Feedback

New IBM System Storage SAN Volume Controller Storage Engine offers 10 Gigabit Ethernet connectivity

IBM United States Hardware Announcement 111-083
May 9, 2011


Table of contents
Overview Overview Publications Publications
Key prerequisites Key prerequisites Technical information Technical information
Planned availability date Planned availability date Terms and conditions Terms and conditions
Description Description Pricing Pricing
Product number Product number Order
now Order now


Top rule
At a glance
Bottom rule

For enterprises seeking to improve the cost effectiveness, flexibility, productivity, and availability of their storage infrastructure, IBM® System Storage® SAN Volume Controller (SVC) (2145-CG8) provides a combined hardware and software storage virtualization system designed to centralize and consistently manage and operate heterogeneous storage environments.

The SVC solution can help:

  • Simplify storage infrastructures and reduce costs by combining the capacity from multiple disk storage systems into pools managed from a central point
  • Get more out of existing storage assets by improving utilization, automating, and provisioning, and by making storage more accessible to host applications
  • Improve administrator productivity
  • Avoid storage-related causes of application downtime, including data migrations

The new SVC Storage Engine adds 10 Gigabit Ethernet connectivity to help improve throughput.

This solution includes a Common Information Model (CIM) Agent to enable unified storage management based on open standards for units that comply with CIM Agent standards.

For ordering, contact your IBM representative, an IBM Business Partner, or IBM Americas Call Centers at 800-IBM-CALL (Reference: YE001).



Back to topBack to top
 
Top rule
Overview
Bottom rule

The IBM System Storage SAN Volume Controller Storage Engine (machine type 2145 Model CG8) is the hardware component of the IBM System Storage SAN Volume Controller (SVC). The SVC solution includes highly specialized software, storage engines installed in pairs, and power connection equipment, such as an Uninterruptible Power Supply (UPS).

The SVC Storage Engine is based on the IBM System x3550M3 hardware platform. Four 8 Gbps Fibre Channel ports, 24 GB of cache in each engine, and the option to add 10 Gigabit Ethernet connectivity with two ports per SVC hardware engine, the SVC Storage Engine is designed to provide high performance and scalability.

IBM System Storage SVC Storage Engine now provides the option to add 10 Gigabit Ethernet connectivity with two ports per SVC hardware engine.

Feature exchange

None



Back to topBack to top
 
Top rule
Key prerequisites
Bottom rule

The full interoperability matrix for the SVC solution is available at

http://www.ibm.com/storage/support/2145

IBM System Storage SAN Volume Controller Storage Software must be ordered separately. For additional details, refer to Software Announcement 211-175, dated May 09, 2011.



Back to topBack to top
 
Top rule
Planned availability date
Bottom rule

  • June 10, 2011: SAN Volume Controller 2145-CG8 new order shipments begin


Back to topBack to top
 
Top rule
Description
Bottom rule

The IBM System Storage SVC Solution is designed to incorporate specialized software, SVC Storage Engines installed in pairs, a System Storage Productivity Center console or hardware master console, and UPSs. The SVC hardware configuration consists of a cluster of IBM 2145 servers, called SVC Storage Engines. Each SVC Storage Engine is a node; two nodes make up a node pair (I/O Group); up to four I/O Groups constitute an SVC cluster. The cluster is scalable from one to four node pairs (I/O Groups), and is supported by dual read/write cache. This design is intended to avoid single points of failure and support concurrent maintenance.

IBM System Storage SAN Volume Controller Storage Engine (2145-CG8)

IBM SVC Storage Engine is based on the IBM System x3550M3, has an Intel® Core Xeon® 5600 Series quad-core processor, two power supply units, 24 GB of cache, and four 8 Gbps Fibre Channel host bus adapter (HBA) ports for attachment to the SAN. SVC Storage Engine Model CG8 auto-negotiates the fabric speed on a per-port basis and is not restricted to run at the same speed as other node pairs in the cluster.

The IBM SVC Storage Engine can be added in pairs to an existing cluster of Model 8F2, Model 8F4, Model 8G4, Model 8A4, Model CF8, or Model CG8 engines, up to the maximum of four node pairs. SVC Storage Engine Model 4F2 cannot run SVC V6 software that comes preloaded on the SVC Storage Engine Model CG8, therefore a unique procedure is required to migrate from Model 4F2 to Model CG8 in an existing cluster. Refer to the support web page and SVC documentation for details

http://www.ibm.com/storage/support/2145

One UPS - single (#8115) must also be ordered for each SVC Storage Engine. For more details, refer to the Miscellaneous features section.

The SVC Storage Engine is shipped with preloaded SVC Storage Software V6.2.0 (ordered separately). SVC hardware will not be shipped without a companion order for the software. For a description of the software and ordering procedures, refer to Software Announcement 211-175, dated May 09, 2011.

The storage engines must be installed in pairs to enable load sharing and failover protection. Four optical fiber cables are required by each engine in the cluster for connection to the Fibre Channel switches in the SAN. These cables are not provided as part of the engine, but may be ordered by feature number.

Each SVC Storage engine has two 1Gb Ethernet ports for connection via Ethernet LAN to the System Storage Productivity Center that provides configuration and error reporting, or for other functions as designated. These connections need to be aggregated through an Ethernet hub or switch. The Ethernet hub or switch and cabling are not included as part of the SVC.

SVC Storage Engine Model CG8 engines can replace all earlier models of the SVC Storage Engines in a cluster without disrupting applications running on the host. If replacing a Model 4F2 engine (32-bit hardware), unique procedures are required to perform the migration. Refer to the support web page and SVC documentation for details

http://www.ibm.com/storage/support/2145

To have the new nodes replace existing nodes in an existing configuration, you must order feature number 3905 for one, and only one, of the replacement nodes that are being ordered. Feature number 3905 directs the service representative to remove the old nodes from the existing rack.

10 Gigabit Ethernet Connectivity

SVC now comes with the option to add a 10 Gigabit Ethernet card with two ports. Use of this 10 Gbps Ethernet connectivity option is determined by software functions available on the SVC, such as 10 Gigabit iSCSI. On a single storage engine, customers may optionally choose to use either internal solid-state devices or add 10 Gigabit Ethernet connectivity. Both options cannot coexist on the same storage engine.

System Storage Productivity Center

IBM System Storage Productivity Center must be ordered via AAS regardless of whether SVC V6 is ordered via AAS or Passport Advantage®.

Code preload

Storage Engine Preload (#0010)

This feature provides the required SVC Storage Software that must be preloaded by IBM on the SVC Storage Engine and must be included with each SVC Storage Engine ordered. This feature is plant-installed only.

Storage Engine Preload PA (#0017)

This feature specifies that the software order be fulfilled via Passport Advantage. This feature must be included in the order for the first SVC Storage Engine ordered for a cluster (#3001), unless the software order is to be fulfilled via AAS (#0018). The order for SVC Storage Software V6 must be placed separately via Passport Advantage. This feature is plant-installed only and is mutually exclusive of feature numbers 0018 and 0019.

Storage Engine Preload AAS (#0018)

This feature specifies that the software order be fulfilled via AAS. This feature must be included in the order for the first SVC Storage Engine ordered for a cluster (#3001), unless the software order is to be fulfilled via Passport Advantage (#0017). The order for SVC Storage Software V6 must be placed separately via AAS. This feature is plant-installed only and is mutually exclusive of feature numbers 0017 and 0019.

Secondary cluster (#0019)

This feature is for administrative purposes only and specifies that the order for a new cluster is not for the first cluster to be installed for the customer. It specifies that this is for a subsequent cluster to be installed for the same customer. Specifying feature number 0019 will verify that no software is to be ordered and that a software license is already in effect for a cluster installed for the customer. This feature is plant-installed only and is mutually exclusive of feature numbers 0017 and 0018.

Miscellaneous features

JEMT Indicator (#0021)

This feature is used to indicate an IBM internal order for machine under the Joint Engineering Manufacturing Test (JEMT) program. It is for administrative purposes only.

Engines

Initial Storage Engine (#3001)

Feature number 3001 is used to indicate the first SVC Storage Engine of a new SVC cluster. It must be included for one, and only one, SVC Storage Engine in a new cluster order. An order for the SVC Storage Software V6 (5639-VC6, or 5639-SX1, or both) must be placed when feature number 3001 is ordered. This feature also provides the publications included with the first SVC Storage Engine in the cluster. This feature is plant installed only.

Additional Storage Engine (#3002)

Feature number 3002 is used to indicate all additional SVC Storage Engines of a SVC cluster and for all SVC Storage Engines to be added to an existing (already installed) SVC cluster. When ordered as part of a new cluster, the number must be an odd number (1, 3, 5, or 7); when ordered to add to an existing cluster, the number must be even (2, 4, or 6). This feature is plant installed only.

SVC engine removal (#3905)

Feature number 3905 indicates that installed engines are to be removed from the rack by an IBM service representative. This feature should be specified only for an engine that is intended to replace a currently installed engine. The feature may be specified for only one replacement engine per order of replacements.

Solid-State Device Attachment (#4500)

This is an optional feature that is required if you are installing one or more 146 GB Solid-State Device (#4601) on the SVC Storage Engine. The Solid-State Device Attachment consists of a SAS adapter and an internal connector cable installed on the hardware engine. Only one Solid-State Device Attachment feature (#4500) can be installed per engine, and when selected, you cannot select the 10 Gigabit Ethernet Attachment (#5700) feature. This feature is both plant- and field-installed.

146 GB Solid-State Device (#4601)

This is an optional feature to install 146 GB solid state devices directly on the SVC Storage engine. The Solid-State Device Attachment feature (#4500) must be ordered with one or more 146 GB Solid-State Devices (#4601). Up to a quantity of four of this feature number 4601 can be ordered per hardware engine, and it is advised that they be configured in a RAID array or be ordered in the same quantity for each engine in a node pair for data protection purposes. For example, if you are ordering a 4-node cluster, but you want to have 146 GB solid state capacity, you should order two 146 GB Solid-State Device features (#4601), one on each of two nodes in that 4-node cluster. Another example is if you wish to configure 292 GB usable capacity on an SVC 4-node cluster. Two of the nodes can be ordered without features #4500 and #4601. Each of the other two nodes in the cluster should be configured with a quantity of one feature #4500 and a quantity of two of feature #4601. These nodes should be paired together when configuring the SVC cluster so that the solid-state devices are mirrored for data protection. To maximize usable SSD capacity, you may optionally mirror the solid-state device(s) to other storage managed by the SVC that is not necessarily on solid-state devices. This approach is only suggested for workloads with primarily read I/Os since write I/O performance will be dependent on the non-SSD storage. In any case, mirroring the solid-state devices is strongly advised for data protection. Refer to the support web page and SVC documentation for details

http://www.ibm.com/storage/support/2145

This feature is both plant- and field-installed.

10 Gigabit Ethernet Attachment (#5700)

This is an optional feature that is required if you are installing the 10 Gigabit Ethernet Optical SW SFP pair (#5711) on the IBM System Storage SAN Volume Controller Storage Engine. Only one 10 Gigabit Ethernet Attachment feature (#5700) can be installed per engine, and when selected, you cannot select the solid-state Device Attachment (#4500) feature. This feature is both plant- and field-installed.

IBM 10 Gigabit Ethernet Optical SW SFP pair (#5711)

This is an optional feature to install a pair of 10 Gigabit Ethernet Optical shortwave SFPs directly on the SVC Storage Engine. The 10 Gigabit Ethernet Attachment feature (#5700) must be ordered with each 10 Gigabit Ethernet Optical SW SFP pair (#5711). A maximum quantity of one of this feature number (#5711) can be ordered per hardware engine, and it enables two 10 Gigabit Ethernet ports. This feature is both plant- and field-installed.

Cables, interfaces, and power

5 m Fiber Optic Cable LC-LC (#5305)

This feature provides one 5-meter, fiber optic cable with LC connectors on each end. Six of this feature may be ordered with each SVC Storage Engine. This feature is both plant and field ordered but customer-installed.

25 m Fiber Opt Cable LC-LC (#5325)

This feature provides one 25-meter, fiber optic cable with LC connectors on each end. Six of this feature may be ordered with each SVC Storage Engine. This feature is both plant and field ordered but customer-installed.

8 Gbps LW SFP (#5608)

SVC V5.1 introduced the ability to split a SVC I/O group across long distances. The 8 Gbps LW SFP feature #5608 is currently the only supported hardware for use in these configurations. Your SAN must also meet documented requirements before implementing such a configuration. Refer to the support web page and SVC documentation for details

http://www.ibm.com/storage/support/2145

This feature is both plant and field ordered but customer-installed.

Uninterruptible Power Supply (UPS) (#8115)

In the event of a power failure, the UPS can provide temporary power while the contents of the SVC cache and cluster information is written to the internal disk drive of each node of the SVC.

The UPS monitors the condition of its battery to enable planned maintenance actions to be performed. Each UPS provides an independent source of power to the node to which it is connected. It must not be used for any other purpose.

The UPS - single feature (#8115) provides one UPS for one SVC Storage Engine of the SVC cluster. One UPS - single (#8115) must be ordered for each engine of a cluster, both for the initial engine (#3001) and for additional engines (#3002).


Note: The UPS that is feature #8115 of a previous SVC Storage Engine model, such as 2145-8F4, is not compatible for use in place of the UPS that is feature #8115 of the current SVC Storage Engine model (2145-CG8).

Each UPS - single (#8115) requires a 200-240 V, minimum 5 amp power source; the UPS - single (#8115) is protected by its own 10 amp circuit breaker. UPSs of a node pair (I/O group) should be connected to separate circuits to provide added redundancy.

A power cord to connect the UPS to a standard PDU ships standard with the UPS. A country-specific power cord to connect to an alternate power source must also be ordered with the UPS. This feature may be mixed with UPS feature number 8100 only in an SVC configuration running SVC Storage Software V2, or later. For configurations running SVC Software V1, UPS feature number 8100 must be used; V1 does not support feature number 8115.

For clusters of two or six engines, the use of UPS - single (#8115) may result in a lower-price solution. UPS feature number 8100 supports up to four nodes. This feature is both plant- and field-installed.

Redundant AC Power (#8300)

This is an optional feature designed to enhance reliability by accepting power from two separate circuits. Each Redundant AC Power switch can be used to supply power to one or two SVC UPSs (#8115). The preferred configuration is one Redundant AC Power switch for each SVC UPS (each SVC storage engine). If two SVC UPSs are powered by a single Redundant AC Power switch, the two nodes must not be in the same I/O group. In the event of the failure of either of the input circuits, power continues to be provided to the SVC UPS by the redundant circuit.

This feature is designed to provide power to UPS feature number 8115 only; it must not be used for any other purpose.

Each of the two power sources are required to be 200-240 V, minimum 5 amp, 50/60 Hz, single phase, and to have IEC320-C19 type outlets. The power cable (cord), between the Redundant AC Power switch and each connected SVC UPS, is rated at 10 amps.

Each input circuit for the Redundant AC Power switch must be protected by a circuit breaker with maximum rating of 16 amps. Where the Redundant AC Power switch is used to supply a single UPS, a circuit breaker with a minimum rating of 5 amps is required. If two UPSs are being powered then a breaker with a minimum rating of 7 amps is required.

Power cords to connect the redundant ac power switch to a standard PDU ships standard with the switch. The redundant ac power switch connects to a rack PDU only. There are no separate country-specific power cords for the switch. This optional feature is both plant- and field-installable.

Accessibility by people with disabilities

For hardware offerings

The following features support use by people with disabilities:

  • Controls and latches are operable with one hand and minimal dexterity
  • The keys on the panel are tactilely discernible without activating them

A U.S. Section 508 Voluntary Product Accessibility Template (VPAT) containing details on accessibility compliance can be requested at

http://www.ibm.com/able/product_accessibility/index.html


Back to topBack to top
 
Top rule
Reference information
Bottom rule

For more information on SVC V6 software that is preloaded on the 2145-CG8, refer to Software Announcement 211-175, dated May 09, 2011.

For information on the System Storage Productivity Center, refer to Hardware Announcement 110-255, dated November 23, 2010.

For IBM statement on compliance with European Union Directive on Restriction of the use of certain Hazardous Substances in Electrical and Electronic Equipment (2002/95/EC) (RoHS), visit

http://www.ibm.com/ibm/environment


Back to topBack to top
 
Top rule
Product number
Bottom rule

 
                                                     Plant/
Description                    Machine Model Feature Field   CSU*

SVC Storage Engine              2145    CG8
Storage Engine Preload SVC SW   2145    CG8   0010   Plant   No
Storage Engine Preload PA       2145    CG8   0017   Plant   No
Storage Engine Preload AAS      2145    CG8   0018   Plant   No
Secondary HW cluster            2145    CG8   0019   Plant   No
JEMT Indicator                  2145    CG8   0021   Plant   No
RFID tag - discretionary        2145    CG8   0203   Plant   No
Initial Storage Engine          2145    CG8   3001   Plant   No
Additional Storage Engine       2145    CG8   3002   Plant   No
SVC engine removal              2145    CG8   3905   Both    No
Solid-State Device Attachment   2145    CG8   4500   Both    No
146GB Solid-State Device        2145    CG8   4601   Both    No
5 m Fiber Optic Cable LC-LC     2145    CG8   5305   Both    Yes
25 m Fiber Opt Cable LC-LC      2145    CG8   5325   Both    Yes
IBM 8Gbps LW SFP                2145    CG8   5608   Both    Yes
10 Gigabit Ethernet Attachment  2145    CG8   5700   Both    No
IBM 10GbE Optical SW SFP pair   2145    CG8   5711   Both    Yes
UPS - Single                    2145    CG8   8115   Both    No
Redundant AC Power              2145    CG8   8300   Both    No
 
UPS (#8115) POWER (LINE) CORDS:
 
UPS-8115 Power Cord (#1)        2145    CG8   9714   Both    No
 U.S. 250V/10A 6 ft
UPS-8115 Power Cord (#2)        2145    CG8   9715   Both    No
 US/Japan/S.America 9 ft
UPS-8115 Power Cord (#3)        2145    CG8   9716   Both    No
 Eur,Mid-East,Africa
UPS-8115 Power Cord (#4)        2145    CG8   9717   Both    No
 Austral,N.Z.
UPS-8115 Power Cord (#5)        2145    CG8   9718   Both    No
 Eur,Africa
UPS-8115 Power Cord (#6)        2145    CG8   9719   Both    No
 Eur,Den
UPS-8115 Power Cord (#7)        2145    CG8   9720   Both    No
 Pakistan,S.Africa
UPS-8115 Power Cord (#8)        2145    CG8   9721   Both    No
 Switz,Liechtenstein
UPS-8115 Power Cord (#9)        2145    CG8   9722   Both    No
 Chile,Italy,Ethiopia
UPS-8115 Power Cord (#10)       2145    CG8   9723   Both    No
 Israel
UPS-8115 Power Cord (#11)       2145    CG8   9724   Both    No
 Thailand
UPS-8115 Power Cord (#12)       2145    CG8   9725   Both    No
 Argentina
UPS-8115 Power Cord (#13)       2145    CG8   9726   Both    No
 China
UPS-8115 Power Cord (#14)       2145    CG8   9727   Both    No
 Taiwan
 
* CSU:  Customer Setup
 

Business Partner information

If you are a Direct Reseller - System Reseller acquiring products from IBM, you may link directly to Business Partner information for this announcement. A PartnerWorld® ID and password are required (use IBM ID).

https://www.ibm.com/partnerworld/mem/sla.jsp?num=111-083


Back to topBack to top
 
Top rule
Education support
Bottom rule

Courses regarding SVC planning, usage, and benefits can be found at

http://www.ibm.com/training/global

Search on coursecode = SN82G or coursecode = SN83G or select your country/region, then search on course code.



Back to topBack to top
 
Top rule
Publications
Bottom rule

The following publications are shipped as hardcopy with the initial hardware engine.

                                            Order
 Title                                      number

 IBM System Storage SAN Volume Controller   GC27-3923
 Model 2145-CG8 Hardware Installation Guide
 
 IBM System Storage SAN Volume Controller   GC27-2283
 Hardware Maintenance Guide
 
 IBM System Storage SAN Volume Controller   GC27-2284
 Troubleshooting Guide
 
 IBM System Storage SAN Volume Controller   GA32-0843
 Read First
 
 IBM System Storage SAN Volume Controller   SK5T-8811
 Customer Documentation
   (DVD containing all documentation)
 

You can use the following options to order or download additional copies:

The IBM Publications Center

Hardcopy of selected SAN Volume Controller publications are available for a fee from the IBM Publications Center, as well as free softcopy publications. The Publications Center is a worldwide central repository for IBM product publications and marketing material with a catalog of 70,000 items. Extensive search facilities are provided. Payment options for orders are via credit card or customer number. A large number of publications are available online in various file formats, and they can all be downloaded free of charge.

Additional publications information

  • To order additional selected hardcopy publications for a fee or download free PDF format publications, visit the IBM Publications Center website
    http://www.ibm.com/shop/publications/order
  • To directly download publications in PDF format, visit the IBM product support website
    http://www.ibm.com/storage/support/2145
  • Call the Publications Support Group at 800-879-2755, and select option 1.
  • Contact your IBM representative


Back to topBack to top
 
Top rule
Services
Bottom rule

Global Technology Services

IBM services include business consulting, outsourcing, hosting services, applications, and other technology management.

These services help you learn about, plan, install, manage, or optimize your IT infrastructure to be an On Demand Business. They can help you integrate your high-speed networks, storage systems, application servers, wireless protocols, and an array of platforms, middleware, and communications software for IBM and many non-IBM offerings. IBM is your one-stop shop for IT support needs.

For details on available services, contact your IBM representative or visit

http://www.ibm.com/services/

For details on available IBM Business Continuity and Recovery Services, contact your IBM representative or visit

http://www.ibm.com/services/continuity

For details on education offerings related to specific products, visit

http://www.ibm.com/services/learning/index.html

Select your country, and then select the product as the category.



Back to topBack to top
 
Top rule
Technical information
Bottom rule

Specified operating environment

Physical specifications

SVC Storage Engine

  • Width: 440 mm (17.3 in)
  • Depth: 737 mm (29 in)
  • Height: 43 mm (1.7 in)
  • Weight: 14.0 kg (30.3 lb)

UPS - single (#8115)

  • Width: 440 mm (17.3 in)
  • Depth: 578 mm (22.8 in)
  • Height: 44 mm (1.73 in)
  • Weight: 19 kg (42 lb)

Note: These dimensions represent a single UPS.

Redundant AC Power (#8300)

  • Width: 192 mm (7.6 in)
  • Depth: 221 mm (8.7 in)
  • Height: 44.5 mm (1.75 in)
  • Weight: 2.6 kg (5.7 lb)

To assure installability and serviceability in non-IBM industry-standard racks, review the installation planning information for any product specific installation requirements.

Operating environment

SVC Storage Engine

  • Temperature (operating):
    • 10° to 35° C (50° to 95° F) at 0 to 914 m (0 to 3,000 ft)
    • 10° to 32° C (50° to 90° F) at 914 to 2,133 m (3,000 to 7,000 ft)
  • Temperature (powered off): 10° to 43° C (50° to 109° F)
  • Temperature (storage): 1° to 60° C (34° to 140° F) at 0 to 2,133 m (0 to 7,000 ft)
  • Temperature (shipping): -20° to 60° C (-4° to 140° F) at 0 to 10,668 m (0 to 35,000 ft)
  • Electrical power: 200-240 Vac, 3.8 A, 50/60 Hz
  • Relative humidity (operating and powered off): 8% to 80%
  • Relative humidity (storage): 5% to 80%
  • Relative humidity (shipping): 5% to 100% (including condensation but excluding rain)
  • Wet bulb:
    • Wet bulb (operating temp): 23° C
    • Wet bulb (powered off temp): 27° C
    • Wet bulb (storage and shipping temp): 29° C
  • Noise level: 6.5 bels LwAd - when operating in a 2146 system rack

Note: The noise emission level stated is the declared (upper limit) sound power level, in bels, for a random sample of machines. All measurements are made in accordance with ISO 7779 and reported in conformance with ISO 9296.

UPS - single (#8115)


Note: The specifications for the UPS are taken from specifications provided by the manufacturer and are presented for reference only. For use in the SVC environment, the UPS has been programmed to shut down outside of the range of 200-240 V.
  • Temperature (operating): 0° to 40° C (32° to 104° F) at 0-1,500 m (0-4,921 ft) above sea level
  • Temperature (operating): 0° to 35° C (32° to 95° F) at 1,500-3,000 m (4,921-9,842 ft) above sea level
  • Temperature (powered off): 0° to 40° C (32° to 104° F) at 0-1,500 m (0-4,921 ft) above sea level
  • Temperature (storage and shipping): -15° to 55° C (5° to 131° F) at 0-1,500 m (0-4,921 ft) above sea level
  • Relative humidity (operating and powered off): 5% to 95%
  • Relative humidity (storage): 5% to 95%
  • Relative humidity (shipping): 5% to 95% (noncondensing)
  • Wet bulb:
    • Wet bulb (operating temp): 23° C
    • Wet bulb (powered off temp): 27° C
    • Wet bulb (storage and shipping temp): 29° C
  • Noise level: 5.2 bels LwAd - Declared (upper limit) A-weighted sound power level 36 dB A-weighted sound pressure level (bystander positions).

Note: The noise emission levels are reported in conformance with ISO 9296 with measurements made according to ISO 7779.

Redundant AC Power (#8300)

  • Temperature (operating): 15° to 32° C (59° to 90° F) at 0 to 2133 m (0 to 7,000 ft)
  • Relative humidity (operating and powered off): 20% to 80%
  • Temperature (powered off): 10° to 43° C (50° to 109° F)
  • Temperature (storage): 1° to 60° C (34° to 140° F) at 0 to 2,133 m (0 to 7,000 ft)
  • Temperature (shipping): -20° to 60° C (-4° to 140° F) at 0 to 10,668 m (0 to 35,000 ft)
  • Relative humidity (storage): 5% to 80%
  • Relative humidity (shipping): 5% to 100% (including condensation but excluding rain)
  • Wet bulb:
    • Wet bulb (operating temp): 23° C
    • Wet bulb (powered off temp): 27° C
    • Wet bulb (storage and shipping temp): 29° C
  • Electrical power: 200-240 V ac, 10 A, 50/60 Hz
Hardware requirements
UPS - single (#8115) requirements

Each UPS - single (#8115) in the cluster must be provided a single-phase 200-240 volt, minimum 5 amp, 50 or 60 Hz power source. It is not required, but recommended, that the UPS for each node of a node pair be on a separate, independent, circuit to provide added redundancy in the system structure.

A power cord to connect the UPS (#8115) to a standard PDU ships standard with the UPS.

In addition, a country-specific power cord must be specified by feature number for connection to wall-type outlets should the rack not have a compatible PDU or if the PDU has wall-type outlets. One of the following power cord specify features is required to connect the UPS to the alternate power source.

Each power cord feature provides one country-specific power cord. Countries supported by these features include:

  • UPS-8115 Power Cord (#1) (#9714)
    • Provides power cords for U.S., Canada, Mexico, and others
    • Six feet (1.8 m), unshielded, rated 250 V/15 A
    • Attached plug (NEMA L6-15P) designed for 200-240 V ac input
    • Part number: 39M5115
  • UPS-8115 Power Cord (#2) (#9715)
    • Provides power cords for U.S., Bahamas, Barbados, Bermuda, Bolivia, Brazil, Canada, Cayman Islands, Colombia, Costa Rica, Dominican Republic, Ecuador, El Salvador, Guatemala, Guyana, Haiti, Honduras, Jamaica, Japan, Korea (South), Liberia, Mexico, N. Antilles, Nicaragua, Panama, Peru, Philippines, Saudi Arabia, Suriname, Taiwan, Trinidad, and Venezuela
    • Nine feet (2.8 m), unshielded, rated 250 V/15 A
    • Attached plug (NEMA L6-15P) designed for 200-240 V ac input
    • Part number: 39M5116
  • UPS-8115 Power Cord (#3) (#9716)
    • Provides power cords for Antigua, Bahrain, Brunei, Channel Islands, China (Hong Kong S.A.R.), Cyprus, Dubai, Figi, Ghana, India, Iraq, Ireland, Kenya, Kuwait, Malawi, Malaysia, Malta, Nepal, Nigeria, Polynesia, Qatar, Sierra Leone, Singapore, Tanzania, Uganda, UK, Yemen, and Zambia
    • Nine feet (2.8 m), unshielded, rated 250 V/10 A
    • Attached plug (BS 1363/A) designed for 200-240 V ac input
    • Part number: 39M5151
  • UPS-8115 Power Cord (#4) (#9717)
    • Provides power cords for Argentina, Australia, China (PRC), New Zealand, Papua New Guinea, Paraguay, Uruguay, and Western Samoa
    • Nine feet (2. 8 m), unshielded, rated 250 V/10 A
    • Attached plug (AS/NZS C112) designed for 200-240 V ac input
    • Part number: 39M5102
  • UPS-8115 Power Cord (#5) (#9718)
    • Provides power cords for Afghanistan, Albania, Algeria, Andorra, Angola, Austria, Belgium, Benin, Bulgaria, Burkina Faso, Burundi, Cameroon, Central African Rep., Chad, China (Macau S.A.R.), Czech Republic, Egypt, Finland, France, French Guiana, Germany, Greece, Guinea, Hungry, Iceland, Indonesia, Iran, Ivory Coast, Jordan, Lebanon, Luxembourg, Malagasy, Mali, Martinique, Mauritania, Mauritius, Monaco, Morocco, Mozambique, Netherlands, New Caledonia, Niger, Norway, Poland, Portugal, Romania, Senegal, Slovakia, Spain, Sudan, Sweden, Syria, Togo, Tunisia, Turkey, former USSR, Vietnam, former Yugoslavia, Zaire, and Zimbabwe
    • Nine feet (2.8 m), unshielded, rated 250 V/10 A
    • Attached plug (CEE 7-VII) designed for 200-240 V ac input
    • Part number: 39M5123
  • UPS-8115 Power Cord (#6) (#9719)
    • Provides power cords for Denmark
    • Nine feet (2.8 m), unshielded, rated 250 V/10 A
    • Attached plug (DK2-5a) designed for 200-240 V ac input
    • Part number: 39M5130
  • UPS-8115 Power Cord (#7) (#9720)
    • Provides power cords for Bangladesh, Burma, Pakistan, South Africa, and Sri Lanka
    • Nine feet (2.8 m), unshielded, rated 250 V/10 A
    • Attached plug (SABS 164) designed for 200-240 V ac input
    • Part number: 39M5144
  • UPS-8115 Power Cord (#8) (#9721)
    • Provides power cords for Switzerland and Liechtenstein
    • Nine feet (2.8 m), unshielded, rated 250 V/10 A
    • Attached plug (1011-S2450 7) designed for 200-240 V ac input
    • Part number: 39M5158
  • UPS-8115 Power Cord (#9) (#9722)
    • Provides power cords for Chile, Ethiopia, Italy, Libya, and Somalia
    • Nine feet (2.8 m), unshielded, rated 250 V/10 A
    • Attached plug (CEI 23-16) designed for 200-240 V ac input
    • Part number: 39M5165
  • UPS-8115 Power Cord (#10) (#9723)
    • Provides power cords for Israel
    • Nine feet (2.8 m), unshielded, rated 250 V/10 A
    • Attached plug (SI 32) designed for 200-240 V ac input
    • Part number: 39M5172
  • UPS-8115 Power Cord (#11) (#9724)
    • Provides power cords for Thailand
    • Nine feet (2.8 m), unshielded, rated 250 V/10 A
    • Attached plug (NEMA 6-15P) designed for 200-240 V ac input
    • Part number: 39M5095
  • UPS-8115 Power Cord (#12) (#9725)
    • Provides power cords for Argentina
    • Nine feet (2.8 m), unshielded, rated 250 V/10 A
    • Attached plug (IRSM 2073) designed for 200-240 V ac input
    • Part number: 39M5068
  • UPS-8115 Power Cord (#13) (#9726)
    • Provides power cords for China
    • Nine feet (2.8 m), unshielded, rated 250 V/6 A
    • Attached plug (GB 2099.1) designed for 200-240 V ac input
    • Part number: 39M5206
  • UPS 8115 Power Cord (#14) (#9727)
    • Provides power cords for Taiwan
    • Nine feet (2.8 m), unshielded, rated 250 V/10 A
    • Attached plug (CNS 10917-3) designed for 200-240 V ac input
    • Part number: 39M5254
Ethernet connection

Every SVC must be connected via Ethernet to a System Storage Productivity Center (SSPC) or master console. Multiple clusters can be managed by a single SSPC or master console. Therefore, at least the first cluster installed in a SAN must include a SSPC (machine type 2805) or master console.

Fibre Channel and Ethernet cabling is not included as part of the hardware provided by IBM. These are the responsibility of the customer. Each SVC Storage Engine requires four fiber optic cables, and another two if the optional 10 Gigabit Ethernet feature (#5711) is ordered. Fiber optic cables may be optionally ordered with the SVC Storage Engines by feature number.

Software requirements

The SVC Storage Engines require that SVC Storage Software V6 (5639-VC6 or 5639-SX1), or later, be ordered at the same time the initial order for the engines of a cluster is placed.

The software can be ordered via the AAS ordering system or the Passport Advantage system. The appropriate hardware feature that indicates the desired fulfillment system (#0017 for Passport Advantage, #0018 for AAS) must be included in the hardware order for the initial engine to be installed. When using or ordering SVC software 5639-VC6 or 5639-SX1, only one software order and license is required for each customer within a country.

For additional details, refer to Software Announcement 211-175, dated May 09, 2011.

Limitations

The maximum number of SVC Storage Engines supported in a SVC cluster is eight.

For limitations of the IBM System Storage SAN Volume Controller Solution imposed by the SVC Storage Software, refer to Software Announcement 211-175, dated May 09, 2011.

Additional limitations and configuration guidelines may apply, as listed under Configuration Requirements and Guidelines at

http://www.ibm.com/storage/support/2145

Planning information

Customer responsibilities

One 220 V power source is required for each UPS feature. Use of separate, independent circuits for the power sources for each node of a node pair is recommended to enhance redundancy within the system.

Redundant AC Power (#8300)

Each of the two power sources are required to be 200-240 V, minimum 5 amp, 50/60 Hz, single phase, and to have IEC320-C19 type outlets.

Each input circuit for the Redundant AC Power switch must be protected by a circuit breaker with maximum rating of 16 amps. Where the Redundant AC Power switch is used to supply a single UPS, a circuit breaker with a minimum rating of 5 amps is required; if two UPSs are being powered then a breaker with a minimum rating of 7 amps is required.

SVC engine removal (#3905)

The SVC engine removal feature should be considered if the engines being ordered will be installed as replacements for currently installed engines. This feature allows the IBM Customer Engineer to physically remove the old engine from its rack.

You are responsible for downloading or obtaining from IBM, and installing designated Machine Code (microcode, basic input/output system code (called BIOS), utility programs, device drivers, and diagnostics delivered with an IBM machine) and other software updates in a timely manner from an IBM Internet Web site or from other electronic media, and following the instructions that IBM provides. You may request IBM to install Machine Code changes; however, you may be charged for that service.

Cable orders

LC-LC fiber optic cables required by the SVC Storage Engines are supplied by the customer. Fiber optic cables can also be ordered by feature number.

Direct customer support

For technical support or assistance, visit the link below and select the appropriate country

http://www.ibm.com/support

Contact your IBM representative for additional assistance.

Security, auditability, and control

This product uses the security and auditability features of the preloaded application software.

The customer is responsible for evaluation, selection, and implementation of security features, administrative procedures, and appropriate controls in application systems and communications facilities.



Back to topBack to top
 
Top rule
Terms and conditions
Bottom rule

Volume orders: Contact your IBM representative.

IBM Global Financing

Yes

Warranty period

One year

An IBM part or feature installed during the initial installation of an IBM machine is subject to a full warranty effective on the date of installation of the machine. An IBM part or feature which replaces a previously installed part or feature assumes the remainder of the warranty period for the replaced part or feature. An IBM part or feature added to a machine without replacing a previously installed part or feature is subject to a full warranty effective on its date of installation. Unless specified otherwise, the warranty period, type of warranty service, and service level of a part or feature is the same as the machine it is installed.

Warranty service

If required, IBM provides repair or exchange service depending on the types of warranty service specified for the machine. IBM will attempt to resolve your problem over the telephone, or electronically via an IBM website. You must follow the problem determination and resolution procedures that IBM specifies. Following problem determination, if IBM determines on-site service is required, scheduling of service will depend upon the time of your call, machine technology and redundancy, and availability of parts.

Service levels are response-time objectives and are not guaranteed. The specified level of warranty service may not be available in all worldwide locations. Additional charges may apply outside IBM's normal service area. Contact your local IBM representative or your reseller for country and location-specific information.

On-site Service

IBM will repair the failing machine at your location and verify its operation. You must provide a suitable working area to allow disassembly and reassembly of the IBM machine. The area must be clean, well lit, and suitable for the purpose.

Service level is:

  • 24 hours per day, 7 days a week, 4 hour average, same day response.

Warranty service upgrades

Usage plan machine

No

IBM hourly service rate classification

Four

When a type of service involves the exchange of a machine part, the replacement may not be new, but will be in good working order.

Field-installable features

Yes

Model conversions

No

Machine installation

Installation is performed by IBM. IBM will install the machine in accordance with the IBM installation procedures for the machine. In the United States, contact IBM at 1-800-IBM-SERV (426-7378). In other countries, contact the local IBM office.

The Machine Installation Guide specifies site preparation, physical requirements and installation (operating) environment, and any cabling included in the installation along with the approximate installation time in hours. Customer requests for installation of items not covered in the installation guide may be performed at IBM's hourly service rate designated for the machine.

Graduated program license charges apply

No

Licensed machine code

IBM Machine Code is licensed for use by a customer on the IBM machine for which it was provided by IBM under the terms and conditions of the IBM License Agreement for Machine Code, to enable the machine to function in accordance with its specifications, and only for the capacity authorized by IBM and acquired by the customer. You can obtain the agreement at

http://www-947.ibm.com/systems/support/machine_warranties/

You may also obtain updated code by contacting your IBM representative.

Educational allowance

A reduced charge is available to qualified education customers. The educational allowance may not be added to any other discount or allowance.

The educational allowance is 15% for the products in this announcement.



Back to topBack to top
 
Top rule
Pricing
Bottom rule

Product charges
 
                               Machine Model  Feat    
Description                    type    number number  

SVC Storage Engine             2145    CG8             
Storage Engine Preload         2145    CG8    0010                      
Storage Engine Preload PA      2145    CG8    0017                      
Storage Engine Preload AAS     2145    CG8    0018                      
Secondary HW cluster           2145    CG8    0019                      
JEMT Indicator                 2145    CG8    0021                      
RFID tag - discretionary       2145    CG8    0203                      
Initial Storage Engine         2145    CG8    3001                      
Additional Storage Engine      2145    CG8    3002                      
SVC engine removal             2145    CG8    3905                         
Solid-State Device Attachment  2145    CG8    4500                         
146 GB Solid-State Device      2145    CG8    4601     
5 m Fiber Optic Cable LC-LC    2145    CG8    5305                         
25 m Fiber Opt Cable LC-LC     2145    CG8    5325                         
IBM 8Gbps LW SFP               2145    CG8    5608                         
10 Gigabit Ethernet Attachment 2145    CG8    5700     
IBM 10GbE Optical SW SFP pair  2145    CG8    5711                                   
UPS - Single Engine            2145    CG8    8115     
Redundant AC Power             2145    CG8    8300                         
 
UPS (#8115) Power Cords:
 
UPS-8115 Power Cord (#1)       2145    CG8    9714                         
  U.S. 250V/10A 6 ft
UPS-8115 Power Cord (#2)       2145    CG8    9715                         
  US/Japan/S.America 9 ft
UPS-8115 Power Cord (#3)       2145    CG8    9716                         
 Eur,Mid-East,Africa
UPS-8115 Power Cord (#4)       2145    CG8    9717                         
 Austral,N.Z.
UPS-8115 Power Cord (#5)       2145    CG8    9718                         
 Eur,Africa
UPS-8115 Power Cord (#6)       2145    CG8    9719                         
 Eur,Den
UPS-8115 Power Cord (#7)       2145    CG8    9720                         
 Pakistan,S.Africa
UPS-8115 Power Cord (#8)       2145    CG8    9721                         
 Switz,Liechtenstein
UPS-8115 Power Cord (#9)       2145    CG8    9722                         
 Chile,Italy,Ethiopia
UPS-8115 Power Cord (#10)      2145    CG8    9723                         
 Israel
UPS-8115 Power Cord (#11)      2145    CG8    9724                         
 Thailand
UPS-8115 Power Cord (#12)      2145    CG8    9725                         
 Argentina
UPS-8115 Power Cord (#13)      2145    CG8    9726                         
 China
UPS-8115 Power Cord (#14)      2145    CG8    9727                         
 Taiwan

 
                              Machine          Field   Plant
                              Model           Install Install MES  CSU
                              Mach/Mod/Feat    Only    Only   Remov  *

Storage Engine Preload        2145/CG8/0010    N       Y      N    N
Storage Engine Preload PA     2145/CG8/0017    N       Y      N    N
Storage Engine Preload AAS    2145/CG8/0018    N       Y      N    N
Secondary HW cluster          2145/CG8/0019    N       Y      N    N
JEMT Indicator                2145/CG8/0021    N       Y      N    N
RFID tag - discretionary      2145/CG8/0203    N       Y      N    N
Initial Storage Engine        2145/CG8/3001    N       Y      N    N
Additional Storage Engine     2145/CG8/3002    N       Y      N    N
SVC engine removal            2145/CG8/3905    N       N      N    N
Solid-State Device Attachment 2145/CG8/4500    N       N      N    N
146GB Solid-State Device      2145/CG8/4601    N       N      N    N
5 m Fiber Optic Cable LC-LC   2145/CG8/5305    N       N      N    Y
25 m Fiber Optic Cable LC-LC  2145/CG8/5325    N       N      N    Y
IBM 8Gbps LW SFP              2145/CG8/5608    N       N      N    Y
10 Gigabit Ethernet Attachment2145/CG8/5700    N       N      N    N
IBM 10GbE Optical SW SFP pair 2145/CG8/5711    N       N      N    Y
UPS - single                  2145/CG8/8115    N       N      N    N
Redundant AC Power            2145/CG8/8300    N       N      N    N
UPS-8115 Power Cord (#1)      2145/CG8/9714    N       Y      N    N
UPS-8115 Power Cord (#2)      2145/CG8/9715    N       Y      N    N
UPS-8115 Power Cord (#3)      2145/CG8/9716    N       Y      N    N
UPS-8115 Power Cord (#4)      2145/CG8/9717    N       Y      N    N
UPS-8115 Power Cord (#5)      2145/CG8/9718    N       Y      N    N
UPS-8115 Power Cord (#6)      2145/CG8/9719    N       Y      N    N
UPS-8115 Power Cord (#7)      2145/CG8/9720    N       Y      N    N
UPS-8115 Power Cord (#8)      2145/CG8/9721    N       Y      N    N
UPS-8115 Power Cord (#9)      2145/CG8/9722    N       Y      N    N
UPS-8115 Power Cord (#10)     2145/CG8/9723    N       Y      N    N
UPS-8115 Power Cord (#11)     2145/CG8/9724    N       Y      N    N
UPS-8115 Power Cord (#12)     2145/CG8/9725    N       Y      N    N
UPS-8115 Power Cord (#13)     2145/CG8/9726    N       Y      N    N
UPS-8115 Power Cord (#14)     2145/CG8/9727    N       Y      N    N

Pricing terms

Prices in the following PDF prices link are suggested list prices on day of announcement for the U.S. only. They are provided for your information only. Dealer prices may vary, and prices may also vary by country. IBM list price does not include tax or shipping and is subject to change without notice.

ENUS-111-083-List_prices_2011_05_09.PDF ENUS-111-083-List_prices_2011_05_09.PDF

ServicePac prices

For ServiceElect (ESA) maintenance service charges, contact IBM Global Services at 888-IBM-4343 (426-4343).

IBM Global Financing

IBM Global Financing offers competitive financing to credit-qualified customers to assist them in acquiring IT solutions. Offerings include financing for IT acquisition, including hardware, software, and services, from both IBM and other manufacturers or vendors. Offerings (for all customer segments: small, medium, and large enterprise), rates, terms, and availability can vary by country. Contact your local IBM Global Financing organization or visit

http://www.ibm.com/financing

IBM Global Financing offerings are provided through IBM Credit LLC in the United States, and other IBM subsidiaries and divisions worldwide to qualified commercial and government customers. Rates are based on a customer's credit rating, financing terms, offering type, equipment type, and options, and may vary by country. Other restrictions may apply. Rates and offerings are subject to change, extension, or withdrawal without notice.

Financing solutions from IBM Global Financing can help you stretch your budget and affordably acquire the new product. But beyond the initial acquisition, our end-to-end approach to IT management can also help keep your technologies current, reduce costs, minimize risk, and preserve your ability to make flexible equipment decisions throughout the entire technology life cycle.



Back to topBack to top
 
Top rule
Order now
Bottom rule

To order, contact the Americas Call Centers or your local IBM representative, or your IBM Business Partner.

To identify your local IBM representative or IBM Business Partner, call 800-IBM-4YOU (426-4968).

Phone:      800-IBM-CALL (426-2255)
Fax:        800-2IBM-FAX (242-6329)
Internet:   callserv@ca.ibm.com
Mail:       IBM Teleweb Customer Support
            ibm.com® Sales Execution Center, Americas North
            3500 Steeles Ave. East, Tower 3/4
            Markham, Ontario
            Canada
            L3R 2Z1

Reference: YE001

The Americas Call Centers, our national direct marketing organization, can add your name to the mailing list for catalogs of IBM products.


Note: Shipments will begin after the planned availability date.
Trademarks

IBM, System Storage, Passport Advantage, PartnerWorld and ibm.com are registered trademarks of IBM Corporation in the United States, other countries, or both.

Intel and Xeon are registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries.

Other company, product, and service names may be trademarks or service marks of others.

Terms of use

IBM products and services which are announced and available in your country can be ordered under the applicable standard agreements, terms, conditions, and prices in effect at the time. IBM reserves the right to modify or withdraw this announcement at any time without notice. This announcement is provided for your information only. Additional terms of use are located at:

http://www.ibm.com/legal/us/en/

For the most current information regarding IBM products, consult your IBM representative or reseller, or visit the IBM worldwide contacts page

http://www.ibm.com/planetwide/us/

Terms of use