Feedback


Family 9405+01 IBM System i Express Configuration 1-way Server with

IBM United States Sales Manual
Revised:  April 08, 2014.

Table of contents
TOC Link Product life cycle dates TOC Link Publications
TOC Link Abstract TOC Link Features
TOC Link Highlights TOC Link Accessories
TOC Link Description TOC Link Machine elements
TOC Link Models TOC Link Supplies
TOC Link Technical description  

 
POWER5
Product life cycle dates
Type Model Announced Available Marketing Withdrawn Service Discontinued
9405-520 2004/10/152004/11/19 2008/07/08 -

Back to topBack to top
 
Abstract

The 9405 IBM System i 520 Express Configurations include sufficient hardware and software to be a solid foundation for small or medium-sized business computing.

IBM Business Partners can enhance the standard configurations with additional features and can offer a wide selection of application solutions, from cross-industry general accounting to industry-specific vertical solutions, all tailored to the specific needs of the small and medium-sized enterprise. A Capacity on Demand option, Accelerator for System i5, expands flexibility for select configurations.

Note: The 9405 520 Express Configurations are available through Business Partners only and are not available from IBM directly.

Model abstract 9405-520

The IBM 9405 i5 Express Configuration Model 520 is a 1-way server based on IBM POWER5 and advanced POWER5 technology with i5/OS, 70 to 280GB of disk, 1 to 4GB of memory, internal CD/DVD/Tape drives, Twinax, LAN, and communication ports, Specified software licenses, RAID configurations, Eight memory slots, Six PCI-X slots, Eight disk slots (four optionally enabled), one half-high slot for tape devices (30GB QIC drive included), Two slimline slots for DVD drives (one DVD ROM drive included), and language support.
Back to topBack to top
 

Highlights

IBM System i Express Configurations for small and medium-sized enterprises

  • Delivers key elements of your IT infrastructure in a single server with:
    • Supporting hardware
    • Software
    • Maintenance
    • Support
    • Very attractive price

  • Machine type: 9405

Two console choices are available for purchase when you initially order a 520 Express Configuration:

  • Thin console for System i5 (using the HMC port on the 520 system unit)
  • Operations Console (using an embedded Ethernet port)

Because these console options do not require an I/O processor (IOP) and do not use the PCI slots used by the previously available twinax console, you gain up to two additional PCI slots in the system unit. The twinaxial solution is available for clients who require it.

The thin console is a single-byte character set (SBCS) device. It does not support double-byte character set (DBCS) or bidirectional languages. The following keyboard languages are supported:

Country                Keyboards
---------------        ------------------------------------
Austria                German/Austrian
Belgium                Belgian/French, Dutch
Canada                 U.S. English, Canadian French
Denmark                Danish
France                 French, Swiss French/German
Germany                German/Austrian, Swiss French/German
Ireland                U.K. English
Italy                  Italian, Swiss French/German
Netherlands            Dutch
Norway                 Norwegian
Portugal               Portuguese
Spain                  Spanish
Sweden                 Swedish/Finnish
Switzerland            Swiss French/German, Italian
United Kingdom         U.K. English
United States          U.S. English
 

Back to topBack to top
 
Description

IBM System i 520 Express Configurations Overview

The 9405 model 520 Express Configurations are tailored specifically to small and medium-sized enterprises and are available in several configurations/offerings. They are 1-way servers based on POWER5 and advanced POWER5 technology. All 9405 520 offerings/configurations include hardware and i5/OS.

These attractively priced servers include:

  • i5/OS
  • 70 to 280GB of disk
  • 1 to 4GB of memory
  • 30GB QIC tape drive
  • DVD-ROM drive
  • Twinax, LAN, and communication ports
  • Specified software licenses
  • RAID configurations

The 9405 model 520 Express Configuration is a 1-way server based on IBM POWER5 technology. Each 520 system unit has:

  • Eight memory slots
  • Six PCI-X slots
  • Eight disk slots (four optionally enabled)
  • One half-high slot for tape devices
  • Two slimline slots for DVD drives

Optionally, the other four disk slots can be enabled in the system unit:

  • Two 1Gbps/100Mbps/10Mbps Ethernet LAN ports
  • Two HSL-2/RIO-G ports (for one HSL/RIO loop)
  • Two SPCN ports
  • Two serial ports
  • Two HMC ports
  • Two USB ports

i5/OS V5R3 and V5R4 support the use of all of the preceding hardware elements except one slimline slot, two serial ports, and two USB ports. These components are reserved for other operating systems running on the 520.

i5 520 Express Configurations that implement partitioning require an IBM 7310 Hardware Management Console (HMC) if they include:

  • Multiple i5/OS partitions
  • AIX partitions
  • Linux partitions that require more function than provided by i5/OS virtual partition manager.

The HMC is not required for a partition to run, but it is required for the server to create, define, and change an HMC-created partition. An HMC can also serve as an i5/OS system console.

Multiple partitions and multiple POWER5/advanced POWER5 processor- based servers can be supported by an HMC, located locally or remotely attached to the System i5 solution.

System i5 520 Express Configurations are available only as deskside servers at initial order. They can later be converted to a rack-mount configuration, or additional features can be added by chargeable MES orders. Configurations are shipped from IBM with a twinaxial workstation controller and the system console specification as a twinaxial workstation.

Optional MES features/function

RAID hot spare

RAID hot spare is a disk protection option. In the event of a disk drive failure, a spare disk is dynamically assigned to take over the failed disk's role, and the rebuilding operation is started. Before hot spare, if a disk failed in a RAID-5 array, the array was not protected against a second disk failure until the failed disk was physically replaced and the data contents rebuilt on the replacement disk. Using the hot spare disk drive, a failed drive error is now handled in parallel to the automatic system response. With the system's existing hot plug or concurrent maintenance capability, the failed drive can be replaced without taking the system down. The replacement drive then takes over the role of standing by as the hot spare.

The RAID hot spare disk drive is plugged into the system and does not contain any data until it takes over for a failed disk drive. Therefore, it requires a disk slot. The hot spare disk drive is associated with a specific controller. Assuming all drives are the same capacity, one hot spare disk drive can stand by, protecting all the arrays managed by the disk controller.

Depending on the level of protection that you want, you may have more than one disk drive per disk controller. This would help protect against the combined sequential failures of more than two (RAID-5) or three (RAID-6) disk failures. It would not protect against the nonsequential failures where multiple drives failed at one time, or if another failure occurred when the hot spare drive rebuilding was not yet completed in a RAID-5 array.

When ordering a new system from IBM, you can request that RAID hot spare be implemented by IBM manufacturing by specifying #0347. This feature is assumed by IBM to be systemwide, unless you are defining protection by partition. One hot spare disk drive will be assigned per disk controller except in the EXP24 Disk Enclosure. The EXP24 1.5 GB Disk Controller (#5739/5778/5799/5800/5781/5782 or CCIN 571F) will have one hot spare disk if there are 18 or fewer drives in the EXP24 or two hot spare disk drives if there are 19 to 24 drives.

You can control the use of hot spare drives with more granularity than what #0347 hot spare specify indicates. You can assign as many hot spare drives as desired to each specific IOA or controller. This can be useful if you have separate auxiliary storage pools (ASPs) for which you want different levels of protection.

i5/OS V5R4 with machine code V5R4M5, or later, is required. It is supported with disk controllers with a write cache of 757 MB or more (#2757/5581/5591, #2780/5580/5590, #5582/5583/5738/5777, #5739/5778/5799/5800/5781/5782), disk controllers with 40 MB (#5703/2782) and 90 MB (#5737/5776) write cache, and with the imbedded disk controllers of the models 515, 520, 525, 550, and 570 with a 16 to 40 MB write cache card (#5709/5726/9509/5727/5728/9510).

WAN smart IOAs

Smart IOAs save PCI slots by not using an IOP. With i5/OS V5R4 and machine code or firmware of V5R4M5 or later, existing PCI WAN adapters are enhanced to no longer require an IOP. The following features help IBM configurator tools understand how the IOA is being used.

  • #6805 PCI 2-Line WAN IOA no IOP (same PCI card as #2742)

  • #6808 PCI 4-Modem IOA no IOP (same PCI card as #2805)

  • #6809 PCI 4-Modem IOA no IOP (CIM) (same PCI card as #2806)

  • #6833/9933 PCI 2-Line WAN with Modem no IOP (same PCI card as #2793/9793/6803(1)/9493(1))

  • #6834/9934 PCI 2-Line WAN with Modem no IOP (CIM) (same PCI card as #2794/9794/6804(1)/9494(1))

Note: (1) A lower level of function as an IOP-less adapter; it is designated by this pre-V5R4M5 feature number with a different feature name.

WAN smart IOAs do not support SNA or SDLC protocols. However, support of SNA applications over other protocols can be provided through the no- charge Enterprise Extender function of i5/OS V5R4. For more information, visit:

http://www.ibm.com/systems/support/i/planning/upgrade/futurehdwr.html

The Operations Console - Direct Attach (commonly called Ops Console), is supported with V5R4M5 machine code using #6833/9933 or #6834/9934. This i5/OS console option uses a special cable #0367 attached to a user- supplied Windows workstation to the smart IOA 2-Line WAN with Modem IOA.

Internet SCSI (iSCSI) is a networking standard for attachment of systems to storage using industry-standard networking protocols and equipment. iSCSI commands are sent across a network in TCP/IP packets.

iSCSI Host Bus Adapters for System i5 leverage industry-standard technology to provide a simpler, more cost-effective way to attach xSeries systems and BladeCenter to the System i5 Model 520. You can take advantage of xSeries and BladeCenter reliability and scalability to support Windows applications while uniquely exploiting System i5 virtual storage, networking, and tape resources.

10 Gbps Ethernet adapter enables high-speed communication.

Intelligent PDU+

Continuous power usage data can be collected on your System i configuration via a #7109 intelligent power distribution unit (PDU+). The intelligent PDU+ includes 12 electrical outlets per PDU for the #0551 1.8 m rack, #0553 2.0 m rack, and #0555 25U rack. The #7109 is interchangeable with the #7188 PDU. However, only the #7109 PDU+ can collect usage data. Using software such as IBM Systems Director Active Energy Manager, data administrators can use the information to monitor the power consumption of the data center at various times of the day, week, or month. They can use that information to identify anomalies and manage loads when electrical demands or costs are high. Electrical usage information correlates to heat output, so the data can also offer insights into air conditioning requirements.

SAS disk drives

SAS disk drives used on POWER5/POWER5+ systems are placed in the EXP 12S SAS disk drawer (#5886). Either 139.5 GB (#3677), 283.7 GB (#3678), or 428.43 GB (#3658) SAS drives can be used. These 3.5-inch SAS disk drives are driven by the PCI-X DDR 1.5 GB Cache RAID Adapter (#5904 or #5908). Features 5904 and 5908 are the same adapter, but feature 5908 includes a blind swap cassette for use in the feature 5790 I/O drawer. The PCI-X DDR 1.5 GB Cache RAID Adapter (#5904 or #5908) connects to an EXP 12S disk drawer via a YO SAS cable.

Normal POWER5/POWER5+ disk protection rules apply. Disk drives should be protected by using either RAID 5, RAID 6, or mirroring. Hot spare is also supported. The 1.5 GB write cache of the disk controller is protected by an auxiliary write cache built into the double-slot adapter in addition to a built-in battery that can be hot-plugged. SAS disk drives can be mirrored against SCSI disk drives of similar capacity. For example, the 139.5 GB SAS drive can be mirrored against the 141.14 GB SCSI drive.

The PCI-X DDR 1.5 GB Cache RAID Adapter (#5904 or #5908) cannot be placed in the POWER5 system unit. It can be placed in an I/O tower or drawer attached to the system unit. The following table shows the supported hardware and the maximum number of adapters that can be used with the hardware.

Supported                    Supported Number
hardware                     feature   adapters Location
---------------------------  --------- -------- -------------------
#0595/5095 I/O drawer/tower  #5904     Max 2    Slots C1/C2, C2/C3,
                                                C3/C4
#5094/5096/8094 I/O
expansion unit               #5904     Max 1    Slots C14/C15
 
#5294/5296/8294 I/O          #5904     Max 2    Slots C14/C15
expansion unit                                  (1 upper/1 lower)
 
#5790 I/O drawer             #5908     Max 2    Slots C1/C2, C2/C3,
                                                C4/C5, C5/C6
 

EXP 12S SAS disk drawer

The EXP 12S SAS disk drawer (#5886) is a 2U (2 EIA) SAS disk drawer that is placed in a 19-inch rack. It supports up to 12 hot-swap SAS disk drives (#3677, #3678, and #3658) and includes redundant power supplies. These 12 slots are all controlled by one disk controller. The feature 5886 disk drawer has no PCI slots, and the disk controller (#5904 or #5908) that runs its disk slots is located in PCI-X slots in the I/O drawer or tower. SAS YO cables (#3691, #3692, #3693, and #3694) of 1.5 M, 3 M, 6 M, or 15 M length connect the feature 5886 EXP 12S disk drawer and the disk controller.

Smart Fibre Channel controller

Smart Fibre Channel IOAs can be used on POWER5/POWER5+ systems to attach to the IBM System Storage DS8000 (DS8100 or DS8300) or DS6800 under IBM i 6.1. This PCI-X adapter is the two-port 4 Gb Fibre Channel (#5749) previously announced on POWER6 systems. Feature 5749 does not support the attachment of an IBM i load source on POWER5 systems. Continue to use the IOP-based Fibre Channel adapters for this purpose.

The smart Fibre Channel adapter, feature 5749, is supported in the system unit or the following I/O drawers with PCI-X slots.

  • #0588
  • #0595
  • #5088
  • #5094
  • #5095
  • #5096
  • #5294
  • #5296
  • #8294
  • #9094
  • #9194

Feature 5749 is not supported in earlier I/O drawers with only PCI slots and no PCI-X slots. For example:

  • #0578
  • #5074
  • #5078
  • #5079

Attaching tape drives or libraries via the feature 5749 Fibre Channel adapters on POWER5/POWER5+ systems is not supported.

Summary of IBM System i 520 Express Configurations

Entry, Entry Plus, Growth, and Turbo configurations feature mirrored disk protection.

Entry Plus with RAID, Growth with RAID, and Turbo with RAID configurations feature RAID disk protection.

                       Entry/      Entry Plus           Growth  Maximum
                       Entry Plus  w/RAID      Growth   w/RAID  Supported
                       ----------  ----------  ------   ------  ---------
Configuration feature   7140/7141     7142      7148     7143
Server feature             0970       0970      0970     0970
Processor group             P05        P05       P10      P10
Processor(s)             8325x1     8325x1    8327x1   8327x1
                        (1-Way)    (1-Way)   (1-Way)  (1-Way)
Processor CPW               600        600      1200     1200   3100/3800
5250 OLTP                    30         30        60       60          60
Main storage                1GB        1GB       2GB      2GB        32GB
Disk storage            140.6GB    281.2GB   140.6GB  281.2GB        39TB
Disk speed (rpm)            15K        15K       15K      15K
Disk arms                     2          4         2        4         278
Integrated RAID-5 and
write cache                   0          1         0        1           1
Internal CD/DVD/tape          2          2         2        2          14
(internal tape 30GB QIC
and DVD included)
Ext tape/optical/CD/DVD       0          0         0        0          36
Physical packaging
    HSL-2/RIO-G loops         0          0         0        0           1
    HSL-2/RIO-G ports         0          0         0        0           2
    I/O towers/drawers        0          0         0        0           6
    PCI card slots            6          6         6        6          90
Twinaxial controllers         1          1         1        1          48
Twinaxial devices             0          0         0        0        1920
Communication lines           2          2         2        2         192
LAN ports                     2          2         2        2          36
Windows integration
   Int xSeries Servers        0          0         0        0          18
   Int xSeries Adapters       0          0         0        0           8
                                     Turbo      Maximum
                          Turbo      w/RAID     Supported
                          ------     ------     ---------
Configuration feature      7144       7152
 
Server feature             0970       0970
 
Processor group             P10        P10
 
Processors               8327x1     8327x1
                        (1-Way)    (1-Way)
 
Processor CPW              3800       3800       3800
5250 OLTP                    60         60         60
Main storage                4GB        4GB       32GB
Disk storage            140.6GB    281.2GB       39TB
Disk speed (rpm)            15K        15K        15K
Disk arms                     2          4        278
Integrated RAID-5 and
write cache                   0          1          1
Internal CD/DVD/Tape          2          2         14
(Internal Tape 30GB QIC
and DVD included)
Ext Tape/Optical/CD/DVD       0          0         36
Physical packaging
    HSL-2/RIO-G Loops         0          0          1
    HSL-2/RIO-G Ports         0          0          2
    I/O Towers/Drawer         0          0          6
    PCI Card Slots            6          6         90
Twinaxial controller          1          1         48
Twinaxial devices             0          0       1920
Communication lines           2          2         60
LAN Ports                     2          2         36
Windows integration
   Int xSeries Servers        0          0         18
   Int xSeries Adapters       0          0          8
 

Model 520 Express Configuration Descriptions

Model 520 Express Configuration (#7140) - Entry

Function

  • Support for multiple operating systems (i5/OS, AIX 5L, and Linux)
  • Support for Web modernization (enhanced WebFacing tool support)
  • Support for LPAR (up to two partitions as shipped or up to 10 partitions per processor if using Accelerator)
  • Support for 5250 OLTP (30 CPW)

Software

  • Licensing for i5/OS (one processor license)
  • IBM Web Enablement (5722-WE2)
  • IBM Director for iSeries (5733-DR1)

Hardware

  • 1GB memory
  • Two 70GB 15k rpm disk drives
  • 30GB QIC tape drive
  • One DVD-ROM
  • One I/O processor (IOP)
  • One twinaxial controller

Model 520 Express Configuration (#7141) - Entry Plus

Function

  • Support for multiple operating systems (i5/OS, AIX 5L, and Linux)
  • Support for Web modernization (enhanced WebFacing tool support)
  • Support for LPAR (up to two partitions as shipped or up to 10 partitions per processor if using Accelerator)
  • Support for 5250 OLTP (30 CPW)

Software

  • Licensing for i5/OS (one processor license)
  • IBM Web Enablement (5722-WE2)
  • IBM Director for iSeries (5733-DR1)
  • IBM DB2 Web Query for System i (5733-QU2)
  • Licensing for DB2 Query Manager and SQL Toolkit (5722-ST1)
  • Licensing for iSeries Access (five user licenses) (5722-XW1)
  • Licensing for WebSphere Development Studio (5722-WDS)*

Hardware

  • 1GB memory
  • Two 70GB 15k rpm disk drives
  • 30GB QIC tape drive
  • One DVD-ROM
  • One I/O processor (IOP)
  • One twinaxial controller

Model 520 Express Configuration (#7142) - Entry Plus with RAID

Function

  • Support for multiple operating systems (i5/OS, AIX 5L, and Linux)
  • Support for Web modernization (enhanced WebFacing tool support)
  • Support for LPAR (up to two partitions as shipped or up to 10 partitions per processor if using Accelerator)
  • Support for 5250 OLTP (30 CPW)

Software

  • Licensing for i5/OS (one processor license)
  • IBM Web Enablement (5722-WE2)
  • IBM Director for iSeries (5733-DR1)
  • IBM DB2 Web Query for System i (5733-QU2)
  • Licensing for DB2 Query Manager and SQL Toolkit (5722-ST1)
  • Licensing for iSeries Access (five user licenses) (5722-XW1)
  • Licensing for WebSphere Development Studio (5722-WDS)*

Hardware

  • 1GB memory
  • Four 70GB 15k rpm disk drives (RAID-5 disk protection turned on)
  • One integrated write cache and RAID-5 enabler card
  • 30GB QIC tape drive
  • One DVD-ROM
  • One I/O processor (IOP)
  • One twinaxial controller

Model 520 Express Configuration (#7148) - Growth

Function

  • Support for multiple operating systems (i5/OS, AIX 5L, and Linux)
  • Support for Web modernization (enhanced WebFacing tool support)
  • Support for LPAR (up to three partitions as shipped or up to 10 partitions per processor if using Accelerator)
  • Support for 5250 OLTP (60 CPW)

Software

  • Licensing for i5/OS (one processor license)
  • IBM Web Enablement (5722-WE2)
  • IBM Director for iSeries (5733-DR1)
  • IBM DB2 Web Query for System i (5733-QU2)
  • Licensing for DB2 Query Manager and SQL Toolkit (5722-ST1)
  • Licensing for iSeries Access (five user licenses) (5722-XW1)
  • Licensing for WebSphere Development Studio (5722-WDS)*

Hardware

  • 2GB memory
  • Two 70GB 15k rpm disk drives
  • 30GB QIC tape drive
  • One DVD-ROM
  • One I/O processor (IOP)
  • One twinaxial controller

Model 520 Express Configuration (#7143) - Growth with RAID

Function

  • Support for multiple operating systems (i5/OS, AIX 5L, and Linux)
  • Support for Web modernization (enhanced WebFacing tool support)
  • Support for LPAR (up to three partitions as shipped or up to 10 partitions per processor if using Accelerator)
  • Support for 5250 OLTP (60 CPW)

Software

  • Licensing for i5/OS (one processor license)
  • IBM Web Enablement (5722-WE2)
  • IBM Director for iSeries (5733-DR1)
  • IBM DB2 Web Query for System i (5733-QU2)
  • Licensing for DB2 Query Manager and SQL Toolkit (5722-ST1)
  • Licensing for iSeries Access (five user licenses) (5722-XW1)
  • Licensing for WebSphere Development Studio (5722-WDS)*

Hardware

  • 2GB memory
  • Four 70GB 15k rpm disk drives (RAID-5 disk protection turned on)
  • One integrated write cache and RAID-5 enabler card
  • 30GB QIC tape drive
  • One DVD-ROM
  • One I/O processor
  • One twinaxial adapter

Model 520 Express Configuration (#7144) - Turbo

Function

  • Support for multiple operating systems (i5/OS, AIX 5L, and Linux)
  • Support for Web modernization (enhanced WebFacing tool support)
  • Support for LPAR (up to 10 partitions per processor)
  • Support for 5250 OLTP (60 CPW)

Software

  • Licensing for i5/OS (one processor license)
  • IBM Web Enablement (5722-WE2)
  • IBM Director for iSeries (5733-DR1)
  • IBM DB2 Web Query for System i (5733-QU2)
  • Licensing for DB2 Query Manager and SQL Toolkit (5722-ST1)
  • Licensing for iSeries Access (five user licenses) (5722-XW1)
  • Licensing for WebSphere Development Studio (5722-WDS)*

Hardware

  • 4GB memory
  • Two 70GB 15k rpm disk drives
  • 30GB QIC tape drive
  • One DVD-ROM
  • One I/O processor (IOP)
  • One twinaxial controller

Model 520 Express Configuration (#7152) - Turbo with RAID

Function

  • Support for multiple operating systems (i5/OS, AIX 5L, and Linux)
  • Support for Web modernization (enhanced WebFacing tool support)
  • Support for LPAR (up to 10 partitions per processor)
  • Support for 5250 OLTP (60 CPW)

Software

  • Licensing for i5/OS (one processor license)
  • IBM Web Enablement (5722-WE2)
  • IBM Director for iSeries (5733-DR1)
  • IBM DB2 Web Query for System i (5733-QU2)
  • Licensing for DB2 Query Manager and SQL Toolkit (5722-ST1)
  • Licensing for iSeries Access (five user licenses) (5722-XW1)
  • Licensing for WebSphere Development Studio (5722-WDS)(1)

Hardware

  • 4GB memory
  • Four 70GB 15k rpm disk drives (RAID-5 disk protection turned on)
  • One integrated write cache and RAID-5 enabler card
  • 30GB QIC tape drive
  • One DVD-ROM
  • One I/O processor (IOP)
  • One twinaxial controller

Note: (1) WebSphere Development Studio is a required component of selected Express Configurations and is priced separately from the Express Configuration feature code.

Additional considerations

The 9405 520 Express Configurations with the 600/30 CPW/OLTP processors can be upgraded to the 1,200/60 CPW/OLTP processors with the following conversions:

  • Configuration feature #7142 to feature #7143
  • Configuration feature #7140 to feature #7148
  • Configuration feature #7141 to feature #7148

The conversion includes only the 1,200/60 CPW processor card. As with any edition upgrade, the other hardware and software content defined in the richer edition is not included in the upgrade price.

There are no feature conversions into or out of server feature #0970.

Section 508 of the US Rehabilitation Act

IBM System i5 servers are capable, when used in accordance with IBM's associated documentation, of satisfying the applicable requirements of Section 508 of the Rehabilitation Act, provided that any assistive technology used with the product properly interoperates with it.
Back to topBack to top
 

Models

Model summary matrix

Model Server Type HDD Memory Drives Slots Misc.
520 1-way server based on IBM POWER5 technology 70 to 140 GB 1 to 2GB 30GB QIC tape drive, DVD-ROM drive Eight memory slots, Six PCI-X slots, Eight disk slots (four enabled), One half-high slot for tape devices, Two slimline slots for DVD drives i5/OS, Twinax, LAN, and communication ports, Specified software licenses, RAID configurations

Customer setup (CSU)

Model 520 initial installation is customer setup.

Some features are designated CSU. On MES orders where all features are CSU, the customer can install all features. IBM installation is available for a charge, under normal service contracts. On MES orders that contain mix of IBM and CSU features, the customer may choose to have the IBM service representative install all features (including those designated as CSU).

The customer is responsible for installation of external cables, displays, printers, and modems. Customers may request IBM service personnel to perform these activities for a charge.

Devices supported

The following external machine types are supported on the 9405 model 520. This list is not all inclusive. Many devices are supported through standard ports. Please refer to the sales manual of the external machine type.

         |5|  X = SUPPORTED DEVICE
         |2|
         |0|
         | |
  MT-MOD | |        DESCRIPTION
---------+-+--------Disk---------------------------------------------
1710-10U |X| IBM System Storage EXP100 Expansion Unit
1722-60U |X| IBM System Storage DS4300 Disk System
1724-100 |X| IBM System Storage DS4100 Disk System
1740-1RU |X| IBM 1740-1RU
1742-1RU |X| IBM 1742-1RU
1742-90U |X| IBM System Storage DS4500 Disk System
2105-800 |X| IBM 2105-800
2105-F10 |X| IBM 2105-F10
2105-F20 |X| IBM 2105-F20
7133-D40 |X| IBM Serial Disk System Advanced Model D40
7133-T40 |X| IBM Serial Disk System Advanced Model T40
7204-419 |X| 18.2 GB External Disk Drive
7204-518 |X| IBM 7204-518
7204-536 |X| IBM 7204-536
7204-573 |X| IBM 7204-573
7204-646 |X| IBM 7204-646
7205-440 |X| IBM 7205-440
---------+-+--------Displays-----------------------------------------
6546-00E |X| G52 Display
6546-00N |X| G52 Display
6546-01E |X| G52 Display
6546-01S |X| G52 Display
6546-0AE |X| G54 Display
6546-0AN |X| G54 Display
6546-0BE |X| G54 Display
6546-0BN |X| G54 Display
6546-0BS |X| G54 Display
6546-21N |X| G52 Display
6546-2BN |X| G54 Display
6546-31N |X| G52 Display
6546-4AN |X| G54 Display
6546-6BN |X| G54 Display
7042-C06 |X| IBM 7042-C06
7042-C07 |X| IBM 7042-C07
7042-CR4 |X| IBM 7042-CR4
7310-C03 |X| IBM 7310-C03
7310-C04 |X| IBM 7310-C04
7310-C06 |X| IBM 7310-C06
7310-CR2 |X| IBM 7310-CR2
7310-CR4 |X| IBM 7310-CR4
7315-C01 |X| IBM 7315-C01
7315-C03 |X| IBM 7315-C03
7316-TF2 |X| IBM 7316-TF2
7316-TF3 |X| IBM 7316-TF3
---------+-+--------Expansion Cabinets-------------------------------
2104-DS4 |X| IBM 2104-DS4
2104-TS4 |X| IBM 2104-TS4
2109-C36 |X| IBM 2109-C36
7014-T00 |X| IBM 7014-T00
7014-T42 |X| IBM 7014-T42
7311-D10 |X| IBM 7311-D10
7311-D11 |X| IBM 7311-D11
7311-D20 |X| IBM 7311-D20
---------+-+--------Power--------------------------------------------
9910-E30 |X| Powerware 9125 3KVA Tower/Rack
9910-E33 |X| POWERWARE 5125 3KVA RACK-MOUNT
9910-E64 |X| Powerware 9125 6KVA Tower/Rack
9910-E65 |X| Powerware 5125 5KVA Rack Mount
9910-P10 |X| PW9125 1000VA 110-127 LV NA
9910-P11 |X|
9910-P13 |X| PW5115 1.4kVA 110-127V LV NA
9910-P14 |X| PW5115 1.4kVA 220-240V HV WT
9910-P15 |X| PW9125 1.5kVA 110-127V LV NA
9910-P16 |X| PW9125 1.5kVA 220-240V HV WT
9910-P30 |X| PW9125 3KVA Rack/Tower
9910-P33 |X| 9910 P33 Powerware 5125 3000VA
9910-P64 |X| PW9125 6kVA Rack/Tower
9910-P65 |X| PW5125 5kVA
---------+-+--------SCSI Devices-------------------------------------
3995-C40 |X| IBM 3995-C40
3995-C60 |X| IBM 3995-C60
7210-020 |X| IBM 7210-020
7210-025 |X| IBM 7210-025
7210-030 |X| IBM 7210-030
---------+-+--------Storage Network Devices--------------------------
2105-750 |X| IBM 2105-750
2145-4F2 |X| IBM 2145-4F2
---------+-+--------Switch-------------------------------------------
2005-H08 |X| IBM TotalStorage SAN Switch H16
2005-H16 |X| IBM TotalStorage SAN Switch H16
2031-016 |X| IBM 2031-016
2031-032 |X| IBM 2031-032
2031-216 |X| IBM 2031-216
2031-224 |X| IBM 2031-224
2031-232 |X| IBM 2031-232
2031-L00 |X| IBM 2031-L00
2032-064 |X| IBM 2032-064
2032-140 |X| IBM 2032-140
2034-212 |X| IBM 2034-212
2042-001 |X| IBM 2042-001
2042-128 |X| IBM 2042-128
2042-256 |X| IBM 2042-256
2061-020 |X| IBM 2061-020
2061-040 |X| IBM 2061-040
2062-D01 |X| IBM 2062-D01
2062-D04 |X| Cisco MDS 9506 MultilaIayer Director
2062-D07 |X| Cisco MDS 9509 MultilaIayer Director
2109-F16 |X| IBM 2109-F16
2109-F32 |X| IBM 2109-F32
2109-M12 |X| IBM 2109-M12
2109-M14 |X| IBM 2109-M14
---------+-+--------Tape---------------------------------------------
3494-B10 |X| IBM 3494-B10
3494-B18 |X| IBM 3494-B18
3494-B20 |X| IBM 3494-B20
3494-D10 |X| IBM 3494-D10
3494-D12 |X| IBM 3494-D12
3494-D14 |X| IBM 3494-D14
3494-D22 |X| IBM 3494-D22
3494-D24 |X| IBM 3494-D24
3494-HA1 |X| IBM 3494-HA1
3494-L10 |X| IBM 3494-L10
3494-L12 |X| IBM 3494-L12
3494-L14 |X| IBM 3494-L14
3494-L22 |X| IBM 3494-L22
3494-S10 |X| IBM 3494-S10
3570-B00 |X| IBM 3570 Model B00
3570-B01 |X| IBM 3570 Model B01
3570-B02 |X| IBM 3570 Model B02
3570-B11 |X| IBM 3570 Model B11
3570-B12 |X| IBM 3570 Model B12
3570-B1A |X| IBM 3570 Model B1A
3570-C00 |X| IBM Magstar MP 3570 Tape Library Model C00
3570-C01 |X| IBM Magstar MP 3570 Tape Library Model C01
3570-C02 |X| IBM Magstar MP 3570 Tape Library Model C02
3570-C11 |X| IBM Magstar MP 3570 Tape Library Model C11
3570-C12 |X| IBM Magstar MP 3570 Tape Library Model C12
3575-L06 |X| 3575 Magstar Tape Library Dataserver Model L06
3575-L12 |X| 3575 Magstar Tape Library Dataserver Model L12
3575-L18 |X| 3575 Magstar Tape Library Dataserver Model L18
3575-L24 |X| 3575 Magstar Tape Library Dataserver Model L24
3575-L32 |X| 3575 Magstar Tape Library Dataserver Model L32
3580-H11 |X| IBM 3580-H11
3580-H13 |X| IBM 3580-H13
3580-H23 |X| IBM 3580-H23
3580-L11 |X| IBM 3580-L11
3580-L13 |X| IBM 3580-L13
3580-L23 |X| IBM 3580-L23
3581-F28 |X| IBM 3581-F28
3581-H13 |X| IBM 3581-H13
3581-H17 |X| IBM 3581-H17
3581-H23 |X| IBM 3581-H23
3581-L13 |X| IBM 3581-L13
3581-L17 |X| IBM 3581-L17
3581-L23 |X| IBM 3581-L23
3581-L28 |X| IBM 3581-L28
3582-L23 |X| IBM 3582-L23
3583-L18 |X| IBM 3583-L18
3584-D22 |X| IBM 3584-D22
3584-D32 |X| IBM 3584-D32
3584-D52 |X| IBM 3584-D52
3590-B11 |X| IBM 3590-B11
3590-B1A |X| IBM 3590-B1A
3590-E11 |X| IBM 3590-E11
3590-E1A |X| IBM 3590-E1A
3590-H11 |X| IBM 3590-H11
3590-H1A |X| IBM 3590-H1A
3592-J1A |X| IBM TotalStorage Enterprise Tape Drive 3592
3599-021 |X| IBM 3599-021
7206-220 |X| IBM 7206-220
7206-336 |X| IBM 7206-336
7206-VX2 |X| IBM 7206-VX2
7207-122 |X| IBM 7207-122
7207-330 |X| IBM 7207-330
7208-341 |X| IBM 7208-341
7208-342 |X| IBM 7208-342
7208-345 |X| IBM 7208-345
7212-102 |X| IBM 7212-102
7212-312 |X| IBM 7212-312
7332-220 |X| IBM 4MM DDS-4 Tape Cartridge Autoloader Model 220
7334-410 |X| IBM 8mm Tape Library Model 410
7337-360 |X| IBM DLT8000 Digital Linear Tape Library Model 360
 

Cables Supported

Type Mod Feat Withdrawn  Cable Type      Description
---- --- ---- ---------- --------------- ----------------------------
9405 520 0325 Yes        Miscellaneous   IPCS Extension Cables for NT
9405 520 0348            WAN             V.24/EIA232 20-Ft PCI Cable
9405 520 0353            WAN             V.35 20-Ft PCI Cable
9405 520 0356 Yes        WAN             V.36 20-Ft PCI Cable
9405 520 0359            WAN             X.21 20-Ft PCI Cable
9405 520 0367            Miscellaneous   Operations Console PCI Cable
9405 520 0371            FIBRE           LC-SC Adapter Kit (50um)
9405 520 0372            FIBRE           LC-SC Adapter Kit (62.5um)
9405 520 1025            WAN             Modem Cable - US/Canada
9405 520 1307 Yes        Rack Related    1.75m HSL-2/RIO-2 Cable
9405 520 1308            Rack Related    2.5m HSL-2/RIO-2 Cable
9405 520 1460            Rack Related    3m Copper HSL/RIO Cable
9405 520 1461            Rack Related    6m Copper HSL/RIO Cable
9405 520 1462            Rack Related    15m Copper HSL/RIO Cable
9405 520 1474            Rack Related    6m HSL/RIO to HSL2/RIO2 Cbl
9405 520 1475            Rack Related    10m HSL/RIO to HSL2/RIO2 Cbl
9405 520 1481            Rack Related    1.2m HSL-2/RIO-2 Cable
9405 520 1482            Rack Related    3.5m HSL-2/RIO-2 Cable
9405 520 1483            Rack Related    10m HSL-2/RIO-2 Cable
9405 520 1485            Rack Related    15m HSL-2/RIO-2 Cable
9405 520 1487            Rack Related    3m HSL/RIO to HSL2/RIO2 Cbl
9405 520 1827            Rack Related    Serial-UPS Conversion Cable
9405 520 1850 Yes        SCSI External   VHDCI to P Converter Cable
9405 520 1851 Yes        SCSI External   0.6m SCSI P-P Cable
9405 520 1852 Yes        SCSI External   2.5m SCSI P-P Cable
9405 520 1855 Yes        WAN             4-port EIA 232 Cable
9405 520 1860            ASYNC           ASYNC Terminal/Prt Cable
9405 520 1873            Miscellaneous   Dwr to Dwr Serial Cable
9405 520 1874            Miscellaneous   Rack to Rack Serial Cable
9405 520 1875            ASYNC           Serial Port Converter Cable
9405 520 2114 Yes        SCSI External   Ext Diff SCSI y-Cable
9405 520 2124            SCSI External   1m SCSI Cable
9405 520 2125            SCSI External   3m SCSI Cable
9405 520 2126            SCSI External   5m SCSI Cable
9405 520 2127            SCSI External   10m SCSI Cable
9405 520 2128            SCSI External   20m SCSI Cable
9405 520 2138            SCSI External   0.55m SCSI Cable
9405 520 2863 Yes        WAN             4-Port X.21 Cable
9405 520 2864 Yes        WAN             4-Port V.35 DTE Cable
9405 520 2877            Miscellaneous   4-Position Int Bus Cable
9405 520 2934            ASYNC           ASYNC Terminal/Prt Cable
9405 520 2936            ASYNC           ASYNC Modem Cable
9405 520 2951 Yes        WAN             V.24/EIA 232 Cable
9405 520 2952 Yes        WAN             V.35 Cable
9405 520 2953 Yes        WAN             V.36 Cable
9405 520 2954 Yes        WAN             X.21 Cable
9405 520 4242            Graphics        6-Ft Ext Cable for Display
9405 520 4256            Keyboard        Extender Cable for Keybd
9405 520 4263            SCSI Internal   Direct Attach Tape Cables
9405 520 4270 Yes        SCSI Internal   Ctlr to External Port Cable
9405 520 4353 Yes        Miscellaneous   8-Position H.100 Bus Cable
9405 520 4691 Yes        Miscellaneous   Rack Status Beacon Cable
9405 520 4692 Yes        Miscellaneous   Junction Box Cable
9405 520 6001 Yes        Rack Related    SPCN Power Cable - 2m
9405 520 6006            Rack Related    SPCN Power Cable - 3m
9405 520 6007            Rack Related    SPCN Power Cable - 15m
9405 520 6008            Rack Related    SPCN Power Cable - 6m
9405 520 6029 Yes        Rack Related    SPCN Power Cable - 30m
9405 520 7801            LAN             6m HMC Attachment Cable
9405 520 7802            LAN             15m HMC Attachment Cable
9405 520 8131 Yes        ASYNC           15-Ft Cluster Box Cable
9405 520 8132 Yes        ASYNC           9-Inch Cluster Box Cable
9405 520 8133            ASYNC           RJ45 to DB25 Interposer
9405 520 8136 Yes        ASYNC           Remote ASYNC Node (Rack)
9405 520 8137 Yes        ASYNC           Remote ASYNC Node
 

Model conversions

None.
Back to topBack to top
 

Technical description
TOC Link Physical specifications TOC Link Operating environment TOC Link Limitations
TOC Link Hardware requirements TOC Link Software requirements


Physical specifications

                                  Width     Depth      Height     Weight
                                  -----     -----      ------     ------
Model 520
 
  Rack-mounted drawer             437mm     508mm      178mm      43kg
                                (17.2in)    (20in)      (7in)    (95lb)
  Stand-alone server               201mm    584mm      533mm      43kg
                                 (7.9in)    (23in)     (21in)    (95lb)
 
Expansion Towers
 
  #0588 PCI-X Expansion Unit      485mm    1075mm      200mm      68kg
  in Rack                       (19.1in)  (42.3in)    (8.0in)   (150lb)
  #0595 PCI-X Tower Unit          366mm     728mm      610mm    52.7kg
  in Rack                       (14.5in)  (28.7in)   (24.0in)   (116lb)
  #5088 PCI-X Expansion           485mm    1075mm      200mm      68kg
                                (19.1in)  (42.3in)    (8.0in)   (150lb)
  #5094 PCI I/O Enclosure         485mm    1075mm      910mm     280kg
                                (19.1in)  (42.3in)   (35.8in)   (617lb)
  #5095 PCI-X Expansion           366mm     728mm      610mm    52.7kg
                                (14.5in)  (28.7in)   (24.0in)   (116lb)
 #5294 PCI 1.8m I/O Tower         216mm    1020mm     1800mm     726kg
                                 (8.5in)  (40.1in)   (71.0in)  (1600lb)
 

Operating environment

Model 520

  • Electrical:
    • kVA (maximum): 0.632
    • Rated voltage and frequency: 100-127/200-240V AC@50/60Hz(+/-.5)
    • Power consumption (maximum): 750 Watts
    • Thermal output (maximum): 2046 BTU/hr

  • Noise level (dBa):
    • Rack drawer: 6.0 bels (operating)
    • Deskside: 6.8 bels (operating)

  • Inrush and leakage: 88A

  • Current (mA/A): 85/1.15

  • Temperature: 5 to 35 degrees C (41 to 95 degrees F)

  • Relative humidity: 8% to 80%(1)

  • Wet bulb temperature: 23 degrees C (73.4 degrees F)(operating)

Note: (1) All tape media used on the 9405 must have a relative humidity range of 20% to 80%.

Voltage

Model 520 and expansion units/towers #0595 and #5095 operate at low- voltage (100-127 VAC) or high-voltage (200-240 VAC). Expansion units/towers #0588, #5088, #5094, and #5294 operate at high-voltage only.

The appropriate system power cord is added automatically by the configurator based on the country in which the order is placed. For default power cord, other power cord options, and additional technical planning information, refer to the iSeries planning Web site at:

http://www.ibm.com/eserver/iseries/infocenter

  1. Select Language
  2. V5R4
  3. Site Map
  4. Then Planning

Limitations

Not applicable.

Hardware requirements

Not applicable.

Software requirements

IBM System i5 servers and features require i5/OS V5R3, or later, and some may require updates.

For prerequisite information, visit:

http://www-912.ibm.com/e_dir/eServerPrereq.nsf

Back to topBack to top
 
Publications

There are no publications for this offering.
Back to topBack to top
 

Features
TOC Link Features - No charge TOC Link Features - Chargeable TOC Link Feature descriptions
TOC Link Feature Conversions TOC Link Feature exchanges


Features - No charge

None.

Features - Chargeable

Feature availability matrix

Order codes:

  • I - Available on initial orders from the plant only
  • M - Available on field upgrade (MES) orders only
  • B - Available on both initial and field upgrade orders
  • S - Supported for migration only and cannot be ordered

As additional features are announced, supported, or withdrawn, this list will be updated. Contact your IBM representative for additional information.

        |5|
        |2|
        |0|
Feature | |        Description
--------|-|-----------------------------------------
0005    |M| Bulk Order Indicator
0006    |I| LPAR Restrict Build Process
0032    |S| Modem
0040    |B| Mirrored System Disk Level
0041    |B| Device Parity Protection-All
0042    |M| Mirrored System IOP Level
0043    |M| Mirrored System Bus Level
0047    |M| Device Parity RAID-6 All
0092    |S| External xSeries Attach
0140    |B| Logical Partitioning Specify
0141    |S| HSL OptiConnect Specify
0142    |B| Linux Partition Specify
0145    |B| AIX Partition Specify
0162    |B| Extended Single Ended Attach
0163    |B| Fibre Channel Attach
0165    |B| VHDCI Attachment
0205    |S| RISC-to-RISC Data Migration
0223    |S| 100Mbps Token-Ring Specify
0226    |B| 1Gbps Ethernet Specify
0272    |I| Renovated by IBM
0275    |B| CSC Specify
0276    |S| CSC Specify
0277    |S| CSC Specify
0278    |S| CSC Specify
0279    |S| CSC Specify
0280    |S| CSC Specify
0281    |S| CSC Specify
0282    |S| CSC Specify
0283    |S| CSC Specify
0284    |S| CSC Specify
0290    |S| Ext Device Attach Via #5736
0296    |M| Custom Data Protection
0299    |S| MES Conversion Analysis
0300    |M| EXP24 Attach via #5736/#5775
0301    |M| EXP24 Attach via #5737/#5776
0302    |M| EXP24 Attach via Existing
0308    |M| Mirrored System-IOA Level
0310    |M| EXP24 Attach via #5739/#5778
0325    |S| IPCS Extension Cables for NT
0347    |M| RAID Hot Spare Specify
0348    |B| V.24/EIA232 20-Ft PCI Cable
0353    |B| V.35 20-Ft PCI Cable
0356    |S| V.36 20-Ft PCI Cable
0359    |B| X.21 20-Ft PCI Cable
0367    |B| Operations Console PCI Cable
0371    |B| LC-SC Adapter Kit (50um)
0372    |B| LC-SC Adapter Kit (62.5um)
0446    |S| 512MB DDR Server Memory
0447    |S| 1GB DDR Server Memory
0473    |B| Project Identify Code
0474    |B| SAP Express A1 specify
0496    |S| Force i5/OS Preload
0530    |S| Software Version V5R3
0531    |S| V5R3 OS, V5R3M5 Machine Code
0532    |B| V5R4 OS, V5R4M0 Machine Code
0533    |B| V5R4OS, V5R4M5 Machine Code
0534    |S| i5/OS V6R1 M0 Machine Code
0551    |B| iSeries Rack
0553    |B| iSeries 2.0m Rack
0554    |S| iSeries 11U Rack
0555    |M| iSeries 25U Rack
0566    |A| IBM i 6.1 with 6.1.1 Machine Code Specify Code
0567    |A| IBM i 7.1 Specify Code
0588    |S| PCI-X Expansion Unit in Rack
0595    |S| PCI-X Tower Unit in Rack
0599    |B| Rack Filler Panel Kit
0600    |B| CCEP
0603    |S| Direct Attach-2744
0609    |S| Direct Attach-2772
0613    |B| Direct Attach-2742
0614    |S| Direct Attach-2793
0616    |S| Direct Attach-2805
0620    |S| Direct Attach-5700
0621    |S| Direct Attach-5701
0623    |S| Direct Attach-2849
0625    |S| Direct Attach-5704
0626    |S| Direct Attach-2787
0627    |S| Direct Attach-2780
0628    |S| Direct Attach-5703
0629    |S| 4Gbps Fibre Channel (1-Port)
0630    |M| PCI-X 1Gbps iSCSI TOE-Copper
0631    |S| PCI-X 1Gbps iSCSI TOE-Optic
0632    |S| PCI USB 2.0 Adapter
0633    |S| Graphics Adapter
0634    |S| 128-port ASYNC Adapter
0635    |S| SDLC/X.25 - 2-port Adapter
0641    |S| PCI-X Ultra320 SCSI Disk Ctl
0645    |S| Direct Attach-5712
0646    |S| Direct Attach-5716
0647    |M| PCI-X Disk/Tape Ctlr No IOP
0648    |S| PCI-X Disk Ctlr-90MB No IOP
0649    |S| Direct Attach-5583
0650    |S| Direct Attach-5778
0651    |S| Direct Attach-5782
0654    |S| Direct Attach-5800
0694    |S| #5094 Equivalent
0696    |S| #5096 Equivalent
0708    |B| Forced #5702/#5712 Placement
0830    |S| #4319 Load Source Specify
0834    |S| #4326/#1266 Load Source Spec
0835    |S| #4327/#1267 Load Source Spec
0836    |S| #4328/#1268 Load Source Spec
0837    |M| SAN Load Source Specify
0841    |M| #4329/#1269 Load Source Spec
0900    |S| 1W Serv Feat 520 1X8950
0901    |S| 1W Serv Feat 520 1X8951
0912    |S| 1W Serv Feat 520 1x8972
0970    |S| 1W Serv Feat 520 1x8325/27
0983    |I| Assembled in USA
1025    |A| Modem Cable - US/Canada
1266    |S| 35.16GB 15k rpm Disk Unit
1267    |S| 70.56GB 15k rpm Disk Unit
1268    |S| 141.12GB 15k rpm Disk Unit
1269    |S| 282.25GB 15k rpm Disk Unit
1292    |S| 300GB 15k rpm Disk Unit
1293    |S| 36.4GB 10k rpm Disk Unit
1294    |S| 73.4GB 10k rpm Disk Unit
1295    |S| 146.8GB 10k rpm Disk Unit
1296    |S| 36.4GB 15k rpm Disk Unit
1297    |S| 73.4GB 15k rpm Disk Unit
1298    |S| 146.8GB 15k rpm Disk Unit
1299    |S| 300GB 10k rpm Disk Unit
1307    |S| 1.75m HSL-2 Cable
1308    |S| 2.5m HSL-2 Cable
1311    |M| System Unique Identifier
1406    |S| 200V 16A 14-Ft TL Line Cord
1410    |S| 200V 6-Ft Line Cord
1411    |S| 200V 14-Ft Line Cord
1412    |S| 125V 6-Ft Line Cord
1414    |S| 200V 6-Ft Locking Line Cord
1415    |S| 200V 6-Ft Wtrtght Line Cord
1422    |S| 3m IEC 320 C13/14 PDU Cord
1426    |S| 200V 14-Ft Locking Line Cord
1427    |S| 200V 14-Ft Wtrtght Line Cord
1451    |S| 200V 6-Ft Line Cord
1452    |S| 200V 14-Ft Line Cord
1453    |S| 200V 6-Ft Locking Line Cord
1454    |S| 200V 12A 14-Ft TL Line Cord
1455    |S| 200V 6-Ft Wtrtght Line Cord
1456    |S| 200V 14-Ft Wtrtght Line Cord
1457    |S| 200V 6-Ft Upper Line Cord
1458    |S| 200V 6-Ft Upper Locking Cord
1459    |S| 200V 6-Ft Upper Wtrtght Cord
1460    |S| 3m Copper HSL Cable
1461    |S| 6m Copper HSL Cable
1462    |S| 15m Copper HSL Cable
1474    |S| 6m HSL to HSL-2 Cable
1475    |S| 10m HSL to HSL-2 Cable
1481    |S| 1.2m HSL-2 Cable
1482    |S| 3.5m HSL-2 Cable
1483    |S| 10m HSL-2 Cable
1485    |S| 15m HSL-2 Cable
1487    |S| 3m HSL to HSL-2 Cable
1700    |S| IPCS Keyboard/Mouse for NT
1827    |B| Serial-UPS Conversion Cable
1850    |S| VHDCI to P Converter Cable
1851    |S| 0.6m SCSI P-P Cable
1852    |S| 2.5m SCSI P-P Cable
1855    |S| 4-port EIA 232 Cable
1860    |S| ASYNC Terminal/Prt Cable
1870    |S| USB Keyboard-Dutch
1871    |S| USB Keybd-Bulgarian
1872    |S| USB Keyboard-Portuguese
1873    |B| Dwr to Dwr Serial Cable
1874    |B| Rack to Rack Serial Cable
1875    |B| Serial Port Converter Cable
1876    |S| L200P Flat Panel Monitor
1889    |S| 80GB VXA-2 Tape Drive
1893    |S| 36.4GB 10k rpm Disk Unit
1894    |S| 73.4GB 10k rpm Disk Unit
1895    |S| 146.8GB 10k rpm Disk Unit
1896    |S| 36.4GB 15k rpm Disk Unit
1897    |S| 73.4GB 15k rpm Disk Unit
1898    |S| 146.8GB Disk Unit
2114    |S| Ext Diff SCSI y-Cable
2124    |S| 1m SCSI Cable
2125    |S| 3m SCSI Cable
2126    |S| 5m SCSI Cable
2127    |S| 10m SCSI Cable
2128    |S| 20m SCSI Cable
2138    |S| 0.55m SCSI Cable
2591    |B| Ext 1.44GB Diskette Drive
2640    |B| DVD-ROM
2742    |B| PCI Two-Line WAN IOA
2744    |S| PCI 100Mbps Token-Ring IOA
2749    |S| PCI Ultra Mag Media Ctlr
2757    |S| PCI-X Ultra RAID Disk Ctrl
2772    |S| PCI Dual WAN/Modem IOA
2780    |S| PCI-X Ultra4 RAID Disk Ctrl
2787    |S| PCI-X Fibre Chan Disk Ctlr
2793    |S| PCI 2-Line WAN w/Modem
2805    |S| PCI Quad Modem IOA
2844    |S| PCI IOP
2847    |S| PCI IOP for SAN Load Source
2849    |S| PCI 100/10Mbps Ethernet IOA
2863    |S| 4-Port X.21 Cable
2864    |S| 4-Port V.35 DTE Cable
2877    |S| 4-Position Int Bus Cable
2888    |S| HSL-2/RIO-G Ports - 2 Copper
2917    |B| English U/L DBCS
2924    |B| English
2934    |B| ASYNC Terminal/Prt Cable
2936    |B| ASYNC Modem Cable
2943    |S| 8-Port ASYNC Adapter
2947    |S| PCI Multiprotocol Adapter
2951    |S| V.24/EIA 232 Cable
2952    |S| V.35 Cable
2953    |S| V.36 Cable
2954    |S| X.21 Cable
2958    |B| Universal Japanese
3578    |S| 300GB 10K rpm Disk Unit
3585    |M| 300GB 15k rpm Disk Unit
3637    |S| T541H/L150P TFT Color Monito
3638    |S| C220P 21" Color Monitor
3639    |S| L180P TFT 17" Color Display
3640    |S| L171P TFT 17" Black Display
3641    |S| T115 TFT 15" Color Display
3643    |S| T120 TFT 20" Color Display
3644    |S| T119 TFT 19" Color Display
3645    |S| T117 TFT 17" Color Display
3658    |S| 428.43GB 15k rpm SAS Disk Dr
3677    |S| 139.5GB 15k rpm SAS Disk Drv
3678    |S| 283.7GB 15k rpm SAS Disk Drv
3691    |M| SAS Cbl (YO) 1X Adp-Enc 1.5M
3692    |M| SAS Cable (YO) 1X Adp-Enc 3M
3693    |M| SAS Cable (YO) 1X Adp-Enc 6M
3694    |M| SAS Cable (YO) 1X Adp-Enc 15M
4242    |B| 6-Ft Ext Cable for Display
4256    |B| Extender Cable for Keybd
4263    |S| Direct Attach Tape Cables
4270    |S| Ctlr to External Port Cable
4319    |S| 35.16GB 10k rpm Disk Unit
4326    |S| 35.16GB 15k rpm Disk Unit
4327    |S| 70.56GB 15k rpm Disk Unit
4328    |S| 141.12GB 15k rpm Disk Unit
4329    |M| 282.25GB 15k rpm Disk Unit
4353    |S| 8-Position H.100 Bus Cable
4400    |S| 1GB DDR2 Main Storage
4443    |S| 512MB DDR-1 Main Storage
4444    |S| 1GB DDR-1 Main Storage
4445    |S| 4GB DDR-1 Main Storage
4447    |S| 2GB DDR-1 Main Storage
4449    |S| 8GB DDR-1 Main Storage
4450    |S| 16GB DDR-1 Main Storage
4474    |S| 2GB DDR2 Main Storage
4475    |S| 4GB DDR2 Main Storage
4477    |S| 8GB DDR2 Main Storage
4631    |S| DVD-ROM
4633    |S| DVD-RAM
4684    |S| 30GB 1/4-Inch Cartridge Tape
4685    |S| 80GB VXA-2 Tape Drive
4687    |S| 50GB 1/4-Inch Cartridge Tape
4688    |S| 160GB VXA-320 Tape Drive
4690    |S| Rack Status Beacon Assembly
4691    |S| Rack Status Beacon Cable
4692    |S| Junction Box Cable
4693    |S| Rack Beacon Junct Box Cable
4746    |S| PCI Twinaxial Workstn IOA
4801    |S| PCI Crypto Coprocessor
4805    |S| PCI Crypto Accelerator
4806    |S| PCI-X Crypto Coprocessor
4810    |S| PCI Integ xSeries Server
4811    |S| PCI Integ xSeries Server
4812    |S| PCI Integ xSeries Server
4813    |S| PCI Integ xSeries Server
4959    |S| PCI 16/4Mbps Token-Ring IOA
4962    |S| PCI 100/10Mbps Ethernet IOA
5000    |I| Software Preload Required
5001    |S| Customer Solution Center
5002    |I| AS/400 CDSC - Rochester Mfg
5088    |S| PCI-X Expansion Unit
5094    |M| PCI-X Expansion Tower
5095    |S| PCI-X Expansion Tower
5096    |M| PCI-X Exp Tower (no disk)
5108    |S| 30-Disk Expansion Feature
5115    |S| Dual Line Cords - Tower
5116    |B| Dual Line Cords - 5294 Tower
5138    |S| Redundant Power and Cooling
5158    |S| 850W AC Power Supply
5159    |S| 850 Watt Power Supply
5160    |S| Power Dist Unit 1 Phase NEMA
5294    |B| 1.8m I/O Tower
5296    |M| 1.8m I/O Tower (no disk)
5540    |B| Sys Console on Twinax WSC
5544    |B| Sys Console on OP Console
5546    |S| Sys Console 100Mbps Tkn-Rng
5548    |S| Sys Console 100Mbps Ethernet
5550    |B| Sys Console On HMC
5552    |S| Sys Console on Thin Console
5553    |B| Sys Console-Ethernet No IOP
5554    |S| Mirror 35GB Disk/Ctlr Pkg
5555    |S| Mirror 70GB Disk/Ctlr Pkg
5556    |S| Mirror 141GB Disk/Ctlr Pkg
5557    |S| Sys Console-Ethernet No IOP
5560    |S| Mirror 35GB Drawer Package
5561    |S| Mirror 70GB Drawer Package
5562    |S| Mirror 35GB Tower Package
5563    |S| Mirror 70GB Tower Package
5570    |S| 5727 Cache + 2 70GB Disk Pkg
5571    |S| 5727 Cache + 6 70GB Disk Pkg
5580    |S| 2780 Ctlr w/Aux Write Cache
5581    |S| 2757 Ctlr w/Aux Write Cache
5582    |S| 5738 Ctlr w/Aux Write Cache
5583    |S| 5777 Ctlr w/Aux Write Cache
5590    |S| 2780 Ctlr w/Aux Write Cache
5591    |S| 2757 Ctlr w/Aux Write Cache
5647    |M| PCIe Blind Swap Cassette Std
5700    |B| PCI 1Gbps Ethernet IOA
5701    |B| PCI 1Gbps Ethernet UTP IOA
5703    |S| PCI-X RAID Disk Unit Ctlr
5704    |S| PCI-X Fibre Chan Tape Ctlr
5706    |B| PCI-X 1Gbps Ethernet-TX IOA
5707    |B| PCI-X 1Gbps Ethernet-SX IOA
5709    |S| RAID Enabler Card
5712    |S| PCI-X Tape Controller
5713    |S| PCI-X 1Gbps iSCSI TOE-Copper
5714    |S| PCI-X 1Gbps iSCSI TOE-Optic
5715    |S| PCI-X Tape/DASD Controller
5718    |S| 10Gbps Ethernet IOA (Short)
5719    |S| 10Gbps Ethernet IOA (Long)
5721    |S| PCI-X 10Gbps Ethernet-SR IOA
5722    |S| PCI-X 10Gbps Ethernet-LR IOA
5723    |S| 2-Port Async EIA-232 PCI IOA
5727    |S| Integrated Cache - 40MB
5736    |S| PCI-X Disk/Tape Ctlr w/IOP
5737    |S| PCI-X Disk Ctlr-90MB w/IOP
5738    |S| PCI-X Disk Ctlr-1.5GB w/IOP
5739    |S| PCI-X EXP24 Ctlr-1.5GB w/IOP
5740    |S| 1Gbps BaseT Ethernet(4-Port)
5741    |S| EXP24 6 Disk Slot Enabler
5742    |S| EXP24 6/12 Disk Slot Enabler
5749    |M| 4Gbps Fibre Channel (2-Port)
5751    |B| DVD-RAM
5753    |S| 30GB 1/4-Inch Cartridge Tape
5754    |S| 50GB 1/4-Inch Cartridge Tape
5755    |S| 200GB LTO-2 Tape Unit
5758    |S| 4Gbps Fibre Channel (1-Port)
5759    |S| 4Gbps Fibre Channel (2-Port)
5760    |S| PCI-X Fibre Chan Disk Ctlr
5761    |S| PCI-X Fibre Chan Tape Ctlr
5775    |M| PCI-X Disk/Tape Ctlr-No IOP
5776    |S| PCI-X Disk Ctlr-90MB No IOP
5777    |S| PCI-X Disk Ctlr-1.5GB No IOP
5778    |S| PCI-X EXP24 Ctl-1.5GB No IOP
5781    |S| PCI-X EXP24 Ctlr-1.5GB w/IOP
5782    |S| PCI-X EXP24 Ctl-1.5GB No IOP
5783    |M| PCI-X iSCSI HBA Copper
5784    |S| PCI-X iSCSI HBA Fiber
5786    |S| TotalStorage EXP24 Disk Dwr
5787    |S| TotalStorage EXP24 Disk Twr
5790    |S| PCI Expansion Drawer
5799    |S| PCI-X EXP24 Ctlr-1.5GB w/IOP
5800    |S| PCI-X EXP24 Ctl-1.5GB No IOP
5886    |S| EXP 12S SAS Disk Drawer
5904    |S| PCI-X DDR 1.5GB Cache SAS RAID Adapter
5908    |S| PCI-X DDR 1.5GB Cache SAS RAID Adapter (BSC)
5951    |S| USB Keyboard-US English
5952    |S| USB Keyboard-French
5953    |S| USB Keyboard-Italian
5954    |S| USB Keyboard-German/Austrian
5955    |S| USB Keyboard-UK English
5956    |S| USB Keyboard-Spanish
5957    |S| USB Keybd-Japanese
5958    |S| USB Keybd-Brazil/Portuguese
5959    |S| USB Keybd-Hungarian
5960    |S| USB Keybd-Korean
5961    |S| USB Keybd-Chinese/US
5962    |S| USB Keybd-French/Canadian
5963    |S| USB Keyboard-Canadian/French
5964    |S| USB Keyboard-Belgium/UK
5965    |S| USB Keyboard-Swedish/Finnish
5966    |S| USB Keyboard-Danish
5967    |S| USB Keybd-Bulgarian
5968    |S| USB Keyboard-Swiss/Fr/German
5969    |S| USB Keyboard-Norwegian
5970    |S| USB Keyboard-Dutch
5971    |S| USB Keyboard-Portuguese
5972    |S| USB Keybd-Greek
5973    |S| USB Keybd-Hebrew
5974    |S| USB Keybd-Polish
5975    |S| USB Keybd-Slovakian
5976    |S| USB Keybd-Czech
5977    |S| USB Keybd-Turkish
5978    |S| USB Keyboard-LA Spanish
5979    |S| USB Keybd-Arabic
5980    |S| USB Keybd-Thailand
5981    |S| USB Keybd-Russian
5982    |S| USB Keybd-Russian
5983    |S| USB Keybd-US English Euro
6001    |S| SPCN Power Cable - 2m
6006    |B| SPCN Power Cable - 3m
6007    |B| SPCN Power Cable - 15m
6008    |S| SPCN Power Cable - 6m
6029    |S| SPCN Power Cable - 30m
6068    |B| Opt Front Door for 1.8m Rack
6069    |B| Opt Front Door for 2.0m Rack
6134    |S| 60GB 8mm Tape Unit
6204    |S| Differential SCSI Adapter
6246    |S| 1.8m Rack Trim Kit
6247    |S| 2.0m Rack Trim Kit
6248    |B| 1.8m Rack Acoustic Doors
6249    |B| 2.0m Rack Acoustic Doors
6258    |B| 36GB 4mm Tape Unit
6263    |A| 1.8m Rack Trim Kit
6272    |A| 2.0m Rack Trim Kit
6279    |S| 160GB VXA-320 Tape Drive
6312    |S| Quad Digital Trunk Adapter
6417    |M| HSL-2/RIO-G Bus Adapter
6455    |S| 14-Ft 250V/10A Power Cord
6458    |B| 14-Ft Int 250V/10A Pwr Cd
6459    |S| 12-Ft 250V/10A RA Pwr Cd
6460    |B| 14-Ft 125V/15A Power Cord
6469    |B| 14-Ft 250V/15A Power Cord
6470    |B| 6-Ft 125V/15A Power Cord
6487    |S| 6-Ft 250V/15A Power Cord
6492    |B| 14-Ft 1PH/48-60A Pwr Cord
6497    |B| 6-Ft 250V/15A Power Cord
6498    |S| 6-Ft 250V/15A Power Cord
6574    |S| 4-Disk Slot Exp - Base Ctlr
6580    |B| Optional Rack Security Kit
6585    |S| DASD Locking Kit
6586    |M| Modem Tray for 19-Inch Rack
6587    |S| Rear Cover
6594    |S| 4-Disk Slot Exp-PCI-X Ctlr
6598    |B| Disk Slot Filler (Qty 4)
6654    |B| 14-Ft 1PH/24-30A Pwr Cord
6655    |B| 14-Ft 1PH/24-30A WR Pwr Cord
6664    |S| 7-Ft 200V PDU Power Cable
6671    |M| 9Ft IEC 320 C13/14 PDU Cord
6672    |M| 5Ft IEC 320 C13/14 PDU Cord
6800    |S| PCI 1Gbps Ethernet IOA
6801    |S| PCI 1Gbps Ethernet UTP IOA
6803    |S| PCI WAN for ECS
6805    |M| PCI 2-Line WAN IOA No IOP
6808    |S| PCI 4-Modem WAN IOA No IOP
6833    |M| PCI 2-Line WAN w/Modem NoIOP
7109    |M| Intelligent PDU Plus
7140    |S| 520 Express Configuration
7141    |S| 520 Express Configuration
7142    |S| 520 Express Configuration
7143    |S| 520 Express Configuration
7144    |S| 520 Express Configuration
7148    |S| 520 Express Configuration
7152    |S| 520 Express Configuration
7180    |S| Acoustic Front Door
7181    |S| Easy-Access Front Cover
7182    |S| Rack Mount
7188    |B| Power Distribution Unit
7198    |S| Adjustable Depth Rack Rails
7307    |S| Dual I/O Unit Enclosure
7311    |S| Dual I/O Unit Enclosure
7354    |S| Accelerator for System i5
7390    |S| Model 520 Express Edition
7391    |S| Model 520 Express Edition
7392    |S| Model 520 Express Edition
7393    |S| Model 520 Express Edition
7394    |S| Model 520 Express Edition
7395    |S| Model 520 Express Edition
7396    |S| Model 520 Express Edition
7504    |S| Quantity 150 of #4319
7508    |S| Quantity 150 of #4326
7509    |S| Quantity 150 of #4327
7510    |S| Quantity 150 of #4328
7511    |M| Quantity 150 of #4329
7516    |S| Quantity 150 of #1269
7518    |S| Quantity 150 of #3677
7519    |S| Quantity 150 of #3678
7520    |S| Quantity 150 of #1266
7521    |S| Quantity 150 of #1267
7522    |S| Quantity 150 of #1268
7526    |S| Quantity 150 of #1295
7527    |S| Quantity 150 of #1296
7528    |S| Quantity 150 of #1297
7529    |S| Quantity 150 of #1298
7538    |S| Quantity 150 of #3658
7680    |S| Accelerator for System i5
7681    |S| Accelerator for System i5
7682    |S| Accelerator for System i5
7687    |S| Accelerator for System i5
7750    |S| Easy-Access Front Cover
7753    |S| Acoustic Front Door
7780    |S| 2.0m Rack Side Attach Kit
7801    |S| 6m HMC Attachment Cable
7802    |B| 15m HMC Attachment Cable
7840    |B| Side-by-Side for 1.8m Racks
7841    |B| Ruggedize Rack Kit
7862    |S| Blind Swap Cassette (Long)
7863    |M| Blind Swap Cassette (Double)
7883    |S| Model 520 OEM Rack Mount
7884    |S| 520 Rack Mount
7885    |S| Deskside
7940    |B| Adv Power Virtualization
8131    |S| 15-Ft Cluster Box Cable
8132    |S| 9-Inch Cluster Box Cable
8133    |S| RJ45 to DB25 Interposer
8136    |S| Remote ASYNC Node (Rack)
8137    |S| Remote ASYNC Node
8244    |S| PCI WS Audio Adapter
8325    |S| 520 1.9GHz Processor
8327    |S| 1.9GHz Processor
8546    |S| Opt Base 1GB Server Memory
8800    |S| USB Keyboard-US English
8801    |S| USB Keyboard-French
8802    |S| USB Keyboard-Italian
8803    |S| USB Keyboard-German/Austrian
8804    |S| USB Keyboard-UK English
8805    |S| USB Keyboard-Spanish
8806    |S| USB Keybd-Japanese
8807    |S| USB Keybd-Brazil/Portuguese
8808    |S| USB Keyboard-Canadian/French
8810    |S| USB Keyboard-Belgium/Dutch
8811    |S| USB Keyboard-Swedish/Finnish
8812    |S| USB Keyboard-Danish
8814    |S| USB Keyboard-Swiss/Fr/German
8816    |S| USB Keyboard-Norwegian
8819    |S| USB Keybd-Greek
8820    |S| USB Keybd-Hebrew
8821    |S| USB Keybd-Hungarian
8823    |S| USB Keybd-Polish
8825    |S| USB Keybd-Slovakian
8826    |S| USB Keybd-Czech
8827    |S| USB Keybd-Turkish
8829    |S| USB Keyboard-LA Spanish
8830    |S| USB Keybd-Arabic
8833    |S| USB Keybd-Korean
8834    |S| USB Keybd-Chinese/US
8835    |S| USB Keybd-French/Canadian
8836    |S| USB Keybd-Thailand
8838    |S| USB Keybd-Russian
8839    |S| USB Keybd-Yugoslavian/Latin
8840    |S| USB Keybd-US English
8841    |S| USB Mouse and Keybd Cable
8950    |S| 520 1.5GHz Processor
8951    |S| 520 1.5GHz Processor
8972    |S| 520 1.5GHz Processor
9004    |B| Southern Hemisphere Display
9493    |S| Base PCI WAN for ECS
9509    |S| Base Ultra320 SCSI RAID Cntr
9510    |S| Base Integrated Cache - 40MB
9517    |S| Base HSL-2/RIO-G Bus Adapter
9526    |S| Base 35.16GB 15k rpm Disk Dr
9531    |S| Base HSL-2 Bus Adapter
9540    |S| Base DVD-ROM
9544    |S| Base 1GB Main Storage
9545    |S| Base 4GB DDR-1 Main Storage
9547    |S| Base 2GB Main Storage
9548    |S| Base 1GB Main Storage
9549    |S| Base 2GB Main Storage
9553    |S| Base 4GB Main Storage
9613    |S| Base 70GB 15k rpm Disk Unit
9653    |S| Base 30GB 1/4-Inch Cart Tape
9726    |S| Base 512MB Server Memory
9744    |S| Base PCI IOP
9746    |S| Base PCI Twinax Wrkstn IOA
9793    |S| Base PCI 2-Line WAN w/Modem
9844    |S| Base PCI IOP
9877    |S| Base HSL-2 Bus Adapter
9933    |S| PCI 2-Line WAN w/Modem NoIOP
 

Special Features - Plant and/or Field Installable

  • Rack Related
    • (#6263) -1.8m Rack Trim Kit
    • (#6272) -2.0m Rack Trim Kit
  • Specify Codes
    • (#0567) -IBM i 7.1 Specify Code

Feature descriptions

Following are the descriptions, in numeric order, for all features on this model.

Attributes, as defined in the descriptions, state the interaction of requirements among features.

Minimums and maximums are the absolute limits for a single feature without regard to interaction with other features. The maximum valid quantity for MES orders may be different than for initial orders. The maximums listed below refer to the largest quantity of these two possibilities.

The order type defines if a feature is orderable only on initial orders, only on MES orders, on both initial and MES orders, or if a feature is supported on a model as a result of a model conversion.

(#0005) - Bulk Order Indicator

This specify code is used by manufacturing applications to determine the correct number of additional hardware items (i.e., wrist straps) to include on a bulk MES order.

  • For 9405-520: (#0005)
    • Minimum required: 0
    • Maximum allowed: 1PO (Initial order maximum: 0)
    • OS level required: i5/OS V4R5, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#0006) - LPAR Restrict Build Process

Added to an initial order system when multiple i5/OS partitions (#0140) are requested. This code instructs manufacturing to only load SLIC on the minimum number of DASD files (i.e., do not spread across all available DASD units). Mutually exclusive with #5000 SW Preload and with #0205 - RISC-to-RISC Data Migration.

  • For 9405-520: (#0006)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V4R4, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A

(#0032) - Modem

(No Longer Available as of July 29, 2011)

This specify is required if an external high speed modem is to be shipped with the system. The exact machine type-model of the modem shipped will vary based on what is currently stocked in manufacturing.

  • For 9405-520: (#0032)
    • Minimum required: 0
    • Maximum allowed: 192 (Initial order maximum: 192)
    • OS level required: i5/OS V2R1, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0040) - Mirrored System Disk Level

This code indicates the level of disk protection desired and helps ensure that adequate hardware is in the final configuration.

For new systems: Causes the marketing configurator to error if sufficient disk units are not ordered to support device-level mirrored protection. #0040 causes all disk units to be placed into configurations capable of implementing mirrored pairs.

For upgrade orders: #0040 will cause the marketing configurator to error if sufficient disk units are not available to provide mirroring capability.

It is the customer's responsibility to start mirroring on their system.

Mirrored system disk level protection requires all disk units to be placed into mirrored pairs and mirroring be started. The load source must be controlled by the first disk controller on the first system bus and must be mirrored to a like disk unit also attached to the first disk controller on the first system bus.

The minimum number of disks allowed on a system is two.

  • Attributes provided: Device-level mirrored protection
  • Attributes required: Minumum of two (2) disk units
  • For 9405-520: (#0040)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V2R1, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0041) - Device Parity Protection-All

This code indicates the level of disk protection desired and helps ensure that adequate hardware is in the final configuration.

This is the default specify code for data protection capability.

For new systems: Causes the marketing configurator to error if a disk unit or adapter is ordered that is not capable of implementing RAID protection. #0041 causes all internal disk units to be placed into configurations capable of implementing RAID arrays using a RAID-capable disk controller.

For upgrade orders: #0041 will cause the order to replace adapters that are not RAID-capable with RAID-capable adapters. The marketing configurator will error if there are not enough disk units to support a minimum RAID configuration.

It is the customer's responsibility to start RAID on their system.

Device parity protection requires all disk units to be placed in sets large enough to turn on RAID protection, as well as be connected to a RAID-capable adapter. The rules for RAID can be found in the disk controller descriptions.

  • Attributes provided: RAID Data Protection
  • Attributes required: RAID-capable disk unit controller
  • For 9405-520: (#0041)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V4R5, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0042) - Mirrored System IOP Level

This code indicates the level of disk protection desired and helps ensure that adequate hardware is in the final configuration.

For new systems: The marketing configurator will error if sufficient disk units and IOPs are not included on the order to support IOP-level mirrored protection. #0042 causes all disk units to be placed into configurations capable of IOP-level mirroring. Each disk unit and its mirrored pair must be on a different disk unit IOP.

Important: The load source disk unit in a new, preloaded system will be device-level mirrored (same protection as provided in #0040, above). This means that the load source is controlled by the first disk unit controller on the first system bus, and will be mirrored with a like disk unit that is also attached to the same first disk controller on the first system bus.

For upgrade orders: #0042 will cause the marketing configurator to error if sufficient disk units, adapters, and IOPs are not available to provide the capability to enable IOP-level mirrored protection for all DASD.

It is the customer's responsibility to start mirroring on their system.

The minimum number of disks allowed on a system is four.

  • Attributes provided: IOP-level mirrored protection
  • Attributes required: Minimum of 4 (four) disk units
  • For 9405-520: (#0042)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: i5/OS V4R1, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#0043) - Mirrored System Bus Level

This code indicates the level of disk protection wanted and helps ensure that adequate hardware is in the final configuration.

For new systems: The marketing configurator will error on an order if sufficient disk units, IOPs, and expansion units are not included on the order to support bus-level mirrored protection for all disk units. New, preloaded systems will be shipped with bus- level mirroring enabled.

Important: The load source disk unit in a new, preloaded system will be device-level mirrored. This means that the load source is controlled by the first disk controller on the first system bus and will be mirrored with a like disk unit that is also attached to the same first disk controller on the first system bus. Bus level mirroring of the Load Source disk unit can be achieved only by enabling Remote Load Source Mirroring before starting Mirrored Protection. Details about implementing Remote Load Source Mirroring can be found in the iSeries Information Center. Visit:

http://publib.boulder.ibm.com/iseries/

For upgrade orders: The marketing configurator will error if sufficient disk units, IOPs, and expansion units are not available to provide the capability to enable bus-level mirrored protection for all disk units.

It is the client's responsibility to start mirroring on their system.

Bus-level mirroring requires all disk units to be placed into mirrored pairs on separate busses. Refer to the iSeries Information Center for important Mirrored Protection and Remote Load Source Mirroring implementation details.

LPAR systems require additional planning.

The minimum number of disks allowed on a system is four.

  • Attributes provided: Bus-level mirrored protection
  • Attributes required: Minimum of 4 (four) disk units
  • For 9405-520: (#0043)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: i5/OS V3R1, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#0047) - Device Parity RAID-6 All

This code indicates the level of disk protection desired and helps ensure that adequate hardware is in the final configuration.

For new systems: Causes the order to fail if a disk unit or adapter is ordered that is not capable of implementing RAID-6 protection. #0047 causes all internal disk units to be placed into configurations capable of implementing RAID-6 arrays using a RAID-6 capable disk controller. RAID-6 arrays require a minimum of four disk units per array (all disk units within an array must be of the exact same capacity).

For upgrade orders: #0047 will cause the order to replace adapters that are not RAID-6 capable with RAID-6 capable adapters. A warning message will be generated during RAID enablement if there are not enough disk units to support a minimum RAID configuration.

It is the customer's responsibility to start RAID on their system.

Device parity protection requires all disk units to be placed in sets large enough to turn on RAID protection, as well as be connected to a RAID-capable adapter. The rules for RAID can be found in the disk controller descriptions.

  • Attributes provided: RAID-6 Data Protection
  • Attributes required: RAID-6 capable disk unit controller
  • For 9405-520: (#0047)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#0092) - External xSeries Attach

(No Longer Available as of October 29, 2010)

#0092 is added to an order for each Direct Attached xSeries Server connected to the system. The marketing configurators use this code to determine the number of HSL and SPCN cables required and to insure that the number of External xSeries Servers does not exceed the system limit. Each External xSeries Server is cabled with a pair of HSL cables and attached to the SPCN string like all other HSL attached I/O towers.

  • For 9405-520: (#0092)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 8)
    • OS level required: i5/OS V5R1, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0140) - Logical Partitioning Specify

#0140 is used to specify that this system will be logically partitioned. A quantity of one #0140 is required on the order/system for each logical partition running i5/OS.

Initial system orders and model upgrade orders containing this specify will ship without RAID or mirroring enabled.

  • For 9405-520: (#0140)
    • Minimum required: 0
    • Maximum allowed: 10 (Initial order maximum: 10)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0141) - HSL OptiConnect Specify

(No Longer Available as of October 29, 2010)

#0141 specifies that this system will be part of a cluster using HSL OptiConnect.

This code allows additional HSL cables to be ordered for clustered systems.

  • For 9405-520: (#0141)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0142) - Linux Partition Specify

#0142 is used to specify that this system will be logically partitioned with a Linux partition. A quantity of one #0142 needs to be on the order/system for each Linux partition required.

Direct-attach features are not allowed in OS/400 partitions.

There are no minimum number of Linux direct-attached features required per Linux partition. A Linux partition can exist without any direct- attach features in it. In this case, the system will provide virtual I/O for those Linux partitions that contain no direct-attach features.

  • Attributes provided: One Linux Partition
  • Attributes required: #0140 Logical Partitioning Specify
  • For 9405-520: (#0142)
    • Minimum required: 0
    • Maximum allowed: 9 (Initial order maximum: 9)
    • OS level required: Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0145) - AIX Partition Specify

#0145 is used to specify that this system will be logically partitioned with an AIX partition. A quantity of one #0145 needs to on the order/inventory records for each AIX partition required.

AIX offered/supported features are allowed only within an AIX partition. AIX offered/supported features are not allowed in i5/OS partitions.

There are no minimum number of AIX direct-attached features required per AIX partition. An AIX partition can exist without any AIX features in it. In this case, the system will provide virtual I/ O for those AIX partitions that contain no AIX features.

  • Attributes provided: AIX Secondary Partition
  • Attributes required: Logical Partitioning Specify (#0140)
  • For 9405-520: (#0145)
    • Minimum required: 0
    • Maximum allowed: 9 (Initial order maximum: 9)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0162) - Extended Single Ended Attach

#0162 is added to an order for each of the following devices directly attaching (not second on a daisy-chained string) to a system via a #5702/#5712/#5715 controller.

  • 7329-308 - 1/4-Inch Tape Autoloader
  • 7210-025 - DVD-RAM Drive

Note: If any of the above devices will be daisy-chained off of another device, then the #0162 specify is not to be added to the order.

  • Attributes provided: Indicates External SCSI device attachment
  • Attributes required: #5702, #5712 or #5715
  • For 9405-520: (#0162)
    • Minimum required: 0
    • Maximum allowed: 36 (Initial order maximum: 36)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

    Single partition systems and individual partitions are limited to a max of 18 #0162s.

(#0163) - Fibre Channel Attach

This specify is added to an order for each device attaching to an iSeries system via a #2765 PCI Fibre Channel Tape Controller or #5704 PCI-X Fibre Channel Tape Controller.

  • Attributes provided: Indicates External Fibre Channel device attachment
  • Attributes required: #2765
  • For 9405-520: (#0163)
    • Minimum required: 0
    • Maximum allowed: 36 (Initial order maximum: 36)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

    Single partition maximum is 18.

(#0165) - VHDCI Attachment

#0165 is used to indicate that an external CD/DVD/tape device will be attached to a #5702, #5712 or #5715 controller.

  • Attributes provided: Indicates VHDCI SCSI device attachment
  • Attributes required: #5702, #5712 or #5715
  • For 9405-520: (#0165)
    • Minimum required: 0
    • Maximum allowed: 36 (Initial order maximum: 36)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

    Single partition maximum is 18.

(#0205) - RISC-to-RISC Data Migration

Used on initial orders to designate that the new server will replace (not upgrade) a server on which i5/OS or OS/400 is installed.

When #0205 is on the order, manufacturing will only load SLIC and up through QSYS of i5/OS. This will facilitate migrating some of the i5/OS information from the installed system. In addition to the new server, enough DASD must be ordered to hold all the data from the current model, as well as the required software on the new server.

Specify code #5000, SW Preload Required, is mutually exclusive with #0205.

The migration process requires that the installed model be at the same version and release level of OS/400 and other licensed programs as the new server. Financial considerations of upgrades to the installed software should be reviewed as part of the migration planning.

  • For 9405-520: (#0205)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A

(#0223) - 100Mbps Token-Ring Specify

(No longer available as of July 01, 2008)

Indicates that a #2744 100/16/4Mbps Token-Ring adapter is being used on an integrated xSeries server. For each #2744 used on/with an integrated server, one #0223 is required on the order or system inventory records.

  • For 9405-520: (#0223)
    • Minimum required: 0
    • Maximum allowed: 36 (Initial order maximum: 36)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#0226) - 1Gbps Ethernet Specify

Indicates that a #5700/#5701 1Gbps Ethernet adapter is being used on an integrated xSeries server. One #0226 is required for each #5700 or #5701 used.

  • Attributes provided: #5700 or #5701 installed on Integrated xSeries Server
  • Attributes required: Integrated xSeries Server and (#5700 or #5701)
  • For 9405-520: (#0226)
    • Minimum required: 0
    • Maximum allowed: 36 (Initial order maximum: 36)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0272) - Renovated by IBM

Renovated by IBM is a specify code used to indicate that the system/MES will be built from new or refurbished parts.

  • For 9405-520: (#0272)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A

(#0275) - CSC Specify

For exclusive use by the Rochester Custom Solution Center. Marketing configurator support is not required/provided. Having #0275 on the order, will cause the order content to be internally routed to the CSC build area in building 114 (Rochester).

  • Attributes provided: Order content routing to CSC build area in building 114.
  • Attributes required: None
  • For 9405-520: (#0275)
    • Minimum required: 0
    • Maximum allowed: 1PO (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0276) - CSC Specify

(No Longer Available as of February 9, 2010)

For exclusive use by the Rochester Custom Solution Center. Marketing configurator support is not required/provided.

  • For 9405-520: (#0276)
    • Minimum required: 0
    • Maximum allowed: 1PO (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0277) - CSC Specify

(No Longer Available as of February 9, 2010)

For exclusive use by the Rochester Custom Solution Center. Marketing configurator support is not required/provided.

  • For 9405-520: (#0277)
    • Minimum required: 0
    • Maximum allowed: 1PO (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0278) - CSC Specify

(No Longer Available as of February 9, 2010)

For exclusive use by the Rochester Custom Solution Center. Marketing configurator support is not required/provided.

  • For 9405-520: (#0278)
    • Minimum required: 0
    • Maximum allowed: 1PO (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0279) - CSC Specify

(No Longer Available as of February 9, 2010)

For exclusive use by the Rochester Custom Solution Center. Marketing configurator support is not required/provided.

  • For 9405-520: (#0279)
    • Minimum required: 0
    • Maximum allowed: 1PO (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0280) - CSC Specify

(No Longer Available as of February 9, 2010)

For exclusive use by the Rochester Custom Solution Center. Marketing configurator support is not required/provided.

  • For 9405-520: (#0280)
    • Minimum required: 0
    • Maximum allowed: 1PO (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0281) - CSC Specify

(No Longer Available as of February 9, 2010)

For exclusive use by the Rochester Custom Solution Center. Marketing configurator support is not required/provided.

  • For 9405-520: (#0281)
    • Minimum required: 0
    • Maximum allowed: 1PO (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0282) - CSC Specify

(No Longer Available as of February 9, 2010)

For exclusive use by the Rochester Custom Solution Center. Marketing configurator support is not required/provided.

  • For 9405-520: (#0282)
    • Minimum required: 0
    • Maximum allowed: 1PO (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0283) - CSC Specify

(No longer available as of April 15, 2005)

For exclusive use by the Rochester Custom Solution Center. Marketing configurator support is not required/provided.

  • For 9405-520: (#0283)
    • Minimum required: 0
    • Maximum allowed: 1PO (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0284) - CSC Specify

(No longer available as of April 15, 2005)

For exclusive use by the Rochester Custom Solution Center. Marketing configurator support is not required/provided.

  • For 9405-520: (#0284)
    • Minimum required: 0
    • Maximum allowed: 1PO (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0290) - Ext Device Attach Via #5736

(No Longer Available as of May 27, 2011)

Each #0290 is used to indicate one external port of a #5736 or #5775 will be used to control an external tape device.

Note: #5736 and #5775 are physically the same adapter card, but have different feature numbers to indicate to IBM configuration tools that an IOP is or is not being used in the configuration.

  • Attributes provided: Placement code for IBM Configurator Tools
  • Attributes required: #5736 PCI-X Disk/Tape Controller with IOP or #5775 PCI-X Disk/Tape Controller - no IOP
  • For 9405-520: (#0290)
    • Minimum required: 0
    • Maximum allowed: 36 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#0296) - Custom Data Protection

#0296 specifies that a system has multiple i5/OS partitions and that data protection schemes should be considered separately for each partition instead of only for an overall system level. Each partition's data protection scheme can be different or the same.

  • For 9405-520: (#0296)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#0299) - MES Conversion Analysis

(No longer available as of January 31, 2008)

This specify will temporarily hold an order in IBM manufacturing. It is used when an already installed #2780 or #2757 is being converted to a #5580 or #5581. It allows time for an automated tool to analyze the existing customer configuration and identify if special I/O configuration planning is required.

  • For 9405-520: (#0299)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 0)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#0300) - EXP24 Attach via #5736/#5775

#0300 is used to indicate that the external port of a #5736/#5775 will be connected to one 6-pack of disk slots on a #5786/#5787 TotalStorage EXP24 Disk Drawer/Tower. A #5736/#5775 connected to a #5786/#5787 is not capable of attaching/driving any additional internal disk units.

  • Attributes provided: None
  • Attributes required: At a minimum, the existence of one #5736/#5775 per each #0300.
  • For 9405-520: (#0300)
    • Minimum required: 0
    • Maximum allowed: 47 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#0301) - EXP24 Attach via #5737/#5776

#0301 is used to indicate that one external port of a #5737/#5776 will be connected to one or two 6-packs of disk slots on a #5786/ #5787 TotalStorage EXP24 Disk Drawer/Tower.

Both external ports of a #5737/#5776 can be connected to #5786s/ #5787s. Both ports of a #5737/#5776 can connect to the same #5786/ #5787 or to different 5786s/#5787s. With both ports connected to #5786s/#5787s, a #5737/#5776 is not capable of attaching/driving any additional internal disk units and/or internal tape/optical devices.

  • Attributes provided: None
  • Attributes required: At a minimum, the existence of one #5737/#5776 per pair of #0301s.
  • For 9405-520: (#0301)
    • Minimum required: 0
    • Maximum allowed: 47 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#0302) - EXP24 Attach via Existing

This specify code is used to help IBM configuration tools. It is used on an EXP24 Disk Enclosure MES order to indicate that an already installed disk controller will be used to control an EXP24 6 pack or 12 pack of disk drives. Fewer disk controllers or disk controller ports are therefore required on the EXP24 MES order. The marketing configurator will determine the quantity (if any) of #0302 on a given EXP24 Disk Encloslure MES order.

  • Attributes provided: None
  • Attributes required: Existing SCSI disk controller port being used to connect to an EXP24 enclosure
  • For 9405-520: (#0302)
    • Minimum required: 0
    • Maximum allowed: 47 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#0308) - Mirrored System-IOA Level

This specify code indicates the level of disk protection desired and helps ensure that adequate hardware is in the final configuration.

For new systems, the marketing configurator will show an error if sufficient disk units and disk controllers are not included on the order to support IOA-level mirroring protection. #0308 causes all disk units to be placed into configurations capable of IOA-level mirroring. Each disk unit and its mirrored pair must be on a different disk controller.

Note that the load source disk unit in a new, preloaded system will be device-level mirrored (same protection as provided with feature #0040). This means that the load source is controlled by the first disk unit controller on the first system bus, and will be mirrored with a like disk unit that is also attached to the same first disk controller on the first system bus.

For upgrade orders, #0308 will cause the marketing configurator to show an error if sufficient disk units and disk controllers are not available to provide the capability to enable IOA-level mirrored protection for all DASD.

It is the client's responsibility to start mirroring on their system.

  • Attributes provided: IOA level system mirroring
  • Attributes required: A minimum of two disk controllers and a even number of disk units (with a minimum of four disk units on a system).
  • For 9405-520: (#0308)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#0310) - EXP24 Attach via #5739/#5778

#0310 is used to indicate that one port of a #5739/#5778/#5781/ #5782/#5799/#5800 will be connected to one or two 6-packs of disk slots of a #5786/#5787 TotalStorage EXP24 Disk Drawer/Tower.

All three external ports of a #5739/#5778/#5781/#5782/#5799/#5800 can be connected to #5786s/#5787s. All three ports of a #5739/#5778/ #5781/#5782/#5799/#5800 can connect to the same #5786/#5787 or to different 5786s/#5787s.

  • Attributes provided: None
  • Attributes required: At a minimum, the existence of one #5739/#5778/#5781/#5782/#5799/ #5800 per each trio of #0310s.
  • For 9405-520: (#0310)
    • Minimum required: 0
    • Maximum allowed: 47 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#0325) - IPCS Extension Cables for NT

(No longer available as of May 08, 2007)

This feature provides extension cables for the display, mouse and keyboard that are required when running an IXS with the NT operating system. This feature should be used when longer cables are required to attach the display, mouse, and keyboard to the IXS.

Note that the keyboard cable supplied with this feature is for a standard keyboard connection, not a USB attached keyboard.

  • Attributes provided: Connectivity for keyboard, display and mouse
  • Attributes required: Integrated xSeries Server with NT Operating System, keyboard, display and mouse.
  • For 9405-520: (#0325)
    • Minimum required: 0
    • Maximum allowed: 18 (Initial order maximum: 18)
    • OS level required: i5/OS V4R2, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#0347) - RAID Hot Spare Specify

#0347 is a specify code that indicates to IBM configuration tools and to IBM Manufacturing that RAID-5 or RAID-6 disk arrays should be further protected using the i5/OS function of RAID hot spare. If specified, IBM will ship a configuration which has at least one stand-by disk drive for each disk controller in the system or designated partition. The customer may alter the hot spare configuration selecting different options once the system is installed.

  • Attributes provided: N/A
  • Attributes required: Existence of #0041 or #0047
  • For 9405-520: (#0347)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: i5/OS V5R4, with V5R4M5 Machine Code, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#0348) - V.24/EIA232 20-Ft PCI Cable

This feature provides a 20-foot WAN PCI cable that supports a V.24 or a EIA232 electrical connection interface.

  • For 9405-520: (#0348)
    • Minimum required: 0
    • Maximum allowed: 192 (Initial order maximum: 192)
    • OS level required: i5/OS V3R7, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0353) - V.35 20-Ft PCI Cable

This feature provides a 20-foot WAN PCI cable that supports a V.35 electrical connection interface.

  • For 9405-520: (#0353)
    • Minimum required: 0
    • Maximum allowed: 192 (Initial order maximum: 192)
    • OS level required: i5/OS V3R7, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0356) - V.36 20-Ft PCI Cable

(No longer available as of January 31, 2008)

This feature provides a 20-foot WAN PCI cable that supports a V.36 electrical connection interface.

  • For 9405-520: (#0356)
    • Minimum required: 0
    • Maximum allowed: 192 (Initial order maximum: 192)
    • OS level required: i5/OS V3R7, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#0359) - X.21 20-Ft PCI Cable

This feature provides a 20-foot WAN PCI cable that supports a X.21 electrical connection interface.

  • For 9405-520: (#0359)
    • Minimum required: 0
    • Maximum allowed: 192 (Initial order maximum: 192)
    • OS level required: i5/OS V3R7, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0367) - Operations Console PCI Cable

A #0367 requires one RVX port (communications port, not modem port). A customer can select a #0367 for each i5/OS partition. There is a max of one #0367 per card. If a card has two RVX ports, a #0367 can connect to one port and the other port can be used for other comm support.Features supporting the #0367 cable are #2742, #2793, #2794, #4745, #6807, #6833, #6834, #9771, #9793, #9794, #9933 and #9934. If a system has #5544, then at a minimum, one #0367 is required.

This feature ships a PCI card compatible Operations Console cable. This cable ships with a 25 pin to 9 pin adapter.

  • For 9405-520: (#0367)
    • Minimum required: 0
    • Maximum allowed: 10 (Initial order maximum: 10)
    • OS level required: i5/OS V4R3, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0371) - LC-SC Adapter Kit (50um)

50 micron fiber LC-SC conversion kit.

  • For 9405-520: (#0371)
    • Minimum required: 0
    • Maximum allowed: 37 (Initial order maximum: 37)
    • OS level required: i5/OS V5R1, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0372) - LC-SC Adapter Kit (62.5um)

62.5 micron fiber LC-SC conversion kit.

  • For 9405-520: (#0372)
    • Minimum required: 0
    • Maximum allowed: 37 (Initial order maximum: 37)
    • OS level required: i5/OS V5R1, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0446) - 512MB DDR Server Memory

(No longer available as of July 08, 2008)

512 MB DDR memory for an Integrated xSeries Server.

#0446 must be installed in pairs.

  • Attributes provided: 512MB memory for Integrated xSeries Server
  • Attributes required: One memory slot on Integrated xSeries Server
  • For 9405-520: (#0446)
    • Minimum required: 0
    • Maximum allowed: 72 (Initial order maximum: 72)
    • OS level required: i5/OS V5R2, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

    This feature is ordered for IXS in towers/cages that are designated as Customer Set Up and for IXS in towers/cages that are designated as "Install By IBM."

(#0447) - 1GB DDR Server Memory

(No longer available as of July 08, 2008)

1 GB DDR memory for an Integrated xSeries Server.

#0447 must be installed in pairs.

  • Attributes provided: 1GB memory for Integrated xSeries Server
  • Attributes required: One memory slot on Integrated xSeries Server
  • For 9405-520: (#0447)
    • Minimum required: 0
    • Maximum allowed: 72 (Initial order maximum: 72)
    • OS level required: i5/OS V5R2, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

    This feature is ordered for IXS in towers/cages that are designated as Customer Set Up and for IXS in towers/cages that are designated as "Install By IBM".

(#0473) - Project Identify Code

PowerNet code added to orders driven from PowerNet activities to help track the orders.

  • For 9405-520: (#0473)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0474) - SAP Express A1 specify

  • For 9405-520: (#0474)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0496) - Force i5/OS Preload

(No longer available as of July 24, 2007)

Preloads i5/OS on a new server, even though partitioning has been specified. #0496 forces the preload of a single i5/OS partition when Linux or AIX 5L partitions with virtual storage have been configured. This feature will result in i5/OS being preloaded on all the disk drives in the ordered configuration. Do not use this feature if the Linux or AIX 5L partition has dedicated disk controllers and drives included in the ordered configuration.

#0496 is mutually exclusive with #0006.

  • Attributes provided: i5/OS Preload
  • Attributes required: iSeries Server
  • For 9405-520: (#0496)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A

(#0530) - Software Version V5R3

(No Longer Available as of November 27, 2009)

This specify code is used to indicate what release of OS/400 will be used on the system. For an LPAR system, this specify indicates what release of OS/400 will be used in the system's primary partition.

  • For 9405-520: (#0530)
    • Minimum required: 0
    • Maximum allowed: 1PO (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

    #0530 does not support processors #8325 or #8327

(#0531) - V5R3 OS, V5R3M5 Machine Code

(No Longer Available as of November 27, 2009)

Indicates the level of machine code used on an i5/OS V5R3 system. Machine code is sometimes referred to as Licensed Internal Code or LIC. For an LPAR system, this specify indicates the level of machine code used in the system's primary partition.

V5R3M5 Machine Code requires a minimum i5/OS load source size of 17 GB.

  • Attributes required: i5/OS V5R3
  • For 9405-520: (#0531)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0532) - V5R4 OS, V5R4M0 Machine Code

This specify code is used to indicate what release of i5/OS will be used on the system. For an LPAR system, this specify indicates what release of i5/OS will be used in the system's primary partition. V5R4 i5/OS with V5R4M0 machine code requires a minimum i5/ OS load source size of 17GB.

  • For 9405-520: (#0532)
    • Minimum required: 0
    • Maximum allowed: 1PO (Initial order maximum: 1)
    • OS level required: i5/OS V5R4, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0533) - V5R4OS, V5R4M5 Machine Code

This specify code is used to indicate what release of i5/OS will be used on the system. For an LPAR system, this specify indicates what release of i5/OS will be used in the system's primary partition. V5R4 i5/OS with V5R4M5 machine code requires a minumum i5/ OS load source size of 17GB.

  • Attributes provided: V5R4OS, V5R4M5 Machine Code
  • For 9405-520: (#0533)
    • Minimum required: 0
    • Maximum allowed: 1PO (Initial order maximum: 1)
    • OS level required: i5/OS V5R4 with V5R4M5 Machine Code, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0534) - i5/OS V6R1 M0 Machine Code

(No Longer Available as of August 31, 2012)

This specify code is used to indicate what release of i5/OS will be used on the system. For an LPAR system, this specify indicates what release of i5/OS will be used in the system's primary partition. V6R1 i5/OS requires a minimum i5/OS load source size of 17GB.

  • Attributes provided: V6R1OS
  • For 9405-520: (#0534)
    • Minimum required: 0
    • Maximum allowed: 1PO (Initial order maximum: 1)
    • OS level required: i5/OS V6R1
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0551) - 19 inch 1.8 Meter Rack

Provides a 19 inch, 1.8 meter high rack with 36 EIA units of total space for installing rack mounted CECs and/or expansion units. One of the following features are required on the #0551:

  • #6068 - Optional Front Door for 1.8m Rack
  • #6246 - 1.8m Rack Trim Kit
  • #6248 - 1.8m Rack Acoustic Doors

The following features are also orderable on the #0551:

  • #0599 - Rack Filler Panel Kit
  • #6580 - Optional Rack Security Kit
  • #7840 - Side-By-Side for 1.8m Racks
  • #7841 - Ruggedize Rack Kit

The #0551 can support up to eight PDUs, four mounted vertically and four mounted horizontally. Each PDU mounted horizontally takes up 1 EIA of rack space. The following PDUs are supported:

  • #5160 - Power Distribution Unit 1 Phase NEMA (6 sockets) (supported, not orderable)
  • #5161 - Power Distribution Unit 1 Phase IEC (6 sockets) (supported, not orderable)
  • #5162 - Power Distribution Unit 2 of 3 Phase (6 sockets) (supported, not orderable)
  • #5163 - Power Distribution Unit - 3 Phase (6 sockets) (supported, not orderable)
  • #7188 - Power Distribution Unit (12 sockets)
  • #7109 - Power Distribution Unit (12 sockets)

All racked units plugging into a PDU will require a PDU line cord with a C14 plug.

  • Attributes provided: 19 inch, 1.8M, 36 EIA Rack
  • Attributes required: #6068 or #6246 or #6248.
  • For 9405-520: (#0551)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0553) - 19 inch 2.0 Meter Rack

Provides a 19-inch, 2.0 meter high rack with 42 EIA units of total space for installing rack mounted CECs and/or expansion units. One of the following features are required on the #0553:

  • #6069 - Optional Front Door for 2.0m Rack
  • #6247 - 2.0m Rack Trim Kit
  • #6249 - 2.0m Rack Acoustic Doors

The following features are also orderable on the #0553:

  • #0599 - Rack Filler Panel Kit
  • #6580 - Optional Rack Security Kit
  • #7780 - 2.0m Rack Side Attach Kit
  • #7841 - Ruggedize Rack Kit

The #0553 can support up to nine power distribution units (PDU), four mounted vertically and five mounted horizontally. Each PDU mounted horizontally takes up 1 EIA of rack space. The following PDUs are supported:

  • #5160 - Power Distribution Unit 1 Phase NEMA (6 sockets) (support only. not orderable)
  • #5161 - Power Distribution Unit 1 Phase IEC (6 sockets) (support only. not orderable)
  • #5162 - Power Distribution Unit 2 of 3 Phase (6 sockets) (support only. not orderable)
  • #5163 - Power Distribution Unit 3 Phase (6 sockets) (support only. not orderable)
  • #7188 - Power Distribution Unit (12 sockets)
  • #7109 - Power Distribution Unit (12 sockets)

All racked units plugging into a PDU will require a PDU line cord with a C14 plug.

  • Attributes provided: 19 inch, 2.0M, 42 EIA Rack
  • Attributes required: #6069 or #6247 or #6249
  • For 9405-520: (#0553)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0554) - 19 inch 0.6 Meter Rack

(No longer available as of April 01, 2008)

Provides a 19-inch, .6 meter (24-inch) high rack with 11 EIA units of total space for installing rack mounted CECs and/or expansion units. The #0554 includes a lockable front door. Filler panels and a perforated front door are included to help provide proper airflow and cooling. A rear door is not offered.

The following feature is orderable on the #0554:

  • #0599 - Rack Filler Panel Kit (if extra filler panels are required)

The #0554 supports up to six PDUs that are mounted horizontally. Each PDU takes up one EIA of rack space. The following PDUs are supported:

  • #5160 - Power Distribution Unit 1 Phase NEMA (6 sockets) (supported, not orderable)
  • #5161 - Power Distribution Unit 1 Phase IEC (6 sockets) (supported, not orderable)
  • #5162 - Power Distribution Unit 2 of 3 Phase (6 sockets) (supported, not orderable)
  • #5163 - Power Distribution Unit - 3 Phase (6 sockets) (supported, not orderable)
  • #7188 - Power Distribution Unit (12 sockets) (orderable)

All racked units plugging into a PDU will require a PDU line cord with a C14 plug.

  • Attributes provided: 19 inch, .6M, 11 EIA Rack
  • Attributes required: None
  • For 9405-520: (#0554)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: 0)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#0555) - 19 inch 1.3 Meter Rack

Provides a 19-inch, 1.3 meter (49-inch) high rack with 25 EIA units of total space for installing rack-mounted CECs and/or expansion units. The #0555 includes lockable front and rear doors. Filler panels and perforated doors are included to help provide proper airflow and cooling.

The following feature is orderable on the #0555:

  • #0599 - Rack Filler Panel Kit (if extra filler panels are required)

The #0555 supports up to 12 PDUs that are mounted horizontally. Each PDU takes up one EIA of rack space. The following PDUs are supported:

  • #5160 - Power Distribution Unit 1 Phase NEMA (6 sockets) (supported, not orderable)
  • #5161 - Power Distribution Unit 1 Phase IEC (6 sockets) (supported, not orderable)
  • #5162 - Power Distribution Unit 2 of 3 Phase (6 sockets) (supported, not orderable)
  • #5163 - Power Distribution Unit - 3 Phase (6 sockets) (supported, not orderable)
  • #7188 - Power Distribution Unit (12 sockets) (orderable)
  • #7109 - Power Distribution Unit (12 sockets)

All racked units plugging into a PDU will require a PDU line cord with a C14 plug.

  • Attributes provided: 19 inch, 1.3M, 25 EIA Rack
  • Attributes required: None
  • For 9405-520: (#0555)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: 0)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#0566) - IBM i 6.1 with 6.1.1 Machine Code Specify Code

This feature is used to indicate the correct level of code when IBM i is specified.

  • Attributes provided: IBM i 6.1 with 6.1.1 Machine Code Indicator
  • Attributes required: IBM i operating system
  • For 9405-520: (#0566)
    • Minimum required: 0
    • Maximum allowed: 1PO (Initial order maximum: 1)
    • OS level required: IBM i 6.1.1
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes
    • Return parts MES: No

(#0567) - IBM i 7.1 Specify Code

This feature is used to indicate the correct level of code when IBM i is specified.

  • Attributes provided: IBM i 7.1 indicator
  • Attributes required: IBM i operating system
  • For 9405-520: (#0567)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 0)
    • OS level required: IBM i 7.1.0
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes
    • Return parts MES: No

(#0588) - PCI-X Expansion Unit in Rack

(No longer available as of June 01, 2006)

#0588 is the equivalent of a #5088 PCI-X Expansion Unit, but the #0588 is a rack mounted unit. An #0588 is eight EIA units high and has 14 PCI-X slots for PCI IOPs and IOAs. Disk units and removable media are not supported in the #0588. The #0588 cannot be converted to a #5088. A #5088 cannot be converted to a #0588.

PCI IOAs are supported by feature #2843/#2844 PCI IOPs, feature #2790, #2890 PCI Integrated Netfinity Servers and feature #2791, #2792, #2799, #2891, #2892, #2899, and #4810 PCI Integrated xSeries Servers. A #9844/#9943 may be used in a #0588.

The #0588 has two redundant 575W power supplies and two integrated PDU compatible line cords. Both line cords may be connected to the same PDU or to separate PDUs in a rack. When the line cords are connected to separate PDUs, and those PDUs are connected to two different power sources, the #0588 has dual line cord capability.

A bus adapter to provide the HSL interface to the system is included. Select one of the following:

  • #9877 - Base HSL-2 Bus Adapter, to specify two copper HSL-2 ports
  • #9876 - Base Optical Bus Adapter, to specify two optical HSL ports

One or two cables must be ordered to attach to the HSL or HSL-2 ports.

When ordering cables to connect to the HSL interface, optical HSL, copper HSL, copper HSL-2, or copper HSL to HSL-2 cables are required. An HSL loop uses all optical or all copper ports/cables. A copper loop can intermix I/O towers/units with copper HSL and copper HSL-2 ports. Select the appropriate cable based on the type of HSL ports to which it is being attached and desired cable length.

  • Copper HSL to HSL-2 (HSL on one end and HSL-2 on the other end)
    • #1474 - 6m HSL to HSL-2 Cable
    • #1475 - 10m HSL to HSL-2 Cable
  • Copper HSL-2 (HSL-2 on both ends of the cable)
    • #1482 - 3.5m HSL-2 Cable
    • #1483 - 10m HSL-2 Cable
    • #1485 - 15m HSL-2 Cable
    • #1470 - 6m HSL Optical Cable (model 570 only)
    • #1471 - 30m HSL Optical Cable (model 570 only)
    • #1472 - 100m HSL Optical Cable (model 570 only)
    • #1473 - 250m HSL Optical Cable (model 570 only)

For each I/O tower/unit select one of the following SPCN cables:

  • #1463 - 2m SPCN Cable
  • #1464 - 6m SPCN Cable
  • #1465 - 15m SPCN Cable
  • #1466 - 30m SPCN Cable
  • #0369 - 100m Optical SPCN Cable (model 570 only)
  • #1468 - 250m Optical SPCN Cable (model 570 only)
  • #6001 - 2m SPCN Cable
  • #6006 - 3m SPCN Cable
  • #6007 - 15m SPCN Cable
  • #6008 - 6m SPCN Cable
  • #6029 - 30m SPCN Cable
  • Attributes provided: 14 PCI-X slots
  • Attributes required: HSL/HSL-2 cables, SPCN cables
  • For 9405-520: (#0588)
    • Minimum required: 0
    • Maximum allowed: 6 (Initial order maximum: 6)
    • OS level required: i5/OS V5R2, or later Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#0595) - PCI-X Tower Unit in Rack

Feature #0595 is the racked version of the #5095 PCI-X Expansion Tower that provides expanded I/O capability for iSeries systems. The #0595 has identical functional capabilities to the #5095. The #0595 has seven PCI-X IOP/IOA slots and supports up to 12 disk units. #0595 uses five EIA units of space in a rack.

A #9844 Base PCI IOP is included with each #0595.

Note: With the availability of V5R4, #9844 is not longer included with #0595.

A bus adapter to provide the HSL interface to the system is required. Select one of the following:

  • #9517 - Base HSL-2 Bus Adapter, to specify two copper HSL-2 ports
  • #9876 - Base Optical Bus Adapter, to specify two optical HSL ports

    Note: If ordered for a 9408-M25 or 9409-M50 a #6699 (RIO-2 Bus Adapter) must be ordered instead of a #9517 or #9876.

One or two HSL cables must be ordered with each #0595.

When ordering cables to connect to the HSL interface, optical HSL, copper HSL, copper HSL-2, or copper HSL to HSL-2 cables are required. An HSL loop uses all optical or all copper ports/cables. A copper loop can intermix I/O towers/units with copper HSL and copper HSL-2 ports. Select the appropriate cable based on the type of HSL ports to which it is being attached, and the cable length required.

The following HSL cables can be used with a #0595:

  • Copper HSL to HSL-2 (HSL on one end and HSL-2 on the other end)
    • #1474 - 6m HSL to HSL-2 Cable
    • #1475 - 10m HSL to HSL-2 Cable
    • #1487 - 3m HSL to HSL-2 Cable
  • Copper HSL-2 (HSL-2 on both ends of the cable)
    • #1307 - 1.75m HSL-2 Cable
    • #1308 - 2.5m HSL-2 Cable
    • #1481 - 1.2m HSL-2 Cable
    • #1482 - 3.5m HSL-2 Cable
    • #1483 - 10m HSL-2 Cable
    • #1485 - 15m HSL-2 Cable
  • Optical HSL (optical HSL connections on both ends of the cable)
    • #1470 - 6m HSL Optical Cable
    • #1471 - 30m HSL Optical Cable
    • #1472 - 100m HSL Optical Cable
    • #1473 - 250m HSL Optical Cable

One SPCN cable is required with each #0595. Select one of the following:

  • #1463 - 2m SPCN Cable
  • #1464 - 6m SPCN Cable
  • #1465 - 15m SPCN Cable
  • #1466 - 30m SPCN Cable
  • #0369 - 100m Optical SPCN Cable
  • #1468 - 250m Optical SPCN Cable
  • #6001 - 2m SPCN Cable
  • #6006 - 3m SPCN Cable
  • #6007 - 15m SPCN Cable
  • #6008 - 6m SPCN Cable
  • #6029 - 30m SPCN Cable

The #0595 has redundant power when feature #5138 is installed. The #5138 provides a second 435W power supply. In addition, when a #5138 is installed, a second line cord must be ordered. The presence of the #5138 and the second line cord, enables dual line cord capability.

Select one of the following line cords, or select two if #5138 is ordered:

  • #1394 - 4.3m 200V/10A Pwr Crd Brazil
  • #1395 - 4.3m 200V/10A Pwr Cd China
  • #1397 - 4.3m 200V/10A Pwr Crd Argent
  • #1398 - 4.3m 100V/10A Pwr Crd Brazil
  • #1410 - 200V 6-Ft Line Cord
  • #1411 - 200V 14-Ft Line Cord
  • #1412 - 125V 6-Ft Line Cord
  • #1413 - 125V 14-Ft Line Cord
  • #1414 - 200V 6-Ft Locking Line Cord
  • #1415 - 200V 6-Ft Watertight Line Cord
  • #1416 - 200V 14-Ft Locking Line Cord
  • #1417 - 200V 14-Ft Wtrtght Line Cord
  • #1422 - 3m IEC 320 C13/14 PDU Cord
  • #1438 - 4.3m 200V/10A Pwr Cd AU/NZ
  • #1439 - 4.3m 200V/10A Pwr Cd EU/Asia
  • #1440 - 4.3m 200V/10A Pwr Cd Denmark
  • #1441 - 4.3m 200V/10A Pwr Cd S Africa
  • #1442 - 4.3m 200V/10A Pwr Cd Swiss
  • #1443 - 4.3m 200V/10A Pwr Cd UK
  • #1444 - 4.3m 200V/10A Pwr Cd Italy
  • #1445 - 4.3m 200V/10A Pwr Cd Israel
  • #6458 - 14-Ft Int 250V/10A Pwr Cd
  • #6460 - 14-Ft 125V/15A Power Cord
  • #6469 - 14-Ft 250V/15A Power Cord
  • #6470 - 6-Ft 125V/15A Power Cord
  • #6471 - 9-Ft 125V/15A Power Cord
  • #6472 - 9-Ft 250V/16A Power Cord
  • #6473 - 9-Ft 250V/10A Power Cord
  • #6474 - 9-Ft 250V/13A Power Cord
  • #6475 - 9-Ft 250V/16A Power Cord
  • #6476 - 9-Ft 250V/10A Power Cord
  • #6477 - 9-Ft 250V/10A Power Cord
  • #6478 - 9-Ft 250V/16A Power Cord
  • #6479 - 9-Ft 250V/10A Power Cord
  • #6487 - 6-Ft 250V/15A Power Cord
  • #6488 - 9-Ft Dual Voltage Pwr Cd
  • #6493 - 9-Ft 250V/10A Power Cord
  • #6494 - 9-Ft 250V/10A Power Cord
  • #6495 - 9-Ft 250V/10A Power Cord
  • #6496 - 9-Ft 250V/10A Power Cord
  • #6497 - 6-Ft 250V/15A Power Cord
  • #6498 - 6-Ft 250V/15A Power Cord
  • #6651 - 9-Ft 127V/15A Power Cord
  • #6659 - 9-Ft 240V/15A Power Cord
  • #6660 - 14-Ft 127V/15A Power Cord
  • #6669 - 14-Ft 240V/15A Power Cord
  • #6670 - 6-Ft 125V/15A Power Cord
  • #6680 - 9-Ft 250V/10A Power Cord
  • #6687 - 6-Ft 250V/15A Power Cord
  • Attributes provided: 7 PCI slots and 12 disk positions
  • Attributes required: HSL cable(s) (either copper or optical)
  • For 9405-520: (#0595)
    • Minimum required: 0
    • Maximum allowed: 6 (Initial order maximum: 6)
    • OS level required: i5/OS V5R2, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#0599) - Rack Filler Panel Kit

Provides rack filler panels for IBM 19-inch racks. The #0599 provides three 1-EIA -unit filler panels and one 3-EIA-unit filler panel. These are snap-on panels.

19-inch racks are shipped from IBM with filler panels for the empty positions. The #0599 provides spare/additional filler panels that may be required due to removal or repositioning of equipment in a rack. Filler panels help maintain proper airflow and cooling within a rack.

  • Attributes provided: Snap on rack filler panels
  • Attributes required: 19-inch rack
  • For 9405-520: (#0599)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: 250)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0600) - CCEP

This process allows the shipping of an order prior to the scheduled ship date. #0600 will alert Rochester manufacturing to ship order prior to scheduled ship date. This is an exception process. Nothing will be announced. #0600 will be added to each order manually.

  • For 9405-520: (#0600)
    • Minimum required: 0
    • Maximum allowed: 1PO (Initial order maximum: 1)
    • OS level required: i5/OS V3R0.5, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0603) - Direct Attach-2744

(No longer available as of June 01, 2006)

#0603 is ordered when the function of a #2744 IOA is required but the card will be controlled by a non-OS/400 operating system.

Cards controlled by a non-OS/400 operating system do not use/ require PCI IOPs. Direct attach cards are supported only in a non-OS/ 400 partition.

Prerequisites:

  • #0140 Logical Partitioning Specify.
  • #0142 Linux Partitioning Specify.
  • Attributes provided: #2744 controlled by Linux operating system
  • Attributes required: #0140, #0142
  • For 9405-520: (#0603)
    • Minimum required: 0
    • Maximum allowed: 34 (Initial order maximum: 34)
    • OS level required: Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#0609) - Direct Attach-2772

(No longer available as of June 01, 2006)

#0609 is ordered when the function of a #2772 IOA is required but the card will be controlled by a non-OS/400 operating system.

Cards controlled by a non-OS/400 operating system do not use/ require PCI IOPs. Direct attach cards are supported only in a non-OS/ 400 partition.

Prerequisites:

  • #0140 Logical Partitioning Specify.
  • #0142 Linux Partitioning Specify.
  • Attributes provided: #2772 controlled by Linux Operating System
  • Attributes required: #0140, #0142
  • For 9405-520: (#0609)
    • Minimum required: 0
    • Maximum allowed: 88 (Initial order maximum: 88)
    • OS level required: Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#0613) - Direct Attach-2742

#0613 is ordered when the function of a #2742 IOA is required but the card will be controlled by a non-i5/OS operating system.

Cards controlled by a non-i5/OS operating system do not use/ require PCI IOPs. Direct attach cards are supported only in a non-i5/ OS partition.

Prerequisites:

  • #0140 Logical Partitioning Specify.
  • #0142 Linux Partitioning Specify.
  • Attributes provided: #2742 controlled by Linux operating system
  • Attributes required: #0140, #0142
  • For 9405-520: (#0613)
    • Minimum required: 0
    • Maximum allowed: 88 (Initial order maximum: 88)
    • OS level required: Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0614) - Direct Attach-2793

#0614 is ordered when the function of a #2793 IOA is required but the card will be controlled by a non-i5/OS operating system.

Cards controlled by a non-i5/OS operating system do not use/ require PCI IOPs. Direct attach cards are supported only in a non-i5/ OS partition.

Prerequisites:

  • #0140 Logical Partitioning Specify.
  • #0142 Linux Partitioning Specify.
  • Attributes provided: #2793 controlled by Linux operating system
  • Attributes required: #0140, #0142
  • For 9405-520: (#0614)
    • Minimum required: 0
    • Maximum allowed: 88 (Initial order maximum: 88)
    • OS level required: Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#0616) - Direct Attach-2805

(No Longer Available as of April 29, 2011)

#0616 is ordered when the function of a #2805 IOA is required but the card will be controlled by a non-i5/OS operating system.

Cards controlled by a non-i5/OS operating system do not use/ require PCI IOPs.

Prerequisites:

  • #0140 Logical Partitioning Specify.
  • #0142 Linux Partitioning Specify.
  • Attributes provided: #2805 controlled by Linux operating system
  • Attributes required: #0140, #0142
  • For 9405-520: (#0616)
    • Minimum required: 0
    • Maximum allowed: 88 (Initial order maximum: 88)
    • OS level required: Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0620) - Direct Attach-5700

#0620 is ordered when the function of a #5700 IOA is required but the card will be controlled by a non-i5/OS operating system.

Cards controlled by a non-i5/OS operating system do not use/ require PCI IOPs. Direct attach cards are supported only in a non-i5/ OS partition.

#0620, #5700 and #6800 are physically the same adapter card but have different feature numbers to indicate to IBM configurator tools that an IOP is or is not being used in the configuration.

Prerequisites:

  • #0140 Logical Partitioning Specify.
  • #0142 Linux Partition Specify or #0145 AIX Partition Specify
  • Attributes provided: #5700 controlled by AIX or Linux operating system
  • Attributes required: #0140 and (#0142 or #0145)
  • For 9405-520: (#0620)
    • Minimum required: 0
    • Maximum allowed: 34 (Initial order maximum: 34)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#0621) - Direct Attach-5701

#0621 is ordered when the function of a #5701 IOA is required but the card will be controlled by a non-i5/OS operating system.

Cards controlled by a non-i5/OS operating system do not use/ require PCI IOPs. Direct attach cards are supported only in a non-i5/ OS partition.

#0621, #5701 and #6801 are physically the same adapter card but have different feature numbers to indicate to IBM configurator tools that an IOP is or is not being used in the configuration.

Prerequisites:

  • #0140 Logical Partitioning Specify.
  • #0142 Linux Partition Specify or #0145 AIX Partition Specify
  • Attributes provided: #5701 controlled by AIX or Linux operating system
  • Attributes required: #0140 and (#0142 or #0145)
  • For 9405-520: (#0621)
    • Minimum required: 0
    • Maximum allowed: 34 (Initial order maximum: 34)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#0623) - Direct Attach-2849

(No longer available as of June 01, 2006)

#0623 is ordered when the function of a #2849 IOA is required but the card will be controlled by a non-OS/400 operating system.

Cards controlled by a non-OS/400 operating system do not use/ require PCI IOPs. Direct attach cards are supported only in a non-OS/ 400 partition.

  • Attributes provided: #2849 controlled by Linux operating system
  • Attributes required: #0140, #0142
  • For 9405-520: (#0623)
    • Minimum required: 0
    • Maximum allowed: 34 (Initial order maximum: 34)
    • OS level required: Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0625) - Direct Attach-5704

(No longer available as of June 01, 2006)

#0625 is ordered when the function of a PCI-X Fibre Chan Tape Ctlr (#5704) is required and the card will be controlled by an AIX or Linux operating system.

Cards controlled by a AIX or Linux operating system do not use/ require PCI IOPs.

Direct attach cards are supported only in an LPAR partition.

  • Attributes provided: Attachment of external tape devices
  • Attributes required: #0140 and (#0142 or #0145)
  • For 9405-520: (#0625)
    • Minimum required: 0
    • Maximum allowed: 36 (Initial order maximum: 0)
    • OS level required: AIX 5L for Power V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#0626) - Direct Attach-2787

(No longer available as of June 01, 2006)

#0626 is ordered when the function of a #2787 IOA is required but the card will be controlled by a non-OS/400 operating system.

Cards controlled by a non-OS/400 operating system do not use/ require PCI IOPs. Direct attach cards are supported only in a non-OS/ 400 partition.

Note: An optics cleaning kit (P/N 46G6844) and instruction sheet (P/ N 21P6238, form number SY27-2604) will be supplied, one per system, when a #0626 or #2787 is ordered.

Prerequisites:

  • #0140 Logical Partitioning Specify.
  • #0142 Linux Partitioning Specify.
  • Attributes provided: #2787 controlled by Linux operating system
  • Attributes required: #0140, #0142
  • For 9405-520: (#0626)
    • Minimum required: 0
    • Maximum allowed: 37 (Initial order maximum: 0)
    • OS level required: Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#0627) - Direct Attach-2780

(No longer available as of May 01, 2008)

#0627 is ordered when the function of a PCI-X Ultra4 RAID Disk Ctlr (#2780)is required and the card will be controlled by a non-i5/ OS operating system.

Cards controlled by non-i5/OS operating systems do not use/ require PCI IOPs.

Direct attach cards are supported only in an LPAR partition.

  • Attributes provided: Support for internal disk drives and internal tape, CD-ROM and DVD units
  • Attributes required: #0140, and #0142 and/or #0145
  • For 9405-520: (#0627)
    • Minimum required: 0
    • Maximum allowed: 24 (Initial order maximum: 24)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

    #0627 (#2780) can not be installed in the model 520 CEC.

(#0628) - Direct Attach-5703

(No longer available as of June 01, 2006)

#0628 is ordered when the function of a #5703 IOA is required but the card will be controlled by a non-OS/400 operating system.

Cards controlled by a non-OS/400 operating system do not use/ require PCI IOPs. Direct attach cards are supported only in a non-OS/ 400 partition.

Prerequisites:

  • #0140 Logical Partitioning Specify.
  • #0142 Linux Partitioning Specify or #0145 AIX Partitioning Specify
  • Attributes provided: #5703 controlled by Linux or AIX Operating System
  • Attributes required: #0140, #0142 or #0145
  • For 9405-520: (#0628)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 8)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

    For Linux or AIX, this adapter is limited to one per secondary partition.

(#0629) - 4Gbps Fibre Channel (1-Port)

(No Longer Available as of January 7, 2011)

Provides a 4Gbps single port fibre channel PCI-X 2.0 adapter, which is a 64-bit address/data, short form factor PCI-X adapter with an LC type external fiber connector. It enables a single initiator over an optical fiber link or loop. With the use of appropriate optical fiber cabling, this adapter enables you to set up a network of high-speed local and remote storage.

This feature is for use only in AIX and Linux partitions. The #0629 will auto-negotiate for the highest data rate between adapter and an attaching device at 1Gbps, 2Gbps or 4Gbps of which the device or switch is capable. Distances of up to 500 meters running at 1Gbps data rate and up to 300 meters running at 2Gbps data rate and 4Gbps data rate up to 150 meters are supported between the adapter and an attaching device or switch. When used with IBM supported fibre channel storage switches supporting long-wave optics, distances of up to 10 kilometers are capable of running at either 1, 2, or 4Gbps data rates.

#0629 can be used to attach devices either directly or by means of fibre channel switches. If attaching a device or switch with an SC type fiber connector, an LC-SC 50 Micron Fiber Converter Cable (#0371) or an LC-SC 62.5 Micron Fiber Converter Cable (#0372) is required.

  • Attributes provided: One-port fibre channel adapter
  • Attributes required: One empty PCI-X slot
  • For 9405-520: (#0629)
    • Minimum required: 0
    • Maximum allowed: 36 (Initial order maximum: 0)
    • OS level required: AIX 5L for Power V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 4, or later, SUSE Linux Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#0630) - PCI-X 1Gbps iSCSI TOE-Copper

Provides a 1Gbps iSCSI TOE PCI-X adapter that encapsulates SCSI commands and data into TCP and transports them over the Ethernet via IP packets. The adapter operates as an iSCSI TCP/IP Offload Engine (TOE). This offload of the host eliminates protocol processing and reduces CPU interrupts. The adapter uses RJ45 1Gbps Ethernet connector. This iSCSI adapter can be used to initiate requests to external storage devices from AIX 5L and Linux partitions.

  • Attributes provided: Offload of host protocol processing
  • Attributes required: Available PCI-X Slot
  • For 9405-520: (#0630)
    • Minimum required: 0
    • Maximum allowed: 15 (Initial order maximum: 0)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, SUSE Linux Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#0631) - PCI-X 1Gbps iSCSI TOE-Optic

(No longer available as of December 02, 2008)

Provides a 1Gbps iSCSI TOE PCI-X adapter that encapsulates SCSI commands and data into TCP and transports them over the Ethernet via IP packets. The adapter operates as an iSCSI TCP/IP Offload Engine (TOE). This offload of the host eliminates protocol processing and reduces CPU interrupts. The adapter uses small form factor LC type fiber optic connector. This iSCSI adapter can be used to initiate requests to external storage devices from AIX 5L and Linux partitions.

  • Attributes provided: Offload of host protocol processing
  • Attributes required: Available PCI-X Slot
  • For 9405-520: (#0631)
    • Minimum required: 0
    • Maximum allowed: 15 (Initial order maximum: 0)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, SUSE Linux Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#0632) - PCI USB 2.0 Adapter

(No Longer Available as of November 27, 2009)

The #0632 is a USB 2.0 capable adapter that provides for the connection of one USB keyboard and mouse. The #0632 is only usable in Linux or AIX partitions.

Limitation: Limited to USB 1.1 support with AIX

  • Attributes provided: USB Keyboard/Mouse Attachment
  • Attributes required: One available PCI slot
  • For 9405-520: (#0632)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 8)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

    This adapter is limited to one per secondary AIX partition.

(#0633) - Graphics Adapter

(No Longer Available as of November 27, 2009)

The #0633 POWER GXT135P Graphics Accelerator with Digital Support is a versatile 2D graphics accelerator which can be configured to operate in either 8-bit or 24-bit color modes. This adapter supports both analog and digital monitors.

  • Hardware description:
    • 128-bit graphics processor
    • 8-bit CLUT or 24-bit true color
    • 16 MB SDRAM
    • 32-bit PCI interface
    • Universal PCI (5.0v or 3.3v)
    • 1 hardware color map
  • Features supported:
    • Up to approximately 16.7 million colors
    • Rectangular clipping
    • 2 analog monitor outputs at up to 1280 x 1024 resolution
    • 1 analog monitor output at up to 2048 x 1536 resolution
    • 1 digital monitor output at up to 1600 x 1200 resolution
    • 60 to 85 Hz refresh rates (ISO 9241, Part 3)
  • APIs supported:
    • X-Windows and Motif
    • UMS 2.3.0 (no hardware scaling)
  • Software requirements: AIX Versions 5.1 or 5.2 (analog or digital support),or later, or AIX 4.3 (analog support only)
  • Attributes provided: 2D Graphics
  • Attributes required: 1 PCI slot
  • For 9405-520: (#0633)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 8)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0634) - 128-port ASYNC Adapter

(No longer available as of December 01, 2005)

The #0634 provides attachment for a high concentration of asynchronous lines (up to 128) from a single PCI bus slot. This gives the system the ability to serve a large number of user of EIA-232 or RS-422 devices such as terminals, printers, and modems.

Two 2.4 Mbps synchronous channels link the adapter to a maximum of eight 16-Port Remote Async Nodes (RANs), up to four RANs can be linked to each synchronous channel.

RANs can also be used with this adapter. If these RANs are connected the synchronous channel the data rate drops down to 1.2 Mbps. For the best results keep the previous and new RAN's on separate synchronous channels.

  • Attributes provided: Up to 128 Async Ports
  • Attributes required: One PCI slot, #0140 (Logical Partitioning Specify and #0145 (AIX Partition Specify)
  • For 9405-520: (#0634)
    • Minimum required: 0
    • Maximum allowed: 10 (Initial order maximum: 10)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#0635) - SDLC/X.25 - 2-port Adapter

(No longer available as of December 01, 2005)

The #0635 SDLC/X.25 - 2-port Adapter provides high-speed connections between stand-alone system units on a WAN. To access WAN lines, the #0635 adapter connects via external communications equipment including Channel Service Units (CSU), Data Service Units (DSU) or through synchronous modems.

This adapter together with IBM AIXlink/X.25 provides a two-port connection to X.25 packet switched networks. IBM AIXlink/X.25 is a separately orderable LPP (5696-926).

The #0635, with an appropriate cable, is compatible with:

  • X.21 DCE - Using 2-Port Cable, X.21 (#2954)
    • CCITT X.21 Signalling
    • CCITT V.11 Electrical
    • CCITT X.27 Electrical
    • EIA-422-A Electrical
    • ISO 4903 Connector for DCE side of an X.21 VHSI Modem Cable
  • V.24 DCE - Using 2-Port Cable, V.24/EIA-232 (#2951)
    • CCITT V.24 Signalling
    • CCITT V.28 Electrical
    • CCITT X.21bis Electrical and Signalling
    • EIA-232-C Electrical and Signalling
    • ISO 2110 Connector for DCE side of an V.24 VHSI Modem Cable
  • V.35 DCE - Using 2-Port Cable, V.35 (#2952)
    • CCITT V.35 Some signals for signalling
    • CCITT V.28 Some signals for electrical and signalling
    • ISO 2593 Connector for DCE side of an V.35 VHSI Modem Cable
  • V.36 DCE - Using 2-Port Cable, V.36/EIA-449 (#2953)
    • CCITT V.10 Electrical
    • CCITT V.11 Electrical
  • Attributes provided: High speed WAN connection
  • Attributes required: One PCI slot, #0140 and #0145
  • For 9405-520: (#0635)
    • Minimum required: 0
    • Maximum allowed: 10 (Initial order maximum: 10)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#0641) - PCI-X Ultra320 SCSI Disk Ctl

(No longer available as of May 01, 2008)

#0641 is ordered when a #5590 is required and will be directly controlled by an AIX operating system. #0641 includes a PCI-X RAID disk controller and an auxiliary write cache IOA each with a maximum compressed write cache of 757MB and a secondary IOA with 1.5GB of auxiliary maximum compressed write cache. The disk controller and the auxiliary IOA each require one PCI-X slot and must be installed together in the same system unit or I/O unit/drawer/tower. The disk controller and the auxiliary write cache IOA are connected by a SCSI cable (provided).

The connecting SCSI cable is attached to port four of the disk controller, reducing the number of SCSI buses that support disk drives from four to three. The reduction of SCSI buses may also reduce the number of disk drives supported by the disk controller, depending on the system unit or I/O unit/drawer/tower in which the disk controller is installed. No disk drives are driven by the auxiliary write cache IOA.

#0641 can support operating system-based or application-based mirroring protection or support controller-based RAID-5. Concurrent battery maintenance is not supported. The controller also supports internal tape units, CD-ROM units, and DVD units. #0641 has four internal u320 SCSI buses.

#5590 and #0641 are physically the same disk controller and auxilary write cache IOA pair of cards, but have different feature numbers to denote to IBM configurator tools whether or not an IOP is required and which operating system is using them. The #0641 indicates no IOP is used and the card is directly controlled by a AIX 5L or Linux partition.

  • Attributes provided: Disk Controller with auxiliary write cache
  • Attributes required: Two PCI-X slots within the same system unit or I/O unit/drawer/tower
  • For 9405-520: (#0641)
    • Minimum required: 0
    • Maximum allowed: 24 (Initial order maximum: 0)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#0645) - Direct Attach-5712

(No longer available as of June 01, 2006)

#0645 is ordered when the function of a #5712 PCI-X Tape Controller is required and the card will be controlled by a non-OS/ 400 operating system. Cards controlled by a non-OS/400 operating system do not use/require PCI IOPs. Direct attach cards are supported only in a non-OS/400 partition.

The #0645 has 2 SCSI buses, each SCSI bus can be either internal (internal port) or external (external port), but not both. Internal devices connect to the internal ports (1 or 2) and are driven at the Ultra320 SCSI bus data rate of 320MBs. The 2 external ports have VHDCI connectors and also are driven at the Ultra320 SCSI bus date rate of 320MBs. A #1850 VHDCI to P Converter Cable is available to connect to external devices with type P connectors.

  • Attributes provided: Attachment capability of up to 2 internal SCSI devices and up to 2 external SCSI devices, maximum of 2 total.
  • Attributes required: One available 3.3 volt PCI or PCI-X slot and #0140.
  • For 9405-520: (#0645)
    • Minimum required: 0
    • Maximum allowed: 88 (Initial order maximum: 88)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#0646) - Direct Attach-5716

(No longer available as of October 16, 2004)

#0646 is ordered when the function of a #5716 is required but this card will be controlled by a Linux or AIX operating system.

Cards controlled by a Linux or AIX operating system do not use/ require PCI IOPs.

Direct attach cards are only supported in Linux or AIX LPAR partitions.

  • Attributes provided: Fibre Channel device attachment
  • Attributes required: PCI slot and #0140 and (#0142 or #0145)
  • For 9405-520: (#0646)
    • Minimum required: 0
    • Maximum allowed: 4 (Initial order maximum: 0)
    • OS level required: AIX 5L for Power V5.2 for IBM eServer, or later Red Hat Enterprise Linux AS for POWER Version 3, or later SUSE LINUX Enterprise Server 9 for POWER or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#0647) - PCI-X Disk/Tape Ctlr No IOP

Provides a PCI-X Disk/Tape SCSI Controller with zero write cache and without RAID support. A maximum of six disk drives are supported on the #0647. Removable media devices (tape, optical libraries, CD-ROM, DVD-ROM, and DVD-RAM) are also supported on the #0647.

The #0647 has two U320 buses each with a bus data rate of up to 320MBs. Each SCSI bus can be either internal (using an internal port) or external (using an external port), but not both. There are four physical ports on the #0647, two internal and two external.

Internal devices connect to the internal ports (1 or 2). External devices connect to the external ports (1 or 2) and use an LVD (Low Voltage Differential) interface and VHDCI connectors. A #1850 VHDCI to P Converter Cable is available to connect to external devices with type P connectors.

#0647, #5736, #5766 and #5775 are physically the same adapter card but have different feature numbers to indicate to IBM configurator tools how the card is being used. #0647 indicates that the card is dedicated to an AIX 5L or Linux partition and an IOP is not being used.

  • Attributes provided: Two Ultra320 SCSI VHDCI ports that may be either internal or external but not both.
  • Attributes required: One available 3.3 volt PCI or PCI-X slot
  • For 9405-520: (#0647)
    • Minimum required: 0
    • Maximum allowed: 55 (Initial order maximum: 0)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 4, or later, SUSE Linux Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#0648) - PCI-X Disk Ctlr-90MB No IOP

(No Longer Available as of October 9, 2007)

The #0648 has two Ultra320 SCSI buses each with a bus data rate of up to 320MBs. A maximum of 12 internal disk drives and up to two internal removable media devices (tape, CD-ROM, DVD-ROM or DVD-RAM) are supported on the #0648.

A minimum of three disk drives are required for RAID-5, providing protection against a single drive failure in an array. A minimum of four disk drives are required for RAID-6, providing protection against up to two drives failing in an array.

#0648, #5737, and #5776 are physically the same adapter card but have different feature numbers to indicate to IBM configurator tools how the card is being used. #0648 indicates that the card is dedicated to an AIX 5L or Linux partition and an IOP is not being used.

  • Attributes provided: Two Ultra320 SCSI VHDCI ports
  • Attributes required: One available 3.3V long PCI or PCI-X slot
  • For 9405-520: (#0648)
    • Minimum required: 0
    • Maximum allowed: 30 (Initial order maximum: 0)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 4, or later, SUSE Linux Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#0649) - Direct Attach-5583

(No longer available as of October 09, 2007)

#0649 is ordered when a #5583 is required and will be directly controlled by an AIX operating system. #0649 includes a PCI-X RAID disk controller and an auxiliary write cache IOA each with a maximum compressed write cache of 1.5GB. The disk controller and the auxiliary IOA each require one PCI-X slot and must be installed together in the same system unit or I/O unit/drawer/tower. The disk controller and the auxiliary write cache IOA are connected by a SCSI cable (provided).

The connecting SCSI cable is attached to port four of the disk controller, reducing the number of SCSI buses that support disk drives from four to three. The reduction of SCSI buses may also reduce the number of disk drives supported by the disk controller, depending on the system unit or I/O unit/drawer/tower in which the disk controller is installed. No disk drives are driven by the auxiliary write cache IOA.

#0649 can support operating system-based or application-based mirroring protection or support controller-based RAID-5 or RAID-6. Concurrent battery maintenance is supported. The controller also supports internal tape units, CD-ROM units, and DVD units. #0649 has four internal u320 SCSI buses.

#5583, #5582, and #0649 are physically the same disk controller and auxilary write cache IOA pair of cards, but have different feature numbers to denote to IBM configurator tools whether or not an IOP is required and which operating system is using them. The #0649 indicates no IOP is used and the card is directly controlled by an AIX 5L partition.

  • Attributes provided: High performance disk controller (with auxiliary write cache) with four internal Ultra320 SCSI ports.
  • Attributes required: Two single long PCI-X slots
  • For 9405-520: (#0649)
    • Minimum required: 0
    • Maximum allowed: 24 (Initial order maximum: 0)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later.
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#0650) - Direct Attach-5778

(No longer available as of October 09, 2007)

Provides an EXP24 disk controller with PCI-X DDR technology, a maximum of 1.5GB compressed write cache and a maximum 1.6GB compressed read cache. The controller supports RAID-5 and RAID-6 and mirroring is supported via operating system. Embedded auxiliary write cache and concurrent battery maintenance are provided. The controller is implemented using two physical cards that are firmly connected and requires two adjacent PCI slots. It provides three Ultra320 SCSI ports/ buses for the attachment of disk drives located in a #5786/#5787 TotalStorage EXP24 Disk Drawer/Tower.

#0650, #5739 and #5778 are physically the same adapter card but have different feature numbers to indicate to IBM configurator tools how the card is being used. #0650 indicates that the card is dedicated to an AIX 5L or Linux partition and an IOP is not being used. Other features indicate the card would be placed in the 520/ 525 system unit with a light pipe indicator, or placed in a slot which required a double-wide blind swap cassette.

  • Attributes provided: High-performance SCSI RAID Controller
  • Attributes required: Two adjacent PCI-X long card slots.
  • For 9405-520: (#0650)
    • Minimum required: 0
    • Maximum allowed: 16 (Initial order maximum: 0)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 4, or later, SUSE Linux Enterprise Server 9 for POWER, or later.
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#0651) - Direct Attach-5782

(No longer available as of October 09, 2007)

Provides an EXP24 disk controller with PCI-X DDR technology, a maximum of 1.5GB compressed write cache and a maximum 1.6GB compressed read cache. The controller supports RAID-5 and RAID-6 and mirroring is supported via operating system. Embedded auxiliary write cache and concurrent battery maintenance are provided. The controller is implemented using two physical cards that are firmly connected and requires two adjacent PCI slots. It provides three Ultra320 SCSI ports/ buses for the attachment of disk drives located in a #5786/#5787 TotalStorage EXP24 Disk Drawer/Tower.

This feature includes a double-wide blind swap cassette in which the disk controller is placed. The cassette is required to locate the disk controller in a POWER6 570 system unit or #5790/5796 I/O drawer.

#0651, #5781 and #5782 are physically the same adapter card but have different feature numbers to indicate to IBM configurator tools how the card is being used. #0651 indicates that the card is dedicated to an AIX or Linux partition in PCI slots which require a blind swap cassette and an IOP is not being used. Other features indicate the card would be placed in the 520/525 system unit with a light pipe indicator, or placed in slots which do not required a double-wide blind swap cassette.

  • Attributes provided: High-performance SCSI RAID Controller in a double wide blind swap cassette.
  • Attributes required: Two adjacent PCI-X long card slots, in a blind swap capable CEC or expansion unit.
  • For 9405-520: (#0651)
    • Minimum required: 0
    • Maximum allowed: 16 (Initial order maximum: 0)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 4, or later, SUSE Linux Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#0654) - Direct Attach-5800

(No longer available as of October 09, 2007)

Provides an EXP24 disk controller with PCI-X DDR technology, a maximum of 1.5GB compressed write cache and a maximum 1.6GB compressed read cache. The controller supports RAID-5 and RAID-6 and mirroring is supported via operating system. Embedded auxiliary write cache and concurrent battery maintenance are provided. The controller is implemented using two physical cards that are firmly connected and requires two adjacent PCI slots. It provides three Ultra320 SCSI ports/buses for the attachment of disk drives located in a #5786/#5787 TotalStorage EXP24 Disk Drawer/Tower.

This feature includes an attached "light pipe" for viewing system status LEDs and can only be placed in a system unit enclosure.

#0654, #5800 and #5799 are physically the same adapter card with light pipe, but have different feature numbers to denote to IBM configuration tools different usages. #0654 indicates the card is dedicated to an AIX or Linux parition in a 520/525 system unit. #5800/5799 indicate i5/OS usage with or without an IOP. #5739/#5778/ #0650 and #5781/#5782/#0651 are also the same adapter cards, but the #5781/#5782/#0650 indicate the adapter is placed in a double-wide blind swap cassette and #5739/#5778/#0650 indicate the adapter has a neither light pipe or cassette.

  • Attributes provided: High-performance SCSI RAID Controller
  • Attributes required: Two adjacent PCI-X long card slots.
  • For 9405-520: (#0654)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 4, or later, SUSE Linux Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#0694) - #5094 Equivalent

(No Longer Available as of July 28, 2009)

A #0694 is used by the marketing configurator to keep track of which units within a #5294/#8094 are connected to this system.

For each #5294 ordered, the marketing configurator adds two #0694 specify codes. #0694s maybe added to, or deleted from, system inventory records, but at least one #0694 must exist for each #5294 on the inventory records. If an existing #5294 is to be shared between two systems, one #0694 must be removed from the system that the #5294 was ordered against, and one #0694 must be added to the other sharing system. For each #8094 ordered, default a quantity of one #0694 specify code on the order. If the top unit of a #8094 will not attach to the same system as the lower unit, #0694 must be added to the system that has the upper unit attached. These adds and deletes are done as record purpose only (RPO) changes.

  • Attributes provided: None
  • Attributes required: At least one #5294 or the sharing of a #5294/#8094(top unit) with another system.
  • For 9405-520: (#0694)
    • Minimum required: 0
    • Maximum allowed: 6 (Initial order maximum: 6)
    • OS level required: i5/OS V5R2, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later, AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#0696) - #5096 Equivalent

(No Longer Available as of July 28, 2009)

#0696 is used by the marketing configurator to keep track of which units within a #5296 are connected to this system.

For each #5296 ordered, the marketing configurator will add two #0696 specify codes. #0696s maybe added to, or deleted from system inventory records, but at least one #0696 must exist for each #5296 on the inventory records. If an existing #5296 is to be shared between two systems, one #0696 must be removed from the system that the #5296 was ordered against, and one #0696 must be added to the other sharing system. These adds and deletes are done as record purpose only (RPO) changes.

  • Attributes provided: None
  • Attributes required: At least one #5296, or the sharing of a #5296 with another system
  • For 9405-520: (#0696)
    • Minimum required: 0
    • Maximum allowed: 6 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later, AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#0708) - Forced #5702/#5712 Placement

Ordering this specify will cause this system to have a #5702/ #5712 IOA placed in the first EADs of the system unit (CEC) so that using the Alternate Install Device Option via DST is not required.

  • Attributes required: #5702 or #5712
  • For 9405-520: (#0708)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R2, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

    Only orderable on initial systems orders and on model upgrades into the Model 520.

(#0830) - #4319 Load Source Specify

(No longer available as of August 26, 2008)

This specify code indicates that a #4319 Disk Unit is being used as the Load Source.

A load source specify code is required on each new or model upgrade order. These specifies can be changed at any time.

  • For 9405-520: (#0830)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R1, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#0834) - #4326/#1266 Load Source Spec

(No longer available as of August 26, 2008)

This specify code indicates that a #4326 Disk Unit is being used as the Load Source.

A load source specify code is required on each new or model upgrade order. These specifies can be changed at any time.

  • For 9405-520: (#0834)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R2, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#0835) - #4327/#1267 Load Source Spec

(No longer available as of February 03, 2009)

This specify code indicates that a #4327 Disk Unit is being used as the Load Source.

A load source specify code is required on each new or model upgrade order. These specifies can be changed at any time.

  • For 9405-520: (#0835)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R2, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#0836) - #4328/#1268 Load Source Spec

(No Longer Available as of October 29, 2010)

This specify code indicates that a #4328 Disk Unit is being used as the Load Source.

A load source specify code is required on each new or model upgrade order. These specifies can be changed at any time.

  • For 9405-520: (#0836)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#0837) - SAN Load Source Specify

Indicates that a SAN drive is being used as the i5/OS Load Source for the CEC enclosure.

A load source specify code is required on each new or model upgrade order into 5XX models. These codes can be changed at any time.

  • Attributes provided: Ability to load i5/OS from a SAN disk enclosure
  • Attributes required: #2847 PCI IOP with SAN Load Source and #2787 PCI-X Fibre Channel Disk Controller
  • For 9405-520: (#0837)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3 with V5R3M5 Machine Code, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#0841) - #4329/#1269 Load Source Spec

(No longer available as of January 01, 2009)

This specify code indicates that a #4329/#1269 Disk Unit is being used as the i5/OS load source.

A load source specify code is required on each new or model upgrade order. These specifies can be changed at any time.

  • Attributes provided: Load/Source indicator
  • Attributes required: i5/OS V6R1, or later
  • For 9405-520: (#0841)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: i5/OS V6R1, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#0900) - 1W Serv Feat 520 1X8950

(No longer available as of June 01, 2006)

This server feature denotes the use of one 1-way #8950 processor feature.

  • For 9405-520: (#0900)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#0901) - 1W Serv Feat 520 1X8951

(No longer available as of June 01, 2006)

#0909 is a server feature for the model 525 with one 8330 processor.

  • For 9405-520: (#0901)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#0912) - 1W Serv Feat 520 1x8972

(No longer available as of June 01, 2006)

This server solution package denotes the use of one #8972 1-way processor feature on the model 520.

  • For 9405-520: (#0912)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#0970) - 1W Serv Feat 520 1x8325/27

(No longer available as of July 08, 2008)

This server solution package denotes the use of one #8325 or #8327 1-way processor feature on a model 520.

  • For 9405-520: (#0970)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3 with V5R3M5 Machine Code, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#0983) - US TAA Compliance Indicator

This specify code indicates that the product was assembled in a manufacturing plant in the USA or in a country approved under the US Tade Agreement Act.

  • For 9405-520: (#0983)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A

(#1025) - Modem Cable - US/Canada

US/Canada modem cable use on/with #0609, #0614, #0616, #2772, #2793, #2805, #9793 adapters. Maximum of two per adapter.

  • For 9405-520: (#1025)
    • Minimum required: 0
    • Maximum allowed: 192 (Initial order maximum: 192)
    • OS level required: i5/OS V4R5, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#1266) - 35.16GB 15k rpm Disk Unit

(No longer available as of May 08, 2007)

Provides a 15k rpm disk unit with 35.16GB capacity and a SCSI interface. #1266 is installed in a #5786 TotalStorage EXP24 Disk Drawer or a #5787 TotalStorage EXP24 Disk Tower. #1266 is physically identical to a #4326 disk unit, but it has a different feature number to enable IBM configuration tools to better understand its placement.

  • Attributes provided: 35.16GB disk unit
  • Attributes required: Disk unit slot in #5786/#5787 and a disk unit controller
  • For 9405-520: (#1266)
    • Minimum required: 0
    • Maximum allowed: 277 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE Linux Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1267) - 70.56GB 15k rpm Disk Unit

(No longer available as of February 01, 2009)

Provides a 15k rpm disk unit with 70.56GB capacity and a SCSI interface. #1267 is installed in a #5786 TotalStorage EXP24 Disk Drawer or a #5787 TotalStorage EXP24 Disk Tower. #1267 is physically identical to a #4327 disk unit, but it has a different feature number to enable IBM configuration tools to better understand its placement.

  • Attributes provided: 70.56GB disk unit
  • Attributes required: Disk unit slot in #5786/#5787 and a disk unit controller
  • For 9405-520: (#1267)
    • Minimum required: 0
    • Maximum allowed: 277 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE Linux Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1268) - 141.12GB 15k rpm Disk Unit

Provides a 15k rpm disk unit with 141.12GB capacity and an Ultra320 SCSI interface. #1268 is installed in a #5786 TotalStorage EXP24 Disk Drawer or a #5787 TotalStorage EXP24 Disk Tower. #1268 is physically identical to a #4328 disk unit, but it has a different feature number to help enable IBM configuration tools to better understand its placement.

  • Attributes provided: 141.12GB disk unit
  • Attributes required: Disk unit slot in #5786/#5787 and a disk unit controller
  • For 9405-520: (#1268)
    • Minimum required: 0
    • Maximum allowed: 277 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE Linux Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1269) - 282.25GB 15k rpm Disk Unit

(No longer available as of February 01, 2009)

Provides a 15k rpm disk unit with 282.25GB of storage capacity and an Ultra320 SCSI interface speed of up to 320MBps. #1269 is installed in a #5786 TotalStorage EXP24 Disk Drawer or a #5787 TotalStorage EXP24 Disk Tower.

Note: This drive is not supported as a load source drive with i5/OS V5R4 with machine code V5R4M5 or earlier.

  • Attributes provided: 282.25GB 15k rpm disk unit.
  • Attributes required: One disk drive bay in a #5786 or #5787.
  • For 9405-520: (#1269)
    • Minimum required: 0
    • Maximum allowed: 138 (Initial order maximum: 0)
    • OS level required: i5/OS V5R4, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1292) - 300GB 15k rpm Disk Unit

(No longer available as of February 01, 2009)

Provides a 15k rpm disk unit with 300GB of storage capacity and an Ultra320 SCSI interface speed of up to 320MBps. #1292 is installed in a #5786 TotalStorage EXP24 Disk Drawer or a #5787 TotalStorage EXP24 Disk Tower.

  • Attributes provided: 300GB 15k rpm disk unit.
  • Attributes required: One disk drive bay in a #5786 or #5787.
  • For 9405-520: (#1292)
    • Minimum required: 0
    • Maximum allowed: 130 (Initial order maximum: 0)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 4 with quarterly update 3, or later, SUSE Linux Enterprise Server 9 for POWER with service pack 3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1293) - 36.4GB 10k rpm Disk Unit

(No longer available as of February 06, 2007)

Provides a 10k rpm disk unit with 36.4GB of storage capacity and an industry standard Ultra320 SCSI interface speed of up to 320MBps. #1293 is installed in a #5786 TotalStorage EXP24 Disk Drawer or a #5787 TotalStorage EXP24 Disk Tower. #1293 is physically identical to a #1893 disk unit, but it has a different feature number to enable IBM configuration tools to better understand its placement.

  • Attributes provided: 36.4 GB disk unit.
  • Attributes required: One disk drive bay in a #5786 or #5787.
  • For 9405-520: (#1293)
    • Minimum required: 0
    • Maximum allowed: 277 (Initial order maximum: 0)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 4 with quarterly update 3, or later, SUSE Linux Enterprise Server 9 for POWER with service pack 3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1294) - 73.4GB 10k rpm Disk Unit

(No longer available as of May 08, 2007)

Provides a 10k rpm disk unit with 73.4GB of storage capacity and an industry standard Ultra320 SCSI interface speed of up to 320MBps. #1294 is installed in a #5786 TotalStorage EXP24 Disk Drawer or a #5787 TotalStorage EXP24 Disk Tower. #1294 is physically identical to a #1894 disk unit, but it has a different feature number to enable IBM configuration tools to better understand its placement.

  • Attributes provided: 73.4GB disk unit.
  • Attributes required: One disk drive bay in a #5786 or #5787.
  • For 9405-520: (#1294)
    • Minimum required: 0
    • Maximum allowed: 277 (Initial order maximum: 0)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 4 with quarterly update 3, or later, SUSE Linux Enterprise Server 9 for POWER with service pack 3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1295) - 146.8GB 10k rpm Disk Unit

(No longer available as of May 08, 2007)

Provides a 10k rpm disk unit with 146.8GB of storage capacity and an industry standard Ultra320 SCSI interface speed of up to 320MBps. #1295 is installed in a #5786 TotalStorage EXP24 Disk Drawer or a #5787 TotalStorage EXP24 Disk Tower. #1295 is physically identical to a #1895 disk unit, but it has a different feature number to enable IBM configuration tools to better understand its placement.

  • Attributes provided: 146.8GB of disk storage mounted in a carrier.
  • Attributes required: One disk drive bay in a #5786 or #5787.
  • For 9405-520: (#1295)
    • Minimum required: 0
    • Maximum allowed: 277 (Initial order maximum: 0)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 4 with quarterly update 3, or later, SUSE Linux Enterprise Server 9 for POWER with service pack 3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1296) - 36.4GB 15k rpm Disk Unit

(No longer available as of May 08, 2007)

Provides a 15k rpm disk unit with 36.4GB of storage capacity and an industry standard Ultra320 SCSI interface speed of up to 320MBps. #1296 is installed in a #5786 TotalStorage EXP24 Disk Drawer or a #5787 TotalStorage EXP24 Disk Tower. #1296 is physically identical to a #1896 disk unit, but it has a different feature number to enable IBM configuration tools to better understand its placement.

  • Attributes provided: 36.4GB disk unit
  • Attributes required: One disk drive bay in a #5786 or #5787
  • For 9405-520: (#1296)
    • Minimum required: 0
    • Maximum allowed: 277 (Initial order maximum: 0)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 4 with quarterly update 3, or later, SUSE Linux Enterprise Server 9 for POWER with service pack 3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1297) - 73.4GB 15k rpm Disk Unit

(No longer available as of February 01, 2009)

Provides a 15k rpm disk unit with 73.4GB of storage capacity and an industry standard Ultra320 SCSI interface speed of up to 320MBps. #1297 is installed in a #5786 TotalStorage EXP24 Disk Drawer or a #5787 TotalStorage EXP24 Disk Tower. #1297 is physically identical to a #1897 disk unit, but it has a different feature number to enable IBM configuration tools to better understand its placement.

  • Attributes provided: 73.4GB disk unit
  • Attributes required: One disk drive bay in a #5786 or #5787
  • For 9405-520: (#1297)
    • Minimum required: 0
    • Maximum allowed: 277 (Initial order maximum: 0)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 4 with quarterly update 3, or later, SUSE Linux Enterprise Server 9 for POWER with service pack 3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1298) - 146.8GB 15k rpm Disk Unit

Provides a 15k rpm disk unit with 146.8GB of storage capacity and an industry standard Ultra320 SCSI interface speed of up to 320MBps. #1298 is installed in a #5786 TotalStorage EXP24 Disk Drawer or a #5787 TotalStorage EXP24 Disk Tower. #1298 is physically identical to a #1898 disk unit, but it has a different feature number to enable IBM configuration tools to better understand its placement.

  • Attributes provided: 146.8GB of disk storage mounted in a carrier.
  • Attributes required: One disk drive bay in a #5786 or #5787.
  • For 9405-520: (#1298)
    • Minimum required: 0
    • Maximum allowed: 266 (Initial order maximum: 0)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 4 with quarterly update 3, or later, SUSE Linux Enterprise Server 9 for POWER with service pack 3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1299) - 300GB 10k rpm Disk Unit

(No longer available as of October 24, 2007)

Provides a 10k rpm disk unit with 300GB of storage capacity and an industry standard Ultra320 SCSI interface speed of up to 320MBps. #1299 is installed in a #5786 TotalStorage EXP24 Disk Drawer or a #5787 TotalStorage EXP24 Disk Tower. #1299 is physically identical to a #3578 disk unit, but it has a different feature number to enable IBM configuration tools to better understand its placement.

  • Attributes provided: 300GB 10k rpm disk unit.
  • Attributes required: One disk drive bay in a #5786 or #5787.
  • For 9405-520: (#1299)
    • Minimum required: 0
    • Maximum allowed: 130 (Initial order maximum: 0)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 4 with quarterly update 3, or later, SUSE Linux Enterprise Server 9 for POWER with service pack 3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1307) - 1.75m HSL-2/RIO-2 Cable

(No longer available as of December 01, 2008)

This feature provides a 1.75m HSL-2/RIO-G cable for use in connecting a tower/system unit with an HSL-2/RIO-G port to a tower/ system unit with an HSL-2/RIO-G port.

  • Attributes provided:
  • Attributes requires:
  • For 9405-520: (#1307)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: i5/OS V5R3, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later, AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1308) - 2.5m HSL-2/RIO-2 Cable

(No Longer Available as of October 14, 2011)

This feature provides a 1.75m HSL-2/RIO-G cable for use in connecting a tower/system unit with an HSL-2/RIO-G port to a tower/ system unit with an HSL-2/RIO-G port.

  • For 9405-520: (#1308)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: i5/OS V5R3, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later, AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#1311) - System Unique Identifier

After 255 scratch in stalls, the system ID counter wraps and a new system ID must be created. Feature #1311 can be ordered as an MES to regenerate a customer's system ID.

  • For 9405-520: (#1311)
    • Minimum required: 0
    • Maximum allowed: 1PO (Initial order maximum: 0)
    • OS level required: i5/OS V3R6, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#1406) - 200V 16A 14-Ft TL Line Cord

(No longer available as of January 31, 2008)

  • For 9405-520: (#1406)
    • Minimum required: 0
    • OS level required: i5/OS V4R4, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1410) - 200V 6-Ft Line Cord

(No longer available as of January 31, 2008)

  • For 9405-520: (#1410)
    • Minimum required: 0
    • OS level required: i5/OS V4R5, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later, AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1411) - 200V 14-Ft Line Cord

(No longer available as of January 31, 2008)

  • For 9405-520: (#1411)
    • Minimum required: 0
    • OS level required: i5/OS V4R5, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1412) - 125V 6-Ft Line Cord

(No longer available as of January 31, 2008)

  • For 9405-520: (#1412)
    • Minimum required: 0
    • OS level required: i5/OS V4R5, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later, AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1414) - 200V 6-Ft Locking Line Cord

(No longer available as of January 31, 2008)

  • For 9405-520: (#1414)
    • Minimum required: 0
    • OS level required: i5/OS V4R5, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1415) - 200V 6-Ft Wtrtght Line Cord

(No longer available as of January 31, 2008)

  • For 9405-520: (#1415)
    • Minimum required: 0
    • OS level required: i5/OS V4R5, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1422) - 3m IEC 320 C13/14 PDU Cord

(No longer available as of January 31, 2008)

#1422 power cord is used from a racked device to a #5160/#5161/ #5162/5163/7188 Power Distribution Unit in that same rack. The replacement PDU cord is #6671.

  • For 9405-520: (#1422)
    • Minimum required: 0
    • OS level required: i5/OS V5R1, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1426) - 200V 14-Ft Locking Line Cord

(No longer available as of January 15, 2005)

  • For 9405-520: (#1426)
    • Minimum required: 0
    • OS level required: i5/OS V4R5, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1427) - 200V 14-Ft Wtrtght Line Cord

(No longer available as of January 15, 2005)

  • For 9405-520: (#1427)
    • Minimum required: 0
    • OS level required: i5/OS V4R5, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1451) - 200V 6-Ft Line Cord

(No longer available as of December 01, 2008)

This feature provides a 6-ft 200V line cord.

  • For 9405-520: (#1451)
    • Minimum required: 0
    • OS level required: i5/OS V4R5, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1452) - 200V 14-Ft Line Cord

(No Longer Available as of October 2, 2009)

This feature provides a 14-ft line cord.

  • For 9405-520: (#1452)
    • Minimum required: 0
    • OS level required: i5/OS V4R5, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#1453) - 200V 6-Ft Locking Line Cord

(No longer available as of December 01, 2008)

This feature provides a 14-ft locking line cord.

  • For 9405-520: (#1453)
    • Minimum required: 0
    • OS level required: i5/OS V4R5, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1454) - 200V 12A 14-Ft TL Line Cord

(No Longer Available as of October 2, 2009)

This feature provides a 12amp 14-ft TF line cord.

  • For 9405-520: (#1454)
    • Minimum required: 0
    • OS level required: i5/OS V4R5, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#1455) - 200V 6-Ft Wtrtght Line Cord

(No longer available as of December 01, 2008)

This feature provides a 6-ft watertight line cord.

  • For 9405-520: (#1455)
    • Minimum required: 0
    • OS level required: i5/OS V4R5, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1456) - 200V 14-Ft Wtrtght Line Cord

(No Longer Available as of October 2, 2009)

This feature provides a 14-ft watertight line cord.

  • For 9405-520: (#1456)
    • Minimum required: 0
    • OS level required: i5/OS V4R5, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#1457) - 200V 6-Ft Upper Line Cord

(No longer available as of January 31, 2008)

  • For 9405-520: (#1457)
    • Minimum required: 0
    • OS level required: i5/OS V4R5, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1458) - 200V 6-Ft Upper Locking Cord

(No longer available as of January 31, 2008)

  • For 9405-520: (#1458)
    • Minimum required: 0
    • OS level required: i5/OS V5R3, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1459) - 200V 6-Ft Upper Wtrtght Cord

(No longer available as of December 01, 2008)

This feature provides a 6-ft upper watertight line cord.

  • For 9405-520: (#1459)
    • Minimum required: 0
    • OS level required: i5/OS V4R5, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1460) - 3m Copper HSL/RIO Cable

(No Longer Available as of October 2, 2009)

This feature provides a 3m HSL/RIO cable for use in connecting a tower/CEC unit with an HSL/RIO port to a tower/CEC unit with an HSL/ RIO port.

  • For 9405-520: (#1460)
    • Minimum required: 0
    • OS level required: i5/OS V4R5, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#1461) - 6m Copper HSL/RIO Cable

(No Longer Available as of October 2, 2009)

This feature provides a 6m HSL/RIO cable for use in connecting a tower/CEC unit with an HSL/RIO port to a tower/CEC unit with an HSL/ RIO port.

  • For 9405-520: (#1461)
    • Minimum required: 0
    • OS level required: i5/OS V4R5, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#1462) - 15m Copper HSL/RIO Cable

(No Longer Available as of October 2, 2009)

This feature provides a 15m HSL/RIO cable for use in connecting a tower/CEC unit with an HSL/RIO port to a tower/CEC unit with an HSL/ RIO port.

  • For 9405-520: (#1462)
    • Minimum required: 0
    • OS level required: i5/OS V4R5, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#1474) - 6m HSL/RIO to HSL2/RIO2 Cbl

(No Longer Available as of October 2, 2009)

This feature provides a 6m HSL/RIO to HSL-2/RIO-G Cable for use in connecting a tower/CEC unit with an HSL/RIO port to a tower/CEC unit with an HSL-2/RIO-G port.

  • Attributes provided: One HSL/RIO to HSL-2/RIO-G cable
  • Attributes required: One HSL/RIO port and one HSL-2/RIO-G port
  • For 9405-520: (#1474)
    • Minimum required: 0
    • OS level required: i5/OS V5R2, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#1475) - 10m HSL/RIO to HSL2/RIO2 Cbl

(No Longer Available as of October 2, 2009)

This feature provides a 10m HSL/RIO to HSL-2/RIO-G Cable for use in connecting a tower/CEC unit with an HSL/RIO port to a tower/CEC unit with an HSL-2/RIO-G port.

  • For 9405-520: (#1475)
    • Minimum required: 0
    • OS level required: i5/OS V5R2, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#1481) - 1.2m HSL-2/RIO-2 Cable

(No Longer Available as of May 27, 2011)

This feature provides a 1.2m HSL-2/RIO-G Cable for use in connecting a tower/CEC unit with an HSL-2/RIO-G port to another tower/CEC unit with an HSL-2/RIO-G port.

  • For 9405-520: (#1481)
    • Minimum required: 0
    • OS level required: i5/OS V5R3, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later, AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#1482) - 3.5m HSL-2/RIO-2 Cable

(No Longer Available as of May 27, 2011)

This feature provides a 3.5m HSL-2/RIO-G Cable for use in connecting a tower/CEC unit with an HSL-2/RIO-G port to another tower/CEC unit with an HSL-2/RIO-G port.

  • For 9405-520: (#1482)
    • Minimum required: 0
    • OS level required: i5/OS V5R2, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later, AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#1483) - 10m HSL-2/RIO-2 Cable

(No Longer Available as of May 27, 2011)

This feature provides a 10m HSL-2/RIO-G Cable for use in connecting a tower/CEC unit with an HSL-2/RIO-G port to another tower/CEC unit with an HSL-2/RIO-G port.

  • For 9405-520: (#1483)
    • Minimum required: 0
    • OS level required: i5/OS V5R2, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later, AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#1485) - 15m HSL-2/RIO-2 Cable

(No Longer Available as of May 27, 2011)

This feature provides a 15m HSL-2/RIO-G Cable for use in connecting a tower/CEC unit with an HSL-2/RIO-G port to another tower/CEC unit with an HSL-2/RIO-G port. This cable should be used only when greater distance is required as in certain environments, there could be some performance degradation compared to the shorter cable.

  • For 9405-520: (#1485)
    • Minimum required: 0
    • Maximum allowed: 10 (Initial order maximum: 10)
    • OS level required: i5/OS V5R2, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later, AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#1487) - 3m HSL/RIO to HSL2/RIO2 Cbl

(No Longer Available as of October 2, 2009)

A 3m HSL/RIO to HSL-2/RIO-G Cable to connect a tower/CEC unit with an HSL/RIO port to a tower/CEC unit with an HSL-2/RIO-G port.

  • Attributes provided: One HSL/RIO to HSL-2/RIO-G cable
  • Attributes required: One HSL/RIO port and one HSL-2/RIO-G port
  • For 9405-520: (#1487)
    • Minimum required: 0
    • OS level required: n/a
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#1700) - IPCS Keyboard/Mouse for NT

(No longer available as of June 01, 2006)

This feature provides a keyboard and mouse for use on the IXS which is required for running the Windows operating system.

Note: Some IXS can support USB keyboards, the keyboard provided with this feature is a standard attached keyboard, not a USB attached keyboard.

  • For 9405-520: (#1700)
    • Minimum required: 0
    • Maximum allowed: 18 (Initial order maximum: 18)
    • OS level required: i5/OS V4R1, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1827) - Serial-UPS Conversion Cable

#1827 is a 0.14M adapter cable with a female 9-pin D-shell connector on each end. #1827 converts the CEC serial port 2 to a SPCN/UPS port, providing an additional port for UPS control.

The mode of the port cannot be changed during runtime, a re-IPL is required to change the mode once the adapter cable is connected or disconnected.

  • Attributes provided: One additional SPCN/UPS port
  • Attributes required: CEC serial port 2
  • For 9405-520: (#1827)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#1850) - VHDCI to P Converter Cable

(No longer available as of September 12, 2006)

The #1850 VHDCI to P Converter Cable is used to convert from a Mini-68 pin VHDCI connector to a 68-pin P style connector. The cable has a male Mini-68 pin VHDCI connector on one end and a female 68 pin P style connector on the other. Length = 0.3 meters.

  • Attributes provided: Attachment of supported SCSI external device with P style connecter to an integrated SCSI adapter with VHDCI Mini-68 pin connector.
  • Attributes required: None
  • For 9405-520: (#1850)
    • Minimum required: 0
    • OS level required: AIX 5L for Power V3, or later for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1851) - 0.6m SCSI P-P Cable

(No longer available as of January 15, 2005)

The #1851 0.6m SCSI P-P Cable provides a 16-bit connection between any two differential or single ended SCSI devices having 68-pin connectors. It can be used to attach an external SCSI device to a SCSI adapter card.

  • Attributes provided: 0.6 meter SCSI cable with 68-pin connectors at each end
  • Attributes required: 68-pin SCSI Interface
  • For 9405-520: (#1851)
    • Minimum required: 0
    • OS level required: AIX 5L for Power V3 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER or later AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1852) - 2.5m SCSI P-P Cable

(No longer available as of September 12, 2006)

The #1852 2.5m SCSI P-P Cable provides a 16-bit connection between any two differential or single ended SCSI devices having 68-pin connectors. It can be used to attach an external SCSI device to a SCSI adapter card.

  • Attributes provided: 2.5 meter SCSI cable with 68-pin connectors at each end
  • Attributes required: 68-pin SCSI Interface
  • For 9405-520: (#1852)
    • Minimum required: 0
    • OS level required: AIX 5L for Power V3 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER or
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1855) - 4-port EIA 232 Cable

(No longer available as of June 23, 2006)

The #1855 4-port EIA 232 Cable provides 4 ports of EIA 232 connectivity for the #2947 PCI Multiprotocol Adapter.

  • Attributes provided: 4-port EIA-232 cable for #2947
  • Attributes required: One #2947 adapter
  • For 9405-520: (#1855)
    • Minimum required: 0
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1860) - ASYNC Terminal/Prt Cable

(No Longer Available as of July 29, 2011)

The #1860 ASYNC Terminal/Prt Cable is a 4-meter cable and transposer (2 parts) that allows external async devices such as printers or terminals to be attached directly to a 9-pin serial port.

  • Attributes provided: None
  • Attributes required: None
  • For 9405-520: (#1860)
    • Minimum required: 0
    • OS level required: Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later, AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#1870) - USB Keyboard-Dutch

(No longer available as of May 08, 2007)

This feature provides a USB attached Dutch #143 keyboard.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#1870)
    • Minimum required: 0
    • OS level required: AIX 5L for Power V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1871) - USB Keybd-Bulgarian

(No longer available as of May 08, 2007)

The #1871 provides a USB attached Bulgarian #442 keyboard.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#1871)
    • Minimum required: 0
    • OS level required: Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later, AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1872) - USB Keyboard-Portuguese

(No longer available as of May 08, 2007)

The #1872 provides a USB attached Portuguese #163 keyboard.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#1872)
    • Minimum required: 0
    • OS level required: Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later, AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1873) - Dwr to Dwr Serial Cable

The #1873 is a 3.7 meter cable that provides a null-modem connection between the serial ports of two system drawers that are mounted within the same rack. The cable has a DB25 female connector at each end.

  • Attributes provided: Two drawers connected by serial ports
  • Attributes required: Two drawers with available serial ports on each drawer
  • For 9405-520: (#1873)
    • Minimum required: 0
    • OS level required: Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later, AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#1874) - Rack to Rack Serial Cable

The #1874 is an 8 meter cable that provides a null-modem connection between the serial ports of two system drawers that are mounted in separate racks. The cable has a DB25 female connector at each end.

  • Attributes provided: Two drawers connected by serial ports
  • Attributes required: Two drawers with available serial ports on each drawer
  • For 9405-520: (#1874)
    • Minimum required: 0
    • OS level required: Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later, AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#1875) - Serial Port Converter Cable

The #1875 cable converts the 9-pin serial port on the system to a 25-pin serial port that allows the user to attach 25-pin serial devices to the system.

  • Attributes provided: 25-pin serial port on system
  • Attributes required: Available 9-pin serial port on system
  • For 9405-520: (#1875)
    • Minimum required: 0
    • OS level required: Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later, AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#1876) - L200P Flat Panel Monitor

(No longer available as of May 02, 2006)

The #1876 L200p Flat Panel Monitor has the following general characteristics:

  • Business black color
  • 20.1-inch TFT LCD digital screen with a viewable image size of 510 mm (20.1 inches) measured diagonally, incorporating a 0.255 mm pixel pitch/type for bright, high-definition images.
  • Designed to provide flicker free operation at a maximum resolution of 1600 x 1200 pels at 75Hz in analog mode and 1600 x 1200 pels at 60Hz in digital mode.
  • Tilt/swivel stand
  • Attributes provided: Color Flat-panel Monitor
  • Attributes required: Graphics Adapter
  • For 9405-520: (#1876)
    • Minimum required: 0
    • OS level required: Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later, AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1889) - 80GB VXA-2 Tape Drive

(No longer available as of May 08, 2007)

#1889 80GB VXA-2 Tape Drive is a 5.25-inch, half-high, Ultra2 LVD 16-bit tape drive, which provides a high capacity for save/restore and archive functions. This tape drive uses VXA tape data cartridges and is compression capable, providing a capacity of up to 160 GB.

Characteristics:

  • Capacity: 80GB native mode, 160GB (typical) compression mode
  • Form Factor: 5.25-inch half high
  • Media: uses VXA tape data cartridges
  • Technology: Helical scan, rotating head
  • Operation: Streaming
  • Data Transfer Rate: 6MBps native mode, 12MBps (typical) compression
  • Interface: SCSI-2 (LVD/SE) asynchronous/synchronous
  • Compatability: 80GB mode (Read/Write), 160GB compression (Read/Write)
  • Attributes provided: One 80GB internal VXA-2 tape drive
  • Attributes required: One 1.6-inch (41mm) half-high media bay and one SCSI-2 internal 16-bit address
  • For 9405-520: (#1889)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later, AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1893) - 36.4GB 10k rpm Disk Unit

(No longer available as of April 15, 2005)

The #1893 36.4 GB 10,000 RPM Ultra320 SCSI Disk Drive Assembly provides 36.4 GB of storage capacity and supports the industry standard Ultra320 SCSI interface speed of up to 320 MBps.

Characteristics:

  • Form Factor: 3.5-inch, 1-inch (25 mm) high
  • Cable included: No
  • External Interface: Ultra320 SCSI (16-bit, Low Voltage Differential)
  • Attachment Industry Spec: SCSI U320
  • Average Seek Time: 4.82 ms (based on four(4) READS to one(1) WRITE)
  • Average Latency: 2.99 ms
  • Rotational Speed: 10,000 RPM
  • Maximum Data Transfer Rate: 67 MBps

Limitation: This disk drive requires attachment to a supported Ultra320 SCSI Adapter in an system that supports an Ultra320 SCSI cable/backplane in order for the drive to run at 320 MBps. Also, any and all other SCSI devices on the same SCSI bus must also be Ultra2, Ultra3, or Ultra320 SCSI device(s) in order for this disk drive to run at 320 MBps.

  • Attributes provided: 36.4 GB of disk storage mounted in a carrier.
  • Attributes required: One disk drive bay.
  • For 9405-520: (#1893)
    • Minimum required: 0
    • Maximum allowed: 278 (Initial order maximum: 278)
    • OS level required: AIX 5L for POWER V3 for IBM eServer, or later Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later,
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1894) - 73.4GB 10k rpm Disk Unit

(No longer available as of July 13, 2007)

The #1894 73.4 GB 10,000 RPM Ultra320 SCSI Disk Drive Assembly provides 73.4 GB of storage capacity and supports the industry standard Ultra320 SCSI interface speed of up to 320 MBps.

Characteristics:

  • Form Factor: 3.5-inch, 1-inch (25 mm) high

  • Cable included: No

  • External Interface: Ultra320 SCSI (16-bit, Low Voltage Differential)

  • Attachment Industry Spec: SCSI U320

  • Average Seek Time: 4.82 ms (based on four(4) READS to one(1) WRITE)

  • Average Latency: 2.99 ms

  • Rotational Speed: 10,000 RPM

  • Maximum Data Transfer Rate: 67 MBps

Limitation: This disk drive requires attachment to a supported Ultra320 SCSI Adapter in an system that supports an Ultra320 SCSI cable/backplane in order for the drive to run at 320 MBps. Also, any and all other SCSI devices on the same SCSI bus must also be Ultra2, Ultra3, or Ultra320 SCSI device(s) in order for this disk drive to run at 320 MBps.

  • Attributes provided: 73.4 GB of disk storage mounted in a carrier.
  • Attributes required: One disk drive bay.
  • For 9405-520: (#1894)
    • Minimum required: 0
    • Maximum allowed: 278 (Initial order maximum: 278)
    • OS level required: AIX 5L for Power V3 for IBM eServer, or later Red Hat Enterprise Linux AS for POWER Version 3, or later SUSE LINUX Enterprise Server 9 for POWER or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1895) - 146.8GB 10k rpm Disk Unit

(No longer available as of July 13, 2007)

The #1895 146.8 GB 10,000 RPM Ultra320 SCSI Disk Drive Assembly provides 146.8 GB of storage capacity and supports the industry standard Ultra320 SCSI interface speed of up to 320 MBps.

Characteristics:

  • Form Factor: 3.5-inch, 1-inch (25 mm) high
  • Cable included: No
  • External Interface: Ultra320 SCSI (16-bit, Low Voltage Differential)
  • Attachment Industry Spec: SCSI U320
  • Average Seek Time: 4.94 ms (based on four(4) READS to one(1) WRITE)
  • Average Latency: 2.99 ms
  • Rotational Speed: 10,000 RPM
  • Maximum Data Transfer Rate: 67 MBps

Limitation: This disk drive requires attachment to a supported Ultra320 SCSI Adapter in a system that supports an Ultra320 SCSI cable/backplane in order for the drive to run at 320 MBps. Also, any and all other SCSI devices on the same SCSI bus must also be Ultra2, Ultra3, or Ultra320 SCSI device(s) in order for this disk drive to run at 320 MBps.

  • Attributes provided: 146.8 GB of disk storage mounted in a carrier.
  • Attributes required: One disk drive bay.
  • For 9405-520: (#1895)
    • Minimum required: 0
    • Maximum allowed: 278 (Initial order maximum: 278)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1896) - 36.4GB 15k rpm Disk Unit

(No longer available as of May 08, 2007)

The #1896 36.4 GB 15,000 RPM Ultra320 SCSI Disk Drive Assembly provides 36.4 GB of storage capacity and supports the industry standard Ultra320 SCSI interface speed of up to 320 MBps.

Characteristics:

  • Form Factor: 3.5-inch, 1-inch (25 mm) high
  • Cable included: No
  • External Interface: Ultra320 SCSI (16-bit, Low Voltage Differential)
  • Attachment Industry Spec: SCSI U320
  • Average Seek Time: 3.7 ms (based on four(4) READS to one(1) WRITE)
  • Average Latency: 2 ms
  • Rotational Speed: 15,000 RPM
  • Maximum Data Transfer Rate: 83 MBps

Limitation: This disk drive requires attachment to a supported Ultra320 SCSI Adapter in a system that supports an Ultra320 SCSI cable/backplane in order for the drive to run at 320 MBps. Also, any and all other SCSI devices on the same SCSI bus must also be Ultra2, Ultra3, or Ultra320 SCSI device(s) in order for this disk drive to run at 320 MBps.

  • Attributes provided: 36.4 GB of disk storage mounted in a carrier.
  • Attributes required: One disk drive bay.
  • For 9405-520: (#1896)
    • Minimum required: 0
    • Maximum allowed: 278 (Initial order maximum: 278)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1897) - 73.4GB 15k rpm Disk Unit

(No longer available as of February 01, 2009)

The #1897 73.4GB 15,000 RPM Ultra320 SCSI Disk Drive Assembly provides 73.4 GB of storage capacity and supports the industry standard Ultra320 SCSI interface speed of up to 320MBps.

Characteristics:

  • Form Factor: 3.5-inch, 1-inch (25 mm) high
  • Cable included: No
  • External Interface: Ultra320 SCSI (16-bit, Low Voltage Differential)
  • Attachment Industry Spec: SCSI U320
  • Average Seek Time: 3.7ms (based on four(4) READS to one(1) WRITE)
  • Average Latency: 2ms
  • Rotational Speed: 15,000 RPM
  • Maximum Data Transfer Rate: 83MBps

Limitation: This disk drive requires attachment to a supported Ultra320 SCSI Adapter in a system that supports an Ultra320 SCSI cable/backplane in order for the drive to run at 320 MBps. Also, any and all other SCSI devices on the same SCSI bus must also be Ultra2, Ultra3, or Ultra320 SCSI device(s) in order for this disk drive to run at 320MBps.

  • Attributes provided: 73.4 GB of disk storage mounted in a carrier.
  • Attributes required: One disk drive bay.
  • For 9405-520: (#1897)
    • Minimum required: 0
    • Maximum allowed: 278 (Initial order maximum: 278)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#1898) - 146.8GB Disk Unit

Provides a 15,000 rpm disk unit with 146.8GB of storage capacity for AIX 5L and Linux partitions.

Characteristics:

  • Form factor: 3.5-inch, 1-inch (25 mm) high
  • Cable included: No
  • External interface: Ultra320 SCSI (16-bit, Low Voltage Differential)
  • Attachment Industry Spec: SCSI U320
  • Average seek time: 3.7 ms (based on four reads to one write)
  • Average latency: 2 ms
  • Rotational speed: 15,000 rpm
  • Maximum data transfer rate: 83 MBps

Limitation: This disk drive requires attachment to a supported Ultra320 SCSI adapter in a system that supports an Ultra320 SCSI cable/backplane in order for the drive to run at 320MBps. Also, any and all other SCSI devices on the same SCSI bus must also be Ultra2, Ultra3, or Ultra320 SCSI devices in order for this disk drive to run at 320MBps.

  • Attributes provided: 146.8GB of disk storage mounted in a carrier.
  • Attributes required: One disk drive bay.
  • For 9405-520: (#1898)
    • Minimum required: 0
    • Maximum allowed: 56 (Initial order maximum: 0)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#2114) - Ext Diff SCSI y-Cable

(No longer available as of June 23, 2006)

  • Attributes provided: Attachment of multiple hosts to the PCI SCSI-2 differential adapter
  • Attributes required: 1 external SCSI-2 Fast/Wide Port
  • For 9405-520: (#2114)
    • Minimum required: 0
    • OS level required: Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later, AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#2124) - 1m SCSI Cable

(No Longer Available as of November 26, 2010)

Provides a 1m Ultra320 SCSI cable that connects an external SCSI port on a disk controller to a #5741/#5742 Disk Slot Enabler in a #5786/#5787 TotalStorage EXP24 Disk Drawer/Tower.

  • Attributes provided: Attachment of #5786/#5787 TotalStorage EXP24 Disk Drawer/Tower
  • Attributes required: SCSI disk controller and a #5786 or a #5787
  • For 9405-520: (#2124)
    • Minimum required: 0
    • Maximum allowed: 47 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE Linux Enterprise Server 9 for POWER, or later.
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#2125) - 3m SCSI Cable

(No Longer Available as of November 26, 2010)

Provides a 3m Ultra320 SCSI cable that connects an external SCSI #5786/#5787 TotalStorage EXP24 Disk Drawer/Tower.

  • Attributes provided: Attachment of #5786/#5787 TotalStorage EXP24 Disk Drawer/Tower
  • Attributes required: SCSI disk controller and a #5786 or a #5787
  • For 9405-520: (#2125)
    • Minimum required: 0
    • Maximum allowed: 47 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE Linux Enterprise Server 9 for POWER, or later.
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#2126) - 5m SCSI Cable

(No Longer Available as of November 27, 2009)

Provides a 5m Ultra320 SCSI cable that connects an external SCSI port on a disk controller to a #5741/#5742 Disk Slot Enabler in a #5786/#5787 TotalStorage EXP24 Disk Drawer/Tower.

  • Attributes provided: Attachment of #5786/#5787 TotalStorage EXP24 Disk Drawer/Tower
  • Attributes required: SCSI disk controller and a #5786 or a #5787
  • For 9405-520: (#2126)
    • Minimum required: 0
    • Maximum allowed: 47 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE Linux Enterprise Server 9 for POWER, or later.
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#2127) - 10m SCSI Cable

(No Longer Available as of November 27, 2009)

Provides a 10m Ultra320 SCSI cable that connects an external SCSI port on a disk controller to a #5741/#5742 Disk Slot Enabler in a #5786/#5787 TotalStorage EXP24 Disk Drawer/Tower.

  • Attributes provided: Attachment of #5786/#5787 TotalStorage EXP24 Disk Drawer/Tower
  • Attributes required: SCSI disk controller and a #5786 or a #5787
  • For 9405-520: (#2127)
    • Minimum required: 0
    • Maximum allowed: 47 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE Linux Enterprise Server 9 for POWER, or later.
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#2128) - 20m SCSI Cable

(No Longer Available as of November 26, 2010)

Provides a 20m Ultra320 SCSI cable that connects an external SCSI port on a disk controller to a #5741/#5742 Disk Slot Enabler in a #5786/#5787 TotalStorage EXP24 Disk Drawer/Tower.

  • Attributes provided: Attachment of #5786/#5787 TotalStorage EXP24 Disk Drawer/Tower
  • Attributes required: SCSI disk controller and a #5786 or a #5787
  • For 9405-520: (#2128)
    • Minimum required: 0
    • Maximum allowed: 47 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE Linux Enterprise Server 9 for POWER, or later.
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#2138) - 0.55m SCSI Cable

(No Longer Available as of November 26, 2010)

Provides a 0.55m Ultra320 SCSI cable that can connect to an external SCSI port on a disk controller, a #5741/#5742 Disk Slot Enabler in a #5786/#5787 TotalStorage EXP24 Disk Drawer/Tower or between a #5741 and #5742 in a #5786/#5787 TotalStorage EXP24 Disk Drawer/Tower for the purpose of daisy-chaining disk unit bays together.

  • Attributes provided: SCSI connectivity to #5786/#5787 TotalStorage EXP24 Disk Drawer/ Tower disk bays.
  • Attributes required: A #5786 or a #5787.
  • For 9405-520: (#2138)
    • Minimum required: 0
    • Maximum allowed: 23 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 4, or later, SUSE Linux Enterprise Server 9 for POWER, or later.
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#2591) - Ext 1.44GB Diskette Drive

(No longer available as of August 28, 2009)

The #2591 externally attached USB diskette drive provides storage capacity up to 1.44 MB on a high density (2HD) floppy disk and 720 KB on a double density diskette. Includes 350mm (13.7 in) captured cable with standard USB connector.

Limitations:

  • Maximum 1 USB diskette per adapter
  • Up to 1 Keyboard and Mouse are supported concurrently on the adapter
  • No system boot capability
  • Not to be operated upside down or with eject button down

Characteristics:

  • Capacity - 1.44 MB (2HD disk) or 720 KB (double density disk)
  • Physical Dimensions: Width=103mm (4.05 in), Height=17.6mm (.69 in)
  • Depth=141.8mm (5.58 in)
  • Color: Black
  • Data Rate: 12 Mbits/sec
  • Max Power Consumption: 2.36 Watt (seek)
  • Operates in all positions except those noted above.
  • Attributes provided: External diskette drive
  • Attributes required: 1 available USB port
  • For 9405-520: (#2591)
    • Minimum required: 0
    • Maximum allowed: 88 (Initial order maximum: 88)
    • OS level required: Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later, AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#2640) - DVD-ROM

(No longer available as of May 29, 2009)

The 8X/24X(max) Slimline IDE DVD-ROM Drive is an internal tray loading DVD-ROM drive providing up to 3600KB/sec (CD-ROM) and 10.3MB/ sec (DVD-ROM) data transfer rates.

Characteristics:

  • Media Data Transfer Rate: CD-ROM=3600 KB/sec (max), DVD-ROM=10.3MB/sec (max)
  • Interface: IDE/ATAPI
  • Avg. Random Access Time: CD-ROM=95ms(typical), DVD-ROM=150ms (typical)
  • Buffer Memory: 256KB
  • Media capacity: CD-ROM=650MB, DVD-ROM= 4.7 GB(single sided)/9.4 GB(double-sided)
  • Multisession capable (Reads CD/R and CD-R/W media)
  • 12.7mm Slimline form factor
  • Operates in either vertical or horizontal positions
  • Interface supports standard and extended XA formats
  • Loading tray supports 12cm and 8cm disks

Limitations: DVD video is not supported.

  • Attributes provided: 8X/24X(max) IDE DVD-ROM Drive
  • Attributes required: One Slimline media bay
  • For 9405-520: (#2640)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later, AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#2742) - PCI Two-Line WAN IOA

#2742 is a WAN IOA that supports up to two multiple protocol communications (RVX) ports when one or two of the following cables are attached:

  • #0348 - V.24/EIA232 20-Ft PCI Cable
  • #0349 - V.24/EIA232 50-Ft PCI Cable (support only, not orderable)
  • #0353 - V.35 20-Ft PCI Cable
  • #0354 - V.35 50-Ft PCI Cable
  • #0355 - V.35 80-Ft PCI Cable (support only, not orderable)
  • #0356 - V.36 20-Ft PCI Cable
  • #0358 - V.36 80-Ft PCI Cable (support only, not orderable)
  • #0359 - X.21 20-Ft PCI Cable
  • #0360 - X.21 50-Ft PCI Cable
  • #0365 - V.24/EIA232 80-Ft PCI Cable
  • #0367 - Operations Console PCI Cable

Note: The #0367 cable ships with a 25 pin to 9 pin adapter.

  • Multiple #0367 cables may be ordered (but only one per #2742) to serve as consoles for secondary partitions when Logical Partitioning is utilized.

When #2742 is selected to support ECS, one of following cables must be specified:

  • #0348 V.24/EIA232 20-Ft PCI Cable
  • #0349 V.24/EIA232 50-Ft PCI Cable (support only, not orderable)
  • #0365 V.24/EIA232 80-Ft PCI Cable

#2742 does not support remote power-on.

  • Attributes provided: two RVX comm ports
  • Attributes required: one 3v PCI/PCI-X slot
  • For 9405-520: (#2742)
    • Minimum required: 0
    • Maximum allowed: 88 (Initial order maximum: 88)
    • OS level required: i5/OS V5R2, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#2744) - PCI 100Mbps Token-Ring IOA

(No longer available as of June 01, 2006)

The PCI 100Mbps Token-Ring IOA provides a single attachment to a 100Mbps, 16Mbps, or 4Mbps Token-Ring network. The feature consists of an IOA card, internal code that supplies IEEE 802.5 Media Access Control (MAC) and IEEE 802.2 Logical Link Control (LLC) functions. This IOA operates in half-or full-duplex mode.

A 2.44 meter (8-ft) token-ring cable is included with this feature. As an alternative, you can attach a separately priced twisted-pair cable to the RJ45 connection on the IOA. IBM Cabling System patch cables, included with this feature, can increase the length as required.

Prerequisites: If #2744 is used on an integrated xSeries server, one #0223 (100Mbps Token-Ring Specify) is required for each #2744.

  • For 9405-520: (#2744)
    • Minimum required: 0
    • Maximum allowed: 34 (Initial order maximum: 34)
    • OS level required: i5/OS V4R5, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#2749) - PCI Ultra Mag Media Ctlr

(No longer available as of March 15, 2005)

#2749 provides Ultra SCSI attachment capability for an external tape device or an external optical device.

  • For 9405-520: (#2749)
    • Minimum required: 0
    • Maximum allowed: 57 (Initial order maximum: 0)
    • OS level required: i5/OS V4R5, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#2757) - PCI-X Ultra RAID Disk Ctrl

(No longer available as of June 01, 2006)

This feature is a PCI-X SCSI controller with a maximum compressed write cache of 757MB. The #2757 provides RAID-5 protection for internal disks and also supports internal tape units, internal CD/ DVD-ROM and internal DVD-RAM units.

The #2757 has four LVD SCSI buses that support up to 20 internal disk units.

Hardware data compression is not supported.

In addition to providing RAID-5 protection for disks, the #2757 is also a high-performance controller for disks protected by system mirroring or disks with no data protection.

A minimum of three disk units of the same capacity are needed for a valid RAID-5 configuration. A maximum of six arrays are allowed per controller, with a maximum of 18 disk units allowed per array. All disk units in an array must be of the same capacity.

Parity is spread across either two, four, eight, or sixteen disk units in an array. If an array of three disk units is started, parity is spread across two disk units. If an array of four to seven disk units is started, parity is spread across four disk units. If an array of eight to fifteen disk units is started, parity is spread across eight disk units. If an array of sixteen to eighteen disk units is started, parity is spread across sixteen disk units.

The number of arrays and size of each array can be influenced by specifying an optimization of either balance, performance, or capacity in Operations Navigator when starting arrays. An optimization of balance is the default when starting arrays from the green screens. If disk units are included into an existing array, parity may be spread across less than the preferred number of disk units. In this case the RAID function must be stopped and started to redistribute the parity.

The #2757 can also control up to two internal removable media devices (tape, CD-ROM, DVD-ROM/RAM).

  • Attributes provided: Controller for up to 20 disk units and two internal removable media devices
  • Attributes required: One 3V PCI slot. This feature is only orderable as part of a feature conversion to #5581.
  • For 9405-520: (#2757)
    • Minimum required: 0
    • Maximum allowed: 24 (Initial order maximum: 24)
    • OS level required: i5/OS V5R2, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

    #2757 can not be installed in the model 520 CEC.

(#2772) - PCI Dual WAN/Modem IOA

(No longer available as of June 01, 2006)

The #2772 is a two-line WAN adapter, with two ports (RJ11), supports V.90 56K Async PPP and fax applications at data rates up to 14.4K via internal modems. Connection to the V.90 ports is via telephone cable.

Remote ring-indicator is not supported.

#2772 is non-CIM (Complex Impedance Matching).

A minimum of one modem cable must be ordered for each #2772. All modem cables installed on a system must be the same feature number.

  • #1010 Modem Cable - Austria
  • #1011 Modem Cable - Belgium
  • #1012 Modem Cable - Africa
  • #1013 Modem Cable - Israel
  • #1014 Modem Cable - Italy
  • #1015 Modem Cable - France
  • #1016 Modem Cable - Germany
  • #1017 Modem Cable - UK
  • #1018 Modem Cable - Iceland/Sweden
  • #1020 Modem Cable - HK/NZ
  • #1021 Modem Cable - Fin/Nor
  • #1022 Modem Cable - Netherlands
  • #1023 Modem Cable - Swiss
  • #1024 Modem Cable - Denmark
  • #1025 Modem Cable - US/Canada

#2772 has country specific usage.

  • Attributes provided: Two WAN/modem ports
  • Attributes required: One 3V or 5V PCI slot (either short or long)
  • For 9405-520: (#2772)
    • Minimum required: 0
    • Maximum allowed: 88 (Initial order maximum: 88)
    • OS level required: i5/OS V5R1, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#2780) - PCI-X Ultra4 RAID Disk Ctrl

(No longer available as of May 01, 2008)

The #2780 is an Ultra4 (Ultra320) SCSI controller with a maximum compressed write cache of 757MB and a maximum compressed read cache size of 1GB, that provides RAID-5 protection for internal disks and also supports internal tape units, CD-ROM and DVD units. The #2780 has four Ultra4(Ultra320) SCSI buses.

In addition to providing RAID-5 protection for disks, #2780 is also designed to work as a high performance controller for disks protected by system mirroring or disks with no protection.

This controller also uses a Cache Battery Pack with can be replaced concurrent with system operation.

The #2780 controller supports a maximum of 20 disk units.

A minimum of three disk units of the same capacity are needed for a valid RAID-5 configuration. A maximum of six arrays are allowed per controller, with a maximum of 18 disk units allowed per array. All disk units in an array must be of the same capacity.

Parity is spread across either two, four, eight, or 16 disk units in an array. If an array of three disk units is started, parity is spread across two disk units. If an array of four to seven disk units is started, parity is spread across four disk units. If an array of 8-15 disk units is started, parity is spread across eight disk units. If an array of 16-18 disk units is started, parity is spread across 16 disk units.

The number of arrays and size of each array can be influenced by specifying an optimization of either "Balance", "Performance", or "Capacity" in Operations Navigator when starting arrays. An optimization of "Balance" will be used by default when starting arrays from the green screens. If disk units are included into an existing array, the number of parity drives does not increase, so parity may be spread across less than the preferred number of disk units. In this case the RAID function must be stopped and then started in order to redistribute the parity.

Note: This controller does not support DASD compression.

  • Attributes provided: SCSI Raid Controller
  • Attributes required: One 3V long PCI slot
  • For 9405-520: (#2780)
    • Minimum required: 0
    • Maximum allowed: 24 (Initial order maximum: 24)
    • OS level required: i5/OS V5R2, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

    #2780 can not be installed in the model 520 CEC.

(#2787) - PCI-X Fibre Chan Disk Ctlr

(No longer available as of June 01, 2006)

Provides Fibre Channel attachment for external disk devices. #2787 supports point-to-point and arbitrated loop topologies and has an LC type cable connector. Each #2787 is shipped with a wrap connector (P/N 05N6767). This feature supports 64bit, 133MHz PCI-X bus speeds. #0626 is a Linux direct attach version of this adapter.

One of the following adapter kits is required when connecting SC type cables to the #2787:

  • #0371 -- LC-SC Adapter Kit (50um) can be ordered, both on initial, model upgrades, and simple MES orders. This optional kit is used to attach SC-type 50 micron fiber cables to a #2787. This kit contains a 2m LC-ST cable and ST-SC adapter for 50 micron fibre cables.

  • #0372 - LC-SC Adapter Kit (62.5um) can be ordered, both on initial, model upgrades, and simple MES orders. This optional kit is used to attach SC-type 62.5 micron fiber cables to a #2787. This kit contains a 2m LC-ST cable and ST-SC adapter for 62.5 micron fibre cables.

An optics cleaning kit and instruction sheet is shipped with the #2787. The customer must supply all Fibre Channel cables for this controller.

  • Attributes provided: Fiber attachment of external DASD
  • Attributes required: One PCI slot
  • For 9405-520: (#2787)
    • Minimum required: 0
    • Maximum allowed: 37 (Initial order maximum: 0)
    • OS level required: i5/OS V5R2, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#2793) - PCI 2-Line WAN w/Modem

The #2793 is a 2-line/port WAN w/modem adapter. This feature is the non-CIM (Complex Impedance Matching) version offered in all countries except Australia and New Zealand.

Port 0 is the modem port and supports V.92 56K Async PPP, V.92 data modem, V.44 data compression, V.34 FAX modem and FAX functions, such as ECM and 2D/1D conversion. Port 0 does not provide Sync modem capabilities (SDLC and Sync PPP).

Port 1 is the RVX port and supports multiple communications protocols, including synchronous operations.

Select one of the following cables to attach to port 0(modem port):

  • #1010 Modem Cable - Austria
  • #1011 Modem Cable - Belgium
  • #1012 Modem Cable - Africa
  • #1013 Modem Cable - Israel
  • #1014 Modem Cable - Italy
  • #1015 Modem Cable - France
  • #1016 Modem Cable - Germany
  • #1017 Modem Cable - UK
  • #1018 Modem Cable - Iceland/Sweden
  • #1020 Modem Cable - HK/NZ
  • #1021 Modem Cable - Fin/Nor
  • #1022 Modem Cable - Netherlands
  • #1023 Modem Cable - Swiss
  • #1024 Modem Cable - Denmark
  • #1025 Modem Cable - US/Canada

Select one of the following cables to attach to port 1(RVX port):

  • #0348 - V.24/EIA232 20-Ft PCI Cable
  • #0353 - V.35 20-Ft PCI Cable
  • #0356 - V.36 20-Ft PCI Cable
  • #0359 - X.21 20-Ft PCI Cable
  • #0367 - Operations Console PCI Cable (ships with a 25 pin to 9 pin adapter)
    • Multiple #0367 cables can be ordered but only one per #2793) to serve as consoles for secondary partitions when Logical Partitioning is utilized.

ECS is supported from both the modem port, and the RVX port. The following cable is required to support ECS from the RVX port:

  • #0348 - V.24/EIA232 20-Ft PCI Cable

The #2793 does not support the remote ring indicate function.

  • Attributes provided: One RVX port and one integrated modem port
  • Attributes required: One PCI slot (3 volt)
  • For 9405-520: (#2793)
    • Minimum required: 0
    • Maximum allowed: 69 (Initial order maximum: 69)
    • OS level required: i5/OS V5R2, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#2805) - PCI Quad Modem IOA

(No Longer Available as of April 29, 2011)

The #2805 is a four-line WAN modem adapter, with four RJ-11 ports, supports V.92 56K Async SLIP/PPP and V.34 Fax applications at data rates up to 33.6K via integrated modems. Connection to the V.92 ports is via telephone cable. The V.92 functions offer increased upload throughput, improved V.44 data compression, and shortened modem synchronization periods.

The call waiting and modem on hold functions associated with V.92 are not supported.

Remote power on via ring-indicator and SDLC are not supported.

#2805 is non-CIM (Complex Impedance Matching)

A minimum of one modem cable must be ordered for each #2805. All modem cables installed on a system must be the same feature number.

  • #1010 Modem Cable - Austria
  • #1011 Modem Cable - Belgium
  • #1012 Modem Cable - Africa
  • #1013 Modem Cable - Israel
  • #1014 Modem Cable - Italy
  • #1015 Modem Cable - France
  • #1016 Modem Cable - Germany
  • #1017 Modem Cable - UK
  • #1018 Modem Cable - Iceland/Sweden
  • #1020 Modem Cable - HK/NZ
  • #1021 Modem Cable - Fin/Nor
  • #1022 Modem Cable - Netherlands
  • #1023 Modem Cable - Swiss
  • #1024 Modem Cable - Denmark
  • #1025 Modem Cable - US/Canada
  • Attributes provided: four WAN ports
  • Attributes required: one PCI slot
  • For 9405-520: (#2805)
    • Minimum required: 0
    • Maximum allowed: 88 (Initial order maximum: 88)
    • OS level required: i5/OS V5R1, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#2844) - PCI IOP

(No Longer Available as of November 26, 2010)

#2844 is a PCI I/O processor that drives PCI IOA adapters in a POWER5 or earlier system unit and in HSL attached PCI or PCI-X I/O expansion towers/units.

A #2844 can drive a maximum of four IOAs, subject to configuration restrictions.

  • Attributes provided: Support for up to four PCI adapters
  • Attributes required: One 3V PCI slot (either short or long)
  • For 9405-520: (#2844)
    • Minimum required: 0
    • Maximum allowed: 37 (Initial order maximum: 37)
    • OS level required: i5/OS V5R2, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#2847) - PCI IOP for SAN Load Source

(No Longer Available as of November 26, 2010)

Provides the specialized function required to attach i5/OS load source via an IOP-based Fibre Channel adapter and boot from that load source. #2847 PCI IOP for SAN Load Source does not support multipath for the i5/OS load source disk unit, but does support multipath for all other logical units (LUNs) attached to this IOP. A minimum of two IOPs are required for enabling redundancy. See the Redbook, "iSeries and TotalStorage: A Guide to Implementing external disk on IBM eServer i5 -SG24-7120", for more information.

  • Attributes required: #0531 V5R3M5 Machine Code
  • For 9405-520: (#2847)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 0)
    • OS level required: i5/OS V5R3 with V5R3M5 Machine Code, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#2849) - PCI 100/10Mbps Ethernet IOA

(No longer available as of June 01, 2006)

The #2849 allows attachment to standardized 100Mbps high-speed Ethernet LANs and allows attachment to existing 10Mbps Ethernet LANs. This adapter comes with an RJ45 connector for attachment to UTP-5 media.

The #2849 is not supported on/with any Integrated Netfinity Server feature.

  • Attributes provided: Attachment to 100/10Mbps Ethernet LANs
  • Attributes required: One PCI slot (3v or 5v)
  • For 9405-520: (#2849)
    • Minimum required: 0
    • Maximum allowed: 34 (Initial order maximum: 34)
    • OS level required: i5/OS V5R2, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#2863) - 4-Port X.21 Cable

(No longer available as of June 23, 2006)

The #2863 4-port X.21 Cable provides 4 ports of X.21 connectivity for the #2947 PCI Multiprotocol Adapter.

  • Attributes provided: 4-port X.21 cable for #2947
  • Attributes required: One #2947 adapter
  • For 9405-520: (#2863)
    • Minimum required: 0
    • Maximum allowed: 4 (Initial order maximum: 4)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#2864) - 4-Port V.35 DTE Cable

(No longer available as of June 23, 2006)

The #2864 4-port DTE Cable provides 4 ports of DTE connectivity for the #2947 PCI Multiprotocol Adapter.

  • Attributes provided: 4-port X.35 (DTE) cable for #2947
  • Attributes required: One #2947 adapter
  • For 9405-520: (#2864)
    • Minimum required: 0
    • Maximum allowed: 4 (Initial order maximum: 4)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#2877) - 4-Position Int Bus Cable

(No Longer Available as of November 26, 2010)

This cable provides the capability to interconnect adapters that provide H.100 bus connectors. This 4-position cable should be used when four or less adapters with H.100 connectors will be interconnected. When more than 4 and less than or equal to 8 adapters will be connected, the H-100 Bus 8-position Cable (#4353) should be used.

  • Attributes provided: H.100 bus connection between adapters
  • Attributes required: Two to Four H.100 adapters
  • For 9405-520: (#2877)
    • Minimum required: 0
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later,
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#2888) - HSL-2/RIO-G Ports - 2 Copper

(No Longer Available as of November 27, 2009)

Provides an HSL-2/RIO-2 adapter that is installed in the system unit. It provides two ports for attaching one HSL-2 loop for external connectivity of I/O expansion drawers and towers. The #2888 is inserted in the GX slot and does not take a PCI slot.

  • Attributes provided: Two copper HSL-2 ports
  • Attributes required: GX slot
  • For 9405-520: (#2888)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: I5/OS V5R3 with V5R3M5 Machine Code, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#2917) - English U/L DBCS

All systems require a #29XX specify code. A 29XX code is required on all model upgrades, even if one is already on the records.

Machine history at the IBM plant is used to ship the proper language when the 29XX code is not on an MES order.

These features have country-specific usage.

  • For 9405-520: (#2917)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V3R7, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#2924) - English

All systems require a #29XX specify code. A 29XX code is required on all model upgrades, even if one is already on the records.

Machine history at the IBM plant is used to ship the proper language when the 29XX code is not on an MES order.

These features have country-specific usage.

  • For 9405-520: (#2924)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V1R1, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#2934) - ASYNC Terminal/Prt Cable

The Asynchronous Printer/Terminal Cable is used for attaching printers, plotters, and terminals that support the EIA-232 standard to any asynchronous adapter. This cable is the equivalent of the combination of FC 2936 (modem cable) and FC 2937 (printer/terminal interposer) and replaces this method of printer/terminal attachment. p.This cable is 3m (9.8 feet) long, uses DB25 connectors and is supported on all RS/6000 systems using any asynchronous ports. It is is used in conjunction with :

  • FC 2931 (8-port Async Adapter EIA232, ISA bus)
  • FC 8133 (RJ45-DB25 converter cable for 16-port RANs 8130, 8134, 8136)
  • Attributes provided: EIA232 device attachment capability
  • Attributes required: Any RS/6000 Asynchronous port
  • For 9405-520: (#2934)
    • Minimum required: 0
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#2936) - ASYNC Modem Cable

Used to attach a modem to the standard I/O ports with the 10-pin to 25-pin converter cable (#3925), 8-port Cable Assembly, 16-Port Cable Assembly, 16-Port Asynchronous Concentrator (with RJ-45 to DB-25 Converter Cable feature #6402) or the 16-Port EIA-232 Remote Async Node (with RJ45 to DB25 Converter Cable feature #8133). The cable is 3 meters (9.8 feet) in length.

  • Attributes provided: Modem attachment to async or serial port
  • Attributes required: Async or serial port
  • For 9405-520: (#2936)
    • Minimum required: 0
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#2943) - 8-Port ASYNC Adapter

(No Longer Available as of November 27, 2009)

For connection of up to 8 asynchronous EIA-232 or RS-422 devices. All eight ports are software programmable to support either EIA-232E or RS-422A protocols, at up to 230K baud.

  • Attributes provided: 8 Async ports
  • Attributes required: One PCI slot, #0140 (Logical Partitioning Specify and (#0142 (LINUX Partition Specify) or #0145 (AIX Partition Specify))
  • For 9405-520: (#2943)
    • Minimum required: 0
    • Maximum allowed: 10 (Initial order maximum: 10)
    • OS level required: AIX 5L for Power V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#2947) - PCI Multiprotocol Adapter

(No longer available as of June 23, 2006)

The IBM ARTIC960Hx 4-Port Selectable PCI Adapter (#2947) is a one- slot, standard length, 32-bit PCI card. The adapter provides 4-Ports of: EIA-232, EIA530, RS-449, X.21, or V.35. Each port will support speeds of up 2.0M bps. Software support is provided by ARTIC960 Support for AIX, Developer's Kit, AIX Versions 4.2.1 or 4.3.2 or later that provide SDLC and Bisync support; AIX Versions 4.1.5, 4.2.1, 4.3.1 or later that provide AIXLink X.25 LPP Version 1.1.5 support.

Note: This adapter may have AIX 5.1 support limitations. To view the latest AIX 5.1 support limitation statements, visit:

http://www.ibm.com/servers/aix/os/adapters/51.html
  • Attributes provided: One to four WAN connections at up to 2.0Mbps
  • Attributes required: One full length 32-bit PCI slot, AIX Version 4.2.1 or 4.3.2 or later (for SDLC or Bisync support); AIX Version 4.1.5, 4.2.1, 4.3.1 or later (for AIXLink X.25 LPP Version 1.1.5 support).
  • For 9405-520: (#2947)
    • Minimum required: 0
    • Maximum allowed: 4 (Initial order maximum: 4)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#2951) - V.24/EIA 232 Cable

(No longer available as of December 01, 2005)

V.24 cable for use with #0635 - SDLC/X.25 - 2-port Adapter. Maximum of two cables per #0635.

  • Attributes provided: V.24 connectivity to #0635
  • Attributes required: #0635 SDLC/X.25 - 2-port Adapter
  • For 9405-520: (#2951)
    • Minimum required: 0
    • Maximum allowed: 20 (Initial order maximum: 20)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later,
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#2952) - V.35 Cable

(No longer available as of December 01, 2005)

V.35 cable for use with #0635 - SDLC/X.25 - 2-port Adapter. Maximum of two cables per #0635.

  • Attributes provided: V.35 connectivity to #0635
  • Attributes required: #0635 - SDLC/X.25 - 2-port Adapter
  • For 9405-520: (#2952)
    • Minimum required: 0
    • Maximum allowed: 20 (Initial order maximum: 20)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later,
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#2953) - V.36 Cable

(No longer available as of December 01, 2005)

V.36/EIA-499 cable for use with #0635 - SDLC/X.25 - 2-port Adapter. Maximum of two cables per #0635.

  • Attributes provided: V.36/EIA-499 connectivity to #0635
  • Attributes required: #0635 - SDLC/X.25 - 2-port Adapter
  • For 9405-520: (#2953)
    • Minimum required: 0
    • Maximum allowed: 20 (Initial order maximum: 20)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later,
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#2954) - X.21 Cable

(No longer available as of December 01, 2005)

X.21 cable for use with #0635 - SDLC/X.25 - 2-port Adapter. Maximum of two cables per #0635.

  • Attributes provided: x.21 connectivity to #0635
  • Attributes required: #0635 - SDLC/X.25 - 2-port Adapter
  • For 9405-520: (#2954)
    • Minimum required: 0
    • Maximum allowed: 20 (Initial order maximum: 20)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later,
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#2958) - Universal Japanese

All systems require a #29XX specify code. A 29XX code is required on all model upgrades, even if one is already on the records.

Machine history at the IBM plant is used to ship the proper language when the 29XX code is not on an MES order.

These features have country-specific usage.

  • For 9405-520: (#2958)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R4, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#3578) - 300GB 10K rpm Disk Unit

(No longer available as of May 08, 2007)

Provides a 10,000 rpm disk unit with 300GB of storage capacity and an industry standard Ultra3 SCSI interface speed of up to 160MBps.

  • Attributes provided: 300GB disk unit.
  • Attributes required: One disk drive bay.
  • For 9405-520: (#3578)
    • Minimum required: 0
    • Maximum allowed: 130 (Initial order maximum: 0)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#3585) - 300GB 15k rpm Disk Unit

(No longer available as of February 01, 2009)

The 300GB 15k RPM Ultra320 SCSI Disk Drive Assembly provides 300GB of storage capacity utilizing new vertical recording technology and supports the industry standard Ultra3 SCSI interface speed of up to 320 MBps.

Characteristics:

  • Form Factor: 3.5-inch, 1-inch (25 mm) high
  • Cable included: No
  • External Interface: Ultra320 SCSI (16-bit, Low Voltage Differential)
  • Attachment Industry Spec: SCSI U320
  • Average Seek Time: 3.7 ms (based on four reads to one write)
  • Average Latency: 2 ms
  • Rotational Speed: 15,000 RPM
  • Maximum Data Transfer Rate: 107 MBps

Limitation: This disk drive requires attachment to a supported Ultra320 SCSI Adapter in a system that supports an Ultra320 SCSI cable/ backplane in order for the drive to run at 320 MBps. Also, any and all other SCSI devices on the same SCSI bus must also be Ultra2, Ultra3, or Ultra320 SCSI device(s) in order for this disk drive to run at 320 MBps.

  • Attributes provided: 300GB SCSI Disk Drive
  • Attributes required: Disk Bay (except EXP 24 bays)
  • For 9405-520: (#3585)
    • Minimum required: 0
    • Maximum allowed: 130 (Initial order maximum: 0)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#3637) - T541H/L150P TFT Color Monito

(No longer available as of May 02, 2006)

Both the T541H and L150p monitors have the following general characteristics:

  • Business Black color
  • 15-inch TFT LCD digital screen with a viewable image size of 381 mm 15.0 inches) measured diagonally, incorporating a 0.297 mm pixel pitch/type for bright, high-definition images.
  • Designed to provide flicker free operation at a maximum resolution of 1024 x 768 pels at 75Hz in analog mode and 1024 x 768 pels at 60Hz in digital mode.
  • Tilt/swivel stand
  • Supports 2D Graphics Adapters only
  • Attributes provided: Color Flat-panel Monitor
  • Attributes required: 2D Graphics Adapter
  • For 9405-520: (#3637)
    • Minimum required: 0
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#3638) - C220P 21" Color Monitor

(No longer available as of July 15, 2005)

The IBM C220p monitor has the following general characteristics:

  • Business black color
  • 21.0-inch Flat Aperture Grille CRT with a viewable image size of 508 mm (20.0 inches) measured diagonally, incorporating a 0.248 mm pixel pitch for bright, high-definition images.
  • Designed to provide reduced flicker operation at an optimum and maximum supported addressability of 1600 x 1200 pels at up to 85 Hz Vesa)non-interlaced. Capable of 2048 x 1636 at 75 Hz (Vesa).
  • Tilt/swivel stand
  • Dual input allows attachment to two systems concurrently.
  • Depth: 483.6 mm (19.0 in.)
  • Height: 516.4 mm (20.3 in.)
  • Width: 512.8 mm (20.2 in.)
  • Weight: 30.5 kg (67.2 lbs.)
  • Attributes provided: Color Monitor
  • Attributes required: Graphics Adapter
  • For 9405-520: (#3638)
    • Minimum required: 0
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#3639) - L180P TFT 17" Color Display

(No longer available as of December 01, 2005)

The IBM ThinkVision L180p flat-panel monitor has the following general characteristics:

  • Business black color
  • 17.0-inch LCD digital screen with a viewable image size of 432 mm 17.0 inches) measured diagonally, incorporating a 0.264mm pixel pitch/type for bright, high-definition images.
  • Maximum resolution of 1280 x 1024.
  • Tilt/swivel and height adjustable stand
  • Analog or digital connection
  • Dual input allows attachment to two systems concurrently
  • Depth: 237.0 mm (9.3 in.)
  • Height: 457.0 mm (19.0 in.)
  • Width: 400.0 mm (15.7 in.)
  • Weight: 5.7 kg (12.6 lbs.)
  • Viewing angle: Vertical 170 degrees; horizontal 170 degrees
  • Contrast ration: 500:1(typical)
  • Video inputs: 15-pin D/DVI-D
  • Two removable cables: one analog and one digital
  • Attributes provided: Color Flat-panel Monitor
  • Attributes required: Graphics Adapter
  • For 9405-520: (#3639)
    • Minimum required: 0
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#3640) - L171P TFT 17" Black Display

(No longer available as of May 02, 2006)

  • Attributes provided: Color Flat-panel Monitor
  • Attributes required: Graphics Adapter
  • For 9405-520: (#3640)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: 0)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE Linux Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#3641) - T115 TFT 15" Color Display

(No longer available as of July 13, 2007)

The IBM T115 LCD flat-panel monitor has the following general characteristics:

  • Business black color
  • 15.0-inch LCD digital screen with a viewable image size of 381 mm (15.0 inches) measured diagonally, incorporating a 0.297mm pixel pitch/type for bright, high-definition images.
  • Maximum resolution of 1024 x 768 (XGA)
  • Tilt adjustable stand
  • Analog connection
  • Internal power
  • Depth (w/stand): 144 mm (6.67 inches)
  • Height (max w/stand): 361 mm (14.2 inches
  • Width: 362 mm (14.2 inches)
  • Weight: 2.9 kg (6.4 lbs)
  • Contrast ratio: 400:1 (typical)
  • Brightness: 250cd/m2 (typical)
  • Viewing angles (H/V): 130 degrees/100 degrees
  • Attributes provided: Color Flat-panel Monitor
  • Attributes required: Graphics Adapter
  • For 9405-520: (#3641)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 0)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 4, or later, SUSE Linux Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#3643) - T120 TFT 20" Color Display

(No longer available as of January 12, 2008)

The IBM T120 LCD flat-panel monitor has the following general characteristics:

  • Business black color
  • 20.1-inch LCD digital screen with a viewable image size of 511 mm (20.1 inches) measured diagonally, incorporating a 0.255 mm pixel pitch/type for bright, high-definition images.
  • Maximum resolution of 1600 x 1200 (UXGA)
  • Tilt/lift adjustable stand
  • Analog and digital connections
  • Internal power
  • Depth (w/stand): 246 mm (9.7 inches)
  • Height (max w/stand): 416.6 mm (16.5 inches)
  • Width: 445.6 mm (17.5 inches)
  • Weight: 7.5 kg (16.5 lbs)
  • Contrast ratio: 700:1 (typical)
  • Brightness:300cd/m2 (typical)
  • Viewing angles(H/V): 178 degrees/178 degrees
  • Video inputs: 15-pin D / DVI-D
  • Two removable cables, one analog and one digital
  • Attributes provided: Color Flat-panel Monitor
  • Attributes required: Graphics Adapter
  • For 9405-520: (#3643)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 0)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 4, or later, SUSE Linux Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#3644) - T119 TFT 19" Color Display

(No Longer Available as of July 28, 2009)

The IBM T119 LCD flat-panel monitor has the following general characteristics:

  • Business black color
  • 19.0-inch LCD digital screen with a viewable image size of 483 mm (19.0 inches) measured diagonally, incorporating a 0.294 mm pixel pitch/type for bright, high-definition images.
  • Maximum resolution of 1280 x 1024 (SXGA)
  • Tilt/lift adjustable stand
  • Analog and digital connections
  • Internal power
  • Depth (w/stand): 246 mm (9.7 inches)
  • Height (max w/stand): 443.6 mm (17.5 inches)
  • Width: 418 mm (16.5 inches)
  • Weight: 7.4 kg (16.3 lbs)
  • Contrast ratio: 550:1 (typical)
  • Brightness:250cd/m2 (typical)
  • Viewing angles (H/V): 140 degrees/135 degrees
  • Video inputs: 15-pin D / DVI-D
  • Two removable cables, one analog and one digital
  • Attributes provided: Color Flat-panel Monitor
  • Attributes required: Graphics Adapter
  • For 9405-520: (#3644)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 0)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 4, or later, SUSE Linux Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#3645) - T117 TFT 17" Color Display

(No Longer Available as of July 28, 2009)

The IBM T117 LCD flat-panel monitor has the following general characteristics:

  • Business black color
  • 17.0-inch LCD digital screen with a viewable image size of 432 mm (17.0 inches) measured diagonally, incorporating a 0.264 mm pixel pitch/type for bright, high-definition images.
  • Maximum resolution of 1280 x 1024 (SXGA)
  • Tilt/lift adjustable stand
  • Analog and digital connections
  • Internal power
  • Depth (w/stand): 246 mm (9.7 inches)
  • Height (max w/stand): 395.5 mm (15.6 inches)
  • Width: 375.4 mm (14.8 inches)
  • Weight: 5.8 kg (12.8 lbs)
  • Contrast ratio: 500:1 (typical)
  • Brightness: 300cd/m2 (typical)
  • Viewing angles (H/V): 140 degrees/130 degrees
  • Video inputs: 15-pin D / DVI-D
  • Two removable cables, one analog and one digital
  • Attributes provided: Color Flat-panel Monitor
  • Attributes required: Graphics Adapter
  • For 9405-520: (#3645)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 0)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 4, or later, SUSE Linux Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#3658) - 428.43GB 15k rpm SAS Disk Dr

(No Longer Available as of February 8, 2013)

Attached SAS DASD device, in a carrier capable of providing Hot Swap support. Provides 428GB of storage capacity. Supports the industry standard SAS interface. Can be used only in a drawer/system designed to support the SAS interface.

Characteristics:

  • Form Factor: 3.5 inch Form Factor, 1 inch drive.
  • Cable included: No
  • External Interface: standard SAS Dual Port
  • Rotational Speed: 15,000 RPM
  • Interface Speed: 300 MB/sec.
  • Format: 528 Bytes/sector default, 512 B
  • Attributes provided: 428.43GB SAS DASD, 15K RPM, 3.5"
  • Attributes required: Open SAS DASD slot
  • For 9405-520: (#3658)
    • Minimum required: 0
    • Maximum allowed: 278 (Initial order maximum: 0)
    • OS level required: IBM i 6.1, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#3677) - 139.5GB 15k rpm SAS Disk Drv

(No Longer Available as of February 8, 2013)

Provides a 15,000 RPM, 3.5-inch disk unit with 139.5GB capacity and a Serially Attached SCSI (SAS) interface. #3677 is mounted in a carrier and hot swap is supported.

Note: This drive is not supported as a load source drive for POWER5/POWER5+ systems.

  • Attributes provided: 139.5GB Disk Unit
  • Attributes required: Disk Unit Slot and SAS Disk Unit Controller
  • For 9405-520: (#3677)
    • Minimum required: 0
    • Maximum allowed: 278 (Initial order maximum: 0)
    • OS level required: IBM i 5.4 with V5R4M5 SLIC, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#3678) - 283.7GB 15k rpm SAS Disk Drv

(No Longer Available as of February 8, 2013)

Provides a 15,000 RPM, 3.5-inch disk unit with 283.7GB capacity and a Serially Attached SCSI (SAS) interface. #3678 is mounted in a carrier and hot swap is supported.

Note: This drive is not supported as a load source drive for POWER5/POWER5+ systems.

  • Attributes provided: 283.7GB Disk Unit
  • Attributes required: Disk Unit Slot and a SAS Disk Unit Controller
  • For 9405-520: (#3678)
    • Minimum required: 0
    • Maximum allowed: 278 (Initial order maximum: 0)
    • OS level required: IBM i 5.4 with V5R4M5 SLIC, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#3691) - SAS Cbl (YO) 1X Adp-Enc 1.5M

This SAS cable (YO) connects a remote SAS drawer to a SAS controller adapter. This cable supports single controller/dual path attach between the SAS controller adapter and the SAS disk drawer. This cable has one Mini SAS 4X plug connector on the adapter end keyed for an END DEVICE, wired in 4x mode and two Mini SAS 4X plug connectors on the drawer end keyed for ENCLOSURE DOWN Arrow, both are wired in 2x mode. Follow the directions on the connector labels when attaching the connectors on this cable. This cable is 1.5 meters long, choose the SAS (YO) cable length that matches the distance between the adapter and the SAS disk drawer.

  • Attributes provided: Connection between SAS controller adapter and a SAS disk drawer
  • Attributes required: SAS controller adapter and a SAS disk drawer
  • For 9405-520: (#3691)
    • Minimum required: 0
    • (Initial order maximum: 0)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#3692) - SAS Cable (YO) 1X Adp-Enc 3M

This SAS cable (YO) connects a remote SAS drawer to a SAS controller adapter. This cable supports single controller/dual path attach between the SAS controller adapter and the SAS disk drawer. This cable has one Mini SAS 4X plug connector on the adapter end keyed for an END DEVICE, wired in 4x mode and two Mini SAS 4X plug connectors on the drawer end keyed for ENCLOSURE DOWN Arrow, both are wired in 2x mode. Follow the directions on the connector labels when attaching the connectors on this cable. This cable is 3 meters long, choose the SAS (YO) cable length that matches the distance between the adapter and the SAS disk drawer.

  • Attributes provided: Connection between SAS controller adapter and a SAS disk drawer
  • Attributes required: SAS controller adapter and a SAS disk drawer
  • For 9405-520: (#3692)
    • Minimum required: 0
    • (Initial order maximum: 0)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#3693) - SAS Cable (YO) 1X Adp-Enc 6M

This SAS cable (YO) connects a remote SAS drawer to a SAS controller adapter. This cable supports single controller/dual path attach between the SAS controller adapter and the SAS disk drawer. This cable has one Mini SAS 4X plug connector on the adapter end keyed for an END DEVICE, wired in 4x mode and two Mini SAS 4X plug connectors on the drawer end keyed for ENCLOSURE DOWN Arrow, both are wired in 2x mode. Follow the directions on the connector labels when attaching the connectors on this cable. This cable is 6 meters long, choose the SAS (YO) cable length that matches the distance between the adapter and the SAS disk drawer.

  • Attributes provided: Connection between SAS controller adapter and a SAS disk drawer
  • Attributes required: SAS controller adapter and a SAS disk drawer
  • For 9405-520: (#3693)
    • Minimum required: 0
    • (Initial order maximum: 0)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#3694) - SAS Cable (YO) 1X Adp-Enc 15M

This SAS cable (YO) connects a remote SAS drawer to a SAS controller adapter. This cable supports single controller/dual path attach between the SAS controller adapter and the SAS disk drawer. This cable has one Mini SAS 4X plug connector on the adapter end keyed for an END DEVICE, wired in 4x mode and two Mini SAS 4X plug connectors on the drawer end keyed for ENCLOSURE DOWN Arrow, both are wired in 2x mode. Follow the directions on the connector labels when attaching the connectors on this cable. This cable is 15 meters long, choose the SAS (YO) cable length that matches the distance between the adapter and the SAS disk drawer.

  • Attributes provided: Connection between SAS controller adapter and a SAS disk drawer
  • Attributes required: SAS controller adapter and a SAS disk drawer
  • For 9405-520: (#3694)
    • Minimum required: 0
    • (Initial order maximum: 0)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#4242) - 6-Ft Ext Cable for Display

This cable is required to connect displays with a 15-pin "D" shell connector to the appropriate accelerator connector when it is farther away than the attached monitor cable can reach. Rack mounted systems are likely candidates for this extender cable.

  • Attributes provided: 6-foot extension cable
  • Attributes required: Supported monitor and adapter with a 15-pin "D" shell connector.
  • For 9405-520: (#4242)
    • Minimum required: 0
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#4256) - Extender Cable for Keybd

This feature provides a 2M extension cable for use with USB keyboards.

  • Attributes provided: 2M Extension Cable
  • Attributes required: USB Keyboard
  • For 9405-520: (#4256)
    • Minimum required: 0
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#4263) - Direct Attach Tape Cables

(No Longer Available as of November 27, 2009)

The #4263 provides the required SCSI and power cables for installing a tape device in the half-high slot of a CEC.

  • Attributes provided: Power and data cabling
  • Attributes required: Tape device installing in half-high CEC slot.
  • For 9405-520: (#4263)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#4270) - Ctlr to External Port Cable

(No longer available as of December 01, 2006)

SCSI cable that connects one SCSI internal controller to an external port allowing attachment of external SCSI devices to the system. Installing this feature in the system will negate the usage of a second four-pack disk enclosure and blocks 1 PCI slot.

  • Attributes provided: External SCSI port
  • Attributes required: One internal SCSI controller and 1 PCI slot
  • For 9405-520: (#4270)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#4319) - 35.16GB 10k rpm Disk Unit

(No longer available as of January 04, 2008)

#4319 is a 10k rpm disk unit with 35.16GB capacity and an Ultra2 SCSI interface.

  • Attributes provided: 35.16GB disk unit
  • Attributes required: Disk unit slot and a disk unit controller
  • For 9405-520: (#4319)
    • Minimum required: 0
    • Maximum allowed: 278 (Initial order maximum: 149)
    • OS level required: i5/OS V5R1, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#4326) - 35.16GB 15k rpm Disk Unit

(No longer available as of May 01, 2007)

#4326 is a 15k rpm disk unit with 35.16GB capacity and a SCSI interface.

  • Attributes provided: 35.16GB disk unit
  • Attributes required: Disk unit slot and a disk unit controller
  • For 9405-520: (#4326)
    • Minimum required: 0
    • Maximum allowed: 278 (Initial order maximum: 149)
    • OS level required: i5/OS V5R2, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#4327) - 70.56GB 15k rpm Disk Unit

(No longer available as of February 01, 2009)

#4327 is a 15k rpm disk unit with 70.56GB capacity and an Ultra320 SCSI interface.

  • Attributes provided: 70.56GB disk unit
  • Attributes required: disk unit slot and a disk unit controller
  • For 9405-520: (#4327)
    • Minimum required: 0
    • Maximum allowed: 278 (Initial order maximum: 149)
    • OS level required: i5/OS V5R2, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#4328) - 141.12GB 15k rpm Disk Unit

Provides a 15,000 rpm disk unit with 141.12GB capacity and a Ultra-4 (Ultra320) SCSI interface.

  • Attributes provided: 141.12GB disk unit
  • Attributes required: Disk unit slot and disk unit controller
  • For 9405-520: (#4328)
    • Minimum required: 0
    • Maximum allowed: 278 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#4329) - 282.25GB 15k rpm Disk Unit

(No longer available as of February 01, 2009)

Provides a 15k rpm disk unit with 282.25GB capacity and an Ultra-4 (Ultra320) SCSI interface. This disk is physically identical to the #1269 disk drive, but the #4329 feature designates the drive is located in a #5094/5294/9094/8294/0595/5095 I/O expansion unit or in a 520/525/550/570 system unit.

Note: This drive is not supported as a load source drive with i5/OS V5R4 with machine code V5R4M5 or earlier.

  • Attributes provided: 282.25GB disk unit
  • Attributes required: Disk unit slot and disk unit controller
  • For 9405-520: (#4329)
    • Minimum required: 0
    • Maximum allowed: 139 (Initial order maximum: 0)
    • OS level required: i5/OS V5R4, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#4353) - 8-Position H.100 Bus Cable

(No longer available as of January 15, 2005)

This cable provides the capability to interconnect adapters that provide H.100 bus connectors. This 8-position cable should be used when more than four and less than or equal to eight adapters with H.100 connectors will be interconnected. If four or less adapters are interconnected, the 4-Position Int Bus Cable (#2877) should be used.

  • Attributes provided: H.100 bus connection between adapters
  • Attributes required: Four to eight H.100 adapters
  • For 9405-520: (#4353)
    • Minimum required: 0
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later,
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#4400) - 1GB DDR2 Main Storage

Consists of two 512MB DDR2 DIMMs for a total of 1GB of main storage.

  • Attributes provided: 1GB of main storage
  • Attributes required: 2 DIMM slots
  • For 9405-520: (#4400)
    • Minimum required: 0
    • Maximum allowed: 4 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3 with V5R3M5 Machine Code, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE Linux Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

    Used only on Model 520 with 1.9GHz processor (#8325, #8327, #8330).

(#4443) - 512MB DDR-1 Main Storage

(No longer available as of July 08, 2008)

#4443 consists of two 256MB DIMMs for a total of 512MB.

  • Attributes provided: 512MB of main storage
  • Attributes required: 2 DIMM slots
  • For 9405-520: (#4443)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

    For use only on 9405-520 systems with #8950 & #8951 processors.

(#4444) - 1GB DDR-1 Main Storage

(No longer available as of December 02, 2008)

#4444 consists of four 256MB DIMMs for a total of 1GB.

  • Attributes provided: 1GB of main storage
  • Attributes required: 4 DIMM slots
  • For 9405-520: (#4444)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required: i5/OS V5R3, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later, AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

    For use only on 9405-520 systems with #8950 & #8951 processors.

(#4445) - 4GB DDR-1 Main Storage

(No longer available as of December 02, 2008)

#4445 consists of four 1GB DIMMs for a total of 4GB.

  • Attributes provided: 4GB of main storage
  • Attributes required: 4 DIMM slots
  • For 9405-520: (#4445)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

    For use only on 9405-520 systems with #8950 & #8951 processors.

(#4447) - 2GB DDR-1 Main Storage

(No longer available as of December 02, 2008)

#4447 consists of four 512MB DIMMs for a total of 2GB.

  • Attributes provided: 2GB main storage
  • Attributes required: 4 DIMM slots
  • For 9405-520: (#4447)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

    For use only on 9405-520 systems with #8950 & #8951 processors.

(#4449) - 8GB DDR-1 Main Storage

(No Longer Available as of November 27, 2009)

#4449 consists of four 2GB DIMMs for a total of 8GB.

  • Attributes provided: 8GB of main storage
  • Attributes required: 4 DIMM slots
  • For 9405-520: (#4449)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

    For use only on 9405-520 systems with #8950 & #8951 processors.

(#4450) - 16GB DDR-1 Main Storage

(No longer available as of December 02, 2008)

#4450 consists of four 4GB DIMMs for a total of 16GB.

  • Attributes provided: 16GB of main storage
  • Attributes required: 4 DIMM slots
  • For 9405-520: (#4450)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

    For use only on 9405-520 systems with #8950 & #8951 processors.

(#4474) - 2GB DDR2 Main Storage

(No Longer Available as of November 27, 2009)

Consists of two 1GB DDR2 DIMMs for a total of 2GB of main storage.

  • Attributes provided: 2GB of main storage
  • Attributes required: 2 DIMM slots
  • For 9405-520: (#4474)
    • Minimum required: 0
    • Maximum allowed: 4 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3 with V5R3M5 Machine Code, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE Linux Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

    Used only on Model 520 with 1.9GHz processor (#8325, #8327, #8330).

(#4475) - 4GB DDR2 Main Storage

(No Longer Available as of November 27, 2009)

#4475 consists of two 2GB DDR2 DIMMs for a total of 4GB of main storage.

  • Attributes provided: 4GB of main storage
  • Attributes required: Two DDR2 DIMM slots
  • For 9405-520: (#4475)
    • Minimum required: 0
    • Maximum allowed: 4 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3 with V5R3M5 Machine Code, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE Linux Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

    Used only on Model 520 with 1.9GHz processor (#8325, #8327, #8330).

(#4477) - 8GB DDR2 Main Storage

(No Longer Available as of November 27, 2009)

#4477 consists of two 4GB DDR2 DIMMs for a total of 8GB of main storage.

  • Attributes provided: 8GB of main storage
  • Attributes required: Two DIMM slots
  • For 9405-520: (#4477)
    • Minimum required: 0
    • Maximum allowed: 4 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3 with V5R3M5 Machine Code, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE Linux Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

    Used only on Model 520 with 1.9GHz processor (#8325, #8327, #8330).

(#4631) - DVD-ROM

(No longer available as of December 01, 2005)

This DVD-ROM mounts in a removable media device slot. It can read 640MB CD-ROM and 4.7GB DVD-RAM media. #4631 can be used for Alternate IPL (IBM distributed CD-ROM media only) and program distribution.

  • Attributes required: Removable media device slot in an I/O tower
  • For 9405-520: (#4631)
    • Minimum required: 0
    • Maximum allowed: 10 (Initial order maximum: 10)
    • OS level required: i5/OS V5R2, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#4633) - DVD-RAM

(No longer available as of December 01, 2008)

#4633 is a DVD-RAM that uses cartridgeless media only (this is different from the 4630, which can use cartridge media, but the media can be removed from the cartridge to be used in this drive). Media support will be limited to writing DVD-RAM only and reading of CD-ROM, CD-R, DVD-ROM and DVD-RAM.

  • Attributes provided: Read/Write of DVD-RAM media, Read only of CD-ROM, CD-R and DVD-ROM media
  • Attributes required: Removable media device slot in an I/O tower
  • For 9405-520: (#4633)
    • Minimum required: 0
    • Maximum allowed: 15 (Initial order maximum: 15)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#4684) - 30GB 1/4-Inch Cartridge Tape

(No Longer Available as of November 27, 2009)

The #4684 is a 30GB 1/4-Inch Cartridge Tape Unit that can be mounted in half-high, autodocking, removable media bays of expansion towers/units.

The #4684 may be used for save/restore, alternate IPL, program distribution, migration and 1/4-inch cartridge tape exchange.

A #4684 will read/write the following tape formats:

  • 30GB (up to 60GB with compression in SLR60 format) with IBM SLR60-30GB Data Cartridge (19P4209)
  • 25GB (up to 50GB with compression in MLR3 format) with IBM MLR3-25GB Data Cartridge (59H4128)
  • 16GB (up to 32GB with compression in QIC5010 format) with IBM MLR1-16GB Data Cartridge (59H4175)
  • 5GB (up to 10GB with compression in SLR100 format) with IBM SLR100-5GB Data Cartridge (35L0661)
  • 2GB (up to 4GB with compression in QIC5010 format) with IBM MLR1-2GB Data Cartridge (35L0589)

A #4684 is capable of read only support of the following tape formats:

  • 4GB (QIC4GB format) with SLR5-4GB Data Cartridge (59H3660)
  • 2.5GB (QIC2GB format) with IBM DC9250 Data Cartridge (16G8436)

The #4684 has the these technical specifications for the primary recording format:

  • Cartridge Capacity (Native) = 30.0GB (1500-ft tape)
  • Cartridge Capacity (Compression) = 60.0GB (1500-ft tape)
  • Data Rate (Native) = 4.0MB/s
  • Data Rate (Compression) = 8.0MB/s
  • Attributes provided: 30GB 1/4-inch tape device
  • Attributes required: half height, autodocking removable media bay and a disk controller in place to interface to this media bay.
  • For 9405-520: (#4684)
    • Minimum required: 0
    • Maximum allowed: 10 (Initial order maximum: 10)
    • OS level required: i5/OS V4R5, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#4685) - 80GB VXA-2 Tape Drive

(No longer available as of May 08, 2007)

The #4685 is a 80GB 8mm Cartridge Tape Unit that can be mounted in half-high, autodocking, removable media bays of expansion towers/ units.

The #4685 may be used for save/restore, alternate IPL, program distribution, migration.

The #4685 has the these technical specifications for the primary recording format:

  • Cartridge Capacity (Native) = 80.0GB
  • Cartridge Capacity (Compression) = 160.0GB (typical)
  • Data Rate (Native) = 6.0MB/s
  • Data Rate (Compression) = 12.0MB/s
  • Recording Format: 8mm helical scan
  • Interchange (Read): New format (No compatible tape currently offered on iSeries)
  • Interchange (Write): New format (No compatible tape currently offered on iSeries)
  • Form Factor 5 1/4", 1/2 high

A #4685 will read/write the following tape format:

  • Advanced Metal Evaporated 8mm data cartridges
    • 230m (80GB)
    • 61m (20GB)
    • 170m (59GB)
  • Attributes provided: 80GB 8mm tape device
  • Attributes required: Half-height, autodocking removable media bay and a disk controller in place to interface to this media bay.
  • For 9405-520: (#4685)
    • Minimum required: 0
    • Maximum allowed: 10 (Initial order maximum: 10)
    • OS level required: i5/OS V5R1, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#4687) - 50GB 1/4-Inch Cartridge Tape

(No Longer Available as of November 27, 2009)

Mounted in a removable media device slot of a system unit or an expansion tower, these tape units may be used for save/restore, alternate IPL, program distribution, migration and 1/4-inch cartridge tape exchange.

Will READ/WRITE:

  • 50GB (up to 100GB with compression in SLR100 format) with IBM SLR100-50GB Data Cartridge (35L0968)
  • 30GB (up to 60GB with compression in SLR60 format) with IBM SLR60-30GB Data Cartridge (19P4209)
  • 25GB (up to 50GB with compression in MLR3 format) with IBM MLR3-25GB Data Cartridge (59H4128)
  • 5GB (up to 10GB with compression in SLR100 format) with IBM SLR100-5GB Data Cartridge (35L0661)

Will READ:

  • 16GB (up to 32GB with compression in QIC5010 format) with IBM MLR1-16GB Data Cartridge (59H4175)
  • 4GB (QIC4GB format) with SLR5-4GB data Cartridge (59H3660)
  • 2GB (up to 4GB with compression in QIC5010 format) with IBM MLR1-2GB

Specifications for the primary recording format:

  • Cartridge Capacity (Native) = 50.0GB (1500-ft tape)
  • Cartridge Capacity (Compression) = 100.0GB (1500-ft tape)
  • Data Rate (Native) = 5.0MB/s
  • Data Rate (Compression) = 10.0MB/s
  • Attributes provided: 50GB 1/4-inch Cartridge Tape Device
  • Attributes required: Half-high removable media bay and a controller in place to interface to this media bay
  • For 9405-520: (#4687)
    • Minimum required: 0
    • Maximum allowed: 10 (Initial order maximum: 10)
    • OS level required: i5/OS V5R1, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#4688) - 160GB VXA-320 Tape Drive

(No longer available as of May 08, 2007)

Provides a 160GB native capacity (320GB compressed capacity) VXA-320 tape device that installs in a half-high removable media device slot in an expansion unit. The #4688 reads and writes VXA-320 and VXA-2 format tapes and reads VXA-1 format tapes.

Characteristics:

  • Capacity: 160GB native mode, 320GB (typical) compression mode
  • Form Factor: 5.25-inch, half-high
  • Mounting type: auto-docking
  • Media: VXA tape data cartridges
  • Technology: Helical scan, rotating head
  • Operation: Streaming
  • Data Transfer Rate: 12MBps native mode, 24MBps (typical) compression
  • Interface: Ultra2 SCSI, 16-bit (wide), LVD and SE compatible
  • Compatibility: VXA-320 format (Read/Write), VXA-2 format (Read/ Write), VXA-1 format (Read)
  • Attributes provided: 160/320GB VXA-320 Tape Device
  • Attributes required: One 5.25-inch, Half-high Removable Media Device Slot
  • For 9405-520: (#4688)
    • Minimum required: 0
    • Maximum allowed: 12 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE Linux Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#4690) - Rack Status Beacon Assembly

(No longer available as of July 15, 2005)

The Rack Status Beacon is designed to be placed on the top of a rack and cabled to multiple components inside the rack. Servers in the rack can be programmed to illuminate the beacon in response to any detected problems or changes in status. The Rack Status Beacon has redundant AC power inputs and draws its power from the rack Power Distribution Unit (PDU) outlets. At least one #6458 power cord must be ordered to connect the Rack Status Beacon to the PDU.

  • Attributes provided: Indication of rack status
  • Attributes required: Junction box (#4693) and at least 2 cables (#4691); one or two #6458 power cords
  • For 9405-520: (#4690)
    • Minimum required: 0
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#4691) - Rack Status Beacon Cable

(No longer available as of July 15, 2005)

This cable can be used to connect the Rack Status Beacon Junction Box to a supported rack drawer or to the Rack Status Beacon.

  • Attributes provided: Connection between Rack Status Beacon components
  • Attributes required: None
  • For 9405-520: (#4691)
    • Minimum required: 0
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#4692) - Junction Box Cable

(No longer available as of July 15, 2005)

This cable is used to connect two Rack Status Beacon Junction Boxes (#4693) together. Multiple Junction Boxes may be linked in series, as required.

  • Attributes provided: Connection between (#4692) Junction Boxes
  • Attributes required: Two or more (#4692) Junction Boxes
  • For 9405-520: (#4692)
    • Minimum required: 0
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#4693) - Rack Beacon Junct Box Cable

(No longer available as of July 15, 2005)

This feature provides six input connectors and one output connector for racks configured with the Rack Status Beacon (#4690). Multiple Junction Boxes can be linked together in series with Junction Box Cable (#4692).

  • Attributes provided: Connection of multiple drawers to a single Rack Status Beacon (#4690).
  • Attributes required: Feature #4690 and two or more #4691 cables.
  • For 9405-520: (#4693)
    • Minimum required: 0
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#4746) - PCI Twinaxial Workstn IOA

(No Longer Available as of November 27, 2009)

The #4746 provides support for up to 40 twinaxial displays and printers. A 20-ft cable with an 8-port expansion (breakout) box is included with this adapter. Each expansion port supports seven attached devices, allowing for 56 total attached devices, of which only 40 can be active.

  • Attributes provided: Attachment of twinaxial devices.
  • Attributes required: One PCI slot (3V or 5V)
  • For 9405-520: (#4746)
    • Minimum required: 0
    • Maximum allowed: 48 (Initial order maximum: 48)
    • OS level required: i5/OS V4R5, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#4801) - PCI Crypto Coprocessor

(No longer available as of June 01, 2006)

#4801 provides a rich set of data encryption and authentication services for applications requiring high security. Cryptographic keys are stored in a tamper-resistant module on the coprocessor. This feature is ideally suited for banking and financial applications. With the tamper resistant-module the coprocessor can also be used to implement other advanced applications such as electronic postage metering.

Application services provided by the coprocessor include:

  • Data encryption using Tripe-DES (Data Encryption Standard)
  • Digital signature generation/verification using RSA public-key cryptography
  • Data integrity checking using MD5 and SHA-1 secure hash algorithms
  • Financial PIN support for automatic teller machine (ATM) networks
  • Basic Secure Electronic Transaction (SET) block operations
  • Secure storage of keys in a Federal Information Processing Standard (FIPS) 140-1 Level 3 tamper-resistant module

The PCI Cryptographic Coprocessor is compatible with IBM's Common Cryptographic Architecture (CCA).

For more information, visit:

http://www.ibm.com/security/cryptocards/

Option 35 CCA Cryptographic Service Provider is required along with Cryptographic Access Provider 128-bit (5722-AC3) licensed program. Both Option 35 and the LPP are no-charge.

  • For 9405-520: (#4801)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required: i5/OS V4R5, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#4805) - PCI Crypto Accelerator

(No longer available as of June 01, 2006)

Feature #4805 provides improved performance for high-transaction-rate secure Web applications which use the secure sockets layer (SSL) or transport layer security (TLS) protocols. SSL/ TLS is the predominant method for securing Web transactions. Applications using SSL/TLS include those transferring payment information (e.g., credit card numbers) over the Internet, e.g., between a Web browser and a server in the case of B2C or between servers in the case of B2B. Establishing SSL/TLS secure Web connections requires very compute intensive cryptographic processing. Feature #4805 off-loads cryptographic processing associated with the establishment of a SSL/TLS session, thus freeing the server for other processing.

The Cryptographic Accelerator is targeted to high-transaction-rate secure Web applications using SSL/TLS. If your application requires a FIPS 140-1 certified, tamper-resistant module for storing cryptographic keys and/or requires financial PIN processing, then features #4801 or #4802, Cryptographic Coprocessors should be your choice.

Note: FIPS 140-1 is a U.S. Government National Institute of Standards and Technology (NIST) administered standard and certification program for cryptographic modules.

For additional information, visit:

http://www.ibm.com/eserver/iseries/support

  • For 9405-520: (#4805)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required: i5/OS V5R2, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#4806) - PCI-X Crypto Coprocessor

(No Longer Available as of November 27, 2009)

Provides both cryptographic coprocessor and secure-key cryptographic accelerator functions in a single PCI-X card. The coprocessor functions are targeted to banking and finance applications. Financial PIN processing and Europay, MasterCard, Visa (EMV) credit card functions are provided. EMV is a standard for integrated-chip based credit cards. The secure-key accelerator functions are targeted to improving the performance of i5/OS Secure Sockets Layer (SSL) transactions. The #4806 provides the security and performance required to support eBusiness and emerging digital signature applications.

The #4806 provides secure storage of cryptographic keys in a tamper- resistant hardware security module (HSM), which is designed to meet FIPS 140-1 and 2 security requirements. FIPS 140 is a U.S. Government National Institute of Standards and Technology (NIST) administered standard and certification program for cryptographic modules.

The firmware for the #4806 is available on a separately ordered/ distributed CD. This firmware is an LPO product: 5733-CY1 Cryptographic Device Manager. The #4806 also requires LPP 5722-AC3 Cryptographic Access Provider to enable data encryption.

This feature has country-specific usage. Refer to the IBM representatives in your country for availability or restrictions.

  • Attributes provided: Cryptographic Accelerator Function, EMV-Based Credit Card Function
  • Attributes required: One PCI-X card slot, LPO 5733-CY1, LPP 5722-AC3
  • For 9405-520: (#4806)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#4810) - PCI Integ xSeries Server

(No longer available as of June 01, 2006)

The #4810 PCI Integrated xSeries Server contains a 2GHz processor and four memory slots.Each server memory slot can contain one of the following features, providing a total main storage capacity from 1,024 MB to 4,096 MB.

  • 512MB Server Memory (#0446)
  • 1GB Server Memory (#0447)

At least two server memory cards are required with each server feature. Server memory cards must be installed in identical capacity pairs. On model upgrades or MES orders, a server feature may be ordered without memory features if usable supported memory features already exist on the installed system.

The #4810 contains one integrated 100/10Mbps Ethernet LAN controller and can support the following LAN IOAs:

  • PCI 100/16/4Mbps Token-Ring IOA (#2744)
  • PCI 1Gbps Ethernet IOA (#5700)
  • PCI 1Gbps Ethernet UTP IOA (#5701)

When a LAN feature is used in conjunction with the #4810, the following ordering rules apply:

  • For each #2744 that is driven, one #0223, 100/16/4Mbps Token-Ring Specify, is required.
  • For each #5700/#5701 that is driven, one #0226 (1Gbps Ethernet Specify)is required.
  • Up to three IOA LAN features can be supported by the #4810, depending on the system unit/tower position into which the #4810 is placed.

Native AS/400 functions are not supported.

The #4810 does not support external host LAN.

The #4810 does not require a #2843, #2844, #9943 or #9844 IOP, but placement is limited to specific slots within the various system expansion towers. Two PCI card slots are required.

The #4810 comes with a standard keyboard/mouse splitter cable and can support either standard or USB 1.1 keyboard and/or mouse.

Windows 2000 Server and Windows 2003 Server operating systems are supported.

IPCS Extension Cable for Windows (#0325) is defaulted on the order for each #4810(but may be removed).

A minimum of 1GB Server memory is required.

IPCS Keyboard/Mouse for Windows (#1700) is defaulted on the order for each #4810(in countries offering it, but may be removed).

A display must be connected to the #4810 to support Windows.

The #4810 is normally a CSU feature, but if installed in a #5074, #5079, #5094, #5294 or #9194, IBM service personnel should do the installation.

  • Attributes provided: Integrated xSeries Server support
  • Attributes required: Two PCI slots (only designated locations in an expansion tower/unit can be used).
  • For 9405-520: (#4810)
    • Minimum required: 0
    • Maximum allowed: 18 (Initial order maximum: 18)
    • OS level required: i5/OS V5R2, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#4811) - PCI Integ xSeries Server

(No longer available as of July 01, 2008)

#4811 is a double wide PCI card which contains a 2.0GHz processor with 2MB integrated L2 cache. It has two integrated 1000/100/10Mbps ethernet ports, two USB 1.1 ports and traditional PC keyboard and mouse ports. A keyboard and mouse can either connect to the traditional ports or connect to the USB ports. There is an SVGA video port for connection of a display.

#4811 has two memory slots. These slots must always contain a pair of identical memory features. Available memory features are:

  • #9726 - Base 512MB Server Memory (Initial order only)
  • #8546 - Opt Base 1GB Server Memory (Initial order only)
  • #0446 - 512MB DDR Server Memory (MES only)
  • #0447 - 1GB DDR Server Memory (MES only)

The #4811 requires an IOP (#9744, #2844 or #9844) to drive it. The IOP may be shared, but only one #4811 is permitted per IOP.

When #4811 is ordered, the configurator will add two #9726 Base 512MB Server Memory features to the order. The two #9726 features may be replaced with two #8546 Optional Base 1GB Server Memory features or the two server memory features may be removed from the order and two #0446 or two #0447 may be installed in the field. The configurator will also add to the order a #9744 Base PCI IOP to drive the #4811. The #9744 may be removed from the order for PCI slot conservation.

The two integrated 1000/100/10Mbps Ethernet LAN ports included on the #4811 provide attachment to IEEE standard 802.3ab high-speed(1Gbps) Ethernet LANs. They can also be used to connect to existing 10 and 100Mbps Ethernet networks. The adapter supports UTP CAT 5 or higher media interface and TCP/IP. The #4811 does not support any other LAN features and does not support native i5/OS functions.

The following features are defaulted (where offered) and may be removed from the order:

  • #0325 IPCS Extension Cable for Windows (for display, mouse and and keyboard)
  • #1700 IPCS Keyboard and Mouse for Windows

Supported Windows versions:

  • Windows 2000 Server
  • Windows 2000 Advanced Server
  • Windows Server 2003 Standard Edition
  • Windows Server 2003 Enterprise Edition
  • Windows Server 2003 Web Edition

For versions of Windows 2000, a display is required and must be connected to the #4811. For versions of Windows 2003, a display is not required but may be connected to the #4811 to support Windows. If no display is connected, the Virtual System Console is used.

For Linux server products supported on #4811, see:

www.ibm.com/eserver/iseries/integratedxseries/linux

  • Attributes provided: Windows server functions
  • Attributes required: IOP and two 3.3V PCI card slots
  • For 9405-520: (#4811)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required:
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

    The #4811 may be placed only in the model 520 system unit.

(#4812) - PCI Integ xSeries Server

(No longer available as of July 01, 2008)

#4812 is a double wide PCI card that contains a 2.0GHz processor with 2MB integrated L2 cache. It has two integrated 1000/100/10Mbps ethernet ports, two USB 1.1 ports and traditional PC keyboard and mouse ports. A keyboard and mouse can either connect to the traditional ports or connect to the USB ports. There is an SVGA video port for connection of a display.

#4812 has two memory slots. These slots must always contain a pair of identical memory features. Available memory features are:

  • #9726 - Base 512MB Server Memory (Initial order only)
  • #8546 - Opt Base 1GB Server Memory (Initial order only)
  • #0446 - 512MB DDR Server Memory (MES only)
  • #0447 - 1GB DDR Server Memory (MES only)

The #4812 requires an IOP (#9744, #2844 or #9844) to drive it. The IOP may be shared, but only one #4812 is permitted per IOP.

When #4812 is ordered, the configurator will add two #9726 Base 512MB Server Memory features to the order. The two #9726 features may be replaced with two #8546 Optional Base 1GB Server Memory features or the two server memory features may be removed from the order and two #0446 or two #0447 may be installed in the field. The configurator will also add to the order a #9744 Base PCI IOP to drive the #4812. The #9744 may be removed from the order for PCI slot conservation.

The two integrated 1000/100/10Mbps Ethernet LAN ports included on the #4812 provide attachment to IEEE standard 802.3ab high-speed (1Gbps) Ethernet LANs. They can also be used to connect to existing 10 and 100Mbps Ethernet networks. The adapter supports UTP CAT 5 or higher media interface and TCP/IP. The #4812 does not support any other LAN features and does not support native i5/OS functions.

The following features are defaulted (where offered) and may be removed from the order:

  • #0325 IPCS Extension Cable for Windows (for display, mouse and and keyboard)
  • #1700 IPCS Keyboard and Mouse for Windows

Supported Windows versions:

  • Windows 2000 Server
  • Windows 2000 Advanced Server
  • Windows Server 2003 Standard Edition
  • Windows Server 2003 Enterprise Edition
  • Windows Server 2003 Web Edition

For versions of Windows 2000, a display is required and must be connected to the #4812. For versions of Windows 2003, a display is not required but may be connected to the #4812 to support Windows. If no display is connected, the Virtual System Console is used.

For Linux server products supported on #4812, see:

www.ibm.com/eserver/iseries/integratedxseries/linux

  • Attributes provided: Windows server functions
  • Attributes required: IOP and two 3.3V PCI card slots
  • For 9405-520: (#4812)
    • Minimum required: 0
    • Maximum allowed: 18 (Initial order maximum: 18)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

    #4812 may only be installed in expansion unit (not in #5790)

(#4813) - PCI Integ xSeries Server

(No longer available as of July 01, 2008)

#4813 is a double-wide PCI card that contains a 2.0GHz processor with 2MB integrated L2 cache. It has two integrated 1000/100/10Mbps Ethernet ports, two USB 1.1 ports and traditional PC keyboard and mouse ports. A keyboard and mouse can connect to either the traditional ports or the USB ports. There is an SVGA video port for connection of a display.

The #4813 is a #4812 encased in a double wide blind swap cassette.

#4813 has two memory slots. These slots must always contain a pair of identical memory features. Available memory features are:

  • #9726 - Base 512MB Server Memory (Initial order only)
  • #8546 - Opt Base 1GB Server Memory (Initial order only)
  • #0446 - 512MB DDR Server Memory (MES only)
  • #0447 - 1GB DDR Server Memory (MES only)

The #4813 requires an IOP (#9744, #2844 or #9844) to drive it. The IOP may be shared, but only one #4813 is permitted per IOP.

When #4813 is ordered, the configurator will add two #9726 Base 512MB Server Memory features to the order. The two #9726 features may be replaced with two #8546 Optional Base 1GB Server Memory features or the two server memory features may be removed from the order and two #0446 or two #0447 may be installed in the field. The configurator will also add to the order a #9744 Base PCI IOP to drive the #4813. The #9744 may be removed from the order for PCI slot conservation.

The two integrated 1000/100/10Mbps Ethernet LAN ports included on the #4813 provide attachment to IEEE standard 802.3ab high-speed (1Gbps) Ethernet LANs. They can also be used to connect to existing 10 and 100Mbps Ethernet networks. The adapter supports UTP CAT 5 or higher media interface and TCP/IP. The #4813 does not support any other LAN features and does not support native i5/OS functions.

The following features are defaulted (where offered) and may be removed from the order:

  • #0325 IPCS Extension Cable for Windows (for display, mouse and and keyboard)
  • #1700 IPCS Keyboard and Mouse for Windows

Supported Windows versions:

  • Windows 2000 Server
  • Windows 2000 Advanced Server
  • Windows Server 2003 Standard Edition
  • Windows Server 2003 Enterprise Edition
  • Windows Server 2003 Web Edition

For versions of Windows 2000, a display is required and must be connected to the #4813. For versions of Windows 2003, a display is not required but may be connected to the #4813 to support Windows. If no display is connected, the Virtual System Console is used.

For Linux server products supported on #4813, visit:

http://www.ibm.com/eserver/iseries/integratedxseries/linux

  • Attributes provided: Windows server functions
  • Attributes required: IOP and two 3.3V PCI card slots
  • For 9405-520: (#4813)
    • Minimum required: 0
    • Maximum allowed: 18 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

    #4813 may only be installed in a #5790 PCI Expansion Drawer.

(#4959) - PCI 16/4Mbps Token-Ring IOA

(No longer available as of December 01, 2005)

The #4959 IBM Token-Ring PCI Adapter is a single slot, short, 32-bit, PCI adapter supporting 4 or 16 Mbps data rates, either half-duplex or full-duplex.

Automatic Ring-Speed selection prevents "wrong speed" insertion into the ring, even when connected to speed-sensing hubs. This adapter will operate with either unshielded twisted pair (UTP) Cat 5 cable with RJ-45 connectors or shielded twisted pair (STP) Type 1A cabling with 9-pin D-shell connectors. The Token-Ring PCI Adapter will provide network boot capability.

  • Attributes provided: Token Ring connectivity
  • Attributes required: A single empty 32-bit PCI adapter slot, #0140 (Logical Partitioning Specify) and #0145 (AIX Partition Specify)
  • For 9405-520: (#4959)
    • Minimum required: 0
    • Maximum allowed: 20 (Initial order maximum: 20)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#4962) - PCI 100/10Mbps Ethernet IOA

(No longer available as of December 01, 2005)

The #4962 10/100 Mbps Ethernet PCI Adapter II is a small form factor, single port PCI ethernet adapter. This high performance, low power ethernet 10/100Mbps LAN adapter can be used in both client and server PCI systems. The 10/100 Mbps Ethernet PCI Adapter I supports:

  • Half / Full Duplex 10/100 Mbps Ethernet interface
  • 10/100 Mbps data rates
  • Auto-negotiation for 10/100 speed and half/full duplex
  • Network boot capability and Network Install Manager (NIM)
  • IEEE 802.3 Ethernet Specification
  • IEEE 802.3u Fast Ethernet Specification

The 10/100 Mbps Ethernet PCI Adapter II also supports the off-load of IP Security cryptographic algorithms by providing hardware assistance in performing data encryption and authentication. This support is provided with AIX 5.2 and later.

An additional function called 'Large Send' or sometimes known as TCP Segmentation is also available. This function offloads the TCP segmentation operation from the AIX IP layer to the adapter for outgoing (transmit side) TCP segments.

  • Attributes provided: One 10/100 Mbps Ethernet port (connector)
  • Attributes required: One PCI slot and #0140 (Logical Partitioning Specify) and (#0142 (Linux Partition Specify) or #0145 (AIX Partition Specify))
  • For 9405-520: (#4962)
    • Minimum required: 0
    • Maximum allowed: 34 (Initial order maximum: 34)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5000) - Software Preload Required

Indicates that preloaded software and/or consolidated I/O is shipped with the initial order. A maximum of one (#5000) is supported. This feature has country-specific usage.

  • For 9405-520: (#5000)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A

(#5001) - Customer Solution Center

(No Longer Available as of November 27, 2009)

Indicates that a machine is to be routed to the Customer Solution Center at time of manufacture. Order content is routed to the CSC in Bldg. 673. Multiple #5001s are allowed on the records. This feature has country-specific usage.

  • Attributes provided: Order content is routed to CSC in Bldg 673 (Rochester).
  • Attributes required: None
  • For 9405-520: (#5001)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V2R1, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5002) - System i CDSC-Rochester Mfg

Indicates that machine is to be routed to the CDSC. This feature has country-specific usage.

  • For 9405-520: (#5002)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V2R2, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A

(#5088) - PCI-X Expansion Unit

(No longer available as of June 01, 2006)

The #5088 is an eight-EIA-unit-high "top hat" with is installed on top of a #5074/#5094 expansion tower. Each #5088 has 14 PCI-X slots for PCI IOPs and IOAs. Disk units and removable media are not supported within a #5088.

Each #5088 has two redundant 575W power supplies and two internal power connectors that attach to the AC distribution box in the #5074/ #5094. A #5074/#5094 may have one or two line cords, so the #5088 may or may not have dual line cord capability depending on the configuration of the #5074/#5094.

If a #5088 is ordered together with a #5094, the #5094 will ship with a #5088 installed on top. The #5088 may also be ordered for field install on an existing #5074/#5094. A #5088 may not be installed on a #5294 or #5079.

A bus adapter is required to provide the HSL interface to the system. Select one of the following:

  • #9877 - Base HSL-2 Bus Adapter, to specify two copper HSL-2 ports
  • #9876 - Base Optical Bus Adapter, to specify two optical HSL ports

One or two HSL cables must be ordered to attach the #5088 to the HSL or HSL-2 ports.

When ordering cables to connect to the HSL interface, optical HSL, copper HSL, copper HSL-2, or copper HSL to HSL-2 cables are required.

An HSL loop uses all optical or all copper ports/cables. A copper loop can intermix I/O towers/units with copper HSL and copper HSL-2 ports. Select the appropriate cable based on the type of HSL ports to which it is being attached, and the cable length required.

  • #1307 - 1.75m HSL-2 Cable
  • #1308 - 2.5m HSL-2 Cable
  • #1470 - 6m HSL Optical Cable (model 570 only)
  • #1471 - 30m HSL Optical Cable (model 570 only)
  • #1472 - 100m HSL Optical Cable (model 570 only)
  • #1473 - 250m HSL Optical Cable (model 570 only)
  • #1474 - 6m HSL to HSL-2 Cable
  • #1475 - 10m HSL to HSL-2 Cable
  • #1481 - 1m HSL-2 Cable
  • #1482 - 3.5m HSL-2 Cable
  • #1483 - 10m HSL-2 Cable
  • #1485 - 15m HSL-2 Cable

Each #5088 will require one of the following SPCN cables:

  • #1463 - 2m SPCN Cable
  • #1464 - 6m SPCN Cable
  • #1465 - 15m SPCN Cable
  • #1466 - 30m SPCN Cable
  • #0369 - 100m Optical SPCN Cable (model 570 only)
  • #1468 - 250m Optical SPCN Cable (model 570 only)
  • #6001 - 2m SPCN Cable
  • #6006 - 3m SPCN Cable
  • #6007 - 15m SPCN Cable
  • #6008 - 6m SPCN Cable
  • #6029 - 30m SPCN Cable
  • Attributes provided: 14 PCI-X slots
  • Attributes required: Two HSL connections
  • For 9405-520: (#5088)
    • Minimum required: 0
    • Maximum allowed: 6 (Initial order maximum: 6)
    • OS level required: i5/OS V5R2, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: No

(#5094) - PCI-X Expansion Tower

(No longer available as of May 29, 2009)

The #5094 is an I/O expansion tower that can contain up to 45 disk units, has 14 PCI slots and two removable media bays.

One bus adapter to provide the HSL interface to the system is required with each #5094. Select one of the following:

  • #9517 - Base HSL-2 Bus Adapter, to specify two copper HSL-2 ports
  • #9876 - Base Optical Bus Adapter, to specify two optical HSL ports

One or two cables must be ordered to attach to the HSL or HSL-2 ports. When ordering cables to connect to the HSL interface, optical HSL, copper HSL, copper HSL-2, or copper HSL to HSL-2 cables are required. An HSL loop uses all optical or all copper ports/cables. A copper loop can intermix I/O towers/units with copper HSL and copper HSL-2 ports. Select the appropriate cable based on the type of HSL ports to which it is being attached and the cable length required.

The following HSL cables can be used with a #5094:

  • #1307 1.75m HSL-2 Cable
  • #1308 2.5m HSL-2 Cable
  • #1460 3m HSL Cable
  • #1461 6m HSL Cable
  • #1462 15m HSL Cable
  • #1470 6m HSL Optical Cable (model 570 only)
  • #1471 30m HSL Optical Cable (model 570 only)
  • #1472 100m HSL Optical Cable (model 570 only)
  • #1473 250m HSL Optical Cable (model 570 only)
  • #1464 6m HSL to HSL-2 Cable
  • #1475 10m HSL to HSL-2 Cable
  • #1481 1m HSL-2 Cable
  • #1482 4m HSL-2 Cable
  • #1483 10m HSL-2 Cable

One SPCN cable is required for each #5094. Select from the following:

  • #1463 2m SPCN Cable
  • #1464 6m SPCN Cable
  • #1465 15m SPCN Cable
  • #1466 30m SPCN Cable
  • #0369 100m Optical SPCN Cable (model 570 only)
  • #1468 250m Optical SPCN Cable (model 570 only)
  • #6001 2m SPCN Cable
  • #6006 3m SPCN Cable
  • #6007 15m SPCN Cable
  • #6008 6m SPCN Cable
  • #6029 30m SPCN Cable

Each #5094 includes a #9844 Base PCI IOP.

Note: With the availability of V5R4, #9844 is no longer included with #5094.

Each #5094 can support 15 disk units without a #5108 installed. With #5108 installed, a #5094 can support up to 45 disk units, total.

Each #5094 comes with redundant, hot-swap, power supplies.

To enable further #5094 redundancy, dual line cord capability for the #5094 is provided by feature#5115. An additional #5094 line cord must be ordered when installing a #5115. Plugging in the second line cord, even if to the same outlet, enables the AC power modules to be redundant.

The following line cords are supported on a #5094:

  • #1399 - 4.3m 300V/16A
  • #1406 - 200V 16A 14-Ft TL Line Cord
  • #1408 - 4.3m 200V/16A Pwr Cd Italy
  • #1409 - 4.3m 200V/16A Pwr Cd AU/NZ
  • #1418 - 4.3m 200V/16A Pwr Cd S Afric
  • #1419 - 4.3m 200V/16A Pwr Cd Israel
  • #1420 - 4.3m 200V/16A Pwr Cd EU/Asia
  • #1421 - 4.3m 200V/16A Pwr Cd CH/DK
  • #1451 - 200V 6-Ft Line Cord
  • #1452 - 200V 14-Ft Line Cord
  • #1453 - 200V 6-Ft Locking Line Cord
  • #1454 - 200V 12A 14-Ft TL Line Cord (U.S. default)
  • #1455 - 200V 6-Ft Wtrtght Line Cord
  • #1456 - 200V 14-Ft Wtrtght Line Cord
  • #1476 - 4.3m 200V/12A Pwr Cd UK

The 45 disk unit positions are in groups of 15, each group of 15 disk units is further divided into three groups of five disk units, each group of five disk units supported on a separate SCSI (LVD-SCSI) bus from a #4748/#4778/#2757/#2780/#5703/#5715 PCI Disk Unit Controller.

The #5094 removable media bays are supported by the same #4748/ #4778/#2757/#2780/#5703/#5715 PCI Disk Unit Controller which supports the 5 base disk unit positions (disk slot positions D31 thru D50).

  • Attributes provided: 14 PCI slots, up to 45 disk positions (15 base, 0 featurable), two removable media bays
  • Attributes required: HSL connection (either copper or optical)
  • For 9405-520: (#5094)
    • Minimum required: 0
    • Maximum allowed: 6 (Initial order maximum: 0)
    • OS level required: i5/OS V5R2, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5095) - PCI-X Expansion Tower

(No longer available as of December 02, 2008)

The #5095 is a stand-alone (desk side) PCI-X Expansion Tower that provides expanded I/O capability for iSeries systems. The #5095 has seven PCI-X IOP/IOA slots and supports up to 12 disk units.

A #9844 Base PCI IOP is included with each #5095.

Note: With the availability of V5R4, #9844 is no longer included with #5095.

A bus adapter to provide the HSL interface to the system is required. Select one of the following:

  • #9517 - Base HSL-2 Bus Adapter, to specify two copper HSL-2 ports
  • #9876 - Base Optical Bus Adapter, to specify two optical HSL ports

    Note: If ordered for a 9408-M25 or 9409-M50 a #6699 (RIO-2 Bus Adapter) must be ordered instead of a #9517 or #9876.

One or two HSL cables must be ordered with each #5095.

When ordering cables to connect to the HSL interface, optical HSL, copper HSL, copper HSL-2, or copper HSL to HSL-2 cables are required. An HSL loop uses all optical or all copper ports/cables. A copper loop can intermix I/O towers/units with copper HSL and copper HSL-2 ports. Select the appropriate cable based on the type of HSL ports to which it is being attached, and the cable length required.

The following HSL cables can be used with a #5095:

  • Copper HSL to HSL-2 (HSL on one end and HSL-2 on the other end)
    • #1474 - 6m HSL to HSL-2 Cable
    • #1475 - 10m HSL to HSL-2 Cable
    • #1487 - 3m HSL to HSL-2 Cable
  • Copper HSL-2 (HSL-2 on both ends of the cable)
    • #1307 - 1.75m HSL-2 Cable
    • #1308 - 2.5m HSL-2 Cable
    • #1481 - 1.2m HSL-2 Cable
    • #1482 - 3.5m HSL-2 Cable
    • #1483 - 10m HSL-2 Cable
    • #1485 - 15m HSL-2 Cable
  • Optical HSL (optical HSL connections on both ends of the cable)
    • #1470 - 6m HSL Optical Cable
    • #1471 - 30m HSL Optical Cable
    • #1472 - 100m HSL Optical Cable
    • #1473 - 250m HSL Optical Cable

One SPCN cable is required with each #5095. Select one of the following:

  • #1463 - 2m SPCN Cable
  • #1464 - 6m SPCN Cable
  • #1465 - 15m SPCN Cable
  • #1466 - 30m SPCN Cable
  • #0369 - 100m Optical SPCN Cable
  • #1468 - 250m Optical SPCN Cable
  • #6001 - 2m SPCN Cable
  • #6006 - 3m SPCN Cable
  • #6007 - 15m SPCN Cable
  • #6008 - 6m SPCN Cable
  • #6029 - 30m SPCN Cable

The #5095 has redundant power when feature #5138 is installed. The #5138 provides a second 435W power supply. In addition, when a #5138 is installed, a second line cord must be ordered. The presence of the #5138 and the second line cord, enables dual line cord capability.

Select one of the following line cords, or select two if #5138 is ordered:

  • #1394 - 4.3m 200V/10A Pwr Crd Brazil
  • #1395 - 4.3m 200V/10A Pwr Cd China
  • #1397 - 4.3m 200V/10A Pwr Crd Argent
  • #1398 - 4.3m 100V/10A Pwr Crd Brazil
  • #1410 - 200V 6-Ft Line Cord
  • #1411 - 200V 14-Ft Line Cord
  • #1412 - 125V 6-Ft Line Cord
  • #1413 - 125V 14-Ft Line Cord
  • #1414 - 200V 6-Ft Locking Line Cord
  • #1415 - 200V 6-Ft Watertight Line Cord
  • #1416 - 200V 14-Ft Locking Line Cord
  • #1417 - 200V 14-Ft Wtrtght Line Cord
  • #1422 - 3m IEC 320 C13/14 PDU Cord
  • #1438 - 4.3m 200V/10A Pwr Cd AU/NZ
  • #1439 - 4.3m 200V/10A Pwr Cd EU/Asia
  • #1440 - 4.3m 200V/10A Pwr Cd Denmark
  • #1441 - 4.3m 200V/10A Pwr Cd S Africa
  • #1442 - 4.3m 200V/10A Pwr Cd Swiss
  • #1443 - 4.3m 200V/10A Pwr Cd UK
  • #1444 - 4.3m 200V/10A Pwr Cd Italy
  • #1445 - 4.3m 200V/10A Pwr Cd Israel
  • #6458 - 14-Ft Int 250V/10A Pwr Cd
  • #6460 - 14-Ft 125V/15A Power Cord
  • #6469 - 14-Ft 250V/15A Power Cord
  • #6470 - 6-Ft 125V/15A Power Cord
  • #6471 - 9-Ft 125V/15A Power Cord
  • #6472 - 9-Ft 250V/16A Power Cord
  • #6473 - 9-Ft 250V/10A Power Cord
  • #6474 - 9-Ft 250V/13A Power Cord
  • #6475 - 9-Ft 250V/16A Power Cord
  • #6476 - 9-Ft 250V/10A Power Cord
  • #6477 - 9-Ft 250V/10A Power Cord
  • #6478 - 9-Ft 250V/16A Power Cord
  • #6479 - 9-Ft 250V/10A Power Cord
  • #6487 - 6-Ft 250V/15A Power Cord
  • #6488 - 9-Ft Dual Voltage Pwr Cd
  • #6493 - 9-Ft 250V/10A Power Cord
  • #6494 - 9-Ft 250V/10A Power Cord
  • #6495 - 9-Ft 250V/10A Power Cord
  • #6496 - 9-Ft 250V/10A Power Cord
  • #6497 - 6-Ft 250V/15A Power Cord
  • #6498 - 6-Ft 250V/15A Power Cord
  • #6651 - 9-Ft 127V/15A Power Cord
  • #6659 - 9-Ft 240V/15A Power Cord
  • #6660 - 14-Ft 127V/15A Power Cord
  • #6669 - 14-Ft 240V/15A Power Cord
  • #6670 - 6-Ft 125V/15A Power Cord
  • #6680 - 9-Ft 250V/10A Power Cord
  • #6687 - 6-Ft 250V/15A Power Cord
  • Attributes provided: 7 PCI slots and 12 disk positions
  • Attributes required: HSL cable(s) (either copper or optical)
  • For 9405-520: (#5095)
    • Minimum required: 0
    • Maximum allowed: 6 (Initial order maximum: 0)
    • OS level required: i5/OS V5R2, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5096) - PCI-X Exp Tower (no disk)

(No longer available as of May 29, 2009)

#5096 is an I/O expansion tower that has 14 PCI slots. It does not support disk units and does not support any internal removable media devices. A #5088 can not be mounted on a #5096.

One bus adapter to provide the HSL interface to the system is required with each #5096. Select one of the following:

  • #9517 - Base HSL-2 Bus Adapter (to specify two copper HSL-2 ports)
  • #9876 - Base Optical Bus Adapter (to specify two optical HSL ports)

    Note: If ordered for a 9408-M25 or 9409-M50 a #6699 (RIO-2 Bus Adapter) must be ordered instead of a #9517 or #9876.

  • One or two cables must be ordered to attach to the HSL or HSL-2 ports. When ordering cables to connect to the HSL interface, optical HSL, copper HSL, copper HSL-2, or copper HSL to HSL-2 cables are required.
  • An HSL loop uses all optical or all copper ports and cables. A copper loop can intermix I/O towers and units with copper HSL and copper HSL-2 ports. Select the appropriate cable based on the type of HSL ports to which it is being attached, and the cable length required.

The following HSL cables can be used with a #5096:

  • #1307 - 1.75m HSL-2 Cable
  • #1308 - 2.5m HSL-2 Cable
  • #1460 3m HSL Cable
  • #1461 6m HSL Cable
  • #1462 15m HSL Cable
  • #1470 6m HSL Optical Cable (model specific usage)
  • #1471 30m HSL Optical Cable (model specific usage)
  • #1472 100m HSL Optical Cable (model specific usage)
  • #1473 250m HSL Optical Cable (model specific usage)
  • #1464 6m HSL to HSL-2 Cable
  • #1475 10m HSL to HSL-2 Cable
  • #1481 1m HSL-2 Cable
  • #1482 4m HSL-2 Cable
  • #1483 10m HSL-2 Cable

One of the following SPCN cables is required for each #5096:

  • #1463 2m SPCN Cable
  • #1464 6m SPCN Cable
  • #1465 15m SPCN Cable
  • #1466 30m SPCN Cable
  • #0369 100m Optical SPCN Cable (model specific usage)
  • #1468 250m Optical SPCN Cable (model specific usage)
  • #6001 2m SPCN Cable
  • #6006 3m SPCN Cable
  • #6007 15m SPCN Cable
  • #6008 6m SPCN Cable
  • #6029 30m SPCN Cable

No base IOP is included with the #5096. Each #5096 comes with redundant, hot-swap, power supplies. To enable further #5096 redundancy, dual line cord capability for the #5096 is provided by feature #5115. An additional #5096 line cord must be ordered when installing a #5115. Plugging in the second line cord, even if to the same outlet, enables the AC power modules to be redundant.

The following line cords are supported on a #5096:

  • #1399 - 4.3m 300V/16A
  • #1406 - 200V 16A 14-Ft TL Line Cord
  • #1408 - 4.3m 200V/16A Pwr Cd Italy
  • #1409 - 4.3m 200V/16A Pwr Cd AU/NZ
  • #1418 - 4.3m 200V/16A Pwr Cd S Afric
  • #1419 - 4.3m 200V/16A Pwr Cd Israel
  • #1420 - 4.3m 200V/16A Pwr Cd EU/Asia
  • #1421 - 4.3m 200V/16A Pwr Cd CH/DK
  • #1451 - 200V 6-Ft Line Cord
  • #1452 - 200V 14-Ft Line Cord
  • #1453 - 200V 6-Ft Locking Line Cord
  • #1454 - 200V 12A 14-Ft TL Line Cord (U.S. default)
  • #1455 - 200V 6-Ft Wtrtght Line Cord
  • #1456 - 200V 14-Ft Wtrtght Line Cord
  • #1476 - 4.3m 200V/12A Pwr Cd UK
  • Attributes provided: Attributes provided: 14 PCI slots
  • Attributes required: Attributes required: HSL connection (either copper or optical)
  • For 9405-520: (#5096)
    • Minimum required: 0
    • Maximum allowed: 6 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later, AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5108) - 30-Disk Expansion Feature

(No Longer Available as of July 28, 2009)

#5108 is a disk unit expansion enclosure feature for a single line cord #5094 PCI-X Expansion Tower. #5108 includes two 15-disk-unit enclosures, one 765-watt power supply, back-planes, and cables. One PCI Disk Unit Controller is required to support each 15-disk-unit enclosure.

  • Attributes provided: 30 additional disk unit slots
  • Attributes required: #5094 PCI-X Expansion Tower
  • For 9405-520: (#5108)
    • Minimum required: 0
    • Maximum allowed: 6 (Initial order maximum: 6)
    • OS level required: n/a
    • Initial Order/MES/Both/Supported: Both
    • CSU: No

(#5115) - Dual Line Cords - Tower

(No Longer Available as of November 27, 2009)

#5115 is a dual line cord enabler for the upper unit in a #8094 Optional Base 1.8m I/O Rack, and also for the #5094 PCI-X Expansion Tower. #5115 includes an additional power supply. An additional line cord must be specified.

Plugging in the second line cord, even if to the same outlet, enables the AC power modules to be redundant.

  • Attributes provided: Dual line cord capability
  • Attributes required: #8094 or #5094
  • For 9405-520: (#5115)
    • Minimum required: 0
    • Maximum allowed: 6 (Initial order maximum: 6)
    • OS level required: i5/OS V5R2, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5116) - Dual Line Cords - 5294 Tower

(No longer available as of May 29, 2009)

Provides dual line cord capability for a single enclosure in a #5294 tower. Two line cords must be specified for each #5116 ordered with a #5294. When ordering a #5116 for an installed #5294, an additional line cord must be specified for each #5116. The configurator will default two #5116s, for each #5294 ordered with a system that has dual line cords on the system unit.

Plugging in the second line cord, even if to the same outlet, enables the AC power modules to be redundant.

  • Attributes provided: Dual line cord capability for a single unit in a #5294
  • Attributes required: 5294
  • For 9405-520: (#5116)
    • Minimum required: 0
    • Maximum allowed: 6 (Initial order maximum: 6)
    • OS level required: i5/OS V5R2, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5138) - Redundant Power and Cooling

(No Longer Available as of October 2, 2009)

#5138 provides redundant power for the #0595/#5095 PCI-X Expansion Towers. #5138 includes a second 435W power supply, and requires that a second line cord be specified. The second line cord enables dual line cord capability.

  • Attributes provided: Redundant Power
  • Attributes required: #0595/#5095 PCI-X Expansion Tower.
  • For 9405-520: (#5138)
    • Minimum required: 0
    • Maximum allowed: 6 (Initial order maximum: 6)
    • OS level required: i5/OS V5R2, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5158) - 850W AC Power Supply

(No longer available as of July 08, 2008)

The #5158 is an optional 850W power supply which installs in a system unit and provides redundant power.

The #5158 requires an additional CEC line cord feature to be ordered.

  • For 9405-520: (#5158)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5159) - 850 Watt Power Supply

(No longer available as of January 01, 2009)

Provides an optional 850W power supply which installs in a 515, 520, or 525 system unit with processor #8325, #8327, or #8330 and provides redundant power.

The #5159 requires an additional CEC line cord feature to be ordered.

  • Attributes provided: Redundant power supply.
  • Attributes required: Additional CEC line cord
  • For 9405-520: (#5159)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3 with V5R3M5 Machine Code, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE Linux Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

    Requires processor #8325 or #8327.

(#5160) - Power Dist Unit 1 Phase NEMA

(No longer available as of January 15, 2005)

This feature provides a single phase NEMA PDU for iSeries Racks. Each PDU provides six outlets.

System units and/or expansion units would use a #1422 or #6458 line cord to connect to the #5160.

The following line cords are supported on the #5160:

  • #1424 - 200V 6-Ft Locking Line Cord (supported, not orderable)
  • #1425 - 200V 6-Ft Wtrtght Line Cord (supported, not orderable)
  • #1426 - 200V 14-Ft Locking Line Cord
  • #1427 - 200V 14-Ft Wtrtght Line Cord
  • #1446 - 4.3m 200V/30A Pwr Cd Korea
  • #1447 - 4.3m 200V/30A Pwr Cd AU
  • #1448 - 4.3m 200V/30A Pwr Cd NZ (supported, not orderable)
  • Attributes provided: Power Distribution Unit
  • Attributes required: iSeries Rack
  • For 9405-520: (#5160)
    • Minimum required: 0
    • Maximum allowed: 250 (Initial order maximum: 250)
    • OS level required: i5/OS V5R1, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5294) - 1.8m I/O Tower

(No longer available as of May 29, 2009)

The #5294 is a I/O expansion tower that can contain up to 90 disk units, has 28 PCI slots and has four removable media bays.

Each #5294 is essentially two #5094 PCI Expansion Towers, with side covers and casters removed, placed in a 1.8M rack. Each #5294 counts as two #5094s towards the system model maximums.

Two bus adapters, to provide the HSL interfaces to the system, are required with each #5294. Select two of the following (any combination):

  • #9517 - Base HSL-2 Bus Adapter, for copper HSL-2 interfaces
  • #9876 - Base Optical Bus Adapter, for optical HSL interfaces

The upper and lower enclosures (#5094s) in a #5294 are not connected internally by an HSL cable. If the #5294 is to be placed in an HSL loop (both upper and lower enclosure on same HSL loop), an HSL-2 cable is required to connect the upper and lower enclosures. An HSL loop uses all optical or all copper ports/cables. A copper loop can intermix I/O towers/units with copper HSL and copper HSL-2 ports. Select the appropriate cable based on the type of HSL ports to which it is being attached, and the cable length required.

Select three or four (any combination) of the following HSL cables, on first #5094 on system, initial order. For additional #5094s or on an MES, select two, three or four (any combination) HSL cables per tower:

The following HSL cables can be used with a #5294:

  • #1307 1.75m HSL-2 Cable
  • #1308 2.5m HSL-2 Cable
  • #1460 3m HSL Cable
  • #1461 6m HSL Cable
  • #1462 15m HSL Cable
  • #1470 6m HSL Optical Cable (model 570 and 595 only)
  • #1471 30m HSL Optical Cable (model 570 and 595 only)
  • #1472 100m HSL Optical Cable (model 570 and 595 only)
  • #1473 250m HSL Optical Cable (model 570 and 595 only)
  • #1464 6m HSL to HSL-2 Cable
  • #1475 10m HSL to HSL-2 Cable
  • #1481 1m HSL-2 Cable
  • #1482 4m HSL-2 Cable
  • #1483 10m HSL-2 Cable

Select two of the following SPCN cables for each #5294:

  • #1463 2m SPCN Cable
  • #1464 6m SPCN Cable
  • #1465 15m SPCN Cable
  • #1466 30m SPCN Cable
  • #0369 100m Optical SPCN Cable (model 570 only)
  • #1468 250m Optical SPCN Cable (model 570 only)
  • #6001 2m SPCN Cable
  • #6006 3m SPCN Cable
  • #6007 15m SPCN Cable
  • #6008 6m SPCN Cable
  • #6029 30m SPCN Cable

Each #5294 will include two #9844 Base PCI IOPs.

Note: With the availability of V5R4, #9844s are not included with #5294.

For each #5294 ordered, a quantity of two #0694(#5094 Equivalent) specify codes will be added to the order. If a #5294 is to be shared between two systems, one #0694 must be removed from the original ordering system and added to the sharing system, using an RPO(Record Purpose Only) change.

Each of the two tower units within a #5294 fully support 45 disk units (no #5108s need be ordered).

Dual line cord capability is available for the #5294 with feature #5116. With a #5116 installed, both tower units of a #5294 will have dual line cord capability. Two additional line cords (for a total of four) must be ordered when a #5116 is installed. Plugging in the second line cord from the upper and lower units, even if to the same outlet, enables each unit's AC power modules to be redundant. For the best power protection, the first and second line cords should be attached to different power sources.

The following line cords are supported on a #5294 (two line cord features required):

  • #1399 - 4.3m 300V/16A
  • #1406 - 200V 16A 14-Ft TL Line Cord
  • #1408 - 4.3m 200V/16A Pwr Cd Italy
  • #1409 - 4.3m 200V/16A Pwr Cd AU/NZ
  • #1418 - 4.3m 200V/16A Pwr Cd S Afric
  • #1419 - 4.3m 200V/16A Pwr Cd Israel
  • #1420 - 4.3m 200V/16A Pwr Cd EU/Asia
  • #1421 - 4.3m 200V/16A Pwr Cd CH/DK
  • #1451 - 200V 6-Ft Line Cord
  • #1452 - 200V 14-Ft Line Cord
  • #1453 - 200V 6-Ft Locking Line Cord
  • #1454 - 200V 12A 14-Ft TL Line Cord
  • #1455 - 200V 6-Ft Wtrtght Line Cord
  • #1456 - 200V 14-Ft Wtrtght Line Cord
  • #1476 - 4.3m 200V/12A Pwr Cd UK

The 45 disk unit positions in each unit of a #5294, are in groups of 15, each group of 15 disk units is further divided into three groups of five disk units, each group of five disk units supported on a separate SCSI (LVD-SCSI) bus from a #4748/#4778/#2757/#2780/ #5715/#5703 PCI Disk Unit Controller.

The two removable media bays of each unit within a #5294 are supported by the same #4748/#4778/#2757/#2780/#5715/#5703 PCI Disk Unit Controller that supports disk unit positions D31 thru D35) of each internal tower unit.

  • Attributes provided: 28 PCI slots, 90 disk unit positions, four removable media bays
  • Attributes required: HSL connections, two to four wall electrical outlets, at least one #0694 on the inventory records
  • For 9405-520: (#5294)
    • Minimum required: 0
    • Maximum allowed: 3 (Initial order maximum: 3)
    • OS level required: i5/OS V5R2, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5296) - 1.8m I/O Tower (no disk)

(No longer available as of May 29, 2009)

The #5296 is a I/O expansion tower that has 28 PCI slots, no disk unit bays, and no removable media bays.

Each #5296 is essentially two #5096 PCI-X Expansion Towers, with side covers and casters removed, placed in a 1.8M rack. Each #5296 counts as two #5096s towards the system model maximums.

Two bus adapters, to provide the HSL interfaces to the system, are required with each #5296. Select two of the following:

  • #9517 - Base HSL-2 Bus Adapter (for copper HSL-2 interfaces)
  • #9876 - Base Optical Bus Adapter (for optical HSL interfaces)

    Note: If ordered for a 9408-M25 or 9409-M50 a #6699 (RIO-2 Bus Adapter) must be ordered instead of a #9517 or #9876.

The upper and lower enclosures (#5096s) in a #5296 are not connected internally by an HSL cable. If the #5296 is to be placed in an HSL loop (both upper and lower enclosure on same HSL loop), an HSL-2 cable is required to connect the upper and lower enclosures. An HSL loop uses all optical or all copper ports/cables. A copper loop can intermix I/O towers/units with copper HSL and copper HSL-2 ports. Select the appropriate cable based on the type of HSL ports to which it is being attached, and the cable length required.

Select three or four of the following HSL cables, on initial orders, for the first #5296 on the system. For additional #5296s, or on an MES order, select two, three, or four of the following HSL cables per tower:

  • #1307 - 1.75m HSL-2 Cable
  • #1308 - 2.5m HSL-2 Cable
  • #1460 3m HSL Cable
  • #1461 6m HSL Cable
  • #1462 15m HSL Cable
  • #1470 6m HSL Optical Cable (model specific usage)
  • #1471 30m HSL Optical Cable (model specific usagey)
  • #1472 100m HSL Optical Cable (model specific usage)
  • #1473 250m HSL Optical Cable (model specific usage)
  • #1464 6m HSL to HSL-2 Cable
  • #1475 10m HSL to HSL-2 Cable
  • #1481 1m HSL-2 Cable
  • #1482 4m HSL-2 Cable
  • #1483 10m HSL-2 Cable

Select two of the following SPCN cables for each #5296:

  • #1463 2m SPCN Cable
  • #1464 6m SPCN Cable
  • #1465 15m SPCN Cable
  • #1466 30m SPCN Cable
  • #0369 100m Optical SPCN Cable (model specific usage)
  • #1468 250m Optical SPCN Cable (model specific usage)
  • #6001 2m SPCN Cable
  • #6006 3m SPCN Cable
  • #6007 15m SPCN Cable
  • #6008 6m SPCN Cable
  • #6029 30m SPCN Cable

No base IOPs are included with a #5296. For each #5296 ordered, a quantity of two #0694, #5096 Equivalent, specify codes will be added to the order. If a #5296 is to be shared between two systems, one #0694 must be removed from the original ordering system and added to the sharing system, using a Record Purpose Only (RPO) change.

Dual line cord capability is available for the #5296 with feature #5116. With a #5116 installed, both tower units of a #5296 will have dual line cord capability. Two additional line cords (for a total of four), must be ordered when a #5116 is installed. Plugging in the second line cord from the upper and lower units, even if to the same outlet, enables each unit's AC power modules to be redundant. For the best power protection, the first and second line cords should be attached to different power sources.

Two of the following line cords are required on a #5296:

  • #1399 - 4.3m 300V/16A
  • #1406 - 200V 16A 14-Ft TL Line Cord
  • #1408 - 4.3m 200V/16A Pwr Cd Italy
  • #1409 - 4.3m 200V/16A Pwr Cd AU/NZ
  • #1418 - 4.3m 200V/16A Pwr Cd S Afric
  • #1419 - 4.3m 200V/16A Pwr Cd Israel
  • #1420 - 4.3m 200V/16A Pwr Cd EU/Asia
  • #1421 - 4.3m 200V/16A Pwr Cd CH/DK
  • #1451 - 200V 6-Ft Line Cord
  • #1452 - 200V 14-Ft Line Cord
  • #1453 - 200V 6-Ft Locking Line Cord
  • #1454 - 200V 12A 14-Ft TL Line Cord
  • #1455 - 200V 6-Ft Wtrtght Line Cord
  • #1456 - 200V 14-Ft Wtrtght Line Cord
  • #1476 - 4.3m 200V/12A Pwr Cd UK
  • Attributes provided: 28 PCI slots
  • Attributes required: HSL connections, two to four wall electrical outlets, at least one #0696 on the inventory record
  • For 9405-520: (#5296)
    • Minimum required: 0
    • Maximum allowed: 3 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later, AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5540) - Sys Console on Twinax WSC

When #5540 is on the order, the system console is driven by a twinaxial adapter. #4746 PCI Twinaxial Workstation IOA is added to the order:

  • Attributes provided: System Console on a Twinaxial Connection
  • Attributes required: #4746 PCI Twinaxial Worstation IOA
  • For 9405-520: (#5540)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V3R0.5, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5544) - Sys Console on OP Console

When #5544 is on the order, the system console is driven by a WAN adapter. A #0367, Operations Console PCI cable is required on the system/order.

  • Attributes provided: System Console on a WAN Connection
  • Attributes required: WAN IOA, #0367 Operations Console PCI Cable
  • For 9405-520: (#5544)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5546) - Sys Console 100Mbps Tkn-Rng

(No longer available as of June 01, 2006)

With #5546, the system console is driven by a token-ring LAN adapter. #2744, PCI 100Mbps Token-Ring IOA, is required on the server. This LAN adapter must be dedicated to console support/ functions and cannot be used for any other purpose.

  • Attributes provided: System Console on a Token Ring Connection
  • Attributes required: #2744 PCI 100Mbps Token-Ring IOA.
  • For 9405-520: (#5546)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R1, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5548) - Sys Console 100Mbps Ethernet

With #5548, the system console is driven by an Ethernet LAN adapter. Some system unit Ethernet ports are not supported. A 100/ 10Mbps Ethernet IOA is required on the system. This LAN adapter must be dedicated to console support functions and cannot be used for any other purpose.

  • Attributes provided: System Console on a Ethernet Connection
  • Attributes required: a 100/10Mbps Ethernet LAN IOA.
  • For 9405-520: (#5548)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R1, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5550) - Sys Console On HMC

With #5550, system console function is driven by the Hardware Management Console (HMC) connected to the system. The HMC is required if the following functions are desired/selected for the system:

  • Partitioning
  • Capacity Upgrade on Demand
  • Attributes provided: System Console on Hardware Management Console (HMC)
  • Attributes required: Hardware Management Console (HMC)
  • For 9405-520: (#5550)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5552) - Sys Console on Thin Console

(No longer available as of August 26, 2008)

This specify indicates the use of a thin console for the system console. The thin console is attached to an Ethernet port of the system unit's service processor and does not take away an Ethernet port from i5/OS.

  • Attributes provided: System Console connection through the service processor Ethernet port
  • Attributes required: service processor Ethernet port
  • For 9405-520: (#5552)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5553) - Sys Console-Ethernet No IOP

This specify indicates the use of an embedded CEC LAN port for the system console connection using Operations Console (LAN).

  • Attributes provided: System console connection through an embedded CEC LAN port.
  • Attributes required: Embedded CEC LAN port.
  • For 9405-520: (#5553)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3 with V5R3M5 Machine Code, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5554) - Mirror 35GB Disk/Ctlr Pkg

(No longer available as of November 08, 2005)

This feature provides a disk unit controller (#2780 equivalent) and twelve (12) 15k rpm 35GB disk units (#4326 equivalent) for servers doing mirroring. Either #0042 Mirrored System IOP Level or #0043 Mirrored System Bus Level is a prerequisite.

  • Attributes provided: Twelve (12) 35GB mirrored disk units
  • Attributes required: PCI slot for disk controller, 12 disk unit slots and #0042 or #0043.
  • For 9405-520: (#5554)
    • Minimum required: 0
    • Maximum allowed: 23 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5555) - Mirror 70GB Disk/Ctlr Pkg

(No longer available as of January 31, 2008)

This feature provides a disk unit controller (#2780 equivalent) and twelve (12) 15k rpm 70GB disk units (#4327 equivalent) for servers doing mirroring. Either #0042 Mirrored System IOP Level or #0043 Mirrored System Bus Level is a prerequisite.

  • Attributes provided: Twelve (12) 70GB mirrored disk units
  • Attributes required: PCI slot for disk controller, 12 disk unit slots and #0042 or #0043.
  • For 9405-520: (#5555)
    • Minimum required: 0
    • Maximum allowed: 23 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5556) - Mirror 141GB Disk/Ctlr Pkg

(No longer available as of January 31, 2008)

Provides a disk unit controller (#2780 equivalent) and twelve 15k rpm 141GB disk units (#4328 equivalent) for servers doing mirroring. Either #0042 Mirrored System IOP Level or #0043 Mirrored System Bus Level is a prerequisite.

  • Attributes provided: Twelve 141GB mirrored disk units
  • Attributes required: PCI slot for disk controller, twelve disk unit slots and #0042 or #0043.
  • For 9405-520: (#5556)
    • Minimum required: 0
    • Maximum allowed: 23 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5557) - Sys Console-Ethernet No IOP

Indicates that the system console is driven by an IOP-less Ethernet LAN adapter. This LAN adapter must be dedicated to console support functions and cannot be used for any other purpose.

  • Attributes provided: System Console connection through an IOP-less Ethernet LAN adapter
  • Attributes required: PCI-X IOP-less Ethernet LAN Adapter
  • For 9405-520: (#5557)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: i5/OS V5R4, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#5560) - Mirror 35GB Drawer Package

(No longer available as of June 01, 2006)

This package feature includes one #0595 rackmount I/O expansion unit, one #9844 IOP, twelve #4326 35.16GB 15k rpm disk units and two high- function, large write cache disk controllers (#2757 or newer) for servers doing mirroring. The I/O drawer requires five EIA of rack space and has a total of seven PCI-X IOP/IOA slots and 12 disk unit slots. Three PCI-X slots and 12 disk unit slots are filled with the package contents, but four PCI-X slots can be used by other PCI-X IOPs/IOAs.

On IBM ordering, shipping, and inventory documentation, the component features specifically for the #0595 I/O drawer, the disk units, and the disk controllers will not be shown. The chargeable #5560 feature number will be shown and will carry the price and warranty for this package.

Customers should use the specific component features such as #0595 for all planning and implementation documentation. The #0040 Mirrored System Disk Level is a prerequisite.

A bus adapter to provide the HSL interface to the system is required. Select one of the following:

  • #9517 - Base HSL-2 Bus Adapter, to specify two copper HSL-2 ports
  • #9876 - Base Optical Bus Adapter, to specify two optical HSL ports

One or two HSL cables must be ordered with each #5560.

When ordering cables to connect to the HSL interface, optical HSL, copper HSL, copper HSL-2, or copper HSL to HSL-2 cables are required. An HSL loop uses all optical or all copper ports/cables. A copper loop can intermix I/O towers/units with copper HSL and copper HSL-2 ports. Select the appropriate cable based on the type of HSL ports to which it is being attached, and the cable length required.

The following HSL cables can be used with a #5560:

  • Copper HSL to HSL-2 (HSL on one end and HSL-2 on the other end)
    • #1474 - 6m HSL to HSL-2 Cable
    • #1475 - 10m HSL to HSL-2 Cable
    • #1487 - 3m HSL to HSL-2 Cable
  • Copper HSL-2 (HSL-2 on both ends of the cable)
    • #1307 - 1.75m HSL-2 Cable
    • #1308 - 2.5m HSL-2 Cable
    • #1481 - 1.2m HSL-2 Cable
    • #1482 - 3.5m HSL-2 Cable
    • #1483 - 10m HSL-2 Cable
    • #1485 - 15m HSL-2 Cable
  • Optical HSL (optical HSL connections on both ends of the cable)
    • #1470 - 6m HSL Optical Cable
    • #1471 - 30m HSL Optical Cable
    • #1472 - 100m HSL Optical Cable
    • #1473 - 250m HSL Optical Cable

One SPCN cable is required with each #5560. Select one of the following:

  • #1463 - 2m SPCN Cable
  • #1464 - 6m SPCN Cable
  • #1465 - 15m SPCN Cable
  • #1466 - 30m SPCN Cable
  • #0369 - 100m Optical SPCN Cable
  • #1468 - 250m Optical SPCN Cable
  • #6001 - 2m SPCN Cable
  • #6006 - 3m SPCN Cable
  • #6007 - 15m SPCN Cable
  • #6008 - 6m SPCN Cable
  • #6029 - 30m SPCN Cable

The #5560 has redundant power when feature #5138 is installed. The #5138 provides a second 435W power supply. In addition, when a #5138 is installed, a second line cord must be ordered. The presence of the #5138 and the second line cord, enables dual line cord capability.

Select one of the following line cords, or select two if #5138 is ordered:

  • #1394 - 4.3m 200V/10A Pwr Crd Brazil
  • #1395 - 4.3m 200V/10A Pwr Cd China
  • #1397 - 4.3m 200V/10A Pwr Crd Argent
  • #1398 - 4.3m 100V/10A Pwr Crd Brazil
  • #1410 - 200V 6-Ft Line Cord
  • #1411 - 200V 14-Ft Line Cord
  • #1412 - 125V 6-Ft Line Cord
  • #1413 - 125V 14-Ft Line Cord
  • #1414 - 200V 6-Ft Locking Line Cord
  • #1415 - 200V 6-Ft Watertight Line Cord
  • #1416 - 200V 14-Ft Locking Line Cord
  • #1417 - 200V 14-Ft Wtrtght Line Cord
  • #1422 - 3m IEC 320 C13/14 PDU Cord
  • #1438 - 4.3m 200V/10A Pwr Cd AU/NZ
  • #1439 - 4.3m 200V/10A Pwr Cd EU/Asia
  • #1440 - 4.3m 200V/10A Pwr Cd Denmark
  • #1441 - 4.3m 200V/10A Pwr Cd S Africa
  • #1442 - 4.3m 200V/10A Pwr Cd Swiss
  • #1443 - 4.3m 200V/10A Pwr Cd UK
  • #1444 - 4.3m 200V/10A Pwr Cd Italy
  • #1445 - 4.3m 200V/10A Pwr Cd Israel
  • #6458 - 14-Ft Int 250V/10A Pwr Cd
  • #6460 - 14-Ft 125V/15A Power Cord
  • #6469 - 14-Ft 250V/15A Power Cord
  • #6470 - 6-Ft 125V/15A Power Cord
  • #6471 - 9-Ft 125V/15A Power Cord
  • #6472 - 9-Ft 250V/16A Power Cord
  • #6473 - 9-Ft 250V/10A Power Cord
  • #6474 - 9-Ft 250V/13A Power Cord
  • #6475 - 9-Ft 250V/16A Power Cord
  • #6476 - 9-Ft 250V/10A Power Cord
  • #6477 - 9-Ft 250V/10A Power Cord
  • #6478 - 9-Ft 250V/16A Power Cord
  • #6479 - 9-Ft 250V/10A Power Cord
  • #6487 - 6-Ft 250V/15A Power Cord
  • #6488 - 9-Ft Dual Voltage Pwr Cd
  • #6493 - 9-Ft 250V/10A Power Cord
  • #6494 - 9-Ft 250V/10A Power Cord
  • #6495 - 9-Ft 250V/10A Power Cord
  • #6496 - 9-Ft 250V/10A Power Cord
  • #6497 - 6-Ft 250V/15A Power Cord
  • #6498 - 6-Ft 250V/15A Power Cord
  • #6651 - 9-Ft 127V/15A Power Cord
  • #6659 - 9-Ft 240V/15A Power Cord
  • #6660 - 14-Ft 127V/15A Power Cord
  • #6669 - 14-Ft 240V/15A Power Cord
  • #6670 - 6-Ft 125V/15A Power Cord
  • #6680 - 9-Ft 250V/10A Power Cord
  • #6687 - 6-Ft 250V/15A Power Cord
  • Attributes provided: 12 35.16GB disk units and 7 PCI card slots
  • Attributes required: #0040, 5 EIA rack space
  • For 9405-520: (#5560)
    • Minimum required: 0
    • Maximum allowed: 6 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5561) - Mirror 70GB Drawer Package

(No longer available as of June 01, 2006)

This package feature includes one #0595 rackmount I/O expansion unit, one #9844 IOP, twelve #4327 70.56GB 15k rpm disk units and two high- function, large write cache disk controllers (#2757 or newer) for servers doing mirroring. The I/O drawer requires five EIA of rack space and has a total of seven PCI-X IOP/IOA slots and 12 disk unit slots. Three PCI-X slots and 12 disk unit slots are filled with the package contents, but four PCI-X slots can be used by other PCI-X IOPs/IOAs.

On IBM ordering, shipping, and inventory documentation, the component features specifically for the #0595 I/O drawer, the disk units, and the disk controllers will not be shown. The chargeable #5561 feature number will be shown and will carry the price and warranty for this package.

Customers should use the specific component features such as #0595 for all planning and implementation documentation. The #0040 Mirrored System Disk Level is a prerequisite.

A bus adapter to provide the HSL interface to the system is required. Select one of the following:

  • #9517 - Base HSL-2 Bus Adapter, to specify two copper HSL-2 ports
  • #9876 - Base Optical Bus Adapter, to specify two optical HSL ports

One or two HSL cables must be ordered with each #5561.

When ordering cables to connect to the HSL interface, optical HSL, copper HSL, copper HSL-2, or copper HSL to HSL-2 cables are required. An HSL loop uses all optical or all copper ports/cables. A copper loop can intermix I/O towers/units with copper HSL and copper HSL-2 ports. Select the appropriate cable based on the type of HSL ports to which it is being attached, and the cable length required.

The following HSL cables can be used with a #5561:

  • Copper HSL to HSL-2 (HSL on one end and HSL-2 on the other end)
    • #1474 - 6m HSL to HSL-2 Cable
    • #1475 - 10m HSL to HSL-2 Cable
    • #1487 - 3m HSL to HSL-2 Cable
  • Copper HSL-2 (HSL-2 on both ends of the cable)
    • #1307 - 1.75m HSL-2 Cable
    • #1308 - 2.5m HSL-2 Cable
    • #1481 - 1.2m HSL-2 Cable
    • #1482 - 3.5m HSL-2 Cable
    • #1483 - 10m HSL-2 Cable
    • #1485 - 15m HSL-2 Cable
  • Optical HSL (optical HSL connections on both ends of the cable)
    • #1470 - 6m HSL Optical Cable
    • #1471 - 30m HSL Optical Cable
    • #1472 - 100m HSL Optical Cable
    • #1473 - 250m HSL Optical Cable

One SPCN cable is required with each #5561. Select one of the following:

  • #1463 - 2m SPCN Cable
  • #1464 - 6m SPCN Cable
  • #1465 - 15m SPCN Cable
  • #1466 - 30m SPCN Cable
  • #0369 - 100m Optical SPCN Cable
  • #1468 - 250m Optical SPCN Cable
  • #6001 - 2m SPCN Cable
  • #6006 - 3m SPCN Cable
  • #6007 - 15m SPCN Cable
  • #6008 - 6m SPCN Cable
  • #6029 - 30m SPCN Cable

The #5561 has redundant power when feature #5138 is installed. The #5138 provides a second 435W power supply. In addition, when a #5138 is installed, a second line cord must be ordered. The presence of the #5138 and the second line cord, enables dual line cord capability.

Select one of the following line cords, or select two if #5138 is ordered:

  • #1394 - 4.3m 200V/10A Pwr Crd Brazil
  • #1395 - 4.3m 200V/10A Pwr Cd China
  • #1397 - 4.3m 200V/10A Pwr Crd Argent
  • #1398 - 4.3m 100V/10A Pwr Crd Brazil
  • #1410 - 200V 6-Ft Line Cord
  • #1411 - 200V 14-Ft Line Cord
  • #1412 - 125V 6-Ft Line Cord
  • #1413 - 125V 14-Ft Line Cord
  • #1414 - 200V 6-Ft Locking Line Cord
  • #1415 - 200V 6-Ft Watertight Line Cord
  • #1416 - 200V 14-Ft Locking Line Cord
  • #1417 - 200V 14-Ft Wtrtght Line Cord
  • #1422 - 3m IEC 320 C13/14 PDU Cord
  • #1438 - 4.3m 200V/10A Pwr Cd AU/NZ
  • #1439 - 4.3m 200V/10A Pwr Cd EU/Asia
  • #1440 - 4.3m 200V/10A Pwr Cd Denmark
  • #1441 - 4.3m 200V/10A Pwr Cd S Africa
  • #1442 - 4.3m 200V/10A Pwr Cd Swiss
  • #1443 - 4.3m 200V/10A Pwr Cd UK
  • #1444 - 4.3m 200V/10A Pwr Cd Italy
  • #1445 - 4.3m 200V/10A Pwr Cd Israel
  • #6458 - 14-Ft Int 250V/10A Pwr Cd
  • #6460 - 14-Ft 125V/15A Power Cord
  • #6469 - 14-Ft 250V/15A Power Cord
  • #6470 - 6-Ft 125V/15A Power Cord
  • #6471 - 9-Ft 125V/15A Power Cord
  • #6472 - 9-Ft 250V/16A Power Cord
  • #6473 - 9-Ft 250V/10A Power Cord
  • #6474 - 9-Ft 250V/13A Power Cord
  • #6475 - 9-Ft 250V/16A Power Cord
  • #6476 - 9-Ft 250V/10A Power Cord
  • #6477 - 9-Ft 250V/10A Power Cord
  • #6478 - 9-Ft 250V/16A Power Cord
  • #6479 - 9-Ft 250V/10A Power Cord
  • #6487 - 6-Ft 250V/15A Power Cord
  • #6488 - 9-Ft Dual Voltage Pwr Cd
  • #6493 - 9-Ft 250V/10A Power Cord
  • #6494 - 9-Ft 250V/10A Power Cord
  • #6495 - 9-Ft 250V/10A Power Cord
  • #6496 - 9-Ft 250V/10A Power Cord
  • #6497 - 6-Ft 250V/15A Power Cord
  • #6498 - 6-Ft 250V/15A Power Cord
  • #6651 - 9-Ft 127V/15A Power Cord
  • #6659 - 9-Ft 240V/15A Power Cord
  • #6660 - 14-Ft 127V/15A Power Cord
  • #6669 - 14-Ft 240V/15A Power Cord
  • #6670 - 6-Ft 125V/15A Power Cord
  • #6680 - 9-Ft 250V/10A Power Cord
  • #6687 - 6-Ft 250V/15A Power Cord
  • Attributes provided: 12 70.56GB disk units and 7 PCI card slots
  • Attributes required: #0040, 5 EIA of rack space
  • For 9405-520: (#5561)
    • Minimum required: 0
    • Maximum allowed: 6 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5562) - Mirror 35GB Tower Package

(No longer available as of June 01, 2006)

This package feature includes one #5095 tower, one #9844 IOP, twelve #4326 35.16GB 15k rpm disk units and two high-function, large write cache disk controllers (#2757 or newer) for servers doing mirroring. The #5095 has a total of seven PCI-X IOP/IOA slots and 12 disk unit slots. Three PCI-X slots and 12 disk unit slots are filled with the package contents, but four PCI-X slots can be used by other PCI-X IOPs/IOAs.

On IBM ordering, shipping, and inventory documentation, the component features specifically for the #5095 tower, the disk units, and the disk controllers will not be shown. The chargeable #5562 feature number will be shown and will carry the price and warranty for this package.

Customers should use the specific component features such as #5095 for all planning and implementation documentation. The #0040 Mirrored System Disk Level is a prerequisite.

A bus adapter to provide the HSL interface to the system is required. Select one of the following:

  • #9517 - Base HSL-2 Bus Adapter, to specify two copper HSL-2 ports
  • #9876 - Base Optical Bus Adapter, to specify two optical HSL ports

One or two HSL cables must be ordered with each #5562.

When ordering cables to connect to the HSL interface, optical HSL, copper HSL, copper HSL-2, or copper HSL to HSL-2 cables are required. An HSL loop uses all optical or all copper ports/cables. A copper loop can intermix I/O towers/units with copper HSL and copper HSL-2 ports. Select the appropriate cable based on the type of HSL ports to which it is being attached, and the cable length required.

The following HSL cables can be used with a #5562:

  • Copper HSL to HSL-2 (HSL on one end and HSL-2 on the other end)
    • #1474 - 6m HSL to HSL-2 Cable
    • #1475 - 10m HSL to HSL-2 Cable
    • #1487 - 3m HSL to HSL-2 Cable
  • Copper HSL-2 (HSL-2 on both ends of the cable)
    • #1307 - 1.75m HSL-2 Cable
    • #1308 - 2.5m HSL-2 Cable
    • #1481 - 1.2m HSL-2 Cable
    • #1482 - 3.5m HSL-2 Cable
    • #1483 - 10m HSL-2 Cable
    • #1485 - 15m HSL-2 Cable
  • Optical HSL (optical HSL connections on both ends of the cable)
    • #1470 - 6m HSL Optical Cable
    • #1471 - 30m HSL Optical Cable
    • #1472 - 100m HSL Optical Cable
    • #1473 - 250m HSL Optical Cable

One SPCN cable is required with each #5562. Select one of the following:

  • #1463 - 2m SPCN Cable
  • #1464 - 6m SPCN Cable
  • #1465 - 15m SPCN Cable
  • #1466 - 30m SPCN Cable
  • #0369 - 100m Optical SPCN Cable
  • #1468 - 250m Optical SPCN Cable
  • #6001 - 2m SPCN Cable
  • #6006 - 3m SPCN Cable
  • #6007 - 15m SPCN Cable
  • #6008 - 6m SPCN Cable
  • #6029 - 30m SPCN Cable

The #5562 has redundant power when feature #5138 is installed. The #5138 provides a second 435W power supply. In addition, when a #5138 is installed, a second line cord must be ordered. The presence of the #5138 and the second line cord, enables dual line cord capability.

Select one of the following line cords, or select two if #5138 is ordered:

  • #1394 - 4.3m 200V/10A Pwr Crd Brazil
  • #1395 - 4.3m 200V/10A Pwr Cd China
  • #1397 - 4.3m 200V/10A Pwr Crd Argent
  • #1398 - 4.3m 100V/10A Pwr Crd Brazil
  • #1410 - 200V 6-Ft Line Cord
  • #1411 - 200V 14-Ft Line Cord
  • #1412 - 125V 6-Ft Line Cord
  • #1413 - 125V 14-Ft Line Cord
  • #1414 - 200V 6-Ft Locking Line Cord
  • #1415 - 200V 6-Ft Watertight Line Cord
  • #1416 - 200V 14-Ft Locking Line Cord
  • #1417 - 200V 14-Ft Wtrtght Line Cord
  • #1422 - 3m IEC 320 C13/14 PDU Cord
  • #1438 - 4.3m 200V/10A Pwr Cd AU/NZ
  • #1439 - 4.3m 200V/10A Pwr Cd EU/Asia
  • #1440 - 4.3m 200V/10A Pwr Cd Denmark
  • #1441 - 4.3m 200V/10A Pwr Cd S Africa
  • #1442 - 4.3m 200V/10A Pwr Cd Swiss
  • #1443 - 4.3m 200V/10A Pwr Cd UK
  • #1444 - 4.3m 200V/10A Pwr Cd Italy
  • #1445 - 4.3m 200V/10A Pwr Cd Israel
  • #6458 - 14-Ft Int 250V/10A Pwr Cd
  • #6460 - 14-Ft 125V/15A Power Cord
  • #6469 - 14-Ft 250V/15A Power Cord
  • #6470 - 6-Ft 125V/15A Power Cord
  • #6471 - 9-Ft 125V/15A Power Cord
  • #6472 - 9-Ft 250V/16A Power Cord
  • #6473 - 9-Ft 250V/10A Power Cord
  • #6474 - 9-Ft 250V/13A Power Cord
  • #6475 - 9-Ft 250V/16A Power Cord
  • #6476 - 9-Ft 250V/10A Power Cord
  • #6477 - 9-Ft 250V/10A Power Cord
  • #6478 - 9-Ft 250V/16A Power Cord
  • #6479 - 9-Ft 250V/10A Power Cord
  • #6487 - 6-Ft 250V/15A Power Cord
  • #6488 - 9-Ft Dual Voltage Pwr Cd
  • #6493 - 9-Ft 250V/10A Power Cord
  • #6494 - 9-Ft 250V/10A Power Cord
  • #6495 - 9-Ft 250V/10A Power Cord
  • #6496 - 9-Ft 250V/10A Power Cord
  • #6497 - 6-Ft 250V/15A Power Cord
  • #6498 - 6-Ft 250V/15A Power Cord
  • #6651 - 9-Ft 127V/15A Power Cord
  • #6659 - 9-Ft 240V/15A Power Cord
  • #6660 - 14-Ft 127V/15A Power Cord
  • #6669 - 14-Ft 240V/15A Power Cord
  • #6670 - 6-Ft 125V/15A Power Cord
  • #6680 - 9-Ft 250V/10A Power Cord
  • #6687 - 6-Ft 250V/15A Power Cord
  • Attributes provided: 12 35.16GB disk units and 7 PCI card slots
  • Attributes required: #0040
  • For 9405-520: (#5562)
    • Minimum required: 0
    • Maximum allowed: 6 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5563) - Mirror 70GB Tower Package

(No longer available as of June 01, 2006)

This package feature includes one #5095 tower, one #9844 IOP, twelve #4327 70.56GB 15k rpm disk units and two high-function, large write cache disk controllers (#2757 or newer) for servers doing mirroring. The #5095 has a total of seven PCI-X IOP/IOA slots and 12 disk unit slots. Three PCI-X slots and 12 disk unit slots are filled with the package contents, but four PCI-X slots can be used by other PCI-X IOPs/IOAs.

On IBM ordering, shipping, and inventory documentation, the component features specifically for the #5095 tower, the disk units, and the disk controllers will not be shown. The chargeable #5563 feature number will be shown and will carry the price and warranty for this package.

Customers should use the specific component features such as #5095 for all planning and implementation documentation. The #0040 Mirrored System Disk Level is a prerequisite.

A bus adapter to provide the HSL interface to the system is required. Select one of the following:

  • #9517 - Base HSL-2 Bus Adapter, to specify two copper HSL-2 ports
  • #9876 - Base Optical Bus Adapter, to specify two optical HSL ports

One or two HSL cables must be ordered with each #5563.

When ordering cables to connect to the HSL interface, optical HSL, copper HSL, copper HSL-2, or copper HSL to HSL-2 cables are required. n HSL loop uses all optical or all copper ports/cables. A copper loop can intermix I/O towers/units with copper HSL and copper HSL-2 ports. Select the appropriate cable based on the type of HSL ports to which it is being attached, and the cable length required.

The following HSL cables can be used with a #5563:

  • Copper HSL to HSL-2 (HSL on one end and HSL-2 on the other end)
    • #1474 - 6m HSL to HSL-2 Cable
    • #1475 - 10m HSL to HSL-2 Cable
    • #1487 - 3m HSL to HSL-2 Cable
  • Copper HSL-2 (HSL-2 on both ends of the cable)
    • #1307 - 1.75m HSL-2 Cable
    • #1308 - 2.5m HSL-2 Cable
    • #1481 - 1.2m HSL-2 Cable
    • #1482 - 3.5m HSL-2 Cable
    • #1483 - 10m HSL-2 Cable
    • #1485 - 15m HSL-2 Cable
  • Optical HSL (optical HSL connections on both ends of the cable)
    • #1470 - 6m HSL Optical Cable
    • #1471 - 30m HSL Optical Cable
    • #1472 - 100m HSL Optical Cable
    • #1473 - 250m HSL Optical Cable

One SPCN cable is required with each #5563. Select one of the following:

  • #1463 - 2m SPCN Cable
  • #1464 - 6m SPCN Cable
  • #1465 - 15m SPCN Cable
  • #1466 - 30m SPCN Cable
  • #0369 - 100m Optical SPCN Cable
  • #1468 - 250m Optical SPCN Cable
  • #6001 - 2m SPCN Cable
  • #6006 - 3m SPCN Cable
  • #6007 - 15m SPCN Cable
  • #6008 - 6m SPCN Cable
  • #6029 - 30m SPCN Cable

The #5563 has redundant power when feature #5138 is installed. The #5138 provides a second 435W power supply. In addition, when a #5138 is installed, a second line cord must be ordered. The presence of the #5138 and the second line cord, enables dual line cord capability.

Select one of the following line cords, or select two if #5138 is ordered:

  • #1394 - 4.3m 200V/10A Pwr Crd Brazil
  • #1395 - 4.3m 200V/10A Pwr Cd China
  • #1397 - 4.3m 200V/10A Pwr Crd Argent
  • #1398 - 4.3m 100V/10A Pwr Crd Brazil
  • #1410 - 200V 6-Ft Line Cord
  • #1411 - 200V 14-Ft Line Cord
  • #1412 - 125V 6-Ft Line Cord
  • #1413 - 125V 14-Ft Line Cord
  • #1414 - 200V 6-Ft Locking Line Cord
  • #1415 - 200V 6-Ft Watertight Line Cord
  • #1416 - 200V 14-Ft Locking Line Cord
  • #1417 - 200V 14-Ft Wtrtght Line Cord
  • #1422 - 3m IEC 320 C13/14 PDU Cord
  • #1438 - 4.3m 200V/10A Pwr Cd AU/NZ
  • #1439 - 4.3m 200V/10A Pwr Cd EU/Asia
  • #1440 - 4.3m 200V/10A Pwr Cd Denmark
  • #1441 - 4.3m 200V/10A Pwr Cd S Africa
  • #1442 - 4.3m 200V/10A Pwr Cd Swiss
  • #1443 - 4.3m 200V/10A Pwr Cd UK
  • #1444 - 4.3m 200V/10A Pwr Cd Italy
  • #1445 - 4.3m 200V/10A Pwr Cd Israel
  • #6458 - 14-Ft Int 250V/10A Pwr Cd
  • #6460 - 14-Ft 125V/15A Power Cord
  • #6469 - 14-Ft 250V/15A Power Cord
  • #6470 - 6-Ft 125V/15A Power Cord
  • #6471 - 9-Ft 125V/15A Power Cord
  • #6472 - 9-Ft 250V/16A Power Cord
  • #6473 - 9-Ft 250V/10A Power Cord
  • #6474 - 9-Ft 250V/13A Power Cord
  • #6475 - 9-Ft 250V/16A Power Cord
  • #6476 - 9-Ft 250V/10A Power Cord
  • #6477 - 9-Ft 250V/10A Power Cord
  • #6478 - 9-Ft 250V/16A Power Cord
  • #6479 - 9-Ft 250V/10A Power Cord
  • #6487 - 6-Ft 250V/15A Power Cord
  • #6488 - 9-Ft Dual Voltage Pwr Cd
  • #6493 - 9-Ft 250V/10A Power Cord
  • #6494 - 9-Ft 250V/10A Power Cord
  • #6495 - 9-Ft 250V/10A Power Cord
  • #6496 - 9-Ft 250V/10A Power Cord
  • #6497 - 6-Ft 250V/15A Power Cord
  • #6498 - 6-Ft 250V/15A Power Cord
  • #6651 - 9-Ft 127V/15A Power Cord
  • #6659 - 9-Ft 240V/15A Power Cord
  • #6660 - 14-Ft 127V/15A Power Cord
  • #6669 - 14-Ft 240V/15A Power Cord
  • #6670 - 6-Ft 125V/15A Power Cord
  • #6680 - 9-Ft 250V/10A Power Cord
  • #6687 - 6-Ft 250V/15A Power Cord
  • Attributes provided: 12 70.56GB disk units and 7 PCI card slots
  • Attributes required: #0040
  • For 9405-520: (#5563)
    • Minimum required: 0
    • Maximum allowed: 6 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5570) - 5727 Cache + 2 70GB Disk Pkg

(No longer available as of January 01, 2009)

This package provides one #5727 Integrated Cache - 40MB and two #4327 15k rpm 70.56GB Disk Units.

#5727 provides 40MB write cache for the imbedded disk controller in the 515, 520, 525 and also enables RAID-5 capability. The 5727 is installed in its own specific internal slot of the system unit and does not require a PCI slot.

On IBM ordering, shipping, and inventory documentation, the component features specifically for the #5727 and #4327 disk units will not be shown. The chargeable #5570 feature number will be shown and will carry the price and warranty for this package.

  • Attributes provided: 40MB write cache, RAID-5 data protection for system unit disk drives, and two 70GB disk drives
  • Attributes required: Unused write cache slot in the system unit and two unused disk slots.
  • For 9405-520: (#5570)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5571) - 5727 Cache + 6 70GB Disk Pkg

(No longer available as of January 01, 2009)

This package provides one #5727 Integrated Cache - 40MB and six #4327 15k rpm 70.56GB Disk Units.

The #5727 provides 40MB write cache for the imbedded disk controller in the 515, 520, 525 and also enables RAID-5 capability. The 5727 is installed in its own specific internal slot of the system unit and does not require a PCI slot.

On IBM ordering, shipping, and inventory documentation, the component features specifically for the #5727 and #4327 disk units will not be shown. The chargeable #5571 feature number will be shown and will carry the price and warranty for this package.

  • Attributes provided: 40MB write cache, RAID-5 data protection for system unit disk drives, and six 70GB disk drives
  • Attributes required: Unused write cache slot in the system unit and six unused disk slots. The model 515 has 5592 as a prerequisite.
  • For 9405-520: (#5571)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5580) - 2780 Ctlr w/Aux Write Cache

(No longer available as of July 13, 2007)

Provides a disk controller with auxiliary write cache to improve cache data redundancy. The #5580 includes a #2780 PCI-X Ultra4 RAID Disk Controller and a secondary IOA with 757MB of auxiliary maximum compressed write cache. The #2780 and the secondary IOA each require one PCI-X slot and must be installed together in the same CEC or I/O unit/drawer/tower. The #2780 and the auxiliary write cache IOA are connected by a SCSI cable (provided). Feature #2780 will not appear on IBM ordering, shipping, or inventory documentation.

The connecting SCSI cable is attached to port four of the #2780, reducing the number of SCSI buses that support disk drives from four to three. The reduction of SCSI buses may also reduce the number of disk drives supported by the #2780, depending on the CEC or I/O unit/ drawer/tower in which the #2780 is installed. No disk drives are driven by the auxiliary write cache IOA.

  • Attributes provided: Disk Controller with auxiliary write cache
  • Attributes required: Two PCI-X slots within the same CEC or I/O unit/drawer/tower
  • For 9405-520: (#5580)
    • Minimum required: 0
    • Maximum allowed: 18 (Initial order maximum: 0)
    • OS level required: i5/OS V5R2, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

    #5580 can not be installed in the model 520 CEC.

(#5581) - 2757 Ctlr w/Aux Write Cache

(No longer available as of February 06, 2007)

Provides a disk controller with auxiliary write cache to improve cache data redundancy. The #5581 includes a #2757 PCI-X Ultra4 RAID Disk Controller and a secondary IOA with 757MB of auxiliary maximum compressed write cache. The #2757 and the secondary IOA each require one PCI-X slot and must be installed together in the same CEC or I/O unit/drawer/tower. The #2757 and the auxiliary write cache IOA are connected by a SCSI cable (provided). Feature #2757 will not appear on IBM ordering, shipping, or inventory documentation.

The connecting SCSI cable is attached to port four of the #2757, reducing the number of SCSI buses that support disk drives from four to three. The reduction of SCSI buses may also reduce the number of disk drives supported by the #2757, depending on the CEC or I/O unit/ drawer/tower in which the #2757 is installed. No disk drives are driven by the auxiliary write cache IOA.

  • Attributes provided: Disk Controller with auxiliary write cache
  • Attributes required: Two PCI-X slots within the same CEC or I/O unit/drawer/tower
  • For 9405-520: (#5581)
    • Minimum required: 0
    • Maximum allowed: 18 (Initial order maximum: 0)
    • OS level required: i5/OS V5R2, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

    #5581 can not be installed in the model 520 CEC.

(#5582) - 5738 Ctlr w/Aux Write Cache

Provides a disk controller with auxiliary write cache to improve cache data redundancy. #5582 includes a #5738 PCI-X RAID disk controller and an auxiliary write cache IOA with a maximum compressed write cache of 1.5GB. #5738 and the auxiliary IOA each require one PCI-X slot and must be installed together in the same system unit or I/O unit/drawer/tower. #5738 and the auxiliary write cache IOA are connected by a SCSI cable (provided). Feature #5738 will not appear on IBM ordering, shipping, or inventory documentation.

The connecting SCSI cable is attached to port four of the #5738, reducing the number of SCSI buses that support disk drives from four to three. The reduction of SCSI buses may also reduce the number of disk drives supported by the #5738, depending on the system unit or I/O unit/drawer/tower in which the #5738 is installed. No disk drives are driven by the auxiliary write cache IOA.

#5582 and #5583 are physically the same adapter cards but have different feature numbers that denote to IBM configurator tools whether or not an IOP is required. #5582 indicates an IOP is used.

  • Attributes provided: Disk controller with auxiliary write cache
  • Attributes required: IOP and two PCI-X slots within the same system unit or I/O unit/ drawer/tower
  • For 9405-520: (#5582)
    • Minimum required: 0
    • Maximum allowed: 18 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later.
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

    #5582 can not be installed in the model 520 CEC.

(#5583) - 5777 Ctlr w/Aux Write Cache

Provides a disk controller with auxiliary write cache to improve cache data redundancy. The #5583 includes a #5777 PCI-X disk controller and a secondary IOA with 1.5GB of auxiliary maximum compressed write cache. #5777 and the secondary IOA each require one PCI-X slot and must be installed together in the same system unit or I/O unit/drawer/tower. The #5777 and the auxiliary write cache IOA are connected by a SCSI cable (provided). Feature #5777 will not appear on IBM ordering, shipping, or inventory documentation.

The connecting SCSI cable is attached to port four of the #5777, reducing the number of SCSI buses that support disk drives from four to three. The reduction of SCSI buses may also reduce the number of disk drives supported by the #5777, depending on the system unit or I/O unit/drawer/tower in which the #5777 is installed. No disk drives are driven by the auxiliary write cache IOA.

#5583 and #5582 are physically the same adapter cards but have different feature numbers that denote to IBM configurator tools whether or not an IOP is required. #5583 does not require an IOP.

  • Attributes provided: Disk controller with auxiliary write cache
  • Attributes required: Two PCI-X slots within the same system unit or I/O unit/drawer/tower
  • For 9405-520: (#5583)
    • Minimum required: 0
    • Maximum allowed: 18 (Initial order maximum: 0)
    • OS level required: i5/OS V5R4, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

    #5583 can not be installed in the model 520 CEC.

(#5590) - 2780 Ctlr w/Aux Write Cache

(No longer available as of May 01, 2008)

Provides a disk controller with auxiliary write cache to improve cache data redundancy. #5590 includes a #2780 PCI-X RAID Disk Controller with 757MB of write cache and a secondary IOA with 1.5GB of auxiliary maximum compressed write cache. The #2780 and the secondary IOA each require one PCI-X slot and must be installed together in the same system unit or I/O unit/drawer/tower. #2780 and the auxiliary write cache IOA are connected by the provided SCSI cable. Feature #2780 will not appear on IBM ordering, shipping, or inventory documentation.

The connecting SCSI cable is attached to port four of the #2780, reducing the number of SCSI buses that support disk drives from four to three. The reduction of SCSI buses may also reduce the number of disk drives supported by the #2780, depending on the system unit or I/O unit/drawer/tower in which the #2780 is installed. No disk drives are driven by the auxiliary write cache IOA.

  • Attributes provided: Disk Controller with auxiliary write cache
  • Attributes required: Two PCI-X slots within the same system unit or I/O unit/drawer/tower
  • For 9405-520: (#5590)
    • Minimum required: 0
    • Maximum allowed: 18 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

    #5590 can not be installed in the model 520 CEC.

(#5591) - 2757 Ctlr w/Aux Write Cache

(No longer available as of February 06, 2007)

Provides a disk controller with auxiliary write cache to improve cache data redundancy. The #5591 includes a #2757 PCI-X RAID Disk Controller with a 757MB write cache and a secondary IOA with 1.5GB of auxiliary maximum compressed write cache. The #2757 and the secondary IOA each require one PCI-X slot and must be installed together in the same system unit or I/O unit/drawer/tower. The #2757 and the auxiliary write cache IOA are connected by a SCSI cable (provided). Feature #2757 will not appear on IBM ordering, shipping, or inventory documentation.

The connecting SCSI cable is attached to port four of the #2757, reducing the number of SCSI buses that support disk drives from four to three. The reduction of SCSI buses may also reduce the number of disk drives supported by the #2757, depending on the system unit or I/O unit/drawer/tower in which the #2757 is installed. No disk drives are driven by the auxiliary write cache IOA.

  • Attributes provided: Disk Controller with auxiliary write cache
  • Attributes required: Two PCI-X slots within the same system unit or I/O unit/drawer/tower
  • For 9405-520: (#5591)
    • Minimum required: 0
    • Maximum allowed: 18 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

    #5591 can not be installed in the model 520 CEC.

(#5647) - PCIe Blind Swap Cassette Std

This feature contains a blind swap cassette for one, single width PCI Express adapter or PCI-X adapter that will be mounted in a Standard Length PCI slot. It includes the necessary hardware to mount various sizes of single width PCI adapters that may be less than standard size.

  • Attributes provided: Standard blind swap cassette
  • Attributes required: Standard PCIe card
  • For 9405-520: (#5647)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 0)
    • OS level required: None
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#5700) - PCI 1Gbps Ethernet IOA

(No longer available as of May 29, 2009)

The #5700 is a PCI-X IOA that allows an iSeries server to attach to IEEE standard 802.3Z high speed (1Gbps) Ethernet LANs. A #5700 can also be used to connect to existing 100/10Mbps Ethernet LANs. This adapter supports a multimode fiber interface with a 62.5 micron or 50.0 micron cable requirement. The adapter has a duplex LC fiber-optic connector for attachment to customer-supplied cabling.

The #5700s only supports TCP/IP, and requires an intervening switch/hub/router when connection to 1Gbps or 100/10Mbps networks.

A #5700 is supported by a #2892 or #4810 Integrated xSeries Server.

  • If a #5700 will be controlled/driven by a #2792 or #4810, then specify code #0226 (1Gbps Ethernet Specify) must be ordered. One #0226 for each #5700 controlled/driven by an integrated server.

    #5700, #0620 and #6800 are physically the same adapter card but have different feature numbers to indicate to IBM configurator tools that an IOP is or is not being used in the configuration.

  • Attributes provided: 1000/100/10 Ethernet LAN Interface
  • Attributes required: One short or long, 3.3V or 5V PCI-X slot
  • For 9405-520: (#5700)
    • Minimum required: 0
    • Maximum allowed: 36 (Initial order maximum: 36)
    • OS level required: i5/OS V5R2, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5701) - PCI 1Gbps Ethernet UTP IOA

(No longer available as of May 29, 2009)

#5701 provides PCI-X attachment to IEEE standard 802.3ab high-speed (1Gbps) Ethernet LANs. It can also be used to connect to existing 10Mbps or 100Mbps Ethernet LANs using switches with 10/100/ 1000Mbps ports. The adapter supports a UTP CAT 5 media interface, and only TCP/IP.

If #5701 is used with a #2792 or #2892, then one specify code #0226, 1Gbps Ethernet Specify, must be ordered for each #5701.

#6800 and #5700 are physically the same adapter card but have different feature numbers to indicate to IBM configurator tools that an IOP is or is not being used in the configuration.

#5701, #0621 and #6801 are physically the same adapter card but have different feature numbers to indicate to IBM configurator tools that an IOP is or is not being used in the configuration.

  • Attributes provided: 1000/100/10 Ethernet LAN Interface
  • Attributes required: One short or long, 3.3V or 5V PCI-X slot
  • For 9405-520: (#5701)
    • Minimum required: 0
    • Maximum allowed: 36 (Initial order maximum: 36)
    • OS level required: i5/OS V5R2, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5703) - PCI-X RAID Disk Unit Ctlr

(No longer available as of June 01, 2006)

The #5703 is a SCSI RAID controller that has a 40MB cache and provides RAID-5 protection of internal disks. It also supports internal tape units, CD-ROM, DVD-RAM, and DVD-ROM units.

The #5703 has two SCSI (VHDCI) buses.

In addition to providing RAID-5 protection for disks, #5703 also works as a high-performance controller for disks protected by system mirroring or disks with no protection.

The #5703 supports a maximum of 12 disk units (this total may be limited due to other expansion tower constraints).

A minimum of three disk units of the same capacity are needed for a valid RAID-5 set. A maximum of four arrays are allowed per controller. All disk units in an array must be of the same capacity.

Parity is spread across either two, four, or eight disk units in an array. If an array of three disk units is started, parity is spread across two disk units. If an array of four to seven disk units is started, parity is spread across four disk units. If an array of 8-12 disk units is started, parity is spread across eight disk units.

The number of arrays and size of each array can be influenced by specifying an optimization of either balance, performance, or capacity in Operations Navigator when starting arrays. An optimization of balance is the default when starting arrays from green screens. If disk units are in cluded into an existing array, parity may be spread across less than the preferred number of disk units. In this case the RAID function must be stopped and then started to redistribute the parity.

A #5703 can control up to two removable media devices (internal tape, CD-ROM, DVD-RAM, and DVD-ROM).

  • Attributes provided: Two SCSI VHDCI ports
  • Attributes required: One 3V long PCI slot
  • For 9405-520: (#5703)
    • Minimum required: 0
    • Maximum allowed: 57 (Initial order maximum: 57)
    • OS level required: i5/OS V5R2, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5704) - PCI-X Fibre Chan Tape Ctlr

(No longer available as of June 01, 2006)

Provides Fibre Channel attachment for external tape devices. #5704 supports point-to-point and arbitrated loop topologies and has an LC-type cable connector. Each #5704 is shipped with a wrap connector (P/N 05N6767).

The following adapter kits are required when connecting SC type cables to the #5704:

  • #0371 -- LC-SC Adapter Kit (50um) can be ordered, both on initial, model upgrades, and simple MES orders. This optional kit is used to attach SC-type 50 micron fiber cables to a #5704. This kit contains a 2m LC-ST cable and ST-SC adapter for 50 micron fiber cables.
  • #0372 -- LC-SC Adapter Kit (62.5um) can be ordered, both on initial, model upgrades, and simple MES orders. This optional kit is used to attach SC-type 62.5 micron fiber cables to a #5704. This kit contains a 2m LC-ST cable and ST-SC adapter for 62.5 micron fiber cables.

An optics cleaning kit (P/N 46G6844) and instruction sheet (P/N 21P6238, SY27-2604) is shipped with the #5704. The customer supplies all Fibre Channel cables for this controller.

  • For 9405-520: (#5704)
    • Minimum required: 0
    • Maximum allowed: 36 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5706) - PCI-X 1Gbps Ethernet-TX IOA

The #5706 is a 2-port 1000/100/10Mbps Base-TX Ethernet PCI-X Adapter. The #5706 is a Full Duplex, dual ported, Gigabit Ethernet adapter designed with highly integrated components. This adapter can be configured to run either port at 1000, 100, or 10 Mbps data rate. This adapter interfaces to the system via a PCI or PCI-X bus and connects to a network using a 4-pair CAT-5 Unshielded Twisted Pair (UTP) cable for distances of up to 100m. The adapter conforms to the IEEE 802.3ab 1000Base-T standard. The #5706 also supports jumbo frames when running at the 1000 Mbps speed.

i5/OS does not support a #5706 function called 'Large Send' or sometimes known as TCP Segmentation. This function offloads the TCP segmentation operation from the IP layer to the adapter for outgoing (transmit side) TCP segments.

i5/OS does not support a #5706 function known as "Checksum Offload," which offloads the TCP/UDP Checksum Operation or workload from the CPU to the adapter.

The #5706 does not support SNA.

The #5706 does not require a PCI IOP, even in an i5/OS partition.

Note: For optimum performance, the adapter should be placed in a 64 bit PCI-X card slot whenever possible.

Limitations: The 1000 Mbps speed is not supported in Half Duplex (HDX) mode.

  • Attributes provided: Two full-duplex 1000/100/10Base-TX UTP connections to Gigabit Ethernet LANs.
  • Attributes required: One 3 volt PCI or PCI-X card slot (either long or short)
  • For 9405-520: (#5706)
    • Minimum required: 0
    • Maximum allowed: 17 (Initial order maximum: 17)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5707) - PCI-X 1Gbps Ethernet-SX IOA

(No longer available as of May 29, 2009)

The #5707 is a 2-Port Gigabit Ethernet-SX PCI-X Adapter that provides two 1Gbps (1000 Base-SX) full-duplex Ethernet LAN connections with throughput on a standard shortwave multimode optical cable that conforms to the IEEE 802.3z standard. The adapter supports distances of 260m for 62.5 micron Multi Mode Fiber (MMF) and 550m for 50.0 micron MMF.

i5/OS does not support a #5707 function called 'Large Send' or sometimes known as TCP Segmentation. This function offloads the TCP segmentation operation from the IP layer to the adapter for outgoing (transmit side) TCP segments.

i5/OS does not support a #5707 function known as "Checksum Offload," which offloads the TCP/UDP Checksum Operation or workload from the CPU to the adapter.

The #5707 does not support SNA.

#5707 does not require a PCI IOP, even in an OS/400 partition.

Note: For optimum performance, the adapter should be placed in a 64 bit PCI-X card slot whenever possible.

Note: The 2-Port IBM Gigabit Ethernet-SX PCI-X Adapter incorporates an LC type connector on the card.

Limitation: Half Duplex (HDX) mode is not supported.

  • Attributes provided: Two full-duplex 1000Base-SX fiber connections to a Gigabit Ethernet LANs.
  • Attributes required: One 3V PCI or PCI-X card slot (either short or long)
  • For 9405-520: (#5707)
    • Minimum required: 0
    • Maximum allowed: 17 (Initial order maximum: 17)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5709) - RAID Enabler Card

(No longer available as of June 01, 2006)

#5709 is a SCSI RAID controller which is installed into its own specific internal slot of a system unit and does not require a PCI slot. It functionally replaces the base integrated disk controller, adding RAID functionality and 16MB disk controller cache.

A minimum of three disk units is required for a RAID disk array.

  • Attributes provided: RAID Data Protection for system unit DASD
  • Attributes required: Unused RAID controller slot in a system unit.
  • For 9405-520: (#5709)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

    #5709 is optional in the model 520 system unit and supports up to eight disk units when #6574, 4-Disk Slot Expansion - Base Controller, is installed; up to four disk units when it is not installed.

(#5712) - PCI-X Tape Controller

(No longer available as of June 01, 2006)

The #5712 provides SCSI Ultra-320 PCI attachment capability for up to two external tape/CD/DVD devices.

The #5712 connector ports are 68-pin VHDCI. A #1850 VHDCI to P Converter Cable is available to connect external SCSI devices with P style connectors.

  • Attributes provided: Support/connectivity of up to two external tape/CD/DVD devices
  • Attributes required: One 3V PCI card slot (either long or short)
  • For 9405-520: (#5712)
    • Minimum required: 0
    • Maximum allowed: 57 (Initial order maximum: 57)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5713) - PCI-X 1Gbps iSCSI TOE-Copper

(No longer available as of October 01, 2006)

Provides a 1Gbps iSCSI TOE PCI-X adapter which encapsulates SCSI Commands and data into TCP and transports them over the Ethernet via IP packets. The adapter operates as an iSCSI TOE (TCP/IP Offload Engine). This offload of the host eliminates protocol processing and reduces CPU interrupts. The adapter uses RJ45 1Gbps Ethernet connector.

This iSCSI adapter can be used to initiate requests to external storage devices from AIX 5L and Linux partitions.

  • Attributes provided: Offload of host protocol processing
  • Attributes required: Available PCI-X Slot
  • For 9405-520: (#5713)
    • Minimum required: 0
    • Maximum allowed: 15 (Initial order maximum: 0)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5714) - PCI-X 1Gbps iSCSI TOE-Optic

(No longer available as of October 01, 2006)

Provides a 1Gbps iSCSI TOE PCI-X adapter which encapsulates SCSI Commands and data into TCP and transports them over the Ethernet via IP packets. The adapter operates as an iSCSI TOE (TCP/IP Offload Engine). This offload of the host eliminates protocol processing and reduces CPU interrupts. The adapter uses small form factor LC type fiber optic connector.

This iSCSI adapter can be used to initiate requests to external storage devices from AIX 5L and Linux partitions.

  • Attributes provided: Offload of host protocol processing
  • Attributes required: Available PCI-X Slot
  • For 9405-520: (#5714)
    • Minimum required: 0
    • Maximum allowed: 15 (Initial order maximum: 0)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5715) - PCI-X Tape/DASD Controller

(No longer available as of June 01, 2006)

#5715 provides one SCSI port for external removable media devices, and one SCSI port for up to six internal disk units. RAID protection is not supported. If two external removable media devices need to be supported, a #5712 should be ordered.

  • Attributes provided: Support for up to six disk units and one external tape/CD/DVD device
  • Attributes required: One 3V PCI card slot (either long or short)
  • For 9405-520: (#5715)
    • Minimum required: 0
    • Maximum allowed: 55 (Initial order maximum: 55)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

    #5715 can be installed in #0595/#5094/#5095/#5294 expansion units and in the Model 520 system unit.

(#5718) - 10Gbps Ethernet IOA (Short)

(No longer available as of June 01, 2006)

Provides 10 Gigabit Ethernet PCI-X based server connections. Supports distances of up to 33m using 62.5 um multimode fiber or 300m using 50 um multimode fiber with 2000MHz km minimum model bandwidth at 850 nm. Adapter connector type is LC.

  • Attributes provided: Provides high-end bandwidth for networking
  • Attributes required: Supported in PCI-X slots only
  • For 9405-520: (#5718)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: AIX 5L for Power V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5719) - 10Gbps Ethernet IOA (Long)

(No longer available as of June 01, 2006)

Ten Gigabit Ethernet PCI-X based server connections over a maximum of 10 kilometers of 1310nm single-mode fiber optic cable. The adapter conforms to the IEEE 802.3ae standard. The adapter requires 9um single- mode fiber optic cables and uses a SC connector type for connecting into network infrastructure components like 10 Gigabit Ethernet switch/router with SC connectors.

  • Attributes provided: 10 Gigabit Ethernet connections
  • Attributes required: Available PCI-X slot
  • For 9405-520: (#5719)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5721) - PCI-X 10Gbps Ethernet-SR IOA

(No Longer Available as of November 27, 2009)

Provides 10Gbps Ethernet server connection using a PCI-X DDR IOA. Supports distances of up to 33m using 62.5um multimode fiber or 300m using 50um multimode fiber with 2000MHz km minimum model bandwidth at 850nm. Adapter connector type is LC.

#5721 does not support SNA. #5721 is a smart IOA and operates only in IOP-less mode, even when used by i5/OS.

  • Attributes provided: 10Gbps Ethernet connection
  • Attributes required: Available PCI-X slot. However, for improved bandwidth plug into PCI-X 2.0 DDR slot
  • For 9405-520: (#5721)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 0)
    • OS level required: i5/OS V5R4, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 4, or later, SUSE Linux Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#5722) - PCI-X 10Gbps Ethernet-LR IOA

(No longer available as of July 08, 2008)

Provides 10Gbps Ethernet server connection using a PCI-X DDR IOA. Supports distances of up to 10 kilometers of 1310nm 9um single-mode fiber optic cable. #5722 conforms to the IEEE 802.3ae standard. #5722 requires 9um single-mode fiber optic cables and uses an SC connector type for connecting into network infrastructure components like 10Gbps Ethernet switch/router with SC connectors.

#5722 does not support SNA. #5722 is a smart IOA and operates only in IOP-less mode, even when used by i5/OS.

  • Attributes provided: 10Gbps Ethernet connection
  • Attributes required: Available PCI-X slot, however, for improved bandwidth plug into PCI-X 2.0 DDR slot
  • For 9405-520: (#5722)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 0)
    • OS level required: i5/OS V5R4, or later, AIX 5L for Power V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 4, or later, SUSE Linux Enterprise Server 9 for POWER or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5723) - 2-Port Async EIA-232 PCI IOA

(No Longer Available as of November 27, 2009)

#5723 provides connection for two Asynchronous EIA-232 devices. Ports are programmable to support EIA-232 protocols at a line speed of 128Kbps.

  • Attributes provided: Two Asynchronous Ports
  • Attributes required: One PCI Slot
  • For 9405-520: (#5723)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5727) - Integrated Cache - 40MB

(No Longer Available as of August 28, 2009)

Provides a card that augments the base integrated disk controller of the model 515, 520, 525, or the model 550 with 40MB of write cache and also enables RAID-5 capability for the internal disk drives of the system unit. This feature is functionally equivalent to #5709 but can run in IOP-less mode. #5727 is installed into its own specific internal slot of a system unit and does not require a PCI slot.

A minimum of three disk units are required for a RAID-5 disk array.

  • Attributes provided: 40MB write cache and RAID-5 data protection for system unit disk drives
  • Attributes required: Unused write cache/RAID controller slot in the system unit.
  • For 9405-520: (#5727)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE Linux Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#5736) - PCI-X Disk/Tape Ctlr w/IOP

(No Longer Available as of July 11, 2014)

Provides a PCI-X Disk/Tape SCSI Controller with zero write cache and without RAID support. Disk mirroring support is supported through i5/OS. A maximum of six disk drives are supported on the #5736. Removable media devices (tape, optical libraries, CD-ROM, DVD-ROM, or DVD-RAM) are also supported on the #5736.

The #5736 has two U320 buses each with a bus data rate of up to 320MBs. Each SCSI bus can be either internal (using an internal port) or external (using an external port), but not both. There are four physical ports on the #5736, two internal and two external.

Internal devices connect to the internal ports (1 or 2). External devices connect to the external ports (1 or 2) and use an LVD (Low Voltage Differential) interface and VHDCI connectors. A #1850 VHDCI to P Converter Cable is available to connect to external devices with type P connectors.

A maximum of one external port per #5736 controller can be used for an EXP24 Disk Enclosure to attach one six-pack of disk. The #0300 specify indicates to the IBM Configurator tool is being used in this manner.

#0647, #5736, #5766 and #5775 are physically the same adapter card but have different feature numbers to indicate to IBM configurator tools that an IOP is or is not being used in the configuration.

#5736 should be the choice over #5702/#5712 or #5705/#5715 controllers for systems running V5R3, or later.

  • Attributes provided: Two Ultra320 SCSI VHDCI ports that may be either internal or external but not both.
  • Attributes required: One available 3.3 volt PCI or PCI-X slot
  • For 9405-520: (#5736)
    • Minimum required: 0
    • Maximum allowed: 57 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#5737) - PCI-X Disk Ctlr-90MB w/IOP

Provides a PCI-X SCSI disk controller that has a 90MB write cache and can provide RAID-5 or RAID-6 protection of disk units.

The #5737 has two U320 SCSI buses each with a bus data rate of up to 320MBs. A maximum of 12 or 24 disk drives and up to two internal removable media devices (tape, CD-ROM, DVD-ROM, or DVD-RAM) are supported on the #5737. The maximum is 12 drives in a #0595/5095 I/O drawer/tower. The maximum is 10 drives in a #5094/5074/5294/5079. The maximum is 24 drives in an EXP24 Disk Enclosure. The #5737 can attach to disk drives within an expansion tower and also attach to disk units in an EXP24 Disk Enclosure. The #0301 specify indicates to the IBM Configurator tool that one port of the #5737 is attaching to disk units in an EXP24 Disk Enclosure.

A minimum of three disk drives are required for RAID-5, providing protection against a single drive failure in an array. A minimum of four disk drives are required for RAID-6, providing protection against up to two drives failing in an array.

#0648, #5737, and #5776 are physically the same adapter card but have different feature numbers to indicate to IBM configurator tools that an IOP is or is not being used in the configuration.

Note: The 757MB write cache and 1.5GB write cache disk controllers provide greater disk performance and can have an auxiliary write cache IOA to protect the write cache contents.

  • Attributes provided: Two Ultra320 SCSI VHDCI ports
  • Attributes required: One available 3.3V long PCI or PCI-X slot
  • For 9405-520: (#5737)
    • Minimum required: 0
    • Maximum allowed: 31 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5738) - PCI-X Disk Ctlr-1.5GB w/IOP

Provides a high-performance PCI-X Ultra320 SCSI disk controller with a maximum compressed write cache of 1.5GB and read cache of 1.6GB. #5738 will support i5/OS mirroring protection for internal disk drives using its write cache but will not start RAID-5 or RAID-6 unless an auxiliary write cache IOA is attached. (When an auxiliary write cache IOA is attached, the pair of cards is denoted by feature code #5582.) Concurrent battery maintenance is supported. The controller also supports internal tape units, CD-ROM units, and DVD units. The #5738 has four internal Ultra320 SCSI buses.

#5738 and #5777 are physically the same adapter card but have different feature numbers to denote to IBM configurator tools whether or not an IOP is required. #5738 indicates an IOP is used.

  • Attributes provided: High-performance SCSI controller.
  • Attributes required: IOP and a PCI-X long card slot
  • For 9405-520: (#5738)
    • Minimum required: 0
    • Maximum allowed: 24 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

    #5738 can not be installed in the model 520 CEC.

(#5739) - PCI-X EXP24 Ctlr-1.5GB w/IOP

(No Longer Available as of November 26, 2010)

Provides an EXP24 disk controller with PCI-X DDR technology, a maximum of 1.5GB compressed write cache, and a maximum 1.6GB compressed read cache. The controller supports RAID-5 and RAID-6 and mirroring is supported via i5/OS. Embedded auxiliary write cache and concurrent battery maintenance are provided. The controller is implemented using two physical cards that are firmly connected and requires two adjacent PCI slots. It provides three Ultra320 SCSI ports/buses for the attachment of disk drives located in a #5786/ #5787 TotalStorage EXP24 Disk Drawer/Tower.

#5739 and #5778 are physically the same adapter cards but have different feature numbers to denote to IBM configuration tools whether or not an IOP is required. #5739 indicates an IOP is used. The #5781/#5782 and #5799/#5800 are also the same adapter cards, but the #5781/#5782 indicates the adapter is placed in a double-wide blind swap cassette and #5799/#5800 indicates the adapter is placed in a system unit and has a light pipe inserted into the feature.

  • Attributes provided: High-performance SCSI RAID Controller
  • Attributes required: Two adjacent PCI-X long card slots and an IOP.
  • For 9405-520: (#5739)
    • Minimum required: 0
    • Maximum allowed: 12 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#5740) - 1Gbps BaseT Ethernet(4-Port)

(No Longer Available as of November 27, 2009)

Provides a 4-port 10/100/1000Mbps BaseT Ethernet adapter, which supports four 1-Gigabit ports on a single adapter, delivering increased bandwidth for slot-constrained servers and providing high connectivity and reliability using two integrated, dual-port Gigabit Ethernet controllers.

Characteristics:

  • Suports 64-bit Bus Mastering on the PCI-X bus
  • Compliant with IEEE 802.3ab 1000Base-T, 803.u 100Base-TX, 802.3 10Base-T standards and supports 802.1q VLAN tagging
  • Supports Interrupt Moderation
  • TCP Segmentation off-load and encapsulation in hardware
  • Checksum Off-loading of IP, TCP, and UDP frame
  • Remote Management Support (WfM,RIS, SNMP/DMI)
  • Delivers increased connectivity while significantly reducing CPU Utilization
  • Provides 10/100/1000Mbps connectivity through four RJ-45 ports using CAT-5 cables
  • Support for Boot ROM on two ports
  • Supports advanced cable diagnostics
  • Utilizes lead free components
  • Adapter dimensions: 4.2" x 6.39"
  • Attributes provided: 4-port 10/100/1000Mbps BaseT Ethernet Adapter
  • Attributes required: One PCI slot
  • For 9405-520: (#5740)
    • Minimum required: 0
    • Maximum allowed: 4 (Initial order maximum: 0)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 4, or later, SUSE Linux Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#5741) - EXP24 6 Disk Slot Enabler

(No Longer Available as of November 26, 2010)

Provides a SCSI interface card (repeater) located in a #5786/ #5787 TotalStorage EXP24 Disk Drawer/Tower. The #5741 receives and sends Ultra320 SCSI signals from an external port of a SCSI disk controller such as a #5736/#5775, #5737/#5776, or #5739/#5778/#5781/ #5782/#5799/#5800 via a SCSI cable. It then sends and receives the signals to the DASD backplane in the #5786/#5787.

A #5741 can enable up to six disk units in a #5786/#5787. One to four #5741's are supported in a #5786/#5787.

  • Attributes provided: SCSI connectivity for up to 6 disk units in a #5786/#5787
  • Attributes required: #5786/#5787 TotalStorage EXP24 Disk Drawer/Tower
  • For 9405-520: (#5741)
    • Minimum required: 0
    • Maximum allowed: 47 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE Linux Enterprise Server 9 for POWER, or later.
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#5742) - EXP24 6/12 Disk Slot Enabler

(No Longer Available as of November 26, 2010)

Provides a SCSI interface card (repeater) located in a #5786/ #5787 TotalStorage EXP24 Disk Drawer/Tower. The #5742 receives and sends Ultra320 SCSI signals from an external port of a SCSI disk controller such as a #5736/#5775, #5737/#5776, or #5739/#5778/#5781/ #5782/#5799/#5800 via a SCSI cable. It then sends and receives the signals to the DASD backplane in the #5786/#5787.

A single #5742 can enable up to six disk units in a #5786/#5787. Two #5742's can be cabled such that up to 12 disk units can be driven by a single SCSI disk controller port with a single SCSI cable. Also a #5742 and a #5741 can be cabled such that up to 12 disk units can be driven by a single SCSI disk controller port with a single SCSI cable

One to four #5742's are supported in a #5786/#5787.

  • Attributes provided: SCSI connectivity for up to 12 disk units in a #5786/#5787
  • Attributes required: #5786/#5787 TotalStorage EXP24 Disk Drawer/Tower
  • For 9405-520: (#5742)
    • Minimum required: 0
    • Maximum allowed: 47 (Initial order maximum: 0)
    • OS level required: i5OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS 3 Update3, or later, SUSE LINUX Enterprise Server 9 for POWER or later.
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#5749) - 4Gbps Fibre Channel (2-Port)

The 4 Gigabit Dual-Port Fibre Channel PCI-X 2.0 DDR Adapter is a 64-bit address/data, short form factor PCI-X adapter with an LC type external fiber connector that provides single or dual initiator capability over an optical fiber link or loop. With the use of appropriate optical fiber cabling, this adapter provides the capability for a network of high-speed local and remote located storage. The adapter will auto-negotiate for the highest data rate between adapter and an attaching device at 1 Gbps, 2 Gbps, or 4 Gbps of which the device or switch is capable. Distances of up to 500 meters running at 1 Gbps data rate, up to 300 meters running at 2 Gbps data rate, and 4 Gbps data rate up to 150 meters are supported between the adapter and an attaching device or switch. When used with IBM Fibre Channel storage switches supporting long-wave optics, distances up to 10 kilometers are capable running at either 1 Gbps, 2 Gbps, or 4 Gbps data rates.

The adapter can be used to attach an IBM DS8000 or DS6800 -- either directly, or by means of Fibre Channel switches. If attaching a DS8000 or DS6800 or a switch with an SC type fiber connector(s), use of an LC-SC 50 Micron Fiber Converter Cable (#2456) or an LC-SC 62.5 Micron Fiber Converter Cable (#2459) is required.

Consult with your IBM representative or Business Partner for additional information relative to any third party attachment.

Note: The #5749 does not support tape or tape libraries on the POWER5/POWER5+ server.

  • Attributes provided: 2 Fibre Channel Ports
  • Attributes required: 1 empty PCI or PCI-X 2.0 slot
  • For 9405-520: (#5749)
    • Minimum required: 0
    • Maximum allowed: 40 (Initial order maximum: 0)
    • OS level required: IBM i 6.1, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#5751) - DVD-RAM

(No longer available as of May 29, 2009)

The #5751 is a DVD slimline device with multiple DVD media read/ write capability. Media support is limited to writing DVD-RAM only, and reading CD-ROM, CD-R, CD-RW, DVD-ROM, and DVD-RAM.

  • Attributes provided: Read/write of DVD-RAM media and read of CD-ROM, CD-R, CD-RW and DVD-ROM media.
  • Attributes required: 5.25-inch, slim removable media bay
  • For 9405-520: (#5751)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5753) - 30GB 1/4-Inch Cartridge Tape

(No Longer Available as of November 27, 2009)

Mounted in a removable media device slot in a system unit, the #5753 may be used for save/restore, alternate IPL, program distribution, migration and 1/4-inch cartridge tape exchange.

#5753 will read/write the following tape formats:

  • 30GB (up to 60GB with compression in SLR60 format) with IBM SLR60-30GB Data Cartridge (19P4209)
  • 25GB (up to 50GB with compression in MLR3 format) with IBM MLR3-25GB Data Cartridge (59H4128)
  • 16GB (up to 32GB with compression in QIC5010 format) with IBM MLR1-16GB Data Cartridge (59H4175)
  • 5GB (up to 10GB with compression in SLR100 format) with IBM SLR100-5GB Data Cartridge (35L0661)
  • 2GB (up to 4GB with compression in QIC5010 format) with IBM MLR1-2GB Data Cartridge (35L0589)

#5753 is capable of read only support of the following tape formats:

  • 4GB (QIC4GB format) with SLR5-4GB Data Cartridge (59H3660)
  • 2.5GB (QIC2GB format) with IBM DC9250 Data Cartridge (16G8436)

#5753 has the these technical specifications for the primary recording format:

  • Cartridge Capacity (Native) = 30.0GB (1500-ft tape)
  • Cartridge Capacity (Compression) = 60.0GB (1500-ft tape)
  • Data Rate (Native) = 4.0MB/s
  • Data Rate (Compression) = 8.0MB/s
  • Attributes provided: 30GB 1/4-inch tape device
  • Attributes required: Half-high, bolt-in, removable media bay in a system unit.
  • For 9405-520: (#5753)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

    #5753 may be mounted in a removable media device slot in the model 520 system unit.

(#5754) - 50GB 1/4-Inch Cartridge Tape

(No Longer Available as of November 27, 2009)

Mounted in a removable media device slot in a system unit, #5754 can be used for save/restore, alternate IPL, program distribution, migration, and 1/4-inch cartridge tape exchange.

Will READ/WRITE:

  • 50GB (up to 100GB with compression in SLR100 format) with IBM SLR100-50GB Data Cartridge (35L0968)
  • 30GB (up to 60GB with compression in SLR60 format) with IBM SLR60-30GB Data Cartridge (19P4209)
  • 25GB (up to 50GB with compression in MLR3 format) with IBM MLR3-25GB Data Cartridge (59H4128)
  • 5GB (up to 10GB with compression in SLR100 format) with IBM SLR100-5GB Data Cartridge (35L0661)

Will READ:

  • 16GB (up to 32GB with compression in QIC5010 format) with IBM MLR1-16GB Data Cartridge (59H4175)
  • 4GB (QIC4GB format) with SLR5-4GB data Cartridge (59H3660)
  • 2GB (up to 4GB with compression in QIC5010 format) with IBM MLR1-2GB

Specifications for the primary recording format:

  • Cartridge Capacity (Native) = 50.0GB (1500-ft tape)
  • Cartridge Capacity (Compression) = 100.0GB (1500-ft tape)
  • Data Rate (Native) = 5.0MB/s
  • Data Rate (Compression) = 10.0MB/s
  • Attributes provided: 50GB 1/4-inch tape device
  • Attributes required: Half-high, bolt-in, removable media bay in a system unit.
  • For 9405-520: (#5754)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

    #5754 may be mounted in a removable media device slot in the model 520.

(#5755) - 200GB LTO-2 Tape Unit

(No Longer Available as of November 27, 2009)

Provides a 200 GB native capacity (400 GB compressed capacity) tape device that installs in a half-high removable media device slot in the system unit. The #5755 can read and write both LTO Gen-1 and LTO Gen-2 tape cartridges.

Specifications:

  • Cartridge capacity (native): 200 GB
  • Cartridge capacity (compressed): 400 GB
  • Data rate (native): 24 MBps
  • Data rate (compressed): 48 MBps
  • Interface: SCSI-3 low voltage differential (LVD)/single ended (SE)
  • Media: LTO Gen-1 or LTO Gen-2 Data Cartridge
  • Form factor: 5.25-inch, half-high
  • Mounting type: Bolt-in
  • Attributes provided: 200GB LTO tape device
  • Attributes required: One 5.25-Inch, half-high removable media device slot
  • For 9405-520: (#5755)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE Linux Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

    #5755 may be mounted in the removable media device slot in the model 520 system unit.

(#5758) - 4Gbps Fibre Channel (1-Port)

(No longer available as of October 01, 2006)

Provides a 4Gbps Single Port Fibre Channel PCI-X 2.0 Adapter, which is a 64-bit address/data, short form factor PCI-X adapter with an LC type external fiber connector that provides single initiator capability over an optical fiber link or loop. With the use of appropriate optical fiber cabling, this adapter provides the capability for a network of high-speed local and remote located storage.

The #5758 will auto-negotiate for the highest data rate between adapter and an attaching device at 1Gbps, 2Gbps or 4Gbps of which the device or switch is capable. Distances of up to 500 meters running at 1Gbps data rate and up to 300 meters running at 2Gbps data rate and 4Gbps data rate up to 150 meters are supported between the adapter and an attaching device or switch. When used with IBM supported Fibre Channel storage switches supporting long-wave optics, distances of up to 10 kilometers are capable of running at either 1, 2, or 4Gbps data rates.

The #5758 can be used to attach devices either directly, or by means of Fibre Channel Switches. If attaching a device or switch with an SC type fiber connector, use of an LC-SC 50 Micron Fiber Converter Cable (#0371) or an LC-SC 62.5 Micron Fiber Converter Cable (#0372) is required.

Features #5758 and #5761 are physically the same card, but have different feature numbers that denote to IBM configurator tools whether or not an IOP is required. #5758 does not require a PCI IOP.

For information on additional supported system attachment for IBM devices, visit:

http://www.ibm.com/servers/storage/product/products_pseries.html

Contact your IBM representative or Business Partner for additional information about any third-party attachment.

  • Attributes provided: One Port Fibre Channel Adapter
  • Attributes required: One empty PCI-X 1.0 / 2.0 slot
  • For 9405-520: (#5758)
    • Minimum required: 0
    • Maximum allowed: 36 (Initial order maximum: 0)
    • OS level required: AIX 5L for Power V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 4, or later, SUSE Linux Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5759) - 4Gbps Fibre Channel (2-Port)

(No Longer Available as of July 11, 2014)

Provides a 4Gbps Dual-Port Fibre Channel PCI-X 2.0 Adapter, which is a 64-bit address/data, short form factor PCI-X adapter with an LC type external fiber connector that provides single or dual initiator capability over an optical fiber link or loop. With the use of appropriate optical fiber cabling, this adapter provides the capability for a network of high-speed local and remote located storage.

The #5759 will auto-negotiate for the highest data rate between adapter and an attaching device at 1Gbps, 2Gbps, or 4Gbps of which the device or switch is capable. Distances of up to 500 meters running at 1Gbps data rate, up to 300 meters running at 2Gbps data rate, and 4Gbps data rate up to 150 meters are supported between the adapter and an attaching device or switch. When used with IBM Fibre Channel storage switches supporting long-wave optics, distances up to 10 kilometers are capable running at either 1Gbps, 2 Gbps, or 4Gbps data rates.

The #5759 can be used to attach devices either directly, or by means of Fibre Channel Switches. If attaching a device or switch with an SC type fiber connector(s), use of an LC-SC 50 Micron Fiber Converter Cable (#0371) or an LC-SC 62.5 Micron Fiber Converter Cable (#0372) is required.

For additional information on supported server attachment information for IBM devices, visit:

http://www.ibm.com/servers/storage/product/products_pseries.html

Contact your IBM representative or Business Partner for additional information about any third-party attachment.

  • Attributes provided: Two Port Fibre Channel Adapter
  • Attributes required: One empty PCI-X 1.0 / 2.0 slot
  • For 9405-520: (#5759)
    • Minimum required: 0
    • Maximum allowed: 18 (Initial order maximum: 0)
    • OS level required: AIX 5.2L for Power V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 4, or later, SUSE Linux Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#5760) - PCI-X Fibre Chan Disk Ctlr

(No Longer Available as of November 26, 2010)

Provides a 4Gbps Single Port Fibre Channel PCI-X 2.0 Adapter, which attaches external DASD devices. #5760 is a 64-bit address/ data, short form factor PCI-X adapter with an LC type external fiber connector that provides single initiator capability over an optical fiber link or loop. With the use of appropriate optical fiber cabling, this adapter provides the capability for a network of high-speed local and remote located storage.

The #5760 will auto-negotiate for the highest data rate between adapter and an attaching device at 1Gbps, 2Gbps or 4Gbps of which the device or switch is capable. Distances of up to 500 meters running at 1Gbps data rate and up to 300 meters running at 2Gbps data rate and 4Gbps data rate up to 150 meters are supported between the adapter and an attaching device or switch. When used with IBM supported Fibre Channel storage switches supporting long-wave optics, distances of up to 10 kilometers are capable running at either 1Gbps or 2Gbps or 4Gbps data rates.

The #5760 can be used to attach devices either directly, or by means of Fibre Channel Switches. If attaching a device or switch with a SC type fiber connector, use of a #0371 LC-SC Adapter Kit (50um) or a #0372 LC-SC Adapter Kit (62.5um) is required.

The #5760 requires a PCI IOP.

Refer to the following IBM storage subsystem Web page for additional supported server attachment information for IBM devices:

http://www.ibm.com/servers/storage/product/products_iseries.html

Consult with your IBM representative or Business Partner for additional information relative to any third party attachment.

  • Attributes provided: One Port Fibre Channel Adapter that attaches External DASD
  • Attributes required: One empty PCI-X 1.0 / 2.0 slot and a PCI IOP
  • For 9405-520: (#5760)
    • Minimum required: 0
    • Maximum allowed: 37 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#5761) - PCI-X Fibre Chan Tape Ctlr

(No Longer Available as of November 26, 2010)

Provides a 4Gbps Single Port Fibre Channel PCI-X 2.0 Adapter, which attaches external tape devices. #5761 is a 64-bit address/ data, short form factor PCI-X adapter with an LC type external fiber connector that provides single initiator capability over an optical fiber link or loop. With the use of appropriate optical fiber cabling, this adapter provides the capability for a network of high-speed local and remote located storage.

The #5761 will auto-negotiate for the highest data rate between adapter and an attaching device at 1Gbps, 2Gbps or 4Gbps of which the device or switch is capable. Distances of up to 500 meters running at 1Gbps data rate and up to 300 meters running at 2Gbps data rate and 4Gbps data rate up to 150 meters are supported between the adapter and an attaching device or switch. When used with IBM supported Fibre Channel storage switches supporting long-wave optics, distances of up to 10 kilometers are capable running at either 1Gbps or 2Gbps or 4Gbps data rates.

The #5761 can be used to attach devices either directly, or by means of Fibre Channel Switches. If attaching a device or switch with a SC type fiber connector, use of a #0371 LC-SC Adapter Kit (50um) or a #0372 LC-SC Adapter Kit (62.5um) is required.

Features #5761 and #5758 are physically the same card, but have different feature numbers that denote to IBM configurator tools whether or not an IOP is required.

Refer to the following IBM storage subsystem Web page for additional supported server attachment information for IBM devices:

http://www.ibm.com/servers/storage/product/products_iseries.html

Consult with your IBM representative or Business Partner for additional information relative to any third party attachment.

  • Attributes provided: One Port Fibre Channel Adapter that attaches External Tape Devices
  • Attributes required: One empty PCI-X 1.0 / 2.0 slot and a PCI IOP
  • For 9405-520: (#5761)
    • Minimum required: 0
    • Maximum allowed: 36 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#5775) - PCI-X Disk/Tape Ctlr-No IOP

Provides a PCI-X Disk/Tape SCSI Controller with zero write cache and without RAID support. Disk mirroring is supported through i5/OS. A maximum of six disk drives are supported on the #5775. Removable media devices (tape, optical libraries, DVD-ROM, or DVD-RAM) are also supported on the #5775.

The #5775 has two U320 buses each with a bus data rate of up to 320MBs. Each SCSI bus can be either internal (using an internal port) or external (using an external port), but not both. There are four physical ports on the #5775, two internal and two external.

Internal devices connect to the internal ports (1 or 2). External devices connect to the external ports (1 or 2) and use an LVD (Low Voltage Differential) interface and VHDCI connectors. A #1850 VHDCI to P Converter Cable is available to connect to external devices with type P connectors.

A maximum of one external port per #5775 controller can be used for an EXP24 Disk Enclosure to attach one six-pack of disk. The #0300 specify indicates to the IBM Configurator tool it is being used in this manner.

#0647, #5736, #5766 and #5775 are physically the same adapter card but have different feature numbers to indicate to IBM configurator tools that an IOP is or is not being used in the configuration.

#0647 should be the choice over #0624/#0645 (#5702/#5712 Direct Attach equivalent) and #5736 should be the choice over #5705/#5715 controllers for systems running V5R3, or later. #5775 should be the choice for systems where IOPless support is provided.

The 30GB QIC, 50GB QIC, 80GB VXA, 160GB VXA and 200GB HH LTO-2 tape drives are supported with this feature (no IOP). Also supported are a DVD-ROM, DVD-RAM, CD-ROM and optical disk drives.

  • Attributes provided: Two Ultra320 SCSI VHDCI ports that may be either internal or external but not both.
  • Attributes required: One available 3.3 volt PCI or PCI-X slot
  • For 9405-520: (#5775)
    • Minimum required: 0
    • Maximum allowed: 73/89 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3 w/ V5R3M5 Machine Code, or later, for 1.9GHz processors; i5/OS V5R4, or later, for 1.5/1.65GHz processors
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#5776) - PCI-X Disk Ctlr-90MB No IOP

Provides a PCI-X SCSI disk controller that has a 90MB write cache and can provide RAID-5 or RAID-6 protection of disk units.

The #5776 has two U320 SCSI buses each with a bus data rate of up to 320MBs. A maximum of 12 or 24 disk drives and up to two internal removable media devices (tape, DVD-ROM, or DVD-RAM) are supported on the #5776. The maximum is 12 drives in a #0595/5095 I/O drawer/ tower. The maximum is 10 drives in a #5094/5074/5294/5079. The maximum is 24 drives in an EXP24 Disk Enclosure. The #5776 can attach to disk drives within an expansion tower and also attach to disk units in an EXP24 Disk Enclosure. The #0301 specify indicates to the IBM Configurator tool that one port of the #5776 is attaching to disk units in an EXP24 Disk Enclosure.

A minimum of three disk drives are required for RAID-5, providing protection against a single drive failure in an array. A minimum of four disk drives are required for RAID-6, providing protection against up to two drives failing in an array.

#0648, #5737, and #5776 are physically the same adapter card but have different feature numbers to indicate to IBM configurator tools that an IOP is or is not being used in the configuration.

Note: The 757MB write cache and 1.5GB write cache disk controllers provide greater disk performance and have an auxiliary write cache IOA to protect the write cache contents.

  • Attributes provided: Two Ultra320 SCSI VHDCI ports
  • Attributes required: One available 3.3V long PCI or PCI-X slot
  • For 9405-520: (#5776)
    • Minimum required: 0
    • Maximum allowed: 31 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3 w/ V5R3M5 Machine Code, or later, for 1.9GHz processors; i5/OS V5R4, or later, for 1.5/1.65GHz processors
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5777) - PCI-X Disk Ctlr-1.5GB No IOP

Provides a high-performance PCI-X Ultra320 SCSI disk controller with a maximum compressed write cache of 1.5GB and read cache of 1.6GB. #5777 will support i5/OS mirroring protection for internal disk drives using the write cache, but will not use the write cache to run RAID-5 or RAID-6 unless an auxiliary write cache IOA is attached. Running RAID-5 or RAID-6 without write cache very significantly reduces its performance. (When an auxiliary write cache IOA is attached, the pair of cards is denoted by feature code #5582.) Concurrent battery maintenance is supported. The controller also supports internal tape units, CD-ROM units, and DVD units. The #5738 has four internal Ultra320 SCSI buses.

#5777 and #5738 are physically the same adapter card but have different feature numbers to denote to IBM configurator tools whether or not an IOP is required. #5777 does not require an IOP.

  • Attributes provided: High performance disk controller
  • Attributes required: A single long PCI-X slot
  • For 9405-520: (#5777)
    • Minimum required: 0
    • Maximum allowed: 24 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

    #5777 can not be installed in the model 520 CEC.

(#5778) - PCI-X EXP24 Ctl-1.5GB No IOP

(No Longer Available as of November 26, 2010)

Provides an EXP24 disk controller with PCI-X DDR technology, a maximum of 1.5GB compressed write cache and a maximum 1.6GB compressed read cache. The controller supports RAID-5 and RAID-6 and mirroring is supported via i5/OS. Embedded auxiliary write cache and concurrent battery maintenance are provided. The controller is implemented using two physical cards that are firmly connected and requires two adjacent PCI slots. It provides three Ultra320 SCSI ports/buses for the attachment of disk drives located in a #5786/ #5787 TotalStorage EXP24 Disk Drawer/Tower.

#5778 and #5739 are physically the same adapter cards but have different feature numbers to denote to IBM configuration tools whether or not an IOP is required. #5778 indicates an IOP is not used. #5781/#5782 and #5799/#5800 are also the same adapter cards, but the #5781/#5782 indicates the adapter is placed in a double-wide blind swap cassette and #5799/#5800 indicates the adapter is placed in a system unit and has a light pipe inserted into the feature.

  • Attributes provided: High performance RAID disk controller
  • Attributes required: Two adjacent long PCI-X slots
  • For 9405-520: (#5778)
    • Minimum required: 0
    • Maximum allowed: 16 (Initial order maximum: 0)
    • OS level required: i5/OS V5R4, or later.
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#5781) - PCI-X EXP24 Ctlr-1.5GB w/IOP

(No Longer Available as of November 26, 2010)

Provides an EXP24 disk controller with PCI-X DDR technology, a maximum of 1.5GB compressed write cache and a maximum 1.6GB compressed read cache. The controller supports RAID-5 and RAID-6 and mirroring is supported via i5/OS. Embedded auxiliary write cache and concurrent battery maintenance are provided. The controller is implemented using two physical cards that are firmly connected and requires two adjacent PCI slots. It provides three Ultra320 SCSI ports/buses for the attachment of disk drives located in a #5786/ #5787 TotalStorage EXP24 Disk Drawer/Tower.

This feature includes a double-wide blind swap cassette in which the disk controller is placed. The cassette is required to locate the disk controller in a 570 system unit or #5790 I/O drawer.

#5781 and #5782 are physically the same adapter card but have different feature numbers to denote to IBM configuration tools whether or not an IOP is required. #5781 indicates an IOP is used. #5739/#5778 and #5799/#5800 are also the same adapter cards, but the #5781/#5782 indicates the adapter is placed in a double-wide blind swap cassette and #5799/#5800 indicates the adapter is placed in a system unit and has a light pipe inserted into the feature.

  • Attributes provided: High-performance SCSI RAID controller in a double wide blind swap cassette.
  • Attributes required: Two adjacent PCI-X long card slots, in a blind swap capable system unit or expansion unit, and an IOP.
  • For 9405-520: (#5781)
    • Minimum required: 0
    • Maximum allowed: 12 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#5782) - PCI-X EXP24 Ctl-1.5GB No IOP

(No Longer Available as of November 26, 2010)

Provides an EXP24 disk controller with PCI-X DDR technology, a maximum of 1.5GB compressed write cache and a maximum 1.6GB compressed read cache. The controller supports RAID-5 and RAID-6 and mirroring is supported via i5/OS. Embedded auxiliary write cache and concurrent battery maintenance are provided. The controller is implemented using two physical cards that are firmly connected and requires two adjacent PCI slots. It provides three Ultra320 SCSI ports/buses for the attachment of disk drives located in a #5786/ #5787 TotalStorage EXP24 Disk Drawer/Tower.

This feature includes a double-wide blind swap cassette in which the disk controller is placed. The cassette is required to locate the disk controller in a 570 system unit or #5790 I/O drawer.

#5782 and #5781 are physically the same adapter card but have different feature numbers to denote to IBM configuration tools whether or not an IOP is required. #5782 indicates an IOP is not used. #5739/#5778 and #5799/#5800 are also the same adapter cards, but the #5781/#5782 indicates the adapter is placed in a double-wide blind swap cassette and #5799/#5800 indicates the adapter is placed in a system unit and has a light pipe inserted into the feature.

  • Attributes provided: High-performance SCSI RAID controller in a double wide blind swap cassette.
  • Attributes required: Two adjacent PCI-X long card slots, in a blind swap capable system unit or expansion unit.
  • For 9405-520: (#5782)
    • Minimum required: 0
    • Maximum allowed: 12 (Initial order maximum: 0)
    • OS level required: i5/OS V5R4, or later.
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#5783) - PCI-X iSCSI HBA Copper

This feature provides a 1Gbps copper iSCSI target HBA, which is used to connect to iSCSI initiator HBAs installed in selected System x models or IBM BladeCenter blade servers. The iSCSI connection is used to provide System i systems management, networking, and disk consolidation features to attached System x or blade servers using a 1Gbps Ethernet LAN.

#5783 uses an RJ45 Gigabit Ethernet connector and provides 1000Mbps connectivity over standard CAT-5e or CAT6 cables to support communications up to a distance of 100m. #5783 conforms to the iEEE 802.3ab 1000Base-T standard.

  • Attributes provided: Connection to target host bus adapter (HBA)
  • Attributes required: Available 3.3V slot
  • For 9405-520: (#5783)
    • Minimum required: 0
    • Maximum allowed: 21 (Initial order maximum: 0)
    • OS level required: i5/OS V5R4, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#5784) - PCI-X iSCSI HBA Fiber

(No Longer Available as of January 7, 2011)

This feature provides a 1Gbps fiber iSCSI target HBA, which is used to connect to iSCSI initiator HBAs installed in selected System x models or IBM BladeCenter blade servers. The iSCSI connection provides System i systems management, networking, and disk consolidation features to attached System x or blade servers using a 1Gbps Ethernet LAN.

#5784 uses small form factor LC type fiber optic connector and provides 1000Mbps connectivity on a standard shortwave (850nm) 50/ 62.5 micron multimode fiber optic cable. #5784 supports distances of up to 220m for 62.5u MMF and up to 500m for 50.0u MMF over single port. #5784 conforms to the IEEE 802.3z standard.

  • Attributes provided: Connection to target host bus adapter (HBA)
  • Attributes required: Available 3.3V PCI-X slot
  • For 9405-520: (#5784)
    • Minimum required: 0
    • Maximum allowed: 21 (Initial order maximum: 0)
    • OS level required: i5/OS V5R4, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#5786) - TotalStorage EXP24 Disk Dwr

(No Longer Available as of November 26, 2010)

Provides disk slots for up to 24 disk units in a 19-inch, 4 EIA high rack drawer. The #5786 provides redundant power, redundant cooling, and Ultra 320 SCSI interface connections for 24 Ultra 320 SCSI disk units that are organized in four independent groups of six disk units.

#5741 and/or #5742 EXP24 Disk Slot Enablers (SCSI repeaters) enable these groups of six disk unit slots. The enabled disk slots are driven by SCSI disk controllers located outside the #5786 and connected by a SCSI cable. One to four Disk Slot Enablers are required, depending on the number of disk unit groups populated with disk units.

One external port on a disk controller such as a #5736/#5737/ #5739/#5775/#5776/#5778/#5781/#5782/#5799/#5800 is required for each #5741 installed. Likewise, one external disk controller port is required for each #5742 installed and cabled to run one group of six disk slots. Alternately, two #5742s can be cabled such that a single disk controller can run two groups of six disk slots. Or, one #5741 plus one #5742 can also be cabled such that a single disk controller can run two groups of six disk slots.

The following SCSI cables are available:

  • #2138 0.55m SCSI Cable
  • #2124 1m SCSI Cable
  • #2125 3m SCSI Cable
  • #2126 5m SCSI Cable
  • #2127 10m SCSI Cable
  • #2128 20m SCSI Cable

Note: Do not use the 0.55m cable (#2138) to cable two disk slot enablers together. If this is done, there is not enough slack in the cable to allow additional disk units to be installed in that #5786.

Specific disk unit feature numbers are used to identify disk units that will be placed in the #5786. These disk units are physically the same disk units as used in other System i system units and I/O tower/drawers. Using separate feature codes allows IBM configuration tools to better understand their placement. Feature code numbers of #5786 disk units include: #1266, #1267, #1268, #1269, #1292, #1293, #1294, #1295, #1296, #1297, #1298 and #1299.

  • Attributes provided: 24 Ultra 320 SCSI disk unit slots
  • Attributes required: Disk controller with external Ultra 320 SCSI port and 4 EIA units of space in a 19-inch rack
  • For 9405-520: (#5786)
    • Minimum required: 0
    • Maximum allowed: 12 (Initial order maximum: 0)
    • OS level required: i5OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS 3 Update3, or later, SUSE LINUX Enterprise Server 9 for POWER or later.
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#5787) - TotalStorage EXP24 Disk Twr

(No longer available as of October 01, 2008)

Provides disk slots for up to 24 disk units in a stand-alone disk tower. The #5787 provides redundant power, redundant cooling, and Ultra 320 SCSI interface connections for 24 Ultra 320 SCSI disk units, which are organized in four independent groups of six disk units.

#5741 and/or #5742 EXP24 Disk Slot Enablers (SCSI repeaters) enable these groups of six disk unit slots. The enabled disk slots are driven by SCSI disk controllers located outside the #5787 and connected by a SCSI cable. One to four Disk Slot Enablers are required, depending on the number of disk unit groups populated with disk units.

One external port on a disk controller such as a #5736/#5737/ #5739/#5775/#5776/#5778/#5781/#5782/#5799/#5800 is required for each #5741 installed. Likewise, one external disk controller port is required for each #5742 installed and cabled to run one group of six disk slots. Alternately, two #5742's can be cabled such that a single disk controller can run two groups of six disk slots. Or, one #5741 plus one #5742 can also be cabled such that a single disk controller can run two groups of six disk slots.

The following SCSI cables are available:

  • #2138 0.55m SCSI Cable
  • #2124 1m SCSI Cable
  • #2125 3m SCSI Cable
  • #2126 5m SCSI Cable
  • #2127 10m SCSI Cable
  • #2128 20m SCSI Cable

Specific disk unit feature numbers are used to identify disk units that will be placed in the #5787. These disk units are physically the same disk units as used in other System i system units and I/O tower/drawers. Using separate feature numbers allows IBM configuration tools to better understand their placement. Feature numbers of #5787 disk units include: #1266, #1267, #1268, #1269, #1292, #1293, #1294, #1295, #1296, #1297, #1298 and #1299.

  • Attributes provided: 24 Ultra 320 SCSI disk slots
  • Attributes required: Disk controller with external Ultra 320 SCSI port
  • For 9405-520: (#5787)
    • Minimum required: 0
    • Maximum allowed: 12 (Initial order maximum: 0)
    • OS level required: i5OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS 3 Update3, or later, SUSE LINUX Enterprise Server 9 for POWER or later.
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5790) - PCI Expansion Drawer

(No Longer Available as of November 26, 2010)

The #5790 is a four EIA unit I/O expansion drawer that can accommodate six blind swap I/O adapters and is attached to the system using a RIO/HSL bus. The #5790 includes redundant concurrently maintainable power and cooling and the blind swap PCI mechanism allows for PCI card servicing without removing the I/O expansion drawer.

The #5790 mounts in a 19-inch rack using a #7307 Dual I/O Unit Enclosure or a #7311 Dual I/O Unit Enclosure. Two #5790 drawers can be mounted side-by-side in a single #7307 or #7311 and are not required to be attached to the same system. A bus adapter to provide the HSL interface to the system is required.

  • Attributes provided: 6 PCI-X slots for blind swap I/O adapters
  • Attributes required: Rack space in a #7307 Dual I/O Unit Enclosure or a #7311 Dual I/O Unit Enclosure, a RIO-G/HSL-2 cable, an SPCN cable, and an HSL bus adapter: #6438 (if ordered on a 9408-M25 or a 9409-M50) or #9531.
  • For 9405-520: (#5790)
    • Minimum required: 0
    • Maximum allowed: 6 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#5799) - PCI-X EXP24 Ctlr-1.5GB w/IOP

(No longer available as of December 02, 2008)

Provides an EXP24 disk controller with PCI-X DDR technology, a maximum of 1.5GB compressed write cache and a maximum 1.6GB compressed read cache. The controller supports RAID-5 and RAID-6 and mirroring is supported via i5/OS. Embedded auxiliary write cache and concurrent battery maintenance are provided. The controller is implemented using two physical cards that are firmly connected and requires two adjacent PCI slots. It provides three Ultra320 SCSI ports/buses for the attachment of disk drives located in a #5786/ #5787 TotalStorage EXP24 Disk Drawer/Tower.

This feature includes an attached "light pipe" for viewing system status LEDs and can only be placed in a system unit enclosure.

#5799 and #5800 are physically the same adapter card but have different feature numbers to denote to IBM configuration tools whether or not an IOP is required. #5799 indicates an IOP is used. #5739/#5778 and #5781/#5782 are also the same adapter cards, but the #5781/#5782 indicates the adapter is placed in a double-wide blind swap cassette and #5799/#5800 indicates the adapter has a light pipe inserted into the feature.

  • Attributes provided: High-performance SCSI RAID Controller
  • Attributes required: Two adjacent PCI-X long card slots and an IOP.
  • For 9405-520: (#5799)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5800) - PCI-X EXP24 Ctl-1.5GB No IOP

(No longer available as of December 02, 2008)

Provides an EXP24 disk controller with PCI-X DDR technology, a maximum of 1.5GB compressed write cache and a maximum 1.6GB compressed read cache. The controller supports RAID-5 and RAID-6 and mirroring is supported via i5/OS. Embedded auxiliary write cache and concurrent battery maintenance are provided. The controller is implemented using two physical cards that are firmly connected and requires two adjacent PCI slots. It provides three Ultra320 SCSI ports/buses for the attachment of disk drives located in a #5786/ #5787 TotalStorage EXP24 Disk Drawer/Tower.

This feature includes an attached "light pipe" for viewing system status LEDs and can only be placed in a system unit enclosure.

#5800 and #5799 are physically the same adapter card but have different feature numbers to denote to IBM configuration tools whether or not an IOP is required. #5800 indicates an IOP not is used. #5739/#5778 and #5781/#5782 are also the same adapter cards, but the #5781/#5782 indicates the adapter is placed in a double-wide blind swap cassette and #5799/#5800 indicates the adapter has a light pipe inserted into the feature.

  • Attributes provided: High performance RAID disk controller
  • Attributes required: Two adjacent long PCI-X slots
  • For 9405-520: (#5800)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: i5/OS V5R4, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5886) - EXP 12S SAS Disk Drawer

(No Longer Available as of January 6, 2012)

EXP 12S is an expansion drawer with 12 SAS storage slots. #5886 supports up to 12 hot-swap SAS disk drives in mega-pack carriers. The SAS enclosure includes redundant AC power supplies and two service managers. EXP 12S takes up a two EIA space in a 19-inch rack. The enclosure attaches to a host server using the appropriate external SAS cables and SAS controllers.

  • Attributes provided: 12 disk bays and up to 11 slot filler panels
  • Attributes required: Available SAS Port, Available 2U Rack Space. At least one SAS drive must be ordered for each #5886 enclosure
  • For 9405-520: (#5886)
    • Minimum required: 0
    • Maximum allowed: 24 (Initial order maximum: 0)
    • OS level required: IBM i 5.4 with V5R4M5 SLIC, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#5904) - PCI-X DDR 1.5GB SAS RAID Adptr

(No Longer Available as of July 11, 2014)

PCI-X DDR 1.5GB Cache SAS RAID Adapter provides an EXP 12S SAS disk controller with PCI-X DDR technology, a maximum of 1.5GB compressed write cache and a maximum 1.6GB compressed read cache. Auxiliary write cache and concurrent battery maintenance are provided. The controller is implemented using two physical cards that are firmly connected and requires two adjacent PCI slots. It provides three mini-SAS 4x connectors for the attachment of SAS drives located in a #5886 EXP 12S Expansion Drawer. The controller supports a maximum of three SAS #5886 EXP 12S Expansion Drawers. With proper cabling and configuration, multiple wide ports are used to provide redundant paths to each dual port SAS disk or SSD. The adapter manages SAS path redundancy and path switching should a SAS drive failure occur. CCIN is 572F/575C.

The adapter provides RAID 0, RAID 5, RAID 6. Under IBM i OS, mirroring and data spreading is provided by the operating system and RAID 5 and RAID 6 is provided by the adapter.

#5904 and #5908 are feature codes representing the same physical cards, but use different feature codes to indicate if a blind swap cassette is used and its type. #5904 indicates no blind swap cassette and is used in enclosures such as a #5094 or #0595 I/O drawer.

When used in POWER5 based system configuration the following restrictions apply:

  • The maximum number of #5886 EXP 12S Expansion drawers that may be attached per controller is three (one per adapter port).
  • IBM i load source capability is not provided

Highlights

  • SAS speed = 3Gb/s
  • SAS-SSP, SMP are supported
  • Supports single controller with SAS y cables( #3692, 3693, 3694)
  • Built-in auxiliary cache mirrors write cache for redundancy
  • For 9405-520: (#5904)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 0)

      Note: Combine total for 5904 and 5908 is maximum of 8.

    • OS level required: IBM i 5.4 with V5R4M5 SLIC, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#5908) - PCI-X DDR 1.5GB SAS RAID Adptr

(No Longer Available as of July 11, 2014)

PCI-X DDR 1.5GB cache SAS RAID Adapter provides an EXP 12S SAS disk controller with PCI-X DDR technology, a maximum of 1.5GB compressed write cache and a maximum 1.6GB compressed read cache. Auxiliary write cache and concurrent battery maintenance are provided. The controller is implemented using two physical cards that are firmly connected and requires two adjacent PCI slots. It provides three mini-SAS 4x connectors for the attachment of SAS drives located in a #5886 EXP 12S Expansion Drawers. The controller supports a maximum of three SAS #5886 EXP 12S Expansion Drawers. With proper cabling and configuration, multiple wide ports are used to provide redundant paths to each dual port SAS disk or SSD. The adapter manages SAS path redundancy and path switching should a SAS drive failure occur.

The adapter provides RAID 0, RAID 5, RAID 6. Under IBM i OS, mirroring and data spreading is provided by the operating system and RAID 5 and RAID 6 is provided by the adapter.

#5904 and #5908 are feature codes representing the same physical cards, but use different feature codes to indicate if a blind swap cassette is used and its type. #5908 indicates a Gen-3 blind swap cassette used in the #5790 enclosure.

When used in POWER5 based system configuration the following restrictions apply:

  • The maximum number of #5886 EXP 12S Expansion drawers that may be attached per controller is three.
  • IBM i load source capability is not provided

Highlights

  • SAS speed = 3Gb/s
  • SAS-SSP, SMP are supported
  • Supports single controller with SAS y cables( #3692, 3693, 3694)
  • Built-in auxiliary cache mirrors write cache for redundancy
  • For 9405-520: (#5908)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 0)

      Note: Combine total for 5904 and 5908 is maximum of 8.

    • OS level required: IBM i 5.4 with V5R4M5 SLIC, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#5951) - USB Keyboard-US English

(No Longer Available as of August 31, 2012)

This feature provides a USB attached US English #103P keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#5951)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5952) - USB Keyboard-French

(No Longer Available as of August 31, 2012)

This feature provides a USB attached French #189 keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#5952)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5953) - USB Keyboard-Italian

(No Longer Available as of August 31, 2012)

This feature provides a USB attached Italian #142 keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#5953)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5954) - USB Keyboard-German/Austrian

(No Longer Available as of August 31, 2012)

This feature provides a USB attached German/Austrian #129 keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#5954)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5955) - USB Keyboard-UK English

(No Longer Available as of August 31, 2012)

This feature provides a USB attached UK English #166 keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#5955)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5956) - USB Keyboard-Spanish

(No Longer Available as of August 31, 2012)

This feature provides a USB attached Spanish #172 keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#5956)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5957) - USB Keybd-Japanese

(No Longer Available as of August 31, 2012)

This feature provides a USB attached Japanese #194P keyboard. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#5957)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5958) - USB Keybd-Brazil/Portuguese

(No Longer Available as of August 31, 2012)

This feature provides a USB attached Brazilian Portuguese #275 keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#5958)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5959) - USB Keybd-Hungarian

(No Longer Available as of August 31, 2012)

This feature provides a USB attached Hungarian #208 keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#5959)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5960) - USB Keybd-Korean

(No Longer Available as of August 31, 2012)

This feature provides a USB attached Korean #413 keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#5960)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5961) - USB Keybd-Chinese/US

(No Longer Available as of August 31, 2012)

This feature provides a USB attached Chinese #467 keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#5961)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5962) - USB Keybd-French/Canadian

(No Longer Available as of August 31, 2012)

This feature provides a USB attached French Canadian #445 keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#5962)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5963) - USB Keyboard-Canadian/French

(No longer available as of July 08, 2008)

This feature provides a USB attached Canadian French #058 keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#5963)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#5964) - USB Keyboard-Belgium/UK

(No Longer Available as of August 31, 2012)

This feature provides a USB attached Belgian/UK #120 keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#5964)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5965) - USB Keyboard-Swedish/Finnish

(No Longer Available as of August 31, 2012)

This feature provides a USB attached Swedish/Finnish #153 keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#5965)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5966) - USB Keyboard-Danish

(No Longer Available as of August 31, 2012)

This feature provides a USB attached Danish #159 keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#5966)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5967) - USB Keybd-Bulgarian

(No Longer Available as of August 31, 2012)

This feature provides a USB attached Bulgarian #442 keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#5967)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5968) - USB Keyboard-Swiss/Fr/German

(No Longer Available as of August 31, 2012)

This feature provides a USB attached Swiss, French/German #150 /F/ G keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#5968)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5969) - USB Keyboard-Norwegian

(No Longer Available as of August 31, 2012)

This feature provides a USB attached Norwegian #155 keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#5969)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5970) - USB Keyboard-Dutch

(No Longer Available as of August 31, 2012)

This feature provides a USB attached Dutch #143 keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#5970)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5971) - USB Keyboard-Portuguese

(No Longer Available as of August 31, 2012)

This feature provides a USB attached Portuguese #163 keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#5971)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5972) - USB Keybd-Greek

(No Longer Available as of August 31, 2012)

This feature provides a USB attached Greek #319 keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#5972)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5973) - USB Keybd-Hebrew

(No Longer Available as of August 31, 2012)

This feature provides a USB attached Hebrew #212 keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#5973)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5974) - USB Keybd-Polish

(No Longer Available as of August 31, 2012)

This feature provides a USB attached Polish #214 keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#5974)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5975) - USB Keybd-Slovakian

(No Longer Available as of August 31, 2012)

This feature provides a USB attached Slovakian #245 keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#5975)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5976) - USB Keybd-Czech

(No Longer Available as of August 31, 2012)

This feature provides a USB attached Czech #243 keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#5976)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5977) - USB Keybd-Turkish

(No Longer Available as of August 31, 2012)

This feature provides a USB attached Turkish #179 keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#5977)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5978) - USB Keyboard-LA Spanish

(No Longer Available as of August 31, 2012)

This feature provides a USB attached LA Spanish #171 keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#5978)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5979) - USB Keybd-Arabic

(No Longer Available as of August 31, 2012)

This feature provides a USB attached Arabic #253 keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#5979)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5980) - USB Keybd-Thailand

(No Longer Available as of August 31, 2012)

This feature provides a USB attached Thai #191 keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#5980)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5981) - USB Keybd-Russian

(No Longer Available as of August 31, 2012)

This feature provides a USB attached Russian #443 keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#5981)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5982) - USB Keybd-Russian

(No Longer Available as of August 31, 2012)

This feature provides a USB attached Slovenian #234 keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#5982)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#5983) - USB Keybd-US English Euro

(No Longer Available as of August 31, 2012)

This feature provides a USB attached US English Euro #103P keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#5983)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#6001) - SPCN Power Cable - 2m

(No longer available as of December 01, 2008)

#6001 is a 2M SPCN Power Control Cable.

  • For 9405-520: (#6001)
    • Minimum required: 0
    • Maximum allowed: 10 (Initial order maximum: 10)
    • OS level required:
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#6006) - SPCN Power Cable - 3m

#6006 is a 3M SPCN Power Control Cable.

  • Attributes provided: 3m power control cable
  • For 9405-520: (#6006)
    • Minimum required: 0
    • Maximum allowed: 10 (Initial order maximum: 10)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#6007) - SPCN Power Cable - 15m

#6007 is a 15M SPCN Power Control Cable.

  • For 9405-520: (#6007)
    • Minimum required: 0
    • Maximum allowed: 10 (Initial order maximum: 10)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#6008) - SPCN Power Cable - 6m

(No Longer Available as of October 2, 2009)

#6008 is a 6M SPCN Power Control Cable.

  • For 9405-520: (#6008)
    • Minimum required: 0
    • Maximum allowed: 10 (Initial order maximum: 10)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#6029) - SPCN Power Cable - 30m

(No longer available as of December 01, 2008)

#6029 is a 30M SPCN Power Control Cable.

  • For 9405-520: (#6029)
    • Minimum required: 0
    • Maximum allowed: 10 (Initial order maximum: 10)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#6068) - Opt Front Door for 1.8m Rack

#6068 provides an attractive black full height rack door on the #0551 iSeries 1.8m Rack. The door is steel, with a perforated flat front surface. The perforation pattern extends from the bottom to the top of the door to enhance ventilation and provide some visibility into the rack.

Additional option: #6580 Optional Rack Security Kit

  • Attributes provided: Front Door
  • Attributes required: #0551 iSeries 1.8m Rack
  • For 9405-520: (#6068)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#6069) - Opt Front Door for 2.0m Rack

#6069 provides an attractive black full height rack door on the #0553 2.0m Rack. The door is steel, with a perforated flat front surface. The perforation pattern extends from the bottom to the top of the door to enhance ventilation and provide some visibility into the rack.

Additional option: #6580 Optional Rack Security Kit

  • Attributes provided: Front Door
  • Attributes required: #0553 2.0m Rack
  • For 9405-520: (#6069)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#6134) - 60GB 8mm Tape Unit

(No longer available as of June 15, 2005)

The #6134 is a 8mm, 0.25-inch half-high, 16-bit, internal Auto-docking tape drive, usable with a non-OS/400 operating system only. This drive provides a high capacity tape drive for save/ restore and archiving functions. This tape drive uses IBM 8mm data cartridges and is compression capable, providing a capacity of up to 150 GB.

Characteristics:

  • Capacity: 60 GB native mode.
  • Compression Mode, 150 GB (typical)
  • Form Factor: 5.25-inch Half-high
  • Media: IBM 8mm Data Cartridge with Smart Clean Technology
  • Technology: Helical Scan, Rotating Head
  • Operation: Streaming
  • Data Transfer Rate: 12MB/Sec. Native Mode, 30MB/Sec typical)
  • Interface: SCSI-2 16-bit Low Voltage Differential(LVD) / Single-ended (SE) Asynchronous/Synchronous
  • Attributes provided: 60/150GB 16-bit 8mm Internal Tape Drive
  • Attributes required: One 1.6-inch(41mm) half-high media bay and one PCI SCSI controller.
  • For 9405-520: (#6134)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#6204) - Differential SCSI Adapter

(No longer available as of June 24, 2005)

The #6204 is a SCSI-2 differential adapter with a maximum data transfer rate of 40 MBytes per second. This adapter has the capability to be plugged into the newer +3.3 volt PCI slots as well as the older +5 volt PCI slots. The #6204 allows connection to external differential SCSI-2 F/W or Ultra SCSI type devices up to 25 meters away. The #6204 will negotiate with each external device and transfer data at the fastest SCSI data transfer rate capable by the external device. Check system sales pages as to which external differential subsystems are supported.

The adapter conforms to SCSI-2 standard and the Fast-20 (Ultra) documentation. Industry standard 68 pin connectors are incorporated (SCSI "P" connector definition of X3T9.2/90-048).

  • Attributes provided: 15 external SCSI-2 addresses
  • Attributes required: 1 PCI slot.
  • For 9405-520: (#6204)
    • Minimum required: 0
    • Maximum allowed: 10 (Initial order maximum: 10)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#6246) - 1.8m Rack Trim Kit

(No Longer Available as of February 9, 2010)

This feature provides a decorative trim kit for the front of an #0551 1.8m Rack.

Early versions of #0551 did not have #6246 associated with it, even though a 1.8m Rack Trim Kit was installed on the #0551 rack.

  • Attributes provided: Decorative trim kit
  • Attributes required: #0551 1.8m Rack
  • For 9405-520: (#6246)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#6247) - 2.0m Rack Trim Kit

(No Longer Available as of February 9, 2010)

#6247 provides a decorative trim kit for the front of a #0553 2.0m Rack.

  • Attributes provided: Decorative trim kit
  • Attributes required: #0553 2.0m Rack
  • For 9405-520: (#6247)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#6248) - 1.8m Rack Acoustic Doors

#6248 provides front and rear doors for use with the #0551 1.8m Rack. This door kit provides additional acoustic dampening for use where a quieter environment is desired. #6248 results in a larger footprint and requires additional space.

  • Attributes provided: Acoustic Door Kit
  • Attributes required: #0551 1.8m Rack
  • For 9405-520: (#6248)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#6249) - 2.0m Rack Acoustic Doors

#6249 provides front and rear doors for use with the #0553 2.0m Rack. This door kit provides additional acoustic dampening for use where a quieter environment is desired. #6249 results in a larger footprint and requires additional space.

  • Attributes provided: Acoustic Door Kit
  • Attributes required: #0553 2.0m Rack
  • For 9405-520: (#6249)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#6258) - 36GB 4mm Tape Unit

(No longer available as of May 29, 2009)

The #6258 4mm 36/72GB tape drive is an internal, bolt-in, 5.25-inch, half-high, single ended SCSI-2 tape drive that provides a high-capacity for save/restore functions.

Characteristics:

  • Capacity: 36GB native mode, 72GB (typical) compression mode
  • Form Factor: 5.25-inch, half-high
  • Media: IBM 4mm DAT72 data cartridge
  • Technology: Helical scan, rotating head
  • Operation: Streaming
  • Data Transfer Rate: 3MBps native mode, 6MBps (typical) compresstion mode
  • Interface: SCSI-2 (single ended)
  • Compatibility: Read/Write of DDS3, DDS4 and DAT72 media
  • Attributes provided: 4mm 36/72GB internal bolt-in tape drive
  • Attributes required: One 5.25-inch half-high media bay, #0140 (Logical Partitioning Specify) and (#0142 (Linux Partition Specify) and/or #0145 (AIX Partition Specify))
  • For 9405-520: (#6258)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R4, or later, AIX 5L for Power V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#6263) - 1.8m Rack Trim Kit

This feature provides a decorative trim kit for the front of feature number 0551 (19 inch 1.8m Rack).

  • Attributes provided: Decorative trim kit
  • Attributes required: #0551 19 inch 1.8m Rack
  • For 9405-520: (#6263)
    • Minimum required: 0
    • Maximum allowed: 999 (Initial order maximum: 0)
    • OS level required: n/a
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes
    • Return parts MES: No

(#6272) - 2.0m Rack Trim Kit

This feature provides a decorative trim kit for the front of feature number 0553 (19 inch 2.0m Rack).

  • Attributes provided: Decorative trim kit
  • Attributes required: #0553 19 inch 2.0 meter Rack
  • For 9405-520: (#6272)
    • Minimum required: 0
    • Maximum allowed: 999 (Initial order maximum: 0)
    • OS level required: n/a
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes
    • Return parts MES: No

(#6279) - 160GB VXA-320 Tape Drive

(No longer available as of May 08, 2007)

#6279 160GB VXA-320 Tape Drive is a 5.25-inch, half-high, Ultra2 SCSI tape drive, which provides a high capacity for save/restore and archive functions. This tape drive uses VXA tape data cartridges and is compression capable, providing a capacity of up to 320GB.

Characteristics:

  • Capacity: 160GB native mode, 320GB (typical) compression mode
  • Form Factor: 5.25-inch, half-high
  • Mounting type: bolt-in. Power/SCSI connection cable will also be shipped (no unique cable feature required to be ordered).
  • Media: uses VXA tape data cartridges
  • Technology: Helical scan, rotating head
  • Operation: Streaming
  • Data Transfer Rate: 12MBps native mode, 24MBps (typical) compression
  • Interface: Ultra2 SCSI, 16-bit (wide), LVD and SE compatible
  • Compatibility: VXA-320 and VXA-2 (read/write), VXA-1 (read only)
  • Attributes provided: One 160GB VXA-320 tape drive
  • Attributes required: One half-high media bay
  • For 9405-520: (#6279)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE Linux Enterprise Server 9 for POWER, or later, AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#6312) - Quad Digital Trunk Adapter

(No Longer Available as of August 28, 2009)

The Quad Digital Trunk Telephony PCI Adapter is a highly integrated, intelligent I/O adapter designed for use in computer telephony applications. The adapter is a 4-port, full length, universal PCI 2.2 compliant adapter. It performs voice processing for up to four T1 or E1 digital trunks, providing connectivity for 96 (T1) or 120 (E1) voice channels in a single PCI slot. The adapter is made up of two separate cards. A base card that interfaces with the host system and performs telephony processing functions, and a daughter card that provides the physical interface to the switch. The voice processing function is provided by WebSphere Voice Response for AIX LPP with Direct Talk Technology.

In conjunction with this adapter, network attachment cables using industry standard RJ-48 connector can be obtained from commercial cable suppliers in a variety of lengths to suit the particular installation. Additional information about these cables can be obtained by referring to this adapter's Installation and User's Guide.

Note: When two to four Quad Digital Trunk Telephony PCI Adapters (#6312) are ordered and planned to be used in a single partition, 4-position Int Bus Cable (#2877) is required. When more than four Quad Digital Trunk Telephony PCI Adapters (#6312) are ordered and planned to be used in a single partition, the 8-Position H.100 Bus Cable (#4353) is required.

Limitations: The Quad Digital Trunk Telephony PCI Adapter (#6312) cannot reside in the same system with the IBM ARTIC960RxD Quad Digital Trunk PCI Adapter (#6310). The Quad Digital Trunk Telephony PCI Adapter (#6312) is only supported in machines running in a full system partition.

  • Attributes provided: Connection of one to four T1/E1 Trunk lines.
  • Attributes required: One available PCI slot, WebSphere Voice Response for AIX LPP application software, #0140 (Logical Partitioning Specify) and #0145 (AIX Partition Specify).
  • For 9405-520: (#6312)
    • Minimum required: 0
    • Maximum allowed: 19 (Initial order maximum: 19)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#6417) - HSL-2/RIO-G Bus Adapter

The #6417 feature allows existing HSL and optical HSL connected towers the option of switching to copper HSL-2/RIO-G connectivity. The #6417 has two HSL-2/RIO-G ports and provides connectivity for #0595, #5094, #5095, #5294 and #8294 PCI expansion towers and expansion units.

  • Attributes provided: Two ports of HSL-2/RIO-G connectivity
  • Attributes required: HSL adapter slot in PCI expansion tower/unit
  • For 9405-520: (#6417)
    • Minimum required: 0
    • Maximum allowed: 6 (Initial order maximum: 0)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#6455) - 14-Ft 250V/10A Power Cord

(No longer available as of January 31, 2008)

#6455 is a 14-foot 250V/10A power cord that distributes power from a wall outlet to a system unit. #6455 has a type 5 plug and a right-angle IEC320 C13 connector.

  • For 9405-520: (#6455)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: n/a
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#6458) - 14-Ft Int 250V/10A Pwr Cd

#6458 power cord is used from a racked device to a #5160/#5161/ #5162/5163/#7188/#7109 Power Distribution Unit in that same rack.

  • Attributes provided: Power distribution from PDU to racked device
  • Attributes required: Rack with PDU and racked device
  • For 9405-520: (#6458)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#6459) - 12-Ft 250V/10A RA Pwr Cd

(No Longer Available as of November 26, 2010)

#6459 is a 12-foot 250V/10A power cord that distributes power from a Power Distribution Unit to a drawer in an expansion tower/ rack. #6459 has an IEC320 C14 plug and a right-angle IEC320 C13 connector.

  • For 9405-520: (#6459)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: n/a
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#6460) - 14-Ft 125V/15A Power Cord

#6460 is a 14-foot 125V/15A power cord that distributes power from a wall outlet to a system unit. #6460 has a Type 4 plug and an IEC320 C13 connector.

  • For 9405-520: (#6460)
    • Minimum required: 0
    • Maximum allowed: 26 (Initial order maximum: 2)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#6469) - 14-Ft 250V/15A Power Cord

#6469 is a 14-foot 250V/15A power cord that distributes power from a wall outlet to a system unit. #6469 has a type 5 plug and an IEC320 C13 connector.

  • For 9405-520: (#6469)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: n/a
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#6470) - 6-Ft 125V/15A Power Cord

#6470 is a 6-FT 125V/15A power cable that distributes power from a power source to a system unit or an expansion unit. #6470 has a Type 4 plug and a IEC320 C13 connector.

  • For 9405-520: (#6470)
    • Minimum required: 0
    • Maximum allowed: 26 (Initial order maximum: 26)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#6487) - 6-Ft 250V/15A Power Cord

(No Longer Available as of May 27, 2011)

#6487 is a 6-foot 250V/15A power cord which distributes power to a system unit or expansion tower/rack. #6487 has a Type 5 plug and a IEC320 C13 connector.

  • For 9405-520: (#6487)
    • Minimum required: 0
    • Maximum allowed: 26 (Initial order maximum: 26)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#6492) - 14-Ft 1PH/48-60A Pwr Cord

#6492 is a 14-FT/4.3m 200-240V/48A power cord with a Type 46 plug which distributes power from a power source to a Power Distribution Unit.

  • For 9405-520: (#6492)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#6497) - 6-Ft 250V/15A Power Cord

#6497 is a 6-foot 250V/15A power cord which distributes power to a system unit or expansion tower/rack. #6497 has a Type 10 plug and a IEC320 C13 connector.

  • For 9405-520: (#6497)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#6498) - 6-Ft 250V/15A Power Cord

(No longer available as of January 31, 2008)

#6498 is a 6-foot 250V/15A power cord which distributes power to a system unit or expansion tower/rack. #6498 has a Type 34 plug and a IEC320 C13 connector.

  • For 9405-520: (#6498)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#6574) - 4-Disk Slot Exp - Base Ctlr

(No Longer Available as of August 28, 2009)

The #6574 is a disk backplane feature that enables the second set of four disk unit slots in the system unit to be used.

Disk units plugged into the #6574 are controlled by the integrated base disk controller with or without #5709/#5727 write cache.

  • Attributes provided: Backplane to attach up to four disk units
  • Attributes required: Available disk unit backplane connection slot
  • For 9405-520: (#6574)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#6580) - Optional Rack Security Kit

This feature provides hardware that can be added to a rack to prevent unauthorized access. It includes keyed front and rear locks for the #0551 and #0553 rack doors. It also includes two sliding bars that mount inside the left and right rack side panels. The sliding bars are accessible when the rack rear door is open. They can be moved to a position that disables the external latches on the rack side panels, and prevents removal of the side panels.

  • Attributes provided: Locking hardware for rack doors and side panels
  • Attributes required: #0551 1.8m Rack or #0553 2.0m Rack
  • For 9405-520: (#6580)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#6585) - DASD Locking Kit

(No longer available as of January 01, 2009)

Provides a locking mechanism which secures up to four disk units in the deskside system (#7885). Each #6585 kit can secure 4 disk units in the system unit. When #6585 is installed and secured with a user- provided padlock, the disk units cannot be removed easily.

  • Attributes provided: Disk Unit security
  • For 9405-520: (#6585)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 0)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#6586) - Modem Tray for 19-Inch Rack

This feature provides hardware for installing one or two modems in a 19-inch rack. The modem tray occupies 1U of rack space when it is mounted in the front of the rack. It provides a secure location in the rack for external modems such as the ones attached to the Hardware Management Console.

  • Attributes provided: Space for two modems
  • Attributes required: 19-inch rack with 1U rack space available
  • For 9405-520: (#6586)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 0)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#6587) - Rear Cover

(No longer available as of January 01, 2009)

A decorative rear cover which has sound deadening capability. This cover is for servers which do not have external I/O attached to an HSL loop. The cover can not be used if HSL cables are attached to the server.

  • For 9405-520: (#6587)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#6594) - 4-Disk Slot Exp-PCI-X Ctlr

(No Longer Available as of August 28, 2009)

The #6594 is a disk backplane feature that enables the second four disk slots to be driven by a separate disk controller plugged into a system unit PCI slot.

Disk units plugged into the #6594 are controlled by a disk controller plugged into a CEC PCI slot. The #6594 is not usable by either the embedded system unit disk controller or by a #5709/#5727.

A #6594 can be used for obtaining RAID or disk mirroring protection or for enabling these drives in another system partition.

  • Attributes provided: Backplane to attach up to four disk units
  • Attributes required: Available disk unit backplane connection slot
  • For 9405-520: (#6594)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

    When installed in a model 520 CEC, only short PCI cards can be plugged into slot C05.

(#6598) - Disk Slot Filler (Qty 4)

Provides covers for installation in disk slots which have been emptied after the system unit or disk unit expansion unit was shipped from IBM. Four covers are shipped with each #6598.

When shipped from IBM, all disk slots are filled with either disk drives or slot fillers. If a disk is removed, IBM recommends the slot be refilled with either another disk drive, or a disk slot filler. Filling the disk slot helps ensure proper air-flow for cooling and helps maintain EMI compliance.

On initial orders, one #6598 is defaulted when one or more #0140 Logical Partitioning Specify is also on the order.

  • Attributes provided: Four disk slot covers
  • Attributes required: Empty disk slots
  • For 9405-520: (#6598)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: 250)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

    May be installed in model 520 system unit and in #5786 and #5787 expansion units.

(#6654) - 14-Ft 1PH/24-30A Pwr Cord

#6654 is a 14-FT/4.3m 200-240V/24A locking power cord with a Type 12 plug which distributes power from a power source to a Power Distribution Unit.

  • For 9405-520: (#6654)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: n/a
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#6655) - 14-Ft 1PH/24-30A WR Pwr Cord

#6655 is a 14-FT/4.3m 200-240V/24A water-resistant power cord with a Type 40 plug which distributes power from a power source to a Power Distribution Unit.

  • For 9405-520: (#6655)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: n/a
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#6664) - 7-Ft 200V PDU Power Cable

(No longer available as of December 01, 2007)

This feature provides a power cord for connecting an I/O drawer to an IBM PDU within a rack. The power connector to the drawer is at a 90 degree angle to the power cord. The length of this cable (7 feet) may not meet cabling requirements in all rack locations.

  • Attributes provided: Right Angle power cable
  • Attributes required: FC#5790
  • For 9405-520: (#6664)
    • Minimum required: 0
    • Maximum allowed: 12 (Initial order maximum: 0)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#6671) - 9Ft IEC 320 C13/14 PDU Cord

This power cord is used from a racked device to a power distribution unit in that same rack. This cord replaces the #1422 PDU cord . The #6671 is a better match for the smaller #0554 11U and #0555 25U racks than the #1422.

  • For 9405-520: (#6671)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 0)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#6672) - 5Ft IEC 320 C13/14 PDU Cord

This power cord is used from a racked device to a Power Distribution Unit in that same rack. This cord is primarily intended for use with the smaller #0554 11U and #0555 25U racks. Care must be taken before ordering this cord to ensure it has sufficient length, especially when used with a drawer that slides out for concurrent maintenance service.

  • For 9405-520: (#6672)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 0)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#6800) - PCI 1Gbps Ethernet IOA

Provides a PCI-X IOA which does not require an IOP and allows a system running i5/OS to attach to IEEE standard 802.3Z high speed (1Gbps) Ethernet LANs. The #6800 adapter supports a multimode fiber interface with a 62.5 micron or 50.0 micron cable requirement. The adapter has a duplex LC fiber-optic connector for attachment to customer-supplied cabling.

The #6800 only supports TCP/IP and requires an intervening switch/ hub/router when connection to 100Mbps or 10Mbps networks.

#6800, #0620, and #5700 are physically the same adapter card but have different feature numbers that denote to IBM configurator tools whether or not an IOP is required.

  • Attributes provided: 1000/100/10 Ethernet LAN Interface
  • Attributes required: One short or long, 3.3V or 5V PCI-X slot
  • For 9405-520: (#6800)
    • Minimum required: 0
    • Maximum allowed: 36 (Initial order maximum: 0)
    • OS level required: i5/OS V5R4 with V5R4M0 LIC, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#6801) - PCI 1Gbps Ethernet UTP IOA

Provides a PCI-X IOA which does not require an IOP and allows a system running i5/OS to attach to IEEE standard 802.3ab high speed (1Gbps) Ethernet LANs. The adapter supports a UTP CAT 5 media interface.

The #6801 only supports TCP/IP and requires an intervening switch/ hub/router when connecting to 1Gbps networks. It does not require a switch/hub/router for 100Mbps or 10Mbps networks.

#6801, #0621, and #5701 are physically the same adapter card but have different feature numbers that denote to IBM configurator tools whether or not an IOP is required.

  • Attributes provided: 1000/100/10 Ethernet LAN Interface
  • Attributes required: One short or long, 3.3V or 5V PCI-X slot
  • For 9405-520: (#6801)
    • Minimum required: 0
    • Maximum allowed: 36 (Initial order maximum: 0)
    • OS level required: i5/OS V5R4 with V5R4M0 LIC, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#6803) - PCI WAN for ECS

The #6803 is a WAN w/modem adapter which provides connectivity for IBM Electronic Customer Support (ECS) only. This feature is the non-CIM (Complex Impedance Matching) version offered in all countries except Australia and New Zealand. #6803 is functionally equivalent to #0614/#2793/#9793, but #6803 indicates to IBM configurator tools that the IOA is being used by i5/OS in an IOP-less mode. When in IOP-less mode the adapter function is restricted to communicating to IBM ECS on port 0 (modem port). Port 1 is the RVX port and is not supported in an IOP-less mode.

Port 0 supports V.92 56K PPP, V.92 data modem and V.44 data compression. Port 0 does not provide Synchronous modem capabilities (SDLC and Synchronous PPP).

Select one of the following cables to attach to port 0 (modem port):

  • #1010 Modem Cable - Austria
  • #1011 Modem Cable - Belgium
  • #1012 Modem Cable - Africa
  • #1013 Modem Cable - Israel
  • #1014 Modem Cable - Italy
  • #1015 Modem Cable - France
  • #1016 Modem Cable - Germany
  • #1017 Modem Cable - UK
  • #1018 Modem Cable - Iceland/Sweden
  • #1020 Modem Cable - HK/NZ
  • #1021 Modem Cable - Fin/Nor
  • #1022 Modem Cable - Netherlands
  • #1023 Modem Cable - Swiss
  • #1024 Modem Cable - Denmark
  • #1025 Modem Cable - US/Canada

The #6803 does not support the remote ring indicate function. This feature has country specific usage.

  • Attributes provided: One integrated modem port for communication with IBM ECS
  • Attributes required: One PCI slot (3 volt)
  • For 9405-520: (#6803)
    • Minimum required: 0
    • Maximum allowed: 69 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3 with V5R3M5 Machine Code, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#6805) - PCI 2-Line WAN IOA No IOP

#6805 is a WAN IOA that supports up to two multiple protocol communications (RVX) ports when one or two of the following cables are attached:

  • #0348 - V.24/EIA232 20-Ft PCI Cable
  • #0349 - V.24/EIA232 50-Ft PCI Cable (support only, not orderable)
  • #0353 - V.35 20-Ft PCI Cable
  • #0354 - V.35 50-Ft PCI Cable
  • #0355 - V.35 80-Ft PCI Cable (support only, not orderable)
  • #0356 - V.36 20-Ft PCI Cable
  • #0358 - V.36 80-Ft PCI Cable (support only, not orderable)
  • #0359 - X.21 20-Ft PCI Cable
  • #0360 - X.21 50-Ft PCI Cable
  • #0365 - V.24/EIA232 80-Ft PCI Cable
  • #0367 - Operations Console PCI Cable

Note: The #0367 cable ships with a 25 pin to 9 pin adapter.

  • Multiple #0367 cables may be ordered (but only one per #6805) to serve as consoles for secondary partitions when Logical Partitioning is utilized.

When #6805 is selected to support ECS, one of following cables must be specified:

  • #0348 V.24/EIA232 20-Ft PCI Cable
  • #0349 V.24/EIA232 50-Ft PCI Cable (support only, not orderable)
  • #0365 V.24/EIA232 80-Ft PCI Cable

#6805 does not make use of an IOP.

#6805 does not support remote power-on.

#6805 does not support SNA communications except through the i5/ OS V5R4 Enterprise Extender function.

#6805, #2742, and #0613 are physically the same adapter card, but have different feature numbers that denote to IBM configuration tools whether or not an IOP is required.

  • Attributes provided: two RVX comm ports
  • Attributes required: one 3v PCI/PCI-X slot
  • For 9405-520: (#6805)
    • Minimum required: 0
    • Maximum allowed: 90 (Initial order maximum: 0)
    • OS level required: i5/OS V5R4 with V5R4M5 Machine Code, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#6808) - PCI 4-Modem WAN IOA No IOP

(No Longer Available as of April 29, 2011)

The #6808 is a four-line WAN modem adapter, with four RJ-11 ports, supports V.92 56K Async SLIP/PPP and V.34 Fax applications at data rates up to 33.6K via integrated modems. Connection to the V.92 ports is via telephone cable. The V.92 functions offer increased upload throughput, improved V.44 data compression, and shortened modem synchronization periods.

The call waiting and modem on hold functions associated with V.92 are not supported.

Remote power on via ring-indicator and SDLC are not supported.

#6808 does not support SNA communications except through the i5/ OS V5R4 Enterprise Extender function.

#6808 does not have complex impedance matching (CIM).

This version of the four-line WAN modem adapter does not require an I/O processor.

#6808 does not make use of an IOP.

#6808, #2805, and #0616 are physically the same adapter card, but have different feature numbers that denote to IBM configuration tools whether or not an IOP is required.

A minimum of one modem cable must be ordered for each #6808. All modem cables installed on a system must be the same feature number.

  • #1010 Modem Cable - Austria
  • #1011 Modem Cable - Belgium
  • #1012 Modem Cable - Africa
  • #1013 Modem Cable - Israel
  • #1014 Modem Cable - Italy
  • #1015 Modem Cable - France
  • #1016 Modem Cable - Germany
  • #1017 Modem Cable - UK
  • #1018 Modem Cable - Iceland/Sweden
  • #1020 Modem Cable - HK/NZ
  • #1021 Modem Cable - Fin/Nor
  • #1022 Modem Cable - Netherlands
  • #1023 Modem Cable - Swiss
  • #1024 Modem Cable - Denmark
  • #1025 Modem Cable - US/Canada
  • Attributes provided: four WAN ports
  • Attributes required: one PCI slot
  • For 9405-520: (#6808)
    • Minimum required: 0
    • Maximum allowed: 47 (Initial order maximum: 0)
    • OS level required: i5/OS V5R4 with V5R4M5 Machine Code, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#6833) - PCI 2-Line WAN w/Modem NoIOP

(No longer available as of May 29, 2009)

The #6833 is a 2-line/port WAN w/modem adapter. This feature is the non-CIM (Complex Impedance Matching) version offered in all countries except Australia and New Zealand.

#6833/#9933 is physically the same card as #0614/#2793/#9793, but #6833/#9933 indicates to IBM configurator tools that the IOA is being used by i5/OS in an IOP-less mode. #6833/#9933 is physically the same card as the IOP-less #6803/#9493, but with i5/OS V5R4 with V5R4M5 machine code, additional function is provided, including the use of the second communication port, and a separate feature code is used to denote this.

Port 0 is the modem port and supports V.92 56K Async PPP, V.92 data modem, V.44 data compression, V.34 FAX modem and FAX functions, such as ECM and 2D/1D conversion. Port 0 does not provide Sync modem capabilities (SDLC and Sync PPP).

Port 1 is the RVX port and supports multiple communications protocols, including synchronous operations.

Select one of the following cables to attach to port 0(modem port):

  • #1010 Modem Cable - Austria
  • #1011 Modem Cable - Belgium
  • #1012 Modem Cable - Africa
  • #1013 Modem Cable - Israel
  • #1014 Modem Cable - Italy
  • #1015 Modem Cable - France
  • #1016 Modem Cable - Germany
  • #1017 Modem Cable - UK
  • #1018 Modem Cable - Iceland/Sweden
  • #1020 Modem Cable - HK/NZ
  • #1021 Modem Cable - Fin/Nor
  • #1022 Modem Cable - Netherlands
  • #1023 Modem Cable - Swiss
  • #1024 Modem Cable - Denmark
  • #1025 Modem Cable - US/Canada

Select one of the following cables to attach to port 1(RVX port):

  • #0348 - V.24/EIA232 20-Ft PCI Cable
  • #0353 - V.35 20-Ft PCI Cable
  • #0356 - V.36 20-Ft PCI Cable
  • #0359 - X.21 20-Ft PCI Cable
  • #0367 - Operations Console PCI Cable (ships with a 25 pin to 9 pin adapter)
    • Multiple #0367 cables can be ordered but only one per #2793) to serve as consoles for secondary partitions when Logical Partitioning is utilized.

ECS is supported from both the modem port, and the RVX port. The following cable is required to support ECS from the RVX port:

  • #0348 - V.24/EIA232 20-Ft PCI Cable

The #6833 does not support the remote ring indicate function.

#6833 does not support SNA communications except through the i5/ OS V5R4 Enterprise Extender function.

  • Attributes provided: One RVX port and one integrated modem port
  • Attributes required: One PCI slot (3 volt)
  • For 9405-520: (#6833)
    • Minimum required: 0
    • Maximum allowed: 95 (Initial order maximum: 0)
    • OS level required: i5/OS V5R4 with V5R4M5 Machine Code, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#7109) - Intelligent PDU Plus

This feature is for an intelligent AC power distribution unit (PDU+) that will allow the user to monitor the amount of power being used by the devices that are plugged in to this PDU+. This AC power distribution unit provides twelve C13 power outlets. It receives power through a UTG0247 connector. It can be used for many different countries and applications by varying the separately ordered PDU to Wall Power Cord.

Each PDU requires one PDU to Wall Power Cord. Supported power cords include the following features:

  • #6489
  • #6491
  • #6492
  • #6653
  • #6654
  • #6655
  • #6656
  • #6657
  • #6658
  • Attributes provided: Twelve C13 outlets with Power Monitoring capability
  • Attributes required: PDU to Wall power cord
  • For 9405-520: (#7109)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 0)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#7140) - 520 Express Configuration

(No longer available as of July 08, 2008)

Provides an Express Configuration for a model 9405-520 with Server Solution Package #0970 and processor feature #8325

  • For 9405-520: (#7140)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3 with V5R3M5 Machine Code, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: N/A

(#7141) - 520 Express Configuration

(No longer available as of July 08, 2008)

Provides an Express Configuration for a model 9405-520 with Server Solution Package #0970 and processor feature #8325

  • For 9405-520: (#7141)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3 with V5R3M5 Machine Code, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: N/A

(#7142) - 520 Express Configuration

(No longer available as of July 08, 2008)

Provides an Express Configuration for a model 9405-520 with Server Solution Package #0970 and processor feature #8325

  • For 9405-520: (#7142)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3 with V5R3M5 Machine Code, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: N/A

(#7143) - 520 Express Configuration

(No longer available as of July 08, 2008)

Provides an Express Configuration for a model 9405-520 with Server Solution Package #0970 and processor feature #8327

  • For 9405-520: (#7143)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3 with V5R3M5 Machine Code, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#7144) - 520 Express Configuration

(No longer available as of July 08, 2008)

Provides an Express Configuration for a model 9405-520 with Server Solution Package #0970 and processor feature #8327

  • For 9405-520: (#7144)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3 with V5R3M5 Machine Code, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: N/A

(#7148) - 520 Express Configuration

(No longer available as of July 08, 2008)

Provides an Express Configuration for a model 9405-520 with Server Solution Package #0970 and processor feature #8327

  • For 9405-520: (#7148)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3 with V5R3M5 Machine Code, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#7152) - 520 Express Configuration

(No longer available as of July 08, 2008)

Provides an Express Configuration for a model 9405-520 with Server Solution Package #0970 and processor feature #8327

  • For 9405-520: (#7152)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3 with V5R3M5 Machine Code, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#7180) - Acoustic Front Door

(No longer available as of January 01, 2009)

Provides a front door which has acoustic dampening capabilities for the deskside system unit. #7180 is functionally equivalent to #7753 Acoustic Front Door, but has the System i5 name and accent color.

  • Attributes provided: Acoustic Front Door
  • Attributes required: Deskside System Unit
  • For 9405-520: (#7180)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#7181) - Easy-Access Front Cover

(No longer available as of January 01, 2009)

Provides a front cover which has an easy access bezel for the deskside system unit.

  • Attributes provided: Front Cover with Easy Access Bezel
  • Attributes required: Deskside System Unit
  • For 9405-520: (#7181)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#7182) - Rack Mount

(No longer available as of January 01, 2009)

Indicates this is a rack-mounted system unit. System will ship with IBM mounting rails for installation in an IBM standard 19-inch rack. Rails are fixed at 28 inch depth and a front bezel is included. Add #7198 Adjustable Depth Rack Rails to #7182 if adjustable length rails are needed.

  • Attributes provided: Rack mounted system unit
  • Attributes required: Rack mounted system unit
  • For 9405-520: (#7182)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#7188) - Power Distribution Unit

An AC Power Distribution Unit (PDU) which mounts in an iSeries rack and provides twelve C13 power outlets. The #7188 has six 16A circuit breakers, with two power outlets per circuit breaker. System units and/or expansion units must use a power cord with a C14 plug to connect to the #7188.

One of the following line cords must be used to distribute power from a wall outlet to the #7188:

  • #6489 - 14-Ft 3PH/24A Power Cord
  • #6491 - 14-Ft 1PH/63A Pwr Cord
  • #6492 - 14-Ft 1PH/48-60A Pwr Cord
  • #6653 - 14-Ft 3PH/16A Power Cord
  • #6654 - 14-Ft 1PH/24-30A Pwr Cord
  • #6655 - 14-Ft 1PH/24-30A WR Pwr Cord
  • #6656 - 14-Ft 1PH/32A Power Cord
  • #6657 - 14-Ft 1PH/24A Power Cord
  • #6658 - 14-Ft 1PH/24A Pwr Cd-Korea
  • Attributes provided: Power Distribution Unit with Twelve C13 power outlets.
  • Attributes required: iSeries Rack
  • For 9405-520: (#7188)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#7198) - Adjustable Depth Rack Rails

(No longer available as of January 01, 2009)

Provides rails that are adjustable to a depth of 29.5 inches for mounting a system unit in an OEM rack. The fixed depth rails provided in the prerequisite Rack Mount specify, are replaced by the adjustable rails. The adjustable rails are installed by the client.

  • Attributes provided: Ability to mount the system unit in an OEM rack
  • Attributes required: Rack mounted system unit
  • For 9405-520: (#7198)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 0)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#7307) - Dual I/O Unit Enclosure

(No Longer Available as of November 26, 2010)

The #7307 enclosure provides the mounting hardware, with adjustable rails, required to install a #5790 I/O drawer in a #0551, #0553, #0554, or #0555 rack. The enclosure can accommodate two #5790 drawers, side by side, but it may also be used with only one #5790 drawer installed.

The #7307 and #7311 are functionally equivalent except the #7307 can be used in the #0554 and #0555 racks and has rails adjustable to 29.25 inches depth.

  • Attributes provided: Rack mounting for two #5790 drawers
  • Attributes required: Four EIA units of rack space in a #0551, #0553, #0554 or #0555 rack
  • For 9405-520: (#7307)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 0)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#7311) - Dual I/O Unit Enclosure

(No longer available as of June 01, 2006)

The #7311 enclosure provides the mounting hardware required to install a #5790 I/O drawer in a #0551 or #0553 rack. The enclosure can accommodate two #5790 drawers, side by side, but it may also be used with only one #5790 drawer installed.

  • Attributes provided: Rack mounting for two #5790 drawers
  • Attributes required: Four EIA units of rack space in a #0551or #0553 rack
  • For 9405-520: (#7311)
    • Minimum required: 0
    • Maximum allowed: No max (Initial order maximum: 250)
    • OS level required: n/a
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#7354) - Accelerator for System i5

(No Longer Available as of November 27, 2009)

Provides additional processing capability for the model 520 with Express Configuration Feature #7143.

  • Attributes provided: Additional processing capability
  • Attributes required: Model 520
  • For 9405-520: (#7354)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: I5/OS V5R3 with V5R3M5 Machine Code, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#7390) - Model 520 Express Edition

(No longer available as of June 01, 2006)

#7390 is an Express Edition of a 9405/520 system with server feature #0900 and processor feature #8950.

  • For 9405-520: (#7390)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: N/A

(#7391) - Model 520 Express Edition

(No longer available as of June 01, 2006)

#7391 is an Express Edition of a 9405/520 system with server feature #0900 and processor feature #8950.

  • For 9405-520: (#7391)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: N/A

(#7392) - Model 520 Express Edition

(No longer available as of June 01, 2006)

#7392 is an Express Edition of a 9405/520 system with server feature #0901 and processor feature #8951.

  • For 9405-520: (#7392)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#7393) - Model 520 Express Edition

(No longer available as of June 01, 2006)

#7393 is an Express Edition of a 9405/520 system with server feature #0900 and processor feature #8950.

  • For 9405-520: (#7393)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: N/A

(#7394) - Model 520 Express Edition

(No longer available as of June 01, 2006)

#7394 is an Express Edition of a 9405/520 system with server feature #0901 and processor feature #8951.

  • For 9405-520: (#7394)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#7395) - Model 520 Express Edition

(No longer available as of June 01, 2006)

#7395 is an Express Edition of a 9405-520 system with server feature #0912 and processor feature #8972.

  • For 9405-520: (#7395)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#7396) - Model 520 Express Edition

(No longer available as of June 01, 2006)

#7396 is an Express Edition of a 9405-520 system with server feature #0912 and processor feature #8972.

  • For 9405-520: (#7396)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#7504) - Quantity 150 of #4319

(No longer available as of August 30, 2005)

This feature ships a quantity of 150 #4319 disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records.

Prerequisite: See feature #4319.

  • For 9405-520: (#7504)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R1, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#7508) - Quantity 150 of #4326

(No longer available as of May 08, 2007)

This feature ships a quantity of 150 #4326 disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records.

Prerequisite: See feature #4326.

  • For 9405-520: (#7508)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R2, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#7509) - Quantity 150 of #4327

(No longer available as of February 01, 2009)

This feature ships a quantity of 150 #4327 disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records.

Prerequisite: See feature #4327.

  • For 9405-520: (#7509)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R2, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#7510) - Quantity 150 of #4328

(No Longer Available as of August 28, 2009)

Ships a quantity of 150 #4328 141.12GB disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records.

  • Attributes provided: Quantity of 150 #4328 141.12GB disk units
  • Attributes required: See feature #4328
  • For 9405-520: (#7510)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#7511) - Quantity 150 of #4329

(No longer available as of February 01, 2009)

Ships a quantity of 150 #4329 282.25GB disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records.

  • Attributes provided: Quantity 150 #4329 282.25GB disk units
  • Attributes required: See feature #4329
  • For 9405-520: (#7511)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: i5/OS V5R4, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#7516) - Quantity 150 of #1269

(No longer available as of February 01, 2009)

Ships a quantity of 150 #1269 282.25GB disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records.

  • Attributes provided: Quantity 150 #1269 282.25GB disk units
  • Attributes required: See feature #1269
  • For 9405-520: (#7516)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: i5/OS V5R4, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#7518) - Quantity 150 of #3677

(No Longer Available as of February 8, 2013)

This feature ships a quantity of 150 #3677 disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records.

Prerequisite: See feature #3677.

  • For 9405-520: (#7518)
    • Minimum required: 0
    • (Initial order maximum: 0)
    • OS level required: IBM i 5.4 with V5R4M5 SLIC, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#7519) - Quantity 150 of #3678

(No Longer Available as of February 8, 2013)

This feature ships a quantity of 150 #3678 disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records.

Prerequisite: See feature #3678.

  • For 9405-520: (#7519)
    • Minimum required: 0
    • (Initial order maximum: 0)
    • OS level required: IBM i 5.4 with V5R4M5 SLIC, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#7520) - Quantity 150 of #1266

(No longer available as of May 08, 2007)

Ships a quantity of 150 #1266 35.16GB disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records.

  • Attributes provided: Quantity of 150 #1266 35.16GB disk units
  • Attributes required: See feature #1266
  • For 9405-520: (#7520)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later, AIX 5L for Power V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 4, with quarterly update 3, or later, SUSE Linux Enterprise Server 9 for POWER with service pack 3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#7521) - Quantity 150 of #1267

(No longer available as of February 01, 2009)

Ships a quantity of 150 #1267 70.56GB disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records.

  • Attributes provided: Quantity of 150 #1267 70.56GB disk units
  • Attributes required: See feature #1267
  • For 9405-520: (#7521)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later, AIX 5L for Power V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 4, with quarterly update 3, or later, SUSE Linux Enterprise Server 9 for POWER with service pack 3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#7522) - Quantity 150 of #1268

(No Longer Available as of August 28, 2009)

Ships a quantity of 150 #1268 141.12GB disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records.

  • Attributes provided: Quantity of 150 #1268 141.12GB disk units
  • Attributes required: See feature #1268
  • For 9405-520: (#7522)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later, AIX 5L for Power V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 4, with quarterly update 3, or later, SUSE Linux Enterprise Server 9 for POWER with service pack 3, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#7526) - Quantity 150 of #1295

(No longer available as of May 08, 2007)

Ships a quantity of 150 #1295 146.8GB disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records.

  • Attributes provided: Quantity of 150 #1295 146.8GB disk units
  • Attributes required: See feature #1295
  • For 9405-520: (#7526)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 4, with quarterly update 3, or later, SUSE Linux Enterprise Server 9 for POWER with service pack 3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#7527) - Quantity 150 of #1296

(No longer available as of May 08, 2007)

Ships a quantity of 150 #1296 36.4GB disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records.

  • Attributes provided: Quantity of 150 #1296 36.4GB disk units
  • Attributes required: See feature #1296
  • For 9405-520: (#7527)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 4, with quarterly update 3, or later, SUSE Linux Enterprise Server 9 for POWER with service pack 3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#7528) - Quantity 150 of #1297

(No longer available as of February 01, 2009)

Ships a quantity of 150 #1297 73.4GB disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records.

  • Attributes provided: Quantity of 150 #1297 73.4GB disk units
  • Attributes required: See feature #1297
  • For 9405-520: (#7528)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 4, with quarterly update 3, or later, SUSE Linux Enterprise Server 9 for POWER with service pack 3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#7529) - Quantity 150 of #1298

(No Longer Available as of August 28, 2009)

Ships a quantity of 150 #1298 146.8GB disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records.

  • Attributes provided: Quantity of 150 #1298 146.8GB disk units
  • Attributes required: See feature #1298
  • For 9405-520: (#7529)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 4, with quarterly update 3, or later, SUSE Linux Enterprise Server 9 for POWER with service pack 3, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#7538) - Quantity 150 of #3658

(No Longer Available as of February 8, 2013)

Ships a quantity of 150 #3658 425.6GB disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records.

  • Attributes provided: Quantity of 150 #3658 425.6GB disk units
  • For 9405-520: (#7538)
    • Minimum required: 0
    • (Initial order maximum: 0)
    • OS level required: IBM i 5.4 with V5R4M5 SLIC, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#7680) - Accelerator for System i5

(No Longer Available as of April 25, 2014)

Provides additional processing capability for the model 520 with Express Configuration Feature #7140.

  • Attributes provided: Additional processing capability
  • Attributes required: Model 520
  • For 9405-520: (#7680)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: I5/OS V5R3 with V5R3M5 Machine Code, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#7681) - Accelerator for System i5

(No Longer Available as of April 25, 2014)

Provides additional processing capability for the model 520 with Express Configuration Feature #7141.

  • Attributes provided: Additional processing capability
  • Attributes required: Model 520
  • For 9405-520: (#7681)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: I5/OS V5R3 with V5R3M5 Machine Code, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#7682) - Accelerator for System i5

(No Longer Available as of April 25, 2014)

Provides additional processing capability for the model 520 with Express Configuration Feature #7142.

  • Attributes provided: Additional processing capability
  • Attributes required: Model 520
  • For 9405-520: (#7682)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: I5/OS V5R3 with V5R3M5 Machine Code, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#7687) - Accelerator for System i5

(No Longer Available as of November 27, 2009)

Provides additional processing capability for the model 520 with Express Configuration Feature #7148.

  • Attributes provided: Additional processing capability
  • Attributes required: Model 520
  • For 9405-520: (#7687)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: I5/OS V5R3 with V5R3M5 Machine Code, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#7750) - Easy-Access Front Cover

(No longer available as of December 01, 2007)

  • For 9405-520: (#7750)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#7753) - Acoustic Front Door

(No longer available as of May 08, 2007)

Provides an acoustic front door for the deskside system unit.

  • Attributes provided: Acoustic Front Door
  • Attributes required: Deskside Feature (#7885)
  • For 9405-520: (#7753)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#7780) - 2.0m Rack Side Attach Kit

(No Longer Available as of February 8, 2013)

This feature allows a row of racks without side panels to be bolted together in a continuous suite, using the provided side-to-side rack connecting hardware. When multiple racks are joined in this way, cables can be easily run between racks without exiting the continuous rack enclosure. A small gap is maintained between the two adjacent racks, which is filled by three matching steel trim pieces that snap into place on the front, top, and rear, between each rack. The trim pieces cover the space between each rack for an enhanced appearance and for additional protection of the equipment inside the racks. Side panels are needed only for the two end racks of the suite.

  • Attributes provided: Hardware and trim to attach two racks
  • Attributes required: #0553 rack
  • For 9405-520: (#7780)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#7801) - 6m HMC Attachment Cable

(No Longer Available as of October 2, 2009)

The #7801 provides a 6 meter ethernet cable for attachment to a Hardware Management Console (HMC).

  • Attributes provided: Ethernet attachment cable
  • Attributes required: Hardware Management Console
  • For 9405-520: (#7801)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#7802) - 15m HMC Attachment Cable

The #7801 provides a 15 meter ethernet cable for attachment to a Hardware Management Console (HMC).

  • Attributes provided: Ethernet attachment cable
  • Attributes required: Hardware Management Console
  • For 9405-520: (#7802)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#7840) - Side-by-Side for 1.8m Racks

This feature allows a row of racks without side panels to be bolted together in a continuous suite, using the provided side to side rack connecting hardware. When multiple racks are joined in this way, cables can be easily run between racks without having to exit the continuous rack enclosure. A small gap is maintained between the two adjacent racks, which is filled by three matching steel trim pieces that snap into place on the front, top, and rear, between each rack. The trim pieces cover the space between each rack for an enhanced appearance and for additional protection of the equipment inside the racks. Side panels are needed only for the two end racks of the suite.

  • Attributes provided: Hardware and trim to attach two racks
  • Attributes required: #0551 rack
  • For 9405-520: (#7840)
    • Minimum required: 0
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#7841) - Ruggedize Rack Kit

For enhanced rigidity and stability of the rack, the optional Ruggedized Rack Kit provides additional hardware that reinforces the rack and anchors it to the floor. This hardware is designed primarily for use in locations where earthquakes are a concern. The feature includes a large steel brace or truss that bolts into the rear of the rack. It is hinged on the left side so it can swing out of the way for easy access to the rack drawers when necessary. The Ruggedize Rack Kit also includes hardware for bolting the rack to a concrete floor or a similar surface, and bolt-in steel filler panels for any noccupied spaces in the rack.

  • Attributes provided: Rear brace, bolt down hardware, bolt in front filler panels
  • Attributes required: #0551 19-inch 1.8m Rack or #0553 19-inch 2.0M Rack
  • For 9405-520: (#7841)
    • Minimum required: 0
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#7862) - Blind Swap Cassette (Long)

(No longer available as of December 02, 2008)

The #7862 is a standard length, type 3, blind-swap cassette that provides containment of a single, long PCI-X card and supports blind-swap and hot-plugging.

  • Attributes provided: Containment of a single, standard length PCI-X card for placement into a PCI-X slot.
  • Attributes required: 1 empty PCI-X slot
  • For 9405-520: (#7862)
    • Minimum required: 0
    • (Initial order maximum: 0)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#7863) - Blind Swap Cassette (Double)

The #7863 is a standard length, type 3, double-wide, blind-swap cassette that provides containment of a single, double-wide PCI-X card and supports blind-swap and hot-plugging.

  • Attributes provided: Containment of a single, standard length PCI-X card for placement into a PCI-X slot.
  • Attributes required: Two empty PCI-X slots.
  • For 9405-520: (#7863)
    • Minimum required: 0
    • Maximum allowed: 18 (Initial order maximum: 0)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#7883) - Model 520 OEM Rack Mount

(No longer available as of June 01, 2006)

The #7883 provides the necessary hardware to mount a system unit in an OEM rack.

System orders containing #7883 are integrated into an OEM rack at the customer location.

  • Attributes provided: Ability to mount a system unit in an OEM rack.
  • Attributes required: OEM rack
  • For 9405-520: (#7883)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#7884) - 520 Rack Mount

(No longer available as of February 06, 2007)

Indicates this is a rack-mounted system unit. System will ship with IBM mounting rails for installation in an IBM rack.

  • For 9405-520: (#7884)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

    This feature is only orderable as part of a feature conversion as an MES to an existing 9405-520 system.

(#7885) - Deskside

(No longer available as of January 01, 2009)

Indicates this is a deskside system.

  • For 9405-520: (#7885)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#7940) - Adv Power Virtualization

Provides both Virtual I/O Server and Partition Load Manager capability. The Virtual I/O Server is a special-purpose partition that provides virtual I/O resources to AIX 5L and Linux client partitions. The Virtual I/O Server owns the resources that are shared with clients. A physical adapter assigned to a partition can be shared by one or more other partitions, enabling administrators to minimize the number of physical adapters they require for individual clients. The Virtual I/O Server helps reduce costs by eliminating the need for dedicated network adapters, disk adapters, and disk drives.

The Partition Load Manager (PLM) provides automated processor and memory distribution between dynamic LPARs and Micro-Partition-cabable LPARs running the AIX 5L operating system. The PLM application is based on a client/server model for the sharing of system information, such as processor or memory events, across concurrent present LPARs.

Each feature ordered provides one processor authorization. One processor authorization is required for each processors worth of workload used across all partitions utilizing Advanced POWER Virtualization.

  • Attributes provided: Virtual I/O Server and Partition Load Manager capability
  • Attributes required: None
  • For 9405-520: (#7940)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: For i5/OS V6R1,or later, no other operating system needs to be loaded/present. For i5/OS V5R4 with V5R4M5 machine code or ealier, system must also have one of the following operating systems loaded, AIX 5L for POWER V5.3 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later.
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#8131) - 15-Ft Cluster Box Cable

(No longer available as of June 23, 2006)

This cable provides attachment between the 128-port Asynchronous Controller and the first RAN in a daisy chain, or attachment between RANs in the daisy chain.

  • Attributes provided: Links 128-port Async Controller to RAN or RAN-to-RAN
  • Attributes required: (1) 128-port Async Controller or RAN-to-RAN connection in a daisy chain.
  • For 9405-520: (#8131)
    • Minimum required: 0
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#8132) - 9-Inch Cluster Box Cable

(No longer available as of June 23, 2006)

This cable may be substituted for the 4.5 meter (15 foot) async controller cable whenever a customer configuration requires stacked Remote Async Nodes.

  • Attributes provided: Links 128-port Async Controller to RAN or RAN-to-RAN
  • Attributes required: (1) 128-port Async Controller or RAN-to-RAN connection in a daisy chain.
  • For 9405-520: (#8132)
    • Minimum required: 0
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#8133) - RJ45 to DB25 Interposer

(No Longer Available as of November 26, 2010)

This cable can be used to attach EIA-232 devices to the 16 port EIA 232 Remote Async Node (FC 8130 or FC 8134) for the 128-Port Async subsystem. This cable provides a 25-pin D shell connector for device attachment. Four cables are provided per each order.

  • Attributes provided: 4 DB-25 EIA-232 ports
  • Attributes required: 4 RJ-45 ports from a RAN (8130, 8134, 8136)
  • For 9405-520: (#8133)
    • Minimum required: 0
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#8136) - Remote ASYNC Node (Rack)

(No longer available as of June 01, 2006)

The Rack Mountable Remote Asynchronous Node 16-Port EIA-232 (RAN) is a modified version of 16-port Remote Async Node (#8130 and #8134) in an industry-standard 19-inch rack mount chassis to allow simpler installation and ease-of-use. It can also be configured as a desktop device.

As an additional benefit, the metal chassis meets FCC Class B/ CISPR B when used with similarly rated server host to meet the needs of customers with these requirements.

The RAN provides 16 ports of EIA-232 capability with full modem controls on each port and are connected to the 128-port Async Controller (Micro Channel or ISA versions) residing in the host. RANs are connected in daisy-chain fashion up to 8 RANs per 128-port Async Controller.

The rack-mountable RAN offers these enhanced features:

  • Industry-standard 19-inch rack mountable chassis (can be configured for stacking on a desktop or mounted in a 19-inch rack).
  • Meets FCC Class B/CISPR B when used with similarly rated iseries host.
  • All RJ-45 connectors are now on the front panel, greatly enhancing cable management.
  • The DB-15 synchronous connectors (cabling from host to RAN and between RANs) and the power cord and switch are located on the rear panel.
  • Power supply is self contained within the unit.

The rack-mountable RAN offers these same features as the existing RAN product:

  • Identical function and support as existing 16-port Remote Async Node (RAN), feature #8130 or 8134.

  • Operation of 16 to 128 ports by supporting up to 8 RANs (4 per synchronous line) with either a Micro Channel or ISA host adapter.

  • Ability to monitor individual port operation, synchronous line station, and other diagnostics from front panel.

  • Built-in diagnostics can test ports independent of RS/6000 host.

  • Full modem control supports the following interface signals: TxD, RxD, RTS, CTS, DSR, DCD, DTR, RI.

  • The same RJ-45 to DB-25 Converter Cable (feature #8133 -- quantity four per order) currently used on the existing RANs can be used to attach devices having a DB-25 connector to the Remote Async Nodes.

  • Individual ports support a maximum EIA-232 distance of 62 meters (200 feet).

  • Use of the same cabling from host to RAN and RAN to RAN: feature #8131 (4.5 meter), feature #8132 (23 cm) or customer-supplied cables.

  • Location of RAN up to 330 meters from the host using standard shielded 8-wire twisted pair cabling.

  • Remote operation via synchronous modems or CSU/DSU extends the distance and allows location of RANs at geographically distant location from the host.
  • Attributes provided: 16 RJ-45 EIA-232 ports AND 1 RAN-to-RAN connection
  • Attributes required: 1 RAN-to-128-port Controller connection OR 1 RAN-to-RAN connection
  • For 9405-520: (#8136)
    • Minimum required: 0
    • Maximum allowed: 34 (Initial order maximum: 34)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#8137) - Remote ASYNC Node

(No longer available as of June 01, 2006)

#8137 provides remote connection of up to 16 EIA-232 devices to a 128-Port Asynchronous Controller.

Each port can be individually programmed to provide a asynchronous connection of 230 Kbaud, but a limited number of ports in a maximum configuration (128 ports) can be supported at this baud rate.

  • Operation of 16 to 128 ports by supporting up to 8 RANs (4 per synchronous line) with either a Micro Channel, ISA or PCI host adapter.
  • Ability to monitor individual port operation, synchronous line station, and other diagnostics from front panel.
  • Built-in diagnostics can test ports independent of RS/6000 host.
  • Full modem control supports the following interface signals: TxD, RxD, RTS, CTS, DSR, DCD, DTR, RI.
  • The same RJ-45 to DB-25 Converter Cable (feature #8133 -- quantity four per order) currently used on the existing RANs can be used to attach devices having a DB-25 connector to the Remote Async Nodes.
  • Individual ports support a maximum EIA-232 distance of up to 31 meters (100 feet), depending on the baud rate.
  • Use of the same cabling from host to RAN and RAN to RAN: feature #8131 (4.5 meter), feature #8132 (23 cm) or customer supplied cables.
  • Location of RAN up to 330 meters (sync data rate set at 1.2 Mbps) from host using standard shielded 8-wire twisted pair cabling.
  • Remote operation via synchronous modems or CSU/DSU extends the distance and allows location of RANs at geographically distant location from the host.
  • Attributes provided: 16 EIA-232 Async ports
  • Attributes required: One 128-port adapter per eight (#8137s)
  • For 9405-520: (#8137)
    • Minimum required: 0
    • Maximum allowed: 34 (Initial order maximum: 34)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#8244) - PCI WS Audio Adapter

(No longer available as of June 01, 2006)

The Audio PCI Adapter for Workstations is a high performance workstation class audio PCI adapter that is optimized for support in the AIX professional workstation environment and their associated applications. It is 3.3 volt, 32 bit PCI adapter that runs at 33MHz speed and complies with the Intel AC 1997 Version 2.1 Specifications. The Audio PCI Adapter for Workstations provides external jacks for headphones, speaker output, line input, and microphone input as well as an internal connector for CD or DVD drive audio input.

  • Attributes provided: One Audio PCI Adapter with internal and external audio connectors
  • Attributes required: One available PCI slot
  • For 9405-520: (#8244)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#8325) - 520 1.9GHz Processor

(No longer available as of July 08, 2008)

#8325 is a base model 520 system planar that contains a 1-way POWER5+ processor and has no L3 cache. It includes 8 memory DIMM slots and a minimum of one memory feature (one pair of DDR2 DIMMs) is required.

  • Attributes provided: 1-way POWER5+ processor
  • Attributes required: Model 520 system
  • For 9405-520: (#8325)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3 with V5R3M5 Machine Code, or later, AIX 5L for Power V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 4, or later, SUSE Linux Enterprise Server 9 for POWER or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: N/A

(#8327) - 1.9GHz Processor

(No longer available as of January 01, 2009)

#8327 is a base system planar that contains a 1-way POWER5+ processor with 36MB of L3 cache. It includes eight memory DIMM slots and a minimum of one memory feature (one pair of DDR2 DIMMs) is required.

  • Attributes provided: 1-way POWER5+ processor
  • For 9405-520: (#8327)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3 with V5R3M5 Machine Code, or later, AIX 5L for Power V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 4, or later, SUSE Linux Enterprise Server 9 for POWER or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: No

(#8546) - Opt Base 1GB Server Memory

(No longer available as of August 26, 2008)

1 GB DDR memory for an Integrated xSeries Server.

#8546 must be installed in pairs.

  • Attributes provided: 1GB memory for Integrated xSeries Server
  • Attributes required: One memory slot on Integrated xSeries Server
  • For 9405-520: (#8546)
    • Minimum required: 0
    • Maximum allowed: 36 (Initial order maximum: 36)
    • OS level required: i5OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#8800) - USB Keyboard-US English

(No longer available as of May 08, 2007)

This feature provides a USB attached U.S. English #103P keyboard.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#8800)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#8801) - USB Keyboard-French

(No longer available as of May 08, 2007)

This feature provides a USB attached French #189 keyboard.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#8801)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#8802) - USB Keyboard-Italian

(No longer available as of May 08, 2007)

This feature provides a USB attached Italian #142 keyboard.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#8802)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#8803) - USB Keyboard-German/Austrian

(No longer available as of May 08, 2007)

This feature provides a USB attached German/Austrian #129 keyboard.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#8803)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#8804) - USB Keyboard-UK English

(No longer available as of May 08, 2007)

This feature provides a USB attached U.K. English #166 keyboard.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#8804)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#8805) - USB Keyboard-Spanish

(No longer available as of May 08, 2007)

This feature provides a USB attached Spanish #172 keyboard.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#8805)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#8806) - USB Keybd-Japanese

(No longer available as of May 08, 2007)

This feature provides a USB attached Japanese #194 keyboard.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#8806)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#8807) - USB Keybd-Brazil/Portuguese

(No longer available as of May 08, 2007)

This feature provides a USB attached Brazilian Portuguese #275 keyboard.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#8807)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#8808) - USB Keyboard-Canadian/French

(No longer available as of May 08, 2007)

This feature provides a USB attached Canadian French #058 keyboard.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#8808)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#8810) - USB Keyboard-Belgium/Dutch

(No longer available as of May 08, 2007)

This feature provides a USB attached Belgian/Dutch #120 keyboard.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#8810)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#8811) - USB Keyboard-Swedish/Finnish

(No longer available as of May 08, 2007)

This feature provides a USB attached Swedish/Finnish #153 keyboard.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#8811)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#8812) - USB Keyboard-Danish

(No longer available as of May 08, 2007)

This feature provides a USB attached Danish #159 keyboard.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#8812)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#8814) - USB Keyboard-Swiss/Fr/German

(No longer available as of May 08, 2007)

This feature provides a USB attached Swiss/French/German #150F/G keyboard.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#8814)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#8816) - USB Keyboard-Norwegian

(No longer available as of May 08, 2007)

This feature provides a USB attached Norwegian #155 keyboard.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#8816)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#8819) - USB Keybd-Greek

(No longer available as of May 08, 2007)

This feature provides a USB attached Greek #319 keyboard.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#8819)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#8820) - USB Keybd-Hebrew

(No longer available as of May 08, 2007)

This feature provides a USB attached Hebrew #212 keyboard.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#8820)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#8821) - USB Keybd-Hungarian

(No longer available as of May 08, 2007)

This feature provides a USB attached Hungarian #208 keyboard.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#8821)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#8823) - USB Keybd-Polish

(No longer available as of May 08, 2007)

This feature provides a USB attached Polish #214 keyboard.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#8823)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#8825) - USB Keybd-Slovakian

(No longer available as of May 08, 2007)

This feature provides a USB attached Slovakian #245 keyboard.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#8825)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#8826) - USB Keybd-Czech

(No longer available as of May 08, 2007)

This feature provides a USB attached Czeck #243 keyboard.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#8826)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#8827) - USB Keybd-Turkish

(No longer available as of May 08, 2007)

This feature provides a USB attached Turkish #179 keyboard.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#8827)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#8829) - USB Keyboard-LA Spanish

(No longer available as of May 08, 2007)

This feature provides a USB attached Latin America Spanish #171 keyboard.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#8829)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#8830) - USB Keybd-Arabic

(No longer available as of May 08, 2007)

This feature provides a USB attached Arabic #253 keyboard.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#8830)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#8833) - USB Keybd-Korean

(No longer available as of May 08, 2007)

This feature provides a USB attached Korean #413 keyboard.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#8833)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#8834) - USB Keybd-Chinese/US

(No longer available as of May 08, 2007)

This feature provides a USB attached Chinese/US #467 keyboard.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#8834)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#8835) - USB Keybd-French/Canadian

(No longer available as of May 08, 2007)

This feature provides a USB attached French Canadian #445 keyboard.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#8835)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#8836) - USB Keybd-Thailand

(No longer available as of May 08, 2007)

This feature provides a USB attached Thai #191 keyboard.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#8836)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#8838) - USB Keybd-Russian

(No longer available as of May 08, 2007)

This feature provides a USB attached Russian #443 keyboard.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#8838)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#8839) - USB Keybd-Yugoslavian/Latin

(No longer available as of May 08, 2007)

This feature provides a USB attached Yugoslavian/Latin #105 keyboard.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#8839)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#8840) - USB Keybd-US English

(No longer available as of May 08, 2007)

This feature provides a USB attached US English #103P (EMEA) keyboard.

  • Attributes provided: Keyboard
  • Attributes required: USB Port
  • For 9405-520: (#8840)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#8841) - USB Mouse and Keybd Cable

(No Longer Available as of December 31, 2009)

A three-button mouse and cable for attachment to a keyboard.

  • Attributes provided: Three-button mouse
  • Attributes required: Keyboard with mouse attachment port
  • For 9405-520: (#8841)
    • Minimum required: 0
    • Maximum allowed: No Max (Initial order maximum: 250)
    • OS level required: AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE LINUX Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#8950) - 520 1.5GHz Processor

(No longer available as of June 01, 2006)

#8950 is a base system planar which contains a 1-way single chip POWER5 processor.

  • For 9405-520: (#8950)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: N/A

(#8951) - 520 1.5GHz Processor

(No longer available as of July 08, 2008)

#8951 is a base system planar which contains a 1-way single chip POWER5 processor.

  • For 9405-520: (#8951)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: AIX ?.?
    • Initial Order/MES/Both/Supported: Supported
    • CSU: No

(#8972) - 520 1.5GHz Processor

(No longer available as of July 08, 2008)

Provides a base model 520 system planar which contains a 1.5Ghz 1-way single chip POWER5 processor.

  • For 9405-520: (#8972)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: N/A

(#9004) - Southern Hemisphere Display

Specifies that southern hemisphere models are required for all CRT monitors on the initial plant order or on MES orders. Not required with TFT monitors.

  • Attributes provided: None
  • Attributes required: Monitor
  • For 9405-520: (#9004)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#9493) - Base PCI WAN for ECS

(No Longer Available as of August 28, 2009)

The #9493 is a WAN with modem adapter that provides connectivity for IBM Electronic Customer Support (ECS) only. This feature is the non-Complex Impedance Matching (CIM) version offered in all countries except Australia and New Zealand. #9493 is functionally equivalent to #0614, #2793, and #9793, but #9493 indicates to IBM configurator tools that the IOA is being used by i5/OS in an IOP-less mode. When in IOP-less mode, the adapter function is restricted to communicating to IBM ECS on port 0 (modem port). Port 1 is the RVX port and is not supported in an IOP-less mode.

Port 0 supports V.92 56K PPP, V.92 data modem, and V.44 data compression. Port 0 does not provide synchronous modem capabilities (SDLC and synchronous PPP).

Select one of the following cables to attach to port 0 (modem port):

  • #1010 Modem Cable - Austria
  • #1011 Modem Cable - Belgium
  • #1012 Modem Cable - Africa
  • #1013 Modem Cable - Israel
  • #1014 Modem Cable - Italy
  • #1015 Modem Cable - France
  • #1016 Modem Cable - Germany
  • #1017 Modem Cable - U.K.
  • #1018 Modem Cable - Iceland/Sweden
  • #1020 Modem Cable - Hong Kong/New Zealand
  • #1021 Modem Cable - Finland/Norway
  • #1022 Modem Cable - Netherlands
  • #1023 Modem Cable - Switzerland
  • #1024 Modem Cable - Denmark
  • #1025 Modem Cable - U.S./Canada

The #9493 does not support the remote ring indicate function. This feature has country-specific usage.

#6833/#9933 are physically the same card as the #6803/#9493, but with i5/OS V5R4 with V5R4M5 machine code additional function is provided including the use of the 2nd communication port and a separate feature code is used to denote this.

  • Attributes provided: One integrated modem port for communication with IBM ECS
  • Attributes required: One PCI slot (3 volt)
  • For 9405-520: (#9493)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3 with V5R3M5 Machine Code, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#9509) - Base Ultra320 SCSI RAID Cntr

(No longer available as of June 01, 2006)

#9509 is a SCSI RAID controller which is installed into its own specific internal slot of a system unit and does not require a PCI slot. It functionally replaces the base integrated disk controller, adding RAID functionality and 16MB disk controller cache.

A minimum of three disk units is required for a RAID disk array.

  • Attributes provided: RAID Data Protection for system unit DASD
  • Attributes required: Unused RAID controller slot in a system unit.
  • For 9405-520: (#9509)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: N/A

(#9510) - Base Integrated Cache - 40MB

(No longer available as of January 01, 2009)

Provides a card that augments the base integrated disk controller with 40MB of write cache and enables RAID-5 capability for the internal disk drives of the system unit. #9510 is installed into its own specific internal slot of a system unit and does not require a PCI slot. The #9510 is physically equivalent to the #5727.

A minimum of three disk units are required for a RAID-5 disk array.

  • Attributes provided: 40 MB write cache and RAID-5 data protection for system unit disk drives
  • Attributes required: Unused write cache/RAID controller slot in a system unit.
  • For 9405-520: (#9510)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later, AIX 5L for POWER V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 4, or later, SUSE Linux Enterprise Server 9 for POWER, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: N/A

(#9517) - Base HSL-2/RIO-G Bus Adapter

(No Longer Available as of August 28, 2009)

The 9517, which provides two HSL-2/RIO-G ports, can be selected as base with a new order #0595, #5094, #5095, #5294 or #8294.

Migration of existing #9517s to IBM eServer i5 servers is allowed. Existing #9517s would be installed in migrating expansion unit/ towers (#0595, #5094, #5095 and #5294).

  • Attributes provided: HSL-2RIO-G connectivity
  • Attributes required: HSL slot in expansion unit/tower
  • For 9405-520: (#9517)
    • Minimum required: 0
    • Maximum allowed: 12 (Initial order maximum: 12)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#9526) - Base 35.16GB 15k rpm Disk Dr

(No longer available as of May 08, 2007)

#9526 is a 15k rpm disk unit with 35.16GB capacity and a SCSI interface. #9526 is physically equivalent to a #4326 disk drive.

  • Attributes provided: 35.16GB disk unit
  • Attributes required: Disk unit slot and a disk unit controller
  • For 9405-520: (#9526)
    • Minimum required: 0
    • Maximum allowed: 4 (Initial order maximum: 4)
    • OS level required: i5OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: N/A

(#9531) - Base HSL-2 Bus Adapter

(No Longer Available as of July 30, 2010)

#9531 provides two HSL-2 ports and is included as base on the #5790 PCI Expansion Drawer.

  • Attributes provided: Two HSL-2 Ports
  • Attributes required: #5790 PCI Expansion Drawer
  • For 9405-520: (#9531)
    • Minimum required: 0
    • Maximum allowed: 6 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later, AIX 5L for Power V5.2 for IBM eServer, or later, Red Hat Enterprise Linux AS for POWER Version 3, or later, SUSE Linux Enterprise Server 9 for POWER or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#9540) - Base DVD-ROM

(No longer available as of January 01, 2009)

The 8X/24X(max) Slimline IDE DVD-ROM Drive is an internal tray loading DVD-ROM drive providing up to 3600KB/sec (CD-ROM) and 10.3MB/ sec (DVD-ROM) data transfer rates. DVD video is not supported.

Characteristics:

  • Media Data Transfer Rate: CD-ROM=3600 KB/sec (max), DVD-ROM=10.3MB/sec (max)
  • Interface: IDE/ATAPI
  • Avg. Random Access Time: CD-ROM=95ms(typical), DVD-ROM=150ms (typical)
  • Buffer Memory: 256KB
  • Media capacity: CD-ROM=650MB, DVD-ROM= 4.7 GB(single sided)/9.4 GB(double-sided)
  • Multisession capable (Reads CD/R & CD-R/W media)
  • 12.7mm Slimline form factor
  • Operates in either vertical or horizontal positions
  • Interface supports standard and extended XA formats
  • Loading tray supports 12cm and 8cm disks
  • Attributes provided: 8X/24X(max) IDE DVD-ROM Drive
  • Attributes required: One Slimline media bay
  • For 9405-520: (#9540)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: N/A

(#9544) - Base 1GB Main Storage

(No longer available as of February 06, 2007)

#9544 consists of four 256MB DIMMs for a total of 1GB.

  • Attributes provided: 1GB of main storage
  • Attributes required: 4 DIMM slots
  • For 9405-520: (#9544)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: N/A

(#9545) - Base 4GB DDR-1 Main Storage

(No longer available as of February 06, 2007)

Provides four 1GB DIMMs for a total of 4GB of main storage.

  • Attributes provided: 4GB of main storage
  • Attributes required: #7395 or #7396 Express Edition
  • For 9405-520: (#9545)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: N/A

    Required on 9405/520 systems with #7395 and #7396 Express Editions.

(#9547) - Base 2GB Main Storage

(No longer available as of February 06, 2007)

#9547 consists of four 512MB DIMMs for a total of 2GB.

  • Attributes provided: 2GB main storage
  • Attributes required: 4 DIMM slots
  • For 9405-520: (#9547)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: N/A

(#9548) - Base 1GB Main Storage

(No longer available as of January 01, 2009)

Provides 1GB of zero-priced main storage. #9548 consists of two 512MB DDR2 DIMMs.

  • Attributes provided: 1GB of main storage
  • Attributes required: 2 DDR2 DIMM slots
  • For 9405-520: (#9548)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3 with V5R3M5 Machine Code, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: N/A

(#9549) - Base 2GB Main Storage

(No longer available as of January 01, 2009)

Provides 2GB of zero-priced main storage. #9549 consists of two 1GB DDR2 DIMMs.

  • Attributes provided: 2GB of main storage
  • Attributes required: 2 DDR2 DIMM slots
  • For 9405-520: (#9549)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3 with V5R3M5 Machine Code, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: N/A

(#9553) - Base 4GB Main Storage

(No longer available as of July 08, 2008)

Provides 4GB of zero-priced main storage. #9553 consists of two 2GB DDR2 DIMMs.

  • Attributes provided: 4GB of main storage
  • Attributes required: 2 DDR2 DIMM slots
  • For 9405-520: (#9553)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3 with V5R3M5 Machine Code, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: N/A

(#9613) - Base 70GB 15k rpm Disk Unit

(No longer available as of January 01, 2009)

#9613 is a base 15k rpm disk unit with 70.56GB capacity and an Ultra320 SCSI interface. #9613 is physically equivalent to a #4327 disk drive.

  • Attributes provided: 70.56GB disk unit
  • Attributes required: disk unit slot and a disk unit controller
  • For 9405-520: (#9613)
    • Minimum required: 0
    • OS level required: i5/OS V5R3 with V5R3M5 Machine Code, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: N/A

(#9653) - Base 30GB 1/4-Inch Cart Tape

(No longer available as of January 01, 2009)

#9653 is a base 30GB 1/4-Inch Cartridge Tape Unit mounted in a removable media device slot of a system unit.

#9653 may be used for save/restore, alternate IPL, program distribution, migration and 1/4-inch cartridge tape exchange.

#9653 will read/write the following tape formats:

  • 30GB (up to 60GB with compression in SLR60 format) with IBM SLR60-30GB Data Cartridge (19P4209)
  • 25GB (up to 50GB with compression in MLR3 format) with IBM MLR3-25GB Data Cartridge (59H4128)
  • 16GB (up to 32GB with compression in QIC5010 format) with IBM MLR1-16GB Data Cartridge (59H4175)
  • 5GB (up to 10GB with compression in SLR100 format) with IBM SLR100-5GB Data Cartridge (35L0661)
  • 2GB (up to 4GB with compression in QIC5010 format) with IBM MLR1-2GB Data Cartridge (35L0589)

#9653 is capable of read only support of the following tape formats:

  • 4GB (QIC4GB format) with SLR5-4GB Data Cartridge (59H3660)
  • 2.5GB (QIC2GB format) with IBM DC9250 Data Cartridge (16G8436)

#9653 has the these technical specifications for the primary recording format:

  • Cartridge Capacity (Native) = 30.0GB (1500-ft tape)
  • Cartridge Capacity (Compression) = 60.0GB (1500-ft tape)
  • Data Rate (Native) = 4.0MB/s
  • Data Rate (Compression) = 8.0MB/s
  • Attributes provided: 30GB 1/4-inch tape device
  • Attributes required: Half-high, autodocking removable media bay and a disk controller in place to interface to this media bay
  • For 9405-520: (#9653)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: N/A

(#9726) - Base 512MB Server Memory

(No longer available as of August 26, 2008)

512 MB DDR memory for an Integrated xSeries Server.

#9726 must be installed in pairs.

  • Attributes provided: 512MB memory for Integrated xSeries Server
  • Attributes required: One memory slot on Integrated xSeries Server
  • For 9405-520: (#9726)
    • Minimum required: 0
    • Maximum allowed: 36 (Initial order maximum: 36)
    • OS level required: i5/OS V5R2 or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#9744) - Base PCI IOP

(No Longer Available as of August 28, 2009)

#9744 is a base PCI I/O processor that drives PCI IOA adapters in the system unit and in HSL attached PCI or PCI-X I/O expansion towers/units.

A #9744 can drive a maximum of four IOAs, subject to configuration restrictions.

One #9744 is the default on each order (but may be removed) when a #4811, #4812, #4813, #9812 or #9813 is on the order.

  • Attributes provided: Ability to drive up to four PCI/PCI-X IOAs
  • Attributes required: One PCI/PCI-X slot
  • For 9405-520: (#9744)
    • Minimum required: 0
    • Maximum allowed: 18 (Initial order maximum: 0)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: MES
    • CSU: Yes

(#9746) - Base PCI Twinax Wrkstn IOA

(No longer available as of July 08, 2008)

The #9746 provides support for up to 40 twinaxial displays and printers. A 20-ft cable with an eight port expansion (breakout) box is included with this adapter. Each expansion port supports seven attached devices, allowing for 56 total attached devices, of which only 40 can be active. This feature is allowed only on initial orders for Model 520 servers or model upgrades into a Model 520.

  • Attributes provided: Attachment of twinaxial devices
  • Attributes required: One PCI slot (3V or 5V)
  • For 9405-520: (#9746)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R2, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: N/A

(#9793) - Base PCI 2-Line WAN w/Modem

(No Longer Available as of August 28, 2009)

#9793 is the base feature code for FC#2793, PCI 2-Line WAN w/ Modem. Please refer to FC#2793 for a description of the capabilities of FC#9793.

  • For 9405-520: (#9793)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R2, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#9844) - Base PCI IOP

(No Longer Available as of August 28, 2009)

#9844 is a base PCI I/O processor that drives PCI IOA adapters in the system unit and in HSL attached PCI or PCI-X I/O expansion towers/units.

A #9844 can drive a maximum of four IOAs, subject to configuration restrictions.

One #9844 is included in the following expansion towers/units:

  • #0595
  • #5094
  • #5095

Two #9844s are included with each #5294.

Note: With the availability of V5R4, #9844 is no longer included with #0595, #5094, #5095 and #5294.

  • Attributes provided: Ability to drive up to four PCI/PCI-X IOAs
  • Attributes required: One PCI/PCI-X slot
  • For 9405-520: (#9844)
    • Minimum required: 0
    • Maximum allowed: 7 (Initial order maximum: 7)
    • OS level required: i5/OS V5R2, or later
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes

(#9877) - Base HSL-2 Bus Adapter

(No longer available as of August 26, 2008)

This feature, which provides two HSL-2 ports, can be selected as base on a new order #0588 or #5088.

Migration of existing #9877s to system i5 servers is allowed. Existing #9877s would be installed in migrating expansion towers/ units (#5074, #5079, #5094, #5294, #0595, #5095).

  • Attributes provided: Two HSL-2 ports
  • Attributes required: Expansion unit/tower HSL slot
  • For 9405-520: (#9877)
    • Minimum required: 0
    • Maximum allowed: 6 (Initial order maximum: 6)
    • OS level required: i5/OS V5R3, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

(#9933) - PCI 2-Line WAN w/Modem NoIOP

The #9933 is a 2-line/port WAN w/modem adapter. This feature is the non-CIM (Complex Impedance Matching) version offered in all countries except Australia and New Zealand.

#6833/#9933 are physically the same card as #0614/#2793/#9793, but #6833/#9933 indicates to IBM configurator tools that the IOA is being used by i5/OS in an IOP-less mode. #6833/#9933 are physically the same card as the IOP-less #6803/#9493, but with i5/OS V5R4 with V5R4M5 machine code, additional function is provided, including the use of the second communication port, and a separate feature code is used to denote this.

Port 0 is the modem port and supports V.92 56K Async PPP, V.92 data modem, V.44 data compression, V.34 FAX modem and FAX functions such as ECM and 2D/1D conversion. Port 0 does not provide Sync modem capabilities (SDLC and Sync PPP).

Port 1 is the RVX port and supports multiple communications protocols, including synchronous operations.

Select one of the following cables to attach to port 0(modem port):

  • #1010 Modem Cable - Austria
  • #1011 Modem Cable - Belgium
  • #1012 Modem Cable - Africa
  • #1013 Modem Cable - Israel
  • #1014 Modem Cable - Italy
  • #1015 Modem Cable - France
  • #1016 Modem Cable - Germany
  • #1017 Modem Cable - UK
  • #1018 Modem Cable - Iceland/Sweden
  • #1020 Modem Cable - HK/NZ
  • #1021 Modem Cable - Fin/Nor
  • #1022 Modem Cable - Netherlands
  • #1023 Modem Cable - Swiss
  • #1024 Modem Cable - Denmark
  • #1025 Modem Cable - US/Canada

Select one of the following cables to attach to port 1(RVX port):

  • #0348 - V.24/EIA232 20-Ft PCI Cable
  • #0353 - V.35 20-Ft PCI Cable
  • #0356 - V.36 20-Ft PCI Cable
  • #0359 - X.21 20-Ft PCI Cable
  • #0367 - Operations Console PCI Cable (ships with a 25 pin to 9 pin adapter)
    • Multiple #0367 cables can be ordered but only one per #2793 to serve as consoles for secondary partitions when Logical Partitioning is utilized.

ECS is supported from both the modem port and the RVX port. The following cable is required to support ECS from the RVX port:

  • #0348 - V.24/EIA232 20-Ft PCI Cable

The #9933 does not support the remote ring indicate function.

#9933 does not support SNA communications except through the i5/ OS V5R4 Enterprise Extender function.

  • Attributes provided: One RVX port and one integrated modem port
  • Attributes required: One PCI slot (3 volt)
  • For 9405-520: (#9933)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: i5/OS V5R4 with V5R4M5 Machine Code, or later
    • Initial Order/MES/Both/Supported: Supported
    • CSU: Yes

Feature Conversions

From:                        To:
Type Model Feature           Type Model Feature
Description                  Description                  RP  CM  Chg
---------------------------- ---------------------------- --- --- ---
9405 520   2744              9405 520   0603              No  No  Yes
PCI 100Mbps Token-Ring IOA   Direct Attach-2744
9405 520   2772              9405 520   0609              No  No  Yes
PCI Dual WAN/Modem IOA       Direct Attach-2772
9405 520   2742              9405 520   0613              No  No  Yes
PCI Two-Line WAN IOA         Direct Attach-2742
9405 520   6805              9405 520   0613              No  No  Yes
PCI 2-Line WAN IOA No IOP    Direct Attach-2742
9405 520   2793              9405 520   0614              No  No  Yes
PCI 2-Line WAN w/Modem       Direct Attach-2793
9405 520   6803              9405 520   0614              No  No  Yes
PCI WAN for ECS              Direct Attach-2793
9405 520   6833              9405 520   0614              No  No  Yes
PCI 2-Line WAN w/Modem NoIOP Direct Attach-2793
9405 520   9793              9405 520   0614              No  No  Yes
Base PCI 2-Line WAN w/Modem  Direct Attach-2793
9405 520   2805              9405 520   0616              No  No  Yes
PCI Quad Modem IOA           Direct Attach-2805
9405 520   6808              9405 520   0616              No  No  Yes
PCI 4-Modem WAN IOA No IOP   Direct Attach-2805
9405 520   5700              9405 520   0620              No  No  Yes
PCI 1Gbps Ethernet IOA       Direct Attach-5700
9405 520   6800              9405 520   0620              No  No  Yes
PCI 1Gbps Ethernet IOA       Direct Attach-5700
9405 520   5701              9405 520   0621              No  No  Yes
PCI 1Gbps Ethernet UTP IOA   Direct Attach-5701
9405 520   6801              9405 520   0621              No  No  Yes
PCI 1Gbps Ethernet UTP IOA   Direct Attach-5701
9405 520   2849              9405 520   0623              No  No  Yes
PCI 100/10Mbps Ethernet IOA  Direct Attach-2849
9405 520   5704              9405 520   0625              No  No  Yes
PCI-X Fibre Chan Tape Ctlr   Direct Attach-5704
9405 520   2787              9405 520   0626              No  No  Yes
PCI-X Fibre Chan Disk Ctlr   Direct Attach-2787
9405 520   2780              9405 520   0627              No  No  Yes
PCI-X Ultra4 RAID Disk Ctrl  Direct Attach-2780
9405 520   5703              9405 520   0628              No  No  Yes
PCI-X RAID Disk Unit Ctlr    Direct Attach-5703
9405 520   5761              9405 520   0629              No  No  Yes
PCI-X Fibre Chan Tape Ctlr   4Gbps Fibre Channel (1-Port)
9405 520   5783              9405 520   0630              No  No  Yes
PCI-X iSCSI HBA Copper       PCI-X 1Gbps iSCSI TOE-Copper
9405 520   5784              9405 520   0631              No  No  Yes
PCI-X iSCSI HBA Fiber        PCI-X 1Gbps iSCSI TOE-Optic
9405 520   0627              9405 520   0641              No  No  Yes
Direct Attach-2780           PCI-X Ultra320 SCSI Disk Ctl
9405 520   2780              9405 520   0641              No  No  Yes
PCI-X Ultra4 RAID Disk Ctrl  PCI-X Ultra320 SCSI Disk Ctl
9405 520   5590              9405 520   0641              No  No  Yes
2780 Ctlr w/Aux Write Cache  PCI-X Ultra320 SCSI Disk Ctl
9405 520   5712              9405 520   0645              No  No  Yes
PCI-X Tape Controller        Direct Attach-5712
9405 520   5736              9405 520   0647              No  No  Yes
PCI-X Disk/Tape Ctlr w/IOP   PCI-X Disk/Tape Ctlr No IOP
9405 520   5775              9405 520   0647              No  No  Yes
PCI-X Disk/Tape Ctlr-No IOP  PCI-X Disk/Tape Ctlr No IOP
9405 520   5737              9405 520   0648              No  No  Yes
PCI-X Disk Ctlr-90MB w/IOP   PCI-X Disk Ctlr-90MB No IOP
9405 520   5776              9405 520   0648              No  No  Yes
PCI-X Disk Ctlr-90MB No IOP  PCI-X Disk Ctlr-90MB No IOP
9405 520   5738              9405 520   0649              No  No  Yes
PCI-X Disk Ctlr-1.5GB w/IOP  Direct Attach-5583
9405 520   5777              9405 520   0649              No  No  Yes
PCI-X Disk Ctlr-1.5GB No IOP Direct Attach-5583
9405 520   0651              9405 520   0650              No  No  Yes
Direct Attach-5782           Direct Attach-5778
9405 520   0654              9405 520   0650              No  No  Yes
Direct Attach-5800           Direct Attach-5778
9405 520   5739              9405 520   0650              No  No  Yes
PCI-X EXP24 Ctlr-1.5GB w/IOP Direct Attach-5778
9405 520   5781              9405 520   0650              No  No  Yes
PCI-X EXP24 Ctlr-1.5GB w/IOP Direct Attach-5778
9405 520   5782              9405 520   0650              No  No  Yes
PCI-X EXP24 Ctl-1.5GB No IOP Direct Attach-5778
9405 520   5799              9405 520   0650              No  No  Yes
PCI-X EXP24 Ctlr-1.5GB w/IOP Direct Attach-5778
9405 520   5800              9405 520   0650              No  No  Yes
PCI-X EXP24 Ctl-1.5GB No IOP Direct Attach-5778
9405 520   0650              9405 520   0651              No  No  Yes
Direct Attach-5778           Direct Attach-5782
9405 520   0654              9405 520   0651              No  No  Yes
Direct Attach-5800           Direct Attach-5782
9405 520   5739              9405 520   0651              No  No  Yes
PCI-X EXP24 Ctlr-1.5GB w/IOP Direct Attach-5782
9405 520   5778              9405 520   0651              No  No  Yes
PCI-X EXP24 Ctl-1.5GB No IOP Direct Attach-5782
9405 520   5781              9405 520   0651              No  No  Yes
PCI-X EXP24 Ctlr-1.5GB w/IOP Direct Attach-5782
9405 520   5782              9405 520   0651              No  No  Yes
PCI-X EXP24 Ctl-1.5GB No IOP Direct Attach-5782
9405 520   5799              9405 520   0651              No  No  Yes
PCI-X EXP24 Ctlr-1.5GB w/IOP Direct Attach-5782
9405 520   5800              9405 520   0651              No  No  Yes
PCI-X EXP24 Ctl-1.5GB No IOP Direct Attach-5782
9405 520   0650              9405 520   0654              No  No  Yes
Direct Attach-5778           Direct Attach-5800
9405 520   0651              9405 520   0654              No  No  Yes
Direct Attach-5782           Direct Attach-5800
9405 520   5739              9405 520   0654              No  No  Yes
PCI-X EXP24 Ctlr-1.5GB w/IOP Direct Attach-5800
9405 520   5778              9405 520   0654              No  No  Yes
PCI-X EXP24 Ctl-1.5GB No IOP Direct Attach-5800
9405 520   5781              9405 520   0654              No  No  Yes
PCI-X EXP24 Ctlr-1.5GB w/IOP Direct Attach-5800
9405 520   5782              9405 520   0654              No  No  Yes
PCI-X EXP24 Ctl-1.5GB No IOP Direct Attach-5800
9405 520   5799              9405 520   0654              No  No  Yes
PCI-X EXP24 Ctlr-1.5GB w/IOP Direct Attach-5800
9405 520   5800              9405 520   0654              No  No  Yes
PCI-X EXP24 Ctl-1.5GB No IOP Direct Attach-5800
9405 520   0900              9405 520   0901              Yes Yes Yes
1W Serv Feat 520 1X8950      1W Serv Feat 520 1X8951
9405 520   0900              9405 520   0912              Yes Yes Yes
1W Serv Feat 520 1X8950      1W Serv Feat 520 1x8972
9405 520   0901              9405 520   0912              Yes Yes Yes
1W Serv Feat 520 1X8951      1W Serv Feat 520 1x8972
9405 520   4326              9405 520   1266              No  No  Yes
35.16GB 15k rpm Disk Unit    35.16GB 15k rpm Disk Unit
9405 520   4327              9405 520   1267              No  No  Yes
70.56GB 15k rpm Disk Unit    70.56GB 15k rpm Disk Unit
9405 520   4329              9405 520   1269              No  No  Yes
282.25GB 15k rpm Disk Unit   282.25GB 15k rpm Disk Unit
9405 520   1893              9405 520   1293              No  No  Yes
36.4GB 10k rpm Disk Unit     36.4GB 10k rpm Disk Unit
9405 520   1894              9405 520   1294              No  No  Yes
73.4GB 10k rpm Disk Unit     73.4GB 10k rpm Disk Unit
9405 520   1895              9405 520   1295              No  No  Yes
146.8GB 10k rpm Disk Unit    146.8GB 10k rpm Disk Unit
9405 520   1896              9405 520   1296              No  No  Yes
36.4GB 15k rpm Disk Unit     36.4GB 15k rpm Disk Unit
9405 520   1897              9405 520   1297              No  No  Yes
73.4GB 15k rpm Disk Unit     73.4GB 15k rpm Disk Unit
9405 520   1898              9405 520   1298              No  No  Yes
146.8GB Disk Unit            146.8GB 15k rpm Disk Unit
9405 520   3578              9405 520   1299              No  No  Yes
300GB 10K rpm Disk Unit      300GB 10k rpm Disk Unit
9405 520   1293              9405 520   1893              No  No  Yes
36.4GB 10k rpm Disk Unit     36.4GB 10k rpm Disk Unit
9405 520   1294              9405 520   1894              No  No  Yes
73.4GB 10k rpm Disk Unit     73.4GB 10k rpm Disk Unit
9405 520   1295              9405 520   1895              No  No  Yes
146.8GB 10k rpm Disk Unit    146.8GB 10k rpm Disk Unit
9405 520   1296              9405 520   1896              No  No  Yes
36.4GB 15k rpm Disk Unit     36.4GB 15k rpm Disk Unit
9405 520   1297              9405 520   1897              No  No  Yes
73.4GB 15k rpm Disk Unit     73.4GB 15k rpm Disk Unit
9405 520   1298              9405 520   1898              No  No  Yes
146.8GB 15k rpm Disk Unit    146.8GB Disk Unit
9405 520   0613              9405 520   2742              No  No  Yes
Direct Attach-2742           PCI Two-Line WAN IOA
9405 520   6805              9405 520   2742              No  No  Yes
PCI 2-Line WAN IOA No IOP    PCI Two-Line WAN IOA
9405 520   0603              9405 520   2744              No  No  Yes
Direct Attach-2744           PCI 100Mbps Token-Ring IOA
9405 520   0609              9405 520   2772              No  No  Yes
Direct Attach-2772           PCI Dual WAN/Modem IOA
9405 520   0627              9405 520   2780              No  No  Yes
Direct Attach-2780           PCI-X Ultra4 RAID Disk Ctrl
9405 520   2757              9405 520   2780              Yes No  Yes
PCI-X Ultra RAID Disk Ctrl   PCI-X Ultra4 RAID Disk Ctrl
9405 520   0626              9405 520   2787              No  No  Yes
Direct Attach-2787           PCI-X Fibre Chan Disk Ctlr
9405 520   0614              9405 520   2793              No  No  Yes
Direct Attach-2793           PCI 2-Line WAN w/Modem
9405 520   6803              9405 520   2793              No  No  Yes
PCI WAN for ECS              PCI 2-Line WAN w/Modem
9405 520   9793              9405 520   2793              No  No  Yes
Base PCI 2-Line WAN w/Modem  PCI 2-Line WAN w/Modem
9405 520   0616              9405 520   2805              No  No  Yes
Direct Attach-2805           PCI Quad Modem IOA
9405 520   6808              9405 520   2805              No  No  Yes
PCI 4-Modem WAN IOA No IOP   PCI Quad Modem IOA
9405 520   0623              9405 520   2849              No  No  Yes
Direct Attach-2849           PCI 100/10Mbps Ethernet IOA
9405 520   1299              9405 520   3578              No  No  Yes
300GB 10k rpm Disk Unit      300GB 10K rpm Disk Unit
9405 520   1266              9405 520   4326              No  No  Yes
35.16GB 15k rpm Disk Unit    35.16GB 15k rpm Disk Unit
9405 520   1267              9405 520   4327              No  No  Yes
70.56GB 15k rpm Disk Unit    70.56GB 15k rpm Disk Unit
9405 520   1269              9405 520   4329              No  No  Yes
282.25GB 15k rpm Disk Unit   282.25GB 15k rpm Disk Unit
9405 520   6279              9405 520   4688              No  Yes Yes
160GB VXA-320 Tape Drive     160GB VXA-320 Tape Drive
9405 520   5096              9405 520   5094              No  Yes Yes
PCI-X Exp Tower (no disk)    PCI-X Expansion Tower
9405 520   5296              9405 520   5294              No  Yes Yes
1.8m I/O Tower (no disk)     1.8m I/O Tower
9405 520   2780              9405 520   5580              No  No  Yes
PCI-X Ultra4 RAID Disk Ctrl  2780 Ctlr w/Aux Write Cache
9405 520   5581              9405 520   5580              Yes No  Yes
2757 Ctlr w/Aux Write Cache  2780 Ctlr w/Aux Write Cache
9405 520   2757              9405 520   5581              No  No  Yes
PCI-X Ultra RAID Disk Ctrl   2757 Ctlr w/Aux Write Cache
9405 520   0649              9405 520   5582              No  No  Yes
Direct Attach-5583           5738 Ctlr w/Aux Write Cache
9405 520   2757              9405 520   5582              Yes No  Yes
PCI-X Ultra RAID Disk Ctrl   5738 Ctlr w/Aux Write Cache
9405 520   2780              9405 520   5582              Yes No  Yes
PCI-X Ultra4 RAID Disk Ctrl  5738 Ctlr w/Aux Write Cache
9405 520   5580              9405 520   5582              Yes No  Yes
2780 Ctlr w/Aux Write Cache  5738 Ctlr w/Aux Write Cache
9405 520   5581              9405 520   5582              Yes No  Yes
2757 Ctlr w/Aux Write Cache  5738 Ctlr w/Aux Write Cache
9405 520   5583              9405 520   5582              No  No  Yes
5777 Ctlr w/Aux Write Cache  5738 Ctlr w/Aux Write Cache
9405 520   5590              9405 520   5582              Yes No  Yes
2780 Ctlr w/Aux Write Cache  5738 Ctlr w/Aux Write Cache
9405 520   5591              9405 520   5582              Yes No  Yes
2757 Ctlr w/Aux Write Cache  5738 Ctlr w/Aux Write Cache
9405 520   5738              9405 520   5582              No  No  Yes
PCI-X Disk Ctlr-1.5GB w/IOP  5738 Ctlr w/Aux Write Cache
9405 520   5777              9405 520   5582              No  No  Yes
PCI-X Disk Ctlr-1.5GB No IOP 5738 Ctlr w/Aux Write Cache
9405 520   0649              9405 520   5583              No  No  Yes
Direct Attach-5583           5777 Ctlr w/Aux Write Cache
9405 520   2757              9405 520   5583              Yes No  Yes
PCI-X Ultra RAID Disk Ctrl   5777 Ctlr w/Aux Write Cache
9405 520   2780              9405 520   5583              Yes No  Yes
PCI-X Ultra4 RAID Disk Ctrl  5777 Ctlr w/Aux Write Cache
9405 520   5580              9405 520   5583              Yes No  Yes
2780 Ctlr w/Aux Write Cache  5777 Ctlr w/Aux Write Cache
9405 520   5581              9405 520   5583              Yes No  Yes
2757 Ctlr w/Aux Write Cache  5777 Ctlr w/Aux Write Cache
9405 520   5582              9405 520   5583              No  No  Yes
5738 Ctlr w/Aux Write Cache  5777 Ctlr w/Aux Write Cache
9405 520   5590              9405 520   5583              Yes No  Yes
2780 Ctlr w/Aux Write Cache  5777 Ctlr w/Aux Write Cache
9405 520   5591              9405 520   5583              Yes No  Yes
2757 Ctlr w/Aux Write Cache  5777 Ctlr w/Aux Write Cache
9405 520   5738              9405 520   5583              No  No  Yes
PCI-X Disk Ctlr-1.5GB w/IOP  5777 Ctlr w/Aux Write Cache
9405 520   5777              9405 520   5583              No  No  Yes
PCI-X Disk Ctlr-1.5GB No IOP 5777 Ctlr w/Aux Write Cache
9405 520   0641              9405 520   5590              No  No  Yes
PCI-X Ultra320 SCSI Disk Ctl 2780 Ctlr w/Aux Write Cache
9405 520   2780              9405 520   5590              No  No  Yes
PCI-X Ultra4 RAID Disk Ctrl  2780 Ctlr w/Aux Write Cache
9405 520   2757              9405 520   5591              No  No  Yes
PCI-X Ultra RAID Disk Ctrl   2757 Ctlr w/Aux Write Cache
9405 520   0620              9405 520   5700              No  No  Yes
Direct Attach-5700           PCI 1Gbps Ethernet IOA
9405 520   6800              9405 520   5700              No  No  Yes
PCI 1Gbps Ethernet IOA       PCI 1Gbps Ethernet IOA
9405 520   0621              9405 520   5701              No  No  Yes
Direct Attach-5701           PCI 1Gbps Ethernet UTP IOA
9405 520   6801              9405 520   5701              No  No  Yes
PCI 1Gbps Ethernet UTP IOA   PCI 1Gbps Ethernet UTP IOA
9405 520   0628              9405 520   5703              No  No  Yes
Direct Attach-5703           PCI-X RAID Disk Unit Ctlr
9405 520   0625              9405 520   5704              No  No  Yes
Direct Attach-5704           PCI-X Fibre Chan Tape Ctlr
9405 520   0645              9405 520   5712              No  No  Yes
Direct Attach-5712           PCI-X Tape Controller
9405 520   0647              9405 520   5736              No  No  Yes
PCI-X Disk/Tape Ctlr No IOP  PCI-X Disk/Tape Ctlr w/IOP
9405 520   5775              9405 520   5736              No  No  Yes
PCI-X Disk/Tape Ctlr-No IOP  PCI-X Disk/Tape Ctlr w/IOP
9405 520   0648              9405 520   5737              No  No  Yes
PCI-X Disk Ctlr-90MB No IOP  PCI-X Disk Ctlr-90MB w/IOP
9405 520   5776              9405 520   5737              No  No  Yes
PCI-X Disk Ctlr-90MB No IOP  PCI-X Disk Ctlr-90MB w/IOP
9405 520   2757              9405 520   5738              Yes No  Yes
PCI-X Ultra RAID Disk Ctrl   PCI-X Disk Ctlr-1.5GB w/IOP
9405 520   2780              9405 520   5738              Yes No  Yes
PCI-X Ultra4 RAID Disk Ctrl  PCI-X Disk Ctlr-1.5GB w/IOP
9405 520   5777              9405 520   5738              No  No  Yes
PCI-X Disk Ctlr-1.5GB No IOP PCI-X Disk Ctlr-1.5GB w/IOP
9405 520   0650              9405 520   5739              No  No  Yes
Direct Attach-5778           PCI-X EXP24 Ctlr-1.5GB w/IOP
9405 520   0651              9405 520   5739              No  No  Yes
Direct Attach-5782           PCI-X EXP24 Ctlr-1.5GB w/IOP
9405 520   0654              9405 520   5739              No  No  Yes
Direct Attach-5800           PCI-X EXP24 Ctlr-1.5GB w/IOP
9405 520   5778              9405 520   5739              No  No  Yes
PCI-X EXP24 Ctl-1.5GB No IOP PCI-X EXP24 Ctlr-1.5GB w/IOP
9405 520   5781              9405 520   5739              No  No  Yes
PCI-X EXP24 Ctlr-1.5GB w/IOP PCI-X EXP24 Ctlr-1.5GB w/IOP
9405 520   5782              9405 520   5739              No  No  Yes
PCI-X EXP24 Ctl-1.5GB No IOP PCI-X EXP24 Ctlr-1.5GB w/IOP
9405 520   5799              9405 520   5739              No  No  Yes
PCI-X EXP24 Ctlr-1.5GB w/IOP PCI-X EXP24 Ctlr-1.5GB w/IOP
9405 520   5800              9405 520   5739              No  No  Yes
PCI-X EXP24 Ctl-1.5GB No IOP PCI-X EXP24 Ctlr-1.5GB w/IOP
9405 520   5761              9405 520   5758              No  No  Yes
PCI-X Fibre Chan Tape Ctlr   4Gbps Fibre Channel (1-Port)
9405 520   0629              9405 520   5761              No  No  Yes
4Gbps Fibre Channel (1-Port) PCI-X Fibre Chan Tape Ctlr
9405 520   5758              9405 520   5761              No  No  Yes
4Gbps Fibre Channel (1-Port) PCI-X Fibre Chan Tape Ctlr
9405 520   0647              9405 520   5775              No  No  Yes
PCI-X Disk/Tape Ctlr No IOP  PCI-X Disk/Tape Ctlr-No IOP
9405 520   5736              9405 520   5775              No  No  Yes
PCI-X Disk/Tape Ctlr w/IOP   PCI-X Disk/Tape Ctlr-No IOP
9405 520   0648              9405 520   5776              No  No  Yes
PCI-X Disk Ctlr-90MB No IOP  PCI-X Disk Ctlr-90MB No IOP
9405 520   5737              9405 520   5776              No  No  Yes
PCI-X Disk Ctlr-90MB w/IOP   PCI-X Disk Ctlr-90MB No IOP
9405 520   0649              9405 520   5777              No  No  Yes
Direct Attach-5583           PCI-X Disk Ctlr-1.5GB No IOP
9405 520   2757              9405 520   5777              Yes No  Yes
PCI-X Ultra RAID Disk Ctrl   PCI-X Disk Ctlr-1.5GB No IOP
9405 520   2780              9405 520   5777              Yes No  Yes
PCI-X Ultra4 RAID Disk Ctrl  PCI-X Disk Ctlr-1.5GB No IOP
9405 520   5738              9405 520   5777              No  No  Yes
PCI-X Disk Ctlr-1.5GB w/IOP  PCI-X Disk Ctlr-1.5GB No IOP
9405 520   0650              9405 520   5778              No  No  Yes
Direct Attach-5778           PCI-X EXP24 Ctl-1.5GB No IOP
9405 520   0651              9405 520   5778              No  No  Yes
Direct Attach-5782           PCI-X EXP24 Ctl-1.5GB No IOP
9405 520   0654              9405 520   5778              No  No  Yes
Direct Attach-5800           PCI-X EXP24 Ctl-1.5GB No IOP
9405 520   5739              9405 520   5778              No  No  Yes
PCI-X EXP24 Ctlr-1.5GB w/IOP PCI-X EXP24 Ctl-1.5GB No IOP
9405 520   5781              9405 520   5778              No  No  Yes
PCI-X EXP24 Ctlr-1.5GB w/IOP PCI-X EXP24 Ctl-1.5GB No IOP
9405 520   5782              9405 520   5778              No  No  Yes
PCI-X EXP24 Ctl-1.5GB No IOP PCI-X EXP24 Ctl-1.5GB No IOP
9405 520   5799              9405 520   5778              No  No  Yes
PCI-X EXP24 Ctlr-1.5GB w/IOP PCI-X EXP24 Ctl-1.5GB No IOP
9405 520   5800              9405 520   5778              No  No  Yes
PCI-X EXP24 Ctl-1.5GB No IOP PCI-X EXP24 Ctl-1.5GB No IOP
9405 520   0650              9405 520   5781              No  No  Yes
Direct Attach-5778           PCI-X EXP24 Ctlr-1.5GB w/IOP
9405 520   0651              9405 520   5781              No  No  Yes
Direct Attach-5782           PCI-X EXP24 Ctlr-1.5GB w/IOP
9405 520   0654              9405 520   5781              No  No  Yes
Direct Attach-5800           PCI-X EXP24 Ctlr-1.5GB w/IOP
9405 520   5739              9405 520   5781              No  No  Yes
PCI-X EXP24 Ctlr-1.5GB w/IOP PCI-X EXP24 Ctlr-1.5GB w/IOP
9405 520   5778              9405 520   5781              No  No  Yes
PCI-X EXP24 Ctl-1.5GB No IOP PCI-X EXP24 Ctlr-1.5GB w/IOP
9405 520   5782              9405 520   5781              No  No  Yes
PCI-X EXP24 Ctl-1.5GB No IOP PCI-X EXP24 Ctlr-1.5GB w/IOP
9405 520   5799              9405 520   5781              No  No  Yes
PCI-X EXP24 Ctlr-1.5GB w/IOP PCI-X EXP24 Ctlr-1.5GB w/IOP
9405 520   5800              9405 520   5781              No  No  Yes
PCI-X EXP24 Ctl-1.5GB No IOP PCI-X EXP24 Ctlr-1.5GB w/IOP
9405 520   0650              9405 520   5782              No  No  Yes
Direct Attach-5778           PCI-X EXP24 Ctl-1.5GB No IOP
9405 520   0651              9405 520   5782              No  No  Yes
Direct Attach-5782           PCI-X EXP24 Ctl-1.5GB No IOP
9405 520   0654              9405 520   5782              No  No  Yes
Direct Attach-5800           PCI-X EXP24 Ctl-1.5GB No IOP
9405 520   5739              9405 520   5782              No  No  Yes
PCI-X EXP24 Ctlr-1.5GB w/IOP PCI-X EXP24 Ctl-1.5GB No IOP
9405 520   5778              9405 520   5782              No  No  Yes
PCI-X EXP24 Ctl-1.5GB No IOP PCI-X EXP24 Ctl-1.5GB No IOP
9405 520   5781              9405 520   5782              No  No  Yes
PCI-X EXP24 Ctlr-1.5GB w/IOP PCI-X EXP24 Ctl-1.5GB No IOP
9405 520   5799              9405 520   5782              No  No  Yes
PCI-X EXP24 Ctlr-1.5GB w/IOP PCI-X EXP24 Ctl-1.5GB No IOP
9405 520   5800              9405 520   5782              No  No  Yes
PCI-X EXP24 Ctl-1.5GB No IOP PCI-X EXP24 Ctl-1.5GB No IOP
9405 520   0630              9405 520   5783              No  No  Yes
PCI-X 1Gbps iSCSI TOE-Copper PCI-X iSCSI HBA Copper
9405 520   0631              9405 520   5784              No  No  Yes
PCI-X 1Gbps iSCSI TOE-Optic  PCI-X iSCSI HBA Fiber
9405 520   0650              9405 520   5799              No  No  Yes
Direct Attach-5778           PCI-X EXP24 Ctlr-1.5GB w/IOP
9405 520   0651              9405 520   5799              No  No  Yes
Direct Attach-5782           PCI-X EXP24 Ctlr-1.5GB w/IOP
9405 520   0654              9405 520   5799              No  No  Yes
Direct Attach-5800           PCI-X EXP24 Ctlr-1.5GB w/IOP
9405 520   5739              9405 520   5799              No  No  Yes
PCI-X EXP24 Ctlr-1.5GB w/IOP PCI-X EXP24 Ctlr-1.5GB w/IOP
9405 520   5778              9405 520   5799              No  No  Yes
PCI-X EXP24 Ctl-1.5GB No IOP PCI-X EXP24 Ctlr-1.5GB w/IOP
9405 520   5781              9405 520   5799              No  No  Yes
PCI-X EXP24 Ctlr-1.5GB w/IOP PCI-X EXP24 Ctlr-1.5GB w/IOP
9405 520   5782              9405 520   5799              No  No  Yes
PCI-X EXP24 Ctl-1.5GB No IOP PCI-X EXP24 Ctlr-1.5GB w/IOP
9405 520   5800              9405 520   5799              No  No  Yes
PCI-X EXP24 Ctl-1.5GB No IOP PCI-X EXP24 Ctlr-1.5GB w/IOP
9405 520   0650              9405 520   5800              No  No  Yes
Direct Attach-5778           PCI-X EXP24 Ctl-1.5GB No IOP
9405 520   0651              9405 520   5800              No  No  Yes
Direct Attach-5782           PCI-X EXP24 Ctl-1.5GB No IOP
9405 520   0654              9405 520   5800              No  No  Yes
Direct Attach-5800           PCI-X EXP24 Ctl-1.5GB No IOP
9405 520   5739              9405 520   5800              No  No  Yes
PCI-X EXP24 Ctlr-1.5GB w/IOP PCI-X EXP24 Ctl-1.5GB No IOP
9405 520   5778              9405 520   5800              No  No  Yes
PCI-X EXP24 Ctl-1.5GB No IOP PCI-X EXP24 Ctl-1.5GB No IOP
9405 520   5781              9405 520   5800              No  No  Yes
PCI-X EXP24 Ctlr-1.5GB w/IOP PCI-X EXP24 Ctl-1.5GB No IOP
9405 520   5782              9405 520   5800              No  No  Yes
PCI-X EXP24 Ctl-1.5GB No IOP PCI-X EXP24 Ctl-1.5GB No IOP
9405 520   5799              9405 520   5800              No  No  Yes
PCI-X EXP24 Ctlr-1.5GB w/IOP PCI-X EXP24 Ctl-1.5GB No IOP
9405 520   4688              9405 520   6279              No  Yes Yes
160GB VXA-320 Tape Drive     160GB VXA-320 Tape Drive
9405 520   0620              9405 520   6800              No  No  Yes
Direct Attach-5700           PCI 1Gbps Ethernet IOA
9405 520   5700              9405 520   6800              No  No  Yes
PCI 1Gbps Ethernet IOA       PCI 1Gbps Ethernet IOA
9405 520   0621              9405 520   6801              No  No  Yes
Direct Attach-5701           PCI 1Gbps Ethernet UTP IOA
9405 520   5701              9405 520   6801              No  No  Yes
PCI 1Gbps Ethernet UTP IOA   PCI 1Gbps Ethernet UTP IOA
9405 520   0614              9405 520   6803              No  No  Yes
Direct Attach-2793           PCI WAN for ECS
9405 520   2793              9405 520   6803              No  No  Yes
PCI 2-Line WAN w/Modem       PCI WAN for ECS
9405 520   9793              9405 520   6803              No  No  Yes
Base PCI 2-Line WAN w/Modem  PCI WAN for ECS
9405 520   0613              9405 520   6805              No  No  Yes
Direct Attach-2742           PCI 2-Line WAN IOA No IOP
9405 520   2742              9405 520   6805              No  No  Yes
PCI Two-Line WAN IOA         PCI 2-Line WAN IOA No IOP
9405 520   0616              9405 520   6808              No  No  Yes
Direct Attach-2805           PCI 4-Modem WAN IOA No IOP
9405 520   2805              9405 520   6808              No  No  Yes
PCI Quad Modem IOA           PCI 4-Modem WAN IOA No IOP
9405 520   0614              9405 520   6833              No  No  Yes
Direct Attach-2793           PCI 2-Line WAN w/Modem NoIOP
9405 520   2793              9405 520   6833              No  No  Yes
PCI 2-Line WAN w/Modem       PCI 2-Line WAN w/Modem NoIOP
9405 520   6803              9405 520   6833              No  No  Yes
PCI WAN for ECS              PCI 2-Line WAN w/Modem NoIOP
9405 520   7142              9405 520   7143              Yes No  Yes
520 Express Configuration    520 Express Configuration
9405 520   7140              9405 520   7148              Yes No  Yes
520 Express Configuration    520 Express Configuration
9405 520   7141              9405 520   7148              Yes No  Yes
520 Express Configuration    520 Express Configuration
9405 520   7885              9405 520   7182              No  No  Yes
Deskside                     Rack Mount
9405 520   7311              9405 520   7307              No  No  Yes
Dual I/O Unit Enclosure      Dual I/O Unit Enclosure
9405 520   7682              9405 520   7354              No  No  Yes
Accelerator for System i5    Accelerator for System i5
9405 520   7390              9405 520   7392              Yes No  Yes
Model 520 Express Edition    Model 520 Express Edition
9405 520   7391              9405 520   7392              Yes No  Yes
Model 520 Express Edition    Model 520 Express Edition
9405 520   7393              9405 520   7394              Yes No  Yes
Model 520 Express Edition    Model 520 Express Edition
9405 520   7390              9405 520   7395              Yes No  Yes
Model 520 Express Edition    Model 520 Express Edition
9405 520   7391              9405 520   7395              Yes No  Yes
Model 520 Express Edition    Model 520 Express Edition
9405 520   7392              9405 520   7395              Yes No  Yes
Model 520 Express Edition    Model 520 Express Edition
9405 520   7393              9405 520   7396              Yes No  Yes
Model 520 Express Edition    Model 520 Express Edition
9405 520   7394              9405 520   7396              Yes No  Yes
Model 520 Express Edition    Model 520 Express Edition
9405 520   7680              9405 520   7687              No  No  Yes
Accelerator for System i5    Accelerator for System i5
9405 520   7681              9405 520   7687              No  No  Yes
Accelerator for System i5    Accelerator for System i5
9405 520   7753              9405 520   7750              No  No  Yes
Acoustic Front Door          Easy-Access Front Cover
9405 520   7750              9405 520   7753              No  No  Yes
Easy-Access Front Cover      Acoustic Front Door
9405 520   7885              9405 520   7883              No  No  Yes
Deskside                     Model 520 OEM Rack Mount
9405 520   7885              9405 520   7884              No  No  Yes
Deskside                     520 Rack Mount
9405 520   9793              9405 520   9493              No  No  Yes
Base PCI 2-Line WAN w/Modem  Base PCI WAN for ECS
9405 520   9493              9405 520   9933              No  No  Yes
Base PCI WAN for ECS         PCI 2-Line WAN w/Modem NoIOP
9405 520   9793              9405 520   9933              No  No  Yes
Base PCI 2-Line WAN w/Modem  PCI 2-Line WAN w/Modem NoIOP
 

Codes:

  • RP = Return Parts
  • CM = Continuous Maintenance
  • Chg = Charge

Feature exchanges


Back to topBack to top
 
Accessories

None.

Customer replacement parts

None.
Back to topBack to top
 

Machine elements

None.
Back to topBack to top
 

Supplies

Tape cartridges

  • 30 GB 1/4-inch Cartridge Tape Units

    Data cartridges (write and read):

    • IBM SLR60-37.5 GB (24R0146) 37.5 GB
    • IBM SLR60-30 GB (19P4209) 30 GB
    • IBM SLR100-5 GB (35L0661) 5 GB
    • IBM MLR3-25 GB (59H4128) 25 GB
    • IBM MLR1-16 GB (59H4175) 16 GB
    • IBM MLR1-2 GB (35L0589) 2 GB

    Data cartridges (read):

    • IBM SLR5-4 GB (59H3660) 4 GB
    • IBM DC9250 (16G8436) 2.5 GB

    Test and cleaning cartridges

    • IBM 1/4-inch Cleaning Cartridge (35L0844)
    • IBM Test Cartridge (35L0967)

  • 50 GB 1/4-inch Cartridge Tape Units

    Data cartridges (write and read):

    • IBM SLR100-50 GB (35L0968) 50 GB
    • IBM SLR60-37.5 GB (24R0146) 37.5 GB
    • IBM SLR60-30 GB (19P4209) 30 GB
    • IBM MLR3-25 GB (59H4128) 25 GB
    • IBM SLR100-5 GB (35L0661) 5 GB

    Data cartridges (read):

    • IBM MLR1-16 GB (59H4175) 16 GB
    • IBM SLR5-4 GB (59H3660) 4 GB
    • IBM MLR1-2 GB (35L0589) 2 GB

    Test and cleaning cartridges:

    • IBM 1/4-inch Cleaning Cartridge (35L0844)
    • IBM Test Cartridge (35L0967)

  • 36 GB DAT72 4-mm tape drives

    Data cartridges (write and read):

    • IBM DDS3 Data Cartridge (59H3465) 12GB
    • IBM DDS4 Data Cartridge (59H4456) 20GB
    • IBM DAT72 Data Cartridge (18P7912) 36GB

    Test and cleaning cartridges

    • IBM DAT72 Cleaning Cartridge (21F8763)
    • IBM Test Cartridge (59H4457)

  • 200 GB LTO-2 Tape Units

    Data cartridges (write and read):

    • IBM LTO Ultrium 100 GB Data Cartridge (08L9120)
    • IBM LTO Ultrium 200 GB Data Cartridge (08L9870)

    Test and cleaning cartridges:

    • IBM Universal LTO Cleaning Cartridge (35L2086)
    • IBM LTO Ultrium2 Test Cartridge (24R0395)

  • 80 GB VXA-2 Tape Drives

    Data cartridges (write and read):

    • IBM V6 Data Cartridge (19P4878) 20 GB
    • IBM V17 Data Cartridge (19P4877) 59 GB
    • IBM V23 Data Cartridge (19P4876) 80 GB
    • IBM X6 Data Cartridge (24R2134) 20 GB
    • IBM X10 Data Cartridge (24R2136) 40 GB
    • IBM X23 Data Cartridge (24R2137) 80 GB

    Test and cleaning cartridges:

    • IBM 20 Usage Cleaning Cartridge (19P4880)
    • IBM 80 Usage Cleaning Cartridge (24R2138)
    • IBM V6 Test Cartridge (19P4879)
    • IBM X6 Test Cartridge (24R2135)

  • 160 GB VXA-320 Tape Drives

    Data cartridges (write and read):

    • IBM V23 Data Cartridge (19P4876) 80 GB
    • IBM X6 Data Cartridge (24R2134) 20 GB**
    • IBM X10 Data Cartridge (24R2136) 40 GB**
    • IBM X23 Data Cartridge (24R2137) 80 GB**

    Test and cleaning cartridges:

    • IBM 80 Usage Cleaning Cartridge (24R2138)
    • IBM X6 Test Cartridge (24R2135)

All data cartridge capacities shown are uncompressed. Sales and support

You can get assistance, answers to product-related questions, or arrange for a warranty product replacement - with just one call. To locate your nearest source for ordering IBM Media Products, call the following numbers:

888-IBM-MEDIA (1-888-426-6334)

For additional product information and country-specific phone numbers, visit:

http://www.ibm.com/storage/media

Supplemental media

None.

Trademarks

(R), (TM), * Trademark or registered trademark of International Business Machines Corporation.

Windows is a trademark of Microsoft Corporation.
 © IBM Corporation 2014.