IBM United States
Hardware Announcement 102-054
February 26, 2002
IBM 2074 Model 2 Console Support Controller Consolidating and
Streamlining Console Support Function
ENUS102-054.PDF (51KB)
|
At a Glance
The IBM 2074 Model 2 Console Support Controller:
-
Replaces the console support function of the IBM 3174 Establishment
Controller. One IBM 2074 Model 2 can replace multiple 3174s.
-
Replaces the IBM 2074 Model 1 and increases the number of supported
sessions to 64 per controller.
-
Is shipped with an integrated ESCON adapter with an option for a second
ESCON adapter, both of which connect to a host via a direct ESCON
channel, via an ESCON Director, or with a FICON Bridge.
-
Provides integrated Optical Media Attach (OMA) support, which can be used
to load z/VM distribution tapes (on CD-ROM in OMA format) onto IBM
zSeries servers.
-
Converts 3270 non-SNA, Distributed Function Terminal (DFT) ESCON data
streams into LAN-based TN3270E data streams.
-
Is used as a S/390® or zSeries system console and operating system
console.
-
Connects to client PCs with 10/100 Mb Ethernet, and 4/16 MB Token Ring.
For ordering, contact:
Your IBM representative, an IBM Business Partner, or IBM Americas
Call Centers at
800-IBM-CALL
(Reference: YE001).
Overview
The IBM 2074 Model 2 is a Multiple Image Facility (MIF)-capable
console support controller with increased support for up to 64 consoles
each running TN3270E emulation. It supports non-SNA, DFT data streams
for "modern" terminal attachment. Because it is MIF-capable, multiple
systems and LPARs can simultaneously have 3270 sessions routed through
one IBM 2074 Model 2.
The IBM 2074 Model 2 is a control unit that connects to a host via a
direct ESCON® channel, via an ESCON Director, or with a FICON
Bridge. It connects to client PCs with:
-
Ethernet (10 Mb/s)
-
Fast Ethernet (100 Mb/s)
-
4 MB Token Ring
-
16 MB Token Ring
With the IBM 2074 Model 2 you can benefit from:
-
Support for up to two ESCON interfaces
-
Support for Multiple Image Facility (MIF)
-
OMA media distribution for VM and z/VM
-
Remote consoles connected via TCP/IP network
-
Consolidation of console support boxes, which can increase available
floor space
Key Prerequisites
A TN3270E emulator must be installed on each client console.
Planned Availability Date
March 29, 2002
Description
The IBM 2074 Model 2 Console Support Controller connects to a host
via a direct ESCON channel, via an ESCON Director, or with a FICON
Bridge. The IBM 2074 Model 2 connects to client console PCs
running TN3270E emulation and attached to Ethernet (10 Mb/s), Fast
Ethernet (100 Mb/s), 4 MB Token Ring, or 16 MB Token Ring local area
networks (LANs). The IBM 2074 Model 2 provides support of
non-SNA, DFT data streams to help enable current and past operating
systems to function if the 3174 and IBM 2074-001 are no longer available.
One IBM 2074 Model 2 can replace multiple 3174s or
2074 Model 1s, depending on setup and use. If you are
replacing multiple 3174s, you should purchase at least two IBM
2074 Model 2 Console Support Controllers to avoid creating a
single point of failure.
The IBM 2074 Model 2's support for up to 64 consoles can increase
the number of consoles on a single controller used for system, tape
library, VTAM®, TCP/IP, and general operations duties. It can also
provide increased capacity for configuring redundant console connections.
Euro Currency
This product is not impacted by euro currency.
Product Positioning
As the replacement for the console support function of the 3174
Establishment Controller and the IBM 2074 Model 1 Console Support
Controller, the IBM 2074 Model 2 Console Support Controller can be
used as a zSeries and S/390 system console and operating system console.
The IBM 2074 Model 2 is a protocol converter that transforms 3270
non-SNA, Distributed Function Terminal (DFT) ESCON data streams into
LAN-based TN3270E data streams.
The IBM 2074 Model 2 connects to a host via a direct ESCON channel,
via an ESCON Director, or with a FICON Bridge. It connects to client
console PCs with Ethernet (10 Mb/s), Fast Ethernet (100 Mb/s), 4 MB
Token Ring, or 16 MB Token Ring. The IBM 2074 Model 2 provides
support of non-SNA, DFT data streams to help enable current and past
operating systems to function when the 3174 and IBM 2074-001 are not
available.
One IBM 2074 Model 2 can replace multiple 3174s or
2074 Model 1s, depending on customer setup and use. The new
IBM 2074 Model 2 is now shipped with one integrated ESCON adapter
card and has an optional second ESCON adapter card feature. Each ESCON
adapter can handle up to 32 console sessions for a total of 64 console
sessions per IBM 2074 Model 2, as well as directly connecting to one
or two CEC system attachments. With the use of an ESCON Director, one
IBM 2074 Model 2 can attach to 64 different CECs. Thus one IBM 2074
Model 2 Console Support Controller can manage up to 64 LPARs or
system images.
If you are replacing multiple 3174s, you should purchase at least two IBM
2074 Model 2 Console Support Controllers to avoid creating a single
point of failure. There is no multi-path support with the IBM 2074
Model 2. Although there are two ESCON cards and both can be
attached to the same CEC, the IBM 2074 Model 2 cannot be configured
so that the loss of one connection will nondisruptively switch sessions
to the other ESCON adapter.
The IBM 2074 Model 2 is also shipped with two integrated 10/100 Fast
Ethernet adapters and two integrated 4/16 Token Ring adapters for LAN
attachment flexibility. The number of LAN attachment types is not an
orderable feature and cannot be changed.
There is no model upgrade from an IBM 2074 Model 1 to an IBM 2074
Model 2.
The IBM 2074 Model 2 OMA feature allows you to use software
distributed in the Optical Media Attach (OMA) format. Some IBM software
products, for example VM/ESA® and z/VM, distribute installation and
service in this format. The OMA feature is especially useful if you
don't have tape drives that are compatible with the product's
distribution media. The OMA feature is available for the IBM 2074
Model 1 when that model is upgraded to 2074 Driver level 1.0.8.
OMA competes with 2074 resources devoted to 3270 console I/O. It is
intended for installation and service and its use may need to be
restricted to off-peak times to avoid performance problems.
IBM representatives will review this announcement with all customers who
have an IBM 2074 Model 1 on order. The IBM 2074 Model 2 is the
replacement product for the IBM 2074 Model 1 and the IBM 3174. The
IBM 2074 Model 2 supports up to 64 client consoles, which is double
the support provided on the IBM 2074 Model 1. This allows the IBM
2074 Model 2 to provide a more scalable solution in a single
footprint. Special attention should be given if you have a requirement
for greater than 32 sessions on a single 2074. All outstanding proposals
that include an IBM 2074 Model 1 should be reviewed and updated.
New orders for console controller function for zSeries and S/390 should
specify the IBM 2074 Model 2. IBM 2074 Model 1 supply is
limited, therefore customers who require IBM 2074 Model 1s should
order as soon as possible. All IBM 2074 Model 1 orders should be
reviewed and updated as appropriate, especially if you could benefit from
the increased console capacity or are able to leverage the opportunity to
consolidate multiple controllers onto a lesser number of machines than
the Model 1 allows.
The packaging of the IBM 2074 Model 2 is different from the IBM 2074
Model 1. The IBM 2074 Model 2 now includes an integrated first
ESCON adapter, which was a separate orderable feature on the IBM 2074
Model 1. A second optional ESCON feature may still be ordered.
There is no model upgrade from an IBM 2074 Model 1 to an IBM 2074
Model 2.
Trademarks
-
-
zSeries is a trademark of International Business Machines Corporation.
-
-
FICON, z/VM, and the e-business logo are trademarks of International
Business Machines Corporation in the United States or other countries or
both.
-
-
ESCON, S/390, VTAM, and VM/ESA are registered trademarks of International
Business Machines Corporation in the United States or other countries or
both.
-
-
Other company, product, and service names may be trademarks or service
marks of others.
Publications
2074 Console Support Controller Installation and Maintenance Information
(G229-9028) is shipped with the product. Additional copies are
available upon request or from the Web on Resource Link. The Resource
Link location is:
2074 Console Support Controller Configuration Guide
(SC28-6806) is available from the Web on Resource Link or through your
IBM representative. The Resource Link location is:
Technical Information
Specified Operating Environment
Physical Specifications
Size:
The IBM 2074 Model 2 package is a rack model box measuring
approximately:
-
Width: 17.30 inches (standard 19-inch rack)
-
Height: 5.00 inches (3U)
-
Depth: 27.30 inches
The following additional space is required for the machine to function
properly:
-
Fifty millimeters must be allowed on both the left side and the right
side for air flow.
-
A 100-mm clearance should be allowed in the rear for cables.
Weight:
IBM 2074 Model 2 system weight can be approximately 60
pounds when fully configured.
Operating Environment
Temperature, Humidity, and Altitude
Max Wet
Class B Extended Temperature Altitude Humidity Bulb Temp
Environment (Degrees C) (Meters) (Percent) (Deg C)
Product Operating 10-35 0-914 8-80 23
10-32 914-2,133 8-80 23
Product Power Off 10-43 8-80 27
Machine Storage 1-60 5-80 29
Machine Shipment -40-60 5-100(1) 29
-
1
-
Including condensation but excluding rain
Electromagnetic Compatibility:
The IBM 2074 Model 2 will meet worldwide class "A" EMC
requirements (such as FCC class A, CE Mark EMC requirements, CISPR 22
Class A, and VCCI class 1).
Power Requirements:
The IBM 2074 Model 2 needs the following nominal power:
-
100-127 V ac 50 Hz or 60 Hz
-
200-240 V ac 50 Hz or 60 Hz
Hardware Requirements
A TN3270E emulator must be installed on each client console. Clients
consoles should be at least 500 MHz, have 128 MB memory, and have
accelerated graphics with at least 8 MB video memory. A 21-inch display
is recommended to allow viewing of many console sessions at once.
If more than one IBM 2074 Model 2 is installed in the same rack,
then a keyboard/video/mouse (KVM) sharing console switch should be
considered. With a console switch you can have one
keyboard/mouse/display controlling multiple IBM 2074s. The use of a KVM
sharing switch could complicate service issues, and might have to be
removed to diagnose certain problems. A spare keyboard, mouse, and
display would allow problem isolation without disrupting the other 2074s
sharing the switch.
We recommend the IBM NetBAY Console Switch.
Each IBM 2074 Model 2 must have a keyboard, mouse, and display
attached at all times. If you are using a console switch, then it
provides this function when the active keyboard, mouse, and display are
switched away.
Software Requirements
The IBM 2074 Model 2 requires no specific S/390® or IBM
zSeries software. No user code will run on this box. The IBM 2074
Model 2 is compatible with existing 3270 data streams for VM,
VM/ESA®, z/VM, VSE/ESA, MVS, TPF, OS/390®, z/OS, Linux,
and z/OS.e, including back-level releases.
The IBM 2074 Model 2 is shipped with a custom CD-ROM that is
preloaded onto the IBM 2074 Model 2 hard drive. The software on
this CD-ROM is IBM Licensed Internal Code and may be used only under the
LIC license for operation of the IBM 2074 Model 2 Console Support
Controller. The customer must use the configuration utility to customize
the box. The configuration utility is based on the Multiprise® 3000
"EMIO configuration" utility AWSCFG. The same IOCP/HCD must be done for
the IBM 2074 Model 2 as for the 3174. However, the IBM 2074
Model 2 supports shared MIF channels.
Client PCs attach to an IBM 2074 Model 2 via Token Ring or Ethernet
adapters using a TN3270E data stream. This means that the client must
have a TN3270E emulator installed. IBM has tested the eNetwork Personal
Communications V5.0 emulator running under Windows® 98 for
compatibility, however there is no reason to believe that other
compatible emulators will not work. Please contact the emulator product
vendor directly for terms, conditions, prices, and other product details
related to such vendor's emulator.
Compatibility:
The IBM 2074 Model 2 Console Support Controller can be attached
directly to the host via an ESCON® channel, or through an ESCON
Director, or via a FICON Bridge. Because the IBM 2074 Model 2 is
MIF-capable, one control unit can support multiple LPARs and CECs,
creating the opportunity for you to conserve floor space by replacing
multiple 3174s. Although an individual console session cannot be shared
between LPARs, a single IBM 2074 Model 2 controller can have console
sessions configured in different LPARs, in different CECs, and on
different channels.
Limitations:
The IBM 2074 Model 2 supports only TN3270E clients.
Although there is a total of 64 TN3270E sessions available, only two of
these sessions may be configured locally on the 2074's display itself and
then only for debugging, not production purposes.
The IBM 2074 Model 2 contains four LAN adapters, two of each kind.
Two LAN adapters can't be connected to the same subnet. OS/2® doesn't
support load balancing. The multiple LAN adapters are to allow you to
connect to four different subnets.
There is no multi-path support with the IBM 2074 Model 2. Although
there are two ESCON cards and both can be attached to the same CEC, the
IBM 2074 Model 2 cannot be configured so that the loss of one
connection will nondisruptively switch sessions to the other ESCON
adapter.
If more than one IBM 2074 Model 2 is installed in the same rack,
then a keyboard/video/mouse (KVM) sharing console switch should be
considered. With a console switch you can have one
keyboard/mouse/display controlling multiple IBM 2074s. The use of a KVM
sharing switch could complicate service issues, and might have to be
removed to diagnose certain problems. A spare keyboard, mouse, and
display would allow problem isolation without disrupting the other 2074s
sharing the switch.
Planning Information
Customer Responsibilities:
The IBM 2074 Model 2 Console Support Controller is classified
as a CE-installed box. IBM customer engineers will be involved in the
installation and installation planning activities. The customer must use
the configuration utility to configure the box to customize the following
items:
-
LAN adapters
-
LAN adapter IP addresses
-
Frame type for each Ethernet Adapter (IEEE or DIX)
-
Definition of the 32 possible sessions on each ESCON adapter card:
-
The source definition on the ESCON side: LPAR number, unit address,
destination port number, and so on
-
The target definition for the client: IP address and/or LUNAME
-
Selection of a device type for each session: display (3278), printer
(3287), or OMA tape (3422)
-
TCP/IP port number definition for each ESCON adapter
Customers should also consider TCP/IP security technologies (for example,
the creation of a Virtual Private Network [VPN] or Virtual LAN
[VLAN]) as methods to increase security, especially if planning to
use console sessions over remote TCP/IP connections.
Cable Orders:
ESCON and LAN cables are supplied by the customer.
Security, Auditability, and Control
This product uses the security and auditability features of zSeries
servers.
Customers should also consider TCP/IP security technologies (for example,
the creation of a VPN or VLAN) as methods to increase security,
especially if planning to use console sessions over remote TCP/IP
connections.
The customer is responsible for evaluation, selection, and implementation
of security features, administrative procedures, and appropriate controls
in application systems and communications facilities.
Terms and Conditions
This product is available for purchase under the terms of the IBM
Customer Agreement.
IBM hardware products are manufactured from new parts, or new and used
parts. In some cases, the hardware product may have been previously
installed.
Regardless, IBM warranty terms apply.
IBM Credit Corporation Financing:
No
Warranty Period:
One year
Warranty Service:
IBM On-Site Repair (IOR) 24 hours a day, 7 days a week, same-day
response
Usage Plan Machine:
No
IBM Hourly Service Rate Classification:
Three
When a type of service involves the exchange of a machine part, the
replacement may not be new, but will be in good working order.
Rental Offering:
No
Field-Installable Features:
Yes
Model Conversions:
No
Customer Setup:
No
Graduated Charges:
No
Licensed Internal Code:
IBM Licensed Internal Code is licensed for use by a customer on a
specific machine, designated by serial number, under the terms and
conditions of the IBM Agreement for Licensed Internal Code.
Educational Allowance:
A reduced charge is available to qualified education customers. The
educational allowance may not be added to any other discount or
allowance.
Prices
Contact your IBM representative for charges information for this
announcement.
Order Now
Use Priority/Reference Code: YE001
Phone: 800-IBM-CALL
Fax: 800-2IBM-FAX
Internet: ibm_direct@vnet.ibm.com
Mail: IBM Atlanta Sales Center
Dept. YE001
P.O. Box 2690
Atlanta, GA 30301-2690
You can also contact your local IBM Business Partner or IBM
representative. To identify them, call 800-IBM-4YOU.
Note:
Shipments will begin after the planned availability date.
Trademarks
-
-
zSeries is a trademark of International Business Machines Corporation.
-
-
Resource Link, MVS, VSE/ESA, z/VM, z/OS, FICON, and the e-business logo
are trademarks of International Business Machines Corporation in the
United States or other countries or both.
-
-
S/390, VM/ESA, OS/390, Multiprise, ESCON, and OS/2 are registered
trademarks of International Business Machines Corporation in the United
States or other countries or both.
-
-
Windows is a registered trademark of Microsoft Corporation.
-
-
Other company, product, and service names may be trademarks or service
marks of others.
|