Family 8335+04 IBM Power System AC922 optimized Linux workloads

IBM Asia Pacific Sales Manual
Revised:  August 28, 2018.

Table of contents
TOC Link Product life cycle dates TOC Link Technical description
TOC Link Abstract TOC Link Publications
TOC Link Highlights TOC Link Features
TOC Link Description TOC Link Accessories
TOC Link Models TOC Link Supplies

 
Product life cycle dates
Type Model Announced Available Marketing Withdrawn Service Discontinued
8335-GTG 2017/12/052017/12/22 - -

Back to topBack to top
 
Abstract

The IBM Power System AC922 server is co-designed with OpenPOWER Foundation ecosystem members for the demanding needs of deep learning and AI, high-performance analytics, and high-performance computing users. It will be deployed in the most powerful supercomputers on the planet through a partnership between IBM, NVIDIA, and Mellanox, among others.

The Power AC922 server delivers four Tesla V100 with NVLink GPUs supported in two processor sockets, offering 32-core at 2.6 GHz (3.09 GHz turbo) or 40-core at 2.0 GHz (2.87 GHz turbo) POWER9 NVLink 2.0 technology configuration in a 19-inch rack-mount, 2U (EIA units) drawer configuration. All the cores are activated.

The Power AC922 server provides two hot-swap and redundant power supplies (for all GPU configurations) and sixteen DIMM memory slots. Supported memory features are 16 GB (#EM61), 32 GB (#EM63), and 64 GB (#EM64), allowing for a maximum system memory of over 1 TB.

The Power AC922 server also offers:

  • High throughput and performance for high-value Linux workloads such as LAMP, BDA, or industry applications
  • Potentially low acquisition cost through system optimization (industry standard memory, limited configurations, limited I/O and expansion, and industry standard warranty)
  • Multiple I/O options in the system unit, including:
    • Two PCIe x16 4.0 LP slots, CAPI enabled
    • One PCIe x8 4.0 LP slot, CAPI enabled or one PCIe x8x8 shared 4.0 slot, CAPI enabled
    • One PCIe x4 4.0 LP slot
  • Two SFF bays for two HDDs or two SSDs
  • Integrated SATA controller (does not support RAID functionality)
  • Optional Mellanox InfiniBand or high-performance Ethernet
  • One front and one rear USB 3.0 port
  • 19-inch rack-mount 2U configuration
  • Operating systems:
    • Red Hat Enterprise Linux 7.4 for Power LE (IBM POWER9), or later

Model abstract 8335-GTG

The next generation of IBM Power Systems, with POWER9 technology, is built with innovations that deliver high speeds for the AI-Era. Our new Linux scale-out systems embrace acceleration for the next generation of datacenter computing and help provide differentiated performance, scalability, and potentially low acquisition cost. The IBM Power System AC922 for High Performance Computing provides:

  • 2x POWER9 CPUs with next generation NVLINK
  • A differentiated platform for GPU acceleration and superior I/O with PCIe Gen 4 and CAPI 2.0
  • POWER9 with Next generation NVLINK Technology: Only processor with NVLink from CPU to GPU
  • GPUs are connected to CPUs coherently, enabling simpler GPU acceleration and access to system memory for larger model size

Back to topBack to top
 
Highlights

The IBM Power System AC922 (8335-GTG) server is an AI, supercomputing, powerful 2-socket server that offers 32 or 40 fully activated cores and I/O configuration flexibility to help meet accelerated computing needs. The server features are designed for high-performance data analytics and high-performance computing workloads.

The Power System AC922 model offers:

  • Two IBM POWER9 Single Chip Module (SCM) processors that offer high performance with 32 or 40 fully activated cores
  • Up to 1 TB of memory
  • Four PCIe slots and three CAPI enabled for future CAPI-enabled devices (a maximum of three CAPI devices can be used concurrently)
  • Two 2.5-inch SATA drives for a maximum of 4 TB hard disk drive (HDD) or 7.68 TB of solid-state drive (SDD) storage
  • Two integrated USB 3.0 ports
  • Two hot-swap and redundant power supplies: 2200 W 200-240 and 277 V AC
  • 19-inch rack-mount hardware (2U)

Back to topBack to top
 
Description

Summary of standard features for the Power System AC922 server:

  • Power Systems server built with POWER9 processor modules
    • 16-core, 2.6 GHz (3.09 GHz turbo)
    • 20-core, 2.0 GHz (2.87 GHz turbo)
  • High-performance DDR4 memory
    • 256 GB (#EM61 x16), 512 GB (#EM63 x16), or 1.02 TB (#EM64 x16) memory features
  • Storage bays
    • Two SFF 4-bays for two HDDs or two SSDs
    • Two 1 TB 7200 RPM SATA disk drives (#ELD0)
    • Two 2 TB 7200 RPM SATA disk drives (#ES6A)
    • Two 960 GB SATA SSD (#ELU4)
    • Two 1.92 TB SATA SSD (#ELU5)
    • Two 3.84 TB SATA SSD (#ELU6)
  • PCIe Gen4 slots
    • Two PCIe x16 G4 LP slot, CAPI enabled
    • One PCIe x8 G4 LP slot, CAPI enabled
    • One PCIe x4 G4 LP slot
  • Compute Intensive Accelerator
    • Two or four 16 GB SXM2 NVIDIA Tesla V100 GPU with NVLINK Air-Cooled (#EC4J)
  • Integrated:
    • One front USB 3.0 port and one rear USB 3.0 port
  • Two hot-swap redundant power supplies (for all GPU configurations)
  • 19-inch rack-mount hardware (2U)

Power AC922 (8335-GTG) system configuration

The minimum Power AC922 initial order must include: two processor modules, 256 GB of memory, two power supplies, two line cords, rack-mounting hardware, a system software indicator, a rack integrator specify, and a Language Group Specify.

Linux is the operating system. The minimum defined initial order configuration is as follows:

Feature       Description
number
------------- ----------------------------------------------------------
EP0K x 2      16-core 2.6 GHz (3.09 GHz Turbo) POWER9 Processor Module
or
EP0M x 2      20-core 2.0 GHz (2.87 GHz Turbo) POWER9 Processor Module
EM61 x 16     16 GB DIMMs, 2666 MHz, 4 Gb DDR4 DRAM
EC16 x 1      Open Power Abstraction Layer (OPAL)
EC4J x 2      NVIDIA Tesla V100 GPU with NVLINK Air-Cooled (16 GB)
4650 x 1      Rack Indicator -- Not Factory Integrated
EB2X x 2      AC Power Supply, 2200 Watt (200-240V/277V)
2 power cords Select two power cords from supported list. Feature EPAM
              is defaulted. (#EPAM is Power Cord 4.3 m (14-ft), Drawer
              to Wall/IBM PDU (250V/16A))
2147 x 1      Primary OS Linux
EJTY x 1      Rack-mount fixed rail kit
93xx x 1      Language Group Specify (select one from announced
              features)

Note: If a rack is wanted, it must be ordered as an MTM rack on initial system orders. If on the same system order, it will be shipped at the same time in the same shipment, but in separate packing material. IBM does not offer IBM Manufacturing rack integration of the server into the rack before shipping at this time.

Note: 8335-GTG server allows to have 0, 1, or 2 HDD/SSD, there is no mixing of HDD features and no mixing of SSD features.

Processor modules

A minimum of two identical processor modules are required with sixteen processor cores (#EP0K) or twenty processor cores (#EP0M) allowed. All processor cores are activated.

There are no processor activation features used or orderable on the 8335-GTG. All processor cores/"n-ways" are always fully activated.

Mixing of different processor features on the same system is not allowed.

System memory

  • There are 16 memory slots in the server. Each memory slot can hold one DDR4 memory feature. A minimum of 16 memory features is required, filling all the memory slots. With 16 GB DIMMs, 256 GB of memory is required. With 32 GB DIMMs, 512 GB of memory is required. With 64 GB DIMMs, 1.02 TB is required.

Note: Mixing of memory features is not allowed.

DIMM memory features

Feature name        Feature Maximum
                    number  quantity
------------------- ------- --------
16 GB DDR4 2666 MHz EM61    16
32 GB DDR4 2666 MHz EM63    16
64 GB DDR4 2666 MHz EM64    16

The system contains the following adapter slots:

  • Two PCIe x16 G4 HHHL slot, CAPI enabled
  • One PCIe x8 G4HHHL slot, CAPI enabled or one PCIe x8x8 shared 4.0 slot, CAPI enabled
  • One PCIe x4 G4 HHHL slot

Only LP adapters can be placed in LP slots. An x8 adapter can be placed in an x16 slot but an x16 adapter cannot be placed in an x8 slot.

Power supply

  • Two hot-swap and redundant power supplies (for all GPU configurations): 2200 W 200-240V/277V AC (2 x #EB2X)

Power cords

Two power cords are required. Two feature EPAM cords are defaulted. See the feature listing for other options.

Reliability, Availability, and Serviceability

The Power AC922 server brings POWER9 processor and memory RAS functionality into a cloud data center with Open Source Linux technology supplying the operating system and virtualization. The OPAL firmware provides a hypervisor and operating system-independent layer that exploits the error detection and self-healing functions built into the POWER9 processor.

The processor address-paths and data paths, the control logic, state machines, and computational units are protected with parity or error correction codes (ECC). The processor core soft errors or intermittent errors are recovered with processor instruction retry. Unrecoverable errors are reported as machine check (MC) while errors that affect the integrity of data lead to system check-stop.

The Level 1 (L1) data and instruction caches in each processor core are parity protected and data are stored through to L2 immediately. L1 caches have a retry capability for intermittent errors and a cache set delete mechanism for handling solid failures. The L2 and L3 caches in the POWER9 processor are protected with double-bit detect, single-bit correct ECC. In addition, a threshold of correctable errors detected on cache lines can result in the data in the cache lines being purged and the cache lines removed from further access without requiring a reboot. An uncorrectable error detected in these caches can also trigger a purge and delete of cache lines. This does not impact the current operation if the cache lines contained data unmodified from what was stored in system memory.

The memory subsystem has proactive memory scrubbing to help prevent the accumulation of multiple single-bit errors. The ECC scheme can correct the complete failure of any one memory module within an ECC word. After marking the module as unusable, the ECC logic can still correct single symbol (two adjacent bit) errors. An uncorrectable error of data of any layer of cache up to the main memory is marked to prevent usage of fault data. The processor's memory controller has retry capabilities for certain fetch and store faults.

Special Uncorrectable Error handling

Special Uncorrectable Error (SUE) handling prevents an uncorrectable error in memory or cache from immediately causing the system to terminate. Rather, the system tags the data and determines whether it will ever be used again. If the error is irrelevant, it will not force a checkstop. If the data is used, termination may be limited to the program/kernel or hypervisor owning the data; or freeze of the I/O adapters controlled by an I/O hub controller if data would be transferred to an I/O device.

Thermal management, current/voltage monitoring

The On Chip Controller (OCC) monitors various temperature sensors in the processor module, memory modules, and environmental temperature sensors and steers the throttling of processor cores and memory channels should the temperature rise over thresholds defined by the design. The power supplies have their own independent thermal sensors and monitoring.

Power supplies and voltage regulator modules monitor over-voltage, under-voltage, and over-current conditions. They report into a power good tree that is monitored by the Service Processor.

PCI extended error handling

PCI extended error handling (EEH)-enabled adapters respond to a special data packet generated from the affected PCI slot hardware by calling system firmware, which will examine the affected bus, allow the device driver to reset it, and continue without a system reboot. For Linux, EEH support extends to the majority of frequently used devices, although some third-party PCI devices may not provide native EEH support.

Graphics processing unit (GPU) acceleration

GPUs are attached with second-generation NVLink to the system power processors and provide cache coherence capabilities. The GPUs should be run in "compute mode," which enables Single Error Correction and Double Error Detection (SECDEC) Error Correction Code (ECC) for the GPU Memory, SM register file, L1 cache, and L2 cache to improve data integrity for GPU-accelerated workloads.

Chassis policy after input power loss and autorestart after system-check-stop The boot parameter "chassis policy" controls whether the server returns to the previous state or powers up axiomatically after an input power loss. The system automatically reboots after a system-check-stop, and it is up to the system management software to decide whether to use the server with potentially fewer resources.

Serviceability

The server is designed for system install and setup, feature install and remove, proactive maintenance, and corrective repair performed by the client: Warranty Service Upgrades are offered for an On Site Repair (OSR) by an IBM System Services Representative (SSR) or an authorized warranty service provider.

IBM Knowledge Center provides up-to-date documentation to effectively service the system with:

  • Quick Install Guide
  • User's Guide
  • Troubleshooting Guide
  • Boot Configuration Guide

The documentation can be downloaded in PDF format or used online with an internet connection.

Service Processor

The Service Processor supports the Intelligent Platform Management Interface (IPMI 2.0) and Data Center Management Interface (DCMI 1.5) and Simple Network Management Protocol (SNMP V2 and V3) for system monitoring and management. The Service Processor provides platform system functions such as power on/off, power sequencing, power fault monitoring, power reporting, fan/thermal control, fault monitoring, VPD inventory collection, Serial over LAN (SOL), Service Indicator LED management, code update, and event reporting through system event logs (SEL).

All SELs can be retrieved either directly from the Service Processor or from the host operating system (Linux). The Service Processor monitors the operation of the firmware during the boot process and also monitors the hypervisor for termination. The firmware code update is supported through the Service Processor and IPMI interface. The firmware image can be updated or flashed regardless of its current state.

Service interface

The service interface enables the client and the support personnel to communicate with the service support applications in a server by connecting directly or remotely through a web browser or command-line interface. It provides access to various service applications and available actions. The service interface enables client and support personnel to manage system resources, inventory, and service information in an efficient and effective way.

Different service interfaces are used, depending on the state of the system and its operating environment. The primary service interfaces are:

  • Service processor: Ethernet Service Network with IPMI version 2.0, systems management GUI through web browser
  • Service indicator LEDs: System attention and system identification (front and back)
  • Host operating system: Command-line interface

The primary service applications are:

  • System event logs (SEL)
  • Operating system event logs
  • Sensor status GUI LEDs for Problem Determination (PD) when next to the system, locally

Concurrent maintenance

The following components can be replaced without powering off the server:

  • Hard drives
  • Fans

Error handling and reporting

In the event of a system hardware failure or environmentally induced failure, the system error capture capability systematically analyzes the hardware error signature to help determine the cause of failure. The processor and memory recoverable errors are handled through Processor Runtime Diagnostics (PRD) in the OPAL layer and generate a system event log (SEL). An extended SEL (eSEL) is associated with each SEL. It contains additional First Failure Data Capture (FFDC) information for use by the support structure.

For system check-stop errors, the On Chip Controller (OCC) collects Failure Information Register (FIR) data and saves it in nonvolatile memory. PRD analyzes the data upon reboot and creates a SEL and an eSEL. The host Linux operating system can monitor the SELs on the service processor through the IPMI tool. Hardware and firmware failures are recorded in the SELs and can be retrieved through the IPMI interface. The system has the ability to report errors associated with PCIe adapters/devices through the host operating system.

Warranty and spare parts

The system comes with a three-year warranty on parts. The replacement parts can be ordered through the Advanced Part Exchange Warranty Service.

Accessibility by people with disabilities

A US Section 508 Voluntary Product Accessibility Template (VPAT) containing details on accessibility compliance can be found on the Product accessibility information website.

Section 508 of the US Rehabilitation Act

IBM Power System AC922 (8335-GTG) is capable as of December 22, 2017, when used in accordance with IBM's associated documentation, of satisfying the applicable requirements of Section 508 of the Rehabilitation Act, provided that any assistive technology used with the product properly interoperates with it. A US Section 508 Voluntary Product Accessibility Template (VPAT) can be found on the Product accessibility information website.
Back to topBack to top
 

Models

Model summary matrix

Model Processor Speed Memory
GTG 16-, 20-core 2.6 GHz (3.09 GHz turbo) to 2.0 GHz (2.87 GHz turbo) 256 GB to over 1 TB

Customer setup (CSU)

Yes.

Devices supported

IBM 7226-1U3 Multi-Media Storage Enclosure.

  • LTO Ultrium Fiber Channel (FC) Tape Drive feature numbers
    • #8348 LTO Ultrium 6 FC tape drive. Capacity up to 6.25 TB
    • #8446 LTO Ultrium 7 FC tape drive. Capacity up to 15 TB
    • #8546 LTO Ultrium 8 FC tape drive. Capacity up to 30 TB
    • DVD-RAM USB 3.0 drive feature #5757
    • RDX (USB 3.0) Removable hard drives. Drive capacity: 500 GB, 1 TB, 2 TB

Model conversions

Not available.
Back to topBack to top
 

Technical description
TOC Link Physical specifications TOC Link Operating environment TOC Link Limitations
TOC Link Hardware requirements TOC Link Software requirements


Physical specifications

  • Width: 444.5 mm (17.5 in.)
  • Depth: 850.9 mm (33.5 in.)
  • Height: 88.9 mm (3.5 in.)
  • Weight: 30 kg (66 lb)

To assure installability and serviceability in non-IBM industry-standard racks, review the installation planning information for any product-specific installation requirements.

Operating environment

For some standards and guidelines for operating environment, see the ASHRAE-A2 website.

Limitations

  • The integrated system ports are supported for modem and asynchronous terminal connections with Linux. Any other application using serial ports requires a serial port adapter to be installed in a PCI slot. The integrated system ports do not support HACMP configurations.
  • The VGA port does not support cable lengths that exceed 3 meters.

Hardware requirements

Not applicable.

Software requirements

Red Hat Enterprise Linux 7.4 for Power LE (POWER9), or later
Back to topBack to top
 

Publications

IBM Power Systems hardware documentation provides clients with the following topical information:

  • Licenses, notices, safety, and warranty information
  • Planning for the system
  • Installing and configuring the system
  • Troubleshooting, service, and support
  • Installing operating systems
  • Glossary

Product documentation is also available on DVD (SK5T-7087).

The following information is shipped with the 8335-GTG server:

  • Supporting information for IBM
  • IBM Power System AC922 (8335-GTG) (GI11-9916)
  • Warranty GI11-4340
  • License Agreement for Machine Code Z125-5468

You can access the product documentation at IBM Knowledge Center .

IBM Knowledge Center provides you with a single information center where you can access product documentation for IBM systems hardware, operating systems, and server software. Through a consistent framework, you can efficiently find information and personalize your access.

To access the IBM Publications Center Portal, go to the IBM Publications Center website.

The Publications Center is a worldwide central repository for IBM product publications and marketing material with a catalog of 70,000 items. Extensive search facilities are provided. A large number of publications are available online in various file formats, which can currently be downloaded.
Back to topBack to top
 

Features
TOC Link Features - No charge TOC Link Features - Chargeable TOC Link Feature availability matrix
TOC Link Feature descriptions


Features - No charge

  • NONE

Features - Chargeable

Special Features - Initial Orders

  • Administrative
    • (#ECL0) -Power ACP solution specify
    • (#ECP0) -Cloud Private Solution
    • (#ESC5) -S&H-a
  • Languages
    • (#9300) -Language Group Specify - US English
    • (#9700) -Language Group Specify - Dutch
    • (#9703) -Language Group Specify - French
    • (#9704) -Language Group Specify - German
    • (#9705) -Language Group Specify - Polish
    • (#9706) -Language Group Specify - Norwegian
    • (#9707) -Language Group Specify - Portuguese
    • (#9708) -Language Group Specify - Spanish
    • (#9711) -Language Group Specify - Italian
    • (#9712) -Language Group Specify - Canadian French
    • (#9714) -Language Group Specify - Japanese
    • (#9715) -Language Group Specify - Traditional Chinese (Taiwan)
    • (#9716) -Language Group Specify - Korean
    • (#9718) -Language Group Specify - Turkish
    • (#9719) -Language Group Specify - Hungarian
    • (#9720) -Language Group Specify - Slovakian
    • (#9721) -Language Group Specify - Russian
    • (#9722) -Language Group Specify - Simplified Chinese (PRC)
    • (#9724) -Language Group Specify - Czech
    • (#9725) -Language Group Specify -- Romanian
    • (#9726) -Language Group Specify - Croatian
    • (#9727) -Language Group Specify -- Slovenian
    • (#9728) -Language Group Specify - Brazilian Portuguese
    • (#9729) -Language Group Specify - Thai
  • Miscellaneous
    • (#5000) -Software Preload Required
    • (#8143) -Linux Software Preinstall
    • (#8144) -Linux Software Preinstall (Business Partners)
    • (#9461) -Month Indicator
    • (#9462) -Day Indicator
    • (#9463) -Hour Indicator
    • (#9464) -Minute Indicator
    • (#9465) -Qty Indicator
    • (#9466) -Countable Member Indicator
  • Packaging
    • (#ERB0) -Bulk Packaging Request ID
    • (#ERB1) -Bulk Packaging ID #1
    • (#ERB2) -Bulk Packaging ID #2
    • (#ERB3) -Bulk Packaging ID #3
    • (#ERB4) -Bulk Packaging ID #4
    • (#ERB5) -Bulk Packaging ID #5
    • (#ERB6) -Bulk Packaging ID #6
    • (#ERB7) -Bulk Packaging ID #7
    • (#ERB8) -Bulk Packaging ID #8
    • (#ERB9) -Bulk Packaging ID #9
    • (#ERBA) -Bulk Packaging ID #10
    • (#ERBB) -Bulk Packaging ID #11
    • (#ERBC) -Bulk Packaging ID #12
    • (#ERBD) -Bulk Packaging ID #13
    • (#ERBE) -Bulk Packaging ID #14
    • (#ERBF) -Bulk Packaging ID #15
    • (#ERBG) -Bulk Packaging ID #16
    • (#ERBH) -Bulk Packaging ID #17
    • (#ERBJ) -Bulk Packaging ID #18
    • (#ERBK) -Bulk Packaging ID #19
    • (#ERBL) -Bulk Packaging ID #20
    • (#ERBZ) -No Bulk Packaging Specify
  • Power
    • (#EB2X) -AC Power Supply - 2200 WATT (200-240V/277V)
  • Processor
    • (#EP0K) -16-core 2.60 GHz (3.09 GHz Turbo) POWER9
    • (#EP0M) -20-core 2.0 GHz (2.87 GHz Turbo) POWER9
  • Services
    • (#ERF1) -RFID Tags for Servers, Compute Nodes, Chassis, Racks, and HMCs
  • Specify Codes
    • (#4650) -Rack Indicator-Not Factory Integrated
    • (#4651) -Rack Indicator, Rack #1
    • (#4652) -Rack Indicator, Rack #2
    • (#4653) -Rack Indicator, Rack #3
    • (#4654) -Rack Indicator, Rack #4
    • (#4655) -Rack Indicator, Rack #5
    • (#4656) -Rack Indicator, Rack #6
    • (#4657) -Rack Indicator, Rack #7
    • (#4658) -Rack Indicator, Rack #8
    • (#4659) -Rack Indicator, Rack #9
    • (#4660) -Rack Indicator, Rack #10
    • (#4661) -Rack Indicator, Rack #11
    • (#4662) -Rack Indicator, Rack #12
    • (#4663) -Rack Indicator, Rack #13
    • (#4664) -Rack Indicator, Rack #14
    • (#4665) -Rack Indicator, Rack #15
    • (#4666) -Rack Indicator, Rack #16
    • (#9442) -New Red Hat License Core Counter
    • (#9445) -Other Linux License Core Counter
    • (#9446) -3rd Party Linux License Core Counter
    • (#9449) -Other License Core Counter
  • Virtualization Engine
    • (#EC16) -Open Power non-virtualized configuration

Special Features - Plant and/or Field Installable

  • Adapters
    • (#EC3L) -PCIe3 LP 2-port 100GbE (NIC& RoCE) QSFP28 Adapter x16
    • (#EC4J) -NVIDIA Tesla V100 GPU with NVLINK Air-Cooled (16 GB)
    • (#EC5A) -PCIe3 LP 1.6 TB SSD NVMe adapter
    • (#EC62) -PCIe4 LP 1-port 100Gb EDR IB CAPI adapter
    • (#EC64) -PCIe4 LP 2-port 100Gb EDR IB CAPI adapter
    • (#EL3Z) -PCIe2 LP 2-port 10/1GbE BaseT RJ45 Adapter
    • (#EL43) -PCIe3 LP 2-port 16Gb Fibre Channel Adapter
    • (#EL4M) -PCIe2 LP 4-port 1GbE Adapter
    • (#EN0T) -PCIe2 LP 4-Port (10Gb+1GbE) SR+RJ45 Adapter
    • (#EN0V) -PCIe2 LP 4-port (10Gb+1GbE) Copper SFP+RJ45 Adapter
  • Administrative
    • (#ESC0) -S&H - No Charge
  • Cable
    • (#4256) -Extender Cable - USB Keyboards, 1.8M
    • (#EB27) -QSFP+ 40GBase-SR Transceiver
    • (#EB2B) -1m (3.3-ft), IBM Passive QSFP+ to QSFP+ Cable (DAC)
    • (#EB2H) -3m (9.8-ft), IBM Passive QSFP+ to QSFP+ Cable (DAC)
    • (#EB2J) -10m (30.3-ft), IBM Passive QSFP+ MTP Optical Cable
    • (#EB2K) -30m (90.3-ft), IBM Passive QSFP+ MTP Optical Cable
    • (#EB4J) -0.5m SFP28/25GbE copper Cable
    • (#EB4K) -1.0m SFP28/25GbE copper Cable
    • (#EB4L) -1.5m SFP28/25GbE copper Cable
    • (#EB4M) -2.0m SFP28/25GbE copper Cable
    • (#EB4P) -2.0m QSFP28/100GbE copper split Cable to SFP28 4x25GbE
    • (#EB50) -0.5m EDR IB Copper Cable QSFP28
    • (#EB52) -2.0m EDR IB Copper Cable QSFP28
    • (#EB54) -1.5m EDR IB Copper Cable QSFP28
    • (#EB59) -100Gb Optical Transceiver QSFP28
    • (#EB5A) -3m EDR IB Optical Cable QSFP28
    • (#EB5B) -5m EDR IB Optical Cable QSFP28
    • (#EB5C) -10m EDR IB Optical Cable QSFP28
    • (#EB5D) -15m EDR IB Optical Cable QSFP28
    • (#EB5E) -20m EDR IB Optical Cable QSFP28
    • (#EB5F) -30m EDR IB Optical Cable QSFP28
    • (#EB5G) -50m EDR IB Optical Cable QSFP28
    • (#EB5H) -100m EDR IB Optical Cable QSFP28
    • (#EB5J) -0.5m 100GbE Copper Cable QSFP28
    • (#EB5K) -1.0m 100GbE Copper Cable QSFP28
    • (#EB5L) -1.5m 100GbE Copper Cable QSFP28
    • (#EB5M) -2.0m 100GbE Copper Cable QSFP28
    • (#EB5N) -25m EDR IB Optical Cable QSFP28
    • (#EB5R) -3m 100GbE Optical Cable QSFP28 (AOC)
    • (#EB5S) -5m 100GbE Optical Cable QSFP28 (AOC)
    • (#EB5T) -10m 100GbE Optical Cable QSFP28 (AOC)
    • (#EB5U) -15m 100GbE Optical Cable QSFP28 (AOC)
    • (#EB5V) -20m 100GbE Optical Cable QSFP28 (AOC)
    • (#EB5W) -30m 100GbE Optical Cable QSFP28 (AOC)
    • (#EB5X) -50m 100GbE Optical Cable QSFP28 (AOC)
    • (#EB5Y) -100m 100GbE Optical Cable QSFP28 (AOC)
    • (#ECBN) -5m (16.4-ft), IBM Passive QSFP+ to QSFP+ Cable (DAC)
    • (#ECW0) -Optical Wrap Plug
    • (#EN01) -1m (3.3-ft), 10Gb E'Net Cable SFP+ Act Twinax Copper
    • (#EN02) -3m (9.8-ft), 10Gb E'Net Cable SFP+ Act Twinax Copper
    • (#EN03) -5m (16.4-ft), 10Gb E'Net Cable SFP+ Act Twinax Copper
  • Disk
    • (#ELD0) -1 TB 7.2k RPM 5xx SATA SFF-4 Disk Drive
    • (#ES6A) -2 TB 7.2k RPM 5xx SATA SFF-4 Disk Drive
  • Linecords
    • (#6489) -4.3m (14-Ft) 3PH/24A 380-415V Power Cord
    • (#6491) -4.3m (14-Ft) 1PH/63A 200-240V Power Cord
    • (#6492) -4.3m (14-Ft) 1PH/48-60A 200-240V Power Cord
    • (#6653) -4.3m (14-Ft) 3PH/16A 380-415V Power Cord
    • (#6654) -4.3m (14-Ft) 1PH/24-30A Pwr Cord
    • (#6655) -4.3m (14-Ft) 1PH/24-30A WR Pwr Cord
    • (#6656) -4.3m (14-Ft) 1PH/24A Power Cord
    • (#6657) -4.3m (14-Ft) 1PH/32A Power Cord
    • (#6658) -4.3m (14-Ft) 1PH/24A Pwr Cd-Korea
    • (#6667) -4.3m (14-Ft) 3PH/32A 380-415V Power Cord-Australia
    • (#EPAJ) -Power Cord 2m (6.56-foot), Drawer to IBM PDU, 250V/16A
    • (#EPAL) -Power Cord 2.8m (9.18-foot), Drawer to IBM PDU, 250V/16A
    • (#EPAM) -Power Cord 4.3m (14.10-foot), Drawer to IBM PDU, 250V/ 16A
  • Media Devices
    • (#EUA5) -Standalone USB DVD drive w/cable
  • Memory
    • (#EM61) -16 GB DDR4 2666 RDIMM
    • (#EM63) -32 GB DDR4 2666 RDIMM
  • Miscellaneous
    • (#2147) -Primary OS - Linux
    • (#ECSF) -Custom Service Specify, Montpellier, France
    • (#EHL9) -Marketing Specify - NVIDIA GPU
  • Power
    • (#EPTJ) -High Function 9xC19 PDU: Switched, Monitoring
    • (#EPTL) -High Function 9xC19 PDU 3-Phase: Switched, Monitoring
  • Rack Related
    • (#EJTX) -Rack-mount Fixed Rail Kit
    • (#EJTY) -Rack-mount Slide Rail Kit
    • (#EPTH) -Horizontal PDU Mounting Hardware
  • Services
    • (#0010) -One CSC Billing Unit
    • (#0011) -Ten CSC Billing Units
  • Solid State Drive
    • (#ELU4) -960 GB 2.5-inch SATA/SSD Disk Drive
    • (#ELU5) -1.92 TB 2.5-inch SATA/SSD Disk Drive
    • (#ELU6) -3.84 TB 2.5-inch SATA/SSD Disk Drive

Feature availability matrix

The following feature availability matrix for MT 8335 uses the letter "A" to indicate features that are available and orderable on the specified models. "S" indicates a feature that is supported on the new model during a model conversion; these features will work on the new model, but additional quantities of these features cannot be ordered on the new model; they can only be removed. "N" indicates that the feature is not supported on the new model and must be removed during the model conversion. As additional features are announced, supported, or withdrawn, this list will be updated. Please check with your Marketing Representative for additional information.

         G  A = AVAILABLE  S = SUPPORTED
         T  N = NOT SUPPORTED, MUST BE REMOVED
         G 
           
FEAT/PN            DESCRIPTION
-------- - ----------------------------------------------------------
0010     A  One CSC Billing Unit
0011     A  Ten CSC Billing Units
2147     A  Primary OS - Linux
4256     A  Extender Cable - USB Keyboards, 1.8M
4650     A  Rack Indicator - Not Factory Integrated
4651     A  Rack Indicator, Rack #1
4652     A  Rack Indicator, Rack #2
4653     A  Rack Indicator, Rack #3
4654     A  Rack Indicator, Rack #4
4655     A  Rack Indicator, Rack #5
4656     A  Rack Indicator, Rack #6
4657     A  Rack Indicator, Rack #7
4658     A  Rack Indicator, Rack #8
4659     A  Rack Indicator, Rack #9
4660     A  Rack Indicator, Rack #10
4661     A  Rack Indicator, Rack #11
4662     A  Rack Indicator, Rack #12
4663     A  Rack Indicator, Rack #13
4664     A  Rack Indicator, Rack #14
4665     A  Rack Indicator, Rack #15
4666     A  Rack Indicator, Rack #16
5000     A  Software Preload Required
6489     A  4.3m (14-Ft) 3PH/24A 380-415V Power Cord
6491     A  4.3m (14-Ft) 1PH/63A 200-240V Power Cord
6492     A  4.3m (14-Ft) 1PH/48-60A 200-240V Power Cord
6653     A  4.3m (14-Ft) 3PH/16A 380-415V Power Cord
6654     A  4.3m (14-Ft) 1PH/24-30A Pwr Cord
6655     A  4.3m (14-Ft) 1PH/24-30A WR Pwr Cord
6656     A  4.3m (14-Ft) 1PH/24A Power Cord
6657     A  4.3m (14-Ft) 1PH/32A Power Cord
6658     A  4.3m (14-Ft) 1PH/24A Pwr Cd-Korea
6667     A  4.3m (14-Ft) 3PH/32A 380-415V Power Cord-Australia
8143     A  Linux Software Preinstall
8144     A  Linux Software Preinstall (Business Partners)
9300     A  Language Group Specify - US English
9442     A  New Red Hat License Core Counter
9445     A  Other Linux License Core Counter
9446     A  3rd Party Linux License Core Counter
9449     A  Other License Core Counter
9461     A  Month Indicator
9462     A  Day Indicator
9463     A  Hour Indicator
9464     A  Minute Indicator
9465     A  Qty Indicator
9466     A  Countable Member Indicator
9700     A  Language Group Specify - Dutch
9703     A  Language Group Specify - French
9704     A  Language Group Specify - German
9705     A  Language Group Specify - Polish
9706     A  Language Group Specify - Norwegian
9707     A  Language Group Specify - Portuguese
9708     A  Language Group Specify - Spanish
9711     A  Language Group Specify - Italian
9712     A  Language Group Specify - Canadian French
9714     A  Language Group Specify - Japanese
9715     A  Language Group Specify - Traditional Chinese (Taiwan)
9716     A  Language Group Specify - Korean
9718     A  Language Group Specify - Turkish
9719     A  Language Group Specify - Hungarian
9720     A  Language Group Specify - Slovakian
9721     A  Language Group Specify - Russian
9722     A  Language Group Specify - Simplified Chinese (PRC)
9724     A  Language Group Specify - Czech
9725     A  Language Group Specify -- Romanian
9726     A  Language Group Specify - Croatian
9727     A  Language Group Specify -- Slovenian
9728     A  Language Group Specify - Brazilian Portuguese
9729     A  Language Group Specify - Thai
EB27     A  QSFP+ 40GBase-SR Transceiver
EB2B     A  1m (3.3-ft), IBM Passive QSFP+ to QSFP+ Cable (DAC)
EB2H     A  3m (9.8-ft), IBM Passive QSFP+ to QSFP+ Cable (DAC)
EB2J     A  10m (30.3-ft), IBM Passive QSFP+ MTP Optical Cable
EB2K     A  30m (90.3-ft), IBM Passive QSFP+ MTP Optical Cable
EB2X     A  AC Power Supply - 2200 WATT (200-240V/277V)
EB4J     A  0.5m SFP28/25GbE copper Cable
EB4K     A  1.0m SFP28/25GbE copper Cable
EB4L     A  1.5m SFP28/25GbE copper Cable
EB4M     A  2.0m SFP28/25GbE copper Cable
EB4P     A  2.0m QSFP28/100GbE copper split Cable to SFP28 4x25GbE
EB50     A  0.5m EDR IB Copper Cable QSFP28
EB51     A  1.0m EDR IB Copper Cable QSFP28
EB52     A  2.0m EDR IB Copper Cable QSFP28
EB54     A  1.5m EDR IB Copper Cable QSFP28
EB59     A  100Gb Optical Transceiver QSFP28
EB5A     A  3m EDR IB Optical Cable QSFP28
EB5B     A  5m EDR IB Optical Cable QSFP28
EB5C     A  10m EDR IB Optical Cable QSFP28
EB5D     A  15m EDR IB Optical Cable QSFP28
EB5E     A  20m EDR IB Optical Cable QSFP28
EB5F     A  30m EDR IB Optical Cable QSFP28
EB5G     A  50m EDR IB Optical Cable QSFP28
EB5H     A  100m EDR IB Optical Cable QSFP28
EB5J     A  0.5m 100GbE Copper Cable QSFP28
EB5K     A  1.0m 100GbE Copper Cable QSFP28
EB5L     A  1.5m 100GbE Copper Cable QSFP28
EB5M     A  2.0m 100GbE Copper Cable QSFP28
EB5N     A  25m EDR IB Optical Cable QSFP28
EB5R     A  3m 100GbE Optical Cable QSFP28 (AOC)
EB5S     A  5m 100GbE Optical Cable QSFP28 (AOC)
EB5T     A  10m 100GbE Optical Cable QSFP28 (AOC)
EB5U     A  15m 100GbE Optical Cable QSFP28 (AOC)
EB5V     A  20m 100GbE Optical Cable QSFP28 (AOC)
EB5W     A  30m 100GbE Optical Cable QSFP28 (AOC)
EB5X     A  50m 100GbE Optical Cable QSFP28 (AOC)
EB5Y     A  100m 100GbE Optical Cable QSFP28 (AOC)
EC16     A  Open Power non-virtualized configuration
EC3L     A  PCIe3 LP 2-port 100GbE (NIC& RoCE) QSFP28 Adapter x16
EC4J     A  NVIDIA Tesla V100 GPU with NVLINK Air-Cooled (16 GB)
EC5A     A  PCIe3 LP 1.6 TB SSD NVMe adapter
EC62     A  PCIe4 LP 1-port 100Gb EDR IB CAPI adapter
EC64     A  PCIe4 LP 2-port 100Gb EDR IB CAPI adapter
ECBN     A  5m (16.4-ft), IBM Passive QSFP+ to QSFP+ Cable (DAC)
ECL0     A  Power ACP solution specify
ECP0     A  Cloud Private Solution
ECSF     A  Custom Service Specify, Montpellier, France
ECW0     A  Optical Wrap Plug
EHL9     A  Marketing Specify - NVIDIA GPU
EJTX     A  Rack-mount Fixed Rail Kit
EJTY     A  Rack-mount Slide Rail Kit
EL3Z     A  PCIe2 LP 2-port 10/1GbE BaseT RJ45 Adapter
EL43     A  PCIe3 LP 2-port 16Gb Fibre Channel Adapter
EL4M     A  PCIe2 LP 4-port 1GbE Adapter
ELD0     A  1 TB 7.2k RPM 5xx SATA SFF-4 Disk Drive
ELU4     A  960 GB 2.5-inch SATA/SSD Disk Drive
ELU5     A  1.92 TB 2.5-inch SATA/SSD Disk Drive
ELU6     A  3.84 TB 2.5-inch SATA/SSD Disk Drive
EM61     A  16 GB DDR4 2666 RDIMM
EM63     A  32 GB DDR4 2666 RDIMM
EM64     A  64 GB DDR4 2666 RDIMM
EN01     A  1m (3.3-ft), 10Gb E'Net Cable SFP+ Act Twinax Copper
EN02     A  3m (9.8-ft), 10Gb E'Net Cable SFP+ Act Twinax Copper
EN03     A  5m (16.4-ft), 10Gb E'Net Cable SFP+ Act Twinax Copper
EN0T     A  PCIe2 LP 4-Port (10Gb+1GbE) SR+RJ45 Adapter
EN0V     A  PCIe2 LP 4-port (10Gb+1GbE) Copper SFP+RJ45 Adapter
EP0K     A  16-core 2.60 GHz (3.09 GHz Turbo) POWER9
EP0M     A  20-core 2.0 GHz (2.87 GHz Turbo) POWER9
EPAJ     A  Power Cord 2m (6.56-foot), Drawer to IBM PDU, 250V/16A
EPAL     A  Power Cord 2.8m (9.18-foot), Drawer to IBM PDU, 250V/16A
EPAM     A  Power Cord 4.3m (14.10-foot), Drawer to IBM PDU, 250V/16A
EPTH     A  Horizontal PDU Mounting Hardware
EPTJ     A  High Function 9xC19 PDU: Switched, Monitoring
EPTL     A  High Function 9xC19 PDU 3-Phase: Switched, Monitoring
ERB0     A  Bulk Packaging Request ID
ERB1     A  Bulk Packaging ID #1
ERB2     A  Bulk Packaging ID #2
ERB3     A  Bulk Packaging ID #3
ERB4     A  Bulk Packaging ID #4
ERB5     A  Bulk Packaging ID #5
ERB6     A  Bulk Packaging ID #6
ERB7     A  Bulk Packaging ID #7
ERB8     A  Bulk Packaging ID #8
ERB9     A  Bulk Packaging ID #9
ERBA     A  Bulk Packaging ID #10
ERBB     A  Bulk Packaging ID #11
ERBC     A  Bulk Packaging ID #12
ERBD     A  Bulk Packaging ID #13
ERBE     A  Bulk Packaging ID #14
ERBF     A  Bulk Packaging ID #15
ERBG     A  Bulk Packaging ID #16
ERBH     A  Bulk Packaging ID #17
ERBJ     A  Bulk Packaging ID #18
ERBK     A  Bulk Packaging ID #19
ERBL     A  Bulk Packaging ID #20
ERBZ     A  No Bulk Packaging Specify
ERF1     A  RFID Tags for Servers, Compute Nodes, Chassis, Racks, and
           HMCs
ES6A     A  2 TB 7.2k RPM 5xx SATA SFF-4 Disk Drive
ESC0     A  S&H - No Charge
ESC5     A  S&H-a
EUA5     A  Standalone USB DVD drive w/cable

Feature descriptions

The following is a list of all feature codes in numeric order for the IBM Power Systems 8335 machine type.

Attributes, as defined in the following feature descriptions, state the interaction of requirements among features.

Minimums and maximums are the absolute limits for a single feature without regard to interaction with other features. The maximum valid quantity for MES orders may be different than for initial orders. The maximums listed below refer to the largest quantity of these two possibilities.

The order type defines if a feature is orderable only on initial orders, only on MES orders, on both initial and MES orders, or if a feature is supported on a model due to a model conversion. Supported features cannot be ordered on the converted model, only left on or removed from the converted model.

(#0010) - One CSC Billing Unit

One Billing Unit used by the Customer Solution Center.

  • Attributes provided: One CSC Billing Unit
  • Attributes required: None
  • For 8335-GTG: (#0010)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: Does not apply
(#0011) - Ten CSC Billing Units

Ten Billing Units used by the Customer Solutions Center.

  • Attributes provided: Ten CSC Billing Units
  • Attributes required: None
  • For 8335-GTG: (#0011)
    • Minimum required: 0
    • Maximum allowed: 100 (Initial order maximum: 100)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: Does not apply
(#2147) - Primary OS - Linux

Indicates clients intend to use the Linux operating system on the primary system partition. This feature is used as a Manufacturing Routing indicator and does not deliver parts, software or services.

  • Attributes provided: None
  • Attributes required: Indicates clients intend to use the Linux operating system on the primary system partition.
  • For 8335-GTG: (#2147)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 1)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#4256) - Extender Cable - USB Keyboards, 1.8M

This feature provides a 1.8M extension cable for use with USB keyboards.

  • Attributes provided: 1.8M Extension Cable
  • Attributes required: USB Keyboard
  • For 8335-GTG: (#4256)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: No
(#4650) - Rack Indicator- Not Factory Integrated

This indicator is used to specify that the rack mountable device in this initial order should not be merged into a rack within IBM Manufacturing.

Note: This "no additional charge" feature will be placed on an initial order for a rack mountable device by the Configuration Tool when the order does not include a 19" Rack.

A rack integration indicator is required on all 19" Rack mountable device initial orders. One feature code from the group 4650 must be listed on the order.

  • Attributes provided: System will not be shipped in a rack.
  • Attributes required: None
  • For 8335-GTG: (#4650)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#4651) - Rack Indicator, Rack #1

When added to an initial rack order, this indicator is used to specify the first rack for a multi rack order, or the only rack for a single rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #1.

Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack Integration/ Rack Specify
  • Attributes required: Rack
  • For 8335-GTG: (#4651)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#4652) - Rack Indicator, Rack #2

When added to an initial rack order, this indicator is used to specify the second rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #2 of a multi rack order.

Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack Integration/Rack specify
  • Attributes required: Rack
  • For 8335-GTG: (#4652)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#4653) - Rack Indicator, Rack #3

When added to an initial rack order, this indicator is used to specify the third rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #3 of a multi rack order.

Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 8335-GTG: (#4653)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#4654) - Rack Indicator, Rack #4

When added to an initial rack order, this indicator is used to specify the fourth rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #4 of a multi rack order.

Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 8335-GTG: (#4654)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#4655) - Rack Indicator, Rack #5

When added to an initial rack order, this indicator is used to specify the fifth rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #5 of a multi rack order.

Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 8335-GTG: (#4655)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#4656) - Rack Indicator, Rack #6

When added to an initial rack order, this indicator is used to specify the sixth rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #6 of a multi rack order.

Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 8335-GTG: (#4656)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#4657) - Rack Indicator, Rack #7

When added to an initial rack order, this indicator is used to specify the seventh rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #7 of a multi rack order.

Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 8335-GTG: (#4657)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#4658) - Rack Indicator, Rack #8

When added to an initial rack order, this indicator is used to specify the eighth rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #8 of a multi rack order.

Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 8335-GTG: (#4658)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#4659) - Rack Indicator, Rack #9

When added to an initial rack order, this indicator is used to specify the ninth rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #9 of a multi rack order.

Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 8335-GTG: (#4659)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#4660) - Rack Indicator, Rack #10

When added to an initial rack order, this indicator is used to specify the tenth rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #10 of a multi rack order.

Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 8335-GTG: (#4660)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#4661) - Rack Indicator, Rack #11

When added to an initial rack order, this indicator is used to specify the eleventh rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #11 of a multi rack order.

Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 8335-GTG: (#4661)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#4662) - Rack Indicator, Rack #12

When added to an initial rack order, this indicator is used to specify the twelfth rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #12 of a multi rack order.

Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 8335-GTG: (#4662)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#4663) - Rack Indicator, Rack #13

When added to an initial rack order, this indicator is used to specify the thirteenth rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #13 of a multi rack order.

Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 8335-GTG: (#4663)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#4664) - Rack Indicator, Rack #14

When added to an initial rack order, this indicator is used to specify the fourteenth rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #14 of a multi rack order.

Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 8335-GTG: (#4664)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#4665) - Rack Indicator, Rack #15

When added to an initial rack order, this indicator is used to specify the fifteenth rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #15 of a multi rack order.

Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 8335-GTG: (#4665)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#4666) - Rack Indicator, Rack #16

When added to an initial rack order, this indicator is used to specify the sixteenth rack for a multi rack order.

When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #16 of a multi rack order.

Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.

  • Attributes provided: Rack specify
  • Attributes required: Rack
  • For 8335-GTG: (#4666)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#5000) - Software Preload Required

Indicates that preloaded software and/or consolidated I/O is shipped with the initial order. A maximum of one (#5000) is supported. This feature has country-specific usage.

  • Attributes provided: Software Pre-load
  • Attributes required: N/A
  • For 8335-GTG: (#5000)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#6489) - 4.3m (14-Ft) 3PH/24A 380-415V Power Cord

#6489 is a 14-FT/4.3m 3PH/24A power cable with a Type 46 plug which distributes power from a power source to a Power Distribution Unit.

  • Attributes provided: power cord
  • Attributes required: None
  • For 8335-GTG: (#6489)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#6491) - 4.3m (14-Ft) 1PH/63A 200-240V Power Cord

#6491 is a 14-FT/4.3m 200-240V/63A power cord with a Type 46 plug which distributes power from a power source to a Power Distribution Unit.

  • Attributes provided: power cord
  • Attributes required: None
  • For 8335-GTG: (#6491)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#6492) - 4.3m (14-Ft) 1PH/48-60A 200-240V Power Cord

#6492 is a 14-FT/4.3m 200-240V/48-60A power cord with a Type 46 plug which distributes power from a power source to a Power Distribution Unit.

  • Attributes provided: power cord
  • Attributes required: None
  • For 8335-GTG: (#6492)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#6653) - 4.3m (14-Ft) 3PH/16A 380-415V Power Cord

#6653 is a 14-FT/4.3m 3PH/16A power cord with a Type 46 plug which distributes power from a power source to a Power Distribution Unit.

  • Attributes provided: power cord
  • Attributes required: None
  • For 8335-GTG: (#6653)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#6654) - 4.3m (14-Ft) 1PH/24-30A Pwr Cord

#6654 is a 14-FT/4.3m 200-240V/24A locking power cord with a Type 12 plug which distributes power from a power source to a Power Distribution Unit.

  • Attributes provided: power cord
  • Attributes required: None
  • For 8335-GTG: (#6654)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#6655) - 4.3m (14-Ft) 1PH/24-30A WR Pwr Cord

#6655 is a 14-FT/4.3m 200-240V/24A water-resistant power cord with a Type 40 plug which distributes power from a power source to a Power Distribution Unit.

  • Attributes provided: power cord
  • Attributes required: None
  • For 8335-GTG: (#6655)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#6656) - 4.3m (14-Ft) 1PH/24A Power Cord

#6656 is a 14-FT/4.3m 200-240V/24A power cord with a Type 46 plug which distributes power from a power source to a Power Distribution Unit.

  • Attributes provided: PDU power cord
  • Attributes required: None
  • For 8335-GTG: (#6656)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#6657) - 4.3m (14-Ft) 1PH/32A Power Cord

#6657 is a 14-FT/4.3m 1PH/32A power cord with a Type PDL plug which distributes power from a power source to a Power Distribution Unit.

  • Attributes provided: PDU power cable
  • Attributes required: None
  • For 8335-GTG: (#6657)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#6658) - 4.3m (14-Ft) 1PH/24A Pwr Cd-Korea

#6658 is a 14-FT/4.3m 200-240V/24A power cord with a Type KP plug which distributes power from a power source to a Power Distribution Unit.

  • Attributes provided: PDU power cable
  • Attributes required: None
  • For 8335-GTG: (#6658)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#6667) - 4.3m (14-Ft) 3PH/32A 380-415V Power Cord-Australia

#6667 is a 14-FT/4.3m 380-45V/32A power cord with a Type PDL plug which distributes power from a power source to a Power Distribution Unit.

  • Attributes provided: PDU power cable
  • Attributes required: None
  • For 8335-GTG: (#6667)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#8143) - Linux Software Preinstall

This feature indicates that the Linux operating system is to be preinstalled on the system. Requires feature number 5000.

  • Attributes provided: Linux preinstall
  • Attributes required: Feature number 5000.
  • For 8335-GTG: (#8143)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required:
      • Red Hat Enterprise Linux
      • Refer to Software Requirements for specific O/S levels supported
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#8144) - Linux Software Preinstall (Business Partners)

This feature indicates that the Linux operating system is to be preinstalled on the system. Requires feature number 5000 or 7305. This feature is only available to IBM Business Partner - Solution Providers and IBM Business Partner - Systems Integrators.

  • Attributes provided: Linux preinstall
  • Attributes required: Feature number 5000 or 7305.
  • For 8335-GTG: (#8144)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required:
      • Red Hat Enterprise Linux
      • Refer to Software Requirements for specific O/S levels supported
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9300) - Language Group Specify - US English

English language group for nomenclature and standard publications.

  • Attributes provided: None
  • Attributes required: None
  • For 8335-GTG: (#9300)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9442) - New Red Hat License Core Counter

This feature is used to count the number of cores licensed to run Red Hat Linux.

  • Attributes provided: None
  • Attributes required: None
  • For 8335-GTG: (#9442)
    • Minimum required: 0
    • Maximum allowed: 40 (Initial order maximum: 40)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9445) - Other Linux License Core Counter

This feature is used to count the number of existing Linux licenses transferred from another server.

  • Attributes provided: None
  • Attributes required: None
  • For 8335-GTG: (#9445)
    • Minimum required: 0
    • Maximum allowed: 40 (Initial order maximum: 40)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9446) - 3rd Party Linux License Core Counter

This feature is used to count the number of cores licensed to run 3rd party Linux.

  • Attributes provided: None
  • Attributes required: None
  • For 8335-GTG: (#9446)
    • Minimum required: 0
    • Maximum allowed: 40 (Initial order maximum: 40)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9449) - Other License Core Counter

This feature is used to count the number of other cores licensed.

  • Attributes provided: None
  • Attributes required: None
  • For 8335-GTG: (#9449)
    • Minimum required: 0
    • Maximum allowed: 40 (Initial order maximum: 40)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9461) - Month Indicator

This month indicator is used to create a date stamp to enable CFR splitting and rejoining in order to circumvent the AAS maximum limitation of 30 systems entered on any one order. The quantity ordered for this feature is generated by eConfig.

  • Attributes provided: None
  • Attributes required: None
  • For 8335-GTG: (#9461)
    • Minimum required: 0
    • Maximum allowed: 12 (Initial order maximum: 1)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9462) - Day Indicator

This day indicator is used to create a date stamp to enable CFR splitting and rejoining in order to circumvent the AAS maximum limitation of 30 systems entered on any one order. The quantity ordered for this feature is generated by eConfig.

  • Attributes provided: None
  • Attributes required: None
  • For 8335-GTG: (#9462)
    • Minimum required: 0
    • Maximum allowed: 31 (Initial order maximum: 1)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9463) - Hour Indicator

This hour indicator is used to create a time stamp to enable CFR splitting and rejoining in order to circumvent the AAS maximum limitation of 30 systems entered on any one order. The quantity ordered for this feature is generated by eConfig.

  • Attributes provided: None
  • Attributes required: None
  • For 8335-GTG: (#9463)
    • Minimum required: 0
    • Maximum allowed: 24 (Initial order maximum: 1)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9464) - Minute Indicator

This hour indicator is used to create a time stamp to enable CFR splitting and rejoining in order to circumvent the AAS maximum limitation of 30 systems entered on any one order. The quantity ordered for this feature is generated by eConfig.

  • Attributes provided: None
  • Attributes required: None
  • For 8335-GTG: (#9464)
    • Minimum required: 0
    • Maximum allowed: 60 (Initial order maximum: 1)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9465) - Qty Indicator

This quantity indicator is used to specify the remaining, or N-1 quantity of CFR entities that need to be accumulated for rejoining. The quantity ordered for this feature is generated by eConfig.and is equal to N-1, where 'N' equals the total quantity of CFRs being rejoined.

  • Attributes provided: None
  • Attributes required: None
  • For 8335-GTG: (#9465)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9466) - Countable Member Indicator

This administrative indicator used to identify each CFR associated with a date/time stamp that is eligible for splitting and rejoining. The quantity ordered for this feature is generated by eConfig.

  • Attributes provided: None
  • Attributes required: None
  • For 8335-GTG: (#9466)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9700) - Language Group Specify - Dutch

Dutch language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 8335-GTG: (#9700)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9703) - Language Group Specify - French

French language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 8335-GTG: (#9703)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9704) - Language Group Specify - German

German language group for Nomenclature and Standard Publications.

  • Attributes provided: Language specify
  • Attributes required: None
  • For 8335-GTG: (#9704)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9705) - Language Group Specify - Polish

Polish language group for Nomenclature and Standard Publications.

  • Attributes provided: Language specify
  • Attributes required: None
  • For 8335-GTG: (#9705)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9706) - Language Group Specify - Norwegian

Norwegian language group for Nomenclature and Standard Publications.

  • Attributes provided: Language specify
  • Attributes required: None
  • For 8335-GTG: (#9706)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9707) - Language Group Specify - Portuguese

Portuguese language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 8335-GTG: (#9707)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9708) - Language Group Specify - Spanish

Spanish language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 8335-GTG: (#9708)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9711) - Language Group Specify - Italian

Italian language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 8335-GTG: (#9711)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9712) - Language Group Specify - Canadian French

Canadian French language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 8335-GTG: (#9712)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9714) - Language Group Specify - Japanese

Japanese language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 8335-GTG: (#9714)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9715) - Language Group Specify - Traditional Chinese (Taiwan)

Traditional Chinese language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 8335-GTG: (#9715)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9716) - Language Group Specify - Korean

Korean language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 8335-GTG: (#9716)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9718) - Language Group Specify - Turkish

Turkish language group for nomenclature and publications.

  • Attributes provided: None
  • Attributes required: None
  • For 8335-GTG: (#9718)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9719) - Language Group Specify - Hungarian

Hungarian language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 8335-GTG: (#9719)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9720) - Language Group Specify - Slovakian

Slovakian language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 8335-GTG: (#9720)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9721) - Language Group Specify - Russian

Russian language group for nomenclature and standard publications.

  • Attributes provided: None
  • Attributes required: None
  • For 8335-GTG: (#9721)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9722) - Language Group Specify - Simplified Chinese (PRC)

Simplified Chinese language group for nomenclature and standard publications.

  • Attributes provided: None
  • Attributes required: None
  • For 8335-GTG: (#9722)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9724) - Language Group Specify - Czech

Czech language group for nomenclature and standard publications.

  • Attributes provided: None
  • Attributes required: None
  • For 8335-GTG: (#9724)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9725) - Language Group Specify -- Romanian

Romanian language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 8335-GTG: (#9725)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9726) - Language Group Specify - Croatian

Croatian language group for Nomenclature and Standard Publications.

  • Attributes provided: Language specify
  • Attributes required: None
  • For 8335-GTG: (#9726)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9727) - Language Group Specify -- Slovenian

Slovenian language group for Nomenclature and Standard Publications.

  • Attributes provided: None
  • Attributes required: None
  • For 8335-GTG: (#9727)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9728) - Language Group Specify - Brazilian Portuguese

Brazilian Portuguese language group for Nomenclature and Standard Publications.

  • Attributes provided: Language specify
  • Attributes required: None
  • For 8335-GTG: (#9728)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#9729) - Language Group Specify - Thai

Thai language group for Nomenclature and Standard Publications.

  • Attributes provided: Language specify
  • Attributes required: None
  • For 8335-GTG: (#9729)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#EB27) - QSFP+ 40GBase-SR Transceiver

IBM QSFP+ optical transceiver required for 40 Gbs ports which are not using copper QSFP+ transceiver.

  • Attributes provided: QSFP+ transceiver for 40 Gbs ports.
  • Attributes required: None
  • For 8335-GTG: (#EB27)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EB2B) - 1m (3.3-ft), IBM Passive QSFP+ to QSFP+ Cable (DAC)

QSFP+ cable is used for 40Gb-to-40Gb Ethernet connectivity. Clients can use this QSFP+ Direct Attach Cable for Ethernet connectivity. This copper cable has QSFP+ transceivers already attached to each end.

  • Attributes provided: 1m QSFP+ to QSFP+ Cable
  • Attributes required: QSFP/QSFP+ ports
  • For 8335-GTG: (#EB2B)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EB2H) - 3m (9.8-ft), IBM Passive QSFP+ to QSFP+ Cable (DAC)

QSFP+ cable is used for 40Gb-to-40Gb Ethernet connectivity. Clients can use this QSFP+ Direct Attach Cable for Ethernet connectivity. This copper cable has QSFP+ transceivers already attached to each end.

  • Attributes provided: 3m QSFP+ to QSFP+ Cable
  • Attributes required: QSFP/QSFP+ ports
  • For 8335-GTG: (#EB2H)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EB2J) - 10m (30.3-ft), IBM Passive QSFP+ MTP Optical Cable

QSFP+ cable is used for 40Gb-to-40Gb Ethernet connectivity. Clients can use this QSFP+ Direct Attach Cable for Ethernet connectivity.

  • Attributes provided: 10m QSFP+ to QSFP+ Cable
  • Attributes required: QSFP/QSFP+ ports with optical transceivers
  • For 8335-GTG: (#EB2J)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EB2K) - 30m (90.3-ft), IBM Passive QSFP+ MTP Optical Cable

QSFP+ cable is used for 40Gb-to-40Gb Ethernet connectivity. Clients can use this QSFP+ Direct Attach Cable for Ethernet connectivity.

  • Attributes provided: 30m QSFP+ to QSFP+ Cable
  • Attributes required: QSFP/QSFP+ ports with optical transceivers
  • For 8335-GTG: (#EB2K)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EB2X) - AC Power Supply - 2200 WATT (200-240V/277V)

One 200-240V/277V, 2200 watt AC power supply.

  • Attributes provided:

    AC Power Supply

  • Attributes required: None
  • For 8335-GTG: (#EB2X)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: No
(#EB4J) - 0.5m SFP28/25GbE copper Cable

Feature EB4J is a passive 0,5 meter copper cable that contains a single high-speed copper pair, operating at data rates of up to 25 Gb/s. This cable can be used for either 25Gb Ethernet adapters or switches. Built onto each end of the cable is a passive SFP28 copper cable transceiver. Cables are available in various lengths: 0.5M - #EB4J, 1.0M=#EB4K, 1.5M=#EB4L, 2.0M=#EB4M

  • Attributes provided: Copper cable with SFP28 transceivers
  • Attributes required: None
  • For 8335-GTG: (#EB4J)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EB4K) - 1.0m SFP28/25GbE copper Cable

Feature EB4K is a passive 1.0 meter copper cable that contains a single high-speed copper pair, operating at data rates of up to 25 Gb/s. This cable can be used for either 25Gb Ethernet adapters or switches. Built onto each end of the cable is a passive SFP28 copper cable transceiver. Cables are available in various lengths: 0.5M - #EB4J, 1.0M=#EB4K, 1.5M=#EB4L, 2.0M=#EB4M

  • Attributes provided: Copper cable with SFP28 transceivers
  • Attributes required: None
  • For 8335-GTG: (#EB4K)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EB4L) - 1.5m SFP28/25GbE copper Cable

Feature EB4L is a passive 1.5 meter copper cable that contains a single high-speed copper pair, operating at data rates of up to 25 Gb/s. This cable can be used for either 25Gb Ethernet adapters or switches. Built onto each end of the cable is a passive SFP28 copper cable transceiver. Cables are available in various lengths: 0.5M - #EB4J, 1.0M=#EB4K, 1.5M=#EB4L, 2.0M=#EB4M

  • Attributes provided: Copper cable with SFP28 transceivers
  • Attributes required: None
  • For 8335-GTG: (#EB4L)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EB4M) - 2.0m SFP28/25GbE copper Cable

Feature EB4M is a passive 2.0 meter copper cable that contains a single high-speed copper pair, operating at data rates of up to 25 Gb/s. This cable can be used for either 25Gb Ethernet adapters or switches. Built onto each end of the cable is a passive SFP28 copper cable transceiver. Cables are available in various lengths: 0.5M - #EB4J, 1.0M=#EB4K, 1.5M=#EB4L, 2.0M=#EB4M

  • Attributes provided: Copper cable with SFP28 transceivers
  • Attributes required: None
  • For 8335-GTG: (#EB4M)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EB4P) - 2.0m QSFP28/100GbE copper split Cable to SFP28 4x25GbE

Feature EB4P is a 2.0 meter, active optical 100Gb E to 4x25Gb E splitter cable. It provides connectivity between system units with a QSFP28 port on one side and up to four different SFP28 ports on the other side, such as a switch and four servers.

  • Attributes provided: Copper splitter cable with QSFP28 and 4x SFP28 transceivers
  • Attributes required: None
  • For 8335-GTG: (#EB4P)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EB50) - 0.5m EDR IB Copper Cable QSFP28

0.5 meter length copper twinax cable, also called a DAC (Direct Attached Copper) cable. The cable can be used for either 100Gb EDR InfiniBand (IB) adapters or IB switches. Built onto each end of the cable is a passive Quad (4-channel) Small Form-Factor Pluggable (QSFP28) copper cable transceiver. Cable can also be used for FDR IB (56Gb). Cables are available in various lengths: 0.5m = #EB50, 1m = #EB51, 2m = #EB52, 1.5m = #EB54 See also optical fiber cables for longer lengths such as #EB5A through #EB5H.

  • Attributes provided: Copper twinax cable with QSFP28 transceivers
  • Attributes required: None
  • For 8335-GTG: (#EB50)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EB51) - 1.0m EDR IB Copper Cable QSFP28

1.0 meter length copper twinax cable, also called a DAC (Direct Attached Copper) cable. The cable can be used for either 100Gb EDR InfiniBand (IB) adapters or IB switches. Built onto each end of the cable is a passive Quad (4-channel) Small Form-Factor Pluggable (QSFP28) copper cable transceiver. Cable can also be used for FDR IB (56Gb). Cables are available in various lengths: 0.5m = #EB50, 1m = #EB51, 2m = #EB52, 1.5m = #EB54 See also optical fiber cables for longer lengths such as #EB5A through #EB5H.

  • Attributes provided: Copper twinax cable with QSFP28 transceivers
  • Attributes required: None
  • For 8335-GTG: (#EB51)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EB52) - 2.0m EDR IB Copper Cable QSFP28

2.0 meter length copper twinax cable, also called a DAC (Direct Attached Copper) cable. The cable can be used for either 100Gb EDR InfiniBand (IB) adapters or IB switches. Built onto each end of the cable is a passive Quad (4-channel) Small Form-Factor Pluggable (QSFP28) copper cable transceiver. Cable can also be used for FDR IB (56Gb). Cables are available in various lengths: 0.5m = #EB50, 1m = #EB51, 2m = #EB52, 1.5m = #EB54 See also optical fiber cables for longer lengths such as #EB5A through #EB5H.

  • Attributes provided: Copper twinax cable with QSFP28 transceivers
  • Attributes required: None
  • For 8335-GTG: (#EB52)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EB54) - 1.5m EDR IB Copper Cable QSFP28

1.5 meter length copper twinax cable, also called a DAC (Direct Attached Copper) cable. The cable can be used for either 100Gb EDR InfiniBand (IB) adapters or IB switches. Built onto each end of the cable is a passive Quad (4-channel) Small Form-Factor Pluggable (QSFP28) copper cable transceiver. Cable can also be used for FDR IB (56Gb). Cables are available in various lengths: 0.5m = #EB50, 1m = #EB51, 2m = #EB52, 1.5m = #EB54 See also optical fiber cables for longer lengths such as #EB5A through #EB5H.

  • Attributes provided: Copper twinax cable with QSFP28 transceivers
  • Attributes required: None
  • For 8335-GTG: (#EB54)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EB59) - 100Gb Optical Transceiver QSFP28

One optical transceiver for 100Gb Ethernet adapter such as #EC3L or #EC3M using QSFP28. Does not include cable.

See also AOC fiber cables which include QSFP28 transceivers EB5R - EB5Y.

  • Attributes provided: Optical Transceiver QSFP28 100Gb.
  • Attributes required: Port on adapter with QSFP28 socket.
  • For 8335-GTG: (#EB59)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EB5A) - 3m EDR IB Optical Cable QSFP28

3 meter length optical fiber cable, also called an AOC (Active Optical Cable). The cable can be used for either 100Gb EDR InfiniBand (IB) adapters or IB switches. Built onto each end of the cable is a active Quad (4-channel) Small Form-Factor Pluggable (QSFP28) optical cable transceiver. Cables are available in various lengths: 3m = #EB5A, 5m = #EB5B, 10m = #EB5C, 15m = #EB5D, 20m = #EB5E, 30m = #EB5F, and 50m = #EB5G, 100m = #EB5H. See also copper twinax cables for shorter lengths such as #EB50 through #EB54. Limitation: Adapter and switch must have been manufactured by Mellanox to use this cable. Cable is not supported for FDR IB (56Gb).

  • Attributes provided: Optical fiber cable with QSFP28 transceivers
  • Attributes required: None
  • For 8335-GTG: (#EB5A)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EB5B) - 5m EDR IB Optical Cable QSFP28

5 meter length optical fiber cable, also called an AOC (Active Optical Cable). The cable can be used for either 100Gb EDR InfiniBand (IB) adapters or IB switches. Built onto each end of the cable is a active Quad (4-channel) Small Form-Factor Pluggable (QSFP28) optical cable transceiver. Cables are available in various lengths: 3m = #EB5A, 5m = #EB5B, 10m = #EB5C, 15m = #EB5D, 20m = #EB5E, 30m = #EB5F, and 50m = #EB5G, 100m = #EB5H. See also copper twinax cables for shorter lengths such as #EB50 through #EB54. Limitation: Adapter and switch must have been manufactured by Mellanox to use this cable. Cable is not supported for FDR IB (56Gb).

  • Attributes provided: Optical fiber cable with QSFP28 transceivers
  • Attributes required: None
  • For 8335-GTG: (#EB5B)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EB5C) - 10m EDR IB Optical Cable QSFP28

10 meter length optical fiber cable, also called an AOC (Active Optical Cable). The cable can be used for either 100Gb EDR InfiniBand (IB) adapters or IB switches. Built onto each end of the cable is a active Quad (4-channel) Small Form-Factor Pluggable (QSFP28) optical cable transceiver. Cables are available in various lengths: 3m = #EB5A, 5m = #EB5B, 10m = #EB5C, 15m = #EB5D, 20m = #EB5E, 30m = #EB5F, and 50m = #EB5G, 100m = #EB5H. See also copper twinax cables for shorter lengths such as #EB50 through #EB54. Limitation: Adapter and switch must have been manufactured by Mellanox to use this cable. Cable is not supported for FDR IB (56Gb).

  • Attributes provided: Optical fiber cable with QSFP28 transceivers
  • Attributes required: None
  • For 8335-GTG: (#EB5C)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EB5D) - 15m EDR IB Optical Cable QSFP28

15 meter length optical fiber cable, also called an AOC (Active Optical Cable). The cable can be used for either 100Gb EDR InfiniBand (IB) adapters or IB switches. Built onto each end of the cable is a active Quad (4-channel) Small Form-Factor Pluggable (QSFP28) optical cable transceiver. Cables are available in various lengths: 3m = #EB5A, 5m = #EB5B, 10m = #EB5C, 15m = #EB5D, 20m = #EB5E, 30m = #EB5F, and 50m = #EB5G, 100m = #EB5H. See also copper twinax cables for shorter lengths such as #EB50 through #EB54. Limitation: Adapter and switch must have been manufactured by Mellanox to use this cable. Cable is not supported for FDR IB (56Gb).

  • Attributes provided: Optical fiber cable with QSFP28 transceivers
  • Attributes required: None
  • For 8335-GTG: (#EB5D)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EB5E) - 20m EDR IB Optical Cable QSFP28

20 meter length optical fiber cable, also called an AOC (Active Optical Cable). The cable can be used for either 100Gb EDR InfiniBand (IB) adapters or IB switches. Built onto each end of the cable is a active Quad (4-channel) Small Form-Factor Pluggable (QSFP28) optical cable transceiver. Cables are available in various lengths: 3m = #EB5A, 5m = #EB5B, 10m = #EB5C, 15m = #EB5D, 20m = #EB5E, 30m = #EB5F, and 50m = #EB5G, 100m = #EB5H. See also copper twinax cables for shorter lengths such as #EB50 through #EB54. Limitation: Adapter and switch must have been manufactured by Mellanox to use this cable. Cable is not supported for FDR IB (56Gb).

  • Attributes provided: Optical fiber cable with QSFP28 transceivers
  • Attributes required: None
  • For 8335-GTG: (#EB5E)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EB5F) - 30m EDR IB Optical Cable QSFP28

30 meter length optical fiber cable, also called an AOC (Active Optical Cable). The cable can be used for either 100Gb EDR InfiniBand (IB) adapters or IB switches. Built onto each end of the cable is a active Quad (4-channel) Small Form-Factor Pluggable (QSFP28) optical cable transceiver. Cables are available in various lengths: 3m = #EB5A, 5m = #EB5B, 10m = #EB5C, 15m = #EB5D, 20m = #EB5E, 30m = #EB5F, and 50m = #EB5G, 100m = #EB5H. See also copper twinax cables for shorter lengths such as #EB50 through #EB54. Limitation: Adapter and switch must have been manufactured by Mellanox to use this cable. Cable is not supported for FDR IB (56Gb).

  • Attributes provided: Optical fiber cable with QSFP28 transceivers
  • Attributes required: None
  • For 8335-GTG: (#EB5F)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EB5G) - 50m EDR IB Optical Cable QSFP28

50 meter length optical fiber cable, also called an AOC (Active Optical Cable). The cable can be used for either 100Gb EDR InfiniBand (IB) adapters or IB switches. Built onto each end of the cable is a active Quad (4-channel) Small Form-Factor Pluggable (QSFP28) optical cable transceiver. Cables are available in various lengths: 3m = #EB5A, 5m = #EB5B, 10m = #EB5C, 15m = #EB5D, 20m = #EB5E, 30m = #EB5F, and 50m = #EB5G, 100m = #EB5H. See also copper twinax cables for shorter lengths such as #EB50 through #EB54. Limitation: Adapter and switch must have been manufactured by Mellanox to use this cable. Cable is not supported for FDR IB (56Gb).

  • Attributes provided: Optical fiber cable with QSFP28 transceivers
  • Attributes required: None
  • For 8335-GTG: (#EB5G)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EB5H) - 100m EDR IB Optical Cable QSFP28

100 meter length optical fiber cable, also called an AOC (Active Optical Cable). The cable can be used for either 100Gb EDR InfiniBand (IB) adapters or IB switches. Built onto each end of the cable is a active Quad (4-channel) Small Form-Factor Pluggable (QSFP28) optical cable transceiver. Cables are available in various lengths: 3m = #EB5A, 5m = #EB5B, 10m = #EB5C, 15m = #EB5D, 20m = #EB5E, 30m = #EB5F, and 50m = #EB5G, 100m = #EB5H. See also copper twinax cables for shorter lengths such as #EB50 through #EB54. Limitation: Adapter and switch must have been manufactured by Mellanox to use this cable. Cable is not supported for FDR IB (56Gb).

  • Attributes provided: Optical fiber cable with QSFP28 transceivers
  • Attributes required: None
  • For 8335-GTG: (#EB5H)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EB5J) - 0.5m 100GbE Copper Cable QSFP28

0.5 meter length passive copper cable with QSFP28 tranceivers on each end. The cable used for 100Gb Ethernet adapters or switches. Copper cable is also called "copper twinax" or "DAC" (Direct Attach Copper).

Cables are available in various lengths. See shorter passive copper cables #EB5J - #EB5M (0.5M - 2.0M) or see active optical fiber cables #EJ5R - #EJ5Y (3M - 100M).

  • Attributes provided: Copper cable with QSFP28 transceivers
  • Attributes required: None
  • For 8335-GTG: (#EB5J)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EB5K) - 1.0m 100GbE Copper Cable QSFP28

1.0 meter length passive copper cable with QSFP28 tranceivers on each end. The cable used for 100Gb Ethernet adapters or switches. Copper cable is also called "copper twinax" or "DAC" (Direct Attach Copper).

Cables are available in various lengths. See shorter passive copper cables #EB5J - #EB5M (0.5M - 2.0M) or see active optical fiber cables #EJ5R - #EJ5Y (3M - 100M).

  • Attributes provided: Copper cable with QSFP28 transceivers
  • Attributes required: None
  • For 8335-GTG: (#EB5K)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EB5L) - 1.5m 100GbE Copper Cable QSFP28

1.5 meter length passive copper cable with QSFP28 tranceivers on each end. The cable used for 100Gb Ethernet adapters or switches. Copper cable is also called "copper twinax" or "DAC" (Direct Attach Copper).

Cables are available in various lengths. See shorter passive copper cables #EB5J - #EB5M (0.5M - 2.0M) or see active optical fiber cables #EJ5R - #EJ5Y (3M - 100M).

  • Attributes provided: Copper cable with QSFP28 transceivers
  • Attributes required: None
  • For 8335-GTG: (#EB5L)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EB5M) - 2.0m 100GbE Copper Cable QSFP28

2.0 meter length passive copper cable with QSFP28 tranceivers on each end. The cable used for 100Gb Ethernet adapters or switches. Copper cable is also called "copper twinax" or "DAC" (Direct Attach Copper).

Cables are available in various lengths. See shorter passive copper cables #EB5J - #EB5M (0.5M - 2.0M) or see active optical fiber cables #EJ5R - #EJ5Y (3M - 100M).

  • Attributes provided: Copper cable with QSFP28 transceivers
  • Attributes required: None
  • For 8335-GTG: (#EB5M)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EB5N) - 25m EDR IB Optical Cable QSFP28

25 meter length optical fiber cable, also called an AOC (Active Optical Cable). The cable can be used for either 100Gb EDR InfiniBand (IB) adapters or IB switches. Built onto each end of the cable is a active Quad (4-channel) Small Form-Factor Pluggable (QSFP28) optical cable transceiver.

Cables are available in various lengths: 3m = #EB5A, 5m = #EB5B, 10m = #EB5C, 15m = #EB5D, 20m = #EB5E, 25m = #EB5N, 30m = #EB5F, and 50m = #EB5G, 100m = #EB5H. See also copper twinax cables for shorter lengths such as #EB50 through #EB54.

Limitation: Adapter and switch must have been manufactured by Mellanox to use this cable. Cable is not supported for FDR IB (56Gb).

  • Attributes provided: Optical fiber cable with QSFP28 transceivers
  • Attributes required: None
  • For 8335-GTG: (#EB5N)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EB5R) - 3m 100GbE Optical Cable QSFP28 (AOC)

3 meter length Active Optical fiber Cable (AOC) with QSFP28 tranceivers on each end. The cable used for 100Gb Ethernet adapters or switches.

Cables are available in various lengths. See shorter passive copper cables #EB5J - #EJM (0.5m - 2.0m) or see active optical fiber cables #EJ5R - #EJ5Y (3m - 100m).

  • Attributes provided: Optical fiber cable with QSFP28 transceivers
  • Attributes required: None
  • For 8335-GTG: (#EB5R)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EB5S) - 5m 100GbE Optical Cable QSFP28 (AOC)

5 meter length Active Optical fiber Cable (AOC) with QSFP28 tranceivers on each end. The cable used for 100Gb Ethernet adapters or switches.

Cables are available in various lengths. See shorter passive copper cables #EB5J - #EJM (0.5m - 2.0m) or see active optical fiber cables #EJ5R - #EJ5Y (3m - 100m).

  • Attributes provided: Optical fiber cable with QSFP28 transceivers
  • Attributes required: None
  • For 8335-GTG: (#EB5S)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EB5T) - 10m 100GbE Optical Cable QSFP28 (AOC)

10 meter length Active Optical fiber Cable (AOC) with QSFP28 tranceivers on each end. The cable used for 100Gb Ethernet adapters or switches.

Cables are available in various lengths. See shorter passive copper cables #EB5J - #EJM (0.5m - 2.0m) or see active optical fiber cables #EJ5R - #EJ5Y (3m - 100m).

  • Attributes provided: Optical fiber cable with QSFP28 transceivers
  • Attributes required: None
  • For 8335-GTG: (#EB5T)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EB5U) - 15m 100GbE Optical Cable QSFP28 (AOC)

15 meter length Active Optical fiber Cable (AOC) with QSFP28 tranceivers on each end. The cable used for 100Gb Ethernet adapters or switches.

Cables are available in various lengths. See shorter passive copper cables #EB5J - #EJM (0.5m - 2.0m) or see active optical fiber cables #EJ5R - #EJ5Y (3m - 100m).

  • Attributes provided: Optical fiber cable with QSFP28 transceivers
  • Attributes required: None
  • For 8335-GTG: (#EB5U)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EB5V) - 20m 100GbE Optical Cable QSFP28 (AOC)

20 meter length Active Optical fiber Cable (AOC) with QSFP28 tranceivers on each end. The cable used for 100Gb Ethernet adapters or switches.

Cables are available in various lengths. See shorter passive copper cables #EB5J - #EJM (0.5m - 2.0m) or see active optical fiber cables #EJ5R - #EJ5Y (3m - 100m).

  • Attributes provided: Optical fiber cable with QSFP28 transceivers
  • Attributes required: None
  • For 8335-GTG: (#EB5V)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EB5W) - 30m 100GbE Optical Cable QSFP28 (AOC)

30 meter length Active Optical fiber Cable (AOC) with QSFP28 tranceivers on each end. The cable used for 100Gb Ethernet adapters or switches.

Cables are available in various lengths. See shorter passive copper cables #EB5J - #EJM (0.5m - 2.0m) or see active optical fiber cables #EJ5R - #EJ5Y (3m - 100m).

  • Attributes provided: Optical fiber cable with QSFP28 transceivers
  • Attributes required: None
  • For 8335-GTG: (#EB5W)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EB5X) - 50m 100GbE Optical Cable QSFP28 (AOC)

50 meter length Active Optical fiber Cable (AOC) with QSFP28 tranceivers on each end. The cable used for 100Gb Ethernet adapters or switches.

Cables are available in various lengths. See shorter passive copper cables #EB5J - #EJM (0.5m - 2.0m) or see active optical fiber cables #EJ5R - #EJ5Y (3m - 100m).

  • Attributes provided: Optical fiber cable with QSFP28 transceivers
  • Attributes required: None
  • For 8335-GTG: (#EB5X)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EB5Y) - 100m 100GbE Optical Cable QSFP28 (AOC)

100 meter length Active Optical fiber Cable (AOC) with QSFP28 tranceivers on each end. The cable used for 100Gb Ethernet adapters or switches.

Cables are available in various lengths. See shorter passive copper cables #EB5J - #EJM (0.5m - 2.0m) or see active optical fiber cables #EJ5R - #EJ5Y (3m - 100m).

  • Attributes provided: Optical fiber cable with QSFP28 transceivers
  • Attributes required: None
  • For 8335-GTG: (#EB5Y)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EC16) - Open Power non-virtualized configuration

Open Power firmware for Power non-virtualized configuration.

  • Attributes provided: Allows Linux to be used on bare metal without any virtualization
  • Attributes required: None
  • For 8335-GTG: (#EC16)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#EC3L) - PCIe3 LP 2-port 100GbE (NIC& RoCE) QSFP28 Adapter x16

This PCIe Gen3 Ethernet x16 adapter provides two 100 Gb QSFP28 ports. The adapter supports both NIC and IBTA RoCE standards. RoCE is Remote Direct Memory Access (RDMA) over Converged Ethernet. Using RoCE, the adapter can support significantly greater bandwidth with low latency and minimize CPU overhead by more efficiently using memory access. This offloads the CPU from I/O networking tasks, improving performance and scalability.

IBM offers either passive copper twinax cables up to 2 meter in length or active optical cables up to 100 meters in length. See features #EB5J - #EB5M for a 0.5m, 1.0m, 1.5m and 2.0m copper cable. See features #EB5R - #EB5Y for a 3m, 5m, 10m, 15m, 20m, 30m, 50m or 100m active optical cable. Transceivers are included on each end of these QSFP28 cables. Alternatively to the above supported cables, you may chose to order an IBM qualified and supported QSFP28 optical transceiver (feature #EB59) to put into the adapter and provide your own 100GE optical cabling with your own QSP28 optical transceiver for the other end.

Either one or both of the adapter's two QSP28 ports can be populated. When two ports are filled, both can have copper cables, both can have optical cables, or one can be copper and one can be optical.

Feature code #EC3L and #EC3M have identical electronics and function and CCIN (2CEC), but have different tail stock brackets. #EC3L is low profile and #EC3M is full high. The adapter is based on a Mellanox ConnectX-4 adapter which uses a ConnectX-4 EN Network Controller.

Attributes:

  • PCI Express 3.0 (up to 8GT/s) x16
  • PCIe Gen 3.0 compliant, 1.1 and 2.0 compatible
  • RDMA over Converged Ethernet (RoCE)
  • NIC and RoCE are concurrently supported
  • RoCE supported on Linux and AIX (7.2 and later)
  • NIC supported on all OSes
  • TCP/UDP/IP stateless offload
  • LSO, LRO, checksum offload
  • NIM boot support
  • Backward compatible with 40Gb Ethernet when using compatible cables/transceivers.
  • Attributes provided: 2-port 100Gb Ethernet
  • Attributes required: x16 PCIe Gen3 slot
  • For 8335-GTG: (#EC3L)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EC4J) - NVIDIA Tesla V100 GPU with NVLINK Air-Cooled (16 GB)
  • For 8335-GTG: (#EC4J)
    • Minimum required: 2
    • Maximum allowed: 4 (Initial order maximum: 4)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EC5A) - PCIe3 LP 1.6 TB SSD NVMe adapter

The PCIe3 x8 NVMe 1.6 TB SSD NVMe Adapter is a Peripheral Component Interconnect Express (PCIe) generation 3 (Gen3) x8 adapter. The adapter can be used in either a x8 or x16 PCIe (Gen3) slot in the system and uses Non-Volatile Memory Express (NVMe).

NVMe is a high performance software interface that can read/write flash memory. Compared to a SAS or SATA SSD, the NVMe Flash adapter provides more read/write input/output operations per second (IOPS) and larger throughput (GB/sec). The NVMe Flash Adapter is read intensive and is not designed for high write intensive workloads. At about 8,760 to 17,000 TB of writes to the adapter, it will be at its maximum projected write capability. The nature of the workload has a great impact on the maximum write capacity. If a high percentage of more sequentially oriented writes is used instead of random writes, the maximum write capacity will be closer to the larger value in the range.

In the case of a high percentage of random writes, the maximum will be closer to the smaller value in the range. Writes past the adapter's maximum write capacity will continue to work for some period of time, but much more slowly. A Predictive Failure Analysis message will indicate that it is time to replace the adapter if enabled by the system administrator. After the warranty period, if the maximum write capability is achieved, the adapter's replacement is not covered under IBM maintenance.

This adapter has protection against single Flash channel failures. To prevent the entire adapter from failing, software RAID should be used. For high value applications where the content in the adapter must be protected, additional NVMe Flash adapters with OS mirroring or software Redundant Array of Independent Disks (RAID) are recommended. This adapter is not supported in the PCIe Gen3 I/O drawer.

  • For 8335-GTG: (#EC5A)
    • Minimum required: 0
    • Maximum allowed: 3 (Initial order maximum: 3)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EC62) - PCIe4 LP 1-port 100Gb EDR IB CAPI adapter

The PCIe Gen4 x16 1-port InfiniBand EDR adapter provides high speed connectivity with other servers or IB switches. The port's maximum of 100Gb assumes no other system and/or switch bottlenecks are present. A PCIe Gen4 x16 PCIe slot is required. This adapter is sourced from Mellanox Corporation. based on ConnectX-5 technology. The adapter supports the InfiniBand Trade Association (IBTA) specification version 2.

The 100Gb port has a QSFP+ connection which supports EDR cables, either EDR DAC or EDR optical. Transceivers are included in the cables. IBM cable features EB50-EB54 (copper shorter distance) and #EB5A-EB5H (optical longer distance) are supported or their copper or optical Mellanox equivalents are supported. Other cables are not supported.

#EC62 and #EC63 adapters are electronically and functionally identical with the same CCIN of 2CF1. #EC62 is low profile and #EC63 is full high.

Limitation: Adapter does not fit in x8 PCIe slot. Adapter is not supported in a PCIe Gen3 I/O drawer.

  • For 8335-GTG: (#EC62)
    • Minimum required: 0
    • Maximum allowed: 3 (Initial order maximum: 3)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EC64) - PCIe4 LP 2-port 100Gb EDR IB CAPI adapter

The PCIe Gen4 x16 2-port InfiniBand EDR adapter provides high speed connectivity with other servers or IB switches. Each port maximum of 100Gb assumes no other system and/or switch bottlenecks are present. A PCIe Gen4 x16 PCIe slot is required. This adapter is sourced from Mellanox Corporation. based on ConnectX-5 technology. The adapter supports the InfiniBand Trade Association (IBTA) specification version 2.

The two 100Gb ports have QSFP+ connections which support EDR cables, either EDR DAC or EDR optical. One adapter can support either or both types of cable. The user can choose to cable up just one port if they desire. Transceivers are included in the cables. IBM cable features EB50-EB54 (copper shorter distance) and #EB5A-EB5H (optical longer distance) are supported or their copper or optical Mellanox equivalents are supported. Other cables are not supported.

#EC64 and #EC65 adapters are electronically and functionally identical with the same CCIN of 2CF2. #EC64 is low profile and #EC65 is full high.

Limitation: Adapter does not fit in x8 PCIe slot. Adapter is not supported in a PCIe Gen3 I/O drawer.

  • For 8335-GTG: (#EC64)
    • Minimum required: 0
    • Maximum allowed: 3 (Initial order maximum: 3)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#ECBN) - 5m (16.4-ft), IBM Passive QSFP+ to QSFP+ Cable (DAC)

QSFP+ cable is used for 40Gb-to-40Gb Ethernet connectivity. clients can use this QSFP+ Direct Attach Cable for Ethernet connectivity. This copper cable has QSFP+ transceivers already attached to each end.

  • Attributes provided: 5m QSFP+ to QSFP+ Cable
  • Attributes required: QSFP/QSFP+ ports
  • For 8335-GTG: (#ECBN)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#ECL0) - Power ACP Solution specify

This is an indicator for Power Accelerated Computing Platform.

  • Attributes provided: Solution Indicator
  • Attributes required: None
  • For 8335-GTG: (#ECL0)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: No
(#ECP0) - Cloud Private Solution

This feature indicates that it is a Cloud Private Solution.

  • Attributes provided: None
  • Attributes required: None
  • For 8335-GTG: (#ECP0)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES:
(#ECSF) - Custom Service Specify, Montpellier, France

Having #ECSF on the order, will cause the order to be routed to France and the machine to be internally routed to the CSC build area.

  • Attributes provided: Customization
  • Attributes required: None
  • For 8335-GTG: (#ECSF)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: N/A
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#ECW0) - Optical Wrap Plug

A wrap plug is a small connector designed to perform a diagnostic test called a loopback test. This wrap plug is inserted into a SR optical port on a PCIe Fibre Channel adapter or a SR or LR optical port on a PCIe Ethernet adapter

This is a multi-mode LC fiber optic wrap plug with an inside/ outside optics diameter of 50/125. Its IBM part number as of early 2016 is 12R9314. An earlier equivalent function IBM part number which is no longer shipped is 11P3847.

It is strongly recommended that Fibre Channel adapters (HBAs) fill any empty adapter ports with a wrap plug. There is no technical issue leaving a port empty. However, filling all ports with a cable to a device/switch or with a wrap plug can speed the booting/IPLing of a partition and can avoid error messages uselessly pointing to a planned empty port.

There is no technical issue leaving an Ethernet port empty. Whether an Ethernet port is empty or contains a wrap plug should not impact boot/IPL time or impact empty-port messages.

  • Attributes provided: Wrap plug
  • Attributes required: None
  • For 8335-GTG: (#ECW0)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EHL9) - Marketing Specify - NVIDIA GPU
  • Attributes provided: None
  • Attributes required: None
  • For 8335-GTG: (#EHL9)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EJTX) - Rack-mount Fixed Rail Kit

Feature provides a rack fixed rail kit used to install a rack-mount 2U server such as 8335-CGA or 8335-GTA in an IBM or OEM 19-inch rack. Rails adjust from approximately 585 mm (23 inches) to 755 mm (29.5 inches) in depth. See also feature #EJTY for alternative rails which allow he server to be slid in and out of the rack.

  • Attributes provided: Fixed rails
  • Attributes required: 2U server using these rails
  • For 8335-GTG: (#EJTX)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EJTY) - Rack-mount Slide Rail Kit

Feature provides a rack slide rail kit used to install a rack-mount 2U server such as 8335-CGA or 8335-GTA in an IBM or OEM 19-inch rack. A cable management arm is included in kit to allow the server to be slid out of the rack without unplugging cables/cords. Plan for about 1 meter length of cable/cord to be used with the arm. Rails adjust from approximately 22.5 to 32 inches in depth. See also feature #EJTX for alternative rails which are fixed and do not allow he server to be slid in and out of the rack.

  • Attributes provided: Slide rails
  • Attributes required: 2U server using these rails
  • For 8335-GTG: (#EJTY)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EL3Z) - PCIe2 LP 2-port 10/1GbE BaseT RJ45 Adapter

PCIe Gen2 short x8 adapter which provides two 10G-BaseT ports. The ports are RJ45. The ports default to auto negotiate the highest speed either 10Gb (10GBaseT), 1Gb (1000BaseT) or 100Mb (100BaseT) full duplex. Each RJ45 port's configuration is independent of the other. The adapter supports Ethernet NIC (Network Interface Card) traffic. CCIN is 2CC4.

The RJ45 ports use 4-pair CAT-6A cabling for distances of up to 100 meters or CAT-6 cabling for distances up to 37 meters. CAT5 cabling is not tested and is not supported.

#EN0W and #EN0X are electronically identical with the same CCIN of 2CC4. #EN0W has a full high tail stock and #EN0X has a low profile tail stock.

Details for the ports include:

  • VIOS NIM and LINUX NETWORK INSTALL is supported.
  • IEEE 802.3an (10GBASE-T), IEEE 802.3ab (1000BASE-T GbE), IEEEu (100BASE-T), 802.1p priority, 802.1Q VLAN tagging, 802.3x flow control, 802.3ad load-balancing and failover
  • Link aggregation, IEEE 802.3ad 802.3
  • Multiple MAC addresses / promiscuous mode (for PowerVM/VIOS) per interface
  • Message Signalling Interrupt (MSI-X, MSI) support of legacy pin interrupts
  • Ether II and IEEE 802.3 encapsulated frames
  • Jumbo frames up to 9.6 Kbytes
  • TCP checksum offload for IPv4 and IPv6
  • TCP segmentation Offload (TSO)
  • RSS (Receive Side Scaling) support for IPv4, IPv6 and UDP.
  • UDP checksum offload for IPv4 and IPv6
  • Linux provides software iSCSI support through the adapter.
  • Attributes provided: Two 10G-BaseT ports
  • Attributes required: PCIe Gen2 or Gen3 slot - low profile
  • For 8335-GTG: (#EL3Z)
    • Minimum required: 0
    • Maximum allowed: 3 (Initial order maximum: 3)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EL43) - PCIe3 LP 2-port 16Gb Fibre Channel Adapter

PCIe Gen3 16 Gigabit dual-port Fibre Channel (FC) Adapter is a high-performance 8x short form adapter based on the Emulex LPe16002B PCIe Host Bus Adapter (HBA). The adapter provides two ports of 16Gb Fibre Channel capability using SR optics. Each port can provide up to 16Gb Fibre Channel functions simultaneously.

Each port provides single initiator capability over a fibre link or with NPIV, multiple initiator capability is provided. The ports are SFP+ and include an optical SR transceiver. The ports have LC type connectors and utilize shortwave laser optics. The adapter operates at link speeds of 4, 8 and 16 Gbps and will automatically negotiate to the highest speed possible. LEDs on each port provide information on the status and link speed of the port.

The adapter connects to a Fibre Channel switch at 4Gb, 8Gb or 16Gb. It can directly attach to a device without a switch at 16Gb under VIOS or Linux. Attachment without a switch is not supported at 4Gb or 8Gb

N_Port ID Virtualization (NPIV) capability is supported through VIOS.

Feature #EL43 and #EL5B are electronically identical. They differ physically only that EL5B has a tail stock for full high PCIe slots and #EL43 has a tail stock for low profile PCIe slots. CCIN is 577F for both features.

Cables are the responsibility of the customer. Use multimode fibre optic cables with short-wave lasers that adhere to the following specifications:

  • OM4 - multimode 50/125 micron fibre, 4700 MHz*km bandwidth
  • OM3 - multimode 50/125 micron fibre, 2000 MHz*km bandwidth
  • OM2 - multimode 50/125 micron fibre, 500 MHz*km bandwidth
  • OM1 - multimode 62.5/125 micron fibre, 200 MHz*km bandwidth

The maximum cable lengths at the three different link speeds are:

Cable   4 Gbps   8 Gbps   16 Gbps
---------------------------------
OM4     400m     190m     125m
OM3     380m     150m     100m
OM2     150m     50m      35m
OM1     70m      21m      15m
  • Attributes provided: Two 16Gb FC ports (with LC connectors)
  • Attributes required: PCIe Gen3 or Gen2 slot in supported server
  • For 8335-GTG: (#EL43)
    • Minimum required: 0
    • Maximum allowed: 3 (Initial order maximum: 3)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EL4M) - PCIe2 LP 4-port 1GbE Adapter

This short PCIe Gen2 adapter provides four 1Gb Ethernet ports that can be configured to run at 1000, 100 or 10 Mbps. 4-pair CAT-5 Unshielded Twisted Pair (UTP) cables up to 100 meters in length are attached to the copper RJ45 connectors. Each port is independent of one another and supports full-duplex or half-duplex. 1000 Mbps speed is not supported in Half Duplex (HDX) mode. Feature #EL4M and #EL4L are electronically identical and have the same CCIN of 576F. #EL4M indicates a low profile tail stock while #EL4L indicates a full high tail stock. (See also equivalent features #5260 and #5899).

Details for the ports include:

  • Linux install support
  • IEEE 802.3ab (1 GbE), 802.1p priority, 802.1Q VLAN tagging, 802.3x flow control, 802.3ad load-balancing and failover,
  • Link aggregation, IEEE 802.3ad 802.3
  • Multiple MAC addresses per interface
  • MSI-X, MSI and support of legacy pin interrupts
  • Ether II and IEEE 802.3 encapsulated frames
  • Jumbo frames up to 9.6 Kbytes
  • TCP checksum offload for IPv4 and IPv6
  • TCP segmentation Offload (TSO) for IPv4 and IPv6
  • UDP checksum offload for IPv4 and IPv6
  • Linux provide software iSCSI support through the adapter. Linux can also leverage adapter hardware support including initiator and header & data digest (CRC) generation and checking
  • Attributes provided: Four-port 1 Gb Ethernet
  • Attributes required: 1 Low Profile (LP) PCIe slot
  • For 8335-GTG: (#EL4M)
    • Minimum required: 0
    • Maximum allowed: 4 (Initial order maximum: 4)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#ELD0) - 1TB 7.2k RPM 5xx SATA SFF-4 Disk Drive

1 TB 7200 rpm SATA 2.5-inch (SFF) disk drive (HDD) formatted in 512 byte sectors (5xx) mounted on a 2.5-inch SFF-4 carrier/tray. Drive is rated at 6Gb/s though actual performance is dependent upon multiple factors. Limitations: Drive does not fit in 2.5-inch (SFF-1, SFF-2, SFF-3) bays due to physical differences in carriers/trays. Drive does not support the SAS interfaces. 5xx drives can not be reformatted to 4k byte sectors (or vice versa).

  • Attributes provided: 1TB of disk storage
  • Attributes required: One SFF-4 bay
  • For 8335-GTG: (#ELD0)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#ELU4) - 960 GB 2.5-inch SATA/SSD Disk Drive
  • For 8335-GTG: (#ELU4)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#ELU5) - 1.92 TB 2.5-inch SATA/SSD Disk Drive
  • For 8335-GTG: (#ELU5)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#ELU6) - 3.84 TB 2.5-inch SATA/SSD Disk Drive
  • For 8335-GTG: (#ELU6)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EM61) - 16 GB DDR4 2666 RDIMM

Provides 16 GB 2666 Mhz DDR4 of system memory.

  • Attributes provided: 16 GB RDIMM memory
  • Attributes required: Available memory slot
  • For 8335-GTG: (#EM61)
    • Minimum required: 0
    • Maximum allowed: 16 (Initial order maximum: 16)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EM63) - 32 GB DDR4 2666 RDIMM

Provides 32 GB 2666 MHz DDR4 of system memory.

  • Attributes provided: 32 GB RDIMM memory
  • Attributes required: Available memory slot
  • For 8335-GTG: (#EM63)
    • Minimum required: 0
    • Maximum allowed: 16 (Initial order maximum: 16)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EM64) - 64 GB DDR4 2666 RDIMM

Provides 64 GB 2666 MHz DDR4 of system memory.

  • Attributes provided: 64 GB RDIMM memory
  • Attributes required: Available memory slot
  • For 8335-GTG: (#EM64)
    • Minimum required: 0
    • Maximum allowed: 16 (Initial order maximum: 16)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EN01) - 1m (3.3-ft), 10Gb E'Net Cable SFP+ Act Twinax Copper

1m (3.3-ft) copper active twinax Ethernet cable which supports Ethernet data transfer rates up to 10 Gb/s. The cable has a copper twinax transceiver on each end which is placed in an SFP+ port of an adapter and/or a switch. This cabling option can be a cost effective alternative to optical cable for short reach link high-speed connection.

  • Attributes provided: 10Gb/s copper active twinax Ethernet cable
  • Attributes required: One available SFP+ 10Gb/s Ethernet Port
  • For 8335-GTG: (#EN01)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required:
      • Red Hat Enterprise Linux
      • AIX 6.1 and 7.1 or later supported
      • IBM i 7.1 TR8 and 7.2 or later supported
      • Refer to Software Requirements for specific O/S levels supported
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EN02) - 3m (9.8-ft), 10Gb E'Net Cable SFP+ Act Twinax Copper

3m (9.8-ft) copper active twinax Ethernet cable which supports Ethernet data transfer rates up to 10 Gb/s. The cable has a copper twinax transceiver on each end which is placed in an SFP+ port of an adapter and/or a switch. This cabling option can be a cost effective alternative to optical cable for short reach link high-speed connection.

  • Attributes provided: 10Gb/s copper active twinax Ethernet cable
  • Attributes required: One available SFP+ 10Gb/s Ethernet Port
  • For 8335-GTG: (#EN02)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required:
      • Red Hat Enterprise Linux
      • AIX 6.1 and 7.1 or later supported
      • IBM i 7.1 TR8 and 7.2 or later supported
      • Refer to Software Requirements for specific O/S levels supported
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EN03) - 5m (16.4-ft), 10Gb E'Net Cable SFP+ Act Twinax Copper

5m (16.4-ft) copper active twinax Ethernet cable which supports Ethernet data transfer rates up to 10 Gb/s. The cable has a copper twinax transceiver on each end which is placed in an SFP+ port of an adapter and/or a switch. This cabling option can be a cost effective alternative to optical cable for short reach link high-speed connection.

  • Attributes provided: 10Gb/s copper active twinax Ethernet cable
  • Attributes required: One available SFP+ 10Gb/s Ethernet Port
  • For 8335-GTG: (#EN03)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required:
      • Red Hat Enterprise Linux
      • AIX 6.1 and 7.1 or later supported
      • IBM i 7.1 TR8 and 7.2 or later supported
      • Refer to Software Requirements for specific O/S levels supported
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EN0T) - PCIe2 LP 4-Port (10Gb+1GbE) SR+RJ45 Adapter

PCIe Gen2 x8 short Ethernet adapter supports Ethernet NIC (Network Interface Card) traffic. The adapter provides two 10 Gb SR optical ports and two 1 Gb RJ45 ports in a PCIe 8x short form adapter.

The 10Gb ports are SFP+ and include optical SR transceivers. The ports have LC Duplex type connectors and utilize shortwave laser optics and MMF-850nm fiber cabling. With 62.5 micron OM1, up to 33 meter length fiber cables are supported. With 50 micron OM2, up to 82 meter fiber cable lengths are supported. With 50 micron OM3 or OM4, up to 300 meter fiber cable lengths are supported.

For the 1Gb RJ45 ports, 4-pair CAT-5 Unshielded Twisted Pair (UTP) cable or higher is supported for distances of up to 100 meters. In addition to 1Gb (1000 Mb) networks, 100 Mb networks are also supported, but 10Mb networks are not supported.

#EN0S and #EN0T adapters are electronically identical. They are physically identical except #EN0S has a tail stock for full high PCIe slots and #EN0T has a tail stock for low profile slots. The CCIN is 2CC3 for both features.

Details for the ports include:

  • VIOS NIM and LINUX NETWORK INSTALL are supported.
  • IEEE 802.3ae (10GBASE-SR), IEEE 802.3ab (1000BASE-T GbE), IEEEu 802.3u (100BASE-T), 802.1p priority, 802.1Q VLAN tagging, 802.3x flow control, 802.3ad load-balancing and failover,
  • Link aggregation, IEEE 802.3ad 802.3
  • Message Signalling Interrupt MSI-X, MSI and support of legacy pin interrupts
  • Ether II and IEEE 802.3 encapsulated frames
  • Jumbo frames up to 9.6 Kbytes
  • TCP checksum offload for IPv4 and IPv6
  • TCP segmentation Offload (TSO) RSS (Receive Side Scaling) support for IPv4, IPv6 and UDP for IPv4 and IPv6
  • UDP checksum offload for IPv4 and IPv6
  • AIX, IBM i and Linux provide software iSCSI support through the adapter.
  • Attributes provided: Four ports - two 10Gb and two 1Gb E
  • Attributes required: PCIe Gen2 or Gen3 slot - low profile
  • For 8335-GTG: (#EN0T)
    • Minimum required: 0
    • Maximum allowed: 3 (Initial order maximum: 3)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EN0V) - PCIe2 LP 4-port (10Gb+1GbE) Copper SFP+RJ45 Adapter

PCIe Gen2 x8 short Ethernet adapter supports Ethernet NIC (Network Interface Card) traffic. The adapter provides two 10 Gb twinax copperl ports and two 1 Gb RJ45 ports in a PCIe 8x short form adapter.

The 10Gb ports are SFP+ and do not include a transceiver. Active Copper twinax cables up to 5 meter in length are supported such as provided by feature #EN01, #EN02 or #EN03. A transceiver is included with these cables. Note that SFP+ twinax copper is NOT AS/400 5250 twinax or CX4 or 10 GBase-T. Active cables differ from passive cables.

For the 1Gb RJ45 ports, 4-pair CAT-5 Unshielded Twisted Pair (UTP) cable or higher is supported for distances of up to 100 meters. In addition to 1Gb (1000 Mb) networks, 100 Mb networks are also supported, but 10Mb networks are not supported.

#EN0U and #EN0V adapters are electronically identical. They are physically identical except #EN0U has a tail stock for full high PCIe slots and #EN0V has a tail stock for low profile slots. The CCIN is 2CC3 for both features.

Details for the ports include:

  • VIOS NIM and LINUX NETWORK INSTALL are supported.
  • IEEE 802.3ae (10 GbE),IEEE 802.3ab (1000BASE-T GbE), 100BASE-T IEEEu, 802.1p priority, 802.1Q VLAN tagging, 802.3x flow control, 802.3ad load-balancing and failover,
  • Link aggregation, IEEE 802.3ad 802.3
  • Message Signalling Interrupt MSI-X, MSI and support of legacy pin interrupts
  • Ether II and IEEE 802.3 encapsulated frames
  • Jumbo frames up to 9.6 Kbytes
  • TCP checksum offload for IPv4 and IPv6
  • TCP segmentation Offload (TSO) for IPv4 and IPv6
  • UDP checksum offload for IPv4 and IPv6
  • AIX, IBM i and Linux provide software iSCSI support through the adapter.
  • Attributes provided: Four ports - two 10Gb and two 1Gb E
  • Attributes required: PCIe Gen2 or Gen3 slot - low profile
  • For 8335-GTG: (#EN0V)
    • Minimum required: 0
    • Maximum allowed: 3 (Initial order maximum: 3)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EP0K) - 16-core 2.60 GHz (3.09 GHz Turbo) POWER9
  • For 8335-GTG: (#EP0K)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#EP0M) - 20-core 2.0 GHz (2.87 GHz Turbo) POWER9
  • For 8335-GTG: (#EP0M)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#EPAJ) - Power Cord 2m (6.56-foot), Drawer to IBM PDU, 250V/16A
  • For 8335-GTG: (#EPAJ)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EPAL) - Power Cord 2.8m (9.18-foot), Drawer to IBM PDU, 250V/16A
  • For 8335-GTG: (#EPAL)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EPAM) - Power Cord 4.3m (14.10-foot), Drawer to IBM PDU, 250V/16A
  • For 8335-GTG: (#EPAM)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EPTH) - Horizontal PDU Mounting Hardware

This feature ships the hardware required to properly horizontally mount one #EPTG/EPTJ, #EPTK/EPTL, #EPTM/EPTN or #EPTP/EPTQ PDU in a 1U 19-inch rack. A 1U blank panel for the front of the rack for air-flow control is included.

Without this hardware, the PDU can be mounted vertically in the rack's side pockets, but can only be poorly mounted horizontally. The front end of the PDU will be firmly attached to the rear of the rack. But the front of the PDU will be unsupported toward the middle of the rack. Without this hardware, the unsupported end of the PDU will rest on the hardware mounted immediately below it. If that underlying hardware is removed from the rack there is no support for the PDU.

Important Note: This feature code is typically used for an MES order and not for an original order of a new rack with #EPTn PDUs. As part of factory integration, IBM Manufacturing automatically adds this hardware without a feature code and at no additional charge when its #EPTn PDU placement logic calls for horizontally mounted PDUs. Use this feature code when (1) converting an existing vertically mounted #EPTn PDU to horizontal mounting or (2) separately ordering a #EPTn PDU for horizontal field installation.

  • Attributes provided: mounting hardware
  • Attributes required: High Function PDU (#EPT*) and space in 19-inch rack
  • For 8335-GTG: (#EPTH)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EPTJ) - High Function 9xC19 PDU

Switched, Monitoring

This is an intelligent, switched 200-240 volt AC Power Distribution Unit (PDU) with nine C19 receptacles on the front of the PDU. The PDU is mounted on the rear of the rack making the nine C19 receptacles easily accessible. Each receptacle has a 20 amp circuit breaker. Depending on country wiring standards the PDU is single-phase or three-phase wye. See three-phase #EPTK/EPTL for countries which do not use wye wiring.

The PDU can be mounted vertically in rack side pockets or it can be mounted horizontally. If mounted horizontally, it uses 1 EIA (1U) of rack space. See feature #EPTH for horizontal mounting hardware.

Device power cords with a C20 plug connect to C19 PDU receptacles and are ordered separately. One country-specific wall line cord is also ordered separately and attaches to a UTG524-7 connector on the front of the PDU. Supported line cords include features #6489, #6491, #6492, #6653, #6654, #6655, #6656, #6657, #6658, and #6667.

Two RJ45 ports on the front of the PDU enable the client to monitor each receptacle's electrical power usage and to remotely switch any receptacle on or off. The PDU is shipped with a generic PDU password and IBM strongly urges clients to change it upon installation.

There are also three C13 receptacles on the rear of the PDU positioned toward the middle of the rack. These are generally not easily accessed and therefore IBM does not generally recommend their use.

#EPTG and #EPTJ are identical PDUs. Up to one lower price #EPTG can be ordered with a new 7014-T42/T00 rack in place of a no-charge #9188 PDU.

For comparison, this is most similar to the earlier generation #7189 PDU

  • Attributes provided: Nine C19 PDU - switched, power monitoring
  • Attributes required: PDU wall line cord & space in 19-inch rack
  • For 8335-GTG: (#EPTJ)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#EPTL) - High Function 9xC19 PDU 3-Phase

Switched, Monitoring

This is an intelligent, switched 208 volt 3-phase AC Power Distribution Unit (PDU) with nine C19 receptacles on the front of the PDU. The PDU is mounted on the rear of the rack making the nine C19 receptacles easily accessible. Each receptacle has a 20 amp circuit breaker.

The PDU can be mounted vertically in rack side pockets or it can be mounted horizontally. If mounted horizontally, it uses 1 EIA (1U) of rack space. See feature #EPTH for horizontal mounting hardware.

Device power cords with a C20 plug connect to C19 PDU receptacles and are ordered separately. One wall line cord is provided with the PDU (no separate feature code) and has a IEC60309 60A plug (3P+G). The PDU supports up to 48 amps.

Two RJ45 ports on the front of the PDU enable the client to monitor each receptacle's electrical power usage and to remotely switch any receptacle on or off. The PDU is shipped with a generic PDU password and IBM strongly urges clients to change it upon installation.

There are also three C13 receptacles on the rear of the PDU positioned toward the middle of the rack. These are generally not easily accessed and therefore IBM does not generally recommend their use.

#EPTK and #EPTL are identical PDUs. Up to one lower price #EPTK can be ordered with a new 7014-T42/T00 rack in place of a no-charge #9188 PDU.

For comparison, this is most similar to the earlier generation #7196 PDU.

  • Attributes provided: Nine C19 PDU - switched, power monitoring
  • Attributes required: space in rack, 3-phase 208V AC delta electrical service
  • For 8335-GTG: (#EPTL)
    • Minimum required: 0
    • Maximum allowed: 9999 (Initial order maximum: 250)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#ERB0) - Bulk Packaging Request ID

This indicator is used to optimize package density of 2U server shipments through the use of bulk packaging.

Note: Bulk packaging would be defaulted via a specify code on the order for any customer order that contains 4 or more servers.

Limitations: There will be no mixing of MTMs with in the bulk packaging.

  • Attributes provided: Bulk packaging from the IBM factory to the customer.
  • Attributes required: Order that contains 4 or more servers.
  • For 8335-GTG: (#ERB0)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None.
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ERB1) - Bulk Packaging ID #1

This indicator is used to specify that servers will be bulk packaged for shipment in package identifier #1.

Note: Bulk packaging would be defaulted via a specify code on the order for any customer order that contains 4 or more servers.

Limitations: There will be no mixing of MTMs with in the bulk packaging.

  • Attributes provided: Multiple servers in 1 package.
  • Attributes required: Order that contains 4 or more servers.
  • For 8335-GTG: (#ERB1)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None.
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ERB2) - Bulk Packaging ID #2

This indicator is used to specify that servers will be bulk packaged for shipment in package identifier #2.

Note: Bulk packaging would be defaulted via a specify code on the order for any customer order that contains 4 or more servers.

Limitations: There will be no mixing of MTMs with in the bulk packaging.

  • Attributes provided: Multiple servers in 1 package.
  • Attributes required: Order that contains 4 or more servers.
  • For 8335-GTG: (#ERB2)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None.
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ERB3) - Bulk Packaging ID #3

This indicator is used to specify that servers will be bulk packaged for shipment in package identifier #3.

Note: Bulk packaging would be defaulted via a specify code on the order for any customer order that contains 4 or more servers.

Limitations: There will be no mixing of MTMs with in the bulk packaging.

  • Attributes provided: Multiple servers in 1 package.
  • Attributes required: Order that contains 4 or more servers.
  • For 8335-GTG: (#ERB3)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None.
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ERB4) - Bulk Packaging ID #4

This indicator is used to specify that servers will be bulk packaged for shipment in package identifier #4.

Note: Bulk packaging would be defaulted via a specify code on the order for any customer order that contains 4 or more servers.

Limitations: There will be no mixing of MTMs with in the bulk packaging.

  • Attributes provided: Multiple servers in 1 package.
  • Attributes required: Order that contains 4 or more servers.
  • For 8335-GTG: (#ERB4)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None.
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ERB5) - Bulk Packaging ID #5

This indicator is used to specify that servers will be bulk packaged for shipment in package identifier #5.

Note: Bulk packaging would be defaulted via a specify code on the order for any customer order that contains 4 or more servers.

Limitations: There will be no mixing of MTMs with in the bulk packaging.

  • Attributes provided: Multiple servers in 1 package.
  • Attributes required: Order that contains 4 or more servers.
  • For 8335-GTG: (#ERB5)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None.
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ERB6) - Bulk Packaging ID #6

This indicator is used to specify that servers will be bulk packaged for shipment in package identifier #6.

Note: Bulk packaging would be defaulted via a specify code on the order for any customer order that contains 4 or more servers.

Limitations: There will be no mixing of MTMs with in the bulk packaging.

  • Attributes provided: Multiple servers in 1 package.
  • Attributes required: Order that contains 4 or more servers.
  • For 8335-GTG: (#ERB6)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None.
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ERB7) - Bulk Packaging ID #7

This indicator is used to specify that servers will be bulk packaged for shipment in package identifier #7.

Note: Bulk packaging would be defaulted via a specify code on the order for any customer order that contains 4 or more servers.

Limitations: There will be no mixing of MTMs with in the bulk packaging.

  • Attributes provided: Multiple servers in 1 package.
  • Attributes required: Order that contains 4 or more servers.
  • For 8335-GTG: (#ERB7)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None.
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ERB8) - Bulk Packaging ID #8

This indicator is used to specify that servers will be bulk packaged for shipment in package identifier #8.

Note: Bulk packaging would be defaulted via a specify code on the order for any customer order that contains 4 or more servers.

Limitations: There will be no mixing of MTMs with in the bulk packaging.

  • Attributes provided: Multiple servers in 1 package.
  • Attributes required: Order that contains 4 or more servers.
  • For 8335-GTG: (#ERB8)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None.
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ERB9) - Bulk Packaging ID #9

This indicator is used to specify that servers will be bulk packaged for shipment in package identifier #9.

Note: Bulk packaging would be defaulted via a specify code on the order for any customer order that contains 4 or more servers.

Limitations: There will be no mixing of MTMs with in the bulk packaging.

  • Attributes provided: Multiple servers in 1 package.
  • Attributes required: Order that contains 4 or more servers.
  • For 8335-GTG: (#ERB9)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None.
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ERBA) - Bulk Packaging ID #10

This indicator is used to specify that servers will be bulk packaged for shipment in package identifier #10.

Note: Bulk packaging would be defaulted via a specify code on the order for any customer order that contains 4 or more servers.

Limitations: There will be no mixing of MTMs with in the bulk packaging.

  • Attributes provided: Multiple servers in 1 package.
  • Attributes required: Order that contains 4 or more servers.
  • For 8335-GTG: (#ERBA)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None.
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ERBB) - Bulk Packaging ID #11

This indicator is used to specify that servers will be bulk packaged for shipment in package identifier #11.

Note: Bulk packaging would be defaulted via a specify code on the order for any customer order that contains 4 or more servers.

Limitations: There will be no mixing of MTMs with in the bulk packaging.

  • Attributes provided: Multiple servers in 1 package.
  • Attributes required: Order that contains 4 or more servers.
  • For 8335-GTG: (#ERBB)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None.
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ERBC) - Bulk Packaging ID #12

This indicator is used to specify that servers will be bulk packaged for shipment in package identifier #12.

Note: Bulk packaging would be defaulted via a specify code on the order for any customer order that contains 4 or more servers.

Limitations: There will be no mixing of MTMs with in the bulk packaging.

  • Attributes provided: Multiple servers in 1 package.
  • Attributes required: Order that contains 4 or more servers.
  • For 8335-GTG: (#ERBC)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None.
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ERBD) - Bulk Packaging ID #13

This indicator is used to specify that servers will be bulk packaged for shipment in package identifier #13.

Note: Bulk packaging would be defaulted via a specify code on the order for any customer order that contains 4 or more servers.

Limitations: There will be no mixing of MTMs with in the bulk packaging.

  • Attributes provided: Multiple servers in 1 package.
  • Attributes required: Order that contains 4 or more servers.
  • For 8335-GTG: (#ERBD)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None.
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ERBE) - Bulk Packaging ID #14

This indicator is used to specify that servers will be bulk packaged for shipment in package identifier #14.

Note: Bulk packaging would be defaulted via a specify code on the order for any customer order that contains 4 or more servers.

Limitations: There will be no mixing of MTMs with in the bulk packaging.

  • Attributes provided: Multiple servers in 1 package.
  • Attributes required: Order that contains 4 or more servers.
  • For 8335-GTG: (#ERBE)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None.
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ERBF) - Bulk Packaging ID #15

This indicator is used to specify that servers will be bulk packaged for shipment in package identifier #15.

Note: Bulk packaging would be defaulted via a specify code on the order for any customer order that contains 4 or more servers.

Limitations: There will be no mixing of MTMs with in the bulk packaging.

  • Attributes provided: Multiple servers in 1 package.
  • Attributes required: Order that contains 4 or more servers.
  • For 8335-GTG: (#ERBF)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None.
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ERBG) - Bulk Packaging ID #16

This indicator is used to specify that servers will be bulk packaged for shipment in package identifier #16.

Note: Bulk packaging would be defaulted via a specify code on the order for any customer order that contains 4 or more servers.

Limitations: There will be no mixing of MTMs with in the bulk packaging.

  • Attributes provided: Multiple servers in 1 package.
  • Attributes required: Order that contains 4 or more servers.
  • For 8335-GTG: (#ERBG)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None.
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ERBH) - Bulk Packaging ID #17

This indicator is used to specify that servers will be bulk packaged for shipment in package identifier #17.

Note: Bulk packaging would be defaulted via a specify code on the order for any customer order that contains 4 or more servers.

Limitations: There will be no mixing of MTMs with in the bulk packaging.

  • Attributes provided: Multiple servers in 1 package.
  • Attributes required: Order that contains 4 or more servers.
  • For 8335-GTG: (#ERBH)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None.
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ERBJ) - Bulk Packaging ID #18

This indicator is used to specify that servers will be bulk packaged for shipment in package identifier #18.

Note: Bulk packaging would be defaulted via a specify code on the order for any customer order that contains 4 or more servers.

Limitations: There will be no mixing of MTMs with in the bulk packaging.

  • Attributes provided: Multiple servers in 1 package.
  • Attributes required: Order that contains 4 or more servers.
  • For 8335-GTG: (#ERBJ)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None.
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ERBK) - Bulk Packaging ID #19

This indicator is used to specify that servers will be bulk packaged for shipment in package identifier #19.

Note: Bulk packaging would be defaulted via a specify code on the order for any customer order that contains 4 or more servers.

Limitations: There will be no mixing of MTMs with in the bulk packaging.

  • Attributes provided: Multiple servers in 1 package.
  • Attributes required: Order that contains 4 or more servers.
  • For 8335-GTG: (#ERBK)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None.
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ERBL) - Bulk Packaging ID #20

This indicator is used to specify that servers will be bulk packaged for shipment in package identifier #20.

Note: Bulk packaging would be defaulted via a specify code on the order for any customer order that contains 4 or more servers.

Limitations: There will be no mixing of MTMs with in the bulk packaging.

  • Attributes provided: Multiple servers in 1 package.
  • Attributes required: Order that contains 4 or more servers.
  • For 8335-GTG: (#ERBL)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None.
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ERBZ) - No Bulk Packaging Specify

This indicator is used to indicate single packaging will be used and not allow for bulk packaging.

  • Attributes provided: Single packages
  • Attributes required: Customer orders fewer than 4 servers
  • For 8335-GTG: (#ERBZ)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None.
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ERF1) - RFID Tags for Servers, Compute Nodes, Chassis, Racks, and HMCs

The specify feature attaches one Radio Frequency Identification Device (RFID) tag to a Server CEC, rack, HMC, compute node, or chassis enclosure. This can be used with MTM (machine type model) rack such as a 7953-94X or 7014-T42, not a feature code rack such as a #0553. It applies to newly shipped MTM servers, racks, HMCs, compute nodes, and chassis enclosures, not MES orders with one exception. POWER5 CECs being upgraded to a POWER6 CEC or POWER6 CECs being upgraded to a POWER 7 CEC can order this feature. The RFID tag meets the Financial Services Technology Consortium (FSTC) specifications for IT Data Center Asset Tracking.

  • Attributes provided: RFIDs
  • Attributes required: Server CEC, Compute Node, Chassis, MTM Rack, or HMC
  • For 8335-GTG: (#ERF1)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required:
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#ES6A) - 2 TB 7.2k RPM 5xx SATA SFF-4 Disk Drive

2 TB 7200 rpm SATA 2.5-inch (SFF) disk drive (HDD) formatted in 512 byte sectors (5xx) mounted on a 2.5-inch SFF-4 carrier/tray. Drive is rated at 6Gb/s though actual performance is dependent upon multiple factors.

Limitations: Drive does not fit in 2.5-inch (SFF-1, SFF-2, SFF-3) bays due to physical differences in carriers/trays. Drive does not support the SAS interfaces. 5xx drives can not be reformatted to 4k byte sectors (or vice versa).

  • Attributes provided: 2 TB of disk storage
  • Attributes required: One SFF-4 bay
  • For 8335-GTG: (#ES6A)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No
(#ESC0) - S&H - No Charge

No charge shipping and handling

  • Attributes provided: None
  • Attributes required: Sales Preapproval Required
  • For 8335-GTG: (#ESC0)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Both
    • CSU: N/A
    • Return parts MES: Does not apply
(#ESC5) - S&H-a

Shipping and handling

  • Attributes provided: None
  • For 8335-GTG: (#ESC5)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required: None
    • Initial Order/MES/Both/Supported: Initial
    • CSU: N/A
    • Return parts MES: Does not apply
(#EUA5) - Standalone USB DVD drive w/cable
  • For 8335-GTG: (#EUA5)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • OS level required:
    • Initial Order/MES/Both/Supported: Both
    • CSU: Yes
    • Return parts MES: No

Back to topBack to top
 
Accessories

None.

Customer replacement parts

The following parts and feature(s) have been designated as Tier 1 CRUs:

  • Hard disk drive
  • Optical drive
  • Fan
  • Fan Cage
  • I/O adapters
  • Operator panel
  • Operator panel cable
  • PCI adapters
  • Power cord
  • Power supply
  • Processor power regulator
  • Service processor
  • RAID card cable
  • Memory DIMMs
  • Native USB Serial Card
  • Keyboard
  • Mouse
  • External cables
  • Display
  • Sheet metal trays and dividers
  • Planar
  • Air duct
  • Heat sinks
  • Rails

Back to topBack to top
 
Supplies

None.

Supplemental media

None.

Trademarks

(R), (TM), * Trademark or registered trademark of International Business Machines Corporation.

** Company, product, or service name may be a trademark or service mark of others.
 © IBM Corporation 2018.
Back to topBack to top

Contact IBM

Feedback