack of 15K RPM 450GB SAS HDDs 1310
Plant merge into 2851 rack 9000
Field merge into 2851 rack 9001
Plant install 1st DES unit 9021
(EIA positions 5-8)
Plant install 2nd DES unit 9022
(EIA positions 13-16)
Plant install 3rd DES unit 9023
(EIA positions 25-28)
Plant install 4th DES unit 9024
(EIA positions 33-36)
Bulk order feature 9555
IGF transaction indicator 9556
Install in Base Rack 9800
Install in Storage Expansion Rack #1 9801
Install in Storage Expansion Rack #2 9802
Install in Storage Expansion Rack #3 9803
Install in Storage Expansion Rack #4 9804
Install in Storage Expansion Rack #5 9805
Install in Storage Expansion Rack #6 9806
Install in Storage Expansion Rack #7 9807
Install in Storage Expansion Rack #8 9808
Install in Storage Expansion Rack #9 9809
Install in Storage Expansion Rack 9810
#10
Install in Storage Expansion Rack 9811
#11
Install in Storage Expansion Rack 9812
#12
Install in Storage Expansion Rack 9813
#13
Install in Storage Expansion Rack 9814
#14
Install in Storage Expansion Rack 9815
#15
IBM System Storage SONAS 2851 I36
36-port InfiniBand Switch
Plant merge into 2851 rack 9000
Field merge into 2851 rack 9001
IGF transaction indicator 9556
IBM System Storage SONAS 2851 I96
96-port InfiniBand Switch
96-port InfiniBand Switch Fabric 1500
boards
24-port 4X DDR InfiniBand 1501
Line Board
Hi-memory Management 1502
board
Power supply 1503
Plant merge into 2851 rack 9000
Field merge into 2851 rack 9001
IGF transaction indicator 9556
IBM System Storage SONAS 2851 RXA
Base Rack
Two 50-port 10/100/1000 Level 2 0100
Ethernet switches
Service Ladder 0101
Plant install interface node 5000
Field install interface node (MES) 5001
Plant install management node 5002
Plant install storage node 5004
Field install storage node (MES) 5005
Plant install storage controller 5006
Field install storage controller 5007
(MES)
Plant install disk storage expansion 5008
unit
Field install disk storage expansion 5009
unit (MES)
Plant install 36-port IB switch 5010
Plant install 96-port IB switch 5011
Standard front and rear doors 6070
Suite Attach Kit 2m rack 6086
Side Panel 6098
Acoustic front and rear doors 6249
Rear Door Heat Exchanger 6858
Side mount 1-phase PDUs 7188
Intelligent PDUs 7192
Config #1, 36-port IB switches, 9003
interface nodes only
Config #2, 96-port IB switches, 9004
interface nodes only
Config #,3, 36-port IB switches, 9005
interface nodes and storage pod
Power cord 1-ph, NEMA L6-30 9854
Power cord 1-ph IEC309, P+N+G 9856
32A
Power cord 1-ph Aust./New Zealand 9857
Power cord 1-ph, 250Vac Korea 9858
IBM System Storage SONAS 2851 RXB
Storage expansion rack
Two 50-port 10/100/1000 Level 2 0100
Ethernet switches
Plant install storage node 5004
Field install storage node (MES) 5005
Plant install storage controller 5006
Field install storage controller 5007
(MES)
Plant install disk storage expansion 5008
unit
Field install disk storage expansion 5009
unit (MES)
Standard front and rear doors 6070
Suite Attach Kit 2m rack 6086
Side Panel 6098
Acoustic front and rear doors 6249
Rear Door Heat Exchanger 6858
Side mount 1-phase PDUs 7188
Intelligent PDUs 7192
Storage expansion rack #1 9701
Storage expansion rack #2 9702
Storage expansion rack #3 9703
Storage expansion rack #4 9704
Storage expansion rack #5 9705
Storage expansion rack #6 9706
Storage expansion rack #7 9707
Storage expansion rack #8 9708
Storage expansion rack #9 9709
Storage expansion rack #10 9710
Storage expansion rack #11 9711
Storage expansion rack #12 9712
Storage expansion rack #13 9713
Storage expansion rack #14 9714
Storage expansion rack #15 9715
Power cord 1-ph, NEMA L6-30 9854
Power cord 1-ph IEC309, P+N+G 9856
32A
Power cord 1-ph Aust./New Zealand 9857
Power cord 1-ph, 250Vac Korea 9858
IBM System Storage SONAS 2851 RXC
Interface expansion rack
Two 50-port 10/100/1000 Level 2 0100
Ethernet switches
Plant install interface node 5000
Field install interface node (MES) 5001
Standard front and rear doors 6070
Suite Attach Kit 2m rack 6086
Side Panel 6098
Acoustic front and rear doors 6249
Rear Door Heat Exchanger 6858
Side mount 1-phase PDUs 7188
Intelligent PDUs 7192
Power cord 1-ph, NEMA L6-30 9854
Power cord 1-ph IEC309, P+N+G 9856
32A
Power cord 1-ph Aust./New Zealand 9857
Power cord 1-ph, 250Vac Korea 9858
Machine
Model
Feature Plant/Field MES
Mach/Mod/Feat install removal CSU
2851/SI1/1000 Both No No
2851/SI1/1100 Both No No
2851/SI1/1101 Both No No
2851/SI1/1220 Both No No
2851/SI1/1221 Both No No
2851/SI1/1222 Both No No
2851/SI1/1223 Both No No
2851/SI1/1230 Both No No
2851/SI1/1230 Both No No
2851/SI1/1231 Both No No
2851/SI1/1232 Both No No
2851/SI1/1233 Both No No
2851/SI1/9000 Plant No No
2851/SI1/9001 Plant No No
2851/SI1/9555 Field No No
2851/SI1/9556 Plant No No
2851/SM1/9000 Plant No No
2851/SM1/9001 Plant No No
2851/SM1/9556 Plant No No
2851/SS1/1220 Both No No
2851/SS1/1221 Both No No
2851/SS1/1222 Both No No
2851/SS1/1223 Both No No
2851/SS1/1230 Both No No
2851/SS1/1231 Both No No
2851/SS1/1232 Both No No
2851/SS1/1233 Both No No
2851/SS1/9000 Plant No No
2851/SS1/9001 Plant No No
2851/SS1/9555 Field No No
2851/SS1/9556 Plant No No
2851/DR1/1300 Both No No
2851/DR1/1301 Both No No
2851/DR1/1310 Both No No
2851/DR1/9000 Plant No No
2851/DR1/9001 Plant No No
2851/DR1/9011 Plant No No
2851/DR1/9012 Plant No No
2851/DR1/9013 Plant No No
2851/DR1/9014 Plant No No
2851/DR1/9555 Field No No
2851/DR1/9556 Plant No No
2851/DR1/9800 Plant No No
2851/DR1/9801 Plant No No
2851/DR1/9802 Plant No No
2851/DR1/9803 Plant No No
2851/DR1/9804 Plant No No
2851/DR1/9805 Plant No No
2851/DR1/9806 Plant No No
2851/DR1/9807 Plant No No
2851/DR1/9808 Plant No No
2851/DR1/9809 Plant No No
2851/DR1/9810 Plant No No
2851/DR1/9811 Plant No No
2851/DR1/9812 Plant No No
2851/DR1/9813 Plant No No
2851/DR1/9814 Plant No No
2851/DR1/9815 Plant No No
2851/DE1/1300 Both No No
2851/DE1/1301 Both No No
2851/DE1/1310 Both No No
2851/DE1/9000 Plant No No
2851/DE1/9001 Plant No No
2851/DE1/9021 Plant No No
2851/DE1/9022 Plant No No
2851/DE1/9023 Plant No No
2851/DE1/9024 Plant No No
2851/DE1/9555 Field No No
2851/DE1/9556 Plant No No
2851/DE1/9800 Plant No No
2851/DE1/9801 Plant No No
2851/DE1/9802 Plant No No
2851/DE1/9803 Plant No No
2851/DE1/9804 Plant No No
2851/DE1/9805 Plant No No
2851/DE1/9806 Plant No No
2851/DE1/9807 Plant No No
2851/DE1/9808 Plant No No
2851/DE1/9809 Plant No No
2851/DE1/9810 Plant No No
2851/DE1/9811 Plant No No
2851/DE1/9812 Plant No No
2851/DE1/9813 Plant No No
2851/DE1/9814 Plant No No
2851/DE1/9815 Plant No No
2851/I36/9000 Plant No No
2851/I36/9001 Plant No No
2851/I36/9556 Plant No No
2851/I96/1500 Both No No
2851/I96/1501 Both No No
2851/I96/1502 Both No No
2851/I96/1503 Both No No
2851/I96/1500 Both No No
2851/I96/9000 Plant No No
2851/I96/9001 Plant No No
2851/I96/9556 Plant No No
2851/RXA/0100 Plant No No
2851/RXA/0101 Both No No
2851/RXA/5000 Plant No No
2851/RXA/5001 Field No No
2851/RXA/5002 Plant No No
2851/RXA/5004 Plant No No
2851/RXA/5005 Field No No
2851/RXA/5006 Plant No No
2851/RXA/5007 Field No No
2851/RXA/5008 Plant No No
2851/RXA/5009 Field No No
2851/RXA/5010 Plant No No
2851/RXA/5011 Plant No No
2851/RXA/6070 Both No No
2851/RXA/6086 Both No No
2851/RXA/6098 Both No No
2851/RXA/6249 Both No No
2851/RXA/6858 Both No No
2851/RXA/7188 Plant No No
2851/RXA/7192 Plant No No
2851/RXA/9003 Plant No No
2851/RXA/9004 Plant No No
2851/RXA/9005 Plant No No
2851/RXA/9854 Both No No
2851/RXA/9856 Both No No
2851/RXA/9857 Both No No
2851/RXA/9858 Both No No
2851/RXB/0100 Plant No No
2851/RXB/5004 Plant No No
2851/RXB/5005 Field No No
2851/RXB/5006 Plant No No
2851/RXB/5007 Field No No
2851/RXB/5008 Plant No No
2851/RXB/5009 Field No No
2851/RXB/6070 Both No No
2851/RXB/6086 Both No No
2851/RXB/6098 Both No No
2851/RXB/6249 Both No No
2851/RXB/6858 Both No No
2851/RXB/7188 Plant No No
2851/RXB/7192 Plant No No
2851/RXB/9701 Plant No No
2851/RXB/9702 Plant No No
2851/RXB/9703 Plant No No
2851/RXB/9704 Plant No No
2851/RXB/9705 Plant No No
2851/RXB/9706 Plant No No
2851/RXB/9707 Plant No No
2851/RXB/9708 Plant No No
2851/RXB/9709 Plant No No
2851/RXB/9710 Plant No No
2851/RXB/9711 Plant No No
2851/RXB/9712 Plant No No
2851/RXB/9713 Plant No No
2851/RXB/9714 Plant No No
2851/RXB/9715 Plant No No
2851/RXB/9854 Both No No
2851/RXB/9856 Both No No
2851/RXB/9857 Both No No
2851/RXB/9858 Both No No
2851/RXC/0100 Plant No No
2851/RXC/5000 Plant No No
2851/RXC/5001 Field No No
2851/RXC/6070 Both No No
2851/RXC/6086 Both No No
2851/RXC/6098 Both No No
2851/RXC/6249 Both No No
2851/RXC/6858 Both No No
2851/RXC/7188 Plant No No
2851/RXC/7192 Plant No No
2851/RXC/9854 Both No No
2851/RXC/9856 Both No No
2851/RXC/9857 Both No No
2851/RXC/9858 Both No No
| Mach | Feat | IBM | ||
| type | Model | code | Description | list price |
| 2851 | SI1 | Interface Node | $8,547 | |
| 2851 | SI1 | 1000 | Additional 32GB Memory | $1,410 |
| 2851 | SI1 | 1100 | Quad port 1GbE NIC | $529 |
| 2851 | SI1 | 1101 | Dual port 10Gb CNA | $2,999 |
| 2851 | SI1 | 1220 | 10m InfiniBand X4 to QSFP optical cable | $1,733 |
| 2851 | SI1 | 1221 | 20m InfiniBand X4 to QSFP optical cable | $1,870 |
| 2851 | SI1 | 1222 | 30m InfiniBand X4 to QSFP optical cable | $2,008 |
| 2851 | SI1 | 1223 | 50m InfiniBand X4 to QSFP optical cable | $2,283 |
| 2851 | SI1 | 1230 | 10m InfinBand X4 to X4 optical cable | $1,733 |
| 2851 | SI1 | 1231 | 20m InfiniBand X4 to X4 optical cable | $1,870 |
| 2851 | SI1 | 1232 | 30m InfiniBand X4 to X4 optical cable | $2,008 |
| 2851 | SI1 | 1233 | 50m InfiniBand X4 to X4 optical cable | $2,283 |
| 2851 | SI1 | 9000 | Plant merge into 2851 rack | $0 |
| 2851 | SI1 | 9001 | Field merge into 2851 rack | $0 |
| 2851 | SI1 | 9555 | Bulk order feature | $0 |
| 2851 | SI1 | 9556 | IGF transaction indicator | $0 |
| 2851 | SM1 | Management Node | $9,206 | |
| 2851 | SM1 | 9000 | Plant merge into 2851 rack | $0 |
| 2851 | SM1 | 9001 | Field merge into 2851 rack | $0 |
| 2851 | SM1 | 9556 | IGF transaction indicator | $0 |
| 2851 | SS1 | Storage Node | $12,897 | |
| 2851 | SS1 | 1220 | 10m InfiniBand X4 to QSFP optical cable | $1,733 |
| 2851 | SS1 | 1221 | 20m InfiniBand X4 to QSFP optical cable | $1,870 |
| 2851 | SS1 | 1222 | 30m InfiniBand X4 to QSFP optical cable | $2,008 |
| 2851 | SS1 | 1223 | 50m InfiniBand X4 to QSFP optical cable | $2,283 |
| 2851 | SS1 | 1230 | 10m InfinBand X4 to X4 optical cable | $1,733 |
| 2851 | SS1 | 1231 | 20m InfiniBand X4 to X4 optical cable | $1,870 |
| 2851 | SS1 | 1232 | 30m InfiniBand X4 to X4 optical cable | $2,008 |
| 2851 | SS1 | 1233 | 50m InfiniBand X4 to X4 optical cable | $2,283 |
| 2851 | SS1 | 9000 | Plant merge into 2851 rack | $0 |
| 2851 | SS1 | 9001 | Field merge into 2851 rack | $0 |
| 2851 | SS1 | 9555 | Bulk order feature | $0 |
| 2851 | SS1 | 9556 | IGF transaction indicator | $0 |
| 2851 | DR1 | Storage Controller | $117,767 | |
| 2851 | DR1 | 1300 | 10-pack of 7.2K RPM 1TB SATA HDDs | $16,868 |
| 2851 | DR1 | 1301 | 10-pack of 7.2K RPM 2TB SATA HDDs | $40,362 |
| 2851 | DR1 | 1310 | 10-pack of 15K RPM 450GB SAS HDDs | $34,855 |
| 2851 | DR1 | 9000 | Plant merge into 2851 rack | $0 |
| 2851 | DR1 | 9001 | Field merge into 2851 rack | $0 |
| 2851 | DR1 | 9011 | Plant install 1st storage controller (EIA positions 1-4) | $0 |
| 2851 | DR1 | 9012 | Plant install 2nd storage controller (EIA positions 9-12) | $0 |
| 2851 | DR1 | 9013 | Plant install 3rd storage controller (EIA positions 21-24) | $0 |
| 2851 | DR1 | 9014 | Plant install 4th storage controller (EIA positions 29-32) | $0 |
| 2851 | DR1 | 9555 | Bulk order feature | $0 |
| 2851 | DR1 | 9556 | IGF transaction indicator | $0 |
| 2851 | DR1 | 9800 | Install in Base Rack | $0 |
| 2851 | DR1 | 9801 | Install in Storage Expansion Rack #1 | $0 |
| 2851 | DR1 | 9802 | Install in Storage Expansion Rack #2 | $0 |
| 2851 | DR1 | 9803 | Install in Storage Expansion Rack #3 | $0 |
| 2851 | DR1 | 9804 | Install in Storage Expansion Rack #4 | $0 |
| 2851 | DR1 | 9805 | Install in Storage Expansion Rack #5 | $0 |
| 2851 | DR1 | 9806 | Install in Storage Expansion Rack #6 | $0 |
| 2851 | DR1 | 9807 | Install in Storage Expansion Rack #7 | $0 |
| 2851 | DR1 | 9808 | Install in Storage Expansion Rack #8 | $0 |
| 2851 | DR1 | 9809 | Install in Storage Expansion Rack #9 | $0 |
| 2851 | DR1 | 9810 | Install in Storage Expansion Rack #10 | $0 |
| 2851 | DR1 | 9811 | Install in Storage Expansion Rack #11 | $0 |
| 2851 | DR1 | 9812 | Install in Storage Expansion Rack #12 | $0 |
| 2851 | DR1 | 9813 | Install in Storage Expansion Rack #13 | $0 |
| 2851 | DR1 | 9814 | Install in Storage Expansion Rack #14 | $0 |
| 2851 | DR1 | 9815 | Install in Storage Expansion Rack #15 | $0 |
| 2851 | DE1 | Disk Storage Expansion unit (DSE) | $47,107 | |
| 2851 | DE1 | 1300 | 10-pack of 7.2K RPM 1TB SATA HDDs | $16,868 |
| 2851 | DE1 | 1301 | 10-pack of 7.2K RPM 2TB SATA HDDs | $40,362 |
| 2851 | DE1 | 1310 | 10-pack of 15K RPM 450GB SAS HDDs | $34,855 |
| 2851 | DE1 | 9000 | Plant merge into 2851 rack | $0 |
| 2851 | DE1 | 9001 | Field merge into 2851 rack | $0 |
| 2851 | DE1 | 9021 | Plant install 1st DES unit (EIA positions 5-8) | $0 |
| 2851 | DE1 | 9022 | Plant install 2nd DES unit (EIA positions 13-16) | $0 |
| 2851 | DE1 | 9023 | Plant install 3rd DES unit (EIA positions 25-28) | $0 |
| 2851 | DE1 | 9024 | Plant install 4th DES unit (EIA positions 33-36) | $0 |
| 2851 | DE1 | 9555 | Bulk order feature | $0 |
| 2851 | DE1 | 9556 | IGF transaction indicator | $0 |
| 2851 | DE1 | 9800 | Install in Base Rack | $0 |
| 2851 | DE1 | 9801 | Install in Storage Expansion Rack #1 | $0 |
| 2851 | DE1 | 9802 | Install in Storage Expansion Rack #2 | $0 |
| 2851 | DE1 | 9803 | Install in Storage Expansion Rack #3 | $0 |
| 2851 | DE1 | 9804 | Install in Storage Expansion Rack #4 | $0 |
| 2851 | DE1 | 9805 | Install in Storage Expansion Rack #5 | $0 |
| 2851 | DE1 | 9806 | Install in Storage Expansion Rack #6 | $0 |
| 2851 | DE1 | 9807 | Install in Storage Expansion Rack #7 | $0 |
| 2851 | DE1 | 9808 | Install in Storage Expansion Rack #8 | $0 |
| 2851 | DE1 | 9809 | Install in Storage Expansion Rack #9 | $0 |
| 2851 | DE1 | 9810 | Install in Storage Expansion Rack #10 | $0 |
| 2851 | DE1 | 9811 | Install in Storage Expansion Rack #11 | $0 |
| 2851 | DE1 | 9812 | Install in Storage Expansion Rack #12 | $0 |
| 2851 | DE1 | 9813 | Install in Storage Expansion Rack #13 | $0 |
| 2851 | DE1 | 9814 | Install in Storage Expansion Rack #14 | $0 |
| 2851 | DE1 | 9815 | Install in Storage Expansion Rack #15 | $0 |
| 2851 | I36 | 36-port InfiniBand Switch | $34,917 | |
| 2851 | I36 | 9000 | Plant merge into 2851 rack | $0 |
| 2851 | I36 | 9001 | Field merge into 2851 rack | $0 |
| 2851 | I36 | 9556 | IGF transaction indicator | $0 |
| 2851 | I96 | 96-port InfiniBand Switch | $134,592 | |
| 2851 | I96 | 1500 | Voltaire sFB-2004 Switch Fabric boards | $20,406 |
| 2851 | I96 | 1501 | Voltaire sLB-2024 24-port 4X DDR InfiniBand Line Board | $47,750 |
| 2851 | I96 | 1502 | Voltaire sMB-HM Hi-memory Management board | $35,719 |
| 2851 | I96 | 1503 | Voltaire sPU power supply | $10,250 |
| 2851 | I96 | 9000 | Plant merge into 2851 rack | $0 |
| 2851 | I96 | 9001 | Field merge into 2851 rack | $0 |
| 2851 | I96 | 9556 | IGF transaction indicator | $0 |
| 2851 | RXA | Base Rack | $28,736 | |
| 2851 | RXA | 0100 | Two 50-port 10/100/1000 Level 2 Ethernet switches | $6,838 |
| 2851 | RXA | 0101 | Service Ladder | $0 |
| 2851 | RXA | 5000 | Plant install interface node | $0 |
| 2851 | RXA | 5001 | Field install interface node (MES) | $0 |
| 2851 | RXA | 5002 | Plant install management node | $0 |
| 2851 | RXA | 5003 | Field install management node (MES) | |
| 2851 | RXA | 5004 | Plant install storage node | $0 |
| 2851 | RXA | 5005 | Field install storage node (MES) | $0 |
| 2851 | RXA | 5006 | Plant install storage controller | $0 |
| 2851 | RXA | 5007 | Field install storage controller (MES) | $0 |
| 2851 | RXA | 5008 | Plant install disk storage expansion unit | $0 |
| 2851 | RXA | 5009 | Field install disk storage expansion unit MES | $0 |
| 2851 | RXA | 5010 | Plant install interface node | $0 |
| 2851 | RXA | 5011 | Plant install 96-port IB switch | $0 |
| 2851 | RXA | 6070 | Standard front and rear doors | $2,109 |
| 2851 | RXA | 6086 | Suite Attach Kit 2m rack | $250 |
| 2851 | RXA | 6098 | Side Panel | $150 |
| 2851 | RXA | 6249 | Acoustic front and rear doors | $7,277 |
| 2851 | RXA | 6858 | Rear Door Heat Exchanger | $7,250 |
| 2851 | RXA | 7188 | Side mount 1-phase PDUs | $2,000 |
| 2851 | RXA | 7192 | Intelligent PDUs | $2,500 |
| 2851 | RXA | 9003 | Config #1, 36-port IB switches, interface nodes only | $0 |
| 2851 | RXA | 9004 | Config #2, 96-port IB switches,interface nodes only | $0 |
| 2851 | RXA | 9005 | Config #,3, 36-port IB switches interface nodes and storage pod | $0 |
| 2851 | RXA | 9854 | Power cord 1-ph, NEMA L6-30 | $0 |
| 2851 | RXA | 9856 | Power cord 1-ph IEC309, P+N+G 32A | $0 |
| 2851 | RXA | 9857 | Power cord 1-ph Aust./New Zealand | $0 |
| 2851 | RXA | 9858 | Power cord 1-ph, 250Vac Korea | $0 |
| 2851 | RXB | Storage expansion rack | $23,108 | |
| 2851 | RXB | 0100 | Two 50-port 10/100/1000 Level 2 Ethernet switches | $6,838 |
| 2851 | RXB | 5004 | Plant install storage node | $0 |
| 2851 | RXB | 5005 | Field install storage node (MES) | $0 |
| 2851 | RXB | 5006 | Plant install storage controller | $0 |
| 2851 | RXB | 5007 | Field install storage controller (MES) | $0 |
| 2851 | RXB | 5008 | Plant install disk storage expansion unit | $0 |
| 2851 | RXB | 5009 | Field install disk storage expansion unit (MES) | $0 |
| 2851 | RXB | 6070 | Standard front and rear doors | $2,109 |
| 2851 | RXB | 6086 | Suite Attach Kit 2m rack | $250 |
| 2851 | RXB | 6098 | Side Panel | $150 |
| 2851 | RXB | 6249 | Acoustic front and rear doors | $7,277 |
| 2851 | RXB | 6858 | Rear Door Heat Exchanger | $7,250 |
| 2851 | RXB | 7188 | Side mount 1-phase PDUs | $2,000 |
| 2851 | RXB | 7192 | Intelligent PDUs | $2,500 |
| 2851 | RXB | 9701 | Storage expansion rack #1 | $0 |
| 2851 | RXB | 9702 | Storage expansion rack #2 | $0 |
| 2851 | RXB | 9703 | Storage expansion rack #3 | $0 |
| 2851 | RXB | 9704 | Storage expansion rack #4 | $0 |
| 2851 | RXB | 9705 | Storage expansion rack #5 | $0 |
| 2851 | RXB | 9706 | Storage expansion rack #6 | $0 |
| 2851 | RXB | 9707 | Storage expansion rack #7 | $0 |
| 2851 | RXB | 9708 | Storage expansion rack #8 | $0 |
| 2851 | RXB | 9709 | Storage expansion rack #9 | $0 |
| 2851 | RXB | 9710 | Storage expansion rack #10 | $0 |
| 2851 | RXB | 9711 | Storage expansion rack #11 | $0 |
| 2851 | RXB | 9712 | Storage expansion rack #12 | $0 |
| 2851 | RXB | 9713 | Storage expansion rack #13 | $0 |
| 2851 | RXB | 9714 | Storage expansion rack #14 | $0 |
| 2851 | RXB | 9715 | Storage expansion rack #15 | $0 |
| 2851 | RXB | 9854 | Power cord 1-ph, NEMA L6-30 | $0 |
| 2851 | RXB | 9856 | Power cord 1-ph IEC309, P+N+G 32A | $0 |
| 2851 | RXB | 9857 | Power cord 1-ph Aust./New Zealand | $0 |
| 2851 | RXB | 9858 | Power cord 1-ph, 250Vac Korea | $0 |
| 2851 | RXC | Interface expansion rack | $23,108 | |
| 2851 | RXC | 0100 | Two 50-port 10/100/1000 Level 2 Ethernet switches | $6,838 |
| 2851 | RXC | 5000 | Plant install interface node | $0 |
| 2851 | RXC | 5001 | Field install interface node (MES) | $0 |
| 2851 | RXC | 6070 | Standard front and rear doors | $2,109 |
| 2851 | RXC | 6086 | Suite Attach Kit 2m rack | $250 |
| 2851 | RXC | 6098 | Side Panel | $150 |
| 2851 | RXC | 6249 | Acoustic front and rear doors | $7,277 |
| 2851 | RXC | 6858 | Rear Door Heat Exchanger | $7,250 |
| 2851 | RXC | 7188 | Side mount 1-phase PDUs | $7,781 |
| 2851 | RXC | 7192 | Intelligent PDUs | $2,500 |
| 2851 | RXC | 9854 | Power cord 1-ph, NEMA L6-30 | $0 |
| 2851 | RXC | 9856 | Power cord 1-ph IEC309, P+N+G 32A | $0 |
| 2851 | RXC | 9857 | Power cord 1-ph Aust./New Zealand | $0 |
| 2851 | RXC | 9858 | Power cord 1-ph, 250Vac Korea | $0 |
Alternative service
| Mach | Feat | IBM | ||||||||||||||
| type | Model | code | Description | list price | ESA MA 24x7x2 (E2H) | ESA MA 24x7x4 (E24) | ESA MA 24x7x4 (E4H) | ESA MA 9x5xnd (E95) | ESA WSU 1yr 24x7x2 (W2H) | ESA WSU 1yr 24x7x4 (W24) | ESA WSU 1yr 9x5x4 (W4H) | SLCC | LEGACY MA 24x7x4 (IOR) | ESA MA 9x5xnd (I08) | LEGACY WSU 1yr 24x7x4 (IOR) | ESA STD |
| 2851 | SI1 | Interface Node | $8,547 | $ 338 | $ 225 | $ 203 | $ 162 | $ 2,100 | $ 756 | $ 486 | 1828 | $ 270 | $ 195 | $ 756 | 24x7 | |
| 2851 | SM1 | Management Node | $9,206 | $ 338 | $ 225 | $ 203 | $ 162 | $ 2,100 | $ 756 | $ 486 | 1828 | $ 270 | $ 195 | $ 756 | 24x7 | |
| 2851 | SS1 | Storage Node | $12,897 | $ 413 | $ 275 | $ 248 | $ 198 | $ 2,800 | $1,000 | $ 594 | 1828 | $ 330 | $ 238 | $ 1,000 | 24x7 | |
| 2851 | DR1 | Storage Controller | $117,767 | $ 750 | $ 500 | $ 450 | $ 360 | $ 4,680 | $1,680 | $ 1,080 | 1828 | $ 600 | $ 432 | $ 1,680 | 24x7 | |
| 2851 | DR1 | 1300 | 10-pack of 7.2K RPM 1TB SATA HDDs | $16,868 | $ 155 | $ 103 | $ 93 | $ 74 | $ 964 | $ 346 | $ 222 | 1828 | $ 124 | $ 89 | $ 346 | 24x7 |
| 2851 | DR1 | 1301 | 10-pack of 7.2K RPM 2TB SATA HDDs | $40,362 | $ 263 | $ 175 | $ 158 | $ 126 | $ 1,638 | $ 588 | $ 378 | 1828 | $ 210 | $ 151 | $ 588 | 24x7 |
| 2851 | DR1 | 1310 | 10-pack of 15K RPM 450GB SAS HDDs | $34,855 | $ 241 | $ 160 | $ 144 | $ 116 | $ 1,500 | $ 539 | $ 345 | 1828 | $ 193 | $ 139 | $ 539 | 24x7 |
| 2851 | DE1 | Disk Storage Expansion unit (DSE) | $47,107 | $ 313 | $ 208 | $ 188 | $ 150 | $ 1,950 | $ 700 | $ 450 | 1828 | $ 250 | $ 180 | $ 700 | 24x7 | |
| 2851 | DE1 | 1300 | 10-pack of 7.2K RPM 1TB SATA HDDs | $16,868 | $ 155 | $ 103 | $ 93 | $ 74 | $ 964 | $ 346 | $ 222 | 1828 | $ 124 | $ 89 | $ 346 | 24x7 |
| 2851 | DE1 | 1301 | 10-pack of 7.2K RPM 2TB SATA HDDs | $40,362 | $ 263 | $ 175 | $ 158 | $ 126 | $ 1,638 | $ 588 | $ 378 | 1828 | $ 210 | $ 151 | $ 588 | 24x7 |
| 2851 | DE1 | 1310 | 10-pack of 15K RPM 450GB SAS HDDs | $34,855 | $ 241 | $ 160 | $ 144 | $ 116 | $ 1,500 | $ 539 | $ 345 | 1828 | $ 193 | $ 139 | $ 539 | 24x7 |
| 2851 | I36 | 36-port InfiniBand Switch | $34,917 | $ 313 | $ 208 | $ 188 | $ 150 | $ 1,950 | $ 700 | $ 450 | 1828 | $ 250 | $ 180 | $ 700 | 24x7 | |
| 2851 | I96 | 96-port InfiniBand Switch | $134,592 | $1,125 | $ 750 | $ 675 | $ 540 | $ 7,000 | $2,520 | $ 1,620 | 1828 | $ 900 | $ 648 | $ 2,520 | 24x7 | |
| 2851 | RXA | Base Rack | $28,736 | $ 250 | $ 167 | $ 150 | $ 120 | $ 1,560 | $ 560 | $ 360 | 1828 | $ 200 | $ 144 | $ 560 | 24x7 | |
| 2851 | RXB | Storage expansion rack | $23,108 | $ 219 | $ 146 | $ 131 | $ 105 | $ 1,365 | $ 490 | $ 315 | 1828 | $ 175 | $ 126 | $ 490 | 24x7 | |
| 2851 | RXC | Interface expansion rack | $23,108 | $ 219 | $ 146 | $ 131 | $ 105 | $ 1,365 | $ 490 | $ 315 | 1828 | $ 175 | $ 126 | $ 490 | 24x7 |
ServicePac prices
For ServiceElect (ESA) maintenance service charges, contact IBM Global Services at 888-IBM-4343 (426-4343).
IBM Global Financing
IBM Global Financing offers competitive financing to credit-qualified customers to assist them in acquiring IT solutions. Offerings include financing for IT acquisition, including hardware, software, and services, from both IBM and other manufacturers or vendors. Offerings (for all customer segments: small, medium, and large enterprise), rates, terms, and availability can vary by country. Contact your local IBM Global Financing organization or visit
IBM Global Financing offerings are provided through IBM Credit LLC in the United States, and other IBM subsidiaries and divisions worldwide to qualified commercial and government customers. Rates are based on a customer's credit rating, financing terms, offering type, equipment type, and options, and may vary by country. Other restrictions may apply. Rates and offerings are subject to change, extension, or withdrawal without notice.
IBM Global Financing offers competitive financing to credit-qualified customers and IBM Business Partners to assist them in acquiring IT solutions. Our offerings include financing for IT acquisition, including hardware, software, and services, from both IBM and other manufacturers or vendors, as well as commercial financing (revolving lines of credit, term loans, acquisition facilities, and inventory financing credit lines) for Business Partners. Offerings (for all customer segments: small, medium, and large enterprise), rates, terms, and availability can vary by country. Contact your local IBM Global Financing organization or visit the Web site:
IBM Global Financing offerings are provided through IBM Credit LLC in the United States, and other IBM subsidiaries and divisions worldwide to qualified commercial and government customers. Rates are based on a customer's credit rating, financing terms, offering type, equipment type, and options, and may vary by country. Other restrictions may apply. Rates and offerings are subject to change, extension, or withdrawal without notice. Financing solutions from IBM Global Financing.
|
|
| Order now |
To order, contact the Americas Call Centers or your local IBM representative, or your IBM Business Partner.
To identify your local IBM representative or IBM Business Partner, call 800-IBM-4YOU (426-4968).
Phone: 800-IBM-CALL (426-2255)
Fax: 800-2IBM-FAX (242-6329)
Internet: callserv@ca.ibm.com
Mail: IBM Teleweb Customer Support
ibm.com® Sales Execution Center, Americas North
3500 Steeles Ave. East, Tower 3/4
Markham, Ontario
Canada
L3R 2Z1
Reference: SE001
The Americas Call Centers, our national direct marketing organization, can add your name to the mailing list for catalogs of IBM products.
Note: Shipments will begin after the planned availability date.
Trademarks
System Storage and Electronic Service Agent are trademarks of IBM Corporation in the United States, other countries, or both.
IBM, z/OS, Tivoli and ibm.com are registered trademarks of IBM Corporation in the United States, other countries, or both.
Microsoft is a registered trademark of Microsoft Corporation in the United States, other countries, or both.
Intel and Xeon are registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries.
Adobe is a registered trademark of Adobe Systems Incorporated in the United States, and/or other countries.
Other company, product, and service names may be trademarks or service marks of others.
Terms of use
IBM products and services which are announced and available in your country can be ordered under the applicable standard agreements, terms, conditions, and prices in effect at the time. IBM reserves the right to modify or withdraw this announcement at any time without notice. This announcement is provided for your information only. Additional terms of use are located at:
For the most current information regarding IBM products, consult your IBM representative or reseller, or visit the IBM worldwide contacts page
