Feedback


Family 9125+01 IBM Power 575 (9125-F2A) POWER6 Supercomputing Node

IBM United States Sales Manual
Revised:  April 08, 2014.

Table of contents
TOC Link Product life cycle dates TOC Link Technical description
TOC Link Abstract TOC Link Publications
TOC Link Highlights TOC Link Features
TOC Link Description TOC Link Accessories
TOC Link Product positioning TOC Link Machine elements
TOC Link Models TOC Link Supplies

 
Product life cycle dates
Type Model Announced Available Marketing Withdrawn Service Discontinued
9125-F2A 2008/04/082008/05/06 2010/07/30 -

Back to topBack to top
 
Abstract

The IBM 9125 Power 575 delivers a 32-core, 4.7 GHz POWER6 high-bandwidth supercomputing node, ideal for many high-performance computing applications.

Model abstract 9125-F2A

The IBM 9125 Power 575 Model F2A has a 4.7 GHz dual-core POWER6 processor in a 32-core configuration, 2U, 24-inch rack-mounted, water-cooled node design, 32 MB of L3 cache and 8 MB of L2 cache per microprocessor dual-core chip, up to 256 GB of DDR2 memory per node, and up to 5093 GB of internal disk storage.
Back to topBack to top
 

Highlights

The Power 575 with POWER6 processor-based technology delivers the next-generation supercomputing node with:

  • 4.7 GHz dual-core POWER6 processors in a 32-core configuration
  • 2U, 24-inch rack-mounted, water-cooled node design
  • 32 MB of L3 cache and 8 MB of L2 cache per microprocessor dual-core chip
  • Up to 256 GB of DDR2 memory per node
  • Up to 5093 GB of internal disk storage
  • Up to 16 hot-swap SCSI disk bays and 20 hot-swap PCI-X slots
  • Up to 28 hot-swap SAS SFF disk bays and 24 hot-swap PCIe slots
  • Redundant Bulk Power Regulators
  • Dynamic logical partitioning (DLPAR)
  • Optional PowerVM Virtualization
  • SAS disk drawer expansion
  • Fast support via Electronic Service Agent(TM) round-the-clock error reporting

Back to topBack to top
 
Description

The Power 575 is packaged in a superdense 2U form factor with up to 14 nodes installed in a 42U-tall, 24-inch water-cooled rack. Multiple racks of 575 nodes can be combined to provide a broad range of powerful cluster solutions.

The symmetric multiprocessor (SMP) node uses innovative, 64-bit, dual-core POWER6 microprocessors in a 4.7 GHz 32-core configuration. Each microprocessor dual-core chip is supported by 32 MB of Level 3 cache, 8 MB of L2 cache, and up to four DDR2 memory DIMMs. Each 32-core node includes 64 slots for memory DIMMs. Memory sizes range from 32 GB up to 256 GB. With the optional I/O assembly with PCI and I/O drawer attachment, along with an I/O drawer, up to 24 PCI cards and up to 28 disk drives per node are available.

Other features include:

  • One integrated SAS controller for internal disk
  • Integrated service processor
  • Two integrated dual-ported 10/100/1000 Mbps Ethernet ports
  • Optional Dual 10 Gb Optical Ethernet-SR Transceivers
  • Optional PowerVM Virtualization
  • Optional dual 2-port 4x Host Channel Adapter
  • Integrated SAS connector for SAS Disk Drawer connection
  • SAS disk drawer expansion

The 575 supports the AIX and Linux operating systems. These operating systems can run simultaneously in different partitions within the 575 node.

IBM Electronic Service Agent ("call home") is integrated within the Hardware Management Console (HMC), and should be activated for automated hardware support for all systems in the environment. IBM representatives can enable the Electronic Service Agent free of charge for clients who purchase the Power 575.

The Power 575 delivers an innovative, elegant conceptual design and stylish packaging. Mounted in a sleek 2U enclosure, the modular 575 enables you to deploy up to 14 water-cooled nodes in a single, 24-inch system frame.

The heart of the supercomputing node contains 32 POWER6 processors on 16 dual-core microprocessor chips. Each microprocessor dual-core chip is supported by 32 MB of L3 cache, 8 MB of L2 cache, and up to four DDR2 memory DIMMs. Each 32-core node includes 64 slots for memory.

To increase the rack density of the Power 575 supercomputing node, the microprocessors are cooled with an innovative modular water cooling design and distribution system. Included in the system-side water-cooling loop is an integrated rear door heat exchanger that significantly reduces the heat load to air from the system.

At the back of the node enclosure, selectable I/O assemblies deliver two small form factor disk bays, two integrated dual ported 10/100/1000 Mbps Ethernet ports, optional 10 Gb optical Ethernet, and optional 12X ports for attaching an I/O expansion drawer. Up to two of the optional dual 2-port 4x host channel adapters are available for the high-performance interconnect.

The Power 575 supports both the AIX and Linux operating systems. These operating systems can run simultaneously in different partitions within the 575 node.

Accessibility by people with disabilities

A U.S. Section 508 Voluntary Product Accessibility Template (VPAT) containing details on accessibility compliance can be requested at:

http://www.ibm.com/able/product_accessibility/index.html

Section 508 of the US Rehabilitation Act

The IBM Power 575 Server is capable as of May 6, 2008, when used in accordance with IBM's associated documentation, of minimally satisfying the applicable requirements of Section 508 of the Rehabilitation Act, provided the user attaches another system that contains the assistive technology necessary to interact through a command-line interface.
Back to topBack to top
 

Product positioning

The Power 575 is a substantially enhanced POWER6 follow-on to the p5-575 POWER5+ cluster node. Like the p5-575, the 575 is an extremely effective solution to the requirements of the most demanding, memory bandwidth-intensive high-performance computing applications.
Back to topBack to top
 

Models

Model summary matrix

Model Processor Cache Memory Per Node Internal Disk Storage
F2A 4.7 GHz dual-core POWER6 32 MB of L3 and 8 MB of L2 per miroprocessor dual-core chip Up to 256 GB of DDR2 Up to 5093 GB

Customer setup (CSU)

No.

Devices supported

The following external machine types are supported on the indicated models for MT 9125.

This list is not all inclusive. Many devices are supported through standard ports. Please refer to the sales manual of the external machine type and the list of supported devices in the appropriate section of the AIX sales manual for further attach support information.

         |F|  X = SUPPORTED DEVICE
         |2|
         |A|
  MT-MOD | |        DESCRIPTION
---------|-|---------------------------------------------------------
---------+-+--------Communications-----------------------------------
- - - - -|-|- - - - - - - - - - - - - - - - - - - - - - - - - - - - -
7036-P16 |X| IBM 7036-P16
         | |
---------+-+--------Disk---------------------------------------------
- - - - -|-|- - - - - - - - - - - - - - - - - - - - - - - - - - - - -
1710-10U |X| IBM System Storage EXP100 Expansion Unit
1722-60U |X| IBM System Storage DS4300 Disk System
1722-6LU |X| IBM System Storage DS4300 Disk System
1724-100 |X| IBM System Storage DS4100 Disk System
1740-710 |X| IBM System Storage EXP710 Expansion Unit
1742-1RU |X| IBM 1742-1RU
1742-90U |X| IBM System Storage DS4500 Disk System
1750-522 |X| IBM 1750-522
1812-81A |X| IBM System Storage DS4000 EXP810 Storage Expansion Unit
         | |Model 81
1812-81S |X| IBM System Storage DS4000 EXP810 Expansion Unit Model
         | |81-DC
1812-8VA |X| IBM System Storage DS4000 EXP420 Storage Expansion Unit
1814-70A |X| IBM System Storage DS4700 Express Model 70
1814-70S |X| IBM System Storage DS4700 Express Model 70-DC
1814-72A |X| IBM System Storage DS4700 Express Model 72
1814-72S |X| IBM System Storage DS4700 Express Model 72-DC
1814-7VA |X| IBM System Storage DS4200 Express Model 7V
1815-80A |X| IBM System Storage DS4800 Model 80A
1815-82A |X| IBM System Storage DS4800 Model 82A
1815-84A |X| IBM System Storage DS4800 Model 84A
1815-88A |X| IBM System Storage DS4800 Model 88A
1818-51A |X| IBM 1818-51A (DS5100)
1818-53A |X| IBM 1818-53A (DS5300)
1818-D1A |X| IBM 1818-D1A (EXP5000)
2076-112 |X| The IBM 2076 Storwize V7000 Control Enclosure 112
2076-124 |X| The IBM 2076 Storwize V7000 Control Enclosure 124
2076-212 |X| The IBM 2076 Storwize V7000 Control Enclosure 212
2076-224 |X| The IBM 2076 Storwize V7000 Control Enclosure 224
2105-800 |X| IBM 2105-800
2107-921 |X| IBM 2107-921
2107-922 |X| IBM 2107-922
2107-931 |X| IBM 2107-931
2107-932 |X| IBM 2107-932
2107-9A2 |X| IBM 2107-9A2
2107-9B2 |X| IBM 2107-9B2
2421-941 |X| IBM 2421-941 (DS8700)
2421-94E |X| IBM 2421-94E (DS8700)
 
2422-941 |X| IBM 2422-941 (DS8700)
2422-94E |X| IBM 2422-94E (DS8700)
 
2423-941 |X| IBM 2423-941 (DS8700)
2423-94E |X| IBM 2423-94E (DS8700)
 
2424-941 |X| IBM 2424-941 (DS8700)
2424-94E |X| IBM 2424-94E (DS8700)
2810-A14 |X| IBM XIV Disk Storage Unit
7031-D24 |X| IBM TotalStorage EXP24 7031-D24
7031-T24 |X| IBM TotalStorage EXP24 7031-T24
7204-646 |X| IBM 7204-646
         | |
---------+-+--------Displays-----------------------------------------
- - - - -|-|- - - - - - - - - - - - - - - - - - - - - - - - - - - - -
7042-C06 |X| IBM 7042-C06
7042-C07 |X| IBM 7042-C07
7042-CR4 |X| IBM 7042-CR4
7310-C03 |X| IBM 7310-C03
7310-C04 |X| IBM 7310-C04
7310-C05 |X| IBM 7310-C05
7310-C06 |X| IBM 7310-C06
7310-CR2 |X| IBM 7310-CR2
7310-CR3 |X| IBM 7310-CR3
7310-CR4 |X| IBM 7310-CR4
7316-TF1 |X| IBM 7316-TF1
7316-TF3 |X| IBM 7316-TF3
9419-HB7 |X| IBM ThinkVision L191p 19-inch LCD Flat-panel Monitor
9513-AW1 |X| IBM T55A 15.0-inch Color TFT LCD Monitor
9516-B03 |X| IBM MultiMode 16.1-inch TFT LCD Flat Panel Monitor Model
         | |B03
9516-B04 |X| IBM MultiMode 16.1-inch TFT LCD Flat Panel Monitor Model
         | |B04
         | |
---------+-+--------Expansion Cabinets-------------------------------
- - - - -|-|- - - - - - - - - - - - - - - - - - - - - - - - - - - - -
7014-T00 |X| IBM 7014-T00
7014-T42 |X| IBM 7014-T42
7311-D11 |X| IBM 7311-D11
7311-D20 |X| IBM 7311-D20
7314-G30 |X| IBM 7314-G30
         | |
---------+-+--------SCSI Devices-------------------------------------
- - - - -|-|- - - - - - - - - - - - - - - - - - - - - - - - - - - - -
3996-032 |X|
3996-080 |X|
3996-174 |X|
7210-025 |X| IBM 7210-025
7210-030 |X| IBM 7210-030
         | |
---------+-+--------Services-----------------------------------------
- - - - -|-|- - - - - - - - - - - - - - - - - - - - - - - - - - - - -
0463-001 |X| Software Customization (CCS)
0463-002 |X| CCS Customization Services
         | |
---------+-+--------Storage Network Devices--------------------------
- - - - -|-|- - - - - - - - - - - - - - - - - - - - - - - - - - - - -
1750-EX2 |X| IBM System Storage DS6000 Expansion Unit
1814-20A |X| IBM System Storage (DS5020) Model 20A
1814-20H |X| SYSTEM STORAGE DS5020
1814-24H |X| SYSTEM STORAGE DS5020
1814-28H |X| SYSTEM STORAGE DS5020
1814-52A |X| IBM System Storage (DS5020) Model 52A
2105-750 |X| IBM 2105-750
2145-4F2 |X| IBM 2145-4F2
2145-8F2 |X| IBM 2145-8F2
2145-8F4 |X| IBM 2145-8F4
2421-931 |X| SYSTEM STORAGE DS8100
2421-932 |X| SYSTEM STORAGE DS8300
2421-9B2 |X| SYSTEM STORAGE DS8300
2422-931 |X| SYSTEM STORAGE DS8100
2422-932 |X| SYSTEM STORAGE DS8300
2422-9B2 |X| SYSTEM STORAGE DS8300
2423-931 |X| SYSTEM STORAGE DS8100
2423-932 |X| SYSTEM STORAGE DS8300
2423-9B2 |X| SYSTEM STORAGE DS8300
2424-931 |X| SYSTEM STORAGE DS8100
2424-932 |X| SYSTEM STORAGE DS8300
2424-9B2 |X| SYSTEM STORAGE DS8300
2861-001 |X| IBM System Storage EXN1000 SATA expansion unit
2863-001 |X| IBM System Storage EXN2000
2863-A10 |X| IBM System Storage N3700 Model A10
2863-A20 |X| IBM System Storage N3700 Model A20
2864-A10 |X| IBM System Storage N5200 Model A10
2864-A20 |X| IBM System Storage N5200 Model A20
2865-A10 |X| IBM System Storage N5500 Model A10
2865-A20 |X| IBM System Storage N5500 Model A20
2866-A10 |X|
2866-A20 |X| IBM System Storage N7600 Model A20
2867-A10 |X| IBM System Storage N7800 Model A10
2867-A20 |X| IBM System Storage N7800 Model A20
3958-AP1 |X| IBM 3958-AP1
3958-DD1 |X| IBM 3958-DD1
3958-DD3 |X| IBM 3958-DD3
         | |
---------+-+--------Switch-------------------------------------------
- - - - -|-|- - - - - - - - - - - - - - - - - - - - - - - - - - - - -
2005-B16 |X| IBM TotalStorage SAN16B-2
2005-B32 |X| IBM TotalStorage SAN32B-2 Express Model
2005-B5K |X| IBM System Storage SAN32B-3
2005-B64 |X| IBM System Storage SAN64B-2 Fabric Switch
2005-H08 |X| IBM TotalStorage SAN Switch H16
2005-H16 |X| IBM TotalStorage SAN Switch H16
2026-224 |X| IBM TotalStorage SAN24M-1
2026-416 |X| IBM TotalStorage SAN16M-2
2026-432 |X| IBM TotalStorage SAN32M-2
2026-E12 |X| IBM TotalStorage SAN12M-1
2027-140 |X| IBM TotalStorage SAN140M
2027-232 |X| IBM TotalStorage SAN32M-1
2027-256 |X| IBM TotalStorage SAN256M
2031-216 |X| IBM 2031-216
2031-232 |X| IBM 2031-232
2032-064 |X| IBM 2032-064
2032-140 |X| IBM 2032-140
2034-212 |X| IBM 2034-212
2053-424 |X| Cisco MDS 9124 for IBM System Storage switch
2053-434 |X| Cisco MDS 9134 for IBM System Storage switch
2053-S34 |X| Cisco MDS 9134 for IBM System Storage switch
2061-020 |X| IBM 2061-020
2061-040 |X| IBM 2061-040
2062-D01 |X| IBM 2062-D01
2062-D04 |X| Cisco MDS 9506 MultilaIayer Director
2062-D07 |X| Cisco MDS 9509 MultilaIayer Director
2062-D1A |X| Cisco MDS 9216A Multilayer Fabric Switch
2062-D1H |X| Cisco MDS 9216i Multilayer Fabric Switch
2062-E11 |X| Cisco MDS 9513 Multilayer Director
2062-T04 |X| Cisco MDS 9506 Multilayer Director
2062-T07 |X| Cisco MDS 9509 MultilaIayer Director
2109-M14 |X| IBM 2109-M14
2109-M48 |X| IBM TotalStorage SAN256B
         | |
---------+-+--------Tape---------------------------------------------
- - - - -|-|- - - - - - - - - - - - - - - - - - - - - - - - - - - - -
3494-D22 |X| IBM 3494-D22
3494-D24 |X| IBM 3494-D24
3494-L22 |X| IBM 3494-L22
3573-L2U |X| TS3100 Tape Library Model L2U
3573-L4U |X| TS3200 Tape Library Model L4U
3576-E9U |X|
3576-L5B |X|
3577-L5U |X| IBM 3577-L5U
3580-H3L |X| System Storage TS2230 Tape Drive Model H3L
3580-H3S |X| System Storage TS2230 Tape Drive Model H3S
3580-H4S |X| System Storage TS2240 Tape Drive Model H4S
3580-L23 |X| IBM 3580-L23
3580-L33 |X| TotalStorage 3580 Tape Drive Model L33
3580-L43 |X| System Storage TS2340 Tape Drive Model L43
3580-S43 |X| System Storage TS2340 Tape Drive Model S43
3581-F28 |X| IBM 3581-F28
3581-F38 |X| IBM 3581-F38
3581-L23 |X| IBM 3581-L23
3581-L28 |X| IBM 3581-L28
3581-L38 |X| IBM 3581-L38
3582-L23 |X| IBM 3582-L23
3583-L18 |X| IBM 3583-L18
3583-L36 |X| IBM 3583-L36
3583-L72 |X| IBM 3583-L72
3584-D22 |X| IBM 3584-D22
3584-D23 |X| IBM 3584-D23
3584-D32 |X| IBM 3584-D32
3584-D42 |X| IBM 3584-D42
3584-D52 |X| IBM 3584-D52
3584-D53 |X| IBM 3584-D53
3584-HA1 |X| IBM 3584-HA1
3584-L22 |X| IBM 3584-L22
3584-L23 |X| IBM 3584-L23
3584-L32 |X| IBM 3584-L32
3584-L52 |X| IBM 3584-L52
3584-L53 |X| IBM 3584-L53
3588-F3A |X| IBM 3588-F3A
3588-F3B |X| IBM 3588-F3B
3588-F4A |X| IBM System Storage TS1040 Tape Drive Model F4A
3590-H11 |X| IBM 3590-H11
3590-H1A |X| IBM 3590-H1A
3592-E05 |X| IBM System Storage TS1120 Tape Drive
3592-J1A |X| IBM TotalStorage Enterprise Tape Drive 3592
3952-F05 |X| IBM System Storage 3952 Tape Frame
3954-CV5 |X| IBM Virtualization Engine TS7510
3955-SV5 |X| IBM Virtualization Engine TS7510 Model SV5
3955-SX5 |X| IBM Virtualization Engine TS7510 Model SX5
7205-550 |X| IBM 7205-550
7206-336 |X| IBM 7206-336
7206-VX2 |X| IBM 7206-VX2
7206-VX3 |X| IBM 7206-VX3
7207-122 |X| IBM 7207-122
7207-330 |X| IBM 7207-330
7212-102 |X| IBM 7212-102
7212-103 |X| IBM 7212-103
7212-312 |X| IBM 7212-312
 

Model conversions

Not available.
Back to topBack to top
 

Technical description
TOC Link Physical specifications TOC Link Operating environment TOC Link Limitations
TOC Link Hardware requirements TOC Link Software requirements


Physical specifications

  • Width: 750 mm (29.5 in)
  • Depth: 1524 mm (60 in)
  • Height: 2013 mm (79.5 in)
  • Weight: 1656 kg (3650 lb)

To assure installability and serviceability in non-IBM industry standard racks, review the installation planning information for any product-specific installation requirements.

Operating environment

  • Temperature: 10 to 28 degrees C (50 to 82.4 degrees F)

  • Relative humidity: Noncondensing 20 to 80%

  • Maximum dew point: 17 degrees C (62.6 F)

  • Noise level: typical rack configuration

  • Declared A-weighted sound power level per ISO 9296: 8.2 bels/8.7 bels (Acoustical doors/Slimline doors)

  • Declared A-weighted one-meter sound pressure level per ISO 9296: 65 dB/70 dB, (Acoustical doors/Slimline doors)

Power requirements

  • Operating voltage (3-phase V ac at 50/60 Hz): 200 to 240 V; 380 to 415 V; 480 V
  • Rated current (A per phase): 80 A; 40 A; 32 A

Limitations

IBM Power (9125-F2A):

The 575 consists of the following major components:

  • A 2U-tall processor node housing the system backplane, power supply, cooling components (blowers and water-cooled coldplates and manifolds), and system electronic components. A 0/32 core POWER6 processor with 32 processor activations and 64 DDR2 memory DIMM slots are on the system backplane.

  • Selectable I/O assemblies: One assembly has PCI and I/O drawer attachment capability (#6399), and one does not have PCI capability (#6319). Both I/O assemblies have two integrated dual ported 10/100/1000 Mbps Ethernet ports per node and two small form factor disk bays.

  • The I/O assembly with PCI capability supports up to two I/O riser features.

  • Up to one 12X attached I/O drawer can connect to the I/O assembly (#6399). Available 12X I/O drawers are #5798 containing 20 PCI-X slots and 16 hot-swap SCSI disk bays, #5803 containing 20 PCIe slots and 26 hot-swap SAS SFF disk bays, or #5873 containing 20 PCIe slots and no hot-swap disk bays. A 575 may be connected to one half of an I/O drawer in dual-loop mode. The second half of an I/O drawer may be connected to another 575 node. Attached I/O drawers must be in the same rack as the node.

  • A 42U-tall, 24-inch System Rack with base power (#5770) ordered on the first 575 (9125-F2A) node in the system.

  • The power subsystem is housed in the top 10U of the rack.

Processor Node:

  • The 575 processor node is a 2U-tall, water-cooled, 24-inch rack mounted device. It houses the system processors, memory, system support processor, power supply, blowers, water cooling hardware, and selectable I/O assemblies with disk bays and (HMC) connectivity.

Memory:

  • The 575 uses DDR2 memory DIMMs. All memory must be fully activated with the corresponding quantity of 1 GB memory activation features.

  • Supported DDR2 memory configurations on the 575 are as follows:
          Feature
          number  Description               Quantity    Total memory
          ------- ------------------------  --------    ------------
           5687   0/4 GB (4 x 1 GB) DIMMs        8          32 GB
           5687   0/4 GB (4 x 1 GB) DIMMs       16          64 GB
           5688   0/8 GB (4 x 2 GB) DIMMs        8          64 GB
           5688   0/8 GB (4 x 2 GB) DIMMs       16         128 GB
           5698   0/16 GB (4 x 4 GB) DIMMs       8         128 GB
           5698   0/16 GB (4 x 4 GB) DIMMs      16         256 GB
 

Racks, power, and cooling:

  • The System Rack with base power (#5770) is a 24-inch rack with an integrated power subsystem to support the 575 nodes. It provides 42U of rack space and houses the nodes, the water cooling option, I/O drawers, and the power subsystem.

  • The water cooling option (#6872) includes the modular water units, system side supply and return water manifolds, and associated hoses.

  • The System Rack with base power (#5770) must have door assemblies. Doors kits containing front and rear doors are available in either slim line or acoustic styles. The door kits include a rear door with an integrated rear door heat exchanger. The integrated rear door heat exchanger is on the system side cooling loop.

    • The Slim Line Door Kit provides a minimized footprint for use where conservation of space is desired.

    • The Acoustic Door Kit provides additional acoustic dampening for use where a quieter environment is desired.

  • The height of the System Rack with base power (#5770) may require special handling when shipping by air or when moving under a low doorway. The Compact Handling Option (#7960) is available if deemed required during the review of the Solution Assurance Discussion Guide.

  • The System Rack with base power (#5770) utilizes redundant bulk power regulators in its design. The power subsystem provides redundant 350 V dc power to the 575 nodes and I/O drawers. These bulk power assemblies are mounted in front and rear positions and occupy the top 10U of the rack. The feature 5770 includes the system rack, the two bulk power controller assemblies, the first two bulk power regulators, and the bulk power Ethernet hubs.

  • Power and Ethernet cable features connect to the dc power converters to the bulk power assembly and to the Ethernet hubs in the System Rack. These cable groups contain two UPICs (universal power input cables) and two Ethernet cables.

  • The initial order racking sequence has the water cooling option (#6872) in the bottom 4U, followed by any I/O drawer features in the configuration, with the 575 nodes placed above any I/O drawers.

  • Bulk Power Regulators (#6333) interface to the bulk power assemblies to help ensure proper power is supplied to the system components. Bulk Power Regulators are always installed in pairs in the front and rear bulk power assemblies to provide redundancy. The number of Bulk Power Regulators required is configuration-dependent based on the number of 575 nodes and I/O drawers installed. Two bulk power regulators are included in the System Rack with base power (#5770). Additional bulk power regulators are ordered as feature 6333.

  • Up to four line cords are required per System Rack with base power (#5770), and these line cords must be identical features. Utilize the Solution Assurance Discussion Guide for an in depth understanding of power input line cord redundancy.

  • The 575 is capable of operating voltages (3-phase V ac at 50/60 Hz) of 200 to 240 V, 380 to 415 V, or 480 V.

  • Up to four optional Bulk Power Distribution Assemblies (#6328) are required for system racks with a maximum configuration.

  • Bulk Power Regulators (total) and Line cords
                       Number of 575 nodes
 
             1   2   3   4   5   6   7   8   9  10  11  12  13  14
            ------------------------------------------------------
Number
of       0   2   4   6   6   8  10  10  12  12  12  12  12  12  12
 
I/O      1   2   4   6   8   8  10  12  12  12  12  12  12
Drawers
         2       4   6   8   8  10  12  12  12  12
 
         3           6   8   8  10  12  12
 
         4               8  10  10
 

Note: (1) Two or four linecords are allowed in systems with 6 BPRs or less. Four linecords are required in systems with more than 6 BPRs.

Note: (1) Two or four linecords are allowed in systems with 6 BPRs or less. Four linecords are required in systems with more than 6 BPRs.

Logical partitioning:

  • Logical partitioning (LPAR) allows the 575 node resources to be allocated and for multiple instances of the supported operating systems to be run simultaneously on a single node.

  • LPAR allocation, monitoring, and control is provided by the HMC.

  • Each LPAR functions under its own instance of the operating system.

Optional PowerVM Virtualization and Partition Load Manager:

  • PowerVM Virtualization allows partitions to be created that are in units of less than one CPU (sub-CPU LPARs) and allows the same system I/O to be virtually allocated to these partitions.

  • With PowerVM Virtualization, the processors on the system can be partitioned into as many as 10 LPARs per processor.

  • Optional PowerVM Virtualization includes Partition Load Manager, which will provide cross-partition workload management across the system LPARs.

  • An encrypted key is supplied to the customer and installed on the system, authorizing the partitioning at the subprocessor level.

  • Using PowerVM Virtualization, the 575 can be divided into as many as 254 LPARs. System resources can be dedicated to each LPAR.

System control:

  • Each 575 node can be connected to an HMC for system control, LPAR, and service functions. The HMC is capable of supporting multiple POWER6 nodes.

  • Each 575 node can be connected to two HMCs for redundancy, if desired.

  • Each 575 connects to the integrated Ethernet hubs within the System Rack (#5770). The hubs are connected to the HMC through two Ethernet Cable, HMC Attaches (#7801 or #7802).

I/O drawers:

  • The 575 utilizes optional 4U-tall I/O drawers (#5798, #5803 or #5873) for additional directly attached PCI adapters and disk capabilities.

  • Each I/O drawer can be divided into halves to be shared between two nodes. Each half of #5798 contains 10 blind-swap PCI-X slots and 8 SCSI hot-swap disk bays. Each half of a #5803 contains 10 blind-swap PCIe slots and 13 SAS SFF hot swap disk bays. Each half of a #5873 contains 10 blind-swap PCIe slots and no disk bays.

  • All 10 PCI-X slots on each #5798 I/O drawer planar are capable of supporting either 64-bit or 32-bit PCI or PCI-X adapters. Each #5798 I/O drawer planar provides 10 PCI-X slots capable of supporting 3.3 V signaling PCI or PCI-X adapters operating at speeds up to 133 MHz.

  • Each #5798 I/O drawer planar incorporates two integrated Ultra3 SCSI adapters for direct attachment of the two 4-pack hot-swap backplanes in that half of the drawer. These adapters do not support external SCSI device attachments.

  • Any SAS SFF disk in the #5803 I/O drawer are driven by at least one PCIe SAS adapter and at least one SAS AT cable.

    For the condition where the #5803 is a Shared I/O Drawer, any SAS AT cables required for the entire drawer are to be ordered on the first node of the shared node pair. The first node of the shared pair would also be the same node that has the #5803.

I/O drawer attachment:

  • A system I/O drawer will always be connected to the model 575 CEC via the 575 I/O assembly (#6399). Drawer connections are always made in loops to help protect against a single point-of-failure resulting from an open, missing, or disconnected cable. Systems with non-looped configurations could experience degraded performance and serviceability.

  • I/O drawers are connected to the CEC in either single-loop or dual-loop mode. Dual-loop mode is recommended whenever possible as it will provide the maximum bandwidth between the I/O drawer and the CEC.

  • Single-loop mode connects an entire I/O drawer to the CEC via one 12X loop (two ports). The two I/O planars in the I/O drawer are connected together via a short 12X cable (#1829 for #5798, and #1861 for #5803 and for #5873). Single-loop connection requires one loop (two ports) per I/O drawer. Node to drawer connections for the #5803 and #5873 I/O drawers require the 12X DDR Cables (#1862 or #1863).

  • Dual-loop mode connects a single I/O planar in the drawer to the CEC.

Disks, boot devices, and media devices:

  • A minimum of two identical internal small form factor SAS hard disk drives are required per 575 node. It is highly recommended that these disks be used as mirrored boot devices. This configuration will provide service personnel the maximum amount of diagnostic information if the system encounters errors in the boot sequence.

  • SAS disk expansion drawers (#5886) are available and support up to 12 SAS hot-swap disk per expansion drawer. The integrated SAS connector in the I/O assembly is for SAS disk expansion drawer connection. The integrated SAS connector supports up to two SAS disk expansion drawers.

Hardware requirements

Minimum system configuration: The minimum configuration for a 575 (9125-F2A) includes the following items (for the first node in a rack). Features identified with an "*" allow alternate features to be selected for minimum configuration requirements.

  • 1X - Power 575 (9125-F2A)

  • 1X - 0/32 Core 4.7 GHz POWER6 CPU (#7298)

  • 32X - One CPU activation for #7298 (#7299)

  • 1X - I/O Assembly without PCI capability (#6319) *

  • 1X - Power and Ethernet cables EIA 05 (#6338) *

  • 8X - 0/4 GB DDR2 Memory (4 x 1.0 GB) DIMMs (#5687) *

  • 32X - Activation of 1 GB DDR2 POWER6 Memory (#5680) *

  • 2X - 73 GB 10K RPM SAS SFF Disk Drive (#1881) *

  • 1X - Language specify (#93XX) *

  • 1X - Primary Operating System Indicator for AIX (#2146) or for Linux (#2147)

  • 1X - System Rack with base power (#5770)

  • 1X - Rack Content Specify 9125-F2A (#0271)

  • 1X - Water cooling option (#6872)

  • 1X - Slim Doors with integrated rear door heat exchanger (#6874) *

  • 1X - Ethernet Cable, 6M, HMC to System (#7801) *

  • 2X - Line Cord, 4AWG, 14 ft, 100A Plug (#8696) *

Hardware Management Console (HMC) Machine Code

If attaching an HMC to a new server or adding function to an existing server that requires a firmware update, the HMC machine code may need to be updated.

To determine the HMC machine code level required for the firmware level on any server, go to the following URL to access the Fix Level Recommendation Tool (FLRT) on or after the Planned Availability Date for this product. FLRT will identify the correct HMC machine code for the selected system firmware level.

http://www14.software.ibm.com/webapp/set2/flrt/home

If a single HMC is attached to multiple servers, the HMC machine code level must be updated to the server with the most recent firmware level. All prior levels of server firmware are supported with the latest HMC machine code level.

Software requirements

If installing the AIX operating system:

  • AIX 5L for POWER version 5.3 with the 5300-08 Technology Level, or later
  • AIX Version 6.1 with the 6100-02 Technology Level and Service Pack 1, or later

Visit the IBM Prerequisite Web site for compatibility information for hardware features and the corresponding AIX Technology Levels

http://www-912.ibm.com/e_dir/eserverprereq.nsf

If installing Linux (one of these):

  • SUSE Linux Enterprise Server 10 Service Pack 2 for POWER, or later
  • Red Hat Enterprise Linux 4.6 for POWER, or later
  • Red Hat Enterprise Linux 5.2 for POWER, or later

Note: Not all system features available on the AIX operating system are available on the Linux operating systems.

Note: For systems ordered with the Linux operating system, IBM ships the most current version available from the distributor. If you require a different version than that shipped by IBM, you must obtain it via download from the Linux distributor's website. Information concerning access to a distributor's website is located on the product registration card delivered to you as part of your Linux operating system order.

Disclaimer: Some information in this announcement addresses anticipated future capabilitities and may be subject to change.
Back to topBack to top
 

Publications

The following information is shipped with the 575 (9125-F2A).

Standard printed deliverables that get shipped with the box are:

                Title                             Order number
-----------------------------------------         ------------
IBM Systems Safety Notices                        G229-9054
Statement of Limited Warranty                     SA76-0125
IBM License Agreement for Machine Code            Z125-5468
Verify FW Level Notification                      GI11-4284
Service Information DVD
SK5T-7090
 

Additional documentation is available through the IBM Systems Information Center, which provides you with a single information center where you can access product documentation for IBM systems hardware, operating systems, and server software. Through a consistent framework, you can efficiently find information and personalize your access. The IBM Systems Information Center is at:

www.ibm.com/systems/infocenter

Back to topBack to top
 
Features
TOC Link Features - No charge TOC Link Features - Chargeable TOC Link Feature descriptions
TOC Link Feature exchanges


Features - No charge

  • Languages
    • (#9300) -Language Group Specify - US English
    • (#9700) -Language Group Specify - Dutch
    • (#9703) -Language Group Specify - French
    • (#9704) -Language Group Specify - German
    • (#9705) -Language Group Specify - Polish
    • (#9706) -Language Group Specify - Norwegian
    • (#9707) -Language Group Specify - Portuguese
    • (#9708) -Language Group Specify - Spanish
    • (#9711) -Language Group Specify - Italian
    • (#9712) -Language Group Specify - Canadian French
    • (#9714) -Language Group Specify - Japanese
    • (#9715) -Language Group Specify - Traditional Chinese (Taiwan)
    • (#9716) -Language Group Specify - Korean
    • (#9718) -Language Group Specify - Turkish
    • (#9719) -Language Group Specify - Hungarian
    • (#9720) -Language Group Specify - Slovakian
    • (#9721) -Language Group Specify - Russian
    • (#9722) -Language Group Specify - Simplified Chinese (PRC)
    • (#9724) -Language Group Specify - Czech
    • (#9725) -Language Group Specify -- Romanian
    • (#9726) -Language Group Specify - Croatian
    • (#9727) -Language Group Specify -- Slovenian
    • (#9728) -Language Group Specify - Brazilian Portuguese
    • (#9729) -Language Group Specify - Thai

  • Miscellaneous
    • (#0983) -US TAA COMPLIANCE INDICATOR
    • (#1120) -Decline Electronic Service Agent Install Indicator
    • (#2146) -Primary OS - AIX
    • (#2147) -Primary OS - Linux

  • Specify Codes
    • (#0271) -Rack Content Specify: 9125-F2A
    • (#0318) -Rack Content Specify: I/O Drawer
    • (#4671) -First Shared I/O Drawer, Indicator
    • (#4672) -Second Shared I/O Drawer, Indicator
    • (#4673) -Third Shared I/O Drawer, Indicator
    • (#4674) -Fourth Shared I/O Drawer, Indicator
    • (#9440) - New AIX License Core Counter
    • (#9442) - New Red Hat License Core Counter
    • (#9443) - New SUSE License Core Counter
    • (#9444) - Other AIX License Core Counter
    • (#9445) - Other Linux License Core Counter
    • (#9446) - 3rd Party Linux Core Counter
    • (#9447) - VIOS Core Counter

Features - Chargeable

Special Features - Initial Orders

  • Administrative
    • (#0463) -SSD Placement Indicator (5802/5803)
    • (#0464) -SSD Placement Indicator - 5886

  • Miscellaneous
    • (#5005) -Software Preinstall

  • Processor
    • (#7298) -0/32 Core 4.7GHz POWER6 CPU

  • Specify Codes
    • (#8453) -Base Customer Spec Plcmnt

Special Features - Plant and/or Field Installable

  • Adapters
    • (#2728) -4 port USB PCIe Adapter
    • (#2738) -2-Port USB PCI Adapter
    • (#2849) -POWER GXT135P Graphics Accelerator with Digital Support
    • (#2943) -8-Port Asynchronous Adapter EIA-232/RS-422, PCI bus
    • (#2947) -IBM ARTIC960Hx 4-Port Multiprotocol PCI Adapter
    • (#2962) -2-Port Multiprotocol PCI Adapter
    • (#4599) -PCI Blind Swap Cassette Kit, Single Wide Adapters, Universal
    • (#4764) -PCI-X Cryptographic Coprocessor (FIPS 4)
    • (#5612) -Dual 2 Port 4x Host Channel Adapter
    • (#5700) -IBM Gigabit Ethernet-SX PCI-X Adapter
    • (#5701) -IBM 10/100/1000 Base-TX Ethernet PCI-X Adapter
    • (#5706) -IBM 2-Port 10/100/1000 Base-TX Ethernet PCI-X Adapter
    • (#5707) -IBM 2-Port Gigabit Ethernet-SX PCI-X Adapter
    • (#5708) -10Gb FCoE PCIe Dual Port Adapter
    • (#5710) -PCI-X Dual Channel Ultra320 SCSI Blind Swap Adapter
    • (#5713) -1 Gigabit iSCSI TOE PCI-X on Copper Media Adapter
    • (#5714) -1 Gigabit iSCSI TOE PCI-X on Optical Media Adapter
    • (#5716) -2 Gigabit Fibre Channel PCI-X Adapter
    • (#5717) -4-Port 10/100/1000 Base-TX PCI Express Adapter
    • (#5718) -10 Gigabit Ethernet -SR PCI-X Adapter
    • (#5719) -IBM 10 Gigabit Ethernet-LR PCI-X Adapter
    • (#5721) -10 Gb Ethernet-SR PCI-X 2.0 DDR Adapter
    • (#5722) -10 Gb Ethernet-LR PCI-X 2.0 DDR Adapter
    • (#5723) -2-Port Asynchronous EIA-232 PCI Adapter
    • (#5732) -10 Gigabit Ethernet-CX4 PCI Express Adapter
    • (#5735) -8 Gigabit PCI Express Dual Port Fibre Channel Adapter
    • (#5736) -PCI-X DDR Dual Channel Ultra320 SCSI Adapter
    • (#5740) -4-Port 10/100/1000 Base-TX PCI-X Adapter
    • (#5748) -POWER GXT145 PCI Express Graphics Accelerator
    • (#5758) -4 GB Single-Port Fibre Channel PCI-X 2.0 DDR Adapter
    • (#5759) -4 Gb Dual-Port Fibre Channel PCI-X 2.0 DDR Adapter
    • (#5767) -2-Port 10/100/1000 Base-TX Ethernet PCI Express Adapter
    • (#5768) -2-Port Gigabit Ethernet-SX PCI Express Adapter
    • (#5769) -10 Gigabit Ethernet-SR PCI Express Adapter
    • (#5772) -10 Gigabit Ethernet-LR PCI Express Adapter
    • (#5773) -4 Gigabit PCI Express Single Port Fibre Channel Adapter
    • (#5774) -4 Gigabit PCI Express Dual Port Fibre Channel Adapter
    • (#5785) -4 Port Async EIA-232 PCIe Adapter
    • (#5805) -PCIe 380MB Cache Dual - x4 3Gb SAS RAID Adapter
    • (#5900) -PCI-X DDR Dual -x4 SAS Adapter
    • (#5901) -PCIe Dual-x4 SAS Adapter
    • (#5902) -PCI-X DDR Dual - x4 3Gb SAS RAID Adapter
    • (#5903) -PCIe 380MB Cache Dual - x4 3Gb SAS RAID Adapter
    • (#5912) -PCI-X DDR Dual - x4 SAS Adapter
    • (#5922) Non-paired SAS RAID indicator
    • (#5923) -Non-paired PCIe SAS RAID Indicator

  • Cable
    • (#1829) -0.6 Meter 12X Cable
    • (#1830) -1.5 Meter 12X cable
    • (#1831) -2.5 Meter 12X Cable
    • (#1861) -0.6 Meter 12X DDR Cable
    • (#1862) -1.5 Meter 12X DDR Cable
    • (#1863) -2.5 Meter 12X DDR Cable
    • (#2118) -Converter Cable, VHDCI to P, Mini-68 pin to 68 pin, 0.3M
    • (#2425) -2.5M 16-bit SCSI-2 System-to-System Cable
    • (#2456) -2M LC-SC 50 Micron Fiber Converter Cable
    • (#2459) -2M LC-SC 62.5 Micron Fiber Converter Cable
    • (#2861) -ARTIC960Hx 4-Port EIA-232 Cable
    • (#2863) -ARTIC960Hx 4-Port X.21 Cable
    • (#2864) -ARTIC960Hx 4-Port V.35 (DTE) Cable
    • (#2934) -3M Asynchronous Terminal/Printer Cable EIA-232
    • (#2936) -Asynchronous Cable EIA-232/V.24 3M
    • (#2951) -Cable, V.24 / EIA-232
    • (#2952) -Cable, V.35
    • (#2953) -Cable, V.36 / EIA-499
    • (#2954) -Cable, X.21
    • (#3125) -Serial-to-Serial Port Cable for Rack/Rack
    • (#3291) -10 Meter QSFP-4x Optical Cable
    • (#3292) -20 meter QSFP-4x Optical Cable
    • (#3294) -40 meter QSFP-4x Optical Cable
    • (#3652) -SAS Cable (EE) Drawer to Drawer 1M
    • (#3653) -SAS Cable (EE) Drawer to Drawer 3M
    • (#3654) -SAS Cable (EE) Drawer to Drawer 6M
    • (#3661) -SAS Cable (X) Adapter to SAS Enclosure, Dual Controller/ Dual Path 3M
    • (#3662) -SAS Cable (X) Adapter to SAS Enclosure, Dual Controller/ Dual Path 6M
    • (#3663) -SAS Cable (X) Adapter to SAS Enclosure, Dual Controller/ Dual Path 15M
    • (#3684) -SAS Cable (AE) Adapter to Enclosure, single controller/ single path 3M
    • (#3685) -SAS Cable (AE) Adapter to Enclosure, single controller/ single path 6M
    • (#3688) -SAS Cable (AT) 0.6 Meter
    • (#3691) -SAS Cable (YO) Adapter to SAS Enclosure, Single Controller/Dual Path 1.5 M
    • (#3692) -SAS Cable (YO) Adapter to SAS Enclosure, Single Controller/Dual Path 3 M
    • (#3693) -SAS Cable (YO) Adapter to SAS Enclosure, Single Controller/Dual Path 6 M
    • (#3694) -SAS Cable (YO) Adapter to SAS Enclosure, Single Controller/Dual Path 15 M
    • (#3925) -0.3M Serial Port Converter Cable, 9-Pin to 25-Pin
    • (#3926) -Asynch Printer/Terminal Cable, 9-pin to 25-pin, 4M
    • (#3928) -Serial Port Null Modem Cable, 9-pin to 9-pin, 10M
    • (#6338) -Power and Ethernet cables EIA 05
    • (#6339) -Power and Ethernet cables EIA 07
    • (#6370) -Power and Ethernet cables EIA 09
    • (#6371) -Power and Ethernet cables EIA 11
    • (#6372) -Power and Ethernet cables EIA 13
    • (#6373) -Power and Ethernet cables EIA 15
    • (#6374) -Power and Ethernet cables EIA 17
    • (#6375) -Power and Ethernet cables EIA 19
    • (#6376) -Power and Ethernet cables EIA 21
    • (#6377) -Power and Ethernet cables EIA 23
    • (#6378) -Power and Ethernet cables EIA 25
    • (#6379) -Power and Ethernet cables EIA 27
    • (#6387) -Power and Ethernet cables EIA 29
    • (#6388) -Power and Ethernet cables EIA 31
    • (#6392) -Power cables EIA 05
    • (#6393) -Power cables EIA 09
    • (#6394) -Power cables EIA 13
    • (#6395) -Power cables EIA 17
    • (#6396) -Power cables EIA 21
    • (#6397) -Power cables EIA 25
    • (#6398) -Power cables EIA 29
    • (#7801) -Ethernet Cable, 6M, Hardware Management Console to System Unit
    • (#7802) -Ethernet Cable, 15M, Hardware Management Console to System Unit

  • Disk
    • (#1881) -73.4 GB 10K RPM SAS SFF Disk Drive
    • (#1882) -146.8 GB 10K RPM SAS SFF Disk Drive
    • (#1883) -73.4 GB 15K RPM SAS SFF Disk Drive
    • (#1885) -300GB 10K RPM SFF SAS Disk Drive
    • (#1886) -146GB 15K RPM SFF SAS Disk Drive
    • (#1890) -69GB SFF SAS Solid State Drive
    • (#3158) -36.4 GB 10,000 RPM Ultra3 SCSI Disk Drive Assembly
    • (#3159) -73.4 GB 10,000 RPM Ultra3 SCSI Disk Drive Assembly
    • (#3274) -73.4 GB 10,000 RPM Ultra320 SCSI Disk Drive Assembly
    • (#3275) -146.8 GB 10,000 RPM Ultra320 SCSI Disk Drive Assembly
    • (#3277) -36.4 GB 15,000 RPM Ultra320 SCSI Disk Drive Assembly
    • (#3278) -73.4 GB 15,000 RPM Ultra320 SCSI Disk Drive Assembly
    • (#3279) -146.8 GB 15,000 RPM Ultra320 SCSI Disk Drive Assembly
    • (#3578) -300 GB 10,000 RPM Ultra320 SCSI Disk Drive Assembly
    • (#3585) -300 GB 15K RPM SCSI Disk Drive
    • (#3586) -69GB 3.5" SAS Solid State Drive
    • (#3646) -73 GB 15K RPM SAS Disk Drive
    • (#3647) -146 GB 15K RPM SAS Disk Drive
    • (#3648) -300 GB 15K RPM SAS Disk Drive
    • (#3649) -450GB 15K RPM SAS Disk Drive

  • Linecords
    • (#6458) -Power Cable -- Drawer to IBM PDU, 14-foot, 250V/10A
    • (#6460) -Power Cord (14-foot), Drawer To OEM PDU (125V, 15A)
    • (#6469) -Power Cord (14-foot), Drawer to OEM PDU, (250V, 15A), U. S.
    • (#6470) -Power Cord (6-foot), To Wall (125V, 15A)
    • (#6471) -Power Cord (9-foot), To Wall/OEM PDU, (125V, 15A)
    • (#6472) -Power Cord (9-foot), To Wall/OEM PDU, (250V, 16A)
    • (#6473) -Power Cord (9-foot), To Wall/OEM PDU, (250V, 10A)
    • (#6474) -Power Cord (9-foot), To Wall/OEM PDU, (250V, 13A)
    • (#6475) -Power Cord (9-foot), To Wall/OEM PDU, (250V, 16A)
    • (#6476) -Power Cord (9-foot), To Wall/OEM PDU, (250V, 10A)
    • (#6477) -Power Cord (9-foot), To Wall/OEM PDU, (250V, 16A)
    • (#6478) -Power Cord (9-foot), To Wall/OEM PDU, (250V, 16A)
    • (#6487) -Power Cord (6-foot),To Wall, (250V, 15A), United States
    • (#6488) -Power Cord (9-foot), To Wall/OEM PDU, (125V, 15A or 250V, 10A )
    • (#6491) -14-Ft 1PH/48A Pwr Cord
    • (#6492) -14-Ft 1PH/48-60A Pwr Cord
    • (#6493) -Power Cord (9-foot), To Wall/OEM PDU, (250V, 10A)
    • (#6494) -Power Cord (9-foot), To Wall/OEM PDU, (250V, 10A)
    • (#6495) -Power Cord (9-foot), To Wall/OEM PDU, (250V, 10A)
    • (#6496) -Power Cord (9-foot), To Wall/OEM PDU, (250V, 10A)
    • (#6651) -Power Cord (9-foot), To Wall/OEM PDU, (125V, 15A)
    • (#6654) -14-Ft 1PH/24-30A Pwr Cord
    • (#6655) -14-Ft 1PH/24-30A WR Pwr Cord
    • (#6659) -Power Cord (9-foot), To Wall/OEM PDU, (250V, 15A)
    • (#6660) -Power Cord (14-foot), Drawer To OEM PDU (125V, 15A)
    • (#6669) -Power Cord (14-foot), Drawer to OEM PDU, (250V, 15A)
    • (#6670) -Power Cord (6-foot), To Wall (125V, 15A),
    • (#6671) -Power Cord (9-foot), Drawer to IBM PDU, 250V/10A
    • (#6672) -Power Cord (5-foot), Drawer to IBM PDU, 250V/10A
    • (#6680) -Power Cord (9-foot), To Wall/OEM PDU, (250V, 10A)
    • (#6687) -Power Cord (6-foot), To Wall, (250V, 15A)
    • (#8695) -Line Cord, 4AWG, 14ft, No Plug
    • (#8696) -Line Cord, 4AWG, 14ft, 100A Plug
    • (#8699) -Line Cord, 6AWG, 14ft, 60A Plug

  • Media Devices
    • (#2591) -External USB 1.44 MB Diskette Drive

  • Memory
    • (#5680) -Activation of 1GB DDR2 POWER6 Memory
    • (#5681) -Activation of 256 GB DDR2 POWER6 Memory
    • (#5684) -Activation of 100 GB DDR2 Memory
    • (#5687) -0/4GB (4X1GB) DIMMS, 533 MHz, DDR2, P6 CoD Memory
    • (#5688) -0/8GB (4X2GB) DIMMS, 533 MHz, DDR2, P6 CoD Memory
    • (#5698) -0/16GB (4X4GB) DIMMS, 533 MHz, DDR2, P6 CoD Memory

  • Miscellaneous
    • (#3759) -Universal Lift Tool and Service Ladder
    • (#3760) -Universal Lift Tool Adapters for Power 575
    • (#6319) -I/O Assembly without PCI capability
    • (#6345) -10 Gb Optical Transceivers (2x)
    • (#6389) -I/O Risers (4 PCI-E slots)
    • (#6399) -I/O Assembly with PCI and I/O Drawer Attachment Capability

  • Power
    • (#6328) -Bulk Power Distribution Assembly
    • (#6333) -Bulk Power Regulator
    • (#7109) -Intelligent PDU+, 1 EIA Unit, Universal UTG0247 Connector
    • (#7188) -Power Distribution Unit

  • Processor
    • (#7299) -One CPU activation for #7298

  • Rack Related
    • (#0553) -19 inch, 2.0 meter high rack
    • (#0599) -Rack Filler Panel Kit
    • (#5770) -System Rack with base power
    • (#5798) -12X I/O Drawer PCI-X, no repeater
    • (#5803) -12X I/O Drawer PCIe, SFF disk
    • (#5873) -12X I/O Drawer PCIe, no disk
    • (#5886) -EXP 12S Expansion Drawer
    • (#6069) -Opt Front Door for 2.0m Rack
    • (#6247) -2.0m Rack Trim Kit
    • (#6249) -2.0m Rack Acoustic Doors
    • (#6580) -Optional Rack Security Kit
    • (#6872) -Water cooling option
    • (#6873) -Coolant fill and purge tool
    • (#6874) -Slim doors with integrated rear heat exchanger
    • (#6875) -Acoustic doors with integrated rear heat exchanger
    • (#6876) -Coolant Supply/Return Hoses, 6'
    • (#6877) -Coolant Supply/Return Hoses, 14'
    • (#7937) -Bolt-Down Kit, Low-Raised Floor
    • (#7938) -Bolt-Down Kit, High-Raised Floor
    • (#7960) -Compact Handling Option

  • Specify Codes
    • (#0265) -AIX Partition Specify
    • (#0266) -Linux Partition Specify
    • (#4651) -Rack Indicator, Rack #1
    • (#4652) -Rack Indicator, Rack #2
    • (#4653) -Rack Indicator, Rack #3
    • (#4654) -Rack Indicator, Rack #4
    • (#4655) -Rack Indicator, Rack #5
    • (#4656) -Rack Indicator, Rack #6
    • (#4657) -Rack Indicator, Rack #7
    • (#4658) -Rack Indicator, Rack #8
    • (#4659) -Rack Indicator, Rack #9
    • (#4660) -Rack Indicator, Rack #10
    • (#4661) -Rack Indicator, Rack #11
    • (#4662) -Rack Indicator, Rack #12
    • (#4663) -Rack Indicator, Rack #13
    • (#4664) -Rack Indicator, Rack #14
    • (#4665) -Rack Indicator, Rack #15
    • (#4666) -Rack Indicator, Rack #16

  • Virtualization Engine
    • (#7949) -PowerVM - Standard
    • (#8024) -PowerVM - Enterprise

Feature Availability Matrix

The following feature availability matrix for MT 9125 uses the letter "A" to indicate features that are available and orderable on the specified models. "S" indicates a feature that is supported on the new model during a model conversion; these features will work on the new model, but additional quantities of these features cannot be ordered on the new model; they can only be removed. "N" indicates that the feature is not supported on the new model and must be removed during the model conversion. As additional features are announced, supported, or withdrawn, this list will be updated. Please check with your Marketing Representative for additional information.

        |F| A = AVAILABLE  S = SUPPORTED
        |2| N = NOT SUPPORTED, MUST BE REMOVED
        |A|
FEAT/PN | |        DESCRIPTION
--------|-|----------------------------------------------------------
0265    |A| AIX Partition Specify
0266    |A| Linux Partition Specify
0271    |A| Rack Content Specify: 9125-F2A
0318    |A| Rack Content Specify: I/O Drawer
0463    |S| SSD Placement Indicator (5802/5803)
0464    |S| SSD Placement Indicator - 5886
0553    |S| 19 inch, 2.0 meter high rack
0599    |S| Rack Filler Panel Kit
0983    |A| US TAA COMPLIANCE INDICATOR
1120    |S| Decline Electronic Service Agent Install Indicator
1829    |S| 0.6 Meter 12X Cable
1830    |S| 1.5 Meter 12X cable
1831    |S| 2.5 Meter 12X Cable
1861    |A| 0.6 Meter 12X DDR Cable
1862    |A| 1.5 Meter 12X DDR Cable
1863    |A| 2.5 Meter 12X DDR Cable
1881    |S| 73.4 GB 10K RPM SAS SFF Disk Drive
1882    |S| 146.8 GB 10K RPM SAS SFF Disk Drive
1883    |S| 73.4 GB 15K RPM SAS SFF Disk Drive
1885    |A| 300GB 10K RPM SFF SAS Disk Drive
1886    |A| 146GB 15K RPM SFF SAS Disk Drive
1890    |S| 69GB SFF SAS Solid State Drive
2118    |S| Converter Cable, VHDCI to P, Mini-68 pin to 68 pin, 0.3M
2146    |A| Primary OS - AIX
2147    |A| Primary OS - Linux
2425    |S| 2.5M 16-bit SCSI-2 System-to-System Cable
2456    |A| 2M LC-SC 50 Micron Fiber Converter Cable
2459    |A| 2M LC-SC 62.5 Micron Fiber Converter Cable
2591    |S| External USB 1.44 MB Diskette Drive
2728    |A| 4 port USB PCIe Adapter
2738    |S| 2-Port USB PCI Adapter
2849    |S| POWER GXT135P Graphics Accelerator with Digital Support
2861    |S| ARTIC960Hx 4-Port EIA-232 Cable
2863    |S| ARTIC960Hx 4-Port X.21 Cable
2864    |S| ARTIC960Hx 4-Port V.35 (DTE) Cable
2934    |A| 3M Asynchronous Terminal/Printer Cable EIA-232
2936    |A| Asynchronous Cable EIA-232/V.24 3M
2943    |S| 8-Port Asynchronous Adapter EIA-232/RS-422, PCI bus
2947    |S| IBM ARTIC960Hx 4-Port Multiprotocol PCI Adapter
2951    |S| Cable, V.24 / EIA-232
2952    |S| Cable, V.35
2953    |S| Cable, V.36 / EIA-499
2954    |S| Cable, X.21
2962    |S| 2-Port Multiprotocol PCI Adapter
3125    |A| Serial-to-Serial Port Cable for Rack/Rack
3158    |S| 36.4 GB 10,000 RPM Ultra3 SCSI Disk Drive Assembly
3159    |S| 73.4 GB 10,000 RPM Ultra3 SCSI Disk Drive Assembly
3274    |S| 73.4 GB 10,000 RPM Ultra320 SCSI Disk Drive Assembly
3275    |S| 146.8 GB 10,000 RPM Ultra320 SCSI Disk Drive Assembly
3277    |S| 36.4 GB 15,000 RPM Ultra320 SCSI Disk Drive Assembly
3278    |S| 73.4 GB 15,000 RPM Ultra320 SCSI Disk Drive Assembly
3279    |S| 146.8 GB 15,000 RPM Ultra320 SCSI Disk Drive Assembly
3291    |S| 10 Meter QSFP-4x Optical Cable
3292    |S| 20 meter QSFP-4x Optical Cable
3294    |S| 40 meter QSFP-4x Optical Cable
3578    |S| 300 GB 10,000 RPM Ultra320 SCSI Disk Drive Assembly
3585    |S| 300 GB 15K RPM SCSI Disk Drive
3586    |S| 69GB 3.5" SAS Solid State Drive
3646    |S| 73 GB 15K RPM SAS Disk Drive
3647    |S| 146 GB 15K RPM SAS Disk Drive
3648    |S| 300 GB 15K RPM SAS Disk Drive
3649    |S| 450 GB 15K RPM SAS Disk Drive
3652    |S| SAS Cable (EE) Drawer to Drawer 1M
3653    |S| SAS Cable (EE) Drawer to Drawer 3M
3654    |S| SAS Cable (EE) Drawer to Drawer 6M
3661    |S| SAS Cable (X) Adapter to SAS Enclosure, Dual
        | |Dual Path 3M
3662    |S| SAS Cable (X) Adapter to SAS Enclosure, Dual
        | |Dual Path 6M
3663    |S| SAS Cable (X) Adapter to SAS Enclosure, Dual
        | |Dual Path 15M
3684    |S| SAS Cable (AE) Adapter to Enclosure, Single
        | |single path 3M
3685    |S| SAS Cable (AE) Adapter to Enclosure, single controller
        | |single path 6M
3688    |A| SAS Cable (AT) 0.6 Meter
3691    |S| SAS Cable (YO) Adapter to SAS Enclosure,single Controller
        | |Dual Path 1.5 M
3692    |S| SAS Cable (YO) Adapter to SAS Enclosure,single Controller
        | |Dual Path 3 M
3693    |S| SAS Cable (YO) Adapter to SAS Enclosure,single Controller
        | |Dual Path 6 M
3694    |S| SAS Cable (YO) Adapter to SAS Enclosure,single Controller
        | |Dual Path 15 M
3759    |A| Universal Lift Tool and Service Ladder
3760    |A| Universal Lift Tool Adapters for Power 575
3925    |A| 0.3M Serial Port Converter Cable, 9-Pin to 25-Pin
3926    |S| Asynch Printer/Terminal Cable, 9-pin to 25-pin, 4M
3928    |A| Serial Port Null Modem Cable, 9-pin to 9-pin, 10M
4599    |A| PCI Blind Swap Cassette Kit, Single Wide Adapters,
        | |Universal
4651    |A| Rack Indicator, Rack #1
4652    |A| Rack Indicator, Rack #2
4653    |A| Rack Indicator, Rack #3
4654    |A| Rack Indicator, Rack #4
4655    |A| Rack Indicator, Rack #5
4656    |A| Rack Indicator, Rack #6
4657    |A| Rack Indicator, Rack #7
4658    |A| Rack Indicator, Rack #8
4659    |A| Rack Indicator, Rack #9
4660    |A| Rack Indicator, Rack #10
4661    |A| Rack Indicator, Rack #11
4662    |A| Rack Indicator, Rack #12
4663    |A| Rack Indicator, Rack #13
4664    |A| Rack Indicator, Rack #14
4665    |A| Rack Indicator, Rack #15
4666    |A| Rack Indicator, Rack #16
4671    |A| First Shared I/O Drawer, Indicator
4672    |A| Second Shared I/O Drawer, Indicator
4673    |A| Third Shared I/O Drawer, Indicator
4674    |A| Fourth Shared I/O Drawer, Indicator
4764    |S| PCI-X Cryptographic Coprocessor (FIPS 4)
5005    |S| Software Preinstall
5612    |S| Dual 2 Port 4x Host Channel Adapter
5680    |A| Activation of 1GB DDR2 POWER6 Memory
5681    |A| Activation of 256 GB DDR2 POWER6 Memory
5684    |A| Activation of 100 GB DDR2 Memory
5687    |S| 0/4GB (4X1GB) DIMMS, 533 MHz, DDR2, P6 CoD Memory
5688    |S| 0/8GB (4X2GB) DIMMS, 533 MHz, DDR2, P6 CoD Memory
5698    |S| 0/16GB (4X4GB) DIMMS, 533 MHz, DDR2, P6 CoD Memory
5700    |S| IBM Gigabit Ethernet-SX PCI-X Adapter
5701    |S| IBM 10/100/1000 Base-TX Ethernet PCI-X Adapter
5706    |A| IBM 2-Port 10/100/1000 Base-TX Ethernet PCI-X Adapter
5707    |S| IBM 2-Port Gigabit Ethernet-SX PCI-X Adapter
5708    |A| 10Gb FCoE PCIe Dual Port Adapter
5710    |S| PCI-X Dual Channel Ultra320 SCSI Blind Swap Adapter
5713    |A| 1 Gigabit iSCSI TOE PCI-X on Copper Media Adapter
5714    |A| 1 Gigabit iSCSI TOE PCI-X on Optical Media Adapter
5716    |S| 2 Gigabit Fibre Channel PCI-X Adapter
5717    |S| 4-Port 10/100/1000 Base-TX PCI Express Adapter
5718    |S| 10 Gigabit Ethernet -SR PCI-X Adapter
5719    |S| IBM 10 Gigabit Ethernet-LR PCI-X Adapter
5721    |S| 10 Gb Ethernet-SR PCI-X 2.0 DDR Adapter
5722    |S| 10 Gb Ethernet-LR PCI-X 2.0 DDR Adapter
5723    |S| 2-Port Asynchronous EIA-232 PCI Adapter
5732    |S| 10 Gigabit Ethernet-CX4 PCI Express Adapter
5735    |A| 8 Gigabit PCI Express Dual Port Fibre Channel Adapter
5736    |S| PCI-X DDR Dual Channel Ultra320 SCSI Adapter
5740    |S| 4-Port 10/100/1000 Base-TX PCI-X Adapter
5748    |A| POWER GXT145 PCI Express Graphics Accelerator
5758    |S| 4 GB Single-Port Fibre Channel PCI-X 2.0 DDR Adapter
5759    |S| 4 Gb Dual-Port Fibre Channel PCI-X 2.0 DDR Adapter
5767    |A| 2-Port 10/100/1000 Base-TX Ethernet PCI Express Adapter
5768    |A| 2-Port Gigabit Ethernet-SX PCI Express Adapter
5770    |S| System Rack with base power
5772    |A| 10 Gigabit Ethernet-LR PCI Express Adapter
5773    |A| 4 Gigabit PCI Express Single Port Fibre Channel Adapter
5774    |A| 4 Gigabit PCI Express Dual Port Fibre Channel Adapter
5769    |A| 10 Gigabit Ethernet-SR PCI Express Adapter
5785    |A| 4 Port Async EIA-232 PCIe Adapter
5798    |S| 12X I/O Drawer PCI-X, no repeater
5803    |A| 12X I/O Drawer PCIe, SFF disk
5805    |A| PCIe 380MB Cache Dual - x4 3Gb SAS RAID Adapter
5873    |A| 12X I/O Drawer PCIe, no disk
5886    |S| EXP 12S Expansion Drawer
5900    |S| PCI-X DDR Dual -x4 SAS Adapter
5901    |A| PCIe Dual-x4 SAS Adapter
5902    |S| PCI-X DDR Dual - x4 3Gb SAS RAID Adapter
5903    |S| PCIe 380MB Cache Dual - x4 3Gb SAS RAID Adapter
5912    |S| PCI-X DDR Dual - x4 SAS Adapter
5922    |A| Non-paired SAS RAID indicator
5923    |A| Non-paired PCIe SAS RAID Indicator
6069    |S| Opt Front Door for 2.0m Rack
6239    |N| 2 Gigabit Fibre Channel PCI-X Adapter
6247    |S| 2.0m Rack Trim Kit
6249    |S| 2.0m Rack Acoustic Doors
6319    |S| I/O Assembly without PCI capability
6328    |S| Bulk Power Distribution Assembly
6333    |A| Bulk Power Regulator
6338    |A| Power and Ethernet cables EIA 05
6339    |A| Power and Ethernet cables EIA 07
6345    |S| 10 Gb Optical Transceivers (2x)
6370    |A| Power and Ethernet cables EIA 09
6371    |A| Power and Ethernet cables EIA 11
6372    |A| Power and Ethernet cables EIA 13
6373    |A| Power and Ethernet cables EIA 15
6374    |A| Power and Ethernet cables EIA 17
6375    |A| Power and Ethernet cables EIA 19
6376    |A| Power and Ethernet cables EIA 21
6377    |A| Power and Ethernet cables EIA 23
6378    |A| Power and Ethernet cables EIA 25
6379    |A| Power and Ethernet cables EIA 27
6387    |A| Power and Ethernet cables EIA 29
6388    |A| Power and Ethernet cables EIA 31
6389    |S| I/O Risers (4 PCI-E slots)
6392    |A| Power cables EIA 05
6393    |A| Power cables EIA 09
6394    |A| Power cables EIA 13
6395    |A| Power cables EIA 17
6396    |A| Power cables EIA 21
6397    |A| Power cables EIA 25
6398    |A| Power cables EIA 29
6399    |S| I/O Assembly with PCI &I/O Drawer Attachment Capability
6458    |S| Power Cable -- Drawer to IBM PDU, 14-foot, 250V/10A
6460    |S| Power Cord (14-foot), Drawer To OEM PDU (125V, 15A)
6469    |S| Power Cord (14-foot), Drawer to OEM PDU (250V, 15A) U.S.
6470    |S| Power Cord (6-foot), To Wall (125V, 15A)
6471    |S| Power Cord (9-foot), To Wall/OEM PDU, (125V, 15A)
6472    |S| Power Cord (9-foot), To Wall/OEM PDU, (250V, 16A)
6473    |S| Power Cord (9-foot), To Wall/OEM PDU, (250V, 10A)
6474    |S| Power Cord (9-foot), To Wall/OEM PDU, (250V, 13A)
6475    |S| Power Cord (9-foot), To Wall/OEM PDU, (250V, 16A)
6476    |S| Power Cord (9-foot), To Wall/OEM PDU, (250V, 10A)
6477    |S| Power Cord (9-foot), To Wall/OEM PDU, (250V, 16A)
6478    |S| Power Cord (9-foot), To Wall/OEM PDU, (250V, 16A)
6487    |S| Power Cord (6-foot),To Wall, (250V, 15A), United States
6488    |S| Power Cord (9-foot), To Wall/OEM PDU, (125V, 15A or 250V,
        | |10A )
6492    |S| 14-Ft 1PH/48-60A Pwr Cord
6493    |S| Power Cord (9-foot), To Wall/OEM PDU, (250V, 10A)
6494    |S| Power Cord (9-foot), To Wall/OEM PDU, (250V, 10A)
6495    |S| Power Cord (9-foot), To Wall/OEM PDU, (250V, 10A)
6496    |S| Power Cord (9-foot), To Wall/OEM PDU, (250V, 10A)
6580    |S| Optional Rack Security Kit
6651    |S| Power Cord (9-foot), To Wall/OEM PDU, (125V, 15A)
6654    |S| 14-Ft 1PH/24-30A Pwr Cord
6655    |S| 14-Ft 1PH/24-30A WR Pwr Cord
6659    |S| Power Cord (9-foot), To Wall/OEM PDU, (250V, 15A)
6660    |S| Power Cord (14-foot), Drawer To OEM PDU (125V, 15A)
6669    |S| Power Cord (14-foot), Drawer to OEM PDU, (250V, 15A)
6670    |S| Power Cord (6-foot), To Wall (125V, 15A),
6671    |S| Power Cord (9-foot), Drawer to IBM PDU, 250V/10A
6672    |S| Power Cord (5-foot), Drawer to IBM PDU, 250V/10A
6680    |S| Power Cord (9-foot), To Wall/OEM PDU, (250V, 10A)
6687    |S| Power Cord (6-foot), To Wall, (250V, 15A)
6872    |S| Water cooling option
6873    |S| Coolant fill and purge tool
6874    |S| Slim doors with integrated rear heat exchanger
6875    |S| Acoustic doors with integrated rear heat exchanger
6876    |A| Coolant Supply/Return Hoses, 6'
6877    |A| Coolant Supply/Return Hoses, 14'
7109    |S| Intelligent PDU+, 1 EIA Unit, Universal UTG0247 Connector
7188    |S| Power Distribution Unit
7298    |S| 0/32 Core 4.7GHz POWER6 CPU
7299    |A| One CPU activation for #7298
7801    |A| Ethernet Cable, 6M, Hardware Management Console to
        | | System Unit
7802    |A| Ethernet Cable, 15M, Hardware Management Console to
        | | System Unit
7937    |A| Bolt-Down Kit, Low-Raised Floor
7938    |A| Bolt-Down Kit, High-Raised Floor
7949    |A| PowerVM - Standard
7960    |A| Compact Handling Option
8024    |A| PowerVM - Enterprise
8453    |A| Base Customer Spec Plcmnt
8695    |A| Line Cord, 4AWG, 14ft, No Plug
8696    |A| Line Cord, 4AWG, 14ft, 100A Plug
8699    |A| Line Cord, 6AWG, 14ft, 60A Plug
9300    |A| Language Group Specify - US English
9440    |S| New AIX License Core Counter
9442    |S| New Red Hat License Core Counter
9443    |S| New SUSE License Core Counter
9444    |S| Other AIX License Core Counter
9445    |S| Other Linux License Core Counter
9446    |S| 3rd Party Linux License Core Counter
9447    |S| VIOS Core Counter
9700    |S| Language Group Specify - Dutch
9703    |S| Language Group Specify - French
9704    |S| Language Group Specify - German
9705    |S| Language Group Specify - Polish
9706    |S| Language Group Specify - Norwegian
9707    |S| Language Group Specify - Portuguese
9708    |S| Language Group Specify - Spanish
9711    |S| Language Group Specify - Italian
9712    |S| Language Group Specify - Canadian French
9714    |S| Language Group Specify - Japanese
9715    |S| Language Group Specify - Traditional Chinese (Taiwan)
9716    |S| Language Group Specify - Korean
9718    |S| Language Group Specify - Turkish
9719    |S| Language Group Specify - Hungarian
9720    |S| Language Group Specify - Slovakian
9721    |S| Language Group Specify - Russian
9722    |S| Language Group Specify - Simplified Chinese (PRC)
9724    |S| Language Group Specify - Czech
9725    |S| Language Group Specify -- Romanian
9726    |S| Language Group Specify - Croatian
9727    |S| Language Group Specify -- Slovenian
9728    |S| Language Group Specify - Brazilian Portuguese
9729    |S| Language Group Specify - Thai
 

Feature descriptions

The following is a list of all feature codes in numeric order for the IBM System p 9125 machine type.

Attributes, as defined in the following feature descriptions, state the interaction of requirements among features.

Minimums and maximums are the absolute limits for a single feature without regard to interaction with other features. The maximum valid quantity for MES orders may be different than for initial orders. The maximums listed below refer to the largest quantity of these two possibilities.

The order type defines if a feature is orderable only on initial orders, only on MES orders, on both initial and MES orders, or if a feature is supported on a model due to a model conversion. Supported features cannot be ordered on the converted model, only left on or removed from the converted model.

(#0265) AIX Partition Specify

This feature indicates customers intend to create a partition on the system that will use the AIX operating system. This feature should be included once for each intended AIX partition. This feature is an indicator and does not deliver parts, software, or services.

  • Attributes provided: None
  • Attributes required: Customers intend to create a partition on the system that will run the AIX operating system.
  • For 9125-F2A: (#0265)
    • Minimum required: 0
    • Maximum allowed: 254 (Initial order maximum: 254)
    • OS level required:
      • AIX 5L for POWER V5.3 with the 5300-08 Technology Level
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: Does not apply

(#0266) Linux Partition Specify

This feature indicates customers intend to create a partition on the system that will use the Linux operating system. This feature should be included once for each intended Linux partition. This feature is an indicator and does not deliver parts, software, or services.

  • Attributes provided: None
  • Attributes required: Customers intend to create a partition on the system that will run the Linux operating system.
  • For 9125-F2A: (#0266)
    • Minimum required: 0
    • Maximum allowed: 254 (Initial order maximum: 254)
    • OS level required: Linux - Refer to the following URL for systems and features that operate with Linux:

      http://www.ibm.com/servers/eserver/pseries/ hardware/factsfeatures.html  

    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: Does not apply

(#0271) Rack Content Specify: 9125-F2A

Indicator of rack space utilization for a 9125-F2A node.

  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 2U of rack space
  • For 9125-F2A: (#0271)
    • Minimum required: 0
    • Maximum allowed: 16 (Initial order maximum: 16)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: Does not apply

(#0318) Rack Content Specify: I/O Drawer

Indicator of rack space utilization for 12X attached PCI-X or PCIe I/O Drawer.

  • Attributes provided: Indicator of rack space utilization
  • Attributes required: 4U of rack space
  • For 9125-F2A: (#0318)
    • Minimum required: 0
    • Maximum allowed: 5 (Initial order maximum: 5)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: Does not apply

(#0463) - SSD Placement Indicator (5802/5803)

(No Longer Available as of July 30, 2010)

This is an IBM internal automatic generated SSD specify indicator for placement and it is not selectable.

  • Attributes provided: None
  • Attributes required: None
  • For 9125-F2A: (#0463)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply

    Note: #0464 is used with #5886

(#0464) - SSD Placement Indicator - 5886

(No Longer Available as of July 14, 2009)

This is an IBM internal automatic generated SSD specify indicator for placement and it is not selectable.

  • Attributes provided: None
  • Attributes required: None
  • For 9125-F2A: (#0464)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 0)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply

(#0553) 19 inch, 2.0 meter high rack

(No Longer Available as of July 14, 2009)

Provides a 19-inch, 2.0 meter high rack with 42 EIA units of total space for installing rack mounted CECs and/or expansion units. One of the following features are required on the #0553:

  • #6069 - Optional Front Door for 2.0m Rack
  • #6247 - 2.0m Rack Trim Kit
  • #6249 - 2.0m Rack Acoustic Doors

The #0553 can support up to nine power distribution units (PDU), four mounted vertically and five mounted horizontally. Each PDU mounted horizontally takes up 1 EIA of rack space. The following PDUs are supported:

  • #7188 - Power Distribution Unit (12, C13 sockets)
  • #7109 - Power Distribution Unit (12, C13 sockets)
  • Attributes provided: 19 inch, 2.0M, 42 EIA Rack
  • Attributes required: #6069 or #6247 or #6249
  • For 9125-F2A: (#0553)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#0599) Rack Filler Panel Kit

(No Longer Available as of July 14, 2009)

Provides rack filler panels for IBM 19-inch racks. The #0599 provides three 1-EIA -unit filler panels and one 3-EIA-unit filler panel. These are snap-on panels.

  • Attributes provided: Snap on rack filler panels
  • Attributes required: 19-inch rack
  • For 9125-F2A: (#0599)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#0983) US TAA COMPLIANCE INDICATOR

This feature indicates that the product was assembled in a manufacturing plant in the USA or in a country approved under the US Trade Agreement Act.

  • Attributes provided: None
  • Attributes required: None
  • For 9125-F2A: (#0983)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: Does not apply

(#1120) Decline Electronic Service Agent Install Indicator

(No Longer Available as of July 30, 2010)

Electronic Service Agent is a basic component of the Power Systems server and is an important tool in maintaining the high availability expected from your IBM system and the service response time you expect from your IBM service team. You should select this feature only if you do not intend to have the IBM SSR install ESA at the time your system is being installed. Before selecting this feature please discuss this decision with your IBM Account Team or IBM Business Partner.

Electronic Service Agent installation by an IBM SSR is available to you for no additional charge during initial server installation only.

  • Attributes provided: Documents Customers intention to not allow the IBM SSR to install Electronic Service Agent during system installation
  • Attributes required: none
  • For 9125-F2A: (#1120)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES:

(#1829) 0.6 Meter 12X Cable

(No Longer Available as of October 30, 2009)

When used with a 19-inch rack mount I/O drawer, this 0.6 Meter cable is used in a 12X channel external I/O Drawer attachment loop between two 12X channel I/O drawers in the same loop.

When used with a 24-inch rack mount I/O drawer, this 0.6 Meter cable is used as a jumper between the two halves of the I/O Drawer when both halves are included in the same 12X loop.

Note: Substitute appropriate cable length SDR/DDR feature 1861, 1862, 1864, or 1865 after October 30, 2009)

  • Attributes provided: 0.6 Meter 12X cable
  • Attributes required: 12X Channel remote I/O drawer loop
  • For 9125-F2A: (#1829)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#1830) 1.5 Meter 12X cable

(No Longer Available as of October 30, 2009)

This 1.5 Meter cable is used to attach a 12X channel I/O Drawer to a 12X channel adapter in the Host system or can be used between two I/O drawers in a 12X channel loop.

Select the 12X cable length, from those offered that best meets your cabling needs.

Note: Substitute appropriate cable length SDR/DDR feature 1861, 1862, 1864, or 1865 after October 30, 2009)

  • Attributes provided: 1.5 Meter 12X cable
  • Attributes required: 12X Channel remote I/O drawer loop
  • For 9125-F2A: (#1830)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#1831) 2.5 Meter 12X Cable

(No Longer Available as of October 30, 2009)

This 2.5 Meter cable is used to attach a 12X channel I/O Drawer to a 12X channel adapter in the Host system or can be used between two I/O drawers in a 12X channel loop.

Select the 12X cable length, from those offered that best meets your cabling needs.

  • Attributes provided: 2.5 Meter 12X Cable
  • Attributes required: 12X Channel remote I/O drawer loop
  • For 9125-F2A: (#1831)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#1861) - 0.6 Meter 12X DDR Cable

When used with a 24-inch rack mount I/O drawer, this 0.6 Meter DDR cable is used as a jumper between the two halves of the I/O Drawer when both halves are included in the same 12X loop.

  • Attributes provided: 0.6 Meter 12X DDR cable
  • Attributes required: none
  • For 9125-F2A: (#1861)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#1862) - 1.5 Meter 12X DDR Cable

This 1.5 Meter DDR cable is used to attach a 12X channel I/O Drawer to a 12X channel adapter in the Host system or can be used between two I/O drawers in a 12X channel loop.

  • Attributes provided: 1.5 Meter 12X DDR cable
  • Attributes required: none
  • For 9125-F2A: (#1862)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#1863) - 2.5 Meter 12X DDR Cable

This 2.5 Meter DDR cable is used to attach a 12X channel I/O Drawer to a 12X channel adapter in the Host system or can be used between two I/O drawers in a 12X channel loop.

Select the 12X DDR cable length, from those offered that best meets your cabling needs.

  • Attributes provided: 2.5 Meter 12X DDR Cable
  • Attributes required: None
  • For 9125-F2A: (#1863)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#1881) 73.4 GB 10K RPM SAS SFF Disk Drive

(No Longer Available as of June 26, 2009)

73.4 GB SFF SAS disk, in a carrier capable of providing Hot Swap support. Provides 73.4 GB of storage capacity. Supports the industry standard SAS interface. Can be used only in a system designed to support the SAS SFF disk drive in a carrier.

Characteristics:

  • Form Factor: SSF SAS compliant (2.5" x 15mm form factor)
  • Cable included: None
  • External Interface: standard SAS Dual Port
  • Rotational Speed: 10,000 RPM
  • Interface Speed: 3Gbs (300 MBs)
  • Format: 512 Bytes/sector default, 528 Bytes/sector possible with reformat.
  • Attributes provided: 73.4 GB of disk storage mounted in a carrier.
  • Attributes required: one SFF SAS disk drive bay slot
  • For 9125-F2A: (#1881)
    • Minimum required: 0
    • Maximum allowed: 28 (Initial order maximum: 28)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#1882) 146.8 GB 10K RPM SAS SFF Disk Drive

(No Longer Available as of November 26, 2010)

146.8 GB SFF SAS disk, in a carrier capable of providing Hot Swap support. Provides 146.8 GB of storage capacity. Supports the industry standard SAS interface. Can be used only in a system designed to support the SAS SFF disk drive in a carrier.

Characteristics:

  • Form Factor: SSF SAS compliant (2.5" x 15mm form factor)
  • Cable included: None
  • External Interface: standard SAS Dual Port
  • Rotational Speed: 10,000 RPM
  • Interface Speed: 3Gbs (300 MBs)
  • Format: 512 Bytes/sector default, 528 Bytes/sector possible with reformat.
  • Attributes provided: 146.8 GB of Disk Storage mounted in a carrier
  • Attributes required: one SFF SAS disk drive bay slot
  • For 9125-F2A: (#1882)
    • Minimum required: 0
    • Maximum allowed: 28 (Initial order maximum: 28)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#1883) - 73.4 GB 15K RPM SAS SFF Disk Drive

(No Longer Available as of April 29, 2011)

73.4 GB SFF SAS disk, in a carrier capable of providing Hot Swap support. Provides 73.4 GB of storage capacity. Supports the industry standard SAS interface. Can be used only in a system designed to support the SAS SFF disk drive in a carrier.

Characteristics:

  • Form Factor: SFF SAS compliant (2.5" x 15mm form factor)
  • Cable included: None
  • External Interface: standard SAS Dual Port
  • Rotational Speed: 15,000 RPM
  • Interface Speed: 3Gbs (300 MBs)
  • Format: 512 Bytes/sector
  • Attributes provided: 73.4 GB of disk storage mounted in a carrier.
  • Attributes required: One SFF SAS disk drive bay slot
  • For 9125-F2A: (#1883)
    • Minimum required: 0
    • Maximum allowed: 28 (Initial order maximum: 28)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

    Note: Max of two in the CEC and up to 26 in #5803.

(#1885) - 300GB 10K RPM SFF SAS Disk Drive

300GB SFF SAS disk, in a carrier capable of providing Hot Swap support. The disk supports the industry standard SAS interface. Systems that accept SAS SFF disk drive in a carrier accommodate this SAS disk.

Characteristics:

  • Form Factor: SSF SAS compliant (2.5" x 15mm form factor)
  • Cable included: None
  • External Interface: standard SAS Dual Port
  • Rotational Speed: 10,000 RPM
  • Interface Speed: 3Gbs (300 MBs)
  • Format: 512 Bytes/sector default, 528 Bytes/sector possible with reformat.
  • Attributes provided: 300GB of Disk Storage mounted in a carrier
  • Attributes required: one SFF SAS disk drive bay slot
  • For 9125-F2A: (#1885)
    • Minimum required: 0
    • Maximum allowed: 28 (Initial order maximum: 28)
    • OS level required:
      • AIX 5.3 with the 5300-11 Technology Level, or later
      • AIX 5.3 with the 5300-10 Technology Level and Service Pack 2, or later
      • AIX 5.3 with the 5300-09 Technology Level and Service Pack 5, or later
      • AIX 5.3 with the 5300-08 Technology Level and Service Pack 8, or later
      • AIX 6.1 with the 6100-04 Technology Level, or later
      • AIX 6.1 with the 6100-03 Technology Level and Service Pack 3, or later
      • AIX 6.1 with the 6100-02 Technology Level and Service Pack 6, or later
      • AIX 6.1 with the 6100-01 Technology Level and Service Pack 7, or later
      • AIX levels requiring service packs will be available on or before January 31, 2010.
      • SUSE Linux Enterprise Server 10 Service Pack 1 or later
      • SUSE Linux Enterprise Server 11 or later
      • Red Hat Enterprise Linux 4.6 or later
      • Red Hat Enterprise Linux 5.1 or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

    Note: #5803 accommodates up to 26 SFF SAS drives; VIOS attachment requires VIOS 2.1.2.0 or later.

(#1886) - 146GB 15K RPM SFF SAS Disk Drive

146.8 GB SFF SAS disk, in a carrier capable of providing Hot Swap support. Provides 146.8 GB of storage capacity. Supports the industry standard SAS interface. Can be used only in a system designed to support the SAS SFF disk drive in a carrier.

Characteristics:

  • Form Factor: SFF SAS compliant (2.5" x 15mm form factor)
  • Cable included: None
  • External Interface: standard SAS Dual Port
  • Rotational Speed: 15,000 RPM
  • Interface Speed: 3Gbs (300 MBs)
  • Format: 512 Bytes/sector
  • Attributes provided: 146.8 GB of disk storage mounted in a carrier.
  • Attributes required: One SFF SAS disk drive bay slot
  • For 9125-F2A: (#1886)
    • Minimum required: 0
    • Maximum allowed: 28 (Initial order maximum: 28)
    • OS level required:
      • AIX 5.3 with the 5300-11 Technology Level, or later
      • AIX 5.3 with the 5300-10 Technology Level and Service Pack 2, or later
      • AIX 5.3 with the 5300-09 Technology Level and Service Pack 5, or later
      • AIX 5.3 with the 5300-08 Technology Level and Service Pack 8, or later
      • AIX 6.1 with the 6100-04 Technology Level, or later
      • AIX 6.1 with the 6100-03 Technology Level and Service Pack 3, or later
      • AIX 6.1 with the 6100-02 Technology Level and Service Pack 6, or later
      • AIX 6.1 with the 6100-01 Technology Level and Service Pack 7, or later
      • AIX levels requiring service packs will be available on or before January 31, 2010.
      • SUSE Linux Enterprise Server 10 Service Pack 1 or later
      • SUSE Linux Enterprise Server 11 or later
      • Red Hat Enterprise Linux 4.6 or later
      • Red Hat Enterprise Linux 5.1 or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

    Note:

    • Max of two in the CEC and up to 26 in #5803
    • VIOS attachment requires VIOS 2.1.2.0 or later

(#1890) - 69GB SFF SAS Solid State Drive

(No Longer Available as of July 29, 2011)

The 69GB SFF SAS Solid State Drive (SSD) provides 69.7 GB of very high performance storage, much faster than spinning disk drives with their delays due to positioning the disk arm and waiting for the spinning disk to rotate under the arm. SSD also provide lower power utilization than spinning or hard disk drives (HDD). The drive is formatted to 69.7 GB and can be used by AIX, Linux (#1890) and IBM i (#1909). Both are identical drives, but have different feature codes to help the IBM configuration tools understand how the SSD is used.

  • Connector - standard SAS dual port
  • 3Gb/sec SAS device (300 MB/sec)
  • 528 bytes sectors Power System
  • Attributes provided: 69.7 GB of formatted drive storage mounted in a SFF carrier
  • Attributes required: One SFF SAS drive bay in the 8203-E4A or 8204-E8A CEC or available SFF SAS bay in 12X I/O Drawer PCIe, SFF disk. SAS Disk and SSD on same backplane is not supported.
  • For 9125-F2A: (#1890)
    • Minimum required: 0
    • Maximum allowed: 18 (Initial order maximum: 18)
    • OS level required:
      • AIX 5.3 with the 5300-11 Technology Level, or later
      • AIX 5.3 with the 5300-10 Technology Level and Service Pack 2, or later
      • AIX 5.3 with the 5300-09 Technology Level and Service Pack 5, or later
      • AIX 5.3 with the 5300-08 Technology Level and Service Pack 8, or later
      • AIX 6.1 with the 6100-04 Technology Level, or later
      • AIX 6.1 with the 6100-03 Technology Level and Service Pack 3, or later
      • AIX 6.1 with the 6100-02 Technology Level and Service Pack 6, or later
      • AIX 6.1 with the 6100-01 Technology Level and Service Pack 7, or later
      • AIX requiring service packs will be available on or before January 31, 2010.
      • SUSE Linux Enterprise Server 10 Service Pack 1 or later
      • SUSE Linux Enterprise Server 11 or later
      • Red Hat Enterprise Linux 4.6 or later
      • Red Hat Enterprise Linux 5.1 or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

    Note: VIOS attachment requires VIOS 2.1.2.0 or later

(#2118) Converter Cable, VHDCI to P, Mini-68 pin to 68 pin, 0.3M

0.3M 16-bit SCSI cable used to convert from a Mini-68 pin VHDCI connector to a 68-pin P style connector. Cable has male Mini-68 pin VHDCI connector on one end and a female 68 pin P style connector on the other. Length = 0.3 meters.

  • Attributes provided: Attachment of supported external sub-system to integrated SCSI port or SCSI adapter with VHDCI Mini-68 pin connector.
  • Attributes required: None
  • For 9125-F2A: (#2118)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 0)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Supported
    • CSU: No
    • Return parts MES: No

(#2146) Primary OS - AIX

Indicates clients intend to use the AIX operating system on the primary system partition. This feature is used as a Manufacturing Routing indicator and does not deliver parts, software or services.

  • Attributes provided: None
  • Attributes required: Indicates clients intend to use the AIX operating system on the primary system partition.
  • For 9125-F2A: (#2146)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required:
      • AIX 5L for POWER version 5.3 with the 5300-08 Technology Level, or later
      • AIX Version 6.1 with the 6100-02 Technology Level and Service Pack 1, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: Does not apply

(#2147) Primary OS - Linux

Indicates clients intend to use the Linux operating system on the primary system partition. This feature is used as a Manufacturing Routing indicator and does not deliver parts, software or services.

  • Attributes provided: None
  • Attributes required: Indicates clients intend to use the Linux operating system on the primary system partition.
  • For 9125-F2A: (#2147)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required:
      • SUSE Linux Enterprise Server 10 Service Pack 2 for POWER, or later
      • Red Hat Enterprise Linux 4.6 for POWER, or later
      • Red Hat Enterprise Linux 5.2 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: Does not apply

(#2425) 2.5M 16-bit SCSI-2 System-to-System Cable

This cable provides a 16-bit connection between any two differential or single ended SCSI devices having 68-pin connectors. It can be used to attach an external SCSI device to a SCSI adapter card in an RS/6000 system.

  • Attributes provided: 2.5 meter SCSI cable with 68-pin connectors at each end
  • Attributes required: 68-pin SCSI Interface
  • For 9125-F2A: (#2425)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 0)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Supported
    • CSU: No
    • Return parts MES: No

(#2456) 2M LC-SC 50 Micron Fiber Converter Cable

The 50 micron fiber cable is used to convert from LC type to SC type connectors. The 2 meter cable has a male LC type connector on one end and a female SC type connector on the other.

  • Attributes provided: Cable with (1X) LC type plug and (1X) SC type receptacle
  • Attributes required: None
  • For 9125-F2A: (#2456)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#2459) 2M LC-SC 62.5 Micron Fiber Converter Cable

The 62.5 micron fiber cable is used to convert from LC type to SC type connectors. The 2 meter cable has a male LC type connector on one end and a female SC type connector on the other.

  • Attributes provided: Cable with (1X) LC type plug and (1X) SC type receptacle
  • Attributes required: None
  • For 9125-F2A: (#2459)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#2591) External USB 1.44 MB Diskette Drive

The externally attached USB diskette drive provides storage capacity up to 1.44 MB on a high density (2HD) floppy disk and 720 KB on a double density floppy disk. Includes 350mm (13.7 in) captured cable with standard USB connector.

Limitation:

  • Maximum 1 USB diskette per adapter,
  • Up to 1 Keyboard and Mouse also supported on the adapter with the diskette drive at the same time
  • No system boot capability
  • Not to be operated upside down or with eject button down

Characteristics:

  • Capacity - 1.44 MB (2HD disk) or 720 KB (double density disk)
  • Physical Dimensions: Width=103mm (4.05 in), Height=17.6mm (.69 in), Depth=141.8mm (5.58 in)
  • Color: Black
  • Data Rate: 12 Mbits/sec
  • Max Power Consumption: 2.36 Watt (seek)
  • Operates in all positions except those noted in the limitations above
  • Attributes provided: External diskette drive
  • Attributes required: 1 available USB port
  • For 9125-F2A: (#2591)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 0)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Supported
    • CSU: No
    • Return parts MES: No

(#2728) 4 port USB PCIe Adapter

The PCI-Express 4 port USB adapter provides support for USB devices. In applications that require the use of an USB extension cable, use one FC 4256 per port.

  • Attributes provided: Connectivity with USB 1.0 - 2.0 capable devices
  • Attributes required: One available PCI-Express slot
  • For 9125-F2A: (#2728)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 8)
    • OS level required: Refer to "Software Requirements" in Sales Manual.
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

    Note: AIX only supports USB 1.1.

(#2738) 2-Port USB PCI Adapter

(No Longer Available as of November 27, 2009)

The 2 Port USB PCI Adapter is a USB 2.0 capable adapter that provides for the connection of one USB keyboard and mouse.

Limitation: Limited to USB 1.1 support with AIX

  • Attributes provided: USB Keyboard/Mouse Attachment
  • Attributes required: One available PCI slot
  • For 9125-F2A: (#2738)
    • Minimum required: 0
    • Maximum allowed: 6 (Initial order maximum: 6)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#2849) POWER GXT135P Graphics Accelerator with Digital Support

(No Longer Available as of November 27, 2009)

The POWER GXT135P is a versatile, low-priced 2D graphics accelerator for RS/6000 workstations and pSeries servers. It can be configured to operate in either 8-bit or 24-bit color modes. This adapter supports both analog and digital monitors. Its predecessor, Feature Number 2848, supported only analog monitors.

  • Hardware Description
    • 128-bit graphics processor
    • 8-bit CLUT or 24-bit true color
    • 16 MB SDRAM
    • 32-bit PCI interface
    • Universal PCI (5.0v or 3.3v)
    • 1 hardware color map
  • Features Supported
    • Up to approximately 16.7 million colors
    • Rectangular clipping
    • 2 analog monitor outputs at up to 1280 x 1024 resolution
    • 1 analog monitor output at up to 2048 x 1536 resolution
    • 1 digital monitor output at up to 1600 x 1200 resolution
    • 60 to 85 Hz refresh rates (ISO 9241, Part 3)
  • APIs Supported
    • X-Windows and Motif
    • UMS 2.3.0 (no hardware scaling)
  • Software Requirements
    • The total number of Graphics Adapters in any one partition may not exceed four.
  • Attributes provided: 2D Graphics
  • Attributes required: 1 PCI slot
  • For 9125-F2A: (#2849)
    • Minimum required: 0
    • Maximum allowed: 6 (Initial order maximum: 6)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#2861) ARTIC960Hx 4-Port EIA-232 Cable

  • Attributes provided: 4-port EIA-232 cable for (#2947)
  • Attributes required: One #2947 adapter
  • For 9125-F2A: (#2861)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 0)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Supported
    • CSU: No
    • Return parts MES: No

(#2863) ARTIC960Hx 4-Port X.21 Cable

  • Attributes provided: 4-port X.21 cable for (#2947)
  • Attributes required: One #2947 adapter
  • For 9125-F2A: (#2863)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 0)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Supported
    • CSU: No
    • Return parts MES: No

(#2864) ARTIC960Hx 4-Port V.35 (DTE) Cable

  • Attributes provided: 4-port X.35 (DTE) cable for (#2947)
  • Attributes required: One #2947 adapter
  • For 9125-F2A: (#2864)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 0)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Supported
    • CSU: No
    • Return parts MES: No

(#2934) 3M Asynchronous Terminal/Printer Cable EIA-232

The Asynchronous Printer/Terminal Cable is used for attaching printers, plotters, and terminals that support the EIA-232 standard to any asynchronous adapter. This cable is the equivalent of the combination of FC 2936 (modem cable) and FC 2937 (printer/terminal interposer) and replaces this method of printer/terminal attachment.

This cable is 3m (9.8 feet) long, uses DB25 connectors and is supported on all RS/6000 systems using any asynchronous ports. It is used in conjunction with:

  • FC 2931 (8-port Async Adapter EIA232, ISA bus)
  • FC 8133 (RJ45-DB25 converter cable for 16-port RANs 8130, 8134, 8136)
  • Attributes provided: EIA232 device attachment capability
  • Attributes required: Any RS/6000 Asynchronous port
  • For 9125-F2A: (#2934)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#2936) Asynchronous Cable EIA-232/V.24 3M

Used to attach a modem to the standard I/O ports with the 10-pin to 25-pin converter cable (#3925), 8-port Cable Assembly, 16-Port Cable Assembly, 16-Port Asynchronous Concentrator (with RJ-45 to DB-25 Converter Cable feature #6402) or the 16-Port EIA-232 Remote Async Node (with RJ45 to DB25 Converter Cable feature #8133). The cable is 3 meters (9.8 feet) in length.

  • Attributes provided: Modem attachment to async or serial port
  • Attributes required: Async or serial port
  • For 9125-F2A: (#2936)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#2943) 8-Port Asynchronous Adapter EIA-232/RS-422, PCI bus

(No Longer Available as of November 27, 2009)

For connection of up to 8 asynchronous EIA-232 or RS-422 devices. All eight ports are software programmable to support either EIA-232E or RS-422A protocols, at up to 230K baud.

  • Attributes provided: 8 Async ports
  • Attributes required: One PCI slot
  • For 9125-F2A: (#2943)
    • Minimum required: 0
    • Maximum allowed: 18 (Initial order maximum: 18)
    • OS level required: AIX support only
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#2947) IBM ARTIC960Hx 4-Port Multiprotocol PCI Adapter

The IBM ARTIC960Hx 4-Port Selectable PCI Adapter (#2947) is a one- slot, standard length, 32-bit PCI card. The adapter provides 4-Ports of: EIA-232, EIA530, RS-449, X.21, or V.35. Each port will support speeds of up 2.0M bps. Software support is provided by ARTIC960 Support for AIX Developer's Kit.

  • Attributes provided: One to four WAN connections at up to 2.0Mbps
  • Attributes required: One full length 32-bit PCI slot
  • For 9125-F2A: (#2947)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 0)
    • OS level required: AIX support only
    • Initial Order/MES/Both/Supported: Supported
    • CSU: No
    • Return parts MES: No

(#2951) Cable, V.24 / EIA-232

V.24 cable for use with #2962 - 2-Port Multiprotocol Adapter. Maximum of two cables per #2962.

  • Attributes provided: V.24 Cable
  • Attributes required: #2962 Adapter
  • For 9125-F2A: (#2951)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 0)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Supported
    • CSU: No
    • Return parts MES: No

(#2952) Cable, V.35

V.35 cable for use with #2962 - 2-Port Multiprotocol Adapter. Maximum of two cables per #2962.

  • Attributes provided: V.35 Cable
  • Attributes required: #2962 Adapter
  • For 9125-F2A: (#2952)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 0)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Supported
    • CSU: No
    • Return parts MES: No

(#2953) Cable, V.36 / EIA-499

V.36/EIA-499 cable for use with #2962 - 2-Port Multiprotocol Adapter. Maximum of two cables per #2962.

  • Attributes provided: V.36 Cable
  • Attributes required: #2962 Adapter
  • For 9125-F2A: (#2953)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 0)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Supported
    • CSU: No
    • Return parts MES: No

(#2954) Cable, X.21

X.21 cable for use with #2962 - 2-Port Multiprotocol Adapter. Maximum of two cables per #2962.

  • Attributes provided: X.21 Cable
  • Attributes required: #2962 Adapter
  • For 9125-F2A: (#2954)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 0)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Supported
    • CSU: No
    • Return parts MES: No

(#2962) 2-Port Multiprotocol PCI Adapter

This adapter provides high-speed connections between stand-alone system units on a WAN. To access WAN lines, the 2-Port Multiprotocol PCI Adapter connects via external communications equipment including Channel Service Units (CSU), Data Service Units (DSU), or through synchronous modems.

This adapter together with IBM AIXlink/X.25 provides a two-port connection to X.25 packet switched networks. IBM AIXlink/X.25 is a separately orderable LPP (5696-926).

2-Port Multiprotocol PCI Adapter with an appropriate cable is compatible with:

  • X.21 DCE - Using 2-Port Cable, X.21 (#2954)
    • CCITT X.21 Signalling
    • CCITT V.11 Electrical
    • CCITT X.27 Electrical
    • EIA-422-A Electrical
    • ISO 4903 Connector for DCE side of an X.21 VHSI Modem Cable
  • V.24 DCE - Using 2-Port Cable, V.24/EIA-232 (#2951)
    • CCITT V.24 Signalling
    • CCITT V.28 Electrical
    • CCITT X.21bis Electrical and Signalling
    • EIA-232-C Electrical and Signalling
    • ISO 2110 Connector for DCE side of an V.24 VHSI Modem Cable
  • V.35 DCE - Using 2-Port Cable, V.35 (#2952)
    • CCITT V.35 Some signals for signalling
    • CCITT V.28 Some signals for electrical and signalling
    • ISO 2593 Connector for DCE side of an V.35 VHSI Modem Cable
  • V.36 DCE - Using 2-Port Cable, V.36/EIA-449 (#2953)
    • CCITT V.10 Electrical
    • CCITT V.11 Electrical
  • Attributes provided: Two high speed WAN connections
  • Attributes required: One PCI slot
  • For 9125-F2A: (#2962)
    • Minimum required: 0
    • Maximum allowed: 20 (Initial order maximum: 0)
    • OS level required: AIX support only
    • Initial Order/MES/Both/Supported: Supported
    • CSU: No
    • Return parts MES: No

(#3125) Serial-to-Serial Port Cable for Rack/Rack

This 8 meter cable is available to provide a null-modem connection between the serial ports of two system drawers that are mounted in separate racks. The cable provides a DB25 female connector at each end.

  • Attributes provided: None
  • Attributes required: None
  • For 9125-F2A: (#3125)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#3158) 36.4 GB 10,000 RPM Ultra3 SCSI Disk Drive Assembly

The 36.4GB 10,000 RPM Ultra3 SCSI Disk Drive Assembly provides 36.4GB of storage capacity and supports the industry standard Ultra3 SCSI interface speed of up to 160 MBps.

Characteristics:

  • Form Factor: 3.5-inch, 1-inch (25 mm) high
  • Cable included: No
  • External Interface: Ultra3 SCSI (16-bit, Low Voltage Differential)
  • Attachment Industry Spec: SCSI-3 fast 80
  • Average Seek Time: 6.02 ms (based on four(4) READS to one(1) WRITE)
  • Average Latency: 2.99 ms
  • Rotational Speed: 10,000 RPM
  • Maximum Data Transfer Rate: 44.3 MBps

Limitation: This disk drive requires attachment to a supported Ultra3 SCSI Adapter in an system that supports an Ultra3 SCSI cable/ backplane in order for the drive to run at 160MBps. Also, any and all other SCSI devices on the same SCSI bus must also be Ultra2 or Ultra3 SCSI device(s) in order for this disk drive to run at 160MBps.

  • Attributes provided: 36.4GB of disk storage mounted in a carrier.
  • Attributes required: One disk drive bay.
  • For 9125-F2A: (#3158)
    • Minimum required: 0
    • Maximum allowed: 16 (Initial order maximum: 0)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Supported
    • CSU: No
    • Return parts MES: No

(#3159) 73.4 GB 10,000 RPM Ultra3 SCSI Disk Drive Assembly

The 73.4 GB 10,000 RPM Ultra3 SCSI Disk Drive Assembly provides 73.4 GB of storage capacity and supports the industry standard Ultra3 SCSI interface speed of up to 160 MBps.

Characteristics:

  • Form Factor: 3.5-inch, 1-inch (25 mm) high
  • Cable included: No
  • External Interface: Ultra3 SCSI (16-bit, Low Voltage Differential)
  • Attachment Industry Spec: SCSI-3 fast 80
  • Average Seek Time: 5.38 ms (based on four(4) READS to one(1) WRITE)
  • Average Latency: 3.00 ms
  • Rotational Speed: 10,000 RPM
  • Maximum Data Transfer Rate: 83.88 MBps

Limitation: This disk drive requires attachment to a supported Ultra3 SCSI Adapter in an system that supports an Ultra3 SCSI cable/ backplane in order for the drive to run at 160MBps. Also, any and all other SCSI devices on the same SCSI bus must also be Ultra2 or Ultra3 SCSI device(s) in order for this disk drive to run at 160MBps.

  • Attributes provided: 73.4 GB of disk storage mounted in a carrier.
  • Attributes required: One disk drive bay.
  • For 9125-F2A: (#3159)
    • Minimum required: 0
    • Maximum allowed: 16 (Initial order maximum: 0)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Supported
    • CSU: No
    • Return parts MES: No

(#3274) 73.4 GB 10,000 RPM Ultra320 SCSI Disk Drive Assembly

The 73.4 GB 10,000 RPM Ultra320 SCSI Disk Drive Assembly provides 73.4 GB of storage capacity and supports the industry standard Ultra320 SCSI interface speed of up to 320 MBps.

Characteristics:

  • Form Factor: 3.5-inch, 1-inch (25 mm) high
  • Cable included: No
  • External Interface: Ultra320 SCSI (16-bit, Low Voltage Differential)
  • Attachment Industry Spec: SCSI U320
  • Average Seek Time: 4.82 ms (based on four(4) READS to one(1) WRITE)
  • Average Latency: 2.99 ms
  • Rotational Speed: 10,000 RPM
  • Maximum Data Transfer Rate: 67 MBps

Limitation: This disk drive requires attachment to a supported Ultra320 SCSI Adapter in an system that supports an Ultra320 SCSI cable/backplane in order for the drive to run at 320 MBps. Also, any and all other SCSI devices on the same SCSI bus must also be Ultra2, Ultra3, or Ultra320 SCSI device(s) in order for this disk drive to run at 320 MBps.

  • Attributes provided: 73.4 GB of disk storage mounted in a carrier.
  • Attributes required: One disk drive bay.
  • For 9125-F2A: (#3274)
    • Minimum required: 0
    • Maximum allowed: 16 (Initial order maximum: 0)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Supported
    • CSU: No
    • Return parts MES: No

(#3275) 146.8 GB 10,000 RPM Ultra320 SCSI Disk Drive Assembly

The 146.8 GB 10,000 RPM Ultra320 SCSI Disk Drive Assembly provides 146.8 GB of storage capacity and supports the industry standard Ultra320 SCSI interface speed of up to 320 MBps.

Characteristics:

  • Form Factor: 3.5-inch, 1-inch (25 mm) high
  • Cable included: No
  • External Interface: Ultra320 SCSI (16-bit, Low Voltage Differential)
  • Attachment Industry Spec: SCSI U320
  • Average Seek Time: 4.94 ms (based on four(4) READS to one(1) WRITE)
  • Average Latency: 2.99 ms
  • Rotational Speed: 10,000 RPM
  • Maximum Data Transfer Rate: 67 MBps

Limitation: This disk drive requires attachment to a supported Ultra320 SCSI Adapter in a system that supports an Ultra320 SCSI cable/ backplane in order for the drive to run at 320 MBps. Also, any and all other SCSI devices on the same SCSI bus must also be Ultra2, Ultra3, or Ultra320 SCSI device(s) in order for this disk drive to run at 320 MBps.

  • Attributes provided: 146.8 GB of disk storage mounted in a carrier.
  • Attributes required: One disk drive bay.
  • For 9125-F2A: (#3275)
    • Minimum required: 0
    • Maximum allowed: 16 (Initial order maximum: 0)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Supported
    • CSU: No
    • Return parts MES: No

(#3277) 36.4 GB 15,000 RPM Ultra320 SCSI Disk Drive Assembly

The 36.4 GB 15,000 RPM Ultra320 SCSI Disk Drive Assembly provides 36.4 GB of storage capacity and supports the industry standard Ultra3 SCSI interface speed of up to 320 MBps.

Characteristics:

  • Form Factor: 3.5-inch, 1-inch (25 mm) high
  • Cable included: No
  • External Interface: Ultra320 SCSI (16-bit, Low Voltage Differential)
  • Attachment Industry Spec: SCSI U320
  • Average Seek Time: 3.7 ms (based on four(4) READS to one(1) WRITE)
  • Average Latency: 2 ms
  • Rotational Speed: 15,000 RPM
  • Maximum Data Transfer Rate: 83 MBps

Limitation: This disk drive requires attachment to a supported Ultra320 SCSI Adapter in a system that supports an Ultra320 SCSI cable/ backplane in order for the drive to run at 320 MBps. Also, any and all other SCSI devices on the same SCSI bus must also be Ultra2, Ultra3, or Ultra320 SCSI device(s) in order for this disk drive to run at 320 MBps.

  • Attributes provided: 36.4 GB of disk storage mounted in a carrier.
  • Attributes required: One disk drive bay.
  • For 9125-F2A: (#3277)
    • Minimum required: 0
    • Maximum allowed: 16 (Initial order maximum: 0)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Supported
    • CSU: No
    • Return parts MES: No

(#3278) 73.4 GB 15,000 RPM Ultra320 SCSI Disk Drive Assembly

The 73.4 GB 15,000 RPM Ultra320 SCSI Disk Drive Assembly provides 73.4 GB of storage capacity and supports the industry standard Ultra3 SCSI interface speed of up to 320 MBps.

Characteristics:

  • Form Factor: 3.5-inch, 1-inch (25 mm) high
  • Cable included: No
  • External Interface: Ultra320 SCSI (16-bit, Low Voltage Differential)
  • Attachment Industry Spec: SCSI U320
  • Average Seek Time: 3.7 ms (based on four(4) READS to one(1) WRITE)
  • Average Latency: 2 ms
  • Rotational Speed: 15,000 RPM
  • Maximum Data Transfer Rate: 83 MBps

Limitation: This disk drive requires attachment to a supported Ultra320 SCSI Adapter in a system that supports an Ultra320 SCSI cable/ backplane in order for the drive to run at 320 MBps. Also, any and all other SCSI devices on the same SCSI bus must also be Ultra2, Ultra3, or Ultra320 SCSI device(s) in order for this disk drive to run at 320 MBps.

  • Attributes provided: 73.4 GB of disk storage mounted in a carrier.
  • Attributes required: One disk drive bay.
  • For 9125-F2A: (#3278)
    • Minimum required: 0
    • Maximum allowed: 16 (Initial order maximum: 16)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Supported
    • CSU: No
    • Return parts MES: No

(#3279) 146.8 GB 15,000 RPM Ultra320 SCSI Disk Drive Assembly

(No Longer Available as of August 28, 2009)

The 146.8 GB 15,000 RPM Ultra320 SCSI Disk Drive Assembly provides 146.8 GB of storage capacity and supports the industry standard Ultra3 SCSI interface speed of up to 320 MBps.

Characteristics:

  • Form Factor: 3.5-inch, 1-inch (25 mm) high
  • Cable included: No
  • External Interface: Ultra320 SCSI (16-bit, Low Voltage Differential)
  • Attachment Industry Spec: SCSI U320
  • Average Seek Time: 3.7 ms (based on four(4) READS to one(1) WRITE)
  • Average Latency: 2 ms
  • Rotational Speed: 15,000 RPM
  • Maximum Data Transfer Rate:107 MBps

Limitation: This disk drive requires attachment to a supported Ultra320 SCSI Adapter in a system that supports an Ultra320 SCSI cable/ backplane in order for the drive to run at 320 MBps. Also, any and all other SCSI devices on the same SCSI bus must also be Ultra2, Ultra3, or Ultra320 SCSI device(s) in order for this disk drive to run at 320 MBps.

  • Attributes provided: 146.8 GB of disk storage mounted in a carrier.
  • Attributes required: One disk drive bay.
  • For 9125-F2A: (#3279)
    • Minimum required: 0
    • Maximum allowed: 16 (Initial order maximum: 16)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#3291) 10 Meter QSFP-4x Optical Cable

(No Longer Available as of July 29, 2011)

This 10 meter QSFP (Quad Small Form-factor Pluggable) to 4x Optical cable is used to connect the #5612 (Dual 2 Port 4x Host Channel Adapter) to supported InfiniBand switches.

  • For 9125-F2A: (#3291)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#3292) 20 meter QSFP-4x Optical Cable

(No Longer Available as of July 29, 2011)

This 20 meter QSFP (Quad Small Form-factor Pluggable) to 4x Optical cable is used to connect the #5612 (Dual 2 Port 4x Host Channel Adapter) to supported InfiniBand switches.

  • For 9125-F2A: (#3292)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#3294) 40 meter QSFP-4x Optical Cable

(No Longer Available as of January 7, 2011)

This 40 meter QSFP (Quad Small Form-factor Pluggable) to 4x Optical cable is used to connect the #5612 (Dual 2 Port 4x Host Channel Adapter) to supported InfiniBand switches.

  • For 9125-F2A: (#3294)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#3578) 300 GB 10,000 RPM Ultra320 SCSI Disk Drive Assembly

The 300 GB 10,000 RPM Ultra320 SCSI Disk Drive Assembly provides 300 GB of storage capacity and supports the industry standard Ultra320 SCSI interface speed of up to 320 MBps.

Characteristics:

  • Form Factor: 3.5-inch, 1-inch (25 mm) high
  • Cable included: No
  • External Interface: Ultra320 SCSI (16-bit, Low Voltage Differential)
  • Attachment Industry Spec: SCSI U320
  • Average Seek Time: 4.9 ms (based on four(4) READS to one(1) WRITE)
  • Average Latency: 2.99 ms
  • Rotational Speed: 10,000 RPM
  • Maximum Data Transfer Rate: 88 MBps

Limitation: This disk drive requires attachment to a supported Ultra320 SCSI Adapter in a system that supports an Ultra320 SCSI cable/ backplane in order for the drive to run at 320 MBps. Also, any and all other SCSI devices on the same SCSI bus must also be Ultra2, Ultra3, or Ultra320 SCSI device(s) in order for this disk drive to run at 320 MBps.

  • Attributes provided: 300 GB of disk storage mounted in a carrier.
  • Attributes required: One disk drive bay.
  • For 9125-F2A: (#3578)
    • Minimum required: 0
    • Maximum allowed: 16 (Initial order maximum: 0)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Supported
    • CSU: No
    • Return parts MES: No

(#3585) 300 GB 15K RPM SCSI Disk Drive

The 300 GB 15,000 RPM Ultra320 SCSI Disk Drive Assembly provides 300 GB of storage capacity and supports the industry standard Ultra3 SCSI interface speed of up to 320 MBps.

Characteristics:

  • Form Factor: 3.5-inch, 1-inch (25 mm) high
  • Cable included: No
  • External Interface: Ultra320 SCSI (16-bit, Low Voltage Differential)
  • Attachment Industry Spec: SCSI U320
  • Average Seek Time: 3.7 ms (based on four(4) READS to one(1) WRITE)
  • Average Latency: 2 ms
  • Rotational Speed: 15,000 RPM
  • Maximum Data Transfer Rate:107 MBps

Limitation: This disk drive requires attachment to a supported Ultra320 SCSI Adapter in a system that supports an Ultra320 SCSI cable/ backplane in order for the drive to run at 320 MBps. Also, any and all other SCSI devices on the same SCSI bus must also be Ultra2, Ultra3, or Ultra320 SCSI device(s) in order for this disk drive to run at 320 MBps.

  • Attributes provided: 300 GB of disk storage
  • Attributes required: one disk drive bay
  • For 9125-F2A: (#3585)
    • Minimum required: 0
    • Maximum allowed: 16 (Initial order maximum: 16)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Supported
    • CSU: No
    • Return parts MES: No

(#3586) - 69GB 3.5" SAS Solid State Drive

(No Longer Available as of July 14, 2009)

The 69GB 3.5" SAS Solid State Drive (SSD) provides 69.7 GB of very high performance storage, much faster than spinning disk drives with their delays due to positioning the disk arm and waiting for the spinning disk to rotate under the arm. SSD also provide lower power utilization than spinning or hard disk drives (HDD). The drive is formatted to 69.7 GB and can be used by AIX, Linux (#3586) and IBM i (#3587). Both are identical drives, but have different feature codes to help the IBM configuration tools understand how the SSD is used.

  • Connector - standard SAS dual port
  • 3Gb/sec SAS device (300 MB/sec)
  • 528 bytes sectors Power System
  • Attributes provided: 69.7GB of formatted drive storage mounted in a 3.5? carrier
  • Attributes required: One 3.5-inch SAS drive bay slot in the #5886 EXP 12S SAS Disk Drawer or 8234-EMA/9117-MMA CEC
  • For 9125-F2A: (#3586)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

    Note: Each #5886 supports up to eight #3586 SSD and the remaining 4 slots must remain empty.

(#3646) 73 GB 15K RPM SAS Disk Drive

(No Longer Available as of November 28, 2008)

73.4 GB Serial Attached SCSI (SAS) DASD device, in a carrier capable of providing Hot Swap support. Provides 73.4 GB of storage capacity. Supports the industry standard SAS interface. Can be used only in a drawer/system designed to support the SAS interface.

Characteristics:

  • Form Factor: 3.5 inch Form Factor, 1 inch drive.
  • Cable included: No
  • External Interface: standard SAS Dual Port
  • Rotational Speed: 15,000 RPM
  • Interface Speed: 300 MB/sec.
  • Format: 512 Bytes/sector default, 528 Bytes/sector possible with reformat.
  • Attributes provided: 73.4 GB of disk storage mounted in a carrier.
  • Attributes required: one disk drive bay
  • For 9125-F2A: (#3646)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#3647) 146 GB 15K RPM SAS Disk Drive

(No Longer Available as of July 14, 2009)

146.8 GB Serial Attached SCSI (SAS) DASD device, in a carrier capable of providing Hot Swap support. Provides 146.8 GB of storage capacity. Supports the industry standard SAS SCSI interface. Can be used only in a drawer/system designed to support the SAS SCSI interface.

Characteristics:

  • Form Factor: 3.5 inch Form Factor, 1 inch drive.
  • Cable included: No
  • External Interface: standard SAS Dual Port
  • Rotational Speed: 15,000 RPM
  • Interface Speed: 300 MB/sec.
  • Format: 512 Bytes/sector default, 528 Bytes/sector possible with reformat.
  • Attributes provided: 146.8 GB of Disk Storage mounted in a carrier
  • Attributes required: one SAS Drive Slot
  • For 9125-F2A: (#3647)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#3648) 300 GB 15K RPM SAS Disk Drive

(No Longer Available as of July 14, 2009)

300 GB Serial Attached SCSI (SAS) DASD device, in a carrier capable of providing Hot Swap support. Provides 300 GB of storage capacity. Supports the industry standard SAS SCSI interface. Can be used only in a drawer/system designed to support the SAS SCSI interface.

Characteristics:

  • Form Factor: 3.5 inch Form Factor, 1 inch drive.
  • Cable included: No
  • External Interface: standard SAS Dual Port
  • Rotational Speed: 15,000 RPM
  • Interface Speed: 300 MB/sec.
  • Format: 512 Bytes/sector default, 528 Bytes/sector possible with reformat.
  • Attributes provided: 300 GB of Disk Storage mounted in a carrier
  • Attributes required: one SAS Drive Slot
  • For 9125-F2A: (#3648)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#3649) 450GB 15K RPM SAS Disk Drive

(No Longer Available as of July 14, 2009)

Attached SAS DASD device, in a carrier capable of providing Hot Swap support. Provides 450GB of storage capacity. Supports the industry standard SAS interface. Can be used only in a drawer/system designed to support the SAS interface.

Characteristics:

  • Form Factor: 3.5 inch Form Factor, 1 inch drive.
  • Cable included: No
  • External Interface: standard SAS Dual Port
  • Rotational Speed: 15,000 RPM
  • Interface Speed: 300 MB/sec.
  • Format: 512 Bytes/sector default, 528 Bytes/sector possible with re- format.
  • Attributes provided: 450GB of disk storage mounted in a carrier.
  • Attributes required: one SAS disk drive bay
  • For 9125-F2A: (#3649)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: Refer to "Software Requirements" in Sales Manual.
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#3652) SAS Cable (EE) Drawer to Drawer 1M

(No Longer Available as of July 14, 2009)

SAS Cable (EE), connects a second SAS disk drawer to a primary SAS disk drawer attached to a SAS controller adaper. This cable has one Mini SAS 4x cable plug connector on each end. Both connectors must be attached to an ENCLOSURE UP Arrow port on the ESM module of the attaching drawers. Follow the directions on the connector labels when attaching the connectors on this cable. This cable supports both Single and Dual path configurations. All supported configurations require two of this feature to attach a secondary disk drawer to the primary disk drawer. The length of this cable is 1 meter. Choose the SAS (EE) cable length to match the distance between the two SAS drawers.

  • Attributes provided: SAS Disk drawer to SAS Disk drawer attach cable
  • Attributes required: Primary SAS Disk drawer properly configured
  • For 9125-F2A: (#3652)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#3653) SAS Cable (EE) Drawer to Drawer 3M

(No Longer Available as of July 14, 2009)

SAS Cable (EE), connects a second SAS disk drawer to a primary SAS disk drawer attached to a SAS controller adaper. This cable has one Mini SAS 4x cable plug connector on each end. Both connectors must be attached to an ENCLOSURE UP Arrow port on the ESM module of the attaching drawers. Follow the directions on the connector labels when attaching the connectors on this cable. This cable supports both Single and Dual path configurations. All supported configurations require two of this feature to attach a secondary disk drawer to the primary disk drawer. The length of this cable is 3 meter. Choose the SAS (EE) cable length to match the distance between the two SAS drawers.

  • Attributes provided: SAS Disk drawer to SAS Disk drawer attach cable
  • Attributes required: Primary SAS Disk drawer properly configured
  • For 9125-F2A: (#3653)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#3654) SAS Cable (EE) Drawer to Drawer 6M

(No Longer Available as of July 14, 2009)

SAS Cable (EE), connects a second SAS disk drawer to a primary SAS disk drawer attached to a SAS controller adaper. This cable has one Mini SAS 4x cable plug connector on each end. Both connectors must be attached to an ENCLOSURE UP Arrow port on the ESM module of the attaching drawers. Follow the directions on the connector labels when attaching the connectors on this cable. This cable supports both Single and Dual path configurations. All supported configurations require two of this feature to attach a secondary disk drawer to the primary disk drawer. The length of this cable is 6 meter. Choose the SAS (EE) cable length to match the distance between the two SAS drawers.

  • Attributes provided: SAS Disk drawer to SAS Disk drawer attach cable
  • Attributes required: Primary SAS Disk drawer properly configured
  • For 9125-F2A: (#3654)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#3661) SAS Cable (X) Adapter to SAS Enclosure, Dual Controller/Dual

(No Longer Available as of July 14, 2009)

Path 3M This SAS cable (X) connects a SAS disk drawer to two SAS controller adapters. This cable supports dual controller/dual path attach between two SAS controller adapters and the SAS disk drawer. The SAS controller adapters can be in the same or in different host systems. This cable has four Mini SAS 4x plug connectors. Two of the Mini SAS 4x plug connectors attach to the adapters and are keyed as END DEVICES. Two of the Mini SAS 4x plug connectors attach to the SAS disk drawer and are keyed for ENCLOSURE DOWN Arrow. All of the connectors are wired in 2x mode. Follow the directions on the connector labels when attaching the connectors on this cable. This cable is 3 meters long, choose the SAS (X) cable length that matches the distance between the adapters and the SAS disk drawer. The adapter legs of this cable are each 2.5 meters long.

  • Attributes provided: connection between two SAS controller adapters and a SAS disk drawer
  • Attributes required: two SAS controller adapters and a SAS disk drawer
  • For 9125-F2A: (#3661)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#3662) SAS Cable (X) Adapter to SAS Enclosure, Dual Controller/Dual

(No Longer Available as of July 14, 2009)

Path 6M This SAS cable (X) connects a SAS disk drawer to two SAS controller adapters. This cable supports dual controller/dual path attach between two SAS controller adapters and the SAS disk drawer. The SAS controller adapters can be in the same or in different host systems. This cable has four Mini SAS 4x plug connectors. Two of the Mini SAS 4x plug connectors attach to the adapters and are keyed as END DEVICES. Two of the Mini SAS 4x plug connectors attach to the SAS disk drawer and are keyed for ENCLOSURE DOWN Arrow. All of the connectors are wired in 2x mode. Follow the directions on the connector labels when attaching the connectors on this cable. This cable is 6 meters long, choose the SAS (X) cable length that matches the distance between the adapters and the SAS disk drawer. The adapter legs of this cable are each 5.5 meters long.

  • Attributes provided: connection between two SAS controller adapters and a SAS disk drawer
  • Attributes required: two SAS controller adapters and a SAS disk drawer
  • For 9125-F2A: (#3662)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#3663) SAS Cable (X) Adapter to SAS Enclosure, Dual Controller/Dual

(No Longer Available as of July 14, 2009)

Path 15M This SAS cable (X) connects a SAS disk drawer to two SAS controller adapters. This cable supports dual controller/dual path attach between two SAS controller adapters and the SAS disk drawer. The SAS controller adapters can be in the same or in different host systems. This cable has four Mini SAS 4x plug connectors. Two of the Mini SAS 4x plug connectors attach to the adapters and are keyed as END DEVICES. Two of the Mini SAS 4x plug connectors attach to the SAS disk drawer and are keyed for ENCLOSURE DOWN Arrow. All of the connectors are wired in 2x mode. Follow the directions on the connector labels when attaching the connectors on this cable. This cable is 15 meters long, choose the SAS (X) cable length that matches the distance between the adapters and the SAS disk drawer. The adapter legs of this cable are each 14.5 meters long.

  • Attributes provided: connection between two SAS controller adapters and a SAS disk drawer
  • Attributes required: two SAS controller adapters and a SAS disk drawer
  • For 9125-F2A: (#3663)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#3684) SAS Cable (AE) Adapter to Enclosure, single controller/single path 3M

(No Longer Available as of July 14, 2009)

This SAS cable (AE) connects a SAS Controller to a media expansion drawer. This cable can also be used to connect two SAS adapters to a SAS disk drawer in a specific dual controller HA two system JBOD configuration using two #5912 controllers. Single controller/single path connections are supported with this cable only for this specific JBOD configuration and as such, two #5912 SAS controllers and two (AE style) cables are required for a supported configuration. The two SAS adapters must be in different host systems/partitions. This cable has one Mini SAS 4X plug connector on the adapter end wired in 4x mode and one Mini SAS 4X plug connector on the drawer end , wired in 4x mode. Follow the directions on the connector labels when attaching the connectors on this cable. This cable is 3 meters long, select the SAS (AE) cable length that best matches the distance between the host system and the remote SAS drawer being attached.

  • Attributes provided: Connection between a SAS controller and a media expansion drawer or connection between #5912 SAS controller and a SAS disk drawer in a dual controller HA two system JBOD configuration only
  • Attributes required: SAS media expansion drawer or SAS disk drawer, and a SAS controller adapter
  • For 9125-F2A: (#3684)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#3685) SAS Cable (AE) Adapter to Enclosure, single controller/single path 6M

(No Longer Available as of July 14, 2009)

This SAS cable (AE) connects a SAS Controller to a media expansion drawer. This cable can also be used to connect two SAS adapters to a SAS disk drawer in a specific dual controller HA two system JBOD configuration using two #5912 controllers. Single controller/single path connections are supported with this cable only for this specific JBOD configuration and as such, two #5912 SAS controllers and two (AE style) cables are required for a supported configuration. The two SAS adapters must be in different host systems/partitions. This cable has one Mini SAS 4X plug connector on the adapter end wired in 4x mode and one Mini SAS 4X plug connector on the drawer end, wired in 4x mode. Follow the directions on the connector labels when attaching the connectors on this cable. This cable is 6 meters long, select the SAS (AE) cable length that best matches the distance between the host system and the remote SAS drawer being attached.

  • Attributes provided: Connection between a SAS controller and a media expansion drawer or connection between #5912 SAS controller and a SAS disk drawer in a dual controller HA two system JBOD configuration only
  • Attributes required: SAS media expansion drawer or SAS disk drawer, and a SAS controller adapter
  • For 9125-F2A: (#3685)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#3688) - SAS Cable (AT) 0.6 Meter

This 0.6 Meter SAS Cable (AT) is used to drive the 12X I/O Drawer Small Form Factor disk using PCIe SAS adapters installed in the drawer. If SFF disk is installed in the 12X I/O Drawer PCIe, SFF disk, then there must be at least one SAS AT cable assigned.

  • Attributes provided: 0.6 Meter SAS Cable (AT)
  • Attributes required: 12X I/O Drawer with a PCIe SAS adapter
  • For 9125-F2A: (#3688)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#3691) SAS Cable (YO) Adapter to SAS Enclosure, Single Controller/Dual

(No Longer Available as of July 14, 2009)

Path 1.5 M This SAS cable (YO) connects a remote SAS drawer to a SAS controller adapter. This cable supports single controller/dual path attach between the SAS controller adapter and the SAS disk drawer. This cable has one Mini SAS 4X plug connector on the adapter end keyed for an END DEVICE, wired in 4x mode and two Mini SAS 4X plug connectors on the drawer end keyed for ENCLOSURE DOWN Arrow, both are wired in 2x mode. Follow the directions on the connector labels when attaching the connectors on this cable. This cable is 1.5 meters long, choose the SAS (YO) cable length that matches the distance between the adapter and the SAS disk drawer.

  • Attributes provided: connection between SAS controller adapter and a SAS disk drawer
  • Attributes required: SAS controller adapter and a SAS disk drawer
  • For 9125-F2A: (#3691)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#3692) SAS Cable (YO) Adapter to SAS Enclosure, Single Controller/Dual

(No Longer Available as of July 14, 2009)

Path 3 M This SAS cable (YO) connects a remote SAS drawer to a SAS controller adapter. This cable supports single controller/dual path attach between the SAS controller adapter and the SAS disk drawer. This cable has one Mini SAS 4X plug connector on the adapter end keyed for an END DEVICE, wired in 4x mode and two Mini SAS 4X plug connectors on the drawer end keyed for ENCLOSURE DOWN Arrow, both are wired in 2x mode. Follow the directions on the connector labels when attaching the connectors on this cable. This cable is 3 meters long, choose the SAS (YO) cable length that matches the distance between the adapter and the SAS disk drawer.

  • Attributes provided: connection between SAS controller adapter and a SAS disk drawer
  • Attributes required: SAS controller adapter and a SAS disk drawer
  • For 9125-F2A: (#3692)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#3693) SAS Cable (YO) Adapter to SAS Enclosure, Single Controller/Dual

(No Longer Available as of July 14, 2009)

Path 6 M This SAS cable (YO) connects a remote SAS drawer to a SAS controller adapter. This cable supports single controller/dual path attach between the SAS controller adapter and the SAS disk drawer. This cable has one Mini SAS 4X plug connector on the adapter end keyed for an END DEVICE, wired in 4x mode and two Mini SAS 4X plug connectors on the drawer end keyed for ENCLOSURE DOWN Arrow, both are wired in 2x mode. Follow the directions on the connector labels when attaching the connectors on this cable. This cable is 6 meters long, choose the SAS (YO) cable length that matches the distance between the adapter and the SAS disk drawer.

  • Attributes provided: connection between SAS controller adapter and a SAS disk drawer
  • Attributes required: SAS controller adapter and a SAS disk drawer
  • For 9125-F2A: (#3693)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#3694) SAS Cable (YO) Adapter to SAS Enclosure, Single Controller/Dual

(No Longer Available as of July 14, 2009)

Path 15 M This SAS cable (YO) connects a remote SAS drawer to a SAS controller adapter. This cable supports single controller/dual path attach between the SAS controller adapter and the SAS disk drawer. This cable has one Mini SAS 4X plug connector on the adapter end keyed for an END DEVICE, wired in 4x mode and two Mini SAS 4X plug connectors on the drawer end keyed for ENCLOSURE DOWN Arrow, both are wired in 2x mode. Follow the directions on the connector labels when attaching the connectors on this cable. This cable is 15 meters long, choose the SAS (YO) cable length that matches the distance between the adapter and the SAS disk drawer.

  • Attributes provided: connection between SAS controller adapter and a SAS disk drawer
  • Attributes required: SAS controller adapter and a SAS disk drawer
  • For 9125-F2A: (#3694)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#3759) Universal Lift Tool and Service Ladder

This feature delivers the Universal Lift Tool and Service Ladder for the 24" wide IBM servers.

#3759 is a feature that is available on multiple server types (Power 595, Power 575 and the System z10) Failure to have at least one #3759 available in a location may result in delayed or prolonged maintenance times

  • Attributes provided: Universal Lift Tool and Service Ladder
  • Attributes required: 24-inch wide IBM Server (Power 595, Power 575 or System z10)
  • For 9125-F2A: (#3759)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#3760) Universal Lift Tool Adapters for Power 575

This feature delivers the Universal Lift Tool Adapters required by the Power 575 to be used with the Universal Lift Tool (#3759).

Failure to have at least one #3760 available in a location may result in delayed or prolonged maintenance times

  • Attributes provided: Universal Lift Tool Adapters for the Power 575
  • Attributes required: Power 575 system
  • For 9125-F2A: (#3760)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#3925) 0.3M Serial Port Converter Cable, 9-Pin to 25-Pin

This cable converts the 9-pin serial port on the system to a 25-pin serial port which allows the user to attach 25-pin serial devices to the system.

  • Attributes provided: 9-Pin to 25-Pin connectivity
  • Attributes required: None
  • For 9125-F2A: (#3925)
    • Minimum required: 0
    • Maximum allowed: 48 (Initial order maximum: 48)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#3926) Asynch Printer/Terminal Cable, 9-pin to 25-pin, 4M

(No Longer Available as of July 29, 2011)

This 4-meter cable and transposer (2 parts) allows external async devices such as printers or terminals to be attached directly to the 9-pin serial port. Thisis equivalent to using #3925 in combination with #2934.

  • Attributes provided: None
  • Attributes required: None
  • For 9125-F2A: (#3926)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#3928) Serial Port Null Modem Cable, 9-pin to 9-pin, 10M

This 10 meter 9 pin to 9 pin Null Modem Serial cable allows two EIA-232 communications ports to exchange data with one another without going through a modem.

  • Attributes provided: 9 pin female connector at each end of the cable
  • For 9125-F2A: (#3928)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#4599) PCI Blind Swap Cassette Kit, Single Wide Adapters, Universal

This feature contains a blind swap cassette for single slot width PCI adapters. It also includes the necessary hardware to adapt the cassette to mount various sizes of PCI cards.

  • Attributes provided: Blind swap PCI cassette
  • Attributes required: PCI card and empty PCI adapter location
  • For 9125-F2A: (#4599)
    • Minimum required: 0
    • Maximum allowed: 99 (Initial order maximum: 0)
    • OS level required: None
    • Initial Order/MES/Both/Supported: MES
    • CSU: No
    • Return parts MES: No

(#4651) Rack Indicator, Rack #1

When added to an initial rack order, this indicator is used to specify the first rack for a multi rack order, or the only rack for a single rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #1.

Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed.

For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack Integration/ Rack Specify
  • Attributes required: Rack
  • For 9125-F2A: (#4651)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: Does not apply

(#4652) Rack Indicator, Rack #2

When added to an initial rack order, this indicator is used to specify the second rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #2 of a multi rack order.

Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed.

For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack Integration/Rack specify
  • Attributes required: Rack
  • For 9125-F2A: (#4652)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: Does not apply

(#4653) Rack Indicator, Rack #3

When added to an initial rack order, this indicator is used to specify the third rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #3 of a multi rack order.

Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed.

For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 9125-F2A: (#4653)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: Does not apply

(#4654) Rack Indicator, Rack #4

When added to an initial rack order, this indicator is used to specify the fourth rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #4 of a multi rack order.

Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed.

For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 9125-F2A: (#4654)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: Does not apply

(#4655) Rack Indicator, Rack #5

When added to an initial rack order, this indicator is used to specify the fifth rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #5 of a multi rack order.

Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed.

For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 9125-F2A: (#4655)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: Does not apply

(#4656) Rack Indicator, Rack #6

When added to an initial rack order, this indicator is used to specify the sixth rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #6 of a multi rack order.

Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed.

For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 9125-F2A: (#4656)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: Does not apply

(#4657) Rack Indicator, Rack #7

When added to an initial rack order, this indicator is used to specify the seventh rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #7 of a multi rack order.

Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed.

For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 9125-F2A: (#4657)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: Does not apply

(#4658) Rack Indicator, Rack #8

When added to an initial rack order, this indicator is used to specify the eighth rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #8 of a multi rack order.

Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed.

For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 9125-F2A: (#4658)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: Does not apply

(#4659) Rack Indicator, Rack #9

When added to an initial rack order, this indicator is used to specify the ninth rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #9 of a multi rack order.

Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed.

For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 9125-F2A: (#4659)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: Does not apply

(#4660) Rack Indicator, Rack #10

When added to an initial rack order, this indicator is used to specify the tenth rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #10 of a multi rack order.

Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed.

For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 9125-F2A: (#4660)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: Does not apply

(#4661) Rack Indicator, Rack #11

When added to an initial rack order, this indicator is used to specify the eleventh rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #11 of a multi rack order.

Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed.

For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 9125-F2A: (#4661)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: Does not apply

(#4662) Rack Indicator, Rack #12

When added to an initial rack order, this indicator is used to specify the twelfth rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #12 of a multi rack order.

Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed.

For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 9125-F2A: (#4662)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: Does not apply

(#4663) Rack Indicator, Rack #13

When added to an initial rack order, this indicator is used to specify the thirteenth rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #13 of a multi rack order.

Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed.

For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 9125-F2A: (#4663)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: Does not apply

(#4664) Rack Indicator, Rack #14

When added to an initial rack order, this indicator is used to specify the fourteenth rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #14 of a multi rack order.

Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed.

For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 9125-F2A: (#4664)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: Does not apply

(#4665) Rack Indicator, Rack #15

When added to an initial rack order, this indicator is used to specify the fifteenth rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #15 of a multi rack order.

Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed.

For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 9125-F2A: (#4665)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: Does not apply

(#4666) Rack Indicator, Rack #16

When added to an initial rack order, this indicator is used to specify the sixteenth rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #16 of a multi rack order.

Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed.

For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 9125-F2A: (#4666)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: Does not apply

(#4671) First Shared I/O Drawer, Indicator

#4671 is used to identify the connectivity and associativity when two nodes connect to the first shared I/O drawer in the rack. This enables the correct number of adapter slots and the correct number of disk bays to be assigned to each of the nodes. These indicators would be ordered on each of the nodes that connect to the first shared I/O drawer.

  • Attributes provided: Indicator of first shared I/O drawer.
  • Attributes required: Two nodes connecting to the first shared I/O drawer in a rack.
  • For 9125-F2A: (#4671)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: No

(#4672) Second Shared I/O Drawer, Indicator

#4672 is used to identify the connectivity and associativity when two nodes connect to the second shared I/O drawer in the rack. This enables the correct number of adapter slots and the correct number of disk bays to be assigned to each of the nodes. These indicators would be ordered on each of the nodes that connect to the second shared I/O drawer.

  • Attributes provided: Indicator of second shared I/O drawer.
  • Attributes required: Two nodes connecting to the second shared I/O drawer in a rack.
  • For 9125-F2A: (#4672)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: No

(#4673) Third Shared I/O Drawer, Indicator

#4673 is used to identify the connectivity and associativity when two nodes connect to the third shared I/O drawer in the rack. This enables the correct number of adapter slots and the correct number of disk bays to be assigned to each of the nodes. These indicators would be ordered on each of the nodes that connect to the third shared I/O drawer.

  • Attributes provided: Indicator of third shared I/O drawer.
  • Attributes required: Two nodes connecting to the third shared I/O drawer in a rack.
  • For 9125-F2A: (#4673)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: No

(#4674) Fourth Shared I/O Drawer, Indicator

#4674 is used to identify the connectivity and associativity when two nodes connect to the fourth shared I/O drawer in the rack. This enables the correct number of adapter slots and the correct number of disk bays to be assigned to each of the nodes. These indicators would be ordered on each of the nodes that connect to the fourth shared I/O drawer.

  • Attributes provided: Indicator of fourth shared I/O drawer.
  • Attributes required: Two nodes connecting to the fourth shared I/O drawer in a rack.
  • For 9125-F2A: (#4674)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: No

(#4764) PCI-X Cryptographic Coprocessor (FIPS 4)

(No Longer Available as of July 29, 2011)

Provides both cryptographic coprocessor and secure-key cryptographic accelerator functions in a single PCI-X card. The coprocessor functions are targeted to banking and finance applications. Financial PIN processing and Europay, MasterCard, Visa (EMV) credit card functions are provided. EMV is a standard for integrated-chip based credit cards. The secure-key accelerator functions are targeted to improving the performance of Secure Sockets Layer (SSL) transactions. The #4764 provides the security and performance required to support eBusiness and emerging digital signature applications. Host application access to the cryptographic services of the #4764 are via the Common Cryptographic Architecture (CCA) application programming interfaces (APIs) or additionally via Public-Key Cryptographic Standards (PKCS#11) APIs. Only one API can be loaded on a single feature 4764 card.

The #4764 provides secure storage of cryptographic keys in a tamper resistant hardware security module (HSM), which is designed to meet FIPS 140 security requirements. FIPS 140 is a U.S. Government National Instiute of Standards & Technology (NIST) administered standard and certification program for cryptographic modules.

Feature 4764 PCI-X Cryptographic Coprocessor (FIPS 4) users will be able to down load firmware for AIX from the following URL replacing the firmware CD previously provided.

Please refer to the following URL for the latest firmware and software updates:

http://www-03.ibm.com/security/cryptocards/
  • Attributes provided:
    • Cryptographic Accelerator Function
    • EMV-Based Credit Card Function
    • CCA API Host Support, and PKCS#11 API.
  • Attributes required:
    • One PCI-X card slot per 4764 FC.

      Note: Only one API (CCA or PKCS11 but not both) can be loaded per 4764 Feature.

  • For 9125-F2A: (#4764)
    • Minimum required: 0
    • Maximum allowed: 10 (Initial order maximum: 10)
    • OS level required: AIX support only
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#5005) Software Preinstall

(No Longer Available as of July 30, 2010)

Licensed programs may be preinstalled on the media selected. To order this option, specify code (#5005) on the initial system order. The preinstalled licensed programs will be at the same release level as programs being shipped from the Program Libraries at the time the system is manufactured.

  • Attributes provided: None
  • Attributes required: None
  • For 9125-F2A: (#5005)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: No

(#5612) Dual 2 Port 4x Host Channel Adapter

(No Longer Available as of July 29, 2011)

The #5612, Dual 2 Port 4x Host Channel Adapter, provides the attachment to supported InfiniBand switches. The adapter plugs into the GX bus slot of the 575. Connection to supported InfiniBand switches is accomplished by using the QSFP-4x Cables, #3291, #3292 or #3294. #5612 occupies the space of one PCI adapter within the server, reducing the available PCI slots by one, if the I/O Risers (#6389) feature is present.

  • Attributes provided: Dual 2 port 4X connections to attach to supported InfiniBand switches
  • Attributes required: Available GX slot within the 9125-F2A
  • For 9125-F2A: (#5612)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required:
      • AIX 5L for POWER V5.3 with the 5300-08 Technology Level
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#5680) Activation of 1GB DDR2 POWER6 Memory

(No Longer Available as of September 26, 2014)

Each occurrence of this feature will permanently activate 1 GB of DDR2, POWER6 memory.

  • Attributes provided: Activation on 1GB of DDR2 -POWER6 memory
  • Attributes required: inactive POWER6-DDR2 memory
  • For 9125-F2A: (#5680)
    • Minimum required: 0
    • Maximum allowed: 256 (Initial order maximum: 256)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#5681) Activation of 256 GB DDR2 POWER6 Memory

(No Longer Available as of September 26, 2014)

Each occurrence of this feature will permanently activate 256 GB of DDR2, POWER6 memory.

  • Attributes provided: Activation on 256 GB of DDR2 -POWER6 memory
  • Attributes required: 256 GB of inactive POWER6-DDR2 memory
  • For 9125-F2A: (#5681)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES:

(#5684) - Activation of 100 GB DDR2 Memory

(No Longer Available as of September 26, 2014)

Each occurrence of this feature will permanently activate 100 GB of DDR2 memory.

  • Attributes provided: Activation on 100 GB of DDR2 memory
  • Attributes required: 100 GB of inactive DDR2 memory
  • For 9125-F2A: (#5684)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#5687) 0/4GB (4X1GB) DIMMS, 533 MHz, DDR2, P6 CoD Memory

(No Longer Available as of July 29, 2011)

This CoD memory feature makes available 4 DIMMS each with 1 GB of memory for a total feature size of 4GB of DDR2, 533MHz POWER6 system memory. None of the memory in this feature is active. Feature #5680 must be purchased to activate the memory in this feature.

  • Attributes provided: 4GB of memory available on 4 DIMMS
  • Attributes required: 4 empty DIMM slots
  • For 9125-F2A: (#5687)
    • Minimum required: 0
    • Maximum allowed: 16 (Initial order maximum: 16)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#5688) 0/8GB (4X2GB) DIMMS, 533 MHz, DDR2, P6 CoD Memory

(No Longer Available as of July 29, 2011)

This CoD memory feature makes available 4 DIMMS each with 2 GB of memory for a total feature size of 8GB of DDR2, 533MHz POWER6 system memory. None of the memory in this feature is active. Feature #5680 must be purchased to activate the memory in this feature.

  • Attributes provided: 8GB of memory available on 4 DIMMS
  • Attributes required: 4 empty DIMM slots
  • For 9125-F2A: (#5688)
    • Minimum required: 0
    • Maximum allowed: 16 (Initial order maximum: 16)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#5698) 0/16GB (4X4GB) DIMMS, 533 MHz, DDR2, P6 CoD Memory

(No Longer Available as of July 29, 2011)

This CoD memory feature makes available 4 DIMMS each with 4 GB of memory for a total feature size of 16GB of DDR2, 533MHz POWER6 system memory. None of the memory in this feature is active. Feature #5680 must be purchased to activate the memory in this feature.

  • Attributes provided: 16GB of memory available on 4 DIMMS
  • Attributes required: 4 empty DIMM slots
  • For 9125-F2A: (#5698)
    • Minimum required: 0
    • Maximum allowed: 16 (Initial order maximum: 16)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#5700) IBM Gigabit Ethernet-SX PCI-X Adapter

(No Longer Available as of May 29, 2009)

The IBM Gigabit Ethernet-SX PCI-X Adapter provides a 1 Gbps (1000 Base-SX) full-duplex Ethernet LAN connection with throughput on a standard shortwave multimode optical cable which conforms to the IEEE 802.3z standard. The adapter supports distances of 260m for 62.5 micron Multi Mode Fiber (MMF) and 550m for 50.0 micron MMF. AIX Network Install Manager (NIM) boot capability is supported with this adapter.

Note: For optimum performance, the adapter should be placed in a 64 bit PCI-X card slot.

Note: The IBM Gigabit Ethernet-SX PCI-X Adapter (#5700) incorporates an LC type connector on the card. This new, smaller form factor connector is being used by the industry for the next generation of fiber optic networks. If connecting into an older, existing SC type connector network, an LC-SC 62.5 Micron Fiber Converter Cable (#2459) or LC-SC 50 Micron Fiber Converter Cable (#2456) is required.

Limitation: Half Duplex (HDX) mode is not supported.

  • Attributes provided: One full-duplex 1000Base-SX fiber connection to a Gigabit Ethernet LAN.
  • Attributes required: One available PCI or PCI-X card slot
  • For 9125-F2A: (#5700)
    • Minimum required: 0
    • Maximum allowed: 22 (Initial order maximum: 22)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#5701) IBM 10/100/1000 Base-TX Ethernet PCI-X Adapter

(No Longer Available as of May 29, 2009)

The IBM 10/100/1000 Base-TX Ethernet PCI-X Adapter is a Full Duplex Gigabit Ethernet adapter designed with highly integrated components. This adapter can be configured to run at 10, 100, or 1000 Mbps data rates. The adapter interfaces to the system via the PCI-X bus and connects to the network using a 4-pair CAT-5 Unshielded Twisted Pair (UTP) cable for distances of up to 100m. AIX Network Install Manager (NIM) boot capability is supported with this adapter. The adapter conforms to the IEEE 802.3ab 1000Base-T standard. The adapter also supports jumbo frames when running at the 1000 Mbps speed.

Note: For optimum performance, adapter should be placed in a 64 bit PCI-X card slot.

Limitations: The 1000 Mbps speed is not supported in Half Duplex (HDX) mode.

IOP and IOPless version

  • Attributes provided: One full-duplex 10/100/1000Base-TX UTP connection to a Gigabit Ethernet LAN.
  • Attributes required: One available PCI or PCI-X card slot
  • For 9125-F2A: (#5701)
    • Minimum required: 0
    • Maximum allowed: 22 (Initial order maximum: 22)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#5706) IBM 2-Port 10/100/1000 Base-TX Ethernet PCI-X Adapter

The IBM 2-Port 10/100/1000 Base-TX Ethernet PCI-X Adapter is a Full Duplex, dual ported, Gigabit Ethernet adapter designed with highly integrated components. This adapter can be configured to run each port at 10, 100, or 1000 Mbps data rates. The adapter interfaces to the system via a PCI or PCI-X bus and connects to a network using a 4-pair CAT-5 Unshielded Twisted Pair (UTP) cable for distances of up to 100m. AIX Network Install Manager (NIM) boot capability is supported with this adapter. The adapter conforms to the IEEE 802.3ab 1000Base-T standard. The adapter also supports jumbo frames when running at the 1000 Mbps speed.

A function called 'Large Send' or sometimes known as TCP Segmentation is also provided by this adapter. This function offloads the TCP segmentation operation from the AIX IP layer to the adapter for outgoing (transmit side) TCP segments. Another function known as "Checksum Offload" which offloads the TCP/UDP Checksum Operation or workload from the CPU to the adapter is also provided.

The IBM 2-Port 10/100/1000 Base-TX Ethernet PCI-X Adapter (#5706) should be considered where maximum port density is required per I/O card slot. For a suggested maximum number of adapters taking performance into consideration, refer to the RS/6000 and pSeries PCI Adapter Placement Reference SA38-0538. If card slots are not the limiting factor and maximum throughput is required, the single port IBM 10/100/1000 Base-TX Ethernet PCI-X Adapter (#5701) is the preferred solution.

Note: For optimum performance, the adapter should be placed in a 64 bit PCI-X card slot whenever possible.

Limitations: The 1000 Mbps speed is not supported in Half Duplex (HDX) mode.

  • Attributes provided: Two full-duplex 10/100/1000Base-TX UTP connections to Gigabit Ethernet LAN(s).
  • Attributes required: One available PCI or PCI-X card slot
  • For 9125-F2A: (#5706)
    • Minimum required: 0
    • Maximum allowed: 22 (Initial order maximum: 22)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#5707) IBM 2-Port Gigabit Ethernet-SX PCI-X Adapter

(No Longer Available as of May 29, 2009)

The IBM 2-Port Gigabit Ethernet-SX PCI-X Adapter provides two 1 Gbps (1000 Base-SX) full-duplex Ethernet LAN connections with throughput on a standard shortwave multimode optical cable that conforms to the IEEE 802.3z standard. The adapter supports distances of 260m for 62.5 micron Multi Mode Fiber (MMF) and 550m for 50.0 micron MMF. AIX Network Install Manager (NIM) boot capability is supported with this adapter.

A function called 'Large Send' or sometimes known as TCP Segmentation is also provided by this adapter. This function offloads the TCP segmentation operation from the AIX IP layer to the adapter for outgoing (transmit side) TCP segments. Another function known as "Checksum Offload" which offloads the TCP/UDP Checksum Operation or workload from the CPU to the adapter is also provided.

The IBM 2-Port Gigabit Ethernet-SX PCI-X Adapter (#5707) should be considered where maximum port density is required per I/O card slot. For a suggested maximum number of adapters taking performance into consideration, refer to the RS/6000 and pSeries PCI Adapter Placement Reference SA38-0538. If card slots are not the limiting factor and maximum throughput is required, the single port IBM Gigabit Ethernet-SX PCI-X Adapter (#5700) is the preferred solution.

Note: For optimum performance, the adapter should be placed in a 64 bit PCI-X card slot whenever possible.

Note: The 2-Port IBM Gigabit Ethernet-SX PCI-X Adapter incorporates an LC type connector on the card. This new, smaller form factor connector is being used by the industry for the next generation of fiber optic networks. If connecting into an older, existing SC type connector network, an LC-SC 62.5 Micron Fiber Converter Cable (#2459) or LC-SC 50 Micron Fiber Converter Cable (#2456) is required.

Limitation: Half Duplex (HDX) mode is not supported.

  • Attributes provided: Two full-duplex 1000Base-SX fiber connections to a Gigabit Ethernet LAN(s).
  • Attributes required: One available PCI or PCI-X card slot
  • For 9125-F2A: (#5707)
    • Minimum required: 0
    • Maximum allowed: 22 (Initial order maximum: 22)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#5710) PCI-X Dual Channel Ultra320 SCSI Blind Swap Adapter

The PCI-X Dual Channel Ultra320 SCSI Blind Swap Adapter (#5710) is a 64-bit 3.3 volt adapter and is an excellent solution for high-performance SCSI applications. The PCI-X Dual Channel Ultra320 SCSI Blind Swap Adapter provides two SCSI channels (busses), each capable of running 320 MBps (max.), up to twice the maximum data transfer rate of the previous Dual Channel Ultra3 SCSI adapter (160 MBps). Each SCSI bus can either be internal (on systems that support internal SCSI device or backplane attachments) or external. Internally attached Ultra320 devices are designed to run at a data rate of up to 320 MB per second on systems that have internal backplanes that are capable of supporting Ultra320 speeds.

In order to achieve an Ultra320 SCSI bus data rate of up to 320 MB per second and also maintain a reasonable drive distance, the adapter utilizes Low Voltage Differential (LVD) drivers and receivers. To fully utilize this 320 MB per second performance, all attaching devices should also be Ultra320 LVD devices. But, if Ultra2, Ultra3, or Ultra320 devices coexist on the same bus, each device will operate at its rated speed. For lower speed single-ended (SE) devices, the SCSI bus will switch to single-ended (SE) performance and interface to all devices on that SCSI bus at the lower SE bus data rate of the device.

Two industry standard VHDCI 68-pin connectors are mounted on the adapter's end bracket allowing attachment of various LVD and SE external subsystems. A .3 meter converter cable, VHDCI to P, Mini-68 pin to 68-pin, (#2118) can be used with older external SE devices or subsystems to allow connection to the VHDCI connector on the PCI-X Dual Channel Ultra320 SCSI Blind Swap Adapter.

The two external ports provide connectivity to an IBM 2104-DS4 Expandable Storage Plus Drawer or 2104-TS4 Expandable Storage Plus Tower at up to 320 MB/s SCSI bus data rate. The two external ports also provide connectivity to an IBM 2104-DU3 Expandable Storage Plus Drawer or 2104-TU3 Expandable Storage Plus Tower at up to 160 MB/s SCSI bus data rate and to an IBM 2104-DL1 Expandable Storage Plus Drawer or 2104-TL1 Expandable Storage Plus Tower at up to 80 MB/s SCSI bus data rate. Also the two external ports provide connectivity to numerous other SCSI external subsystems. Check the external subsystem sales/web pages for verification of connectivity support with this adapter.

The PCI-X Dual Channel Ultra320 SCSI Blind Swap Adapter (#5710) is a native boot adapter with AIX 5.1 or AIX 5.2 software in a supported pSeries or RS/6000 systems. The adapter also supports target mode.

Limitations:

  • The two external ports do not support the connection to the IBM 7131-105 IBM Multi-Storage Tower Model 105.
  • Even though the Dual Channel Ultra320 SCSI RAID Blind Swap Adapter has ports that run at ultra320 SCSI speeds (up to 320 MBytes/s), the internally attached disk drives will run at a maximum SCSI bus data rate specified by that supporting system disk backplane.
  • Disk drives internal to the pSeries system shipped prior to September 1, 2003 require a disk drive microcode update to run at Ultra320 speed. To obtain the appropriate microcode update, go to the following Web page URL:
    http://techsupport.services.ibm.com/server/mdownload/
  • Attributes provided: Attachment of internal SCSI devices (on systems that support an internal SCSI device or backplane attachment with this adapter) and external SCSI devices
  • Attributes required: One available 3.3 volt PCI or PCI-X slot
  • For 9125-F2A: (#5710)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 0)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Supported
    • CSU: No
    • Return parts MES: No

(#5708) - 10Gb FCoE PCIe Dual Port Adapter

10 Gb FCoE PCIe Dual Port Adapter (#5708) is a high-performance, 10 Gb, dual port, PCIe Converged Network Adapter (CNA) utilizing SR optics. Each port can provide NIC (Network Interface Card) traffic and Fibre Channel functions simultaneously. CCIN is 2B3B See also feature #5270 for the identical adapter except it has a low profile tail stock.

Highlights

  • PCIe 2.0 adapter with x8 Gen 1
  • Convergence Enhanced Ethernet (CEE) supported
  • SR optical transceiver with LC connection provides up to 300m cable length
  • Non-volatile error log on the adapter
  • Supported with AIX and Linux and VIOS for FC and Ethernet NIC.
  • Supported with IBM i under VIOS for FC and Ethernet NIC
  • SAN and Network boot support for AIX, Linux
  • Requires FCoCEE capable switches for full FC+Ethernet capability. Ethernet only functionality if attached to ordinary Ethernet switch.
  • Utilizes existing cabling that supports 10 Gb SR
  • Based on Qlogic Converged Network Adapter (CNA)
  • NPIV support requires VIOS for all OS environments

Configuration maximum when used for NIC traffic (not Fibre Channel usage)

  • Recommended performance Max assuming high utilization, One adapter per four active processors cores.
  • Recommended connectivity Max assuming high utilization, two adapters per one physical processor core.
  • Attributes provided: 10 Gb FCoE PCIe Dual Port Adapter
  • Attributes required: Open PCIe slot
  • For 9125-F2A: (#5708)
    • Minimum required: 0
    • Maximum allowed: 24 (Initial order maximum: 24)
    • OS level required:
      • AIX 5.3 with the 5300-11 Technology Level, or later
      • AIX 6.1 with the 6100-04 Technology Level, or later
      • SUSE Linux Enterprise Server 10 Service Pack 3 or later
      • Red Hat Enterprise Linux 5.4 or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

    Note:

  • VIOS attachment requires VIOS 2.1.2.0 or later
  • Minimum firmware level 3.5.0 or later

(#5713) 1 Gigabit iSCSI TOE PCI-X on Copper Media Adapter

The 1 Gigabit iSCSI TOE PCI-X adapter encapsulates SCSI Commands and data into TCP and transports them over the Ethernet via IP packets. The adapter operates as an iSCSI TOE (TCP/IP Offload Engine). This offload function eliminates host protocol processing and reduces CPU interrupts. Adapter uses RJ45 Gigabit Ethernet connector.

  • Attributes provided: Offload of host protocol processing
  • Attributes required: Available PCI-X Slot
  • For 9125-F2A: (#5713)
    • Minimum required: 0
    • Maximum allowed: 20 (Initial order maximum: 20)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#5714) 1 Gigabit iSCSI TOE PCI-X on Optical Media Adapter

(No longer available as of August 29, 2008)

The 1 Gigabit iSCSI TOE PCI-X adapter encapsulates SCSI Commands and data into TCP and transports them over the Ethernet via IP packets. The adapter operates as an iSCSI TOE (TCP/IP Offload Engine). This offload function eliminates host protocol processing and reduces CPU interrupts. Adapter uses Small form factor LC type fiber optic connector.

  • Attributes provided: Offload of host protocol processing
  • Attributes required: Available PCI-X Slot
  • For 9125-F2A: (#5714)
    • Minimum required: 0
    • Maximum allowed: 20 (Initial order maximum: 20)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#5716) 2 Gigabit Fibre Channel PCI-X Adapter

The 2 Gigabit Fibre Channel PCI-X Adapter is a 64-bit address/data, short form factor PCI-X adapter with an LC type external fiber connector. With the use of appropriate optical fiber cabling, this adapter provides the capability for a network of high speed local and remote located storage. The 2 Gigabit Fibre Channel PCI-X Adapter will auto-negotiate for the highest data rate (either 1 Gbps or 2 Gbps) of which the device or switch is capable. Distances of up to 500 meters running at 1 Gbps data rate and up to 300 meters running at 2 Gbps data rate are supported between the adapter and an attaching device or switch. When used with IBM supported Fibre Channel storage switches supporting long-wave optics, distances of up to 10 kilometers are capable running at either 1 Gps or 2 Gps data rates.

The 2 Gigabit Fibre Channel PCI-X Adapter can be used to attach devices either directly, or by means of Fibre Channel Switches. If attaching a device or switch with a SC type fiber onnector(s), use of an LC-SC 50 Micron Fiber Converter Cable (#2456) or a LC-SC 62.5 Micron Fiber Converter Cable (#2459) is required.

Refer to the following IBM storage subsystem Web page for additional supported server attachment information for IBM devices.

http://www.ibm.com/servers/storage/product/products_pseries.html

Consult with your IBM representative or Business Partner for additional information relative to any third party attachment.

  • Attributes provided: 1 Fibre Channel/FC-AL interface
  • Attributes required: 1 empty PCI or PCI-X slot
  • For 9125-F2A: (#5716)
    • Minimum required: 0
    • Maximum allowed: 22 (Initial order maximum: 0)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Supported
    • CSU: No
    • Return parts MES: No

(#5717) 4-Port 10/100/1000 Base-TX PCI Express Adapter

(No Longer Available as of January 1, 2014)

The 4-Port 10/100/1000 Base-TX PCI Express Adapter is full duplex, four-ported Gigabit Ethernet adapter that can be configured to run any of the ports at 1000,100 or 10 Mbps data rate. This adapter interfaces to the system via a PCIe bus and connects to a network using a 4-pair CAT-5 Unshielded Twisted Pair (UTP) cable for distance of up to 100m. Each port is independent of one another and is boot capable under AIX Network install manager (NIM). The adapter conforms to the IEEE 802.3ab 1000Base-T standard. The #5717 supports jumbo frames when running at the 1000 Mbps speed.

The 4-Port 10/100/1000 Base-TX PCI Express Adapter is a short/ low- profile capable adapter that can be configured to run any of the ports at 1000,100 or 10 Mbps data rate. This adapter interfaces to the system via a PCIe bus and connects to a network using a 4-pair CAT-5 Unshielded Twisted Pair (UTP) cable for distance of up to 100m. Each port is independent of one another and is boot capable under AIX Network install manager (NIM). The adapter conforms to the IEEE 802.3ab 1000Base-T standard. The #5717 supports jumbo frames when running at the 1000 Mbps speed.

The 4-Port 10/100/1000 Base-TX PCI Express adapter (#5717) should be considered where maximum port density is required per I/O card slot. For a suggested maximum number of adapters considering performance, see the IBM System p PCI placement guide (SA76-0090) for information about the PCIe slots on your system unit.

Limitations: The 1000 Mbps speed is not supported in Half Duplex (HDX) mode.

  • Attributes provided: Four-ported Gigabit Ethernet
  • Attributes required: One available PCIe card slot
  • For 9125-F2A: (#5717)
    • Minimum required: 0
    • Maximum allowed: 24 (Initial order maximum: 24)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#5718) 10 Gigabit Ethernet -SR PCI-X Adapter

Provides 10 Gigabit Ethernet PCI-X based server connections. Supports distances of up to 33m using 62.5 um multimode fiber or 300m using 50 um multimode fiber with 2000MHz km minimum model bandwith at 850 nm. Adapter connector type is LC.

  • Attributes provided: Provides highend bandwith for networking
  • Attributes required: Supported on PCI-X slots only
  • For 9125-F2A: (#5718)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 0)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Supported
    • CSU: No
    • Return parts MES: No

(#5719) IBM 10 Gigabit Ethernet-LR PCI-X Adapter

Offers 10 Gigabit Ethernet PCI-X based server connections over a maximum of 10 kilometers of 1310nm single-mode fiber optic cable. The adapter conforms to the IEEE 802.3ae standard. The adapter requires 9um single-mode fiber optic cables and uses a SC connector type for connecting into net-work infrastructure components like 10 Gigabit Ethernet switch/router with SC connectors.

  • Attributes provided: 10 Gigabit Ethernet connections
  • Attributes required: Available PCI-X slot
  • For 9125-F2A: (#5719)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 0)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Supported
    • CSU: No
    • Return parts MES: No

(#5721) 10 Gb Ethernet-SR PCI-X 2.0 DDR Adapter

(No Longer Available as of November 27, 2009)

The adapter supports distances of up to 33m using 62.5 um multimode fiber or 300m using 50 um multimode fiber with 2000 MHz*km minimum model bandwidth at 850 nm wavelength. The fiber cable connects to the adapter with LC type connector. The adapter conforms to the IEEE 802.3ae standard.

  • Attributes provided: Provides high-end bandwidth for networking
  • Attributes required: PCI-X slot or for improved bandwidth plug into PCI-X 2.0 DDR slot.
  • For 9125-F2A: (#5721)
    • Minimum required: 0
    • Maximum allowed: 16 (Initial order maximum: 16)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#5722) 10 Gb Ethernet-LR PCI-X 2.0 DDR Adapter

(No Longer Available as of November 28, 2008)

The adapter supports a maximum of 10 kilometers of 1310nm 9um single- mode fiber optic cable. The adapter conforms to the IEEE 802.3ae standard. The adapter requires 9um single-mode fiber optic cables and uses a SC connector to facilitate connecting into network infrastructure components like 10 Gigabit Ethernet switch/router with SC connectors.

  • Attributes provided: 10 Gigabit Ethernet connections
  • Attributes required: PCI-X slot or for improved bandwidth plug in PCI-X 2.0 DDR slot.
  • For 9125-F2A: (#5722)
    • Minimum required: 0
    • Maximum allowed: 16 (Initial order maximum: 16)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#5723) 2-Port Asynchronous EIA-232 PCI Adapter

(No Longer Available as of November 27, 2009)

Connection for 2 Asynchronous EIA-232 devices. Ports are Programmable to support EIA-232 protocols, at a line speed of 128K bps.

  • Attributes provided: 2 Asynchronous Ports
  • Attributes required: One PCI Slot
  • For 9125-F2A: (#5723)
    • Minimum required: 0
    • Maximum allowed: 18 (Initial order maximum: 18)
    • OS level required: AIX support only
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#5732) - 10 Gigabit Ethernet-CX4 PCI Express Adapter

(No Longer Available as of July 19, 2013)

The 10 Gigabit Ethernet-CX4 PCI Express Adapter is a low profile high performance adapter that transfers data over 4-lanes in each direction over copper cabling supporting a distance up to 15m.The product conforms to the IEEE, 802.3ae 10GBASE-CX4 specification for Ethernet transmission.

Highlights:

  • Implements iWARP RDMA/RDDP (Remote Direct Data Placement) which adheres to IETF (Internet Engineering Task Force) standards. (Linux Only)
  • RDMA-enabled NIC (RNIC) specifically optimized for cluster computing (Linux Only)

Full iSCSI software and hardware initiator support. (Linux Only)

  • Hardware PDU Offload (Linux Only)
  • iSCSI Header & Data Digest (CRC) generation & checking ( Linux Only)

Attributes provided:

  • PCIe-V1.1 x8
  • MSI-X, MSI and support of legacy pin interrupts
  • 10GBASE-CX short-reach copper
  • IEEE 802.3ae (10 GbE)
  • IEEE 802.1p priority and 802.1Q VLAN tagging
  • IEEE 802.3x flow control
  • Link aggregation, 802.3ad 802.3 compliance
  • IEEE 802.3ad load-balancing and failover
  • Ether II and 802.3 encapsulated frames
  • Multiple MAC addresses per interface
  • Jumbo frames up to 9.6 Kbytes
  • TCP checksum offload for IPv4 and IPv6
  • TCP segmentation Offload (TSO) for IPv4 and IPv6
  • UDP checksum offload for IPv4 and IPv6
  • Receive side scaling and packet steering
  • Line rate packet filtering and attack protection
  • IETF RDDP and RDMAC iWARP compliance (Linux Only)
  • APIs: RNIC-PI, kDAPL and Open Fabrics Enterprise Distribution(OFED) 1.4 (Linux Only)
  • Attributes provided: PCIe-V1.1 x8 Ethernet
  • Attributes required: PCIe Express Slot, Copper CX4 Cables, 4x wrap plug
  • For 9125-F2A: (#5732)
    • Minimum required: 0
    • Maximum allowed: 24 (Initial order maximum: 24)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

    Note: Maximum of 4 per processor.

    Note: Minimum Firmware EM340_063_063 or later.

(#5735) 8 Gigabit PCI Express Dual Port Fibre Channel Adapter

The 8 Gigabit PCI Express Dual Port Fibre Channel Adapter is a high-performance 8x short form adapter based on the Emulex LPe12002 PCIe Host Bus Adapter (HBA). Each port provides single initiator capability over a fibre link. The ports have LC type connectors and utilize shortwave laser optics. The adapter operates at link speeds of 2, 4, and 8 Gbps and will automatically negotiates to the highest speed possible. LEDs on each port provide information on the status and link speed of the port.

The adapter connects to a Fibre Channel switch (AIX, IBM i, Linux,VIOS). If in an IBM i environment, devices can also be directly attached.

N_Port ID Virtualization (NPIV) capability is supported through VIOS.

Cables are the responsibility of the customer. Use multimode fibre optic cables with short-wave lasers that adhere to the following specifications:

  • OM3 - multimode 50/125 micron fibre, 2000 MHz*km bandwidth
  • M2 - multimode 50/125 micron fibre, 500 MHz*km bandwidth
  • OM1 - multimode 62.5/125 micron fibre, 200 MHz*km bandwidth

Because core sizes are different, OM1 cables can only be connected to other OM1 cables. For best results, OM2 cables should not be connected to OM3 cables. However, if an OM2 cable is connected to an OM3 cable, the characteristics of the OM2 cable apply to the entire length of the cables. The following table shows the supported distances for the three different cable types at the three different link speeds.

    Cable   |  2.125 Gbps  |  4.25 Gbps  |  8.5 Gbps  |
    --------|--------------|-------------|------------|
    OM3     |.5m - 500m    |.5m - 380m   |.5m - 150m  |
    OM2     |.5m - 300m    |.5m - 150m   |.5m - 50m   |
    OM1     |.5m - 150m    |.5m - 70m    |.5m - 21m   |

#5735 feature indicates a full high adapter. #5273 feature indicates a low profile adapter which is electronically identical. CCIN is 577D. Consult with your IBM representative or Business Partner for additional information relative to any third party attachment.

  • Attributes provided: Dual Port Fibre Channel
  • Attributes required: 1 Empty PCIe slot
  • For 9125-F2A: (#5735)
    • Minimum required: 0
    • Maximum allowed: 24 (Initial order maximum: 24)
    • OS level required:
      • AIX 5L for POWER version 5.3 with the 5300-09 Technology Level.
      • AIX 6.1 with 6100-02 Technology Level.
      • SUSE Linux Enterprise Server 10 SP2 for POWER Systems or later.
      • Red Hat Enterprise LInux for POWER version 4.7 or later.
      • Red Hat Enterprise Linux for POWER version 5.2 or later.

      NPIV requires the following OS levels:

      • AIX 5.3 with the 5300-10 Technology Level, or later
      • AIX 6.1 with the 6100-03 Technology Level, or later
      • IBM i 6.1 with 6.1.1 machine code or later
      • SUSE LINUX Enterprise Server 10 SP2 for POWER Systems, or later.
      • SUSE LINUX Enterprise Server 11 for POWER Systems, or later.
      • Red Hat Enterprise Linux for POWER, Version 4.7 or later.
      • Red Hat Enterprise Linux for POWER, Version 5.2 or later.
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#5736) PCI-X DDR Dual Channel Ultra320 SCSI Adapter

(No Longer Available as of July 11, 2014)

The PCI-X DDR Dual Channel Ultra320 SCSI Adapter (#5736) is a 64-bit 3.3-volt adapter and is an excellent solution for high-performance SCSI applications. The PCI-X Dual Channel Ultra320 SCSI Adapter provides two SCSI channels (busses), each capable of running 320 MBps (max.). Each SCSI bus can either be internal (on systems that support internal SCSI device or backplane attachments) or external. Internally attached Ultra320 devices are designed to run at a data rate of up to 320 MB per second on systems that have internal backplanes that are capable of supporting Ultra320 speeds.

In order to achieve an Ultra320 SCSI bus data rate of up to 320 MB per second and maintain a reasonable drive distance, the adapter utilizes Low Voltage Differential (LVD) drivers and receivers. To utilize the 320 MB per second performance, all attaching devices should also be Ultra320 LVD devices; however, if Ultra2, Ultra3, or Ultra320 devices coexist on the same bus, each device will operate at its rated speed. For lower speed single-ended (SE) devices, the SCSI bus will switch to single-ended (SE) performance and interface to all devices on that SCSI bus at the lower SE bus data rate of the device.

Two VHDCI 68-pin connectors are mounted on the adapter's end bracket allowing attachment of various LVD and SE external subsystems. A 0.3-meter converter cable, VHDCI to P, Mini-68 pin to 68-pin, (#2118) can be used with older external SE devices or subsystems to allow connection to the VHDCI connector on the PCI-X DDR Dual Channel Ultra320 SCSI Adapter.

Two external ports provide connectivity to numerous other SCSI external subsystems. Check the external subsystem sales/Web pages for verification of connectivity support with this adapter.

The PCI-X Dual Channel Ultra320 SCSI Adapter (#5736) is a native boot adapter. The adapter also supports target mode.

Feature #5736 and #5806 are physically identical cards with the same 571A CCIN. Different features are used to help IBM configurator tool understand whether or not an IOP is being used with the adapter. #5806 indicates an IOP is present.

Limitations:

  • The two external ports do not support the connection to the IBM 7131-105 IBM Multi-Storage Tower Model 105.
  • Even though the Dual Channel Ultra320 SCSI nonRAID Adapter has ports that run at ultra320 SCSI speeds (up to 320 MBytes/s), the internally attached disk drives will run at a maximum SCSI bus data rate specified by that supporting system disk backplane.

Minimum System Firmware Required:

System firmware level required is SF235_185 or greater. Firmware level SF235_185 adjusts the PCI slots to run in Single Data Rate (SDR) mode. Enablement of Double Data Rate (DDR)slots to run at DDR mode is planned to be provided in an upcoming firmware enhancement.

For Double Data Rate (DDR), check for firmware upgrade at URL:

http://techsupport.services.ibm.com/server/mdownload2/download.html

Running the adapter on a system with firmware level lower than SF235_185 is not supported.

  • Attributes provided: Attachment of internal SCSI devices (on systems that support an internal SCSI device or backplane attachment with this adapter) and external SCSI devices
  • Attributes required: One available 3.3 volt PCI or PCI-X slot or PCI-X 2.0 DDR slot
  • For 9125-F2A: (#5736)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 8)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#5740) 4-Port 10/100/1000 Base-TX PCI-X Adapter

(No Longer Available as of November 27, 2009)

The 4-Port 10/100/1000 Base -TX PCI-X adapter is a full height PCI-X 1.0a Ethernet adapter which supports four Gigabit ports on a single adapter, delivers increased bandwidth for slot-constrained servers, and is designed to provide high connectivity and reliability using two integrated, dual-port Gigabit Ethernet controllers.

  • Four RJ-45 ports
  • 3.3 volts, 64-bit 133 MHz with 64-bit Bus Mastering on the PCI-X bus
  • IEEE 802.3ab 1000Base-T compliant
  • IEEE 802.3u 100Base-T compliant
  • IEEE 802.3 10Base-T compliant
  • 802.1q VLAN tagging
  • Interrupt Moderation
  • TCP Segmentation offload and encapsulation in hardware
  • Checksum offloading of IP, TCP, and UDP frame
  • Increased connectivity while significantly reducing CPU utilization
  • Two LED adapter status indicators per port for link activity and speed
  • NIM is supported on all 4 ports
  • RoHS compliant

Limit Full bandwidth performance may not be achieved with more than one adapter per PCI Host Bridge (PHB) or more than one CPU.

  • Attributes provided: Four 10/100/1000 RJ-45 ports
  • Attributes required: One available PCI-X card slot
  • For 9125-F2A: (#5740)
    • Minimum required: 0
    • Maximum allowed: 22 (Initial order maximum: 22)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#5748) POWER GXT145 PCI Express Graphics Accelerator

The POWER GXT145 is a versatile, low-priced 2D graphics accelerator. It can be configured to operate in either 8-bit or 24-bit color modes. This adapter supports both analog and digital monitors. The adapter requires a PCI Express slot. If attaching a device that requires a 15 pin D-Shell receptacle for a VGA connection (eg. when the graphic adapter output is routed directly to a 7316-TF3 display or indirectly through a KVM switch), order a VGA to DVI Connection Converter, feature number 4276 to accommodate the attaching device.

  • Hardware Description
    • 128-bit graphics processor
    • 8-bit indexed, 8-bit true color, or 24-bit true color
    • 32 MB SDRAM
    • x1 PCI Express interface
    • 2 DVI-I (analog/digital video) connectors
  • Features Supported
    • Up to approximately 16.7 million colors
    • Rectangular clipping
    • 1 monitor connected analog at up to 2048 x 1536 resolution
    • 1 monitor connected digital at up to 1280 x 1024 resolution
    • 2nd monitor supported on secondary connecter at up to 1600 x 1200 analog or 1280 x 1024 digital
    • 2nd monitor support in AIX is only in clone mode with an analog connection
  • APIs Supported
    • X-Windows and Motif
  • Software Requirements
    • The total number of Graphics Adapters in any one partition may not exceed four.
  • Attributes provided: 2D Graphics Adapter
  • Attributes required: 1 PCI Express Slot
  • For 9125-F2A: (#5748)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 8)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#5758) 4 GB Single-Port Fibre Channel PCI-X 2.0 DDR Adapter

(No Longer Available as of May 29, 2009)

The 4 Gigabit Single-Port Fibre Channel PCI-X 2.0 DDR Adapter is a 64-bit address/data, short form factor PCI-X adapter with an LC type external fiber connector. With the use of appropriate optical fiber cabling, this adapter provides the capability for a network of high-speed local and remote located storage. The 4 Gigabit Single-Port Fibre Channel PCI-X Adapter will auto-negotiate for the highest data rate between adapter and an attaching device at 1 Gbps, 2 Gbps or 4 Gbps of which the device or switch is capable. Distances of up to 500 meters running at 1 Gbps data rate, up to 300 meters running at 2 Gbps data rate, and 4 Gbps data rate up to 150 meters are supported between the adapter and an attaching device or switch. When used with IBM Fibre Channel storage switches supporting long-wave optics, distances of up to 10 kilometers are capable running at either 1 Gbps, 2 Gbps, or 4 Gbps data rates.

The 4 Gigabit Single-Port Fibre Channel PCI-X Adapter can be used to attach devices either directly, or by means of Fibre Channel Switches. If attaching a device or switch with a SC type fiber connector(s), use of an LC-SC 50 Micron Fiber Converter Cable (#2456) or a LC-SC 62.5 Micron Fiber Converter Cable (#2459) is required.

There are two maximum quantities for High Bandwidth adapters, one for performance, and one for connectivity. Adapter performance may be limited by bandwidth constraints in a network. To maximize High Bandwidth adapter performance in the server the performance maximum quantity should not be exceeded. In applications where the end-to-end network cannot sustain high performance and or connectivity is more important than overall bandwidth performance the performance maximum quantity can be exceeded up to the connectivity maximum quantity.

Refer to the following IBM storage subsystem Web page for additional supported server attachment information for IBM devices.

http://www.ibm.com/servers/storage/product/products_pseries.html

Consult with your IBM representative or Business Partner for additional information relative to any third party attachment.

  • Attributes provided: 1 Fibre Channel
  • Attributes required: 1 empty PCI or PCI-X 1.0 / 2.0 slot
  • For 9125-F2A: (#5758)
    • Minimum required: 0
    • Maximum allowed: 18 (Initial order maximum: 18)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#5759) 4 Gb Dual-Port Fibre Channel PCI-X 2.0 DDR Adapter

(No Longer Available as of July 11, 2014)

The 4 Gigabit Dual-Port Fibre Channel PCI-X 2.0 DDR Adapter is a 64-bit address/data, short form factor PCI-X adapter with an LC type external fiber connector. With the use of appropriate optical fiber cabling, this adapter provides the capability for a network of high-speed local and remote located storage. The adapter will auto-negotiate for the highest data rate between adapter and an attaching device at 1 Gbps, 2 Gbps, or 4 Gbps of which the device or switch is capable. Distances of up to 500 meters running at 1 Gbps data rate, up to 300 meters running at 2 Gbps data rate, and 4 Gbps data rate up to 150 meters are supported between the adapter and an attaching device or switch. When used with IBM Fibre Channel storage switches supporting long-wave optics, distances up to 10 kilometers are capable running at either 1 Gbps, 2 Gbps, or 4 Gbps data rates.

The adapter can be used to attach devices either directly, or by means of Fibre Channel Switches. If attaching a device or switch with a SC type fiber connector(s), use of an LC-SC 50 Micron Fiber Converter Cable (#2456) or a LC-SC 62.5 Micron Fiber Converter Cable (#2459) is required.

There are two maximum quantities for High Bandwidth adapters, one for performance, and one for connectivity. Adapter performance may be limited by bandwidth constraints in a network. To maximize High Bandwidth adapter performance in the server the performance maximum quantity should not be exceeded. In applications where the end-to-end network cannot sustain high performance and or connectivity is more important than overall bandwidth performance the performance maximum quantity can be exceeded up to the connectivity maximum quantity.

Refer to the following IBM storage subsystem Web page for additional supported server attachment information for IBM devices.

http://www.ibm.com/servers/storage/product/products_pseries.html

Consult with your IBM representative or Business Partner for additional information relative to any third party attachment.

Note: Please carefully consider the usage of this card. If placed in a PCI-X slot rated as SDR compatible and/or has the slot speed of 133 MHz, the AIX value of the max_xfer_size must be kept at the default setting of 0x100000 (1 megabyte) when both ports are in use. The architecture of the DMA buffer for these slots does not accommodate larger max_xfer_size settings.

  • Attributes provided: 2 Fibre Channel
  • Attributes required: 1 empty PCI or PCI-X 2.0 slot
  • For 9125-F2A: (#5759)
    • Minimum required: 0
    • Maximum allowed: 18 (Initial order maximum: 18)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#5767) 2-Port 10/100/1000 Base-TX Ethernet PCI Express Adapter

The IBM 2-Port 10/100/1000 Base-TX Ethernet PCI Express (PCIe) Adapter is a Full Duplex, dual ported, Gigabit Ethernet adapter designed with highly integrated components. This adapter can be configured to run each port at 10, 100, or 1000 Mbps data rates. The adapter interfaces to the system via a PCIe bus. It is PCIe x4 capable and conforms to the PCIe 1.0a standard. The adapter connects to a network using a 4-pair CAT-5 Unshielded Twisted Pair (UTP) cable for distances of up to 100m. AIX Network Install Manager (NIM) boot capability is supported with this adapter. The adapter conforms to the IEEE 802.3ab 1000Base-T standard. The adapter also supports jumbo frames when running at the 1000 Mbps speed.

A function called 'Large Send' or sometimes known as TCP Segmentation is also provided by this adapter. This function offloads the TCP segmentation operation from the AIX IP layer to the adapter for outgoing (transmit side) TCP segments. Another function known as "Checksum Offload" which offloads the TCP Checksum Operation or workload from the CPU to the adapter is also provided.

The IBM 2-Port 10/100/1000 Base-TX Ethernet PCIe Adapter (#5767) should be considered where maximum port density is required per I/O card slot. For a suggested maximum number of adapters taking performance into consideration, see the IBM System p PCI placement guide (SA76-0090) for information about the PCIe slots on your system unit.

Limitations: The 1000 Mbps speed is not supported in Half Duplex (HDX) mode.

  • Attributes provided: Two full-duplex 10/100/1000Base-TX UTP connections to Gigabit Ethernet LAN(s).
  • Attributes required: One available PCIe card slot
  • For 9125-F2A: (#5767)
    • Minimum required: 0
    • Maximum allowed: 24 (Initial order maximum: 24)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#5768) 2-Port Gigabit Ethernet-SX PCI Express Adapter

The IBM 2-Port Gigabit Ethernet-SX PCI Express (PCIe) Adapter provides two 1 Gbps (1000 Base-SX) full-duplex Ethernet LAN connections. The adapter interfaces to the system via a PCIe bus. It is PCIe x4 capable and conforms to the PCIe 1.0a standard. The adapter connects to a network using a 50/62.5 micron shortwave (850 nm) multimode optical cable that conforms to the IEEE 802.3z standard. The adapter supports distances of 260m for 62.5 micron Multi Mode Fiber (MMF) and 550m for 50.0 micron MMF. AIX Network Install Manager (NIM) boot capability is supported with this adapter.

A function called 'Large Send' or sometimes known as TCP Segmentation is also provided by this adapter. This function offloads the TCP segmentation operation from the AIX IP layer to the adapter for outgoing (transmit side) TCP segments. Another function known as "Checksum Offload" which offloads the TCP Checksum Operation or workload from the CPU to the adapter is also provided.

The IBM 2-Port Gigabit Ethernet-SX PCIe Adapter (#5768) should be considered where maximum port density is required per I/O card slot. For a suggested maximum number of adapters taking performance into consideration, see the IBM System p PCI placement guide (SA76-0090) for information about the PCIe slots on your system unit.

Note: The 2-Port IBM Gigabit Ethernet-SX PCIe Adapter incorporates an LC type connector on the card. This new, smaller form factor connector is being used by the industry for the next generation of fiber optic networks. If connecting into an older, existing SC type connector network, an LC-SC 62.5 Micron Fiber Converter Cable (#2459) or LC-SC 50 Micron Fiber Converter Cable (#2456) is required.

Limitation: Half Duplex (HDX) mode is not supported.

  • Attributes provided: Two full-duplex 1000Base-SX fiber connections to a Gigabit Ethernet LAN(s).
  • Attributes required: One available PCIe card slot
  • For 9125-F2A: (#5768)
    • Minimum required: 0
    • Maximum allowed: 24 (Initial order maximum: 24)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#5769) - 10 Gigabit Ethernet-SR PCI Express Adapter

The 10 Gigabit Ethernet-SR PCI Express Adapter is a full-high, high performance adapter that uses a LC Duplex type connector and is capable of transferring data a distance of 300m over MMF-850nm Fiber cable. The product conforms to the IEEE, 802.3ae 10GBASE-SR specification for Ethernet transmission.

Highlights

  • Implements iWARP RDMA/RDDP (Remote Direct Data Placement) which adheres to IETF (Internet Engineering Task Force) standards. (Linux Only)
  • RDMA-enabled NIC (RNIC) specifically optimized for cluster computing (Linux Only)
  • Full iSCSI initiator and target mode stack (Linux Only)
    • iSCSI Header & Data Digest (CRC) generation & checking (Linux Only)
    • PDU recovery (Linux Only)

Attributes

  • MSI-X, MSI and support of legacy pin interrupts
  • 10GBASE-SR short-reach optics
  • IEEE 802.3ae (10 GbE)
  • IEEE 802.1p priority and 802.1Q VLAN tagging
  • IEEE 802.3x flow control
  • Link aggregation, 802.3ad 802.3 compliance
  • IEEE 802.3ad load-balancing and failover
  • Ether II and 802.3 encapsulated frames
  • Multiple MAC addresses per interface
  • Jumbo frames up to 9.6 Kbytes
  • TCP checksum offload for IPv4 and IPv6
  • TCP segmentation Offload (TSO) for IPv4 and IPv6
  • UDP checksum offload for IPv4 and IPv6
  • Receive side scaling and packet steering
  • Line rate packet filtering and attack protection
  • IETF RDDP and RDMAC iWARP compliance (Linux Only)
  • APIs: RNIC-PI, kDAPL and OpenFabrics 1.4 (Linux Only)
  • Attributes provided: PCIe-V1.1 x8 10GBASE-SR short -reach optics adapter
  • Attributes required: PCI Express slot, Fiber Cable (Optional LC-SC 62.5 micron converter cable, 50 micron LC-SC connections), LC wrap plug-d
  • For 9125-F2A: (#5769)
    • Minimum required: 0
    • Maximum allowed: 24 (Initial order maximum: 24)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

    Note: Maximum of 4 per processor.

    Note: Minimum Firmware EM340_063_063 or later.

(#5770) System Rack with base power

(No Longer Available as of July 29, 2011)

This feature provides a 24" wide, 42U powered system rack for the 9125-F2A. The power subsystem resides in the upper 10U of the rack, and also provides the ethernet router function within the rack. The #5770 includes the base power components of two bulk power controllers and two bulk power regulators.

  • Attributes provided: System Rack with two bulk power controllers and two bulk power regulators
  • Attributes required: None
  • For 9125-F2A: (#5770)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#5772) 10 Gigabit Ethernet-LR PCI Express Adapter

The 10GbE Fiber Optic Server Adapter, is 10 Gigabit Ethernet (GbE) Fiber NIC for PCI Express (PCIe) capable systems. The adapter is a high- performance, highly integrated 10 Gigabit Ethernet LAN adapters with PCIe host interface and fiber LAN connectors on the optical modules.

Feature 5772 conforms to the 802.3ae 10GBASE-LR specification for Ethernet transmissions over 1310nm single-mode fiber optic cable for distances up to 10 kilometers.

Highlights

  • 10GBASE-LR fiber optic LAN connections
  • Eight (8) lane PCIe Host Connector
  • PCIe Low-Profile add-in card dimensions (68.9mm x 167.65mm)
  • Uses Intel 82598EB MAC
  • PCI Express bus interface v1.1 and v.2.0 (Gen 1 only)
  • PCIe Hot Plug/Active PCI
  • Controller EEPROM and FLASH ROM
  • Status LED (Link/Activity)
  • Low power PCIe Gen 1 MAC
  • MSI for multi-CPU and multi-core systems
  • Dynamic interrupt moderation for lower latency
  • Supports 10Gb, full duplex
  • Supports EtherChannel with the existing software
  • Supports IEEE 802.3ad (link aggregation control protocol)
  • IEEE 802.1Q VLANs
  • IEEE 802.3x
  • IEEE 802.1p
  • Transmission Control Protocol (TCP)/User Datagram Protocol (UDP) Checksum Offloading
  • Internet Protocol ver 4 (IPv4) Checksum Offloading
  • Transmit Checksum Offloading with TCP Segmentation Offload (TSO)/ Large Send Offload
  • Attributes provided: One 10 Gigabit Ethernet port
  • Attributes required: One x8 lane or x16 PCI Express slot
  • For 9125-F2A: (#5772)
    • Minimum required: 0
    • Maximum allowed: 24 (Initial order maximum: 24)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#5773) 4 Gigabit PCI Express Single Port Fibre Channel Adapter

(No Longer Available as of July 30, 2010)

The 4 Gigabit Single Port Fibre Channel Adapter is a 64-bit address/data, short form factor PCIe adapter with an LC type external fiber connector. With the use of appropriate optical fiber cabling, this adapter provides the capability for a network of high-speed local and remote located storage. The adapter will auto-negotiate for the highest data rate between adapter and an attaching device at 1 Gbps, 2 Gbps or 4 Gbps of which the device or switch is capable. Distances up to 500 meters running at 1 Gbps data rate, up to 300 meters running at 2 Gbps data rate, and 4 Gbps data rate up to 150 meters are supported between the adapter and an attaching device or switch. When used with IBM Fibre Channel storage switches supporting long-wave optics, distances up to 10 kilometers are capable running at either 1 Gbps, 2 Gbps, or 4 Gbps data rates.

The 4 Gigabit PCIe Single Port Fibre Channel Adapter can be used to attach devices either directly, or by means of Fibre Channel Switches. If attaching a device or switch with a SC type fiber connector(s), use of an LC-SC 50 Micron Fiber Converter Cable (#2456) or a LC-SC 62.5 Micron Fiber Converter Cable (#2459) is required.

Refer to the following IBM storage subsystem Web page for additional supported server attachment information for IBM devices.

http://www.ibm.com/servers/storage/product/products_pseries.html

Consult with your IBM representative or Business Partner for additional information relative to any third party attachment.

  • Attributes provided: 1 Fibre Channel
  • Attributes required: 1 Empty PCIe slot
  • For 9125-F2A: (#5773)
    • Minimum required: 0
    • Maximum allowed: 24 (Initial order maximum: 24)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#5774) 4 Gigabit PCI Express Dual Port Fibre Channel Adapter

The 4 Gigabit Dual Port Fibre Channel Adapter is a 64-bit address/data, short form factor PCIe adapter with an LC type external fiber connector. With the use of appropriate optical fiber cabling, this adapter provides the capability for a network of high-speed local and remote located storage. The adapter will auto-negotiate for the highest data rate between adapter and an attaching device at 1 Gbps, 2 Gbps or 4 Gbps of which the device or switch is capable. Between the adapter and an attaching device or switch, the distances supported are up to: 500 meters running at 1 Gbps data rate, 300 meters running at 2 Gbps data rate, and 150 meters running at 4 Gbps data rate. When used with IBM Fibre Channel storage switches supporting long-wave optics, distances of up to 10 kilometers are capable running at either 1 Gbps, 2 Gbps, or 4 Gbps data rates.

The 4 Gigabit PCIe Dual Port Fibre Channel Adapter can be used to attach devices either directly, or by means of Fibre Channel Switches. If attaching a device or switch with a SC type fiber connector(s), use of an LC-SC 50 Micron Fiber Converter Cable (#2456) or a LC-SC 62.5 Micron Fiber Converter Cable (#2459) is required.

Refer to the following IBM storage subsystem Web page for additional supported server attachment information for IBM devices.

http://www.ibm.com/servers/storage/product/products_pseries.html

Consult with your IBM representative or Business Partner for additional information relative to any third party attachment.

  • Attributes provided: 2 Fibre Channel
  • Attributes required: 1 Empty PCIe slot
  • For 9125-F2A: (#5774)
    • Minimum required: 0
    • Maximum allowed: 24 (Initial order maximum: 24)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#5785) - 4 Port Async EIA-232 PCIe Adapter

Connection for 4 asynchronous EIA-232 devices. Ports are programmable to support EIA-232 protocols, at a line speed of 128K bps. One connector on the rear of the adapter provides attachment for a fan-out cable (provided) which provides four EIA-232 ports. Note #5785 and # 5277 are physically and electrically identical adapters, except for the type of PCIe slot used (full-height or low-profile). Note also the 4-port #5289/5290 is functionally nearly identical to the 2-port #5289/5290 except for the number and type of connectors.

  • Attributes provided: 4-Port Asynchronous EIA-232 via 4-Port DB9 DTE Fan-Out Cable 1.2 M (4 ft.), 4 x 9-pin D-Sub (Male DB-9) and 1 x 68-pin D-Sub (HD-68)
  • Attributes required: 1 full high PCIe Slot
  • For 9125-F2A: (#5785)
    • Minimum required: 0
    • Maximum allowed: 18 (Initial order maximum: 18)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

    Note: Max of 18 #5803 / #5873.

(#5798) 12X I/O Drawer PCI-X, no repeater

(No Longer Available as of November 27, 2009)

This feature provides a 4U high I/O drawer containing twenty PCI-X slots and sixteen hot-swap disk bays. This drawer attaches to the central electronics complex via 12X cables.

  • Attributes provided:
  • 20 PCI-X Slots, 16 disk bays
  • 12X GX-Buss , no repeater
  • Attributes required: Available 12X connection ports
  • For 9125-F2A: (#5798)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#5803) - 12X I/O Drawer PCIe, SFF disk

This feature provides a 4U high I/O drawer containing twenty PCIe slots and twenty-six SAS hot-swap Small Form Factor disk bays. This drawer attaches to the central electronics complex via 12X DDR cables (#1862, #1863 or #1864). When SFF Disk are installed, they are driven by at least one SAS PCIe adapter and SAS AT cable (#3688). Using a mode switch the 26 SFF slots can be configured as one group of 26 slots (AIX/Linux) or two groups or 13 slots (AIX/IBM i/Linux) or four groups of 6 or 7 slots (AIX/Linux).

  • Attributes provided: 20 PCIe Slots, 26 SAS disk bays
  • Attributes required: Available 12X connection ports.
  • For 9125-F2A: (#5803)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#5805) - PCIe 380MB Cache Dual - x4 3Gb SAS RAID Adapter

The#5805 PCIe 380 MB Cache Dual - x4 3 Gb SAS RAID Adapter is a short, full high form factor adapter that supports the attachment of SAS disk and SAS solid state drives (SSD) using a pair of mini SAS 4x connectors. Write cache can provide an I/O performance boost even if RAID 5/6/10 is not used. From a high-level perspective, except for having a larger write cache, it is very similar to the feature 5902 PCI-X SAS adapter and provides a high-performance connection to SAS devices. Two of feature 5805 provides for mirrored write cache data and mirrored RAID parity footprints between the adapters for superior availability. Feature 5805 is installed in pairs, allowing for redundancy of the write cache. If the feature 5805 pairing is broken, then write cache is disabled. The #5805 can also be paired with a #5903 adapter.

Feature 5805 supports SAS disk drives (HDD) and SAS-bay-based SSD located in a PCIe 12X I/O Drawer or drives located in an EXP 12S Disk Drawer. AIX/Linux formatted SAS drives can be attached, and RAID 0, RAID 5, RAID 6, and RAID 10 are supported. Similarly, IBM i RAID formatted HDD and SSD can also also be attached, and RAID 5 and RAID 6 is support. AIX, IBM i and Linux also support The #5805 is electronically identical to the #5903 and both the 5903 and 5805 use CCIN number is 574E. The #5805 adapter is slightly more narrow than the #5903 due to the placement of its cache batteries.

With proper cabling and configuration, multiple wide ports are used to provide redundant paths to each dual port SAS disk or SSD.. The adapter manages SAS path redundancy and path switching should a SAS drive failure occur. The pairing of #5805 provides a high availability I/O configuration to protect against the failure of a SAS adapter. SAS X cables attach SAS disk drives in an EXP 12S Disk Drawers. SAS #3688 cables attach SFF SAS drives in an PCIe 12X I/O Drawer. The high availability I/O configuration connection is provided via the internal wiring within the PCIe 12X I/O drawer itself.

Highlights

  • Supports up to 48 SAS disks, when configured with four #5886 EXP 12S Disk Drawers
  • SAS speed = 3Gbs
  • SAS Serial SCSI Protocol (SSP)and Serial Management Protocol (SMP)
  • 380 MB of non-volatile fast write cache can increase disk subsystem performance
  • Dual controller supports mirrored write cache data and mirrored RAID parity footprints
  • Concurrent Firmware Update
  • Attributes provided: Eight physical links via two mini SAS 4x connectors.
  • Attributes required: One PCIe slot per #5805. Configuration always requires even pairs of #5805. SAS Media devices are not supported. When attaching #5886 EXP 12S at least one of the following SAS (X) cables #3661, #3662 or #3663 must be used.
  • For 9125-F2A: (#5805)
    • Minimum required: 0
    • Maximum allowed: 24 (Initial order maximum: 0)
    • OS level required: None
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes
    • Return parts MES: No

    Note: Assignment to the VIOS requires VIOS 2.1.1.0 or later

(#5873) - 12X I/O Drawer PCIe, no disk

This feature provides a 4U high I/O drawer containing twenty PCIe slots and no disk bays. This drawer attaches to the central electronics complex via 12X DDR cables (#1862, #1863 or #1864).

  • Attributes provided: 20 PCIe Slots, no disk bays
  • Attributes required: Available 12X connection ports.
  • For 9125-F2A: (#5873)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#5886) EXP 12S Expansion Drawer

(No Longer Available as of July 14, 2009)

The EXP 12S is an expansion drawer with twelve 3.5-inch form factor SAS bays. #5886 supports up to 12 hot-swap SAS Hard Disk Drives (HDD) or up to 8 hot-swap Solid State Drives (SSD). The EXP 12S includes redundant AC power supplies and two power cords. Though the drawer is one set of 12 drives which is run by one SAS controller or one pair of SAS controllers, it has two SAS attachment ports and two Service Managers for redundancy. The EXP 12S takes up a 2 EIA space in a 19-inch rack. The SAS controller can be a SAS PCI-X or PCIe adapter or pair of adapters or can be an imbedded SAS controller in a server with an imbedded SAS port such as the 8203 or 8204. Attachment to the controller is via the appropriate external SAS cables. A pair of #5886 EXP12S drawers can be attached together with SAS cables allowing the SAS controller(s) to access 24 SAS bays.

  • Attributes provided: 12 SAS bays, slot filler panels are provided for empty bays when initially shipped from IBM.
  • Attributes required:
    • Available SAS controller (PCI or imbedded server controller)
    • Power System server, POWER5 or later
    • Available 2U 19-inch rack space
  • For 9125-F2A: (#5886)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#5900) PCI-X DDR Dual -x4 SAS Adapter

The PCI-X DDR Dual Connector x4 SAS Adapter is a low-profile short form factor adapter and is an excellent solution for high-performance applications. The Adapter provides two SAS channels (busses), each supporting four ports (x4). In a wide configuration, providing redundant ports to the devices, 1 Gbs throughput is supported. In the non- redundant configuration up to 3 Gbs is supported. The adapter supports RAID level 0 (with mirroring) and 10.

Highlights

  • Wide Configuration supports addressing up to 512 SAS devices with eight ports
  • Non-Redundant configuration supports addressing 128 SAS devices per port
  • SAS speed = 3Gbs
  • SATA speed = 1.5 Gbs
  • SAS Serial SCSI Protocol (SSP) , Serial ATA Tunneling Protocol (STP) and Serial Management Protocol (SMP)
  • RAID 0 (with mirroring), 10
  • Concurrent Firmware Update
  • Removable Media Device Supported
  • Attributes provided: Eight SAS Ports through two x4 SAS channels.
  • Attributes required: One PCI-X 2.0 DDR slot
  • For 9125-F2A: (#5900)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 0)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes
    • Return parts MES: No

(#5901) - PCIe Dual-x4 SAS Adapter

The #5901 PCIe Dual-4x SAS Adapter is a low-profile short form factor adapter which supports the attachment of SAS disk, tape, and DVD using a pair of mini SAS 4x connectors. From a high level perspective, it is functionally equivalent to the #5912 PCI-X SAS adapter and provides a high-performance connection to SAS devices.

The #5901 supports external SAS tape drives such as the 36/72 GB DAT72, 80/160GB DAT160, and 800/1600GB LTO-4 found in the IBM tape units such as the 7214-1U2, TS2240, TS2340, TS3100, TS3200, and TS3310. Other removable media devices supported include IBM SAS/SATA DVD-ROM/RAM drives. SAS adapter- to-enclosure (AE) cables are used to attach these drives.

The #5901 supports SAS SFF disk drives located in a PCIe 12X I/O Drawer or SAS disk drives located in an EXP 12S Disk Drawer or drives in a Power6 system CEC (split DASD backplane). AIX/Linux formatted SAS drives are supported with RAID 0 (with mirroring) and RAID 10. IBM i formatted SAS drives are supported and data spreading and mirroring functions are provided by IBM i. RAID-5 or RAID-6 are not supported on the #5901. #5901 has zero write cache. CCIN for #5901 is 57B3.

With proper cabling and configuration, multiple wide ports are used to provide redundant paths to each dual port SAS disk . The adapter manages SAS path redundancy and path switching should a SAS drive failure occur. SAS Y cables attach SAS disk drives in an EXP 12S Disk Drawers. SAS #3688 cables attach SFF SAS drives in an PCIe 12X I/O Drawer. In the EXP 12S Drawer, a high availability I/O configuration can be created using a pair of #5901 adapters and SAS X cables to protect against the failure of a SAS adapter. In the PCIe 12X I/O Drawer, this function is provided via the internal wiring within the drawer itself.

Highlights

  • Supports up to 48 SAS disks, when configured with four #5886 EXP 12S Disk Drawers
  • Supports up to 42 disk (18 SFF disk plus up to 24 3.5-inch SAS disk) when configured with a #5802 19-inch PCIe 12X I/O Drawer and two #5886 EXP 12S Disk Drawers
  • Supports up to 50 disk (26 SFF disk plus up to 24 3.5-inch SAS disk) when configured with a #5803 24-inch PCIe 12X I/O Drawer and two #5886 EXP 12S Disk Drawers
  • SAS speed = 3Gbs
  • SATA speed = 1.5Gbs
  • SAS Serial SCSI Protocol (SSP) , Serial ATA Tunneling Protocol (STP) and Serial Management Protocol (SMP)
  • Dual controller supports mirrored RAID parity footprints
  • Concurrent firmware update
  • Attributes provided: Eight physical links via two mini SAS 4x connectors
  • Attributes required: One PCI Express slot
  • For 9125-F2A: (#5901)
    • Minimum required: 0
    • Maximum allowed: 24 (Initial order maximum: 24)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#5902) PCI-X DDR Dual - x4 3Gb SAS RAID Adapter

(No Longer Available as of November 26, 2010)

The PCI-X DDR Dual - x4 3Gb SAS RAID Adapter is a long form factor adapter and is an excellent solution for high-performance applications requiring two adapters. Two #5902 provides for mirrored write cache data and mirrored RAID parity footprints between the adapters for superior availability. With proper cabling, multiple wide ports are used to provide redundant paths to each dual port SAS disk. The adapter manages SAS path redundancy and path switching should a SAS failure occur. RAID levels 0, 5, 6, and 10 are supported. Primary use is with FC 5886 EXP 12S SAS disk expansion drawers. FC 5902 is always to be in used in a High Availability configuration using two adapters.

Highlights

  • Supports 48 SAS disks, when configured with four FC 5886 12S disk expansion drawers
  • SAS speed = 3Gbs
  • SAS Serial SCSI Protocol (SSP)and Serial Management Protocol (SMP)
  • RAID 0, 5, 6, and 10
  • 175MB of NV Fast Write Cache
  • Dual controller supports mirrored write cache data and mirrored RAID parity footprints
  • Concurrent Firmware Update
  • Attributes provided: Eight physical links via two mini SAS 4x connectors.
  • Attributes required: One PCI-X 2.0 DDR slot per #5902. Configuration always requires even pairs of #5902. SAS Media devices are not supported. When attaching #5886 EXP 12S at least one of the following SAS (X) cables #3661, #3662 or #3663 must be used.
  • For 9125-F2A: (#5902)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 8)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

    Note: Only supported in pairs

(#5903) - PCIe 380MB Cache Dual - x4 3Gb SAS RAID Adapter

(No Longer Available as of January 7, 2011)

The PCIe 380 MB Cache Dual - x4 3 Gb SAS RAID Adapter is a short, full high form factor adapter that supports the attachment of SAS disk and SAS solid state drives (SSD) using a pair of mini SAS 4x connectors. Write cache can provide an I/O performance boost even if RAID 5/6/10 is not used. From a high-level perspective, except for having a larger write cache, it is very similar to the feature 5902 PCI-X SAS adapter and provides a high-performance connection to SAS devices. Two of fea-ture 5903 provides for mirrored write cache data and mirrored RAID par-ity footprints between the adapters for superior availability. Feature 5805 is installed in pairs, allowing for redundancy of the write cache. If the feature 5805 pairing is broken, then write cache is disabled. The #5903 can also be paired with a #5805 adapter.

Feature 5805 supports SAS disk drives (HDD) and SAS-bay-based SSD located in a PCIe 12X I/O Drawer or drives located in an EXP 12S Disk Drawer. AIX/Linux formatted SAS drives can be attached, and RAID 0, RAID 5, RAID 6, and RAID 10 are supported. Similarly, IBM i RAID formatted HDD and SSD can also also be attached, and RAID 5 and RAID 6 is support. AIX, IBM i and Linux also support The #5805 is electronically identical to the #5903 and both the 5903 and 5805 use CCIN number is 574E. The #5805 adapter is slightly more narrow than the #5903 due to the placement of its cache batteries.

With proper cabling and configuration, multiple wide ports are used to provide redundant paths to each dual port SAS disk or SSD.. The adapter manages SAS path redundancy and path switching should a SAS drive failure occur. The pairing of #5903 provides a high availability I/O configuration to protect against the failure of a SAS adapter. SAS X cables attach SAS disk drives in an EXP 12S Disk Drawers. SAS #3688 cables attach SFF SAS drives in an PCIe 12X I/O Drawer. The high availability I/O configuration connection is provided via the internal wiring within the PCIe 12X I/O drawer itself.

Highlights

  • Supports up to 48 SAS disks, when configured with four #5886 EXP 12S Disk Drawers
  • SAS speed = 3Gbs
  • SAS Serial SCSI Protocol (SSP)and Serial Management Protocol (SMP)
  • 380 MB of non-volatile fast write cache can increase disk subsystem performance
  • Dual controller supports mirrored write cache data and mirrored RAID parity footprints
  • Concurrent Firmware Update
  • Attributes provided: Eight physical links via two mini SAS 4x connectors.
  • Attributes required: One PCIe slot per #5903. Configuration always requires even pairs of #5903. SAS Media devices are not supported. When attaching #5886 EXP 12S at least one of the following SAS (X) cables #3661, #3662 or #3663 must be used.
  • For 9125-F2A: (#5903)
    • Minimum required: 0
    • Maximum allowed: 24 (Initial order maximum: 24)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

    Note: Each pair support up to 50 disk (26 SFF disk plus up to 24 3.5-inch SAS disk) when configured with a #5803 24-inch PCIe 12X I/O Drawer and two #5886 EXP 12S Disk Drawers.

(#5912) PCI-X DDR Dual - x4 SAS Adapter

(No Longer Available as of July 11, 2014)

The PCI-X DDR Dual Connector x4 SAS Adapter is a low-profile short form factor adapter and is an excellent solution for high-performance applications. With proper cabling, multiple wide ports are used to provide redundant paths to each dual port SAS disk. The adapter manages SAS path redundancy and path switching should a SAS failure occur. RAID levels 0 (with mirroring) and 10 are supported. FC 5912 may also be used in a High Availability configuration using two adapters.

Highlights

  • Supports 48 SAS disks, when configured with four FC 5886 12S disk expansion drawers
  • Removable Media Device Supported
  • SAS speed = 3Gbs
  • SATA speed = 1.5Gbs
  • SAS Serial SCSI Protocol (SSP) , Serial ATA Tunneling Protocol (STP) and Serial Management Protocol (SMP)
  • RAID 0 (with mirroring) and 10
  • Dual controller supports mirrored RAID parity footprints
  • Concurrent Firmware Update
  • Attributes provided: Eight physical links via two mini SAS 4x connectors
  • Attributes required: One PCI-X 2.0 DDR slot
  • For 9125-F2A: (#5912)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 8)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#5922) Non-paired SAS RAID indicator

Feature 5922 is added for every instance of a non-paired SAS RAID adapter.

  • Attributes provided: SAS RAID adapter firmware disables cache until a second SAS RAID adapter is recognized.
  • Attributes required: Every #5922 requires a SAS RAID adapter on both this server and on another server that will pair up the SAS RAID adapter and enable the onboard caches to function.
  • For 9125-F2A: (#5922)
    • Minimum required: 0
    • Maximum allowed: no max (Initial order maximum: no max)
    • OS level required: none
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: Does not apply

(#5923) - Non-paired PCIe SAS RAID Indicator

Feature 5923 must be added for every instance of a non-paired SAS RAID adapter #5903. It identifies a specific high availability configuration supported by AIX or Linux which has one #5903 on one system and the paired #5903 located on a second system. IBM i does not support paired adapter on different servers.

  • Attributes provided: SAS RAID adapter firmware disables write cache until a second SAS RAID adapter is recognized.
  • Attributes required: Every #5923 requires a SAS RAID adapter (#5903) on both this server and on another server that will pair up the SAS RAID adapter and enable the onboard caches to function.
  • For 9125-F2A: (#5923)
    • Minimum required: 0
    • Maximum allowed: no max (Initial order maximum: no max)
    • OS level required: none
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: Does not apply

(#6069) Opt Front Door for 2.0m Rack

(No Longer Available as of July 14, 2009)

#6069 provides an attractive black full height rack door on the #0553 19 inch 2.0m Rack. The door is steel, with a perforated flat front surface. The perforation pattern extends from the bottom to the top of the door to enhance ventilation and provide some visibility into the rack.

Additional option: #6580 Optional Rack Security Kit

  • Attributes provided: Front Door
  • Attributes required: #0553 19 inch 2.0 meter Rack
  • For 9125-F2A: (#6069)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#6239) 2 Gigabit Fibre Channel PCI-X Adapter

The 2 Gigabit Fibre Channel PCI-X Adapter is a 64-bit address/data, short form factor PCI-X adapter with an LC type external fiber connector. With the use of appropriate optical fiber cabling, this adapter provides the capability for a network of high speed local and remote located storage. The 2 Gigabit Fibre Channel PCI-X Adapter will auto-negotiate for the highest data rate (either 1 Gbps or 2 Gbps) of which the device or switch is capable. Distances of up to 500 meters running at 1 Gbps data rate and up to 300 meters running at 2 Gbps data rate are supported between the adapter and an attaching device or switch. When used with IBM supported Fibre Channel storage switches supporting long-wave optics, distances of up to 10 kilometers are capable running at either 1 Gps or 2 Gps data rates.

The 2 Gigabit Fibre Channel PCI-X Adapter can be used to attach devices either directly, or by means of Fibre Channel Switches. If attaching a device or switch with a SC type fiber onnector(s), use of an LC-SC 50 Micron Fiber Converter Cable (#2456) or a LC-SC 62.5 Micron Fiber Converter Cable (#2459) is required.

Refer to the following IBM storage subsystem Web page for additional supported server attachment information for IBM devices.

http://www.ibm.com/servers/storage/product/products_pseries.html

Consult with your IBM representative or Business Partner for additional information relative to any third party attachment.

  • Attributes provided: 1 Fibre Channel/FC-AL interface
  • Attributes required: 1 empty PCI or PCI-X slot
  • For 9125-F2A: (#6239)
    • Minimum required: 0
    • Maximum allowed: 22 (Initial order maximum: 0)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Must Remove
    • CSU: No
    • Return parts MES: No

(#6247) 2.0m Rack Trim Kit

#6247 provides a decorative trim kit for the front of a #0553 19 inch 2.0m Rack.

  • Attributes provided: Decorative trim kit
  • Attributes required: #0553 19 inch 2.0 meter Rack
  • For 9125-F2A: (#6247)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#6249) 2.0m Rack Acoustic Doors

#6249 provides front and rear doors for use with the #0553 19 inch 2.0m Rack. This door kit provides additional acoustic dampening for use where a quieter environment is desired. #6249 results in a larger footprint and requires additional space.

  • Attributes provided: Acoustic Door Kit
  • Attributes required: #0553 19 inch 2.0 meter Rack
  • For 9125-F2A: (#6249)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#6319) I/O Assembly without PCI capability

(No Longer Available as of July 29, 2011)

Feature #6319 provides an I/O Assembly without PCI capability. It includes the I/O Planar, two dual 1 Gb ethernet ports, two SFF Disk bays and two 10/100 BaseT ethernet ports (for HMC connectivity). This I/O assembly would be selected for a CPU intensive node.

  • Attributes provided: I/O Assembly without PCI capability
  • Attributes required: 9125-F2A model
  • For 9125-F2A: (#6319)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#6328) Bulk Power Distribution Assembly

(No Longer Available as of July 29, 2011)

The Bulk Power Distribution assembly (#6328) provides 350VDC connector locations for cable attachment of the DC power converters within CECs and I/O Drawers.

  • Attributes provided: 350VDC Power Connectors
  • Attributes required: None
  • For 9125-F2A: (#6328)
    • Minimum required: 0
    • Maximum allowed: 4 (Initial order maximum: 4)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#6333) Bulk Power Regulator

Bulk Power Regulators provide increments of power for use by the systems components such CEC components, I/O drawers and fans.

  • Attributes provided: Regulated Power.
  • Attributes required: Bulk Power Assembly
  • For 9125-F2A: (#6333)
    • Minimum required: 0
    • Maximum allowed: 10 (Initial order maximum: 10)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#6338) Power and Ethernet cables EIA 05

This feature provides redundant power and ethernet cabling for a 9125-F2A in EIA 05, as viewed from the front of the rack.

  • Attributes provided: Redundant Power and Ethernet Cables for a 9125-F2A in EIA 05
  • Attributes required: A 9125-F2A in EIA 05
  • For 9125-F2A: (#6338)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#6339) Power and Ethernet cables EIA 07

This feature provides redundant power and ethernet cabling for a 9125-F2A in EIA 07, as viewed from the front of the rack.

  • Attributes provided: Redundant Power and Ethernet Cables for a 9125-F2A in EIA 07
  • Attributes required: A 9125-F2A in EIA 07
  • For 9125-F2A: (#6339)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#6345) 10 Gb Optical Transceivers (2x)

(No Longer Available as of July 29, 2011)

This feature provides two 10 Gigabit Optical Ethernet-SR Transceivers for enabling the 10 Gigabit ethernet ports on the 9125-F2A with the #6399 I/O Assembly.

  • Attributes provided: 10 Gb Optical Ethernet-SR Transceivers
  • Attributes required: 9125-F2A with the #6399 I/O Assembly
  • For 9125-F2A: (#6345)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#6370) Power and Ethernet cables EIA 09

This feature provides redundant power and ethernet cabling for a 9125-F2A in EIA 09, as viewed from the front of the rack.

  • Attributes provided: Redundant Power and Ethernet Cables for a 9125-F2A in EIA 09
  • Attributes required: A 9125-F2A in EIA 09
  • For 9125-F2A: (#6370)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#6371) Power and Ethernet cables EIA 11

This feature provides redundant power and ethernet cabling for a 9125-F2A in EIA 11, as viewed from the front of the rack.

  • Attributes provided: Redundant Power and Ethernet Cables for a 9125-F2A in EIA 11
  • Attributes required: A 9125-F2A in EIA 11
  • For 9125-F2A: (#6371)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#6372) Power and Ethernet cables EIA 13

This feature provides redundant power and ethernet cabling for a 9125-F2A in EIA 13, as viewed from the front of the rack.

  • Attributes provided: Redundant Power and Ethernet Cables for a 9125-F2A in EIA 13
  • Attributes required: A 9125-F2A in EIA 13
  • For 9125-F2A: (#6372)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#6373) Power and Ethernet cables EIA 15

This feature provides redundant power and ethernet cabling for a 9125-F2A in EIA 15, as viewed from the front of the rack.

  • Attributes provided: Redundant Power and Ethernet Cables for a 9125-F2A in EIA 15
  • Attributes required: A 9125-F2A in EIA 15
  • For 9125-F2A: (#6373)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#6374) Power and Ethernet cables EIA 17

This feature provides redundant power and ethernet cabling for a 9125-F2A in EIA 17, as viewed from the front of the rack.

  • Attributes provided: Redundant Power and Ethernet Cables for a 9125-F2A in EIA 17
  • Attributes required: A 9125-F2A in EIA 17
  • For 9125-F2A: (#6374)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#6375) Power and Ethernet cables EIA 19

This feature provides redundant power and ethernet cabling for a 9125-F2A in EIA 19, as viewed from the front of the rack.

  • Attributes provided: Redundant Power and Ethernet Cables for a 9125-F2A in EIA 19
  • Attributes required: A 9125-F2A in EIA 19
  • For 9125-F2A: (#6375)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#6376) Power and Ethernet cables EIA 21

This feature provides redundant power and ethernet cabling for a 9125-F2A in EIA 21, as viewed from the front of the rack.

  • Attributes provided: Redundant Power and Ethernet Cables for a 9125-F2A in EIA 21
  • Attributes required: A 9125-F2A in EIA 21
  • For 9125-F2A: (#6376)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#6377) Power and Ethernet cables EIA 23

This feature provides redundant power and ethernet cabling for a 9125-F2A in EIA 23, as viewed from the front of the rack.

  • Attributes provided: Redundant Power and Ethernet Cables for a 9125-F2A in EIA 23
  • Attributes required: A 9125-F2A in EIA 23
  • For 9125-F2A: (#6377)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#6378) Power and Ethernet cables EIA 25

This feature provides redundant power and ethernet cabling for a 9125-F2A in EIA 25, as viewed from the front of the rack.

  • Attributes provided: Redundant Power and Ethernet Cables for a 9125-F2A in EIA 25
  • Attributes required: A 9125-F2A in EIA 25
  • For 9125-F2A: (#6378)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#6379) Power and Ethernet cables EIA 27

This feature provides redundant power and ethernet cabling for a 9125-F2A in EIA 27, as viewed from the front of the rack.

  • Attributes provided: Redundant Power and Ethernet Cables for a 9125-F2A in EIA 27
  • Attributes required: A 9125-F2A in EIA 27
  • For 9125-F2A: (#6379)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#6387) Power and Ethernet cables EIA 29

This feature provides redundant power and ethernet cabling for a 9125-F2A in EIA 29, as viewed from the front of the rack.

  • Attributes provided: Redundant Power and Ethernet Cables for a 9125-F2A in EIA 29
  • Attributes required: A 9125-F2A in EIA 29
  • For 9125-F2A: (#6387)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#6388) Power and Ethernet cables EIA 31

This feature provides redundant power and ethernet cabling for a 9125-F2A in EIA 31, as viewed from the front of the rack.

  • Attributes provided: Redundant Power and Ethernet Cables for a 9125-F2A in EIA 31
  • Attributes required: A 9125-F2A in EIA 31
  • For 9125-F2A: (#6388)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#6389) I/O Risers (4 PCI-E slots)

(No Longer Available as of July 29, 2011)

The #6389 feature provides left and right I/O Riser Assemblies, with a total of up to four PCI-E slots. For every #5612 in the 575, the number of PCI-E slots is reduced by one.

  • Attributes provided: A left and right I/O riser assembly for up to four PCI-E slots.
  • Attributes required: A 9125-F2A with the #6399 I/O Assembly.
  • For 9125-F2A: (#6389)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#6392) Power cables EIA 05

This feature provides redundant power cabling for an I/O drawer in EIA 05, as viewed from the front of the rack.

  • Attributes provided: Redundant Power Cables for 4U drawer in EIA 05
  • Attributes required: 4U drawer in EIA 05
  • For 9125-F2A: (#6392)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#6393) Power cables EIA 09

This feature provides redundant power cabling for an I/O drawer or High Performance Switch (7045-SW4) in EIA 09, as viewed from the front of the rack.

  • Attributes provided: Redundant Power Cables for 4U drawer in EIA 09
  • Attributes required: 4U drawer in EIA 09
  • For 9125-F2A: (#6393)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#6394) Power cables EIA 13

This feature provides redundant power cabling for an I/O drawer in EIA 13, as viewed from the front of the rack.

  • Attributes provided: Redundant Power Cables for 4U drawer in EIA 13
  • Attributes required: 4U drawer in EIA 13
  • For 9125-F2A: (#6394)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#6395) Power cables EIA 17

This feature provides redundant power cabling for an I/O drawer in EIA 17, as viewed from the front of the rack.

  • Attributes provided: Redundant Power Cables for 4U drawer in EIA 17
  • Attributes required: 4U drawer in EIA 17
  • For 9125-F2A: (#6395)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#6396) Power cables EIA 21

This feature provides redundant power cabling for an I/O drawer in EIA 21, as viewed from the front of the rack.

  • Attributes provided: Redundant Power Cables for 4U drawer in EIA 21
  • Attributes required: 4U drawer in EIA 21
  • For 9125-F2A: (#6396)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#6397) Power cables EIA 25

This feature provides redundant power cabling for an I/O drawer in EIA 25, as viewed from the front of the rack.

  • Attributes provided: Redundant Power Cables for 4U drawer in EIA 25
  • Attributes required: 4U drawer in EIA 25
  • For 9125-F2A: (#6397)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#6398) Power cables EIA 29

This feature provides redundant power cabling for an I/O drawer in EIA 29, as viewed from the front of the rack.

  • Attributes provided: Redundant Power Cables for 4U drawer in EIA 29
  • Attributes required: 4U drawer in EIA 29
  • For 9125-F2A: (#6398)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#6399) I/O Assembly with PCI and I/O Drawer Attachment Capability

(No Longer Available as of July 29, 2011)

Feature #6399 provides an I/O Assembly with PCI capability. It includes the I/O Planar, two dual 1Gb ethernet ports, two SFF Disk bays, optional I/O Risers ( #6389) for up to four PCI-E slots, 12X Connections for I/O drawer attachment, ability to support the 10Gb Optical Transceivers (#6345) and two 10/100 BaseT ethernet ports (for HMC connectivity). This I/O assembly would be selected for an I/O intensive node.

  • Attributes provided: I/O Assembly with PCI and I/O Drawer Attachment capability
  • Attributes required: 9125-F2A model
  • For 9125-F2A: (#6399)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#6458) Power Cable -- Drawer to IBM PDU, 14-foot, 250V/10A

Standard IBM rack power cable that goes from the system or I/O drawer to the rack power distribution unit (PDU).

  • Attributes provided: Power cable
  • Attributes required: None
  • For 9125-F2A: (#6458)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#6460) Power Cord (14-foot), Drawer To OEM PDU (125V, 15A)

This power cord goes from the system or I/O drawer to the rack power distribution unit. Plug type #4 (NEMA 5-15). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. 14-foot length. The following countries/regions use the #6460 power cord to power the system and/or peripheral features requiring a power cord: United States, Antigua & Barbuda, Aruba, Bahamas, Barbados, Belize, Bermuda, Bolivia, Bonnaire, Calicos Islands, Canada, Cayman Islands, Colombia, Costa Rica, Cuba, Curacao, Dominican Republic, Ecuador, El Salvador, Guam, Guatemala, Guyana, Haiti, Honduras, Jamaica, Japan, Mexico, Micronesia, Montsderrrrat, Netherlands Antilles, Nicaragua, Panama, Peru, Philippines, St. Kitts/Nevis, St. Martin, Taiwan, Tortola (BVI), Trinidad/Tobago, Venezuela.

  • Attributes provided: Power cord
  • Attributes required: None
  • For 9125-F2A: (#6460)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#6469) Power Cord (14-foot), Drawer to OEM PDU, (250V, 15A), U. S.

This power cord goes from the system or I/O drawer to the rack power distribution unit. Plug type #5 (NEMA 6-15). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. 14-foot length. The following countries/regions use the #6469 power cord to power the system and/or peripheral features requiring a power cord: United States, Anguilla, Antigua & Barbuda, Aruba, Bahamas, Barbados, Belize, Bermuda, Bolivia, Bonnaire, Caicos Is., Canada, Cayman Islands, Colombia, Costa Rica, Cuba, Curacao, Dominican Republic, Ecuador, El Salvador, Guam, Guatamala, Haiti, Honduras, Jamaica, Japan, Micronesia, Montserrat, Netherlands Antilles, Nicaragua, Panama, Peru, Philippines, St. Marten NA, Taiwan, Tortola (BVI), Thailand, Venezuela.

  • Attributes provided: Power cord
  • Attributes required: None
  • For 9125-F2A: (#6469)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#6470) Power Cord (6-foot), To Wall (125V, 15A)

(No Longer Available as of July 14, 2009)

This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #4 (NEMA 5-15). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. 6-foot length. The following countries/regions use the #6470 power cord to power the system and/or peripheral features requiring a power cord: United States, Antigua and Barbuda, Aruba, Bahamas, Barbados, Belize, Bermuda, Bolivia, Bonnaire, Calicos Islands, Canada, Cayman Islands, Colombia, Costa Rica, Cuba, Curacao, Dominican Republic, Ecuador, El Salvador, Guam, Guatemala, Guyana, Haiti, Honduras, Jamaica, Japan, Mexico, Micronesia, Montserrat, Netherlands Antilles, Nicaragua, Panama, Peru, Philippines, St. Kitts/Nevis, St. Martin, Taiwan, Tortola (BVI), Trinidad/Tobago, Venezuela.

  • Attributes provided: Power cord
  • Attributes required: None
  • For 9125-F2A: (#6470)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#6471) Power Cord (9-foot), To Wall/OEM PDU, (125V, 15A)

(No Longer Available as of July 14, 2009)

This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #70 (iNMETRO NBR 6147, NEMA 5-15). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. The following countries/regions use the #6471 power cord to power the system and/or peripheral features requiring a power cord: Brazil

  • Attributes provided: Power cord
  • Attributes required: None
  • For 9125-F2A: (#6471)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#6472) Power Cord (9-foot), To Wall/OEM PDU, (250V, 16A)

(No Longer Available as of July 14, 2009)

This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #18 (CEE 7 VII). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. The following countries/regions use the #6472 power cord to power the system and/or peripheral features requiring a power cord: Afghanistan, Albania, Algeria, Andorra, Angola, Armenia, Austria, Belarus, Belgium, Benin, Bosnia/Herzegovina, Bulgaria, Burkina Faso, Burundi, Cambodia, Cameroon, Cape Verde, Central African Republic, Chad, Comoros, Conogo, Croatia, Czech Republic, Dahomey, Djibuouti, Egypt, Equatorial Guinea, Eritrea, Estonia, Etrhiopia, Finland, France, French Polynesia, French Guyana, Gabon, Georgia, Germany, Greece, Guadeloupe, Guinea, Guinea-Bissau, Hungary, Iceland, Indonesia, Iran, Ivory Coast, Kazakhstan, Krygystan, Laos, Latvia, Lebanon, Lintuania, Luxembourg, Macau, Macedonia, Mali, Martinigue, Mauritania, Mauritus, Mayotte, Moldova, Monaco, Mongolia, Morocco, Mozambique, Netherlands, New Caledonia, Niger, North Korea (C19 only), Norway, Poland, Portugal, Principe, Reunion, Romania, Russia, Rwanda, St. Thomas, Saudi Arabia, Senegal, Serbia, Slovenia, Somalia, South Korea (C19 only), Spain, Surinam, Sweden, Syria, Tahiti, Tajikistan, Togo, Tunesia, Turkey, Turkmenistan, Ukraine, Upper Volta, Uzbekistan, Vanuatu, Vietnam, Wallis & Futuna, Zaire, Zimbabwe.

  • Attributes provided: Power cord
  • Attributes required: None
  • For 9125-F2A: (#6472)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#6473) Power Cord (9-foot), To Wall/OEM PDU, (250V, 10A)

(No Longer Available as of July 14, 2009)

This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #19 (CEE). Refer to Corporate Bulletin C-B- 2-4700-009 for a description of plug types. The following countries/regions use the #6473 power cord to power the system and/or peripheral features requiring a power cord: Denmark

  • Attributes provided: Power cord
  • Attributes required: None
  • For 9125-F2A: (#6473)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#6474) Power Cord (9-foot), To Wall/OEM PDU, (250V, 13A)

(No Longer Available as of July 14, 2009)

This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #23 (BS 1364A). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. The following countries/regions use the #6474 power cord to power the system and/or peripheral features requiring a power cord: Abu Dhabi, Bahrain, Botswana, Brunei, Channel Islands, Cyprus, Dominica, Gambia, Grenada, Grenadines, Guyana, Hong Kong, Iraq, Ireland, Jordan, Kenya, Kuwait, Liberia, Malawi, Malaysia, Malta, Myanmar, Nkigeria, Oman, Qatar, Sierra Leone, Singapore, St. Kitts, St. Lucia, Seychelles, Sudan, Tanzania, Trinidad & Tobago, United Arab Emirates, United Kingdom, Yemen, Zambia

  • Attributes provided: Power cord
  • Attributes required: None
  • For 9125-F2A: (#6474)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#6475) Power Cord (9-foot), To Wall/OEM PDU, (250V, 16A)

(No Longer Available as of July 14, 2009)

This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #32 (SII 32-1971). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. The following countries/regions use the #6475 power cord to power the system and/or peripheral features requiring a power cord: Israel

  • Attributes provided: Power cord
  • Attributes required: None
  • For 9125-F2A: (#6475)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#6476) Power Cord (9-foot), To Wall/OEM PDU, (250V, 10A)

(No Longer Available as of July 14, 2009)

This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #24 (SEV 24507). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. The following countries/regions use the #6476 power cord to power the system and/or peripheral features requiring a power cord: Lichtenstein Switzerland

  • Attributes provided: Power cord
  • Attributes required: None
  • For 9125-F2A: (#6476)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#6477) Power Cord (9-foot), To Wall/OEM PDU, (250V, 16A)

(No Longer Available as of July 14, 2009)

This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #22 (SABS 164). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. The following countries/regions use the #6477 power cord to power the system and/or peripheral features requiring a power cord: Bangladesh LeSotho Maceo Maldives Nambia Pakistan Samoa South Africa Sri Lanka Swaziland Uganda

  • Attributes provided: Power cord
  • Attributes required: None
  • For 9125-F2A: (#6477)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#6478) Power Cord (9-foot), To Wall/OEM PDU, (250V, 16A)

(No Longer Available as of July 14, 2009)

This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #25 (CEI 23-16). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. The following countries/regions use the #6478 power cord to power the system and/or peripheral features requiring a power cord: Chile Italy Libya

  • Attributes provided: Power cord
  • Attributes required: None
  • For 9125-F2A: (#6478)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#6487) Power Cord (6-foot),To Wall, (250V, 15A), United States

(No Longer Available as of July 14, 2009)

This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #5 (NEMA 6-15). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. 6-foot length. The following countries/regions use the #6487 power cord to power the system and/or peripheral features requiring a power cord: United States, Anguilla, Antigua & Barbuda, Aruba, Bahamas, Barbados, Belize, Bermuda, Bolivia, Bonnaire, Caicos Is., Canada, Cayman Islands, Colombia, Costa Rica, Cuba, Curacao, Dominican Republic, Ecuador, El Salvador, Guam, Guatamala, Haiti, Honduras, Jamaica, Japan, Micronesia, Montserrat, Netherlands Antilles, Nicaragua, Panama, Peru, Philippines, St. Marten NA, Taiwan, Tortola (BVI), Thailand, Venezuela.

  • Attributes provided: Power cord
  • Attributes required: None
  • For 9125-F2A: (#6487)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#6488) Power Cord (9-foot), To Wall/OEM PDU, (125V, 15A or 250V, 10A )

(No Longer Available as of July 14, 2009)

This power cord goes from the system and/or peripheral features to a wall-type outlet. 125V, 15A or 250V, 10A, Plug Type #2. Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. The following countries/regions use the #6488 power cord to power the system and/or peripheral features requiring a power cord: Argentina, Paraguay and Uruguay

  • Attributes provided: Power cord
  • Attributes required: None
  • For 9125-F2A: (#6488)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#6492) 14-Ft 1PH/48-60A Pwr Cord

(No Longer Available as of July 14, 2009)

#6492 is a 14-FT/4.3m 200-240V/48A power cord with a Type 46 plug which distributes power from a power source to a Power Distribution Unit.

  • Attributes provided: power cord
  • Attributes required: None
  • For 9125-F2A: (#6492)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#6493) Power Cord (9-foot), To Wall/OEM PDU, (250V, 10A)

(No Longer Available as of July 14, 2009)

This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #62 (GB 1053). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. The following countries/regions use the #6493 power cord to power the system and/or peripheral features requiring a power cord: People's Republic of China

  • Attributes provided: Power cord
  • Attributes required: None
  • For 9125-F2A: (#6493)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#6494) Power Cord (9-foot), To Wall/OEM PDU, (250V, 10A)

(No Longer Available as of July 14, 2009)

This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #69 (IS 6538). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. The following countries/regions use the #6494 power cord to power the system and/or peripheral features requiring a power cord: India

  • Attributes provided: Power cord
  • Attributes required: None
  • For 9125-F2A: (#6494)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#6495) Power Cord (9-foot), To Wall/OEM PDU, (250V, 10A)

(No Longer Available as of July 14, 2009)

(No longer available as of August 29, 2008)

This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #73. Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. The following countries/regions use the #6495 power cord to power the system and/or peripheral features requiring a power cord: Brazil

  • Attributes provided: Power cord
  • Attributes required: None
  • For 9125-F2A: (#6495)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#6496) Power Cord (9-foot), To Wall/OEM PDU, (250V, 10A)

(No Longer Available as of July 14, 2009)

This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #66 (KETI). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. The following countries/regions use the #6496 power cord to power the system and/or peripheral features requiring a power cord: North Korea South Korea

  • Attributes provided: Power cord
  • Attributes required: None
  • For 9125-F2A: (#6496)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#6580) Optional Rack Security Kit

(No Longer Available as of July 14, 2009)

This feature provides hardware that can be added to a rack to prevent unauthorized access. It includes keyed front and rear locks for the #0553 rack doors. It also includes two sliding bars that mount inside the left and right rack side panels. The sliding bars are accessible when the rack rear door is open. They can be moved to a position that disables the external latches on the rack side panels, and prevents removal of the side panels.

  • Attributes provided: Locking hardware for rack doors and sidepanels
  • Attributes required: #0553 2.0 meter Rack
  • For 9125-F2A: (#6580)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#6651) Power Cord (9-foot), To Wall/OEM PDU, (125V, 15A)

(No Longer Available as of July 14, 2009)

This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #75 (KETI). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. The following countries/regions use the #6651 power cord to power the system and/or peripheral features requiring a power cord: Taiwan

  • Attributes provided: Power cord
  • Attributes required: None
  • For 9125-F2A: (#6651)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#6654) 14-Ft 1PH/24-30A Pwr Cord

(No Longer Available as of July 14, 2009)

#6654 is a 14-FT/4.3m 200-240V/24A locking power cord with a Type 12 plug which distributes power from a power source to a Power Distribution Unit.

  • Attributes provided: power cord
  • Attributes required: None
  • For 9125-F2A: (#6654)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#6655) 14-Ft 1PH/24-30A WR Pwr Cord

(No Longer Available as of July 14, 2009)

#6655 is a 14-FT/4.3m 200-240V/24A water-resistant power cord with a Type 40 plug which distributes power from a power source to a Power Distribution Unit.

  • Attributes provided: power cord
  • Attributes required: None
  • For 9125-F2A: (#6655)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#6659) Power Cord (9-foot), To Wall/OEM PDU, (250V, 15A)

(No Longer Available as of July 14, 2009)

This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #76 (KETI). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. The following countries/regions use the #6659 power cord to power the system and/or peripheral features requiring a power cord: Taiwan

  • Attributes provided: Power cord
  • Attributes required: None
  • For 9125-F2A: (#6659)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#6660) Power Cord (14-foot), Drawer To OEM PDU (125V, 15A)

(No Longer Available as of July 14, 2009)

This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #59 (NEMA 5-15). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. 14-foot length. This power cord meets the DENAN marking requirement in Japan.

  • Attributes provided: Power Cord
  • Attributes required: None
  • For 9125-F2A: (#6660)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#6669) Power Cord (14-foot), Drawer to OEM PDU, (250V, 15A)

(No Longer Available as of July 14, 2009)

This power cord goes from the system or I/O drawer to the rack power distribution unit. Plug type #57 (NEMA 6-15). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. 14-foot length. This power cord meets the DENAN marking requirement in Japan.

  • Attributes provided: Power Cord
  • Attributes required: None
  • For 9125-F2A: (#6669)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#6670) Power Cord (6-foot), To Wall (125V, 15A),

(No Longer Available as of July 14, 2009)

(No longer available as of August 29, 2008)

This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #59 (NEMA 5-15). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. 6-foot length. This power cord meets the DENAN marking requirement in Japan.

  • Attributes provided: Power cord
  • Attributes required: None
  • For 9125-F2A: (#6670)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#6671) Power Cord (9-foot), Drawer to IBM PDU, 250V/10A

(No Longer Available as of July 14, 2009)

Standard IBM rack power cable that goes from the system or I/O drawer to the rack power distribution unit (PDU). 9-foot length.

  • Attributes provided: Power Cord
  • Attributes required: None
  • For 9125-F2A: (#6671)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#6672) Power Cord (5-foot), Drawer to IBM PDU, 250V/10A

(No Longer Available as of July 14, 2009)

Standard rack power cable that goes from the system or I/O drawer to the rack power distribution unit (PDU). 5-foot length.

  • Attributes provided: Power Cord
  • Attributes required: None
  • For 9125-F2A: (#6672)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#6680) Power Cord (9-foot), To Wall/OEM PDU, (250V, 10A)

(No Longer Available as of July 14, 2009)

This insulated power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #6 (AS 3112-1964 NZS 198). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. The following countries/regions use the #6680 power cord to power the system and/or peripheral features requiring a power cord: Australia, Fiji Islands, Kiribati, Nauru, New Zealand, Papua New Guinea, W. Samoa.

  • Attributes provided: Power cord
  • Attributes required: None
  • For 9125-F2A: (#6680)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#6687) Power Cord (6-foot), To Wall, (250V, 15A)

(No longer available as of August 29, 2008)

This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #57 (NEMA 6-15). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. 6-foot length. This power cord meets the DENAN marking requirement in Japan.

  • Attributes provided: Power cord
  • Attributes required: None
  • For 9125-F2A: (#6687)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: No Max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#6872) Water cooling option

(No Longer Available as of July 29, 2011)

This feature provides two modular water cooling units, the rack level supply and return manifolds, the internal connection hoses to the modular water units, and the internal power cables for the modular water units. The modular water units also supply cool water to the integrated rear door heat exchanger.

  • Attributes provided: Water cooling components to support the water cooled 9125-F2A
  • Attributes required: For use with the #5770 rack.
  • For 9125-F2A: (#6872)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#6873) Coolant fill and purge tool

(No Longer Available as of July 29, 2011)

This feature provides the coolant fill and purge tool used with the #6872 Water Cooling Option. This feature can be removed from additional rack orders to prevent multiple quantities of the Coolant Fill/Purge Tool from being shipped. Failure to have at least one Coolant Fill/Purge Tool in a location that has water cooled nodes may result in delayed or prolonged maintenance times.

  • Attributes provided: Coolant fill and purge tool
  • Attributes required: For use with #6872 Water Cooling Option
  • For 9125-F2A: (#6873)
    • Minimum required: 0
    • Maximum allowed: 99 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#6874) Slim doors with integrated rear heat exchanger

(No Longer Available as of July 29, 2011)

This feature provides a slim line front door and a rear door with an integrated heat exchanger for use with the #5770 rack that have the water cooling option #6872.

  • Attributes provided: Door kit with slim line front door and a rear door with integrated heat exchanger.
  • Attributes required: #5770 rack with water cooling option #6872.
  • For 9125-F2A: (#6874)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#6875) Acoustic doors with integrated rear heat exchanger

(No Longer Available as of July 29, 2011)

This feature provides an acoustic front door and a rear door with an integrated heat exchanger for use with the #5770 rack that have the water cooling option #6872.

  • Attributes provided: Door kit with acoustic front door and a rear door with integrated heat exchanger.
  • Attributes required: #5770 rack with water cooling option #6872.
  • For 9125-F2A: (#6875)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#6876) Coolant Supply/Return Hoses, 6'

Feature #6876 provides a set of coolant supply and return hoses (2 supply, 2 return) in a 6 foot length to connect the Power 575 (9125-F2A) #6872 Water Cooling Option's modular water units to the customer cooling manifolds. When ordered with the 9125-F2A, the #6876 is delivered along with the system delivery. In the event that the installation site needs to be prepared prior to the 9125-F2A system delivery, #6876 should be ordered on the 9125-F2B.

  • Attributes provided: Two supply and two return hoses in 6 foot lengths
  • Attributes required: None
  • For 9125-F2A: (#6876)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: No

(#6877) Coolant Supply/Return Hoses, 14'

Feature #6877 provides a set of coolant supply and return hoses (2 supply, 2 return) in a 14 foot length to connect the Power 575 (9125-F2A) #6872 Water Cooling Option's modular water units to the customer cooling manifolds. When ordered with the 9125-F2A, the #6877 is delivered along with the system delivery. In the event that the installation site needs to be prepared prior to the 9125-F2A system delivery, #6877 should be ordered on the 9125-F2B.

  • Attributes provided: Two supply and two return hoses in 14 foot lengths
  • Attributes required: None
  • For 9125-F2A: (#6877)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: No

(#7109) Intelligent PDU+, 1 EIA Unit, Universal UTG0247 Connector

(No Longer Available as of July 14, 2009)

This feature is for an intelligent AC power distribution unit (PDU+) that will allow the user to monitor the amount of power being used by the devices that are plugged in to this PDU+. This AC power distribution unit provides twelve C13 power outlets. It receives power through a UTG0247 connector. It can be used for many different countries and applications by varying the PDU to Wall Power Cord, which must be ordered separately. Each PDU requires one PDU to Wall Power Cord. Supported power cords include the following features: #6489, #6491, #6492, #6653, #6654, #6655, #6656, #6657, and #6658.

  • Attributes provided: Twelve C13 outlets with Power Monitoring Capability
  • Attributes required: PDU to Wall power cord
  • For 9125-F2A: (#7109)
    • Minimum required: 0
    • Maximum allowed: 4 (Initial order maximum: 4)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#7188) Power Distribution Unit

(No Longer Available as of July 14, 2009)

An AC Power Distribution Unit (PDU) which mounts in a 19" rack and provides twelve C13 power outlets. The #7188 has six 16A circuit breakers, with two power outlets per circuit breaker. System units and/or expansion units must use a power cord with a C14 plug to connect to the #7188.

One of the following line cords must be used to distribute power from a wall outlet to the #7188;

  • #6489 - 14-Ft 3PH/24A Power Cord
  • #6491 - 14-Ft 1PH/63A Pwr Cord
  • #6492 - 14-Ft 1PH/48-60A Pwr Cord
  • #6653 - 14-Ft 3PH/16A Power Cord
  • #6654 - 14-Ft 1PH/24-30A Pwr Cord
  • #6655 - 14-Ft 1PH/24-30A WR Pwr Cord
  • #6656 - 14-Ft 1PH/32A Power Cord
  • #6657 - 14-Ft 1PH/24A Power Cord
  • #6658 - 14-Ft 1PH/24A Pwr Cd-Korea
  • Attributes provided: Power Distribution Unit withTwelve C13 power outlets.
  • Attributes required: 19" Rack
  • For 9125-F2A: (#7188)
    • Minimum required: 0
    • Maximum allowed: 4 (Initial order maximum: 4)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#7298) 0/32 Core 4.7GHz POWER6 CPU

(No Longer Available as of July 30, 2010)

This feature provides a 0/32 core 4.7GHz POWER6 water cooled Processor, 512 MB L3 Cache, and System Planar. The System Planar incorporates 64 memory DIMM slots.

  • Attributes provided: 0/32 Core 4.7GHz POWER6 water cooled Processor, 512 MB L3 Cache, System Planar.
  • Attributes required: 9125-F2A Machine Type Model
  • For 9125-F2A: (#7298)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: No
    • Return parts MES: Does not apply

(#7299) One CPU activation for #7298

(No Longer Available as of September 26, 2014)

This feature provides one processor activation for the FC 7298 processor.

  • Attributes provided: One processor activation for FC 7298
  • Attributes required: FC 7298 with unactivated processor
  • For 9125-F2A: (#7299)
    • Minimum required: 0
    • Maximum allowed: 32 (Initial order maximum: 32)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

(#7801) Ethernet Cable, 6M, Hardware Management Console to System Unit

This feature provides a six meter long Ethernet cable for attachment of a Hardware Management Console to the system unit.

  • Attributes provided: 6M Ethernet Cable
  • Attributes required: Ethernet port on Hardware Management Console
  • For 9125-F2A: (#7801)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#7802) Ethernet Cable, 15M, Hardware Management Console to System Unit

This feature provides a fifteen meter long Ethernet cable for attachment of a Hardware Management Console to the system unit.

  • Attributes provided: 15M Ethernet Cable
  • Attributes required: Ethernet port on Hardware Management Console
  • For 9125-F2A: (#7802)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: No max)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#7937) Bolt-Down Kit, Low-Raised Floor

This feature provides rack ruggedizing and bolt down hardware for securing rack to a concrete floor beneath a 9" to 13" (228mm to 330mm) raised floor. Installation of this feature will help to secure and protect the rack and it's contents from damage when exposed to vibrations and shocks such as those in a seismic event.

  • Attributes provided: Rack bolt down kit
  • Attributes required: System or expansion rack
  • For 9125-F2A: (#7937)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#7938) Bolt-Down Kit, High-Raised Floor

This feature provides rack ruggedizing and bolt down hardware for securing rack to a concrete floor beneath a 12" to 22" (305mm to 559mm) raised floor. Installation of this feature will help to secure and protect the rack and it's contents from damage when exposed to vibrations and shocks such as those in a seismic event.

  • Attributes provided: Rack bolt down kit
  • Attributes required: System or expansion rack
  • For 9125-F2A: (#7938)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#7949) PowerVM - Standard

This feature allows the customer to create partitions that are in units of less than 1 CPU (sub-CPU LPARs) and allows the same system I/O to be virtually allocated to these partitions. The processors on the system can be partitioned into as many as 10 LPARs per processor. An encrypted key is supplied to the customer and installed on the system, authorizing the partitioning at the sub-processor level. Included with Feature 7949 is the IBM Virtual I/O Server (5765-G34) to provide additional virtualization function.

  • Attributes provided: System virtualization
  • Attributes required: None
  • For 9125-F2A: (#7949)
    • Minimum required: 0
    • Maximum allowed: 32 (Initial order maximum: 32)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

    Note: If #7949 is ordered on a Model F2A, the quantity must be equal to the number of activated processors. Once the Virtualization feature is installed in a system, it cannot be removed.

(#7960) Compact Handling Option

This feature allows the System or expansion rack to pass through doors at the customer location which are less than the 2.02M (79.5") normally required. With this feature the top section of the rack (including the power subsystem) is removed at the factory and shipped separately for installation at the customer location.

  • Attributes provided: Reduced height for shipping.
  • Attributes required: None
  • For 9125-F2A: (#7960)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#8024) PowerVM - Enterprise

This feature allows the customer to create partitions that are in units of less than 1 CPU (sub-CPU LPARs) and allows the same system I/O to be virtually allocated to these partitions. The processors on the system can be partitioned into as many as 10 LPARs per processor. An encrypted key is supplied to the customer and installed on the system, authorizing the partitioning at the sub-processor level. Included with Feature 8024 is the IBM Virtual I/O Server (5765-G34) and Live Partition Mobility, which allows for the movement of a logical partition from one POWER6 processor-based server to another with no application downtime. to provide additional virtualization function.

  • Attributes provided: System virtualization with Live Partition Mobility
  • Attributes required: None
  • For 9125-F2A: (#8024)
    • Minimum required: 0
    • Maximum allowed: 32 (Initial order maximum: 32)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

    Note: If #8024 is ordered on a Model F2A, the quantity must be equal to the number of activated processors. Once the Virtualization feature is installed in a system, it cannot be removed. Feature 8024 requires system firmware level ES330_028 or later.

(#8453) Base Customer Spec Plcmnt

(No Longer Available as of July 30, 2010)

  1. Requests that IBM deliver the system to the customer according to the slot in drawer hardware placement defined by the account team.

  2. Eliminates the need to have these parts relocated in the customers environment as may happen if the order is placed without this feature code.

  3. Client placement specifications are collected using the System Planning Tool (SPT) and processed through the marketing configurator. (Use of the SPT is not required).

  4. Requires account team to submit the output of the marketing configurator into IBM manufacturing via the CSP Web site:
    http://www.ibm.com/eserver/power/csp

    (US Business Partners and Distributors can bypass this step.)

  5. Requires account team to assure that the marketing configurator output submitted reflects the actual order placed.
  • Attributes provided: I/O component placement
  • Attributes required: Marketing Configurator output submitted to the CSP Web site (US Business Partners and Distributors can bypass this step.)
  • For 9125-F2A: (#8453)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: No
    • Return parts MES: Does not apply

(#8694) Line Cord, 6AWG, 14ft, No Plug

(No Longer Available as of February 9, 2010)

Note: Not available in U.S. or Canada.

This feature provides a 14 ft 6AWG line cord with no plug. It may be utilized for 380-415V circuits at loadings up to 43A.

  • Attributes provided: 14 ft Line Cord with No Plug
  • Attributes required: None
  • For 9125-F2A: (#8694)
    • Minimum required: 0
    • Maximum allowed: 4 (Initial order maximum: 4)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#8695) Line Cord, 4AWG, 14ft, No Plug

This feature provides a 14 ft 4AWG line cord with no plug. It may be utilized for 200-240V circuits at loadings up to 80A.

  • Attributes provided: Power Connection to service.
  • Attributes required: None
  • For 9125-F2A: (#8695)
    • Minimum required: 0
    • Maximum allowed: 4 (Initial order maximum: 4)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#8696) Line Cord, 4AWG, 14ft, 100A Plug

This feature provides a 14 ft 4AWG line cord with a 100 amp plug. It may be utilized for 200-240V circuits at loadings up to 80A.

  • Attributes provided: Power Connection to service.
  • Attributes required: None
  • For 9125-F2A: (#8696)
    • Minimum required: 0
    • Maximum allowed: 4 (Initial order maximum: 4)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#8699) Line Cord, 6AWG, 14ft, 60A Plug

This feature provides a 14 ft 6AWG line cord with a 60 amp plug. It may be utilized for 480V circuits at loadings up to 34A.

  • Attributes provided: Power Connection to service.
  • Attributes required: None
  • For 9125-F2A: (#8699)
    • Minimum required: 0
    • Maximum allowed: 4 (Initial order maximum: 4)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: No
    • Return parts MES: No

(#9300) Language Group Specify - US English

(No Longer Available as of July 30, 2010)

English language group for nomenclature and standard publications.

  • Attributes provided: None
  • Attributes required: None
  • For 9125-F2A: (#9300)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply

(#9440) New AIX License Core Counter

(No Longer Available as of July 30, 2010)

This feature is used to count the number of cores licensed to run AIX.

  • Attributes provided: None
  • Attributes required: None
  • For 9125-F2A: (#9440)
    • Minimum required: 0
    • Maximum allowed: 32 (Initial order maximum: 32)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply

(#9442) New Red Hat License Core Counter

(No Longer Available as of July 30, 2010)

This feature is used to count the number of cores licensed to run Red Hat Linux.

  • Attributes provided: None
  • Attributes required: None
  • For 9125-F2A: (#9442)
    • Minimum required: 0
    • Maximum allowed: 32 (Initial order maximum: 32)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply

(#9443) New SUSE License Core Counter

(No Longer Available as of July 30, 2010)

This feature is used to count the number of cores licensed to run SUSE Linux.

  • Attributes provided: None
  • Attributes required: None
  • For 9125-F2A: (#9443)
    • Minimum required: 0
    • Maximum allowed: 32 (Initial order maximum: 32)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply

(#9444) Other AIX License Core Counter

(No Longer Available as of July 30, 2010)

This feature is used to count the number of existing AIX licenses transferred from another server.

  • Attributes provided: None
  • Attributes required: None
  • For 9125-F2A: (#9444)
    • Minimum required: 0
    • Maximum allowed: 32 (Initial order maximum: 32)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply

(#9445) Other Linux License Core Counter

(No Longer Available as of July 30, 2010)

This feature is used to count the number of existing Linux licenses transferred from another server.

  • Attributes provided: None
  • Attributes required: None
  • For 9125-F2A: (#9445)
    • Minimum required: 0
    • Maximum allowed: 32 (Initial order maximum: 32)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply

(#9446) 3rd Party Linux Core Counter

(No Longer Available as of July 30, 2010)

This feature is used to count the number of cores licensed to run 3rd party Linux.

  • Attributes provided: None
  • Attributes required: None
  • For 9125-F2A: (#9446)
    • Minimum required: 0
    • Maximum allowed: 32 (Initial order maximum: 32)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply

(#9447) VIOS Core Counter

(No Longer Available as of July 30, 2010)

This feature is used to count the number of cores licensed to run VIOS (Virtual I/O Server).

  • Attributes provided: None
  • Attributes required: None
  • For 9125-F2A: (#9447)
    • Minimum required: 0
    • Maximum allowed: 32 (Initial order maximum: 32)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply

(#9700) Language Group Specify - Dutch

(No Longer Available as of July 30, 2010)

Dutch language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 9125-F2A: (#9700)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply

(#9703) Language Group Specify - French

(No Longer Available as of July 30, 2010)

French language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 9125-F2A: (#9703)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply

(#9704) Language Group Specify - German

(No Longer Available as of July 30, 2010)

German language group for Nomenclature and Standard Publications.

  • Attributes provided: Language specify
  • Attributes required: None
  • For 9125-F2A: (#9704)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply

(#9705) Language Group Specify - Polish

(No Longer Available as of July 30, 2010)

Polish language group for Nomenclature and Standard Publications.

  • Attributes provided: Language specify
  • Attributes required: none
  • For 9125-F2A: (#9705)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply

(#9706) Language Group Specify - Norwegian

(No Longer Available as of July 30, 2010)

Norwegian language group for Nomenclature and Standard Publications.

  • Attributes provided: Language specify
  • Attributes required: None
  • For 9125-F2A: (#9706)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply

(#9707) Language Group Specify - Portuguese

(No Longer Available as of July 30, 2010)

Portuguese language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 9125-F2A: (#9707)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply

(#9708) Language Group Specify - Spanish

(No Longer Available as of July 30, 2010)

Spanish language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 9125-F2A: (#9708)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply

(#9711) Language Group Specify - Italian

(No Longer Available as of July 30, 2010)

Italian language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 9125-F2A: (#9711)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply

(#9712) Language Group Specify - Canadian French

(No Longer Available as of July 30, 2010)

Canadian French language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 9125-F2A: (#9712)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply

(#9714) Language Group Specify - Japanese

(No Longer Available as of July 30, 2010)

Japanese language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 9125-F2A: (#9714)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply

(#9715) Language Group Specify - Traditional Chinese (Taiwan)

(No Longer Available as of July 30, 2010)

Traditional Chinese language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 9125-F2A: (#9715)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply

(#9716) Language Group Specify - Korean

(No Longer Available as of July 30, 2010)

Korean language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 9125-F2A: (#9716)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply

(#9718) Language Group Specify - Turkish

(No Longer Available as of July 30, 2010)

Turkish language group for nomenclature and publications.

  • Attributes provided: None
  • Attributes required: None
  • For 9125-F2A: (#9718)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply

(#9719) Language Group Specify - Hungarian

(No Longer Available as of July 30, 2010)

Hungarian language group for Nomenclature and Standard Publications.

  • Attributes provided: none
  • Attributes required: none
  • For 9125-F2A: (#9719)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply

(#9720) Language Group Specify - Slovakian

(No Longer Available as of July 30, 2010)

Slovakian language group for Nomenclature and Standard Publications.

  • Attributes provided: none
  • Attributes required: none
  • For 9125-F2A: (#9720)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply

(#9721) Language Group Specify - Russian

(No Longer Available as of July 30, 2010)

Russian language group for nomenclature and standard publications.

  • Attributes provided: None
  • Attributes required: None
  • For 9125-F2A: (#9721)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply

(#9722) Language Group Specify - Simplified Chinese (PRC)

(No Longer Available as of July 30, 2010)

Simplified Chinese language group for nomenclature and standard publications.

  • Attributes provided: None
  • Attributes required: None
  • For 9125-F2A: (#9722)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply

(#9724) Language Group Specify - Czech

(No Longer Available as of July 30, 2010)

Czech language group for nomenclature and standard publications.

  • Attributes provided: None
  • Attributes required: None
  • For 9125-F2A: (#9724)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply

(#9725) Language Group Specify -- Romanian

(No Longer Available as of July 30, 2010)

Romanian language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 9125-F2A: (#9725)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply

(#9726) Language Group Specify - Croatian

(No Longer Available as of July 30, 2010)

Croatian language group for Nomenclature and Standard Publications.

  • Attributes provided: Language specify
  • Attributes required: None
  • For 9125-F2A: (#9726)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply

(#9727) Language Group Specify -- Slovenian

(No Longer Available as of July 30, 2010)

Slovenian language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 9125-F2A: (#9727)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply

(#9728) Language Group Specify - Brazilian Portuguese

(No Longer Available as of July 30, 2010)

Brazilian Portuguese language group for Nomenclature and Standard Publications.

  • Attributes provided: Language specify
  • Attributes required: None
  • For 9125-F2A: (#9728)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply

(#9729) Language Group Specify - Thai

(No Longer Available as of July 30, 2010)

Thai language group for Nomenclature and Standard Publications.

  • Attributes provided: Language specify
  • Attributes required: None
  • For 9125-F2A: (#9729)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply

Feature exchanges

Not available.
Back to topBack to top
 

Accessories

None.

Customer replacement parts

None.
Back to topBack to top
 

Machine elements

Not available.
Back to topBack to top
 

Supplies

None.

Supplemental media

None.

Trademarks

(R), (TM), * Trademark or registered trademark of International Business Machines Corporation.

** Company, product, or service name may be a trademark or service mark of others.

Windows is a trademark of Microsoft Corporation.
 © IBM Corporation 2014.
Back to topBack to top