Family 8205+03 IBM Power 740 Express
IBM Europe Sales ManualRevised: October 09, 2018.
|
|
| Product life cycle dates |
|
|
| Type Model | Announced | Available | Marketing Withdrawn | Service Discontinued |
|---|---|---|---|---|
| 8205-E6D | 2013/02/05 | 2013/02/20 | 2015/11/30 | - |
|
|
| Abstract |
|
|
The IBM 8205 is the Power 740 Express server that can enable companies to spend more time running their business, using proven solutions from thousands of ISVs that support the AIX, IBM i, and Linux operating systems. The new Power 740 model (8205-E6D) includes enhancements that can be particularly beneficial to clients running applications that drive very high I/O or memory requirements.
Model abstract 8205-E6D
The IBM 8205 Power 740 Express server Model E6D has a POWER7+
processor, 8 GB minimum, 1024 GB maximum memory, 7.2 TB HDD/SSD, 6
slots, 8 2.5" SFF bays and two media bays.
Back to top
|
|
| Highlights |
|
|
The Power 740 Express server is designed to bring the performance and reliability capabilities of POWER7+ to your small, midsized, or distributed business needs. The Power 740 Express model 8205-E6D offers:
- Powerful 64-bit POWER7+ processors that offer 6-, 8-, 12-, and 16-core configuration options
- Increased memory capacity; up to 1024 GB of memory with optional memory riser card, optionally augmented with POWER7+ hardware accelerated Active Memory Expansion
- Up to four optional PCIe I/O drawers adding up to 40 PCIe slots
- Rich I/O options in the system unit:
- Five PCIe Gen2 x8 slots in the system unit
- 4-port 1 Gb Ethernet adapter standard in a special x4 slot
- Additional four PCIe Gen2 x8 low-profile slots available as an option
- Eight hard disk drive (HDD)/solid-state drive (SSD) SAS small form factor (SFF) bays; up to 7.2 TB (HDD) or 4.8 TB (SSD)
- Optional slimline DVD-RAM
- Half-high bay for tape or removable drive
- Integrated SAS/SATA controller for HDD/SSD/tape/DVD with RAID 10
- 4-pack and 6-pack SSD features that can be ordered with a new server
- EnergyScale technology
Certain configurations of Power 740 are ENERGY STAR qualified. Refer to
- Rack-mount configuration
|
|
| Description |
|
|
As a distributed application server, the Power 740 Express is designed to deliver leading-edge application availability and enable more work to be processed with less operational disruption for branch office and in-store applications. As consolidation servers, PowerVM Editions offer the flexibility to use leading-edge AIX, IBM i, and Linux applications. PowerVM Editions deliver comprehensive virtualization technologies designed to aggregate and manage resources while helping to simplify and optimize your IT infrastructure and deliver one of the most cost-efficient solutions for UNIX, IBM i, and Linux deployments.
The Power 740 Express server with IBM i offers a technology foundation with proven reliability and security for the small or midsized company seeking a complete, integrated business system. This business system enables you to avoid increased spending and staffing requirements while becoming more responsive to your customers, improving your productivity, and keeping your data secure. IBM i integrates features to simplify your IT environment and delivers a complete, cost-effective business system that can grow with a business. The Power 740 delivers the performance and capacity to run new and existing core business applications on a single server, to greatly integrate and simplify your IT environment.
The Power 740 Express offers the following POWER7+ processor module configurations in a 4U rack-mount form factor:
- 6-core or 12-core 4.2 GHz
- 8-core or 16-core 3.6 GHz or 4.2 GHz
The Power 740 Express server supports a maximum of 32 DDR3 DIMM slots, with eight DIMM slots included in the base configuration and 24 DIMM slots available with three optional memory riser cards. Memory features (two memory DIMMs per feature) supported are 8 GB, 16 GB, 32 GB, and 64 GB that run at speeds of 1066 MHz. A system with three optional memory riser cards installed has a maximum memory of 1024 GB. The POWER7+ hardware accelerator for Active Memory Expansion offers 25% higher levels of memory expansion than available with POWER7 chips. While POWER7 Systems offer up to 100% memory expansion that can effectively double the server's maximum memory, POWER7+ servers offer up to 125% memory expansion for AIX partitions. Thus, a system memory maximum of 1024 GB could effectively become greater than 2 TB effective memory capacity. This can enhance virtualization and server consolidation by enabling a partition to do significantly more work with the same physical amount of memory or a server to run more partitions and do more work with the same physical amount of memory.
The Power 740 Express server delivers increased I/O expandability. For example, with 12X-attached I/O drawers, you can have up to 40 PCIe slots in addition to the PCI slots in the system unit. Using disk bays in the system unit, 12X feature 5802 I/O drawers, and feature 5886 EXP12S Expansion Drawers or feature 5887 EXP24S Gen2 Expansion Drawers, up to 416 HDDs or SSDs can be attached. Plus extensive quantities of externally attached storage and tape drives and libraries can be attached.
Two SSD packages offer ordering convenience and price savings for a new server order. Each 6-pack SSD feature #ESR2/#ESR4 for the EXP30 Ultra SSD I/O Drawer can enable up to 140,000 I/O operations per second (IOPS) in just 1/5th of a 1U drawer. The 4-pack SSD feature #ESRA/ESRB/ESRC/ESRD can enable up to 90,000 IOPS. You must order a 6-pack or 4-pack SSD with the server, not as a later MES order.
The Power 740 Express system offers two storage backplanes. The first supports up to six SFF SAS HDDs/SSDs, an SATA DVD, and a half- high tape drive. The second is a higher-function backplane that supports up to eight SFF SAS HDDs/SSDs, an SATA DVD, a half-high tape drive, dual 175 MB write cache RAID, and an external SAS port. HDDs and SSDs are hot-swap and front accessible.
Other integrated features include:
- Up to 10 PCIe Gen2 expansion slots
- Five PCIe Gen2 x8 expansion slots
- Four additional PCIe Gen2 x8 low-profile slots (optional)
- Two GX++ slots used to attach:
- PCIe riser card for the four additional PCIe Gen2 x8 slots
- 12X I/O loop
- EXP30 Ultra SSD I/O Drawer (#EDR1)
- One PCIe x4 expansion slot for 4-port 1 Gb Ethernet adapter (#5899)
- Service Processor
- Integrated SAS/SATA controller for HDD,SSD, tape, DVD with RAID 10 in system unit; RAID 5 and 6 available
- EnergyScale technology
- Two system ports and three USB ports
- Two Hardware Management Console (HMC) ports and two System Power Control Network (SPCN) ports
- Redundant and hot-swap power and hot-swap cooling available
The Power 740 Express (8205-E6D) model is particularly recommended when a solution requires fast communications or I/O, or requires the maximum amount of memory available. PCIe Gen2 slots can transfer data at double the speed of many earlier servers which only offered PCIe Gen1 slots. The high data transfer rates offered by the PCIe Gen2 slots can enable higher I/O performance or consolidation of the I/O demands onto fewer adapters running at higher rates. This can result in better system performance at a lower cost when I/O demands are high.
Summary of standard features for Power 740:
- 6-and 8-core POWER7+ processor modules, offering the following
configurations:
- 6-core or 12-core 4.2 GHz
- 8-core or 16-core 3.6 GHz or 4.2 GHz
- 8, 16, 32, or 64 GB of 1066 MHz DDR3 ECC memory (error checking and correcting) memory, expandable to 1024 GB
- 6 x 2.5-inch HDD or SSD/Media backplane or 8 x 2.5-inch HDD or
SSD/Media backplane with dual 175 MB write cache RAID, and an external
SAS port
- One to eight SFF HDDs or SSDs (mixing allowed)
- Two media bays:
- One slim bay for an optional DVD-RAM
- One half-high bay for an optional tape drive or removable disk
- Maximum of five PCIe Gen2 x8 slots in base configuration plus:
- Sixth PCIe Gen2 x4 slot for an Ethernet adapter
- Optional PCIe riser card enabling an additional four PCIe Gen2 x8 low-profile slots
- One GX++ slot per processor module installed for I/O loop, unless the PCIe riser card is installed in the system, in which case the number of GX++ adapters that can be installed in the CEC is reduced by one
- Integrated:
- Service Processor
- EnergyScale technology
- Hot-swap and redundant cooling
- Three USB ports; two system ports
- Two HMC ports; two SPCN ports
- Two power supplies, 1925 watt ac
- Rack-mount (4U) configuration
Certain configurations of Power 740 are ENERGY STAR qualified. Refer to
Two SSD packages offer ordering convenience and price savings for a server. One 6-pack SSD feature #ESR2/ESR4 orders the equivalent of six #ES02/ES04 387 GB SSDs for the #EDR1 EXP30 Ultra SSD I/O Drawer, but has a lower price. Multiple 6-pack features can be ordered with a new server. 6-pack features and single SSD features can be combined in the same Ultra SSD Drawer.
One 4-pack SSD features orders the equivalent of four 387 GB SSDs for SAS bays in a system unit or in an I/O drawer, but has a lower price compared to ordering four #ES0A/ES0B/ES0C/ES0D features. A maximum of one 4-pack feature (#ESRA/ESRB/ESRC/ESRD) can be ordered with a new server. 4-pack features and single SSD features can be combined in the same system.
The minimum Power 740 initial order must include a processor, processor activations, 8 GB of memory, two power supplies, a PCIe2 4-port GbE adapter, two power cords, one HDD/SSD, a storage backplane, an operating system indicator, a cover set indicator, and a Language Group Specify.
If IBM i is the primary operating system (#2145), the initial order must also include one additional HDD/SSD, a Mirrored System Disk Level Specify Code, and a System Console on HMC Indicator. A DVD is defaulted on every order but may be unselected.
The minimum defined initial order configuration, if no choice is made, when AIX or Linux is the primary operating system is:
Feature number Description
-------------- ----------------------------------------------------
EPCP 0/6 core 4.2 GHz POWER7+ Processor
EPDP x 6 6 Processor Activations
EM08 8 GB (2 x 4096 MB) Memory
1886 146.8 GB 15k rpm, SFF HDD
5618 Storage Backplane for 2.5-inch HDD or SSD/SATA
DVD/Tape
5899 PCIe2 4-port 1 GbE Adapter
5532 x 2 Power supply, 1925 watt ac
7131 IBM Rack-mount Drawer Bezel and Hardware
9300/97xx Language Group Specify
2146 or 2147 Primary Operating System Indicator - IBM AIX (#2146)
or Linux (#2147)
6xxx x 2 Two power cords
Note: No internal HDD or SSD is required if feature 0837 (Boot from SAN) is selected. A Fibre Channel or Fibre Channel over Ethernet (FCoE) adapter must be ordered if feature 0837 is selected.
The minimum defined initial order configuration, if no choice is made, when IBM i is the primary operating system is:
Feature number Description
-------------- ----------------------------------------------------
EPCP 0/6 core 4.2 GHz POWER7+ Processor
EPDP x 6 6 Processor Activations
EM08 8 GB (2 x 4096 MB) Memory
1888 x 2 139.5 GB, 15k rpm, SAS SFF HDD
EJ01 Storage Backplane for 2.5-inch HDD or SSD/SATA
DVD/Tape/RAID/External SAS Port
5899 PCIe2 4-port 1 GbE Adapter
5532 x 2 Power supply, 1925 watt ac
7131 IBM Rack-mount Drawer Bezel and Hardware
9300/97xx Language Group Specify
2145 Primary Operating System Indicator - IBM i
0040 Mirrored System Disk Level Specify Code
0566 or 0567 IBM i 6.1.1 or IBM i 7.1 indicator or
EB34 IBM i 6.1.1 with IBM i 6.1.1 native I/O indicator
5550 or 5557 System Console on HMC Indicator or
System Console-Ethernet No IOP
6xxx x 2 Two power cords
Note: Planned availability of IBM i 6.1.1 is March 8, 2013.
Note: No internal HDD/SSD is required if feature 0837 (Boot from SAN) is selected. A Fibre Channel adapter must be ordered if feature 0837 is selected.
Note: When IBM i is the primary operating system (#2145), a DVD-ROM or DVD-RAM must be accessible by the Power 740.
Note: Alternative configuration options are available on a special bid basis from your IBM representative or Business Partner.
IBM Editions
IBM Editions are available only as initial order.
If you order a Power 740 Express server IBM Edition as defined below, you can qualify for half the initial configuration's processor core activations at no additional charge.
The total memory (based on the number of cores) and the quantity/size of disk, SSD, Fibre Channel adapters, or FCoE adapters shipped with the server are the only features that determine if a client is entitled to a processor activation at no additional charge.
Specifically, with an IBM Edition, processor activations for the processor card options are:
- One or two 4.2 GHz 6-core processor modules (#EPCP)
- 3 x #EPDP (chargeable) and 3 x #EPEP (no-charge) per #EPCP 6-core processor module
- One or two 3.6 GHz 8-core processor modules (#EPCQ)
- 4 x #EPDQ (chargeable) and 4 x #EPEQ (no-charge) per #EPCQ 8-core processor module
- One or two 4.2 GHz 8-core processor modules (#EPCR)
- 4 x #EPDR (chargeable) and 4 x #EPER (no-charge) per #EPCR 8-core processor module
Note: The Power 740 (8205-E6D) contains either one or two processor modules. IBM Editions are available on the Power 740 with either one or two processor modules.
When you purchase an IBM Edition, you must purchase an AIX or IBM i operating system license, or you may choose to purchase the system with or without a Linux operating system. The AIX, IBM i, or Linux operating system is processed via a feature number on AIX 6.1 or 7.1; IBM i 6.1.1 or IBM i 7.1; and SUSE Linux Enterprise Server or Red Hat Enterprise Linux. If you choose AIX 6.1 or 7.1 for your primary operating system, you can also order IBM i 6.1.1 or IBM i 7.1 and SUSE Linux Enterprise Server or Red Hat Enterprise Linux. The converse is true if you choose an IBM i or Linux subscription as your primary operating system.
These sample configurations can be changed as needed and still qualify for processor entitlements at no additional charge. However, selecting total memory, HDD, or SSD/Fibre Channel/FCoE adapter quantities smaller than the totals defined as the minimums disqualifies the order as an IBM Edition, and the no-charge processor activations are then removed.
Processor modules and processor activations are available only to Solution Delivery Integration (SDIs) as MES orders.
IBM Edition minimum memory definition details
A minimum of 4 GB memory per core is needed to qualify for the IBM Edition. For example, a 6-core minimum is 24 GB, and an 8-core minimum is 32 GB. Different valid memory configurations meet the minimum requirement: a minimum of two HDD, two SSD, or two Fibre Channel adapters, or two FCoE adapters. You only need to meet one of these disk, SSD, Fibre Channel, or FCoE criteria. Partial criteria cannot be combined.
- Two SAS HDDs: Any capacity drives located in the system unit, features 5802, 5886, or 5887 DASD drawers qualify.
- Two SAS SSDs: Any capacity drives located in the system unit, features EDR1, 5802, 5886, or 5887 DASD drawers qualify.
- Two SSD modules with eMLC (#1995/#1996): Modules located in the system unit with feature 2053 or 2054, or in feature 5802 or 5887 DASD drawer with feature 2055 qualify.
- Two Fibre Channel adapters: Either PCI-X or PCI-e adapters located in the system unit or 12X-attached I/O drawer.
- Two Fibre Channel over Ethernet adapters: Located in the system unit or PCIe 12X-attached I/O drawer.
Multiple sample POWER7+ IBM Edition configurations are provided in the IBM internal configurator tool, including:
- 4.2 GHz 6-core processor module
- 3.6 GHz 8-core processor module
- 4.2 GHz 8-core processor module
IBM POWER 710 AIX SOLUTION EDITION
If you order an IBM Power 740 AIX Solution Edition server as defined below, you can qualify for half of the initial configuration's processor core activations at no additional charge, and reduced charges for AIX Standard Edition license activations.
The IBM AIX Solution Editions are designed to help you take advantage of the combined experience and expertise of IBM and ISVs in building business value with your IT investments. A qualifying purchase of software for an eligible solution from a participating ISV is required when purchasing an IBM AIX Solution Edition.
The Power 740 AIX Solution Edition supports 6-16 core configurations. For a list of participating ISVs and their eligible solutions, registra-tion form, and additional details, visit the Solution Edition website at
http://www.ibm.com/systems/power/hardware/solutioneditions/aix/index.html
The Power 740 AIX Solution Edition includes no-charge and reduced- charge features, resulting in a lower initial list price for qualifying clients.
The requirements to be eligible to place a Power 740 AIX Solution Edition order are:
- The solution must include new licenses of AIX for the qualifying IBM server.
- The solution must meet the minimum memory and storage requirements as defined below.
- The solution must include PowerVM Standard Edition or PowerVM Enterprise Edition.
- The offering must include new or upgrade software licenses of an el-igible solution from the participating ISV for the qualifying IBM server.
- Proof of purchase of the solution with a participating ISV must be provided to IBM on request. The proof must be dated within 90 days before or after the date of order of the qualifying server.
IBM Power 740 AIX Solution Edition minimum memory definition details:
A minimum of 4 GB memory per core on the Power 740 is needed to qualify for the IBM AIX Solution Edition. There can be different valid memory configurations that meet the minimum requirement.
EDITION MINIMUM DISK/SSD/FIBRE CHANNEL/FCOE DEFINITION DETAILS
The order must meet one of these HDD/SSD/FC/FCoE criteria. Partial criteria cannot be combined.
- A minimum of two HDDs or two SSDs.
- Two SAS HDDs -- Any capacity drives located in the system unit, feature 5802 drawer, feature 5886 DASD drawer, or feature 5887 DASD drawer qualify.
- Two SAS SSDs -- Any capacity drives located in the system unit, feature 5886 DASD drawer, feature 5887 DASD drawer, or EDR1 SSD drawer qualify.
- Two SSD Modules with eMLC (#1995/#1996) -- Modules located in the system unit with feature 2053 qualify.
or
- A minimum of two Fibre Channel adapters, or two FCoE adapters for
attachment of a Storwize V7000 Storage System.
- Two Fibre Channel PCIe adapters located in the system unit.
- Two Fibre Channel over Ethernet PCIe adapters located in the system unit.
IBM i Solution Edition for Power 740
The IBM i Solution Editions are designed to help you take advantage of the combined experience and expertise of IBM and ISVs in building business value with your IT investments. A qualifying purchase of software, maintenance, services, or training for a participating ISV solution is required when purchasing an IBM i Solution Edition.
The Power 740 IBM i Solution Edition (#4929) supports 6-to 16-core configurations. For a list of participating ISVs, registration form, and additional details, visit the Solution Edition website at
http://www-03.ibm.com/systems/power/hardware/editions/solutions.html
The Power 740 IBM i Solution Edition includes no-charge features, resulting in a lower initial list price for qualifying clients. Also included is an IBM Service voucher to help speed implementation of the ISV solution.
The requirements to be eligible to purchase a 740 IBM i Solution Edition order are:
- The offering must include new or upgrade software licenses or software maintenance from the ISV for the qualifying IBM server. Services or training for the qualifying server can also be provided.
- Proof of purchase of the solution with a participating ISV must be provided to IBM on request. The proof must be dated within 90 days before or after the date of order of the qualifying server.
Dynamic logical partitioning
The dynamic logical partitioning (LPAR) function includes enhanced resource management for the Power 740 Express server. Dynamic LPAR enables available system resources to be quickly and easily configured across multiple logical partitions to meet the rapidly changing needs of your business.
Dynamic LPAR also enables you to add new system resources such as new HDDs or SSDs into your system's configuration without requiring a reboot. With the PowerVM Express (#5225) feature, three LPARs are supported in a 16-core Power 740. If the PowerVM Standard (#5227) or Enterprise Edition (#5228) feature is installed in the system, a maximum of 20 dynamic LPARs for each physical processor core can be defined, with a system maximum of 320 dynamic LPARs.
An HMC or Integrated Virtualization Manager (IVM) is required to manage the Power 740 (8205-E6D) implementing partitioning. Multiple Power 740 servers can be supported by a single HMC.
If an HMC is used to manage any Power 740 server, the HMC must be a rack-mount HMC model CR3, or later, or deskside HMC model C05, or later.
When IBM Systems Director is used to manage an HMC or if the HMC manages more than 254 partitions, the HMC should have 3 GB of RAM minimum and be the rack-mount model CR3, or later, or deskside model C06, or later.
PowerVM Editions (optional)
Three optional PowerVM Edition features are now available on the Power 740: PowerVM Express Edition, PowerVM Standard Edition, and PowerVM Enterprise Edition. These are managed using built-in IVM software or optionally through use of an HMC.
PowerVM Standard Edition (#5227) and PowerVM Enterprise Edition (#5228) enable you to create partitions in units of less than 1 CPU (sub-CPU LPARs) and enable the same system I/O to be virtually added to these partitions. The optional features, available for a fee, also include a software component that provides cross-partition workload management.
PowerVM Standard and Enterprise Editions offer:
- Micro-Partitioning (up to 20 partitions per processor core, 320 per system)
- Virtualized disk and optical devices (VIOS)
- Automated CPU reconfiguration
- Real-time partition configuration and load statistics
- Support for dedicated and shared processor LPAR groups
- Support for manual provisioning of resources
At initial order entry, selecting feature number 5227 or 5228 will result in Micro-Partitioning to be enabled during manufacture and the enabling software media and publications to be shipped to the client. When ordering feature number 5227 or 5228 as an MES, an activation key will be posted on an IBM website, and the client must retrieve it and install it on the system.
The IBM website is
Other features of PowerVM Editions:
- If any processors in a system have the Virtualization feature, all active processors must have it.
- Once the Virtualization feature is installed in a system, it cannot be removed.
- Virtual Ethernet and Virtual Storage are part of PowerVM Editions.
PowerVM Enterprise Edition also includes Live Partition Mobility, which allows for the movement of a logical partition from one POWER6 or POWER7 server to another with no application downtime, and Active Memory Sharing, which dynamically reallocates memory between running logical partitions on a server. Also available is PowerVM Express (#5225), designed for users looking for an introduction to more advanced virtualization features at a highly affordable price. With PowerVM Express and IVM, users can create up to three partitions on the server, leverage VIOS, utilize Shared Dedicated Capacity to help optimize use of processor cycles, and even try out the Shared Processor Pool. With its intuitive browser-based interface, IVM is easy to use and helps reduce the time and effort required to manage virtual devices, processors, and partitions. An HMC is not required.
You can upgrade from PowerVM Express to either PowerVM Standard or PowerVM Enterprise, or from PowerVM Standard to PowerVM Enterprise.
By upgrading to PowerVM Standard or PowerVM Enterprise, you can create up to 320 logical partitions on the Power 740. You can also manage your PowerVM enabled machine with either an HMC or the IVM.
By upgrading to PowerVM Enterprise, you can leverage Live Partition Mobility and Active Memory Sharing.
Power 740 Capacity BackUp (CBU) capability
(Applies to IBM i only)
The Power 740 system's CBU designation can help meet your requirements for a second system to use for backup, high availability, and disaster recovery. It enables you to temporarily transfer IBM i processor license entitlements and 5250 Enterprise Enablement entitlements purchased for a primary machine to a secondary CBU-designated system. Temporarily transferring these resources instead of purchasing them for your secondary system may result in significant savings. Processor activations cannot be transferred.
The CBU specify feature 0444 is available only as part of a new server purchase. Certain system prerequisites must be met and system registration and approval are required before the CBU specify feature can be applied on a new server. Standard IBM i terms and conditions do not allow either IBM i processor license entitlements or 5250 OLTP (Enterprise Enablement) entitlements to be transferred permanently or temporarily. These entitlements remain with the machine they were ordered for. When you register the association between your primary and on-order CBU system, you must agree to certain terms and conditions regarding the temporary transfer.
After a CBU system designation is approved and the system is installed, you can temporarily move your optional IBM i processor license entitlement and 5250 Enterprise Enablement entitlements from the primary system to the CBU system when the primary system is down or while the primary system processors are inactive. The CBU system can then better support failover and role swapping for a full range of test, disaster-recovery, and high-availability scenarios. Temporary entitlement transfer means that the entitlement is a property transferred from the primary system to the CBU system and may remain in use on the CBU system as long as the registered primary and CBU systems are in deployment for the high-availability or disaster- recovery operation.
The primary system for a Power 740 (8205-E6D) server with its P20 software tier can be:
- Power 740: 8205-E6B, 8205-E6C, 8205-E6D
- Power 750: 8233-E8B, 8408-E8D
- Power 760: 9109-RMD
- Power 770: 9117-MMB, 9117-MMC, 9117-MMD
- Power 550: 9409-M50, 8204-E8A
- Power 560: 8234-EMA
- Power 570: 9406-MMA, 9117-MMA
These systems have IBM i software licenses with an IBM i P20 or P30 software tier. The primary machine must be in the same enterprise as the CBU system.
Before you can temporarily transfer IBM i processor license entitlements from the registered primary system, you must have more than one IBM i processor license on the primary machine and at least one IBM i processor license on the CBU server. An activated processor must be available on the CBU server to use the transferred entitlement. You can then transfer any IBM i processor entitlements above the minimum one, assuming the total IBM i workload on the primary system does not require the IBM i entitlement you would like to transfer during the time of the transfer. During this temporary transfer, the CBU system's internal records of its total number of IBM i processor license entitlements are not updated, and you may see IBM i license noncompliance warning messages from the CBU system. These warning messages in this situation do not mean you are not in compliance.
Before you can temporarily transfer 5250 entitlements, you must have more than one 5250 Enterprise Enablement entitlement on the primary server and at least one 5250 Enterprise Enablement entitlement on the CBU system. You can then transfer the entitlements that are not required on the primary server during the time of transfer and that are above the minimum of one entitlement.
For example, if you have a 12-core Power 740 as your primary system with six IBM i processor license entitlements (five above the minimum) and two 5250 Enterprise Enablement entitlements (one above the minimum), you can temporarily transfer up to five IBM i entitlements and one 5250 Enterprise Enablement entitlement. During the temporary transfer, the CBU system's internal records of its total number of IBM i processor entitlements are not updated, and you may see IBM i license noncompliance warning messages from the CBU system.
Note that if the Power 740 CBU server has just one partition and if it is using the default parameters set by IBM Manufacturing, the IBM i licensing manager will ignore the temporary transfer and will not use additional processor cores. To work around this restriction for valid CBU situations, you can add a partition with no resource on your server or implement a shared processor pool.
If your primary or CBU machine is sold or discontinued from use, any temporary entitlement transfers must be returned to the machine on which they were originally acquired. For CBU registration and further information, visit
I/O drawer availability
Four 12X attached I/O drawers are supported on the Power 740, offering extensive overall server expandability and connectivity.
- Feature 5802 provides 10 PCIe slots and 18 SFF SAS DASD slots.
- Feature 5877 provides 10 PCIe slots.
- Feature 5796 provides six PCI-X slots (supported but not orderable).
- The 7314-G30 provides six PCI-X slots (supported but not orderable).
Three disk-only I/O drawers are also supported, offering large storage capacity and multiple partition support:
- Feature 5886 EXP12S holds twelve 3.5-inch SAS HDDs or SSDs (supported but not orderable).
- Feature 5887 EXP24S holds twenty-four 2.5-inch (SFF) SAS HDDs or SSDs.
- Feature EDR1 EXP30 holds 30 SSDs and two integrated SAS adapters
Feature number I/O drawers available for the Power 740
PCI-X DDR 12X Expansion Drawer (#5796) (supported only -- not orderable)
The PCI-X DDR 12X Expansion Drawer (#5796) is a 4 EIA unit tall drawer and mounts in a 19-inch rack. Feature 5796 is 22.35 cm (8.8 in) wide and takes up half the width of the 4 EIA rack space. Feature 5796 requires the use of a feature 7314 drawer-mounting enclosure. The 4 EIA tall enclosure can hold up to two feature 5796 drawers mounted side by side in the enclosure. The PCI-DDR 12X Expansion Drawer has six 64-bit, 3.3 V, PCI-X DDR slots running at 266 MHz that use blind-swap cassettes and support hot plugging of adapter cards. The drawer includes redundant hot-plug power and cooling. You must select one of the two available interface adapters for use in the feature 5796 drawer, either the Dual-Port 12X Channel Attach Adapter -- Long Run (#6457) or the Dual-Port 12X Channel Attach Adapter Short Run (#6446). The adapter selection is based on how close the host system or the next I/O drawer in the loop is physically located.
A maximum of four feature 5796 drawers can be placed on the same 12X loop. Mixing features 5802 or 5877 and 5796 on the same loop is not supported. Mixing feature 5796 and the 7314-G30 on the same loop is supported with a maximum of four drawers total per loop. A minimum configuration of two 12X cables (either SDR or DDR) and two ac power cables and two SPCN cables is required to ensure proper redundancy. The drawer attaches to the host CEC enclosure with a 12X adapter in a GX slot via 12X SDR or DDR cables.
The Power 740 uses the GX++ Dual-port 12x Channel Attach (#EJ04) adapter to attach a feature 5796 12X I/O Drawer using SDR speed.
PCI-X DDR 12X Expansion Drawer (7314-G30) (supported, not orderable)
The 7314-G30 is equivalent to the feature 5796 described above with one key difference: IBM i does not support this I/O drawer. Otherwise, it includes the same six PCI-X DDR slots per unit and has the same configuration rules and considerations as feature 5796.
12X I/O Drawer PCIe, SFF disk (#5802)
This feature provides a 4U high, 19-inch I/O drawer containing 10 PCIe 8x I/O adapter slots and 18 SAS hot-swap SFF SAS disk bays, which can be used for either disk drives or SSDs. Using 600 GB disk drives, the feature 5802 delivers up to 10.8 TB of storage.
The 18 disk bays can be organized either into one group of 18 bays (AIX or Linux), two groups of nine slots (AIX, IBM i, or Linux), or four groups of four or five bays (AIX or Linux). Selecting either one, two, or four groups of drive bays is done with a mode switch on the drawer.
A maximum of two feature 5802 drawers can be placed on the same 12X loop. Mixing feature 5802 and feature 5796 and the 7314-G30 on the same loop is not supported. Mixing feature 5802 and feature 5877 on the same loop is supported with a maximum of two drawers total per loop. The PCIe adapter slots use Gen3 blind-swap cassettes and support hot plugging of adapter cards. A minimum configuration of two 12X DDR cables and two ac power cables and two SPCN cables is required to ensure proper redundancy. 12X SDR cables are not supported. The drawer attaches to the host CEC enclosure with a 12X adapter in a GX slot via 12X DDR cables (#1861/#1862/#1864/#1865).
The Power 740 uses the GX++ Dual-port 12x Channel Attach (#EJ04) adapter to attach a feature 5802 12X I/O Drawer. The feature EJ04 offers double data rate (DDR) capacity bandwidth.
12X I/O Drawer PCIe, No disk (#5877)
This feature includes a 4U high 19-inch I/O drawer containing 10 PCIe 8x I/O adapter slots.
A maximum of two feature 5877 drawers can be placed on the same 12X loop. Mixing features 5877 and 5796/7314-G30 on the same loop is not supported. Mixing features 5802 and 5877 on the same loop is supported with a maximum of two drawers total per loop. The PCIe adapter slots use Gen3 blind-swap cassettes and support hot plugging of adapter cards. A minimum configuration of two 12X DDR cables and two ac power cables and two SPCN cables is required to ensure proper redundancy. 12X SDR cables are not supported. The drawer attaches to the host CEC enclosure with a 12X adapter in a GX slot via 12X DDR cables (#1861/#1862/#1864/#1865).
The Power 740 uses the GX++ Dual-port 12x Channel Attach adapter to attach a feature 5877 12X I/O Drawer. This feature delivers DDR capacity bandwidth.
Note that conversions between a diskless feature 5877 and a feature 5802 with disk bays are not available.
EXP12S SAS Drawer (#5886) (supported only -- not orderable)
The EXP12S SAS drawer (#5886) is a 2 EIA drawer that mounts in a 19-inch rack. The drawer can hold either SAS disk drives or SSDs. The EXP12S SAS drawer has twelve 3.5-inch SAS disk bays with redundant data paths to each bay. The drawer supports redundant hot-plug power and cooling and redundant hot-swap SAS expanders (Enclosure Services Manager (ESM)). Each ESM has an independent SCSI Enclosure Services (SES) diagnostic processor.
The SAS disk drives or SSDs contained in the EXP12S are controlled by one or two PCIe or PCI-X SAS adapters connected to the EXP12S via SAS cables. The SAS cable will vary, depending upon the adapter being used, the operating system being used, and the protection that you need.
- The large cache PCI-X feature 5908 uses a SAS Y cable when a single port is running the EXP12S. A SAS X cable is used when a pair of adapters is used for controller redundancy.
- The medium cache PCI-X feature 5902 and PCIe feature 5805 adapters are always paired and use a SAS X cable to attach the feature 5886 I/O drawer.
- The zero cache PCI-X feature 5912 and PCIe feature 5901 use a SAS Y cable when a single port is running the EXP12S. An SAS X cable is used for AIX and Linux environments when a pair of adapters is used for controller redundancy.
In all of the preceding configurations, all 12 SAS bays are controlled by a single controller or a single pair of controllers.
A second EXP12S drawer can be attached to another drawer using two SAS EE cables, providing 24 SAS bays instead of 12 bays for the same SAS controller port. This is called cascading. In this configuration, all 24 SAS bays are controlled by a single controller or a single pair of controllers.
The feature 5886 can also be directly attached to the SAS port on the rear of the Power 740, giving you a very low-cost disk storage solution. When used this way, the imbedded SAS controllers in the system unit drive the disk drives in EXP12S. A second unit cannot be cascaded to a feature 5886 attached in this way.
EXP24S SFF Gen2-Bay Drawer (#5887)
The EXP24S SFF Gen2-Bay Drawer is an expansion drawer with twenty- four 2.5-inch form factor (SFF) SAS bays. It supports up to 24 hot- swap SFF SAS HDDs on POWER6 or POWER7 servers in 2U of 19-inch rack space. The EXP24S bays are controlled by SAS adapters/controllers attached to the I/O drawer by SAS X or Y cables.
The SFF bays of the EXP24S are different from the SFF bays of the POWER7 system units or 12X PCIe I/O Drawer (#5802). The EXP24S uses Gen2 or SFF-2 SAS drives that physically do not fit in the Gen1 or SFF-1 bays of the POWER7 system unit or 12X PCIe I/O Drawers or vice versa.
The following SFF-2/Gen2 SAS drives can be used in the EXP24S:
- HDD
- 10,000 rpm 283 GB/300 GB (#1956, #1925, #1844, #1869)
- 10,000 rpm 571 GB/600 GB (#1962, #1964, #1817, #1818)
- 10,000 rpm 856 GB (#1738, #EQ38)
- 10,000 rpm 900 GB (#1752, #EQ52)
- 15,000 rpm 139 GB/146 GB (#1947, #1917, #1868, #1866)
- 15,000 rpm 283 GB (#1948, #1927)
- 10,000 rpm 283 GB (#1953, #1929)
- SSD
- 177 GB (#1793, #1794, #1887, and #1958)
- 387 GB (#ESRC, #ESRD, #ES0C, #ES0D, #EQ0C, and #EQ0D)
The SAS adapters/controllers that support the EXP24S are:
- PCI-X 1.5 GB Cache SAS RAID Adapter 3 Gb (#5908)
- PCIe2 1.8 GB Cache RAID SAS Adapter Tri-port 6 Gb (#5913)
- PCIe Dual-x4 SAS Adapter 3 Gb (#5901, #5278)
The integrated SAS controllers that support the EXP24S off the imbedded SAS port on the rear of the server are in the following:
- Power 710, 720, 730, 740, 750, 755, 770, and 780
- Power 520 (8203-E4A) and Power 550 (8204-E8A)
AIX, Linux, and VIOS support all of the above SAS adapters/controllers with the EXP24S. IBM i supports all but the feature 5901 and 5278 adapters with the EXP24S.
Up to 24 HDDs can be supported with any of the supported SAS adapters/controllers.
The EXP24S has an adjustable set of rails that enables it to fit in standard Power Systems 19-inch racks such as the 7014-T42 or T00 or the feature 0551 or 0553.
EXP30 Ultra SSD I/O Drawer (#EDR1)
Feature EDR1 is a 1U high I/O drawer providing 30 hot-swap SSD bays and a pair of integrated, large write cache, high-performance SAS controllers. Ultrahigh levels of performance are offered without using any PCIe slots on the POWER7 server in an ultradense packaging design.
The two high-performance, integrated SAS controllers each physically provide 3.1 GB write cache. Working as a pair, they offer mirrored write cache data and controller redundancy. The cache contents are designed to be protected by built-in flash memory in case of power failure. If the pairing is broken, write cache is not used after existing cache content is written out to the drive and performance will probably be slowed until the controller pairing is reestablished.
Each controller is connected to a GX++ PCIe adapter in a server (for example #EJ03) over a PCIe x8 Cable (such as #EN05 or #EN07). Usually both controllers are attached to one server, but each controller can be assigned to a different server or partition or VIOS. Active/Active capability is supported assuming at least two RAID arrays. The controllers deliver RAID 0, RAID 5, RAID 6, and RAID 10 for AIX and Linux and VIOS. The controllers provide RAID 5 and RAID 6 for IBM i. AIX, IBMi, Linux, and VIOS also offer OS mirroring (LVM). The adapter's CCIN is 57C3.
eMLC SSD designed to fit in the Ultra drawer bays such as the 387 GB #ES02 SSD are used. A minimum of six SSDs are required in each Ultra drawer. Each controller can access all 30 SSD bays. The bays can be configured as one set of bays run by a pair of controllers working together. Or the bays can be divided into two logical sets where each of the two controllers "owns" one of the logical sets. With proper software, if one of the controllers fails, the other controller can run both sets of bays.
19-inch racks
The Model 8205-E6D and its I/O drawers are designed to mount in the 25U 7014-S25 (#0555), 36U 7014-T00 (#0551), or the 42U 7014-T42 (#0553) rack. These racks are built to the 19-inch EIA standard. When you order a new 8205 system, you can also order the appropriate 7014 rack model with the system hardware on the same initial order. IBM is making the racks available as features of the 8205-E6D when you order additional I/O drawer hardware for an existing system (MES order). The rack feature number should be used if you want IBM to integrate the newly ordered I/O drawer in a 19-inch rack before shipping the MES order.
1.3-meter rack (#0555 - supported only)
The 1.3-meter rack (#0555) is a 25 EIA unit rack. The rack is the same rack delivered when you order the 7014-S25 rack.
1.8-meter rack (#0551)
The 1.8-meter rack (#0551) is a 36 EIA unit rack. The rack that is delivered as feature 0551 is the same rack delivered when you order the 7014-T00 rack; the included features may be different. Some features that are delivered as part of the 7014-T00 must be ordered separately with the feature 0551. Order the feature 0551 only when required to support rack integration of MES orders before shipment from IBM.
2.0-meter rack (#0553)
The 2.0-meter rack (#0553) is a 42 EIA unit tall rack. The rack that is delivered as feature 0553 is the same rack delivered when you order the 7014-T42 rack; the included features may be different. Some features that are delivered as part of the 7014-T42 must be ordered separately with the feature 0553. Order the feature 0553 only when required to support rack integration of MES orders prior to shipment from IBM.
IBM Power Systems Deployment-ready Services
IBM offers a portfolio of integration, configuration, and customization services for IBM Power Systems. These Deployment-ready Services are designed to accelerate client solution deployment and reduce related resources and cost. Offerings include:
- Integration:
- Component integration
- Rack integration
- Operating system preinstallation
- Unit personalization
- Third-party hardware/software installation
- Client-specified placement
- Asset tagging: Standard tagging; radio frequency identity (RFID)
- Special packaging Box consolidation:
- System customization: Remote access partitioning customized operating system/firmware
For more information on Deployment-ready Services, refer to
|
|
| Reliability, availability, and serviceability (RAS) features |
|
|
Reliability, fault tolerance, and data correction
The reliability of systems starts with components, devices, and subsystems that are designed to be highly reliable. The POWER7+ processor SCM uses lower-voltage technology, improving reliability with stacked latches to reduce soft error (SER) susceptibility. During the design and development process, subsystems go through rigorous verification and integration testing processes. During system manufacturing, systems go through a thorough testing process to help ensure the highest level of product quality.
The system cache and memory offer ECC (error checking and correcting) fault-tolerant features. ECC is designed to correct environmentally induced, single-bit, intermittent memory failures and single-bit hard failures. With ECC, the likelihood of memory failures will be reduced. ECC also provides double-bit memory error detection that helps protect data in the event of a double-bit memory failure.
The AIX and IBM i operating systems provide disk drive mirroring and disk drive controller duplexing. The Linux operating system supports disk drive mirroring (RAID 1) through software, while other RAID protection schemes are provided via hardware RAID adapters.
Memory error correction extensions
The memory has single-bit-error correction and double-bit-error detection ECC circuitry. The ECC code is also designed such that the failure of any one specific memory module within an ECC word by itself can be corrected absent any other fault.
Memory protection features include scrubbing to detect errors, a means to call for the deallocation of memory pages for a pattern of correctable errors detected, and signaling deallocation of a logical memory block when an error occurs that cannot be corrected by the ECC code.
Fault monitoring functions
Disk drive fault tracking is designed to alert the system administrator of an impending disk drive failure before it impacts client operation.
Mutual surveillance
The Service Processor monitors the operation of the firmware during the boot process, and also monitors the hypervisor for termination. The hypervisor monitors the Service Processor and will perform a reset/reload if it detects the loss of the Service Processor. If the reset/reload does not correct the problem with the Service Processor, the hypervisor will notify the operating system and the operating system can take appropriate action, including calling for service.
Environmental monitoring functions
POWER7+ technology-based servers include a range of environmental monitoring functions:
- Temperature monitoring warns the system administrator of potential environmental-related problems by monitoring the air inlet temperature. When the inlet temperature rises above a warning threshold, the system initiates an orderly shutdown. When the temperature exceeds the critical level or if the temperature remains above the warning level for too long, the system will shut down immediately.
- Fan speed is controlled by monitoring actual temperatures on critical components and adjusting accordingly. If internal component temperatures reach critical levels, the system will shut down immediately, regardless of fan speed. When a redundant fan fails, the system calls out the failing fan and continues running. When a nonredundant fan fails, the system shuts down immediately.
Availability enhancement functions
The POWER7+ family of systems continues to offer and introduce significant enhancements designed to increase system availability.
POWER7 processor functions
As in POWER6 and POWER7, the POWER7+ processor can perform processor instruction retry and alternate processor recovery for a number of core-related faults. This is designed to significantly reduce exposure to both hard (logic) and soft (transient) errors in the processor core. Soft failures in the processor core are transient (intermittent) errors, often due to cosmic rays or other sources of radiation, and generally are not repeatable. When an error is encountered in the core, the POWER7+ processor is designed to first automatically retry the instruction. If the source of the error was truly transient, the instruction will succeed and the system will continue as before. On IBM systems before POWER6, this error would have caused a checkstop.
Hard failures are more difficult, being true logical errors that will be replicated each time the instruction is repeated. Retrying the instruction will not help in this situation. As in POWER6 and POWER7, POWER7+ processors can extract the failing instruction from the faulty core and retry it elsewhere in the system for a number of faults, after which the failing core is dynamically deconfigured and called out for replacement. These systems are designed to avoid a full system outage.
POWER7+ single processor checkstopping
As in POWER6, POWER7+ includes single processor checkstopping for certain faults that cannot be handled by the availability enhancements described in the preceding section. This significantly reduces the probability of any one processor affecting total system availability.
Partition availability priority
Also available is the ability to assign availability priorities to partitions. If an alternate processor recovery event requires spare processor resources in order to protect a workload, when no other means of obtaining the spare resources is available, the system will determine which partition has the lowest priority and attempt to claim the needed resource. On a properly configured POWER7+ processor-based server, this allows that capacity to be first obtained from, for example, a test partition instead of a financial accounting system.
POWER7+ cache availability
The L2 and L3 caches in the POWER7+ processor are protected with double-bit detect, single-bit correct error detection code (ECC). In addition, the caches maintain a cache line delete capability. A threshold of correctable errors detected on a cache line can result in the data in the cache line being purged and the cache line removed from further operation without requiring a reboot. An ECC uncorrectable error detected in the cache can also trigger a purge and delete of the cache line. This results in no loss of operation if the cache line contained data unmodified from what was stored in system memory. Modified data would be handled through Special Uncorrectable Error handling. L1 data and instruction caches also have a retry capability for intermittent error and a cache set delete mechanism for handling solid failures. In addition, the POWER7+ processors also have the ability to dynamically substitute a faulty bit-line in an L3 cache dedicated to a processor with a spare bit-line.
Special uncorrectable error handling
Special uncorrectable error (SUE) handling prevents an uncorrectable error in memory or cache from immediately causing the system to terminate. Rather, the system tags the data and determines whether it will ever be used again. If the error is irrelevant, it will not force a check stop. If the data is used, termination may be limited to the program/kernel or hypervisor owning the data; or the I/O adapters controlled by an I/O hub controller would freeze if data were transferred to an I/O device.
PCI extended error handling
PCI extended error handling (EEH)-enabled adapters respond to a special data packet generated from the affected PCI slot hardware by calling system firmware, which examines the affected bus, allows the device driver to reset it, and continues without a system reboot. For Linux, EEH support extends to the majority of frequently used devices, although some third-party PCI devices may not provide native EEH support.
Predictive failure and dynamic component deallocation
Servers with Power processors have long had the capability to perform predictive failure analysis on certain critical components such as processors and memory. When these components exhibit certain symptoms that may indicate a failure is imminent, the system can dynamically deallocate and call home, when enabled, about the failing part before the error is propagated system-wide. In many cases, the system will first attempt to reallocate resources in such a way that will avoid unplanned outages. In the event that insufficient resources exist to maintain full system availability, these servers will attempt to maintain partition availability by user-defined priority.
Uncorrectable error recovery
When the auto-restart option is enabled, the system can automatically restart following an unrecoverable software error, hardware failure, or environmentally induced (ac power) failure.
Serviceability
The purpose of serviceability is to repair the system while attempting to minimize or eliminate service cost (within budget objectives), while maintaining high client satisfaction. Serviceability includes system installation, MES (system upgrades and downgrades), and system maintenance and repair. Depending upon the system and warranty contract, service may be performed by the client, an IBM representative, or an authorized warranty service provider.
The serviceability features delivered in this system provide a highly efficient service environment by incorporating the following attributes
- Design for client set-up (CSU), client installed features (CIF), and customer replaceable units (CRU)
- Error detection and fault isolation (ED/FI)
- First failure data capture (FFDC)
- Converged service approach across multiple IBM server platforms
Service environments
The HMC is a dedicated server that provides functions for configuring and managing servers for either partitioned or full-system partition using a GUI or command-line interface (CLI). An HMC attached to the system allows support personnel (with client authorization) to remotely log in to review error logs and perform remote maintenance if required.
The POWER7+ processor-based platforms support two main service environments:
- Attachment to one or more HMCs is a supported option by the system. This is the default configuration for servers supporting logical partitions with dedicated or virtual I/O. In this case, all servers have at least one logical partition.
- No HMC. There are two service strategies for non-HMC systems:
- Full system partition: A single partition owns all the server resources and only one operating system may be installed.
- Partitioned system: In this configuration, the system can have more than one partition and can be running more than one operating system. In this environment, partitions are managed by the Integrated Virtualization Manager (IVM), which provides some of the functions provided by the HMC.
Service Interface
The Service Interface enables support personnel to communicate with the service support applications in a server using a console, interface, or terminal. Delivering a clear, concise view of available service applications, the Service Interface enables the support team to manage system resources and service information in an efficient and effective way. Applications available via the Service Interface are carefully configured and placed to give service providers access to important service functions.
Different service interfaces are used, depending on the state of the system and its operating environment. The primary service interfaces are:
- LEDs
- Operator Panel
- Service Processor menu
- Operating system service menu
- Service Focal Point on the HMC
- Service Focal Point Lite on IVM
In the light path LED implementation, the system can clearly identify components for replacement by using specific component-level LEDs, and can also guide the servicer directly to the component by signaling (turning on solid) the amber system fault LED, enclosure fault LED, and the component FRU fault LED. The servicer can also use the identify function to blink the FRU-level LED. When this function is activated, a roll-up to the blue enclosure locate and system locate LEDs will occur. These LEDs will turn on solid and can be used to follow the light path from the system to the enclosure and down to the specific FRU.
First-failure data capture (FFDC) and error data analysis
FFDC is a technique that helps ensure that when a fault is detected in a system, the root cause of the fault will be captured without the need to re-create the problem or run any sort of extended tracing or diagnostics program. For the vast majority of faults, a good FFDC design means that the root cause can also be detected automatically without servicer intervention.
FFDC information, error data analysis, and fault isolation are necessary to implement the advanced serviceability techniques that enable efficient service of the systems and to help determine the failing items.
In the rare absence of FFDC and error data analysis, diagnostics are required to re-create the failure and determine the failing items.
Diagnostics
General diagnostic objectives are to detect and identify problems such that they can be resolved quickly. Elements of IBM's diagnostics strategy include:
- Common error code format equivalent to a system reference code, system reference number, checkpoint, or firmware error code.
- Fault detection and problem isolation procedures.
- Support for the remote connection ability to be used by the IBM Remote Support Center or IBM Designated Service.
- Interactive intelligence within the diagnostics with detailed online failure information while connected to IBM's back-end system.
Automatic diagnostics
Because of the FFDC technology designed into IBM servers, it is not necessary to perform re-create diagnostics for failures or require user intervention. Solid and intermittent errors are designed to be correctly detected and isolated at the time the failure occurs. Runtime and start time diagnostics fall into this category.
Stand-alone diagnostics
As the name implies, stand-alone or user-initiated diagnostics require user intervention. The user must perform manual steps, including:
- Running compact disk-based diagnostics
- Keying in commands
- Interactively selecting steps from a list of choices
Concurrent maintenance
The system will continue to support concurrent maintenance of power, cooling, HDD or SSD, DVD, and firmware updates (when possible). The determination of whether a firmware release can be updated concurrently is identified in the readme information file released with the firmware.
Service labels
Service providers use these labels to assist them in performing maintenance actions. Service labels are found in various formats and positions, and are intended to transmit readily available information to the servicer during the repair process. Following are some of these service labels and their purpose:
- Location diagrams: Location diagrams are strategically located on the system hardware, relating information regarding the placement of hardware components. Location diagrams may include location codes, drawings of physical locations, concurrent maintenance status, or other data pertinent to a repair. They are especially useful when multiple components are installed such as DIMMs, CPUs, processor books, fans, adapter cards, LEDs, and power supplies.
- Remove/replace procedures: Service labels that contain remove/replace procedures are often found on a cover of the system or in other spots accessible to the servicer. These labels provide systematic procedures, including diagrams, detailing how to remove or replace certain serviceable hardware components.
- Arrows: Numbered arrows are used to indicate the order of operation and serviceability direction of components. Some serviceable parts such as latches, levers, and touch points need to be pulled or pushed in a certain direction and certain order for the mechanical mechanisms to engage or disengage. Arrows generally improve the ease of serviceability.
Packaging for service The following service enhancements are included in the physical packaging of the systems to facilitate service:
- Color coding (touch points): Terracotta-colored touch points indicate that a component (FRU/CRU) can be concurrently maintained. Blue-colored touch points delineate components that are not concurrently maintained -- those that require the system to be turned off for removal or repair.
- Tool-less design: Selected IBM systems support tool-less or simple tool designs. These designs require no tools or simple tools such as flathead screw drivers to service the hardware components.
- Positive retention: Positive retention mechanisms help to assure proper connections between hardware components such as cables to connectors, and between two cards that attach to each other. Without positive retention, hardware components run the risk of becoming loose during shipping or installation, preventing a good electrical connection. Positive retention mechanisms like latches, levers, thumb-screws, pop Nylatches (U-clips), and cables are included to help prevent loose connections and aid in installing (seating) parts correctly. These positive retention items do not require tools.
Error handling and reporting
In the event of system hardware or environmentally induced failure, the system runtime error capture capability systematically analyzes the hardware error signature to determine the cause of failure. The analysis result will be stored in system NVRAM. When the system can be successfully restarted either manually or automatically, the error will be reported to the operating system. Error Log Analysis (ELA) can be used to display the failure cause and the physical location of the failing hardware.
With the integrated Service Processor, the system can automatically send out an alert via phone line to a pager or call for service in the event of a critical system failure. A hardware fault will also turn on the amber system fault LED located on the system unit to alert the user of an internal hardware problem. The indicator can also be set to blink by the operator as a tool to allow system identification. For identification, the blue locate LED on the enclosure and at the system level will turn on solid. The amber system fault LED will be on solid when an error condition occurs.
On POWER7+ processor-based servers, hardware and software failures are recorded in the system log. When an HMC is attached, an ELA routine analyzes the error, forwards the event to the Service Focal Point (SFP) application running on the HMC, and notifies the system administrator that it has isolated a likely cause of the system problem. The Service Processor event log also records unrecoverable checkstop conditions, forwards them to the SFP application, and notifies the system administrator. Once the information is logged in the SFP application, if the system is properly configured, a call home service request will be initiated and the pertinent failure data with service parts information and part locations will be sent to an IBM service organization. Client contact information and specific system- related data such as the machine type, model, and serial number, along with error log data related to the failure are sent to IBM Service.
Live partition mobility
With Live Partition Mobility, you can migrate an AIX or Linux partition running on one POWER7 or POWER7+ partition system to another POWER6, POWER7, or POWER7+ system without disrupting services. Also, IBM i and Linux partitions are enabled to migrate to another system without disrupting services. The migration transfers the entire system environment, including processor state, memory, attached virtual devices, and connected users. It provides continuous operating system and application availability during planned partition outages for repair of hardware and firmware faults, or continuous availability during a concurrent repair that requires freeing up CEC resources.
Service Processor
The Service Processor can help diagnose, check the status of, and sense the operational conditions of a system. It runs on its own power boundary and does not require resources from a system processor to be operational to perform its tasks.
The Service Processor supports surveillance of the connection to the HMC and to the system firmware (hypervisor). It also includes several remote power control options, environmental monitoring, reset, restart, remote maintenance, and diagnostic functions, including console mirroring. The Service Processors menus (ASMI) can be accessed concurrently with system operation, allowing nondisruptive abilities to change system default parameters.
Call Home
Call Home refers to an automatic or manual call from a client location to IBM support structure with error log data, server status, or other service-related information. Call Home invokes the service organization in order for the appropriate service action to begin. Call Home can be done through HMC or most non-HMC managed systems. While configuring Call Home is optional, you are encouraged to implement this feature to obtain service enhancements such as reduced problem determination and faster and potentially more accurate transmittal of error information. In general, using the Call Home feature can result in increased system availability. The Electronic Service Agent application can be configured for automated call home. Refer to the next section for specific details on this application.
IBM Electronics Services
The IBM Electronic Services web portal solution comprises Electronic Service Agent and the IBM Electronic Services solution -- dedicated to providing fast, exceptional support to IBM clients. IBM Electronic Service Agent is a no-charge tool that proactively monitors and reports hardware events such as system errors, performance issues, and inventory. Electronic Service Agent can help focus on the client's company strategic business initiatives, save time, and spend less effort managing day-to-day IT maintenance issues.
Integrated in the operating system in addition to the HMC, Electronic Service Agent is designed to automatically and electronically report system failures and client-perceived issues to IBM, which can result in faster problem resolution and increased availability. System configuration and inventory information collected by Electronic Service Agent also can be viewed on the secure Electronic Services web portal and used to improve problem determination and resolution between the client and the IBM support team. As part of an increased focus to ensure even better service to IBM clients, Electronic Service Agent tool configuration and activation comes standard with the system. In support of this effort, a new HMC External Connectivity security whitepaper has been published, which describes data exchanges between the HMC and the IBM Service Delivery Center (SDC) and the methods and protocols for this exchange. To read the white paper and prepare for Electronic Service Agent installation, go to the "Reference Guide" section at
- Select your country.
- Click on "IBM Electronic Service Agent Connectivity Guide."
Benefits
Increased uptime:
Electronic Service Agent is designed to enhance the warranty and maintenance service by providing faster hardware error reporting and uploading system information to IBM Support. This can optimize the time monitoring the symptoms, diagnosing the error, and manually calling IBM Support to open a problem record. And 24x7 monitoring and reporting means no more dependency on human intervention or off-hours client personnel when errors are encountered in the middle of the night.
Security:
Electronic Service Agent is secure in monitoring, reporting, and storing the data at IBM. It securely transmits via the Internet (HTTPS or VPN) and can be configured to communicate securely through gateways to give clients a single point of exit from their site. Communication between the client and IBM only flows one way; activating Service Agent does not enable IBM to call into a client's system. System inventory information is stored in a secure database, which is protected behind IBM firewalls. The client's business applications or business data is never transmitted to IBM.
More accurate reporting:
Because system information and error logs are automatically uploaded to the IBM Support Center in conjunction with the service request, clients are not required to find and send system information, decreasing the risk of misreported or misdiagnosed errors. Once inside IBM, problem error data is run through a data knowledge management system and knowledge articles are appended to the problem record.
Customized support:
Using the IBM ID entered during activation, clients can view system and support information in the "My Systems" and "Premium Search" sections of the Electronic Services website.
The Electronic Services web portal is a single Internet entry point that replaces the multiple entry points traditionally used to access IBM Internet services and support. This web portal enables you to gain easier access to IBM resources for assistance in resolving technical problems. The newly improved My Systems and Premium Search functions make it even easier for Electronic Service Agent-enabled clients to track system inventory and find pertinent fixes.
My Systems offers valuable reports of installed hardware and software using information collected from the systems by IBM Electronic Service Agent. Reports are available for any system associated with the client's IBM ID. Premium Search combines the function of search and the value of Electronic Service Agent information, providing advanced search of the technical support knowledgebase. Using Premium Search and the Service Agent information that has been collected from the system, you can see search results that apply specifically to your systems.
For more information on how to use the power of IBM Electronic Services, visit the following website or contact an IBM Systems Services Representative
Accessibility by people with disabilities
A US Section 508 Voluntary Product Accessibility Template (VPAT) containing details on accessibility compliance can be requested at
|
|
| Models |
|
|
Model summary matrix
| Model | Processor | Speed | Memory | Internal HDD/SSD | Internal Slots | Internal Bays |
|---|---|---|---|---|---|---|
| E6D | POWER7+ | - | 8 GB/1024 GB | 7.2 TB | 6 | 8 2.5" SFF/2 Media |
| - | 4-core | 4.3 GHz | - | - | - | - |
| - | 6-core | 4.2 GHz | - | - | - | - |
| - | 8-core | 3.6 GHz | - | - | - | - |
| - | 8-core | 4.2 GHz | - | - | - | - |
Customer setup (CSU)
Yes, except for feature numbers EPCP, EPCQ, EPCR, 1995, 1996, and 9743.
Devices supported
The following external machine types are supported on the indicated models for MT 8205.
This list is not all inclusive. Many devices are supported through standard ports. Refer to the sales manual of the external machine type and the list of supported devices in the appropriate section of the sales manual for further attach support information.
E X = SUPPORTED DEVICE
6
D
MT-MOD DESCRIPTION
--------- - ---------------------------------------------------------
---------+-+--------Communications-----------------------------------
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
7036-P16 X IBM 7036-P16
---------+-+--------Disk---------------------------------------------
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
1710-10U X IBM System Storage EXP100 Expansion Unit
1722-60U X IBM System Storage DS4300 Disk System
1722-6LU X IBM System Storage DS4300 Disk System
1724-100 X IBM System Storage DS4100 Disk System
1740-710 X IBM System Storage EXP710 Expansion Unit
1742-1RU X IBM 1742-1RU
1742-90U X IBM System Storage DS4500 Disk System
1750-511 X IBM 1750-511
1750-522 X IBM 1750-522
1750-EX1 X IBM 1750-EX1
1812-81A X IBM System Storage DS4000 EXP810 Storage Expansion Unit
Model 81
1812-81S X IBM System Storage DS4000 EXP810 Expansion Unit Model
81-DC
1812-8VA X IBM System Storage DS4000 EXP420 Storage Expansion Unit
1814-20A X IBM 1814 DS5020 Disk Controller Model 20A
1814-52A X IBM 1814 EXP520 Expansion Unit
1814-70A X IBM System Storage DS4700 Express Model 70
1814-70S X IBM System Storage DS4700 Express Model 70-DC
1814-72A X IBM System Storage DS4700 Express Model 72
1814-72S X IBM System Storage DS4700 Express Model 72-DC
1814-7VA X IBM System Storage DS4200 Express Model 7V
1814-7VH X DS4200 Express Model 7V
1814-92A X IBM System Storage (EXP395) Expansion Unit
1814-94A X IBM System Storage (DS3950) Model 94
1814-98A X IBM System Storage (DS3950) Model 98
1815-80A X IBM System Storage DS4800 Model 80A
1815-82A X IBM System Storage DS4800 Model 82A
1815-84A X IBM System Storage DS4800 Model 84A
1815-88A X IBM System Storage DS4800 Model 88A
1818-51A X IBM System Storage DS5100 Disk System
1818-53A X IBM System Storage DS5300 Disk System
1818-80C X DCS3700 Storage System
1818-80E X DCS3700 Expansion Unit
1818-D1A X IBM System Storage EXP5000 Expansion Unit
2105-750 X IBM 2105-750
2105-800 X IBM 2105 ESS Model 800
2105-E20 X IBM 2105-E20
2105-F10 X IBM 2105-F10
2105-F20 X IBM 2105-F20
2107-921 X IBM 2107-921
2107-922 X IBM 2107-922
2107-931 X IBM 2107-931
2107-932 X IBM 2107-932
2107-9A2 X IBM 2107-9A2
2107-9AE X IBM 2107-9AE
2107-9B2 X IBM 2107-9B2
7031-D24 X IBM TotalStorage EXP24 7031-D24
7031-T24 X IBM TotalStorage EXP24 7031-T24
7204-646 X IBM 7204-646
---------+-+--------Displays-----------------------------------------
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
7042-C06 X IBM 7042-C06
7042-C07 X IBM 7042-C07
7042-CR4 X IBM 7042-CR4
7042-CR5 X IBM 7042-CR5
7042-CR6 X Rack-mount Hardware Management Console
7310-C05 X IBM 7310-C05
7310-C06 X IBM 7310-C06
7310-CR3 X IBM 7310-CR3
7310-CR4 X IBM 7310-CR4
7316-TF1 X IBM 7316-TF1
7316-TF3 X IBM 7316-TF3
9419-HB7 X IBM ThinkVision L191p 19-inch LCD Flat-panel Monitor
9513-AW1 X IBM T55A 15.0-inch Color TFT LCD Monitor
9516-B03 X IBM MultiMode 16.1-inch TFT LCD Flat Panel Monitor Model
B03
9516-B04 X IBM MultiMode 16.1-inch TFT LCD Flat Panel Monitor Model
B04
---------+-+--------Expansion Cabinets-------------------------------
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
7014-B42 X IBM 7014-B42
7014-S25 X IBM 7014-S25
7014-T00 X IBM 7014-T00
7014-T42 X IBM 7014-T42
7314-G30 X IBM 7314-G30
---------+-+--------Power--------------------------------------------
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
9910-E15 X PW9130 120vac Tower
9910-E16 X PW9130 HV ac Tower
9910-E30 X Powerware 9125 3KVA Tower/Rack
9910-E33 X POWERWARE 5125 3KVA RACK-MOUNT
9910-E35 X Powerware 9910G3000R-XL3U
9910-E36 X Powerware 9910I3000R-XL3U
9910-E50 X PW 9135 5.0kVA rack or tower
9910-E64 X Powerware 9125 6KVA Tower/Rack
9910-E65 X Powerware 5125 5KVA Rack Mount
9910-E66 X Powerware PW-9910G6kVA 208VXL4U
9910-E67 X PW 9910 6kva EXT 230V Rack
9910-E82 X Powerware 9140 10KVA Rack-Nema
9910-E83 X Powerware 9140 10KVA Rack-IEC
9910-P13 X PW5115 1.4kVA 110-127V LV NA
9910-P14 X PW5115 1.4kVA 220-240V HV WT
---------+-+--------SCSI Devices-------------------------------------
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
3996-032 X 3996-032
3996-080 X 3996-080
3996-174 X 3996-174
7210-020 X IBM 7210-020
7210-025 X IBM 7210-025
7210-030 X IBM 7210-030
---------+-+--------Storage Network Devices--------------------------
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
1750-EX2 X IBM System Storage DS6000 Expansion Unit
2076-112 X IBM Storwize V7000 Controller LFF 12-drive enclosure
2076-124 X IBM Storwize V7000 Controller SFF 24-drive enclosure
(SSDs)
2076-212 X IBM Storwize V7000 Expansion LFF 12-drive enclosure
2076-224 X IBM Storwize V7000 Expansion SFF 24-drive enclosure (SSDs)
2076-312 X IBM Storwize V7000 10 GbE Controller LFF 12-drive
enclosure
2076-324 X IBM Storwize V7000 10 GbE Controller SFF 24-drive
enclosure (SSDs)
2145-4F2 X IBM TotalStorage SAN Volume Controller Storage Engine
Model 4F2
2145-8F2 X IBM TotalStorage SAN Volume Controller Storage Engine
Model 8F2
2145-8F4 X IBM System Storage SAN Volume Controller Storage Engine
Model 8F4
2145-CF8 X IBM System Storage SAN Volume Controller Storage Engine
Model CF8
2421-921 X System storage DS8100
2421-922 X System storage DS8300
2421-92E X System Storage DS8000
2421-931 X SYSTEM STORAGE DS8100
2421-932 X SYSTEM STORAGE DS8300
2421-941 X IBM System Storage DS8700 Disk System (M/T 2421)
2421-94E X IBM System Storage DS8700 Disk System (M/T 2421)
2421-9A2 X System storage DS8300
2421-9AE X System Storage DS8000
2421-9B2 X SYSTEM STORAGE DS8300
2422-931 X SYSTEM STORAGE DS8100
2422-932 X SYSTEM STORAGE DS8300
2422-941 X IBM System Storage DS8700 Disk System (M/T 2422)
2422-94E X IBM System Storage DS8700 Disk System (M/T 2422)
2422-9AE X System Storage DS8100
2422-9B2 X SYSTEM STORAGE DS8300
2423-931 X SYSTEM STORAGE DS8100
2423-932 X SYSTEM STORAGE DS8300
2423-941 X IBM System Storage DS8700 Disk System (M/T 2423)
2423-94E X IBM System Storage DS8700 Disk System (M/T 2423)
2423-9AE X System Storage DS8000
2423-9B2 X SYSTEM STORAGE DS8300
2424-931 X SYSTEM STORAGE DS8100
2424-932 X SYSTEM STORAGE DS8300
2424-941 X IBM System Storage DS8700 Disk System (M/T 2424)
2424-94E X IBM System Storage DS8700 Disk System (M/T 2424)
2424-9AE X System Storage DS 8000
2424-9B2 X SYSTEM STORAGE DS8300
2858-A10 X IBM 2858 N6040 Storage Controller Model A10
2858-A11 X IBM 2858 N6070 Storage Controller Model A11
2858-A12 X IBM 2858 N6060 Storage Controller Model A12
2858-A20 X IBM 2858 N6040 Storage Controller Model A20
2858-A21 X IBM 2858 N6070 Storage Controller Model A21
2858-A22 X IBM 2858 N6060 Storage Controller Model A22
2859-A10 X IBM 2859 System Storage N3300 Storage Controller Model A10
2859-A20 X IBM 2859 System Storage N3300 Storage Controller Model A20
2861-001 X IBM 2861 System Storage EXN1000 Model 001
2862-A10 X IBM 2862 System Storage N3600 Model A10
2862-A20 X IBM 2862 System Storage N3600 Model A20
2863-001 X IBM System Storage EXN2000
2863-A10 X IBM System Storage N3700 Model A10
2863-A20 X IBM System Storage N3700 Model A20
2864-A10 X IBM System Storage N5200 Model A10
2864-A20 X IBM System Storage N5200 Model A20
2865-A10 X IBM System Storage N5500 Model A10
2865-A20 X IBM System Storage N5500 Model A20
2866-A10 X IBM System Storage N7600 Models A10
2866-A11 X IBM System Storage N7700 Models A11
2866-A20 X IBM System Storage N7600 Model A20
2866-A21 X IBM System Storage N7700 Model A21
2866-G11 X IBM System Storage N7700 Model G11
2866-G21 X IBM System Storage N7700 Model G21
2867-A10 X IBM System Storage N7800 Model A10
2867-A11 X IBM System Storage N7900 Model A11
2867-A20 X IBM System Storage N7800 Model A20
2867-A21 X IBM System Storage N7900 Model A21
2867-G11 X IBM System Storage N7900 Model G11
2867-G21 X IBM System Storage N7900 Model G21
4939-A29 X IBM Flex System V7000 Expansion
4939-A49 X IBM Flex System V7000 Control
---------+-+--------Switch-------------------------------------------
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
1455-24E X IBM RACKSWITCH G8124ER
1455-24L X IBM RACKSWITCH G7028
1455-48E X IBM RACKSWITCH G8052R
1455-64C X IBM RACKSWITCH G8264R
1611-16E X IBM BNT RACKSWITCH G8316
2005-B16 X IBM TotalStorage SAN16B-2
2005-B32 X IBM TotalStorage SAN32B-2 Express Model
2005-B5K X IBM System Storage SAN32B-3
2005-B64 X IBM System Storage SAN64B-2 Fabric Switch
2005-H08 X IBM TotalStorage SAN Switch H16
2005-H16 X IBM TotalStorage SAN Switch H16
2005-R18 X IBM 2005 System Storage SAN18B-R Router
2026-224 X IBM TotalStorage SAN24M-1
2026-416 X IBM TotalStorage SAN16M-2
2026-432 X IBM TotalStorage SAN32M-2
2026-E12 X IBM TotalStorage SAN12M-1
2027-140 X IBM TotalStorage SAN140M
2027-232 X IBM TotalStorage SAN32M-1
2027-256 X IBM TotalStorage SAN256M
2031-216 X IBM 2031-216
2031-232 X IBM 2031-232
2032-064 X IBM 2032-064
2032-140 X IBM 2032-140
2034-212 X IBM 2034-212
2042-001 X IBM 2042-001
2042-128 X IBM 2042-128
2042-256 X IBM 2042-256
2045-N16 X IBM 2045-N16
2053-424 X Cisco MDS 9124 for IBM System Storage Switch
2053-434 X Cisco MDS 9134 for IBM System Storage Switch
2053-S34 X Cisco MDS 9134 for IBM System Storage Switch
2054-D1A X Cisco MDS 9216A Fabric Switch
2054-E01 X Cisco MDS 9222i for IBM System Storage
2054-E04 X Cisco MDS 9506 for IBM System Storage Director
2054-E07 X Cisco MDS 9509 for IBM System Storage Director
2054-E11 X Cicso MDS 9513 for IBM System Storage Director
2061-020 X IBM 2061-020
2061-040 X IBM 2061-040
2061-420 X Cisco MDS 9020 Fabric Swtich
2062-D01 X IBM 2062-D01
2062-D04 X Cisco MDS 9506 Multilayer Director
2062-D07 X Cisco MDS 9509 Multilayer Director
2062-D1A X Cisco MDS 9216A Multilayer Fabric Switch
2062-D1H X Cisco MDS 9216i Multilayer Fabric Switch
2062-E11 X Cisco MDS 9513 Multilayer Director
2062-T04 X Cisco MDS 9506 Multilayer Director
2062-T07 X Cisco MDS 9509 Multilayer Director
2109-A16 X IBM TotalStorage SAN16B-R
2109-F16 X IBM 2109-F16
2109-F32 X IBM 2109-F32
2109-M12 X IBM 2109-M12
2109-M14 X IBM 2109-M14
2109-M48 X IBM 2109 SAN256B Director Model M48
2498-B24 X IBM System Storage SAN24B-4 Express
2498-B40 X IBM System Storage SAN40B-4
2498-B80 X IBM 2498 SAN80B-4 Model B80
2498-F48 X IBM System Storage SAN48B-5
2498-R06 X IBM 2498 System Storage SAN06N-R Model R06
2499-384 X IBM System Storage SAN768B
2499-416 X IBM System Storage SAN384B-2
2499-816 X IBM System Storage SAN768B-2
---------+-+--------Tape---------------------------------------------
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
3494-D22 X IBM TotalStorage Enterprise Tape Drive Expansion Frame
Model D22
3494-D24 X IBM TotalStorage Enterprise Tape Drive Expansion Frame
Model D24
3494-HA1 X IBM TotalStorage Enterprise High Availability Frame Model
HA1
3494-L22 X IBM TotalStorage Enterprise Tape Library Base Frame Model
L22
3572-S3H X TS2900 Tape Autoloader w/LTO3 HH SAS drive
3572-S4H X TS2900 Tape Autoloader w/LTO4 HH SAS drive
3572-S5H X TS2900 Tape Autoloader w/LTO5 HH SAS drive
3573-L2U X TS3100 Tape Library Model L2U
3573-L4U X TS3200 Tape Library Model L4U
3576-E9U X IBM System Storage TS3310 Tape Library Model E9U
3576-L5B X IBM System Storage TS3310 Tape Library Model L5B
3577-L5U X IBM 3577 TS3400 Tape Library Model L5U
3580-H23 X IBM 3580-H23
3580-H3L X System Storage TS2230 Tape Drive Express Model H3L
3580-H3S X System Storage TS2230 Tape Drive Express Model H3S
3580-H4S X System Storage TS2240 Tape Drive Express Model H4S
3580-L23 X IBM 3580-L23
3580-L33 X TotalStorage 3580 Tape Drive Model L33
3580-L43 X System Storage TS2340 Tape Drive Express Model L43
3580-S43 X System Storage TS2340 Tape Drive Express Model S43
3581-F28 X IBM 3581-F28
3581-F38 X IBM 3581-F38
3581-H23 X IBM 3581-H23
3581-L23 X IBM 3581-L23
3581-L28 X IBM 3581-L28
3581-L38 X IBM 3581-L38
3582-L23 X IBM 3582-L23
3583-L18 X IBM 3583-L18
3583-L36 X IBM 3583-L36
3583-L72 X IBM 3583-L72
3584-D22 X IBM TotalStorage UltraScalable Tape Library Model D22
3584-D23 X IBM System Storage TS3500 Tape Library Model D23
3584-D32 X IBM 3584 UltraScalable Tape Library Model D32
3584-D42 X IBM 3584 UltraScalable Tape Library Model D42
3584-D52 X IBM TotalStorage UltraScalable Tape Library Model D52
3584-D53 X IBM System Storage TS3500 Tape Library Model D53
3584-HA1 X IBM TotalStorage 3584 High Availability Frame Model HA1
3584-L22 X IBM TotalStorage UltraScalable Tape Library Model L22
3584-L23 X IBM System Storage TS3500 Tape Library Model L23
3584-L32 X IBM 3584 UltraScalable Tape Library Model L32
3584-L52 X IBM TotalStorage UltraScalable Tape Library Model L52
3584-L53 X IBM System Storage TS3500 Tape Library Model L53
3584-S24 X IBM System Storage TS3500 Tape Library Model S24
3584-S54 X IBM System Storage TS3500 Tape Library Model S54
3588-F3A X IBM TotalStorage 3588 Ultrium Tape Drive Model F3A
3588-F3B X IBM System Storage TS1030 Tape Drive Model F3B
3588-F4A X IBM System Storage TS1040 Tape Drive Model F4A
3590-H11 X IBM TotalStorage 3590 Tape Drive Model H11
3590-H1A X IBM TotalStorage 3590 Tape Drive Model H1A
3592-E05 X IBM 3592 System Storage TS1120 Tape Drive Model E05
3592-E06 X IBM 3592 System Storage TS1130 Tape Drive Model E06
3592-E07 X IBM 3592 System Storage TS1140 Tape Drive Model E07
3592-EU6 X IBM 3592 System Storage TS1130 Tape Drive Model EU6
3592-J1A X IBM TotalStorage Enterprise Tape Drive 3592
3952-F05 X IBM 3952 Tape Frame Model F05
3954-CV5 X IBM Virtualization Engine TS7510
3954-CV6 X IBM Virtualization Server TS7520 Server
3954-CV7 X IBM Virtualization Engine TS7530 Server
3955-SV5 X IBM Virtualization Engine TS7510 Model SV5
3955-SV6 X IBM Virtualization Engine TS7520 Cache Controller
3955-SX5 X IBM Virtualization Engine TS7510 Model SX5
3955-SX6 X IBM Virtualization Engine TS7520 Cache Drawer
3958-AP1 X IBM System Storage TS7650 ProtecTIER De-duplication
Appliance (3958-AP1)
3958-DD3 X IBM 3958 Model DD3 TS7650G ProtecTIER De-duplication
Gateway
7205-550 X IBM 7205-550
7206-220 X IBM 7206-220
7206-336 X IBM 7206-336
7206-VX2 X IBM 7206-VX2
7206-VX3 X IBM 7206-VX3
7212-312 X IBM 7212-312
7214-1U2 X IBM System Storage 7214 Tape and DVD Enclosure Express
7214-TT2 X IBM System Storage 7214 Tape and DVD Table-top Enclosure
(Model TT2)
7226-1U3 X IBM 7226-1U3
7332-220 X IBM 4MM DDS-4 Tape Cartridge Autoloader Model 220
Model conversions
Not available.
Feature Conversions
The existing components being replaced during a model or feature conversion become the property of IBM and must be returned.
Feature conversions are always implemented on a "quantity of one for quantity of one" basis. Multiple existing features may not be converted to a single new feature. Single existing features may not be converted to multiple new features.
The following conversions are available to customers:
Feature conversions for 8205-E6D adapters features
RETURN
From FC: To FC: PARTS
---------------------------- ---------------------------- ------
2055 - PCIe RAID & SSD SAS 2054 - PCIe RAID & SSD SAS No
Adapter 3Gb w/ Blind Swap Adapter 3Gb
Cassette
2054 - PCIe RAID & SSD SAS 2055 - PCIe RAID & SSD SAS No
Adapter 3Gb Adapter 3Gb w/ Blind Swap
Cassette
4807 - PCIe Crypto 4808 - PCIe Crypto No
Coprocessor No BSC 4765-001 Coprocessor Gen3 BSC
4765-001
Feature conversions for 8205-E6D virtualization engine features
RETURN
From FC: To FC: PARTS
---------------------------- ---------------------------- ------
5225 - PowerVM Express 5227 - PowerVM Standard No
Edition Edition
5225 - PowerVM Express 5228 - PowerVM Enterprise No
Edition Edition
5227 - PowerVM Standard 5228 - PowerVM Enterprise No
Edition Edition
Feature conversions for 8205-E6D solid state drive features
RETURN
From FC: To FC: PARTS
---------------------------- ---------------------------- ------
ES0A - 387GB SFF-1 SSD for EH14 - GEN2-S Conversion No
AIX/Linux with eMLC Carrier for Feature ES0C
387GB SSD
ES0B - 387GB SFF-1 SSD for EH16 - GEN2-S Conversion No
IBM i with eMLC Carrier for Feature ES0D
387GB SSD (IBM i)
|
|
| Technical description |
|
|
|
|
|
|
|
|
|
Physical specifications
Rack-Mount: Width: 440 mm (17.3 in) Depth: 610 mm (24.0 in) Height: 173 mm (6.81 in) Weight: 48.7 kg (107.4 lb)
To assure installability and serviceability in non-IBM industry- standard racks, review the installation planning information for any product-specific installation requirements.
Operating environment
Operating environment system exception with the 1.5 TB/3.0 TB LTO-5 SAS Tape Drive (#5638):
- Temperature (operating) 10 to 25 degrees C (50 to 95 F); allowable operating temperature 10 to 40 degrees C (50 to 104 F)
- Relative humidity: Nonoperating 10% to 80% noncondensing
- Maximum altitude: 3,048 m (10,000 ft)
System environment limits without the 1.5 TB/3.0 TB LTO-5 SAS Tape Drive (#5638)
- Temperature: (nonoperating) 5 to 45 degrees C (41 to 113 F); recommended temperature (operating) 18 to 27 degrees C (64 to 80 F); allowable operating temperature 5 to 35 degrees C (41 to 95 F)
- Relative humidity: Nonoperating 8% to 80%; recommended 5.5 degrees C (42 F) dew point to 60% RH and 15 degrees C (59 F) dew point
- Maximum dew point: 28 degrees C (84 F)(operating)
- Operating voltage: 200 to 208 or 220 to 240 V ac
- Operating frequency: 47/63 Hz
- Maximum measured power consumption: 1,630 watts (maximum)
- Power factor: 0.98
- Thermal output: 5,562 Btu/hour (maximum)
- Power-source loading
- 1.664 kVa (maximum configuration)
- Maximum altitude: 3,050 m (10,000 ft)
Note: The maximum measured value is the worst case power consumption expected from a fully populated server under an intensive workload. The maximum measured value also accounts for component tolerance and non-ideal operating conditions. Power consumption and heat load vary greatly by server configuration and utilization. The IBM Systems Energy Estimator should be used to obtain a heat output estimate based on a specific configuration
Noise level and sound power
- Rack-mount system: 6.0 Bels operating; 5.9 Bels idling
EMC conformance classification:
This equipment is subject to FCC rules and shall comply with the appropriate FCC rules before final delivery to the buyer or centers of distribution.
- US: FCC Class A
- Europe: CISPR 22 Class A
- Japan: VCCI-A
- Korea: Korean Requirement Class A
- China: People's Republic of China commodity inspection law Class A
Homologation -- Telecom environmental testing (Safety and EMC):
Homologation approval for specific countries has been initiated with the IBM Homologation and Type Approval (HT&A) organization in LaGaude, France. This Power Systems model and applicable features meet the environmental testing requirements of the country telecom and have been designed and tested in compliance with the Full Quality Assurance Assurance Approval (FQAA) process as delivered by the British Approval Board for Telecom (BABT), the UK Telecom regulatory authority.
This product is not certified for connection by any means whatsoever to interfaces of public telecommunications networks. Certification may be required by law prior to making any such connection. Contact an IBM representative or reseller for any questions.
Product safety/Country testing/Certification
- UL 60950 Underwriters Laboratory, Safety Information
- CSA C22.2 No. 60950-00, Canadian Standards Association
- EN60950 European Norm
- IEC 60950, Edition 1, International Electrotechnical Commission, Safety Information
- Nordic deviations to IEC 60950-1 1st Edition
General requirements:
The product is in compliance with IBM Corporate Bulletin C-B 0-2594-000 Statement of Conformity of IBM Product to External Standard (Suppliers Declaration).
Homologation
This product is not certified for direct connection by any means whatsoever to interfaces of public telecommunications networks. Certification may be required by law prior to making any such connection. Contact an IBM representative or reseller for any questions.
Limitations
System
- Integrated system ports are not supported under AIX or Linux when the HMC ports are connected to an HMC. Either the HMC ports or the integrated system ports can be used, but not both. IBM i can continue to use a system port for communication to a UPS, even with an HMC attached.
- The integrated system ports are supported for modem and asynch terminal connections by AIX or Linux. Any other application using serial ports requires a serial port adapter to be installed in a PCI slot. The integrated system ports do not support HACMP configurations. IBM i only supports the use of the system ports for attachment to a UPS.
Hardware Management Console (HMC) machine code
An HMC or IVM is required to manage the Power 740 (8205-E6D) implementing partitioning. Multiple POWER7 processor-based servers can be supported by a single HMC.
If an HMC is used to manage the Power 740, the HMC must be a rack- mount model CR3, or later, or deskside model C05, or later.
If attaching an HMC to a new server or adding function to an existing server that requires a firmware update, the HMC machine code may need to be updated. Machine code includes firmware and microcode. Access to machine code updates is conditioned on entitlement and license validation in accordance with IBM policy and practice. IBM may verify entitlement through customer number, serial number, electronic restrictions, or any other means or methods employed by IBM in its discretion.
To determine the HMC machine code level required for the firmware level on any server, go to the following web page to access the Fix Level Recommendation Tool (FLRT) on or after the planned availability date for this product. FLRT will identify the correct HMC machine code for the selected system firmware level
https://www14.software.ibm.com/webapp/set2/sas/f/hmc/home.html
If a single HMC is attached to multiple servers, the HMC machine code level must be updated to the server with the most recent firmware level. All prior levels of server firmware are supported with the latest HMC machine code level.
When IBM Systems Director is used to manage an HMC or if the HMC manages more than 254 partitions, the HMC should have 3 GB of RAM minimum and be a rack-mount model CR3, or later, or deskside model C06, or later.
The HMC Release 7.7.0 Service Pack 1 contains support for managing IBM Power 710, 720, 730, 740, and IBM PowerLinux 7R1/7R2 systems.
The HMC V7.7.0 (SP1) contains the following:
- Support for managing IBM Power 750 and 760
- Support for PowerVM functions such as new HMC GUI interface for VIOS install
- Improved transition from IVM to HMC management
- Support for 802.1 Qbg on virtual Ethernet adapters
- Ability to update the user's password in Kerberos from the HMC for clients utilizing remote HMC
Boot requirements
- Selection of feature 0837 will indicate boot from SAN.
- If IBM i (#2145) is selected as the primary operating system and
SAN boot is not selected (#0837), one of the following Load/Source
specify codes must be specified:
- #0722 -- #1787 (177 GB SFF SSD) Load Source Specify
- #0724 -- #1996 (177 GB 1.8" SSD) Load Source Specify
- #0726 -- Remote Load Source Specify in #5802/#5803
- #0727 -- Remote Load Source Specify in #5886
- #0728 -- Remote Load Source Specify in #5887
- #0729 -- Remote Load Source Specify in #5888
- #0838 -- #3676 (69.7 GB 15K RPM HDD) Load Source Specify
- #0839 -- #3677 (139.5 GB 15K RPM HDD) Load Source Specify
- #0840 -- #3678 (283.7 GB 15K RPM HDD) Load Source Specify
- #0844 -- #3658 (428 GB 15K RPM HDD) Load Source Specify
- #0851 -- #1884 (69.7 GB 15K RPM SFF HDD) Load Source Specify
- #0853 -- #1888 (139.5 GB 15K RPM SFF HDD) Load Source Specify
- #0855 -- #3586 (69 GB SSD) Load Source Specify
- #0856 -- #1911 (283 GB 10K RPM SFF HDD) Load Source Specify
- #0857 -- #1916 (571 GB 10K RPM SFF HDD) Load Source Specify
- #0870 -- #1879 (283 GB 15K RPM SFF HDD) Load Source Specify
- #0871 -- #1947 (139 GB 15K RPM SFF HDD) Load Source Specify
- #0872 -- #1948 (283 GB 15K RPM SFF HDD) Load Source Specify
- #0874 -- #1956 (283 GB 10K RPM SFF HDD) Load Source Specify
- #0875 -- #1962 (571 GB 10K RPM SFF HDD) Load Source Specify
- #0876 -- #1794 (177 GB SFF SSD) Load Source Specify
- #0879 -- #1737 (856 GB 10K RPM SFF HDD) Load Source Specify
- #0880 -- #1738 (856 GB 10K RPM SFF HDD) Load Source Specify
- #0893 -- #ES0B (387 GB SFF SSD) Load Source Specify
- #0894 -- #ES0D (387 GB SFF SSD) Load Source Specify
- If IBM i (#2145) is selected and the load source disk unit is not
in the CEC (system unit), one of the following specify codes must also
be selected:
- #0726 -- Remote Load Source in #5802 12X I/O Drawer PCIe, SFF Disk
- #0727 -- Remote Load Source in #5886 EXP12S Expansion Drawer
- #0728 -- Remote Load Source in #5887 EXP24S Expansion Drawer
- #0729 -- Remote Load Source in #EDR1 EXP30 Ultra SSD I/O Drawer
- #0837 -- SAN Load Source Specify (Boot from SAN)
- If IBM i (#2145) is selected, one of the following system console
specify codes must be selected:
- #5550 -- System Console on HMC
- #5557 -- System Console - Internal LAN
Processor modules
- A minimum of one processor module is required on an order with six or eight processor cores on the processor module. A maximum of two processor modules is allowed on an order. A quantity of one or two of processor modules EPCP, EPCQ, or EPCR can be ordered.
- All processor cores must be activated.
- The 6-core 4.2 GHz processor module (#EPCP) requires that six processor activation codes be ordered. A maximum of six processor activation code features (6 x #EPDP, or 3 x #EPDP and 3 x #EPEP) are allowed per processor module.
- The 8-core 3.6 GHz processor module (#EPCQ) requires that eight processor activation codes be ordered. A maximum of eight processor activation code features (8 x #EPDQ, or 4 x #EPDQ and 4 x #EPEQ) are allowed per processor module.
- The 8-core 4.2 GHz processor module (#EPCR) requires that eight processor activation codes be ordered. A maximum of eight processor activation code features (8 x #EPDR, or 4 x #EPDR and 4 x #EPER) are allowed per processor module.
Power supply
The base machine contains two 1925 watt ac power supplies (2 x #5532).
Redundant fans
Redundant fans are standard.
Power cords
Two power cords are required. A maximum of 2 x feature 6665 is allowed on the system unless a valid I/O drawer or tower is attached to the system. The Power 740 supports 200 - 240 V ac.
System memory
- A minimum 8 GB of memory is required on the Power 740 system.
- The base machine contains one nonfeaturized memory riser card with eight DIMM sockets. Memory features consume two memory DIMM sockets.
- One additional optional memory riser card feature (1 x #EM01) with an additional eight DIMM sockets is available when one processor module is installed in the system (1 x EPCP/EPCQ/EPCR). Three optional memory riser card features (3 x #EM01) with an additional eight DIMM sockets per feature are available when two processor modules are installed in the system (2 x EPCP/EPCQ/EPCR). Maximum system memory is 256 GB without feature EM01 and 1024 GB with 3 x feature EM01.
- A system can be ordered with a single memory feature; 1 x EM04 is not permitted.
- It is generally recommended that memory be installed evenly across all memory riser cards in the system. Balancing memory across the installed memory riser cards allows memory access in a consistent manner and typically results in the best possible performance for your configuration. However, balancing memory fairly evenly across multiple memory riser cards, compared to balancing memory exactly evenly, typically has a very small performance difference.
Plans for future memory upgrades should be taken into account when deciding which memory feature size to use at the time of initial system order.
Figure 1. Memory features
Feature Minimum Maximum
Feature number quantity quantity
8 GB 1066 MHz EM08 0 16
(2 x 4 GB RDIMMs)
16 GB 1066 MHz EM4B 0 16
(2 x 8 GB RDIMMs)
32 GB 1066 MHz EM4C 0 16
(2 x 16 GB RDIMMs)
64 GB 1066 MHz EM4D 0 16
(2 x 32 GB RDIMMs)
Drawer/Tower attachment:
- 7314-G30 (#5796) PCIX Expansion Drawer (supported, not orderable)
- Maximum of four drawers per GX++ adapter (#EJ04 or follow-ons) or per 12X loop
- Maximum of two GX++ adapters on the Power 740
- System maximum of four with one processor module and eight with two processor modules
- Feature number 5886 EXP12S SAS HDD or SSD Expansion Drawer
(supported, not orderable)
- Feature number EJ01 supports one feature number 5886 drawer directly off the system unit's SAS port.
- EXP12S drawers are attached to a PCI-X or PCIe SAS adapter via SAS cables.
- The system maximum is 28.
- Feature number 5887 EXP24S SAS HDD or SSD Expansion Drawer
- Feature number EJ01 supports one feature number 5887 drawer directly off the system unit's SAS port.
- EXP24S drawers are attached to a PCI-X or PCIe SAS adapter via SAS cables.
- The system maximum is 14.
- Feature number 5802 12X I/O Drawer PCIe SFF Disk and feature
number 5877 12X I/O Drawer PCIe No Disks
- A maximum of two per 12X loop is allowed.
- A maximum of two is supported with one processor module and a maximum of four is supported with two processor modules on the Power 740.
- No mixing of features 5802 and 5877 is allowed with other drawers on the same loop.
- Feature number EDR1 EXP30 Ultra SSD I/O Drawer
- EXP30 Ultra SSD I/O Drawer is attached to a PCIe SAS adapter (#EJ03) via PCIe x8 Cable (example: #EN05 or #EN07).
- The system maximum is two with one processor module and four with two processor modules with AIX or Linux.
- The system maximum is one with one processor module and two with two processor modules with IBM i.
The following list shows I/O drawers that are supported or available on the 8205 machine type and the correct interface to use for each of the drawers.
Order
Feature description status Interface
-------------------------------------- --------- --------
5796 PCI-X DDR 12X Exp Drawer Supported 12X
5802 PCIe 12X I/O Drawer (W/Disk Bays) Available 12X
5877 PCIe 12X I/O Drawer (No Disk Bays)Available 12X
5886 EXP12S SAS DASD Drawer Supported SAS
5887 EXP24S SAS DASD Drawer Available SAS
EDR1 EXP30 Ultra SSD I/O Drawer Available SAS
7214-1U2 Tape and DVD Enclosure Supported SAS/USB
7216-1U2 Tape and DVD Enclosure Available SAS
7314-G30 PCI-X DDR 12X I/O Drawer Supported 12X
Maximum number of attached I/O drawers per system:
Feature Power 740
------- -----------------
O/S AIX Linux IBM i
5796 8 8 8
5802 4 4 4
5877 4 4 4
5886 28 28 28
5887 14 14 14
EDR1 4 4 2
7214-1U2 6 6 6
7216-1U2 6 6 6
7314-G30 4 4 4
PCI card slots
The Power 740 (8205-E6D) contains five full-height, short, Gen2 8x, PCIe slots and one full-height, 4x, PCIe slot. An optional PCIe Adapter Riser Card feature 5685 adds four short, Gen2 8x, PCIe Low Profile slots. One GX++ slot is available when one processor module is installed in the system. A second GX++ slot is available when a second processor module is installed in the system. When feature 5685 is installed in the system, the number of GX++ slots available is reduced by one. Feature EJ04 can be installed in the GX++ slot. Feature number 5899 is required in the 8205-E6D minimum configuration and occupies the 4x slot.
Note: Optional 12X GX++ adapter is used for attaching I/O expansion drawers with PCI slots and, optionally, disk/SSD bays.
Note: Full-height PCIe adapters and low-profile PCIe adapters are not interchangeable. Even if the card was designed with low-profile dimensions, the tail stock at the end of the adapter is specific to either low-profile or full-height PCIe slots.
Graphics adapters
- A graphics adapter, keyboard, and mouse are not required in the minimum configuration.
- The maximum number of graphics adapters supported in the Power 740 CEC is five. Not supported under IBM i.
I/O adapters
- PCIe2 4-port 1 GbE Adapter (#5899) is in the 8205-E6D minimum configuration and occupies the 4x slot.
- All low-profile adapters can be installed in PCIe Adapter Riser Card (#5685).
- Two GX++ slots are available on the Power 740. The GX++ slot 1 does not share space with the CEC PCIe Low Profile adapter slots. The GX++ slot 2 shares space with the PCIe 4x slot. If a GX++ adapter is plugged into the 4x slot, then the feature 5899 required LAN adapter must occupy one of the five 8x slots, leaving four 8x slots available for other adapters.
- The GX++ adapter feature EJ04 is used for attaching feature 5802 or 5877 I/O drawers to the CEC.
Refer to Figure 2 for additional I/O adapter information.
Figure 2. I/O adapter features
Orderable Supported CEC Sys
feature feature Max Max
I/O adapter number number qty qty Size
----------- --------- --------- --- --- -----
PCIe LP RAID & SSD SAS A 2053 2 2 Short
PCIe RAID & SSD SAS 2054 2 2 Short
PCIe RAID & SSD SAS w/ BSC 2055 0 20 Short
4-port USB PCIe 2728 5 8 Short
2-port USB PCI 2738 0 48 Short
8-port Asynchronous EIA-232 2943 0 32 Short
4-port ARTIC960Hx 2947 0 48 Long
2-port Multiprotocol 2962 0 48 Short
GXT135P Graphics Accelerator 2849/1980 0 8 Short
PCIe 2-Line WAN w/Modem 2893 5 45 Short
PCIe 2-Line WAN w/Modem CIM 2894 5 45 Short
PCI-X Cryptographic Coprocessor 4764 0 48 Long
PCIe Crypto Coprocessor No BSC 4807 2 2 Short
PCIe Crypto Coprocessor Gen3 BSC 4808 0 8 Short
PCIe2 LP 4-port 1GbE Adapter 5260 4 4 LP
PCIe LP POWER GXT145 Graphics Acc 5269 4 4 LP
PCIe LP 10Gb FCoE 2-port Adapter 5270 4 4 LP
PCIe LP 4-Port 10/100/1000 Base-T 5271 4 4 LP
PCIe LP 10GbE CX4 1-port Adapter 5272 4 4 LP
PCIe LP 8Gb 2-Port Fibre Channel 5273 4 4 LP
PCIe LP 2-Port 1GbE SX Adapter 5274 4 4 LP
PCIe LP 10GbE SR 1-port Adapter 5275 4 4 LP
PCIe LP 4Gb 2-Port Fibre Channel 5276 4 4 LP
PCIe LP 4-Port Async EIA-232 Adap 5277 4 4 LP
PCIe LP 2-x4-port SAS Adapter 3Gb 5278 4 4 LP
PCIe2 LP 4-port 1/10GbE SFP+ 5279 4 4 LP
PCIe2 LP 4-port 1/10GbE SR 5280 4 4 LP
PCIe LP 2-Port 1GbE TX Adapter 5281 4 4 LP
PCIe2 LP PCIe2 2-port 4X IB QDR 5283 2 2 LP
PCIe2 LP PCIe2 2-port 10GbE SR 5284 4 4 LP
PCIe2 2-Port 4X IB QDR Adapter 5285 2 2 Short
PCIe2 LP PCIe2 2-Port 10GbE SFP 5286 4 4 LP
PCIe2 2-port 10GbE SR 5287 5 5 Short
PCIe2 2-port 10GbE SFP+ 5288 5 5 Short
PCIe2 2-Port Async EIA 232 5289 2 12 Short
PCIe LP 2-Port Async EIA 232 5290 2 2 LP
Gigabit Ethernet 5700/1978 0 48 Short
10/100/1000 Ethernet 5701/1979 0 48 Short
2-port 10/100/1000 Ethernet 5706 1983 0 48 Short
10 Gigabit FCoE PCIe Dual Port 5708 5 45 Short
ISCI TOE Gb Ethernet (Copper) 5713 1986 0 48 Short
ISCI TOE Gb Ethernet (Fiber) 5714/1987 0 48 Short
2 Gb Fibre Channel PCI-X 5716/1977 0 48 Short
4-port 1 Gb Ethernet PCI-e 4x 5717 5 45 Short
10 Gb Ethernet - Short Reach 5721 0 48 Short
10 Gb Ethernet - Long Reach 5722 0 48 Short
2-port Asynchronous EIA-232 5723 0 48 Short
PCIe2 8x 4-port Fibre Channel 5729 5 5 Short
10 Gigabit Ethernet-CX4 PCI Exp. 5732 5 45 Short
8 Gb Dual-port Fibre Channel 5735 5 45 Short
PCI-X Ultra320 SCSI DDR 5736 1912 0 48 Short
4-port 10/100/1000 Ethernet 5740/1954 0 48 Short
PCIe2 4-Port 10GbE/1GbE SR&RJ4 5744 5 5 Short
PCIe2 4-Port 10GbE/1GbE SFP+Cop 5745 5 5 Short
GXT145 PCIe Graphics Accelerator 5748 5 8 Short
2-port 4 Gbps Fibre Channel 5749 0 48 Short
1-port 4 Gb Fibre Channel 5758/1905 0 48 Short
2-port 4 Gb Fibre Channel 5759 1910 0 48 Short
2-port 1 Gb Ethernet (UTP) PCIe 5767 5 45 Short
2-port 1 Gb Ethernet (Fiber) PCIe 5768 5 45 Short
10 Gb Ethernet-SR 5769 5 45 Short
10 Gb Ethernet-LR 5772 5 45 Short
1-port 4 Gb Fibre Channel 5773 5 45 Short
2-port 4 Gb Fibre Channel 5774 5 45 Short
4-port Asynch EIA-232 PCIe 5785 5 45 Short
PCIe 380MB Cache Dual SAS RAID 5805 5 45 Short
PCIe2 4-port 1GbE Adapter 5899 6 46 Short
SAS Controller PCI-X 2.0 5900 0 48 Short
PCIe Dual-x4 SAS 5901 5 45 Short
PCI-X DDR Dual-x4 SAS RAID 5902 0 48 Long
PCI-X DDR SAS RAID Adapter (BSC) 5908 0 16 Long
PCI-X DDR Dual-x4 SAS 5912 0 48 Short
PCIe2 1.8GB Cache RAID SAS 5913 2 34 Short
PCI 2-line WAN IOA, no IOP 6805 0 48 Short
PCI 4-Modem WAN IOA, no IOP 6808 0 48 Short
PCI 4-Modem WAN IOA, no IOP, CIM 6809 0 48 Short
PCI 2-line WAN w/Modem, no IOP 6833 0 48 Short
PCI 2-line WAN w/Modem, no IOP, CIM 6834 0 48 Short
PCIe2 LP 2-Port 10GbE RoCE SFP+ EC27 4 4 LP
PCIe2 2-Port 10GbE RoCE SFP+ EC28 5 5 Short
PCIe2 LP 2-Port 10GbE RoCE SR EC29 4 4 LP
PCIe2 2-Port 10GbE RoCE SR EC30 5 5 Short
GX++ 2-port PCIe2 x8 Adapter EJ03 2 2 GX++
GX++ Dual-port 12x Chan Attach EJ04 2 2 GX++
PCIe2 16Gb 2-port Fibre Channel EN0A 5 5 Short
PCIe2 LP 16Gb 2-port Fibre ChannelEN0B 4 4 LP
PCIe2 4-port (10Gb FCoE & 1GbE) EN0H 5 5 Short
PCIe2 LP 4-port (10Gb FCoE&1GbE) EN0J 4 4 LP
PCIe2 LP 8Gb 4-port Fibre Channel EN0Y 4 4 LP
PCIe2 RAID SAS Adapter Dual-port ESA1 2 42 Short
PCIe2 LP RAID SAS 2-port 6Gb ESA2 2 2 LP
Note: All low-profile (LP) adapter cards require feature number 5685.
Storage devices/bays
- The Power 740 has a slim media bay that can contain an optional DVD-RAM (#5771 or follow-on) and a half-high bay that can contain a tape drive or removable disk drive.
- Either feature number 5618 or EJ01 must be selected.
- Feature number 5618 supports six small form-factor (SFF) disk units, either HDD or SSD. Split (3x3) drive bays supported with feature EJ02. No RAID 5 or 6 support. No IBM i support.
- Feature number EJ01 supports eight SFF disk units, either HDD or SSD. RAID 5 or 6 support. No split backplane.
- A valid orderable HDD or SSD is required in a minimum configuration. (No HDDs/SSDs are required in the CEC if feature number 0837 is selected.)
- If tape device feature 5619, 5638, or 5746 is installed in the half-high media bay, feature 3656 must be selected.
- Disk units can be placed in any slot at any time with or without a split backplane.
- A half-high tape feature and a feature 1103 Removable USB Disk Drive Docking Station are mutually exclusive. One or the other can be in the half-high bay in the system but not both. Feature 3656 is not required with feature 1103.
- Split storage backplane drive bay support requirements:
- Storage backplane feature 5618 with feature EJ02 supports 3 x 3 split drive bays.
- SAS-bay-based SSDs support restrictions:
- 3.5-inch features 3586 and 3587 are not supported in the Power 740 CEC.
- SSDs and HDDs are not allowed to mirror each other.
- SSDs are not supported by features 5278, 5900, 5901, 5902, and 5912.
- When an SSD is placed in feature EJ01, no feature 5886 or 5887 DASD drawer is allowed to connect to the system's external SAS port.
- When an SSD is placed in a feature 5886 or 5887 DASD drawer, the drawer is not allowed to connect to the system's external SAS port.
- A maximum of eight per feature 5886 drawer is allowed. No mixing of SSDs and HDDs is allowed in a feature 5886. A maximum of one feature 5886 EXP12S drawer containing SSDs attached to a single controller or pair of controllers is allowed. A feature 5886 containing SSD drives cannot be connected to other feature 5886s. A feature 5886 containing SSD drives cannot be attached to the CEC external SAS port on the Power 740.
- In a Power 740 with a split backplane, SSDs and HDDs may be placed in either "split," but no mixing of SSDs and HDDs within a split is allowed. IBM i does not support split backplane.
- In a Power 740 without a split backplane, SSDs and HDDs may be mixed in any combination. However, they cannot be in the same RAID array.
- HDD/SSD Data Protection -- if IBM i (#2145) is selected, one of
the following is required:
- Disk mirroring (default) -- requires feature 0040, 0043, or 0308
- SAN boot (#0837)
- RAID -- requires feature EJ01
- Mixed Data Protection (#0296)
Figure 3. Storage device features
Orderable Supported
Maximum feature feature
Device quantity Bay number number
------------- -------- --------- ------ ------
DVD-RAM (SATA) 1 Slim 5762
DVD-RAM (SATA) 1 Slim 5771
80/160 GB DAT160 Tape-SAS 1 Half high 5619
1.5T B/3.0 TB LTO-5 Tape-SAS 1 Half high 5638
800 GB/1.6 TB LTO4 Tape-SAS 1 Half high 5746
2.5/6TB LTO-6 Tape Drive 1 Half-high EU11
Internal Docking Station
for Removable Disk Drive 1 Half high 1103
External Docking Station
for Removable Disk Drive 1 USB Port 1104
RDX USB Internal Docking
Station for Removable
Disk Cartridge 1 Half high EU03
RDX SATA Internal Docking
Station for Removable
RDX USB External Docking
Station for Removable
Disk Cartridge 11 USB port EU04
Disk Cartridge 1 Half high EU07
Orderable Supported
Maximum feature feature
Device quantity Bay number number
------ --------------- --------------- ------ ------
AIX IBM i Linux
856 GB 10K, 0 44 0 SFF 1-8 1737
SAS, SFF 36 in 2 x #5802
856 GB 10K, 0 336 0 336 in 14 x #5887 1738
SAS, SFF, GEN2
900 GB 10K, 44 0 44 SFF 1-8, 1751
SAS, SFF 36 in 2 x #5802
900 GB 10K, 336 0 336 336 in 14 x #5887 1752
SAS, SFF, GEN2
177 GB SAS SFF, 80 0 80 SFF 1-8, 1775
SSD 72 in 4 x #5802
177 GB SAS SFF, 0 80 0 SFF 1-8, 1787
SSD 72 in 4 x #5802
600 GB 10K, 80 0 80 SFF 1-8, 1790
SAS, SFF 72 in 4 x #5802
177 GB SAS SFF, 336 0 336 336 in 14 x #5887 1793
SSD, GEN2
177 GB SAS SFF, 0 336 0 336 in 14 x #5887 1794
SSD, GEN2
283 GB 10K, 0 80 0 SFF 1-8 1879
SAS, SFF 72 in 4 x #5802
300 GB 10K, 80 0 80 SFF 1-8, 1880
SAS, SFF 72 in 4 x #5802
146.8 GB 15K, 80 0 80 SFF 1-8, 1882
SAS, SFF 72 in 4 x #5802
73.4 GB 15K, 80 0 80 SFF 1-8, 1883
SAS, SFF 72 in 4 x #5802
69.7 GB 15K, 0 80 0 SFF 1-8, 1884
SAS, SFF 72 in 4 x #5802
300 GB 10K, 80 0 80 SFF 1-8, 1885
SAS, SFF 72 in 4 x #5802
146.8 GB 15K, 80 0 80 SFF 1-8, 1886
SAS, SFF 72 in 4 x #5802
139.5 GB 15K, 0 80 0 SFF 1-8, 1888
SAS, SFF 72 in 4 x #5802
283 GB 10K 0 80 0 SFF 1-8, 1911
SAS, SFF 72 in 4 x #5802
571 GB 10K, 0 80 0 SFF 1-8, 1916
SAS, SFF 72 in 4 x #5802
146.8 GB, 15K, 336 0 336 336 in 14 x #5887 1917
SAS, SFF, GEN2
300 GB 10K, 336 0 336 336 in 14 x #5887 1925
SAS, SFF, GEN2
139 GB 15K, 0 336 0 336 in 14 x #5887 1947
SAS, SFF, GEN2
283 GB 15K, 0 336 0 336 in 14 x #5887 1948
SAS, SFF, GEN2
300 GB 15K, 336 0 336 336 in 14 x #5887 1953
SAS, SFF, GEN2
283 GB 10K, 0 336 0 336 in 14 x #5887 1956
SAS, SFF, GEN2
571 GB 10K, 0 336 0 336 in 14 x #5887 1962
SAS, SFF, GEN2
600 GB 10K, 336 0 336 336 in 14 x #5887 1964
SAS, SFF, GEN2
177 GB SAS, SFF, 8 0 8 2 per #2053, 1995
SDD #2054, #2055
177 GB SAS, SFF, 0 8 0 2 per #2053, 1996
SDD #2054, #2055
69 GB SAS, 3.5", 224 0 224 3586
Solid-state 224 in 28 x #5886
69 GB SAS, 3.5", 0 224 0 3587
Solid-state 224 in 28 x #5886
387 GB SAS SSD 120 0 120 Maximum 120 in 4 ES02
for #EDR1 x #EDR1
387 GB SAS SSD 0 60 0 Maximum 60 in 4 ES04
for #EDR1 x #EDR1
387 GB SAS SFF, 44 0 44 SFF 1-8, ES0A
SSD 36 in 2 x #5802
387 GB SAS SFF, 0 44 0 SFF 1-8, ES0B
SSD 36 in 2 x #5802
387 GB SAS SFF, 336 0 336 336 in 14 x #5887 ES0C
SSD, GEN2
387 GB SAS SFF, 0 336 0 336 in 14 x #5887 ES0D
SSD, GEN2
6 x #ES02 20 0 20 Maximum 120 in 4 ESR2
x #EDR1
6 x #ES04 0 10 0 Maximum 60 in 4 ESR4
x #EDR1
4 x #ES0A 1 0 1 4 in SFF 1-8 ESRA
or in 2 x #5802
4 x #ES0B 0 1 0 4 in SFF 1-8 ESRB
or in 2 x #5802
4 x #ES0C 1 0 1 4 in 14 x #5887 ESRC
4 x #ES0D 0 1 0 4 in 14 x #5887 ESRD
Notes
- Eight HDDs or SSDs maximum can be installed internally.
- A maximum of 336 Gen2 HDDs or SSDs can be installed in 14 x feature 5887.
- A maximum of 72 HDDs or SSDs can be installed in 4 x feature 5802.
- Feature 3586 and 3587 cannot be installed internally. Eight of feature 3586 or 3587 can be placed in each feature 5886.
- Maximum of ESRA+ESRB+ESRC+ESRD is 1.
Orderable Supported
Maximum feature feature
Device quantity Bay number number
---------------- --------------- ---------- --------- ---------
AIX IBM i Linux
73.4 GB 15K,RPM 336 0 336 28 x #5886 3646
SAS
146.8 GB 15K RPM, 336 0 336 28 x #5886 3647
SAS
300 GB 15K RPM, 336 0 336 28 x #5886 3648
SAS
450 GB 15K RPM, 336 0 336 28 x #5886 3649
SAS
69.8 GB 15K RPM, 0 336 0 28 x #5886 3676
SAS
139.6 GB 15K RPM, 0 336 0 28 x #5886 3677
SAS
283.8 GB 15K RPM, 0 336 0 28 x #5886 3678
SAS
428.4 GB 15K RPM, 0 336 0 28 x #5886 3658
SAS
Note: 3.5-inch DASD is not supported in the 8205-E6D CEC.
Hardware requirements
Power 740 minimum system configuration:
The Power 740 offers 6-, 8-, 12-, and 16-core configurations with one or two processor modules. The system can contain up to 1024 GB of system memory (256 GB maximum per memory riser card), six PCIe adapters in the base system with an additional four PCIe Low Profile adapters possible with the optional PCIe adapter riser card, and multiple media devices, as desired. This flexibility is made available through the many optional features for the Power 740.
Each Power 740 initial order must include a minimum of the following items:
- One system central electronics complex (CEC) enclosure with the
following items:
- Two power cords (#6458, #6460, #6469-#6478, #6488, #6489, #6491-#6494, #6496, #6577, #6580, #6651, #6653-#6660, #6665, #6669, #6671, #6672, or #6680)
- One Language Group, Specify (#9300 or #97xx)
- Choose one or two processor modules from:
- One or two 6-core 4.2 GHz POWER7+ processor modules (#EPCP)
- One or two 8-core 3.6 GHz POWER7+ processor modules (#EPCQ)
- One or two 8-core 4.2 GHz POWER7+ processor modules (#EPCR)
Note: If two processor modules are ordered, they must be the same feature number.
- Choose processor activations from:
- 6 x #EPDP, or 3 x #EPDP and 3 x #EPEP with processor module #EPCP
- 8 x #EPDQ, or 4 x #EPDQ and 4 x #EPEQ with processor module #EPCQ
- 8 x #EPDR, or 4 x #EPDR and 4 x #EPER with processor module #EPCR
Note:
- Features EPEN, EPEP, EPEQ, and EPER are part of IBM Editions.
- Processor activations are only available to SDIs as MES orders.
- Choose 8 GB minimum memory from:
- 8 GB (2 x 4 GB) Memory DIMMs, 1066 MHz, DDR3 (#EM08)
- 16 GB (2 x 8 GB) Memory DIMMs, 1066 MHz, DDR3 (#EM4B)
- 32 GB (2 x 16 GB) Memory DIMMs, 1066 MHz, DDR3 (#EM4C)
- 64 GB (2 x 32 GB) Memory DIMMs, 1066 MHz, DDR3 (#EM4D)
- Choose storage backplane from:
- 6 x SFF HDD or SSD/SATA DVD/Media backplane (#5618)
- 8 x SFF HDD or SSD/SATA DVD/Media backplane with Dual Write Cache RAID, and an external SAS port (#EJ01)
- One PCIe2 4-port 1 GbE Adapter (#5899)
Note: Takes up one PCIe slot.
- Choose HDD/SSD from any orderable SFF HDD or SSD: default is
146.8 GB SAS SFF HDD (#1886)
Notes:
- Features 1995 and 1996 require feature 2053, 2054, or 2055.
- When feature 2145, the IBM i operating system, is selected, a minimum of two HDD/SSD is required.
- No internal HDD/SSD is required if feature 0837 (Boot from SAN) is selected. In this case, a Fibre Channel or Fibre Channel over Ethernet adapter must also be ordered.
- Two 1925 watt ac power supplies (2 x #5532)
- Choose cover set from:
- IBM Rack-mount Drawer Bezel and Hardware (#7131)
- OEM Rack-mount Drawer Bezel and Hardware (#7132)
- Choose Primary Operating System Indicator from:
- IBM i (#2145 -- requires #0566 or #0567, and #0040)
- AIX (#2146)
- Linux (#2147)
Note: One nonfeaturized memory riser card is included in the base system. Three additional memory riser card features (#EM01) can be ordered.
RAID
Multiple protection options exist for HDD/SSD drives in the SAS SFF bays in Power 740 system unit or drives in 12X attached I/O drawers or drives in disk-only I/O drawers. Although protecting drives is always recommended, AIX/Linux users may choose to leave some or all drives unprotected at their own risk and IBM supports these configurations. IBM i configuration rules differ in this regard, and IBM supports IBM i partition configurations only when HDD/SSD drives are protected.
This HDD/SSD drive protection can be provided by AIX/IBM i/Linux software or by the HDD/SSD hardware controllers. Mirroring of drives is provided by AIX/IBM i/Linux software. In addition, AIX/Linux supports controllers providing RAID 0, 5, 6, or 10. IBM i integrated storage management already provides striping, so IBM i also supports controllers providing RAID 5 or 6. To further augment HDD/SSD protection, hot spare capability can be used for protected drives. Specific hot spare prerequisites apply.
An integrated SAS HDD/SSD controller is provided in the Power 740 system unit and is indicated by feature 5618 and provides support for JBOD and RAID 0, 1, and 10. Feature 5618 is optionally augmented by the ability to split the drive bays into two groups when feature EJ02 is added to the configuration. For even more function, feature EJ01 can be used instead of feature 5618 or feature 5618 plus EJ02. Feature EJ01 provides RAID 0, 1, 5, 6, and 10. AIX or Linux supports all of these options. IBM i does not use JBOD and uses imbedded functions instead of RAID 10, but does leverage the RAID 5 or 6 function of the integrated controllers. Other disk/SSD controllers are provided as PCI adapters. PCI-X SCSI, PCI-X SAS, and PCIe SAS adapters are supported. PCI Controllers with and without write cache are supported. RAID 5 and RAID 6 on controllers with write cache are supported with one exception. The PCIe RAID and SSD SAS Adapter has no write cache but supports RAID 5 and RAID 6.
AIX/Linux can use disk drives formatted with 512 byte blocks when being mirrored by the operating system. These disk drives must be reformatted to 528 byte sectors when used in RAID arrays. Although a small percentage of the drive's capacity is lost, additional data protection such as ECC and bad block detection is gained in this reformatting. For example, a 300 GB disk drive when reformatted provides around 283 GB. IBM i always uses drives formatted to 528 bytes. IBM Power SSDs are formatted to 528 bytes.
Software requirements
If installing the AIX operating system (one of these):
- AIX 7.1 with the 7100-02 Technology Level and Service Pack 2, or later
- AIX 6.1 with the 6100-08 Technology Level and Service Pack 2, or later
- AIX 6.1 with the 6100-07 Technology Level and Service Pack 7, or later (Planned availability March 29, 2013)
- AIX 6.1 with the 6100-06 Technology Level and Service Pack 11, or later (Planned availability March 29, 2013)
- AIX V5.3 with the 5300-12 Technology Level and Service Pack 7 or
later (planned availability May 31, 2013) (
Note: AIX 5.3 Service Extension is required.)
- AIX V7.1 with the 7100-00 Technology Level and Service Pack 9 or later
- AIX V7.1 with the 7100-01 Technology Level and Service Pack 7 or later
If installing the IBM i operating system (one of these):
- IBM i 7.1, or later
- IBM i 6.1 with i 6.1.1 machine code, or later (Planned availability March 8, 2013)
Note: Feature EB34 is required to have native I/O with IBM i 6.1 with machine code 6.1.1.
If installing the Linux operating system (one of these):
- SUSE Linux Enterprise Server 11 Service Pack 2, or later, with current maintenance updates available from SUSE to enable all planned functionality.
- Red Hat Enterprise Linux 6.4 for POWER, or later
Users should also update their systems with the latest Linux for Power service and productivity tools available at
If installing VIOS use VIOS 2.2.1.6 or 2.2.2.0
Java 1.4.2 on POWER7
There are unique considerations when running Java 1.4.2 on POWER7+. For best exploitation of the outstanding performance capabilities and most recent improvements of POWER7 technology, IBM recommends upgrading Java-based applications to Java 7, Java 6 or Java 5 whenever possible.
For more information, visit
Refer to the IBM Prerequisite website for software requirements for each feature number
https://www-912.ibm.com/e_dir/eServerPrereq.nsf
|
|
| Publications |
|
|
IBM Power Systems hardware documentation provides you with the following topical information:
- System overview
- Planning for the system
- Installing and configuring the system
- Working with consoles, terminals, and interfaces
- Managing system resources
- Working with operating systems and software applications
- Troubleshooting, service, and support
- Planning for the system
You can access the product documentation on a DVD (SK5T-7087) or at
The following information is shipped with the 8205-E6D:
- Power Hardware Information DVD (SK5T-7087)
- Installing the 8205-E6D
- Safety Information
- Statement of Warranty
Hardware documentation such as installation instructions, user's information, and service information is available to download or view at
AIX documentation can be found at the IBM AIX Information Center
The IBM Systems Information Center provides you with a single information center where you can access product documentation for IBM systems hardware, operating systems, and server software. Through a consistent framework, you can efficiently find information and personalize your access. The IBM Systems Information Center
|
|
| Features |
|
|
|
|
|
|
|
|
Features - No charge
- Languages
- (#9300) -Language Group Specify - US English
- (#9700) -Language Group Specify - Dutch
- (#9703) -Language Group Specify - French
- (#9704) -Language Group Specify - German
- (#9705) -Language Group Specify - Polish
- (#9706) -Language Group Specify - Norwegian
- (#9707) -Language Group Specify - Portuguese
- (#9708) -Language Group Specify - Spanish
- (#9711) -Language Group Specify - Italian
- (#9712) -Language Group Specify - Canadian French
- (#9714) -Language Group Specify - Japanese
- (#9715) -Language Group Specify - Traditional Chinese (Taiwan)
- (#9716) -Language Group Specify - Korean
- (#9718) -Language Group Specify - Turkish
- (#9719) -Language Group Specify - Hungarian
- (#9720) -Language Group Specify - Slovakian
- (#9721) -Language Group Specify - Russian
- (#9722) -Language Group Specify - Simplified Chinese (PRC)
- (#9724) -Language Group Specify - Czech
- (#9725) -Language Group Specify -- Romanian
- (#9726) -Language Group Specify - Croatian
- (#9727) -Language Group Specify -- Slovenian
- (#9728) -Language Group Specify - Brazilian Portuguese
- (#9729) -Language Group Specify - Thai
- Specify Codes
- (#9440) -New AIX License Core Counter
- (#9441) -New IBM i License Core Counter
- (#9442) -New Red Hat License Core Counter
- (#9443) -New SUSE License Core Counter
- (#9444) -Other AIX License Core Counter
- (#9445) -Other Linux License Core Counter
- (#9446) -3rd Party Linux License Core Counter
- (#9447) -VIOS Core Counter
- (#9449) - Other License Core Counter
Features - Chargeable
Special Features - Initial Orders
- Administrative
- (#0463) -SSD Placement Indicator (5802/5803)
- (#0464) -SSD Placement Indicator - 5886
- (#0465) -SSD Placement Indicator - 5887
- (#ESC0) -S&H - No Charge
- (#ESC6) -S&H-b
- Editions
- (#ELB9) -Power 740 AIX Solution Edition
- (#EU24) -Cognos on Power - Small
- (#EU25) -Cognos on Power - Large
- (#EU28) -25th Anniversary Edition
- Miscellaneous
- (#0444) -CBU Specify
- (#0710) -Balanced Warehouse Solution Indicator
- (#0712) Power Cloud Solution Integrated Solution Indicator for Order Routing
- (#1114) -Smart Analytics System routing indicator
- (#4929) -Power 740 Solution Edition for IBM i
- (#5000) -Software Preload Required
- (#8143) -Linux Software Preinstall
- (#8144) -Linux Software Preinstall (Business Partners)
- (#9461) -Month Indicator
- (#9462) -Day Indicator
- (#9463) -Hour Indicator
- (#9464) -Minute Indicator
- (#9465) -Qty Indicator
- (#9466) -Countable Member Indicator
- (#ECSS) -Integrated Solution Packing
- (#EHSS) -SPSS on Power Solution Indicator
- (#EUC0) -Software preload define
- (#EUC1) -Software preload define
- (#EUC2) -Software preload define
- (#EUC3) -Software preload define
- Power
- (#5532) -System AC Power Supply, 1925 W
- Processor
- (#2319) -Factory Deconfiguration of 1-core
- Rack Related
- (#1109) -IBM Ethernet Switch J48E
- (#1136) -Integrated Storage Controller w/ 24 - 600GB drives
- Services
- (#0456) -Customer Specified Placement
- (#ERF1) -RFID Tags for Servers, Compute Nodes, Chassis, Racks, and HMCs
- Solid State Drive
- (#ESR2) -Six ES02 387GB 1.8" SAS SSD for AIX/Linux with eMLC
- (#ESR4) -Six ES04 387GB 1.8" SAS SSD for IBM i with eMLC
- (#ESRA) -Four ES0A 387GB SFF-1 SSD for AIX/Linux with eMLC
- (#ESRB) -Four ES0B 387GB SFF-1 SSD for IBM i with eMLC
- (#ESRC) -Four ES0C 387GB SFF-2 SSD for AIX/Linux with eMLC
- (#ESRD) -Four ES0D 387GB SFF-2 SSD for IBM i with eMLC
- (#ESRE) -Four ES10 387GB SFF-1 SSD for AIX/Linux
- (#ESRF) -Four ES11 387GB SFF-1 SSD for IBM i
- (#ESRG) -Four ES19 387GB SFF-2 SSD for AIX/Linux
- (#ESRH) -Four ES1A 387GB SFF-2 SSD for IBM i
- (#ESRJ) -Six ES0J 387GB 1.8" SSD for AIX/Linux
- (#ESRK) -Six ES0K 387GB 1.8" SSD for IBM i
- Specify Codes
- (#0205) -RISC-to-RISC Data Migration One and only one rack indicator feature is required on all orders (#4650 to #4666).
- (#4650) -Rack Indicator-Not Factory Integrated
- (#4651) -Rack Indicator, Rack #1
- (#4652) -Rack Indicator, Rack #2
- (#4653) -Rack Indicator, Rack #3
- (#4654) -Rack Indicator, Rack #4
- (#4655) -Rack Indicator, Rack #5
- (#4656) -Rack Indicator, Rack #6
- (#4657) -Rack Indicator, Rack #7
- (#4658) -Rack Indicator, Rack #8
- (#4659) -Rack Indicator, Rack #9
- (#4660) -Rack Indicator, Rack #10
- (#4661) -Rack Indicator, Rack #11
- (#4662) -Rack Indicator, Rack #12
- (#4663) -Rack Indicator, Rack #13
- (#4664) -Rack Indicator, Rack #14
- (#4665) -Rack Indicator, Rack #15
- (#4666) -Rack Indicator, Rack #16
- (#5557) -System Console-Ethernet No IOP
- (#9169) -Order Routing Indicator-System Plant
Special Features - Plant and/or Field Installable
- Accessory
- (#EU19) -Cable Ties & Labels
- Adapters
- (#1905) -4 GB Single-Port Fibre Channel PCI-X 2.0 DDR Adapter
- (#1910) -4 GB Dual-Port Fibre Channel PCI-X 2.0 DDR Adapter
- (#1912) -PCI-X DDR Dual Channel Ultra320 SCSI Adapter
- (#1954) -4-Port 10/100/1000 Base-TX PCI-X Adapter
- (#1977) -2 Gigabit Fibre Channel PCI-X Adapter
- (#1978) -IBM Gigabit Ethernet-SX PCI-X Adapter
- (#1979) -IBM 10/100/1000 Base-TX Ethernet PCI-X Adapter
- (#1980) -POWER GXT135P Graphics Accelerator with Digital Support
- (#1983) -IBM 2-Port 10/100/1000 Base-TX Ethernet PCI-X Adapter
- (#1986) -1 Gigabit iSCSI TOE PCI-X on Copper Media Adapter
- (#1987) -1 Gigabit iSCSI TOE PCI-X on Optical Media Adapter
- (#2053) -PCIe LP RAID & SSD SAS Adapter 3Gb
- (#2054) -PCIe RAID & SSD SAS Adapter 3Gb
- (#2055) -PCIe RAID & SSD SAS Adapter 3Gb w/ Blind Swap Cassette
- (#2728) -4 port USB PCIe Adapter
- (#2738) -2-Port USB PCI Adapter
- (#2849) -POWER GXT135P Graphics Accelerator with Digital Support
- (#2893) -PCIe 2-Line WAN w/Modem
- (#2943) -8-Port Asynchronous Adapter EIA-232/RS-422, PCI bus
- (#2947) -IBM ARTIC960Hx 4-Port Multiprotocol PCI Adapter
- (#2962) -2-Port Multiprotocol PCI Adapter
- (#4764) -PCI-X Cryptographic Coprocessor (FIPS 4)
- (#4807) -PCIe Crypto Coprocessor No BSC 4765-001
- (#4808) -PCIe Crypto Coprocessor Gen3 BSC 4765-001
- (#5260) -PCIe2 LP 4-port 1GbE Adapter
- (#5269) -PCIe LP POWER GXT145 Graphics Accelerator
- (#5270) -PCIe LP 10Gb FCoE 2-port Adapter
- (#5271) -PCIe LP 4-Port 10/100/1000 Base-TX Ethernet Adapter
- (#5272) -PCIe LP 10GbE CX4 1-port Adapter
- (#5273) -PCIe LP 8Gb 2-Port Fibre Channel Adapter
- (#5274) -PCIe LP 2-Port 1GbE SX Adapter
- (#5275) -PCIe LP 10GbE SR 1-port Adapter
- (#5276) -PCIe LP 4Gb 2-Port Fibre Channel Adapter
- (#5277) -PCIe LP 4-Port Async EIA-232 Adapter
- (#5278) -PCIe LP 2-x4-port SAS Adapter 3Gb
- (#5279) -PCIe2 LP 4-Port 10GbE&1GbE SFP+ Copper&RJ45
- (#5280) -PCIe2 LP 4-Port 10GbE&1GbE SR&RJ45 Adapter
- (#5281) -PCIe LP 2-Port 1GbE TX Adapter
- (#5283) -PCIe2 LP 2-Port 4X IB QDR Adapter 40Gb
- (#5284) -PCIe2 LP 2-port 10GbE SR Adapter
- (#5285) -PCIe2 2-Port 4X IB QDR Adapter 40Gb
- (#5286) -PCIe2 LP 2-Port 10GbE SFP+ Copper Adapter
- (#5287) -PCIe2 2-port 10GbE SR Adapter
- (#5288) -PCIe2 2-Port 10GbE SFP+Copper Adapter
- (#5289) -2 Port Async EIA-232 PCIe Adapter
- (#5290) -PCIe LP 2-Port Async EIA-232 Adapter
- (#5700) -IBM Gigabit Ethernet-SX PCI-X Adapter
- (#5701) -IBM 10/100/1000 Base-TX Ethernet PCI-X Adapter
- (#5706) -IBM 2-Port 10/100/1000 Base-TX Ethernet PCI-X Adapter
- (#5708) -10Gb FCoE PCIe Dual Port Adapter
- (#5713) -1 Gigabit iSCSI TOE PCI-X on Copper Media Adapter
- (#5714) -1 Gigabit iSCSI TOE PCI-X on Optical Media Adapter
- (#5716) -2 Gigabit Fibre Channel PCI-X Adapter
- (#5717) -4-Port 10/100/1000 Base-TX PCI Express Adapter
- (#5721) -10 Gb Ethernet-SR PCI-X 2.0 DDR Adapter
- (#5722) -10 Gb Ethernet-LR PCI-X 2.0 DDR Adapter
- (#5723) -2-Port Asynchronous EIA-232 PCI Adapter
- (#5729) -PCIe2 8Gb 4-port Fibre Channel Adapter
- (#5732) -10 Gigabit Ethernet-CX4 PCI Express Adapter
- (#5735) -8 Gigabit PCI Express Dual Port Fibre Channel Adapter
- (#5736) -PCI-X DDR Dual Channel Ultra320 SCSI Adapter
- (#5740) -4-Port 10/100/1000 Base-TX PCI-X Adapter
- (#5744) -PCIe2 4-Port 10GbE&1GbE SR&RJ45 Adapter
- (#5745) -PCIe2 4-Port 10GbE&1GbE SFP+Copper&RJ45 Adapter
- (#5748) -POWER GXT145 PCI Express Graphics Accelerator
- (#5749) -4Gbps Fibre Channel (2-Port)
- (#5758) -4 GB Single-Port Fibre Channel PCI-X 2.0 DDR Adapter
- (#5759) -4 Gb Dual-Port Fibre Channel PCI-X 2.0 DDR Adapter
- (#5767) -2-Port 10/100/1000 Base-TX Ethernet PCI Express Adapter
- (#5768) -2-Port Gigabit Ethernet-SX PCI Express Adapter
- (#5769) -10 Gigabit Ethernet-SR PCI Express Adapter
- (#5772) -10 Gigabit Ethernet-LR PCI Express Adapter
- (#5773) -4 Gigabit PCI Express Single Port Fibre Channel Adapter
- (#5774) -4 Gigabit PCI Express Dual Port Fibre Channel Adapter
- (#5785) -4 Port Async EIA-232 PCIe Adapter
- (#5805) -PCIe 380MB Cache Dual - x4 3Gb SAS RAID Adapter
- (#5899) -PCIe2 4-port 1GbE Adapter
- (#5900) -PCI-X DDR Dual -x4 SAS Adapter
- (#5901) -PCIe Dual-x4 SAS Adapter
- (#5902) -PCI-X DDR Dual - x4 3Gb SAS RAID Adapter
- (#5908) -PCI-X DDR 1.5GB Cache SAS RAID Adapter (BSC)
- (#5912) -PCI-X DDR Dual - x4 SAS Adapter
- (#5913) -PCIe2 1.8GB Cache RAID SAS Adapter Tri-port 6Gb
- (#5922) -Non-paired SAS RAID indicator
- (#5923) -Non-paired PCIe SAS RAID Indicator
- (#5924) -Non-paired Indicator 5913 PCIe SAS RAID Adapter
- (#5925) -Shared EXP30 Indicator
- (#5927) -Remote EXP30 Indicator
- (#6446) -Dual-port 12X Channel Interface Attach - Short Run
- (#6457) -Dual-port 12X Channel Interface Attach-Long Run
- (#6805) -PCI 2-Line WAN IOA No IOP
- (#6808) -PCI 4-Modem WAN IOA No IOP
- (#6833) -PCI 2-Line WAN w/Modem NoIOP
- (#EC27) -PCIe2 LP 2-Port 10GbE RoCE SFP+ Adapter
- (#EC28) -PCIe2 2-Port 10GbE RoCE SFP+ Adapter
- (#EC29) -PCIe2 LP 2-Port 10GbE RoCE SR Adapter
- (#EC2M) -PCIe3 LP 2-port 10GbE NIC&RoCE SR Adapter
- (#EC2N) -PCIe3 2-port 10GbE NIC&RoCE SR Adapter
- (#EC37) -PCIe3 LP 2-port 10GbE NIC&RoCE SFP+ Copper Adapter
- (#EC38) -PCIe3 2-port 10GbE NIC&RoCE SFP+ Copper Adapter
- (#EC41) -PCIe2 LP 3D Graphics Adapter x1
- (#EC42) -PCIe2 3D Graphics Adapter x1
- (#EC2G) -PCIe2 LP 2-port 10GbE SFN6122F Adapter
- (#EC2H) -PCIe2 LP 2-port 10GbE SFN5162F Adapter
- (#EC2J) -PCIe2 2-port 10GbE SFN6122F Adapter
- (#EC2K) -PCIe2 2-port 10GbE SFN5162F Adapter
- (#EC30) -PCIe2 2-Port 10GbE RoCE SR Adapter
- (#EJ02) -Split Drive Bay Capability for #5618
- (#EJ03) -GX++ 2-port PCIe2 x8 Adapter
- (#EJ04) -GX++ Dual-port 12x Channel Attach
- (#EJ10) -PCIe3 SAS Tape/DVD Adapter Quad-port 6Gb x8
- (#EJ11) -PCIe3 LP SAS Tape/DVD Adapter Quad-port 6Gb x8
- (#EJ27) -PCIe Crypto Coprocessor No BSC 4765-001
- (#EJ28) -PCIe Crypto Coprocessor Gen3 BSC 4765-001
- (#EJ0J) -PCIe3 RAID SAS Adapter Quad-port 6Gb x8
- (#EJ0L) -PCIe3 12GB Cache RAID SAS Adapter Quad-port 6Gb x8
- (#EJ0M) - PCIe3 LP RAID SAS ADAPTER Quad-Port 6Gb x8
- (#EJS1) -Non-paired Indicator ESA3 PCIe SAS RAID Adapter
- (#EN13) -PCIe 1-port Bisync Adapter
- (#EN27) -2 Port Async EIA-232 PCIe Adapter
- (#EN28) -PCIe LP 2-Port Async EIA-232 Adapter
- (#EN29) -2 Port Async EIA-232 PCIe Adapter
- (#EN0A) -PCIe2 16Gb 2-port Fibre Channel Adapter
- (#EN0B) -PCIe2 LP 16Gb 2-port Fibre Channel Adapter
- (#EN0H) -PCIe2 4-port (10Gb FCoE & 1GbE) SR&RJ45
- (#EN0J) -PCIe2 LP 4-port (10Gb FCoE & 1GbE) SR&RJ45
- (#EN0K) -PCIe2 4-port (10Gb FCoE & 1GbE) SFP+Copper&RJ45
- (#EN0L) -PCIe2 LP 4-port(10Gb FCoE & 1GbE) SFP+Copper&RJ45
- (#EN0S) -PCIe2 4-Port (10Gb+1GbE) SR+RJ45 Adapter
- (#EN0T) -PCIe2 LP 4-Port (10Gb+1GbE) SR+RJ45 Adapter
- (#EN0U) -PCIe2 4-port (10Gb+1GbE) Copper SFP+RJ45 Adapter
- (#EN0V) -PCIe2 LP 4-port (10Gb+1GbE) Copper SFP+RJ45 Adapter
- (#EN0W) -PCIe2 2-port 10/1GbE BaseT RJ45 Adapter
- (#EN0X) -PCIe2 LP 2-port 10/1GbE BaseT RJ45 Adapter
- (#EN0Y) -PCIe2 LP 8Gb 4-port Fibre Channel Adapter
- (#ESA3) -PCIe2 1.8GB Cache RAID SAS Adapter Tri-port 6Gb CR
- (#ESA1) -PCIe2 RAID SAS Adapter Dual-port 6Gb
- (#ESA2) -PCIe2 LP RAID SAS Adapter Dual-port 6Gb
- Administrative
- (#0462) -SSD Placement Indicator - CEC
- (#0719) -Load Source Not in CEC
- (#B0LG) -ServicePac Not Selected
- (#B0LH) -Service Renewal Requested
- (#B0UQ) -SP WSU 3Y 24x7 SD
- (#B0VH) -SP HDR/MR POWER 3Y
- Cable
- (#0348) -V.24/EIA232 6.1m (20-Ft) PCI Cable
- (#0349) -V.24/EIA232 15.2m (50-Ft) PCI Cable
- (#0353) -V.35 6.1m (20-Ft) PCI Cable
- (#0354) -V.35 15.2m (50-Ft) PCI Cable
- (#0356) -V.36 6.1m (20-Ft) PCI Cable
- (#0359) -X.21 6.1m (20-Ft) PCI Cable
- (#0360) -X.21 15.2m (50-Ft) PCI Cable
- (#0365) -V.24/EIA232 (80-Ft) PCI Cable
- (#0368) -V.24/EIA232 20-Ft. PCI Cable with M3
- (#1010) -Modem Cable - Austria
- (#1011) -Modem Cable - Belgium
- (#1012) -Modem Cable - Africa
- (#1014) -Modem Cable - Italy
- (#1015) -Modem Cable - France
- (#1016) -Modem Cable - Germany
- (#1017) -Modem Cable - UK
- (#1018) -Modem Cable - Iceland/Sweden
- (#1021) -Modem Cable - Fin/Nor
- (#1022) -Modem Cable - Netherlands
- (#1023) -Modem Cable - Swiss
- (#1024) -Modem Cable - Denmark
- (#1025) -Modem Cable - US/Canada and General Use
- (#1111) -3m, Blue Cat5e Cable
- (#1112) -10m, Blue Cat5e Cable
- (#1113) -25m, Blue Cat5e Cable
- (#1115) -CAT5E Ethernet Cable, 3M GREEN
- (#1116) -CAT5E Ethernet Cable, 10M GREEN
- (#1118) -3m, Yellow Cat5e Cable
- (#1119) -10m, Yellow Cat5e Cable
- (#1121) -CAT5E Ethernet Cable, 25M YELLOW
- (#1141) -1-meter Cable for EXP4500 Switch
- (#1143) -3-meter Cable for EXP4500 Switch
- (#1148) -EX4500 10GB Optical Transceiver
- (#1827) -System port/UPS Conversion Cable
- (#1828) -1.5 Meter 12X to 4X Channel Conversion Cable
- (#1829) -0.6 Meter 12X Cable
- (#1830) -1.5 Meter 12X cable
- (#1834) -8.0 Meter 12X Cable
- (#1840) -3.0 Meter 12X Cable
- (#1841) -3 Meter 12X to 4X Channel Conversion Cable
- (#1854) -10 Meter 12X to 4X Enhanced Channel Conversion Cable
- (#1861) -0.6 Meter 12X DDR Cable
- (#1862) -1.5 Meter 12X DDR Cable
- (#1864) -8.0 Meter 12X DDR Cable
- (#1865) -3.0 Meter 12X DDR Cable
- (#2118) -Converter Cable, VHDCI to P, Mini-68 pin to 68 pin, 0.3M
- (#2456) -2M LC-SC 50 Micron Fiber Converter Cable
- (#2459) -2M LC-SC 62.5 Micron Fiber Converter Cable
- (#2861) -ARTIC960Hx 4-Port EIA-232 Cable
- (#2863) -ARTIC960Hx 4-Port X.21 Cable
- (#2864) -ARTIC960Hx 4-Port V.35 (DTE) Cable
- (#2934) -3M Asynchronous Terminal/Printer Cable EIA-232
- (#2936) -Asynchronous Cable EIA-232/V.24 3M
- (#2951) -Cable, V.24 / EIA-232
- (#2952) -Cable, V.35
- (#2953) -Cable, V.36 / EIA-499
- (#2954) -Cable, X.21
- (#3124) -Serial-to-Serial Port Cable for Drawer/Drawer-3.7M
- (#3125) -Serial-to-Serial Port Cable for Rack/Rack-8M
- (#3287) -1m, (3.3-ft) IB 40G Copper Cable QSFP/QSFP
- (#3288) -3m, (9.8-ft.) IB 40G Copper Cable QSFP/QSFP
- (#3289) -5m QDR IB/E'Net Copper Cable QSFP/QSFP
- (#3290) -10 meter Quad Data Rate InfiniBand Optical Cable, QSFP/ QSFP
- (#3293) -30 meter Quad Data Rate InfiniBand Optical Cable, QSFP/ QSFP
- (#3450) -SAS YO Cable 1.5m - HD 6Gb Adapter to Enclosure
- (#3451) -SAS YO Cable 3m - HD 6Gb Adapter to Enclosure
- (#3452) -SAS YO Cable 6m - HD 6Gb Adapter to Enclosure
- (#3453) -SAS YO Cable 10m - HD 6Gb Adapter to Enclosure
- (#3454) -SAS X Cable 3m - HD 6Gb 2-Adapter to Enclosure
- (#3455) -SAS X Cable 6m - HD 6Gb 2-Adapter to Enclosure
- (#3456) -SAS X Cable 10m - HD 6Gb 2-Adapter to Enclosure
- (#3457) -SAS YO Cable 15m - HD 3Gb Adapter to Enclosure
- (#3458) -SAS X Cable 15m - HD 3Gb 2-Adapter to Enclosure
- (#3652) -SAS Cable (EE) Drawer to Drawer 1M
- (#3653) -SAS Cable (EE) Drawer to Drawer 3M
- (#3654) -SAS Cable (EE) Drawer to Drawer 6M
- (#3656) -SAS SFF Cable
- (#3661) -SAS Cable (X) Adapter to SAS Enclosure, Dual Controller/ Dual Path 3M:
- (#3662) -SAS Cable (X) Adapter to SAS Enclosure, Dual Controller/ Dual Path 6M:
- (#3663) -SAS Cable (X) Adapter to SAS Enclosure, Dual Controller/ Dual Path 15M:
- (#3675) -SAS EX Cable 3m - Drawer to Drawer
- (#3680) -SAS EX Cable 6m - Drawer to Drawer
- (#3681) -3M SAS CABLE, ADPTR TO ADPTR (AA)
- (#3682) -6M SAS CABLE, ADPTR TO ADPTR (AA)
- (#3684) -SAS Cable (AE) Adapter to Enclosure, single controller/ single path 3M
- (#3685) -SAS Cable (AE) Adapter to Enclosure, single controller/ single path 6M
- (#3687) -SAS Cable (YI) System to SAS Enclosure, Single Controller/Dual Path 3M
- (#3688) -SAS Cable (AT) 0.6 Meter
- (#3689) -SAS AT Cable 0.6m - HD 6Gb Adapter to 12X Enclosure (AT)
- (#3691) -SAS Cable (YO) Adapter to SAS Enclosure, Single Controller/Dual Path 1.5 M
- (#3692) -SAS Cable (YO) Adapter to SAS Enclosure, Single Controller/Dual Path 3 M
- (#3693) -SAS Cable (YO) Adapter to SAS Enclosure, Single Controller/Dual Path 6 M
- (#3694) -SAS Cable (YO) Adapter to SAS Enclosure, Single Controller/Dual Path 15 M
- (#3925) -0.3M Serial Port Converter Cable, 9-Pin to 25-Pin
- (#3927) -Serial Port Null Modem Cable, 9-pin to 9-pin, 3.7M
- (#3928) -Serial Port Null Modem Cable, 9-pin to 9-pin, 10M
- (#3930) -System Serial Port Converter Cable
- (#4242) -1.8 M (6-ft) Extender Cable for Displays (15-pin D-shell to 15-pin D-shell)
- (#4256) -Extender Cable - USB Keyboards, 1.8M
- (#4276) -VGA to DVI Connection Converter
- (#5915) -SAS AA Cable 3m - HD 6Gb Adapter to Adapter
- (#5916) -SAS AA Cable 6m - HD 6Gb Adapter to Adapter
- (#5917) -SAS AA Cable 1.5m - HD 6Gb Adapter to Adapter
- (#5918) -SAS AA Cable 0.6m - HD 6Gb Adapter to Adapter
- (#5926) -SAS EX Cable 1.5m - Drawer to Drawer
- (#6001) -Power Control Cable (SPCN) - 2 meter
- (#6006) -Power Control Cable (SPCN) - 3 meter
- (#6007) -Power Control Cable (SPCN) - 15 meter
- (#6008) -Power Control Cable (SPCN) - 6 meter
- (#6029) -Power Control Cable (SPCN) - 30 meter
- (#6771) -Two 1M Intra-rack Fibre Channel Cables
- (#6773) -Two 3M Intra-rack Fibre Channel Cables
- (#7801) -Ethernet Cable, 6M, Hardware Management Console to System Unit
- (#7802) -Ethernet Cable, 15m, Hardware Management Console to System Unit
- (#ECB0) -0.6m (2.0-ft), Blue CAT5 Ethernet Cable
- (#ECB2) -1.5m (4.9-ft), Blue CAT5 Ethernet Cable
- (#ECBB) -SAS AT Cable 0.6m - HD Narrow 6Gb Adapter to 12X Enclosure (AT)
- (#ECBJ) -SAS X Cable 3m - HD Narrow 6Gb 2-Adapters to Enclosure
- (#ECBK) -SAS X Cable 6m - HD Narrow 6Gb 2-Adapters to Enclosure
- (#ECBL) -SAS X Cable 10m - HD Narrow 6Gb 2-Adapters to Enclosure
- (#ECBM) -SAS X Cable 15m - HD Narrow 3Gb 2-Adapters to Enclosure
- (#ECBT) -SAS YO Cable 1.5m - HD Narrow 6Gb Adapter to Enclosure
- (#ECBU) -SAS YO Cable 3m - HD Narrow 6Gb Adapter to Enclosure
- (#ECBV) -SAS YO Cable 6m - HD Narrow 6Gb Adapter to Enclosure
- (#ECBW) -SAS YO Cable 10m - HD Narrow 6Gb Adapter to Enclosure
- (#ECBX) -SAS YO Cable 15m - HD Narrow 3Gb Adapter to Enclosure
- (#ECBY) -SAS AE1 Cable 4m - HD Narrow 6Gb Adapter to Enclosure
- (#ECBZ) -SAS YE1 Cable 3m - HD Narrow 6Gb Adapter to Enclosure
- (#ECC0) -SAS AA Cable 0.6m - HD Narrow 6Gb Adapter to Adapter
- (#ECC2) -SAS AA Cable 1.5m - HD Narrow 6Gb Adapter to Adapter
- (#ECC3) -SAS AA Cable 3m - HD Narrow 6Gb Adapter to Adapter
- (#ECC4) -SAS AA Cable 6m - HD Narrow 6Gb Adapter to Adapter
- (#ECW0) -Optical Wrap Plug
- (#EN01) -1m (3.3-ft), 10GbE'Net Cable SFP+ Act Twinax Copper
- (#EN02) -3m (9.8-ft), 10Gb E'Net Cable SFP+ Act Twinax Copper
- (#EN03) -5m (16.4-ft), 10Gb E'Net Cable SFP+ Act Twinax Copper
- (#EN05) -PCIe x8 Cable 1.5m
- (#EN07) -PCIe x8 Cable 3m
- (#EQ02) -Quanity 150 of #3452 SAS YO Cable 6m - HD 6Gb Adapter to Enclosure
- (#EQ03) -Quantity 150 of #3453 SAS YO Cable 10m - HD 6Gb Adapter to Enclosure
- Disk
- (#1737) -856GB 10k RPM SAS SFF Disk Drive (IBM i)
- (#1738) -856GB 10k RPM SAS SFF-2 Disk Drive (IBM i)
- (#1751) -900GB 10K RPM SAS SFF Disk Drive (AIX/Linux)
- (#1752) -900GB 10k RPM SAS SFF-2 Disk Drive (AIX/Linux)
- (#1790) -600GB 10K RPM SAS SFF Disk Drive (AIX/Linux)
- (#1817) -Quantity 150 of #1962
- (#1818) -Quantity 150 of #1964
- (#1844) -Quantity 150 of #1956
- (#1866) -Quantity 150 of #1917
- (#1868) -Quantity 150 of #1947
- (#1869) -Quantity 150 of #1925
- (#1879) -283GB 15K RPM SAS SFF Disk Drive (IBM i)
- (#1880) -300GB 15K RPM SAS SFF Disk Drive (AIX/Linux)
- (#1882) -146.8GB 10K RPM SAS SFF Disk Drive
- (#1884) -69.7 GB 15K RPM SAS SFF Disk Drive
- (#1885) -300GB 10K RPM SFF SAS Disk Drive
- (#1886) -146GB 15K RPM SFF SAS Disk Drive (AIX/Linux)
- (#1888) -139GB 15K RPM SFF SAS Disk Drive (IBM i)
- (#1911) -283GB 10K RPM SFF SAS Disk Drive (IBM i)
- (#1916) -571GB 10k RPM SAS SFF Disk Drive (IBM i)
- (#1917) -146GB 15k RPM SAS SFF-2 Disk Drive (AIX/Linux)
- (#1925) -300GB 10k RPM SAS SFF-2 Disk Drive (AIX/Linux)
- (#1927) -Quantity 150 of #1948
- (#1929) -Quantity 150 of #1953
- (#1947) -139GB 15k RPM SAS SFF-2 Disk Drive (IBM i)
- (#1948) -283GB 15k RPM SAS SFF-2 Disk Drive (IBM i)
- (#1953) -300GB 15k RPM SAS SFF-2 Disk Drive (AIX/Linux)
- (#1956) -283GB 10k RPM SAS SFF-2 Disk Drive (IBM i)
- (#1962) -571GB 10k RPM SAS SFF-2 Disk Drive (IBM i)
- (#1964) -600GB 10k RPM SAS SFF-2 Disk Drive (AIX/Linux)
- (#3646) -73GB 15K RPM SAS Disk Drive
- (#3647) -146GB 15K RPM SAS Disk Drive (AIX/Linux)
- (#3648) -300GB 15K RPM SAS Disk Drive (AIX/Linux)
- (#3649) -450GB 15K RPM SAS Disk Drive (AIX/Linux)
- (#3658) -428GB 15K RPM SAS Disk Drive (IBM i)
- (#3676) -69.7GB 15k rpm SAS Disk Drive
- (#3677) -139.5GB 15k rpm SAS Disk Drive (IBM i)
- (#3678) -283.7GB 15k rpm SAS Disk Drive (IBM i)
- (#7517) -Quantity 150 of #3676
- (#7518) -Quantity 150 of #3677
- (#7519) -Quantity 150 of #3678
- (#7538) -Quantity 150 of #3658
- (#7549) -Quantity 150 of #3647
- (#7564) -Quantity 150 of #3648
- (#7565) -Quantity 150 of #3649
- (#ELS1) -#ES11 Load Source Specify (387GB SSD SFF-1)
- (#ELS9) -#ES1A Load Source Specify (387GB SSD SFF-2)
- (#EQ38) -Quantity 150 of #1738 (856GB SFF-2 disk)
- (#EQ52) -Quantity 150 of #1752 (900GB SFF-2 disk)
- (#EQD2) -Quantity 150 of #ESD2 (1.1TB 10k SFF-2)
- (#EQD3) -Quantity 150 of #ESD3 (1.2TB 10k SFF-2)
- (#EQDN) -Quantity 150 of #ESDN (571GB 15K RPM SAS SFF-2 for IBM i)
- (#EQDP) -Quantity 150 of #ESDP (600GB 15K RPM SAS SFF-2 for AIX/ LINUX)
- (#ELSJ) -#ESDJ Load Source Specify (571GB 15K RPM SFF-1 )
- (#ELSN) -#ESDN Load Source Specify (571GB 15K RPM SFF-2 )
- (#ESD0) -1.1TB 10K RPM SAS SFF-1 Disk Drive (IBM i)
- (#ESD1) -1.2TB 10K RPM SAS SFF-1 Disk Drive (AIX/Linux)
- (#ESD2) -1.1TB 10K RPM SAS SFF-2 Disk Drive (IBMi)
- (#ESD3) -1.2TB 10K RPM SAS SFF-2 Disk Drive (AIX/Linux)
- (#ESDJ) -571GB 15K RPM SAS SFF-1 Disk Drive - 528 Block (IBM i)
- (#ESDK) -600GB 15K RPM SAS SFF-1 Disk Drive - 5xx Block (AIX/Linux)
- (#ESDN) -571GB 15K RPM SAS SFF-2 Disk Drive - 528 Block
- (#ESDP) -600GB 15K RPM SAS SFF-2 Disk Drive - 5xx Block
- Display
- (#3632) -Widescreen LCD Monitor
- (#3637) -IBM T541H /L150p 15" TFT Color Monitor
- (#3639) -IBM ThinkVision L170p Flat Panel Monitor
- (#3640) -ThinkVision L171p Flat Panel Monitor
- (#3641) -IBM T115 Flat Panel Monitor
- (#3642) -ThinkVision L191p Flat Panel Monitor
- (#3643) -IBM T120 Flat Panel Monitor
- (#3644) -IBM T119 Flat Panel Monitor
- (#3645) -IBM T117 Flat Panel Monitor
- Drive
- (#1103) -USB Internal Docking Station for Removable Disk Drive
- (#1104) -USB External Docking Station for Removable Disk Drive
- (#1106) -USB 160 GB Removable Disk Drive
- (#1107) -USB 500 GB Removable Disk Drive
- (#EU01) -1TB Removable Disk Drive Cartridge
- (#EU03) -RDX USB Internal Docking Station for Removable Disk Cartridge
- (#EU04) -RDX USB External Docking Station for Removable Disk Cartridge
- (#EU07) -RDX SATA Internal Docking Station for Removable Disk Cartridge
- (#EU08) -RDX 320 GB Removable Disk Drive
- (#EU15) -1.5TB Removable Disk Drive Cartridge
- (#EU17) -2.5 TB LTO-6 Tape Cartridge
- (#EU18) -5-Pack of #EU17
- (#EU2T) -2TB Removable Disk Drive Cartridge (RDX)
- Keyboards
- (#5951) -Full Width Keyboard -- USB, US English, #103P
- (#5952) -Full Width Keyboard -- USB, French, #189
- (#5953) -Full Width Keyboard -- USB, Italian, #142
- (#5954) -Full Width Keyboard -- USB, German/Austrian, #129
- (#5955) -Full Width Keyboard -- USB, UK English, #166P
- (#5956) -Full Width Keyboard -- USB, Spanish, #172
- (#5957) -Full Width Keyboard -- USB, Japanese, #194
- (#5958) -Full Width Keyboard -- USB, Brazilian Portuguese, #275
- (#5959) -Full Width Keyboard -- USB, Hungarian, #208
- (#5960) -Full Width Keyboard -- USB, Korean, #413
- (#5961) -Full Width Keyboard -- USB, Chinese, #467
- (#5962) -Full Width Keyboard -- USB, French Canadian, #445
- (#5964) -Full Width Keyboard -- USB, Belgian/UK, #120
- (#5965) -Full Width Keyboard -- USB, Swedish/Finnish, #153
- (#5966) -Full Width Keyboard -- USB, Danish, #159
- (#5967) -Full Width Keyboard -- USB, Bulgarian, #442
- (#5968) -Full Width Keyboard -- USB, Swiss/French/German, #150
- (#5969) -Full Width Keyboard -- USB, Norwegian,#155
- (#5970) -Full Width Keyboard -- USB, Dutch, #143
- (#5971) -Full Width Keyboard -- USB, Portuguese, #163
- (#5972) -Full Width Keyboard -- USB, Greek, #319
- (#5973) -Full Width Keyboard -- USB, Hebrew, #212
- (#5974) -Full Width Keyboard -- USB, Polish, #214
- (#5975) -Full Width Keyboard -- USB, Slovakian, #245
- (#5976) -Full Width Keyboard -- USB, Czech, #243
- (#5977) -Full Width Keyboard -- USB, Turkish, #179
- (#5978) -Full Width Keyboard -- USB, LA Spanish, #171
- (#5979) -Full Width Keyboard -- USB, Arabic, #253
- (#5980) -Full Width Keyboard -- USB, Thai, #191
- (#5981) -Full Width Keyboard -- USB, Russian, #443
- (#5982) -Full Width Keyboard -- USB, Slovenian, #234
- (#5983) -Full Width Keyboard -- USB, US English Euro, #103P
- (#EK51) -Full Width Keyboard -- USB, US English, #103P
- (#EK52) -Full Width Keyboard -- USB, French, #189
- (#EK53) -Full Width Keyboard -- USB, Italian, #142
- (#EK54) -Full Width Keyboard -- USB, German/Austrian, #129
- (#EK55) -Full Width Keyboard -- USB, UK English, #166P
- (#EK56) -Full Width Keyboard -- USB, Spanish, #172
- (#EK57) -Full Width Keyboard -- USB, Japanese, #194
- (#EK58) -Full Width Keyboard -- USB, Brazilian Portuguese, #275
- (#EK59) -Full Width Keyboard -- USB, Hungarian, #208
- (#EK60) -Full Width Keyboard -- USB, Korean, #413
- (#EK61) -Full Width Keyboard -- USB, Chinese, #467
- (#EK62) -Full Width Keyboard -- USB, French Canadian, #445
- (#EK64) -Full Width Keyboard -- USB, Belgian/UK, #120
- (#EK65) -Full Width Keyboard -- USB, Swedish/Finnish, #153
- (#EK66) -Full Width Keyboard -- USB, Danish, #159
- (#EK67) -Full Width Keyboard -- USB, Bulgarian, #442
- (#EK68) -Full Width Keyboard -- USB, Swiss/French/German, #150
- (#EK69) -Full Width Keyboard -- USB, Norwegian,#155
- (#EK70) -Full Width Keyboard -- USB, Dutch, #143
- (#EK71) -Full Width Keyboard -- USB, Portuguese, #163
- (#EK72) -Full Width Keyboard -- USB, Greek, #319
- (#EK73) -Full Width Keyboard -- USB, Hebrew, #212
- (#EK74) -Full Width Keyboard -- USB, Polish, #214
- (#EK75) -Full Width Keyboard -- USB, Slovakian, #245
- (#EK76) -Full Width Keyboard -- USB, Czech, #243
- (#EK77) -Full Width Keyboard -- USB, Turkish, #179
- (#EK78) -Full Width Keyboard -- USB, LA Spanish, #171
- (#EK79) -Full Width Keyboard -- USB, Arabic, #253
- (#EK80) -Full Width Keyboard -- USB, Thai, #191
- (#EK81) -Full Width Keyboard -- USB, Russian, #443
- (#EK82) -Full Width Keyboard -- USB, Slovenian, #234
- (#EK83) -Full Width Keyboard -- USB, US English Euro, #103P
- Linecords
- (#1406) -200V 16A 4.3m (14-Ft) TL Line Cord
- (#1408) -4.3m 200V/16A Pwr Cd Italy
- (#1413) -125V 4.3m (14-Ft) Line Cord
- (#1414) -200V 1.8m (6-Ft) Locking Line Cord
- (#1418) -4.3m 200V/16A Power Cord S. Africa
- (#1419) -4.3m 200V/16A Power Cord Israel
- (#1420) -4.3m 200V/16A Power Cord EU/Asia
- (#1421) -4.3m 200V/16A Power Cord CH/DK
- (#1426) -200V 4.3m (14-Ft) Locking Line Cord
- (#1439) -4.3m 200V/10A Power Cord EU/Asia
- (#1440) -4.3m 200V/10A Power Cord Denmark
- (#1441) -4.3m 200V/10A Power Cord S. Africa
- (#1442) -4.3m 200V/10A Power Cord Swiss
- (#1443) -4.3m 200V/10A Power Cord UK
- (#1445) -4.3m 200V/10A Power Cord Israel
- (#1449) -4.3m 200V/32A Power Cord EU 1-PH
- (#1450) -4.3m 200V/16A Power Cord EU 2-PH
- (#1476) -4.3m 200V/12A Pwr Cd UK
- (#1477) -4.3m 200V/16A Pwr Cd
- (#6458) -Power Cord 4.3m (14-ft), Drawer to Wall/IBM PDU (250V/ 10A)
- (#6460) -Power Cord 4.3m (14-ft), Drawer To OEM PDU (125V, 15A)
- (#6469) -Power Cord 4.3m (14-ft), Drawer to Wall/OEM PDU (250V/ 15A) U. S.
- (#6470) -Power Cord 1.8m (6-ft), Drawer to Wall (125V/15A)
- (#6471) -Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU (125V/ 15A)
- (#6472) -Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU (250V/ 16A)
- (#6473) -Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU (250V/ 10A)
- (#6474) -Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/ 13A)
- (#6475) -Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/ 16A)
- (#6476) -Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/ 10A)
- (#6477) -Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/ 16A)
- (#6478) -Power Cord 2.7 M(9-foot), To Wall/OEM PDU, (250V, 16A)
- (#6479) -Power Cord (9-foot), To Wall/OEM PDU, (250V, 10A)
- (#6488) -Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (125V/ 15A or 250V/10A )
- (#6489) -4.3m (14-Ft) 3PH/24A 380-415V Power Cord
- (#6491) -4.3m (14-Ft) 1PH/48A 200-240V Power Cord
- (#6492) -4.3m (14-Ft) 1PH/48-60A 200-240V Power Cord
- (#6493) -Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/ 10A)
- (#6494) -Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/ 10A)
- (#6495) -Power Cord (9-foot), To Wall/OEM PDU, (250V, 10A)
- (#6496) -Power Cord 2.7M (9-foot), To Wall/OEM PDU, (250V, 10A)
- (#6497) -Power Cord (6-foot), To Wall/OEM PDU, (250V, 10A)
- (#6498) -Power Cord (6-foot), To Wall/OEM PDU, (250V, 15A)
- (#6577) -Power Cable - Drawer to IBM PDU, 200-240V/10A
- (#6651) -Power Cord 2.7M (9-foot), To Wall/OEM PDU, (125V, 15A)
- (#6653) -4.3m (14-Ft) 3PH/16A 380-415V Power Cord
- (#6654) -4.3m (14-Ft) 1PH/24-30A Pwr Cord
- (#6655) -4.3m (14-Ft) 1PH/24-30A WR Pwr Cord
- (#6656) -4.3m (14-Ft)1PH/24A Power Cord
- (#6657) -4.3m (14-Ft) 1PH/24A Power Cord
- (#6659) -Power Cord 2.7M (9-foot), To Wall/OEM PDU, (250V, 15A)
- (#6660) -Power Cord 4.3m (14-ft), Drawer to Wall/OEM PDU (125V/ 15A)
- (#6665) -Power Cord 2.8m (9.2-ft), Drawer to Wall/IBM PDU, (250V/ 10A)
- (#6669) -Power Cord 4.3M (14-foot), Drawer to OEM PDU, (250V, 15A)
- (#6670) -Power Cord (6-foot), To Wall (125V, 15A), PT #59
- (#6671) -Power Cord 2.7M (9-foot), Drawer to IBM PDU, 250V/10A
- (#6672) -Power Cord 2M (6.5-foot), Drawer to IBM PDU, 250V/10A
- (#6680) -Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/ 10A)
- (#6687) -Power Cord (6-foot), To Wall, (250V, 15A)
- (#ELC0) -PDU Access Cord 0.38m
- Manufacturing Instruction
- (#9359) -specify mode-1 1(1)5901/5278 for EXP24S #5887
- (#9360) -Specify mode-1 1(2)5901/5278 for EXP24S #5887
- (#9361) -Specify mode-2 1(2)5901/5278 for EXP24S #5887
- (#9365) -Specify mode-4 1(4)5901/5278 for EXP24S #5887
- (#9366) -Specify mode-2 1(4)5901/5278 for EXP24S #5887
- (#9367) -Specify mode-1 1(2)5903/5805 for EXP24S #5887
- (#9368) -Specify mode-2 1(4)5903/5805 for EXP24S #5887
- (#9382) -Specify mode-1 1(1)5904/6/8 for EXP24S #5887
- (#9383) -Specify mode-1 1(2) 5904/6/8 for EXP24S #5887
- (#9384) -Specify mode-1 & CEC SAS port for EXP24 #5887
- (#9385) -Specify mode-1 1(2) 5913 for EXP24S #5887
- (#9386) -Specify mode-2 1(4) 5913 for EXP24S #5887
- (#9388) -Specify Mode-1 & EXP30 for 1 EXP24S #5887
- (#EJP1) -Specify Mode-1 1(1)ESA1/ESA2 for EXP24S #5887
- (#EJP2) -Specify Mode-1 1(2)ESA1/ESA2 for EXP24S #5887
- (#EJP3) Specify Mode-2 1(2)ESA1/ESA2 1(2) X for EXP24S #5887 or #EL1S
- (#EJP4) -Specify Mode-2 1(4)ESA1/ESA2 for EXP24S #5887
- (#EJP5) -Specify Mode-4 1(4)ESA1/ESA2 for EXP24S #5887
- (#EJP6) Specify Mode-2 1(1)ESA1/ESA2 1(2) YO for EXP24S #5887 or #EL1S
- (#EJP7) Specify Mode-2 (2 )ESA1/ESA2 1(2) YO for EXP24 #5887 or #EL1S
- (#EJPA) Specify mode-2 (1) ESA1/ESA2 1(1) YO for EXP24 #5887 or #EL1S
- (#EJPB) Specify mode-2 (2)ESA1/ESA2 1(1) X for EXP24#5887 or #EL1S
- (#EJPC) -Specify mode-4 (1)ESA1/ESA2 for EXP24 #5887
- (#EJPD) -Specify mode-4 (2)ESA1/ESA2 for EXP24 #5887
- (#EJPE) -Specify mode-4 (3)ESA1/ESA2 for EXP24 #5887
- (#EJPJ) -Specify mode-2 (1)5901/5278 for EXP24 #5887
- (#EJPK) -Specify mode-2 (2)5901/5278 for EXP24 #5887
- (#EJPL) -Specify mode-4 (1)5901/5278 for EXP24 #5887
- (#EJPM) -Specify mode-4 (2)5901/5278 for EXP24 #5887
- (#EJPN) -Specify mode-4 (3)5901/5278 for EXP24 #5887
- (#EJPR) -Specify mode-2 (2)5903/5805 for EXP24 #5887
- (#EJPT) -Specify mode-2 (2)5913 for EXP24 #5887
- (#EJPY) -Specify Left Half 12X I/O Drawer to ESA1/ESA2
- (#EJPZ) -Specify Right Half 12X I/O Drawer to ESA1/ESA2
- (#EJR1) -Specify Mode-1 1(1)EJ0J/EJ0M/EL3B for EXP24S (#5887/EL1S)
- (#EJR2) -Specify Mode-1 1(2)EJ0J/EJ0M/EL3B for EXP24S (#5887/EL1S)
- (#EJR3) Specify Mode-2 1(2)EJ0J/EJ0M/EL3B 1(2) X for EXP24S (#5887/EL1S)
- (#EJR4) -Specify Mode-2 1(4)EJ0J/EJ0M/EL3B for EXP24S (#5887/EL1S)
- (#EJR5) -Specify Mode-4 1(4)EJ0J/EJ0M/EL3B for EXP24S (#5887/EL1S)
- (#EJR6) Specify Mode-2 1(1)EJ0J/EJ0M/EL3B 1(2) YO for EXP24S (#5887/EL1S)
- (#EJR7) Specify Mode-2 1(2)EJ0J/EJ0M/EL3B 1(2) YO for EXP24S (#5887/EL1S)
- (#EJRA) Specify Mode-2 1(1)EJ0J/EJ0M/EL3B 1(1) YO for EXP24S (#5887/El1S)
- (#EJRB) Specify Mode-2 1(2)EJ0J/EJ0M/EL3B 1(1) X for EXP24S (#5887/EL1S)
- (#EJRC) -Specify Mode-4 1(1)EJ0J/EJ0M/EL3B for EXP24S (#5887/EL1S)
- (#EJRD) -Specify Mode-4 1(2)EJ0J/EJ0M/EL3B for EXP24S (#5887/EL1S)
- (#EJRE) -Specify Mode-4 1(3)EJ0J/EJ0M/EL3B for EXP24S (#5888/EL1S)
- (#EJRP) -Specify Mode-1 1(2)EJ0L for EXP24S (#5887/EL1S)
- (#EJRR) -Specify mode-2 1(4) EJ0L for EXP24S #5887/EL1S
- (#EJRS) Specify Mode-2 1(2)EJ0L 1(2) X for EXP24S (#5887/EL1S)
- (#EJRT) Specify Mode-2 1(2)EJ0L 1(1) X for EXP24S (#5887/EL1S)
- (#EJRU) -Non-paired Indicator EJ0L PCIe SAS RAID Adapter
- (#EJRW) -Specify Left Half 12X I/O Drawer to PCIe3 12GB RAID SAS Adapter
- (#EJRX) -Specify Right Half 12X I/O Drawer to PCIe3 12GB RAID SAS Adapter
- (#EJRY) -Specify Left Half 12X I/O Drawer to PCIe3 RAID SAS Adapter
- (#EJRZ) -Specify Right Half 12X I/O Drawer to PCIe3 RAID SAS Adapter
- (#EJS2) -Specify Mode-2 1(2)ESA3 for EXP24S (#5887/#EL1S)
- (#EJS3) -Specify Mode-1 1(2)ESA3 for EXP24S (#5887/#EL1S)
- (#EJS4) -Specify Mode-2 1(4)ESA3 for EXP24S (#5887/#EL1S)
- (#EJS5) -Specify Left Half 12X I/O Drawer to PCIe2 1.8GB RAID SAS Adapter
- (#EJS6) -Specify Right Half 12X I/O Drawer to PCIe2 1.8GB RAID SAS Adapter
- Media Devices
- (#5618) -Storage Backplane -- 6 SFF Bays/ SATA DVD/HH Tape
- (#5619) -80/160GB DAT160 SAS Tape Drive
- (#5638) -1.5TB/3.0TB LTO-5 SAS Tape Drive
- (#5746) -Half High 800GB/1.6TB LTO4 SAS Tape Drive
- (#5762) -SATA Slimline DVD-RAM Drive
- (#5771) -SATA Slimline DVD-RAM Drive
- (#EJ01) -Storage Backplane -- 8 SFF Bays/175MB RAID/Dual IOA
- (#EU11) -2.5/6.25TB LTO-6 SAS Tape Drive, Half-high
- (#EU16) -80/160GB DAT160 USB Tape Drive
- Media Supplies
- (#5689) -DAT160 Data Cartridge
- (#5747) -IBM LTO Ultrium 4 800 GB Data Cartridge
- Memory
- (#4794) -Power Active Memory Expansion Enablement
- (#EM01) -Memory Riser Card
- (#EM08) -8GB (2x4GB) Memory DIMMs, 1066 MHz, 2Gb DDR3 DRAM
- (#EM4B) -16GB (2x8GB) Memory DIMMs, 1066 MHz, 4Gb DDR3 DRAM
- (#EM4C) -32GB (2x16GB) Memory DIMMs, 1066 MHz, 4Gb DDR3 DRAM
- (#EM4D) -64GB (2x32GB) Memory DIMMs, 1066 MHz, 4Gb DDR3 DRAM
- Miscellaneous
- (#0004) -EMEA Bulk MES Indicator
- (#0098) -Special Manufacturing Operations Indicator
- (#2145) -Primary OS - IBM i
- (#2146) -Primary OS - AIX
- (#2147) -Primary OS - Linux
- (#4367) -Package 5X #2055 & 20X #1995 (AIX/Linux)
- (#4377) -Package 5X #2055 & 20X #1996 (IBM i)
- (#5685) -PCIe Riser Card (Gen2)
- (#6586) -Modem Tray for 19-Inch Rack
- (#EB2W) -EXP30 Carrier for 1.8-inch SSD
- (#ECSC) -Custom Service Specify, Shenzhen, China
- (#ECSM) -Custom Service Specify, Mexico
- (#ECSP) -Custom Service Specify, Poughkeepsie, USA
- (#EHK1) -DSW Order Specify Code
- (#EHK2) -Solution Specify Code
- (#EU29) -Order Placed Indicator
- Pointing Device
- (#8841) -Mouse - USB, with Keyboard Attachment Cable
- (#8845) -USB Mouse
- Power
- (#5160) -Power Dist Unit 1 Phase NEMA
- (#5161) -Power Dist Unit 1 Phase IEC
- (#5162) -Power Dist Unit 2 of 3 Phase
- (#5163) -Power Dist Unit - 3 Phase
- (#6260) -Redundant or Base Power Supply for 7031 Model D24/T24 I/ O Enclosure
- (#6261) -Power Supply for 7031 Model D24/T24 I/O Enclosure
- (#7109) -Intelligent PDU+, 1 EIA Unit, Universal UTG0247 Connector
- (#7188) -Power Distribution Unit
- Processor
- (#4970) -One Processor of 5250 Enterprise Enablement
- (#4973) -One Processor of 5250 Enterprise Enablement for Solution Edition
- (#4974) -Full 5250 Enterprise Enablement
- (#EPCP) -6-core 4.2 GHz POWER7+ Processor Module
- (#EPCQ) -8-core 3.6 GHz POWER7+ Processor Module
- (#EPCR) -8-core 4.2 GHz POWER7+ Processor Module
- (#EPDP) -One Processor Activation for Processor Feature #EPCP
- (#EPDQ) -One Processor Activation for Processor Feature #EPCQ
- (#EPDR) -One Processor Activation for Processor Feature #EPCR
- (#EPEP) -Zero-priced Processor Activation for #EPCP
- (#EPEQ) -Zero-priced Processor Activation for #EPCQ
- (#EPER) -Zero-priced Processor Activation for #EPCR
- Rack Related
- (#0551) -19 inch, 1.8 meter high rack
- (#0553) -19 inch, 2.0 meter high rack
- (#0555) -19 inch, 1.3 meter high rack
- (#0599) -Rack Filler Panel Kit
- (#1135) -Integrated Storage Controller
- (#5796) -PCI-DDR 12X Expansion Drawer
- (#5802) -12X I/O Drawer PCIe, SFF disk
- (#5877) -12X I/O Drawer PCIe, No Disk
- (#5886) -EXP 12S Expansion Drawer
- (#5887) -EXP24S SFF Gen2-bay Drawer
- (#6068) -Opt Front Door for 1.8m Rack
- (#6069) -Opt Front Door for 2.0m Rack
- (#6248) -1.8m Rack Acoustic Doors
- (#6249) -2.0m Rack Acoustic Doors
- (#6263) -1.8m Rack Trim Kit
- (#6272) -2.0m Rack Trim Kit
- (#6580) -Optional Rack Security Kit
- (#7118) -Environmental Monitoring Probe
- (#7131) -IBM Rack-mount Drawer Bezel and Hardware
- (#7132) -OEM Rack-mount Drawer Bezel and Hardware
- (#7145) -IBM/OEM Rack-mount Drawer Rail Kit
- (#7311) -Dual I/O Unit Enclosure
- (#7314) -I/O Drawer Mounting Enclosure
- (#7780) -2.0m Rack Side Attach Kit
- (#7840) -Side-by-Side for 1.8m Racks
- (#7841) -Ruggedize Rack Kit
- (#EC01) -Rack Front Door (Black)
- (#EC02) -Rack Rear Door
- (#EC03) -Rack Side Cover
- (#EC04) -Rack Suite Attachment Kit
- (#EC07) -Slim Rear Acoustic Door
- (#EC08) -Slim Front Acoustic Door
- (#EC15) -Rear Door Heat Exchanger for 2.0 Meter Slim Rack
- (#EDR1) -EXP30 Ultra SSD I/O Drawer
- (#ER05) -42U Slim Rack
- Services
- (#0010) -One CSC Billing Unit
- (#0011) -Ten CSC Billing Units
- (#EUC6) -Core Use HW Feature
- (#EUC7) -Core Use HW Feature 10X
- Solid State Drive
- (#0893) -#ES0B Load Source Specify
- (#0894) -#ES0D Load Source Specify
- (#1775) -177GB SFF-1 SSD w/ eMLC (AIX/Linux)
- (#1787) -177GB SFF-1 SSD w/ eMLC (IBM i)
- (#1793) -177GB SFF-2 SSD w/ eMLC (AIX/Linux)
- (#1794) -177GB SFF-2 SSD w/ eMLC (IBM i)
- (#1887) -Quantity 150 of #1793
- (#1958) -Quantity 150 of #1794
- (#1995) -177GB SSD Module with eMLC (AIX/Linux)
- (#1996) -177GB SSD Module with eMLC (IBM i)
- (#3586) -69GB 3.5" SAS Solid State Drive
- (#3587) -69GB 3.5" SAS Solid State Drive
- (#7535) -Quantity 150 of #3586
- (#7536) -Quantity 150 of #3587
- (#EH10) -387GB SFF-2 SSD converted for AIX/Linux
- (#EH11) -387GB SFF-2 SSD converted for AIX/Linux
- (#EH12) -387GB SFF-2 SSD converted for IBM i
- (#EH13) -387GB SFF-2 SSD converted for IBM i
- (#EH14) -GEN2-S Conversion Carrier for Feature ES0C 387GB SSD
- (#EH16) -GEN2-S Conversion Carrier for Feature ES0D 387GB SSD (IBM i)
- (#ELT9) -#ES79 Load Source Specify (387GB SFF-2 SSD 5xx for IBM i)
- (#ELTF) -#ES7F Load Source Specify (775GB SFF-2 SSD 5xx for IBM i)
- (#ELSF) -#ES0F Load Source Specify (775GB SSD SFF-1)
- (#ELSH) -#ES0H Load Source Specify (775GB SSD SFF-2)
- (#ELSK) -#ES0K Load Source Specify (387GB 1.8" SSD for IBM i)
- (#EQ0C) -Quantity of 150 #ES0C
- (#EQ0D) -Quantity of 150 #ES0D
- (#EQ0G) -Quantity 150 of #ES0G (775GB SSD SFF-2)
- (#EQ0H) -Quantity 150 of #ES0H (775GB SSD SFF-2)
- (#ES0J) -387GB 1.8" SSD for AIX/Linux
- (#ES0K) -387GB 1.8" SSD for IBM i
- (#EQ19) -Quantity 150 of #ES19 (387GB SSD SFF-2)
- (#EQ1A) -Quantity 150 of #ES1A (387GB SSD SFF-2)
- (#EQ78) -Quantity 150 of #ES78 387GB SFF-2 SSD 5xx
- (#EQ79) -Quantity 150 of #ES79 387GB SFF-2 SSD 5xx
- (#EQ7E) -Quantity 150 of #ES7E 775GB SFF-2 SSD 5xx
- (#EQ7F) -Quantity 150 of #ES7F 775GB SFF-2 SSD 5xx
- (#ES02) -387GB 1.8" SAS SSD for AIX/Linux with eMLC
- (#ES04) -387GB 1.8" SAS SSD for IBM i with eMLC
- (#ES0A) -387GB SFF-1 SSD for AIX/Linux with eMLC
- (#ES0B) -387GB SFF-1 SSD for IBM i with eMLC
- (#ES0C) -387GB SFF-2 SSD for AIX/Linux with eMLC
- (#ES0D) -387GB SFF-2 SSD for IBM i with eMLC
- (#ES09) -IBM Flash Adapter 90 (PCIe2 0.9TB)
- (#ES0E) -775GB SFF-1 SSD for AIX/Linux
- (#ES0F) -775GB SFF-1 SSD for IBM i
- (#ES0G) -775GB SFF-2 SSD for AIX/Linux
- (#ES0H) -775GB SFF-2 SSD for IBM i
- (#ES10) -387GB SFF-1 SSD for AIX/Linux
- (#ES11) -387GB SFF-1 SSD for IBM i
- (#ES19) -387GB SFF-2 SSD for AIX/Linux
- (#ES1A) -387GB SFF-2 SSD for IBM i
- (#ES78) -387GB SFF-2 SSD 5xx eMLC4 for AIX/Linux
- (#ES79) -387GB SFF-2 SSD 5xx eMLC4 for IBM i
- (#ES7E) -775GB SFF-2 SSD 5xx eMLC4 for AIX/Linux
- (#ES7F) -775GB SFF-2 SSD 5xx eMLC4 for IBM i
- Specify Codes
- (#0040) -Mirrored System Disk Level, Specify Code
- (#0041) -Device Parity Protection-All, Specify Code
- (#0043) -Mirrored System Bus Level, Specify Code
- (#0047) -Device Parity RAID-6 All, Specify Code
- (#0265) -AIX Partition Specify
- (#0266) -Linux Partition Specify
- (#0267) -IBM i Operating System Partition Specify
- (#0296) -Specify Custom Data Protection
- (#0308) -Mirrored Level System Specify Code
- (#0347) -RAID Hot Spare Specify
- (#0566) -IBM i 6.1 with 6.1.1 Machine Code Specify Code
- (#0567) -IBM i 7.1 Specify Code
- (#0722) -#1787 Load Source Specify
- (#0724) -#1996 Load Source Specify
- (#0726) -Specify Load Source in #5802/#5803/#5877
- (#0727) -Specify #5886 Load Source placement
- (#0728) -Specify #5887 Load Source placement
- (#0729) -Specify EXP30 Load Source placement
- (#0837) -SAN Load Source Specify
- (#0838) -#3676 Load Source Specify
- (#0839) -#3677 Load Source Specify
- (#0840) -#3678 Load Source Specify
- (#0844) -#3658 Load Source Specify
- (#0851) -#1884 Load Source Specify
- (#0853) -#1888 Load Source Specify
- (#0855) -#3587 Load Source Specify
- (#0856) -#1911 Load Source Specify
- (#0857) -#1916 Load Source Specify
- (#0870) -#1879 Load Source Specify
- (#0871) -#1947 Load Source Specify
- (#0872) -#1948 Load Source Specify
- (#0874) -#1956 Load Source Specify
- (#0875) -#1962 Load Source Specify
- (#0876) -#1794 Load Source Specify
- (#0879) -#1737 Load Source Specify (856GB SFF-1 disk)
- (#0880) -#1738 Load Source Specify (856GB SFF-2 disk)
- (#0882) -#ES04 Load Source Specify
- (#0907) -#ESD0 Load Source Specify (1.1TB 10k SFF-1)
- (#0911) -#ESD2 Load Souce Specify (1.1TB 10k SFF-2)
- (#5550) -Sys Console On HMC
- (#EB72) -IBM i 7.2 Indicator
- (#EB73) -IBM i 7.3 Indicator
- Virtualization Engine
- (#5225) -PowerVM Express Edition
- (#5227) -PowerVM Standard Edition
- (#5228) -PowerVM Enterprise Edition
- (#EB34) -IBM i 6.1.1 Native I/O Enablement
- (#ELPM) -Trial PowerVM Live Partition Mobility
Feature availability matrix
The following feature availability matrix for MT 8205 uses the letter "A" to indicate features that are available and orderable on the specified models. "S" indicates a feature that is supported on the new model during a model conversion; these features will work on the new model, but additional quantities of these features cannot be ordered on the new model; they can only be removed. "N" indicates that the feature is not supported on the new model and must be removed during the model conversion. As additional features are announced, supported, or withdrawn, this list will be updated. Contact your your Marketing Representative for additional information.
E A = AVAILABLE S = SUPPORTED
6 N = NOT SUPPORTED, MUST BE REMOVED
D
FEAT/PN DESCRIPTION
-------- - ----------------------------------------------------------
0004 A EMEA Bulk MES Indicator
0010 A One CSC Billing Unit
0011 A Ten CSC Billing Units
0040 A Mirrored System Disk Level, Specify Code
0041 A Device Parity Protection-All, Specify Code
0043 A Mirrored System Bus Level, Specify Code
0047 A Device Parity RAID-6 All, Specify Code
0098 A Special Manufacturing Operations Indicator
0205 S RISC-to-RISC Data Migration
0265 A AIX Partition Specify
0266 A Linux Partition Specify
0267 A IBM i Operating System Partition Specify
0296 A Specify Custom Data Protection
0308 A Mirrored Level System Specify Code
0347 A RAID Hot Spare Specify
0348 A V.24/EIA232 6.1m (20-Ft) PCI Cable
0349 S V.24/EIA232 15.2m (50-Ft) PCI Cable
0353 A V.35 6.1m (20-Ft) PCI Cable
0354 S V.35 15.2m (50-Ft) PCI Cable
0356 S V.36 6.1m (20-Ft) PCI Cable
0359 A X.21 6.1m (20-Ft) PCI Cable
0360 S X.21 15.2m (50-Ft) PCI Cable
0365 S V.24/EIA232 (80-Ft) PCI Cable
0368 A V.24/EIA232 20-Ft. PCI Cable with M3
0444 S CBU Specify
0456 S Customer Specified Placement
0462 A SSD Placement Indicator - CEC
0463 S SSD Placement Indicator (5802/5803)
0464 S SSD Placement Indicator - 5886
0465 S SSD Placement Indicator - 5887
0551 S 19 inch, 1.8 meter high rack
0553 S 19 inch, 2.0 meter high rack
0555 S 19 inch, 1.3 meter high rack
0566 A IBM i 6.1 with 6.1.1 Machine Code Specify Code
0567 S IBM i 7.1 Specify Code
0599 A Rack Filler Panel Kit
0710 S Balanced Warehouse Solution Indicator
0712 S Power Cloud Solution Integrated Solution Indicator for Order
Routing
0719 A Load Source Not in CEC
0722 A #1787 Load Source Specify
0724 A #1996 Load Source Specify
0726 A Specify Load Source in #5802/#5803/#5877
0727 S Specify #5886 Load Source placement
0728 A Specify #5887 Load Source placement
0729 A Specify EXP30 Load Source placement
0837 A SAN Load Source Specify
0838 S #3676 Load Source Specify
0839 A #3677 Load Source Specify
0840 A #3678 Load Source Specify
0844 A #3658 Load Source Specify
0851 S #1884 Load Source Specify
0853 A #1888 Load Source Specify
0855 S #3587 Load Source Specify
0856 A #1911 Load Source Specify
0857 A #1916 Load Source Specify
0870 A #1879 Load Source Specify
0871 A #1947 Load Source Specify
0872 A #1948 Load Source Specify
0874 A #1956 Load Source Specify
0875 A #1962 Load Source Specify
0876 A #1794 Load Source Specify
0879 S #1737 Load Source Specify (856GB SFF-1 disk)
0880 S #1738 Load Source Specify (856GB SFF-2 disk)
0882 A #ES04 Load Source Specify
0893 A #ES0B Load Source Specify
0894 A #ES0D Load Source Specify
0907 A #ESD0 Load Source Specify (1.1TB 10k SFF-1)
0911 A #ESD2 Load Souce Specify (1.1TB 10k SFF-2)
1010 A Modem Cable - Austria
1011 A Modem Cable - Belgium
1012 A Modem Cable - Africa
1014 A Modem Cable - Italy
1015 A Modem Cable - France
1016 A Modem Cable - Germany
1017 A Modem Cable - UK
1018 A Modem Cable - Iceland/Sweden
1021 A Modem Cable - Fin/Nor
1022 A Modem Cable - Netherlands
1023 A Modem Cable - Swiss
1024 A Modem Cable - Denmark
1025 A Modem Cable - US/Canada and General Use
1103 S USB Internal Docking Station for Removable Disk Drive
1104 S USB External Docking Station for Removable Disk Drive
1106 S USB 160 GB Removable Disk Drive
1107 A USB 500 GB Removable Disk Drive
1109 S IBM Ethernet Switch J48E
1111 A 3m, Blue Cat5e Cable
1112 A 10m, Blue Cat5e Cable
1113 A 25m, Blue Cat5e Cable
1114 S Smart Analytics System routing indicator
1115 A CAT5E Ethernet Cable, 3M GREEN
1116 A CAT5E Ethernet Cable, 10M GREEN
1118 A 3m, Yellow Cat5e Cable
1119 A 10m, Yellow Cat5e Cable
1121 A CAT5E Ethernet Cable, 25M YELLOW
1135 S Integrated Storage Controller
1136 S Integrated Storage Controller w/ 24 - 600GB drives
1141 A 1-meter Cable for EXP4500 Switch
1143 A 3-meter Cable for EXP4500 Switch
1148 A EX4500 10GB Optical Transceiver
1406 S 200V 16A 4.3m (14-Ft) TL Line Cord
1408 S 4.3m 200V/16A Pwr Cd Italy
1413 S 125V 4.3m (14-Ft) Line Cord
1414 S 200V 1.8m (6-Ft) Locking Line Cord
1418 S 4.3m 200V/16A Power Cord S. Africa
1419 S 4.3m 200V/16A Power Cord Israel
1420 S 4.3m 200V/16A Power Cord EU/Asia
1421 S 4.3m 200V/16A Power Cord CH/DK
1426 S 200V 4.3m (14-Ft) Locking Line Cord
1439 S 4.3m 200V/10A Power Cord EU/Asia
1440 S 4.3m 200V/10A Power Cord Denmark
1441 S 4.3m 200V/10A Power Cord S. Africa
1442 S 4.3m 200V/10A Power Cord Swiss
1443 S 4.3m 200V/10A Power Cord UK
1445 S 4.3m 200V/10A Power Cord Israel
1449 S 4.3m 200V/32A Power Cord EU 1-PH
1450 S 4.3m 200V/16A Power Cord EU 2-PH
1476 S 4.3m 200V/12A Pwr Cd UK
1477 S 4.3m 200V/16A Pwr Cd
1737 A 856GB 10k RPM SAS SFF Disk Drive (IBM i)
1738 S 856GB 10k RPM SAS SFF-2 Disk Drive (IBM i)
1751 S 900GB 10K RPM SAS SFF Disk Drive (AIX/Linux)
1752 S 900GB 10k RPM SAS SFF-2 Disk Drive (AIX/Linux)
1775 S 177GB SFF-1 SSD w/ eMLC (AIX/Linux)
1787 S 177GB SFF-1 SSD w/ eMLC (IBM i)
1790 S 600GB 10K RPM SAS SFF Disk Drive (AIX/Linux)
1793 S 177GB SFF-2 SSD w/ eMLC (AIX/Linux)
1794 S 177GB SFF-2 SSD w/ eMLC (IBM i)
1817 S Quantity 150 of #1962
1818 S Quantity 150 of #1964
1827 A System port/UPS Conversion Cable
1828 A 1.5 Meter 12X to 4X Channel Conversion Cable
1829 S 0.6 Meter 12X Cable
1830 S 1.5 Meter 12X cable
1834 S 8.0 Meter 12X Cable
1840 S 3.0 Meter 12X Cable
1841 A 3 Meter 12X to 4X Channel Conversion Cable
1844 S Quantity 150 of #1956
1854 A 10 Meter 12X to 4X Enhanced Channel Conversion Cable
1861 A 0.6 Meter 12X DDR Cable
1862 A 1.5 Meter 12X DDR Cable
1864 A 8.0 Meter 12X DDR Cable
1865 A 3.0 Meter 12X DDR Cable
1866 S Quantity 150 of #1917
1868 S Quantity 150 of #1947
1869 S Quantity 150 of #1925
1879 S 283GB 15K RPM SAS SFF Disk Drive (IBM i)
1880 S 300GB 15K RPM SAS SFF Disk Drive (AIX/Linux)
1882 S 146.8GB 10K RPM SAS SFF Disk Drive
1884 S 69.7 GB 15K RPM SAS SFF Disk Drive
1885 S 300GB 10K RPM SFF SAS Disk Drive
1886 S 146GB 15K RPM SFF SAS Disk Drive (AIX/Linux)
1887 S Quantity 150 of #1793
1888 S 139GB 15K RPM SFF SAS Disk Drive (IBM i)
1905 S 4 GB Single-Port Fibre Channel PCI-X 2.0 DDR Adapter
1910 S 4 GB Dual-Port Fibre Channel PCI-X 2.0 DDR Adapter
1911 S 283GB 10K RPM SFF SAS Disk Drive (IBM i)
1912 S PCI-X DDR Dual Channel Ultra320 SCSI Adapter
1916 S 571GB 10k RPM SAS SFF Disk Drive (IBM i)
1917 S 146GB 15k RPM SAS SFF-2 Disk Drive (AIX/Linux)
1925 S 300GB 10k RPM SAS SFF-2 Disk Drive (AIX/Linux)
1927 S Quantity 150 of #1948
1929 S Quantity 150 of #1953
1947 S 139GB 15k RPM SAS SFF-2 Disk Drive (IBM i)
1948 S 283GB 15k RPM SAS SFF-2 Disk Drive (IBM i)
1953 S 300GB 15k RPM SAS SFF-2 Disk Drive (AIX/Linux)
1954 S 4-Port 10/100/1000 Base-TX PCI-X Adapter
1956 S 283GB 10k RPM SAS SFF-2 Disk Drive (IBM i)
1958 S Quantity 150 of #1794
1962 S 571GB 10k RPM SAS SFF-2 Disk Drive (IBM i)
1964 S 600GB 10k RPM SAS SFF-2 Disk Drive (AIX/Linux)
1977 S 2 Gigabit Fibre Channel PCI-X Adapter
1978 S IBM Gigabit Ethernet-SX PCI-X Adapter
1979 S IBM 10/100/1000 Base-TX Ethernet PCI-X Adapter
1980 S POWER GXT135P Graphics Accelerator with Digital Support
1983 S IBM 2-Port 10/100/1000 Base-TX Ethernet PCI-X Adapter
1986 S 1 Gigabit iSCSI TOE PCI-X on Copper Media Adapter
1987 S 1 Gigabit iSCSI TOE PCI-X on Optical Media Adapter
1995 S 177GB SSD Module with eMLC (AIX/Linux)
1996 S 177GB SSD Module with eMLC (IBM i)
2053 S PCIe LP RAID & SSD SAS Adapter 3Gb
2054 S PCIe RAID & SSD SAS Adapter 3Gb
2055 S PCIe RAID & SSD SAS Adapter 3Gb w/ Blind Swap Cassette
2118 S Converter Cable, VHDCI to P, Mini-68 pin to 68 pin, 0.3M
2145 A Primary OS - IBM i
2146 A Primary OS - AIX
2147 A Primary OS - Linux
2319 S Factory Deconfiguration of 1-core
2456 A 2M LC-SC 50 Micron Fiber Converter Cable
2459 A 2M LC-SC 62.5 Micron Fiber Converter Cable
2728 S 4 port USB PCIe Adapter
2738 S 2-Port USB PCI Adapter
2849 S POWER GXT135P Graphics Accelerator with Digital Support
2861 S ARTIC960Hx 4-Port EIA-232 Cable
2863 S ARTIC960Hx 4-Port X.21 Cable
2864 S ARTIC960Hx 4-Port V.35 (DTE) Cable
2893 S PCIe 2-Line WAN w/Modem
2934 A 3M Asynchronous Terminal/Printer Cable EIA-232
2936 A Asynchronous Cable EIA-232/V.24 3M
2943 S 8-Port Asynchronous Adapter EIA-232/RS-422, PCI bus
2947 S IBM ARTIC960Hx 4-Port Multiprotocol PCI Adapter
2951 S Cable, V.24 / EIA-232
2952 S Cable, V.35
2953 S Cable, V.36 / EIA-499
2954 S Cable, X.21
2962 S 2-Port Multiprotocol PCI Adapter
3124 A Serial-to-Serial Port Cable for Drawer/Drawer- 3.7M
3125 A Serial-to-Serial Port Cable for Rack/Rack- 8M
3287 A 1m, (3.3-ft) IB 40G Copper Cable QSFP/QSFP
3288 A 3m, (9.8-ft.) IB 40G Copper Cable QSFP/QSFP
3289 A 5m QDR IB/E'Net Copper Cable QSFP/QSFP
3290 A 10 meter Quad Data Rate InfiniBand Optical Cable, QSFP/QSFP
3293 A 30 meter Quad Data Rate InfiniBand Optical Cable, QSFP/QSFP
3450 A SAS YO Cable 1.5m - HD 6Gb Adapter to Enclosure
3451 A SAS YO Cable 3m - HD 6Gb Adapter to Enclosure
3452 A SAS YO Cable 6m - HD 6Gb Adapter to Enclosure
3453 A SAS YO Cable 10m - HD 6Gb Adapter to Enclosure
3454 A SAS X Cable 3m - HD 6Gb 2-Adapter to Enclosure
3455 A SAS X Cable 6m - HD 6Gb 2-Adapter to Enclosure
3456 A SAS X Cable 10m - HD 6Gb 2-Adapter to Enclosure
3457 A SAS YO Cable 15m - HD 3Gb Adapter to Enclosure
3458 A SAS X Cable 15m - HD 3Gb 2-Adapter to Enclosure
3586 S 69GB 3.5" SAS Solid State Drive
3587 S 69GB 3.5" SAS Solid State Drive
3632 S Widescreen LCD Monitor
3637 S IBM T541H /L150p 15" TFT Color Monitor
3639 S IBM ThinkVision L170p Flat Panel Monitor
3640 S ThinkVision L171p Flat Panel Monitor
3641 S IBM T115 Flat Panel Monitor
3642 S ThinkVision L191p Flat Panel Monitor
3643 S IBM T120 Flat Panel Monitor
3644 S IBM T119 Flat Panel Monitor
3645 S IBM T117 Flat Panel Monitor
3646 S 73GB 15K RPM SAS Disk Drive
3647 S 146GB 15K RPM SAS Disk Drive (AIX/Linux)
3648 S 300GB 15K RPM SAS Disk Drive (AIX/Linux)
3649 S 450GB 15K RPM SAS Disk Drive (AIX/Linux)
3652 A SAS Cable (EE) Drawer to Drawer 1M
3653 A SAS Cable (EE) Drawer to Drawer 3M
3654 A SAS Cable (EE) Drawer to Drawer 6M
3656 A SAS SFF Cable
3658 S 428GB 15K RPM SAS Disk Drive (IBM i)
3661 A SAS Cable (X) Adapter to SAS Enclosure, Dual Controller/
Dual Path 3M:
3662 A SAS Cable (X) Adapter to SAS Enclosure, Dual Controller/
Dual Path 6M:
3663 A SAS Cable (X) Adapter to SAS Enclosure, Dual Controller/
Dual Path 15M:
3675 A SAS EX Cable 3m - Drawer to Drawer
3676 S 69.7GB 15k rpm SAS Disk Drive
3677 S 139.5GB 15k rpm SAS Disk Drive (IBM i)
3678 S 283.7GB 15k rpm SAS Disk Drive (IBM i)
3680 A SAS EX Cable 6m - Drawer to Drawer
3681 A 3M SAS CABLE, ADPTR TO ADPTR (AA)
3682 S 6M SAS CABLE, ADPTR TO ADPTR (AA)
3684 A SAS Cable (AE) Adapter to Enclosure, single controller/
single path 3M
3685 A SAS Cable (AE) Adapter to Enclosure, single controller/
single path 6M
3687 A SAS Cable (YI) System to SAS Enclosure, Single Controller/
Dual Path 3M
3688 A SAS Cable (AT) 0.6 Meter
3689 A SAS AT Cable 0.6m - HD 6Gb Adapter to 12X Enclosure (AT)
3691 A SAS Cable (YO) Adapter to SAS Enclosure, Single Controller/
Dual Path 1.5 M
3692 A SAS Cable (YO) Adapter to SAS Enclosure, Single Controller/
Dual Path 3 M
3693 A SAS Cable (YO) Adapter to SAS Enclosure, Single Controller/
Dual Path 6 M
3694 A SAS Cable (YO) Adapter to SAS Enclosure, Single Controller/
Dual Path 15 M
3925 A 0.3M Serial Port Converter Cable, 9-Pin to 25-Pin
3927 A Serial Port Null Modem Cable, 9-pin to 9-pin, 3.7M
3928 A Serial Port Null Modem Cable, 9-pin to 9-pin, 10M
3930 A System Serial Port Converter Cable
4242 S 1.8 M (6-ft) Extender Cable for Displays (15-pin D-shell
to 15-pin D-shell)
4256 A Extender Cable - USB Keyboards, 1.8M
4276 A VGA to DVI Connection Converter
4367 S Package 5X #2055 & 20X #1995 (AIX/Linux)
4377 S Package 5X #2055 & 20X #1996 (IBM i)
One and only one rack indicator feature is required on
all orders (#4650 to #4666).
4650 S Rack Indicator- Not Factory Integrated
4651 S Rack Indicator, Rack #1
4652 S Rack Indicator, Rack #2
4653 S Rack Indicator, Rack #3
4654 S Rack Indicator, Rack #4
4655 S Rack Indicator, Rack #5
4656 S Rack Indicator, Rack #6
4657 S Rack Indicator, Rack #7
4658 S Rack Indicator, Rack #8
4659 S Rack Indicator, Rack #9
4660 S Rack Indicator, Rack #10
4661 S Rack Indicator, Rack #11
4662 S Rack Indicator, Rack #12
4663 S Rack Indicator, Rack #13
4664 S Rack Indicator, Rack #14
4665 S Rack Indicator, Rack #15
4666 S Rack Indicator, Rack #16
4764 S PCI-X Cryptographic Coprocessor (FIPS 4)
4794 A Power Active Memory Expansion Enablement
4807 S PCIe Crypto Coprocessor No BSC 4765-001
4808 S PCIe Crypto Coprocessor Gen3 BSC 4765-001
4929 S Power 740 Solution Edition for IBM i
4970 A One Processor of 5250 Enterprise Enablement
4973 S One Processor of 5250 Enterprise Enablement for Solution
Edition
4974 A Full 5250 Enterprise Enablement
5000 S Software Preload Required
5160 S Power Dist Unit 1 Phase NEMA
5161 S Power Dist Unit 1 Phase IEC
5162 S Power Dist Unit 2 of 3 Phase
5163 S Power Dist Unit - 3 Phase
5225 S PowerVM Express Edition
5227 A PowerVM Standard Edition
5228 A PowerVM Enterprise Edition
5260 S PCIe2 LP 4-port 1GbE Adapter
5269 S PCIe LP POWER GXT145 Graphics Accelerator
5270 S PCIe LP 10Gb FCoE 2-port Adapter
5271 S PCIe LP 4-Port 10/100/1000 Base-TX Ethernet Adapter
5272 S PCIe LP 10GbE CX4 1-port Adapter
5273 S PCIe LP 8Gb 2-Port Fibre Channel Adapter
5274 S PCIe LP 2-Port 1GbE SX Adapter
5275 S PCIe LP 10GbE SR 1-port Adapter
5276 S PCIe LP 4Gb 2-Port Fibre Channel Adapter
5277 S PCIe LP 4-Port Async EIA-232 Adapter
5278 S PCIe LP 2-x4-port SAS Adapter 3Gb
5279 S PCIe2 LP 4-Port 10GbE&1GbE SFP+ Copper&RJ45
5280 S PCIe2 LP 4-Port 10GbE&1GbE SR&RJ45 Adapter
5281 S PCIe LP 2-Port 1GbE TX Adapter
5283 S PCIe2 LP 2-Port 4X IB QDR Adapter 40Gb
5284 S PCIe2 LP 2-port 10GbE SR Adapter
5285 S PCIe2 2-Port 4X IB QDR Adapter 40Gb
5286 S PCIe2 LP 2-Port 10GbE SFP+ Copper Adapter
5287 S PCIe2 2-port 10GbE SR Adapter
5288 S PCIe2 2-Port 10GbE SFP+Copper Adapter
5289 S 2 Port Async EIA-232 PCIe Adapter
5290 S PCIe LP 2-Port Async EIA-232 Adapter
5532 S System AC Power Supply, 1925 W
5550 A Sys Console On HMC
5557 S System Console-Ethernet No IOP
5618 A Storage Backplane -- 6 SFF Bays/ SATA DVD/HH Tape
5619 S 80/160GB DAT160 SAS Tape Drive
5638 A 1.5TB/3.0TB LTO-5 SAS Tape Drive
5685 S PCIe Riser Card (Gen2)
5689 S DAT160 Data Cartridge
5700 S IBM Gigabit Ethernet-SX PCI-X Adapter
5701 S IBM 10/100/1000 Base-TX Ethernet PCI-X Adapter
5706 S IBM 2-Port 10/100/1000 Base-TX Ethernet PCI-X Adapter
5708 S 10Gb FCoE PCIe Dual Port Adapter
5713 S 1 Gigabit iSCSI TOE PCI-X on Copper Media Adapter
5714 S 1 Gigabit iSCSI TOE PCI-X on Optical Media Adapter
5716 S 2 Gigabit Fibre Channel PCI-X Adapter
5717 S 4-Port 10/100/1000 Base-TX PCI Express Adapter
5721 S 10 Gb Ethernet-SR PCI-X 2.0 DDR Adapter
5722 S 10 Gb Ethernet-LR PCI-X 2.0 DDR Adapter
5723 S 2-Port Asynchronous EIA-232 PCI Adapter
5729 S PCIe2 8Gb 4-port Fibre Channel Adapter
5732 S 10 Gigabit Ethernet-CX4 PCI Express Adapter
5735 S 8 Gigabit PCI Express Dual Port Fibre Channel Adapter
5736 S PCI-X DDR Dual Channel Ultra320 SCSI Adapter
5740 S 4-Port 10/100/1000 Base-TX PCI-X Adapter
5744 S PCIe2 4-Port 10GbE&1GbE SR&RJ45 Adapter
5745 S PCIe2 4-Port 10GbE&1GbE SFP+Copper&RJ45 Adapter
5746 S Half High 800GB/1.6TB LTO4 SAS Tape Drive
5747 A IBM LTO Ultrium 4 800 GB Data Cartridge
5748 S POWER GXT145 PCI Express Graphics Accelerator
5749 S 4Gbps Fibre Channel (2-Port)
5758 S 4 GB Single-Port Fibre Channel PCI-X 2.0 DDR Adapter
5759 S 4 Gb Dual-Port Fibre Channel PCI-X 2.0 DDR Adapter
5762 S SATA Slimline DVD-RAM Drive
5767 S 2-Port 10/100/1000 Base-TX Ethernet PCI Express Adapter
5768 S 2-Port Gigabit Ethernet-SX PCI Express Adapter
5769 S 10 Gigabit Ethernet-SR PCI Express Adapter
5771 A SATA Slimline DVD-RAM Drive
5772 S 10 Gigabit Ethernet-LR PCI Express Adapter
5773 S 4 Gigabit PCI Express Single Port Fibre Channel Adapter
5774 S 4 Gigabit PCI Express Dual Port Fibre Channel Adapter
5785 S 4 Port Async EIA-232 PCIe Adapter
5796 S PCI-DDR 12X Expansion Drawer
5802 S 12X I/O Drawer PCIe, SFF disk
5805 S PCIe 380MB Cache Dual - x4 3Gb SAS RAID Adapter
5877 S 12X I/O Drawer PCIe, No Disk
5886 S EXP 12S Expansion Drawer
5887 S EXP24S SFF Gen2-bay Drawer
5899 S PCIe2 4-port 1GbE Adapter
5900 S PCI-X DDR Dual -x4 SAS Adapter
5901 S PCIe Dual-x4 SAS Adapter
5902 S PCI-X DDR Dual - x4 3Gb SAS RAID Adapter
5908 S PCI-X DDR 1.5GB Cache SAS RAID Adapter (BSC)
5912 S PCI-X DDR Dual - x4 SAS Adapter
5913 S PCIe2 1.8GB Cache RAID SAS Adapter Tri-port 6Gb
5915 A SAS AA Cable 3m - HD 6Gb Adapter to Adapter
5916 A SAS AA Cable 6m - HD 6Gb Adapter to Adapter
5917 A SAS AA Cable 1.5m - HD 6Gb Adapter to Adapter
5918 A SAS AA Cable 0.6m - HD 6Gb Adapter to Adapter
5922 S Non-paired SAS RAID indicator
5923 A Non-paired PCIe SAS RAID Indicator
5924 A Non-paired Indicator 5913 PCIe SAS RAID Adapter
5925 A Shared EXP30 Indicator
5926 A SAS EX Cable 1.5m - Drawer to Drawer
5927 A Remote EXP30 Indicator
5951 S Full Width Keyboard -- USB, US English, #103P
5952 S Full Width Keyboard -- USB, French, #189
5953 S Full Width Keyboard -- USB, Italian, #142
5954 S Full Width Keyboard -- USB, German/Austrian, #129
5955 S Full Width Keyboard -- USB, UK English, #166P
5956 S Full Width Keyboard -- USB, Spanish, #172
5957 S Full Width Keyboard -- USB, Japanese, #194
5958 S Full Width Keyboard -- USB, Brazilian Portuguese, #275
5959 S Full Width Keyboard -- USB, Hungarian, #208
5960 S Full Width Keyboard -- USB, Korean, #413
5961 S Full Width Keyboard -- USB, Chinese, #467
5962 S Full Width Keyboard -- USB, French Canadian, #445
5964 S Full Width Keyboard -- USB, Belgian/UK, #120
5965 S Full Width Keyboard -- USB, Swedish/Finnish, #153
5966 S Full Width Keyboard -- USB, Danish, #159
5967 S Full Width Keyboard -- USB, Bulgarian, #442
5968 S Full Width Keyboard -- USB, Swiss/French/German, #150
5969 S Full Width Keyboard -- USB, Norwegian,#155
5970 S Full Width Keyboard -- USB, Dutch, #143
5971 S Full Width Keyboard -- USB, Portuguese, #163
5972 S Full Width Keyboard -- USB, Greek, #319
5973 S Full Width Keyboard -- USB, Hebrew, #212
5974 S Full Width Keyboard -- USB, Polish, #214
5975 S Full Width Keyboard -- USB, Slovakian, #245
5976 S Full Width Keyboard -- USB, Czech, #243
5977 S Full Width Keyboard -- USB, Turkish, #179
5978 S Full Width Keyboard -- USB, LA Spanish, #171
5979 S Full Width Keyboard -- USB, Arabic, #253
5980 S Full Width Keyboard -- USB, Thai, #191
5981 S Full Width Keyboard -- USB, Russian, #443
5982 S Full Width Keyboard -- USB, Slovenian, #234
5983 S Full Width Keyboard -- USB, US English Euro, #103P
6001 S Power Control Cable (SPCN) - 2 meter
6006 A Power Control Cable (SPCN) - 3 meter
6007 A Power Control Cable (SPCN) - 15 meter
6008 S Power Control Cable (SPCN) - 6 meter
6029 S Power Control Cable (SPCN) - 30 meter
6068 A Opt Front Door for 1.8m Rack
6069 A Opt Front Door for 2.0m Rack
6248 A 1.8m Rack Acoustic Doors
6249 A 2.0m Rack Acoustic Doors
6260 S Redundant or Base Power Supply for 7031 Model D24/T24 I/O
Enclosure
6261 S Power Supply for 7031 Model D24/T24 I/O Enclosure
6263 A 1.8m Rack Trim Kit
6272 A 2.0m Rack Trim Kit
6446 S Dual-port 12X Channel Interface Attach - Short Run
6457 S Dual-port 12X Channel Interface Attach- Long Run
6458 A Power Cord 4.3m (14-ft), Drawer to Wall/IBM PDU (250V/10A)
6460 A Power Cord 4.3m (14-ft), Drawer To OEM PDU (125V, 15A)
6469 A Power Cord 4.3m (14-ft), Drawer to Wall/OEM PDU (250V/15A)
U. S.
6470 A Power Cord 1.8m (6-ft), Drawer to Wall (125V/15A)
6471 A Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU (125V/15A)
6472 A Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU (250V/16A)
6473 A Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU (250V/10A)
6474 A Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/13A)
6475 A Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/16A)
6476 A Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/10A)
6477 A Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/16A)
6478 A Power Cord 2.7 M(9-foot), To Wall/OEM PDU, (250V, 16A)
6479 S Power Cord (9-foot), To Wall/OEM PDU, (250V, 10A)
6488 A Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (125V/15A
or 250V/10A )
6489 A 4.3m (14-Ft) 3PH/24A 380-415V Power Cord
6491 A 4.3m (14-Ft) 1PH/48A 200-240V Power Cord
6492 A 4.3m (14-Ft) 1PH/48-60A 200-240V Power Cord
6493 A Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/10A)
6494 A Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/10A)
6495 S Power Cord (9-foot), To Wall/OEM PDU, (250V, 10A)
6496 A Power Cord 2.7M (9-foot), To Wall/OEM PDU, (250V, 10A)
6497 S Power Cord (6-foot), To Wall/OEM PDU, (250V, 10A)
6498 S Power Cord (6-foot), To Wall/OEM PDU, (250V, 15A)
6577 A Power Cable - Drawer to IBM PDU, 200-240V/10A
6580 A Optional Rack Security Kit
6586 S Modem Tray for 19-Inch Rack
6651 A Power Cord 2.7M (9-foot), To Wall/OEM PDU, (125V, 15A)
6653 A 4.3m (14-Ft) 3PH/16A 380-415V Power Cord
6654 A 4.3m (14-Ft) 1PH/24-30A Pwr Cord
6655 A 4.3m (14-Ft) 1PH/24-30A WR Pwr Cord
6656 A 4.3m (14-Ft)1PH/24A Power Cord
6657 A 4.3m (14-Ft) 1PH/24A Power Cord
6659 A Power Cord 2.7M (9-foot), To Wall/OEM PDU, (250V, 15A)
6660 A Power Cord 4.3m (14-ft), Drawer to Wall/OEM PDU (125V/15A)
6665 A Power Cord 2.8m (9.2-ft), Drawer to Wall/IBM PDU, (250V/
10A)
6669 A Power Cord 4.3M (14-foot), Drawer to OEM PDU, (250V, 15A)
6670 S Power Cord (6-foot), To Wall (125V, 15A), PT #59
6671 A Power Cord 2.7M (9-foot), Drawer to IBM PDU, 250V/10A
6672 A Power Cord 2M (6.5-foot), Drawer to IBM PDU, 250V/10A
6680 A Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/10A)
6687 S Power Cord (6-foot), To Wall, (250V, 15A)
6771 A Two 1M Intra-rack Fibre Channel Cables
6773 A Two 3M Intra-rack Fibre Channel Cables
6805 S PCI 2-Line WAN IOA No IOP
6808 S PCI 4-Modem WAN IOA No IOP
6833 S PCI 2-Line WAN w/Modem NoIOP
7109 A Intelligent PDU+, 1 EIA Unit, Universal UTG0247 Connector
7118 A Environmental Monitoring Probe
7131 S IBM Rack-mount Drawer Bezel and Hardware
7132 S OEM Rack-mount Drawer Bezel and Hardware
7145 S IBM/OEM Rack-mount Drawer Rail Kit
7188 A Power Distribution Unit
7311 S Dual I/O Unit Enclosure
7314 S I/O Drawer Mounting Enclosure
7517 S Quantity 150 of #3676
7518 S Quantity 150 of #3677
7519 S Quantity 150 of #3678
7535 S Quantity 150 of #3586
7536 S Quantity 150 of #3587
7538 S Quantity 150 of #3658
7549 S Quantity 150 of #3647
7564 S Quantity 150 of #3648
7565 S Quantity 150 of #3649
7780 S 2.0m Rack Side Attach Kit
7801 S Ethernet Cable, 6M, Hardware Management Console to System
Unit
7802 A Ethernet Cable, 15m, Hardware Management Console to System
Unit
7840 S Side-by-Side for 1.8m Racks
7841 S Ruggedize Rack Kit
8143 S Linux Software Preinstall
8144 S Linux Software Preinstall (Business Partners)
8841 S Mouse - USB, with Keyboard Attachment Cable
8845 S USB Mouse
9169 S Order Routing Indicator- System Plant
9300 S Language Group Specify - US English
9359 A specify mode-1 1(1)5901/5278 for EXP24S #5887
9360 A Specify mode-1 1(2)5901/5278 for EXP24S #5887
9361 A Specify mode-2 1(2)5901/5278 for EXP24S #5887
9365 A Specify mode-4 1(4)5901/5278 for EXP24S #5887
9366 A Specify mode-2 1(4)5901/5278 for EXP24S #5887
9367 A Specify mode-1 1(2)5903/5805 for EXP24S #5887
9368 A Specify mode-2 1(4)5903/5805 for EXP24S #5887
9382 A Specify mode-1 1(1)5904/6/8 for EXP24S #5887
9383 A Specify mode-1 1(2) 5904/6/8 for EXP24S #5887
9384 A Specify mode-1 & CEC SAS port for EXP24 #5887
9385 A Specify mode-1 1(2) 5913 for EXP24S #5887
9386 A Specify mode-2 1(4) 5913 for EXP24S #5887
9388 A Specify Mode-1 & EXP30 for 1 EXP24S #5887
9440 S New AIX License Core Counter
9441 S New IBM i License Core Counter
9442 S New Red Hat License Core Counter
9443 S New SUSE License Core Counter
9444 S Other AIX License Core Counter
9445 S Other Linux License Core Counter
9446 S 3rd Party Linux License Core Counter
9447 S VIOS Core Counter
9449 S Other License Core Counter
9461 S Month Indicator
9462 S Day Indicator
9463 S Hour Indicator
9464 S Minute Indicator
9465 S Qty Indicator
9466 S Countable Member Indicator
9700 S Language Group Specify - Dutch
9703 S Language Group Specify - French
9704 S Language Group Specify - German
9705 S Language Group Specify - Polish
9706 S Language Group Specify - Norwegian
9707 S Language Group Specify - Portuguese
9708 S Language Group Specify - Spanish
9711 S Language Group Specify - Italian
9712 S Language Group Specify - Canadian French
9714 S Language Group Specify - Japanese
9715 S Language Group Specify - Traditional Chinese (Taiwan)
9716 S Language Group Specify - Korean
9718 S Language Group Specify - Turkish
9719 S Language Group Specify - Hungarian
9720 S Language Group Specify - Slovakian
9721 S Language Group Specify - Russian
9722 S Language Group Specify - Simplified Chinese (PRC)
9724 S Language Group Specify - Czech
9725 S Language Group Specify -- Romanian
9726 S Language Group Specify - Croatian
9727 S Language Group Specify -- Slovenian
9728 S Language Group Specify - Brazilian Portuguese
9729 S Language Group Specify - Thai
B0LG S ServicePac Not Selected
B0LH S Service Renewal Requested
B0UQ A SP WSU 3Y 24x7 SD
B0VH A SP HDR/MR POWER 3Y
EB2W A EXP30 Carrier for 1.8-inch SSD
EB34 A IBM i 6.1.1 Native I/O Enablement
EB72 A IBM i 7.2 Indicator
EB73 A IBM i 7.3 Indicator
EC01 A Rack Front Door (Black)
EC02 A Rack Rear Door
EC03 A Rack Side Cover
EC04 A Rack Suite Attachment Kit
EC07 A Slim Rear Acoustic Door
EC08 A Slim Front Acoustic Door
EC15 S Rear Door Heat Exchanger for 2.0 Meter Slim Rack
EC27 S PCIe2 LP 2-Port 10GbE RoCE SFP+ Adapter
EC28 S PCIe2 2-Port 10GbE RoCE SFP+ Adapter
EC29 S PCIe2 LP 2-Port 10GbE RoCE SR Adapter
EC2M S PCIe3 LP 2-port 10GbE NIC&RoCE SR Adapter
EC2N S PCIe3 2-port 10GbE NIC&RoCE SR Adapter
EC42 A PCIe2 3D Graphics Adapter x1
EC2G S PCIe2 LP 2-port 10GbE SFN6122F Adapter
EC2H A PCIe2 LP 2-port 10GbE SFN5162F Adapter
EC2J S PCIe2 2-port 10GbE SFN6122F Adapter
EC2K A PCIe2 2-port 10GbE SFN5162F Adapter
EC30 S PCIe2 2-Port 10GbE RoCE SR Adapter
EC37 S PCIe3 LP 2-port 10GbE NIC&RoCE SFP+ Copper Adapter
EC38 S PCIe3 2-port 10GbE NIC&RoCE SFP+ Copper Adapter
EC41 S PCIe2 LP 3D Graphics Adapter x1
ECB0 A 0.6m (2.0-ft), Blue CAT5 Ethernet Cable
ECB2 A 1.5m (4.9-ft), Blue CAT5 Ethernet Cable
ECBB A SAS AT Cable 0.6m - HD Narrow 6Gb Adapter to 12X
Enclosure (AT)
ECBJ A SAS X Cable 3m - HD Narrow 6Gb 2-Adapters to Enclosure
ECBK A SAS X Cable 6m - HD Narrow 6Gb 2-Adapters to Enclosure
ECBL A SAS X Cable 10m - HD Narrow 6Gb 2-Adapters to Enclosure
ECBM A SAS X Cable 15m - HD Narrow 3Gb 2-Adapters to Enclosure
ECBT A SAS YO Cable 1.5m - HD Narrow 6Gb Adapter to Enclosure
ECBU A SAS YO Cable 3m - HD Narrow 6Gb Adapter to Enclosure
ECBV A SAS YO Cable 6m - HD Narrow 6Gb Adapter to Enclosure
ECBW A SAS YO Cable 10m - HD Narrow 6Gb Adapter to Enclosure
ECBX A SAS YO Cable 15m - HD Narrow 3Gb Adapter to Enclosure
ECBY A SAS AE1 Cable 4m - HD Narrow 6Gb Adapter to Enclosure
ECBZ A SAS YE1 Cable 3m - HD Narrow 6Gb Adapter to Enclosure
ECC0 A SAS AA Cable 0.6m - HD Narrow 6Gb Adapter to Adapter
ECC2 A SAS AA Cable 1.5m - HD Narrow 6Gb Adapter to Adapter
ECC3 A SAS AA Cable 3m - HD Narrow 6Gb Adapter to Adapter
ECC4 A SAS AA Cable 6m - HD Narrow 6Gb Adapter to Adapter
ECSC A Custom Service Specify, Shenzhen, China
ECSM A Custom Service Specify, Mexico
ECSP A Custom Service Specify, Poughkeepsie, USA
ECSS S Integrated Solution Packing
ECW0 A Optical Wrap Plug
EDR1 S EXP30 Ultra SSD I/O Drawer
EH10 S 387GB SFF-2 SSD converted for AIX/Linux
EH11 S 387GB SFF-2 SSD converted for AIX/Linux
EH12 S 387GB SFF-2 SSD converted for IBM i
EH13 S 387GB SFF-2 SSD converted for IBM i
EH14 S GEN2-S Conversion Carrier for Feature ES0C 387GB SSD
EH16 S GEN2-S Conversion Carrier for Feature ES0D 387GB SSD
(IBM i)
EHK1 S DSW Order Specify Code
EHK2 S Solution Specify Code
EHSS S SPSS on Power Solution Indicator
EJ01 A Storage Backplane -- 8 SFF Bays/175MB RAID/Dual IOA
EJ02 A Split Drive Bay Capability for #5618
EJ03 S GX++ 2-port PCIe2 x8 Adapter
EJ04 S GX++ Dual-port 12x Channel Attach
EJ10 S PCIe3 SAS Tape/DVD Adapter Quad-port 6Gb x8
EJ11 S PCIe3 LP SAS Tape/DVD Adapter Quad-port 6Gb x8
EJ27 S PCIe Crypto Coprocessor No BSC 4765-001
EJ28 S PCIe Crypto Coprocessor Gen3 BSC 4765-001
EJ0J S PCIe3 RAID SAS Adapter Quad-port 6Gb x8
EJ0L S PCIe3 12GB Cache RAID SAS Adapter Quad-port 6Gb x8
EJ0M S PCIe3 LP RAID SAS ADAPTER Quad-Port 6Gb x8
EJP1 A Specify Mode-1 1(1)ESA1/ESA2 for EXP24S #5887
EJP2 A Specify Mode-1 1(2)ESA1/ESA2 for EXP24S #5887
EJP3 A Specify Mode-2 1(2)ESA1/ESA2 1(2) X for EXP24S #5887 or
#EL1S
EJP4 A Specify Mode-2 1(4)ESA1/ESA2 for EXP24S #5887
EJP5 A Specify Mode-4 1(4)ESA1/ESA2 for EXP24S #5887
EJP6 A Specify Mode-2 1(1)ESA1/ESA2 1(2) YO for EXP24S #5887 or
#EL1S
EJP7 A Specify Mode-2 (2 )ESA1/ESA2 1(2) YO for EXP24 #5887 or
#EL1S
EJPA A Specify mode-2 (1) ESA1/ESA2 1(1) YO for EXP24 #5887 or
#EL1S
EJPB A Specify mode-2 (2)ESA1/ESA2 1(1) X for EXP24#5887 or #EL1S
EJPC A Specify mode-4 (1)ESA1/ESA2 for EXP24 #5887
EJPD A Specify mode-4 (2)ESA1/ESA2 for EXP24 #5887
EJPE A Specify mode-4 (3)ESA1/ESA2 for EXP24 #5887
EJPJ A Specify mode-2 (1)5901/5278 for EXP24 #5887
EJPK A Specify mode-2 (2)5901/5278 for EXP24 #5887
EJPL A Specify mode-4 (1)5901/5278 for EXP24 #5887
EJPM A Specify mode-4 (2)5901/5278 for EXP24 #5887
EJPN A Specify mode-4 (3)5901/5278 for EXP24 #5887
EJPR A Specify mode-2 (2)5903/5805 for EXP24 #5887
EJPT A Specify mode-2 (2)5913 for EXP24 #5887
EJPY A Specify Left Half 12X I/O Drawer to ESA1/ESA2
EJPZ A Specify Right Half 12X I/O Drawer to ESA1/ESA2
EJR1 A Specify Mode-1 1(1)EJ0J/EJ0M/EL3B for EXP24S (#5887/EL1S))
EJR2 A Specify Mode-1 1(2)EJ0J/EJ0M/EL3B for EXP24S (#5887/EL1S))
EJR3 A Specify Mode-2 1(2)EJ0J/EJ0M/EL3B 1(2) X for EXP24S
(#5887/EL1S)
EJR4 A Specify Mode-2 1(4)EJ0J/EJ0M/EL3B for EXP24S (#5887/EL1S)
EJR5 A Specify Mode-4 1(4)EJ0J/EJ0M/EL3B for EXP24S (#5887/EL1S)
EJR6 A Specify Mode-2 1(1)EJ0J/EJ0M/EL3B 1(2) YO for EXP24S
(#5887/EL1S)
EJR7 A Specify Mode-2 1(2)EJ0J/EJ0M/EL3B 1(2) YO for EXP24S
(#5887/EL1S)
EJRA A Specify Mode-2 1(1)EJ0J/EJ0M/EL3B 1(1) YO for EXP24S
(#5887/El1S)
EJRB A Specify Mode-2 1(2)EJ0J/EJ0M/EL3B 1(1) X for EXP24S
(#5887/EL1S)
EJRC A Specify Mode-4 1(1)EJ0J/EJ0M/EL3B for EXP24S (#5887/EL1S)
EJRD A Specify Mode-4 1(2)EJ0J/EJ0M/EL3B for EXP24S (#5887/EL1S)
EJRE A Specify Mode-4 1(3)EJ0J/EJ0M/EL3B for EXP24S (#5888/EL1S)
EJRP A Specify Mode-1 1(2)EJ0L for EXP24S (#5887/EL1S)
EJRR A Specify mode-2 1(4) EJ0L for EXP24S #5887/EL1S
EJRS A Specify Mode-2 1(2)EJ0L 1(2) X for EXP24S (#5887/EL1S)
EJRT A Specify Mode-2 1(2)EJ0L 1(1) X for EXP24S (#5887/EL1S)
EJRU A Non-paired Indicator EJ0L PCIe SAS RAID Adapter
EJRW A Specify Left Half 12X I/O Drawer to PCIe3 12GB RAID SAS
Adapter
EJRX A Specify Right Half 12X I/O Drawer to PCIe3 12GB RAID SAS
Adapter
EJRY A Specify Left Half 12X I/O Drawer to PCIe3 RAID SAS
Adapter
EJRZ A Specify Right Half 12X I/O Drawer to PCIe3 RAID SAS
Adapter
EJS1 A Non-paired Indicator ESA3 PCIe SAS RAID Adapter
EJS2 A Specify Mode-2 1(2)ESA3 for EXP24S (#5887/#EL1S)
EJS3 A Specify Mode-1 1(2)ESA3 for EXP24S (#5887/#EL1S)
EJS4 A Specify Mode-2 1(4)ESA3 for EXP24S (#5887/#EL1S)
EJS5 A Specify Left Half 12X I/O Drawer to PCIe2 1.8GB RAID
SAS Adapter
EJS6 A Specify Right Half 12X I/O Drawer to PCIe2 1.8GB RAID
SAS Adapter
EK51 S Full Width Keyboard -- USB, US English, #103P
EK52 S Full Width Keyboard -- USB, French, #189
EK53 S Full Width Keyboard -- USB, Italian, #142
EK54 S Full Width Keyboard -- USB, German/Austrian, #129
EK55 S Full Width Keyboard -- USB, UK English, #166P
EK56 S Full Width Keyboard -- USB, Spanish, #172
EK57 S Full Width Keyboard -- USB, Japanese, #194
EK58 S Full Width Keyboard -- USB, Brazilian Portuguese, #275
EK59 S Full Width Keyboard -- USB, Hungarian, #208
EK60 S Full Width Keyboard -- USB, Korean, #413
EK61 S Full Width Keyboard -- USB, Chinese, #467
EK62 S Full Width Keyboard -- USB, French Canadian, #445
EK64 S Full Width Keyboard -- USB, Belgian/UK, #120
EK65 S Full Width Keyboard -- USB, Swedish/Finnish, #153
EK66 S Full Width Keyboard -- USB, Danish, #159
EK67 S Full Width Keyboard -- USB, Bulgarian, #442
EK68 S Full Width Keyboard -- USB, Swiss/French/German, #150
EK69 S Full Width Keyboard -- USB, Norwegian,#155
EK70 S Full Width Keyboard -- USB, Dutch, #143
EK71 S Full Width Keyboard -- USB, Portuguese, #163
EK72 S Full Width Keyboard -- USB, Greek, #319
EK73 S Full Width Keyboard -- USB, Hebrew, #212
EK74 S Full Width Keyboard -- USB, Polish, #214
EK75 S Full Width Keyboard -- USB, Slovakian, #245
EK76 S Full Width Keyboard -- USB, Czech, #243
EK77 S Full Width Keyboard -- USB, Turkish, #179
EK78 S Full Width Keyboard -- USB, LA Spanish, #171
EK79 S Full Width Keyboard -- USB, Arabic, #253
EK80 S Full Width Keyboard -- USB, Thai, #191
EK81 S Full Width Keyboard -- USB, Russian, #443
EK82 S Full Width Keyboard -- USB, Slovenian, #234
EK83 S Full Width Keyboard -- USB, US English Euro, #103P
ELB9 S Power 740 AIX Solution Edition
ELC0 A PDU Access Cord 0.38m
ELPM A Trial PowerVM Live Partition Mobility
ELT9 S #ES79 Load Source Specify (387GB SFF-2 SSD 5xx for IBM i)
ELTF S #ES7F Load Source Specify (775GB SFF-2 SSD 5xx for IBM i)
ELS1 A #ES11 Load Source Specify (387GB SSD SFF-1)
ELS9 A #ES1A Load Source Specify (387GB SSD SFF-2)
ELSF A #ES0F Load Source Specify (775GB SSD SFF-1)
ELSH A #ES0H Load Source Specify (775GB SSD SFF-2)
ELSJ A #ESDJ Load Source Specify (571GB 15K RPM SFF-1 )
ELSK A #ES0K Load Source Specify (387GB 1.8" SSD for IBM i)
ELSN A #ESDN Load Source Specify (571GB 15K RPM SFF-2 )
EM01 S Memory Riser Card
EM08 S 8GB (2x4GB) Memory DIMMs, 1066 MHz, 2Gb DDR3 DRAM
EM4B S 16GB (2x8GB) Memory DIMMs, 1066 MHz, 4Gb DDR3 DRAM
EM4C S 32GB (2x16GB) Memory DIMMs, 1066 MHz, 4Gb DDR3 DRAM
EM4D S 64GB (2x32GB) Memory DIMMs, 1066 MHz, 4Gb DDR3 DRAM
EN01 A 1m (3.3-ft), 10GbE'Net Cable SFP+ Act Twinax Copper
EN02 A 3m (9.8-ft), 10Gb E'Net Cable SFP+ Act Twinax Copper
EN03 A 5m (16.4-ft), 10Gb E'Net Cable SFP+ Act Twinax Copper
EN05 S PCIe x8 Cable 1.5m
EN07 S PCIe x8 Cable 3m
EN0K A PCIe2 4-port (10Gb FCoE & 1GbE) SFP+Copper&RJ45
EN0L A PCIe2 LP 4-port(10Gb FCoE & 1GbE) SFP+Copper&RJ45
EN13 S PCIe 1-port Bisync Adapter
EN27 S 2 Port Async EIA-232 PCIe Adapter
EN28 S PCIe LP 2-Port Async EIA-232 Adapter
EN29 S 2 Port Async EIA-232 PCIe Adapter
EN0A S PCIe2 16Gb 2-port Fibre Channel Adapter
EN0B S PCIe2 LP 16Gb 2-port Fibre Channel Adapter
EN0H S PCIe2 4-port (10Gb FCoE & 1GbE) SR&RJ45
EN0J S PCIe2 LP 4-port (10Gb FCoE & 1GbE) SR&RJ45
EN0S S PCIe2 4-Port (10Gb+1GbE) SR+RJ45 Adapter
EN0T S PCIe2 LP 4-Port (10Gb+1GbE) SR+RJ45 Adapter
EN0U S PCIe2 4-port (10Gb+1GbE) Copper SFP+RJ45 Adapter
EN0V S PCIe2 LP 4-port (10Gb+1GbE) Copper SFP+RJ45 Adapter
EN0W S PCIe2 2-port 10/1GbE BaseT RJ45 Adapter
EN0X S PCIe2 LP 2-port 10/1GbE BaseT RJ45 Adapter
EN0Y S PCIe2 LP 8Gb 4-port Fibre Channel Adapter
EPCP S 6-core 4.2 GHz POWER7+ Processor Module
EPCQ S 8-core 3.6 GHz POWER7+ Processor Module
EPCR S 8-core 4.2 GHz POWER7+ Processor Module
EPDP S One Processor Activation for Processor Feature #EPCP
EPDQ S One Processor Activation for Processor Feature #EPCQ
EPDR S One Processor Activation for Processor Feature #EPCR
EPEP S Zero-priced Processor Activation for #EPCP
EPEQ S Zero-priced Processor Activation for #EPCQ
EPER S Zero-priced Processor Activation for #EPCR
EQ02 A Quantity 150 of #3452 SAS YO Cable 6m - HD 6Gb Adapter to
Enclosure
EQ03 A Quantity 150 of #3453 SAS YO Cable 10m - HD 6Gb Adapter to
Enclosure
EQ0C S Quantity of 150 #ES0C
EQ0D S Quantity of 150 #ES0D
EQ0G S Quantity 150 of #ES0G (775GB SSD SFF-2)
EQ0H S Quantity 150 of #ES0H (775GB SSD SFF-2)
EQ19 S Quantity 150 of #ES19 (387GB SSD SFF-2)
EQ1A S Quantity 150 of #ES1A (387GB SSD SFF-2)
EQ38 S Quantity 150 of #1738 (856GB SFF-2 disk)
EQ52 S Quantity 150 of #1752 (900GB SFF-2 disk)
EQ78 S Quantity 150 of #ES78 387GB SFF-2 SSD 5xx
EQ79 S Quantity 150 of #ES79 387GB SFF-2 SSD 5xx
EQ7E S Quantity 150 of #ES7E 775GB SFF-2 SSD 5xx
EQ7F S Quantity 150 of #ES7F 775GB SFF-2 SSD 5xx
EQD2 S Quantity 150 of #ESD2 (1.1TB 10k SFF-2)
EQD3 S Quantity 150 of #ESD3 (1.2TB 10k SFF-2)
EQDN S Quantity 150 of #ESDN (571GB 15K RPM SAS SFF-2 for IBM
i)
EQDP S Quantity 150 of #ESDP (600GB 15K RPM SAS SFF-2 for AIX/
LINUX)
ER05 S 42U Slim Rack
ERF1 S RFID Tags for Servers, Compute Nodes, Chassis, Racks, and
HMCs
ES02 S 387GB 1.8" SAS SSD for AIX/Linux with eMLC
ES04 S 387GB 1.8" SAS SSD for IBM i with eMLC
ES0A S 387GB SFF-1 SSD for AIX/Linux with eMLC
ES0B S 387GB SFF-1 SSD for IBM i with eMLC
ES0C S 387GB SFF-2 SSD for AIX/Linux with eMLC
ES0D S 387GB SFF-2 SSD for IBM i with eMLC
ES09 S IBM Flash Adapter 90 (PCIe2 0.9TB)
ES0E S 775GB SFF-1 SSD for AIX/Linux
ES0F S 775GB SFF-1 SSD for IBM i
ES0G S 775GB SFF-2 SSD for AIX/Linux
ES0H S 775GB SFF-2 SSD for IBM i
ES0J S 387GB 1.8" SSD for AIX/Linux
ES0K S 387GB 1.8" SSD for IBM i
ES10 S 387GB SFF-1 SSD for AIX/Linux
ES11 S 387GB SFF-1 SSD for IBM i
ES19 S 387GB SFF-2 SSD for AIX/Linux
ES1A S 387GB SFF-2 SSD for IBM i
ES78 S 387GB SFF-2 SSD 5xx eMLC4 for AIX/Linux
ES79 S 387GB SFF-2 SSD 5xx eMLC4 for IBM i
ES7E S 775GB SFF-2 SSD 5xx eMLC4 for AIX/Linux
ES7F S 775GB SFF-2 SSD 5xx eMLC4 for IBM i
ESA1 S PCIe2 RAID SAS Adapter Dual-port 6Gb
ESA2 S PCIe2 LP RAID SAS Adapter Dual-port 6Gb
ESA3 S PCIe2 1.8GB Cache RAID SAS Adapter Tri-port 6Gb CR
ESC0 S S&H - No Charge
ESC6 S S&H-b
ESD0 S 1.1TB 10K RPM SAS SFF-1 Disk Drive (IBM i)
ESD1 S 1.2TB 10K RPM SAS SFF-1 Disk Drive (AIX/Linux)
ESD2 S 1.1TB 10K RPM SAS SFF-2 Disk Drive (IBMi)
ESD3 S 1.2TB 10K RPM SAS SFF-2 Disk Drive (AIX/Linux)
ESDJ S 571GB 15K RPM SAS SFF-1 Disk Drive - 528 Block (IBM i)
ESDK S 600GB 15K RPM SAS SFF-1 Disk Drive - 5xx Block (AIX/Linux)
ESDN S 571GB 15K RPM SAS SFF-2 Disk Drive - 528 Block
ESDP S 600GB 15K RPM SAS SFF-2 Disk Drive - 5xx Block
ESR2 S Six ES02 387GB 1.8" SAS SSD for AIX/Linux with eMLC
ESR4 S Six ES04 387GB 1.8" SAS SSD for IBM i with eMLC
ESRA A Four ES0A 387GB SFF-1 SSD for AIX/Linux with eMLC
ESRB A Four ES0B 387GB SFF-1 SSD for IBM i with eMLC
ESRC A Four ES0C 387GB SFF-2 SSD for AIX/Linux with eMLC
ESRD A Four ES0D 387GB SFF-2 SSD for IBM i with eMLC
ESRE S Four ES10 387GB SFF-1 SSD for AIX/Linux
ESRF S Four ES11 387GB SFF-1 SSD for IBM i
ESRG S Four ES19 387GB SFF-2 SSD for AIX/Linux
ESRH S Four ES1A 387GB SFF-2 SSD for IBM i
ESRJ S Six ES0J 387GB 1.8" SSD for AIX/Linux
ESRK S Six ES0K 387GB 1.8" SSD for IBM i
EU01 A 1TB Removable Disk Drive Cartridge
EU03 A RDX USB Internal Docking Station for Removable Disk
Cartridge
EU04 S RDX USB External Docking Station for Removable Disk
Cartridge
EU07 S RDX SATA Internal Docking Station for Removable Disk
Cartridge
EU08 S RDX 320 GB Removable Disk Drive
EU11 A 2.5/6.25TB LTO-6 SAS Tape Drive, Half-high
EU15 S 1.5TB Removable Disk Drive Cartridge
EU16 S 80/160GB DAT160 USB Tape Drive
EU17 A 2.5 TB LTO-6 Tape Cartridge
EU18 A 5-Pack of #EU17
EU19 S Cable Ties & Labels
EU24 S Cognos on Power - Small
EU25 S Cognos on Power - Large
EU28 S 25th Anniversary Edition
EU29 A Order Placed Indicator
EU2T A 2TB Removable Disk Drive Cartridge (RDX)
EUC0 S Software preload define
EUC1 S Software preload define
EUC2 S Software preload define
EUC3 S Software preload define
EUC6 A Core Use HW Feature
EUC7 A Core Use HW Feature 10X
Feature descriptions
The following is a list of all feature codes in numeric order for the IBM Power Systems 8205 machine type.
Attributes, as defined in the following feature descriptions, state the interaction of requirements among features.
Minimums and maximums are the absolute limits for a single feature without regard to interaction with other features. The maximum valid quantity for MES orders may be different than for initial orders. The maximums listed below refer to the largest quantity of these two possibilities.
The order type defines if a feature is orderable only on initial orders, only on MES orders, on both initial and MES orders, or if a feature is supported on a model due to a model conversion. Supported features cannot be ordered on the converted model, only left on or removed from the converted model.
(#0004) - EMEA Bulk MES Indicator
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#0004)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#0010) - One CSC Billing Unit
One Billing Unit used by the Customer Solution Center.
- Attributes provided: One CSC Billing Unit
- Attributes required: None
- For 8205-E6D: (#0010)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0011) - Ten CSC Billing Units
Ten Billing Units used by the Customer Solutions Center.
- Attributes provided: Ten CSC Billing Units
- Attributes required: None
- For 8205-E6D: (#0011)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0040) - Mirrored System Disk Level, Specify Code
This code indicates the level of disk protection desired and helps ensure that adequate hardware is in the final configuration.
- Attributes provided: Device-level mirrored protection
- Attributes required: Minimum of two (2) disk units
- For 8205-E6D: (#0040)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0041) - Device Parity Protection-All, Specify Code
This code indicates the level of disk protection desired and helps ensure that adequate hardware is in the final configuration.
- Attributes provided: RAID Data Protection
- Attributes required: RAID-capable disk unit controller
- For 8205-E6D: (#0041)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0043) - Mirrored System Bus Level, Specify Code
This code indicates the level of disk protection desired and helps ensure that adequate hardware is in the final configuration.
For new systems: The marketing configurator will error on an order if sufficient disk units, and expansion units are not included on the order to support bus-level mirrored protection for all disk units. New, preloaded systems will be shipped with bus-level mirroring enabled.
- Attributes provided: Bus-level mirrored protection
- Attributes required: Minimum of 2 (two) disk units
- For 8205-E6D: (#0043)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0047) - Device Parity RAID-6 All, Specify Code
This code indicates the level of disk protection desired and helps ensure that adequate hardware is in the final configuration.
- Attributes provided: RAID-6 Data Protection
- Attributes required: RAID-6 capable disk unit controller
- For 8205-E6D: (#0047)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0098) - Special Manufacturing Operations Indicator
This feature is a no-charge feature that indicates special manufacturing operations are to be performed.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#0098)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0205) - RISC-to-RISC Data Migration
(No Longer Available as of November 30, 2015)
#0205 is used on initial orders to designate that the new server should only receive a partial load of IBM i in IBM Mfg.
When #0205 is on the order, manufacturing will only load SLIC and up through QSYS of IBM i. Ensure that enough storage is ordered to contain the additional OS code that will be loaded following installation of the system at the Client location. Specify code #0205 is mutually exclusive with #5000, SW Preload Required
The migration process requires that the installed model be at the same version and release level of IBM i and other licensed programs as the new server.
More information, and an updated IBM i Upgrade and Data Migration Road Map (RISC-RISC) are available at
- Attributes provided: Partial load of IBM i in IBM Mfg.
- Attributes required: #2145 - Primary OS - IBM i and partition specify code #0267 and RISC to RISC Data Migration from Clients existing system
- For 8205-E6D: (#0205)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#0265) - AIX Partition Specify
This feature indicates customers intend to create a partition on the system that will use the AIX operating system. This feature should be included once for each intended AIX partition. This feature is an indicator and does not deliver parts, software, or services.
- Attributes provided: None
- Attributes required: Customers intend to create a partition on the system that will run the AIX operating system.
- For 8205-E6D: (#0265)
- Minimum required: 0
- Maximum allowed: 320 (Initial order maximum: 320)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0266) - Linux Partition Specify
This feature indicates customers intend to create a partition on the system that will use the Linux operating system. This feature should be included once for each intended Linux partition. This feature is an indicator and does not deliver parts, software, or services.
- Attributes provided: None
- Attributes required: Customers intend to create a partition on the system that will run the Linux operating system.
- For 8205-E6D: (#0266)
- Minimum required: 0
- Maximum allowed: 320 (Initial order maximum: 320)
- OS level required:
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0267) - IBM i Operating System Partition Specify
This feature indicates customers intend to create a partition on the system that will use the IBM i operating system. This feature should be included once for each intended IBM i partition. This feature is an indicator and does not deliver parts, software, or services.
- Attributes provided: None
- Attributes required: Customers intend to create a partition on the system that will run the IBM i operating system.
- For 8205-E6D: (#0267)
- Minimum required: 0
- Maximum allowed: 320 (Initial order maximum: 320)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0296) - Specify Custom Data Protection
#0296 specifies that a system has multiple IBM i partitions and that data protection schemes should be considered separately for each partition instead of only for an overall system level. Each partition's data protection scheme can be different or the same.
- Attributes provided: N/A
- Attributes required: N/A
- For 8205-E6D: (#0296)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0308) - Mirrored Level System Specify Code
This specify code indicates the level of disk protection desired and helps ensure that adequate hardware is in the final configuration.
For new systems, the marketing configurator will show an error if sufficient disk units and disk controllers are not included on the order to support IOA-level mirroring protection. #0308 causes all disk units to be placed into configurations capable of IOA-level mirroring. Each disk unit and its mirrored pair must be on a different disk controller.
Note that the load source disk unit in a new, preloaded system will be device-level mirrored (same protection as provided with feature #0040). This means that the load source is controlled by the first disk unit controller on the first system bus, and will be mirrored with a like disk unit that is also attached to the same first disk controller on the first system bus.
For upgrade orders, #0308 will cause the marketing configurator to show an error if sufficient disk units and disk controllers are not available to provide the capability to enable IOA-level mirrored protection for all DASD.
It is the client's responsibility to start mirroring on their system.
- Attributes provided: IOA level system mirroring
- Attributes required: A minimum of two disk controllers and an even number of disk units (with a minimum of four disk units on a system).
- For 8205-E6D: (#0308)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0347) - RAID Hot Spare Specify
#0347 is a specify code that indicates to IBM configuration tools and to IBM Manufacturing that RAID-5 or RAID-6 disk arrays should be further protected using the IBM i function of RAID hot spare. If specified, IBM will ship a configuration which has at least one stand- by disk drive for each disk controller in the system or designated partition. The customer may alter the hot spare configuration selecting different options once the system is installed.
- Attributes provided: N/A
- Attributes required: Existence of #0041 or #0047
- For 8205-E6D: (#0347)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0348) - V.24/EIA232 6.1m (20-Ft) PCI Cable
This feature provides a 20-foot WAN PCI cable that supports a V.24 or a EIA232 electrical connection interface.
- Attributes provided: N/A
- Attributes required: N/A
- For 8205-E6D: (#0348)
- Minimum required: 0
- Maximum allowed: 120 (Initial order maximum: 120)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0349) - V.24/EIA232 15.2m (50-Ft) PCI Cable
(No Longer Available as of December 15, 2002).
This feature provides a 50-foot WAN PCI cable that supports a V.24 or a EIA232 electrical connection interface.
- Attributes provided: N/A
- Attributes required: N/A
- For 8205-E6D: (#0349)
- Minimum required: 0
- Maximum allowed: 320 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#0353) - V.35 6.1m (20-Ft) PCI Cable
This feature provides a 20-foot WAN PCI cable that supports a V.35 electrical connection interface.
- Attributes provided: N/A
- Attributes required: N/A
- For 8205-E6D: (#0353)
- Minimum required: 0
- Maximum allowed: 320 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0354) - V.35 15.2m (50-Ft) PCI Cable
(No Longer Available as of December 15, 2002).
This feature provides a 50-foot WAN PCI cable that supports a V.35 electrical connection interface.
- Attributes provided: N/A
- Attributes required: N/A
- For 8205-E6D: (#0354)
- Minimum required: 0
- Maximum allowed: 320 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#0356) - V.36 6.1m (20-Ft) PCI Cable
(No Longer Available as of December 1, 2007)
This feature provides a 20-foot WAN PCI cable that supports a V.36 electrical connection interface.
- Attributes provided: N/A
- Attributes required: N/A
- For 8205-E6D: (#0356)
- Minimum required: 0
- Maximum allowed: 320 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#0359) - X.21 6.1m (20-Ft) PCI Cable
This feature provides a 20-foot WAN PCI cable that supports a X.21 electrical connection interface.
- Attributes provided: N/A
- Attributes required: N/A
- For 8205-E6D: (#0359)
- Minimum required: 0
- Maximum allowed: 320 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0360) - X.21 15.2m (50-Ft) PCI Cable
(No Longer Available as of December 15, 2002).
This feature provides a 50-foot WAN PCI cable that supports a X.21 electrical connection interface.
- Attributes provided: N/A
- Attributes required: N/A
- For 8205-E6D: (#0360)
- Minimum required: 0
- Maximum allowed: 320 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#0365) - V.24/EIA232 (80-Ft) PCI Cable
(No Longer Available as of December 15, 2002).
This feature provides a 80-foot WAN PCI cable that supports a V.24 electrical connection interface.
- Attributes provided: N/A
- Attributes required: N/A
- For 8205-E6D: (#0365)
- Minimum required: 0
- Maximum allowed: 320 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#0368) - V.24/EIA232 20-Ft. PCI Cable with M3
This feature provides a 20-foot WAN PCI cable that supports a V.24 or an EIA232 electrical interface with M3 attachment screws. For Germany.
- Attributes provided: Cable
- Attributes required: None
- For 8205-E6D: (#0368)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 9999)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0444) - CBU Specify
(No Longer Available as of November 30, 2015)
This specify code indicates this system has been properly registered as a Capacity BackUp system and has, through that registration been authorized to temporarily receive IBM i Operating System License Entitlements and either 5250 Processor Enablement entitlements or IBM i user entitlements, from a primary system under the conditions specified at the time the system was registered. This feature is an indicator only, authorization to use this system as a backup is obtained only by registering the system with IBM on the CBU website at
- www.ibm.com/systems/power/hardware/cbu
- Attributes provided: Indicates the system has been registered for use as a CBU system for IBM i License entitlement purposes.
- Attributes required: # 2145 Primary OS - IBM i or #0267 IBM i Operating System Partition Specify
- For 8205-E6D: (#0444)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Initial
- CSU: Yes
- Return parts MES: No
(#0456) - Customer Specified Placement
(No Longer Available as of November 30, 2015)
- Requests that IBM deliver the system to the customer according to the slot in drawer hardware placement defined by the account team.
- Eliminates the need to have these parts relocated in the customers environment as may happen if the order is placed without this feature code.
- Client placement specifications are collected using the System Planning Tool (SPT) and processed through the marketing configurator. (Use of the SPT is not required).
- Requires account team to submit the output of the marketing
configurator into IBM manufacturing via the CSP website
(US Business Partners and Distributors can bypass this step.)
- Requires account team to assure that the marketing configurator output submitted reflects the actual order placed.
- Attributes provided: I/O component placement
- Attributes required: Marketing Configurator output submitted to the CSP website. (US Business Partners and Distributors can bypass this step.)
- For 8205-E6D: (#0456)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#0462) - SSD Placement Indicator - CEC
This is an IBM internal automatic generated SSD specify indicator for placement and it is not selectable.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#0462)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0463) - SSD Placement Indicator (5802/5803)
(No Longer Available as of November 30, 2015)
This is an IBM internal automatic generated SSD specify indicator for placement and it is not selectable.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#0463)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#0464) - SSD Placement Indicator - 5886
(No Longer Available as of November 30, 2015)
This is an IBM internal automatic generated SSD specify indicator for placement and it is not selectable.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#0464)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#0465) - SSD Placement Indicator - 5887
(No Longer Available as of November 30, 2015)
This is an IBM internal automatic generated SSD specify indicator for placement and it is not selectable.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#0465)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#0551) - 19 inch, 1.8 meter high rack
(No Longer Available as of March 31, 2018)
Provides a 19 inch, 1.8 meter high rack with 36 EIA units of total space for installing rack mounted CECs and/or expansion units. One of the following features are required on the #0551:
- #6068 - Optional Front Door for 1.8m Rack
- #6263 - 1.8m Rack Trim Kit
- #6248 - 1.8m Rack Acoustic Doors
The following features are also orderable on the #0551:
- #0599 - Rack Filler Panel Kit
- #6580 - Optional Rack Security Kit
- #7840 - Side-By-Side for 1.8m Racks
- #7841 - Ruggedize Rack Kit
The #0551 can support up to eight PDUs, four mounted vertically and four mounted horizontally. Each PDU mounted horizontally takes up 1 EIA of rack space. The following PDUs are supported:
- #7188 - Power Distribution Unit (12, C-13 sockets)
- #7109 - Power Distribution Unit (12, C-13 sockets)
- Attributes provided: 19 inch, 1.8M, 36 EIA Rack
- Attributes required: #6068 or #6246 or #6248 or #6263.
- For 8205-E6D: (#0551)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#0553) - 19 inch, 2.0 meter high rack
(No Longer Available as of March 31, 2018)
Provides a 19-inch, 2.0 meter high rack with 42 EIA units of total space for installing rack mounted CECs and/or expansion units. One of the following features are required on the #0553:
- #6069 - Optional Front Door for 2.0m Rack
- #6247 - 2.0m Rack Trim Kit (w/d 5/28/2010)
- #6272 - 2.0m Rack Trim Kit
- #6249 - 2.0m Rack Acoustic Doors
The #0553 can support up to nine power distribution units (PDU), four mounted vertically and five mounted horizontally. Each PDU mounted horizontally takes up 1 EIA of rack space. The following PDUs are supported:
- #7188 - Power Distribution Unit (12, C13 sockets)
- #7109 - Power Distribution Unit (12, C13 sockets)
- Attributes provided: 19 inch, 2.0M, 42 EIA Rack
- Attributes required: #6069 or #6247 or #6272 or #6249
- For 8205-E6D: (#0553)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#0555) - 19 inch, 1.3 meter high rack
Provides a 19-inch, 1.3 meter (49-inch) high rack with 25 EIA units of total space for installing rack-mounted CECs and/or expansion units. The #0555 includes lockable front and rear doors. Filler panels and perforated doors are included to help provide proper airflow and cooling.
PDU and power cord features are available for ordering with the rack. This rack does not feature side pockets for PDU mounting. All PDUs must mount horizontally in EIA space.
- Attributes provided: 19 inch, 1.3M, 25 EIA Rack
- Attributes required: None
- For 8205-E6D: (#0555)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#0566) - IBM i 6.1 with 6.1.1 Machine Code Specify Code
This feature is used to indicate the correct level of code when IBM i is specified.
- Attributes provided: IBM i 6.1 with 6.1.1 Machine Code Indicator
- Attributes required: IBM i operating system
- For 8205-E6D: (#0566)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required:
- IBM i 6.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note: One Per Order
(#0567) - IBM i 7.1 Specify Code
(No longer available as of October 19, 2018)
This feature is used to indicate the correct level of code when IBM i is specified.
- Attributes provided: IBM i 7.1 indicator
- Attributes required: IBM i operating system
- For 8205-E6D: (#0567)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required:
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0599) - Rack Filler Panel Kit
Provides rack filler panels for IBM 19-inch racks. The #0599 provides three 1-EIA -unit filler panels and one 3-EIA-unit filler panel. These are snap-on panels.
- Attributes provided: Snap on rack filler panels
- Attributes required: 19-inch rack
- For 8205-E6D: (#0599)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0710) - Balanced Warehouse Solution Indicator
(No Longer Available as of November 30, 2015)
This feature specifies that the DS4000 EXP810 ordered will be a component of the Balanced Warehouse Solution. This feature will automatically be selected by the configurator when a Balanced Warehouse solution is configured. The solution will be integrated at the Customer Solution Center.
- Attributes provided: none
- Attributes required: none
- For 8205-E6D: (#0710)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#0712) Power Cloud Solution Integrated Solution Indicator for Order Routing
(No Longer Available as of November 30, 2015)
A manufacturing routing code used to route orders to the Custom Solution Center for assembly .
- Attributes provided: Manufacturing Routing Code
- Attributes required: None
- For 8205-E6D: (#0712)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#0719) - Load Source Not in CEC
This specify feature indicates to the IBM Marketing configurator tools and IBM manufacturing that disk drives will not be placed in the system unit, but will be placed in I/O drawers or in external SAN attached disk.
- Attributes provided: System unit(s) are shipped with no disk units placed inside.
- Attributes required: Alternate load source specified
- For 8205-E6D: (#0719)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: N/A
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0722) - #1787 Load Source Specify
This specify code indicates that a #1787 Disk Unit is being used as the Load Source.
- Attributes provided: Load source specified
- Attributes required: #1787
- For 8205-E6D: (#0722)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: N/A
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0724) - #1996 Load Source Specify
This specify code indicates that a #1996 SSD is being used as the Load Source.
- Attributes provided: None
- Attributes required: #1996
- For 8205-E6D: (#0724)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: N/A
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0726) - Specify Load Source in #5802/#5803/#5877
#0726 Specifies that load source HDD is placed in a #5802/#5803 or SSD (#2055) placed in #5802/#5877 I/O expansion unit.
- Attributes provided: External load source placement capability
- Attributes required: Available SAS drive bay in #5802/#5803 or a SSD (#2055) in #5802/ #5877 I/O expansion unit.
- For 8205-E6D: (#0726)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: N/A
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0727) - Specify #5886 Load Source placement
#0727 Specifies that Load/Source DASD are placed in an EXP 12S SAS DASD drawer.
- Attributes provided: External load source placement specify
- Attributes required: DASD Slot 1 open in drawer
- For 8205-E6D: (#0727)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: N/A
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#0728) - Specify #5887 Load Source placement
#0728 Specifies that Load/Source DASD are placed in an EXP24S SFF Gen2-bay Drawer.
- Attributes provided: External load source placement specify
- Attributes required: DASD Slot 1 open in drawer
- For 8205-E6D: (#0728)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: N/A
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0729) - Specify EXP30 Load Source placement
#0729 Specifies that Load/Source drives are placed in EXP30 Ultra SSD I/O Drawer.
- Attributes provided: External load source placement specify
- Attributes required: SSD bay slot available in drawer
- For 8205-E6D: (#0729)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: N/A
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0837) - SAN Load Source Specify
Indicates that a SAN drive is being used as the Load Source for the operating system.
- Attributes provided: SAN load source placement specify
- Attributes required: Fibre Channel adapter or Fibre Channel over Ethernet Adapter
- For 8205-E6D: (#0837)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: N/A
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0838) - #3676 Load Source Specify
Indicates that a #3676 Disk Unit is being used as the Load Source.
- Attributes provided: None
- Attributes required: feature #3676
- For 8205-E6D: (#0838)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#0839) - #3677 Load Source Specify
Indicates that a #3677 Disk Unit is being used as the Load Source.
- Attributes provided: None
- Attributes required: feature #3677
- For 8205-E6D: (#0839)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0840) - #3678 Load Source Specify
Indicates that a #3678 Disk Unit is being used as the Load Source.
- Attributes provided: None
- Attributes required: feature #3678
- For 8205-E6D: (#0840)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0844) - #3658 Load Source Specify
Indicates that a #3658 Disk Unit is being used as the Load Source.
- Attributes provided: None
- Attributes required: feature #3658
- For 8205-E6D: (#0844)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0851) - #1884 Load Source Specify
This specify code indicates that a #1884 Disk Unit is being used as the Load Source.
- Attributes provided: None
- Attributes required: Feature #1884
- For 8205-E6D: (#0851)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#0853) - #1888 Load Source Specify
This specify code indicates that a #1888 Disk Unit is being used as the Load Source.
- Attributes provided: None
- Attributes required: #1888
- For 8205-E6D: (#0853)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0855) - #3587 Load Source Specify
- Attributes provided: None
- Attributes required: Feature #3587
- For 8205-E6D: (#0855)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#0856) - #1911 Load Source Specify
- Attributes provided: None
- Attributes required: Feature #1911
- For 8205-E6D: (#0856)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0857) - #1916 Load Source Specify
The specify code indicates that a #1916 571GB SAS SFF disk drive is being used as the Load Source.
- Attributes required: #1916
- For 8205-E6D: (#0857)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0870) - #1879 Load Source Specify
This specify code indicates that a #1879 Disk Unit is being used as the Load Source.
- Attributes provided: None
- Attributes required: Feature #1879
- For 8205-E6D: (#0870)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0871) - #1947 Load Source Specify
This specify code indicates that a #1947 Disk Unit is being used as the Load Source.
- Attributes provided: None
- Attributes required: Feature #1947
- For 8205-E6D: (#0871)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0872) - #1948 Load Source Specify
This specify code indicates that a #1948 Disk Unit is being used as the Load Source.
- Attributes provided: None
- Attributes required: Feature #1948
- For 8205-E6D: (#0872)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0874) - #1956 Load Source Specify
This specify code indicates that a #1956 Disk Unit is being used as the Load Source.
- Attributes provided: None
- Attributes required: Feature #1956
- For 8205-E6D: (#0874)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0875) - #1962 Load Source Specify
This specify code indicates that a #1962 Disk Unit is being used as the Load Source.
- Attributes provided: None
- Attributes required: Feature #1962
- For 8205-E6D: (#0875)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0876) - #1794 Load Source Specify
This specify code indicates that a #1794 Disk Unit is being used as the Load Source.
- Attributes provided: None
- Attributes required: Feature #1794
- For 8205-E6D: (#0876)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0879) - #1737 Load Source Specify (856GB SFF-1 disk)
(No Longer Available as of January 20, 2017)
This specify code indicates that a #1737 Disk Unit is being used as the Load Source.
- Attributes provided: None
- Attributes required: Feature #1737
- For 8205-E6D: (#0879)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0880) - #1738 Load Source Specify (856GB SFF-2 disk)
(No Longer Available as of January 20, 2017)
This specify code indicates that a #1738 Disk Unit is being used as the Load Source.
- Attributes provided: None
- Attributes required: Feature #1738
- For 8205-E6D: (#0880)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0882) - #ES04 Load Source Specify
This specify code indicates that a #ES04 Solid State Drive is being used as the Load Source.
- Attributes provided: None
- Attributes required: Feature #ES04
- For 8205-E6D: (#0882)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0893) - #ES0B Load Source Specify
This specify code indicates that a #ES0B Solid State Drive is being used as the Load Source.
- Attributes provided: Feature ES0B
- Attributes required: None
- For 8205-E6D: (#0893)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0894) - #ES0D Load Source Specify
This specify code indicates that a #ES0D Solid State Drive is being used as the Load Source.
- Attributes provided: Feature ES0D
- Attributes required: None
- For 8205-E6D: (#0894)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0907) - #ESD0 Load Source Specify (1.1TB 10k SFF-1)
Indicates that a #ESD0 (1.1 TB 10k rpm SFF-1 disk drive) is being used as the Load Source.
- Attributes provided: None
- Attributes required: ESD0
- For 8205-E6D: (#0907)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#0911) - #ESD2 Load Souce Specify (1.1TB 10k SFF-2)
Indicates that a #ESD2 (1.1 TB 10k rpm SFF-2 disk drive) is being used as the Load Source.
- Attributes provided: None
- Attributes required: ESD2
- For 8205-E6D: (#0911)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 6.1 with machine code 6.1.1, or later
- IBM i 7.1, or later
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1010) - Modem Cable - Austria
Austria modem cable, use with #2893, 6808 and 6833 or similar modem adapters. Maximum of two per adapter.
- For 8205-E6D: (#1010)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: N/A
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1011) - Modem Cable - Belgium
Belgium modem cable, use with #2893, 6808 and 6833 or similar modem adapters. Maximum of two per adapter.
- For 8205-E6D: (#1011)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: N/A
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1012) - Modem Cable - Africa
Africa modem cable, use with #2893, 6808 and 6833 or similar modem adapters. Maximum of two per adapter.
- For 8205-E6D: (#1012)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: N/A
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1014) - Modem Cable - Italy
Italy modem cable, use with #2893, 6808 and 6833 or similar modem adapters. Maximum of two per adapter.
- For 8205-E6D: (#1014)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: N/A
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1015) - Modem Cable - France
France modem cable use with #2893, 6808 and 6833 or similar modem adapters. Maximum of two per adapter.
- For 8205-E6D: (#1015)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: N/A
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1016) - Modem Cable - Germany
Germany modem cable, use with #2893, 6808 and 6833 or similar modem adapters. Maximum of two per adapter.
- For 8205-E6D: (#1016)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: N/A
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1017) - Modem Cable - UK
United Kingdom modem cable, use with #2893, 6808 and 6833 or similar modem adapters. Maximum of two per adapter.
- For 8205-E6D: (#1017)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: N/A
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1018) - Modem Cable - Iceland/Sweden
Iceland/Sweden modem cable, use with #2893, 6808 and 6833 or similar modem adapters. Maximum of two per adapter.
- For 8205-E6D: (#1018)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: N/A
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1021) - Modem Cable - Fin/Nor
Finland/Norway modem cable, use with #2893, 6808 and 6833 or similar modem adapters. Maximum of two per adapter.
- For 8205-E6D: (#1021)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: N/A
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1022) - Modem Cable - Netherlands
Netherlands modem cable, use with #2893, 6808 and 6833 or similar modem adapters. Maximum of two per adapter.
- For 8205-E6D: (#1022)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: N/A
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1023) - Modem Cable - Swiss
Switzerland modem cable, use with #2893, 6808 and 6833 or similar modem adapters. Maximum of two per adapter.
- For 8205-E6D: (#1023)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: N/A
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1024) - Modem Cable - Denmark
Denmark modem cable, use with #2893, 6808 and 6833 or similar modem adapters. Maximum of two per adapter.
- For 8205-E6D: (#1024)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: N/A
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1025) - Modem Cable - US/Canada and General Use
Modem cable, use with #2893, 6808 and 6833 or similar modem adapters. Maximum of two per adapter. Select this cable for use with your modem if there is not another cable feature that is identified as specific to your country.
- For 8205-E6D: (#1025)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: N/A
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1103) - USB Internal Docking Station for Removable Disk Drive
USB Internal Docking Station accommodates a removable RDX disk cartridge. The disks are in a protective rugged enclosure that plug into the docking station. Docking station holds one removable rugged disk drive/cartridge at a time. The rugged removable disk cartridge and docking station backs up similar to tape drive. This can be an excellent alternative to DAT72, DAT160, 8mm, and VXA-2 and VXA-320 tapes.
Highlights
- USB 2.0
- RDX docking station
- Suitable for backup and restore as an alternative to using tape drives
- Attributes provided: USB Internal Docking Station
- Attributes required: One internal USB port and at least one RDX disk cartridge such as #1106, #1107 or #EU01. Requires HH bay in system unit. Can not be installed concurrently with a tape drive in the HH bay.
- For 8205-E6D: (#1103)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#1104) - USB External Docking Station for Removable Disk Drive
USB external Docking Station accommodates a removable RDX disk drive/cartridge. The disks are in a protective rugged enclosure that plug into the docking station. Docking station holds one removable rugged disk cartridge at a time. The rugged removable disk cartridge and docking station backs up similar to tape drive. This can be an excellent alternative to DAT72, DAT160, 8mm, and VXA-2 and VXA-320 tapes.
Highlights
- USB 2.0
- RDX docking station
- Suitable for backup and restore as an alternative to using tape drives
- Attributes provided: USB External Docking Station, 3M USB cable, and 1.8M power cord. Universal Adapter 100-240 VAC, 50-60Hz input providing 15W DC output to the docking station.
- Attributes required: One USB port and at least one RDX disk cartridge such as #1106, #1107 or #EU01.
- For 8205-E6D: (#1104)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note: VIOS - Not Supported
(#1106) - USB 160 GB Removable Disk Drive
Provides a RDX disk drive in a rugged cartridge to be used in an RDX docking station such as #EU03, #EU04, #EU23, #1123, #1103, #1104 or #EU07. 160 GB is uncompressed. Compression/decompression is provided by the operating system, not the drive itself. Feature 1106 is not entitled under the IBM Maintenance Agreement, if one is purchased.
- Attributes provided: 160 GB RDX rugged disk/cartridge
- Attributes required: RDX docking station
- For 8205-E6D: (#1106)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#1107) - USB 500 GB Removable Disk Drive
Provides an RDX disk drive in a rugged cartridge to be used in an RDX Internal and External docking station such as the #1103, #1104, #1123, #EU03, #EU04, #EU23 or #EU07. 500 GB is uncompressed. With typical 2X compression, capacity would be 1000 GB. Compression/ decompression is provided by the operating system, not the drive itself. Feature 1107 is not entitled under the IBM Maintenance Agreement, if one is purchased.
- Attributes provided: 500 GB RDX rugged disk/cartridge
- Attributes required: RDX docking station
- For 8205-E6D: (#1107)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1109) - IBM Ethernet Switch J48E
(No Longer Available as of November 30, 2015)
The IBM Ethernet Switch J48E (4273-E48) with Virtual Chassis technology combines the high availability and carrier-class reliability of modular systems with the economics and flexibility of stackable platforms, delivering a high-performance, scalable solution for data center environments.
The Smart Analytics offering does not use this feature in a public network. Use of this feature in a public network requires it meets country specific homologation requirements.
Reference 4273-E48 sales manual for additional details.
- Attributes provided: IBM Ethernet Switch J48E
- Attributes required: Requires Smart Analytics feature codes #0710
or #1114.
(No Longer Available as of November 30, 2015)
- For 8205-E6D: (#1109)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 2)
- OS level required:
Refer to Software Requirements.
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#1111) - 3m, Blue Cat5e Cable
This 3m Cat5e cable is used with ports/transceivers that have RJ-45 connectors.
- Attributes provided: 3m Cat5e Ethernet Cable
- Attributes required: RJ45 ports/transceivers.
- For 8205-E6D: (#1111)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1112) - 10m, Blue Cat5e Cable
This 10m Cat5e cable is used with ports/transceivers that have RJ-45 connectors..
- Attributes provided: 10m Cat5e Ethernet Cable
- Attributes required: RJ45 ports/transceivers.
- For 8205-E6D: (#1112)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1113) - 25m, Blue Cat5e Cable
This 25m Cat5e cable is used with ports/transceivers that have RJ-45 connectors.
- Attributes provided: 25m Cat5e Ethernet Cable
- Attributes required: RJ45 ports/transceivers.
- For 8205-E6D: (#1113)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1114) - Smart Analytics System routing indicator
- For 8205-E6D: (#1114)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#1115) - CAT5E Ethernet Cable, 3M GREEN
This feature code is used for an integrated solution offering and requires feature codes #1114, #0710, or #0712.
- For 8205-E6D: (#1115)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 9999)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1116) - CAT5E Ethernet Cable, 10M GREEN
This feature code is used for an integrated solution offering and requires feature codes #1114, #0710, or #0712.
- For 8205-E6D: (#1116)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 9999)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1118) - 3m, Yellow Cat5e Cable
This feature code is used for an integrated solution offering and requires feature codes #1114, #0710, or #0712. This cable is used with ports/transceivers that have RJ-45 connectors.
- Attributes provided: 3m Cat5e Ethernet Cable
- Attributes required: RJ45 ports/transceivers.
- For 8205-E6D: (#1118)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1119) - 10m, Yellow Cat5e Cable
This feature code is used for an integrated solution offering and requires feature codes #1114, #0710, or #0712. This cable is used with ports/transceivers that have RJ-45 connectors.
- Attributes provided: 10m Cat5e Ethernet Cable
- Attributes required: RJ45 ports/transceivers.
- For 8205-E6D: (#1119)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1121) - CAT5E Ethernet Cable, 25M YELLOW
This feature code is used for an integrated solution offering and requires feature codes #1114, #0710, or #0712. This cable is used with ports/transceivers that have RJ-45 connectors.
- Attributes provided: 25m Cat5e Ethernet Cable
- Attributes required: RJ45 ports/transceivers.
- For 8205-E6D: (#1121)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 9999)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1135) - Integrated Storage Controller
The Integrated Storage Controller can contain up to 24 300 GB SAS drives. It contains dual redundant, hot-swappable fans and power supplies. The Integrated Storage Controller takes up 2 EIA space in a 19-inch rack.
- Attributes provided: Supports up to 24 drives
- Attributes required: Feature #5273 or #5735. Feature #0710 or #1114.
- For 8205-E6D: (#1135)
- Minimum required: 0
- Maximum allowed: 6 (Initial order maximum: 6)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1136) - Integrated Storage Controller w/ 24 - 600GB drives
(No Longer Available as of November 30, 2015)
The Integrated Storage Controller contains 24 600 GB SAS drives and supports dual redundant, hot-swappable fans and power supplies.
- Attributes provided: Integrated Storage Controller with 24 600 GB SAS drives.
- Attributes required: Requires 2 EIA spaces. Feature #0710 or #1114.
- For 8205-E6D: (#1136)
- Minimum required: 0
- Maximum allowed: 6 (Initial order maximum: 6)
- OS level required:
Refer to Software Requirements.
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#1141) - 1-meter Cable for EXP4500 Switch
This feature provides a 1-meter copper cable for the EXP4500 10 Gb Ethernet switch (#1145). This feature is used for the Smart Analytics offering and requires feature number 1114 or 0710.
- Attributes provided: 1-meter cable
- Attributes required: Feature #1145 and either #1114 or #0710.
- For 8205-E6D: (#1141)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1143) - 3-meter Cable for EXP4500 Switch
This feature provides a 3-meter copper cable for the EXP4500 10 Gb Ethernet switch (#1145). This feature is used for the Smart Analytics offering and requires feature number 1114 or 0710.
- Attributes provided: 3-meter cable
- Attributes required: Feature #1145 and either #1114 or #0710
- For 8205-E6D: (#1143)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1148) - EX4500 10GB Optical Transceiver
#1148 provides a 10GB Juniper EX4500 optical transceiver. The Juniper EX4500 supports up to 48 10GB pluggable optical transceivers ports for connectivity to networked devices such as servers and other switches.
- Attributes provided: 10GB Optical transceiver for Juniper EX4500 switch
- Attributes required: Requires Smart Analytics feature codes #0710 or #1114.
- For 8205-E6D: (#1148)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 2)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1406) - 200V 16A 4.3m (14-Ft) TL Line Cord
(No Longer Available as of December 1, 2007)
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#1406)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#1408) - 4.3m 200V/16A Pwr Cd Italy
This feature provides a 4.3m 200V 16A line cord for use in Italy.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#1408)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#1413) - 125V 4.3m (14-Ft) Line Cord
(No Longer Available as of April 15, 2005)
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#1413)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#1414) - 200V 1.8m (6-Ft) Locking Line Cord
(No Longer Available as of December 1, 2007)
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#1414)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#1418) - 4.3m 200V/16A Power Cord S. Africa
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#1418)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#1419) - 4.3m 200V/16A Power Cord Israel
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#1419)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#1420) - 4.3m 200V/16A Power Cord EU/Asia
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#1420)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#1421) - 4.3m 200V/16A Power Cord CH/DK
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#1421)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#1426) - 200V 4.3m (14-Ft) Locking Line Cord
(No Longer Available as of January 15, 2005)
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#1426)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#1439) - 4.3m 200V/10A Power Cord EU/Asia
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#1439)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#1440) - 4.3m 200V/10A Power Cord Denmark
(No Longer Available as of December 1, 2007)
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#1440)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#1441) - 4.3m 200V/10A Power Cord S. Africa
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#1441)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#1442) - 4.3m 200V/10A Power Cord Swiss
(No Longer Available as of December 1, 2007)
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#1442)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#1443) - 4.3m 200V/10A Power Cord UK
(No Longer Available as of December 1, 2007)
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#1443)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#1445) - 4.3m 200V/10A Power Cord Israel
(No Longer Available as of December 1, 2007)
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#1445)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#1449) - 4.3m 200V/32A Power Cord EU 1-PH
(No Longer Available as of January 15, 2005)
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#1449)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#1450) - 4.3m 200V/16A Power Cord EU 2-PH
(No Longer Available as of October 15, 2004)
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#1450)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#1476) - 4.3m 200V/12A Pwr Cd UK
- Attributes provided: N/A
- Attributes required: N/A
- For 8205-E6D: (#1476)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#1477) - 4.3m 200V/16A Pwr Cd
- Attributes provided: N/A
- Attributes required: N/A
- For 8205-E6D: (#1477)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#1737) - 856GB 10k RPM SAS SFF Disk Drive (IBM i)
856GB SFF 10k rpm SAS drive in Gen1 SFF carrier. Supported in SFF SAS bays such as provided in most POWER7 system units or the #5802/ 5803 I/O drawers. Disk is formatted for 528 byte sectors.
The drive can be reformatted to 512 byte sectors and then used by AIX/Linux/VIOS.
Limitation: can not be used in #5887 EXP24S Gen2 I/O drawer due to physical difference in Gen1 and Gen2 carriers.
- Attributes provided: 856GB of Disk Storage mounted Gen-1 carrier
- Attributes required: one SFF SAS disk drive bay slot
- For 8205-E6D: (#1737)
- Minimum required: 0
- Maximum allowed: 80 (Initial order maximum: 80)
- OS level required:
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 8 supported in the CEC
- System maximum of 80 with 8 in the CEC and 72 in 4 x #5802
(#1738) - 856GB 10k RPM SAS SFF-2 Disk Drive (IBM i)
(No Longer Available as of January 20, 2017)
856GB SFF 10k rpm SAS drive in gen 2 SFF carrier. Supported in SFF SAS bays such as provided in #5887 EXP24S Gen2 I/O drawer. Disk is formatted for 528 byte sectors.
The drive can be reformatted to 512 byte sectors and used by AIX/ Linux/VIOS
Limitation: can not be used in #5802/5803 I/O drawers or in CEC bays due to physical difference in Gen1 and Gen2 carriers.
- Attributes provided: 856GB of Disk Storage mounted in a Gen2 carrier
- Attributes required: one SFF SAS disk drive bay
- For 8205-E6D: (#1738)
- Minimum required: 0
- Maximum allowed: 336 (Initial order maximum: 250)
- OS level required:
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 8 supported in the CEC
- System maximum of 80 with 8 in the CEC and 72 in 4 x #5802
(#1751) - 900GB 10K RPM SAS SFF Disk Drive (AIX/Linux)
(No Longer Available as of January 20, 2017)
900GB SFF 10k rpm SAS drive in gen-1 SFF carrier. Supported in SFF SAS bays such as provided in most POWER7 system units or the #5802/5803 I/O drawers. Disk is formatted for 512 byte sectors.
The drive can be reformatted to 528 byte sectors and then used by IBM i/AIX/Linux/VIOS
Limitation: can not be used in #5887 EXP24S Gen2 I/O drawer due to physical difference in Gen1 and Gen2 carriers.
- Attributes provided: 900GB of disk storage mounted in a gen-1 carrier.
- Attributes required: One SFF SAS disk drive bay slot
- For 8205-E6D: (#1751)
- Minimum required: 0
- Maximum allowed: 80 (Initial order maximum: 80)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 8 supported in the CEC
- System maximum of 80 with 8 in the CEC and 72 in 4 x #5802
(#1752) - 900GB 10k RPM SAS SFF-2 Disk Drive (AIX/Linux)
(No Longer Available as of January 20, 2017)
900GB SFF 10k rpm SAS drive in Gen-2 carrier. Supported in SFF SAS bays such as provided in #5887 EXP24S Gen2 I/O drawer. Disk is formatted for 512 byte sectors.
The drive can be reformatted to 528 byte sectors and then used by IBM i/AIX/Linux/VIOS
Limitation: can not be used in #5802/5803 I/O drawers or in CEC SFF bays due to physical difference in Gen1 and Gen2 carriers.
- Attributes provided: 900GB of Disk Storage mounted in a Gen2 carrier
- Attributes required: one SFF (SFF-2) SAS GEN2 drive bay
- For 8205-E6D: (#1752)
- Minimum required: 0
- Maximum allowed: 336 (Initial order maximum: 250)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 8 supported in the CEC
- System maximum of 80 with 8 in the CEC and 72 in 4 x #5802
(#1775) - 177GB SFF-1 SSD w/ eMLC (AIX/Linux)
(No Longer Available as of August 23, 2013)
The 177GB SFF SAS Solid State Drive (SSD) provides 177 GB of very high performance storage, much faster than spinning disk drives with their delays due to positioning the disk arm and waiting for the spinning disk to rotate under the arm.
The drive is formatted to 528 byte sectors providing 177 GB and can be used by AIX, Linux (#1775) and IBM i (#1787). #1775 and #1787 are identical drives, but have different feature codes to help the IBM configuration tools understand how the SSD is used. The drive is supported in SFF SAS bays in the #5802/#5803 I/O drawers or system unit SAS bays. CCIN is 58B3.
Limitation: can not be used in #5887 EXP24S Gen2 I/O drawer due to physical difference in Gen1 and Gen2 carriers.
- Attributes provided: 177GB SFF-1 SSD w/ eMLC (AIX/Linux)
- Attributes required: One SFF-1 SAS bay
- For 8205-E6D: (#1775)
- Minimum required: 0
- Maximum allowed: 80 (Initial order maximum: 80)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 8 supported in the CEC
- System maximum of 80 with 8 in the CEC and 72 in 4 x #5802
(#1787) - 177GB SFF-1 SSD w/ eMLC (IBM i)
(No Longer Available as of August 23, 2013)
The 177GB SFF SAS Solid State Drive (SSD) provides 177 GB of very high performance storage, much faster than spinning disk drives with their delays due to positioning the disk arm and waiting for the spinning disk to rotate under the arm.
The drive is formatted to 528 byte sectors providing 177 GB and can be used by AIX, Linux (#1775) and IBM i (#1787). #1775 and #1787 are identical drives, but have different feature codes to help the IBM configuration tools understand how the SSD is used. The drive is supported in SFF SAS bays in the #5802/#5803 I/O drawers or system unit SAS bays. CCIN is 58B3.
Limitation: can not be used in #5887 EXP24S Gen2 I/O drawer due to physical difference in Gen1 and Gen2 carriers.
- Attributes provided: 177GB SFF-1 SSD w/ eMLC (IBM i)
- Attributes required: One SFF-1 SAS bay
- For 8205-E6D: (#1787)
- Minimum required: 0
- Maximum allowed: 80 (Initial order maximum: 80)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 8 supported in the CEC
- System maximum of 80 with 8 in the CEC and 72 in 4 x #5802
(#1790) - 600GB 10K RPM SAS SFF Disk Drive (AIX/Linux)
(No Longer Available as of March 31, 2018)
600GB SFF 10k rpm SAS drive in gen-1 SFF carrier. Supported in SFF SAS bays such as provided in most POWER7 system units or the #5802/5803 I/O drawers. Disk is formatted for 512 byte sectors.
Limitation: can not be used in #5887 EXP24S Gen2 I/O drawer due to physical difference in Gen1 and Gen2 carriers.
- Attributes provided: 600GB of disk storage mounted in a gen-1 carrier.
- Attributes required: One SFF SAS disk drive bay slot
- For 8205-E6D: (#1790)
- Minimum required: 0
- Maximum allowed: 80 (Initial order maximum: 80)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 8 supported in the CEC
- System maximum of 80 with 8 in the CEC and 72 in 4 x #5802
(#1793) - 177GB SFF-2 SSD w/ eMLC (AIX/Linux)
(No Longer Available as of August 23, 2013)
The 177GB SFF SAS Solid State Drive (SSD) provides 177 GB of very high performance storage, much faster than spinning disk drives with their delays due to positioning the disk arm and waiting for the spinning disk to rotate under the arm.
The drive is formatted to 528 byte sectors providing 177 GB and can be used by AIX, Linux (#1793) and IBM i (#1794). #1793 and #1794 are identical drives, but have different feature codes to help the IBM configuration tools understand how the SSD is used. The drive is supported in SFF-2 or gen2 SAS bays such as provided in the #5887 EXP24S I/O drawer. CCIN is 58B4.
Limitation: can not be used in Gen1 Bays such as the #5802/5803 12X PCIe I/O drawer due to physical difference in Gen1 and Gen2 carriers.
- Attributes provided: 177 GB of formatted drive storage mounted in a SFF Gen2 carrier
- Attributes required: One Gen2 SFF SAS drive bay
- For 8205-E6D: (#1793)
- Minimum required: 0
- Maximum allowed: 336 (Initial order maximum: 250)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Not supported in the CEC
- System maximum of 336 in 14 x #5887
(#1794) - 177GB SFF-2 SSD w/ eMLC (IBM i)
(No Longer Available as of August 23, 2013)
The 177GB SFF SAS Solid State Drive (SSD) provides 177 GB of very high performance storage, much faster than spinning disk drives with their delays due to positioning the disk arm and waiting for the spinning disk to rotate under the arm.
The drive is formatted to 528 byte sectors providing 177 GB and can be used by AIX, Linux (#1793) and IBM i (#1794). #1793 and #1794 are identical drives, but have different feature codes to help the IBM configuration tools understand how the SSD is used. The drive is supported in SFF-2 or gen2 SAS bays such as provided in the #5887 EXP24S I/O drawer. CCIN is 58B4.
Limitation: can not be used in Gen1 Bays such as the #5802/5803 12X PCIe I/O drawer due to physical difference in Gen1 and Gen2 carriers.
- Attributes provided: 177 GB of formatted drive storage mounted in a SFF Gen2 carrier
- Attributes required: One Gen2 SFF SAS drive bay
- For 8205-E6D: (#1794)
- Minimum required: 0
- Maximum allowed: 336 (Initial order maximum: 250)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Not supported in the CEC
- System maximum of 336 in 14 x #5887
(#1817) - Quantity 150 of #1962
(No Longer Available as of March 31, 2018)
This feature ships a quantity of 150 #1962 disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records.
- Attributes provided: see feature #1962
- Attributes required: see feature #1962
- For 8205-E6D: (#1817)
- Minimum required: 0
- Maximum allowed: 3 (Initial order maximum: 3)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1818) - Quantity 150 of #1964
(No Longer Available as of March 31, 2018)
This feature ships a quantity of 150 #1964 disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records.
- Attributes provided: see feature #1964
- Attributes required: see feature #1964
- For 8205-E6D: (#1818)
- Minimum required: 0
- Maximum allowed: 3 (Initial order maximum: 3)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1827) - System port/UPS Conversion Cable
This cable has 9 pin D-shell receptacle connectors on both ends. Its purpose is to convert an integrated system (serial) port to a UPS attach port. This cable is 0.14m (5.5 inches) long.
- Attributes provided: System (serial) port conversion for UPS attachment
- Attributes required: Integrated CEC system (serial) port or #3930 cable.
- For 8205-E6D: (#1827)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1828) - 1.5 Meter 12X to 4X Channel Conversion Cable
This cable is a 12X channel to 4X channel converter. It supports attaching a 4X Infiniband switch to a 12X channel adapter. It is a 1.5 meter long copper cable. This cable has one 4X channel connector and one 12X channel connector.
- Attributes provided: 12X channel to 4X channel conversion cable
- Attributes required: 12X channel adapter
- For 8205-E6D: (#1828)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1829) - 0.6 Meter 12X Cable
When used with a 19-inch rack mount I/O drawer, this 0.6 Meter cable is used in a 12X channel external I/O Drawer attachment loop between two 12X channel I/O drawers in the same loop.
When used with a 24-inch rack mount I/O drawer, this 0.6 Meter cable is used as a jumper between the two halves of the I/O Drawer when both halves are included in the same 12X loop.
- Attributes provided: 0.6 Meter 12X cable
- Attributes required: none
- For 8205-E6D: (#1829)
- Minimum required: 0
- Maximum allowed: 6 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note: Substitute appropriate cable length SDR/DDR feature 1861, 1862, 1864, or 1865 after October 30, 2009)
(#1830) - 1.5 Meter 12X cable
This 1.5 Meter cable is used to attach a 12X channel I/O Drawer to a 12X channel adapter in the Host system or can be used between two I/O drawers in a 12X channel loop.
Select the 12X cable length, from those offered that best meets your cabling needs. This cable can be attached to I/O Drawer adapters with or without repeaters.
- Attributes provided: 1.5 Meter 12X cable
- Attributes required: none
- For 8205-E6D: (#1830)
- Minimum required: 0
- Maximum allowed: 6 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note: Substitute appropriate cable length SDR/DDR feature 1861, 1862, 1864, or 1865 after October 30, 2009)
(#1834) - 8.0 Meter 12X Cable
This 8 Meter cable is used to attach a 12X channel I/O Drawer to a 12X channel adapter in the Host system or can be used between two I/O drawers in a 12X channel loop.
Select the 12X cable length from those offered that best meets your cabling needs and the cable length restrictions for your application.
- Attributes provided: 8.0 Meter 12X Cable
- Attributes required: none
- For 8205-E6D: (#1834)
- Minimum required: 0
- Maximum allowed: 10 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note: Substitute appropriate cable length SDR/DDR feature 1861, 1862, 1864, or 1865 after October 30, 2009)
(#1840) - 3.0 Meter 12X Cable
This 3 Meter cable is used to attach a 12X channel I/O Drawer to a 12X channel adapter in the Host system or can be used between two I/O drawers in a 12X channel loop.
Select the 12X cable length, from those offered that best meets your cabling needs.
- Attributes provided: 3.0 Meter 12x Cable
- Attributes required: none
- For 8205-E6D: (#1840)
- Minimum required: 0
- Maximum allowed: 10 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note: Substitute appropriate cable length SDR/DDR feature 1861, 1862, 1864, or 1865 after October 30, 2009)
(#1841) - 3 Meter 12X to 4X Channel Conversion Cable
This cable is a 12X channel to 4X channel converter. It supports attaching a 4X Infiniband switch to a 12X channel adapter. It is a 3 meter long copper cable. This cable has one 4X channel connector and one 12X channel connector.
- Attributes provided: 12X channel to 4X channel conversion cable
- Attributes required: 12X channel adapter
- For 8205-E6D: (#1841)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1844) - Quantity 150 of #1956
(No Longer Available as of July 8, 2016)
This feature ships a quantity of 150 #1956 disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records.
- Attributes provided: see feature #1956
- Attributes required: see feature #1956
- For 8205-E6D: (#1844)
- Minimum required: 0
- Maximum allowed: 3 (Initial order maximum: 3)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1854) - 10 Meter 12X to 4X Enhanced Channel Conversion Cable
This cable is an enhanced 12X channel to 4X channel converter. It supports attaching a 4X Infiniband switch to a 12X channel adapter. It is a 10 meter long copper cable. This cable has one 4X channel connector and one 12X channel connector.
- Attributes provided: 12X channel to 4X channel conversion cable
- Attributes required: 12X channel adapter
- For 8205-E6D: (#1854)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1861) - 0.6 Meter 12X DDR Cable
When used with a 24-inch rack mount I/O drawer, this 0.6 Meter DDR cable is used as a jumper between the two halves of the I/O Drawer when both halves are included in the same 12X loop.
- Attributes provided: 0.6 Meter 12X DDR cable
- Attributes required: none
- For 8205-E6D: (#1861)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note: Use with #5796, Do not use for looping #5802
(#1862) - 1.5 Meter 12X DDR Cable
This 1.5 Meter DDR cable is used to attach a 12X channel I/O Drawer to a 12X channel adapter in the Host system or can be used between two I/O drawers in a 12X channel loop.
- Attributes provided: 1.5 Meter 12X DDR cable
- Attributes required: none
- For 8205-E6D: (#1862)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1864) - 8.0 Meter 12X DDR Cable
This 8 Meter DDR cable is used to attach a 12X channel I/O Drawer to a 12X channel adapter in the Host system or can be used between two I/O drawers in a 12X channel loop.
- Attributes provided: 8 Meter 12X DDR Cable
- Attributes required: None
- For 8205-E6D: (#1864)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1865) - 3.0 Meter 12X DDR Cable
This 3 Meter DDR cable is used to attach a 12X channel I/O Drawer to a 12X channel adapter in the Host system or can be used between two I/O drawers in a 12X channel loop.
Select the 12X DDR cable length from those offered that best meets your cabling needs and the cable length restrictions for your application.
- Attributes provided: 3 Meter 12X DDR Cable
- Attributes required: None
- For 8205-E6D: (#1865)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1866) - Quantity 150 of #1917
(No Longer Available as of July 8, 2016)
This feature ships a quantity of 150 #1917 disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records.
- Attributes provided: see feature #1917
- Attributes required: see feature #1917
- For 8205-E6D: (#1866)
- Minimum required: 0
- Maximum allowed: 3 (Initial order maximum: 3)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1868) - Quantity 150 of #1947
(No Longer Available as of July 8, 2016)
This feature ships a quantity of 150 #1947 disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records.
- Attributes provided: see feature #1947
- Attributes required: see feature #1947
- For 8205-E6D: (#1868)
- Minimum required: 0
- Maximum allowed: 3 (Initial order maximum: 3)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1869) - Quantity 150 of #1925
(No Longer Available as of July 8, 2016)
This feature ships a quantity of 150 #1925 disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records.
- Attributes provided: see feature #1925
- Attributes required: see feature #1925
- For 8205-E6D: (#1869)
- Minimum required: 0
- Maximum allowed: 3 (Initial order maximum: 3)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1879) - 283GB 15K RPM SAS SFF Disk Drive (IBM i)
(No Longer Available as of March 31, 2018)
283 GB SFF 15k RPM SAS disk drive mounted in a Gen-1 carrier and supported in SFF SAS bay such as provided in the #5802/5803 I/O drawer or POWER7 system unit. Disk is formatted for 528 sectors as shipped from IBM Manufacturing. CCIN is 19A1.
Limitations: physical difference in Gen1 and Gen2 carriers prevent usage in SFF-2 bays such as used in the #5887 EXP24S I/O drawer.
- Attributes provided: 283GB of SFF (2.5-inch) SAS disk storage mounted in Gen-1 carrier.
- Attributes required: one SFF-1 drive bay
- For 8205-E6D: (#1879)
- Minimum required: 0
- Maximum allowed: 80 (Initial order maximum: 80)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 8 supported in the CEC
- System maximum of 80 with 8 in the CEC and 72 in 4 x #5802
(#1880) - 300GB 15K RPM SAS SFF Disk Drive (AIX/Linux)
(No Longer Available as of March 31, 2018)
300 GB SFF 15k RPM SAS disk drive mounted in a Gen-1 carrier and supported in SFF SAS bay such as used in the #5802/5803 I/O drawer or POWER7 system unit. Disk is formatted for 512 sectors as shipped from IBM Manufacturing. CCIN is 19A1.
Limitations: physical difference in Gen1 and Gen2 carriers prevent usage in SFF-2 bays such as used in the #5887 EXP24S I/O drawer.
- Attributes provided: 300GB of SFF (2.5-inch) SAS disk storage mounted in Gen-1 carrier.
- Attributes required: one SFF-1 drive bay
- For 8205-E6D: (#1880)
- Minimum required: 0
- Maximum allowed: 80 (Initial order maximum: 80)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 8 supported in the CEC
- System maximum of 80 with 8 in the CEC and 72 in 4 x #5802.
(#1882) - 146.8GB 10K RPM SAS SFF Disk Drive
146.8GB SFF SAS disk, in a carrier capable of providing Hot Swap support. Provides 146.8GB of storage capacity. Supports the industry standard SAS interface. Can be used only in a system designed to support the SAS SFF disk drive in a carrier.
Characteristics:
- Form Factor: SSF SAS compliant (2.5" x 15mm form factor)
- Cable included: None
- External Interface: standard SAS Dual Port
- Rotational Speed: 10,000 RPM
- Interface Speed: 3Gbs (300 MBs)
- Format: 512 Bytes/sector default, 528 Bytes/sector possible with reformat.
- Attributes provided: 146.8GB of Disk Storage mounted in a carrier
- Attributes required: one SFF SAS disk drive bay slot
- For 8205-E6D: (#1882)
- Minimum required: 0
- Maximum allowed: 80 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Maximum of 8 supported in the CEC
- System maximum of 80 with 8 in the CEC and 72 in 4 x #5802.
(#1884) - 69.7 GB 15K RPM SAS SFF Disk Drive
69.7 GB SFF SAS disk, in a carrier capable of providing Hot Swap support. Provides 69.7 GB of storage capacity. Supports the industry standard SAS interface. Can be used only in a system designed to support the SAS SFF disk drive in a carrier.
Characteristics:
- Form Factor: SFF SAS compliant (2.5" x 15mm form factor)
- Cable included: None
- External Interface: standard SAS Dual Port
- Rotational Speed: 15,000 RPM
- Interface Speed: 3Gbs (300 MBs)
- Format: 528 Bytes/sector
- Attributes provided: 69.7 GB of disk storage mounted in a carrier.
- Attributes required: One SFF SAS disk drive bay slot
- For 8205-E6D: (#1884)
- Minimum required: 0
- Maximum allowed: 80 (Initial order maximum: 0)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#1885) - 300GB 10K RPM SFF SAS Disk Drive
(No Longer Available as of July 8, 2016)
300GB SFF SAS disk, in a carrier capable of providing Hot Swap support. The disk supports the industry standard SAS interface. Systems that accept SAS SFF disk drive in a carrier accommodate this SAS disk.
Characteristics:
- Form Factor: SSF SAS compliant (2.5" x 15mm form factor)
- Cable included: None
- External Interface: standard SAS Dual Port
- Rotational Speed: 10,000 RPM
- Interface Speed: 3Gbs (300 MBs)
- Format: 512 Bytes/sector default, 528 Bytes/sector possible with reformat.
- Attributes provided: 300GB of Disk Storage mounted in a carrier
- Attributes required: one SFF SAS disk drive bay slot
- For 8205-E6D: (#1885)
- Minimum required: 0
- Maximum allowed: 80 (Initial order maximum: 80)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 8 supported in the CEC
- System maximum of 80 with 8 in the CEC and 72 in 4 x #5802.
(#1886) - 146GB 15K RPM SFF SAS Disk Drive (AIX/Linux)
(No Longer Available as of July 8, 2016)
146.8 GB SFF SAS disk, in a carrier capable of providing Hot Swap support. Provides 146.8 GB of storage capacity. Supports the industry standard SAS interface. Can be used only in a system designed to support the SAS SFF disk drive in a carrier.
Characteristics:
- Form Factor: SFF SAS compliant (2.5" x 15mm form factor)
- Cable included: None
- External Interface: standard SAS Dual Port
- Rotational Speed: 15,000 RPM
- Interface Speed: 3Gbs (300 MBs)
- Format: 512 Bytes/sector
- Attributes provided: 146.8 GB of disk storage mounted in a carrier.
- Attributes required: One SFF SAS disk drive bay slot
- For 8205-E6D: (#1886)
- Minimum required: 0
- Maximum allowed: 80 (Initial order maximum: 80)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 8 supported in the CEC
- System maximum of 80 with 8 in the CEC and 72 in 4 x #5802.
(#1887) - Quantity 150 of #1793
(No Longer Available as of August 23, 2013)
This feature ships a quantity of 150 #1793 177GB SFF-2 SSD w/ eMLC (AIX/Linux) units. The configurator may either generate this feature or allow users to select this feature as they would any other single SSD unit feature. This feature remains on the inventory records.
- Attributes provided: see feature #1793
- Attributes required: see feature #1793
- For 8205-E6D: (#1887)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 2)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1888) - 139GB 15K RPM SFF SAS Disk Drive (IBM i)
(No Longer Available as of July 8, 2016)
139 GB SFF SAS disk, in a carrier capable of providing Hot Swap support. Provides 139 GB of storage capacity. Supports the industry standard SAS interface. Can be used only in a system designed to support the SAS SFF disk drive in a carrier.
Characteristics:
- Form Factor: SFF SAS compliant (2.5" x 15mm form factor)
- Cable included: None
- External Interface: standard SAS Dual Port
- Rotational Speed: 15,000 RPM
- Interface Speed: 3Gbs (300 MBs)
- Format: 528 Bytes/sector
- Attributes provided: 139 GB of disk storage mounted in a carrier.
- Attributes required: One SFF SAS disk drive bay slot
- For 8205-E6D: (#1888)
- Minimum required: 0
- Maximum allowed: 80 (Initial order maximum: 80)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 8 supported in the CEC
- System maximum of 80 with 8 in the CEC and 72 in 4 x #5802.
(#1905) - 4 GB Single-Port Fibre Channel PCI-X 2.0 DDR Adapter
The 4 Gigabit Single-Port Fibre Channel PCI-X 2.0 DDR Adapter is a 64-bit address/data, short form factor PCI-X adapter with an LC type external fiber connector that provides single initiator capability over an optical fiber link or loop. With the use of appropriate optical fiber cabling, this adapter provides the capability for a network of high-speed local and remote located storage. The adapter will auto-negotiate for the highest data rate between adapter and an attaching device at 1 Gbps, 2 Gbps or 4 Gbps of which the device or switch is capable. Distances up to 500 meters running at 1 Gbps data rate, up to 300 meters running at 2 Gbps data rate, and 4 Gbps data rate up to 150 meters are supported between the adapter and an attaching device or switch. When used with IBM Fibre Channel storage switches supporting long-wave optics, distances up to 10 kilometers are capable running at either 1 Gbps, 2 Gbps, or 4 Gbps data rates.
The 4 Gigabit Single-Port Fibre Channel PCI-X Adapter can be used to attach devices either directly, or by means of Fibre Channel Switches. If attaching a device or switch with a SC type fiber connector(s), use of an LC-SC 50 Micron Fiber Converter Cable (#2456) or a LC-SC 62.5 Micron Fiber Converter Cable (#2459) is required.
There are two maximum quantities for High Bandwidth adapters, one for performance, and one for connectivity. Adapter performance may be limited by bandwidth constraints in a network. To maximize High Bandwidth adapter performance in the server the performance maximum quantity should not be exceeded. In applications where the end-to-end network cannot sustain high performance and or connectivity is more important than overall bandwidth performance the performance maximum quantity can be exceeded up to the connectivity maximum quantity.
Refer to the following IBM storage subsystem web page for additional supported server attachment information for IBM devices.
Consult with your IBM representative or Business Partner for additional information relative to any third party attachment.
- Attributes provided: 1 Fibre Channel
- Attributes required: 1 empty PCI or PCI-X 1.0 / 2.0 slot
- For 8205-E6D: (#1905)
- Minimum required: 0
- Maximum allowed: 48 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Maximum of 8 supported in the CEC
- System maximum of 80 with 8 in the CEC and 72 in 4 x #5802.
(#1910) - 4 GB Dual-Port Fibre Channel PCI-X 2.0 DDR Adapter
The 4 Gigabit Dual-Port Fibre Channel PCI-X 2.0 DDR Adapter is a 64-bit address/data, short form factor PCI-X adapter with an LC type external fiber connector that provides single or dual initiator capability over an optical fiber link or loop. With the use of appropriate optical fiber cabling, this adapter provides the capability for a network of high-speed local and remote located storage. The adapter will auto-negotiate for the highest data rate between adapter and an attaching device at 1 Gbps, 2 Gbps or 4 Gbps of which the device or switch is capable. Between the adapter and an attaching device or switch, the distances supported are up to: 500 meters running at 1 Gbps data rate, 300 meters running at 2 Gbps data rate, and 150 meters running at 4 Gbps data rate. When used with IBM Fibre Channel storage switches supporting long-wave optics, distances of up to 10 kilometers are capable running at either 1 Gbps, 2 Gbps, or 4 Gbps data rates.
The 4 Gb Dual-Port Fibre Channel PCI-X Adapter can be used to attach devices either directly, or by means of Fibre Channel Switches. If attaching a device or switch with a SC type fiber connector(s), use of an LC-SC 50 Micron Fiber Converter Cable (#2456) or a LC-SC 62.5 Micron Fiber Converter Cable (#2459) is required.
There are two maximum quantities for High Bandwidth adapters, one for performance, and one for connectivity. Adapter performance may be limited by bandwidth constraints in a network. To maximize High Bandwidth adapter performance in the server the performance maximum quantity should not be exceeded. In applications where the end-to-end network cannot sustain high performance and or connectivity is more important than overall bandwidth performance the performance maximum quantity can be exceeded up to the connectivity maximum quantity.
Refer to the following IBM storage subsystem web page for additional supported server attachment information for IBM devices.
Consult with your IBM representative or Business Partner for additional information relative to any third party attachment.
- Attributes provided: 2 Fibre Channel
- Attributes required: 1 empty PCI or PCI-X 2.0 slot
- For 8205-E6D: (#1910)
- Minimum required: 0
- Maximum allowed: 48 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC
- System maximum of 48 in 8 x #5796
(#1911) - 283GB 10K RPM SFF SAS Disk Drive (IBM i)
(No Longer Available as of July 8, 2016)
283 GB SFF SAS disk in a carrier capable of providing Hot Swap support. Provides 283 GB of storage capacity. Supports the industry standard SAS interface. Can be used only in a system designed to support the SAS SFF disk drive in a carrier.
- Attributes provided: 283 GB of disk storage mounted in a carrier
- Attributes required: One SFF SAS disk drive bay slot
- For 8205-E6D: (#1911)
- Minimum required: 0
- Maximum allowed: 80 (Initial order maximum: 80)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 8 supported in the CEC
- System maximum of 80 with 8 in the CEC and 72 in 4 x #5802.
(#1912) - PCI-X DDR Dual Channel Ultra320 SCSI Adapter
The PCI-X DDR Dual Channel Ultra320 SCSI Adapter (#1912) is a 64-bit 3.3-volt adapter and is an excellent solution for high- performance SCSI applications. The PCI-X Dual Channel Ultra320 SCSI Adapter provides two SCSI channels (busses), each capable of running 320 MBps (max.). Each SCSI bus can only support external attach SCSI devices.
In order to achieve an Ultra320 SCSI bus data rate of up to 320 MB per second and maintain a reasonable drive distance, the adapter utilizes Low Voltage Differential (LVD) drivers and receivers. To utilize the 320 MB per second performance, all attaching devices should also be Ultra320 LVD devices; however, if Ultra2, Ultra3, or Ultra320 devices coexist on the same bus, each device will operate at its rated speed. For lower speed single-ended (SE) devices, the SCSI bus will switch to single-ended (SE) performance and interface to all devices on that SCSI bus at the lower SE bus data rate of the device.
Two VHDCI 68-pin connectors are mounted on the adapter's end bracket allowing attachment of various LVD and SE external subsystems. A 0.3-meter converter cable, VHDCI to P, Mini-68 pin to 68-pin, (#2118) can be used with older external SE devices or subsystems to allow connection to the VHDCI connector on the PCI-X DDR Dual Channel Ultra320 SCSI Adapter.
Two external ports provide connectivity to numerous other SCSI external subsystems. Check the external subsystem sales/web pages for verification of connectivity support with this adapter.
The PCI-X Dual Channel Ultra320 SCSI Adapter (#1912) is a native boot adapter. The adapter also supports target mode.
Limitations:
- The two external ports do not support the connection to the IBM 7131-105 IBM Multi-Storage Tower Model 105.
- The Dual Channel Ultra320 SCSI nonRAID Adapter has ports that are capable at running at ultra320 SCSI speeds (up to 320 MBytes/s).
- Attributes provided: Attachment of external SCSI devices only on Power7 Servers.
- Attributes required: One available 3.3 volt PCI or PCI-X slot or PCI-X 2.0 DDR slot
- For 8205-E6D: (#1912)
- Minimum required: 0
- Maximum allowed: 48 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC
- System maximum of 48 in 8 x #5796
(#1916) - 571GB 10k RPM SAS SFF Disk Drive (IBM i)
(No Longer Available as of March 31, 2018)
571GB SFF 10k rpm SAS drive in Gen1 SFF carrier. Supported in SFF SAS bays such as provided in most POWER7 system units or the #5802/ 5803 I/O drawers. Disk is formatted for 528 byte sectors.
Limitation: can not be used in #5887 EXP24S Gen2 I/O drawer due to physical difference in Gen1 and Gen2 carriers.
- Attributes provided: 571GB of Disk Storage mounted Gen-1 carrier
- Attributes required: one SFF SAS disk drive bay slot
- For 8205-E6D: (#1916)
- Minimum required: 0
- Maximum allowed: 80 (Initial order maximum: 80)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 8 supported in the CEC
- System maximum of 80 with 8 in the CEC and 72 in 4 x #5802.
(#1917) - 146GB 15k RPM SAS SFF-2 Disk Drive (AIX/Linux)
(No Longer Available as of July 8, 2016)
146GB SFF 15k RPM SAS SFF-2 Disk Drive (AIX/Linux) mounted in Gen-2 carrier and supported in SFF SAS bays such as provided in #5887 EXP24S Gen2 I/O drawer. Disk is formatted for 512 byte sectors.
Limitation: can not be used in #5802/5803 I/O drawers due to physical difference in Gen1 and Gen2 carriers.
- Attributes provided: 146GB of Disk Storage mounted in a Gen-2 carrier
- Attributes required: One SFF SAS disk drive bay slot
- For 8205-E6D: (#1917)
- Minimum required: 0
- Maximum allowed: 336 (Initial order maximum: 250)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Not supported in the CEC
- System maximum of 336 in 14 x #5887
(#1925) - 300GB 10k RPM SAS SFF-2 Disk Drive (AIX/Linux)
(No Longer Available as of July 8, 2016)
300GB SFF 10k RPM SAS SFF-2 Disk Drive (AIX/Linux). Supported in SFF SAS bays such as provided in #5887 EXP24S Gen2 I/O drawer. Disk is formatted for 512 byte sectors.
Limitation: can not be used in #5802/5803 I/O drawers or in CEC due to physical difference in Gen1 and Gen2 carriers.
- Attributes provided: 300GB SFF disk drive mounted in a carrier
- Attributes required: One SFF Gen-2 bay
- For 8205-E6D: (#1925)
- Minimum required: 0
- Maximum allowed: 336 (Initial order maximum: 250)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Not supported in the CEC
- System maximum of 336 in 14 x #5887
(#1927) - Quantity 150 of #1948
(No Longer Available as of March 31, 2018)
This feature ships a quantity of 150 #1948 disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records.
- Attributes provided: see feature #1948
- Attributes required: see feature #1948
- For 8205-E6D: (#1927)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 2)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1929) - Quantity 150 of #1953
(No Longer Available as of March 31, 2018)
This feature ships a quantity of 150 #1953 disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records.
- Attributes provided: see feature #1953
- Attributes required: see feature #1953
- For 8205-E6D: (#1929)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 2)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1947) - 139GB 15k RPM SAS SFF-2 Disk Drive (IBM i)
(No Longer Available as of July 8, 2016)
139GB SFF 15k RPM SAS SFF-2 Disk Drive (IBM i) Supported in SFF SAS bays such as provided in #5887 EXP24S Gen2 I/O drawer. Disk is formatted for 528 byte sectors.
Limitation: can not be used in #5802/5803 I/O drawers or in CEC due to physical difference in Gen1 and Gen2 carriers.
- Attributes provided: 139GB SAS disk drive
- Attributes required: One disk bay
- For 8205-E6D: (#1947)
- Minimum required: 0
- Maximum allowed: 336 (Initial order maximum: 250)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Not supported in the CEC
- System maximum of 336 in 14 x #5887
(#1948) - 283GB 15k RPM SAS SFF-2 Disk Drive (IBM i)
(No Longer Available as of March 31, 2018)
283 GB SFF 15k RPM SAS disk drive mounted in a Gen-2 carrier and supported in SFF SAS bay such as provided in the #5887 EXP24S I/O drawer. Disk is formatted for 528 sectors as shipped from IBM Manufacturing. CCIN is 19B1.
Limitations: physical difference in Gen1 and Gen2 carriers prevent usage in SFF-1 bays such as used in the #5802/5803 I/O drawer.
- Attributes provided: 283GB of SFF (2.5-inch) SAS disk storage mounted in Gen-2 carrier.
- Attributes required: one SFF-2 drive bay
- For 8205-E6D: (#1948)
- Minimum required: 0
- Maximum allowed: 336 (Initial order maximum: 250)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Not supported in the CEC
- System maximum of 336 in 14 x #5887
(#1953) - 300GB 15k RPM SAS SFF-2 Disk Drive (AIX/Linux)
(No Longer Available as of March 31, 2018)
300 GB SFF 15k RPM SAS disk drive mounted in a Gen-2 carrier and supported in SFF SAS bay such as used in the #5887 EXP24S I/O drawer. Disk is formatted for 512 sectors as shipped from IBM Manufacturing. CCIN is 19B1.
Limitations: physical difference in Gen1 and Gen2 carriers prevent usage in SFF-1 bays such as used in the #5802/5803 I/O drawer
- Attributes provided: 300GB of SFF (2.5-inch) SAS disk storage mounted in Gen-2 carrier.
- Attributes required: one SFF-2 drive bay
- For 8205-E6D: (#1953)
- Minimum required: 0
- Maximum allowed: 336 (Initial order maximum: 250)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Not supported in the CEC
- System maximum of 336 in 14 x #5887
(#1954) - 4-Port 10/100/1000 Base-TX PCI-X Adapter
The 4-Port 10/100/1000 Base -TX PCI-X adapter is a full height PCI-X 1.0a Ethernet adapter which supports four Gigabit ports on a single adapter, delivers increased bandwidth for slot-constrained servers, and is designed to provide high connectivity and reliability using two integrated, dual-port Gigabit Ethernet controllers.
- Four RJ-45 ports
- 3.3 volts, 64-bit 133 MHz with 64-bit Bus Mastering on the PCI-X bus
- IEEE 802.3ab 1000Base-T compliant
- IEEE 802.3u 100Base-T compliant
- IEEE 802.3 10Base-T compliant
- 802.1q VLAN tagging
- Interrupt Moderation
- TCP Segmentation offload and encapsulation in hardware
- Checksum offloading of IP, TCP, and UDP frame
- Increased connectivity while significantly reducing CPU utilization
- Two LED adapter status indicators per port for link activity and speed
- NIM is supported on all 4 ports
- RoHS compliant
Limit Full bandwidth performance may not be achieved with more than one adapter per PCI Host Bridge (PHB) or more than one CPU.
- Attributes provided: Four 10/100/1000 RJ-45 ports
- Attributes required: One available PCI-X card slot
- For 8205-E6D: (#1954)
- Minimum required: 0
- Maximum allowed: 48 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC
- System maximum of 48 in 8 x #5796
(#1956) - 283GB 10k RPM SAS SFF-2 Disk Drive (IBM i)
(No Longer Available as of July 8, 2016)
283GB SFF 10k RPM SAS SFF-2 Disk Drive (AIX/Linux. Supported in SFF SAS bays such as provided in #5887 EXP24S Gen2 I/O drawer. Disk is formatted for 528 byte sectors.
Limitation: can not be used in #5802/5803 I/O drawers or CEC due to physical difference in Gen1 and Gen2 carriers.
- Attributes provided: 283GB SAS disk drive
- Attributes required: one drive bay
- For 8205-E6D: (#1956)
- Minimum required: 0
- Maximum allowed: 336 (Initial order maximum: 250)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Not supported in the CEC
- System maximum of 336 in 14 x #5887
(#1958) - Quantity 150 of #1794
(No Longer Available as of August 23, 2013)
This feature ships a quantity of 150 #1794 177GB SSF-2 SSD w/ eMLC (IBM i) units. The configurator may either generate this feature or allow users to select this feature as they would any other single SSD unit feature. This feature remains on the inventory records.
- Attributes provided: see feature #1794
- Attributes required: see feature #1794
- For 8205-E6D: (#1958)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 2)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#1962) - 571GB 10k RPM SAS SFF-2 Disk Drive (IBM i)
(No Longer Available as of March 31, 2018)
571GB SFF 10k rpm SAS drive in gen 1 SFF carrier. Supported in SFF SAS bays such as provided in #5887 EXP24S Gen2 I/O drawer. Disk is formatted for 528 byte sectors.
Limitation: can not be used in #5802/5803 I/O drawers or in CEC bays due to physical difference in Gen1 and Gen2 carriers.
- Attributes provided: 571GB of Disk Storage mounted in a Gen2 carrier
- Attributes required: one SFF SAS disk drive bay
- For 8205-E6D: (#1962)
- Minimum required: 0
- Maximum allowed: 336 (Initial order maximum: 250)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Not supported in the CEC
- System maximum of 336 in 14 x #5887
(#1964) - 600GB 10k RPM SAS SFF-2 Disk Drive (AIX/Linux)
(No Longer Available as of March 31, 2018)
600GB SFF 10k rpm SAS drive in Gen-2 carrier. Supported in SFF SAS bays such as provided in #5887 EXP24S Gen2 I/O drawer. Disk is formatted for 512 byte sectors.
Limitation: can not be used in #5802/5803 I/O drawers or in CEC SFF bays due to physical difference in Gen1 and Gen2 carriers.
- Attributes provided: 600GB of Disk Storage mounted in a Gen2 carrier
- Attributes required: one SFF (SFF-2) SAS GEN2 drive bay
- For 8205-E6D: (#1964)
- Minimum required: 0
- Maximum allowed: 336 (Initial order maximum: 250)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Not supported in the CEC
- System maximum of 336 in 14 x #5887
(#1977) - 2 Gigabit Fibre Channel PCI-X Adapter
The 2 Gigabit Fibre Channel PCI-X Adapter is a 64-bit address/data, short form factor PCI-X adapter with an LC type external fiber connector that provides single or dual initiator capability over an optical fiber link or loop. With the use of appropriate optical fiber cabling, this adapter provides the capability for a network of high speed local and remote located storage. The 2 Gigabit Fibre Channel PCI-X Adapter will auto-negotiate for the highest data rate (either 1 Gbps or 2 Gbps) of which the device or switch is capable. Distances of up to 500 meters running at 1 Gbps data rate and up to 300 meters running at 2 Gbps data rate are supported between the adapter and an attaching device or switch. When used with IBM supported Fibre Channel storage switches supporting long-wave optics, distances of up to 10 kilometers are capable running at either 1 Gps or 2 Gps data rates.
The 2 Gigabit Fibre Channel PCI-X Adapter can be used to attach devices either directly, or by means of Fibre Channel Switches. If attaching a device or switch with a SC type fiber connector(s), use of an LC-SC 50 Micron Fiber Converter Cable (#2456) or a LC-SC 62.5 Micron Fiber Converter Cable (#2459) is required.
Refer to the following IBM storage subsystem web page for additional supported server attachment information for IBM devices.
Consult with your IBM representative or Business Partner for additional information relative to any third party attachment.
- Attributes provided: 1 Fibre Channel/FC-AL interface
- Attributes required: 1 empty PCI or PCI-X slot
- For 8205-E6D: (#1977)
- Minimum required: 0
- Maximum allowed: 48 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC
- System maximum of 48 in 8 x #5796
(#1978) - IBM Gigabit Ethernet-SX PCI-X Adapter
The IBM Gigabit Ethernet-SX PCI-X Adapter provides a 1 Gbps (1000 Base-SX) full-duplex Ethernet LAN connection with throughput on a standard shortwave multimode optical cable which conforms to the IEEE 802.3z standard. The adapter supports distances of 260m for 62.5 micron Multi Mode Fiber (MMF) and 550m for 50.0 micron MMF. AIX Network Install Manager (NIM) boot capability is supported with this adapter.
Note: For optimum performance, the adapter should be placed in a 64 bit PCI-X card slot.
Note: The IBM Gigabit Ethernet-SX PCI-X Adapter (#1978) incorporates an LC type connector on the card. This new, smaller form factor connector is being used by the industry for the next generation of fiber optic networks. If connecting into an older, existing SC type connector network, an LC-SC 62.5 Micron Fiber Converter Cable (#2459) or LC-SC 50 Micron Fiber Converter Cable (#2456) is required.
Limitation: Half Duplex (HDX) mode is not supported.
- Attributes provided: One full-duplex 1000Base-SX fiber connection to a Gigabit Ethernet LAN.
- Attributes required: One available PCI or PCI-X card slot
- For 8205-E6D: (#1978)
- Minimum required: 0
- Maximum allowed: 48 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC
- System maximum of 48 in 8 x #5796
(#1979) - IBM 10/100/1000 Base-TX Ethernet PCI-X Adapter
The IBM 10/100/1000 Base-TX Ethernet PCI-X Adapter is a Full Duplex Gigabit Ethernet adapter designed with highly integrated components. This adapter can be configured to run at 10, 100, or 1000 Mbps data rates. The adapter interfaces to the system via the PCI-X bus and connects to the network using a 4-pair CAT-5 Unshielded Twisted Pair (UTP) cable for distances of up to 100m. AIX Network Install Manager (NIM) boot capability is supported with this adapter. The adapter conforms to the IEEE 802.3ab 1000Base-T standard. The adapter also supports jumbo frames when running at the 1000 Mbps speed.
Note: For optimum performance, adapter should be placed in a 64 bit PCI-X card slot.
Limitations: The 1000 Mbps speed is not supported in Half Duplex (HDX) mode.
- Attributes provided: One full-duplex 10/100/1000Base-TX UTP connection to a Gigabit Ethernet LAN.
- Attributes required: One available PCI or PCI-X card slot
- For 8205-E6D: (#1979)
- Minimum required: 0
- Maximum allowed: 48 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC
- System maximum of 48 in 8 x #5796
(#1980) - POWER GXT135P Graphics Accelerator with Digital Support
The POWER GXT135P is a versatile, low-priced 2D graphics accelerator for RS/6000 workstations and pSeries servers. It can be configured to operate in either 8-bit or 24-bit color modes. This adapter supports both analog and digital monitors. Its predecessor, Feature Number 2848, supported only analog monitors.
- Hardware Description
- 128-bit graphics processor
- 8-bit CLUT or 24-bit true color
- 16 MB SDRAM
- 32-bit PCI interface
- Universal PCI (5.0v or 3.3v)
- 1 hardware color map
- Features Supported
- Up to approximately 16.7 million colors
- Rectangular clipping
- 2 analog monitor outputs at up to 1280 x 1024 resolution
- 1 analog monitor output at up to 2048 x 1536 resolution
- 1 digital monitor output at up to 1600 x 1200 resolution
- 60 to 85 Hz refresh rates (ISO 9241, Part 3)
- APIs Supported
- X-Windows and Motif
- UMS 2.3.0 (no hardware scaling)
- Attributes provided: 2D Graphics
- Attributes required: 1 PCI slot
- For 8205-E6D: (#1980)
- Minimum required: 0
- Maximum allowed: 8 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC.
- System maximum of 8.
(#1983) - IBM 2-Port 10/100/1000 Base-TX Ethernet PCI-X Adapter
The IBM 2-Port 10/100/1000 Base-TX Ethernet PCI-X Adapter is a Full Duplex, dual ported, Gigabit Ethernet adapter designed with highly integrated components. This adapter can be configured to run each port at 10, 100, or 1000 Mbps data rates. The adapter interfaces to the system via a PCI or PCI-X bus and connects to a network using a 4-pair CAT-5 Unshielded Twisted Pair (UTP) cable for distances of up to 100m. AIX Network Install Manager (NIM) boot capability is supported with this adapter. The adapter conforms to the IEEE 802.3ab 1000Base-T standard. The adapter also supports jumbo frames when running at the 1000 Mbps speed.
A function called 'Large Send' or sometimes known as TCP Segmentation is also provided by this adapter. This function offloads the TCP segmentation operation from the AIX IP layer to the adapter for outgoing (transmit side) TCP segments. Another function known as "Checksum Offload" which offloads the TCP/UDP Checksum Operation or workload from the CPU to the adapter is also provided.
The IBM 2-Port 10/100/1000 Base-TX Ethernet PCI-X Adapter (#1983) should be considered where maximum port density is required per I/O card slot. For a suggested maximum number of adapters taking performance into consideration, refer to the RS/6000 & pSeries PCI Adapter Placement Reference SA38-0538. If card slots are not the limiting factor and maximum throughput is required, the single port IBM 10/100/1000 Base-TX Ethernet PCI-X Adapter (#1979) is the preferred solution.
Note: For optimum performance, the adapter should be placed in a 64 bit PCI-X card slot whenever possible.
Limitations: The 1000 Mbps speed is not supported in Half Duplex (HDX) mode.
- Attributes provided: Two full-duplex 10/100/1000Base-TX UTP connections to Gigabit Ethernet LAN(s).
- Attributes required: One available PCI or PCI-X card slot
- For 8205-E6D: (#1983)
- Minimum required: 0
- Maximum allowed: 48 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC
- System maximum of 48 in 8 x #5796
(#1986) - 1 Gigabit iSCSI TOE PCI-X on Copper Media Adapter
The 1 Gigabit iSCSI TOE PCI-X adapter encapsulates SCSI Commands and data into TCP and transports them over the Ethernet via IP packets. The adapter operates as an iSCSI TOE (TCP/IP Offload Engine). This offload function eliminates host protocol processing and reduces CPU interrupts. Adapter uses RJ45 Gigabit Ethernet connector.
- Attributes provided: Offload of host protocol processing
- Attributes required: Available PCI-X Slot
- For 8205-E6D: (#1986)
- Minimum required: 0
- Maximum allowed: 48 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC
- System maximum of 48 in 8 x #5796
(#1987) - 1 Gigabit iSCSI TOE PCI-X on Optical Media Adapter
The 1 Gigabit iSCSI TOE PCI-X adapter encapsulates SCSI Commands and data into TCP and transports them over the Ethernet via IP packets. The adapter operates as an iSCSI TOE (TCP/IP Offload Engine). This offload function eliminates host protocol processing and reduces CPU interrupts. Adapter uses Small form factor LC type fiber optic connector.
- Attributes provided: Offload of host protocol processing
- Attributes required: Available PCI-X Slot
- For 8205-E6D: (#1987)
- Minimum required: 0
- Maximum allowed: 48 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC
- System maximum of 48 in 8 x #5796
(#1995) - 177GB SSD Module with eMLC (AIX/Linux)
(No Longer Available as of August 23, 2013)
The Solid State Drive (SSD) Module is a compact storage device about the size of a fat credit card which is placed in a socket of the #2053, #2054 or #2055 PCIe RAID & SAS Adapter. It is shipped from IBM with RAID formatting to provide 177 GB capacity for AIX/IBM i/Linux. Reformatted as JBOD under AIX/Linux provides 200 GB capacity but drops the extra protection RAID formatting provides.
Feature #1995 and #1996 are physically identical with CCIN = 58B2, but two features are used to allow IBM configurator tools to understand usage by either AIX/Linux or IBM i. #1995 indicates AIX/ Linux usage.
The #1995/1996 uses Enterprise Multi-Level Cell (eMLC) technology, to provide extremely reliable, cost effective, dense SSD storage. The 1.8" SSD module contains a NAND flash controller that provides a 3Gbit/sec SATA interface. Parallel access to 16 flash sites allows overlapped, multi-block access to complete data transfer requests rapidly. An embedded super capacitor ensures data integrity during power fail scenarios.
- Attributes provided: 177GB (RAID) or 200GB(JBOD) formatted SSD Module
- Attributes required: Available socket on the following controllers #2053, #2054 or #2055 PCIe RAID & SAS Adapter. Limit is 1, 2, 3 or 4 on each controller.
- For 8205-E6D: (#1995)
- Minimum required: 0
- Maximum allowed: 96 (Initial order maximum: 96)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
Note:
- Requires available socket on a #2053, #2054 or #2055.
- Max 4 per PCIe RAID & SSD SAS Adapter
- Minimum of 1, 2, 3, or 4 is required
- Supports VIOS attachment version 2.2 or later
(#1996) - 177GB SSD Module with eMLC (IBM i)
(No Longer Available as of May 13, 2016)
The Solid State Drive (SSD) Module is a compact storage device about the size of a fat credit card which is placed in a socket of the #2053, #2054 or #2055 PCIe RAID & SAS Adapter. It is shipped from IBM with RAID formatting to provide 177 GB capacity for AIX/IBM i/Linux. Reformatted as JBOD under AIX/Linux provides 200 GB capacity but drops the extra protection RAID formatting provides.
Feature #1995 and #1996 are physically identical with CCIN = 58B2, but two features are used to allow IBM configurator tools to understand usage by either AIX/Linux or IBM i. #1995 indicates AIX/ Linux usage.
The #1995/1996 uses Enterprise Multi-Level Cell (eMLC) technology, to provide extremely reliable, cost effective, dense SSD storage. The 1.8" SSD module contains a NAND flash controller that provides a 3Gbit/sec SATA interface. Parallel access to 16 flash sites allows overlapped, multi-block access to complete data transfer requests rapidly. An embedded super capacitor ensures data integrity during power fail scenarios.
- Attributes provided: 177GB formatted SSD Module
- Attributes required: Available socket on the following controllers #2053, #2054 or #2055 PCIe RAID & SAS Adapter. Limit is 1, 2, 3 or 4 on each controller.
- For 8205-E6D: (#1996)
- Minimum required: 0
- Maximum allowed: 96 (Initial order maximum: 96)
- OS level required:
- IBM i 7.1 supported
- IBM i 6.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
Note:
- Requires available socket on a #2053, #2054 or #2055.
- Max 4 per PCIe RAID & SSD SAS Adapter
- Minimum of 1, 2, 3, or 4 is required
- Supports VIOS attachment version 2.2 or later
(#2053) - PCIe LP RAID & SSD SAS Adapter 3Gb
(No Longer Available as of May 13, 2016)
PCIe RAID & SSD SAS Adapter 3GB is a double-wide, short, PCIE-8x, Solid State Drive (SSD) module controller. Each adapter has four slots and each slot can hold a SSD feature modules. Two feature SDD modules are available. #1995 for AIX/Linux and #1996 for IBM i. Initial orders require a minimum of 1 SSD feature module and can be increased to 2, 3, or 4 modules. SSD modules must be either all #1995 or all #1996. There are no external ports and no cables of any type attach/connect to PCIe RAID & SSD SAS Adapter.
Note: On certain IBM Power and the IBM PowerLInux servers a maximum of two 1995/1996 modules per #2053 are allowed. To have more than two 1995/1996 modules per #2053 RPQ 8A1859 can be used.
The PCIe adapter provides RAID 0, 5 or 6 is for AIX and Linux for SSD modules on the PCIe adapter. It provides RAID 5 or 6 for IBM i. Mirroring is supported on all OS types. If RAID 0 is used, the modules must be mirrored. The PCIe RAID & SSD SAS Adapter does not provide write cache.
SSD modules can not be added/removed/replaced until the PCIe adapter is removed from the PCIe slot.
Though the electronics are identical and there is one CCIN (57CD), there are three feature codes for the adapter: #2053 Low Profile non- cassette for use in CECs with low profile slots, #2054 non-cassette with tail stock for a full regular height PCIe slot, and #2055 with Blind Swap Cassette for use in #5802 or #5877 PCIe I/ O drawers. There are also #4367 and #4377 which are packages shipping five PCIe adapters and twenty SSD modules.
- Attributes provided: PCIe RAID & SSD SAS Adapter 3Gb with 4 SSD slots
- Attributes required: Two adjacent PCIe slots. Each #2053 requires 1, 2, 3 or 4 SSDs, either #1995 or #1996
- For 8205-E6D: (#2053)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 2)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 7.1 supported
- IBM i 6.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note: VIOS attachment requires, version 2.2 or later
(#2054) - PCIe RAID & SSD SAS Adapter 3Gb
(No Longer Available as of May 13, 2016)
PCIe RAID & SSD SAS Adapter 3GB is a double-wide, short, PCIE-8x, Solid State Drive (SSD) module controller. Each adapter has four slots and each slot can hold a SSD feature modules. Two feature SDD modules are available. #1995 for AIX/Linux and #1996 for IBM i Initial orders require a minimum of 1 SSD feature module and can be increased to 2 or 4 modules. 3 SSD modules on one adapter is not supported. SSD modules must be either all #1995 or all #1996. There are no external ports and no cables of any type attach/connect to PCIe RAID & SSD SAS Adapter.
The PCIe adapter provides RAID 0, 5 or 6 is for AIX and Linux for SSD modules on the PCIe adapter. It provides RAID 5 or 6 for IBM i. Mirroring is supported on all OS types. If RAID 0 is used, the modules must be mirrored. The PCIe RAID & SSD SAS Adapter does not provide write cache.
SSD modules can not be added/removed/replaced until the PCIe adapter is removed from the PCIe slot.
Though the electronics are identical and there is one CCIN (57CD), there are three feature codes for the adapter: #2053 Low Profile non- cassette for use in CECs with low profile slots, #2054 non-cassette with tail stock for a full regular height PCIe slot, and #2055 with Blind Swap Cassette for use in #5802 or #5877 PCIe I/ O drawers. There are also #4367 and #4377 which are packages shipping five PCIe adapters and twenty SSD modules.
- Attributes provided: PCIe RAID & SSD SAS Adapter 3Gb with 4 SSD slots
- Attributes required: Two adjacent PCIe slots, each #2053 requires 1, 2 or 4 SSD #1995 or #1996
- For 8205-E6D: (#2054)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 2)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 7.1 supported
- IBM i 6.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note: VIOS attachment requires, version 2.2 or later
(#2055) - PCIe RAID & SSD SAS Adapter 3Gb w/ Blind Swap Cassette
(No Longer Available as of May 13, 2016)
PCIe RAID & SSD SAS Adapter 3GB is a double-wide, short, PCIE-8x, Solid State Drive (SSD) module controller. Each adapter has four slots and each slot can hold a SSD feature modules. Two feature SDD modules are available. #1995 for AIX/Linux and #1996 for IBM i Initial orders require a minimum of 1 SSD feature module and can be increased to 2 or 4 modules. 3 SSD modules on one adapter is not supported. SSD modules must be either all #1995 or all #1996. There are no external ports and no cables of any type attach/connect to PCIe RAID & SSD SAS Adapter.
The PCIe adapter provides RAID 0, 5 or 6 is for AIX and Linux for SSD modules on the PCIe adapter. It provides RAID 5 or 6 for IBM i. Mirroring is supported on all OS types. If RAID 0 is used, the modules must be mirrored. The PCIe RAID & SSD SAS Adapter does not provide write cache.
SSD modules can not be added/removed/replaced until the PCIe adapter is removed from the PCIe slot.
Though the electronics are identical and there is one CCIN (57CD), there are three feature codes for the adapter: #2053 Low Profile non- cassette for use in CECs with low profile slots, #2054 non-cassette with tail stock for a full regular height PCIe slot, and #2055 with Blind Swap Cassette for use in #5802 or #5877 PCIe I/ O drawers. There are also #4367 and #4377 which are packages shipping five PCIe adapters and twenty SSD modules.
- Attributes provided: PCIe RAID & SSD SAS Adapter 3Gb with 4 SSD slots
- Attributes required: Two adjacent PCIe slots, each #2055 requires 1, 2 or 4 SSD #1995 or #1996
- For 8205-E6D: (#2055)
- Minimum required: 0
- Maximum allowed: 20 (Initial order maximum: 20)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 7.1 supported
- IBM i 6.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note: VIOS attachment requires, version 2.2 or later
(#2118) - Converter Cable, VHDCI to P, Mini-68 pin to 68 pin, 0.3M
0.3M 16-bit SCSI cable used to convert from a Mini-68 pin VHDCI connector to a 68-pin P style connector. Cable has male Mini-68 pin VHDCI connector on one end and a female 68 pin P style connector on the other. Length = 0.3 meters.
- Attributes provided: Attachment of supported external sub-system to integrated SCSI port or SCSI adapter with VHDCI Mini-68 pin connector.
- Attributes required: None
- For 8205-E6D: (#2118)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#2145) - Primary OS - IBM i
Indicates clients intend to use the IBM i operating system on the primary system partition. This feature is used as a Manufacturing Routing indicator and does not deliver parts, software or services.
- Attributes provided: None
- Attributes required: Indicates clients intend to use the IBM i operating system on the primary system partition.
- For 8205-E6D: (#2145)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 1)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#2146) - Primary OS - AIX
Indicates clients intend to use the AIX operating system on the primary system partition. This feature is used as a Manufacturing Routing indicator and does not deliver parts, software or services.
- Attributes provided: None
- Attributes required: Indicates clients intend to use the AIX operating system on the primary system partition.
- For 8205-E6D: (#2146)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 1)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#2147) - Primary OS - Linux
Indicates clients intend to use the Linux operating system on the primary system partition. This feature is used as a Manufacturing Routing indicator and does not deliver parts, software or services.
- Attributes provided: None
- Attributes required: Indicates clients intend to use the Linux operating system on the primary system partition.
- For 8205-E6D: (#2147)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 1)
- OS level required:
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#2319) - Factory Deconfiguration of 1-core
(No Longer Available as of November 30, 2015)
Factory deconfiguration of 1 processor core to assist with optimization of software licensing.
The maximum number of this feature that can be ordered is one less than the number of cores on the system, e.g. 3 for a 4-core system, 7 for an 8-core system, 15 for a 16-core system, and 31 for a 32-core system.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#2319)
- Minimum required: 0
- Maximum allowed: 15 (Initial order maximum: 15)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 7.1 supported
- IBM i 6.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#2456) - 2M LC-SC 50 Micron Fiber Converter Cable
The 50 micron fiber cable is used to convert from LC type to SC type connectors. The 2 meter cable has a male LC type connector on one end and a female SC type connector on the other.
- Attributes provided: Cable with (1X) LC type plug and (1X) SC type receptacle
- Attributes required: None
- For 8205-E6D: (#2456)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#2459) - 2M LC-SC 62.5 Micron Fiber Converter Cable
The 62.5 micron fiber cable is used to convert from LC type to SC type connectors. The 2 meter cable has a male LC type connector on one end and a female SC type connector on the other.
- Attributes provided: Cable with (1X) LC type plug and (1X) SC type receptacle
- Attributes required: None
- For 8205-E6D: (#2459)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#2728) - 4 port USB PCIe Adapter
(No Longer Available as of March 31, 2018)
The PCI-Express 4 port USB adapter provides support for USB devices. In applications that require the use of an USB extension cable, use one FC 4256 per port.
- Attributes provided: Connectivity with USB 1.0 - 2.0 capable devices
- Attributes required: One available PCI-Express slot
- For 8205-E6D: (#2728)
- Minimum required: 0
- Maximum allowed: 8 (Initial order maximum: 8)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 5 supported in the CEC.
- System maximum of 8 with 5 in the CEC and 3 in 4 x #5802/#5877.
(#2738) - 2-Port USB PCI Adapter
The 2 Port USB PCI Adapter is a USB 2.0 capable adapter that provides for the connection of one USB keyboard and mouse.
Limitation: Limited to USB 1.1 support with AIX
- Attributes provided: USB Keyboard/Mouse Attachment
- Attributes required: One available PCI slot
- For 8205-E6D: (#2738)
- Minimum required: 0
- Maximum allowed: 48 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC
- System maximum of 48 in 8 x #5796
(#2849) - POWER GXT135P Graphics Accelerator with Digital Support
The POWER GXT135P is a versatile, low-priced 2D graphics accelerator for Power servers. It can be configured to operate in either 8-bit or 24-bit color modes. This adapter supports both analog and digital monitors. Its predecessor, Feature Number 2848, supported only analog monitors.
- Hardware Description
- 128-bit graphics processor
- 8-bit CLUT or 24-bit true color
- 16 MB SDRAM
- 32-bit PCI interface
- Universal PCI (5.0v or 3.3v)
- 1 hardware color map
- Features Supported
- Up to approximately 16.7 million colors
- Rectangular clipping
- 2 analog monitor outputs at up to 1280 x 1024 resolution
- 1 analog monitor output at up to 2048 x 1536 resolution
- 1 digital monitor output at up to 1600 x 1200 resolution
- 60 to 85 Hz refresh rates (ISO 9241, Part 3)
- APIs Supported
- X-Windows and Motif
- UMS 2.3.0 (no hardware scaling)
- Software Requirements
- The total number of Graphics Adapters in any one partition may not exceed four.
- Attributes provided: 2D Graphics
- Attributes required: 1 PCI slot
- For 8205-E6D: (#2849)
- Minimum required: 0
- Maximum allowed: 8 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC.
- System maximum of 8.
(#2861) - ARTIC960Hx 4-Port EIA-232 Cable
- Attributes provided: 4-port EIA-232 cable for (#2947)
- Attributes required: One #2947 adapter
- For 8205-E6D: (#2861)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#2863) - ARTIC960Hx 4-Port X.21 Cable
- Attributes provided: 4-port X.21 cable for (#2947)
- Attributes required: One #2947 adapter
- For 8205-E6D: (#2863)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#2864) - ARTIC960Hx 4-Port V.35 (DTE) Cable
- Attributes provided: 4-port X.35 (DTE) cable for (#2947)
- Attributes required: One #2947 adapter
- For 8205-E6D: (#2864)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#2893) - PCIe 2-Line WAN w/Modem
(No Longer Available as of July 11, 2014 except for Japan it is July 11, 2015)
The #2893 is a 2-line/port WAN w/modem PCIe adapter. This feature is the non-CIM (Complex Impedance Matching) version offered in all countries except Australia and New Zealand.
Port 0 is the modem port and supports V.92 56K Async PPP, V.92 data modem, V.44 data compression, V.34 FAX modem and FAX functions, such as ECM and 2D/1D conversion.
Port 0 does not provide Sync modem capabilities (SDLC and Sync PPP). Port 1 is the RVX port and supports multiple communications protocols, including synchronous operations.
Select one of the following cables to attach to port 0(modem port):
- #1010 Modem Cable - Austria
- #1011 Modem Cable - Belgium
- #1012 Modem Cable - Africa
- #1013 Modem Cable - Israel (supported only, not orderable)
- #1014 Modem Cable - Italy
- #1015 Modem Cable - France
- #1016 Modem Cable - Germany
- #1017 Modem Cable - UK
- #1018 Modem Cable - Iceland/Sweden
- #1020 Modem Cable - HK/NZ
- #1021 Modem Cable - Fin/Nor
- #1022 Modem Cable - Netherlands
- #1023 Modem Cable - Swiss
- #1024 Modem Cable - Denmark
- #1025 Modem Cable - US/Canada
Select one of the following cables to attach to port 1(RVX port):
- #0348 - V.24/EIA232 20-Ft PCI Cable
- #0353 - V.35 20-Ft PCI Cable
- #0359 - X.21 20-Ft PCI Cable
- #0367 - Operations Console PCI Cable (ships with a 25 pin to 9 pin
adapter)
Multiple #0367 cables can be ordered but only one per #2893) to serve as consoles for secondary partitions when Logical Partitioning is utilized. ECS is supported from both the modem port, and the RVX port.
The following cable is required to support ECS from the RVX port:
- #0348 - V.24/EIA232 20-Ft PCI Cable
The #2893 does not support the remote ring indicate function.
- Attributes provided: One PCIe slot
- Attributes required: Modem
- For 8205-E6D: (#2893)
- Minimum required: 0
- Maximum allowed: 44 (Initial order maximum: 44)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Maximum of 5 supported in the CEC.
- System maximum of 45 with 5 in the CEC and 40 in 4 x #5802/#5877.
(#2934) - 3M Asynchronous Terminal/Printer Cable EIA-232
The Asynchronous Printer/Terminal Cable is used for attaching printers, plotters, and terminals that support the EIA-232 standard to any asynchronous adapter. This cable is the equivalent of the combination of FC 2936 (modem cable) and FC 2937 (printer/terminal interposer) and replaces this method of printer/terminal attachment.
This cable is 3m (9.8 feet) long, uses DB25 connectors and is supported on all RS/6000 systems using any asynchronous ports.
- Attributes provided: EIA232 device attachment capability
- Attributes required: Any Asynchronous port
- For 8205-E6D: (#2934)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#2936) - Asynchronous Cable EIA-232/V.24 3M
Used to attach a modem to the standard I/O ports with the 10-pin to 25-pin converter cable (#3925), 8-port Cable Assembly, 16-Port Cable Assembly. The cable is 3 meters (9.8 feet) in length.
- Attributes provided: Modem attachment to async or serial port
- Attributes required: Async or serial port
- For 8205-E6D: (#2936)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#2943) - 8-Port Asynchronous Adapter EIA-232/RS-422, PCI bus
For connection of up to 8 asynchronous EIA-232 or RS-422 devices. All eight ports are software programmable to support either EIA-232E or RS-422A protocols, at up to 230K baud.
- Attributes provided: 8 Async ports
- Attributes required: One PCI slot
- For 8205-E6D: (#2943)
- Minimum required: 0
- Maximum allowed: 32 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC.
- System maximum of 32.
(#2947) - IBM ARTIC960Hx 4-Port Multiprotocol PCI Adapter
The IBM ARTIC960Hx 4-Port Selectable PCI Adapter (#2947) is a one- slot, standard length, 32-bit PCI card. The adapter provides 4-Ports of: EIA-232, EIA530, RS-449, X.21, or V.35. Each port will support speeds of up 2.0M bps. Software support is provided by ARTIC960 Support for AIX Developer's Kit.
- Attributes provided: One to four WAN connections at up to 2.0Mbps
- Attributes required: One full length 32-bit PCI slot
- For 8205-E6D: (#2947)
- Minimum required: 0
- Maximum allowed: 48 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC
- System maximum of 48 in 8 x #5796
(#2951) - Cable, V.24 / EIA-232
V.24 cable for use with #2962 - 2-Port Multiprotocol Adapter. Maximum of two cables per #2962.
- Attributes provided: V.24 Cable
- Attributes required: #2962 Adapter
- For 8205-E6D: (#2951)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#2952) - Cable, V.35
V.35 cable for use with #2962 - 2-Port Multiprotocol Adapter. Maximum of two cables per #2962.
- Attributes provided: V.35 Cable
- Attributes required: #2962 Adapter
- For 8205-E6D: (#2952)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#2953) - Cable, V.36 / EIA-499
V.36/EIA-499 cable for use with #2962 - 2-Port Multiprotocol Adapter. Maximum of two cables per #2962.
- Attributes provided: V.36 Cable
- Attributes required: #2962 Adapter
- For 8205-E6D: (#2953)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#2954) - Cable, X.21
X.21 cable for use with #2962 - 2-Port Multiprotocol Adapter. Maximum of two cables per #2962.
- Attributes provided: X.21 Cable
- Attributes required: #2962 Adapter
- For 8205-E6D: (#2954)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#2962) - 2-Port Multiprotocol PCI Adapter
This adapter provides high-speed connections between stand-alone system units on a WAN. To access WAN lines, the 2-Port Multiprotocol PCI Adapter connects via external communications equipment including Channel Service Units (CSU), Data Service Units (DSU), or through synchronous modems.
This adapter together with IBM AIXlink/X.25 provides a two-port connection to X.25 packet switched networks. IBM AIXlink/X.25 is a separately orderable LPP (5696-926).
2-Port Multiprotocol PCI Adapter with an appropriate cable is compatible with:
- X.21 DCE - Using 2-Port Cable, X.21 (#2954)
- CCITT X.21 Signalling
- CCITT V.11 Electrical
- CCITT X.27 Electrical
- EIA-422-A Electrical
- ISO 4903 Connector for DCE side of an X.21 VHSI Modem Cable
- V.24 DCE - Using 2-Port Cable, V.24/EIA-232 (#2951)
- CCITT V.24 Signalling
- CCITT V.28 Electrical
- CCITT X.21bis Electrical and Signalling
- EIA-232-C Electrical and Signalling
- ISO 2110 Connector for DCE side of an V.24 VHSI Modem Cable
- V.35 DCE - Using 2-Port Cable, V.35 (#2952)
- CCITT V.35 Some signals for signalling
- CCITT V.28 Some signals for electrical and signalling
- ISO 2593 Connector for DCE side of an V.35 VHSI Modem Cable
- V.36 DCE - Using 2-Port Cable, V.36/EIA-449 (#2953)
- CCITT V.10 Electrical
- CCITT V.11 Electrical
- Attributes provided: Two high speed WAN connections
- Attributes required: One PCI slot
- For 8205-E6D: (#2962)
- Minimum required: 0
- Maximum allowed: 48 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC.
- System maximum of 48 with 8 x #5796.
(#3124) - Serial-to-Serial Port Cable for Drawer/Drawer- 3.7M
This 3.7 meter cable is available to provide a null-modem connection between the serial ports of two system drawers that are mounted within the same rack. The cable provides a DB25 female connector at each end.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#3124)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#3125) - Serial-to-Serial Port Cable for Rack/Rack- 8M
This 8 meter cable is available to provide a null-modem connection between the serial ports of two system drawers that are mounted in separate racks. The cable provides a DB25 female connector at each end.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#3125)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#3287) - 1m, (3.3-ft) IB 40G Copper Cable QSFP/QSFP
This 1 meter (3.3 foot) copper cable provides a high bandwidth connection up to 40 Gb/s (Quad Data Rate). Both ends of the cable have a QFSP connector. The cable connectors can be described as QSFP+/QSFP+ as well as QSFP/QSFP. Usage examples include a) connecting a PCIe2 InfiniBand QDR Adapter to a QDR IB switch or b) connecting two IBM Rack Switches together using QSFP+ ports.
- Attributes provided: 1 meter Quad Data Rate InfiniBand Copper Cable, QSFP/QSFP
- Attributes required: QDR InfiniBand QSFP port
- For 8205-E6D: (#3287)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#3288) - 3m, (9.8-ft.) IB 40G Copper Cable QSFP/QSFP
This 3 meter (9.8 foot) copper cable provides a high bandwidth connection up to 40 Gb/s (Quad Data Rate). Both ends of the cable have a QFSP connector. The cable connectors can be described as QSFP+/QSFP+ as well as QSFP/QSFP. Usage examples include a) connecting a PCIe2 InfiniBand QDR Adapter to a QDR IB switch or b) connecting two IBM Rack Switches together using QSFP+ ports.
- Attributes provided: 3 meter Quad Data Rate InfiniBand Copper Cable, QSFP/QSFP
- Attributes required: QDR InfiniBand QSFP port
- For 8205-E6D: (#3288)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#3289) - 5m QDR IB/E'Net Copper Cable QSFP/QSFP
This 5 meter Quad Data Rate (40Gb/s) InfinBand copper cable is used to connect the QDR Host Channel Adapter to QDR InfiniBand Switches.
- Attributes provided: 5 meter Quad Data Rate InfiniBand Copper Cable, QSFP/QSFP
- Attributes required: QDR InfiniBand port
- For 8205-E6D: (#3289)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#3290) - 10 meter Quad Data Rate InfiniBand Optical Cable, QSFP/QSFP
This 10 meter Quad Data Rate (40Gb/s) InfinBand optical cable is used to connect the QDR Host Channel Adapter to QDR InfiniBand Switches. It can also be used for QDR InfiniBand switch-to-switch applications.
- Attributes provided: 10 meter Quad Data Rate InfiniBand Optical Cable, QSFP/QSFP
- Attributes required: InfiniBand switch #3699, or follow-on
- For 8205-E6D: (#3290)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#3293) - 30 meter Quad Data Rate InfiniBand Optical Cable, QSFP/QSFP
This 30 meter Quad Data Rate (40Gb/s) InfinBand optical cable is used to connect the QDR Host Channel Adapter to QDR InfiniBand Switches. It can also be used for QDR InfiniBand switch-to-switch applications.
- Attributes provided: 30 meter Quad Data Rate InfiniBand Optical Cable, QSFP/QSFP
- Attributes required: InfiniBand switch #3699, or follow-on
- For 8205-E6D: (#3293)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#3450) - SAS YO Cable 1.5m - HD 6Gb Adapter to Enclosure
This 1.5 meter SAS cable connects a SAS adapter to a SAS I/O enclosure. This YO cable has three connectors, one Mini-SAS HD (High Density)connector and two Mini SAS connectors. The Mini-SAS HD connector attaches to a SAS adapter such as the #5913 1.8GB RAID SAS Adapter. Both Mini SAS connectors attach to the same I/O drawer (enclosure) such as a #5887 EXP24S SAS I/O drawer. This cable can support up to 6Gb throughput.
Multiple cable length feature codes are available. Choose the cable length that best matches the distance between the adapter and the SAS I/O drawer.
- Attributes provided: connection between SAS adapter with Mini-SAS HD connectors and a SAS I/O drawer with Mini SAS connectors
- Attributes required: available connectors on SAS controller and SAS I/O drawer
- For 8205-E6D: (#3450)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#3451) - SAS YO Cable 3m - HD 6Gb Adapter to Enclosure
This 6 meter SAS cable connects a SAS adapter to a SAS I/O enclosure. This YO cable has three connectors, one Mini-SAS HD (High Density)connector and two Mini SAS connectors. The Mini-SAS HD connector attaches to a SAS adapter such as the #5913 1.8GB RAID SAS Adapter. Both Mini SAS connectors attach to the same I/O drawer (enclosure) such as a #5887 EXP24S SAS I/O drawer. This cable can support up to 6Gb throughput.
Multiple cable length feature codes are available. Choose the cable length that best matches the distance between the adapter and the SAS I/O drawer.
- Attributes provided: connection between SAS adapter with Mini-SAS HD connectors and a SAS I/O drawer with Mini SAS connectors
- Attributes required: available connectors on SAS controller and SAS I/O drawer
- For 8205-E6D: (#3451)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#3452) - SAS YO Cable 6m - HD 6Gb Adapter to Enclosure
This 6 meter SAS cable connects a SAS adapter to a SAS I/O enclosure. This YO cable has three connectors, one Mini-SAS HD (High Density)connector and two Mini SAS connectors. The Mini-SAS HD connector attaches to a SAS adapter such as the #5913 1.8GB RAID SAS Adapter. Both Mini SAS connectors attach to the same I/O drawer (enclosure) such as a #5887 EXP24S SAS I/O drawer. This cable can support up to 6Gb throughput.
Multiple cable length feature codes are available. Choose the cable length that best matches the distance between the adapter and the SAS I/O drawer.
- Attributes provided: connection between SAS adapter with Mini-SAS HD connectors and a SAS I/O drawer with Mini SAS connectors
- Attributes required: available connectors on SAS controller and SAS I/O drawer
- For 8205-E6D: (#3452)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#3453) - SAS YO Cable 10m - HD 6Gb Adapter to Enclosure
This 10 meter SAS cable connects a SAS adapter to a SAS I/O enclosure. This YO cable has three connectors, one Mini-SAS HD (High Density)connector and two Mini SAS connectors. The Mini-SAS HD connector attaches to a SAS adapter such as the #5913 1.8GB RAID SAS Adapter. Both Mini SAS connectors attach to the same I/O drawer (enclosure) such as a #5887 EXP24S SAS I/O drawer. This cable can support up to 6Gb throughput.
Multiple cable length feature codes are available. Choose the cable length that best matches the distance between the adapter and the SAS I/O drawer.
- Attributes provided: connection between SAS adapter with Mini-SAS HD connectors and a SAS I/O drawer with Mini SAS connectors
- Attributes required: available connectors on SAS controller and SAS I/O drawer
- For 8205-E6D: (#3453)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#3454) - SAS X Cable 3m - HD 6Gb 2-Adapter to Enclosure
This 3 meter SAS cable connects two SAS adapters to a SAS I/O enclosure. This X cable has four connectors, two Mini-SAS HD (High Density) connector and two Mini SAS connectors. The Mini-SAS HD connectors attaches to two SAS adapters such as the #5913 1.8GB RAID SAS Adapter. Both Mini SAS connectors attach to the same I/O drawer (enclosure) such as a #5886 EXP12S or #5887 EXP24S SAS I/O drawer. This cable can support up to 6Gb throughput.
Multiple cable length feature codes are available. Choose the cable length that best matches the distance between the adapter and the I/O drawer. See SAS cabling documentation for the length of each leg of the cable. The SAS adapters can be in the same or in different PCIe I/O drawers. Or one adapters can be in a supported Power System CEC and the other adapter can be in a PCIe I/O drawer. Or both adapters can be in a supported Power System CEC.
- Attributes provided: connection between two SAS adapter with Mini-SAS HD connectors and a SAS I/O drawer with Mini SAS connectors
- Attributes required: available connectors on SAS controllers and SAS I/O drawer
- For 8205-E6D: (#3454)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#3455) - SAS X Cable 6m - HD 6Gb 2-Adapter to Enclosure
This 6 meter SAS cable connects two SAS adapters to a SAS I/O enclosure. This X cable has four connectors, two Mini-SAS HD (High Density) connector and two Mini SAS connectors. The Mini-SAS HD connectors attaches to two SAS adapters such as the #5913 1.8GB RAID SAS Adapter. Both Mini SAS connectors attach to the same I/O drawer (enclosure) such as a #5886 EXP12S or #5887 EXP24S SAS I/O drawer. This cable can support up to 6Gb throughput.
Multiple cable length feature codes are available. Choose the cable length that best matches the distance between the adapter and the I/O drawer. See SAS cabling documentation for the length of each leg of the cable. The SAS adapters can be in the same or in different PCIe I/O drawers. Or one adapters can be in a supported Power System CEC and the other adapter can be in a PCIe I/O drawer. Or both adapters can be in a supported Power System CEC.
- Attributes provided: connection between two SAS adapter with Mini-SAS HD connectors and a SAS I/O drawer with Mini SAS connectors
- Attributes required: available connectors on SAS controllers and SAS I/O drawer
- For 8205-E6D: (#3455)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#3456) - SAS X Cable 10m - HD 6Gb 2-Adapter to Enclosure
This 10 meter SAS cable connects two SAS adapters to a SAS I/O enclosure. This X cable has four connectors, two Mini-SAS HD (High Density) connector and two Mini SAS connectors. The Mini-SAS HD connectors attaches to two SAS adapters such as the #5913 1.8GB RAID SAS Adapter. Both Mini SAS connectors attach to the same I/O drawer (enclosure) such as a #5886 EXP12S or #5887 EXP24S SAS I/O drawer. This cable can support up to 6Gb throughput.
Multiple cable length feature codes are available. Choose the cable length that best matches the distance between the adapter and the I/O drawer. See SAS cabling documentation for the length of each leg of the cable. The SAS adapters can be in the same or in different PCIe I/O drawers. Or one adapters can be in a supported Power System CEC and the other adapter can be in a PCIe I/O drawer. Or both adapters can be in a supported Power System CEC.
- Attributes provided: connection between two SAS adapter with Mini-SAS HD connectors and a SAS I/O drawer with Mini SAS connectors
- Attributes required: available connectors on SAS controllers and SAS I/O drawer
- For 8205-E6D: (#3456)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#3457) - SAS YO Cable 15m - HD 3Gb Adapter to Enclosure
This 15 meter SAS cable connects a SAS adapter to a SAS I/O enclosure. This YO cable has three connectors, one Mini-SAS HD (High Density)connector and two Mini SAS connectors. The Mini-SAS HD connector attaches to a SAS adapter such as the #5913 1.8GB RAID SAS Adapter or #ESA1/ESA2 PCIe2 RAID SAS Adapter. Both Mini SAS connectors attach to the same I/O drawer (enclosure) such as a #5887 EXP24S SAS I/O drawer. This cable can support up to 3Gb throughput.
Multiple cable length feature codes are available. Choose the cable length that best matches the distance between the adapter and the SAS I/O drawer.
- Attributes provided: connection between SAS adapter with Mini-SAS HD connectors and a SAS I/O drawer with Mini SAS connectors
- Attributes required: available connectors on SAS controller and SAS I/O drawer
- For 8205-E6D: (#3457)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#3458) - SAS X Cable 15m - HD 3Gb 2-Adapter to Enclosure
This 15 meter SAS cable connects two SAS adapters to a SAS I/O enclosure. This X cable has four connectors, two Mini-SAS HD (High Density) connector and two Mini SAS connectors. The Mini-SAS HD connectors attaches to two SAS adapters such as the #5913 1.8GB RAID SAS Adapter or #ESA1/ESA2 PCIe2 RAID SAS Adapter. Both Mini SAS connectors attach to the same I/O drawer (enclosure) such as a #5886 EXP12S or #5887 EXP24S SAS I/O drawer. This cable can support up to 3Gb throughput.
Multiple cable length feature codes are available. Choose the cable length that best matches the distance between the adapter and the I/O drawer. See SAS cabling documentation for the length of each leg of the cable. The SAS adapters can be in the same or in different PCIe I/O drawers. Or one adapters can be in a supported Power System CEC and the other adapter can be in a PCIe I/O drawer. Or both adapters can be in a supported Power System CEC.
- Attributes provided: connection between two SAS adapter with Mini-SAS HD connectors and a SAS I/O drawer with Mini SAS connectors
- Attributes required: available connectors on SAS controllers and SAS I/O drawer
- For 8205-E6D: (#3458)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#3586) - 69GB 3.5" SAS Solid State Drive
The 69GB 3.5" SAS Solid State Drive (SSD) provides 69.7 GB of very high performance storage, much faster than spinning disk drives with their delays due to positioning the disk arm and waiting for the spinning disk to rotate under the arm. SSD also provide lower power utilization than spinning or hard disk drives (HDD). The drive is formatted to 69.7 GB and can be used by AIX, Linux (#3586) and IBM i (#3587). Both are identical drives, but have different feature codes to help the IBM configuration tools understand how the SSD is used.
- Connector - standard SAS dual port
- 3Gb/sec SAS device (300 MB/sec)
- 528 bytes sectors Power System
- Attributes provided: 69.7GB of formatted drive storage mounted in a 3.5-inch carrier
- Attributes required: One 3.5-inch SAS drive bay slot in the #5886 EXP 12S SAS Disk Drawer or 8234-EMA/9117-MMA CEC
- For 8205-E6D: (#3586)
- Minimum required: 0
- Maximum allowed: 224 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Maximum of 224 in 28 x #5886
(#3587) - 69GB 3.5" SAS Solid State Drive
The 69GB 3.5" SAS Solid State Drive (SSD) provides 69.7 GB of very high performance storage, much faster than spinning disk drives with their delays due to positioning the disk arm and waiting for the spinning disk to rotate under the arm. SSD also provide lower power utilization than spinning or hard disk drives (HDD). The drive is formatted to 69.7 GB and can be used by AIX, Linux (#3586) and IBM i (#3587). Both are identical drives, but have different feature codes to help the IBM configuration tools understand how the SSD is used.
- Connector - standard SAS dual port
- 3Gb/sec SAS device (300 MB/sec)
- 528 bytes sectors Power System
- Attributes provided: 69.7GB of formatted drive storage mounted in a 3.5-inch carrier
- Attributes required: One 3.5-inch SAS drive bay slot in the #5886 EXP 12S SAS Disk Drawer or 8234-EMA/9117-MMA CEC
- For 8205-E6D: (#3587)
- Minimum required: 0
- Maximum allowed: 224 (Initial order maximum: 0)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Maximum of 224 in 28 x #5886
(#3632) - Widescreen LCD Monitor
(No Longer Available as of August 08, 2017)
The Widescreen LCD Monitor has the following general characteristics:
- Black color
- Minimum 533mm (21 inch) diagonal LCD digital screen
- Maximum native resolution of 1680 x 1050 (widescreen format 1.6:1)
- Can display traditional resolutions (1024x768 and 1280x1024) without stretching
- Tilt, swivel, and height stand adjustments
- Industry standard analog input (15-pin D) and a DVI to VGA converter
- Attributes provided: Color Flat-panel Monitor
- Attributes required: Graphics Adapter
- Attributes provided: Color Flat-panel Monitor
- Attributes required: Graphics Adapter
- For 8205-E6D: (#3632)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note: Not supported in Mainland China.
(#3637) - IBM T541H /L150p 15" TFT Color Monitor
Both the T541H and L150p monitors have the following general characteristics:
- Business Black color
- 15-inch TFT LCD digital screen with a viewable image size of 381 mm (15.0 inches) measured diagonally, incorporating a 0.297 mm pixel pitch/type for bright, high-definition images.
- Designed to provide flicker free operation at a maximum resolution of 1024 x 768 pels at 75Hz in analog mode and 1024 x 768 pels at 60Hz in digital mode.
- Tilt/swivel stand
- Supports 2D Graphics Adapters only
- Attributes provided: Color Flat-panel Monitor
- Attributes required: 2D Graphics Adapter
- For 8205-E6D: (#3637)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#3639) - IBM ThinkVision L170p Flat Panel Monitor
The IBM ThinkVision L170p LCD flat-panel monitor has the following general characteristics:
- Business black color
- 17.0-inch LCD digital screen with a viewable image size of 432 mm (17.0 inches) measured diagonally, incorporating a 0.264mm pixel pitch/type for bright, high-definition images.
- Maximum resolution of 1280 x 1024.
- Tilt/swivel and height adjustable stand
- Analog or digital connection
- Dual input allows attachment to two systems concurrently.
- Internal power
- Depth: 237.0 mm (9.3 in.)
- Height: 457.0 mm (18.0 in.)
- Width: 400.0 mm (15.7 in.)
- Weight: 5.7 kg (12.6 lbs.)
- Viewing angle: Vertical 170 degrees; horizontal 170 degrees
- Contrast ratio: 500:1 (typical)
- Video inputs: 15-pin D / DVI-D
- Two removable cables: one analog and one digital
- Attributes provided: Color Flat-panel Monitor
- Attributes required: Graphics Adapter
- For 8205-E6D: (#3639)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#3640) - ThinkVision L171p Flat Panel Monitor
The ThinkVision L171p LCD flat-panel monitor has the following general characteristics:
- Business black color
- 17.0-inch LCD digital screen with a viewable image size of 432 mm (17.0 inches) measured diagonally, incorporating a 0.280mm pixel pitch/type for bright, high-definition images.
- Maximum resolution of 1280 x 1024.
- Tilt/swivel and height adjustable stand
- Analog or digital connection
- Dual input allows attachment to two systems concurrently.
- Internal power
- Depth: 237.0 mm (9.3 in.)
- Height: 457.0 mm (18.0 in.)
- Width: 400.0 mm (15.7 in.)
- Weight: 5.7 kg (12.6 lbs.)
- Viewing angle: Vertical 170 degrees; horizontal 170 degrees
- Contrast ratio: 800:1 (typical)
- Video inputs: 15-pin D / DVI-D
- Two removable cables: one analog and one digital
- RoHS compliant
- Attributes provided: Color Flat-panel Monitor
- Attributes required: Graphics Adapter
- For 8205-E6D: (#3640)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#3641) - IBM T115 Flat Panel Monitor
The IBM T115 LCD flat-panel monitor has the following general characteristics:
- Business black color
- 15.0-inch LCD digital screen with a viewable image size of 381 mm (15.0 inches) measured diagonally, incorporating a 0.297mm pixel pitch/type for bright, high-definition images.
- Maximum resolution of 1024 x 768 (XGA)
- Tilt adjustable stand
- Analog connection
- Internal power
- Depth (w/stand): 144 mm (6.67 inches)
- Height (max w/stand): 361 mm (14.2 inches
- Width: 362 mm (14.2 inches)
- Weight: 2.9 kg (6.4 lbs)
- Contrast ratio: 400:1 (typical)
- Brightness: 250cd/m2 (typical)
- Viewing angles (H/V): 130 degrees/100 degree
- Attributes provided: Color Flat-panel Monitor
- Attributes required: Graphics Adapter
- For 8205-E6D: (#3641)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#3642) - ThinkVision L191p Flat Panel Monitor
The ThinkVision L191p LCD flat-panel monitor has the following general characteristics:
- Business black color
- 19.0-inch LCD digital screen with a viewable image size of 483 mm (19.0 inches) measured diagonally, incorporating a 0.294mm pixel pitch/type for bright, high-definition images.
- Maximum resolution of 1280 x 1024.
- Tilt/swivel and height adjustable stand
- Analog or digital connection
- Dual input allows attachment to two systems concurrently.
- Internal power
- Depth: 237.0 mm (9.3 in.)
- Height: 457.0 mm (18.0 in.)
- Width: 408.0 mm (16.1 in.)
- Weight: 7.1 kg (15.7 lbs.)
- Contrast ratio: 1000:1 (typical)
- Video inputs: 15-pin D / DVI-D
- Two removable cables, one analog and one digital
- Attributes provided: Color Flat-panel Monitor
- Attributes required: Graphics Adapter
- For 8205-E6D: (#3642)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#3643) - IBM T120 Flat Panel Monitor
The IBM T120 LCD flat-panel monitor has the following general characteristics:
- Business black color
- 20.1-inch LCD digital screen with a viewable image size of 511 mm (20.1 inches) measured diagonally, incorporating a 0.255 mm pixel pitch/type for bright, high-definition images.
- Maximum resolution of 1600 x 1200 (UXGA)
- Tilt/lift adjustable stand
- Analog and digital connections
- Internal power
- Depth (w/stand): 246 mm (9.7 inches)
- Height (max w/stand): 416.6 mm (16.5 inches)
- Width: 445.6 mm (17.5 inches)
- Weight: 7.5 kg (16.5 lbs)
- Contrast ratio: 700:1 (typical)
- Brightness: 300cd/m2 (typical)
- Viewing angles(H/V): 178 degrees/178 degrees
- Video inputs: 15-pin D / DVI-D
- Two removable cables, one analog and one digital
- Attributes provided: Color Flat-panel Monitor
- Attributes required: Graphics Adapter
- For 8205-E6D: (#3643)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#3644) - IBM T119 Flat Panel Monitor
The IBM T119 LCD flat-panel monitor has the following general characteristics:
- Business black color
- 19.0-inch LCD digital screen with a viewable image size of 483 mm (19.0 inches) measured diagonally, incorporating a 0.294 mm pixel pitch/type for bright, high-definition images.
- Maximum resolution of 1280 x 1024 (SXGA)
- Tilt/lift adjustable stand
- Analog and digital connections
- Internal power
- Depth (w/stand): 246 mm (9.7 inches)
- Height (max w/stand): 443.6 mm (17.5 inches)
- Width: 418 mm (16.5 inches)
- Weight: 7.4 kg (16.3 lbs)
- Contrast ratio: 550:1 (typical)
- Brightness: 250cd/m2 (typical)
- Viewing angles (H/V): 140 degrees/135 degrees
- Video inputs: 15-pin D / DVI-D
- Two removable cables, one analog and one digital
- Attributes provided: Color Flat-panel Monitor
- Attributes required: Graphics Adapter
- For 8205-E6D: (#3644)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#3645) - IBM T117 Flat Panel Monitor
The IBM T117 LCD flat-panel monitor has the following general characteristics:
- Business black color
- 17.0-inch LCD digital screen with a viewable image size of 432 mm (17.0 inches) measured diagonally, incorporating a 0.264 mm pixel pitch/type for bright, high-definition images.
- Maximum resolution of 1280 x 1024 (SXGA)
- Tilt/lift adjustable stand
- Analog and digital connections
- Internal power
- Depth (w/stand): 246 mm (9.7 inches)
- Height (max w/stand): 395.5 mm (15.6 inches)
- Width: 375.4 mm (14.8 inches)
- Weight: 5.8 kg (12.8 lbs)
- Contrast ratio: 500:1 (typical)
- Brightness: 300cd/m2 (typical)
- Viewing angles (H/V): 140 degrees/130 degrees
- Video inputs: 15-pin D / DVI-D
- Two removable cables, one analog and one digital
- Attributes provided: Color Flat-panel Monitor
- Attributes required: Graphics Adapter
- For 8205-E6D: (#3645)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#3646) - 73GB 15K RPM SAS Disk Drive
73.4GB Serial Attached SCSI (SAS) DASD device, in a carrier capable of providing Hot Swap support. Provides 73.4GB of storage capacity. Supports the industry standard SAS interface. Can be used only in a drawer/system designed to support the SAS interface.
Characteristics:
- Form Factor: 3.5 inch Form Factor, 1 inch drive.
- Cable included: No
- External Interface: standard SAS Dual Port
- Rotational Speed: 15,000 RPM
- Interface Speed: 300 MB/sec.
- Format: 512 Bytes/sector default, 528 Bytes/sector possible with reformat.
- Attributes provided: 73.4GB of disk storage mounted in a carrier.
- Attributes required: one disk drive bay
- For 8205-E6D: (#3646)
- Minimum required: 0
- Maximum allowed: 336 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC.
- System maximum of 336 with 28 x #5886
(#3647) - 146GB 15K RPM SAS Disk Drive (AIX/Linux)
146.8GB Serial Attached SCSI (SAS) DASD device, in a carrier capable of providing Hot Swap support. Provides 146.8GB of storage capacity. Supports the industry standard SAS SCSI interface. Can be used only in a drawer/system designed to support the SAS SCSI interface.
Characteristics:
- Form Factor: 3.5 inch Form Factor, 1 inch drive.
- Cable included: No
- External Interface: standard SAS Dual Port
- Rotational Speed: 15,000 RPM
- Interface Speed: 300 MB/sec.
- Format: 512 Bytes/sector default, 528 Bytes/sector possible with reformat.
- Attributes provided: 146.8GB of Disk Storage mounted in a carrier
- Attributes required: one SAS Drive Slot
- For 8205-E6D: (#3647)
- Minimum required: 0
- Maximum allowed: 336 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC.
- System maximum of 336 with 28 x #5886
(#3648) - 300GB 15K RPM SAS Disk Drive (AIX/Linux)
300GB Serial Attached SCSI (SAS) DASD device, in a carrier capable of providing Hot Swap support. Provides 300GB of storage capacity. Supports the industry standard SAS SCSI interface. Can be used only in a drawer/system designed to support the SAS SCSI interface.
Characteristics:
- Form Factor: 3.5 inch Form Factor, 1 inch drive.
- Cable included: No
- External Interface: standard SAS Dual Port
- Rotational Speed: 15,000 RPM
- Interface Speed: 300 MB/sec.
- Format: 512 Bytes/sector default, 528 Bytes/sector possible with reformat.
- Attributes provided: 300GB of Disk Storage mounted in a carrier
- Attributes required: one SAS Drive Slot
- For 8205-E6D: (#3648)
- Minimum required: 0
- Maximum allowed: 336 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC.
- System maximum of 336 with 28 x #5886
(#3649) - 450GB 15K RPM SAS Disk Drive (AIX/Linux)
Attached SAS DASD device, in a carrier capable of providing Hot Swap support. Provides 450GB of storage capacity. Supports the industry standard SAS interface. Can be used only in a drawer/system designed to support the SAS interface.
Characteristics:
- Form Factor: 3.5 inch Form Factor, 1 inch drive.
- Cable included: No
- External Interface: standard SAS Dual Port
- Rotational Speed: 15,000 RPM
- Interface Speed: 300 MB/sec.
- Format: 512 Bytes/sector default, 528 Bytes/sector possible with re-format.
- Attributes provided: 450GB of disk storage mounted in a carrier.
- Attributes required: one SAS disk drive bay
- For 8205-E6D: (#3649)
- Minimum required: 0
- Maximum allowed: 336 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC.
- System maximum of 336 with 28 x #5886
(#3652) - SAS Cable (EE) Drawer to Drawer 1M
SAS Cable (EE), connects a second SAS disk drawer to a primary SAS disk drawer attached to a SAS controller adapter. This cable has one Mini SAS 4x cable plug connector on each end. Both connectors must be attached to an ENCLOSURE UP Arrow port on the ESM module of the attaching drawers. Follow the directions on the connector labels when attaching the connectors on this cable. This cable supports both Single and Dual path configurations. All supported configurations require two of this feature to attach a secondary disk drawer to the primary disk drawer. The length of this cable is 1 meter. Choose the SAS (EE) cable length to match the distance between the two SAS drawers.
- Attributes provided: SAS Disk drawer to SAS Disk drawer attach cable
- Attributes required: none
- For 8205-E6D: (#3652)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#3653) - SAS Cable (EE) Drawer to Drawer 3M
SAS Cable (EE), connects a second SAS disk drawer to a primary SAS disk drawer attached to a SAS controller adapter. This cable has one Mini SAS 4x cable plug connector on each end. Both connectors must be attached to an ENCLOSURE UP Arrow port on the ESM module of the attaching drawers. Follow the directions on the connector labels when attaching the connectors on this cable. This cable supports both Single and Dual path configurations. All supported configurations require two of this feature to attach a secondary disk drawer to the primary disk drawer. The length of this cable is 3 meter. Choose the SAS (EE) cable length to match the distance between the two SAS drawers.
- Attributes provided: SAS Disk drawer to SAS Disk drawer attach cable
- Attributes required: none
- For 8205-E6D: (#3653)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#3654) - SAS Cable (EE) Drawer to Drawer 6M
SAS Cable (EE), connects a second SAS disk drawer to a primary SAS disk drawer attached to a SAS controller adapter. This cable has one Mini SAS 4x cable plug connector on each end. Both connectors must be attached to an ENCLOSURE UP Arrow port on the ESM module of the attaching drawers. Follow the directions on the connector labels when attaching the connectors on this cable. This cable supports both Single and Dual path configurations. All supported configurations require two of this feature to attach a secondary disk drawer to the primary disk drawer. The length of this cable is 6 meter. Choose the SAS (EE) cable length to match the distance between the two SAS drawers.
- Attributes provided: SAS Disk drawer to SAS Disk drawer attach cable
- Attributes required: none
- For 8205-E6D: (#3654)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#3656) - SAS SFF Cable
This cable will connect an internal media device with a 4x standard SAS connector to a system unit embedded controller. The cable has a standard 4x SAS connector on one end and a 1x SAS and 4-pin power connector (arranged 2x2) on the other.
- Attributes provided: Internal 267 mm long SAS cable
- Attributes required: None
- For 8205-E6D: (#3656)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#3658) - 428GB 15K RPM SAS Disk Drive (IBM i)
Attached SAS DASD device, in a carrier capable of providing Hot Swap support. Provides 428GB of storage capacity. Supports the industry standard SAS interface. Can be used only in a drawer/system designed to support the SAS interface.
Characteristics:
- Form Factor: 3.5 inch Form Factor, 1 inch drive.
- Cable included: No
- External Interface: standard SAS Dual Port
- Rotational Speed: 15,000 RPM
- Interface Speed: 300 MB/sec.
- Format: 528 Bytes/sector default, 512 B
Note: This drive is not supported as a load source drive for POWER5/POWER5+ systems.
- Attributes provided: 428GB SAS disk storage mounted in a carrier.
- Attributes required: one SAS disk drive bay
- For 8205-E6D: (#3658)
- Minimum required: 0
- Maximum allowed: 336 (Initial order maximum: 0)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: No
Note:
- Not supported in the CEC.
- System maximum of 336 with 28 x #5886
(#3661) SAS Cable (X) Adapter to SAS Enclosure, Dual Controller/Dual Path 3M:
This SAS cable (X) connects a SAS disk drawer to two SAS controller adapters. This cable supports dual controller/dual path attach between two SAS controller adapters and the SAS disk drawer. The SAS controller adapters can be in the same or in different host systems. This cable has four Mini SAS 4x plug connectors. Two of the Mini SAS 4x plug connectors attach to the adapters and are keyed as END DEVICES. Two of the Mini SAS 4x plug connectors attach to the SAS disk drawer and are keyed for ENCLOSURE DOWN Arrow. All of the connectors are wired in 2x mode. Follow the directions on the connector labels when attaching the connectors on this cable. This cable is 3 meters long, choose the SAS (X) cable length that matches the distance between the adapters and the SAS disk drawer. The adapter legs of this cable are each 2.5 meters long.
- Attributes provided: Connection between two SAS controller adapters and a SAS disk drawer
- Attributes required: None
- For 8205-E6D: (#3661)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#3662) SAS Cable (X) Adapter to SAS Enclosure, Dual Controller/Dual Path 6M:
This SAS cable (X) connects a SAS disk drawer to two SAS controller adapters. This cable supports dual controller/dual path attach between two SAS controller adapters and the SAS disk drawer. The SAS controller adapters can be in the same or in different host systems. This cable has four Mini SAS 4x plug connectors. Two of the Mini SAS 4x plug connectors attach to the adapters and are keyed as END DEVICES. Two of the Mini SAS 4x plug connectors attach to the SAS disk drawer and are keyed for ENCLOSURE DOWN Arrow. All of the connectors are wired in 2x mode. Follow the directions on the connector labels when attaching the connectors on this cable. This cable is 6 meters long, choose the SAS (X) cable length that matches the distance between the adapters and the SAS disk drawer. The adapter legs of this cable are each 5.5 meters long.
- Attributes provided: Connection between two SAS controller adapters and a SAS disk drawer
- Attributes required: None
- For 8205-E6D: (#3662)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#3663) SAS Cable (X) Adapter to SAS Enclosure, Dual Controller/Dual Path 15M:
This SAS cable (X) connects a SAS disk drawer to two SAS controller adapters. This cable supports dual controller/dual path attach between two SAS controller adapters and the SAS disk drawer. The SAS controller adapters can be in the same or in different host systems. This cable has four Mini SAS 4x plug connectors. Two of the Mini SAS 4x plug connectors attach to the adapters and are keyed as END DEVICES. Two of the Mini SAS 4x plug connectors attach to the SAS disk drawer and are keyed for ENCLOSURE DOWN Arrow. All of the connectors are wired in 2x mode. Follow the directions on the connector labels when attaching the connectors on this cable. This cable is 15 meters long, choose the SAS (X) cable length that matches the distance between the adapters and the SAS disk drawer. The adapter legs of this cable are each 14.5 meters long.
- Attributes provided: Connection between two SAS controller adapters and a SAS disk drawer
- Attributes required: None
- For 8205-E6D: (#3663)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#3675) - SAS EX Cable 3m - Drawer to Drawer
The SAS EX Cable is a straight line cable with a HD SAS connector on one end and a mini SAS connector on the other end. The cable is rated at 6 Gbps. A pair of these cables connects the EXP30 Ultra SSD I/O Drawer (#EDR1) to an EXP24S I/O Drawer (#5887).
Select the length appropriate to your configuration. #5926 is 1.5m. #3675 is 3m, #3680 is 6m.
- Attributes required: None
- For 8205-E6D: (#3675)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#3676) - 69.7GB 15k rpm SAS Disk Drive
Provides a 15,000 RPM, 3.5-inch disk unit with 69.7GB capacity and a Serially Attached SCSI (SAS) interface. #3676 is mounted in a carrier and Hot Swap is supported.
- Attributes provided: 69.7GB Disk Unit
- Attributes required: Disk Unit Slot and a SAS Disk Unit Controller
- For 8205-E6D: (#3676)
- Minimum required: 0
- Maximum allowed: 336 (Initial order maximum: 0)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC.
- System maximum of 336 with 28 x #5886
(#3677) - 139.5GB 15k rpm SAS Disk Drive (IBM i)
Provides a 15,000 RPM, 3.5-inch disk unit with 139.5GB capacity and a Serially Attached SCSI (SAS) interface. #3677 is mounted in a carrier and hot swap is supported.
- Attributes provided: 139.5GB Disk Unit in a carrier
- Attributes required: one SAS drive slot
- For 8205-E6D: (#3677)
- Minimum required: 0
- Maximum allowed: 336 (Initial order maximum: 0)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC.
- System maximum of 336 with 28 x #5886
(#3678) - 283.7GB 15k rpm SAS Disk Drive (IBM i)
Provides a 15,000 RPM, 3.5-inch disk unit with 283.7GB capacity and a Serially Attached SCSI (SAS) interface. #3678 is mounted in a carrier and hot swap is supported.
- Attributes provided: 283.7GB Disk Unit in a carrier
- Attributes required: one SAS drive slot
- For 8205-E6D: (#3678)
- Minimum required: 0
- Maximum allowed: 336 (Initial order maximum: 0)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC.
- System maximum of 336 with 28 x #5886
(#3680) - SAS EX Cable 6m - Drawer to Drawer
The SAS EX Cable is a straight line cable with a HD SAS connector on one end and a mini SAS connector on the other end. The cable is rated at 6 Gbps. A pair of these cables connects the EXP30 Ultra SSD I/O Drawer (#EDR1) to an EXP24S I/O Drawer (#5887).
Select the length appropriate to your configuration. #5926 is 1.5m. #3675 is 3m, #3680 is 6m.
- For 8205-E6D: (#3680)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#3681) - 3M SAS CABLE, ADPTR TO ADPTR (AA)
The dedicated 2:6 cable connects between the dedicated top port on #5904, #5906 or #5908 for a SAS RAID Dual controller configuration providing (higher performance) path for all the dual controller communication including the mirroring of Write Cache and Parity update footprints between the adapters.
If the cable fails or is disconnected for some reason, then the "traditional" dual controller communication path via the SAS fabric (i.e. through the common disk expanders) is used for the adapter-to- adapter communication (mirror Write Cache, Parity Update footprints, etc...). This cable provides higher performance and redundancy. The cable is required for dual SAS RAID configuration. It is not required nor used for a single SAS RAID adapter (standalone) configuration.
- Attributes provided: Higher performance path for all the dual controller communication including the mirroring of Write Cache and Parity update footprints between the adapters.
- Attributes required: Two of any combination of the following SAS RAID adapters #5904, #5906 or 5908.
- For 8205-E6D: (#3681)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note: Requires one per paired SAS RAID controller in any combination of #5904, #5906 or #5908. These controllers can also function as a single SAS RAID controller without the cable. VIOS 2.2 or later.
(#3682) - 6M SAS CABLE, ADPTR TO ADPTR (AA)
The dedicated 2:6 cable connects between the dedicated top port on #5904, #5906 or #5908 for a SAS RAID Dual controller configuration providing (higher performance) path for all the dual controller communication including the mirroring of Write Cache and Parity update footprints between the adapters.
If the cable fails or is disconnected for some reason, then the "traditional" dual controller communication path via the SAS fabric (i.e. through the common disk expanders) is used for the adapter-to- adapter communication (mirror Write Cache, Parity Update footprints, etc...). This cable provides higher performance and redundancy. The cable is required for dual SAS RAID configuration. It is not required nor used for a single SAS RAID adapter (standalone) configuration.
- Attributes provided: Higher performance path for all the dual controller communication including the mirroring of Write Cache and Parity update footprints between the adapters.
- Attributes required: Two of any combination of the following SAS RAID adapters #5904, #5906 or 5908.
- For 8205-E6D: (#3682)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note: Requires one per paired SAS RAID controller in any combination of #5904, #5906 or #5908. These controllers can also function as a single SAS RAID controller without the cable. VIOS 2.2 or later.
(#3684) SAS Cable (AE) Adapter to Enclosure, single controller/single path 3M
This adapter-to-enclosure (AE) SAS cable most commonly connects a SAS controller to a media expansion drawer.
For AIX and Linux, this cable can also be used to connect two SAS adapters to a SAS disk drawer in a specific dual controller HA two system JBOD configuration using two #5912 controllers. Single controller/single path connections are supported with this cable only for this specific JBOD configuration, and, as such, two #5912 SAS controllers and two (AE style) cables are required for a supported configuration. The two SAS adapters must be in different host systems/partitions.
This cable has one mini SAS 4X plug connector on the adapter end wired in 4x mode and one mini SAS 4X plug connector on the drawer end, wired in 4x mode. Follow the directions on the connector labels when attaching the connectors on this cable. This cable is three meters long. Select the SAS (AE) cable length that best matches the distance between the host system and the remote SAS drawer being attached.
- Attributes provided: Connection between a SAS controller and a media expansion drawer or for AIX and Linux connection between #5912 SAS controller and a SAS disk drawer in a dual controller HA two system JBOD configuration only
- Attributes required: none
- For 8205-E6D: (#3684)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#3685) SAS Cable (AE) Adapter to Enclosure, single controller/single path 6M
This adapter-to-enclosure (AE) SAS cable most commonly connects a SAS controller to a media expansion drawer.
For the AIX and Linux operating systems, this cable can also be used to connect two SAS adapters to a SAS disk drawer in a specific dual controller HA two system JBOD configuration using two #5912 controllers. Single controller/single path connections are supported with this cable only for this specific JBOD configuration, and, as such, two #5912 SAS controllers and two (AE style) cables are required for a supported configuration. The two SAS adapters must be in different host systems/partitions.
This cable has one mini SAS 4X plug connector on the adapter end wired in 4x mode and one mini SAS 4X plug connector on the drawer end, wired in 4x mode. Follow the directions on the connector labels when attaching the connectors on this cable. This cable is three meters long. Select the SAS (AE) cable length that best matches the distance between the host system and the remote SAS drawer being attached.
- Attributes provided: Connection between a SAS controller and a media expansion drawer or for AIX and Linux connection between #5912 SAS controller and a SAS disk drawer in a dual controller HA two system JBOD configuration only
- Attributes required: none
- For 8205-E6D: (#3685)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#3687) SAS Cable (YI) System to SAS Enclosure, Single Controller/Dual Path 3M
This SAS cable (YI) connects a single remote SAS drawer to a host system that contains an integrated SAS controller connection. There are a limited number of Power System severs that can support this configuration. This cable supports single controller/dual path attach between the SAS controller and the SAS disk drawer. This cable has one Mini SAS 4X plug connector on the host end keyed as ENCLOSURE UP Arrow, wired in 4x mode and two Mini SAS 4X plug connector on the drawer end keyed as ENCLOSURE UP Arrow both wired in 2x mode. Follow the directions on the connector labels when attaching the connectors on this cable. This cable is 3 meters long, choose the SAS (YI) cable length that matches the distance between the host system and the SAS disk drawer.
- Attributes provided: Connection between host system native SAS connector and a remote SAS drawer
- Attributes required: Host system with native SAS connector
- For 8205-E6D: (#3687)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#3688) - SAS Cable (AT) 0.6 Meter
This 0.6 Meter SAS Cable (AT) is used to drive the 12X I/O Drawer Small Form Factor disk using PCIe SAS adapters installed in the drawer. If SFF disk is installed in the 12X I/O Drawer PCIe, SFF disk, then there must be at least one SAS AT cable assigned.
- Attributes provided: 0.6 Meter SAS Cable (AT)
- Attributes required: 12X I/O Drawer with a PCIe SAS adapter
- For 8205-E6D: (#3688)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#3689) - SAS AT Cable 0.6m - HD 6Gb Adapter to 12X Enclosure (AT)
This 0.6 meter SAS cable connects a SAS adapter located in a PCIe I/O drawer to a SAS port on that same I/O drawer. This AT cable has two connectors, one Mini-SAS HD (High Density) connector and one Mini SAS connector. The Mini-SAS HD connector attaches to a SAS adapter such as the #5913 1.8GB RAID SAS Adapter. The Mini SAS connectors attaches to the I/O drawer (enclosure) such as a #5802 or #5803 12X PCIe I/O drawer. This cable can support up to 6Gb throughput.
- Attributes provided: connection between SAS adapter with Mini-SAS HD SA connectors and a SAS I/O drawer with Mini SAS connectors
- Attributes required: available connectors on SAS controller and SAS I/O drawer. Adapter must be in that same I/O drawer.
- For 8205-E6D: (#3689)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#3691) SAS Cable (YO) Adapter to SAS Enclosure, Single Controller/Dual Pa th 1.5 M
This SAS cable (YO) connects a remote SAS drawer to a SAS controller adapter. This cable supports single controller/dual path attach between the SAS controller adapter and the SAS disk drawer. This cable has one Mini SAS 4X plug connector on the adapter end keyed for an END DEVICE, wired in 4x mode and two Mini SAS 4X plug connectors on the drawer end keyed for ENCLOSURE DOWN Arrow, both are wired in 2x mode. Follow the directions on the connector labels when attaching the connectors on this cable. This cable is 1.5 meters long, choose the SAS (YO) cable length that matches the distance between the adapter and the SAS disk drawer.
- Attributes provided: connection between SAS controller adapter and a SAS disk drawer
- Attributes required: none
- For 8205-E6D: (#3691)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#3692) SAS Cable (YO) Adapter to SAS Enclosure, Single Controller/Dual Path 3M
This SAS cable (YO) connects a remote SAS drawer to a SAS controller adapter. This cable supports single controller/dual path attach between the SAS controller adapter and the SAS disk drawer. This cable has one Mini SAS 4X plug connector on the adapter end keyed for an END DEVICE, wired in 4x mode and two Mini SAS 4X plug connectors on the drawer end keyed for ENCLOSURE DOWN Arrow, both are wired in 2x mode. Follow the directions on the connector labels when attaching the connectors on this cable. This cable is 3 meters long, choose the SAS (YO) cable length that matches the distance between the adapter and the SAS disk drawer.
- Attributes provided: connection between SAS controller adapter and a SAS disk drawer
- Attributes required: none
- For 8205-E6D: (#3692)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#3693) SAS Cable (YO) Adapter to SAS Enclosure, Single Controller/Dual Path 6M
This SAS cable (YO) connects a remote SAS drawer to a SAS controller adapter. This cable supports single controller/dual path attach between the SAS controller adapter and the SAS disk drawer. This cable has one Mini SAS 4X plug connector on the adapter end keyed for an END DEVICE, wired in 4x mode and two Mini SAS 4X plug connectors on the drawer end keyed for ENCLOSURE DOWN Arrow, both are wired in 2x mode. Follow the directions on the connector labels when attaching the connectors on this cable. This cable is 6 meters long, choose the SAS (YO) cable length that matches the distance between the adapter and the SAS disk drawer.
- Attributes provided: connection between SAS controller adapter and a SAS disk drawer
- Attributes required: none
- For 8205-E6D: (#3693)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#3694) SAS Cable (YO) Adapter to SAS Enclosure, Single Controller/Dual Path 15M
This SAS cable (YO) connects a remote SAS drawer to a SAS controller adapter. This cable supports single controller/dual path attach between the SAS controller adapter and the SAS disk drawer. This cable has one Mini SAS 4X plug connector on the adapter end keyed for an END DEVICE, wired in 4x mode and two Mini SAS 4X plug connectors on the drawer end keyed for ENCLOSURE DOWN Arrow, both are wired in 2x mode. Follow the directions on the connector labels when attaching the connectors on this cable. This cable is 15 meters long, choose the SAS (YO) cable length that matches the distance between the adapter and the SAS disk drawer.
- Attributes provided: connection between SAS controller adapter and a SAS disk drawer
- Attributes required: none
- For 8205-E6D: (#3694)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#3925) - 0.3M Serial Port Converter Cable, 9-Pin to 25-Pin
This cable converts the 9-pin serial port on the system to a 25-pin serial port which allows the user to attach 25-pin serial devices to the system.
- Attributes provided: 9-Pin to 25-Pin connectivity
- Attributes required: None
- For 8205-E6D: (#3925)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#3927) - Serial Port Null Modem Cable, 9-pin to 9-pin, 3.7M
This 3.7 meter 9 pin to 9 pin Null modem Serial cable allows two EIA-232 communications ports to exchange data with one another without going through a modem.
- Attributes provided: 9 pin female connector at each end of the cable
- Attributes required: none
- For 8205-E6D: (#3927)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#3928) - Serial Port Null Modem Cable, 9-pin to 9-pin, 10M
This 10 meter 9 pin to 9 pin Null Modem Serial cable allows two EIA-232 communications ports to exchange data with one another without going through a modem.
- Attributes provided: 9 pin female connector at each end of the cable
- Attributes required: none
- For 8205-E6D: (#3928)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#3930) - System Serial Port Converter Cable
This cable is used to connect the System port/UPS Conversion Cable (#1827) to the CEC serial port. Also used to connect an ASCII terminal or modem to the serial port which is physically an RJ45 connection on the Power 710/720/730/740 system unit .
- Attributes provided: Attachment of #1827 to CEC serial port; attachment of ASCII terminal or modem to the serial port.
- Attributes required: None
- For 8205-E6D: (#3930)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#4242) 1.8 M (6-ft) Extender Cable for Displays (15-pin D-shell to 15-pin D-shell)
(No Longer Available as of March 31, 2018)
This cable is required to connect displays with a 15-pin "D" shell connector to the appropriate accelerator connector when it is farther away than the attached monitor cable can reach. Rack mounted systems are likely candidates for this extender cable.
- Attributes provided: 6-foot extension cable
- Attributes required: Supported monitor and adapter with a 15-pin "D" shell connector.
- For 8205-E6D: (#4242)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#4256) - Extender Cable - USB Keyboards, 1.8M
This feature provides a 1.8M extension cable for use with USB keyboards.
- Attributes provided: 1.8M Extension Cable
- Attributes required: USB Keyboard
- For 8205-E6D: (#4256)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#4276) - VGA to DVI Connection Converter
This feature is a plug converter that will allow a Video device with a 15 pin D-shell VGA cable plug (such as a KVM switch) to connect to a graphics adapter with a 28 pin D-shell DVI receptacle connector. This device has both a 28 pin D-Shell DVI plug and a 15 pin D-shell VGA receptacle.
- Attributes provided: VGA to DVI connection converter
- Attributes required: VGA device and graphics adapter with DVI connector.
- For 8205-E6D: (#4276)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#4367) - Package 5X #2055 & 20X #1995 (AIX/Linux)
(No Longer Available as of August 23, 2013)
This feature will deliver a packaged of five PCIe RAID & SSD SAS Adapters 3Gb w/ Blind Swap Cassette (equivalent to #2055) and twenty 177GB SSD Modules with eMLC (equivalent to #1995) for AIX and Linux.
Feature 4367 is used to order and remains in IBM AAS records. Features #2055 and #1995 are not used with this feature.
- Attributes provided: 5 x #2055 and 20 x #1995
- Attributes required: None
- For 8205-E6D: (#4367)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#4377) - Package 5X #2055 & 20X #1996 (IBM i)
(No Longer Available as of August 23, 2013)
This feature will deliver a packaged of five PCIe RAID & SSD SAS Adapters 3Gb w/ Blind Swap Cassette (equivalent to #2055) and twenty 177GB SSD Modules with eMLC (equivalent to #1996) for IBM i.
Feature 4367 is used to order and to remains in IBM AAS records. Features #2055 and #1996 are not used with this feature.
- Attributes provided: 5 x #2055 and 20 x #1996
- Attributes required: None
- For 8205-E6D: (#4377)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#4650) - Rack Indicator- Not Factory Integrated
(No Longer Available as of November 30, 2015)
This indicator is used to specify that the rack mountable device in this initial order should not be merged into a rack within IBM Manufacturing.
Note: This "no additional charge" feature will be placed on an initial order for a rack mountable device by the Configuration Tool when the order does not include a 19" Rack.
A rack integration indicator is required on all 19" Rack mountable device initial orders. One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed.
- Attributes provided: System will not be shipped in a rack.
- Attributes required: None
- For 8205-E6D: (#4650)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#4651) - Rack Indicator, Rack #1
(No Longer Available as of November 30, 2015)
When added to an initial rack order, this indicator is used to specify the first rack for a multi rack order, or the only rack for a single rack order.
When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #1.
Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.
- Attributes provided: Rack Integration/ Rack Specify
- Attributes required: Rack
- For 8205-E6D: (#4651)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#4652) - Rack Indicator, Rack #2
(No Longer Available as of November 30, 2015)
When added to an initial rack order, this indicator is used to specify the second rack for a multi rack order.
When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #2 of a multi rack order.
Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.
- Attributes provided: Rack Integration/Rack specify
- Attributes required: Rack
- For 8205-E6D: (#4652)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#4653) - Rack Indicator, Rack #3
(No Longer Available as of November 30, 2015)
When added to an initial rack order, this indicator is used to specify the third rack for a multi rack order.
When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #3 of a multi rack order.
Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.
- Attributes provided: Rack specify
- Attributes required: Rack
- For 8205-E6D: (#4653)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#4654) - Rack Indicator, Rack #4
(No Longer Available as of November 30, 2015)
When added to an initial rack order, this indicator is used to specify the fourth rack for a multi rack order.
When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #4 of a multi rack order.
Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.
- Attributes provided: Rack specify
- Attributes required: Rack
- For 8205-E6D: (#4654)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#4655) - Rack Indicator, Rack #5
(No Longer Available as of November 30, 2015)
When added to an initial rack order, this indicator is used to specify the fifth rack for a multi rack order.
When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #5 of a multi rack order.
Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.
- Attributes provided: Rack specify
- Attributes required: Rack
- For 8205-E6D: (#4655)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#4656) - Rack Indicator, Rack #6
(No Longer Available as of November 30, 2015)
When added to an initial rack order, this indicator is used to specify the sixth rack for a multi rack order.
When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #6 of a multi rack order.
Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.
- Attributes provided: Rack specify
- Attributes required: Rack
- For 8205-E6D: (#4656)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#4657) - Rack Indicator, Rack #7
(No Longer Available as of November 30, 2015)
When added to an initial rack order, this indicator is used to specify the seventh rack for a multi rack order.
When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #7 of a multi rack order.
Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.
- Attributes provided: Rack specify
- Attributes required: Rack
- For 8205-E6D: (#4657)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#4658) - Rack Indicator, Rack #8
(No Longer Available as of November 30, 2015)
When added to an initial rack order, this indicator is used to specify the eighth rack for a multi rack order.
When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #8 of a multi rack order.
Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.
- Attributes provided: Rack specify
- Attributes required: Rack
- For 8205-E6D: (#4658)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#4659) - Rack Indicator, Rack #9
(No Longer Available as of November 30, 2015)
When added to an initial rack order, this indicator is used to specify the ninth rack for a multi rack order.
When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #9 of a multi rack order.
Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.
- Attributes provided: Rack specify
- Attributes required: Rack
- For 8205-E6D: (#4659)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#4660) - Rack Indicator, Rack #10
(No Longer Available as of November 30, 2015)
When added to an initial rack order, this indicator is used to specify the tenth rack for a multi rack order.
When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #10 of a multi rack order.
Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.
- Attributes provided: Rack specify
- Attributes required: Rack
- For 8205-E6D: (#4660)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#4661) - Rack Indicator, Rack #11
(No Longer Available as of November 30, 2015)
When added to an initial rack order, this indicator is used to specify the eleventh rack for a multi rack order.
When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #11 of a multi rack order.
Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.
- Attributes provided: Rack specify
- Attributes required: Rack
- For 8205-E6D: (#4661)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#4662) - Rack Indicator, Rack #12
(No Longer Available as of November 30, 2015)
When added to an initial rack order, this indicator is used to specify the twelfth rack for a multi rack order.
When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #12 of a multi rack order.
Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.
- Attributes provided: Rack specify
- Attributes required: Rack
- For 8205-E6D: (#4662)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#4663) - Rack Indicator, Rack #13
(No Longer Available as of November 30, 2015)
When added to an initial rack order, this indicator is used to specify the thirteenth rack for a multi rack order.
When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #13 of a multi rack order.
Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.
- Attributes provided: Rack specify
- Attributes required: Rack
- For 8205-E6D: (#4663)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#4664) - Rack Indicator, Rack #14
(No Longer Available as of November 30, 2015)
When added to an initial rack order, this indicator is used to specify the fourteenth rack for a multi rack order.
When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #14 of a multi rack order.
Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.
- Attributes provided: Rack specify
- Attributes required: Rack
- For 8205-E6D: (#4664)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#4665) - Rack Indicator, Rack #15
(No Longer Available as of November 30, 2015)
When added to an initial rack order, this indicator is used to specify the fifteenth rack for a multi rack order.
When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #15 of a multi rack order.
Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.
- Attributes provided: Rack specify
- Attributes required: Rack
- For 8205-E6D: (#4665)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#4666) - Rack Indicator, Rack #16
(No Longer Available as of November 30, 2015)
When added to an initial rack order, this indicator is used to specify the sixteenth rack for a multi rack order.
When added to an initial rack mountable device order, this indicator is used to specify that the rack mountable device (such as a system or I/O drawer) is to be mounted in rack #16 of a multi rack order.
Note: For 19" rack mountable device orders: One feature code from the group 4650 to 4666 must be listed on the order. More than one feature code from this group is not allowed. For 19" rack orders: If IBM Mfg. is to assemble a rack mountable device into the rack, one feature code selection from the group 4651 to 4666 must be listed on the order. More than one feature code selection from this group is not allowed. The quantity of this selected feature code on the 19" rack order must equal the number of rack mountable devices to be installed in the rack by IBM Mfg.
- Attributes provided: Rack specify
- Attributes required: Rack
- For 8205-E6D: (#4666)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#4764) - PCI-X Cryptographic Coprocessor (FIPS 4)
Provides both cryptographic coprocessor and secure-key cryptographic accelerator functions in a single PCI-X card. The coprocessor functions are targeted to banking and finance applications. Financial PIN processing and Europay, MasterCard, Visa (EMV) credit card functions are provided. EMV is a standard for integrated-chip based credit cards. The secure-key accelerator functions are targeted to improving the performance of Secure Sockets Layer (SSL) transactions. The #4764 provides the security and performance required to support eBusiness and emerging digital signature applications. Host application access to the cryptographic services of the #4764 are via the Common Cryptographic Architecture (CCA) application programming interfaces (APIs) or additionally via Public-Key Cryptographic Standards (PKCS#11) APIs. Only one API can be loaded on a single feature 4764 card.
The #4764 provides secure storage of cryptographic keys in a tamper resistant hardware security module (HSM), which is designed to meet FIPS 140 security requirements. FIPS 140 is a US Government National Institute of Standards & Technology (NIST) administered standard and certification program for cryptographic modules.
Feature 4764 PCI-X Cryptographic Coprocessor (FIPS 4) users will be able to down load firmware for AIX from the following URL replacing the firmware CD previously provided.
Notes: FC 4764 Firmware and support software are part of "AIX Expansion Pack and Web Download Pack"
Refer to the following URL for the latest firmware and software updates.
- Attributes provided:
- Cryptographic Accelerator Function
- EMV-Based Credit Card Function
- CCA API Host Support, and PKCS#11 API.
- Attributes required:
- One PCI-X card slot per 4764 FC.
Note: Only one API (CCA or PKCS11 but not both) can be loaded per 4764 Feature.
- One PCI-X card slot per 4764 FC.
- For 8205-E6D: (#4764)
- Minimum required: 0
- Maximum allowed: 48 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC.
- System maximum of 48 with 8 x #5796.
(#4794) - Power Active Memory Expansion Enablement
This feature enables memory expansion on the system. Using compression/decompression of memory content can effectively expand the maximum memory capacity providing additional server workload capacity and performance.
- Attributes provided: None
- Attributes required: An HMC
- For 8205-E6D: (#4794)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- AIX 6.1 supported
- AIX 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#4807) - PCIe Crypto Coprocessor No BSC 4765-001
(No Longer Available as of February 27, 2015)
Secure-key adapter provides both cryptographic coprocessor and cryptographic accelerator functions in a single PCIe card. The adapter is well suited to applications requiring high-speed, security- sensitive, RSA acceleration, cryptographic operations for data encryption and digital signing, secure management, and use of cryptographic keys, or custom cryptographic applications. It provides secure storage of cryptographic keys in a tamper-resistant hardware security module designed to meet FIPS 140-2 level 4 security requirements. The adapter is a PCIe 4x full height - short card.
#4807, #4808 and #4809 are all feature codes representing the same physical card with the same CCIN of 4765, but different feature codes are used to indicate if a blind swap cassette is used and its type. #4807 indicates no blind swap cassette. #4808 indicates a Gen 3 blind swap cassette. #4809 indicates a Gen 4 blind swap cassette.
Other IBM PCIe Cryptographic Coprocessor adapter highlights
- Integrated Dual processors that operate in parallel for higher reliability
- Supports IBM Common Cryptographic Architecture or PKCS#11 standard
- Ability to configure adapter as coprocessor or accelerator
- Support for smart card applications using Europay, MasterCard and Visa
- Cryptographic key generation and random number generation
- PIN processing - generation, verification, translation
- Encrypt/Dectrypt using AES and DES keys
Refer to the following URL for the latest firmware and software updates.
- Attributes provided: Cryptographic and Accelerator Function
- Attributes required: One PCIe Cryptographic CoProcessor card slot per adapter
- For 8205-E6D: (#4807)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 2)
- OS level required:
- AIX 7.1 supported
- AIX 6.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 2 #4807 per CEC
- The combined system maximum limit for #4807 and #4808 is 10.
- #4808 system maximum is 8 when there are no #4807s in the CEC.
- A maximum of 4 #4808s per #5802 or #5877.
- The PCIe Crypto Adapter #4807/08/09 can not be installed in the same AIX partition as the PCI-X Crypto Adapter #4764, but can be on the same server in a different partition.
(#4808) - PCIe Crypto Coprocessor Gen3 BSC 4765-001
(No Longer Available as of February 27, 2015)
Secure-key adapter provides both cryptographic coprocessor and cryptographic accelerator functions in a single PCIe card. The adapter is well suited to applications requiring high-speed, security- sensitive, RSA acceleration, cryptographic operations for data encryption and digital signing, secure management, and use of cryptographic keys, or custom cryptographic applications. It provides secure storage of cryptographic keys in a tamper-resistant hardware security module designed to meet FIPS 140-2 level 4 security requirements. The adapter is a PCIe 4x full height - short card.
#4807, #4808 and #4809 are all feature codes representing the same physical card with the same CCIN of 4765, but different feature codes are used to indicate if a blind swap cassette is used and its type. #4807 indicates no blind swap cassette. #4808 indicates a Gen 3 blind swap cassette. #4809 indicates a Gen 4 blind swap cassette.
Other IBM PCIe Cryptographic Coprocessor adapter highlights
- Integrated Dual processors that operate in parallel for higher reliability
- Supports IBM Common Cryptographic Architecture or PKCS#11 standard
- Ability to configure adapter as coprocessor or accelerator
- Support for smart card applications using Europay, MasterCard and Visa
- Cryptographic key generation and random number generation
- PIN processing - generation, verification, translation
- Encrypt/Decrypt using AES and DES keys
Refer to the following URL for the latest firmware and software updates.
- Attributes provided: Cryptographic Coprocessor and Accelerator Functions
- Attributes required: One PCIe Cryptographic CoProcessor card slot per adapter
- For 8205-E6D: (#4808)
- Minimum required: 0
- Maximum allowed: 8 (Initial order maximum: 8)
- OS level required:
- AIX 7.1 supported
- AIX 6.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Not supported in the CEC.
- Maximum of 2 #4807 per CEC
- The combined system maximum limit for #4807 and #4808 is 10.
- #4808 system maximum is 8 when there are no #4807s in the CEC.
- A maximum of 4 #4808 per #5802 or #5877.
- The PCIe Crypto Adapter #4807/08/09 can not be installed in the same AIX partition as the PCI-X Crypto Adapter #4764, but can be on the same server in a different partition.
(#4929) - Power 740 Solution Edition for IBM i
(No Longer Available as of November 30, 2015)
This feature defines to the configurator a select minimum configuration for a Power 740 offering.
- Attributes provided: Solution Edition for IBM i
- Attributes required: None
- For 8205-E6D: (#4929)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#4970) - One Processor of 5250 Enterprise Enablement
This feature will activate one processor's worth of 5250 Enterprise Enablement in an IBM i environment.
- Attributes provided: Single 5250 Enterprise Enablement
- Attributes required: None
- For 8205-E6D: (#4970)
- Minimum required: 0
- Maximum allowed: 16 (Initial order maximum: 16)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#4973) One Processor of 5250 Enterprise Enablement for Solution Edition
(No Longer Available as of November 30, 2015)
This feature will activate one processor's worth of 5250 Enterprise Enablement in an IBM i environment. Only available with the Power 740 Solution Edition (#4972 or #4929).
- Attributes provided: Single 5250 Enterprise Enablement
- Attributes required: Power 740 Solution Edition for IBM i (Feature #4972 or #4929))
- For 8205-E6D: (#4973)
- Minimum required: 0
- Maximum allowed: 16 (Initial order maximum: 16)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#4974) - Full 5250 Enterprise Enablement
This feature will fully activate 5250 Enterprise Enablement in an IBM i environment.
- Attributes provided: Full 5250 Enterprise Enablement
- Attributes required: IBM i environment
- For 8205-E6D: (#4974)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#5000) - Software Preload Required
(No Longer Available as of November 30, 2015)
Indicates that preloaded software and/or consolidated I/O is shipped with the initial order. A maximum of one (#5000) is supported. This feature has country-specific usage.
- Attributes provided: Software Pre-load
- Attributes required: N/A
- For 8205-E6D: (#5000)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#5160) - Power Dist Unit 1 Phase NEMA
This feature provides a single phase NEMA PDU for 19 inch Racks. Each PDU provides six outlets.
System units and/or expansion units would use a #6458 line cord to connect to the #5160.
The following line cords are supported on the #5160:
- #1424 - 200V 6-Ft Locking Line Cord (supported, not orderable)
- #1425 - 200V 6-Ft Wtrtght Line Cord (supported, not orderable)
- #1426 - 200V 14-Ft Locking Line Cord
- #1427 - 200V 14-Ft Wtrtght Line Cord
- #1446 - 4.3m 200V/30A Pwr Cd Korea
- #1447 - 4.3m 200V/30A Pwr Cd AU
- #1448 - 4.3m 200V/30A Pwr Cd NZ (supported, not orderable)
- Attributes provided: Power Distribution Unit
- Attributes required: 19 Inch Rack
- For 8205-E6D: (#5160)
- Minimum required: 0
- Maximum allowed: 192 (Initial order maximum: 0)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5161) - Power Dist Unit 1 Phase IEC
This feature provides a single phase IEC PDU for iSeries racks. Each PDU provides six outlets.
System units and/or expansion units would use a #6458 line cord to connect to the #5161.
The following line cord is supported on the #5161:
- #1449 - 4.3m 200V/32A Pwr Cd EU 1-PH
- Attributes provided: Power Distribution Unit
- Attributes required: 19 Inch Rack
- For 8205-E6D: (#5161)
- Minimum required: 0
- Maximum allowed: 192 (Initial order maximum: 0)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5162) - Power Dist Unit 2 of 3 Phase
This feature provides a 2 of 3 phase Power Distribution Unit (PDU) for iSeries Racks. Each PDU provides six outlets.
The following line cord is supported on the #5162:
- #1450 - 4.3m 200V/16A Pwr Cd EU 2-PH (supported, not orderable)
- Attributes provided: Power Distribution Unit
- Attributes required: 19 Inch Rack
- For 8205-E6D: (#5162)
- Minimum required: 0
- Maximum allowed: 192 (Initial order maximum: 0)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5163) - Power Dist Unit - 3 Phase
This feature provides a 3 phase Power Distribution Unit (PDU) for iSeries Racks. Each PDU provides six outlets.
System units and/or expansion units would use a #6458 line cord to connect to the #5163.
The following line cord is supported on the #5163:
- #1477 - 4.3m 200V/16A PWR CD
- Attributes provided: Power Distribution Unit
- Attributes required: 19 Inch Rack
- For 8205-E6D: (#5163)
- Minimum required: 0
- Maximum allowed: 192 (Initial order maximum: 0)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5225) - PowerVM Express Edition
(No Longer Available as of August 1, 2014)
This feature allows the customer to create up to 3 logical partitions of any size in a system, which share processors and I/O. This feature does not require an HMC. PowerVM Express may be managed by the Integrated Virtualization Manager (IVM). This feature allows users to try out the IVM and the VIOS, which they would not get with an HMC. Note: If feature 5225 is ordered, the quantity ordered must be equal to the number of active processors.
- Attributes provided: Capability to partition processor
- Attributes required: None
- For 8205-E6D: (#5225)
- Minimum required: 0
- Maximum allowed: 16 (Initial order maximum: 16)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#5227) - PowerVM Standard Edition
This feature allows the customer to create partitions that are in units of less than 1 CPU (sub-CPU LPARs) and allows the same system I/O to be virtually allocated to these partitions. When PowerVM is installed in the system, all activated processors must have the PowerVM feature. A fully activated 4-core system requires that four of this feature be ordered. An encrypted key is supplied to the customer and is installed on the system, authorizing the partitioning at the sub-processor level. Note: If feature 5227 is ordered, the quantity ordered must be equal to the number of active processors.
- Attributes provided: Capability to partition processor
- Attributes required: None
- For 8205-E6D: (#5227)
- Minimum required: 0
- Maximum allowed: 16 (Initial order maximum: 16)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#5228) - PowerVM Enterprise Edition
This feature allows the customer to create partitions that are in units of less than 1 CPU (sub-CPU LPARs) and allows the same system I/O to be virtually allocated to these partitions. When PowerVM is installed in the system, all activated processors must have the PowerVM feature. A fully activated 4-core system requires that four of this feature be ordered. An encrypted key is supplied to the customer and is installed on the system, authorizing the partitioning at the sub-processor level. PowerVM Enterprise Edition also includes Live Partition Mobility, which allows for the movement of a logical partition from one POWER7 server to another with no application downtime. Note: If feature 5228 is ordered, the quantity ordered must be equal to the number of active processors.
- Attributes provided: Capability to partition processor
- Attributes required: None
- For 8205-E6D: (#5228)
- Minimum required: 0
- Maximum allowed: 16 (Initial order maximum: 16)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#5260) - PCIe2 LP 4-port 1GbE Adapter
(No Longer Available as of March 31, 2018)
This short PCIe Gen2 adapter provides four 1Gb Ethernet ports that can be configured to run at 1000, 100 or 10 Mbps. 4-pair CAT-5 Unshielded Twisted Pair (UTP) cables up to 100 meters in length are attached to the copper RJ45 connectors. Each port is independent of one another and supports full-duplex or half-duplex. 1000 Mbps speed is not supported in Half Duplex (HDX) mode.
Feature #5260 and #5899 are electronically identical and have the same CCIN of 576F. #5260 indicates a low profile tail stock while #5899 indicates a full high tail stock.
Details for the ports include:
- AIX NIM support
- IEEE 802.3ab (1 GbE), 802.1p priority, 802.1Q VLAN tagging, 802.3x flow control, 802.3ad load-balancing and failover,
- Link aggregation, IEEE 802.3ad 802.3
- Multiple MAC addresses per interface
- MSI-X, MSI and support of legacy pin interrupts
- Ether II and IEEE 802.3 encapsulated frames
- Jumbo frames up to 9.6 Kbytes
- TCP checksum offload for IPv4 and IPv6
- TCP segmentation Offload (TSO) for IPv4 and IPv6
- UDP checksum offload for IPv4 and IPv6
- AIX, IBM i and Linux provide software iSCSI support through the adapter. Linux can also leverage adapter hardware support including initiator and header & data digest (CRC) generation and checking
- Attributes provided: Four-port 1 Gb Ethernet
- Attributes required: 1 Low Profile (LP) PCIe slot (Gen1 or Gen2)
- For 8205-E6D: (#5260)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#5269) - PCIe LP POWER GXT145 Graphics Accelerator
(No Longer Available as of March 31, 2018)
This feature is the Low Profile (LP) equivalent of feature number 5748. The POWER GXT145 is a versatile, low-priced 2D graphics accelerator. It can be configured to operate in either 8-bit or 24-bit color modes. This adapter supports both analog and digital monitors. The adapter requires a PCI Express slot. If attaching a device that requires a 15 pin D-Shell receptacle for a VGA connection (eg. when the graphic adapter output is routed directly to a 7316-TF3 display or indirectly through a KVM switch), order a VGA to DVI Connection Converter, feature number 4276 to accommodate the attaching device. A short converter cable is included which adapts the 2nd 28-pin port on the adapter to 15-pin D-Shell receptacle.
- Hardware Description
- 128-bit graphics processor
- 8-bit indexed, 8-bit true color, or 24-bit true color
- 32 MB SDRAM
- x1 PCI Express interface
- 2 DVI-I (analog/digital video) connectors
- 1 converter cable
- Features Supported
- Up to approximately 16.7 million colors
- Rectangular clipping
- 1 monitor connected analog at up to 2048 x 1536 resolution
- 1 monitor connected digital at up to 1280 x 1024 resolution
- 2nd monitor supported on secondary connecter at up to 1600 x 1200 analog or 1280 x 1024 digital
- 2nd monitor support in AIX is only in clone mode with an analog connection
- APIs Supported
- X-Windows and Motif
- Software Requirements
- The total number of graphics adapters in any one partition may not exceed four.
- Attributes provided: 2D Graphics Adapter
- Attributes required: 1 Low Profile (LP) slot
- For 8205-E6D: (#5269)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 4 supported in the CEC with #5685 installed.
(#5270) - PCIe LP 10Gb FCoE 2-port Adapter
(No Longer Available as of January 22, 2016)
This feature is the Low Profile (LP) equivalent of feature number 5708. 10 Gb FCoE PCIe Dual Port Adapter (#5708/5270) is a high- performance, 10 Gb, dual port, PCIe Converged Network Adapter (CNA) utilizing SR optics. Each port can provide NIC (Network Interface Card) traffic and Fibre Channel functions simultaneously. CCIN is 2B3B
Highlights
- PCIe 2.0 adapter with x8 Gen 1
- Convergence Enhanced Ethernet (CEE) supported
- SR optical transceiver with LC connection provides up to 300m cable length
- Non-volatile error log on the adapter
- Supported with AIX and Linux and VIOS for FC and Ethernet NIC.
- Supported with IBM i under VIOS for FC and Ethernet NIC
- SAN and Network boot support for AIX, Linux
- Requires FCoCEE capable switches for full FC+Ethernet capability. Ethernet only functionality if attached to ordinary Ethernet switch.
- Utilizes existing cabling that supports 10 Gb SR
- Based on the QLogic Converged Network Adapter (CNA)
- NPIV support requires VIOS for all OS environments
Configuration maximum when used for NIC traffic (not Fibre Channel usage)
- Recommended performance Max assuming high utilization, One adapter per four active processors cores.
- Recommended connectivity Max assuming high utilization, two adapters per one physical processor core.
- Attributes provided: 10Gb FCoE PCIe Dual Port Adapter (LP)
- Attributes required: 1 Low Profile (LP) slot
- For 8205-E6D: (#5270)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 4 supported in the CEC with #5685 installed.
(#5271) - PCIe LP 4-Port 10/100/1000 Base-TX Ethernet Adapter
(No Longer Available as of January 1, 2014)
This is the Low Profile (LP) equivalent of feature number 5717. The 4-Port 10/100/1000 Base-TX PCI Express Adapter is short/ low- profile, full duplex, four-ported Gigabit Ethernet adapter that can be configured to run any of the ports at 1000,100 or 10 Mbps data rate. This adapter interfaces to the system via a PCIe bus and connects to a network using a 4-pair CAT-5 Unshielded Twisted Pair (UTP) cable for distance of up to 100m. Each port is independent of one another and is boot capable under AIX Network install manager (NIM). The adapter conforms to the IEEE 802.3ab 1000Base-T standard. The #5717 supports jumbo frames when running at the 1000 Mbps speed.
The 4-Port 10/100/1000 Base-TX PCI Express adapter (#5717) should be considered where maximum port density is required per I/O card slot. For a suggested maximum number of adapters considering performance, see the IBM System p PCI placement guide (SA76-0090) for information about the PCIe slots on your system unit.
Limitations: The 1000 Mbps speed is not supported in Half Duplex (HDX) mode.
- Attributes provided: Four-port Gigabit Ethernet
- Attributes required: 1 Low Profile (LP) slot
- For 8205-E6D: (#5271)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 4 supported in the CEC with #5685 installed.
(#5272) - PCIe LP 10GbE CX4 1-port Adapter
(No Longer Available as of July 19, 2013)
This feature is the Low Profile (LP) equivalent of feature number 5732. The 10 Gigabit Ethernet-CX4 PCI Express Adapter is a low profile high performance adapter that transfers data over 4-lanes in each direction over copper cabling supporting a distance up to 15m.The product conforms to the IEEE, 802.3ak 10GBASE-CX4 specification for Ethernet transmission.
Highlights:
- Implements iWARP RDMA/RDDP (Remote Direct Data Placement) which adheres to IETF (Internet Engineering Task Force) standards. (Linux Only)
- RDMA-enabled NIC (RNIC) specifically optimized for cluster computing (Linux Only)
Full iSCSI software and hardware initiator support. (Linux Only)
- Hardware PDU Offload (Linux Only)
- iSCSI Header & Data Digest (CRC) generation & checking ( Linux Only)
Attributes provided:
- PCIe-V1.1 x8
- MSI-X, MSI and support of legacy pin interrupts
- 10GBASE-CX short-reach copper
- IEEE 802.3ae (10 GbE)
- IEEE 802.1p priority and 802.1Q VLAN tagging
- IEEE 802.3x flow control
- Link aggregation, 802.3ad 802.3 compliance
- IEEE 802.3ad load-balancing and failover
- Ether II and 802.3 encapsulated frames
- Multiple MAC addresses per interface
- Jumbo frames up to 9.6 Kbytes
- TCP checksum offload for IPv4 and IPv6
- TCP segmentation Offload (TSO) for IPv4 and IPv6
- UDP checksum offload for IPv4 and IPv6
- Receive side scaling and packet steering
- Line rate packet filtering and attack protection
- IETF RDDP and RDMAC iWARP compliance (Linux Only)
- APIs: RNIC-PI, kDAPL and Open Fabrics Enterprise Distribution(OFED) 1.4 (Linux Only)
- Attributes provided: PCI-e-V1.1 x8 Ethernet
- Attributes required: 1 Low Profile (LP) slot
- For 8205-E6D: (#5272)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 4 supported in the CEC with #5685 installed.
(#5273) - PCIe LP 8Gb 2-Port Fibre Channel Adapter
(No Longer Available as of March 31, 2018)
This feature is the Low Profile (LP) equivalent of feature number 5735.
The 8 Gigabit PCI Express Dual Port Fibre Channel Adapter is a high-performance 8x short form adapter based on the Emulex LPe12002 PCIe Host Bus Adapter (HBA). Each port provides single initiator capability over a fibre link. The ports have LC type connectors and utilize shortwave laser optics. The adapter operates at link speeds of 2, 4, and 8 Gbps and will automatically negotiates to the highest speed possible. LEDs on each port provide information on the status and link speed of the port.
The adapter connects to a Fibre Channel switch (AIX, IBM i, Linux,VIOS). If in an IBM i environment, devices can also be directly attached.
N_Port ID Virtualization (NPIV) capability is supported through VIOS.
Cables are the responsibility of the customer. Use multimode fibre optic cables with short-wave lasers that adhere to the following specifications:
OM3 - multimode 50/125 micron fibre, 2000 MHz*km bandwidth
OM2 - multimode 50/125 micron fibre, 500 MHz*km bandwidth
OM1 - multimode 62.5/125 micron fibre, 200 MHz*km bandwidth
Because core sizes are different, OM1 cables can only be connected to other OM1 cables. For best results, OM2 cables should not be connected to OM3 cables. However, if an OM2 cable is connected to an OM3 cable, the characteristics of the OM2 cable apply to the entire length of the cables.
The following table shows the supported distances for the three different cable types at the three different link speeds.
Cable 2.125 Gbps 4.25 Gbps 8.5 Gbps
------ ------------ ----------- -----------
OM3 .5m - 500m .5m - 380m .5m - 150m
OM2 .5m - 300m .5m - 150m .5m - 50m
OM1 .5m - 150m .5m - 70m .5m - 21m
See also optional wrap plug feature #ECW0 which is:
- a) Required to run some diagnostic procedures and
- b) in some cases may speed system boot when placed in empty ports as well as avoid useless messages pointing to a planned empty port.
- Attributes provided: Dual port fibre channel
- Attributes required: 1 Low Profile (LP) slot
- For 8205-E6D: (#5273)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 4 supported in the CEC with #5685 installed.
(#5274) - PCIe LP 2-Port 1GbE SX Adapter
(No Longer Available as of December 29, 2017)
This feature is the Low Profile (LP) equivalent of feature number 5768. The IBM 2-Port Gigabit Ethernet-SX PCI Express (PCIe) Adapter provides two 1 Gbps (1000 Base-SX) full-duplex Ethernet LAN connections. The adapter interfaces to the system via a PCIe bus. It is PCIe x4 capable and conforms to the PCIe 1.0a standard. The adapter connects to a network using a 50/62.5 micron shortwave (850 nm) multimode optical cable that conforms to the IEEE 802.3z standard. The adapter supports distances of 260m for 62.5 micron Multi Mode Fiber (MMF) and 550m for 50.0 micron MMF. AIX Network Install Manager (NIM) boot capability is supported with this adapter.
A function called 'Large Send' or sometimes known as TCP Segmentation is also provided by this adapter. This function offloads the TCP segmentation operation from the AIX IP layer to the adapter for outgoing (transmit side) TCP segments. Another function known as "Checksum Offload" which offloads the TCP Checksum Operation or workload from the CPU to the adapter is also provided.
For a suggested maximum number of adapters taking performance into consideration, see the IBM System p PCI placement guide (SA76-0090) for information about the PCIe slots on your system unit.
Note: The 2-Port IBM Gigabit Ethernet-SX PCIe Adapter incorporates an LC type connector on the card. This new, smaller form factor connector is being used by the industry for the next generation of fiber optic networks. If connecting into an older, existing SC type connector network, an LC-SC 62.5 Micron Fiber Converter Cable (#2459) or LC-SC 50 Micron Fiber Converter Cable (#2456) is required.
Limitation: Half Duplex (HDX) mode is not supported.
- Attributes provided: Two full-duplex 1000Base-SX fibre connections to Gigabit Ethernet LAN(s)
- Attributes required: 1 Low Profile (LP) slot
- For 8205-E6D: (#5274)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 4 supported in the CEC with #5685 installed.
(#5275) - PCIe LP 10GbE SR 1-port Adapter
(No Longer Available as of July 14, 2017)
This feature is the Low Profile (LP) equivalent of feature number 5769. The 10 Gigabit Ethernet-SR PCI Express Adapter is a low- profile, high performance adapter that uses a LC Duplex type connector and is capable of transferring data a distance of 300m over MMF-850nm Fiber cable. The product conforms to the IEEE, 802.3ae 10GBASE-SR specification for Ethernet transmission.
Highlights
- Implements iWARP RDMA/RDDP (Remote Direct Data Placement) which adheres to IETF (Internet Engineering Task Force) standards. (Linux Only)
- RDMA-enabled NIC (RNIC) specifically optimized for cluster computing (Linux Only)
- Full iSCSI initiator and target mode stack (Linux Only)
- iSCSI Header & Data Digest (CRC) generation & checking (Linux Only)
- PDU recovery (Linux Only)
Attributes
- MSI-X, MSI and support of legacy pin interrupts
- 10GBASE-SR short-reach optics
- IEEE 802.3ae (10 GbE)
- IEEE 802.1p priority and 802.1Q VLAN tagging
- IEEE 802.3x flow control
- Link aggregation, 802.3ad 802.3 compliance
- IEEE 802.3ad load-balancing and failover
- Ether II and 802.3 encapsulated frames
- Multiple MAC addresses per interface
- Jumbo frames up to 9.6 Kbytes
- TCP checksum offload for IPv4 and IPv6
- TCP segmentation Offload (TSO) for IPv4 and IPv6
- UDP checksum offload for IPv4 and IPv6
- Receive side scaling and packet steering
- Line rate packet filtering and attack protection
- IETF RDDP and RDMAC iWARP compliance (Linux Only)
- APIs: RNIC-PI, kDAPL and OpenFabrics 1.4 (Linux Only)
- Attributes provided: PCIe-V1.1 x8 10GBASE-SR short-reach optics adapter (LP)
- Attributes required: 1 Low Profile (LP) slot
- For 8205-E6D: (#5275)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 4 supported in the CEC with #5685 installed.
(#5276) - PCIe LP 4Gb 2-Port Fibre Channel Adapter
(No Longer Available as of March 31, 2018)
This feature is the Low Profile (LP) equivalent of feature number 5774. The 4 Gigabit Dual Port Fibre Channel Adapter is a 64-bit address/data, short form factor PCIe adapter with an LC type external fiber connector. With the use of appropriate optical fiber cabling, this adapter provides the capability for a network of high-speed local and remote located storage. The adapter will auto-negotiate for the highest data rate between adapter and an attaching device at 1 Gbps, 2 Gbps or 4 Gbps of which the device or switch is capable. Between the adapter and an attaching device or switch, the distances supported are up to: 500 meters running at 1 Gbps data rate, 300 meters running at 2 Gbps data rate, and 150 meters running at 4 Gbps data rate. When used with IBM Fibre Channel storage switches supporting long-wave optics, distances of up to 10 kilometers are capable running at either 1 Gbps, 2 Gbps, or 4 Gbps data rates.
The 4 Gigabit PCIe Dual Port Fibre Channel Adapter can be used to attach devices either directly, or by means of Fibre Channel Switches. If attaching a device or switch with a SC type fiber connector(s), use of an LC-SC 50 Micron Fiber Converter Cable (#2456) or a LC-SC 62.5 Micron Fiber Converter Cable (#2459) is required.
Refer to the following IBM storage subsystem web page for additional supported server attachment information for IBM devices.
Consult with your IBM representative or Business Partner for additional information relative to any third party attachment.
See also optional wrap plug feature #ECW0 which is:
- a) Required to run some diagnostic procedures and
- b) in some cases may speed system boot when placed in empty ports as well as avoid useless messages pointing to a planned empty port.
- Attributes provided: Dual-port Fibre channel
- Attributes required: 1 Low Profile (LP) slot
- For 8205-E6D: (#5276)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 4 supported in the CEC with #5685 installed.
(#5277) - PCIe LP 4-Port Async EIA-232 Adapter
(No Longer Available as of March 31, 2018)
This feature is the Low Profile (LP) equivalent of feature number 5785. One connector on the rear of the adapter provides attachment for a fan-out cable (provided) which provides four EIA-232 ports. Note #5785 and #5277 are physically and electrically identical adapters, except for the type of PCIe slot used (full-high or low profile). Note also the 4-port #5277/5785 is functionally nearly identical to the 2-port #5289/5290 except for the number and type of connectors.
- Attributes provided: 4-Port Asynchrous EIA-232 via 4-Port DB9 DTE Fan-Out Cable 1.2 M (4 ft.), 4 x 9-pin D-Sub (Male DB-9) and 1 x 68-pin D-Sub (HD-68)
- Attributes required: 1 Low Profile (LP) slot
- For 8205-E6D: (#5277)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- IBM i 7.1 TR11, or later
- IBM i 7.2 TR4, or later
- IBM i 7.3, or later
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 4 supported in the CEC with #5685 installed.
(#5278) - PCIe LP 2-x4-port SAS Adapter 3 Gb
(No Longer Available as of March 31, 2018)
This feature is the Low Profile (LP) equivalent of feature number 5901. The #5901/5278 PCIe Dual-4x SAS Adapter is a low-profile short form factor adapter which supports the attachment of SAS disk, tape, and DVD using a pair of mini SAS 4x connectors. From a high level perspective, it is functionally equivalent to the #5912 PCI-X SAS adapter and provides a high-performance connection to SAS devices.
The #5901/5278 supports external SAS tape drives such as the 36/ 72 GB DAT72, 80/160 GB DAT160, and 800/1600 GB LTO-4 found in the IBM tape units such as the 7214-1U2, TS2240, TS2340, TS3100, TS3200, and TS3310. Other removable media devices supported include IBM SAS/SATA DVD-ROM/RAM drives. SAS adapter-to-enclosure (AE) cables are used to attach these drives.
The #5901/5278 supports SAS SFF disk drives located in a PCIe 12X I/O Drawer or SAS disk drives located in an EXP 12S Disk Drawer or drives in a POWER6 or POWER7 system CEC (split DASD backplane). AIX/ Linux formatted SAS drives are supported with RAID 0 (with mirroring) and RAID 10. IBM i formatted SAS drives are supported and data spreading and mirroring functions are provided by IBM i. RAID-5 or RAID-6 are not supported on the #5901/5278. #5901/5278 has zero write cache. CCIN for #5901/5278 is 57B3.
With proper cabling and configuration, multiple wide ports are used to provide redundant paths to each dual port SAS disk . The adapter manages SAS path redundancy and path switching should a SAS drive failure occur. SAS Y cables attach SAS disk drives in an EXP 12S Disk Drawers. SAS #3688 cables attach SFF SAS drives in an PCIe 12X I/O Drawer. In the EXP 12S Drawer, a high availability I/O configuration can be created using a pair of #5901, a pair of 5278 or a paired 5901/5278 adapters and SAS X cables to protect against the failure of a SAS adapter. In the PCIe 12X I/O Drawer, this function is provided via the internal wiring within the drawer itself.
Limitation: 4k byte sector HDD/SSD are not supported. Only 5xx byte sector drives are supported on this generation of PCIe adapter.
Highlights:
- Supports up to 48 SAS disks, when configured with four #5886 EXP 12S Disk Drawers
- Supports up to 42 disk (18 SFF disk plus up to 24 3.5-inch SAS disk) when configured with a #5802 19-inch PCIe 12X I/O Drawer and two #5886 EXP 12S Disk Drawers
- Supports up to 50 disk (26 SFF disk plus up to 24 3.5-inch SAS disk) when configured with a #5803 24-inch PCIe 12X I/O Drawer and two #5886 EXP 12S Disk Drawers
- SAS speed = 3 Gbs
- SATA speed = 1.5 Gbs
- SAS Serial SCSI Protocol (SSP), Serial ATA Tunneling Protocol (STP) and Serial Management Protocol (SMP)
- Dual controller supports mirrored RAID parity footprints
- Concurrent firmware update
- Attributes provided: Eight physical links via two mini SAS 4x connectors
- Attributes required: 1 Low Profile (LP) slot
- For 8205-E6D: (#5278)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 4 supported in the CEC with #5685 installed.
(#5279) - PCIe2 LP 4-Port 10GbE&1GbE SFP+ Copper&RJ45
(No Longer Available as of April 23, 2017)
This PCIe Gen2 Ethernet adapter provides two 10 Gb copper SFP+ ports and two 1 Gb RJ45 ports.
For the 10Gb ports, active copper twinax cables up to 5 meter in length have been tested and are supported. See feat code #EN01 (1m), #EN02 (3m) and #EN03 (5m). Note that SFP+ twinax copper is NOT AS/ 400 5250 twinax or CX4 or 10 GBASE-T and note passive cables are NOT supported.
For the 1Gb RJ45 ports, 4-pair CAT-5 Unshielded Twisted Pair (UTP) cable or higher is supported for distances of up to 100 meters. In addition to 1Gb (1000 Mb) networks, 100 Mb networks are also supported, but 10Mb networks are not supported.
Note #5745 and #5279 adapters are physically and electronically identical except for their low profile or full high PCI slot attribute.
Highlights
- Implements iWARP RDMA/RDDP (Remote Direct Data Placement) which adheres to IETF (Internet Engineering Task Force) standards. (Linux and 10 Gb port Only)
- RDMA-enabled NIC (RNIC) specifically optimized for cluster computing (Linux and 10 Gb port Only)
- Full iSCSI initiator and target mode stack (Linux and 10 Gb port Only)
- iSCSI Header & Data Digest (CRC) generation & checking (Linux and 10 Gb port Only)
- PDU recovery (Linux and 10 Gb port Only)
Attributes
- MSI-X, MSI and support of legacy pin interrupts
- 10GBASE-CR
- EEE 802.3ae (10 GbE)
- IEEE 802.3ab (1 GbE)
- IEEE 802.1p priority and 802.1Q VLAN tagging
- IEEE 802.3x flow control
- Link aggregation, 802.3ad 802.3 compliance
- IEEE 802.3ad load-balancing and failover
- Ether II and 802.3 encapsulated frames
- Multiple MAC addresses per interface
- Jumbo frames up to 9.6 Kbytes
- TCP checksum offload for IPv4 and IPv6
- TCP segmentation Offload (TSO) for IPv4 and IPv6
- UDP checksum offload for IPv4 and IPv6
- IETF RDDP and RDMAC iWARP compliance (Linux and 10 Gb port Only)
- APIs: RNIC-PI, kDAPL and OpenFabrics 1.4 (Linux and 10 Gb port Only)
Homologation:
This feature is not certified for connection by any means whatsoever to interfaces of public telecommunications networks. Certification may be required by law prior to making any such connection. Contact an IBM representative or reseller for any questions.
Limit:
This feature may not be assigned to a VIOS partition and thus LPAR Mobility operations are not supported with this feature.
- Attributes provided: Two 1 Gb and Two 10Gb Ethernet ports
- Attributes required: One available Low Profile (LP) PCIe Gen 2 slot and under Linux environment, active copper twinax cables, twinax wrap plugs.
- For 8205-E6D: (#5279)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 4 supported in the CEC with #5685 installed.
(#5280) - PCIe2 LP 4-Port 10GbE&1GbE SR&RJ45 Adapter
(No Longer Available as of February 23, 2017)
This PCIe Gen2 Ethernet adapter provides two 10 Gb SFP+ SR optical transceiver ports and two 1 Gb RJ45 ports. This is a low profile adapter.
For the 10Gb ports, LC Duplex type connectors and MMF-850nm fiber cable are used. With 62.5 micron OM1, up to 33 meter length fiber cables are supported. With 50 micron OM2, up to 82 meter fiber cable lengths are supported. With 50 micron OM3, up to 300 meter fiber cable lengths are supported.
For the 1Gb RJ45 ports, The RJ45 port, 4-pair CAT-5 Unshielded Twisted Pair (UTP) cable or higher is supported for distances of up to 100 meters is supported. In addition to 1Gb (1000 Mb) networks, 100 Mb networks are also supported, but 10Mb networks are not supported.
Note #5744 and #5280 adapters are physically and electronically identical except for their low profile or full high PCI slot attribute.
Highlights
- Implements iWARP RDMA/RDDP (Remote Direct Data Placement) which adheres to IETF (Internet Engineering Task Force) standards. (Linux and 10 Gb port Only)
- RDMA-enabled NIC (RNIC) specifically optimized for cluster computing (Linux and 10 Gb port Only)
- Full iSCSI initiator and target mode stack (Linux and 10 Gb port Only)
- iSCSI Header & Data Digest (CRC) generation & checking (Linux and 10 Gb port Only)
- PDU recovery (Linux and 10 Gb port Only)
Attributes
- MSI-X, MSI and support of legacy pin interrupts
- 10GBASE-SR short-reach optics
- IEEE 802.3ae (10 GbE)
- IEEE 802.3ab (1 GbE)
- IEEE 802.1p priority and 802.1Q VLAN tagging
- IEEE 802.3x flow control
- Link aggregation, 802.3ad 802.3 compliance
- IEEE 802.3ad load-balancing and failover
- Ether II and 802.3 encapsulated frames
- Multiple MAC addresses per interface
- Jumbo frames up to 9.6 Kbytes
- TCP checksum offload for IPv4 and IPv6
- TCP segmentation Offload (TSO) for IPv4 and IPv6
- UDP checksum offload for IPv4 and IPv6
- IETF RDDP and RDMAC iWARP compliance (Linux and 10 Gb port Only)
- APIs: RNIC-PI, kDAPL and OpenFabrics 1.4 (Linux and 10 Gb port Only)
Homologation:
This feature is not certified for connection by any means whatsoever to interfaces of public telecommunications networks. Certification may be required by law prior to making any such connection. Contact an IBM representative or reseller for any questions.
- Attributes provided: PCIe-V1.1 x8 10GBASE-SR short -reach optics adapter
- Attributes required: 1 PCI Express slot Low Profile (LP), Fiber Cable (Optional LC-SC 62.5 micron converter cable, 50 micron LC-SC connections), LC wrap plug-d
- For 8205-E6D: (#5280)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 4 supported in the CEC with #5685 installed.
(#5281) - PCIe LP 2-Port 1GbE TX Adapter
The IBM PCIe LP 2-Port 1GbE TX Adapter is a Full Duplex, dual ported, Gigabit Ethernet adapter designed with highly integrated components. This adapter can be configured to run each port at 10, 100, or 1000 Mbps data rates. The adapter interfaces to the system via a PCIe bus. It is PCIe x4 capable and conforms to the PCIe 1.0a standard. The adapter connects to a network using a 4-pair CAT-5 Unshielded Twisted Pair (UTP) cable for distances of up to 100m. AIX Network Install Manager (NIM) boot capability is supported with this adapter. The adapter conforms to the IEEE 802.3ab 1000Base-T standard. The adapter also supports jumbo frames when running at the 1000 Mbps speed.
A function called 'Large Send' or sometimes known as TCP Segmentation is also provided by this adapter. This function offloads the TCP segmentation operation from the AIX IP layer to the adapter for outgoing (transmit side) TCP segments. Another function known as "Checksum Offload" offloads the TCP Checksum Operation or workload from the CPU to the adapter is also provided.
The IBM 2-Port 10/100/1000 Base-TX Ethernet PCIe Adapter (#5281) should be considered where maximum port density is required per I/O card slot. For a suggested maximum number of adapters taking performance into consideration, see the IBM System p PCI placement guide (SA76-0090) for information about the PCIe slots on your system unit. The adapter is the same as 5767 and CINN.
Limitations: The 1000 Mbps speed is not supported in Half Duplex (HDX) mode.
- Attributes provided: Two full-duplex 10/100/1000Base-TX UTP connections to Gigabit Ethernet LAN(s).
- Attributes required: One available PCIe card slot
- For 8205-E6D: (#5281)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Maximum of 4 supported in the CEC with #5685 installed.
- VIOS 2.2, or later.
(#5283) - PCIe2 LP 2-Port 4X IB QDR Adapter 40Gb
(No Longer Available as of January 20, 2017)
The PCIe Gen-2 low profile 2-port 4X Infiniband QDR adapter provides high speed connectivity with other servers or IB switches. Each port maximum of 40Gb assumes no other system or switch bottlenecks are present. The adapters provide two QSFP+ cages, but does not include any transceivers. QSFP+ transceivers are included and permanently attached at each end of the following QDR IB cables: Copper 1m, 3m, 5m (#3287, #3288, and 3289) and Optical 10m, 30m (#3290, #3293).
Note: A PCIe Gen2 slot does not have the bandwidth to support two 40Gb ports. The benefit of the second 40Gb port is additional attachment redundancy, not performance. Also note: AIX supports multiple types of adapter usages across different applications and adapter performance should generally meet or exceed client needs. But when using TCP/IP, some AIX clients may observe less than full unidirectional link bandwidth and less than linear scaling for duplex bandwidth with the #5283.
- Attributes provided: PCIe2 LP 2-Port 4X IB QDR Adapter 40Gb
- Attributes required: PCIe Gen2 low profile slot
- For 8205-E6D: (#5283)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 2)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 2 supported in the CEC with #5685 installed.
(#5284) - PCIe2 LP 2-port 10GbE SR Adapter
(No Longer Available as of January 6, 2015)
The PCIe2 2-port 10GbE SR Adapter is a low-profile capable, high performance adapter that uses a LC Duplex type connector and is capable of transferring data a distance of 300m over MMF-850nm Fiber cable. The product conforms to the IEEE, 802.3ae 10GBASE-SR specification for Ethernet transmission.
Characteristics
- MSI-X and support of legacy pin interrupts
- 10GBASE-SR short-reach optics
- IEEE 802.3ae (10 GbE)
- IEEE 802.1p priority and 802.1Q VLAN tagging
- IEEE 802.3x flow control
- Link aggregation, 802.3ad 802.3 compliance
- IEEE 802.3ad load-balancing and failover
- Ether II and 802.3 encapsulated frames
- Multiple MAC addresses per interface
- Jumbo frames up to 9.6 Kbytes
- TCP checksum offload for IPv4
- TCP segmentation Offload (TSO) for IPv4
- UDP checksum offload for IPv4
- Receive side scaling and packet steering
- Line rate packet filtering and attack protection
- Attributes provided: PCIe-gen 2.0 x8 10GBASE-SR short-reach optics adapter
- Attributes required: 1 Low Profile Gen2 (LP) slot, Fiber Cable (Optional LC-SC 62.5 micron converter cable, 50 micron LC-SC connections), LC wrap plug-d
- For 8205-E6D: (#5284)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported only with VIOS
- IBM i 7.1 supported only with VIOS
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 4 supported in the CEC with #5685 installed.
- Note the #5284 and #5287 adapters are physically identical except for their tail stock - #5284= low profile and #5287= full high
(#5285) - PCIe2 2-Port 4X IB QDR Adapter 40Gb
(No Longer Available as of January 20, 2017)
The PCIe Gen-2 2-port 4X Infiniband QDR adapter provides high speed connectivity with other servers or IB switches. Each port maximum of 40Gb assuming no other system or switch bottlenecks are present. This adapter performs the same function as #5283 but with a high profile (HP) tail stock and cannot be plugged into a low profile Gen-2 slot. The adapters provide two QSFP+ cages, but does not include any transceivers. QSFP+ transceivers are included and permanently attached at each end of the following QDR IB cables: Copper 1m, 3m, 5m (#3287, #3288, and 3289) and Optical 10m, 30m (#3290, #3293).
- Attributes provided: PCIe2 2-Port 4X IB QDR Adapter 40Gb
- Attributes required: PCIe Gen2 full high slot
- For 8205-E6D: (#5285)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 2)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#5286) - PCIe2 LP 2-port 10GbE SFP+ Copper Adapter
(No Longer Available as of January 6, 2015)
This PCIe Gen2 adapter provides two 10 Gb copper SFP+ ports. Active Copper twinax cables up to 5 meter in length are supported such as provided by feature #EN01, #EN02 or #EN03.. Note that SFP+ twinax copper is NOT AS/400 5250 twinax or CX4 or 10 GBASE-T. Active cables differ from passive cables.
Note the #5286 and #5288 adapters are physically identical except for their tail stock - #5286= low profile and #5288= full high.
- Characteristics
- MSI-X and support of legacy pin interrupts
- 10GBASE-Direct attach SFP+ twinax cable
- IEEE 802.1p priority and 802.1Q VLAN tagging
- IEEE 802.3x flow control
- Link aggregation, 802.3ad 802.3 compliance
- IEEE 802.3ad load-balancing and failover
- Ether II and 802.3 encapsulated frames
- Multiple MAC addresses per interface
- Jumbo frames up to 9.6 KB
- TCP checksum offload for IPv4
- TCP segmentation Offload (TSO) for IPv4
- UDP checksum offload for IPv4
- Receive side scaling and packet steering
- Line rate packet filtering and attack protection
- Attributes provided: PCIe Gen 2.0 x8 10GBASE adapter with two SFP+ ports
- Attributes required: 1 low profile Gen2 PCIe slot, one or two active copper cables with transceiver on end of cable
- For 8205-E6D: (#5286)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported only with VIOS
- IBM i 7.1 supported only with VIOS
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 4 supported in the CEC with #5685 installed.
(#5287) - PCIe2 2-port 10GbE SR Adapter
(No Longer Available as of January 6, 2015)
The PCIe2 2-port 10GbE SR Adapter is a full high, Gen2, high performance adapter that uses a LC Duplex type connector and is capable of transferring data a distance of 300m over MMF-850nm Fiber cable. The product conforms to the IEEE, 802.3ae 10GBASE-SR specification for Ethernet transmission.
Characteristics
- MSI-X and support of legacy pin interrupts
- 10GBASE-Direct attach SFP+ twinax cable
- IEEE 802.3ae (10 GbE)
- IEEE 802.1p priority and 802.1Q VLAN tagging
- IEEE 802.3x flow control
- Link aggregation, 802.3ad 802.3 compliance
- IEEE 802.3ad load-balancing and failover
- Ether II and 802.3 encapsulated frames
- Multiple MAC addresses per interface
- Jumbo frames up to 9.6 KB
- TCP checksum offload for IPv4
- TCP segmentation Offload (TSO) for IPv4
- UDP checksum offload for IPv4
- Receive side scaling and packet steering
- Line rate packet filtering and attack protection
- Attributes provided: PCIe-gen 2.0 x8 10GBASE-SR short-reach optics adapter
- Attributes required: 1 full high Gen2 PCIe slot, Fiber Cable (Optional LC-SC 62.5 micron converter cable, 50 micron LC-SC connections), LC wrap plug-d
- For 8205-E6D: (#5287)
- Minimum required: 0
- Maximum allowed: 5 (Initial order maximum: 5)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- CEC and system maximum is 5.
- #5284 and #5287 adapters are physically identical except for their tail stock - #5284= low profile and #5287= full high
(#5288) - PCIe2 2-port 10GbE SFP+ Copper Adapter
(No Longer Available as of January 6, 2015)
Copper twinax cables up to 5 meter in length are supported such as provided by feature #EN01, #EN02 or #EN03.. Note that SFP+ twinax copper is NOT AS/400 5250 twinax or CX4 or 10 GBASE-T. Active cables differ from passive cables.
Note the #5286 and #5288 adapters are physically identical except for their tail stock - #5286= low profile and #5288= full high.
- Characteristics
- MSI-X and support of legacy pin interrupts
- 10GBASE-Direct attach SFP+ twinax cable
- IEEE 802.1p priority and 802.1Q VLAN tagging
- IEEE 802.3x flow control
- Link aggregation, 802.3ad 802.3 compliance
- IEEE 802.3ad load-balancing and failover
- Ether II and 802.3 encapsulated frames
- Multiple MAC addresses per interface
- Jumbo frames up to 9.6 KB
- TCP checksum offload for IPv4
- TCP segmentation Offload (TSO) for IPv4
- UDP checksum offload for IPv4
- Receive side scaling and packet steering
- Line rate packet filtering and attack protection
- Attributes provided: PCIe Gen 2.0 x8 10GBASE adapter with two SFP+ ports.
- Attributes required: 1 full high Gen2 PCIe slot, one or two active copper cables with transceiver on end of cable
- For 8205-E6D: (#5288)
- Minimum required: 0
- Maximum allowed: 5 (Initial order maximum: 5)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- CEC and system maximum is 5.
(#5289) - 2 Port Async EIA-232 PCIe Adapter
(No Longer Available as of August 14, 2015)
Adapter provides connection for 2 asynchronous EIA-232 devices. Ports are programmable to support EIA-232 protocols, at a line speed of 128K bps. Two RJ45 connections are located on the rear of the adapter. To attach to devices using a 9-pin (DB9) connection, use an RJ45-to-DB9 converter. For convenience, one converter is included with this feature. One converter for each connector needing a DB9 connector is needed.
The converter cable shipped with the feature is a 10-pin RJ-45 approximately 30 cm or 1 foot in length. 10-pin is often used for DCE devices like modems. DTE devices may be able to use fewer pin connections. Multiple RJ-45 pin out options are used and sold across the industry. The #3930 feature provides an 8-pin RJ45-to-DB9 converter cable. If an addition 10-pin RJ45-to-DB9 connector like the cable provided with the adapter is desired, it is commonly available from multiple sources and identified as a serial cable with a Digi part number 76000239. It is also possible to look up the cable's pin out specifications and build your own cables.
Note: #5289 and #5290 are physically and electrically identical adapters except for the type of PCIe slot used (full-high or low profile). Note also the 2-port #5289/5290 is functionally nearly identical to the 4-port #5785/5277 except for the number and type of connectors.
Limitation: As of 2012, IBM i does not support PPP protocol. Also IBM i only supports use on POWER7 and POWER7+ servers.
- Attributes provided: 2-Port Asynchronous EIA-232 via 2x RJ45 connectors, one RJ45-to-DB9 converter cable.
- Attributes required: 1 full high PCIe Slot
- For 8205-E6D: (#5289)
- Minimum required: 0
- Maximum allowed: 12 (Initial order maximum: 12)
- OS level required:
- AIX Version 7.1 with the 7100-02 Technology Level and Service Pack 2, or later
- AIX Version 6.1 with the 6100-08 Technology Level and Service Pack 2, or later
- AIX Version 6.1 with the 6100-07 Technology Level and Service Pack 7, or later (Planned availability March 29, 2013)
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- CEC maximum is 2.
- System maximum of 12 with 2 in the CEC and 10 in 4 x #5802.
(#5290) - PCIe LP 2-Port Async EIA-232 Adapter
(No Longer Available as of August 14, 2015)
Adapter provides connection for 2 asynchronous EIA-232 devices. Ports are programmable to support EIA-232 protocols, at a line speed of 128K bps. Two RJ45 connections are located on the rear of the adapter. To attach to devices using a 9-pin (DB9) connection, use an RJ45-to-DB9 converter. For convenience, one converter is included with this feature. One converter for each connector needing a DB9 connector is needed.
The converter cable shipped with the feature is a 10-pin RJ-45 approximately 30 cm or 1 foot in length. 10-pin is often used for DCE devices like modems. DTE devices may be able to use fewer pin connections. Multiple RJ-45 pin out options are used and sold across the industry. The #3930 feature provides an 8-pin RJ45-to-DB9 converter cable. If an addition 10-pin RJ45-to-DB9 connector like the cable provided with the adapter is desired, it is commonly available from multiple sources and identified as a serial cable with a Digi part number 76000239. It is also possible to look up the cable's pin out specifications and build your own cables.
Note: #5289 and # 5290 are physically and electrically identical adapters except for the type of PCIe slot used (full-high or low profile). Note also the 2-port #5289/5290 is functionally nearly identical to the 4-port #5785/5277 except for the number and type of connectors.
Limitation: As of 2012, IBM i does not support PPP protocol. Also IBM i only supports use on POWER7 and POWER7+ servers.
- Attributes provided: 2-Port Asynchronous EIA-232 via 2x RJ45 connectors, one RJ45-to-DB9 converter cable.
- Attributes required: 1 full high PCIe Slot
- For 8205-E6D: (#5290)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 2)
- OS level required:
- AIX Version 7.1 with the 7100-02 Technology Level and Service Pack 2, or later
- AIX Version 6.1 with the 6100-08 Technology Level and Service Pack 2, or later
- AIX Version 6.1 with the 6100-07 Technology Level and Service Pack 7, or later (Planned availability March 29, 2013)
- Linux supported
- IBM i 7.1. or later
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- CEC and system maximum is 2.
(#5532) - System AC Power Supply, 1925 W
(No Longer Available as of November 30, 2015)
One 1925 watt AC power supply. Two AC power supplies in a CEC enclosure provide redundant power support. If one should fail, it can be exchanged without interrupting the operation of the system. The system requires one functional power supply in each CEC enclosure to remain operational.
Technical note: Also works with DC input (200-250V).
- Attributes provided: AC Power Supply
- Attributes required: None
- For 8205-E6D: (#5532)
- Minimum required: 2
- Maximum allowed: 2 (Initial order maximum: 2)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#5550) - Sys Console On HMC
With #5550, system console function is driven by the Hardware Management Console (HMC) connected to the system. The HMC is required if the following functions are desired/selected for the system:
- Attributes provided: System Console on Hardware Management Console(HMC)
- Attributes required: Hardware Management Console (HMC)
- For 8205-E6D: (#5550)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#5557) - System Console-Ethernet No IOP
(No Longer Available as of November 30, 2015)
Indicates that the system console is driven by an IOP-less Ethernet LAN adapter. This LAN adapter must be dedicated to console support functions and cannot be used for any other purpose.
- Attributes provided: System Console connection through an IOP-less Ethernet LAN adapter
- Attributes required: PCI-X IOP-less Ethernet LAN Adapter
- For 8205-E6D: (#5557)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#5618) - Storage Backplane -- 6 SFF Bays/ SATA DVD/HH Tape
This feature provides a storage backplane which supports six SFF(Small Form Factor) HDDs or SSDs and connections for a slimline SATA DVD and a half high tape for either a tape drive or USB removable disk drive. SFF drives are supported using JBOD, RAID-0, or RAID-10. Split backplane (3x3) and RAID-10 support requires additional feature #5631 if a Power 720/740 with Gen1 slots or requires additional feature #EJ02 if a Power 720/740 with Gen2 slots.. No PCI slot is used for this controller. This feature does not provide RAID-5/6, write cache, or an external SAS port.
- Attributes provided: Storage Backplane
- Attributes required: None
- For 8205-E6D: (#5618)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Either #5618 or #EJ01 is part of the system minimum configuration.
(#5619) - 80/160GB DAT160 SAS Tape Drive
(No Longer Available as of February 14, 2014)
The Internal Tape Drive is a 5.25-inch, half-high for save/restore and archive functions. This DDS Gen6 tape drive uses the new larger IBM DAT160 and 4-mm data cartridges and is compression capable, providing a capacity of up to 160 GB (assuming 2:1 compression ratio) - a significant increase in capacity over the previous 36/72 GB 4-mm internal tape drives (when using DAT160 Data Cartridge)
Characteristics
- Capacity: 80 GB native mode, 160 GB (typical) compression mode
- DDS Gen6
- Form Factor: 5.25-inch half high
- Media: IBM DAT160 and 4mm media
- Technology: Helical scan, rotating head
- Operation: Streaming
- Data Transfer Rate: 6MBps native mode,
- Interface: SAS
- Compatability: DDS4 (R/W), DAT72 (R/W) and DAT160 (R/W)
- Attributes provided: Attributes provided: 4mm tape capability, Test Cartridge, and a Cleaning Cartridge
- Attributes required: One 1.6-inch (41mm) half-high media
- For 8205-E6D: (#5619)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- CEC and system maximum is 1.
- Requires SAS cable group #3656 (SAS SFF).
(#5638) - 1.5TB/3.0TB LTO-5 SAS Tape Drive
This SAS tape drive is located in the HH bay of the supporting system units and run by the integrated SAS controller in those system units. A SAS cable feature code such as #3656 or #3657 is required for the drive's attachment inside the system unit.
The drive uses industry standard Ultrium media. This drive will Write/Read Ultrium5 (LTO-5), Write/Read Ultrium4 (LTO-4) and Read Ultrium3 (LTO-3) formats. With LTO-5 media, it has capacity of 1.5 TB native or 3.0 TB with typical compression. Compression capability is built into the drive hardware. Both write many and write once (WORM) cartridges are supported.
The drive uses linear technology and operates in streaming mode. The data transfer rate is 140 MB/sec with LTO-5 media. Data transfer rates are slower using LTO-4 or LTO-3 media. To enhance overall operational performance and to minimize normal head wear, matching down speed capability is supported down to 40 MB/s.
Limitation: #5638 encryption is not natively supported by AIX or IBM i, but is supported by the drive hardware using user-provided applications in an AIX or Linux environment.
- Attributes provided: One HHLTO-5 SAS Tape Drive, one LTO-5 Cleaning Cartridge, and one LTO-5 Test Cartridge.
- Attributes required: One 1.6-inch (41mm) half-high media bay, One SAS cable
- For 8205-E6D: (#5638)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note: VIOS attachment requires, version 2.2 or later
(#5685) - PCIe Riser Card (Gen2)
(No Longer Available as of March 31, 2018)
This optional feature provides 4 PCIe Gen2 connectors allowing for installation of 4 Low Profile (LP) Gen1 or Gen2 adapter cards. This feature is installed in GX++ slot 1.
- Attributes provided: Four PCIe Low Profile adapter slots
- Attributes required: None
- For 8205-E6D: (#5685)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#5689) - DAT160 Data Cartridge
80GB Native/160GB Compressed
- Attributes provided: Five DAT160 Data Cartridges
- Attributes required: None
- For 8205-E6D: (#5689)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5700) - IBM Gigabit Ethernet-SX PCI-X Adapter
The IBM Gigabit Ethernet-SX PCI-X Adapter provides a 1 Gbps (1000 Base-SX) full-duplex Ethernet LAN connection with throughput on a standard shortwave multimode optical cable which conforms to the IEEE 802.3z standard. The adapter supports distances of 260m for 62.5 micron Multi Mode Fiber (MMF) and 550m for 50.0 micron MMF. AIX Network Install Manager (NIM) boot capability is supported with this adapter.
Note: For optimum performance, the adapter should be placed in a 64 bit PCI-X card slot.
Note: The IBM Gigabit Ethernet-SX PCI-X Adapter (#5700) incorporates an LC type connector on the card. This new, smaller form factor connector is being used by the industry for the next generation of fiber optic networks. If connecting into an older, existing SC type connector network, an LC-SC 62.5 Micron Fiber Converter Cable (#2459) or LC-SC 50 Micron Fiber Converter Cable (#2456) is required.
Limitation: Half Duplex (HDX) mode is not supported.
- Attributes provided: One full-duplex 1000Base-SX fiber connection to a Gigabit Ethernet LAN.
- Attributes required: One available PCI or PCI-X card slot
- For 8205-E6D: (#5700)
- Minimum required: 0
- Maximum allowed: 48 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC.
- System maximum of 48 with 8 x #5796.
(#5701) - IBM 10/100/1000 Base-TX Ethernet PCI-X Adapter
The IBM 10/100/1000 Base-TX Ethernet PCI-X Adapter is a Full Duplex Gigabit Ethernet adapter designed with highly integrated components. This adapter can be configured to run at 10, 100, or 1000 Mbps data rates. The adapter interfaces to the system via the PCI-X bus and connects to the network using a 4-pair CAT-5 Unshielded Twisted Pair (UTP) cable for distances of up to 100m. AIX Network Install Manager (NIM) boot capability is supported with this adapter. The adapter conforms to the IEEE 802.3ab 1000Base-T standard. The adapter also supports jumbo frames when running at the 1000 Mbps speed.
Note: For optimum performance, adapter should be placed in a 64 bit PCI-X card slot.
Limitations: The 1000 Mbps speed is not supported in Half Duplex (HDX) mode.
IOP and IOPless version
- Attributes provided: One full-duplex 10/100/1000Base-TX UTP connection to a Gigabit Ethernet LAN.
- Attributes required: One available PCI or PCI-X card slot
- For 8205-E6D: (#5701)
- Minimum required: 0
- Maximum allowed: 48 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC.
- System maximum of 48 with 8 x #5796.
(#5706) - IBM 2-Port 10/100/1000 Base-TX Ethernet PCI-X Adapter
(No Longer Available as of May 31, 2017)
The IBM 2-Port 10/100/1000 Base-TX Ethernet PCI-X Adapter is a Full Duplex, dual ported, Gigabit Ethernet adapter designed with highly integrated components. This adapter can be configured to run each port at 10, 100, or 1000 Mbps data rates. The adapter interfaces to the system via a PCI or PCI-X bus and connects to a network using a 4-pair CAT-5 Unshielded Twisted Pair (UTP) cable for distances of up to 100m. AIX Network Install Manager (NIM) boot capability is supported with this adapter. The adapter conforms to the IEEE 802.3ab 1000Base-T standard. The adapter also supports jumbo frames when running at the 1000 Mbps speed.
A function called 'Large Send' or sometimes known as TCP Segmentation is also provided by this adapter. This function offloads the TCP segmentation operation from the AIX IP layer to the adapter for outgoing (transmit side) TCP segments. Another function known as "Checksum Offload" which offloads the TCP/UDP Checksum Operation or workload from the CPU to the adapter is also provided.
The IBM 2-Port 10/100/1000 Base-TX Ethernet PCI-X Adapter (#5706) should be considered where maximum port density is required per I/O card slot. For a suggested maximum number of adapters taking performance into consideration, refer to the PCI Adapter Placement Reference SA38-0538. If card slots are not the limiting factor and maximum throughput is required, the single port IBM 10/100/1000 Base-TX Ethernet PCI-X Adapter (#5701) is the preferred solution.
Note: For optimum performance, the adapter should be placed in a 64 bit PCI-X card slot whenever possible.
Limitations: The 1000 Mbps speed is not supported in Half Duplex (HDX) mode.
- Attributes provided: Two full-duplex 10/100/1000Base-TX UTP connections to Gigabit Ethernet LAN(s).
- Attributes required: One available PCI or PCI-X card slot
- For 8205-E6D: (#5706)
- Minimum required: 0
- Maximum allowed: 48 (Initial order maximum: 48)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Not supported in the CEC.
- System maximum of 48 with 8 x #5796.
(#5708) - 10Gb FCoE PCIe Dual Port Adapter
(No Longer Available as of January 22, 2016)
10 Gb FCoE PCIe Dual Port Adapter (#5708) is a high-performance, 10 Gb, dual port, PCIe Converged Network Adapter (CNA) utilizing SR optics. Each port can provide NIC (Network Interface Card) traffic and Fibre Channel functions simultaneously. CCIN is 2B3B See also feature #5270 for the identical adapter except it has a low profile tail stock.
Highlights
- PCIe 2.0 adapter with x8 Gen 1
- Convergence Enhanced Ethernet (CEE) supported
- SR optical transceiver with LC connection provides up to 300m cable length
- Non-volatile error log on the adapter
- Supported with AIX and Linux and VIOS for FC and Ethernet NIC.
- Supported with IBM i under VIOS for FC and Ethernet NIC
- SAN and Network boot support for AIX, Linux
- Requires FCoCEE capable switches for full FC+Ethernet capability. Ethernet only functionality if attached to ordinary Ethernet switch.
- Utilizes existing cabling that supports 10 Gb SR
- Based on Qlogic Converged Network Adapter (CNA)
- NPIV support requires VIOS for all OS environments
Configuration maximum when used for NIC traffic (not Fibre Channel usage)
- Recommended performance Max assuming high utilization, One adapter per four active processors cores.
- Recommended connectivity Max assuming high utilization, two adapters per one physical processor core.
- Attributes provided: 10 Gb FCoE PCIe Dual Port Adapter
- Attributes required: Open PCIe slot
- For 8205-E6D: (#5708)
- Minimum required: 0
- Maximum allowed: 44 (Initial order maximum: 44)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 5 supported in the CEC.
- System maximum of 45 with 5 in the CEC and 4 x #5802/#5877.
(#5713) - 1 Gigabit iSCSI TOE PCI-X on Copper Media Adapter
(No Longer Available as of March 31, 2018)
The 1 Gigabit iSCSI TOE PCI-X adapter encapsulates SCSI Commands and data into TCP and transports them over the Ethernet via IP packets. The adapter operates as an iSCSI TOE (TCP/IP Offload Engine). This offload function eliminates host protocol processing and reduces CPU interrupts. Adapter uses RJ45 Gigabit Ethernet connector.
- Attributes provided: Offload of host protocol processing
- Attributes required: Available PCI-X Slot
- For 8205-E6D: (#5713)
- Minimum required: 0
- Maximum allowed: 48 (Initial order maximum: 48)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Not supported in the CEC.
- System maximum of 48 with 8 x #5796.
(#5714) - 1 Gigabit iSCSI TOE PCI-X on Optical Media Adapter
The 1 Gigabit iSCSI TOE PCI-X adapter encapsulates SCSI Commands and data into TCP and transports them over the Ethernet via IP packets. The adapter operates as an iSCSI TOE (TCP/IP Offload Engine). This offload function eliminates host protocol processing and reduces CPU interrupts. Adapter uses Small form factor LC type fiber optic connector.
- Attributes provided: Offload of host protocol processing
- Attributes required: Available PCI-X Slot
- For 8205-E6D: (#5714)
- Minimum required: 0
- Maximum allowed: 48 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC.
- System maximum of 48 with 8 x #5796.
(#5716) - 2 Gigabit Fibre Channel PCI-X Adapter
The 2 Gigabit Fibre Channel PCI-X Adapter is a 64-bit address/data, short form factor PCI-X adapter with an LC type external fiber connector. With the use of appropriate optical fiber cabling, this adapter provides the capability for a network of high speed local and remote located storage. The 2 Gigabit Fibre Channel PCI-X Adapter will auto-negotiate for the highest data rate (either 1 Gbps or 2 Gbps) of which the device or switch is capable. Distances of up to 500 meters running at 1 Gbps data rate and up to 300 meters running at 2 Gbps data rate are supported between the adapter and an attaching device or switch. When used with IBM supported Fibre Channel storage switches supporting long-wave optics, distances of up to 10 kilometers are capable running at either 1 Gps or 2 Gps data rates.
The 2 Gigabit Fibre Channel PCI-X Adapter can be used to attach devices either directly, or by means of Fibre Channel Switches. If attaching a device or switch with a SC type fiber connector(s), use of an LC-SC 50 Micron Fiber Converter Cable (#2456) or a LC-SC 62.5 Micron Fiber Converter Cable (#2459) is required.
Refer to the following IBM storage subsystem web page for additional supported server attachment information for IBM devices.
Consult with your IBM representative or Business Partner for additional information relative to any third party attachment.
- Attributes provided: 1 Fibre Channel/FC-AL interface
- Attributes required: 1 empty PCI or PCI-X slot
- For 8205-E6D: (#5716)
- Minimum required: 0
- Maximum allowed: 48 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC.
- System maximum of 48 with 8 x #5796.
(#5717) - 4-Port 10/100/1000 Base-TX PCI Express Adapter
(No Longer Available as of January 1, 2014)
The 4-Port 10/100/1000 Base-TX PCI Express Adapter is short/ low- profile, full duplex, four-ported Gigabit Ethernet adapter that can be configured to run any of the ports at 1000,100 or 10 Mbps data rate. This adapter interfaces to the system via a PCIe bus and connects to a network using a 4-pair CAT-5 Unshielded Twisted Pair (UTP) cable for distance of up to 100m. Each port is independent of one another and is boot capable under AIX Network install manager (NIM). The adapter conforms to the IEEE 802.3ab 1000Base-T standard. The #5717 supports jumbo frames when running at the 1000 Mbps speed.
The 4-Port 10/100/1000 Base-TX PCI Express adapter (#5717) should be considered where maximum port density is required per I/O card slot. For a suggested maximum number of adapters considering performance, see the IBM System p PCI placement guide (SA76-0090) for information about the PCIe slots on your system unit.
Limitations: The 1000 Mbps speed is not supported in Half Duplex (HDX) mode.
- Attributes provided: Four-ported Gigabit Ethernet
- Attributes required: One available PCIe card slot
- For 8205-E6D: (#5717)
- Minimum required: 0
- Maximum allowed: 44 (Initial order maximum: 44)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 5 supported in the CEC.
- System maximum of 45 with 5 in the CEC and 5 x #5802/#5877.
(#5721) - 10 Gb Ethernet-SR PCI-X 2.0 DDR Adapter
The adapter supports distances of up to 33m using 62.5 um multimode fiber or 300m using 50 um multimode fiber with 2000 MHz*km minimum model bandwidth at 850 nm wavelength. The fiber cable connects to the adapter with LC type connector. The adapter conforms to the IEEE 802.3ae standard.
- Attributes provided: Provides high-end bandwidth for networking
- Attributes required: PCI-X slot or for improved bandwidth plug into PCI-X 2.0 DDR slot.
- For 8205-E6D: (#5721)
- Minimum required: 0
- Maximum allowed: 48 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC.
- System maximum of 48 with 8 x #5796.
(#5722) - 10 Gb Ethernet-LR PCI-X 2.0 DDR Adapter
The adapter supports a maximum of 10 kilometers of 1310nm 9um single-mode fiber optic cable. The adapter conforms to the IEEE 802.3ae standard. The adapter requires 9um single-mode fiber optic cables and uses a SC connector to facilitate connecting into network infrastructure components like 10 Gigabit Ethernet switch/router with SC connectors.
- Attributes provided: 10 Gigabit Ethernet connections
- Attributes required: PCI-X slot or for improved bandwidth plug in PCI-X 2.0 DDR slot.
- For 8205-E6D: (#5722)
- Minimum required: 0
- Maximum allowed: 48 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC.
- System maximum of 48 with 8 x #5796.
(#5723) - 2-Port Asynchronous EIA-232 PCI Adapter
Connection for 2 Asynchronous EIA-232 devices. Ports are Programmable to support EIA-232 protocols, at a line speed of 128K bps.
- Attributes provided: 2 Asynchronous Ports
- Attributes required: One PCI Slot
- For 8205-E6D: (#5723)
- Minimum required: 0
- Maximum allowed: 48 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC.
- System maximum of 48 with 8 x #5796.
(#5729) - PCIe2 8Gb 4-port Fibre Channel Adapter
(No Longer Available as of March 31, 2018)
PCIe Gen2 8 Gigabit quad port Fibre Channel Adapter is a high- performance 8x short form adapter based on the Emulex LPe12004 PCIe Host Bus Adapter (HBA). Each port provides single initiator capability over a fibre link or with NPIV, multiple initiator capability is provided. The ports have LC type connectors and utilize shortwave laser optics. The adapter operates at link speeds of 2, 4, and 8 Gbps and will automatically negotiate to the highest speed possible. LEDs on each port provide information on the status and link speed of the port.
The adapter connects to a Fibre Channel switch. Direct device attachment has not been tested and is not supported.
N_Port ID Virtualization (NPIV) capability is supported through VIOS.
Cables are the responsibility of the customer. Use multimode fibre optic cables with short-wave lasers that adhere to the following specifications:
OM3 - multimode 50/125 micron fibre, 2000 MHz*km bandwidth
OM2 - multimode 50/125 micron fibre, 500 MHz*km bandwidth
OM1 - multimode 62.5/125 micron fibre, 200 MHz*km bandwidth
Because core sizes are different, OM1 cables can only be connected to other OM1 cables. For best results, OM2 cables should not be connected to OM3 cables. However, if an OM2 cable is connected to an OM3 cable, the characteristics of the OM2 cable apply to the entire length of the cables.
The following table shows the supported distances for the three different cable types at the three different link speeds.
Cable 2.125 Gbps 4.25 Gbps 8.5 Gbps
------ ------------ ----------- ----------
OM3 .5m - 500m .5m - 380m .5m - 150m
OM2 .5m - 300m .5m - 150m .5m - 50m
OM1 .5m - 150m .5m - 70m .5m - 21m
#5729 feature indicates a full high adapter. CCIN is 5729.
A Gen2 PCIe slot is required to provide the bandwidth for all four ports to operate at full speed.
Consult with your IBM representative or Business Partner for additional information relative to any third party attachment.
See also optional wrap plug feature #ECW0 which is:
- a) Required to run some diagnostic procedures and
- b) in some cases may speed system boot when placed in empty ports as well as avoid useless messages pointing to a planned empty port.
- Attributes provided: Four Port Fibre Channel Adapter
- Attributes required: 1 Empty PCIe Gen2 slot
- For 8205-E6D: (#5729)
- Minimum required: 0
- Maximum allowed: 5 (Initial order maximum: 5)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- IBM i - not supported use VIOS
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 5 supported in the CEC.
- Supported by VIOS, 2.2.1.0 or later
- IBM i requires VIOS, 2.2.1.0 or later
(#5732) - 10 Gigabit Ethernet-CX4 PCI Express Adapter
(No Longer Available as of July 19, 2013)
The 10 Gigabit Ethernet-CX4 PCI Express Adapter is a low profile high performance adapter that transfers data over 4-lanes in each direction over copper cabling supporting a distance up to 15m.The product conforms to the IEEE, 802.3ak 10GBASE-CX4 specification for Ethernet transmission.
Highlights:
- Implements iWARP RDMA/RDDP (Remote Direct Data Placement) which adheres to IETF (Internet Engineering Task Force) standards. (Linux Only)
- RDMA-enabled NIC (RNIC) specifically optimized for cluster computing (Linux Only)
Full iSCSI software and hardware initiator support. (Linux Only)
- Hardware PDU Offload (Linux Only)
- iSCSI Header & Data Digest (CRC) generation & checking ( Linux Only)
Attributes provided:
- PCIe-V1.1 x8
- MSI-X, MSI and support of legacy pin interrupts
- 10GBASE-CX short-reach copper
- IEEE 802.3ae (10 GbE)
- IEEE 802.1p priority and 802.1Q VLAN tagging
- IEEE 802.3x flow control
- Link aggregation, 802.3ad 802.3 compliance
- IEEE 802.3ad load-balancing and failover
- Ether II and 802.3 encapsulated frames
- Multiple MAC addresses per interface
- Jumbo frames up to 9.6 Kbytes
- TCP checksum offload for IPv4 and IPv6
- TCP segmentation Offload (TSO) for IPv4 and IPv6
- UDP checksum offload for IPv4 and IPv6
- Receive side scaling and packet steering
- Line rate packet filtering and attack protection
- IETF RDDP and RDMAC iWARP compliance (Linux Only)
- APIs: RNIC-PI, kDAPL and Open Fabrics Enterprise Distribution(OFED) 1.4 (Linux Only)
- Attributes provided: PCIe-V1.1 x8 Ethernet
- Attributes required: PCIe Express Slot, Copper CX4 Cables, 4x wrap plug
- For 8205-E6D: (#5732)
- Minimum required: 0
- Maximum allowed: 44 (Initial order maximum: 44)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 5 supported in the CEC.
- System maximum of 45 with 5 in the CEC and 5 x #5802/#5877.
(#5735) - 8 Gigabit PCI Express Dual Port Fibre Channel Adapter
(No Longer Available as of March 31, 2018)
The 8 Gigabit PCI Express Dual Port Fibre Channel Adapter is a high-performance 8x short form adapter based on the Emulex LPe12002 PCIe Host Bus Adapter (HBA). Each port provides single initiator capability over a fibre link. The ports have LC type connectors and utilize shortwave laser optics. The adapter operates at link speeds of 2, 4, and 8 Gbps and will automatically negotiates to the highest speed possible. LEDs on each port provide information on the status and link speed of the port.
The adapter connects to a Fibre Channel switch (AIX, IBM i, Linux,VIOS). If in an IBM i environment, devices can also be directly attached.
N_Port ID Virtualization (NPIV) capability is supported through VIOS.
Cables are the responsibility of the customer. Use multimode fibre optic cables with short-wave lasers that adhere to the following specifications:
OM3 - multimode 50/125 micron fibre, 2000 MHz*km bandwidth
OM2 - multimode 50/125 micron fibre, 500 MHz*km bandwidth
OM1 - multimode 62.5/125 micron fibre, 200 MHz*km bandwidth
Because core sizes are different, OM1 cables can only be connected to other OM1 cables. For best results, OM2 cables should not be connected to OM3 cables. However, if an OM2 cable is connected to an OM3 cable, the characteristics of the OM2 cable apply to the entire length of the cables.
The following table shows the supported distances for the three different cable types at the three different link speeds.
Cable 2.125 Gbps 4.25 Gbps 8.5 Gbps
------ ------------ ----------- -----------
OM3 .5m - 500m .5m - 380m .5m - 150m
OM2 .5m - 300m .5m - 150m .5m - 50m
OM1 .5m - 150m .5m - 70m .5m - 21m
#5735 feature indicates a full high adapter. #5273 feature indicates a low profile adapter which is electronically identical. CCIN is 577D. Consult with your IBM representative or Business Partner for additional information relative to any third party attachment.
See also optional wrap plug feature #ECW0 which is:
- a) Required to run some diagnostic procedures and
- b) in some cases may speed system boot when placed in empty ports as well as avoid useless messages pointing to a planned empty port.
- Attributes provided: Dual Port Fibre Channel
- Attributes required: 1 Empty PCIe slot
- For 8205-E6D: (#5735)
- Minimum required: 0
- Maximum allowed: 44 (Initial order maximum: 44)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 5 supported in the CEC.
- System maximum of 45 with 5 in the CEC and 5 x #5802/#5877.
(#5736) - PCI-X DDR Dual Channel Ultra320 SCSI Adapter
(No Longer Available as of July 11, 2014)
The PCI-X DDR Dual Channel Ultra320 SCSI Adapter (#5736) is a 64-bit 3.3-volt adapter and is an excellent solution for high- performance SCSI applications. The PCI-X Dual Channel Ultra320 SCSI Adapter provides two SCSI channels (busses), each capable of running 320 MBps (max.). Each SCSI bus can only support external attach SCSI devices.
In order to achieve an Ultra320 SCSI bus data rate of up to 320 MB per second and maintain a reasonable drive distance, the adapter utilizes Low Voltage Differential (LVD) drivers and receivers. To utilize the 320 MB per second performance, all attaching devices should also be Ultra320 LVD devices; however, if Ultra2, Ultra3, or Ultra320 devices coexist on the same bus, each device will operate at its rated speed. For lower speed single-ended (SE) devices, the SCSI bus will switch to single-ended (SE) performance and interface to all devices on that SCSI bus at the lower SE bus data rate of the device.
Two VHDCI 68-pin connectors are mounted on the adapter's end bracket allowing attachment of various LVD and SE external subsystems. A 0.3-meter converter cable, VHDCI to P, Mini-68 pin to 68-pin, (#2118) can be used with older external SE devices or subsystems to allow connection to the VHDCI connector on the PCI-X DDR Dual Channel Ultra320 SCSI Adapter.
Two external ports provide connectivity to numerous other SCSI external subsystems. Check the external subsystem sales/web pages for verification of connectivity support with this adapter.
The PCI-X Dual Channel Ultra320 SCSI Adapter (#5736) is a native boot adapter. The adapter also supports target mode.
Feature #5736 and #5806 are physically identical cards with the same 571A CCIN. Different features are used to help IBM configurator tool understand whether or not an IOP is being used with the adapter. #5806 indicates an IOP is present.
Limitations:
- The two external ports do not support the connection to the IBM 7131-105 IBM Multi-Storage Tower Model 105.
- The Dual Channel Ultra320 SCSI nonRAID Adapter has ports that are capable at running at ultra320 SCSI speeds (up to 320 MBytes/s).
- Attributes provided: Attachment of external SCSI devices only on Power7 Servers.
- Attributes required: One available 3.3 volt PCI or PCI-X slot or PCI-X 2.0 DDR slot
- For 8205-E6D: (#5736)
- Minimum required: 0
- Maximum allowed: 48 (Initial order maximum: 48)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Not supported in the CEC.
- System maximum of 48 with 8 x #5796.
(#5740) - 4-Port 10/100/1000 Base-TX PCI-X Adapter
The 4-Port 10/100/1000 Base -TX PCI-X adapter is a full height PCI-X 1.0a Ethernet adapter which supports four Gigabit ports on a single adapter, delivers increased bandwidth for slot-constrained servers, and is designed to provide high connectivity and reliability using two integrated, dual-port Gigabit Ethernet controllers.
- Four RJ-45 ports
- 3.3 volts, 64-bit 133 MHz with 64-bit Bus Mastering on the PCI-X bus
- IEEE 802.3ab 1000Base-T compliant
- IEEE 802.3u 100Base-T compliant
- IEEE 802.3 10Base-T compliant
- 802.1q VLAN tagging
- Interrupt Moderation
- TCP Segmentation offload and encapsulation in hardware
- Checksum offloading of IP, TCP, and UDP frame
- Increased connectivity while significantly reducing CPU utilization
- Two LED adapter status indicators per port for link activity and speed
- NIM is supported on all 4 ports
- RoHS compliant
Limit Full bandwidth performance may not be achieved with more than one adapter per PCI Host Bridge (PHB) or more than one CPU.
- Attributes provided: Four 10/100/1000 RJ-45 ports
- Attributes required: One available PCI-X card slot
- For 8205-E6D: (#5740)
- Minimum required: 0
- Maximum allowed: 48 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC.
- System maximum of 48 with 8 x #5796.
(#5744) - PCIe2 4-Port 10GbE&1GbE SR&RJ45 Adapter
(No Longer Available as of February 23, 2017)
This PCIe Gen2 Ethernet adapter provides two 10 Gb SFP+ SR optical transceiver ports and two 1 Gb RJ45 ports. This is a full high adapter.
For the 10Gb ports, LC Duplex type connectors and MMF-850nm fiber cable are used. With 62.5 micron OM1, up to 33 meter length fiber cables are supported. With 50 micron OM2, up to 82 meter fiber cable lengths are supported. With 50 micron OM3, up to 300 meter fiber cable lengths are supported.
For the 1Gb RJ45 ports, The RJ45 port, 4-pair CAT-5 Unshielded Twisted Pair (UTP) cable or higher is supported for distances of up to 100 meters is supported. In addition to 1Gb (1000 Mb) networks, 100 Mb networks are also supported, but 10Mb networks are not supported. Note #5744 and #5280 adapters are physically and electronically identical except for their low profile or full high PCI slot attribute.
Highlights
- Implements iWARP RDMA/RDDP (Remote Direct Data Placement) which adheres to IETF (Internet Engineering Task Force) standards. (Linux and 10 Gb port Only)
- RDMA-enabled NIC (RNIC) specifically optimized for cluster computing (Linux and 10 Gb port Only)
- Full iSCSI initiator and target mode stack (Linux and 10 Gb port Only)
- iSCSI Header & Data Digest (CRC) generation & checking (Linux and 10 Gb port Only)
- PDU recovery (Linux and 10 Gb port Only)
Attributes
- MSI-X, MSI and support of legacy pin interrupts
- 10GBASE-SR short-reach optics
- IEEE 802.3ae (10 GbE)
- IEEE 802.3ab (1 GbE)
- IEEE 802.1p priority and 802.1Q VLAN tagging
- IEEE 802.3x flow control
- Link aggregation, 802.3ad 802.3 compliance
- IEEE 802.3ad load-balancing and failover
- Ether II and 802.3 encapsulated frames
- Multiple MAC addresses per interface
- Jumbo frames up to 9.6 Kbytes
- TCP checksum offload for IPv4 and IPv6
- TCP segmentation Offload (TSO) for IPv4 and IPv6
- UDP checksum offload for IPv4 and IPv6
- IETF RDDP and RDMAC iWARP compliance (Linux and 10 Gb port Only)
- APIs: RNIC-PI, kDAPL and OpenFabrics 1.4 (Linux and 10 Gb port Only)
- Attributes provided: PCIe-V1.1 x8 10GBASE-SR short -reach optics adapter
- Attributes required: PCI Express full high slot, Fiber Cable (Optional LC-SC 62.5 micron converter cable, 50 micron LC-SC connections), LC wrap plug-d
- For 8205-E6D: (#5744)
- Minimum required: 0
- Maximum allowed: 5 (Initial order maximum: 5)
- OS level required:
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 5 supported in the CEC.
(#5745) - PCIe2 4-Port 10GbE&1GbE SFP+Copper&RJ45 Adapter
This PCIe Gen2 adapter provides two 10 Gb copper SFP+ ports and two 1 Gb UTP. Copper twinax cables up to 5 meter in length are supported. Note that SFP+ twinax copper is NOT AS/400 5250 twinax or CX4 or 10 GBASE-T. The two 1Gb ports provide attachment to IEEE standard 802.3ab high-speed (1Gbps) Ethernet LANs. They can also be used to connect to existing 10 and 100Mbps Ethernet networks. The port supports UTP CAT 5 or higher media interface.
Highlights
- Implements iWARP RDMA/RDDP (Remote Direct Data Placement) which adheres to IETF (Internet Engineering Task Force) standards. (Linux and 10 Gb port Only)
- RDMA-enabled NIC (RNIC) specifically optimized for cluster computing (Linux and 10 Gb port Only)
- Full iSCSI initiator and target mode stack (Linux and 10 Gb port Only)
- iSCSI Header & Data Digest (CRC) generation & checking (Linux and 10 Gb port Only)
- PDU recovery (Linux and 10 Gb port Only)
Attributes
- MSI-X, MSI and support of legacy pin interrupts
- 10GBASE-SR short-reach optics
- EEE 802.3ae (10 GbE)
- IEEE 802.3ab (1 GbE)
- IEEE 802.1p priority and 802.1Q VLAN tagging
- IEEE 802.3x flow control
- Link aggregation, 802.3ad 802.3 compliance
- IEEE 802.3ad load-balancing and failover
- Ether II and 802.3 encapsulated frames
- Multiple MAC addresses per interface
- Jumbo frames up to 9.6 Kbytes
- TCP checksum offload for IPv4 and IPv6
- TCP segmentation Offload (TSO) for IPv4 and IPv6
- UDP checksum offload for IPv4 and IPv6
- IETF RDDP and RDMAC iWARP compliance (Linux and 10 Gb port Only)
- APIs: RNIC-PI, kDAPL and OpenFabrics 1.4 (Linux and 10 Gb port Only)
- Attributes provided: Two 1 Gb and Two 10Gb Ethernet ports
- Attributes required: One available PCIe Gen 2 slot and under Linux environment.
- For 8205-E6D: (#5745)
- Minimum required: 0
- Maximum allowed: 5 (Initial order maximum: 5)
- OS level required:
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 5 supported in the CEC.
(#5746) - Half High 800GB/1.6TB LTO4 SAS Tape Drive
The SAS Tape Drive uses industry standard Ultrium media. The Tape drive Write/Read Ultrium4 (LTO-4), Write/Read Ultrium3 (LTO-3), and Read Ultrium2 (LT02) formats. It has capacity of 800GB native or 1.6TB Compressed.
Highlights
- Capacity: 800 GB native mode, 1.6 TB (typical) compression mode
- Form Factor: 5.25-inch half high
- Media: IBM Ultrium 4
- Technology: Linear
- Operation: Streaming
- Data Transfer Rate: 120 MB/sec.
- Speed matching down to 31 MB/sec with LTO-4 media
- Interface: SAS
- Compatability: LTO4 (R/W), LTO3 (R/W) and LTO2 (R)
- Attributes provided: Feature includes one each of the following, HHLTO-4 SAS Tape Drive, LTO-4 Cleaning Cartridge, and LTO-4 Test Cartridge.
- Attributes required: One 1.6-inch (41mm) half-high media bay is required and #3657 cable.
- For 8205-E6D: (#5746)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Maximum of 1 allowed in CEC.
- System maximum of 1
(#5747) - IBM LTO Ultrium 4 800 GB Data Cartridge
The Data Cartridge provides storage physical capacity (1.6 TB with 2:1 compression) . Each data cartridge is embedded with an LTO Cartridge Memory (LTO-CM) chip, which is designed to enable fast simultaneous transfer of cartridge-dependent data with IBM tape drives during media load and unload cycles. The green cartridge color distinguishes it from previous generations of IBM LTO Ultrium Media.
- Attributes provided: Five Data Cartridges
- Attributes required: None
- For 8205-E6D: (#5747)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#5748) - POWER GXT145 PCI Express Graphics Accelerator
(No Longer Available as of March 31, 2018)
The POWER GXT145 is a versatile, low-priced 2D graphics accelerator. It can be configured to operate in either 8-bit or 24-bit color modes. This adapter supports both analog and digital monitors. The adapter requires a PCI Express slot. If attaching a device that requires a 15 pin D-Shell receptacle for a VGA connection (eg. when the graphic adapter output is routed directly to a 7316-TF3 display or indirectly through a KVM switch), order a VGA to DVI Connection Converter, feature number 4276 to accommodate the attaching device.
- Hardware Description
- 128-bit graphics processor
- 8-bit indexed, 8-bit true color, or 24-bit true color
- 32 MB SDRAM
- x1 PCI Express interface
- 2 DVI-I (analog/digital video) connectors
- Features Supported
- Up to approximately 16.7 million colors
- Rectangular clipping
- 1 monitor connected analog at up to 2048 x 1536 resolution
- 1 monitor connected digital at up to 1280 x 1024 resolution
- 2nd monitor supported on secondary connecter at up to 1600 x 1200 analog or 1280 x 1024 digital
- 2nd monitor support in AIX is only in clone mode with an analog connection
- APIs Supported
- X-Windows and Motif
- Software Requirements
- The total number of Graphics Adapters in any one partition may not exceed four.
- Attributes provided: 2D Graphics Adapter
- Attributes required: 1 PCI Express Slot
- For 8205-E6D: (#5748)
- Minimum required: 0
- Maximum allowed: 8 (Initial order maximum: 8)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 5 supported in the CEC.
- System maximum of 8.
(#5749) - 4Gbps Fibre Channel (2-Port)
(No Longer Available as of March 31, 2018)
The 4 Gigabit Dual-Port Fibre Channel PCI-X 2.0 DDR Adapter is a 64-bit address/data, short form factor PCI-X adapter with an LC type external fiber connector that provides single or dual initiator capability over an optical fiber link or loop. With the use of appropriate optical fiber cabling, this adapter provides the capability for a network of high-speed local and remote located storage. The adapter will auto-negotiate for the highest data rate between adapter and an attaching device at 1 Gbps, 2 Gbps, or 4 Gbps of which the device or switch is capable. Distances of up to 500 meters running at 1 Gbps data rate, up to 300 meters running at 2 Gbps data rate, and 4 Gbps data rate up to 150 meters are supported between the adapter and an attaching device or switch. When used with IBM Fibre Channel storage switches supporting long-wave optics, distances up to 10 kilometers are capable running at either 1 Gbps, 2 Gbps, or 4 Gbps data rates.
The adapter can be used to attach devices either directly, or by means of Fibre Channel Switches. If attaching a device or switch with a SC type fiber connector(s), use of an LC-SC 50 Micron Fiber Converter Cable (#2456) or a LC-SC 62.5 Micron Fiber Converter Cable (#2459) is required.
Refer to the following IBM storage subsystem web page for additional supported server attachment information for IBM devices.
Consult with your IBM representative or Business Partner for additional information relative to any third party attachment.
- Attributes provided: 2 Fibre Channel Ports
- Attributes required: 1 empty PCI or PCI-X 2.0 slot
- For 8205-E6D: (#5749)
- Minimum required: 0
- Maximum allowed: 48 (Initial order maximum: 48)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Not supported in the CEC.
- System maximum of 48 with 8 x #5796.
(#5758) - 4 GB Single-Port Fibre Channel PCI-X 2.0 DDR Adapter
The 4 Gigabit Single-Port Fibre Channel PCI-X 2.0 DDR Adapter is a 64-bit address/data, short form factor PCI-X adapter with an LC type external fiber connector. With the use of appropriate optical fiber cabling, this adapter provides the capability for a network of high- speed local and remote located storage. The 4 Gigabit Single-Port Fibre Channel PCI-X Adapter will auto-negotiate for the highest data rate between adapter and an attaching device at 1 Gbps, 2 Gbps or 4 Gbps of which the device or switch is capable. Distances of up to 500 meters running at 1 Gbps data rate, up to 300 meters running at 2 Gbps data rate, and 4 Gbps data rate up to 150 meters are supported between the adapter and an attaching device or switch. When used with IBM Fibre Channel storage switches supporting long-wave optics, distances of up to 10 kilometers are capable running at either 1 Gbps, 2 Gbps, or 4 Gbps data rates.
The 4 Gigabit Single-Port Fibre Channel PCI-X Adapter can be used to attach devices either directly, or by means of Fibre Channel Switches. If attaching a device or switch with a SC type fiber connector(s), use of an LC-SC 50 Micron Fiber Converter Cable (#2456) or a LC-SC 62.5 Micron Fiber Converter Cable (#2459) is required.
There are two maximum quantities for High Bandwidth adapters, one for performance, and one for connectivity. Adapter performance may be limited by bandwidth constraints in a network. To maximize High Bandwidth adapter performance in the server the performance maximum quantity should not be exceeded. In applications where the end-to-end network cannot sustain high performance and or connectivity is more important than overall bandwidth performance the performance maximum quantity can be exceeded up to the connectivity maximum quantity.
Refer to the following IBM storage subsystem web page for additional supported server attachment information for IBM devices.
Consult with your IBM representative or Business Partner for additional information relative to any third party attachment.
- Attributes provided: 1 Fibre Channel
- Attributes required: 1 empty PCI or PCI-X 1.0 / 2.0 slot
- For 8205-E6D: (#5758)
- Minimum required: 0
- Maximum allowed: 48 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC.
- System maximum of 48 with 8 x #5796.
(#5759) - 4 Gb Dual-Port Fibre Channel PCI-X 2.0 DDR Adapter
(No Longer Available as of July 11, 2014)
The 4 Gigabit Dual-Port Fibre Channel PCI-X 2.0 DDR Adapter is a 64-bit address/data, short form factor PCI-X adapter with an LC type external fiber connector. With the use of appropriate optical fiber cabling, this adapter provides the capability for a network of high- speed local and remote located storage. The adapter will auto- negotiate for the highest data rate between adapter and an attaching device at 1 Gbps, 2 Gbps, or 4 Gbps of which the device or switch is capable. Distances of up to 500 meters running at 1 Gbps data rate, up to 300 meters running at 2 Gbps data rate, and 4 Gbps data rate up to 150 meters are supported between the adapter and an attaching device or switch. When used with IBM Fibre Channel storage switches supporting long-wave optics, distances up to 10 kilometers are capable running at either 1 Gbps, 2 Gbps, or 4 Gbps data rates.
The adapter can be used to attach devices either directly, or by means of Fibre Channel Switches. If attaching a device or switch with a SC type fiber connector(s), use of an LC-SC 50 Micron Fiber Converter Cable (#2456) or a LC-SC 62.5 Micron Fiber Converter Cable (#2459) is required.
There are two maximum quantities for High Bandwidth adapters, one for performance, and one for connectivity. Adapter performance may be limited by bandwidth constraints in a network. To maximize High Bandwidth adapter performance in the server the performance maximum quantity should not be exceeded. In applications where the end-to-end network cannot sustain high performance and or connectivity is more important than overall bandwidth performance the performance maximum quantity can be exceeded up to the connectivity maximum quantity.
Refer to the following IBM storage subsystem web page for additional supported server attachment information for IBM devices.
Consult with your IBM representative or Business Partner for additional information relative to any third party attachment.
- Attributes provided: 2 Fibre Channel
- Attributes required: 1 empty PCI or PCI-X 2.0 slot
- For 8205-E6D: (#5759)
- Minimum required: 0
- Maximum allowed: 48 (Initial order maximum: 48)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Not supported in the CEC.
- System maximum of 48 with 8 x #5796.
(#5762) - SATA Slimline DVD-RAM Drive
The IBM SATA Slimline DVD-RAM Drive is an internal tray loading, multifunction storage device capable of reading and writing 4.7GB DVD-RAM discs as well as reading a multitude of other optical media discs. This drive also reads Type II (removable from cartridge) DVD-RAM discs. It is a 12.7mm high Slimline form factor, multi- session capable, DVD-RAM drive which provides state of the art performance. System boot and install functions are supported with CD-ROM, DVD and DVD-RAM media.
Characteristics
- Low Profile 12.7mm
- SATA Interface
- Industry standard Slimline SATA connectors
- Supports 8cm and 12cm disk
- Tray Loading
- CD/DVD-ROM/RAM Read 24X/8X/5X
- DVD-RAM Write 5X
- Buffer Size 2MB
- 1 Laser Diode 2 wave length for CD/DVD
- Power +5V/1.8A
Limitations
- DVD video is not supported.
- Drive only reads CD-type formatted media with AIX 5.1 or later.
- Attributes provided: One 4.7GB SATA Slimline DVD-RAM Drive
- Attributes required: One SATA 12.7mm high media bay
- For 8205-E6D: (#5762)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Maximum of 1 allowed in CEC.
- System maximum of 1
(#5767) - 2-Port 10/100/1000 Base-TX Ethernet PCI Express Adapter
(No Longer Available as of May 31, 2017)
The IBM 2-Port 10/100/1000 Base-TX Ethernet PCI Express (PCIe) Adapter is a Full Duplex, dual ported, Gigabit Ethernet adapter designed with highly integrated components. This adapter can be configured to run each port at 10, 100, or 1000 Mbps data rates. The adapter interfaces to the system via a PCIe bus. It is PCIe x4 capable and conforms to the PCIe 1.0a standard. The adapter connects to a network using a 4-pair CAT-5 Unshielded Twisted Pair (UTP) cable for distances of up to 100m. AIX Network Install Manager (NIM) boot capability is supported with this adapter. The adapter conforms to the IEEE 802.3ab 1000Base-T standard. The adapter also supports jumbo frames when running at the 1000 Mbps speed.
A function called 'Large Send' or sometimes known as TCP Segmentation is also provided by this adapter. This function offloads the TCP segmentation operation from the AIX IP layer to the adapter for outgoing (transmit side) TCP segments. Another function known as "Checksum Offload" which offloads the TCP Checksum Operation or workload from the CPU to the adapter is also provided.
The IBM 2-Port 10/100/1000 Base-TX Ethernet PCIe Adapter (#5767) should be considered where maximum port density is required per I/O card slot. For a suggested maximum number of adapters taking performance into consideration, see the IBM System p PCI placement guide (SA76-0090) for information about the PCIe slots on your system unit.
Limitations: The 1000 Mbps speed is not supported in Half Duplex (HDX) mode.
- Attributes provided: Two full-duplex 10/100/1000Base-TX UTP connections to Gigabit Ethernet LAN(s).
- Attributes required: One available PCIe card slot
- For 8205-E6D: (#5767)
- Minimum required: 0
- Maximum allowed: 44 (Initial order maximum: 44)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 5 supported in the CEC.
- System maximum of 45 with 5 in the CEC and 4 x #5802/#5877.
(#5768) - 2-Port Gigabit Ethernet-SX PCI Express Adapter
(No Longer Available as of December 29, 2017)
The IBM 2-Port Gigabit Ethernet-SX PCI Express (PCIe) Adapter provides two 1 Gbps (1000 Base-SX) full-duplex Ethernet LAN connections. The adapter interfaces to the system via a PCIe bus. It is PCIe x4 capable and conforms to the PCIe 1.0a standard. The adapter connects to a network using a 50/62.5 micron shortwave (850 nm) multimode optical cable that conforms to the IEEE 802.3z standard. The adapter supports distances of 260m for 62.5 micron Multi Mode Fiber (MMF) and 550m for 50.0 micron MMF. AIX Network Install Manager (NIM) boot capability is supported with this adapter.
A function called 'Large Send' or sometimes known as TCP Segmentation is also provided by this adapter. This function offloads the TCP segmentation operation from the AIX IP layer to the adapter for outgoing (transmit side) TCP segments. Another function known as "Checksum Offload" which offloads the TCP Checksum Operation or workload from the CPU to the adapter is also provided.
The IBM 2-Port Gigabit Ethernet-SX PCIe Adapter (#5768) should be considered where maximum port density is required per I/O card slot. For a suggested maximum number of adapters taking performance into consideration, see the IBM System p PCI placement guide (SA76-0090) for information about the PCIe slots on your system unit.
Note: The 2-Port IBM Gigabit Ethernet-SX PCIe Adapter incorporates an LC type connector on the card. This new, smaller form factor connector is being used by the industry for the next generation of fiber optic networks. If connecting into an older, existing SC type connector network, an LC-SC 62.5 Micron Fiber Converter Cable (#2459) or LC-SC 50 Micron Fiber Converter Cable (#2456) is required.
Limitation: Half Duplex (HDX) mode is not supported.
- Attributes provided: Two full-duplex 1000Base-SX fiber connections to a Gigabit Ethernet LAN(s).
- Attributes required: One available PCIe card slot
- For 8205-E6D: (#5768)
- Minimum required: 0
- Maximum allowed: 44 (Initial order maximum: 44)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 5 supported in the CEC.
- System maximum of 45 with 5 in the CEC and 4 x #5802/#5877.
(#5769) - 10 Gigabit Ethernet-SR PCI Express Adapter
(No Longer Available as of July 14, 2017)
The 10 Gigabit Ethernet-SR PCI Express Adapter is a full-high, high performance adapter that uses a LC Duplex type connector and is capable of transferring data a distance of 300m over MMF-850nm Fiber cable. The product conforms to the IEEE, 802.3ae 10GBASE-SR specification for Ethernet transmission.
Highlights
- Implements iWARP RDMA/RDDP (Remote Direct Data Placement) which adheres to IETF (Internet Engineering Task Force) standards. (Linux Only)
- RDMA-enabled NIC (RNIC) specifically optimized for cluster computing (Linux Only)
- Full iSCSI initiator and target mode stack (Linux Only)
- iSCSI Header & Data Digest (CRC) generation & checking (Linux Only)
- PDU recovery (Linux Only)
Attributes
- MSI-X, MSI and support of legacy pin interrupts
- 10GBASE-SR short-reach optics
- IEEE 802.3ae (10 GbE)
- IEEE 802.1p priority and 802.1Q VLAN tagging
- IEEE 802.3x flow control
- Link aggregation, 802.3ad 802.3 compliance
- IEEE 802.3ad load-balancing and failover
- Ether II and 802.3 encapsulated frames
- Multiple MAC addresses per interface
- Jumbo frames up to 9.6 Kbytes
- TCP checksum offload for IPv4 and IPv6
- TCP segmentation Offload (TSO) for IPv4 and IPv6
- UDP checksum offload for IPv4 and IPv6
- Receive side scaling and packet steering
- Line rate packet filtering and attack protection
- IETF RDDP and RDMAC iWARP compliance (Linux Only)
- APIs: RNIC-PI, kDAPL and OpenFabrics 1.4 (Linux Only)
- Attributes provided: PCIe-V1.1 x8 10GBASE-SR short -reach optics adapter
- Attributes required: PCI Express slot, Fiber Cable (Optional LC-SC 62.5 micron converter cable, 50 micron LC-SC connections), LC wrap plug-d
- For 8205-E6D: (#5769)
- Minimum required: 0
- Maximum allowed: 44 (Initial order maximum: 44)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 5 supported in the CEC.
- System maximum of 45 with 5 in the CEC and 4 x #5802/#5877.
(#5771) - SATA Slimline DVD-RAM Drive
This DVD drive reads and writes 4.7GB DVD-RAM discs. It also reads Type II (removable from cartridge) DVD-RAM discs. System boot and install functions are supported with CD-ROM, DVD and DVD-RAM media.
Characteristics
- Supports 8cm and 12cm disk
- CD/DVD-ROM/RAM Read 24X/8X/5X
- DVD-RAM Write 5X
- Buffer Size 2MB and can not be disabled
Limitations: DVD video is not supported.
- Attributes provided: One 4.7GB SATA Slimline DVD-RAM Drive
- Attributes required: One SATA/SAS slimline (12.7mm) high media bay
- For 8205-E6D: (#5771)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#5772) - 10 Gigabit Ethernet-LR PCI Express Adapter
(No Longer Available as of April 23, 2017)
The 10GbE Fiber Optic Server Adapter, is 10 Gigabit Ethernet (GbE) Fiber NIC for PCI Express (PCIe) capable systems. The adapter is a high-performance, highly integrated 10 Gigabit Ethernet LAN adapters with PCIe host interface and fiber LAN connectors on the optical modules.
Feature 5772 conforms to the 802.3ae 10GBASE-LR specification for Ethernet transmissions over 1310nm single-mode fiber optic cable for distances up to 10 kilometers.
Highlights
- 10GBASE-LR fiber optic LAN connections
- Eight (8) lane PCIe Host Connector
- PCIe Low-Profile add-in card dimensions (68.9mm x 167.65mm)
- Uses Intel 82598EB MAC
- PCI Express bus interface v1.1 and v.2.0 (Gen 1 only)
- PCIe Hot Plug/Active PCI
- Controller EEPROM and FLASH ROM
- Status LED (Link/Activity)
- Low power PCIe Gen 1 MAC
- *Support either MSI or MSI-X depending on system/OS support for multi-CPU and multi-core systems.
- Dynamic interrupt moderation for lower latency
- Supports 10Gb, full duplex
- Supports EtherChannel with the existing software
- Supports IEEE 802.3ad (link aggregation control protocol)
- IEEE 802.1Q VLANs
- IEEE 802.3x
- IEEE 802.1p
- Transmission Control Protocol (TCP)/User Datagram Protocol (UDP) Checksum Offloading
- Internet Protocol ver 4 (IPv4) Checksum Offloading
- Transmit Checksum Offloading with TCP Segmentation Offload (TSO)/ Large Send Offload
* Supported by SUSE Linux Enterprise Server 10 SP3 for POWER Systems, or later and Red Hat Enterprise Linux for POWER, version 5.4, or later.
- Attributes provided: One 10 Gigabit Ethernet port
- Attributes required: One x8 lane or x16 PCI Express slot
- For 8205-E6D: (#5772)
- Minimum required: 0
- Maximum allowed: 44 (Initial order maximum: 44)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 5 supported in the CEC.
- System maximum of 45 with 5 in the CEC and 4 x #5802/#5877.
(#5773) - 4 Gigabit PCI Express Single Port Fibre Channel Adapter
The 4 Gigabit Single Port Fibre Channel Adapter is a 64-bit address/data, short form factor PCIe adapter with an LC type external fiber connector. With the use of appropriate optical fiber cabling, this adapter provides the capability for a network of high-speed local and remote located storage. The adapter will auto-negotiate for the highest data rate between adapter and an attaching device at 1 Gbps, 2 Gbps or 4 Gbps of which the device or switch is capable. Distances up to 500 meters running at 1 Gbps data rate, up to 300 meters running at 2 Gbps data rate, and 4 Gbps data rate up to 150 meters are supported between the adapter and an attaching device or switch. When used with IBM Fibre Channel storage switches supporting long-wave optics, distances up to 10 kilometers are capable running at either 1 Gbps, 2 Gbps, or 4 Gbps data rates.
The 4 Gigabit PCIe Single Port Fibre Channel Adapter can be used to attach devices either directly, or by means of Fibre Channel Switches. If attaching a device or switch with a SC type fiber connector(s), use of an LC-SC 50 Micron Fiber Converter Cable (#2456) or a LC-SC 62.5 Micron Fiber Converter Cable (#2459) is required.
Refer to the following IBM storage subsystem web page for additional supported server attachment information for IBM devices.
Consult with your IBM representative or Business Partner for additional information relative to any third party attachment.
See also optional wrap plug feature #ECW0 which is:
- a) Required to run some diagnostic procedures and
- b) in some cases may speed system boot when placed in empty ports as well as avoid useless messages pointing to a planned empty port.
- Attributes provided: 1 Fibre Channel
- Attributes required: 1 Empty PCIe slot
- For 8205-E6D: (#5773)
- Minimum required: 0
- Maximum allowed: 44 (Initial order maximum: 44)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Maximum of 5 supported in the CEC.
- System maximum of 45 with 5 in the CEC and 4 x #5802/#5877.
(#5774) - 4 Gigabit PCI Express Dual Port Fibre Channel Adapter
(No Longer Available as of March 31, 2018)
The 4 Gigabit Dual Port Fibre Channel Adapter is a 64-bit address/data, short form factor PCIe adapter with an LC type external fiber connector. With the use of appropriate optical fiber cabling, this adapter provides the capability for a network of high-speed local and remote located storage. The adapter will auto-negotiate for the highest data rate between adapter and an attaching device at 1 Gbps, 2 Gbps or 4 Gbps of which the device or switch is capable. Between the adapter and an attaching device or switch, the distances supported are up to: 500 meters running at 1 Gbps data rate, 300 meters running at 2 Gbps data rate, and 150 meters running at 4 Gbps data rate. When used with IBM Fibre Channel storage switches supporting long-wave optics, distances of up to 10 kilometers are capable running at either 1 Gbps, 2 Gbps, or 4 Gbps data rates.
The 4 Gigabit PCIe Dual Port Fibre Channel Adapter can be used to attach devices either directly, or by means of Fibre Channel Switches. If attaching a device or switch with a SC type fiber connector(s), use of an LC-SC 50 Micron Fiber Converter Cable (#2456) or a LC-SC 62.5 Micron Fiber Converter Cable (#2459) is required.
Refer to the following IBM storage subsystem Web page for additional supported server attachment information for IBM devices.
Consult with your IBM representative or Business Partner for additional information relative to any third party attachment.
See also optional wrap plug feature #ECW0 which is:
- a) Required to run some diagnostic procedures and
- b) in some cases may speed system boot when placed in empty ports as well as avoid useless messages pointing to a planned empty port.
- Attributes provided: 2 Fibre Channel
- Attributes required: 1 Empty PCIe slot
- For 8205-E6D: (#5774)
- Minimum required: 0
- Maximum allowed: 44 (Initial order maximum: 44)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 5 supported in the CEC.
- System maximum of 45 with 5 in the CEC and 4 x #5802/#5877.
(#5785) - 4 Port Async EIA-232 PCIe Adapter
(No Longer Available as of March 31, 2018)
Connection for 4 asynchronous EIA-232 devices. Ports are programmable to support EIA-232 protocols, at a line speed of 128K bps. One connector on the rear of the adapter provides attachment for a fan-out cable (provided) which provides four EIA-232 ports. Note #5785 and #5277 are physically and electrically identical adapters, except for the type of PCIe slot used (full-high or low profile). Note also the 4-port #5277/5785 is functionally nearly identical to the 2-port #5289/5290 except for the number and type of connectors.
- Attributes provided: 4-Port Asynchronous EIA-232 via 4-Port DB9 DTE Fan-Out Cable 1.2 M (4 ft.), 4 x 9-pin D-Sub (Male DB-9) and 1 x 68-pin D-Sub (HD-68)
- Attributes required: 1 full high PCIe Slot
- For 8205-E6D: (#5785)
- Minimum required: 0
- Maximum allowed: 44 (Initial order maximum: 44)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- IBM i 7.1 TR11, or later
- IBM i 7.2 TR4, or later
- IBM i 7.3, or later
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 5 supported in the CEC.
- System maximum of 45 with 5 in the CEC and 4 x #5802/#5877.
(#5796) - PCI-DDR 12X Expansion Drawer
The #5796 is a four EIA unit I/O expansion drawer providing six full length, 64 bit, 3.3 volt, 266MHz PCI-X DDR slots. Blind swap cassettes are used to insert or remove the PCI-X cards. The #5796 is attached to a system using a GX Dual Port 12X Channel Attach adapter in a 12X loop. Either a 12X Short Run adapter (6446) or 12X Long Run adapter (6457) must be selected on each #5796. Up to four #5796 can be attached on the same 12X loop using a mixture of Short Run and Long Run adapters.
The #5796 includes redundant hot-swap power and cooling. The blind swap PCI mechanism allows for PCI card concurrent maintenance without removing the I/O expansion drawer. The #5796 mounts in a 19-inch rack using a #7314 I/O Drawer Mounting Enclosure. Two #5796 drawers can be mounted side by side in a single #7314 using a total of four EIA. The #5796 are not required to be attached to the same system. Each #5796 requires two power cords
When placed in an IBM i partition, these PCI-X DDR slots support only smart IOAs and do not support an IOP or an IOA which requires an IOP.
- Attributes provided: 6 PCI-X DDR slots for blind swap I/O adapters
- Attributes required: Rack space in a #7314 I/O Drawer Mounting Enclosure. 12X cable(s). 12X Short Run or Long Run card, and SPCN cable(s).
- For 8205-E6D: (#5796)
- Minimum required: 0
- Maximum allowed: 8 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5802) - 12X I/O Drawer PCIe, SFF disk
(No Longer Available as of March 31, 2018)
This feature provides a 4U high I/O drawer containing ten PCIe slots and eighteen SAS hot-swap Small Form Factor disk bays. This drawer attaches to the central electronics complex via 12X DDR cables (#1862, #1864, or #1865). When SFF disks are installed, they are driven by at least one SAS PCIe adapter and SAS AT cable (#3688). Using a mode switch the 18 SFF slots can be configured as one group of 18 slots (AIX/Linux) or two groups or 9 slots (AIX/IBM i/Linux) or four groups of 4 or 5 slots (AIX/Linux).
- Attributes provided: 10 PCIe Slots, 18 SFF SAS disk bays
- Attributes required: Available 12X connection ports.
- For 8205-E6D: (#5802)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#5805) - PCIe 380MB Cache Dual - x4 3 Gb SAS RAID Adapter
(No Longer Available as of May 13, 2016)
The#5805 PCIe 380 MB Cache Dual - x4 3 Gb SAS RAID Adapter is a short, full high form factor adapter that supports the attachment of SAS disk and SAS solid state drives (SSD) using a pair of mini SAS 4x connectors. Write cache can provide an I/O performance boost even if RAID 5/6/10 is not used. From a high-level perspective, except for having a larger write cache, it is very similar to the feature 5902 PCI-X SAS adapter and provides a high-performance connection to SAS devices. Two of feature 5805 provides for mirrored write cache data and mirrored RAID parity footprints between the adapters for superior availability. Feature 5805 is installed in pairs, allowing for redundancy of the write cache. If the feature 5805 pairing is broken, then write cache is disabled. The #5805 can also be paired with a #5903 adapter.
Feature 5805 supports SAS disk drives (HDD) and SAS-bay-based SSD located in a PCIe 12X I/O Drawer or drives located in an EXP 12S Disk Drawer or EXP24S Disk Drawer. AIX/Linux formatted SAS drives can be attached, and RAID 0, RAID 5, RAID 6, and RAID 10 are supported. Similarly, IBM i RAID formatted HDD and SSD can also also be attached, and RAID 5 and RAID 6 is support. AIX, IBM i and Linux also support The #5805 is electronically identical to the #5903 and both the 5903 and 5805 use CCIN number is 574E. The #5805 adapter is slightly more narrow than the #5903 due to the placement of its cache batteries.
With proper cabling and configuration, multiple wide ports are used to provide redundant paths to each dual port SAS disk or SSD.. The adapter manages SAS path redundancy and path switching should a SAS drive failure occur. The pairing of #5805 provides a high availability I/O configuration to protect against the failure of a SAS adapter. SAS X cables attach SAS disk drives in an EXP 12S and/ or EXP24S Disk Drawer. SAS #3688 cables attach SFF SAS drives in an PCIe 12X I/O Drawer. The high availability I/O configuration connection is provided via the internal wiring within the PCIe 12X I/ O drawer itself.
Limitation: 4k byte sector HDD/SSD are not supported. Only 5xx byte sector drives are supported on this generation of PCIe adapter.
Highlights:
- Supports up to 48 SAS disks, when configured with four #5886 EXP 12S Disk Drawers or two #5887/EL1S EXP24S Disk Drawer
- SAS speed = 3 Gbs
- SAS Serial SCSI Protocol (SSP)and Serial Management Protocol (SMP)
- 380 MB of non-volatile fast write cache can increase disk subsystem performance
- Dual controller supports mirrored write cache data and mirrored RAID parity footprints
- Concurrent Firmware Update
- Attributes provided: Eight physical links via two mini SAS 4x connectors
- Attributes required: Configuration always requires even pairs of #5805 (or #5903/5805). SAS Media devices are not supported. When attaching #5886 EXP12S or #5887/EL1S EXP24S at least one of the following SAS (X) cables #3661, #3662 or #3663 must be used
- For 8205-E6D: (#5805)
- Minimum required: 0
- Maximum allowed: 44 (Initial order maximum: 44)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 5 supported in the CEC.
- System maximum of 45 with 5 in the CEC and 4 x #5802/#5877.
Each pair can support up to 40 disk (18 SFF disk plus up to 24 SAS disk) when configured with #5802 a 19-inch PCIe 12X I/O Drawer and two #5886 EXP 12S Disk Drawers.
(#5877) - 12X I/O Drawer PCIe, No Disk
(No Longer Available as of March 31, 2018)
This feature provides a 4U high I/O drawer containing ten PCIe slots. This drawer attaches to the central electronics complex via 12X DDR cables (#1862, #1864 or #1865).
- Attributes provided: 10 PCIe Slots
- Attributes required: Available 12X connection ports.
- For 8205-E6D: (#5877)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#5886) - EXP 12S Expansion Drawer
EXP 12S is an expansion drawer with twelve 3.5-inch form factor SAS bays. #5886 Supports up to 12 hot-swap SAS Hard Disk Drives (HDD) or up to 8 hot-swap Solid State Drives (SSD). The EXP 12S includes Redundant AC power supplies and two power cords. Though the drawer is one set of 12 drives which is run by one SAS controller or one pair of SAS controllers, it has two SAS attachment ports and two Service Managers for redundancy. The EXP 12S takes up a 2 EIA space in a 19-inch rack. The SAS controller can be a SAS PCI-X or PCIe adapter or pair of adapters or can be an imbedded SAS controller in server with an imbedded SAS port such as the 8203 or 8204. Attachment to the controller is via the appropriate external SAS cables. A pair of #5886 EXP12S drawers can be attached together with SAS cables allowing the SAS controller(s) to access 24 SAS bays.
- Attributes provided: 12 SAS bays, slot filler panels are provided for empty bays when initially shipped from IBM.
- Attributes required:
- Available SAS controller (PCI or embedded server controller)
- Power System server, POWER5 or later
- Available 2U 19-inch rack space
- For 8205-E6D: (#5886)
- Minimum required: 0
- Maximum allowed: 28 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5887) - EXP24S SFF Gen2-bay Drawer
(No Longer Available as of March 31, 2018)
The EXP24S SFF Gen2-bay Drawer is an expansion drawer with twenty- four 2.5-inch form factor SAS bays. #5887 supports up to 24 hot-swap SFF SAS Hard Disk Drives (HDD). It uses only 2 EIA of space in a 19-inch rack. The EXP24S includes redundant AC power supplies and two power cords. The EXP24S SFF bays use Gen-2 or SFF-2 SAS bays that are not compatible with CEC SFF Gen-1 SAS bays or with #5802/ 5803 SFF SAS bays.
With AIX/Linux/VIOS, the EXP24S can be ordered with four sets of 6 bays, two sets of 12 bays or one set of 24 bays (mode 4, 2 or 1). With IBM i the EXP24S can be ordered as one set of 24 bays (mode 1).
The EXP24S SAS ports are attached to SAS controller(s) which can be a SAS PCI-X or PCIe adapter or pair of adapters. The EXP24S can also be attached to an imbedded SAS controller in a server with an imbedded SAS port. Attachment between the SAS controller and the EXP24S SAS ports is via the appropriate SAS Y or X cables.
- Attributes provided: 24 SFF SAS bays, slot filler panels are provided for empty bays when initially shipped from IBM. #5887 rails have some adjustability for depth - 25.25 to 29.875 inches.
- Attributes required:
- Available SAS controller (PCI or imbedded server controller)
- Power System server, POWER6 or later
- Available 2U 19-inch rack space
- Appropriate SAS cables for configuration mode selected
- For 8205-E6D: (#5887)
- Minimum required: 0
- Maximum allowed: 14 (Initial order maximum: 14)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#5899) - PCIe2 4-port 1GbE Adapter
(No Longer Available as of March 31, 2018)
This short PCIe Gen2 adapter provides four 1Gb Ethernet ports that can be configured to run at 1000, 100 or 10 Mbps. 4-pair CAT-5 Unshielded Twisted Pair (UTP) cables up to 100 meters in length are attached to the copper RJ45 connectors. Each port is independent of one another and supports full-duplex or half-duplex. 1000 Mbps speed is not supported in Half Duplex (HDX) mode.
Feature #5260 and #5899 are electronically identical and have the same CCIN of 576F. #5260 indicates a low profile tail stock while #5899 indicates a full high tail stock.
Details for the ports include: for 5260 & 5899
- AIX NIM support
- IEEE 802.3ab (1 GbE), 802.1p priority, 802.1Q VLAN tagging, 802.3x flow control, 802.3ad load-balancing and failover,
- Link aggregation, IEEE 802.3ad 802.3
- Multiple MAC addresses per interface
- MSI-X, MSI and support of legacy pin interrupts
- Ether II and IEEE 802.3 encapsulated frames
- Jumbo frames up to 9.6 Kbytes
- TCP checksum offload for IPv4 and IPv6
- TCP segmentation Offload (TSO) for IPv4 and IPv6
- UDP checksum offload for IPv4 and IPv6
- AIX, IBM i and Linux provide software iSCSI support through the adapter. Linux can also leverage adapter hardware support including initiator and header & data digest (CRC) generation and checking
- Attributes provided: Four-port 1 Gb Ethernet
- Attributes required: 1 Full High Profile PCIe slot (Gen1 or Gen2)
- For 8205-E6D: (#5899)
- Minimum required: 0
- Maximum allowed: 45 (Initial order maximum: 45)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 6 supported in the CEC.
- System maximum of 46 with 6 in the CEC and 4 x #5802/#5877.
(#5900) - PCI-X DDR Dual -x4 SAS Adapter
The PCI-X DDR Dual Connector x4 SAS Adapter is a low-profile short form factor adapter and is an excellent solution for high-performance applications. The Adapter provides two SAS channels (busses). In a wide configuration, providing redundant ports to the devices, 1 Gbs throughput is supported. In the non-redundant configuration up to 3 Gbs is supported. The adapter supports RAID level 0 (with mirroring) and 10.
Highlights
- Wide Configuration supports addressing up to 512 SAS devices with eight ports
- Non-Redundant configuration supports addressing 128 SAS devices per port
- SAS speed = 3Gbs
- SATA speed = 1.5 Gbs
- SAS Serial SCSI Protocol (SSP), Serial ATA Tunneling Protocol (STP) and Serial Management Protocol (SMP)
- RAID 0 (with mirroring), 10
- Concurrent Firmware Update
- Removable Media Device Supported
- Attributes provided: Eight SAS Ports through two x4 SAS channels.
- Attributes required: One PCI-X 2.0 DDR slot
- For 8205-E6D: (#5900)
- Minimum required: 0
- Maximum allowed: 48 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC.
- System maximum of 48 with 8 x #5796.
(#5901) - PCIe Dual-x4 SAS Adapter
(No Longer Available as of March 31, 2018)
The #5901 PCIe Dual-4x SAS Adapter is a low-profile short form factor adapter which supports the attachment of SAS disk, tape, and DVD using a pair of mini SAS 4x connectors. From a high level perspective, it is functionally equivalent to the #5912 PCI-X SAS adapter and provides a high-performance connection to SAS devices.
The #5901 supports external SAS tape drives such as the 36/72 GB DAT72, 80/160 GB DAT160, and 800/1600 GB LTO-4 found in the IBM tape units such as the 7214-1U2, TS2240, TS2340, TS3100, TS3200, and TS3310. Other removable media devices supported include IBM SAS/SATA DVD-ROM/RAM drives. SAS adapter-to-enclosure (AE) cables are used to attach these drives.
The #5901 supports SAS SFF disk drives located in a PCIe 12X I/O Drawer or SAS disk drives located in an EXP 12S or EXP24S Disk Drawer or drives in a Power6 system CEC (split DASD backplane). AIX/ Linux formatted SAS drives are supported with RAID 0 (with mirroring) and RAID 10. IBM i formatted SAS drives are supported and data spreading and mirroring functions are provided by IBM i. RAID-5 or RAID-6 are not supported on the #5901. #5901 has zero write cache. CCIN for #5901 is 57B3.
With proper cabling and configuration, multiple wide ports are used to provide redundant paths to each dual port SAS disk . The adapter manages SAS path redundancy and path switching should a SAS drive failure occur. SAS Y cables attach SAS disk drives in an EXP12S or EXP24S Disk Drawers. SAS #3688 cables attach SFF SAS drives in an PCIe 12X I/O Drawer. With the EXP12S or EXP24S Drawer, a high availability I/O configuration can be created using a pair of #5901 adapters and SAS X cables to protect against the failure of a SAS adapter. In the PCIe 12X I/O Drawer, this function is provided via the internal wiring within the drawer itself.
Limitation: 4k byte sector HDD/SSD are not supported. Only 5xx byte sector drives are supported on this generation of PCIe adapter.
Highlights:
- Supports up to 48 SAS disks, when configured with four #5886 EXP12S Disk Drawers or two #5887/#EL1S EXP24S Disk Drawers
- Supports up to 42 disk (18 SFF disk plus up to 24 3.5-inch SAS disk) when configured with a #5802/#EL36 19-inch PCIe 12X I/O Drawer and two #5886 EXP 12S Disk Drawers or configured with a #5802/#EL36 and one #5887/#EL1S EXP24S
- Supports up to 50 disk (26 SFF disk plus up to 24 3.5-inch SAS disk) when configured with a #5803 24-inch PCIe 12X I/O Drawer and two #5886 EXP 12S Disk Drawers or configured with a #5803 and one #5887/#EL1S EXP24S
- SAS speed = 3 Gbs
- SATA speed = 1.5 Gbs
- SAS Serial SCSI Protocol (SSP), Serial ATA Tunneling Protocol (STP) and Serial Management Protocol (SMP)
- Dual controller supports mirrored RAID parity footprints
- Concurrent firmware update
- Attributes provided: Eight physical links via two mini SAS 4x connectors
- Attributes required: One PCI Express slot
- For 8205-E6D: (#5901)
- Minimum required: 0
- Maximum allowed: 44 (Initial order maximum: 44)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 5 supported in the CEC.
- System maximum of 45 with 4 in the CEC and 4 x #5802/#5877.
(#5902) - PCI-X DDR Dual - x4 3Gb SAS RAID Adapter
The PCI-X DDR Dual - x4 3Gb SAS RAID Adapter is a long form factor adapter and is an excellent solution for high-performance applications requiring two adapters. Two #5902 provides for mirrored write cache data and mirrored RAID parity footprints between the adapters for superior availability. With proper cabling, multiple wide ports are used to provide redundant paths to each dual port SAS disk. The adapter manages SAS path redundancy and path switching should a SAS failure occur. RAID levels 0, 5, 6, and 10 are supported. It is used with FC 5886 EXP 12S SAS disk expansion drawers. FC 5902 is always to be in used in a High Availability configuration using two adapters.
Highlights
- Supports up to 48 SAS disks, when configured with four FC 5886 12S disk expansion drawers
- SAS speed = 3Gbs
- SAS Serial SCSI Protocol (SSP)and Serial Management Protocol (SMP)
- RAID 0, 5, 6, and 10
- 175MB of NV Fast Write Cache
- Dual controller supports mirrored write cache data and mirrored RAID parity footprints
- Concurrent Firmware Update
- Attributes provided: Eight physical links via two mini SAS 4x connectors.
- Attributes required: One PCI-X 2.0 DDR slot per #5902. Configuration always requires even pairs of #5902. SAS Media devices are not supported. When attaching #5886 EXP 12S use one of the following SAS (X) cables #3661, #3662 or #3663 must be used.
- For 8205-E6D: (#5902)
- Minimum required: 0
- Maximum allowed: 48 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC.
- System maximum of 48 with 8 x #5796.
(#5908) - PCI-X DDR 1.5GB Cache SAS RAID Adapter (BSC)
(No Longer Available as of July 11, 2014)
PCI-X DDR 1.5GB Cache SAS RAID Adapter provides disk controller drive or SSD controller function using PCI-X DDR technology, a maximum of 1.5GB compressed write cache and a maximum 1.6GB compressed read cache. Auxiliary write cache and concurrent battery maintenance are provided. The controller is implemented using two physical cards that are firmly connected and requires two adjacent PCI slots. It provides three mini-SAS 4x connectors for the attachment of SAS drives located in a #5886 EXP12S/#5887 EXP24S Expansion Drawers. The controller supports a maximum of five SAS #5886 EXP12S Expansion Drawers. The controller supports a maximum of two #5887 EXP24S drawers, but can also support a #5886 I/O drawer in addition to the two #5887 providing a total of 60 SAS bays. It supports up to 6 drive slots in one POWER6 560/570/770 CEC drawers and up to three POWER6 560/570/770 drawers in the same server. With proper cabling and configuration, multiple wide ports are used to provide redundant paths to each dual port SAS disk or SSD. The adapter manages SAS path redundancy and path switching should a SAS drive failure occur. CCIN is 572F/575C.
The adapter provides RAID 0, RAID 5, RAID 6 and RAID 10 for AIX linux. Under IBM i OS, mirroring and data spreading is provided by the operating system and RAID 5 and RAID6 is provided by the adapter.
#5904, #5906 and #5908 are all feature codes representing the same physical cards, but different feature codes are used to indicate if a blind swap cassette is used and its type. #5908 indicates a Gen-3 blind swap cassette used in enclosures such as the 19-inch #5790, 5796 or Power 570 CEC.
With the optional pairing of adapters, an even higher level of protection beyond, auxiliary cache is provided via a dual controller I/O configuration to protect against the failure of an entire adapter. In such a high availability I/O configuration, SAS X cables are used to attach #5886 EXP12S/#5887 EXP24S Expansion Drawers and the 4th mini-SAS connector (top) is used with an adapter to adapter (AA) SAS CABLE, (3M #3681, 6M #3682), to directly connect the card sets. Paired adapters must reside on the same server/partition for IBM i, but can be in the same or separate servers/partitions for AIX/ Linux.
Highlights
- SAS speed = 3Gb/s
- SAS-SSP, SMP are supported
- Supports Single controller with SAS y cables( #3692, #3693, #3694) for #5886 EXP12S/#5887 EXP24S or with SAS AI cables for Power 560/570 CEC
- Supports Dual controller with SAS x cables (#3661, #3662, #3663) and SAS (AA) cable(#3681 or #3682).
- Built-in auxiliary cache mirrors write cache for redundancy
- Attributes provided: PCI-X DDR 1.5GB Cache SAS RAID Adapter
- Attributes required: two adjacent PCI-X slots, if paired controller use either #3681 or #3682 (AA) cables.
- For 8205-E6D: (#5908)
- Minimum required: 0
- Maximum allowed: 16 (Initial order maximum: 16)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Not supported in the CEC.
- System maximum is 16 in 8 x #5796
(#5912) - PCI-X DDR Dual - x4 SAS Adapter
The PCI-X DDR Dual Connector x4 SAS Adapter is a low-profile short form factor adapter and is an excellent solution for high-performance applications. With proper cabling, multiple wide ports are used to provide redundant paths to each dual port SAS disk. The adapter manages SAS path redundancy and path switching should a SAS failure occur. RAID levels 0 and 10 are supported. FC 5912 may also be used in a High Availability configuration using two adapters.
Highlights
- Supports up to 48 SAS disks, when configured with four FC 5886 12S disk expansion drawers
- Removable Media Device Supported
- SAS speed = 3Gbs
- SATA speed = 1.5Gbs
- SAS Serial SCSI Protocol (SSP), Serial ATA Tunneling Protocol (STP) and Serial Management Protocol (SMP)
- RAID 0 and 10
- Dual controller supports mirrored RAID parity footprints
- Concurrent Firmware Update
- Attributes provided: Eight physical links via two mini SAS 4x connectors
- Attributes required: One PCI-X 2.0 DDR slot
- For 8205-E6D: (#5912)
- Minimum required: 0
- Maximum allowed: 48 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC.
- System maximum of 48 with 8 x #5796.
(#5913) - PCIe2 1.8 GB Cache RAID SAS Adapter Tri-port 6 Gb
(No Longer Available as of December 31, 2016)
The PCIe2 1.8 GB Cache RAID SAS Adapter Tri-port 6 Gb (#5913) provides high performance HDD or SSD controller function using PCIe Gen2 technology. HDD and SSD can be either SFF or 3.5-inch drives (or both). A pair of adapters are required to provide mirrored write cache data and adapter redundancy. Integrated flash memory provides protection of the write cache without batteries in case of power failure.
The #5913 provides three Mini-SAS HD (high density) connectors for the attachment of SAS drives located in the #5887/EL1S EXP24S, #5886 EPX12S, or #5802/5803/EL36 12X PCIe I/O drawers. X, YO or AT SAS cables with HD connectors are used to attach to these drawers. A max of 3 EXP24S or 6 EXP12S can be attached. If controlling drives in a #5802/5803/EL36 the #5913 pairs must be located in that #5802/ 5803/EL36. An AA SAS cable with HD connectors is attached to the #5913 pair to communicate status and cache content information and is required unless all three ports are being used to attach I/O drawers.
The #5913 provides RAID 0, RAID 5, RAID 6 and RAID 10 for AIX and Linux and VIOS. The adapter provides RAID 5 and RAID 6 for IBM i. IBM i provides both OS mirroring and data spreading. AIX/Linux/VIOS provide OS mirroring (LVM). The adapter's CCIN is 57B5.
Limitation: 4k byte sector HDD/SSD are not supported. Only 5xx byte sector drives are supported on this generation of PCIe adapter
- Attributes provided: PCIe2 1.8 GB Cache RAID SAS Adapter
- Attributes required: One PCIe slot per #5913
- For 8205-E6D: (#5913)
- Minimum required: 0
- Maximum allowed: 34 (Initial order maximum: 34)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 2 in the CEC
- System maximum of 34
- For performance when more than four are in a #5802 or #5887 we recommend only one loop per drawer
(#5915) - SAS AA Cable 3m - HD 6Gb Adapter to Adapter
This 3 meter SAS cable connects a pair of SAS adapters to each other. This AA cable has two Mini-SAS HD (High Density)connectors which connect the top connectors of two #5913 1.8GB RAID SAS Adapters. The cable provides a high performance path of all the dual controller communication including mirroring the write cache and status awareness of each card. This cable can support up to 6Gb throughput.
An AA cable is always required between a pair of #5913 adapters unless all six (three pair) of ports are used to attach I/O drawers. If an AA cable fails or is disconnected, then the information it was carrying is then sent over the cables attached to the I/O drawers, sharing their bandwidth.
Multiple cable length feature codes are available. Choose the cable length that best matches the distance between the two adapters.
- Attributes provided: high speed connection between two #5913 SAS adapters
- Attributes required: available top connectors on pair of #5913 SAS adapters
- For 8205-E6D: (#5915)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#5916) - SAS AA Cable 6m - HD 6Gb Adapter to Adapter
This 6 meter SAS cable connects a pair of SAS adapters to each other. This AA cable has two Mini-SAS HD (High Density)connectors which connect the top connectors of two #5913 1.8GB RAID SAS Adapters. The cable provides a high performance path of all the dual controller communication including mirroring the write cache and status awareness of each card. This cable can support up to 6Gb throughput.
An AA cable is always required between a pair of #5913 adapters unless all six (three pair) of ports are used to attach I/O drawers. If an AA cable fails or is disconnected, then the information it was carrying is then sent over the cables attached to the I/O drawers, sharing their bandwidth.
Multiple cable length feature codes are available. Choose the cable length that best matches the distance between the two adapters.
- Attributes provided: high speed connection between two #5913 SAS adapters
- Attributes required: available top connectors on pair of #5913 SAS adapters
- For 8205-E6D: (#5916)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#5917) - SAS AA Cable 1.5m - HD 6Gb Adapter to Adapter
This 1.5 meter SAS cable connects a pair of SAS adapters to each other. This AA cable has two Mini-SAS HD (High Density)connectors which connect the top connectors of two #5913 1.8GB RAID SAS Adapters. The cable provides a high performance path of all the dual controller communication including mirroring the write cache and status awareness of each card. This cable can support up to 6Gb throughput.
An AA cable is always required between a pair of #5913 adapters unless all six (three pair) of ports are used to attach I/O drawers. If an AA cable fails or is disconnected, then the information it was carrying is then sent over the cables attached to the I/O drawers, sharing their bandwidth.
Multiple cable length feature codes are available. Choose the cable length that best matches the distance between the two adapters.
- Attributes provided: high speed connection between two #5913 SAS adapters
- Attributes required: available top connectors on pair of #5913 SAS adapters
- For 8205-E6D: (#5917)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#5918) - SAS AA Cable 0.6m - HD 6Gb Adapter to Adapter
This 0.6 meter SAS cable connects a pair of SAS adapters to each other. This AA cable has two Mini-SAS HD (High Density)connectors which connect the top connectors of two #5913 1.8GB RAID SAS Adapters. The cable provides a high performance path of all the dual controller communication including mirroring the write cache and status awareness of each card. This cable can support up to 6Gb throughput.
An AA cable is always required between a pair of #5913 adapters unless all six (three pair) of ports are used to attach I/O drawers. If an AA cable fails or is disconnected, then the information it was carrying is then sent over the cables attached to the I/O drawers, sharing their bandwidth.
Multiple cable length feature codes are available. Choose the cable length that best matches the distance between the two adapters.
- Attributes provided: high speed connection between two #5913 SAS adapters
- Attributes required: available top connectors on pair of #5913 SAS adapters
- For 8205-E6D: (#5918)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#5922) - Non-paired SAS RAID indicator
Feature 5922 must be added for every instance of a non-paired SAS RAID adapter #5902. It identifies a specific high availability configuration supported by AIX or Linux which has one #5902 on one system and the paired #5902 located on a second system.
Limitation: IBM i systems must have both adapters on the same server.
- Attributes provided: SAS RAID adapter firmware disables write cache until a second SAS RAID adapter is recognized.
- Attributes required: Every #5922 requires a SAS RAID adapter on both this server and on another server that will pair up the SAS RAID adapter and enable the onboard caches to function.
- For 8205-E6D: (#5922)
- Minimum required: 0
- Maximum allowed: 48 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5923) - Non-paired PCIe SAS RAID Indicator
Feature 5923 must be added for every instance of a non-paired SAS RAID adapter #5903. It identifies a specific high availability configuration supported by AIX or Linux which has one #5903 on one system and the paired #5903 located on a second system. IBM i does not support paired adapter on different servers.
- Attributes provided: SAS RAID adapter firmware disables write cache until a second SAS RAID adapter is recognized.
- Attributes required: Every #5923 requires a SAS RAID adapter (#5903) on both this server and on another server that will pair up the SAS RAID adapter and enable the onboard caches to function.
- For 8205-E6D: (#5923)
- Minimum required: 0
- Maximum allowed: 44 (Initial order maximum: 44)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#5924) - Non-paired Indicator 5913 PCIe SAS RAID Adapter
Feature 5924 must be added for every instance of a non-paired SAS RAID adapter #5913. It identifies a specific high availability configuration supported by AIX or Linux which has one #5913 on one system and the paired #5913 located on a second system. IBM i does not support paired adapter on different servers.
- Attributes provided: SAS RAID adapter firmware disables write cache until a second SAS RAID adapter is recognized.
- Attributes required: Every #5924 requires a 6Gb/s SAS RAID adapter (#5913) on both this server and on another server that will pair up the SAS RAID adapter and enable the onboard caches to function.
- For 8205-E6D: (#5924)
- Minimum required: 0
- Maximum allowed: 34 (Initial order maximum: 34)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#5925) - Shared EXP30 Indicator
Feature 5925 indicates an EXP30 Ultra SSD I/O Drawer is attached to two different servers. Only one GX++ PCIe connection is planned for the server on which this feature is ordered. The second GX++ PCIe connection is planned for a second server. Note the EXP30 with only one GX++ PCIe connections in place will not use the write cache in its integrated SAS controllers. See also #5927.
- Attributes provided: Indicator to IBM configurator and manufacturing tools
- Attributes required: Attachment to a second server ordered separately
- For 8205-E6D: (#5925)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i - not supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#5926) - SAS EX Cable 1.5m - Drawer to Drawer
The SAS EX Cable is a straight line cable with a HD SAS connector on one end and a mini SAS connector on the other end. The cable is rated at 6 Gbps. A pair of these cables connects the EXP30 Ultra SSD I/O Drawer (#EDR1) to an EXP24S I/O Drawer (#5887).
Select the length appropriate to your configuration. #5926 is 1.5m. #3675 is 3m, #3680 is 6m.
- Attributes provided: Cable
- Attributes required: None
- For 8205-E6D: (#5926)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#5927) - Remote EXP30 Indicator
Feature 5927 indicates a GX++ slot's use is planned for a GX++ PCIe adapter which will be attached to an EXP30 Ultra SSD I/O Drawer which is ordered with another server. See also #5925.
- Attributes provided: Indicator to IBM configurator and manufacturing tools
- Attributes required: GX++ PCIe Adapter to attach to an EXP30 Ultra Drawer ordered on a separately ordered server
- For 8205-E6D: (#5927)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i - not supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#5951) - Full Width Keyboard -- USB, US English, #103P
This feature provides a USB attached US English #103P Quiet Touch keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#5951)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5952) - Full Width Keyboard -- USB, French, #189
This feature provides a USB attached French #189 Quiet Touch keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#5952)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5953) - Full Width Keyboard -- USB, Italian, #142
This feature provides a USB attached Italian #142 Quiet Touch keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#5953)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5954) - Full Width Keyboard -- USB, German/Austrian, #129
This feature provides a USB attached German/Austrian #129 Quiet Touch keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#5954)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5955) - Full Width Keyboard -- USB, UK English, #166P
This feature provides a USB attached UK English #166 Quiet Touch keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#5955)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5956) - Full Width Keyboard -- USB, Spanish, #172
This feature provides a USB attached Spanish #172 Quiet Touch keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#5956)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5957) - Full Width Keyboard -- USB, Japanese, #194
This feature provides a USB attached Japanese #194P Quiet Touch keyboard. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#5957)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5958) - Full Width Keyboard -- USB, Brazilian Portuguese, #275
This feature provides a USB attached Brazilian Portuguese #275 Quiet Touch keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#5958)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5959) - Full Width Keyboard -- USB, Hungarian, #208
This feature provides a USB attached Hungarian #208 Quiet Touch keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#5959)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5960) - Full Width Keyboard -- USB, Korean, #413
This feature provides a USB attached Korean #413 Quiet Touch keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#5960)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5961) - Full Width Keyboard -- USB, Chinese, #467
This feature provides a USB attached Chinese #467 Quiet Touch keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#5961)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5962) - Full Width Keyboard -- USB, French Canadian, #445
This feature provides a USB attached French Canadian #445 Quiet Touch keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#5962)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5964) - Full Width Keyboard -- USB, Belgian/UK, #120
This feature provides a USB attached Belgian/UK #120 Quiet Touch keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#5964)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5965) - Full Width Keyboard -- USB, Swedish/Finnish, #153
This feature provides a USB attached Swedish/Finnish #153 Quiet Touch keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#5965)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5966) - Full Width Keyboard -- USB, Danish, #159
This feature provides a USB attached Danish #159 Quiet Touch keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#5966)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5967) - Full Width Keyboard -- USB, Bulgarian, #442
This feature provides a USB attached Bulgarian #442 Quiet Touch keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#5967)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5968) - Full Width Keyboard -- USB, Swiss/French/German, #150
This feature provides a USB attached Swiss, French/German #150 /F/G Quiet Touch keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#5968)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5969) - Full Width Keyboard -- USB, Norwegian,#155
This feature provides a USB attached Norwegian #155 Quiet Touch keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#5969)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5970) - Full Width Keyboard -- USB, Dutch, #143
This feature provides a USB attached Dutch #143 Quiet Touch keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#5970)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5971) - Full Width Keyboard -- USB, Portuguese, #163
This feature provides a USB attached Portuguese #163 Quiet Touch keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#5971)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5972) - Full Width Keyboard -- USB, Greek, #319
This feature provides a USB attached Greek #319 Quiet Touch keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#5972)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5973) - Full Width Keyboard -- USB, Hebrew, #212
This feature provides a USB attached Hebrew #212 Quiet Touch keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#5973)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5974) - Full Width Keyboard -- USB, Polish, #214
This feature provides a USB attached Polish #214 Quiet Touch keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#5974)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5975) - Full Width Keyboard -- USB, Slovakian, #245
This feature provides a USB attached Slovakian #245 Quiet Touch keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#5975)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5976) - Full Width Keyboard -- USB, Czech, #243
This feature provides a USB attached Czech #243 Quiet Touch keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#5976)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5977) - Full Width Keyboard -- USB, Turkish, #179
This feature provides a USB attached Turkish #179 Quiet Touch keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#5977)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5978) - Full Width Keyboard -- USB, LA Spanish, #171
This feature provides a USB attached LA Spanish #171 Quiet Touch keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#5978)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5979) - Full Width Keyboard -- USB, Arabic, #253
This feature provides a USB attached Arabic #253 Quiet Touch keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#5979)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5980) - Full Width Keyboard -- USB, Thai, #191
This feature provides a USB attached Thai #191 Quiet Touch keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#5980)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5981) - Full Width Keyboard -- USB, Russian, #443
This feature provides a USB attached Russian #443 Quiet Touch keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#5981)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5982) - Full Width Keyboard -- USB, Slovenian, #234
This feature provides a USB attached Slovenian #234 Quiet Touch keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion. Color is Business Black.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#5982)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#5983) - Full Width Keyboard -- USB, US English Euro, #103P
This feature provides a USB attached US English EURO #103P Quiet Touch keyboard with a 3m cable. The two built-in USB ports conveniently provide for additional expansion.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#5983)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#6001) - Power Control Cable (SPCN) - 2 meter
This feature provides a two-meter power control cable.
- Attributes provided: 2M power control cable
- Attributes required: I/O drawer
- For 8205-E6D: (#6001)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#6006) - Power Control Cable (SPCN) - 3 meter
This feature provides a three-meter power control cable.
- Attributes provided: 3M power control cable.
- Attributes required: two drawers in the same rack.
- For 8205-E6D: (#6006)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#6007) - Power Control Cable (SPCN) - 15 meter
This feature provides a fifteen-meter power control cable.
- Attributes provided: 15M power control cable.
- Attributes required: I/O drawer
- For 8205-E6D: (#6007)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#6008) - Power Control Cable (SPCN) - 6 meter
This feature provides a six-meter power control cable.
- Attributes provided: 6M power control cable
- Attributes required: I/O drawer
- For 8205-E6D: (#6008)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#6029) - Power Control Cable (SPCN) - 30 meter
This feature provides a thirty-meter power control cable.
- Attributes provided: 30M power control cable.
- Attributes required: two drawers in the same rack.
- For 8205-E6D: (#6029)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: No
(#6068) - Opt Front Door for 1.8m Rack
#6068 provides an attractive black full height rack door on the #0551 19 Inch 1.8m Rack. The door is steel, with a perforated flat front surface. The perforation pattern extends from the bottom to the top of the door to enhance ventilation and provide some visibility into the rack.
- Attributes provided: Front Door
- Attributes required: #0551 19 inch 1.8m Rack
- For 8205-E6D: (#6068)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#6069) - Opt Front Door for 2.0m Rack
#6069 provides an attractive black full height rack door on the #0553 19 inch 2.0m Rack. The door is steel, with a perforated flat front surface. The perforation pattern extends from the bottom to the top of the door to enhance ventilation and provide some visibility into the rack.
- Attributes provided: Front Door
- Attributes required: #0553 19 inch 2.0 meter Rack
- For 8205-E6D: (#6069)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#6248) - 1.8m Rack Acoustic Doors
#6248 provides front and rear doors for use with the #0551 19 inch 1.8m Rack. This door kit provides additional acoustic dampening for use where a quieter environment is desired. #6248 results in a larger footprint and requires additional space.
- Attributes provided: Acoustic Door Kit
- Attributes required: #0551 19 inch 1.8m Rack
- For 8205-E6D: (#6248)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#6249) - 2.0m Rack Acoustic Doors
#6249 provides front and rear doors for use with the #0553 19 inch 2.0m Rack. This door kit provides additional acoustic dampening for use where a quieter environment is desired. #6249 results in a larger footprint and requires additional space.
- Attributes provided: Acoustic Door Kit
- Attributes required: #0553 19 inch 2.0 meter Rack
- For 8205-E6D: (#6249)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#6260) Redundant or Base Power Supply for 7031 Model D24/T24 I/O Enclosure
This feature provides an 845-watt power supply, as either the primary power supply in the system, or the secondary power supply for redundant power. Each power supply runs 100-240 V at 50/60 Hz AC operation from a main isolated/buffered/protected bus. Two power supplies (#6260) are required when three or more Ultra 320 SCSI Repeater Cards is on 7031-T24/D24 order in any combination of (#5741) and (#5742). In a two-power supply installation in the event of one power supply failure the remaining power supply, will increase the fan speed while continuing to provide power for up to twenty-four disk files. The fan noise level will be more noticeable in the T24 model. Replacing the failing supply returns the fans to normal noise levels.
- Attributes provided: AC Power Supply
- Attributes required: Available Power Supply Bay
- For 8205-E6D: (#6260)
- Minimum required: 0
- Maximum allowed: 14 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#6261) - Power Supply for 7031 Model D24/T24 I/O Enclosure
This feature provides an AC power supply, either as the primary power supply in the system, or the secondary power supply for redundant power. Each power supply, runs 100-240 V at 50/60 Hz AC operation from a main isolated/buffered/protected bus. Two power supplies (#6261) or two (#6260) are required when three or more Ultra 320 SCSI Repeater Cards is on 7031-T24/D24 order in any combination of (#5741) and (#5742). In a two-power supply installation in the event of one power supply failure the remaining power supply, will increase the fan speed while continuing to provide power for up to twenty-four disk files. The fan noise level will be more noticeable in the T24 model. Replacing the failing supply returns the fans to normal noise levels. Power supply (#6261) and (#6260) can not be intermixed.
- Attributes provided: AC Power Supply
- Attributes required: Available Power Supply Bay
- For 8205-E6D: (#6261)
- Minimum required: 0
- Maximum allowed: 14 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#6263) - 1.8m Rack Trim Kit
This feature provides a decorative trim kit for the front of feature number 0551 (19 inch 1.8m Rack).
- Attributes provided: Decorative trim kit
- Attributes required: #0551 19 inch 1.8m Rack
- For 8205-E6D: (#6263)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: n/a
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
Note: 1x#6263 per #0551
(#6272) - 2.0m Rack Trim Kit
This feature provides a decorative trim kit for the front of feature number 0553 (19 inch 2.0m Rack).
- Attributes provided: Decorative trim kit
- Attributes required: #0553 19 inch 2.0 meter Rack
- For 8205-E6D: (#6272)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: n/a
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
Note: 1X#6272 per #0553
(#6446) - Dual-port 12X Channel Interface Attach - Short Run
This Adapter is the interface for attachment of the I/O Drawer to a 12X Channel loop. The adapter includes two 12X Channel connectors to support attachment of the I/O drawer into the loop. This adapter does not include the repeater function and is intended to support configurations where the Host system and the external I/O drawers in the loop are located in the same rack.
Cables attached to this adapter have the following restrictions. Cables between this adapter and a host system may not exceed 3.0 Meters in length. Cables between two I/O Drawers may not exceed 1.5 Meters if both I/O drawers include this Short Run adapter feature #6446. Cables between two I/O Drawers may not exceed 3.0 Meters if either of the I/O drawers includes this Short Run adapter feature #6446. The required 12X Cables are ordered under a separate feature number.
- Attributes provided: 12X Channel Interface Connection
- Attributes required: none
- For 8205-E6D: (#6446)
- Minimum required: 0
- Maximum allowed: 8 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#6457) - Dual-port 12X Channel Interface Attach- Long Run
This Adapter is the interface for attachment of the I/O Drawer to a 12X Channel loop. The adapter includes two 12X channel connectors to support attachment of the drawer into the loop. This adapter includes the repeater function and can support longer cable loops allowing drawers to be located in adjacent racks. 12X Cables up to 8 Meters in length can be attached to this adapter. The required 12X Cables are ordered under a separate feature number.
- Attributes provided: 12X Channel Interface Connection
- Attributes required: none
- For 8205-E6D: (#6457)
- Minimum required: 0
- Maximum allowed: 8 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#6458) - Power Cord 4.3m (14-ft), Drawer to Wall/IBM PDU (250V/10A)
Standard IBM rack power cable that goes from the system or I/O drawer to the rack power distribution unit (PDU).
- Attributes provided: Power cable
- Attributes required: None
- For 8205-E6D: (#6458)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#6460) - Power Cord 4.3m (14-ft), Drawer To OEM PDU (125V, 15A)
This power cord goes from the system or I/O drawer to the rack power distribution unit or wall socket outlet. Plug type #4 (NEMA 5-15). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. 14-foot length. The following countries/regions use the #6460 power cord to power the system and/or peripheral features requiring a power cord: United States, Antigua & Barbuda, Aruba, Bahamas, Barbados, Belize, Bermuda, Bolivia, Bonnaire, Calicos Islands, Canada, Cayman Islands, Colombia, Costa Rica, Cuba, Curacao, Dominican Republic, Ecuador, El Salvador, Guam, Guatemala, Guyana, Haiti, Honduras, Jamaica, Japan, Mexico, Micronesia, Montserrat, Netherlands Antilles, Nicaragua, Panama, Peru, Philippines, St. Kitts/Nevis, St. Martin, Taiwan, Tortola (BVI), Trinidad/Tobago, Venezuela.
- Attributes provided: Power cord
- Attributes required: None
- For 8205-E6D: (#6460)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#6469) Power Cord 4.3m (14-ft), Drawer to Wall/OEM PDU (250V/15A) US
This power cord goes from the system or I/O drawer to the wall or rack power distribution unit. Plug type #5 (NEMA 6-15). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. 14-foot length.
The following countries/regions use the #6469 power cord to power the system and/or peripheral features requiring a power cord:
United States, Anguilla, Antigua & Barbuda, Aruba, Bahamas, Barbados, Belize, Bermuda, Bolivia, Bonnaire, Caicos Is., Canada, Cayman Islands, Colombia, Costa Rica, Cuba, Curacao, Dominican Republic, Ecuador, El Salvador, Guam, Guatamala, Haiti, Honduras, Jamaica, Japan, Micronesia, Montserrat, Netherlands Antilles, Nicaragua, Panama, Peru, Philippines, St. Marten NA, Taiwan, Tortola (BVI), Thailand, Venezuela.
- Attributes provided: Power cord
- Attributes required: None
- For 8205-E6D: (#6469)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#6470) - Power Cord 1.8m (6-ft), Drawer to Wall (125V/15A)
This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #4 (NEMA 5-15). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. 6-foot length.
The following countries/regions use the #6470 power cord to power the system and/or peripheral features requiring a power cord:
United States, Antigua and Barbuda, Aruba, Bahamas, Barbados, Belize, Bermuda, Bolivia, Bonnaire, Calicos Islands, Canada, Cayman Islands, Colombia, Costa Rica, Cuba, Curacao, Dominican Republic, Ecuador, El Salvador, Guam, Guatemala, Guyana, Haiti, Honduras, Jamaica, Japan, Mexico, Micronesia, Montserrat, Netherlands Antilles, Nicaragua, Panama, Peru, Philippines, St. Kitts/Nevis, St. Martin, Taiwan, Tortola (BVI), Trinidad/Tobago, Venezuela.
- Attributes provided: Power cord
- Attributes required: None
- For 8205-E6D: (#6470)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#6471) - Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU (125V/15A)
This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #70 (iNMETRO NBR 6147, NEMA 5-15). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types.
The following countries/regions use the #6471 power cord to power the system and/or peripheral features requiring a power cord:
Brazil
- Attributes provided: Power cord
- Attributes required: None
- For 8205-E6D: (#6471)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#6472) - Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU (250V/16A)
This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #18 (CEE 7 VII). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types.
The following countries/regions use the #6472 power cord to power the system and/or peripheral features requiring a power cord:
Afghanistan, Albania, Algeria, Andorra, Angola, Armenia, Austria, Belarus, Belgium, Benin, Bosnia/Herzegovina, Bulgaria, Burkina Faso, Burundi, Cambodia, Cameroon, Cape Verde, Central African Republic, Chad, Comoros, Conogo, Croatia, Czech Republic, Dahomey, Djibuouti, Egypt, Equatorial Guinea, Eritrea, Estonia, Etrhiopia, Finland, France, French Polynesia, French Guyana, Gabon, Georgia, Germany, Greece, Guadeloupe, Guinea, Guinea-Bissau, Hungary, Iceland, Indonesia, Iran, Ivory Coast, Kazakhstan, Krygystan, Laos, Latvia, Lebanon, Lintuania, Luxembourg, Macau, Macedonia, Mali, Martinigue, Mauritania, Mauritus, Mayotte, Moldova, Monaco, Mongolia, Morocco, Mozambique, Netherlands, New Caledonia, Niger, North Korea (C19 only), Norway, Poland, Portugal, Principe, Reunion, Romania, Russia, Rwanda, St. Thomas, Saudi Arabia, Senegal, Serbia, Slovenia, Somalia, South Korea (C19 only), Spain, Surinam, Sweden, Syria, Tahiti, Tajikistan, Togo, Tunesia, Turkey, Turkmenistan, Ukraine, Upper Volta, Uzbekistan, Vanuatu, Vietnam, Wallis & Futuna, Zaire, Zimbabwe.
- Attributes provided: Power cord
- Attributes required: None
- For 8205-E6D: (#6472)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#6473) - Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU (250V/10A)
This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #19 (CEE). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types.
The following countries/regions use the #6473 power cord to power the system and/or peripheral features requiring a power cord:
Denmark
- Attributes provided: Power cord
- Attributes required: None
- For 8205-E6D: (#6473)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#6474) - Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/13A)
This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #23 (BS 1364A). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types.
The following countries/regions use the #6474 power cord to power the system and/or peripheral features requiring a power cord:
Abu Dhabi, Bahrain, Botswana, Brunei, Channel Islands, Cyprus, Dominica, Gambia, Grenada, Grenadines, Guyana, Hong Kong, Iraq, Ireland, Jordan, Kenya, Kuwait, Liberia, Malawi, Malaysia, Malta, Myanmar, Nkigeria, Oman, Qatar, Sierra Leone, Singapore, St. Kitts, St. Lucia, Seychelles, Sudan, Tanzania, Trinidad & Tobago, United Arab Emirates, United Kingdom, Yemen, Zambia
- Attributes provided: Power cord
- Attributes required: None
- For 8205-E6D: (#6474)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#6475) - Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/16A)
This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #32 (SII 32-1971). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types.
The following countries/regions use the #6475 power cord to power the system and/or peripheral features requiring a power cord:
Israel
- Attributes provided: Power cord
- Attributes required: None
- For 8205-E6D: (#6475)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#6476) - Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/10A)
This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #24 (SEV 24507). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types.
The following countries/regions use the #6476 power cord to power the system and/or peripheral features requiring a power cord:
Lichtenstein, Switzerland
- Attributes provided: Power cord
- Attributes required: None
- For 8205-E6D: (#6476)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#6477) - Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/16A)
This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #22 (SABS 164). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types.
The following countries/regions use the #6477 power cord to power the system and/or peripheral features requiring a power cord:
Bangladesh, LeSotho, Maceo, Maldives, Nambia, Pakistan, Samoa, South Africa, Sri Lanka, Swaziland, Uganda.
- Attributes provided: Power cord
- Attributes required: None
- For 8205-E6D: (#6477)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#6478) - Power Cord 2.7 M(9-foot), To Wall/OEM PDU, (250V, 16A)
This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #25 (CEI 23-16). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. The following countries/regions use the #6478 power cord to power the system and/or peripheral features requiring a power cord: Chile Italy Libya
- Attributes provided: Power cord
- Attributes required: None
- For 8205-E6D: (#6478)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#6479) - Power Cord (9-foot), To Wall/OEM PDU, (250V, 10A)
This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #6 (AS 3112-1964 NZS 198). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. The following countries/regions use the #6479 power cord to power the system and/or peripheral features requiring a power cord: Australia Fiji Islands Kiribati Nauru New Zealand Papua New Guinea W. Samoa
- Attributes provided: Power cord
- Attributes required: None
- For 8205-E6D: (#6479)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#6488) Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (125V/15A or 250V/10A )
This power cord goes from the system and/or peripheral features to a wall-type outlet. 125V, 15A or 250V, 10A, Plug Type #2. Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types.
The following countries/regions use the #6488 power cord to power the system and/or peripheral features requiring a power cord:
Argentina, Paraguay, Uruguay.
- Attributes provided: Power cord
- Attributes required: None
- For 8205-E6D: (#6488)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#6489) - 4.3m (14-Ft) 3PH/24A 380-415V Power Cord
#6489 is a 14-FT/4.3m 3PH/24A power cable with a Type 46 plug which distributes power from a power source to a Power Distribution Unit.
- Attributes provided: power cord
- Attributes required: None
- For 8205-E6D: (#6489)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#6491) - 4.3m (14-Ft) 1PH/48A 200-240V Power Cord
#6491 is a 14-FT/4.3m 200-240V/48A power cord with a Type 46 plug which distributes power from a power source to a Power Distribution Unit.
- Attributes provided: power cord
- Attributes required: None
- For 8205-E6D: (#6491)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#6492) - 4.3m (14-Ft) 1PH/48-60A 200-240V Power Cord
#6492 is a 14-FT/4.3m 200-240V/48-60A power cord with a Type 46 plug which distributes power from a power source to a Power Distribution Unit.
- Attributes provided: power cord
- Attributes required: None
- For 8205-E6D: (#6492)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#6493) - Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/10A)
This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #62 (GB 1053). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types.
The following countries/regions use the #6493 power cord to power the system and/or peripheral features requiring a power cord:
People's Republic of China.
- Attributes provided: Power cord
- Attributes required: None
- For 8205-E6D: (#6493)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#6494) - Power Cord 2.7m (9-ft), Drawer to Wall/OEM PDU, (250V/10A)
This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #69 (IS 6538). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types.
The following countries/regions use the #6494 power cord to power the system and/or peripheral features requiring a power cord:
India
- Attributes provided: Power cord
- Attributes required: None
- For 8205-E6D: (#6494)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#6495) - Power Cord (9-foot), To Wall/OEM PDU, (250V, 10A)
This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #73. Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. The following countries/regions use the #6495 power cord to power the system and/or peripheral features requiring a power cord: Brazil
- Attributes provided: Power cord
- Attributes required: None
- For 8205-E6D: (#6495)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#6496) - Power Cord 2.7M (9-foot), To Wall/OEM PDU, (250V, 10A)
This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #66 (KETI). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. The following countries/regions use the #6496 power cord to power the system and/or peripheral features requiring a power cord: North Korea South Korea
- Attributes provided: Power cord
- Attributes required: None
- For 8205-E6D: (#6496)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#6497) - Power Cord (6-foot), To Wall/OEM PDU, (250V, 10A)
This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #10 (NEMA L6-15). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. The following countries/regions use the #6497 power cord to power the system and/or peripheral features requiring a power cord. Canada Colombia Japan Mexico United States
- Attributes provided: Power cord
- Attributes required: None
- For 8205-E6D: (#6497)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#6498) - Power Cord (6-foot), To Wall/OEM PDU, (250V, 15A)
This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #34 (RS 3720U-2). Refer to Corporate Bulletin C-B-2-43700-009 for a description of plug types. The following countries/regions use the #6498 power cord to power the system and/or peripheral features requiring a power cord: Canada Japan United States
- Attributes provided: Power cord
- Attributes required: None
- For 8205-E6D: (#6498)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#6577) - Power Cable - Drawer to IBM PDU, 200-240V/10A
This feature permits manufacturing to select the optimum PDU cable length (1.5M, 2.7M or 4.2M) for rack integration. This feature is mandatory on initial order with 7014-T00 or T42 racks. Feature is not valid on initial order with non-factory integrated feature 4650.
- Attributes provided: Power cable
- Attributes required: At least one Rack and the absence of #4650.
- For 8205-E6D: (#6577)
- Minimum required: 0
- Maximum allowed: 114 (Initial order maximum: 114)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note: 1 or 2 per I/O drawer or CEC. MES orderable for SDI's only. The MES order will ship the 14 foot cable equivalent to feature number 6458.
(#6580) - Optional Rack Security Kit
This feature provides hardware that can be added to a rack to prevent unauthorized access. It includes keyed front and rear locks for the #0551 and #0553 rack doors. It also includes two sliding bars that mount inside the left and right rack side panels. The sliding bars are accessible when the rack rear door is open. They can be moved to a position that disables the external latches on the rack side panels, and prevents removal of the side panels.
- Attributes provided: Locking hardware for rack doors and side panels
- Attributes required: #0551 or #0553 19-Inch Rack
- For 8205-E6D: (#6580)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#6586) - Modem Tray for 19-Inch Rack
(No Longer Available as of December 29, 2017)
This feature provides hardware for installing one or two modems in a 19-inch rack. The modem tray occupies 1U of rack space when it is mounted in the front of the rack. It provides a secure location in the rack for external modems such as the ones attached to the Hardware Management Console.
- Attributes provided: Hdw. to support two modems
- Attributes required: 19-inch rack with 1U rack space available
- For 8205-E6D: (#6586)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#6651) - Power Cord 2.7M (9-foot), To Wall/OEM PDU, (125V, 15A)
This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #75 (KETI). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. The following countries/regions use the #6651 power cord to power the system and/or peripheral features requiring a power cord: Taiwan
- Attributes provided: Power cord
- Attributes required: None
- For 8205-E6D: (#6651)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#6653) - 4.3m (14-Ft) 3PH/16A 380-415V Power Cord
#6653 is a 14-FT/4.3m 3PH/16A power cord with a Type 46 plug which distributes power from a power source to a Power Distribution Unit.
- Attributes provided: power cord
- Attributes required: None
- For 8205-E6D: (#6653)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#6654) - 4.3m (14-Ft) 1PH/24-30A Pwr Cord
#6654 is a 14-FT/4.3m 200-240V/24A locking power cord with a Type 12 plug which distributes power from a power source to a Power Distribution Unit.
- Attributes provided: power cord
- Attributes required: None
- For 8205-E6D: (#6654)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#6655) - 4.3m (14-Ft) 1PH/24-30A WR Pwr Cord
#6655 is a 14-FT/4.3m 200-240V/24A water-resistant power cord with a Type 40 plug which distributes power from a power source to a Power Distribution Unit.
- Attributes provided: power cord
- Attributes required: None
- For 8205-E6D: (#6655)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#6656) - 4.3m (14-Ft)1PH/24A Power Cord
#6656 is a 14-FT/4.3m 200-240V/24A power cord with a Type 46 plug which distributes power from a power source to a Power Distribution Unit.
- Attributes provided: power cord
- Attributes required: None
- For 8205-E6D: (#6656)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#6657) - 4.3m (14-Ft) 1PH/24A Power Cord
#6657 is a 14-FT/4.3m 1PH/24A power cord with a Type PDL plug which distributes power from a power source to a Power Distribution Unit.
- Attributes provided: PDU power cable
- Attributes required: None
- For 8205-E6D: (#6657)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#6659) - Power Cord 2.7M (9-foot), To Wall/OEM PDU, (250V, 15A)
This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #76 (KETI). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. The following countries/regions use the #6659 power cord to power the system and/or peripheral features requiring a power cord: Taiwan
- Attributes provided: Power cord
- Attributes required: None
- For 8205-E6D: (#6659)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#6660) - Power Cord 4.3m (14-ft), Drawer to Wall/OEM PDU (125V/15A)
This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #59 (NEMA 5-15). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. 14-foot length.
This power cord meets the DENAN marking requirement in Japan.
- Attributes provided: Power Cord
- Attributes required: None
- For 8205-E6D: (#6660)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#6665) Power Cord 2.8m (9.2-ft), Drawer to Wall/IBM PDU, (250V/10A)
Standard IBM rack power cable that goes from the system or I/O drawer to the rack power distribution unit (PDU). 2.8 M (9.2-foot) length. Use this cord with PDUs that have IEC320/C20 connectors.
- Attributes provided: Power Cord
- Attributes required: None
- For 8205-E6D: (#6665)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#6669) - Power Cord 4.3M (14-foot), Drawer to OEM PDU, (250V, 15A)
This power cord goes from the system or I/O drawer to the rack power distribution unit. Plug type #57 (NEMA 6-15). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. 14-foot length. This power cord meets the DENAN marking requirement in Japan.
- Attributes provided: Power Cord
- Attributes required: None
- For 8205-E6D: (#6669)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#6670) - Power Cord (6-foot), To Wall (125V, 15A), PT #59
This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #59 (NEMA 5-15). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. 6-foot length. This power cord meets the DENAN marking requirement in Japan.
- Attributes provided: Power cord
- Attributes required: None
- For 8205-E6D: (#6670)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#6671) - Power Cord 2.7M (9-foot), Drawer to IBM PDU, 250V/10A
Standard IBM rack power cable that goes from the system or I/O drawer to the rack power distribution unit (PDU). 9-foot length.
- Attributes provided: Power Cord
- Attributes required: None
- For 8205-E6D: (#6671)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#6672) - Power Cord 2M (6.5-foot), Drawer to IBM PDU, 250V/10A
Standard rack power cable that goes from the system or I/O drawer to the rack power distribution unit (PDU). 6.5-foot length.
- Attributes provided: Power Cord
- Attributes required: None
- For 8205-E6D: (#6672)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#6680) - Power Cord 2.7m (9-ft), Dawer to Wall/OEM PDU, (250V/10A)
This insulated power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #6 (AS 3112-1964 NZS 198). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types.
The following countries/regions use the #6680 power cord to power the system and/or peripheral features requiring a power cord:
Australia, Fiji Islands, Kiribati, Nauru, New Zealand, Papua New Guinea, W. Samoa.
- Attributes provided: Power cord
- Attributes required: None
- For 8205-E6D: (#6680)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#6687) - Power Cord (6-foot), To Wall, (250V, 15A)
This power cord goes from the system and/or peripheral features to a wall-type outlet. Plug type #57 (NEMA 6-15). Refer to Corporate Bulletin C-B-2-4700-009 for a description of plug types. 6-foot length. This power cord meets the DENAN marking requirement in Japan.
- Attributes provided: Power cord
- Attributes required: None
- For 8205-E6D: (#6687)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#6771) - Two 1M Intra-rack Fibre Channel Cables
Pair of Intra-rack Fibre Channel Cables with switch in same rack.
- Attributes provided: Two 1M Fibre Channel Cables
- Attributes required: Switch in same rack
- For 8205-E6D: (#6771)
- Minimum required: 0
- Maximum allowed: 6 (Initial order maximum: 6)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#6773) - Two 3M Intra-rack Fibre Channel Cables
Pair of Intra-rack Fibre Channel Cables with switch in same rack.
- Attributes provided: Two 3M Fibre Channel Cables
- Attributes required: Switch in same rack
- For 8205-E6D: (#6773)
- Minimum required: 0
- Maximum allowed: 6 (Initial order maximum: 6)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#6805) - PCI 2-Line WAN IOA No IOP
Feature #6805 is a 2 RVX port WAN IOA that supports multiple protocols on Asynchronous and Synchronous Mode connections
On the IBM i Operating system, the #6805 may be used either with or without an IOP.
- When under an IOP, #6805 supports PPP (Point to Point Protocol), ASC (Async), and Fax protocols on an Asynchronous Connection, and PPP, BSC (Bisync), SDLC, X.25, and FR (Frame Relay) protocols on a Synchronous Connection
- When the #6805 is IOPless, it supports PPP, ASC, and Fax protocols on an Asynchronous Connection, but only supports Synchronous PPP, and BSC (Bisync) protocols on a Synchronous Connection.
Connection With an IOP IOPless
----------------------------- ------------- -----------
Asynchronous Connection:
PPP (Point to Point Protocol) Yes Yes
ASC (Async) Yes Yes
FAX Yes Yes
Synchronous Connection:
Sync PPP Yes Yes
BSC (Bisync) Yes Yes
SDLC Yes No
X.25 Yes No
FR (Frame Relay) Yes No
The #6805 supports SNA only if configured with an IOP. If SNA is required in an IOPless environment, IBM i Enterprise Extender supports SNA over a LAN Connection and encapsulates the SNA frame within a TCP/IP frame.
The following self-configuring cables provide the physical connections to #6805:
- #0348 - V.24/EIA232 20-Ft PCI Cable
- #0349 - V.24/EIA232 50-Ft PCI Cable (support only, not orderable)
- #0353 - V.35 20-Ft PCI Cable
- #0354 - V.35 50-Ft PCI Cable (support only, not orderable)
- #0356 - V.36 20-Ft PCI Cable
- #0358 - V.36 80-Ft PCI Cable (support only, not orderable)
- #0359 - X.21 20-Ft PCI Cable
- #0360 - X.21 50-Ft PCI Cable (support only, not orderable)
- #0365 - V.24/EIA232 80-Ft PCI Cable (support only, not orderable)
- #0367 - Operations Console PCI Cable
Note: The #0367 cable ships with a 25 pin to 9 pin adapter. Multiple #0367 cables may be ordered (but only one per #6805) to serve as consoles for secondary partitions when Logical Partitioning is utilized.
When #6805 is selected to support ECS, one of following cables must be specified:
- #0348 V.24/EIA232 20-Ft PCI Cable
- #0349 V.24/EIA232 50-Ft PCI Cable (support only, not orderable)
- #0365 V.24/EIA232 80-Ft PCI Cable (support only, not orderable)
#6805 does not support remote power-on.
IOPs are not supported on POWER7 systems.
- Attributes provided: two RVX comm ports
- Attributes required: one 3V PCI/PCI-X slot
- For 8205-E6D: (#6805)
- Minimum required: 0
- Maximum allowed: 48 (Initial order maximum: 0)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC.
- System maximum of 48 with 8 x #5796.
(#6808) - PCI 4-Modem WAN IOA No IOP
The #6808 is a four-line WAN modem adapter, with four RJ-11 ports, it supports V.92 56K Async SLIP/PPP and V.34 Fax applications at data rates up to 33.6K via integrated modems. Connection to the V.92 ports is via telephone cable. The V.92 functions offer increased upload throughput, improved V.44 data compression, and shortened modem synchronization periods.
The call waiting and modem on hold functions associated with V.92 are not supported.
Remote power on via ring-indicator and SDLC are not supported.
#6808 does not support SNA communications except through the IBM i V5R4 Enterprise Extender function.
#6808 does not have complex impedance matching (CIM).
This version of the four-line WAN modem adapter does not require an I/O processor.
#6808 does not make use of an IOP.
A minimum of one modem cable must be ordered for each #6808. All modem cables installed on a system must be the same feature number.
- #1010 Modem Cable - Austria
- #1011 Modem Cable - Belgium
- #1012 Modem Cable - Africa
- #1013 Modem Cable - Israel (supported only, not orderable)
- #1014 Modem Cable - Italy
- #1015 Modem Cable - France
- #1016 Modem Cable - Germany
- #1017 Modem Cable - UK
- #1018 Modem Cable - Iceland/Sweden
- #1020 Modem Cable - HK/NZ
- #1021 Modem Cable - Fin/Nor
- #1022 Modem Cable - Netherlands
- #1023 Modem Cable - Swiss
- #1024 Modem Cable - Denmark
- #1025 Modem Cable - US/Canada
- Attributes provided: four WAN ports
- Attributes required: one PCI slot
- For 8205-E6D: (#6808)
- Minimum required: 0
- Maximum allowed: 48 (Initial order maximum: 0)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC.
- System maximum of 48 with 8 x #5796.
(#6833) - PCI 2-Line WAN w/Modem NoIOP
The #6833 is a 2-line/port WAN w/modem adapter. This feature is the non-CIM (Complex Impedance Matching) version offered in all countries except Australia and New Zealand.
Port 0 is the modem port and supports V.92 56K Async PPP, V.92 data modem, V.44 data compression, V.34 FAX modem and FAX functions, such as ECM and 2D/1D conversion. Port 0 does not provide Sync modem capabilities (SDLC and Sync PPP).
Port 1 is the RVX port and supports multiple communications protocols, including synchronous operations.
Select one of the following cables to attach to port 0(modem port):
- #1010 Modem Cable - Austria
- #1011 Modem Cable - Belgium
- #1012 Modem Cable - Africa
- #1013 Modem Cable - Israel (supported not orderable)
- #1014 Modem Cable - Italy
- #1015 Modem Cable - France
- #1016 Modem Cable - Germany
- #1017 Modem Cable - UK
- #1018 Modem Cable - Iceland/Sweden
- #1020 Modem Cable - HK/NZ
- #1021 Modem Cable - Fin/Nor
- #1022 Modem Cable - Netherlands
- #1023 Modem Cable - Swiss
- #1024 Modem Cable - Denmark
- #1025 Modem Cable - US/Canada
Select one of the following cables to attach to port 1(RVX port):
- #0348 - V.24/EIA232 20-Ft PCI Cable
- #0353 - V.35 20-Ft PCI Cable
- #0356 - V.36 20-Ft PCI Cable (supported only, not orderable)
- #0359 - X.21 20-Ft PCI Cable
- #0367 - Operations Console PCI Cable (ships with a 25 pin to 9 pin
adapter)
- Multiple #0367 cables can be ordered (but only one per #6833) to serve as consoles for secondary partitions when Logical Partitioning is utilized.
ECS is supported from both the modem port, and the RVX port. The following cable is required to support ECS from the RVX port:
- #0348 - V.24/EIA232 20-Ft PCI Cable
The #6833 does not support the remote ring indicate function.
#6833 does not support SNA communications except through IBM i V5R4 Enterprise Extender function.
- Attributes provided: One RVX port and one integrated modem port
- Attributes required: One PCI slot (3 volt)
- For 8205-E6D: (#6833)
- Minimum required: 0
- Maximum allowed: 48 (Initial order maximum: 0)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
Note:
- Not supported in the CEC.
- System maximum of 48 with 8 x #5796.
(#7109) - Intelligent PDU+, 1 EIA Unit, Universal UTG0247 Connector
This feature is for an intelligent AC power distribution unit (PDU+) that will allow the user to monitor the amount of power being used by the devices that are plugged in to this PDU+. This AC power distribution unit provides twelve C13 power outlets. It receives power through a UTG0247 connector. It can be used for many different countries and applications by varying the PDU to Wall Power Cord, which must be ordered separately. Each PDU requires one PDU to Wall Power Cord. Supported power cords include the following features: #6489, #6491, #6492, #6653, #6654, #6655, #6656, #6657, and #6658.
- Attributes provided: Twelve C13 outlets with Power Monitoring Capability
- Attributes required: none
- For 8205-E6D: (#7109)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
Note: When purchased on an MES order with a feature code rack. This PDU will be mounted in the rear side pockets until all 4 side pockets on the rack have been filled. Any additional PDUs on the order will be mounted in 1 unit of EIA rack space. When purchased as an MES order for addition to a rack in the field. This PDU may not fit in the side pockets of your rack due to a hardware interference with the rack, and may require mounting in 1 unit of rack EIA space. Insure rack space is available before placing the MES order for this PDU when it is being ordered for field installation.
(#7118) - Environmental Monitoring Probe
The Environmental Monitoring Probe (EMP) enables you to remotely monitor environmental conditions. Using a standard Web browser, you can view the ambient temperature and humidity of the remote environment, as well as the status of two additional contact devices, such as a smoke detector or open-door sensor. The temperature/humidity probe plugs into a RJ45 connector an a PDU+. The EMP can be used with any Powerware UPS equipped with a 10/100 Mb ConnectUPS Web/SNMP Card (firmware v3.01 or higher). The EMP can be located up to 20m (65.6 feet) away.
- Attributes provided: Monitoring of temperature, humidity, and status of two contacts/ sensors. A one meter cat5 Ethernet cable, double sided hook and loop fabric, often called VELCRO(R) tape, two tie-wraps, and screw with wall anchor for mounting.
- Attributes required: None
- For 8205-E6D: (#7118)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: N/A
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note: Maximum support is 8x 7118 per 0553 rack and 8x 7118 per 0551 rack. Maximum of one 7118 per 7109 is supported.
(#7131) - IBM Rack-mount Drawer Bezel and Hardware
(No Longer Available as of March 31, 2018)
Indicates that this order is for a rack-mount system requiring an IBM bezel and hardware.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#7131)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#7132) - OEM Rack-mount Drawer Bezel and Hardware
(No Longer Available as of March 31, 2018)
Indicates that this order is for a rack-mount system requiring an OEM bezel and hardware.
- Attributes provided: None
- Attributes required: Feature #7770, #7773, #7775, or #7779
- For 8205-E6D: (#7132)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#7145) - IBM/OEM Rack-mount Drawer Rail Kit
(No Longer Available as of March 31, 2018)
This feature provides a rack rail kit used to install a rack-mount system in an IBM or OEM 19-inch rack. Adjustable depth.
- Attributes provided: None
- Attributes required: Rack-mount system
- For 8205-E6D: (#7145)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#7188) - Power Distribution Unit
An AC Power Distribution Unit (PDU) which mounts in a 19" rack and provides twelve C13 power outlets. The #7188 has six 16A circuit breakers, with two power outlets per circuit breaker. System units and/or expansion units must use a power cord with a C14 plug to connect to the #7188.
One of the following line cords must be used to distribute power from a wall outlet to the #7188;
- #6489 - 14-Ft 3PH/24A Power Cord
- #6491 - 14-Ft 1PH/63A Pwr Cord
- #6492 - 14-Ft 1PH/48-60A Pwr Cord
- #6653 - 14-Ft 3PH/16A Power Cord
- #6654 - 14-Ft 1PH/24-30A Pwr Cord
- #6655 - 14-Ft 1PH/24-30A WR Pwr Cord
- #6656 - 14-Ft 1PH/32A Power Cord
- #6657 - 14-Ft 1PH/24A Power Cord
- #6658 - 14-Ft 1PH/24A Pwr Cd-Korea
- Attributes provided: Power Distribution Unit with Twelve C13 power outlets.
- Attributes required: none
- For 8205-E6D: (#7188)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#7311) - Dual I/O Unit Enclosure
(No Longer Available as of June 1, 2006)
The #7311 enclosure provides the mounting hardware required to install a #5790 I/O drawer in a #0551 or #0553 rack. The enclosure can accommodate two #5790 drawers, side by side, but it may also be used with only one #5790 drawer installed.
- Attributes provided: Rack mounting for two #5790 drawers
- Attributes required: Four EIA units of rack space in a #0551or #0553 rack
- For 8205-E6D: (#7311)
- Minimum required: 0
- Maximum allowed: 24 (Initial order maximum: 0)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#7314) - I/O Drawer Mounting Enclosure
This enclosure is required to mount the #5796 I/O drawer or 7314-G30 I/O drawer in a 19" rack. It will accommodate one or two #5796/ 7314-G30 I/O drawers side by side in the same 4 EIA space in the rack. This feature contains the hardware required for mounting in a 7014 rack or in a 0551, 0553, 0555 feature number rack.
- Attributes provided: 19" rack mounting hardware and I/O module enclosure.
- Attributes required: 4 EIA of space in a 19 inch-rack.
- For 8205-E6D: (#7314)
- Minimum required: 0
- Maximum allowed: 8 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#7517) - Quantity 150 of #3676
This feature ships a quantity of 150 #3676 disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records.
- Attributes provided: see feature #3676
- Attributes required: see feature #3676
- For 8205-E6D: (#7517)
- Minimum required: 0
- Maximum allowed: 3 (Initial order maximum: 0)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#7518) - Quantity 150 of #3677
This feature ships a quantity of 150 #3677 disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records.
- Attributes provided: see feature #3677
- Attributes required: see feature #3677
- For 8205-E6D: (#7518)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 0)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#7519) - Quantity 150 of #3678
This feature ships a quantity of 150 #3678 disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records.
- Attributes provided: see feature #3678
- Attributes required: see feature #3678
- For 8205-E6D: (#7519)
- Minimum required: 0
- Maximum allowed: 3 (Initial order maximum: 0)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#7535) - Quantity 150 of #3586
Ships a quantity 150 of #3586, 69GB 3.5" SAS Solid State Drive
- Attributes provided: 150 #3586
- Attributes required: Available 3.5-inch SAS disk bays
- For 8205-E6D: (#7535)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#7536) - Quantity 150 of #3587
This feature ships a quantity of 150 #3587 disk units. The configurator may either generate this feature. This feature remains on the inventory records.
- Attributes provided: See feature #3587
- Attributes required: See feature #3587
- For 8205-E6D: (#7536)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 0)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#7538) - Quantity 150 of #3658
This feature ships a quantity of 150 #3658 (428 GB SAS) disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records.
- Attributes provided: see feature #3658
- Attributes required: see feature #3658
- For 8205-E6D: (#7538)
- Minimum required: 0
- Maximum allowed: 3 (Initial order maximum: 0)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#7549) - Quantity 150 of #3647
Ships a quantity 150 of #3647 146GB 15K RPM SAS Disk Drive
- Attributes provided: 150 of #3647 for every #7549
- Attributes required: Available 3.5-inch SAS disk bay
- For 8205-E6D: (#7549)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#7564) - Quantity 150 of #3648
Quantity of 150 of #3648
- Attributes provided: 150 #3648 for each #7564
- Attributes required: Available 3.5-inch SAS disk bays
- For 8205-E6D: (#7564)
- Minimum required: 0
- Maximum allowed: 3 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#7565) - Quantity 150 of #3649
Quantity 150 of #3649 450GB 15K RPM SAS Disk Drive
- Attributes provided: 150 #3649
- Attributes required: Available 3.5-inch SAS disk bays
- For 8205-E6D: (#7565)
- Minimum required: 0
- Maximum allowed: 3 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#7780) - 2.0m Rack Side Attach Kit
This feature allows a row of racks without side panels to be bolted together in a continuous suite, using the provided side-to-side rack connecting hardware. When multiple racks are joined in this way, cables can be easily run between racks without exiting the continuous rack enclosure. A small gap is maintained between the two adjacent racks, which is filled by three matching steel trim pieces that snap into place on the front, top, and rear, between each rack. The trim pieces cover the space between each rack for an enhanced appearance and for additional protection of the equipment inside the racks. Side panels are needed only for the two end racks of the suite.
- Attributes provided: Hardware and trim to attach two racks
- Attributes required: #0553 rack
- For 8205-E6D: (#7780)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#7801) Ethernet Cable, 6M, Hardware Management Console to System Unit
This feature provides a six meter long Ethernet cable for attachment of a Hardware Management Console to the system unit.
- Attributes provided: 6M Ethernet Cable
- Attributes required: Ethernet port on Hardware Management Console
- For 8205-E6D: (#7801)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#7802) Ethernet Cable, 15m, Hardware Management Console to System Unit
This feature provides a fifteen meter long Ethernet cable for attachment of a Hardware Management Console to the system unit.
- Attributes provided: 15M Ethernet Cable
- Attributes required: Ethernet port on Hardware Management Console
- For 8205-E6D: (#7802)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#7840) - Side-by-Side for 1.8m Racks
This feature allows a row of racks without side panels to be bolted together in a continuous suite, using the provided side to side rack connecting hardware. When multiple racks are joined in this way, cables can be easily run between racks without having to exit the continuous rack enclosure. A small gap is maintained between the two adjacent racks, which is filled by three matching steel trim pieces that snap into place on the front, top, and rear, between each rack. The trim pieces cover the space between each rack for an enhanced appearance and for additional protection of the equipment inside the racks. Side panels are needed only for the two end racks of the suite.
- Attributes provided: Hardware and trim to attach two racks
- Attributes required: #0551 rack
- For 8205-E6D: (#7840)
- Minimum required: 0
- Maximum allowed: 12 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#7841) - Ruggedize Rack Kit
For enhanced rigidity and stability of the rack, the optional Ruggedized Rack Kit provides additional hardware that reinforces the rack and anchors it to the floor. This hardware is designed primarily for use in locations where earthquakes are a concern. The feature includes a large steel brace or truss that bolts into the rear of the rack. It is hinged on the left side so it can swing out of the way for easy access to the rack drawers when necessary. The Ruggedize Rack Kit also includes hardware for bolting the rack to a concrete floor or a similar surface, and bolt-in steel filler panels for any non-occupied spaces in the rack.
- Attributes provided: Rear brace, bolt down hardware, bolt in frontfiller panels
- Attributes required: #0551 19 inch 1.8m Rack or #0553 19 inch 2.0MRack
- For 8205-E6D: (#7841)
- Minimum required: 0
- Maximum allowed: 12 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#8143) - Linux Software Preinstall
(No Longer Available as of November 30, 2015)
This feature indicates that the Linux operating system is to be preinstalled on the system. Requires feature number 5000.
- Attributes provided: Linux preinstall
- Attributes required: Feature number 5000.
- For 8205-E6D: (#8143)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#8144) - Linux Software Preinstall (Business Partners)
(No Longer Available as of November 30, 2015)
This feature indicates that the Linux operating system is to be preinstalled on the system. Requires feature number 5000 or 7305. This feature is only available to IBM Business Partner - Solution Providers and IBM Business Partner - Systems Integrators.
- Attributes provided: Linux preinstall
- Attributes required: Feature number 5000 or 7305.
- For 8205-E6D: (#8144)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#8841) - Mouse - USB, with Keyboard Attachment Cable
This feature provides a three button USB mouse and a cable for attachment to a keyboard. Color is Business Black.
- Attributes provided: 3-Button USB Mouse
- Attributes required: Keyboard with USB Mouse Attachment Port
- For 8205-E6D: (#8841)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#8845) - USB Mouse
(No Longer Available as of October 31, 2017)
The optical LED USB Mouse has 2 buttons and a scroll wheel that acts as a third button. Mouse cable is 1.8 meters long. OS does not support scrolling with the wheel. Business black with red scroll wheel.
- Attributes provided: 2-Button USB Mouse w/scroll wheel that acts as 3rd button.
- Attributes required: USB attachment Port
- For 8205-E6D: (#8845)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#9169) - Order Routing Indicator- System Plant
(No Longer Available as of November 30, 2015)
This feature will be auto-selected by the Configurator Tool when required. Use of this feature will affect the routing of the order. Selection of this indicator will direct the order to a system plant for fulfillment.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#9169)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9300) - Language Group Specify - US English
(No Longer Available as of November 30, 2015)
English language group for nomenclature and standard publications.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#9300)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9359) - specify mode-1 1(1)5901/5278 for EXP24S #5887
Feature indicates that EXP24S SFF Gen2-bay Drawer (#5887) will be configured by IBM Manufacturing in Mode 1 (One group of 24 drive bays) with one PCIe 3G SAS controller (#5901 or #5278), utilizing one appropriate YO cable connecting to the I/O Adapter (IOA) ports. IBM does not provide changes to the mode setting after #5887 is shipped.
Supported by AIX and Linux.
- Attributes provided: IOA configuration for Mode 1
- Attributes required: One YO cable (#3691 1.5M, #3692 3M, #3693 6M, #3694 15M) and one port on a #5901/#5278
- For 8205-E6D: (#9359)
- Minimum required: 0
- Maximum allowed: 14 (Initial order maximum: 14)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#9360) - Specify mode-1 1(2)5901/5278 for EXP24S #5887
Feature indicates that EXP24S SFF Gen2-bay Drawer (#5887) will be configured by IBM Manufacturing in Mode 1 (One group of 24 drive bays) with two individual PCIe 3G SAS controller (#5901 and/or #5278) utilizing two appropriate YO cables connecting to the 3G I/O Adapter (IOA) ports. IBM does not provide changes to the mode setting after #5887 is shipped.
Supported by AIX and Linux.
- Attributes provided: IOA configurations for Mode 1 with two (#5901 #5278)
- Attributes required: Two YO cables (#3691 1.5M, #3692 3M, #3693 6M, #3694 15M) and one port on each of two #5901/#5278s
- For 8205-E6D: (#9360)
- Minimum required: 0
- Maximum allowed: 19 (Initial order maximum: 19)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#9361) - Specify mode-2 1(2)5901/5278 for EXP24S #5887
Feature indicates that EXP24S SFF Gen2-bay Drawer (#5887) will be configured by IBM Manufacturing in Mode 2 (two sets of 12 drive bays) with two PCIe 3G SAS controllers (#5901 and/or #5278) utilizing two appropriate YO cables connecting to I/O Adapter (IOA) ports. IBM does not provide changes to the mode setting after #5887 is shipped.
Supported by AIX and Linux.
- Attributes provided: Designated IOA configurations for Mode 2
- Attributes required: Two YO cables (#3691 1.5M, #3692 3M, #3693 6M, #3694 15M) and one port on each of two #5901/#5278s
- For 8205-E6D: (#9361)
- Minimum required: 0
- Maximum allowed: 19 (Initial order maximum: 19)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#9365) - Specify mode-4 1(4)5901/5278 for EXP24S #5887
Feature indicates that EXP24S SFF Gen2-bay Drawer (#5887) will be configured by IBM Manufacturing in Mode 4 (four groups of 6 drive bays) with four PCIe 3G SAS controllers (#5901 and/or #5278) utilizing two appropriate dual X cables connecting to I/O Adapters (IOA) ports. IBM does not provide changes to the mode setting after #5887 is shipped.
Supported by AIX and Linux.
- Attributes provided: IOA configurations for Mode 4
- Attributes required: Two dual X cables (#3661 1.5M, #3662 3M, #3663 15M) and four #5901/ #5278s dedicated to the single #5887
- For 8205-E6D: (#9365)
- Minimum required: 0
- Maximum allowed: 19 (Initial order maximum: 19)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#9366) - Specify mode-2 1(4)5901/5278 for EXP24S #5887
Feature indicates that EXP24S SFF Gen2-bay Drawer (#5887) will be configured by IBM Manufacturing in Mode 2 (two sets of up to 12 drive bays) with four PCIe 3G SAS controllers (#5901 and/or #5278) utilizing two appropriate dual X cables connecting to I/O Adapters (IOA) ports. IBM does not provide changes to the mode setting after #5887 is shipped.
Supported by AIX and Linux.
- Attributes provided: IOA configurations for Mode 2
- Attributes required: Two dual X cables (#3661 1.5M, #3662 3M, #3663 15M) and four #5901/ #5278s dedicated to the single #5887
- For 8205-E6D: (#9366)
- Minimum required: 0
- Maximum allowed: 19 (Initial order maximum: 19)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#9367) - Specify mode-1 1(2)5903/5805 for EXP24S #5887
Feature indicates that EXP24S SFF Gen2-bay Drawer (#5887) will be configured by IBM Manufacturing in Mode 1 (One group of 1-24 drive bays) with a pair of PCIe 3G SAS RAID controller (either pair #5903 or 5805 or combination of both) utilizing two appropriate YO cable connecting to the 3G I/O Adapter (IOA) ports. This specify only impacts IBM's initial shipment of the EXP24S. IBM does not provide changes to the mode setting after #5887 is shipped.
- Attributes provided: IOA configurations for Mode 1
- Attributes required: Two YO cables (#3691 1.5M, #3692 3M, #3693 6M, #3694 15M) and one port on each of two #5903/#5805s
- For 8205-E6D: (#9367)
- Minimum required: 0
- Maximum allowed: 19 (Initial order maximum: 19)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 with i 6.1.1 machine code, or later
- IBM i 7.1, or later
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#9368) - Specify mode-2 1(4)5903/5805 for EXP24S #5887
Feature indicates that EXP24S SFF Gen2-bay Drawer (#5887) will be configured by IBM Manufacturing in Mode 2 (two sets of 12 drive bays) with two pair of PCIe 3G SAS RAID controller (either pair #5903 or 5805 or combination of both) utilizing two appropriate X cable connecting to the I/O Adapters (IOA). IBM does not provide changes to the mode setting after #5887 is shipped.
Supported by AIX and Linux.
- Attributes provided: IOA configurations for Mode 2
- Attributes required: Two dual X cables (#3661 1.5M, #3662 3M, #3663 15M) and four #5903/ #5805s dedicated to the single #5887"
- For 8205-E6D: (#9368)
- Minimum required: 0
- Maximum allowed: 19 (Initial order maximum: 19)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#9382) - Specify mode-1 1(1)5904/6/8 for EXP24S #5887
Feature indicates that EXP24S SFF Gen2-bay Drawer (#5887) will be configured by IBM Manufacturing in Mode 1 (One group of 24 drive bays) with one PCIe 3G SAS RAID controller (#5904, #5906 or #5908) utilizing one appropriate YO cable connecting to the 3G I/O Adapter (IOA). IBM does not provide changes to the mode setting after #5887 is shipped.
- Attributes provided: IOA configuration for Mode 1
- Attributes required: One YO cable (#3691 1.5M, #3692 3M, #3693 6M, #3694 15M) and one port on a #5904/#5906/#5908. Limit of 2 x #9382 per #5904/#5906/#5908
- For 8205-E6D: (#9382)
- Minimum required: 0
- Maximum allowed: 19 (Initial order maximum: 19)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 with i 6.1.1 machine code, or later
- IBM i 7.1, or later
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#9383) - Specify mode-1 1(2) 5904/6/8 for EXP24S #5887
Feature indicates that EXP24S SFF Gen2-bay Drawer (#5887) will be configured by IBM Manufacturing in Mode 1 (One group of 24 drive bays) with a pair of PCI-X 3G SAS RAID controller (#5904, #5906 or #5908) utilizing one appropriate YO cable connecting to the PCI-X I/ O Adapter (IOA) ports. IBM does not provide changes to the mode setting after #5887 is shipped.
- Attributes provided: IOA configuration for Mode 1
- Attributes required: Two YO cables (#3691 1.5M, #3692 3M, #3693 6M, #3694 15M) and one port on each of two #5904/#5906/#5908s. Limit of 2 x #9383 per #5904/ #5906/#5908 (paired adapters)
- For 8205-E6D: (#9383)
- Minimum required: 0
- Maximum allowed: 19 (Initial order maximum: 19)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 with i 6.1.1 machine code, or later
- IBM i 7.1, or later
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#9384) - Specify mode-1 & CEC SAS port for EXP24 #5887
Feature indicates that EXP24S SFF Gen2-bay Drawer (#5887) will be configured by IBM Manufacturing in Mode 1 (One group of 24 drive bays) with the internal 3G SAS port utilizing one appropriate length YI cable connecting to the 3G I/O Adapter (IOA) ports. IBM does not provide changes to the mode setting after #5887 is shipped.
- Attributes provided: Internal SAS port configuration for Mode 1
- Attributes required: One internal CEC SAS port and One YI cable (#3686 1.5m or #3687 3m)
- For 8205-E6D: (#9384)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#9385) - Specify mode-1 1(2) 5913 for EXP24S #5887
Specify feature 9385 (Specify mode-1 1(2 )5913 for EXP24S #5887) directs manufacturing to configure SFF drawer to Mode 1 (one group of 24 SFF bays) and two pair of PCIe2 1.8GB Cache RAID SAS Adapter Tri-port 6Gb (#5913). Select two YO cable #3450 1.5m, #3451 3m, #3452 6m, #3453 10m) and one AA cable (#5915 3m, #5916 6m, #5917 1.5m) and AIX, IBM i or Linux. Include one interconnecting 6Gb AA cable (3M #3681 or 6M #3682) between paired SAS adapters. IBM does not provide changes to the mode setting after #5887 is shipped.
- Attributes provided: Configuration #5887 Mode 1 with two #5913 adapters
- Attributes required: Two YO cables (#3450 1.5M, #3451 3M, #3452 6M, #3453 10M) and one port on each of two #5913s. If fewer than 3 ports on each of the #5913s are used, an AA cable (#5915 3M, #5916 6M, #5917 1.5M, #5918 0.6M) is required to connect the pair of #5913s
- For 8205-E6D: (#9385)
- Minimum required: 0
- Maximum allowed: 19 (Initial order maximum: 19)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 with i 6.1.1 machine code, or later
- IBM i 7.1, or later
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#9386) - Specify mode-2 1(4) 5913 for EXP24S #5887
Specify feature 9386 (Specify mode-2 1(4 )5913 for EXP24S #5887) directs manufacturing to configure SFF drawer to mode 2 (two sets of 12 SFF bays) and four PCIe2 1.8GB Cache RAID SAS Adapter Tri-port 6Gb. Select #5913 and two appropriate length X cable (#3454 3m, #3456 10m). Include AIX, or Linux and select two AA cables (3M #3681 or 6M #3682) between paired SAS adapters. IBM does not provide changes to the mode setting after #5887 is shipped.
Supported by AIX and Linux.
- Attributes provided: Configure #5887 in Mode 2
- Attributes required: Two dual X cables (#3454 3M, #3455 6M, #3456 10M), two AA cables (#5915 3M, #5916 6M, #5917 1.5M, #5918 0.6M) and one port on each of four #5913s dedicated to the single #5887.
- For 8205-E6D: (#9386)
- Minimum required: 0
- Maximum allowed: 19 (Initial order maximum: 19)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#9388) - Specify Mode-1 & EXP30 for 1 EXP24S #5887
This feature indicates that one EXP24S SFF Gen2-bay Drawer (#5887) will be configured by IBM Manufacturing in Mode 1 (one group of 24 drive bays) connected to an EXP30 Ultra SSD I/O Drawer (#EDR1) using two appropriate length EX cables. The #5887 will be controlled by the controllers internal to the EXP30. Up to two #5887s can be connected to one EXP30 (would be indicated by two #9388s), each with two EX cables connecting the #5887 T1 ports to the EXP30. One #5887 connects to both T1 ports on the EXP30. The other #5887 connects to both T2 ports on the EXP30 Only HDDs are supported in a #5887 when it is connected to an EXP30. IBM does not provide changes to the mode setting after #5887 is shipped.
- Attributes provided: Mode 1 configuration connected to EXP30
- Attributes required: One EXP30 and two EX cables
- For 8205-E6D: (#9388)
- Minimum required: 0
- Maximum allowed: 8 (Initial order maximum: 8)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 7.1, or later
Note: Maximum allowed is 2 with IBM i.
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note: Maximum allowed is 4 with IBM i.
(#9440) - New AIX License Core Counter
(No Longer Available as of November 30, 2015)
This feature is used to count the number of cores licensed to run AIX.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#9440)
- Minimum required: 0
- Maximum allowed: 16 (Initial order maximum: 16)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9441) - New IBM i License Core Counter
(No Longer Available as of November 30, 2015)
This feature is used to count the number of cores licensed to run IBM i.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#9441)
- Minimum required: 0
- Maximum allowed: 16 (Initial order maximum: 16)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9442) - New Red Hat License Core Counter
(No Longer Available as of November 30, 2015)
This feature is used to count the number of cores licensed to run Red Hat Linux.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#9442)
- Minimum required: 0
- Maximum allowed: 16 (Initial order maximum: 16)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9443) - New SUSE License Core Counter
(No Longer Available as of November 30, 2015)
This feature is used to count the number of cores licensed to run SUSE Linux.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#9443)
- Minimum required: 0
- Maximum allowed: 16 (Initial order maximum: 16)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9444) - Other AIX License Core Counter
(No Longer Available as of November 30, 2015)
This feature is used to count the number of existing AIX licenses transferred from another server.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#9444)
- Minimum required: 0
- Maximum allowed: 16 (Initial order maximum: 16)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9445) - Other Linux License Core Counter
(No Longer Available as of November 30, 2015)
This feature is used to count the number of existing Linux licenses transferred from another server.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#9445)
- Minimum required: 0
- Maximum allowed: 16 (Initial order maximum: 16)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9446) - 3rd Party Linux License Core Counter
(No Longer Available as of November 30, 2015)
This feature is used to count the number of cores licensed to run 3rd party Linux.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#9446)
- Minimum required: 0
- Maximum allowed: 16 (Initial order maximum: 16)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9447) - VIOS Core Counter
(No Longer Available as of November 30, 2015)
This feature is used to count the number of cores licensed to run VIOS (Virtual I/O Server).
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#9447)
- Minimum required: 0
- Maximum allowed: 16 (Initial order maximum: 16)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9449) - Other License Core Counter
(No Longer Available as of November 30, 2015)
This feature is used to count the number of other cores licensed.
- Attributes provided: None
- Attributes required: None
- For 8202-E4D: (#9449)
- Minimum required: 0
- Maximum allowed: 8 (Initial order maximum: 8)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9461) - Month Indicator
(No Longer Available as of November 30, 2015)
This month indicator is used to create a date stamp to enable CFR splitting and rejoining in order to circumvent the AAS maximum limitation of 30 systems entered on any one order. The quantity ordered for this feature is generated by eConfig.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#9461)
- Minimum required: 0
- Maximum allowed: 12 (Initial order maximum: 12)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9462) - Day Indicator
(No Longer Available as of November 30, 2015)
This day indicator is used to create a date stamp to enable CFR splitting and rejoining in order to circumvent the AAS maximum limitation of 30 systems entered on any one order. The quantity ordered for this feature is generated by eConfig.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#9462)
- Minimum required: 0
- Maximum allowed: 31 (Initial order maximum: 31)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9463) - Hour Indicator
(No Longer Available as of November 30, 2015)
This hour indicator is used to create a time stamp to enable CFR splitting and rejoining in order to circumvent the AAS maximum limitation of 30 systems entered on any one order. The quantity ordered for this feature is generated by eConfig.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#9463)
- Minimum required: 0
- Maximum allowed: 24 (Initial order maximum: 24)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9464) - Minute Indicator
(No Longer Available as of November 30, 2015)
This hour indicator is used to create a time stamp to enable CFR splitting and rejoining in order to circumvent the AAS maximum limitation of 30 systems entered on any one order. The quantity ordered for this feature is generated by eConfig.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#9464)
- Minimum required: 0
- Maximum allowed: 60 (Initial order maximum: 60)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9465) - Qty Indicator
(No Longer Available as of November 30, 2015)
This quantity indicator is used to specify the remaining, or N-1 quantity of CFR entities that need to be accumulated for rejoining. The quantity ordered for this feature is generated by eConfig. and is equal to N-1, where 'N' equals the total quantity of CFRs being rejoined.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#9465)
- Minimum required: 0
- Maximum allowed: 999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9466) - Countable Member Indicator
(No Longer Available as of November 30, 2015)
This administrative indicator used to identify each CFR associated with a date/time stamp that is eligible for splitting and rejoining. The quantity ordered for this feature is generated by eConfig.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#9466)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9700) - Language Group Specify - Dutch
(No Longer Available as of November 30, 2015)
Dutch language group for Nomenclature and Standard Publications.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#9700)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9703) - Language Group Specify - French
(No Longer Available as of November 30, 2015)
French language group for Nomenclature and Standard Publications.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#9703)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9704) - Language Group Specify - German
(No Longer Available as of November 30, 2015)
German language group for Nomenclature and Standard Publications.
- Attributes provided: Language specify
- Attributes required: None
- For 8205-E6D: (#9704)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9705) - Language Group Specify - Polish
(No Longer Available as of November 30, 2015)
Polish language group for Nomenclature and Standard Publications.
- Attributes provided: Language specify
- Attributes required: none
- For 8205-E6D: (#9705)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9706) - Language Group Specify - Norwegian
(No Longer Available as of November 30, 2015)
Norwegian language group for Nomenclature and Standard Publications.
- Attributes provided: Language specify
- Attributes required: None
- For 8205-E6D: (#9706)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9707) - Language Group Specify - Portuguese
(No Longer Available as of November 30, 2015)
Portuguese language group for Nomenclature and Standard Publications.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#9707)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9708) - Language Group Specify - Spanish
(No Longer Available as of November 30, 2015)
Spanish language group for Nomenclature and Standard Publications.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#9708)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9711) - Language Group Specify - Italian
(No Longer Available as of November 30, 2015)
Italian language group for Nomenclature and Standard Publications.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#9711)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9712) - Language Group Specify - Canadian French
(No Longer Available as of November 30, 2015)
Canadian French language group for Nomenclature and Standard Publications.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#9712)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9714) - Language Group Specify - Japanese
(No Longer Available as of November 30, 2015)
Japanese language group for Nomenclature and Standard Publications.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#9714)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9715) - Language Group Specify - Traditional Chinese (Taiwan)
(No Longer Available as of November 30, 2015)
Traditional Chinese language group for Nomenclature and Standard Publications.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#9715)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9716) - Language Group Specify - Korean
(No Longer Available as of November 30, 2015)
Korean language group for Nomenclature and Standard Publications.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#9716)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9718) - Language Group Specify - Turkish
(No Longer Available as of November 30, 2015)
Turkish language group for nomenclature and publications.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#9718)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9719) - Language Group Specify - Hungarian
(No Longer Available as of November 30, 2015)
Hungarian language group for Nomenclature and Standard Publications.
- Attributes provided: none
- Attributes required: none
- For 8205-E6D: (#9719)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9720) - Language Group Specify - Slovakian
(No Longer Available as of November 30, 2015)
Slovakian language group for Nomenclature and Standard Publications.
- Attributes provided: none
- Attributes required: none
- For 8205-E6D: (#9720)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9721) - Language Group Specify - Russian
(No Longer Available as of November 30, 2015)
Russian language group for nomenclature and standard publications.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#9721)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9722) - Language Group Specify - Simplified Chinese (PRC)
(No Longer Available as of November 30, 2015)
Simplified Chinese language group for nomenclature and standard publications.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#9722)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9724) - Language Group Specify - Czech
(No Longer Available as of November 30, 2015)
Czech language group for nomenclature and standard publications.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#9724)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9725) - Language Group Specify -- Romanian
(No Longer Available as of November 30, 2015)
Romanian language group for Nomenclature and Standard Publications.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#9725)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9726) - Language Group Specify - Croatian
(No Longer Available as of November 30, 2015)
Croatian language group for Nomenclature and Standard Publications.
- Attributes provided: Language specify
- Attributes required: None
- For 8205-E6D: (#9726)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9727) - Language Group Specify -- Slovenian
(No Longer Available as of November 30, 2015)
Slovenian language group for Nomenclature and Standard Publications.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#9727)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9728) - Language Group Specify - Brazilian Portuguese
(No Longer Available as of November 30, 2015)
Brazilian Portuguese language group for Nomenclature and Standard Publications.
- Attributes provided: Language specify
- Attributes required: None
- For 8205-E6D: (#9728)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#9729) - Language Group Specify - Thai
(No Longer Available as of November 30, 2015)
Thai language group for Nomenclature and Standard Publications.
- Attributes provided: Language specify
- Attributes required: None
- For 8205-E6D: (#9729)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#B0LG) - ServicePac Not Selected
(No Longer Available as of February 24, 2016)
ServicePac services not selected for this configuration
- For 8205-E6D: (#B0LG)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#B0LH) - Service Renewal Requested
(No Longer Available as of February 24, 2016)
Service renewal requested upon expiration
- For 8205-E6D: (#B0LH)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#B0UQ) - SP WSU 3Y 24x7 SD
ServicePac Warranty Service Upgrade 3 YR 24x7 Same Day ORT 6hrCL/ 4hrPD
- For 8205-E6D: (#B0UQ)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#B0VH) - SP HDR/MR POWER 3Y
ServicePac for Hard Drive or Media Retention for Power 3 years
- For 8205-E6D: (#B0VH)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EB2W) - EXP30 Carrier for 1.8-inch SSD
Carrier/tray to hold the #ES0J or #ES0K 387GB 1.8-inch Solid State Drive (SSD). One carrier/tray is used for each SSD that is to be installed in EXP30 Ultra SSD I/O Drawer (#5888 or #EDR1). Six #EB2W features are required for each #ESRJ or #ESRK six-pack feature.
This carrier/tray is not required for the #ES02 or #ES04 1.8-inch SSD.
- Attributes provided: carrier/tray
- Attributes required: One or more of any of the following features #ES0J, #ES0K, ESRJ, ESRK and available bays in EXP30 Ultra SSD I/O Drawer (#5888 or #EDR1)
- For 8205-E6D: (#EB2W)
- Minimum required: 0
- Maximum allowed: 120 (Initial order maximum: 120)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EB34) - IBM i 6.1.1 Native I/O Enablement
This feature enables IBM i 6.1.1 to natively support I/O on this POWER7+ server. Without this feature IBM i 6.1.1 partitions are virtual client-only partitions obtaining I/O through either an IBM i 7.1 partition or through VIOS.
When ordered IBM provides a VET code to this server which enables the native I/O support for one or more i 6.1.1 partitions running on one or more cores. Note the VET code is specific to one specific server (one specific serial number) and is not transferable to another server
- For 8205-E6D: (#EB34)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EB72) - IBM i 7.2 Indicator
This feature is used to indicate the correct level of code when IBM i is specified.
- Attributes provided: IBM i 7.2 Indicator
- Attributes required: IBM i operating system
- For 8205-E6D: (#EB72)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required:
- IBM i 7.2 or later supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: Does not apply
(#EB73) - IBM i 7.3 Indicator
This feature is used to indicate the correct level of code when IBM i is specified.
- Attributes provided: IBM i 7.3 Indicator
- Attributes required: IBM i operating system
- For 8205-E6D: (#EB73)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required:
- IBM i 7.3 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: Does not apply
(#EC01) - Rack Front Door (Black)
This feature provides a front door in flat black color with an IBM logo for the 7953-94X rack. A front door such as #EC01 is required on the 7953-94X. The door is the full width of the rack and the hinges and lockplate can be moved from side to side allowing the door to be opened on the left or on the right. IBM ships rack with the handle on the right and hinges on the left viewed facing the front of the rack. The door comes with a lock which is keyed the same as the rear door or side panels. Uniquely keyed locks can be obtained by the client directly from Southco, the vendor from whom IBM purchased the lock.
- Attributes provided: Front Door with lock
- Attributes required: None
- For 8202-E4D: (#EC01)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#EC02) - Rack Rear Door
This feature provides a rear door in flat black color for the 7953-94X rack. Either feature number EC02 or feature EC05 is required on the 7953-94X. The door is the full width of the rack and the hinges and lockplate can be moved from side to side allowing the door to be opened on the left or on the right. IBM ships rack with the handle on the right and hinges on the left viewed facing the rear of the rack. The front doors, rear doors and side panels come with a lock which is keyed the same as the front door or side panels. Uniquely keyed locks can be obtained by the client directly from Southco, the vendor from whom IBM purchased the lock.
- Attributes provided: Rear Door with lock
- Attributes required: None
- For 8202-E4D: (#EC02)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#EC03) - Rack Side Cover
This feature provides two side panels in black color for the 7953-94X rack. Each side panel can cover either the left or the right side of the rack. These side covers are optional but recommended for optimal airflow through a rack and for physical security. The front door, rear doors and side panels come with a lock which is keyed the same as the front door or side panels. Uniquely keyed locks can be obtained by the client directly from Southco, the vendor from whom IBM purchased the lock.
- Attributes provided: Left and Right side panels for 7953 rack.
- Attributes required: None
- For 8202-E4D: (#EC03)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#EC04) - Rack Suite Attachment Kit
This feature provides the attachment hardware to allow two IBM PureFlex System 42U Racks with or without side panels to be bolted together in a continuous suite. Order one EC04 feature for each 42U rack attached to the starting rack. For example, in a three-rack suite, order two EC04 features. When multiple racks are joined in this way without internal side panels, cables can be more easily run between racks without having to exit the continuous rack enclosure. With the side panels installed optimum thermal efficiencies are gained. If the optional rear door heat exchanger is chosen, side panels must remain on racks in the suite. Side panels should be used on the leftmost and rightmost racks of the suite.
- Attributes provided: Hardware and trim to attach two racks
- Attributes required: None
- For 8202-E4D: (#EC04)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#EC07) - Slim Rear Acoustic Door
Slim rear acoustic door for use on the 7014-T42 or server feature #0553 2. 0M racks. Depth of this acoustic door is only about 113 mm (4.45 inches).
Physically #EC07 and #EC08 are identical, but have two feature codes to assist IBM sales configurator logic. #EC07 designates a rear door and #EC08 designates a front door.
- Attributes provided: Rear Acoustic door
- Attributes required: None
- For 8205-E6D: (#EC07)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#EC08) - Slim Front Acoustic Door
Slim front acoustic door for use on the 7014-T42 or server feature #0553 2. 0M racks. Depth of this acoustic door is only about 113 mm (4.45 inches).
Physically #EC07 and #EC08 are identical, but have two feature codes to assist IBM sales configurator logic. #EC07 designates a rear door and #EC08 designates a front door.
- Attributes provided: Acoustic front door
- Attributes required: None
- For 8205-E6D: (#EC08)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#EC15) - Rear Door Heat Exchanger for 2.0 Meter Slim Rack
(No Longer Available as of March 31, 2018)
This feature indicates that the rear door heat exchanger (1164-95X) is ordered for the 7953-94Y rack. Either feature EC02 or feature EC05 is required on the 7953-94Y.
- Attributes provided: RDHX
- Attributes required: None
- For 8202-E4D: (#EC15)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#EC27) - PCIe2 LP 2-Port 10GbE RoCE SFP+ Adapter
(No Longer Available as of January 20, 2017)
As of 3/12/2013, this feature is not available in the following EMEA countries, Bahrain, Comoros, Djibouti, Iraq, Kuwait, Lebanon, Libya, Malaysia, Morocco, Oman, Pakistan, Qatar, Saudi Arabia, Somalia, Tunisia and United Arab Emirates which includes IBM Middle East - Dubai and Abu Dhabi and Yemen.
This PCIe Gen2 adapter provides two 10 Gb copper SFP+ ports and supports the IBTA RoCE standard. RoCE is Remote Direct Memory Access (RDMA) over Converged Ethernet. The adapter can support significantly greater bandwidth with low latency. It minimizes CPU overhead by more efficiently using memory access. This offloads the CPU from I/O networking tasks, improving performance and scalability.
Active Copper twinax cables up to 5 meter in length are supported such as provided by feature #EN01, #EN02 or #EN03. Note that SFP+ twinax copper is NOT AS/400 5250 twinax or CX4 or 10 GBASE-T. Active cables differ from passive cables.
Feature code #EC27 and #EC28 have identical electronics and function and CCIN (EC27), but have different tail stocks. #EC27 is low profile and #EC28 is full high.
- Attributes provided: Dual-port 10GbE Adapter with RoCE capability
- Attributes required: Available GEN2 PCIe Slot
- For 8205-E6D: (#EC27)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- AIX Version 7.1 with the 7100-02 Technology Level and Service Pack 2, or later
- AIX Version 6.1 with the 6100-08 Technology Level and Service Pack 2, or later
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EC28) - PCIe2 2-Port 10GbE RoCE SFP+ Adapter
(No Longer Available as of January 20, 2017)
As of 3/12/2013, this feature is not available in the following EMEA countries, Bahrain, Comoros, Djibouti, Iraq, Kuwait, Lebanon, Libya, Malaysia, Morocco, Oman, Pakistan, Qatar, Saudi Arabia, Somalia, Tunisia and United Arab Emirates which includes IBM Middle East - Dubai and Abu Dhabi and Yemen.
This PCIe Gen2 adapter provides two 10 Gb copper SFP+ ports and supports the IBTA RoCE standard. RoCE is Remote Direct Memory Access (RDMA) over Converged Ethernet. The adapter can support significantly greater bandwidth with low latency. It minimizes CPU overhead by more efficiently using memory access. This offloads the CPU from I/O networking tasks, improving performance and scalability.
Active Copper twinax cables up to 5 meter in length are supported such as provided by feature #EN01, #EN02 or #EN03. Note that SFP+ twinax copper is NOT AS/400 5250 twinax or CX4 or 10 GBASE-T. Active cables differ from passive cables.
Feature code #EC27 and #EC28 have identical electronics and function and CCIN (EC27), but have different tail stocks. #EC27 is low profile and #EC28 is full high.
- Attributes provided: Dual-port 10GbE Adapter with RoCE capability
- Attributes required: Available GEN2 PCIe Slot
- For 8205-E6D: (#EC28)
- Minimum required: 0
- Maximum allowed: 5 (Initial order maximum: 5)
- OS level required:
- AIX Version 7.1 with the 7100-02 Technology Level and Service Pack 2, or later
- AIX Version 6.1 with the 6100-08 Technology Level and Service Pack 2, or later
- IBM i support only through VIOS
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EC29) - PCIe2 LP 2-Port 10GbE RoCE SR Adapter
(No Longer Available as of February 23, 2017)
As of 3/12/2013, this feature is not available in the following EMEA countries, Bahrain, Comoros, Djibouti, Iraq, Kuwait, Lebanon, Libya, Malaysia, Morocco, Oman, Pakistan, Qatar, Saudi Arabia, Somalia, Tunisia and United Arab Emirates which includes IBM Middle East - Dubai and Abu Dhabi and Yemen.
This PCIe Gen2 adapter provides two 10 Gb SR optical ports and supports the IBTA RoCE standard. RoCE is Remote Direct Memory Access (RDMA) over Converged Ethernet. The adapter can support significantly greater bandwidth with low latency. It minimizes CPU overhead by more efficiently using memory access. This offloads the CPU from I/O networking tasks, improving performance and scalability.
The adapter includes a pre-installed Optical Transceiver in the adapter. LC connectors connect to standard 10Gb SR optical cabling and provide up to 300m cable length.
Feature code #EC29 and #EC30 have identical electronics and function and CCIN (EC29), but have different tail stocks. #EC29 is low profile and #EC30 is full high, Compared to Feature #EC27/EC28, the #EC29/EC30 have identical application capability and differ electronically only in that #EC27/ EC28 have a SFP+ copper interface and a different CCIN where the #EC29/EC30 have an SFP+ SR optical interface.
- Attributes provided: Dual-port 10GbE Adapter with RoCE capability
- Attributes required:
- Available GEN2 PCIe Slot
- Firmware Level 760 or greater
- For 8205-E6D: (#EC29)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EC2M) - PCIe3 LP 2-port 10GbE NIC&RoCE SR Adapter
(No Longer Available as of March 31, 2018)
This PCIe Gen3 adapter provides two 10 Gb SR optical fiber ports. The adapter supports both NIC and IBTA RoCE standards. RoCE is Remote Direct Memory Access (RDMA) over Converged Ethernet. Using RoCE, the adapter can support significantly greater bandwidth with low latency and minimize CPU overhead by more efficiently using memory access. This offloads the CPU from I/O networking tasks, improving performance and scalability.
The adapter includes two pre-installed Optical Transceivers in the adapter. LC connectors connect to standard 10Gb SR optical cabling and provide up to 300m cable length.
Feature code #EC2M and #EC2N have identical electronics and function and CCIN (57BE), but have different tail stocks. #EC2M is low profile and #EC2N is full high. Compared to EC37/EC38, the EC2M/ EC2N have identical application capability, but different cabling (optical fiber vs copper twinax). The EC2M/EC2N is based on the Mellanox ConnectX-3 Pro ASIC and is newer technology than previous features EC29/EC30.
LIMITATION: This adapter supports RoCE and NIC functions but not concurrently on same adapter.
Details for the ports include:
- AIX NIM and Linux Network Install are supported.
- IBTA RoCE v2 support.
- IEEE 802.3ae (10Gb Ethernet), IEEE 802.3ad (Link Aggregation 1 Failover), IEEE 802.3az (Energy Efficient Ethernet), IEEE 802.1Q/P (VLAN Tagging), IEEE 802.10au (Congestion Notification), IEEE 802.1Qbg, IEEE 802.3Qaz D0.2 (ETS), IEEE 802.1Qbb D1.0 (PFC), IEEE 1588v2 (PTP)
- Jumbo frame support up to 9.6KB
- VXLAN and NVGRE Overlay Network offload support
- TCP/UDP/IP stateless offload
- TCP checksum offload
- TCP segmentation offload
- UDP checksum offload
- MSI-X, MSI and support of legacy pin interrup
This feature is not available in the following countries: Abu Dhabi, Algeria, Bahrain, Comoros, Djibouti, Dubai, Iraq, Kuwait, Lebanon, Libya, Malaysia, Morocco, Oman, Pakistan, Qatar, Saudi Arabia, Somalia, Tunisia, United Arab Emirates, and Yemen.
- Attributes provided: 2-port 10Gb Ethernet Adapter with NIC and/or RoCE capability
- Attributes required: PCIe Gen3 or Gen2 slot
- For 8205-E6D: (#EC2M)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- AIX Version 6.1 with the 6100-09 Technology Level and service pack 5 and APAR IV68443 or later
- AIX Version 7.1 with the 7100-03 Technology Level and Service Pack 5 and APAR IV68444 or later
- AIX Version 7.1 with the 7100-02 Technology Level and Service Pack 7 or later
- AIX Version 6.1 with the 6100-08 Technology Level and service Pack 7 or later
- Red Hat Enterprise Linux 6.6, or later
- Red Hat Enterprise Linux 7.1, big endian, or later
- SUSE Linux Enterprise Server 11, Service Pack 4, or later
- IBM i supported only with VIOS. Only virtual ethernet NIC supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note: VIOS 2.23.51 or later, VIOS 2.2.2.7 or later; NIC capability only.
(#EC2N) - PCIe3 2-port 10GbE NIC&RoCE SR Adapter
(No Longer Available as of March 31, 2018)
This PCIe Gen3 adapter provides two 10 Gb SR optical fiber ports. The adapter supports both NIC and IBTA RoCE standards. RoCE is Remote Direct Memory Access (RDMA) over Converged Ethernet. Using RoCE, the adapter can support significantly greater bandwidth with low latency and minimize CPU overhead by more efficiently using memory access. This offloads the CPU from I/O networking tasks, improving performance and scalability.
The adapter includes two pre-installed Optical Transceivers in the adapter. LC connectors connect to standard 10Gb SR optical cabling and provide up to 300m cable length.
Feature code #EC2M and #EC2N have identical electronics and function and CCIN (57BE), but have different tail stocks. #EC2M is low profile and #EC2N is full high. Compared to EC37/EC38, the EC2M/ EC2N have identical application capability, but different cabling (optical fiber vs copper twinax). The EC2M/EC2N is based on the Mellanox ConnectX-3 Pro ASIC and is newer technology than previous features EC29/EC30.
LIMITATION: This adapter supports RoCE and NIC functions but not concurrently on same adapter.
Details for the ports include:
- AIX NIM and Linux Network Install are supported.
- IBTA RoCE v2 support.
- IEEE 802.3ae (10Gb Ethernet), IEEE 802.3ad (Link Aggregation 1 Failover), IEEE 802.3az (Energy Efficient Ethernet), IEEE 802.1Q/P (VLAN Tagging), IEEE 802.10au (Congestion Notification), IEEE 802.1Qbg, IEEE 802.3Qaz D0.2 (ETS), IEEE 802.1Qbb D1.0 (PFC), IEEE 1588v2 (PTP)
- Jumbo frame support up to 9.6KB
- VXLAN and NVGRE Overlay Network offload support
- TCP/UDP/IP stateless offload
- TCP checksum offload
- TCP segmentation offload
- UDP checksum offload
- MSI-X, MSI and support of legacy pin interrup
This feature is not available in the following countries: Abu Dhabi, Algeria, Bahrain, Comoros, Djibouti, Dubai, Iraq, Kuwait, Lebanon, Libya, Malaysia, Morocco, Oman, Pakistan, Qatar, Saudi Arabia, Somalia, Tunisia, United Arab Emirates, and Yemen.
- Attributes provided: 2-port 10Gb Ethernet Adapter with NIC and/or RoCE capability
- Attributes required: PCIe Gen3 or Gen2 slot
- For 8205-E6D: (#EC2N)
- Minimum required: 0
- Maximum allowed: 5 (Initial order maximum: 5)
- OS level required:
- AIX Version 6.1 with the 6100-09 Technology Level and service pack 5 and APAR IV68443 or later
- AIX Version 7.1 with the 7100-03 Technology Level and Service Pack 5 and APAR IV68444 or later
- AIX Version 7.1 with the 7100-02 Technology Level and Service Pack 7 or later
- AIX Version 6.1 with the 6100-08 Technology Level and service Pack 7 or later
- Red Hat Enterprise Linux 6.6, or later
- Red Hat Enterprise Linux 7.1, big endian, or later
- SUSE Linux Enterprise Server 11, Service Pack 4, or later
- IBM i supported only with VIOS. Only virtual ethernet NIC supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note: VIOS 2.23.51 or later, VIOS 2.2.2.7 or later; NIC capability only.
(#EC37) - PCIe3 LP 2-port 10GbE NIC&RoCE SFP+ Copper Adapter
(No Longer Available as of March 31, 2018)
This PCIe Gen3 adapter provides two 10 Gb SFP+ ports for copper twinax cabling/transceivers. The adapter supports both NIC and IBTA RoCE standards. RoCE is Remote Direct Memory Access (RDMA) over Converged Ethernet. Using RoCE, the adapter can support significantly greater bandwidth with low latency and minimize CPU overhead by more efficiently using memory access. This offloads the CPU from I/O networking tasks, improving performance and scalability.
Active Copper twinax cables up to 5 meter in length are supported such as provided by feature #EN01, #EN02 or #EN03. These cables also include copper transceivers. Active cables differ from passive cables.
Feature code #EC37 and #EC38 have identical electronics and function and CCIN (57BC), but have different tail stocks. #EC37 is low profile and #EC38 is full high. Compared to EC2M/EC2N, the EC37/ EC38 have identical application capability, but different cabling (optical fiber vs copper twinax). The EC37/EC38 is based on the Mellanox ConnectX-3 Pro ASIC and is newer technology than previous features EC27/EC28.
LIMITATION: This adapter supports RoCE and NIC functions but not concurrently on same adapter.
Details for the ports include:
- AIX NIM and Linux Network Install are supported.
- IBTA RoCE v2 support.
- IEEE 802.3ae (10Gb Ethernet), IEEE 802.3ad (Link Aggregation 1 Failover), IEEE 802.3az (Energy Efficient Ethernet), IEEE 802.1Q/P (VLAN Tagging), IEEE 802.10au (Congestion Notification), IEEE 802.1Qbg, IEEE 802.3Qaz D0.2 (ETS), IEEE 802.1Qbb D1.0 (PFC), IEEE 1588v2 (PTP)
- Jumbo frame support up to 9.6KB
- VXLAN and NVGRE Overlay Network offload support
- TCP/UDP/IP stateless offload
- TCP checksum offload
- TCP segmentation offload
- UDP checksum offload
- MSI-X, MSI and support of legacy pin interrup
This feature is not available in the following countries: Abu Dhabi, Algeria, Bahrain, Comoros, Djibouti, Dubai, Iraq, Kuwait, Lebanon, Libya, Malaysia, Morocco, Oman, Pakistan, Qatar, Saudi Arabia, Somalia, Tunisia, United Arab Emirates, and Yemen.
- Attributes provided: 2-port 10Gb Ethernet Adapter with NIC and/or RoCE capability
- Attributes required: PCIe Gen3 or Gen2 slot
- For 8205-E6D: (#EC37)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- AIX Version 6.1 with the 6100-09 Technology Level and service pack 5 and APAR IV68443 or later
- AIX Version 7.1 with the 7100-03 Technology Level and Service Pack 5 and APAR IV68444 or later
- AIX Version 7.1 with the 7100-02 Technology Level and Service Pack 7 or later
- AIX Version 6.1 with the 6100-08 Technology Level and service Pack 7 or later
- Red Hat Enterprise Linux 6.6, or later
- Red Hat Enterprise Linux 7.1, big endian, or later
- SUSE Linux Enterprise Server 11, Service Pack 4, or later
- IBM i supported only with VIOS. Only virtual ethernet NIC supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note: VIOS 2.23.51 or later, VIOS 2.2.2.7 or later; NIC capability only.
(#EC38) - PCIe3 2-port 10GbE NIC&RoCE SFP+ Copper Adapter
(No Longer Available as of March 31, 2018)
This PCIe Gen3 adapter provides two 10 Gb SFP+ ports for copper twinax cabling/transceivers. The adapter supports both NIC and IBTA RoCE standards. RoCE is Remote Direct Memory Access (RDMA) over Converged Ethernet. Using RoCE, the adapter can support significantly greater bandwidth with low latency and minimize CPU overhead by more efficiently using memory access. This offloads the CPU from I/O networking tasks, improving performance and scalability.
Active Copper twinax cables up to 5 meter in length are supported such as provided by feature #EN01, #EN02 or #EN03. These cables also include copper transceivers. Active cables differ from passive cables.
Feature code #EC37 and #EC38 have identical electronics and function and CCIN (57BC), but have different tail stocks. #EC37 is low profile and #EC38 is full high. Compared to EC2M/EC2N, the EC37/ EC38 have identical application capability, but different cabling (optical fiber vs copper twinax). The EC37/EC38 is based on the Mellanox ConnectX-3 Pro ASIC and is newer technology than previous features EC27/EC28.
LIMITATION: This adapter supports RoCE and NIC functions but not concurrently on same adapter.
Details for the ports include:
- AIX NIM and Linux Network Install are supported.
- IBTA RoCE v2 support.
- IEEE 802.3ae (10Gb Ethernet), IEEE 802.3ad (Link Aggregation 1 Failover), IEEE 802.3az (Energy Efficient Ethernet), IEEE 802.1Q/P (VLAN Tagging), IEEE 802.10au (Congestion Notification), IEEE 802.1Qbg, IEEE 802.3Qaz D0.2 (ETS), IEEE 802.1Qbb D1.0 (PFC), IEEE 1588v2 (PTP)
- Jumbo frame support up to 9.6KB
- VXLAN and NVGRE Overlay Network offload support
- TCP/UDP/IP stateless offload
- TCP checksum offload
- TCP segmentation offload
- UDP checksum offload
- MSI-X, MSI and support of legacy pin interrup
This feature is not available in the following countries: Abu Dhabi, Algeria, Bahrain, Comoros, Djibouti, Dubai, Iraq, Kuwait, Lebanon, Libya, Malaysia, Morocco, Oman, Pakistan, Qatar, Saudi Arabia, Somalia, Tunisia, United Arab Emirates, and Yemen.
- Attributes provided: 2-port 10Gb Ethernet Adapter with NIC and/or RoCE capability
- Attributes required: PCIe Gen3 or Gen2 slot
- For 8205-E6D: (#EC38)
- Minimum required: 0
- Maximum allowed: 5 (Initial order maximum: 5)
- OS level required:
- AIX Version 6.1 with the 6100-09 Technology Level and service pack 5 and APAR IV68443 or later
- AIX Version 7.1 with the 7100-03 Technology Level and Service Pack 5 and APAR IV68444 or later
- AIX Version 7.1 with the 7100-02 Technology Level and Service Pack 7 or later
- AIX Version 6.1 with the 6100-08 Technology Level and service Pack 7 or later
- Red Hat Enterprise Linux 6.6, or later
- Red Hat Enterprise Linux 7.1, big endian, or later
- SUSE Linux Enterprise Server 11, Service Pack 4, or later
- IBM i supported only with VIOS. Only virtual ethernet NIC supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note: VIOS 2.2.3.51 or later, VIOS 2.2.2.7 or later; VIOS supports NIC capability only.
(#EC41) - PCIe2 LP 3D Graphics Adapter x1
(No Longer Available as of December 29, 2017)
(No Longer Available as of March 28, 2017)
Note: Feature EC41 and EC42 are withdrawn only in the following European countries: Iceland, Liechtenstein, Norway, Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, United Kingdom. and Switzerland.
There are two identical 3D adapters EC41 with a low profile tail stock and EC42 with full high tail stock.
When using graphic adapter for Partition Firmware Console to select an install or boot device use #3632 display or rack mount 7316-TF4 display. Withdrawn display #3644 or withdrawn rack mount 7316-TF3 display may also be used.
Limit of one adapter per LPAR.
- Attributes provided: Graphics adapter with DMS-59 Dual DVI cable
- Attributes required: available PCIe2 slot
- For 8205-E6D: (#EC41)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- AIX - not supported
- IBM i - not supported
- Red Hat Enterprise Linux 7 or later
- Users should also update their systems with the latest Linux for POWER service and productivity tools from the IBM website
- http://www14.software.ibm.com/webapp/set2/sas/f/lopdi ags/home.html
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EC42) - PCIe2 3D Graphics Adapter x1
(No Longer Available as of December 29, 2017)
(No Longer Available as of March 28, 2017)
Note: Feature EC41 and EC42 are withdrawn only in the following European countries: Iceland, Liechtenstein, Norway, Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, United Kingdom. and Switzerland.
There are two identical 3D adapters EC41 with a low profile tail stock and EC42 with full high tail stock.
When using graphic adapter for Partition Firmware Console to select an install or boot device use #3632 display or rack mount 7316-TF4 display. Withdrawn display #3644 or withdrawn rack mount 7316-TF3 display may also be used.
Limit of one adapter per LPAR.
- Attributes provided: Graphics adapter with DMS-59 Dual DVI cable
- Attributes required: one available full height PCIe2 slot
- For 8205-E6D: (#EC42)
- Minimum required: 0
- Maximum allowed: 5 (Initial order maximum: 5)
- OS level required:
- AIX - not supported
- IBM i - not supported
- Red Hat Enterprise Linux 7 or later
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EC2G) - PCIe2 LP 2-port 10GbE SFN6122F Adapter
(No Longer Available as of January 20, 2017)
This PCIe Gen2 2-port 10Gb Ethernet adapter is manufactured by SolarFlare and supports their OpenOnload(R) application accelerator. The adapter is supported by Linux and can be used by user-provided applications written to leverage its interfaces.
This PCIe Gen2 adapter provides two 10 Gb copper SFP+ ports. Active Copper twinax cables up to 5 meter in length are supported such as provided by feature #EN01, #EN02 or #EN03. #EN01/EN02/EN03 cables include transceivers for SFP+ ports. Note that SFP+ twinax copper is NOT AS/400 5250 twinax or CX4 or 10 GBASE-T. Active cables differ from passive cables
#EC2G and #EC2J are electronically identical adapters, but #EC2G indicates a low profile tail stock and #EC2J indicates a full high tail stock.
See also #EC2H and #EC2K which is also manufactured by SolarFlare, but does not support the OpenOnload capability.
- Attributes provided: PCIe Gen2 adapter with 2 10Gb Ethernet ports which supports Solaflare OpenOnload
- Attributes required: Available low profile PCIe2 slot
- For 8205-E6D: (#EC2G)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- Aix - not supported
- IBM i - not supported
- Red Hat Enterprise Linux 6.4 for POWER, or later
- OpenOnload and performance optimized drivers are available for download directly from SolarFlare at the following location: http://support.solarflare.com/oem/ibmpower
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EC2H) - PCIe2 LP 2-port 10GbE SFN5162F Adapter
(No Longer Available as of July 31, 2014)
This PCIe Gen2 2-port 10Gb Ethernet adapter is manufactured by SolarFlare. The adapter is supported by Linux and can be used by user-provided applications written to leverage its interfaces.
This PCIe Gen2 adapter provides two 10 Gb copper SFP+ ports. Active Copper twinax cables up to 5 meter in length are supported such as provided by feature #EN01, #EN02 or #EN03. #EN01/EN02/EN03 cables include transceivers for SFP+ ports. Note that SFP+ twinax copper is NOT AS/400 5250 twinax or CX4 or 10 GBASE-T. Active cables differ from passive cables
#EC2H and #EC2K are electronically identical adapters, but #EC2H indicates a low profile tail stock and #EC2K indicates a full high tail stock.
See also #EC2G and #EC2J which is also manufactured by SolarFlare, but also supports their OpenOnload capability.
- Attributes provided: PCIe Gen2 adapter with 2 10Gb Ethernet ports which do not support Solaflare OpenOnload
- Attributes required: Available low profile PCIe2 slot
- For 8205-E6D: (#EC2H)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- Aix - not supported
- IBM i - not supported
- Red Hat Enterprise Linux 6.4 for POWER, or later
- Performance optimized drivers are available for download directly from SolarFlare at the following location: http://support.solarflare.com/oem/ibmpower
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EC2J) - PCIe2 2-port 10GbE SFN6122F Adapter
(No Longer Available as of January 20, 2017)
This PCIe Gen2 2-port 10Gb Ethernet adapter is manufactured by SolarFlare and supports their OpenOnload(R) application accelerator. The adapter is supported by Linux and can be used by user-provided applications written to leverage its interfaces.
This PCIe Gen2 adapter provides two 10 Gb copper SFP+ ports. Active Copper twinax cables up to 5 meter in length are supported such as provided by feature #EN01, #EN02 or #EN03. #EN01/EN02/EN03 cables include transceivers for SFP+ ports. Note that SFP+ twinax copper is NOT AS/400 5250 twinax or CX4 or 10 GBASE-T. Active cables differ from passive cables
#EC2G and #EC2J are electronically identical adapters, but #EC2G indicates a low profile tail stock and #EC2J indicates a full high tail stock.
See also #EC2H and #EC2K which is also manufactured by SolarFlare, but does not support the OpenOnload capability.
- Attributes provided: PCIe Gen2 adapter with 2 10Gb Ethernet ports which supports Solaflare OpenOnload
- Attributes required: Available full high PCIe2 slot
- For 8205-E6D: (#EC2J)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- Aix - not supported
- IBM i - not supported
- Red Hat Enterprise Linux 6.4 for POWER, or later
- OpenOnload and performance optimized drivers are available for download directly from SolarFlare at the following location: http://support.solarflare.com/oem/ibmpower
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EC2K) - PCIe2 2-port 10GbE SFN5162F Adapter
(No Longer Available as of July 31, 2014)
This PCIe Gen2 2-port 10Gb Ethernet adapter is manufactured by SolarFlare. The adapter is supported by Linux and can be used by user-provided applications written to leverage its interfaces.
This PCIe Gen2 adapter provides two 10 Gb copper SFP+ ports. Active Copper twinax cables up to 5 meter in length are supported such as provided by feature #EN01, #EN02 or #EN03. #EN01/EN02/EN03 cables include transceivers for SFP+ ports. Note that SFP+ twinax copper is NOT AS/400 5250 twinax or CX4 or 10 GBASE-T. Active cables differ from passive cables
#EC2H and #EC2K are electronically identical adapters, but #EC2H indicates a low profile tail stock and #EC2K indicates a full high tail stock.
See also #EC2G and #EC2J which is also manufactured by SolarFlare, but also supports their OpenOnload capability.
- Attributes provided: PCIe Gen2 adapter with 2 10Gb Ethernet ports which do not support Solaflare OpenOnload
- Attributes required: Available full high PCIe2 slot
- For 8205-E6D: (#EC2K)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- Aix - not supported
- IBM i - not supported
- Red Hat Enterprise Linux 6.4 for POWER, or later
- Performance optimized drivers are available for download directly from SolarFlare at the following location: http://support.solarflare.com/oem/ibmpower
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EC30) - PCIe2 2-Port 10GbE RoCE SR Adapter
(No Longer Available as of January 20, 2017)
This PCIe Gen2 adapter provides two 10 Gb SR optical ports and supports the IBTA RoCE standard. RoCE is Remote Direct Memory Access (RDMA) over Converged Ethernet. The adapter can support significantly greater bandwidth with low latency. It minimizes CPU overhead by more efficiently using memory access. This offloads the CPU from I/O networking tasks, improving performance and scalability.
The adapter includes a pre-installed Optical Transceiver in the adapter. LC connectors connect to standard 10Gb SR optical cabling and provide up to 300m cable length
Feature code #EC29 and #EC30 have identical electronics and function and CCIN (EC29), but have different tail stocks. #EC29 is low profile and #EC30 is full high, Compared to Feature #EC27/EC28, the #EC29/EC30 have identical application capability and differ electronically only in that #EC27/ EC28 have a SFP+ copper interface and a different CCIN where the #EC29/EC30 have an SFP+ SR optical interface.
- Attributes provided: Dual-port 10GbE Adapter with RoCE capability
- Attributes required:
- Available GEN2 PCIe Slot
- Firmware Level 760 or greater
- For 8205-E6D: (#EC30)
- Minimum required: 0
- Maximum allowed: 5 (Initial order maximum: 5)
- OS level required:
- AIX Version 7.1 with the 7100-02 Technology Level and Service Pack 2, or later
- AIX Version 6.1 with the 6100-08 Technology Level and Service Pack 2, or later
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Limitations:
- AIX NIM and Linux Network Install are not supported
- This adapter supports RoCE and NIC functions but not concurrently on same adapters.
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
As of 3/12/2013, this feature is not available in the following EMEA countries, Bahrain, Comoros, Djibouti, Iraq, Kuwait, Lebanon, Libya, Malaysia, Morocco, Oman, Pakistan, Qatar, Saudi Arabia, Somalia, Tunisia and United Arab Emirates which includes IBM Middle East - Dubai and Abu Dhabi and Yemen.
(#ECB0) - 0.6m (2.0-ft), Blue CAT5 Ethernet Cable
This 0.6M Cat5e cables is used with ports/transceivers that have RJ-45 connectors.
- Attributes provided: 0.6m Cat5e Ethernet Cable
- Attributes required: RJ45 ports/transceivers.
- For 8205-E6D: (#ECB0)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ECB2) - 1.5m (4.9-ft), Blue CAT5 Ethernet Cable
This cable connects the Flex System Enterprise Chassis to managed PDUs and the IBM Storwize V7000 Disk System.
- Attributes provided: 1.5m Cat5 Ethernet Cable
- Attributes required: RJ45 ports/transceivers.
- For 8205-E6D: (#ECB2)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ECBB) SAS AT Cable 0.6m - HD Narrow 6Gb Adapter to 12X Enclosure (AT)
This 0.6 meter SAS cable connects a PCIe2 or PCIe3 SAS adapter to a SAS port on a 12X-attached #5802 or #5803 I/O drawer. This AT cable has two connectors, one Mini-SAS HD (High Density) Narrow connector and one Mini SAS connector. The Mini-SAS HD Narrow connector attaches to a SAS adapter such as the #EJ0J or #5913 SAS Adapters. The cable can support up to 6Gb throughput.
This cable is almost identical to the #3689 SAS AT cable, except #ECBB connector for the SAS adapter is more narrow allowing it to fit onto the newer PCIe3 SAS adapters.
- Attributes provided: Connection between PCIe3 SAS adapter with Mini-SAS HD Narrow connectors and a SAS I/O drawer with Mini-SAS connectors or between PCIe2 SAS adapter with Mini-SAS HD connectors and a SAS I/O drawer with Mini-SAS connectors.
- Attributes required: available connectors on SAS controller and SAS I/O drawer. If a pair of adapters, at least one adapter must be in that same I/O drawer. If single adapter, that adapter must be in that same I/O drawer.
- For 8205-E6D: (#ECBB)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ECBJ) - SAS X Cable 3m - HD Narrow 6Gb 2-Adapters to Enclosure
This 3 meter SAS cable connects two PCIe2 SAS adapters or two PCIe3 SAS adapters to a SAS I/O enclosure. This X cable has four connectors, two Mini-SAS HD (High Density) Narrow connector and two Mini SAS connectors. The Mini-SAS HD Narrow connectors attach to two SAS adapters such as two #EJ0J or two #EJ0L or two #5913. Both Mini SAS connectors attach to the same I/O drawer (enclosure) such as a #5886 EXP12S or #5887 EXP24S SAS I/O drawer. This cable can support up to 6Gb throughput.
Multiple cable length feature codes are available. Choose the cable length that best matches the distance between the adapter and the I/O drawer. See SAS cabling documentation for the length of each leg of the cable. The SAS adapters can be in the same or in different PCIe I/O drawers. Or one adapter can be in a supported Power System CEC and the other adapter can be in a PCIe I/O drawer. Or both adapters can be in a supported Power System CEC.
This cable is almost identical to the #3454 3m SAS X cable, except #ECBJ connectors for the SAS adapters are more narrow allowing it to fit onto the newer PCIe3 SAS adapters.
- Attributes provided: Connection between PCIe3 SAS adapter with Mini-SAS HD Narrow connectors and a SAS I/O drawer with Mini-SAS connectors or between PCIe2 SAS adapter with Mini-SAS HD connectors and a SAS I/O drawer with Mini-SAS connectors.
- Attributes required: available connectors on SAS controllers and SAS I/O drawer
- For 8205-E6D: (#ECBJ)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ECBK) - SAS X Cable 6m - HD Narrow 6Gb 2-Adapters to Enclosure
This 3 meter SAS cable connects two PCIe2 SAS adapters or two PCIe3 SAS adapters to a SAS I/O enclosure. This X cable has four connectors, two Mini-SAS HD (High Density) Narrow connector and two Mini SAS connectors. The Mini-SAS HD Narrow connectors attach to two SAS adapters such as two #EJ0J or two #EJ0L or two #5913. Both Mini SAS connectors attach to the same I/O drawer (enclosure) such as a #5886 EXP12S or #5887 EXP24S SAS I/O drawer. This cable can support up to 6Gb throughput.
Multiple cable length feature codes are available. Choose the cable length that best matches the distance between the adapter and the I/O drawer. See SAS cabling documentation for the length of each leg of the cable. The SAS adapters can be in the same or in different PCIe I/O drawers. Or one adapter can be in a supported Power System CEC and the other adapter can be in a PCIe I/O drawer. Or both adapters can be in a supported Power System CEC.
This cable is almost identical to the #3454 3m SAS X cable, except #ECBJ connectors for the SAS adapters are more narrow allowing it to fit onto the newer PCIe3 SAS adapters.
This 6 meter SAS cable connects two SAS adapters to a SAS I/O enclosure. This X cable has four connectors, two Mini-SAS HD (High Density) connector and two Mini SAS connectors. The Mini-SAS HD connectors attaches to two SAS adapters such as the #5913 1.8GB RAID SAS Adapter. Both Mini SAS connectors attach to the same I/O drawer (enclosure) such as a #5886 EXP12S or #5887 EXP24S SAS I/O drawer. This cable can support up to 6Gb throughput.
Multiple cable length feature codes are available. Choose the cable length that best matches the distance between the adapter and the I/O drawer. See SAS cabling documentation for the length of each leg of the cable. The SAS adapters can be in the same or in different PCIe I/O drawers. Or one adapters can be in a supported Power System CEC and the other adapter can be in a PCIe I/O drawer. Or both adapters can be in a supported Power System CEC.
- Limitation: When this cable is ordered with a system in a rack specifying IBM Plant integration, IBM Manufacturing will ship SAS cables longer than 3 meters in a separate box and not attempt to place the cable in the rack.
- Attributes provided: Connection between PCIe3 SAS adapter with Mini-SAS HD Narrow connectors and a SAS I/O drawer with Mini-SAS connectors or between PCIe2 SAS adapter with Mini-SAS HD connectors and a SAS I/O drawer with Mini-SAS connectors.
- Attributes required: available connectors on SAS controllers and SAS I/O drawer
- For 8205-E6D: (#ECBK)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ECBL) - SAS X Cable 10m - HD Narrow 6Gb 2-Adapters to Enclosure
This 3 meter SAS cable connects two PCIe2 SAS adapters or two PCIe3 SAS adapters to a SAS I/O enclosure. This X cable has four connectors, two Mini-SAS HD (High Density) Narrow connector and two Mini SAS connectors. The Mini-SAS HD Narrow connectors attach to two SAS adapters such as two #EJ0J or two #EJ0L or two #5913. Both Mini SAS connectors attach to the same I/O drawer (enclosure) such as a #5886 EXP12S or #5887 EXP24S SAS I/O drawer. This cable can support up to 6Gb throughput.
Multiple cable length feature codes are available. Choose the cable length that best matches the distance between the adapter and the I/O drawer. See SAS cabling documentation for the length of each leg of the cable. The SAS adapters can be in the same or in different PCIe I/O drawers. Or one adapter can be in a supported Power System CEC and the other adapter can be in a PCIe I/O drawer. Or both adapters can be in a supported Power System CEC.
This cable is almost identical to the #3454 3m SAS X cable, except #ECBJ connectors for the SAS adapters are more narrow allowing it to fit onto the newer PCIe3 SAS adapters.
- Limitation: When this cable is ordered with a system in a rack specifying IBM Plant integration, IBM Manufacturing will ship SAS cables longer than 3 meters in a separate box and not attempt to place the cable in the rack.
- Attributes provided: Connection between PCIe3 SAS adapter with Mini-SAS HD Narrow connectors and a SAS I/O drawer with Mini-SAS connectors or between PCIe2 SAS adapter with Mini-SAS HD connectors and a SAS I/O drawer with Mini-SAS connectors.
- Attributes required: available connectors on SAS controllers and SAS I/O drawer
- For 8205-E6D: (#ECBL)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ECBM) - SAS X Cable 15m - HD Narrow 3Gb 2-Adapters to Enclosure
This 15 meter SAS cable connects two PCIe2 SAS adapters or two PCIe3 SAS adapters to a SAS I/O enclosure. This X cable has four connectors, two Mini-SAS HD (High Density) Narrow connector and two Mini SAS connectors. The Mini-SAS HD Narrow connectors attach to two SAS adapters such as two #EJ0J or two #EJ0L or two #5913. Both Mini SAS connectors attach to the same I/O drawer (enclosure) such as a #5886 EXP12S or #5887 EXP24S SAS I/O drawer. This cable can support up to 6Gb throughput.
Multiple cable length feature codes are available. Choose the cable length that best matches the distance between the adapter and the I/O drawer. See SAS cabling documentation for the length of each leg of the cable. The SAS adapters can be in the same or in different PCIe I/O drawers. Or one adapter can be in a supported Power System CEC and the other adapter can be in a PCIe I/O drawer. Or both adapters can be in a supported Power System CEC.
This cable is almost identical to the #3458 15m SAS X cable, except #ECBM connectors for the SAS adapters are more narrow allowing it to fit onto the newer PCIe3 SAS adapters.
- Limitation: When this cable is ordered with a system in a rack specifying IBM Plant integration, IBM Manufacturing will ship SAS cables longer than 3 meters in a separate box and not attempt to place the cable in the rack.
- Attributes provided: Connection between PCIe3 SAS adapter with Mini-SAS HD Narrow connectors and a SAS I/O drawer with Mini-SAS connectors or between PCIe2 SAS adapter with Mini-SAS HD connectors and a SAS I/O drawer with Mini-SAS connectors.
- Attributes required: available connectors on SAS controllers and SAS I/O drawer
- For 8205-E6D: (#ECBM)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ECBT) - SAS YO Cable 1.5m - HD Narrow 6Gb Adapter to Enclosure
This 1.5 meter SAS cable connects a PCIe2 SAS adapter or a PCIe3 SAS adapter to a SAS I/O enclosure. This YO cable has three connectors, one Mini-SAS HD (High Density) Narrow connector and two Mini SAS connectors. The Mini-SAS HD Narrow connector attaches to a SAS adapter such as the #EJ0J or #EJ0L or #5913. Both Mini SAS connectors attach to the same I/O drawer (enclosure) such as a #5886 EXP12S or #5887 EXP24S SAS I/O drawer. This cable can support up to 6Gb throughput.
Multiple cable length feature codes are available. Choose the cable length that best matches the distance between the adapter and the I/O drawer. See SAS cabling documentation for the length of each leg of the cable.
This cable is almost identical to the #3450 1.5m SAS YO cable, except the #ECBT connector for the SAS adapters is more narrow allowing it to fit onto the newer PCIe3 SAS adapters.
- Attributes provided: Connection between PCIe3 SAS adapter with Mini-SAS HD Narrow connectors and a SAS I/O drawer with Mini-SAS connectors or between PCIe2 SAS adapter with Mini-SAS HD connectors and a SAS I/O drawer with Mini-SAS connectors.
- Attributes required: available connectors on SAS controller and SAS I/O drawer
- For 8205-E6D: (#ECBT)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ECBU) - SAS YO Cable 3m - HD Narrow 6Gb Adapter to Enclosure
This 3 meter SAS cable connects a PCIe2 SAS adapter or a PCIe3 SAS adapter to a SAS I/O enclosure. This YO cable has three connectors, one Mini-SAS HD (High Density) Narrow connector and two Mini SAS connectors. The Mini-SAS HD Narrow connector attaches to a SAS adapter such as the #EJ0J or #EJ0L or #5913. Both Mini SAS connectors attach to the same I/O drawer (enclosure) such as a #5886 EXP12S or #5887 EXP24S SAS I/O drawer. This cable can support up to 6Gb throughput.
Multiple cable length feature codes are available. Choose the cable length that best matches the distance between the adapter and the I/O drawer. See SAS cabling documentation for the length of each leg of the cable.
This cable is almost identical to the #3451 3m SAS YO cable, except the #ECBU connector for the SAS adapters is more narrow allowing it to fit onto the newer PCIe3 SAS adapters.
- Attributes provided: Connection between PCIe3 SAS adapter with Mini-SAS HD Narrow connectors and a SAS I/O drawer with Mini-SAS connectors or between PCIe2 SAS adapter with Mini-SAS HD connectors and a SAS I/O drawer with Mini-SAS connectors.
- Attributes required: available connectors on SAS controller and SAS I/O drawer
- For 8205-E6D: (#ECBU)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ECBV) - SAS YO Cable 6m - HD Narrow 6Gb Adapter to Enclosure
This 6 meter SAS cable connects a PCIe2 SAS adapter or a PCIe3 SAS adapter to a SAS I/O enclosure. This YO cable has three connectors, one Mini-SAS HD (High Density) Narrow connector and two Mini SAS connectors. The Mini-SAS HD Narrow connector attaches to a SAS adapter such as the #EJ0J or #EJ0L or #5913. Both Mini SAS connectors attach to the same I/O drawer (enclosure) such as a #5886 EXP12S or #5887 EXP24S SAS I/O drawer. This cable can support up to 6Gb throughput.
Multiple cable length feature codes are available. Choose the cable length that best matches the distance between the adapter and the I/O drawer. See SAS cabling documentation for the length of each leg of the cable.
This cable is almost identical to the #3452 6m SAS YO cable, except the #ECBV connector for the SAS adapters is more narrow allowing it to fit onto the newer PCIe3 SAS adapters.
- Limitation: When this cable is ordered with a system in a rack specifying IBM Plant integration, IBM Manufacturing will ship SAS cables longer than 3 meters in a separate box and not attempt to place the cable in the rack.
- Attributes provided: Connection between PCIe3 SAS adapter with Mini-SAS HD Narrow connectors and a SAS I/O drawer with Mini-SAS connectors or between PCIe2 SAS adapter with Mini-SAS HD connectors and a SAS I/O drawer with Mini-SAS connectors.
- Attributes required: available connectors on SAS controller and SAS I/O drawer
- For 8205-E6D: (#ECBV)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ECBW) - SAS YO Cable 10m - HD Narrow 6Gb Adapter to Enclosure
This 10 meter SAS cable connects a PCIe2 SAS adapter or a PCIe3 SAS adapter to a SAS I/O enclosure. This YO cable has three connectors, one Mini-SAS HD (High Density) Narrow connector and two Mini SAS connectors. The Mini-SAS HD Narrow connector attaches to a SAS adapter such as the #EJ0J or #EJ0L or #5913. Both Mini SAS connectors attach to the same I/O drawer (enclosure) such as a #5886 EXP12S or #5887 EXP24S SAS I/O drawer. This cable can support up to 6Gb throughput.
Multiple cable length feature codes are available. Choose the cable length that best matches the distance between the adapter and the I/O drawer. See SAS cabling documentation for the length of each leg of the cable.
This cable is almost identical to the #3453 10m SAS YO cable, except the #ECBW connector for the SAS adapters is more narrow allowing it to fit onto the newer PCIe3 SAS adapters.
- Limitation: When this cable is ordered with a system in a rack specifying IBM Plant integration, IBM Manufacturing will ship SAS cables longer than 3 meters in a separate box and not attempt to place the cable in the rack.
- Attributes provided: Connection between PCIe3 SAS adapter with Mini-SAS HD Narrow connectors and a SAS I/O drawer with Mini-SAS connectors or between PCIe2 SAS adapter with Mini-SAS HD connectors and a SAS I/O drawer with Mini-SAS connectors.
- Attributes required: available connectors on SAS controller and SAS I/O drawer
- For 8205-E6D: (#ECBW)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ECBX) - SAS YO Cable 15m - HD Narrow 3Gb Adapter to Enclosure
This 15 meter SAS cable connects a PCIe2 SAS adapter or a PCIe3 SAS adapter to a SAS I/O enclosure. This YO cable has three connectors, one Mini-SAS HD (High Density) Narrow connector and two Mini SAS connectors. The Mini-SAS HD Narrow connector attaches to a SAS adapter such as the #EJ0J or #EJ0L or #5913. Both Mini SAS connectors attach to the same I/O drawer (enclosure) such as a #5887 EXP24S SAS I/O drawer. This cable can support up to 3Gb throughput.
Multiple cable length feature codes are available. Choose the cable length that best matches the distance between the adapter and the I/O drawer. See SAS cabling documentation for the length of each leg of the cable.
This cable is almost identical to the #3457 15m SAS YO cable, except the #ECBX connector for the SAS adapters is more narrow allowing it to fit onto the newer PCIe3 SAS adapters.
- Limitation:
- Does not support 6Gb throughput.
- When this cable is ordered with a system in a rack specifying IBM Plant integration, IBM Manufacturing will ship SAS cables longer than 3 meters in a separate box and not attempt to place the cable in the rack.
- Attributes provided: Connection between PCIe3 SAS adapter with Mini-SAS HD Narrow connectors and a SAS I/O drawer with Mini-SAS connectors or between PCIe2 SAS adapter with Mini-SAS HD connectors and a SAS I/O drawer with Mini-SAS connectors.
- Attributes required: available connectors on SAS controller and SAS I/O drawer
- For 8205-E6D: (#ECBX)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ECBY) - SAS AE1 Cable 4m - HD Narrow 6Gb Adapter to Enclosure
This 4 meter SAS cable connects a PCIe3 SAS adapter to a SAS tape drive. The tape drive is probably in an I/O enclosure such as a bridge box or 1U media enclosure or tape library. This AE cable has two connectors, one Mini-SAS HD (High Density) Narrow connector and one Mini-SAS connectors. The Mini-SAS HD Narrow connector attaches to a SAS adapter such as the #EJ0X. The Mini-SAS connector attaches to a SAS tape drive enclosure. This cable can support up to 6Gb throughput.
Use #ECBY when ordering the cable as a feature code on a Power System. Alternatively the same cable can be ordered using feature code #5507 of the IBM tape enclosure.
- Attributes provided: connection between PCIe3 SAS adapter with Mini-SAS HD Narrow connectors and a SAS tape drive with Mini-SAS connectors
- Attributes Required: Available connectors on SAS controller such as #EJ0X, #EJ10 or #EJ11 and an available SAS tape drive.
- For 8205-E6D: (#ECBY)
- Minimum required:
- Maximum allowed: (Initial order maximum: )
- OS level required:
- Initial Order/MES/Both/Supported: Both
- CSU:
- Return parts MES:
(#ECBZ) - SAS YE1 Cable 3m - HD Narrow 6Gb Adapter to Enclosure
This 3 meter SAS cable connects a PCIe3 SAS adapter to one or two SAS tape drives. The tape drive(s) is probably in an I/O enclosure such as a bridge box or 1U media enclosure or tape library. This YO cable has three connectors, one Mini-SAS HD (High Density) Narrow connector and two Mini-SAS connectors. The Mini-SAS HD Narrow connector attaches to a SAS adapter such as the #EJ0X. Each Mini-SAS connector attaches to a different SAS tape drive enclosure. This cable can support up to 6Gb throughput.
Use #ECBZ when ordering the cable as a feature code on a Power System. Alternatively the same cable can be ordered using feature code #5509 of the IBM tape enclosure.
- Attributes provided: connection between PCIe3 SAS adapter with Mini-SAS HD Narrow connectors and one or two SAS tape drives with Mini-SAS connectors.
- Attributes required: Available connectors on SAS controller such as #EJ0X, #EJ10 or #EJ11 for use with an available SAS tape drive.
- For 8205-E6D: (#ECBZ)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ECC0) - SAS AA Cable 0.6m - HD Narrow 6Gb Adapter to Adapter
This 0.6m SAS cable connects a pair of PCIe SAS adapters with write cache to each other. The pair can be two PCIe3 SAS adapters or can be two PCIe2 SAS adapters. This AA cable has two Mini-SAS HD (High Density) Narrow connectors which connect the top connectors of the two PCIe adapters providing a high performance path of all the dual controller communication including mirroring the write cache and status awareness of each card. This cable can support up to 6Gb throughput.
Two AA cables are always required between a pair of PCIe3 SAS adapters with write cache such as #EJ0L unless six (three pair) of ports or unless eight (four pair) are used to attach I/O drawers. One AA cable is always required between a pair of PCIe2 SAS adapters with write cache (pair of #5913 or a pair of #ESA3) unless all six (three pair) of ports are used to attach I/O drawers. If an AA cable fails or is disconnected, then the information it was carrying is then sent over the cables attached to the I/O drawers, sharing their bandwidth.
Multiple cable length feature codes are available. Choose the cable length that best matches the distance between the two adapters. p.This cable is almost identical to the #5918 0.6m SAS AA cable, except #ECC0 connectors for the SAS adapters are more narrow allowing it to fit onto the newer PCIe3 SAS adapters.
- Attributes provided: high speed connection between two PCIe2 or two PCIe3 SAS adapters with write cache
- Attributes required: available top connectors on pair of PCIe2 or PCIe3 SAS adapters with write cache
- For 8205-E6D: (#ECC0)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ECC2) - SAS AA Cable 1.5m - HD Narrow 6Gb Adapter to Adapter
This 1.5m SAS cable connects a pair of PCIe SAS adapters with write cache to each other. The pair can be two PCIe3 SAS adapters or can be two PCIe2 SAS adapters. This AA cable has two Mini-SAS HD (High Density) Narrow connectors which connect the top connectors of the two PCIe adapters providing a high performance path of all the dual controller communication including mirroring the write cache and status awareness of each card. This cable can support up to 6Gb throughput.
Two AA cables are always required between a pair of PCIe3 SAS adapters with write cache such as #EJ0L unless six (three pair) of ports or unless eight (four pair) are used to attach I/O drawers. One AA cable is always required between a pair of PCIe2 SAS adapters with write cache (pair of #5913 or a pair of #ESA3) unless all six (three pair) of ports are used to attach I/O drawers. If an AA cable fails or is disconnected, then the information it was carrying is then sent over the cables attached to the I/O drawers, sharing their bandwidth.
Multiple cable length feature codes are available. Choose the cable length that best matches the distance between the two adapters. p.This cable is almost identical to the #5917 1.5m SAS AA cable, except #ECC2 connectors for the SAS adapters are more narrow allowing it to fit onto the newer PCIe3 SAS adapters.
- Attributes provided: high speed connection between two PCIe2 or two PCIe3 SAS adapters with write cache
- Attributes required: available top connectors on pair of PCIe2 or PCIe3 SAS adapters with write cache
- For 8205-E6D: (#ECC2)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ECC3) - SAS AA Cable 3m - HD Narrow 6Gb Adapter to Adapter
This 3m SAS cable connects a pair of PCIe SAS adapters with write cache to each other. The pair can be two PCIe3 SAS adapters or can be two PCIe2 SAS adapters. This AA cable has two Mini-SAS HD (High Density) Narrow connectors which connect the top connectors of the two PCIe adapters providing a high performance path of all the dual controller communication including mirroring the write cache and status awareness of each card. This cable can support up to 6Gb throughput.
Two AA cables are always required between a pair of PCIe3 SAS adapters with write cache such as #EJ0L unless six (three pair) of ports or unless eight (four pair) are used to attach I/O drawers. One AA cable is always required between a pair of PCIe2 SAS adapters with write cache (pair of #5913 or a pair of #ESA3) unless all six (three pair) of ports are used to attach I/O drawers. If an AA cable fails or is disconnected, then the information it was carrying is then sent over the cables attached to the I/O drawers, sharing their bandwidth.
Multiple cable length feature codes are available. Choose the cable length that best matches the distance between the two adapters. p.This cable is almost identical to the #5915 3m SAS AA cable, except #ECC3 connectors for the SAS adapters are more narrow allowing it to fit onto the newer PCIe3 SAS adapters.
- Attributes provided: high speed connection between two PCIe2 or two PCIe3 SAS adapters with write cache
- Attributes required: available top connectors on pair of PCIe2 or PCIe3 SAS adapters with write cache
- For 8205-E6D: (#ECC3)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ECC4) - SAS AA Cable 6m - HD Narrow 6Gb Adapter to Adapter
This 6m SAS cable connects a pair of PCIe SAS adapters with write cache to each other. The pair can be two PCIe3 SAS adapters or can be two PCIe2 SAS adapters. This AA cable has two Mini-SAS HD (High Density) Narrow connectors which connect the top connectors of the two PCIe adapters providing a high performance path of all the dual controller communication including mirroring the write cache and status awareness of each card. This cable can support up to 6Gb throughput.
Two AA cables are always required between a pair of PCIe3 SAS adapters with write cache such as #EJ0L unless six (three pair) of ports or unless eight (four pair) are used to attach I/O drawers. One AA cable is always required between a pair of PCIe2 SAS adapters with write cache (pair of #5913 or a pair of #ESA3) unless all six (three pair) of ports are used to attach I/O drawers. If an AA cable fails or is disconnected, then the information it was carrying is then sent over the cables attached to the I/O drawers, sharing their bandwidth.
Multiple cable length feature codes are available. Choose the cable length that best matches the distance between the two adapters. p.This cable is almost identical to the #5916 6m SAS AA cable, except #ECC4 connectors for the SAS adapters are more narrow allowing it to fit onto the newer PCIe3 SAS adapters.
- Attributes provided: high speed connection between two PCIe2 or two PCIe3 SAS adapters with write cache
- Attributes required: available top connectors on pair of PCIe2 or PCIe3 SAS adapters with write cache
- For 8205-E6D: (#ECC4)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ECSC) - Custom Service Specify, Shenzhen, China
Having #ESCS on the order, will cause the order to be routed to Shenzhen and the machine to be internally routed to the CSC build area.- Attributes provided: Customization
- Attributes required: None
- For 8205-E6D: (#ECSC)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ECSM) - Custom Service Specify, Mexico
Having #ECSM on the order, will cause the order to be routed to Mexico and the machine to be internally routed to the CSC build area.
- Attributes provided: Customization
- Attributes required: None
- For 8205-E6D: (#ECSM)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ECSS) - Integrated Solution Packing
(No Longer Available as of November 30, 2015)
This is a routing indicator for Solution packing.
- Attributes provided: Routing instruction for manufacturing
- Attributes required: None
- For 8205-E6D: (#ECSS)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#ECW0) - Optical Wrap Plug
A wrap plug is a small connector designed to perform a diagnostic test called a loopback test. This wrap plug is inserted into a SR optical port on a PCIe Fibre Channel adapter or a SR or LR optical port on a PCIe Ethernet adapter
This is a multi-mode LC fiber optic wrap plug with an inside/ outside optics diameter of 50/125. Its IBM part number as of early 2016 is 12R9314. An earlier equivalent function IBM part number which is no longer shipped is 11P3847.
It is strongly recommended that Fibre Channel adapters (HBAs) fill any empty adapter ports with a wrap plug. There is no technical issue leaving a port empty. However, filling all ports with a cable to a device/switch or with a wrap plug can speed the booting/IPLing of a partition and can avoid error messages uselessly pointing to a planned empty port.
There is no technical issue leaving an Ethernet port empty. Whether an Ethernet port is empty or contains a wrap plug should not impact boot/IPL time or impact empty-port messages.
- Attributes provided: Wrap plug
- Attributes required: None
- For 8205-E6D: (#ECW0)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#EDR1) - EXP30 Ultra SSD I/O Drawer
(No Longer Available as of August 26, 2016)
#EDR1 is a 1U high I/O drawer providing 30 hot-swap SSD bays and a pair of integrated large write cache, high-performance SAS controllers. Ultra high levels of performance are provided without using any PCIe slots on the POWER7 server in an ultra dense packaging design.This feature is The two high performance, integrated SAS controllers each physically provide 3.1GB write cache. Working as a pair, they provide mirrored write cache data and controller redundancy. The cache contents are designed to be protected by built- in flash memory in case of power failure. If the pairing is broken, write cache is not used after existing cache content is written out to the drive and performance will probably be slowed until the controller pairing is re-established. Each controller is connected to a GX++ PCIe adapter in a server (for example #1914) over a PCIe x8 Cable (example: #EN05 or #EN07 or #EN08). Usually both controllers are attached to one server, but each controller can be assigned to a different server or partition or VIOS. Active/Active capability is supported assuming at least two RAID arrays. The controllers provide RAID 0, RAID 5, RAID 6 and RAID 10 for AIX and Linux and VIOS. AIX/Linux/VIOS also provide OS mirroring (LVM). The adapters' CCIN is 57C3. eMLC SSD designed to fit in the Ultra drawer bays such as the 387GB #ES02 SSD are used. A minimum of six SSDs are required in each Ultra drawer. Each controller can access all 30 SSD bays. The bays can be configured as one set of bays run by a pair of controllers working together. Or the bays can be divided into two logical sets where each of the two controllers "own" one of the logical sets. With proper software if one of the controllers fails, the other controller can run both sets of bays
- Attributes provided: 30 SSD Bays, two integrated SAS adapters
- Attributes required: GX++ slot, GX++ PCIe Adapter and PCIe x8 cable
- For 8205-E6D: (#EDR1)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- System maximum of 4 with AIX/Linux
- System maximum of 2 with IBM i
(#EHK1) - DSW Order Specify Code
DSW Order Specify Code
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#EHK1)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#EHK2) - Solution Specify Code
Solution Specify Code- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#EHK2)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: Supported
- CSU: Yes
- Return parts MES: Does not apply
(#EHSS) - SPSS on Power Solution Indicator
(No Longer Available as of November 30, 2015)
This feature specifies a SPSS on Power Solution. The solution will be integrated at the Customer Solution Center.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#EHSS)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- AIX 6.1 and 7.1 or later supported
- IBM i not suported
- Red Hat Enterprise Linux for Power 6.4, or later
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#ECSP) - Custom Service Specify, Poughkeepsie, USA
Having #ECSP on the order, will cause the order to be routed to Poughkeepsie, USA and the machine to be internally routed to the CSC build area.
- Attributes provided: Customization
- Attributes required: None
- For 8205-E6D: (#ECSP)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: Does not apply
(#EH10) - 387GB SFF-2 SSD converted for AIX/Linux
(No Longer Available as of August 31, 2017)
This special feature code is used when "converting" a four-pack of 387GB SSD which are mounted on a SFF-1 carrier/trays to four features all mounted on SFF-2 carrier/trays. SFF-2 carrier/trays can be placed in an EXP24S I/O Drawer. A special feature code was created because a) the originally announced 387GB SFF-2 feature code is either withdrawn from marketing or b) the server on which it was initially ordered is withdrawn from marketing and the four-pack is an "iniital only" orderable feature. IBM ordering/configuring systems don't support converting to a withdrawn features or initial only features. It was decided to use the same approach for all 4-pack features for consistency even if all feature codes for your specific model are still available. This is ordered using one "remove" and four "adds" in the IBM ordering system and does not use the more common one-to-one feature conversion. IBM ships one SFF-2 carrier/tray with each #EH10 feature ordered. SFF-2 #EH10 is equivalent to one SFF-2 #ES0C. Use when converting fom SFF-1 four pack #ESRA.
- Attributes provided: SFF-2 tray/carrier resulting in feature code representing SFF-2 387GB SSD
- Attributes required: Four-pack of 387GB SSD mounted on a SFF-1 carrier/trays
- For 8205-E6D: (#EH10)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#EH11) - 387GB SFF-2 SSD converted for AIX/Linux
(No Longer Available as of August 31, 2017)
This special feature code is used when "converting" a four-pack of 387GB SSD which are mounted on a SFF-1 carrier/trays to four features all mounted on SFF-2 carrier/trays. SFF-2 carrier/trays can be placed in an EXP24S I/O Drawer. A special feature code was created because a) the originally announced 387GB SFF-2 feature code is either withdrawn from marketing or b) the server on which it was initially ordered is withdrawn from marketing and the four-pack is an "iniital only" orderable feature. IBM ordering/configuring systems don't support converting to a withdrawn features or initial only features. It was decided to use the same approach for all 4-pack features for consistency even if all feature codes for your specific model are still available. This is ordered using one "remove" and four "adds" in the IBM ordering system and does not use the more common one-to-one feature conversion. IBM ships one SFF-2 carrier/tray with each #EH11 feature ordered. SFF-2 #EH11 is equivalent to one SFF-2 #ES19. Use when converting fom SFF-1 four pack #ESRE.
- Attributes provided: SFF-2 tray/carrier resulting in feature code representing SFF-2 387GB SSD
- Attributes required: Four-pack of 387GB SSD mounted on a SFF-1 carrier/trays
- For 8205-E6D: (#EH11)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#EH12) - 387GB SFF-2 SSD converted for IBM i
(No Longer Available as of August 31, 2017)
This special feature code is used when "converting" a four-pack of 387GB SSD which are mounted on a SFF-1 carrier/trays to four features all mounted on SFF-2 carrier/trays. SFF-2 carrier/trays can be placed in an EXP24S I/O Drawer. A special feature code was created because a) the originally announced 387GB SFF-2 feature code is either withdrawn from marketing or b) the server on which it was initially ordered is withdrawn from marketing and the four-pack is an "iniital only" orderable feature. IBM ordering/configuring systems don't support converting to a withdrawn features or initial only features. It was decided to use the same approach for all 4-pack features for consistency even if all feature codes for your specific model are still available. This is ordered using one "remove" and four "adds" in the IBM ordering system and does not use the more common one-to-one feature conversion. IBM ships one SFF-2 carrier/tray with each #EH12 feature ordered. SFF-2 #EH12 is equivalent to one SFF-2 #ES0D. Use when converting fom SFF-1 four pack #ESRB.
- Attributes provided: SFF-2 tray/carrier resulting in feature code representing SFF-2 387GB SSD
- Attributes required: Four-pack of 387GB SSD mounted on a SFF-1 carrier/trays
- For 8205-E6D: (#EH12)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#EH13) - 387GB SFF-2 SSD converted for IBM i
(No Longer Available as of August 31, 2017)
This special feature code is used when "converting" a four-pack of 387GB SSD which are mounted on a SFF-1 carrier/trays to four features all mounted on SFF-2 carrier/trays. SFF-2 carrier/trays can be placed in an EXP24S I/O Drawer. A special feature code was created because a) the originally announced 387GB SFF-2 feature code is either withdrawn from marketing or b) the server on which it was initially ordered is withdrawn from marketing and the four-pack is an "iniital only" orderable feature. IBM ordering/configuring systems don't support converting to a withdrawn features or initial only features. It was decided to use the same approach for all 4-pack features for consistency even if all feature codes for your specific model are still available. This is ordered using one "remove" and four "adds" in the IBM ordering system and does not use the more common one-to-one feature conversion. IBM ships one SFF-2 carrier/tray with each #EH13 feature ordered. SFF-2 #EH13 is equivalent to one SFF-2 #ES1A. Use when converting fom SFF-1 four pack #ESRF.
- Attributes provided: SFF-2 tray/carrier resulting in feature code representing SFF-2 387GB SSD
- Attributes required: Four-pack of 387GB SSD mounted on a SFF-1 carrier/trays
- For 8205-E6D: (#EH13)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#EH14) - GEN2-S Conversion Carrier for Feature ES0C 387GB SSD
(No Longer Available as of August 31, 2017)
This feature delivers one GEN2-S carrier as a MES upgrade. The carrier #EH14 accommodates one #ES0A 387GB SFF-1 SSD for AIX/Linux so it can be installed as a conversion in a GEN2 bay such as #5887 EXP24S SFF Gen2-bay Drawer. It is now functionally equivalent to #ES0C.
- Attributes provided: One GEN2 Carrier
- Attributes required: None
- For 8205-E6D: (#EH14)
- Minimum required: 0
- Maximum allowed: 336 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#EH16) GEN2-S Conversion Carrier for Feature ES0D 387GB SSD (IBM i)
(No Longer Available as of August 31, 2017)
This feature delivers a GEN2-S carrier as a MES upgrade. The carrier #EH16 accommodates #ES0B 387GB SFF-2 SSD for IBM i with eMLC. Once on the carrier it can be installed in a GEN2 bay such as #5887 EXP24S SFF Gen2-bay Drawer. It is now functionally equivalent to #ES0D.
- Attributes provided: One GEN2 Carrier
- Attributes required: None
- For 8205-E6D: (#EH16)
- Minimum required: 0
- Maximum allowed: 336 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#EJ01) - Storage Backplane -- 8 SFF Bays/175MB RAID/Dual IOA
This feature provides a storage backplane which supports eight SFF (Small Form Factor) storage HDDs or SSDs with paired dual controller support, dual 175MB Cache RAID, RAID-5/6 enablement and an external SAS port. The backplane supports connection for a slimline SATA DVD and a half high tape bay for either a tape drive or USB removable disk. No PCI slot is used for the internal controllers. This feature is required by IBM i to natively use the internal storage (HDDs/SSDs and media) and the system SAS port.
- Attributes provided: Storage backplane
- Attributes required: None
- For 8205-E6D: (#EJ01)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJ02) - Split Drive Bay Capability for #5618
Optional SAS controller which splits the six drive bays of Storage Backplane #5618 into a pair of three drive bay groups and enables RAID-10 capability. No PCI slot is used for the controller. Not orderable with Storage Backplane #EJ01. This feature does not provide RAID-5/6 capability.
- Attributes provided: Ability to split #5618 backplane
- Attributes required: #5618 storage backplane
- For 8205-E6D: (#EJ02)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJ03) - GX++ 2-port PCIe2 x8 Adapter
(No Longer Available as of March 31, 2018)
The #EJ03 adapter enables the attachment of the EXP30 Ultra SSD I/ O Drawer (#5888/#EDR1). The EJ03 is plugged into a GX++ slot of the 4U Power 720 or 740. Two PCIe cables such as EN05 or EN07 then connects the #EJ03 and the #5888/#EDR1.
- Attributes required: Available GX++ slot position
- For 8205-E6D: (#EJ03)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 2)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJ04) - GX++ Dual-port 12x Channel Attach
(No Longer Available as of March 31, 2018)
GX++ Dual-port 12X Channel Adapter, provides two 12X connections for 12X Channel applications. This adapter allows the attachment of I/O Drawers designed for the 12X Channel. The adapter plugs into a GX++ bus slot in a system enclosure. The 12X Channel is connected in a loop and uses both connectors on the adapter. Up to four I/O Drawers can be attached in a single loop. This adapter must be used with the 12X cables. Connection to supported InfiniBand switches is accomplished by using the 12x to 4x Channel Conversion Cables, #1828, #1841 or #1842.
- Attributes provided: Two 12X Channel remote I/O ports
- Attributes required: Available GX++ slot
- For 8205-E6D: (#EJ04)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 2)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJ10) - PCIe3 SAS Tape/DVD Adapter Quad-port 6Gb x8
(No Longer Available as of March 31, 2018)
The PCIe3 SAS Adapter is a high performance SAS tape controller using PCIe Gen3 x8 technology. It supports LTO-5 or LTO-6 tape drives and DVD. The adapter provides four Mini-SAS HD (high density) connectors to which AE1 SAS cables such as #ECBY and/or YE1 SAS Cables such as #ECBZ with HD narrow connectors can be attached. A max of 4 tape drives per adapter can be attached using four AE1 cables. A max of 8 tape drives can be attached using four YE1 cables.
#EJ10 (full high) and #EJ11 (low profile) are electronically the same adapter with the same 57B4 CCIN, but differ in that their tailstocks fit different size PCIe slots.
#EJ0J and #EJ10 are the same adapter with the same 57B4 CCIN, but have different feature code numbers to indicate different usage to IBM configurator tools. #EJ10 runs SAS LTO-5/LTO-6 tape drives and DVD. Support of both tape/DVD and HDD/SSD on the same adapter is not supported.
Note the original #EJ0X adapter does not support DVD but also has the same CCIN.
Note: Adapter uses a Mini-SAS HD narrow connector and AE1 #ECBZ or YE1 #ECBY SAS cable
Limitation: LTO-4 or earlier drives are not supported.
- Attributes provided: full high PCIe3 four port x8 SAS adapter
- Attributes required: One PCIe slot per adapter
- For 8205-E6D: (#EJ10)
- Minimum required: 0
- Maximum allowed: 42 (Initial order maximum: 42)
- OS level required:
- AIX V7.1 with the 7100-03 Technology Level and Service Pack 1 or later
- AIX V6.1 with the 6100-09 Technology Level and Service Pack 1 or later
- IBM i 6.1, or later
- IBM i 7.1, or later
- SUSE Linux Enterprise Server 11 Service Pack 3 for POWER, with current maintenance updates available from SUSE to enable all planned functionality
- Red Hat Enterprise Linux 6.4, for POWER, or later
- Users should also update their systems with the latest Linux for
POWER service and productivity tools from the IBM website
http://www14.software.ibm.com/webapp/set2/sas/f/lopdiags/home.html
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note: Attachment to the VIOS requires VIOS 2.2.3.1 or later
(#EJ11) - PCIe3 LP SAS Tape/DVD Adapter Quad-port 6Gb x8
(No Longer Available as of March 31, 2018)
The PCIe3 Low Profile SAS Adapter is a high performance SAS tape controller using PCIe Gen3 x8 technology. It supports LTO-5 or LTO-6 tape drives and DVD. The adapter provides four Mini-SAS HD (high density) connectors to which AE1 SAS cables such as #ECBY and/or YE1 SAS Cables such as #ECBZ with HD narrow connectors can be attached. A max of 4 tape drives per adapter can be attached using four AE1 cables. A max of 8 tape drives can be attached using four YE1 cables.
#EJ10 (full high) and #EJ11 (low profile) are electronically the same adapter with the same 57B4 CCIN, but differ in that their tailstocks fit different size PCIe slots.
#EJ0M and #EJ11 are the same adapter with the same 57B4 CCIN, but have different feature code numbers to indicate different usage to IBM configurator tools. #EJ11 runs SAS LTO-5/LTO-6 tape drives and DVD. Support of both tape/DVD and HDD/SSD on the same adapter is not supported.
Limitation: LTO-4 or earlier drives are not supported.
- Attributes provided: low profile PCIe3 four port x8 SAS adapter
- Attributes required: One low profile PCIe slot per adapter; Mini-SAS HD narrow connector SAS cables AE1 #ECBZ or YE1 #ECBY
- For 8205-E6D: (#EJ11)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 2)
- OS level required:
- AIX V7.1 with the 7100-03 Technology Level and Service Pack 1 or later
- AIX V6.1 with the 6100-09 Technology Level and Service Pack 1 or later
- IBM i 6.1, or later
- IBM i 7.1, or later
- SUSE Linux Enterprise Server 11 Service Pack 3 for POWER, with current maintenance updates available from SUSE to enable all planned functionality
- Red Hat Enterprise Linux 6.4, for POWER, or later
- Users should also update their systems with the latest Linux for
POWER service and productivity tools from the IBM website
http://www14.software.ibm.com/webapp/set2/sas/f/lopdiags/home.html
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note: Attachment to the VIOS requires VIOS 2.2.3.1 or later
(#EJ27) - PCIe Crypto Coprocessor No BSC 4765-001
(No Longer Available as of March 31, 2017)
Secure-key adapter provides both cryptographic coprocessor and cryptographic accelerator functions in a single PCIe card. The adapter is well suited to applications requiring high-speed, security- sensitive, RSA acceleration, cryptographic operations for data encryption and digital signing, secure management, and use of cryptographic keys, or custom cryptographic applications. It provides secure storage of cryptographic keys in a tamper-resistant hardware security module designed to meet FIPS 140-2 level 4 security requirements. The adapter is a PCIe 4x full height - short card.
#EJ27, #EJ28 and #EJ29 are all feature codes representing the same physical card with the same CCIN of 4765, but different feature codes are used to indicate if a blind swap cassette is used and its type. #EJ27 indicates no blind swap cassette. #EJ28 indicates a Gen 3 blind swap cassette. #EJ29 indicates a Gen 4 blind swap cassette.
#EJ27, EJ28 and EJ29 are identical to #4807, #4808 and #4809 adapters which were manufactured after 2012, but different from #4807, #4808 and #4809 adapters manufactured prior to 2012.
Other IBM PCIe Cryptographic Coprocessor adapter highlights
- Integrated Dual processors that operate in parallel for higher reliability
- Supports IBM Common Cryptographic Architecture or PKCS#11 standand
- Ability to configure adapter as coprocessor or accelerator
- Support for smart card applications using Europay, MasterCard and Visa
- Cryptographic key generation and random number generation
- PIN processing - generation, verification, translation
- Encrypt/Dectrypt using AES and DES keys
Refer to the following URL for the latest firmware and software update
- Attributes provided: Cryptographic Coprocessor and Accelerator Functions
- Attributes required: One full-high PCIe slot which does not use a blind swap cassette
- For 8205-E6D: (#EJ27)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 2)
- OS level required:
- AIX Version 5.3 supported
- AIX 7.1 supported
- AIX 6.1 supported
- IBM i 6.1 with machine code 6.1.1
- IBM i 7.1 or later
- IBM i 7.2 or later
- Linux - not supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJ28) - PCIe Crypto Coprocessor Gen3 BSC 4765-001
(No Longer Available as of March 31, 2017)
Secure-key adapter provides both cryptographic coprocessor and cryptographic accelerator functions in a single PCIe card. The adapter is well suited to applications requiring high-speed, security- sensitive, RSA acceleration, cryptographic operations for data encryption and digital signing, secure management, and use of cryptographic keys, or custom cryptographic applications. It provides secure storage of cryptographic keys in a tamper-resistant hardware security module designed to meet FIPS 140-2 level 4 security requirements. The adapter is a PCIe 4x full height - short card.
#EJ27, #EJ28 and #EJ29 are all feature codes representing the same physical card with the same CCIN of 4765, but different feature codes are used to indicate if a blind swap cassette is used and its type. #EJ27 indicates no blind swap cassette. #EJ28 indicates a Gen 3 blind swap cassette. #EJ29 indicates a Gen 4 blind swap cassette. 2
#EJ27, EJ28 and EJ29 are identical to #4807, #4808 and #4809 adapters which were manufactured after 2012, but different from #4807, #4808 and #4809 adapters manufactured prior to 2012.
Other IBM PCIe Cryptographic Coprocessor adapter highlights
- Integrated Dual processors that operate in parallel for higher reliability
- Supports IBM Common Cryptographic Architecture or PKCS#11 standand
- Ability to configure adapter as coprocessor or accelerator
- Support for smart card applications using Europay, MasterCard and Visa
- Cryptographic key generation and random number generation
- PIN processing - generation, verification, translation
- Encrypt/Dectrypt using AES and DES keys
Refer to the following URL for the latest firmware and software updates.
- Attributes provided: Cryptographic Coprocessor and Accelerator Functions
- Attributes required: One full-high PCIe slot using a gen3 blind swap cassette such as found in an EM0X Gen3 I/O drawer or #5802/5803/5873/5877 12X-attached I/O drawer
- For 8205-E6D: (#EJ28)
- Minimum required: 0
- Maximum allowed: 8 (Initial order maximum: 8)
- OS level required:
- AIX Version 5.3 supported
- AIX 6.1 supported
- AIX 7.1 supported
- IBM i 6.1 with machine code 6.1.1
- IBM i 7.1 or later
- IBM i 7.2 or later
- Linux - not supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJ0J) - PCIe3 RAID SAS Adapter Quad-port 6 Gb x8
(No Longer Available as of March 31, 2018)
The PCIe3 RAID SAS Adapter is a high performance SSD/HDD controller using PCIe Gen3 x8 technology. The adapter does not have write cache and thus pairing with another PCIe3 RAID SAS Adapter (#EJ0J or #EJ0M) is optional. Pairing can provide controller redundancy and enhance performance. There are no batteries in the adapter to maintain.dapter to maintain.
The adapter provides four Mini-SAS HD (high density) narrow connectors for the attachment of SAS drives located in the EXP24S, EXP12SX or EXP24SX storage enclosures or #5802/5803/EL36 12X PCIe I/O drawers. X, YO or AT SAS cables with HD narrow connectors are used to attach to these drawers. A max of 4 EXP24S/EXP12SX/EXP24SX can be attached. A maximum of 48 SSD can be attached and a maximum of 96 HDD can be attached per adapter or per adapter pair.
The adapter provides RAID 0, RAID 5, RAID 6 and RAID 10 for AIX and Linux and VIOS. The adapter provides RAID 5 and RAID 6 for all levels of IBM i and also provides RAID 10 for later levels of IBM i. IBM i provides both OS mirroring and data spreading. AIX/Linux/VIOS provide OS mirroring (LVM).
Features #EJ0J and #EJ0M are electronically identical with the same CCIN of 57B4. #EJ0J has a full-high tailstock bracket and air baffle. #EJ0M has a low profile tailstock bracket. #EJ10/#EJ11 are identical with #EJ0J/#EJ0M, but have different feature codes to identify their use as tape/DVD controllers to IBM configurator tools instead of disk/SSD controllers.
Both 5xx and 4k byte sector HDD/SSD are supported for POWER8 servers. 5xx byte sector HDD/SSD are supported for earlier generation servers. 5xx and 4k drives cannot be mixed in the same array..
Limitations:
- HDD/SSD workloads which are performance sensitive to WRITES should use the #EJ14 or #EJ0L controller which provides write cache.
- HDD and SSD cannot be mixed on the same SAS port, but can be mixed on the same adapter.
- #5886 3.5-inch SAS Storage Drawer is not supported.
- 177 GB SSD are not supported.
- Running SAS bays for both a #5887 EXP24S I/O drawer and a 12X-attached #5802/5803 I/O drawer on the same adapter or adapter pair is not supported. Note mixing EXP24S or EXP12SX or EXP24SX is supported.
- If controlling drives in a #5802/5803/EL36 as a single controller, the #EJ0J must be located in that #5802/5803/EL36. If controlling drives in a #5802/5803/EL36 as a pair of controllers, at least one of the SAS adapter pairs must be located in that #5802/5803/EL36.
- Tape/DVD cannot be mixed with disk/SSD on the same adapter.
- Attributes provided: full high PCIe3 four port x8 SAS RAID adapter with no write cache and optional pairing.
- Attributes required: One PCIe slot per adapter and Mini-SAS HD narrow connector SAS cables such as #ECBJ-ECBL, #ECBT-ECBV, #ECCO-ECC4 or 12 Gb cables such as #ECDJ, ECDT or #ECDU.
- For 8205-E6D: (#EJ0J)
- Minimum required: 0
- Maximum allowed: 42 (Initial order maximum: 42)
- OS level required:
- AIX V7.1 with the 7100-03 Technology Level and Service Pack 1 or later
- AIX V6.1 with the 6100-09 Technology Level and Service Pack 1 orlater
- IBM i 6.1 with machine code 6.1.1
- IBM i 7.1 or later
- SUSE Linux Enterprise Server 11 Service Pack 3 for POWER, with current maintenance updates available from SUSE to enable all planned functionality
- Red Hat Enterprise Linux 6.4, for POWER, or later
- Users should also update their systems with the latest Linux for POWER service and productivity tools from the IBM website
- http://www14.software.ibm.com/webapp/set2/sas/f/lopdi ags/home.html
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note: Max 2 in CEC
Note: Max 10 per #5802/#5877 not to exceed system Max
Note: Attachment to the VIOS requires VIOS 2.2.3.1 or later
(#EJ0L) - PCIe3 12 GB Cache RAID SAS Adapter Quad-port 6 Gb x8
(No Longer Available as of March 31, 2018)
The PCIe3 12 GB Cache RAID SAS Adapter provides high performance HDD and/or SSD controller function using PCIe Gen3 technology. A pair of adapters are required to provide mirrored write cache data and adapter redundancy. Integrated flash memory provides protection of the write cache without batteries in case of power failure. Effectively up to 12 GB of write cache is provided using compression of 4 GB of physical cache.
The adapter provides four Mini-SAS HD (high density) narrow connectors for the attachment of SAS drives located in the SAS EXP24S or EXP12SX or EXP24SX storage enclosures or #5802/5803/EL36 12X PCIe I/O drawers. X, YO or AT SAS cables with HD narrow connectors are used to attach to these drawers. A max of 4 EXP24S/EXP12SX/EXP24SX can be attached with a maximum of 96 HDD or a maximum of 48 SSD. Two AA SAS cable with HD narrow connectors are attached to the #EJ0L pair to communicate status and cache content information and are required unless three or four ports are being used to attach HDD/SSD.
The #EJ0L provides RAID 0, RAID 5, RAID 6 and RAID 10 for AIX and Linux and VIOS. The adapter provides RAID 5 and RAID 6 for all levels of IBM i and also provides RAID 10 for later levels of IBM i. IBM i provides both OS mirroring and data spreading. AIX/Linux/VIOS provide OS mirroring (LVM). This adapter can also support the Easy Tier function (RAID 52T, 62T or 102T) for AIX and Linux. The adapter's CCIN is 57CE.
Both 5xx and 4k byte sector HDD/SSD are supported for POWER8 servers. 5xx byte sector HDD/SSD are supported for earlier generation servers. 5xx and 4k drives cannot be mixed in the same array.
Limitations:
- HDD and SSD cannot be mixed on the same SAS port, but can be mixed on the same adapter.
- #5886 3.5-inch SAS I/O Drawer is not supported.
- 177 GB SSD are not supported.
- Running SAS bays for both a #5887 EXP24S I/O drawer and a 12X-attached #5802/5803 I/O drawer on the same adapter pair is not supported. Note mixing EXP24S or EXP12SX or EXP24SX is supported.
- If controlling drives in a #5802/5803/EL36 at least one of the #EJ0L pairs must be located in that #5802/5803/EL36.
- Attributes provided: full high PCIe3 four port x8 adapter with up to 12 GB write cache.
- Attributes required: One PCIe slot per adapter and Mini-SAS HD narrow connector SAS cables such as #ECBJ-ECBL, #ECBT-ECBV, #ECCO-ECC4.or 12 Gb cables such as ECDT or #ECDU.
- For 8205-E6D: (#EJ0L)
- Minimum required: 0
- Maximum allowed: 34 (Initial order maximum: 34)
- OS level required:
- AIX V7.1 with the 7100-03 Technology Level and Service Pack 1 or later
- AIX V6.1 with the 6100-09 Technology Level and Service Pack 1 or later
- IBM i 6.1 with machine code 6.1.1
- IBM i 7.1 or later
- SUSE Linux Enterprise Server 11 Service Pack 3 for POWER, with current maintenance updates available from SUSE to enable all planned functionality
- Red Hat Enterprise Linux 6.4, for POWER, or later
- Users should also update their systems with the latest Linux for POWER service and productivity tools from the IBM website
- http://www14.software.ibm.com/webapp/set2/sas/f/lopdi ags/home.html
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note: Attachment to the VIOS requires VIOS 2.2.3.1 or later.
Easy Tier requires:
- AIX V7.1 with the 7100-03 Technology Level and Service Pack 3 or later (planned availability 6/10/2014)
- AIX V6.1 with the 6100-09 Technology Level and Service Pack 3 or later (planned availability 6/10/2014) when used in the VIOS, VIOS 2.2.3.3 or later (planned availability 6/10/2014)
- SUSE Linux Enterprise Server 11 Service Pack 3 for POWER, with current maintenance updates available from SUSE to enable all planned functionality
- Red Hat Enterprise Linux 6.5, for POWER, or later
- Users should also update their systems with the latest Linux for POWER service and productivity tools from the IBM website
- http://www14.software.ibm.com/webapp/set2/sas/f/lopdi ags/home.html
(#EJ0M) - PCIe3 LP RAID SAS ADAPTER Quad-Port 6Gb x8
(No Longer Available as of March 31, 2018)
The PCIe3 RAID SAS LP Adapter is a high performance SSD/HDD controller using PCIe Gen3 x8 technology. The adapter does not have write cache and thus pairing with another PCIe3 RAID SAS Adapter (#EJ0M or #EJ0J) is optional. Pairing can provide controller redundancy and enhance performance. There are no batteries in the adapter to maintain.
The adapter provides four Mini-SAS HD (high density) narrow connectors for the attachment of SAS drives located in the EXP24S, EXP12SX, EXP24SX storage enclosure or #5802/EL36 12X PCIe I/O drawers. X, YO or AT SAS cables with HD narrow connectors are used to attach to these drawers. A max of 4 EXP24S/EXP12SX/EXP24SX can be attached. A maximum of 48 SSD can be attached and a maximum of 96 HDD can be attached per adapter or per adapter pair.
The adapter provides RAID 0, RAID 5, RAID 6 and RAID 10 for AIX and Linux and VIOS. The adapter provides RAID 5 and RAID 6 for all levels of IBM i and also provides RAID 10 for later levels of IBM i. IBM i provides both OS mirroring and data spreading. AIX/Linux/VIOS provide OS mirroring (LVM).
Features #EJ0J and #EJ0M are electronically identical with the same CCIN of 57B4. #EJ0J has a full-high tailstock bracket and air baffle. #EJ0M has a low profile tailstock bracket. #EJ10 / #EJ11 are identical with #EJ0J / #EJ0M respectively, but have different feature codes to identify their use to IBM configurator tools as tape/DVD controllers instead of disk/SSD controllers.
Both 5xx and 4k byte sector HDD/SSD are supported for POWER8 servers. 5xx byte sector HDD/SSD are supported for earlier generation servers. 5xx and 4k drives cannot be mixed in the same array.
Limitations:
- HDD/SSD workloads which are performance sensitive to WRITES should use the #EJ14 or #EJ0L controller which provide write cache.
- HDD and SSD cannot be mixed on the same SAS port, but can be mixed on the same adapter.
- #5886 3.5-inch SAS Storage Drawer is not supported.
- 177 GB SSD are not supported.
- Running SAS bays for both a EXP24S storage drawer and a 12X-attached #5802/5803 I/O drawer on the same adapter or adapter pair is not supported. Note mixing EXP24S or EXP12SX or EXP24SX is supported.
- A single #EJ0M cannot control drives in a #5802/5803/EL36 because the adapter must be located in that #5802/5803/ EL36 in a full high slot. However, if controlling drives in a #5802/5803/EL36 as a pair of controllers, one #EJ0J can be located in that #5802/5803/EL36 and one #EJ0M can be in the system's low profile slot.
- Tape/DVD cannot be mixed with disk/SSD on the same adapter.
- Attributes provided: low profile PCIe3 four port x8 SAS RAID adapter with no write cache and optional pairing Attributes required: One low profile PCIe slot per adapter and Mini-SAS HD narrow connector SAS cables such as #ECBJ-ECBL, #ECBT-ECBV, #ECCO-ECC4 or 12 Gb cables such as #ECDJ, ECDT or #ECDU.
- For 8205-E6D: (#EJ0M)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 2)
- OS level required:
- AIX V7.1 with the 7100-03 Technology Level and Service Pack 1 or later
- AIX V6.1 with the 6100-09 Technology Level and Service Pack 1 or later
- IBM i 6.1, or later
- IBM i 7.1, or later
- SUSE Linux Enterprise Server 11 Service Pack 3 for POWER, with current maintenance updates available from SUSE to enable all planned functionality
- Red Hat Enterprise Linux 6.4, for POWER, or later
- Users should also update their systems with the latest Linux for POWER service and productivity tools from the IBM website
- http://www14.software.ibm.com/webapp/set2/sas/f/lopdi ags/home.html
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note: Attachment to the VIOS requires VIOS 2.2.3.1 or later
(#EJP1) - Specify Mode-1 1(1)ESA1/ESA2 for EXP24S #5887
Feature indicates that EXP24S SFF Gen2-bay Drawer (#5887) will be configured by IBM Manufacturing in Mode 1 (One group of 24 drive bays) with one PCIe 6G SAS controller (#ESA1 or #ESA2), utilizing one appropriate YO cable connecting to the I/O Adapter (IOA) ports. IBM does not provide changes to the mode setting after #5887 is shipped.
Supported by AIX and Linux.
- Attributes provided: IOA configuration for Mode 1
- Attributes required: One YO cable (#3450 1.5M, #3451 3M, #3452 6M, #3453 10M) and one port on a #ESA1/ESA2
- For 8205-E6D: (#EJP1)
- Minimum required: 0
- Maximum allowed: 14 (Initial order maximum: 14)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJP2) - Specify Mode-1 1(2)ESA1/ESA2 for EXP24S #5887
Feature indicates that EXP24S SFF Gen2-bay Drawer (#5887) will be configured by IBM Manufacturing in Mode 1 (One group of 24 drive bays) with two PCIe 6G SAS controllers (#ESA1 or #ESA2), utilizing two appropriate YO cables connecting to the I/O Adapter (IOA) ports. IBM does not provide changes to the mode setting after #5887 is shipped.
Supported by AIX and Linux
- Attributes provided: IOA configuration for Mode 1
- Attributes required: Two YO cables (#3450 1.5M, #3451 3M, #3452 6M, #3453 10M) and one port each on two #ESA1/ESA2
- For 8205-E6D: (#EJP2)
- Minimum required: 0
- Maximum allowed: 14 (Initial order maximum: 14)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJP3) Specify Mode-2 1(2)ESA1/ESA2 1(2) X for EXP24S #5887 or #EL1S
Feature indicates that EXP24S SFF Gen2-bay Drawer (#5887) will be configured by IBM Manufacturing in Mode 2 (two groups of 12 drive bays) with two PCIe 6G SAS controllers (#ESA1 or #ESA2), utilizing two appropriate X cable connecting to the I/O Adapter (IOA) ports. IBM does not provide changes to the mode setting after #5887 is shipped.
Supported by AIX and Linux.
- Attributes provided: IOA configuration for Mode 2
- Attributes required: Two X cables (#3454 3M, #3455 6M, #3456 10M) and two ports on each of two #ESA1/ESA2
- For 8205-E6D: (#EJP3)
- Minimum required: 0
- Maximum allowed: 14 (Initial order maximum: 14)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJP4) - Specify Mode-2 1(4)ESA1/ESA2 for EXP24S #5887
Feature indicates that EXP24S SFF Gen2-bay Drawer (#5887) will be configured by IBM Manufacturing in Mode 2 (two groups of 12 drive bays) with four PCIe 6G SAS controllers (#ESA1 or #ESA2), utilizing two appropriate X cable connecting to the I/O Adapter (IOA) ports. IBM does not provide changes to the mode setting after #5887 is shipped.
Supported by AIX and Linux.
- Attributes provided: IOA configuration for Mode 2
- Attributes required: Two X cables (#3454 3M, #3455 6M, #3456 10M) and one ports on each of four #ESA1/ESA2
- For 8205-E6D: (#EJP4)
- Minimum required: 0
- Maximum allowed: 10 (Initial order maximum: 10)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJP5) - Specify Mode-4 1(4)ESA1/ESA2 for EXP24S #5887
Feature indicates that EXP24S SFF Gen2-bay Drawer (#5887) will be configured by IBM Manufacturing in Mode 4 (four groups of 6 drive bays) with four PCIe 6G SAS controllers (#ESA1 or #ESA2), utilizing two appropriate X cable connecting to the I/O Adapter (IOA) ports. IBM does not provide changes to the mode setting after #5887 is shipped.
Supported by AIX and Linux.
- Attributes provided: IOA configuration for Mode 4
- Attributes required: Two X cables (#3454 3M, #3455 6M, #3456 10M) and one ports on each of four #ESA1/ESA2
- For 8205-E6D: (#EJP5)
- Minimum required: 0
- Maximum allowed: 10 (Initial order maximum: 10)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJP6) Specify Mode-2 1(1)ESA1/ESA2 1(2) YO for EXP24S #5887 or #EL1S
Feature indicates that EXP24S SFF Gen2-bay Drawer (#5887) will be configured by IBM Manufacturing in Mode 2 (two groups of 12 drive bays) with one PCIe 6G SAS controller (#ESA1 or #ESA2), utilizing two appropriate YO cable connecting to the I/O Adapter (IOA) ports. IBM does not provide changes to the mode setting after #5887 is shipped.
Supported by AIX and Linux.
- Attributes provided: IOA configuration for Mode 2
- Attributes required: Two YO cables (#3450 1.5M, #3451 3M, #3452 6M, #3453 10M) and two ports on either #ESA1 or #ESA2
- For 8205-E6D: (#EJP6)
- Minimum required: 0
- Maximum allowed: 14 (Initial order maximum: 14)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJP7) Specify Mode-2 (2 )ESA1/ESA2 1(2) YO for EXP24 #5887 or #EL1S
Feature indicates that EXP24 SFF Gen2-bay Drawer (#5887) will be configured by IBM Manufacturing in Mode 2 (configured to access all 24 bays) with two PCIe2 RAID SAS Adapter Dual-port 6Gb controllers (#ESA1 and/or #ESA2) utilizing two appropriate YO cables connecting to I/O Adapter (IOA) ports.
- Attributes provided: Designated #5887 configurations for Mode 2
- Attributes required: Two 6G YO Cables
- For 8205-E6D: (#EJP7)
- Minimum required: 0
- Maximum allowed: 14 (Initial order maximum: 14)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJPA) Specify mode-2 (1) ESA1/ESA2 1(1) YO for EXP24 #5887 or #EL1S
Feature indicates that one EXP24 SFF Gen2-bay Drawer (#5887) will be configured to Mode 2 (two groups of 12 drive bays) with only one group of 12 drive bays enabled by connecting to one PCIe2 RAID SAS Adapter Dual-port 6Gb controller (#ESA1 or #ESA2) using one appropriate 6G YO cable. IBM does not provide changes to the mode setting after #5887 is shipped.
- Attributes provided: Designated #5887 configuration in Mode 2 with 12 drive bays enabled
- Attributes required: One 6G YO cable (#3450 1.5M, #3451 3m, #3452 6m, #3453 10m,) and one (ESA1/ESA2) dedicated to the single #5887
- For 8205-E6D: (#EJPA)
- Minimum required: 0
- Maximum allowed: 14 (Initial order maximum: 14)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJPB) Specify mode-2 (2)ESA1/ESA2 1(1) X for EXP24#5887 or #EL1S
Feature indicates that one EXP24 SFF Gen2-bay Drawer (#5887) will be configured to Mode 2 (two groups of 12 drive bays) with only one group of 12 drive bays enabled by connecting to two PCIe2 RAID SAS Adapter Dual-port 6Gb controller (#ESA1 and/or #ESA2) using one appropriate 6G X cable. IBM does not provide changes to the mode setting after #5887 is shipped.
- Attributes provided: Designated #5887 configuration in Mode 2 with 12 drive bays enabled
- Attributes required: One 6G dual X cable (#3454 3M, #3455 6M, #3456 10m,) and two (ESA1/ ESA2) dedicated to the single #5887
- For 8205-E6D: (#EJPB)
- Minimum required: 0
- Maximum allowed: 14 (Initial order maximum: 14)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJPC) - Specify mode-4 (1)ESA1/ESA2 for EXP24 #5887
Feature indicates that EXP24S SFF Gen2-bay Drawer (#5887) will be configured to Mode 4 (four groups of 6 drive bays) with only one group of 6 drive bays enabled by connecting to one PCIe2 RAID SAS Adapter Dual-port 6Gb controller (#ESA1 or #ESA2) using one appropriate 6G X cable connecting to only one adapter port. IBM does not provide changes to the mode setting after #5887 is shipped.
- Attributes provided: Designated #5887 configuration in Mode 4 with 6 drive bays enabled.
- Attributes required: One 6G dual X cable (#3454 3M or #3455 6M or #3456 10m) and one (ESA1/ESA2) dedicated to the single #5887
- For 8205-E6D: (#EJPC)
- Minimum required: 0
- Maximum allowed: 14 (Initial order maximum: 14)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJPD) - Specify mode-4 (2)ESA1/ESA2 for EXP24 #5887
Feature indicates that EXP24S SFF Gen2-bay Drawer (#5887) will be configured to Mode 4 (four groups of 6 drive bays) with two groups of 6 drive bays enabled by connecting to two PCIe2 RAID SAS Adapter Dual-port 6Gb controllers (#ESA1 or #ESA2) using one appropriate 6G X cable connecting to only one adapter port on each controller. IBM does not provide changes to the mode setting after #5887 is shipped.
- Attributes provided: Designated #5887 configuration in Mode 4 with 12 drive bays enabled
- Attributes required: One 6G dual X cable (#3454 3M or #3455 6M or #3456 10m) and two (ESA1/ESA2) dedicated to the single #5887
- For 8205-E6D: (#EJPD)
- Minimum required: 0
- Maximum allowed: 14 (Initial order maximum: 14)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJPE) - Specify mode-4 (3)ESA1/ESA2 for EXP24 #5887
Feature indicates that EXP24S SFF Gen2-bay Drawer (#5887) will be configured to Mode 4 (four groups of 6 drive bays) with three groups of 6 drive bays enabled by connecting to three PCIe2 RAID SAS Adapter Dual-port 6Gb controllers (#ESA1 or #ESA2) using two appropriate 6G X cables connecting to only one adapter port on each controller. IBM does not provide changes to the mode setting after #5887 is shipped
- Attributes provided: Designated #5887 configuration in Mode 4 with 18 drive bays enabled
- Attributes required: Two 6G dual X cables (#3454 3M or #3455 6M or #3456 10m) and three (ESA1/ESA2) dedicated to the single #5887
- For 8205-E6D: (#EJPE)
- Minimum required: 0
- Maximum allowed: 14 (Initial order maximum: 14)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJPJ) - Specify mode-2 (1)5901/5278 for EXP24 #5887
Feature indicates that one EXP24 SFF Gen2-bay Drawer (#5887) will be configured to Mode 2 (two groups of 12 drive bays) with only one group of 12 drive bays enabled by connecting to one PCIe 3G SAS controller (5901/5278) using one appropriate YO cable. IBM does not provide changes to the mode setting after #5887 is shipped."
- Attributes provided: Designated #5887 configuration in Mode 2 with 12 drive bays enabled
- Attributes required: One YO cable (#3691 1.5M, #3692 3M, #3693 6M, #3694 15M) and one (5901/5278) dedicated to the single #5887
- For 8205-E6D: (#EJPJ)
- Minimum required: 0
- Maximum allowed: 14 (Initial order maximum: 14)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJPK) - Specify mode-2 (2)5901/5278 for EXP24 #5887
Feature indicates that one EXP24 SFF Gen2-bay Drawer (#5887) will be configured to Mode 2 (two groups of 12 drive bays) with only one group of 12 drive bays enabled by connecting to two PCIe 3G SAS controllers (5901/5278) using one appropriate X cable. IBM does not provide changes to the mode setting after #5887 is shipped.
- Attributes provided: Designated #5887 configuration in Mode 2 with 12 drive bays enabled
- Attributes required: One dual X cable (#3661 1.5M, #3662 3M, #3663 15M) and two (5901/ 5278) dedicated to the single #5887
- For 8205-E6D: (#EJPK)
- Minimum required: 0
- Maximum allowed: 14 (Initial order maximum: 14)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJPL) - Specify mode-4 (1)5901/5278 for EXP24 #5887
Feature indicates that EXP24S SFF Gen2-bay Drawer (#5887) will be configured to Mode 4 (four groups of 6 drive bays) with only one group of 6 drive bays enabled by connecting to one PCIe 3G SAS controller (5901/5278) using one appropriate X cable connecting to only one adapter port. IBM does not provide changes to the mode setting after #5887 is shipped.
- Attributes provided: Designated #5887 configuration in Mode 4 with 6 drive bays enabled
- Attributes required: One dual X cable (#3661 1.5M, #3662 3M, #3663 15M) and one (5901/ 5278) dedicated to the single #5887
- For 8205-E6D: (#EJPL)
- Minimum required: 0
- Maximum allowed: 14 (Initial order maximum: 14)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJPM) - Specify mode-4 (2)5901/5278 for EXP24 #5887
Feature indicates that EXP24S SFF Gen2-bay Drawer (#5887) will be configured to Mode 4 (four groups of 6 drive bays) with two groups of 6 drive bays enabled by connecting to two PCIe 3G SAS controllers (5901/5278) using one appropriate X cable connecting to only one adapter port on each controller. IBM does not provide changes to the mode setting after #5887 is shipped.
- Attributes provided: Designated #5887 configuration in Mode 4 with 12 drive bays enabled
- Attributes required: One dual X cable (#3661 1.5M, #3662 3M, #3663 15M) and two (5901/ 5278) dedicated to the single #5887
- For 8205-E6D: (#EJPM)
- Minimum required: 0
- Maximum allowed: 14 (Initial order maximum: 14)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJPN) - Specify mode-4 (3)5901/5278 for EXP24 #5887
Feature indicates that EXP24S SFF Gen2-bay Drawer (#5887) will be configured to Mode 4 (four groups of 6 drive bays) with three groups of 6 drive bays enabled by connecting to three PCIe 3G SAS controllers (5901/5278) using two appropriate X cables connecting to only one adapter port on each controller. IBM does not provide changes to the mode setting after #5887 is shipped.
- Attributes provided: Designated #5887 configuration in Mode 4 with 18 drive bays enabled
- Attributes required: Two dual X cables (#3661 1.5M, #3662 3M, #3663 15M) and three (5901/ 5278) dedicated to the single #5887
- For 8205-E6D: (#EJPN)
- Minimum required: 0
- Maximum allowed: 14 (Initial order maximum: 14)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJPR) - Specify mode-2 (2)5903/5805 for EXP24 #5887
Feature indicates that EXP24S SFF Gen2-bay Drawer (#5887) will be configured to Mode 2 (two groups of 12 drive bays) with only one group of 12 drive bays enabled by connecting to one pair of PCIe 3G SAS RAID controllers (5903/5805) using one appropriate X cable. IBM does not provide changes to the mode setting after #5887 is shipped.
- Attributes provided: Designated #5887 configuration in Mode 2 with 12 drive bays enabled.
- Attributes required: One dual X cable (#3661 1.5M, #3662 3M, #3663 15M) and two (5903/ 5805) dedicated to the single #5887
- For 8205-E6D: (#EJPR)
- Minimum required: 0
- Maximum allowed: 14 (Initial order maximum: 14)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJPT) - Specify mode-2 (2)5913 for EXP24 #5887
Feature indicates that EXP24S SFF Gen2-bay Drawer (#5887) will be configured to Mode 2 (two groups of 12 drive bays) with only one group of 12 drive bays enabled by connecting to one pair of PCIe2 1.8GB Cache RAID SAS Adapter Tri-port 6Gb controllers (5913) using one appropriate 6G X cable. IBM does not provide changes to the mode setting after #5887 is shipped.
- Attributes provided: Designated #5887 configuration in Mode 2 with 12 drive bays enabled.
- Attributes required: One 6G dual X cable (#3454 3M or #3455 6M or #3456 10m) and one pair 5913 dedicated to the single #5887
- For 8205-E6D: (#EJPT)
- Minimum required: 0
- Maximum allowed: 14 (Initial order maximum: 14)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJPY) - Specify Left Half 12X I/O Drawer to ESA1/ESA2
Directs manufacturing to connect the left half of 12X I/O Drawer (#5802 or /#5803) to port on PCIe2 RAID SAS Adapter (#ESA1 or #ESA2). This eConfig assigned feature helps IBM Manufacturing understand what to build/configure/cable in the absence of Customer Specified Placement (CSP) information. "Left" is defined as the SAS bays seen by a person facing the front of the rack.
- Attributes provided: Connect a port on PCIe2 RAID SAS Adapter to the left half of 12X I/O Drawer PCIe (#5802 or #5803).
- Attributes required: A #ESA1 or #ESA2 and #5802 or #5803
- For 8205-E6D: (#EJPY)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJPZ) - Specify Right Half 12X I/O Drawer to ESA1/ESA2
Directs manufacturing to connect the right half of 12X I/O Drawer (#5802 or /#5803) to port on PCIe2 RAID SAS Adapter (#ESA1 or #ESA2). This eConfig assigned feature helps IBM Manufacturing understand what to build/configure/cable in the absence of Customer Specified Placement (CSP) information. "Right" is defined as the SAS bays seen by a person facing the front of the rack.
- Attributes provided: Connect a port on PCIe2 RAID SAS Adapter to the right half of 12X I/ O Drawer PCIe (#5802 or #5803).
- Attributes required: One #5802 or #5803 and one #ESA1 or #ESA2
- For 8205-E6D: (#EJPZ)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJR1) - Specify Mode-1 1(1)EJ0J/EJ0M/EL3B for EXP24S (#5887/EL1S)
This feature does not order or ship any hardware, but indicates to IBM config tools and to IBM Manufacturing that in this configuration one EXP24S SFF Gen2-bay Drawer (#5887/#EL1S) should be configured in Mode 1 and be using one PCIe3 RAID SAS adapter (#EJ0J/EJ0M/EL3B ) and one 6G YO SAS Cable.
- Attributes provided: Communicate configuration information to IBM Manufacturing
- Attributes required: EXP24S Drawer, one PCIe3 RAID SAS adapter, one SAS YO cable
- For 8205-E6D: (#EJR1)
- Minimum required: 0
- Maximum allowed: 14 (Initial order maximum: 14)
- OS level required:
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: Does not apply
(#EJR2) - Specify Mode-1 1(2)EJ0J/EJ0M/EL3B for EXP24S (#5887/EL1S)
This feature does not order or ship any hardware, but indicates to IBM config tools and to IBM Manufacturing that in this configuration one EXP24S SFF Gen2-bay Drawer (#5887/#EL1S) should be configured in Mode 1 and be using two (one pair) PCIe3 RAID SAS adapters (#EJ0J/EJ0M/EL3B) and two 6G YO SAS Cables.
- Attributes provided: Communicate configuration information to IBM Manufacturing
- Attributes required: EXP24S Drawer, two PCIe3 RAID SAS adapters, two SAS YO cables
- For 8205-E6D: (#EJR2)
- Minimum required: 0
- Maximum allowed: 14 (Initial order maximum: 14)
- OS level required:
- AIX V7.1 with the 7100-03 Technology Level and Service Pack 1 or later
- AIX V6.1 with the 6100-09 Technology Level and Service Pack 1 or later
- IBM i 6.1 with machine code 6.1.1 or late
- IBM i 7.1 or later
- Red Hat Enterprise Linux 6.4 for POWER, or later
- SUSE Linux Enterprise Server 11 Service Pack 3, or later
- Linux users should update to the latest iprutils package available here:
- http://www14.software.ibm.com/support/customercare/sa s/f/lopdiags/home.html
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJR3) Specify Mode-2 1(2)EJ0J/EJ0M/EL3B 1(2) X for EXP24S (#5887/EL1S)
This feature does not order or ship any hardware, but indicates to IBM config tools and to IBM Manufacturing that in this configuration one EXP24S SFF Gen2-bay Drawer (#5887/#EL1S) should be configured in Mode 2 and be using two (one pair) RAID PCIe3 SAS adapters (#EJ0J/EJ0M/EL3B) and two 6G X SAS Cables.
- Attributes provided: Communicate configuration information to IBM Manufacturing
- Attributes required: EXP24S Drawer, two PCIe3 RAID SAS adapters, two SAS X cables
- For 8205-E6D: (#EJR3)
- Minimum required: 0
- Maximum allowed: 14 (Initial order maximum: 14)
- OS level required:
- AIX V7.1 with the 7100-03 Technology Level and Service Pack 1 or later
- AIX V6.1 with the 6100-09 Technology Level and Service Pack 1 or later
- IBM i -not supported
- Red Hat Enterprise Linux 6.4 for POWER, or later
- SUSE Linux Enterprise Server 11 Service Pack 3, or later
- Linux users should update to the latest iprutils package available here:
- http://www14.software.ibm.com/support/customercare/sa s/f/lopdiags/home.html
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJR4) - Specify Mode-2 1(4)EJ0J/EJ0M/EL3B for EXP24S (#5887/EL1S)
This feature does not order or ship any hardware, but indicates to IBM config tools and to IBM Manufacturing that in this configuration one EXP24S SFF Gen2-bay Drawer (#5887/#EL1S) should be configured in Mode 2 and be using four (two pair) PCIe3 RAID SAS adapters (#EJ0J/EJ0M/EL3B) and two 6G X SAS Cables.
- Attributes provided: Communicate configuration information to IBM Manufacturing
- Attributes required: EXP24S Drawer, four PCIe3 RAID SAS adapters, two SAS X cables
- For 8205-E6D: (#EJR4)
- Minimum required: 0
- Maximum allowed: 12 (Initial order maximum: 12)
- OS level required:
- AIX V7.1 with the 7100-03 Technology Level and Service Pack 1 or later
- AIX V6.1 with the 6100-09 Technology Level and Service Pack 1 or later
- IBM i - not supported
- Red Hat Enterprise Linux 6.4 for POWER, or later
- SUSE Linux Enterprise Server 11 Service Pack 3, or later
- Linux users should update to the latest iprutils package available here:
- http://www14.software.ibm.com/support/customercare/sa s/f/lopdiags/home.html
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJR5) - Specify Mode-4 1(4)EJ0J/EJ0M/EL3B for EXP24S (#5887/EL1S)
This feature does not order or ship any hardware, but indicates to IBM config tools and to IBM Manufacturing that in this configuration one EXP24S SFF Gen2-bay Drawer (#5887/#EL1S) should be configured in Mode 4 and be using four (unpaired) PCIe3 RAID SAS adapters (#EJ0J/EJ0M/EL3B) and two 6G X SAS Cables.
- Attributes provided: Communicate configuration information to IBM Manufacturing
- Attributes required: EXP24S Drawer, four PCIe3 RAID SAS adapters, two SAS X cables
- For 8205-E6D: (#EJR5)
- Minimum required: 0
- Maximum allowed: 12 (Initial order maximum: 12)
- OS level required:
- AIX V7.1 with the 7100-03 Technology Level and Service Pack 1 or later
- AIX V6.1 with the 6100-09 Technology Level and Service Pack 1 or later
- IBM i - not supported
- Red Hat Enterprise Linux 6.4 for POWER, or later
- SUSE Linux Enterprise Server 11 Service Pack 3, or later
- Linux users should update to the latest iprutils package available here:
- http://www14.software.ibm.com/support/customercare/sa s/f/lopdiags/home.html
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJR6) Specify Mode-2 1(1)EJ0J/EJ0M/EL3B 1(2) YO for EXP24S (#5887/EL1S)
This feature does not order or ship any hardware, but indicates to IBM config tools and to IBM Manufacturing that in this configuration one EXP24S SFF Gen2-bay Drawer (#5887/#EL1S) should be configured in Mode 2 and be using one PCIe3 RAID SAS adapter (#EJ0J/EJ0M/EL3B) and two 6G YO SAS Cables.
- Attributes provided: Communicate configuration information to IBM Manufacturing
- Attributes required: EXP24S Drawe, one PCIe3 RAID SAS adapter,two SAS YO cables
- For 8205-E6D: (#EJR6)
- Minimum required: 0
- Maximum allowed: 14 (Initial order maximum: 14)
- OS level required:
- AIX V7.1 with the 7100-03 Technology Level and Service Pack 1 or later
- AIX V6.1 with the 6100-09 Technology Level and Service Pack 1 or later
- IBM i - not supported
- Red Hat Enterprise Linux 6.4 for POWER, or later
- SUSE Linux Enterprise Server 11 Service Pack 3, or later
- Linux users should update to the latest iprutils package available here:
- http://www14.software.ibm.com/support/customercare/sa s/f/lopdiags/home.html
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJR7) Specify Mode-2 1(2)EJ0J/EJ0M/EL3B 1(2) YO for EXP24S (#5887/EL1S)
This feature does not order or ship any hardware, but indicates to IBM config tools and to IBM Manufacturing that in this configuration one EXP24S SFF Gen2-bay Drawer (#5887/#EL1S) should be configured in Mode 2 and be using two (nonpaired) PCIe3 RAID SAS adapters (#EJ0J/EJ0M/EL3B) and two 6G YO SAS Cables.
- Attributes provided: Communicate configuration information to IBM Manufacturing
- Attributes required: EXP24S Drawer, two PCIe3 RAID SAS adapters, two SAS YO cables
- For 8205-E6D: (#EJR7)
- Minimum required: 0
- Maximum allowed: 14 (Initial order maximum: 14)
- OS level required:
- AIX V7.1 with the 7100-03 Technology Level and Service Pack 1 or later
- AIX V6.1 with the 6100-09 Technology Level and Service Pack 1 or later
- IBM i - not supported
- Red Hat Enterprise Linux 6.4 for POWER, or later
- SUSE Linux Enterprise Server 11 Service Pack 3, or later
- Linux users should update to the latest iprutils package available here:
- http://www14.software.ibm.com/support/customercare/sa s/f/lopdiags/home.html
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJRA) Specify Mode-2 1(1)EJ0J/EJ0M/EL3B 1(1) YO for EXP24S (#5887/El1S)
This feature does not order or ship any hardware, but indicates to IBM config tools and to IBM Manufacturing that in this configuration one EXP24S SFF Gen2-bay Drawer (#5887/#EL1S) should be configured in Mode 2 and be using one PCIe3 RAID SAS adapter (#EJ0J/EJ0M/EL3B) and one 6G YO SAS Cables. This indicates a "partial" configuration where there are not enough adapters/cables to run all the SAS bays in the EXP24S. If adapters/cables are MES added later to support the rest of the SAS bays, then this specify code should be removed and the appropriate specify feature added to help IBM config tools understand the expanded usage, probably specify feature #EJR7.
- Attributes provided: Communicate configuration information to IBM Manufacturing
- Attributes required: EXP24S Drawer, one PCIe3 RAID SAS Adapter, one 6G YO SAS cable
- For 8205-E6D: (#EJRA)
- Minimum required: 0
- Maximum allowed: 14 (Initial order maximum: 14)
- OS level required:
- AIX V7.1 with the 7100-03 Technology Level and Service Pack 1 or later
- AIX V6.1 with the 6100-09 Technology Level and Service Pack 1 or later
- IBM i - not supported
- Red Hat Enterprise Linux 6.4 for POWER, or later
- SUSE Linux Enterprise Server 11 Service Pack 3, or later
- Linux users should update to the latest iprutils package available here:
- http://www14.software.ibm.com/support/customercare/sa s/f/lopdiags/home.html
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJRB) Specify Mode-2 1(2)EJ0J/EJ0M/EL3B 1(1) X for EXP24S (#5887/EL1S)
This feature does not order or ship any hardware, but indicates to IBM config tools and to IBM Manufacturing that in this configuration one EXP24S SFF Gen2-bay Drawer (#5887/#EL1S) should be configured in Mode 2 and be using two PCIe3 RAID SAS adapters (#EJ0J/EJ0M/EL3B) and one 6G X SAS Cable.
This indicates a "partial" configuration where there are not enough adapters/cables to run all the SAS bays in the EXP24S. If adapters/cables are MES added later to support the rest of the SAS bays, then this specify code should be removed and the appropriate specify feature added to help IBM config tools understand the expanded usage, probably specify feature #EJR4.
- Attributes provided: Communicate configuration information to IBM Manufacturing
- Attributes required: EXP24S Drawer, two PCIe3 RAID SAS Adapters, one 6G X SAS cable
- For 8205-E6D: (#EJRB)
- Minimum required: 0
- Maximum allowed: 14 (Initial order maximum: 14)
- OS level required:
- AIX V7.1 with the 7100-03 Technology Level and Service Pack 1 or later
- AIX V6.1 with the 6100-09 Technology Level and Service Pack 1 or later
- IBM i - not supported
- Red Hat Enterprise Linux 6.4 for POWER, or later
- SUSE Linux Enterprise Server 11 Service Pack 3, or later
- Linux users should update to the latest iprutils package available here:
- http://www14.software.ibm.com/support/customercare/sa s/f/lopdiags/home.html
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJRC) - Specify Mode-4 1(1)EJ0J/EJ0M/EL3B for EXP24S (#5887/EL1S)
This feature does not order or ship any hardware, but indicates to IBM config tools and to IBM Manufacturing that in this configuration one EXP24S SFF Gen2-bay Drawer (#5887/#EL1S) should be configured in Mode 4 and be using one PCIe3 RAID SAS adapter (#EJ0J/EJ0M/EL3B) and one 6G X SAS Cables. One leg of the X cable is left unattached at the adapter end.
This indicates a "partial" configuration where there are not enough adapters/cables to run all the SAS bays in the EXP24S. If adapters/cables are MES added later to support the rest of the SAS bays, then this specify code should be removed and the appropriate specify feature added to help IBM config tools understand the expanded usage, probably specify feature #EJR5, #EJRD or #EJRE.
- Attributes provided: Communicate configuration information to IBM Manufacturing
- Attributes required: EXP24S Drawer, one PCIe3 RAID SAS Adapter, one 6G X SAS cable
- For 8205-E6D: (#EJRC)
- Minimum required: 0
- Maximum allowed: 14 (Initial order maximum: 14)
- OS level required:
- AIX V7.1 with the 7100-03 Technology Level and Service Pack 1 or later
- AIX V6.1 with the 6100-09 Technology Level and Service Pack 1 or later
- IBM i - not supported
- Red Hat Enterprise Linux 6.4 for POWER, or later
- SUSE Linux Enterprise Server 11 Service Pack 3, or later
- Linux users should update to the latest iprutils package available here:
- http://www14.software.ibm.com/support/customercare/sa s/f/lopdiags/home.html
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJRD) - Specify Mode-4 1(2)EJ0J/EJ0M/EL3B for EXP24S (#5887/EL1S)
This feature does not order or ship any hardware, but indicates to IBM config tools and to IBM Manufacturing that in this configuration one EXP24S SFF Gen2-bay Drawer (#5887/#EL1S) should be configured in Mode 4 and be using two (nonpaired) PCIe RAID SAS adapters (#EJ0J/EJ0M/EL3B) and one 6G X SAS Cables.
This indicates a "partial" configuration where there are not enough adapters/cables to run all the SAS bays in the EXP24S. If adapters/cables are MES added later to support the rest of the SAS bays, then this specify code should be removed and the appropriate specify feature added to help IBM config tools understand the expanded usage, probably specify feature #EJR5 or #EJRE.
- Attributes provided: Communicate configuration information to IBM Manufacturing
- Attributes required: EXP24S Drawer, two PCIe3 RAID SAS Adapters, one 6G X SAS cable
- For 8205-E6D: (#EJRD)
- Minimum required: 0
- Maximum allowed: 14 (Initial order maximum: 14)
- OS level required:
- AIX V7.1 with the 7100-03 Technology Level and Service Pack 1 or later
- AIX V6.1 with the 6100-09 Technology Level and Service Pack 1 or later
- IBM i - not supported
- Red Hat Enterprise Linux 6.4 for POWER, or later
- SUSE Linux Enterprise Server 11 Service Pack 3, or later
- Linux users should update to the latest iprutils package available here:
- http://www14.software.ibm.com/support/customercare/sa s/f/lopdiags/home.html
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJRE) - Specify Mode-4 1(3)EJ0J/EJ0M/EL3B for EXP24S (#5888/EL1S)
This feature does not order or ship any hardware, but indicates to IBM config tools and to IBM Manufacturing that in this configuration one EXP24S SFF Gen2-bay Drawer (#5887/#EL1S) should be configured in Mode 4 and be using three (nonpaired) PCIe3 RAID SAS adapter (#EJ0J/EJ0M/EL3B) and two 6G X SAS Cables. One leg of one X cable is left unattached at the adapter end.
This indicates a "partial" configuration where there are not enough adapters/cables to run all the SAS bays in the EXP24S. If adapters/cables are MES added later to support the rest of the SAS bays, then this specify code should be removed and the appropriate specify feature added to help IBM config tools understand the expanded usage, probably specify feature #EJR5.
- Attributes provided: Communicate configuration information to IBM Manufacturing
- Attributes required: EXP24S Drawer, three PCIe3 RAID SAS Adapters, two 6G X SAS cables
- For 8205-E6D: (#EJRE)
- Minimum required: 0
- Maximum allowed: 14 (Initial order maximum: 14)
- OS level required:
- AIX V7.1 with the 7100-03 Technology Level and Service Pack 1 or later
- AIX V6.1 with the 6100-09 Technology Level and Service Pack 1 or later
- IBM i - not supported
- Red Hat Enterprise Linux 6.4 for POWER, or later
- SUSE Linux Enterprise Server 11 Service Pack 3, or later
- Linux users should update to the latest iprutils package available here:
- http://www14.software.ibm.com/support/customercare/sa s/f/lopdiags/home.html
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJRP) - Specify Mode-1 1(2)EJ0L for EXP24S (#5887/EL1S)
This feature does not order or ship any hardware, but indicates to IBM config tools and to IBM Manufacturing that in this configuration one EXP24S SFF Gen2-bay Drawer (#5887/#EL1S) should be configured in Mode 1 and be using two PCIe3 12GB Cache RAID SAS adapters (#EJ0L) and two 6G YO SAS Cables.
- Attributes provided: Communicate configuration information to IBM Manufacturing
- Attributes required: EXP24S Drawer, two PCIe3 12GB Cache SAS RAID adapters, two SAS YO cables
- For 8205-E6D: (#EJRP)
- Minimum required: 0
- Maximum allowed: 14 (Initial order maximum: 14)
- OS level required:
- AIX V7.1 with the 7100-03 Technology Level and Service Pack 1 or later
- AIX V6.1 with the 6100-09 Technology Level and Service Pack 1 or later
- IBM i - not supported
- Red Hat Enterprise Linux 6.4 for POWER, or later
- SUSE Linux Enterprise Server 11 Service Pack 3, or later
- Linux users should update to the latest iprutils package available here:
- http://www14.software.ibm.com/support/customercare/sa s/f/lopdiags/home.html
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJRR) - Specify mode-2 1(4) EJ0L for EXP24S #5887/EL1S
Specify feature EJRR (Specify mode-2 1(4 )EJ0L for EXP24S #5887 or #EL1S) directs manufacturing to configure SFF drawer to mode 2 (two sets of 12 SFF bays) and four PCIe2 12GB Cache RAID SAS Adapter Quad-port 6Gb. Select #EJ0L and two appropriate length HD narrow X cable (#ECBJ -#ECBM). Include two AA cables (#ECCO - #ECC4) between each pair of SAS adapters (total of 4 AA cables). Note: IBM does not provide changes to the mode setting after #5887 or #EL1S is shipped.
- Attributes provided: Configure #5887/EL1S in Mode 2
- Attributes required: Two dual X cables, four AA cables and one port on each of four #EJ0Ls dedicated to the single #5887/EL1S.
- For 8205-E6D: (#EJRR)
- Minimum required: 0
- Maximum allowed: 14 (Initial order maximum: 14)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: Does not apply
(#EJRS) Specify Mode-2 1(2)EJ0L 1(2) X for EXP24S (#5887/EL1S)
This feature does not order or ship any hardware, but indicates to IBM config tools and to IBM Manufacturing that in this configuration one EXP24S SFF Gen2-bay Drawer (#5887/#EL1S) should be configured in Mode 2 and be using two PCIe3 12GB RAID SAS adapters (#EJ0L) and two 6G X SAS Cables.
- Attributes provided: Communicate configuration information to IBM Manufacturing
- Attributes required: EXP24S Drawer, two PCIe3 12GB Cache SAS RAID adapters, two SAS X cables
- For 8205-E6D: (#EJRS)
- Minimum required: 0
- Maximum allowed: 14 (Initial order maximum: 14)
- OS level required:
- AIX V7.1 with the 7100-03 Technology Level and Service Pack 1 or later
- AIX V6.1 with the 6100-09 Technology Level and Service Pack 1 or later
- IBM i - not supported
- Red Hat Enterprise Linux 6.4 for POWER, or later
- SUSE Linux Enterprise Server 11 Service Pack 3, or later
- Linux users should update to the latest iprutils package available here:
- http://www14.software.ibm.com/support/customercare/sa s/f/lopdiags/home.html
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJRT) Specify Mode-2 1(2)EJ0L 1(1) X for EXP24S (#5887/EL1S)
This feature does not order or ship any hardware, but indicates to IBM config tools and to IBM Manufacturing that in this configuration one EXP24S SFF Gen2-bay Drawer (#5887/#EL1S) should be configured in Mode 2 and be using two 12GB Cache RAID SAS adapters (#EJ0L ) and one 6G X SAS Cable.
This indicates a "partial" configuration where there are not enough adapters/cables to run all the SAS bays in the EXP24S. If adapters/cables are MES added later to support the rest of the SAS bays, then this specify code should be removed and the appropriate specify feature added to help IBM config tools understand the expanded usage.
- Attributes provided: Communicate configuration information to IBM Manufacturing
- Attributes required: EXP24S Drawer, two PCIe3 12GB Cache SAS RAID adapters, one SAS X cable
- For 8205-E6D: (#EJRT)
- Minimum required: 0
- Maximum allowed: 14 (Initial order maximum: 14)
- OS level required:
- AIX V7.1 with the 7100-03 Technology Level and Service Pack 1 or later
- AIX V6.1 with the 6100-09 Technology Level and Service Pack 1 or later
- IBM i - not supported
- Red Hat Enterprise Linux 6.4 for POWER, or later
- SUSE Linux Enterprise Server 11 Service Pack 3, or later
- Linux users should update to the latest iprutils package available here:
- http://www14.software.ibm.com/support/customercare/sa s/f/lopdiags/home.html
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJRU) - Non-paired Indicator EJ0L PCIe SAS RAID Adapter
Feature EJRU must be added for every instance of a non-paired SAS RAID adapter #EJ0L. It identifies a specific high availability configuration supported by AIX or Linux which has one #EJ0L on one system and the paired #EJ0L located on a second system. IBM i does not support paired adapter on different servers.
- Attributes provided: SAS RAID adapter firmware disables write cache until a second SAS RAID adapter is recognized.
- Attributes required: Every #EJ0L requires a 6Gb/s SAS RAID adapter (#EJ0L) on both this server and on another server that will pair up the SAS RAID adapter and enable the onboard caches to function.
- For 8205-E6D: (#EJRU)
- Minimum required: 0
- Maximum allowed: 44 (Initial order maximum: 44)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJRW) Specify Left Half 12X I/O Drawer to PCIe3 12GB RAID SAS Adapter
Directs manufacturing to connect the left half of 12X I/O Drawer (such as #5802/EL36 or #5803) to ports on a pair of PCIe3 12GB Cache RAID SAS Adapters (#EJ0L). This eConfig assigned feature helps IBM Manufacturing understand what to build/configure/cable in the absence of Customer Specified Placement (CSP) information. "Left" is defined as the SAS bays seen by a person facing the front of the rack.
- Attributes provided: Communicate placement information to IBM Manufacturing.
- Attributes required: Two PCIe3 12GB Cache SAS RAID Adapters (#EJ0L) and a 12X I/O Drawer (#5802/5803/EL36)
- For 8205-E6D: (#EJRW)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- AIX V7.1 with the 7100-03 Technology Level and Service Pack 1 or later
- AIX V6.1 with the 6100-09 Technology Level and Service Pack 1 or later
- IBM i 6.1 with machine code 6.1.1
- IBM i 7.1 or later
- Red Hat Enterprise Linux 6.4 for POWER, or later
- SUSE Linux Enterprise Server 11 Service Pack 3, or later
- Linux users should update to the latest iprutils package available here:
- http://www14.software.ibm.com/support/customercare/sa s/f/lopdiags/home.html
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJRX) Specify Right Half 12X I/O Drawer to PCIe3 12GB RAID SAS Adapter
Directs manufacturing to connect the right half of 12X I/O Drawer (such as #5802/EL36 or #5803) to ports on a pair of PCIe3 12GB Cache RAID SAS Adapters (#EJ0L). This eConfig assigned feature helps IBM Manufacturing understand what to build/configure/cable in the absence of Customer Specified Placement (CSP) information. "Right" is defined as the SAS bays seen by a person facing the front of the rack.
- Attributes provided: Communicate placement information to IBM Manufacturing.
- Attributes required: Two PCIe3 12GB Cache SAS RAID Adapters (#EJ0L) and a 12X I/O Drawer (#5802/5803/EL36)
- For 8205-E6D: (#EJRX)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- AIX V7.1 with the 7100-03 Technology Level and Service Pack 1 or later
- AIX V6.1 with the 6100-09 Technology Level and Service Pack 1 or later
- IBM i 6.1 with machine code 6.1.1
- IBM i 7.1 or later
- Red Hat Enterprise Linux 6.4 for POWER, or later
- SUSE Linux Enterprise Server 11 Service Pack 3, or later
- Linux users should update to the latest iprutils package available here:
- http://www14.software.ibm.com/support/customercare/sa s/f/lopdiags/home.html
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJRY) - Specify Left Half 12X I/O Drawer to PCIe3 RAID SAS Adapter
Directs manufacturing to connect the left half of 12X I/O Drawer (such as #5802/EL36 or #5803) to PCIe3 RAID SAS Adapter (#EJ0J/EJ0M/EL3B). This eConfig assigned feature helps IBM Manufacturing understand what to build/configure/cable in the absence of Customer Specified Placement (CSP) information. "Left" is defined as the SAS bays seen by a person facing the front of the rack.
- Attributes provided: Communicate placement information to IBM Manufacturing.
- Attributes required: PCIe3 SAS RAID Adapter or adapters (#EJ0J/EJ0M/EL3B) and a 12X I/O Drawer (#5802/5803/EL36)
- For 8205-E6D: (#EJRY)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- AIX V7.1 with the 7100-03 Technology Level and Service Pack 1 or later
- AIX V6.1 with the 6100-09 Technology Level and Service Pack 1 or later
- IBM i 6.1 with machine code 6.1.1
- IBM i 7.1 or later
- Red Hat Enterprise Linux 6.4 for POWER, or later
- SUSE Linux Enterprise Server 11 Service Pack 3, or later
- Linux users should update to the latest iprutils package available here:
- http://www14.software.ibm.com/support/customercare/sa s/f/lopdiags/home.html
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJRZ) - Specify Right Half 12X I/O Drawer to PCIe3 RAID SAS Adapter
Directs manufacturing to connect the right half of 12X I/O Drawer (such as #5802/EL36 or #5803) to PCIe3 RAID SAS Adapters (#EJ0J/EJ0M/EL3B). This eConfig assigned feature helps IBM Manufacturing understand what to build/configure/cable in the absence of Customer Specified Placement (CSP) information. "Right" is defined as the SAS bays seen by a person facing the front of the rack.
- Attributes provided: Communicate placement information to IBM Manufacturing
- Attributes required: PCIe3 SAS RAID Adapter or adapters (#EJ0J/EJ0M/EL3B) and a 12X I/O Drawer (#5802/5803/EL36)
- For 8205-E6D: (#EJRZ)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- AIX V7.1 with the 7100-03 Technology Level and Service Pack 1 or later
- AIX V6.1 with the 6100-09 Technology Level and Service Pack 1 or later
- IBM i 6.1 with machine code 6.1.1
- IBM i 7.1 or later
- Red Hat Enterprise Linux 6.4 for POWER, or later
- SUSE Linux Enterprise Server 11 Service Pack 3, or later
- Linux users should update to the latest iprutils package available here:
- http://www14.software.ibm.com/support/customercare/sa s/f/lopdiags/home.html
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJS1) - Non-paired Indicator ESA3 PCIe SAS RAID Adapter
Feature EJS1 must be added for every instance of a non-paired SAS RAID adapter #ESA3. It identifies a specific high availability configuration supported by AIX or Linux which has one #ESA3 on one system and the paired #ESA3 located on a second system. IBM i does not support paired adapter on different servers.
SAS RAID adapter firmware disables write cache until a second SAS RAID adapter is recognized.
Every #EJS1 requires a 6Gb/s SAS RAID adapter (#ESA3) on both this server and on another server that will pair up the SAS RAID adapter and enable the onboard caches to function.
Limitation
- Cannot be used with #5913
- Cannot be used with #5924
- Attributes provided: SAS RAID adapter firmware disables write cache until a second SAS RAID adapter is recognized.
- Attributes required: Every #ESA3 requires a 6Gb/s SAS RAID adapter CR (#ESA3) on both this server and on another server that will pair up the SAS RAID adapter and enable the onboard caches to function.
- For 8205-E6D: (#EJS1)
- Minimum required: 0
- Maximum allowed: 34 (Initial order maximum: 34)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJS2) - Specify Mode-2 1(2)ESA3 for EXP24S (#5887/#EL1S)
This feature does not order or ship any hardware, but indicates to IBM config tools and to IBM Manufacturing that in this configuration one EXP24S SFF Gen2-bay Drawer (#5887/#EL1S) should be configured in Mode 2 and be using two (one pair) of PCIe2 1.8GB RAID SAS adapter (#ESA3 ) and one X SAS Cable.
This indicates a "partial" configuration where there are not enough adapters/cables to run all the SAS bays in the EXP24S. If additional adapters/cables are MES added later to support the rest of the SAS bays, then this specify code should be removed and the appropriate specify feature added to help IBM config tools understand the expanded usage, probably specify feature #EJS4.
- Attributes provided: Communicate configuration information to IBM Manufacturing
- Attributes required: EXP24S Drawer, two PCIe2 1.8GB Cache RAID SAS Adapters, one X SAS cable
- For 8205-E6D: (#EJS2)
- Minimum required: 0
- Maximum allowed: 14 (Initial order maximum: 14)
- OS level required:
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJS3) - Specify Mode-1 1(2)ESA3 for EXP24S (#5887/#EL1S)
This feature does not order or ship any hardware, but indicates to IBM config tools and to IBM Manufacturing that in this configuration one EXP24S SFF Gen2-bay Drawer (#5887/#EL1S) should be configured in Mode 1 and be using two (one pair) of PCIe2 1.8GB RAID SAS adapter (#ESA3) and two YO SAS Cables.
- Attributes provided: Communicate configuration information to IBM Manufacturing
- Attributes required: EXP24S Drawer, two PCIe2 1.8GB Cache RAID SAS Adapters, two SAS YO cables
- For 8205-E6D: (#EJS3)
- Minimum required: 0
- Maximum allowed: 14 (Initial order maximum: 14)
- OS level required:
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJS4) - Specify Mode-2 1(4)ESA3 for EXP24S (#5887/#EL1S)
This feature does not order or ship any hardware, but indicates to IBM config tools and to IBM Manufacturing that in this configuration one EXP24S SFF Gen2-bay Drawer (#5887/#EL1S) should be configured in Mode 2 and be using four (two pairs) of PCIe2 1.8GB RAID SAS adapters (#ESA3) and two X SAS Cables.
- Attributes provided: Communicate configuration information to IBM Manufacturing
- Attributes required: EXP24S Drawer, four PCIe2 1.8GB Cache SAS RAID Adapters, two SAS X cables
- For 8205-E6D: (#EJS4)
- Minimum required: 0
- Maximum allowed: 8 (Initial order maximum: 8)
- OS level required:
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJS5) Specify Left Half 12X I/O Drawer to PCIe2 1.8GB RAID SAS Adapter
Directs manufacturing to connect the left half of 12X I/O Drawer (#5802/EL36 or #5803) to ports on a pair of PCIe2 1.8GB Cache RAID SAS Adapters (#ESA3). This eConfig assigned feature helps IBM Manufacturing understand what to build/configure/cable in the absence of Customer Specified Placement (CSP) information. "Left" is defined as the SAS bays seen by a person facing the front of the rack.
- Attributes provided: Communicate placement information to IBM Manufacturing.
- Attributes required: Two PCIe2 1.8GB Cache SAS RAID Adapters (#ESA3) and a 12X I/O Drawer (#5802/5803/EL36)
- For 8205-E6D: (#EJS5)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- IBM i 6.1 with machine code 6.1.1
- IBM i 7.1 or later
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EJS6) Specify Right Half 12X I/O Drawer to PCIe2 1.8GB RAID SAS Adapter
Directs manufacturing to connect the right half of 12X I/O Drawer (#5802/EL36 or #5803) to ports on a pair of PCIe2 1.8GB Cache RAID SAS Adapters (#ESA3). This eConfig assigned feature helps IBM Manufacturing understand what to build/configure/cable in the absence of Customer Specified Placement (CSP) information. "Right" is defined as the SAS bays seen by a person facing the front of the rack.
- Attributes provided: Communicate placement information to IBM Manufacturing
- Attributes required: Two PCIe2 1.8GB Cache SAS RAID Adapters (#ESA3) and a 12X I/O Drawer (#5802/5803/EL36)
- For 8205-E6D: (#EJS6)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- IBM i 6.1 with machine code 6.1.1
- IBM i 7.1 or later
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EK51) - Full Width Keyboard -- USB, US English, #103P
(No Longer Available as of October 31, 2017)
This feature provides a USB attached US English #103P business black quiet touch keyboard.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#EK51)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EK52) - Full Width Keyboard -- USB, French, #189
(No Longer Available as of October 31, 2017)
This feature provides a USB attached French #189 business black quiet touch keyboard.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#EK52)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EK53) - Full Width Keyboard -- USB, Italian, #142
(No Longer Available as of October 31, 2017)
This feature provides a USB attached Italian #142 business black quiet touch keyboard.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#EK53)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EK54) - Full Width Keyboard -- USB, German/Austrian, #129
(No Longer Available as of October 31, 2017)
This feature provides a USB attached German/Austrian #129 business black quiet touch keyboard.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#EK54)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EK55) - Full Width Keyboard -- USB, UK English, #166P
(No Longer Available as of October 31, 2017)
This feature provides a USB attached UK English #166 business black quiet touch keyboard.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#EK55)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EK56) - Full Width Keyboard -- USB, Spanish, #172
(No Longer Available as of October 31, 2017)
This feature provides a USB attached Spanish #172 business black quiet touch keyboard.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#EK56)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EK57) - Full Width Keyboard -- USB, Japanese, #194
(No Longer Available as of October 31, 2017)
This feature provides a USB attached Japanese #194P business black quiet touch keyboard.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#EK57)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EK58) - Full Width Keyboard -- USB, Brazilian Portuguese, #275
(No Longer Available as of October 31, 2017)
This feature provides a USB attached Brazilian Portuguese #275 business black quiet touch keyboard.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#EK58)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EK59) - Full Width Keyboard -- USB, Hungarian, #208
(No Longer Available as of October 31, 2017)
This feature provides a USB attached Hungarian #208 business black quiet touch keyboard.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#EK59)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EK60) - Full Width Keyboard -- USB, Korean, #413
(No Longer Available as of October 31, 2017)
This feature provides a USB attached Korean #413 business black quiet touch keyboard.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#EK60)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EK61) - Full Width Keyboard -- USB, Chinese, #467
(No Longer Available as of October 31, 2017)
This feature provides a USB attached Chinese #467 business black quiet touch keyboard.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#EK61)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EK62) - Full Width Keyboard -- USB, French Canadian, #445
(No Longer Available as of October 31, 2017)
This feature provides a USB attached French Canadian #445 business black quiet touch keyboard.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#EK62)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EK64) - Full Width Keyboard -- USB, Belgian/UK, #120
(No Longer Available as of October 31, 2017)
This feature provides a USB attached Belgian/UK #120 business black quiet touch keyboard.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#EK64)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EK65) - Full Width Keyboard -- USB, Swedish/Finnish, #153
(No Longer Available as of October 31, 2017)
This feature provides a USB attached Swedish/Finnish #153 business black quiet touch keyboard.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#EK65)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EK66) - Full Width Keyboard -- USB, Danish, #159
(No Longer Available as of October 31, 2017)
This feature provides a USB attached Danish #159 business black quiet touch keyboard.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#EK66)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EK67) - Full Width Keyboard -- USB, Bulgarian, #442
(No Longer Available as of October 31, 2017)
This feature provides a USB attached Bulgarian #442 business black quiet touch keyboard.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#EK67)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EK68) - Full Width Keyboard -- USB, Swiss/French/German, #150
(No Longer Available as of October 31, 2017)
This feature provides a USB attached Swiss, French/German #150 business black quiet touch keyboard.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#EK68)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EK69) - Full Width Keyboard -- USB, Norwegian,#155
(No Longer Available as of October 31, 2017)
This feature provides a USB attached Norwegian #155 business black quiet touch keyboard.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#EK69)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EK70) - Full Width Keyboard -- USB, Dutch, #143
(No Longer Available as of October 31, 2017)
This feature provides a USB attached Dutch #143 business black quiet touch keyboard.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#EK70)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EK71) - Full Width Keyboard -- USB, Portuguese, #163
(No Longer Available as of October 31, 2017)
This feature provides a USB attached Portuguese #163 business black quiet touch keyboard.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#EK71)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EK72) - Full Width Keyboard -- USB, Greek, #319
(No Longer Available as of October 31, 2017)
This feature provides a USB attached Greek #319 business black quiet touch keyboard.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#EK72)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EK73) - Full Width Keyboard -- USB, Hebrew, #212
(No Longer Available as of October 31, 2017)
This feature provides a USB attached Hebrew #212 business black quiet touch keyboard.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#EK73)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EK74) - Full Width Keyboard -- USB, Polish, #214
(No Longer Available as of October 31, 2017)
This feature provides a USB attached Polish #214 business black quiet touch keyboard.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#EK74)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EK75) - Full Width Keyboard -- USB, Slovakian, #245
(No Longer Available as of October 31, 2017)
This feature provides a USB attached Slovakian #245 business black quiet touch keyboard.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#EK75)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EK76) - Full Width Keyboard -- USB, Czech, #243
(No Longer Available as of October 31, 2017)
This feature provides a USB attached Czech #243 business black quiet touch keyboard.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#EK76)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EK77) - Full Width Keyboard -- USB, Turkish, #179
(No Longer Available as of October 31, 2017)
This feature provides a USB attached Turkish #179 business black quiet touch keyboard.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#EK77)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EK78) - Full Width Keyboard -- USB, LA Spanish, #171
(No Longer Available as of October 31, 2017)
This feature provides a USB attached LA Spanish #171 business black quiet touch keyboard.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#EK78)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EK79) - Full Width Keyboard -- USB, Arabic, #253
(No Longer Available as of October 31, 2017)
This feature provides a USB attached Arabic #253 business black quiet touch keyboard.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#EK79)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EK80) - Full Width Keyboard -- USB, Thai, #191
(No Longer Available as of October 31, 2017)
This feature provides a USB attached Thai #191 business black quiet touch keyboard.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#EK80)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EK81) - Full Width Keyboard -- USB, Russian, #443
(No Longer Available as of October 31, 2017)
This feature provides a USB attached Russian #443 business black quiet touch keyboard.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#EK81)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EK82) - Full Width Keyboard -- USB, Slovenian, #234
(No Longer Available as of October 31, 2017)
This feature provides a USB attached Slovenian #234 business black quiet touch keyboard.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#EK82)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EK83) - Full Width Keyboard -- USB, US English Euro, #103P
(No Longer Available as of October 31, 2017)
This feature provides a USB attached US English EURO #103P business black quiet touch keyboard.
- Attributes provided: Keyboard
- Attributes required: USB Port
- For 8205-E6D: (#EK83)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ELT9) #ES79 Load Source Specify (387GB SFF-2 SSD 5xx for IBM i)
(No longer available as of January 18, 2019)
Specify code indicates a #ES79 solid state drive (SSD) is used as the Load Source.
- Attributes provided: Communicate location of load source to IBM Manufacturing
- Attributes required: #ES79
- For 8205-E6D: (#ELT9)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required:
- IBM i 7.1 TR11 or later
- IBM i 7.2 TR4 or later
- IBM i 7.3 or later
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#ELTF) #ES7F Load Source Specify (775GB SFF-2 SSD 5xx for IBM i)
(No longer available as of January 18, 2019)
Specify code indicates a #ES7F solid state drive (SSD) is used as the Load Source.
- Attributes provided: Communicate location of load source to IBM Manufacturing
- Attributes required: #ES7F
- For 8205-E6D: (#ELTF)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 0)
- OS level required:
- IBM i 7.1 TR11 or later
- IBM i 7.2 TR4 or later
- IBM i 7.3 or later
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#ELB9) - Power 740 AIX Solution Edition
(No Longer Available as of November 30, 2015)
This feature indicates that a configuration has been ordered for the IBM Power 740 that meets the requirements for an AIX Solution Edition.
Note: Feature is not available in the Greater China Group, China-Offshore/on Shore, Hong Kong, Macao, Mongollia and Taiwan, Province of China.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#ELB9)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#ELC0) - PDU Access Cord 0.38m
This 0.38 meter (14 inch) cord is used with a vertically mounted PDU (Power Distribution Unit) such as a #7188 or #7109 when the PDU is located in a 7953-94Y or #ER05 Slim Rack. One end of this power cord connects to the PDU. The other end of this cord connects to the power cord running to the wall outlet or electrical power source.
One PDU Access Cord is required per vertically mounted PDU. Without a PDU Access Cord, inserting and removing the wall outlet power cord into the PDU can be very difficult in the narrow side pockets of the Slim Rack. A PDU Access Cord is not required for PDUs in wider racks such as the 7014-T42 or #0553.
- Attributes provided: Power cord
- Attributes required: None
- For 8202-E4D: (#ELC0)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#ELPM) - Trial PowerVM Live Partition Mobility
This feature will enable a customer to evaluate Live Partition Mobility at no-charge for 60 days. At the conclusion of the trial period clients place an upgrade order for permanent PowerVM Enterprise Edition to maintain continuity. At the end of the trial period (60 days), the client's system will automatically return to PowerVM Standard Edition.
Live Partition Mobility, available only with PowerVM Enterprise Edition, allows for the movement of a running partition from one Power System server to another with no application downtime, resulting in better system utilization, improved application availability, and energy savings. With Live Partition Mobility, planned application downtime due to regular server maintenance can be a thing of the past.
- Attributes provided: A 60-day trial version of PowerVM Enterprise Edition.
- Attributes required: PowerVM Standard Edition and FW 7.3.0, or later.
- For 8205-E6D: (#ELPM)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ELS1) - #ES11 Load Source Specify (387GB SSD SFF-1)
This specify code indicates that a #ES11 Solid State Drive is being used as the Load Source.
- Attributes provided: Communicate location of load source to IBM Manufacturing
- Attributes required: #ES1A
- For 8205-E6D: (#ELS1)
- Minimum required: 1
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: See ES11
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ELS9) - #ES1A Load Source Specify (387GB SSD SFF-2)
This specify code indicates that a #ES1A Solid State Drive is being used as the Load Source.
- Attributes provided: Communicate location of load source to IBM Manufacturing
- Attributes required: #ES11
- For 8205-E6D: (#ELS9)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: See ES1A
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ELSF) - #ES0F Load Source Specify (775GB SSD SFF-1)
This specify code indicates that a #ES0F Solid State Drive is being used as the Load Source.
- Attributes provided: Communicate location of load source to IBM Manufacturing
- Attributes required: #ES0F
- For 8205-E6D: (#ELSF)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 7.1, or later
- IBM i 6.1 with machine code 6.1.1, or later
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ELSH) - #ES0H Load Source Specify (775GB SSD SFF-2)
This specify code indicates that a #ES0H Solid State Drive is being used as the Load Source.
- Attributes provided: Communicate location of load source to IBM Manufacturing
- Attributes required: #ES0H
- For 8205-E6D: (#ELSH)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 6.1 with machine code 6.1.1, or later
- IBM i 7.1, or later
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ELSJ) - #ESDJ Load Source Specify (571GB 15K RPM SFF-1 )
This specify code indicates that a #ESDJ disk drive is being used as the Load Source.
- Attributes provided: Communicate location of load source to IBM Manufacturing
- Attributes required: #ESDJ
- For 8205-E6D: (#ELSJ)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: Same OS requirements as #ESDJ, 571GB 15K RPM SAS SFF-1 for IBM i
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ELSK) - #ES0K Load Source Specify (387GB 1.8" SSD for IBM i)
This specify code indicates that a #ES0K Disk Unit is being used as the Load Source.
- Attributes required: None
- For 8205-E6D: (#ELSK)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- AIX - not supported
- Linux - not supported
- IBM i 7.1 and 7.2 or later supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ELSN) - #ESDN Load Source Specify (571GB 15K RPM SFF-2 )
This specify code indicates that a #ESDN disk drive is being used as the Load Source.
- Attributes provided: Communicate location of load source to IBM Manufacturing
- Attributes required: #ESDN
- For 8205-E6D: (#ELSN)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: IBM i - refer to feature #ESDN
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EM01) - Memory Riser Card
(No Longer Available as of March 31, 2018)
This feature provides a memory riser card with 8 DIMM sockets. One non-featurized memory riser card is in the base system.
- Attributes provided: 8 DIMM sockets
- Attributes required: None
- For 8205-E6D: (#EM01)
- Minimum required: 0
- Maximum allowed: 3 (Initial order maximum: 3)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EM08) - 8GB (2x4GB) Memory DIMMs, 1066 MHz, 2Gb DDR3 DRAM
(No Longer Available as of March 31, 2018)
Provides 8GB of system memory with two 4GB DIMMs.
- Attributes provided: 8GB of system memory
- Attributes required: Two empty memory DIMM slots
- For 8205-E6D: (#EM08)
- Minimum required: 0
- Maximum allowed: 16 (Initial order maximum: 16)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EM4B) - 16GB (2x8GB) Memory DIMMs, 1066 MHz, 4Gb DDR3 DRAM
(No Longer Available as of March 31, 2018)
Provides 16GB of system memory with two 8GB DIMMs.
- Attributes provided: 16GB of system memory
- Attributes required: Two empty memory DIMM slots
- For 8205-E6D: (#EM4B)
- Minimum required: 0
- Maximum allowed: 16 (Initial order maximum: 16)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EM4C) - 32GB (2x16GB) Memory DIMMs, 1066 MHz, 4Gb DDR3 DRAM
(No Longer Available as of March 31, 2018)
Provides 32GB of system memory with two 16GB DIMMs.
- Attributes provided: 32GB of system memory
- Attributes required: Two empty memory DIMM slots
- For 8205-E6D: (#EM4C)
- Minimum required: 0
- Maximum allowed: 16 (Initial order maximum: 16)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EM4D) - 64GB (2x32GB) Memory DIMMs, 1066 MHz, 4Gb DDR3 DRAM
(No Longer Available as of March 31, 2018)
Provides 64GB of system memory with two 32GB DIMMs.
- Attributes provided: 64GB of system memory
- Attributes required: Two empty memory DIMM slots
- For 8205-E6D: (#EM4D)
- Minimum required: 0
- Maximum allowed: 16 (Initial order maximum: 16)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EN01) - 1m (3.3-ft), 10GbE'Net Cable SFP+ Act Twinax Copper
1m (3.3-ft) 10GbE copper SFP+ active twinax Ethernet cables support data transfer rates up to 10 Gb/s. Cable is effective alternative to optical cable for short reach link high-speed connection.
- Attributes provided: 10Gb/s copper SFP+ active twinax Ethernet cable
- Attributes required: One available SFP+ 10Gb/s Ethernet Port on #3700.
- For 8205-E6D: (#EN01)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EN02) - 3m (9.8-ft), 10Gb E'Net Cable SFP+ Act Twinax Copper
3m (9.8-ft) 10GbE copper SFP+ active twinax Ethernet cables support data transfer rates up to 10 Gb/s. Cable is effective alternative to optical cable for short reach link high-speed connection.
- Attributes provided: 10Gb/s copper SFP+ active twinax Ethernet cable
- Attributes required: One available SFP+ 10Gb/s Ethernet Port on #3700.
- For 8205-E6D: (#EN02)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EN03) - 5m (16.4-ft), 10Gb E'Net Cable SFP+ Act Twinax Copper
5m (16.4-ft) 10GbE copper SFP+ active twinax Ethernet cables support data transfer rates up to 10 Gb/s. Cable is effective alternative to optical cable for short reach link high-speed connection.
- Attributes provided: 10Gb/s copper SFP+ active twinax Ethernet cable
- Attributes required: One available SFP+ 10Gb/s Ethernet Port on #3700.
- For 8205-E6D: (#EN03)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EN05) - PCIe x8 Cable 1.5m
(No Longer Available as of August 31, 2017)
This cable connects the EXP30 Ultra SSD I/O Drawer to a GX++ PCIe2 x8 Adapter. Select the length appropriate to your configuration. #EN05 is 1.5m, #EN07 is 3m.
- Attributes provided: PCIe x8 Cable 1.5m
- Attributes required: GX++ 2-port PCIe2 x8 Adapter
- For 8205-E6D: (#EN05)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EN07) - PCIe x8 Cable 3m
(No Longer Available as of August 31, 2017)
This cable connects the EXP30 Ultra SSD I/O Drawer to a GX++ PCIe2 x8 Adapter. Select the length appropriate to your configuration. #EN05 is 1.5m, #EN07 is 3m.
- Attributes provided: PCIe x8 Cable 3m
- Attributes required: GX++ 2-port PCIe2 x8 Adapter
- For 8205-E6D: (#EN07)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EN13) - PCIe 1-port Bisync Adapter
(No Longer Available as of May 13, 2016)
The #EN13 is a full high PCIe adapter which provides 1 RVX port for Bisync capability. This RVX port is labeled "Port 1". Its CCIN = 576C Bisync functionality identical to #2893 PCIe adapter is provided.
Select one of the following cables to attach to port 1 (RVX port):
- #0348 - V.24/EIA232 20-Ft PCI Cable
- #0353 - V.35 20-Ft PCI Cable
- #0359 - X.21 20-Ft PCI Cable
Limitations
- The #2893 does not support the remote ring indicate function.
- There is a second port on the card with an integrated modem, but Bisync is not supported on this port (labeled "Port 0").
- Attributes provided: One full-high PCIe adapter with 1 port for Bisync communications
- Attributes required: PCIe full high slot, external modem, cable for the modem.
- For 8205-E6D: (#EN13)
- Minimum required: 0
- Maximum allowed: 44 (Initial order maximum: 44)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 5 supported in the CEC.
- System maximum of 45 with 5 in the CEC and 40 in 4 x #5802/#5877.
(#EN27) - 2 Port Async EIA-232 PCIe Adapter
(No Longer Available as of March 11, 2016)
Adapter provides connection for 2 asynchronous EIA-232 devices. Ports are programmable to support EIA-232 protocols, at a line speed of 128K bps. Two RJ45 connections are located on the rear of the adapter. To attach to devices using a 9-pin (DB9) connection, use an RJ45-to-DB9 converter. For convenience, one converter is included with this feature. One converter for each connector needing a DB9 connector is needed.
The converter cable shipped with the feature is a 10-pin RJ-45 approximately 30 cm or 1 foot in length. 10-pin is often used for DCE devices like modems. DTE devices may be able to use fewer pin connections. Multiple RJ-45 pin out options are used and sold across the industry. The #3930 feature provides an 8-pin RJ45-to-DB9 converter cable. If an addition 10-pin RJ45-to-DB9 connector like the cable provided with the adapter is desired, it is commonly available from multiple sources and identified as a serial cable with a Digi part number 76000239. It is also possible to look up the cable's pin out specifications and build your own cables.
Note #EN27 and # EN28 are physically and electrically identical adapters, except for the type of PCIe slot used (full-high or low profile).
- Attributes provided: 2-Port Asynchronous EIA-232 via 2x RJ45 connectors, one RJ45-to-DB9 converter cable..
- Attributes required: 1 full high PCIe Slot
- For 8205-E6D: (#EN27)
- Minimum required: 0
- Maximum allowed: 12 (Initial order maximum: 0)
- OS level required:
- AIX Version 7.1 with the 7100-02 Technology Level and Service Pack 2, or later
- AIX Version 6.1 with the 6100-08 Technology Level and Service Pack 2, or later
- AIX Version 6.1 with the 6100-07 Technology Level and Service Pack 7, or later
- IBM i 7.1 or later
- SUSE Linux Enterprise Server 11 Service Pack 2, or later, with current maintenance updates available from SUSE to enable all planned functionality.
- Red Hat Enterprise Linux 6.4 for POWER, or later
- Users should also update their systems with the latest Linux for Power service and productivity tools available at
- http://www.ibm.com/support/customercare/sas/f/lopdiag s/home.html
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EN28) - PCIe LP 2-Port Async EIA-232 Adapter
(No Longer Available as of February 9, 2016)
Adapter provides connection for 2 asynchronous EIA-232 devices. Ports are programmable to support EIA-232 protocols, at a line speed of 128K bps. Two RJ45 connections are located on the rear of the adapter. To attach to devices using a 9-pin (DB9) connection, use an RJ45-to-DB9 converter. For convenience, one converter is included with this feature. One converter for each connector needing a DB9 connector is needed.
The converter cable shipped with the feature is a 10-pin RJ-45 approximately 30 cm or 1 foot in length. 10-pin is often used for DCE devices like modems. DTE devices may be able to use fewer pin connections. Multiple RJ-45 pin out options are used and sold across the industry. The #3930 feature provides an 8-pin RJ45-to-DB9 converter cable. If an addition 10-pin RJ45-to-DB9 connector like the cable provided with the adapter is desired, it is commonly available from multiple sources and identified as a serial cable with a Digi part number 76000239. It is also possible to look up the cable's pin out specifications and build your own cables.
Note #EN27 and #EN28 are physically and electrically identical adapters, except for the type of PICe Slot used (full-high or low profile).
- Attributes provided: 2-Port Asynchronous EIA-232 via 2x RJ45 connectors, one RJ45-to-DB9 converter cable.
- Attributes required: 1 Low Profile (LP) slot
- For 8205-E6D: (#EN28)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 2)
- OS level required:
- AIX Version 7.1 with the 7100-02 Technology Level and Service Pack 2, or later
- AIX Version 6.1 with the 6100-08 Technology Level and Service Pack 2, or later
- AIX Version 6.1 with the 6100-07 Technology Level and Service Pack 7, or later
- IBM i 7.1 or later
- IBM i 7.2 or later
- SUSE Linux Enterprise Server 11 Service Pack 2, or later, with current maintenance updates available from SUSE to enable all planned functionality.
- Red Hat Enterprise Linux 6.4 for POWER, or later
- Users should also update their systems with the latest Linux for Power service and productivity tools available at
- http://www.ibm.com/support/customercare/sas/f/lopdiag s/home.html
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EN29) - 2 Port Async EIA-232 PCIe Adapter
(No Longer Available as of March 31, 2018)
Adapter provides connection for 2 asynchronous EIA-232 devices. Ports are programmable to support EIA-232 protocols, at a line speed of 128K bps. Two RJ45 connections are located on the rear of the adapter. To attach to devices using a 9-pin (DB9) connection, use an RJ45-to-DB9 converter. For convenience, one converter is included with this feature. One converter for each connector needing a DB9 connector is needed.
The converter cable shipped with the feature is a 10-pin RJ-45 approximately 30 cm or 1 foot in length. 10-pin is often used for DCE devices like modems. DTE devices may be able to use fewer pin connections. Multiple RJ-45 pin out options are used and sold across the industry. The #3930 feature provides an 8-pin RJ45-to-DB9 converter cable. If an addition 10-pin RJ45-to-DB9 connector like the cable provided with the adapter is desired, it is commonly available from multiple sources and identified as a serial cable with a Digi part number 76000239. It is also possible to look up the cable's pin out specifications and build your own cables.
This adapter is functionally and electronically equivalent to #EN27 and is functionally equivalent to the earlier #5289 Async adapters.
- Attributes provided: 2-Port Asynchronous EIA-232 via 2x RJ45 connectors, one RJ45-to-DB9 converter cable.
- Attributes required: 1 full high PCIe Slot
- For 8205-E6D: (#EN29)
- Minimum required: 0
- Maximum allowed: 12 (Initial order maximum: 0)
- OS level required:
- AIX - Not supported
- IBM i 7.1 or later
- IBM i 7.2 or later
- IBM i 7.3 or later
- Linux - Not supported
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#EN0A) - PCIe2 16Gb 2-port Fibre Channel Adapter
(No Longer Available as of March 31, 2018)
PCIe Gen3 16 Gigabit dual-port Fibre Channel (FC) Adapter is a high-performance 8x short form adapter also referred to as a PCIe Host Bus Adapter (HBA). The adapter provides two ports of 16Gb Fibre Channel capability using SR optics. Each port can provide up to 16Gb Fibre Channel functions simultaneously. The adapter was initially announced as PCIe Gen2, but upgrades to the adapter firmware and introduction of POWER8 servers have enabled PCIe Gen3.
Each port provides single initiator capability over a fibre link or with NPIV, multiple initiator capability is provided. The ports are SFP+ and include an optical SR transceiver. The ports have LC type connectors and utilize shortwave laser optics. The adapter operates at link speeds of 4, 8 and 16 Gbps and will automatically negotiate to the highest speed possible. LEDs on each port provide information on the status and link speed of the port.
The adapter connects to a Fibre Channel switch at 4Gb, 8Gb or 16Gb. It can directly attach to a device without a switch at 16Gb. Attachment without a switch is not supported at 4Gb or 8Gb.
N_Port ID Virtualization (NPIV) capability is supported through VIOS.
Feature #EN0A and #EN0B are electronically identical. They differ physically only that EN0A has a tail stock for full high PCIe slots and #EN0B has a tail stock for low profile PCIe slots. CCIN is 577F for both features.
Cables are the responsibility of the customer. Use multimode fibre optic cables with short-wave lasers that adhere to the following specifications:
OM4 - multimode 50/125 micron fibre, 4700 MHz*km bandwidth
OM3 - multimode 50/125 micron fibre, 2000 MHz*km bandwidth
OM2 - multimode 50/125 micron fibre, 500 MHz*km bandwidth
OM1 - multimode 62.5/125 micron fibre, 200 MHz*km bandwidth
The maximum cable lengths at the three different link speeds are:
Cable 4 Gbps 8 Gbps 16 Gbps
---------------------------------
OM4 400m 190m 125m
OM3 380m 150m 100m
OM2 150m 50m 35m
OM1 70m 21m 15m
See also optional wrap plug feature #ECW0 which is:
- a) Required to run some diagnostic procedures and
- b) in some cases may speed system boot when placed in empty ports as well as avoid useless messages pointing to a planned empty port.
- Attributes provided: Two 16Gb FC ports (with LC connectors)
- Attributes required: Available PCIe Gen2 slot in supported server
- For 8205-E6D: (#EN0A)
- Minimum required: 0
- Maximum allowed: 5 (Initial order maximum: 5)
- OS level required:
- AIX supported
- IBM i 6.1 supported using VIOS
- IBM i 7.1 TR6 and later using VIOS
- IBM i 7.1 TR8 and later supported with or without VIOS
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Assignment to the VIOS requires either VIOS 2.2.1.6, or later, or VIOS 2.2.2.2, or later
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EN0B) - PCIe2 LP 16Gb 2-port Fibre Channel Adapter
(No Longer Available as of March 31, 2018)
PCIe Gen3 16 Gigabit dual-port Fibre Channel (FC) Adapter is a high-performance 8x short form adapter also referred to as a PCIe Host Bus Adapter (HBA). The adapter provides two ports of 16Gb Fibre Channel capability using SR optics. Each port can provide up to 16Gb Fibre Channel functions simultaneously. The adapter was initially announced as PCIe Gen2, but upgrades to the adapter firmware and introduction of POWER8 servers have enabled PCIe Gen3.
Each port provides single initiator capability over a fibre link or with NPIV, multiple initiator capability is provided. The ports are SFP+ and include an optical SR transceiver. The ports have LC type connectors and utilize shortwave laser optics. The adapter operates at link speeds of 4, 8 and 16 Gbps and will automatically negotiate to the highest speed possible. LEDs on each port provide information on the status and link speed of the port.
The adapter connects to a Fibre Channel switch at 4Gb, 8Gb or 16Gb. It can directly attach to a device without a switch at 16Gb under AIX or VIOS or Linux. Attachment without a switch is not supported at 4Gb or 8Gb.
N_Port ID Virtualization (NPIV) capability is supported through VIOS.
Feature #EN0A and #EN0B are electronically identical. They differ physically only that EN0A has a tail stock for full high PCIe slots and #EN0B has a tail stock for low profile PCIe slots. CCIN is 577F for both features.
Cables are the responsibility of the customer. Use multimode fibre optic cables with short-wave lasers that adhere to the following specifications:
OM4 - multimode 50/125 micron fibre, 4700 MHz*km bandwidth
OM3 - multimode 50/125 micron fibre, 2000 MHz*km bandwidth
OM2 - multimode 50/125 micron fibre, 500 MHz*km bandwidth
OM1 - multimode 62.5/125 micron fibre, 200 MHz*km bandwidth
The maximum cable lengths at the three different link speeds are:
Cable 4 Gbps 8 Gbps 16 Gbps
--------------------------------------
OM4 400m 190m 125m
OM3 380m 150m 100m
OM2 150m 50m 35m
OM1 70m 21m 15m
See also optional wrap plug feature #ECW0 which is:
- a) Required to run some diagnostic procedures and
- b) in some cases may speed system boot when placed in empty ports as well as avoid useless messages pointing to a planned empty port.
- Attributes provided: Two 16Gb FC ports (with LC connectors)
- Attributes required: Available PCIe Gen2 slot in supported server
- For 8205-E6D: (#EN0B)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- AIX supported
- IBM i 6.1 supported using VIOS
- IBM i 7.1 TR6 and later using VIOS
- IBM i 7.1 TR8 and later supported with or without VIOS
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Assignment to the VIOS requires either VIOS 2.2.1.6, or later, or VIOS 2.2.2.2, or later
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EN0H) - PCIe2 4-port (10Gb FCoE & 1GbE) SR&RJ45
(No Longer Available as of March 31, 2018)
This PCIe Gen2 Converged Network Adapter (CNA) supports both Ethernet NIC (Network Interface Card) traffic and Fibre Channel traffic over Ethernet (FCoE). The adapter provides two 10 Gb SR optical ports and two 1 Gb RJ45 ports in a PCIe 8x short form adapter. The 10Gb ports have CNA functionality. The 1Gb ports have Ethernet capability.
NPIV capability is provided through VIOS
The 10Gb ports are SFP+ and include an optical SR transceiver. The ports have LC Duplex type connectors and utilize shortwave laser optics and MMF-850nm fiber cabling. With 62.5 micron OM1, up to 33 meter length fiber cables are supported. With 50 micron OM2, up to 82 meter fiber cable lengths are supported. With 50 micron OM3 or OM4, up to 300 meter fiber cable lengths are supported. Note that an FCoE switch is required for any FCoE traffic.
For the 1Gb RJ45 ports, 4-pair CAT-5 Unshielded Twisted Pair (UTP) cable or higher is supported for distances of up to 100 meters. In addition to 1Gb (1000 Mb) networks, 100 Mb networks are also supported, but 10Mb networks are not supported.
#EN0H and #EN0J adapters are electronically identical. They are physically identical except #EN0H has a tail stock for full high PCIe slots and #EN0J has a tail stock for low profile slots. The CCIN is 2B93 for both features.
Details for the ports include:
- AIX NIM support
- IEEE 802.3ae (10 GbE), 802.3ab (1 GbE), 802.1p priority, 802.1Q VLAN tagging, 802.3x flow control, 802.3ad load-balancing and failover,
- Link aggregation, IEEE 802.3ad 802.3
- Multiple MAC addresses per interface
- MSI-X, MSI and support of legacy pin interrupts
- Ether II and IEEE 802.3 encapsulated frames
- Jumbo frames up to 9.6 Kbytes
- TCP checksum offload for IPv4 and IPv6
- TCP segmentation Offload (TSO) for IPv4 and IPv6
- UDP checksum offload for IPv4 and IPv6
- AIX, IBM i and Linux provide software iSCSI support through the adapter. Linux can also leverage adapter hardware support including initiator and header & data digest (CRC) generation and checking
- Attributes provided: Four ports - two 10Gb CNA and two 1Gb E
- Attributes required: PCIe Gen2 slot
- For 8205-E6D: (#EN0H)
- Minimum required: 0
- Maximum allowed: 5 (Initial order maximum: 5)
- OS level required:
- AIX Version 7.1 with the 7100-02 Technology Level and Service Pack 2, or later
- AIX Version 7.1 with the 7100-01 Technology Level and Service Pack 7, or later
- AIX Version 6.1 with the 6100-08 Technology Level and Service Pack 2, or later
- AIX Version 6.1 with the 6100-07 Technology Level and Service Pack 7, or later (Planned availability March 29, 2013)
- IBM i 6.1 supported -- VIOS required
- IBM i 7.1 supported -- VIOS required
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Assignment to the VIOS requires either VIOS 2.2.1.6, or later, or VIOS 2.2.2.2, or later
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note: IBM i supports Ethernet NIC through VIOS, but does not support the use of FCoE data (with/without VIOS) through this adapter.
(#EN0J) - PCIe2 LP 4-port (10Gb FCoE & 1GbE) SR&RJ45
(No Longer Available as of March 31, 2018)
This PCIe Gen2 Converged Network Adapter (CNA) supports both Ethernet NIC (Network Interface Card) traffic and Fibre Channel traffic over Ethernet (FCoE). The adapter provides two 10 Gb SR optical ports and two 1 Gb RJ45 ports in a PCIe 8x short form adapter. The 10Gb ports have CNA functionality. The 1Gb ports have Ethernet capability.
NPIV capability is provided through VIOS
The 10Gb ports are SFP+ and include an optical SR transceiver. The ports have LC Duplex type connectors and utilize shortwave laser optics and MMF-850nm fiber cabling. With 62.5 micron OM1, up to 33 meter length fiber cables are supported. With 50 micron OM2, up to 82 meter fiber cable lengths are supported. With 50 micron OM3 or OM4, up to 300 meter fiber cable lengths are supported. Note that an FCoE switch is required for any FCoE traffic.
For the 1Gb RJ45 ports, 4-pair CAT-5 Unshielded Twisted Pair (UTP) cable or higher is supported for distances of up to 100 meters. In addition to 1Gb (1000 Mb) networks, 100 Mb networks are also supported, but 10Mb networks are not supported.
#EN0H and #EN0J adapters are electronically identical. They are physically identical except #EN0H has a tail stock for full high PCIe slots and #EN0J has a tail stock for low profile slots. The CCIN is 2B93 for both features.
Details for the ports include:
- AIX NIM support
- IEEE 802.3ae (10 GbE), 802.3ab (1 GbE), 802.1p priority, 802.1Q VLAN tagging, 802.3x flow control, 802.3ad load-balancing and failover,
- Link aggregation, IEEE 802.3ad 802.3
- Multiple MAC addresses per interface
- MSI-X, MSI and support of legacy pin interrupts
- Ether II and IEEE 802.3 encapsulated frames
- Jumbo frames up to 9.6 Kbytes
- TCP checksum offload for IPv4 and IPv6
- TCP segmentation Offload (TSO) for IPv4 and IPv6
- UDP checksum offload for IPv4 and IPv6
- AIX, IBM i and Linux provide software iSCSI support through the adapter. Linux can also leverage adapter hardware support including initiator and header & data digest (CRC) generation and checking
- Attributes provided: Four ports - two 10Gb CNA and two 1Gb E
- Attributes required: PCIe Gen2 slot
- For 8205-E6D: (#EN0J)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- AIX Version 7.1 with the 7100-02 Technology Level and Service Pack 2, or later
- AIX Version 7.1 with the 7100-01 Technology Level and Service Pack 7, or later
- AIX Version 6.1 with the 6100-08 Technology Level and Service Pack 2, or later
- AIX Version 6.1 with the 6100-07 Technology Level and Service Pack 7, or later (Planned availability March 29, 2013)
- IBM i 6.1 supported -- VIOS required
- IBM i 7.1 supported -- VIOS required
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Assignment to the VIOS requires either VIOS 2.2.1.6, or later, or VIOS 2.2.2.2, or later
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note: IBM i supports Ethernet NIC through VIOS, but does not support the use of FCoE data (with/without VIOS) through this adapter.
(#EN0K) - PCIe2 4-port (10Gb FCoE & 1GbE) SFP+Copper&RJ45
(No Longer Available as of March 31, 2018)
This PCIe Gen2 Converged Network Adapter (CNA) supports both Ethernet NIC (Network Interface Card) traffic and Fibre Channel traffic over Ethernet (FCoE). The adapter provides two 10 Gb ports for active copper twinax cables and two 1 Gb RJ45 ports in a PCIe 8x short form adapter. The 10Gb ports have CNA (both NIC and FCoE) functionality. The 1Gb ports have Ethernet capability.
NPIV capability is provided through VIOS
SR-IOV capability for the NIC function is supported on specific servers with the appropriate firmware and OS level for any of the four ports.
The 10Gb ports are SFP+ and do not include a transceiver. Active Copper twinax cables up to 5 meter in length are supported such as provided by feature #EN01, #EN02 or #EN03. A transceiver is included with these cables. Note that SFP+ twinax copper is NOT AS/400 5250 twinax or CX4 or 10 GBase-T. Active cables differ from passive cables. Note that an FCoE switch is required for any FCoE traffic.
For the 1Gb RJ45 ports, 4-pair CAT-5 Unshielded Twisted Pair (UTP) cable or higher is supported for distances of up to 100 meters. In addition to 1Gb (1000 Mb) networks, 100 Mb networks are also supported, but 10Mb networks are not supported.
#EN0K and #EN0L adapters are electronically identical. They are physically identical except #EN0K has a tail stock for full high PCIe slots and #EN0L has a tail stock for low profile slots. The CCIN is 2CC1 for both features.
#EN0K/EN0L are very similar to the #EN0H/#EN0J adapters except the #EN0H/EN0K use SR optical cabling and has a different CCIN.
Details for the ports include:
- AIX NIM support
- IEEE 802.3ae (10 GbE), 802.3ab (1 GbE), 802.1p priority, 802.1Q VLAN tagging, 802.3x flow control, 802.3ad load-balancing and failover,
- Link aggregation, IEEE 802.3ad 802.3
- Multiple MAC addresses per interface
- MSI-X, MSI and support of legacy pin interrupts
- Ether II and IEEE 802.3 encapsulated frames
- Jumbo frames up to 9.6 Kbytes
- TCP checksum offload for IPv4 and IPv6
- TCP segmentation Offload (TSO) for IPv4 and IPv6
- UDP checksum offload for IPv4 and IPv6
- AIX, IBM i and Linux provide software iSCSI support through the adapter. Linux can also leverage adapter hardware support including initiator and header & data digest (CRC) generation and checking
- Attributes provided: Four ports - two 10Gb CNA and two 1Gb E
- Attributes required: PCIe Gen2 or Gen3 slot
- For 8205-E6D: (#EN0K)
- Minimum required: 0
- Maximum allowed: 44 (Initial order maximum: 44)
- OS level required:
- AIX V7.1 with the 7100-03 Technology Level and Service Pack 2 or later
- AIX V6.1 with the 6100-09 Technology Level and Service Pack 2 or later
- IBM i - supported through VIOS
- SUSE Linux Enterprise Server 11 Service Pack 3 for POWER, with current maintenance updates available from SUSE to enable all planned functionality
- Red Hat Enterprise Linux 6.5, for POWER, or later
- Users should also update their systems with the latest Linux for POWER service and productivity tools from the IBM website
- http://www14.software.ibm.com/webapp/set2/sas/f/lopdi ags/home.html
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note: Attachment to the VIOS requires VIOS 2.2.3.2 or later
SR-IOV requires:
- HMC
- AIX V7.1 with the 7100-03 Technology Level and Service Pack 2 or later,
- AIX V6.1 with the 6100-09 Technology Level and Service Pack 2 or later,
- SR-IOV Assigned to the VIOS requires VIOS 2.2.3.2 or later
- SUSE Linux Enterprise Server 11 Service Pack 3 for POWER, with current maintenance updates available from SUSE to enable all planned functionality
- Red Hat Enterprise Linux 6.4, for POWER, or later
(#EN0L) - PCIe2 LP 4-port(10Gb FCoE & 1GbE) SFP+Copper&RJ45
(No Longer Available as of March 31, 2018)
This low profile PCIe Gen2 Converged Network Adapter (CNA) supports both Ethernet NIC (Network Interface Card) traffic and Fibre Channel traffic over Ethernet (FCoE). The adapter provides two 10 Gb ports for active copper twinax cables and two 1 Gb RJ45 ports in a PCIe 8x short form adapter. The 10Gb ports have CNA (both NIC and FCoE) functionality. The 1Gb ports have Ethernet capability. NPIV capability is provided through VIOS SR-IOV capability for the NIC function is supported on specific servers with the appropriate firmware and OS level for any of the four ports. The 10Gb ports are SFP+ and do not include a transceiver. Active Copper twinax cables up to 5 meter in length are supported such as provided by feature #EN01, #EN02 or #EN03. A transceiver is included with these cables. Note that SFP+ twinax copper is NOT AS/400 5250 twinax or CX4 or 10 GBase-T. Active cables differ from passive cables. Note that an FCoE switch is required for any FCoE traffic. For the 1Gb RJ45 ports, 4-pair CAT-5 Unshielded Twisted Pair (UTP) cable or higher is supported for distances of up to 100 meters. In addition to 1Gb (1000 Mb) networks, 100 Mb networks are also supported, but 10Mb networks are not supported. #EN0K and #EN0L adapters are electronically identical. They are physically identical except #EN0K has a tail stock for full high PCIe slots and #EN0L has a tail stock for low profile slots. The CCIN is 2CC1 for both features. #EN0K/EN0L are very similar to the #EN0H/#EN0J adapters except the #EN0H/EN0K use SR optical cabling and has a different CCIN. Details for the ports include:
- AIX NIM support
- IEEE 802.3ae (10 GbE), 802.3ab (1 GbE), 802.1p priority, 802.1Q VLAN tagging, 802.3x flow control, 802.3ad load-balancing and failover,
- Link aggregation, IEEE 802.3ad 802.3
- Multiple MAC addresses per interface
- MSI-X, MSI and support of legacy pin interrupts
- Ether II and IEEE 802.3 encapsulated frames
- Jumbo frames up to 9.6 Kbytes
- TCP checksum offload for IPv4 and IPv6
- TCP segmentation Offload (TSO) for IPv4 and IPv6
- UDP checksum offload for IPv4 and IPv6
- AIX, IBM i and Linux provide software iSCSI support through the adapter. Linux can also leverage adapter hardware support including initiator and header & data digest (CRC) generation and checking
- Attributes provided: Four ports - two 10Gb CNA and two 1Gb E
- Attributes required: PCIe Gen2 or Gen3 slot
- For 8205-E6D: (#EN0L)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- AIX V7.1 with the 7100-03 Technology Level and Service Pack 2 or later
- AIX V6.1 with the 6100-09 Technology Level and Service Pack 2 or later
- SUSE Linux Enterprise Server 11 Service Pack 3 for POWER, with current maintenance updates available from SUSE to enable all planned functionality
- Red Hat Enterprise Linux 6.5, for POWER, or later
- Users should also update their systems with the latest Linux for POWER service and productivity tools from the IBM website
- http://www14.software.ibm.com/webapp/set2/sas/f/lopdi ags/home.html
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note: Attachment to the VIOS requires VIOS 2.2.3.2 or later
(#EN0S) - PCIe2 4-Port (10Gb+1GbE) SR+RJ45 Adapter
(No Longer Available as of March 31, 2018)
PCIe Gen2 x8 short Ethernet adapter supports Ethernet NIC (Network Interface Card) traffic. The adapter provides two 10 Gb SR optical ports and two 1 Gb RJ45 ports in a PCIe 8x short form adapter.
The 10Gb ports are SFP+ and include optical SR transceivers. The ports have LC Duplex type connectors and utilize shortwave laser optics and MMF-850nm fiber cabling. With 62.5 micron OM1, up to 33 meter length fiber cables are supported. With 50 micron OM2, up to 82 meter fiber cable lengths are supported. With 50 micron OM3 or OM4, up to 300 meter fiber cable lengths are supported.
For the 1Gb RJ45 ports, 4-pair CAT-5 Unshielded Twisted Pair (UTP) cable or higher is supported for distances of up to 100 meters. In addition to 1Gb (1000 Mb) networks, 100 Mb networks are also supported, but 10Mb networks are not supported.
#EN0S and #EN0T adapters are electronically identical. They are physically identical except #EN0S has a tail stock for full high PCIe slots and #EN0T has a tail stock for low profile slots. The CCIN is 2CC3 for both features.
Details for the ports include:
- IEEE 802.3ae (10GBASE-SR), IEEE 802.3ab (1000BASE-T GbE), IEEEu 802.3u (100BASE-T), 802.1p priority, 802.1Q VLAN tagging, 802.3x flow control, 802.3ad load-balancing and failover,
- Link aggregation, IEEE 802.3ad 802.3
- Multiple MAC addresses/promiscuous mode (for PowerVM/VIOS) per interface
- Message Signalling Interrupt MSI-X, MSI and support of legacy pin interrupts
- Ether II and IEEE 802.3 encapsulated frames
- Jumbo frames up to 9.6 Kbytes
- TCP checksum offload for IPv4 and IPv6
- TCP segmentation Offload (TSO) RSS (Receive Side Scaling) support for IPv4, IPv6 and UDP for IPv4 and IPv6
- UDP checksum offload for IPv4 and IPv6
- Attributes provided: Four ports - two 10Gb and two 1Gb E
- Attributes required: PCIe Gen2 or Gen3 slot - full high
- For 8205-E6D: (#EN0S)
- Minimum required: 0
- Maximum allowed: 5 (Initial order maximum: 5)
- OS level required:
- AIX Version 6.1 with the 6100-09 Technology Level and Service Pack 3 and APAR IV56366 or later
- AIX Version 7.1 with the 7100-03 Technology Level and Service Pack 3 and APAR IV56367 or later
- AIX Version 7.1 with the 7100-01 Technology Level and Service Pack 10 or later
- AIX Version 7.1 with the 7100-02 Technology Level and Service Pack 5 or later
- AIX Version 6.1 with the 6100-07 Technology Level and service Pack 10 or later
- AIX Version 6.1 with the 6100-08 Technology Level and service Pack 5 or later
- IBM i supported through VIOS
- SUSE Linux Enterprise 11 Service Pack 3, or later with current maintenance updates available from SUSE
- Red Hat Enterprise Linux for POWER V6.5 or later with current maintenance updates available from Red Hat
- Red Hat Enterprise Linux for POWER V7 or later with current maintenance updates available from Red Hat
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Assignment to the VIOS requires
- VIOS 2.2.3.3 with ifix IV56366 or later
- VIOS 2.2.2.5 or later
- VIOS 2.2.1.9 or later
(#EN0T) - PCIe2 LP 4-Port (10Gb+1GbE) SR+RJ45 Adapter
(No Longer Available as of March 31, 2018)
PCIe Gen2 x8 short Ethernet adapter supports Ethernet NIC (Network Interface Card) traffic. The adapter provides two 10 Gb SR optical ports and two 1 Gb RJ45 ports in a PCIe 8x short form adapter.
The 10Gb ports are SFP+ and include optical SR transceivers. The ports have LC Duplex type connectors and utilize shortwave laser optics and MMF-850nm fiber cabling. With 62.5 micron OM1, up to 33 meter length fiber cables are supported. With 50 micron OM2, up to 82 meter fiber cable lengths are supported. With 50 micron OM3 or OM4, up to 300 meter fiber cable lengths are supported.
For the 1Gb RJ45 ports, 4-pair CAT-5 Unshielded Twisted Pair (UTP) cable or higher is supported for distances of up to 100 meters. In addition to 1Gb (1000 Mb) networks, 100 Mb networks are also supported, but 10Mb networks are not supported.
#EN0S and #EN0T adapters are electronically identical. They are physically identical except #EN0S has a tail stock for full high PCIe slots and #EN0T has a tail stock for low profile slots. The CCIN is 2CC3 for both features.
AIX NIM and Linux Network Install are supported.
Details for the ports include:
- IEEE 802.3ae (10GBASE-SR), IEEE 802.3ab (1000BASE-T GbE), IEEEu 802.3u (100BASE-T), 802.1p priority, 802.1Q VLAN tagging, 802.3x flow control, 802.3ad load-balancing and failover,
- Link aggregation, IEEE 802.3ad 802.3
- Multiple MAC addresses/promiscuous mode (for PowerVM/VIOS) per interface
- Message Signalling Interrupt MSI-X, MSI and support of legacy pin interrupts
- Ether II and IEEE 802.3 encapsulated frames
- Jumbo frames up to 9.6 Kbytes
- TCP checksum offload for IPv4 and IPv6
- TCP segmentation Offload (TSO) RSS (Receive Side Scaling) support for IPv4, IPv6 and UDP for IPv4 and IPv6
- UDP checksum offload for IPv4 and IPv6
- AIX, IBM i and Linux provide software iSCSI support through the adapter.
- Attributes provided: Four ports - two 10Gb and two 1Gb E
- Attributes required: PCIe Gen2 or Gen3 slot - low profile
- For 8205-E6D: (#EN0T)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- AIX Version 6.1 with the 6100-09 Technology Level and Service Pack 3 and APAR IV56366 or later
- AIX Version 7.1 with the 7100-03 Technology Level and Service Pack 3 and APAR IV56367 or later
- AIX Version 7.1 with the 7100-01 Technology Level and Service Pack 10 or later
- AIX Version 7.1 with the 7100-02 Technology Level and Service Pack 5 or later
- AIX Version 6.1 with the 6100-07 Technology Level and service Pack 10 or later
- AIX Version 6.1 with the 6100-08 Technology Level and service Pack 5 or later
- IBM i supported through VIOS
- SUSE Linux Enterprise 11 Service Pack 3, or later with current maintenance updates available from SUSE
- Red Hat Enterprise Linux for POWER V6.5 or later with current maintenance updates available from Red Hat
- Red Hat Enterprise Linux for POWER V7 or later with current maintenance updates available from Red Hat
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Assignment to the VIOS requires
- VIOS 2.2.3.3 with ifix IV56366 or later
- VIOS 2.2.2.5 or later
- VIOS 2.2.1.9 or later
(#EN0U) - PCIe2 4-port (10Gb+1GbE) Copper SFP+RJ45 Adapter
(No Longer Available as of March 31, 2018)
PCIe Gen2 x8 short Ethernet adapter supports Ethernet NIC (Network Interface Card) traffic. The adapter provides two 10 Gb twinax copperl ports and two 1 Gb RJ45 ports in a PCIe 8x short form adapter.
The 10Gb ports are SFP+ and do not include a transceiver. Active Copper twinax cables up to 5 meter in length are supported such as provided by feature #EN01, #EN02 or #EN03. A transceiver is included with these cables. Note that SFP+ twinax copper is NOT AS/400 5250 twinax or CX4 or 10 GBase-T. Active cables differ from passive cables.
For the 1Gb RJ45 ports, 4-pair CAT-5 Unshielded Twisted Pair (UTP) cable or higher is supported for distances of up to 100 meters. In addition to 1Gb (1000 Mb) networks, 100 Mb networks are also supported, but 10Mb networks are not supported.
#EN0U and #EN0V adapters are electronically identical. They are physically identical except #EN0U has a tail stock for full high PCIe slots and #EN0V has a tail stock for low profile slots. The CCIN is 2CC3 for both features.
Details for the ports include:
- AIX NIM and Linux Network Install are supported.
- IEEE 802.3ae (10 GbE),IEEE 802.3ab (1000BASE-T GbE), 100BASE-T IEEEu, 802.1p priority, 802.1Q VLAN tagging, 802.3x flow control, 802.3ad load-balancing and failover,
- Link aggregation, IEEE 802.3ad 802.3
- Multiple MAC addresses/promiscuous mode (for PowerVM/VIOS) per interface
- Message Signalling Interrupt MSI-X, MSI and support of legacy pin interrupts
- Ether II and IEEE 802.3 encapsulated frames
- Jumbo frames up to 9.6 Kbytes
- TCP checksum offload for IPv4 and IPv6
- TCP segmentation Offload (TSO) for IPv4 and IPv6
- UDP checksum offload for IPv4 and IPv6
- AIX, IBM i and Linux provide software iSCSI support through the adapter.
- Attributes provided: Four ports - two 10Gb and two 1Gb E
- Attributes required: PCIe Gen2 or Gen3 slot - full high
- For 8205-E6D: (#EN0U)
- Minimum required: 0
- Maximum allowed: 5 (Initial order maximum: 5)
- OS level required:
- AIX Version 6.1 with the 6100-09 Technology Level and Service Pack 3 and APAR IV56366 or later
- AIX Version 7.1 with the 7100-03 Technology Level and Service Pack 3 and APAR IV56367 or later
- AIX Version 7.1 with the 7100-01 Technology Level and Service Pack 10 or later
- AIX Version 7.1 with the 7100-02 Technology Level and Service Pack 5 or later
- AIX Version 6.1 with the 6100-07 Technology Level and service Pack 10 or later
- AIX Version 6.1 with the 6100-08 Technology Level and service Pack 5 or later
- IBM i supported through VIOS
- SUSE Linux Enterprise 11 Service Pack 3, or later with current maintenance updates available from SUSE
- Red Hat Enterprise Linux for POWER V6.5 or later with current maintenance updates available from Red Hat
- Red Hat Enterprise Linux for POWER V7 or later with current maintenance updates available from Red Hat
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Assignment to the VIOS requires
- VIOS 2.2.3.3 with ifix IV56366 or later
- VIOS 2.2.2.5 or later
- VIOS 2.2.1.9 or later
(#EN0V) - PCIe2 LP 4-port (10Gb+1GbE) Copper SFP+RJ45 Adapter
(No Longer Available as of March 31, 2018)
PCIe Gen2 x8 short Ethernet adapter supports Ethernet NIC (Network Interface Card) traffic. The adapter provides two 10 Gb twinax copperl ports and two 1 Gb RJ45 ports in a PCIe 8x short form adapter.
The 10Gb ports are SFP+ and do not include a transceiver. Active Copper twinax cables up to 5 meter in length are supported such as provided by feature #EN01, #EN02 or #EN03. A transceiver is included with these cables. Note that SFP+ twinax copper is NOT AS/400 5250 twinax or CX4 or 10 GBase-T. Active cables differ from passive cables.
For the 1Gb RJ45 ports, 4-pair CAT-5 Unshielded Twisted Pair (UTP) cable or higher is supported for distances of up to 100 meters. In addition to 1Gb (1000 Mb) networks, 100 Mb networks are also supported, but 10Mb networks are not supported.
#EN0U and #EN0V adapters are electronically identical. They are physically identical except #EN0U has a tail stock for full high PCIe slots and #EN0V has a tail stock for low profile slots. The CCIN is 2CC3 for both features.
AIX NIM and Linux Network Install are supported.
Details for the ports include:
- IEEE 802.3ae (10 GbE),IEEE 802.3ab (1000BASE-T GbE), 100BASE-T IEEEu, 802.1p priority, 802.1Q VLAN tagging, 802.3x flow control, 802.3ad load-balancing and failover,
- Link aggregation, IEEE 802.3ad 802.3
- Multiple MAC addresses/promiscuous mode (for PowerVM/VIOS) per interface
- Message Signalling Interrupt MSI-X, MSI and support of legacy pin interrupts
- Ether II and IEEE 802.3 encapsulated frames
- Jumbo frames up to 9.6 Kbytes
- TCP checksum offload for IPv4 and IPv6
- TCP segmentation Offload (TSO) for IPv4 and IPv6
- UDP checksum offload for IPv4 and IPv6
- AIX, IBM i and Linux provide software iSCSI support through the adapter.
- Attributes provided: Four ports - two 10Gb and two 1Gb E
- Attributes required: PCIe Gen2 or Gen3 slot - low profile
- For 8205-E6D: (#EN0V)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- AIX Version 6.1 with the 6100-09 Technology Level and Service Pack 3 and APAR IV56366 or later
- AIX Version 7.1 with the 7100-03 Technology Level and Service Pack 3 and APAR IV56367 or later
- AIX Version 7.1 with the 7100-01 Technology Level and Service Pack 10 or later
- AIX Version 7.1 with the 7100-02 Technology Level and Service Pack 5 or later
- AIX Version 6.1 with the 6100-07 Technology Level and service Pack 10 or later
- AIX Version 6.1 with the 6100-08 Technology Level and service Pack 5 or later
- IBM i supported through VIOS
- SUSE Linux Enterprise 11 Service Pack 3, or later with current maintenance updates available from SUSE
- Red Hat Enterprise Linux for POWER V6.5 or later with current maintenance updates available from Red Hat
- Red Hat Enterprise Linux for POWER V7 or later with current maintenance updates available from Red Hat
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Assignment to the VIOS requires
- VIOS 2.2.3.3 with ifix IV56366 or later
- VIOS 2.2.2.5 or later
- VIOS 2.2.1.9 or later
(#EN0W) - PCIe2 2-port 10/1GbE BaseT RJ45 Adapter
(No Longer Available as of March 31, 2018)
PCIe Gen2 short x8 adapter which provides two 10G-BaseT ports. The ports are RJ45. The ports default to auto negotiate the highest speed either 10Gb (10GBaseT), 1Gb (1000BaseT) or 100Mb (100BaseT) full duplex. Each RJ45 port's configuration is independent of the other. The adapter supports Ethernet NIC (Network Interface Card) traffic.
The RJ45 ports use 4-pair CAT-6A cabling for distances of up to 100 meters or CAT-6 cabling for distances up to 37 meters. CAT5 cabling is not tested and is not supported.
#EN0W and #EN0X are electronically identical with the same CCIN of 2CC4. #EN0W has a full high tail stock and #EN0X has a low profile tail stock.
Details for the ports include:
- AIX NIM and Linux Network Install are supported.
- IEEE 802.3an (10GBASE-T), IEEE 802.3ab (1000BASE-T GbE), IEEEu (100BASE-T), 802.1p priority, 802.1Q VLAN tagging, 802.3x flow control, 802.3ad load-balancing and failover,
- Link aggregation, IEEE 802.3ad 802.3
- Multiple MAC addresses / promiscuous mode (for PowerVM/VIOS) per interface
- Message Signalling Interrupt (MSI-X, MSI) support of legacy pin interrupts
- Ether II and IEEE 802.3 encapsulated frames
- Jumbo frames up to 9.6 Kbytes
- TCP checksum offload for IPv4 and IPv6
- TCP segmentation Offload (TSO)
- RSS (Receive Side Scaling) support for IPv4, IPv6 and UDP.
- UDP checksum offload for IPv4 and IPv6
- Linux provides software iSCSI support through the adapter.
- Attributes provided: Two 10G-BaseT ports
- Attributes required: PCIe Gen2 or Gen3 slot - full high
- For 8205-E6D: (#EN0W)
- Minimum required: 0
- Maximum allowed: 5 (Initial order maximum: 5)
- OS level required:
- AIX Version 6.1 with the 6100-09 Technology Level and Service Pack 3 and APAR IV56366 or later
- AIX Version 7.1 with the 7100-03 Technology Level and Service Pack 3 and APAR IV56367 or later
- AIX Version 7.1 with the 7100-01 Technology Level and Service Pack 10 or later
- AIX Version 7.1 with the 7100-02 Technology Level and Service Pack 5 or later
- AIX Version 6.1 with the 6100-07 Technology Level and service Pack 10 or later
- AIX Version 6.1 with the 6100-08 Technology Level and service Pack 5 or later
- IBM i supported through VIOS
- SUSE Linux Enterprise 11 Service Pack 3, or later with current maintenance updates available from SUSE
- Red Hat Enterprise Linux for POWER V6.5 or later with current maintenance updates available from Red Hat
- Red Hat Enterprise Linux for POWER V7 or later with current maintenance updates available from Red Hat
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Assignment to the VIOS requires
- VIOS 2.2.3.3 with ifix IV56366 or later
- VIOS 2.2.2.5 or later
- VIOS 2.2.1.9 or later
(#EN0X) - PCIe2 LP 2-port 10/1GbE BaseT RJ45 Adapter
(No Longer Available as of March 31, 2018)
PCIe Gen2 short x8 adapter which provides two 10G-BaseT ports. The ports are RJ45. The ports default to auto negotiate the highest speed either 10Gb (10GBaseT), 1Gb (1000BaseT) or 100Mb (100BaseT) full duplex. Each RJ45 port's configuration is independent of the other. The adapter supports Ethernet NIC (Network Interface Card) traffic.
The RJ45 ports use 4-pair CAT-6A cabling for distances of up to 100 meters or CAT-6 cabling for distances up to 37 meters. CAT5 cabling is not tested and is not supported.
#EN0W and #EN0X are electronically identical with the same CCIN of 2CC4. #EN0W has a full high tail stock and #EN0X has a low profile tail stock.
Details for the ports include:
- AIX NIM and Linux Network Install are supported.
- IEEE 802.3an (10GBASE-T), IEEE 802.3ab (1000BASE-T GbE), IEEEu (100BASE-T), 802.1p priority, 802.1Q VLAN tagging, 802.3x flow control, 802.3ad load-balancing and failover,
- Link aggregation, IEEE 802.3ad 802.3
- Multiple MAC addresses / promiscuous mode (for PowerVM/VIOS) per interface
- Message Signalling Interrupt (MSI-X, MSI) support of legacy pin interrupts
- Ether II and IEEE 802.3 encapsulated frames
- Jumbo frames up to 9.6 Kbytes
- TCP checksum offload for IPv4 and IPv6
- TCP segmentation Offload (TSO)
- RSS (Receive Side Scaling) support for IPv4, IPv6 and UDP.
- UDP checksum offload for IPv4 and IPv6
- Linux provides software iSCSI support through the adapter.
- Attributes provided: Two 10G-BaseT ports
- Attributes required: PCIe Gen2 or Gen3 slot - low profile
- For 8205-E6D: (#EN0X)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- AIX Version 6.1 with the 6100-09 Technology Level and Service Pack 3 and APAR IV56366 or later
- AIX Version 7.1 with the 7100-03 Technology Level and Service Pack 3 and APAR IV56367 or later
- AIX Version 7.1 with the 7100-01 Technology Level and Service Pack 10 or later
- AIX Version 7.1 with the 7100-02 Technology Level and Service Pack 5 or later
- AIX Version 6.1 with the 6100-07 Technology Level and service Pack 10 or later
- AIX Version 6.1 with the 6100-08 Technology Level and service Pack 5 or later
- IBM i supported through VIOS
- SUSE Linux Enterprise 11 Service Pack 3, or later with current maintenance updates available from SUSE
- Red Hat Enterprise Linux for POWER V6.5 or later with current maintenance updates available from Red Hat
- Red Hat Enterprise Linux for POWER V7 or later with current maintenance updates available from Red Hat
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Assignment to the VIOS requires
- VIOS 2.2.3.3 with ifix IV56366 or later
- VIOS 2.2.2.5 or later
- VIOS 2.2.1.9 or later
(#EN0Y) - PCIe2 LP 8Gb 4-port Fibre Channel Adapter
(No Longer Available as of March 31, 2018)
PCIe Gen2 8 Gigabit quad port Fibre Channel Adapter is a low profile, high-performance 8x short form Host Bus Adapter (HBA). Each port provides single initiator capability over a fiber link or with NPIV, multiple initiator capability is provided. The ports have LC type connectors and utilize shortwave laser optics. The adapter operates at link speeds of 2, 4, and 8 Gbps and will automatically negotiate to the highest speed possible. LEDs on each port provide information on the status and link speed of the port. CCIN is EN0Y.
The adapter connects to a Fibre Channel switch. Direct device attachment has not been tested and is not supported.
N_Port ID Virtualization (NPIV) capability is supported through VIOS.
Cables are the responsibility of the customer. Use multimode fibre optic cables with short-wave lasers that adhere to the following specifications:
OM3 - multimode 50/125 micron fibre, 2000 MHz*km bandwidth
OM2 - multimode 50/125 micron fibre, 500 MHz*km bandwidth
OM1 - multimode 62.5/125 micron fibre, 200 MHz*km bandwidth
Because core sizes are different, OM1 cables can only be connected to other OM1 cables. For best results, OM2 cables should not be connected to OM3 cables. However, if an OM2 cable is connected to an OM3 cable, the characteristics of the OM2 cable apply to the entire length of the cables.
The following table shows the supported distances for the three different cable types at the three different link speeds.
Cable 2.125 Gbps 4.25 Gbps 8.5 Gbps
------ ------------ ----------- -----------
OM3 .5m - 500m .5m - 380m .5m - 150m
OM2 .5m - 300m .5m - 150m .5m - 50m
OM1 .5m - 150m .5m - 70m .5m - 21m
A Gen2 or later PCIe slot is required to provide the bandwidth for all four ports to operate at full speed. Use in Gen1 slots has not been tested and is not supported.
The EN12 and EN0Y adapters are electronically and functionally identical with the same CCIN of EN0Y. #EN12 indicates a full high tailstock bracket. #EN0Y indicates a low profile tailstock bracket.
Consult with your IBM representative or Business Partner for additional information relative to any third party attachment.
See also optional wrap plug feature #ECW0 which is:
- a) Required to run some diagnostic procedures and
- b) in some cases may speed system boot when placed in empty ports as well as avoid useless messages pointing to a planned empty port.
- Attributes provided: 4-port 8Gb Fibre Channel Adapter
- Attributes required: 1 Empty PCIe Gen2 slot
- For 8205-E6D: (#EN0Y)
- Minimum required: 0
- Maximum allowed: 4 (Initial order maximum: 4)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported -- VIOS required
- IBM i 7.1 supported -- VIOS required
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EPCP) - 6-core 4.2 GHz POWER7+ Processor Module
(No Longer Available as of March 31, 2018)
6-core 4.2 GHz processor module. This feature is only available to SDIs as an MES order.
- Attributes provided: 6-core 4.2 GHz processor module
- Attributes required: None
- For 8205-E6D: (#EPCP)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 2)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
(#EPCQ) - 8-core 3.6 GHz POWER7+ Processor Module
(No Longer Available as of March 31, 2018)
8-core 3.6 GHz processor module. This feature is only available to SDIs as an MES order.
- Attributes provided: 8-core 3.6 GHz processor module
- Attributes required: None
- For 8205-E6D: (#EPCQ)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 2)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
(#EPCR) - 8-core 4.2 GHz POWER7+ Processor Module
(No Longer Available as of July 26, 2016)
8-core 4.2 GHz processor module. This feature is only available to SDIs as an MES order.
- Attributes provided: 8-core 4.2 GHz processor module
- Attributes required: None
- For 8205-E6D: (#EPCR)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 2)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: No
- Return parts MES: No
(#EPDP) - One Processor Activation for Processor Feature #EPCP
(No Longer Available as of December 31, 2018)
This feature number will activate one processor on a #EPCP processor module.
- Attributes provided: One processor activation for processor #EPCP
- Attributes required: Feature number EPCP
- For 8205-E6D: (#EPDP)
- Minimum required: 0
- Maximum allowed: 12 (Initial order maximum: 12)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EPDQ) - One Processor Activation for Processor Feature #EPCQ
(No Longer Available as of December 31, 2018)
This feature number will activate one processor on a #EPCQ processor module.
- Attributes provided: One processor activation for processor #EPCQ
- Attributes required: Feature number EPCQ
- For 8205-E6D: (#EPDQ)
- Minimum required: 0
- Maximum allowed: 16 (Initial order maximum: 16)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EPDR) - One Processor Activation for Processor Feature #EPCR
(No Longer Available as of December 31, 2018)
This feature number will activate one processor on a #EPCR processor module.
- Attributes provided: One processor activation for processor #EPCR
- Attributes required: Feature number EPCR
- For 8205-E6D: (#EPDR)
- Minimum required: 0
- Maximum allowed: 16 (Initial order maximum: 16)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EPEP) - Zero-priced Processor Activation for #EPCP
(No longer available as of January 18, 2019)
This feature number will provide the customer with one processor activation at no additional charge. Available only with qualifying IBM Edition
- Attributes provided: One processor activation for #EPCP
- Attributes required: Qualifying IBM Edition
- For 8205-E6D: (#EPEP)
- Minimum required: 0
- Maximum allowed: 6 (Initial order maximum: 6)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EPEQ) - Zero-priced Processor Activation for #EPCQ
(No longer available as of January 18, 2019)
This feature number will provide the customer with one processor activation at no additional charge. Available only with qualifying IBM Edition
- Attributes provided: One processor activation for #EPCQ
- Attributes required: Qualifying IBM Edition
- For 8205-E6D: (#EPEQ)
- Minimum required: 0
- Maximum allowed: 8 (Initial order maximum: 8)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EPER) - Zero-priced Processor Activation for #EPCR
(No longer available as of January 18, 2019)
This feature number will provide the customer with one processor activation at no additional charge. Available only with qualifying IBM Edition
- Attributes provided: One processor activation for #EPCR
- Attributes required: Qualifying IBM Edition
- For 8205-E6D: (#EPER)
- Minimum required: 0
- Maximum allowed: 8 (Initial order maximum: 8)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EQ02) Quanity 150 of #3452 SAS YO Cable 6m - HD 6Gb Adapter to Enclosure
This feature provides 150 cables of feature 3452 which is a 6 meter SAS cable that connects a SAS adapter to a SAS I/O enclosure. This YO cable has three connectors, one Mini-SAS HD (High Density)connector and two Mini SAS connectors. The Mini-SAS HD connector attaches to a SAS adapter such as the #5913 1.8GB RAID SAS Adapter. Both Mini SAS connectors attach to the same I/O drawer (enclosure) such as a #5887 EXP24S SAS I/O drawer. This cable can support up to 6Gb throughput.
Multiple cable length feature codes are available. Choose the cable length that best matches the distance between the adapter and the SAS I/O drawer.
- Attributes provided: connection between SAS adapter with Mini-SAS HD connectors and a SAS I/O drawer with Mini SAS connectors.
- Attributes required: Available connectors on SAS controller and SAS I/O drawer.
- For 8205-E6D: (#EQ02)
- Minimum required: 0
- Maximum allowed: 3 (Initial order maximum: 3)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EQ03) Quantity 150 of #3453 SAS YO Cable 10m - HD 6Gb Adapter to Enclosure
This feature provides 150 10 meter SAS cables that connects a SAS adapter to a SAS I/O enclosure. This YO cable has three connectors, one Mini-SAS HD (High Density)connector and two Mini SAS connectors. The Mini-SAS HD connector attaches to a SAS adapter such as the #5913 1.8GB RAID SAS Adapter. Both Mini SAS connectors attach to the same I/O drawer (enclosure) such as a #5887 EXP24S SAS I/O drawer. This cable can support up to 6Gb throughput.
Multiple cable length feature codes are available. Choose the cable length that best matches the distance between the adapter and the SAS I/O drawer.
- Attributes provided: connection between SAS adapter with Mini-SAS HD connectors and a SAS I/O drawer with Mini SAS connectors
- Attributes required: available connectors on SAS controller and SAS I/O drawer
- For 8205-E6D: (#EQ03)
- Minimum required: 0
- Maximum allowed: 3 (Initial order maximum: 3)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EQ0C) - Quantity of 150 #ES0C
(No Longer Available as of July 11, 2014)
This feature ships a quantity of 150 #ES0C disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records
- Attributes provided: Quantity of 150 #ES0C
- Attributes required: See Feature ES0C
- For 8205-E6D: (#EQ0C)
- Minimum required: 0
- Maximum allowed: 3 (Initial order maximum: 3)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EQ0D) - Quantity of 150 #ES0D
(No Longer Available as of July 11, 2014)
This feature ships a quantity of 150 #ES0D disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records
- Attributes provided: Quantity of 150 #ES0D
- Attributes required: See feature ES0D
- For 8205-E6D: (#EQ0D)
- Minimum required: 0
- Maximum allowed: 3 (Initial order maximum: 3)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EQ0G) - Quantity 150 of #ES0G (775GB SSD SFF-2)
(No Longer Available as of August 31, 2017)
This feature ships a quantity of 150 #ES0G disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records
- Attributes provided: Quantity of 150 #ES0G
- Attributes required: See Feature ES0G
- For 8205-E6D: (#EQ0G)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 2)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i - not supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EQ0H) - Quantity 150 of #ES0H (775GB SSD SFF-2)
(No Longer Available as of August 31, 2017)
This feature ships a quantity of 150 #ES0H disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records
- Attributes provided: Quantity of 150 #ES0H
- Attributes required: See feature ES0H
- For 8205-E6D: (#EQ0H)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 2)
- OS level required:
- IBM i 6.1 with machine code 6.1.1, or later
- IBM i 7.1, or later
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EQ19) - Quantity 150 of #ES19 (387GB SSD SFF-2)
(No Longer Available as of August 31, 2017)
This feature ships a quantity of 150 #ES19 disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records
- Attributes provided: Quantity of 150 #ES19
- Attributes required: See Feature ES19
- For 8205-E6D: (#EQ19)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 2)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i - not supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EQ1A) - Quantity 150 of #ES1A (387GB SSD SFF-2)
(No Longer Available as of August 31, 2017)
This feature ships a quantity of 150 #ES1A disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records
- Attributes provided: Quantity of 150 #ES1A
- Attributes required: See feature ES1A
- For 8205-E6D: (#EQ1A)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 2)
- OS level required:
- IBM i 7.1, or later
- IBM i 6.1 with machine code 6.1.1, or later
- AIX - not supported
- Linux - not supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EQ38) - Quantity 150 of #1738 (856GB SFF-2 disk)
(No Longer Available as of January 20, 2017)
This feature ships a quantity of 150 #1738 disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records.
- Attributes provided: see feature #1738
- Attributes required: see feature #1738
- For 8205-E6D: (#EQ38)
- Minimum required: 0
- Maximum allowed: 3 (Initial order maximum: 3)
- OS level required:
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EQ52) - Quantity 150 of #1752 (900GB SFF-2 disk)
(No Longer Available as of January 20, 2017)
This feature ships a quantity of 150 #1752 disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records.
- Attributes provided: see feature #1752
- Attributes required: see feature #1752
- For 8205-E6D: (#EQ52)
- Minimum required: 0
- Maximum allowed: 3 (Initial order maximum: 3)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EQ78) - Quantity 150 of #ES78 387GB SFF-2 SSD 5xx
(No Longer Available as of March 31, 2018)
This feature ships a quantity of 150 #ES78 solid state drives (SSDs). The configurator may either generate this feature or allow users to select this feature as they would any other single SSD feature. This feature remains on the inventory records.
- Attributes provided: Ships 150 SSDs
- Attributes required: See feat #ES78
- For 8205-E6D: (#EQ78)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 0)
- OS level required: Refer to feature #ES78
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#EQ79) - Quantity 150 of #ES79 387GB SFF-2 SSD 5xx
(No Longer Available as of March 31, 2018)
This feature ships a quantity of 150 #ES79 solid state drives (SSDs). The configurator may either generate this feature or allow users to select this feature as they would any other single SSD feature. This feature remains on the inventory records.
- Attributes provided: Ships 150 SSDs
- Attributes required: See feat #ES79
- For 8205-E6D: (#EQ79)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 0)
- OS level required: Refer to feature #ES79
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#EQ7E) - Quantity 150 of #ES7E 775GB SFF-2 SSD 5xx
(No Longer Available as of March 31, 2018)
This feature ships a quantity of 150 #ES7E solid state drives (SSDs). The configurator may either generate this feature or allow users to select this feature as they would any other single SSD feature. This feature remains on the inventory records.
- Attributes provided: Ships 150 SSDs
- Attributes required: See feat #ES7E
- For 8205-E6D: (#EQ7E)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 0)
- OS level required: Refer to feature #ES7E
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#EQ7F) - Quantity 150 of #ES7F 775GB SFF-2 SSD 5xx
(No Longer Available as of March 31, 2018)
This feature ships a quantity of 150 #ES7F solid state drives (SSDs). The configurator may either generate this feature or allow users to select this feature as they would any other single SSD feature. This feature remains on the inventory records.
- Attributes provided: Ships 150 SSDs
- Attributes required: See feat #ES7F
- For 8205-E6D: (#EQ7F)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 2)
- OS level required: Refer to feature #ES7F
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EQD2) - Quantity 150 of #ESD2 (1.1TB 10k SFF-2)
(No Longer Available as of March 31, 2018)
This feature ships a quantity of 150 #ESD2 disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records.
- Attributes provided: See feature #ESD2
- Attributes required: 150 SFF-2 SAS bays in EXP24S drawers
- For 8205-E6D: (#EQD2)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 2)
- OS level required:
- IBM i - 7.1, or later
- AIX - not supported
- Linux - not supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EQD3) - Quantity 150 of #ESD3 (1.2TB 10k SFF-2)
(No Longer Available as of March 31, 2018)
This feature ships a quantity of 150 #ESD3 1.2TB SAS 10K SFF-2 disk units. The configurator may either generate this feature or allow users to select this feature as they would any other single disk unit feature. This feature remains on the inventory records.
- Attributes provided: See feature#ESD3
- Attributes required: 150 SFF-2 SAS bays in EXP24S drawers
- For 8205-E6D: (#EQD3)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 2)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Red Hat Enterprise Linux 5.8 for Power, or later
- Red Hat Enterprise Linux 6.2 for Power, or later
- SUSE Linux Enterprise 10, Service Pack 4, or later
- SUSE Linux Enterprise 11, Service Pack 2, or later
- IBM i - not supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EQDN) - Quantity 150 of #ESDN (571GB 15K RPM SAS SFF-2 for IBM i)
(No Longer Available as of March 31, 2018)
This feature ships a quantity 150 of #ESDN drive. The configurator may either generate this feature or allow users to select this feature as they would any other single disk drive feature. This feature remains on the inventory records.
- Attributes provided: Quantity 150 of #ESDN
- Attributes required: See #ESDN
- For 8205-E6D: (#EQDN)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 2)
- OS level required:
- IBM i - supported refer to #ESDN
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EQDP) Quantity 150 of #ESDP (600GB 15K RPM SAS SFF-2 for AIX/LINUX)
(No Longer Available as of March 31, 2018)
This feature ships a quantity 150 of #ESDP drive. The configurator may either generate this feature or allow users to select this feature as they would any other single disk drive feature. This feature remains on the inventory records.
- Attributes provided: Quantity 150 of #ESDP
- Attributes required: See #ESDP
- For 8205-E6D: (#EQDP)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 2)
- OS level required:
- Red Hat Enterprise Linux
- SUSE Linux Enterprise Server
- AIX 6.1 and 7.1 or later supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ER05) - 42U Slim Rack
(No Longer Available as of March 31, 2018)
Provides a 19-inch, 2.0 meter high rack with 42 EIA units of total space for installing rack mounted CECs and/or expansion units. The 600mm wide rack fits within a data center's 24" floor tiles and provides better thermal and cable management capabilities. The following features are required on the #ER05:
- #EC01 front door
- #EC02 rear door or #EC05 Rear Door Heat Exchanger (RDHX) indicator
PDUs on the rack are optional. Each #7196 and #7189 PDU consumes one of six vertical mounting bays. Each PDU beyond four will consume 1U of rack space.
- Attributes provided: 19", 42U of vertical space
- Attributes required: #EC01 front door, #EC02 rear door or #EC05 RDHX indicator
- For 8202-E4D: (#ER05)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#ERF1) RFID Tags for Servers, Compute Nodes, Chassis, Racks, and HMCs
(No Longer Available as of November 30, 2015)
The specify feature attaches one Radio Frequency Identification Device (RFID) tag to a Server CEC, rack, HMC, compute node, or chassis enclosure. This can be used with MTM (machine type model) rack such as a 7953-94X or 7014-T42, not a feature code rack such as a #0553. It applies to newly shipped MTM servers, racks, HMCs, compute nodes, and chassis enclosures, not MES orders with one exception. POWER5 CECs being upgraded to a POWER6 CEC or POWER6 CECs being upgraded to a POWER 7 CEC can order this feature. The RFID tag meets the Financial Services Technology Consortium (FSTC) specifications for IT Data Center Asset Tracking.
- Attributes provided: RFIDs
- Attributes required: Server CEC, Compute Node, Chassis, MTM Rack, or HMC
- For 8205-E6D: (#ERF1)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#ES02) - 387GB 1.8" SAS SSD for AIX/Linux with eMLC
(No Longer Available as of February 27, 2015)
This Solid State Drive (SSD) is shipped from IBM with 528-byte sector RAID formatting to provide 387 GB capacity for AIX/Linux. It is placed in a 1.8" SAS bay of the EXP30 Ultra SSD I/O Drawer.
Feature #ES02 CCIN is 58BB. Enterprise Multi-Level Cell (eMLC) technology is used to provide extremely reliable, cost effective, dense SSD storage.
Limitation: JBOD mode for AIX/Linux is not supported.
- Attributes provided: 387GB Solid State Drive
- Attributes required: None
- For 8205-E6D: (#ES02)
- Minimum required: 0
- Maximum allowed: 120 (Initial order maximum: 120)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 30 per #EDR1
(#ES04) - 387GB 1.8" SAS SSD for IBM i with eMLC
(No Longer Available as of February 27, 2015)
(#ES04) - 387GB 1.8" SAS SSD for IBM i with eMLC This Solid State Drive (SSD) is shipped from IBM with 528-byte sector RAID formatting to provide 387 GB capacity for AIX/IBM i/ Linux. It is placed in a 1.8" SAS bay of the EXP30 Ultra SSD I/O Drawer.
Feature #ES02 and #ES04 are physically identical and have the same CCIN = 58BB, but two features are used to allow IBM configurator tools to understand usage by either AIX/Linux/VIOS or IBM i. #ES02 indicates AIX/Linux/VIOS usage. #ES04 indicates IBM i usage. Enterprise Multi-Level Cell (eMLC) technology is used to provide extremely reliable, cost effective, dense SSD storage.
Limitation: Drive was not tested with 512 byte sectors and thus JBOD mode for AIX/Linux is not supported
- Attributes provided: 387GB SATA Solid State Drive
- Attributes required: None
- For 8205-E6D: (#ES04)
- Minimum required: 0
- Maximum allowed: 60 (Initial order maximum: 60)
- OS level required:
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 30 per #EDR1
(#ES09) - IBM Flash Adapter 90 (PCIe2 0.9TB)
(No Longer Available as of March 31, 2018)
This Flash feature provides:
- Up to 325K read IOPs and less than 100 micro second latency
- 0.9TB of usable enterprise multi level cell (eMLC) flash memory
- Four independent flash controllers with low host CPU overhead and patented reliability features
- Capacitive emergency power loss protection
- Half-length, full-height PCIe card form factor
- PCIe 2.0 x8 interface for optimum performance
As of 4Q2013, #ES09 support is not included in base AIX installation media. Acquire AIX feature support at IBM Fix Central: http://www-933.ibm.com/support/fixcentral/ by selecting the Product Group System Storage.
- Attributes provided: 0.9TB eMLC Flash Memory
- Attributes required: Available full high PCIe2 slot in CEC for maximum bandwidth or a PCIe slot in a #5802/5877 I/O drawer
- For 8205-E6D: (#ES09)
- Minimum required: 0
- Maximum allowed: 20 (Initial order maximum: 20)
- OS level required:
- AIX V7.1 with the 7100-03 Technology Level or later (planned availability date 11/29/2013)
- AIX V6.1 with the 6100-09 Technology Level or later (planned availability date 11/29/2013)
- IBM i - not supported
- Red Hat Linux 6.5 for POWER, or later
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
Limitation
- Max 4 per CEC
- Max 4 per LPAR
- Max 4 per I/O Drawer (#5802 or #5877)
- Boot is not supported
- VIOS - not supported
- Adapter support is not included on base AIX installation media. Installation of separate software package is required. AIX support for this feature can be acquired at IBM Fix Central:
- http://www-933.ibm.com/support/fixcentral/ by selecting the Product Group System Storage.
(#ES0A) - 387GB SFF-1 SSD for AIX/Linux with eMLC
(No Longer Available as of July 11, 2014)
This SFF (2.5") SAS Solid State Drive (SSD) is shipped from IBM with 387 GB capacity formatted with 528 byte sectors. The drive is supported in SFF SAS bays in the #5802/#5803 I/O drawers or in system unit SFF SAS bays. CCIN is 58B8.
ES0A and ES0B are physically identical drives which have different feature codes to help the IBM configuration tools understand how the SSD is used. ES0A indicates usage by AIX, Linux or VIOS. ES0B indicates usage by IBM i.
Limitation: can not be used in #5887 EXP24S Gen2 I/O drawer due to physical difference in Gen1 and Gen2 carriers. Also drive was not tested with 512 byte sectors and thus JBOD mode for AIX/Linux is not supported
- Attributes provided: 387GB SFF-1 SSD formatted with 528 byte formatting
- Attributes required: One SFF-1 SAS bay
- For 8205-E6D: (#ES0A)
- Minimum required: 0
- Maximum allowed: 80 (Initial order maximum: 80)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ES0B) - 387GB SFF-1 SSD for IBM i with eMLC
(No Longer Available as of July 11, 2014)
This SFF (2.5") SAS Solid State Drive (SSD) is shipped from IBM with 387 GB capacity formatted with 528 byte sectors. The drive is supported in SFF SAS bays in the #5802/#5803 I/O drawers or in system unit SFF SAS bays. CCIN is 58B8.
ES0A and ES0B are physically identical drives which have different feature codes to help the IBM configuration tools understand how the SSD is used. ES0A indicates usage by AIX, Linux or VIOS. ES0B indicates usage by IBM i.
Limitation: can not be used in #5887 EXP24S Gen2 I/O drawer due to physical difference in Gen1 and Gen2 carriers. Also drive was not tested with 512 byte sectors and thus JBOD mode for AIX/Linux is not supported
- Attributes provided: 387GB SFF-1 SSD with 528 byte formatting
- Attributes required: One SFF-1 SAS bay
- For 8205-E6D: (#ES0B)
- Minimum required: 0
- Maximum allowed: 80 (Initial order maximum: 80)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ES0C) - 387GB SFF-2 SSD for AIX/Linux with eMLC
(No Longer Available as of July 11, 2014)
This SFF (2.5") SAS Solid State Drive (SSD) is shipped from IBM with 387 GB capacity formatted with 528 byte sectors. The drive is supported in SFF-2 SAS bays in the #5887 I/O drawer. CCIN is 58B9.
ES0C and ES0D are physically identical drives which have different feature codes to help the IBM configuration tools understand how the SSD is used. ES0C indicates usage by AIX, Linux or VIOS. ES0D indicates usage by IBM i.
Limitation: can not be used in #5802/#5803 I/O drawers or in system unit SFF SAS bays due to physical difference in Gen1 and Gen2 carriers. Also drive was not tested with 512 byte sectors and thus JBOD mode for AIX/Linux is not supported
- Attributes provided: 387GB SFF-2 SSD formatted with 528 byte formatting
- Attributes required: One SFF-2 SAS bay
- For 8205-E6D: (#ES0C)
- Minimum required: 0
- Maximum allowed: 336 (Initial order maximum: 250)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ES0D) - 387GB SFF-2 SSD for IBM i with eMLC
(No Longer Available as of July 11, 2014)
This SFF (2.5") SAS Solid State Drive (SSD) is shipped from IBM with 387 GB capacity formatted with 528 byte sectors. The drive is supported in SFF-2 SAS bays in the #5887 I/O drawer. CCIN is 58B9.
ES0C and ES0D are physically identical drives which have different feature codes to help the IBM configuration tools understand how the SSD is used. ES0C indicates usage by AIX, Linux or VIOS. ES0D indicates usage by IBM i.
Limitation: can not be used in #5802/#5803 I/O drawers or in system unit SFF SAS bays due to physical difference in Gen1 and Gen2 carriers. Also drive was not tested with 512 byte sectors and thus JBOD mode for AIX/Linux is not supported
- Attributes provided: 387GB SFF-2 SSD formatted with 528 byte formatting
- Attributes required: One SFF-2 SAS bay
- For 8205-E6D: (#ES0D)
- Minimum required: 0
- Maximum allowed: 336 (Initial order maximum: 250)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ES0E) - 775GB SFF-1 SSD for AIX/Linux
(No Longer Available as of August 31, 2017)
This SFF (2.5") SAS Solid State Drive (SSD) is shipped from IBM with 775 GB capacity formatted with 528 byte sectors. The drive is supported in SFF SAS bays in the #5802/#5803 I/O drawers or in system unit SFF-1 SAS bays. CCIN is 59C0.
ES0E and ES0F are physically identical drives which have different feature codes to help the IBM configuration tools understand how the SSD is used. ES0A indicates usage by AIX, Linux or VIOS. ES0B indicates usage by IBM i.
Limitation: can not be used in #5887 EXP24S Gen2 I/O drawer due to physical difference in Gen1 and Gen2 carriers. Also drive was not tested with 512 byte sectors and thus JBOD mode for AIX/Linux is not supported
- Attributes provided: 775GB SFF-1 SSD formatted with 528 byte sectors
- Attributes required: One SFF SAS bay
- For 8205-E6D: (#ES0E)
- Minimum required: 0
- Maximum allowed: 80 (Initial order maximum: 80)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i - not supported
- Linux supported
- IBM i - not supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ES0F) - 775GB SFF-1 SSD for IBM i
(No Longer Available as of August 31, 2017)
This SFF (2.5") SAS Solid State Drive (SSD) is shipped from IBM with 775 GB capacity formatted with 528 byte sectors. The drive is supported in SFF SAS bays in the #5802/#5803 I/O drawers or in system unit SFF-1 SAS bays. CCIN is 59C0.
ES0E and ES0F are physically identical drives which have different feature codes to help the IBM configuration tools understand how the SSD is used. ES0E indicates usage by AIX, Linux or VIOS. ES0F indicates usage by IBM i.
Limitation: cannnot be used in #5887 EXP24S Gen2 I/O drawer due to physical difference in Gen1 and Gen2 carriers. Also drive was not tested with 512 byte sectors and thus JBOD mode for AIX/Linux is not supported
- Attributes provided: 775GB SFF-1 SSD formatted with 528 byte sectors
- Attributes required: One SFF SAS bay
- For 8205-E6D: (#ES0F)
- Minimum required: 0
- Maximum allowed: 80 (Initial order maximum: 80)
- OS level required:
- AIX - not supported
- Linux - not supported
- IBM i 6.1 with machine code 6.1.1, or later
- IBM i 7.1, or later
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ES0G) - 775GB SFF-2 SSD for AIX/Linux
(No Longer Available as of August 31, 2017)
This SFF (2.5") SAS Solid State Drive (SSD) is shipped from IBM with 387 GB capacity formatted with 528 byte sectors. The drive is supported in SFF-2 SAS bays in the #5887 I/O drawer. CCIN is TBD.
ES0G and ES0H are physically identical drives which have different feature codes to help the IBM configuration tools understand how the SSD is used. ES0G indicates usage by AIX, Linux or VIOS. ES0H indicates usage by IBM i.
Limitation: cannnot be used in #5802/#5803 I/O drawers or in system unit SFF-1 SAS bays due to physical difference in Gen1 and Gen2 carriers. Also drive was not tested with 512 byte sectors and thus JBOD mode for AIX/Linux is not supported
- Attributes provided: 775GB SFF-2 SSD formatted with 528 byte sectors
- Attributes required: One SFF-2 SAS bay in EXP24S drawer
- For 8205-E6D: (#ES0G)
- Minimum required: 0
- Maximum allowed: 336 (Initial order maximum: 250)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ES0H) - 775GB SFF-2 SSD for IBM i
(No Longer Available as of August 31, 2017)
This SFF (2.5") SAS Solid State Drive (SSD) is shipped from IBM with 387 GB capacity formatted with 528 byte sectors. The drive is supported in SFF-2 SAS bays in the #5887 I/O drawer. CCIN is TBD.
ES0G and ES0H are physically identical drives which have different feature codes to help the IBM configuration tools understand how the SSD is used. ES0G indicates usage by AIX, Linux or VIOS. ES0H indicates usage by IBM i.
Limitation: cannnot be used in #5802/#5803 I/O drawers or in system unit SFF-1 SAS bays due to physical difference in Gen1 and Gen2 carriers. Also drive was not tested with 512 byte sectors and thus JBOD mode for AIX/Linux is not supported
- Attributes provided: 775GB SFF-2 SSD formatted with 528 byte sectors
- Attributes required: One SFF-2 SAS bay in EXP24S drawer
- For 8205-E6D: (#ES0H)
- Minimum required: 0
- Maximum allowed: 336 (Initial order maximum: 250)
- OS level required:
- IBM i 7.1, or later
- IBM i 6.1 with machine code 6.1.1, or later
- AIX - not supported
- Linux - not supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ES0J) - 387GB 1.8" SSD for AIX/Linux
(No Longer Available as of March 31, 2018)
This Solid State Drive (SSD) is shipped from IBM with 528-byte sector RAID formatting to provide 387 GB capacity. It is placed in a 1.8" SAS bay. Enterprise Multi-Level Cell (eMLC) technology provides extremely reliable, cost effective, dense SSD storage. CCIN is 59BE.
Note that #ES0J and #ES0K are identical, but use different feature codes to help IBM configuration tools understand their usage.
Limitation: JBOD mode for AIX/Linux is not supported.
- Attributes provided: 1.8-inch eMLC SSD with 387GB capacity
- Attributes required: Availalbe 1.8-inch SSD bay. In an EXP30 Ultra SSD Drawer (#EDR1 or #5888) one #EB2W carrier/tray is required.
- For 8205-E6D: (#ES0J)
- Minimum required: 0
- Maximum allowed: 120 (Initial order maximum: 120)
- OS level required:
- AIX - supported
- Linux - supported
- IBM i - not supported
- Refer to the Software Requirements section to find the uspported O/S Levels.
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ES0K) - 387GB 1.8" SSD for IBM i
(No Longer Available as of March 31, 2018)
This Solid State Drive (SSD) is shipped from IBM with 528-byte sector RAID formatting to provide 387 GB capacity. It is placed in a 1.8" SAS bay. Enterprise Multi-Level Cell (eMLC) technology provides extremely reliable, cost effective, dense SSD storage. CCIN is 59BE.
Note that #ES0J and #ES0K are identical, but use different feature codes to help IBM configuration tools understand their usage.
- Attributes provided: 1.8-inch eMLC SSD with 387GB capacity
- Attributes required: Availalbe 1.8-inch SSD bay. In an EXP30 Ultra SSD Drawer (#EDR1 or #5888) one #EB2W carrier/tray is required.
- For 8205-E6D: (#ES0K)
- Minimum required: 0
- Maximum allowed: 60 (Initial order maximum: 60)
- OS level required:
- AIX - not supported
- Linux - not supported
- IBM i 7.1 and 7.2 or later
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ESRJ) - Six ES0J 387GB 1.8" SSD for AIX/Linux
(No Longer Available as of November 30, 2015)
Provides six (6) ES0J 387GB 1.8-inch SSD.
Note that #ESRJ and #ESRK are identical, but use different feature codes to help IBM configuration tools understand their usage.
- Attributes provided: Six 1.8-inch eMLC SSD with 387GB capacity
- Attributes required: Six availalbe 1.8-inch SSD bays. In an EXP30 Ultra SSD Drawer (#EDR1 or #5888) six #EB2W carrier/tray are required.
- For 8205-E6D: (#ESRJ)
- Minimum required: 0
- Maximum allowed: 20 (Initial order maximum: 20)
- OS level required: ES0J
- AIX - supported
- Linux - supported
- IBM i - not supported
- Refer to the Software Requirements section to find the uspported O/S Levels.
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#ESRK) - Six ES0K 387GB 1.8" SSD for IBM i
(No Longer Available as of November 30, 2015)
Provides six (6) ES0K 387GB 1.8-inch SSD.
Note that #ESRJ and #ESRK are identical, but use different feature codes to help IBM configuration tools understand their usage.
- Attributes provided: Six 1.8-inch eMLC SSD with 387GB capacity
- Attributes required: Six availalbe 1.8-inch SSD bays. In an EXP30 Ultra SSD Drawer (#EDR1 or #5888) six #EB2W carrier/tray are required.
- For 8205-E6D: (#ESRK)
- Minimum required: 0
- Maximum allowed: 10 (Initial order maximum: 10)
- OS level required:
- AIX - not supported
- Linux - not supported
- IBM i 7.1 and 7.2 or later
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#ES10) - 387GB SFF-1 SSD for AIX/Linux
(No Longer Available as of August 31, 2017)
This SFF (2.5") SAS Solid State Drive (SSD) is shipped from IBM with 387 GB capacity formatted with 528 byte sectors. The drive is supported in SFF SAS bays in the #5802/#5803/#EL36 I/O drawers or in system unit SFF-1 SAS bays. CCIN is 58B8.
#ES10 and #ES11 are physically identical drives which have different feature codes to help the IBM configuration tools understand how the SSD is used. #ES10 indicates usage by AIX, Linux or VIOS. #ES11 indicates usage by IBM i.
#ES10/ES11 and the earlier ES0A/ES0B are all 387GB SSD and can be mixed in the same array.
Limitation: cannnot be used in #5887/#EL1S EXP24S Gen2 I/O drawer due to physical difference in Gen1 and Gen2 carriers. Also drive was not tested with 512 byte sectors and thus JBOD mode for AIX/Linux is not supported
- Attributes provided: 387GB SFF-1 SSD formatted with 528 byte sectors
- Attributes required: One SFF-1 SAS bay
- For 8205-E6D: (#ES10)
- Minimum required: 0
- Maximum allowed: 80 (Initial order maximum: 80)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ES11) - 387GB SFF-1 SSD for IBM i
(No Longer Available as of August 31, 2017)
This SFF (2.5") SAS Solid State Drive (SSD) is shipped from IBM with 387 GB capacity formatted with 528 byte sectors. The drive is supported in SFF SAS bays in the #5802/#5803/#EL36 I/O drawers or in system unit SFF-1 SAS bays. CCIN is 58B8.
#ES10 and #ES11 are physically identical drives which have different feature codes to help the IBM configuration tools understand how the SSD is used. #ES10 indicates usage by AIX, Linux or VIOS. #ES11 indicates usage by IBM i.
#ES10/ES11 and the earlier ES0A/ES0B are all 387GB SSD and can be mixed in the same array.
Limitation: cannnot be used in #5887/#EL1S EXP24S Gen2 I/O drawer due to physical difference in Gen1 and Gen2 carriers. Also drive was not tested with 512 byte sectors and thus JBOD mode for AIX/Linux is not supported
- Attributes provided: 387GB SFF-1 SSD formatted with 528 byte sectors
- Attributes required: One SFF-1 SAS bay
- For 8205-E6D: (#ES11)
- Minimum required: 0
- Maximum allowed: 80 (Initial order maximum: 80)
- OS level required:
- IBM i 7.1, or later
- IBM i 6.1 with machine code 6.1.1, or later
- AIX - not supported
- Linux - not supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ES19) - 387GB SFF-2 SSD for AIX/Linux
(No Longer Available as of August 31, 2017)
This SFF (2.5") SAS Solid State Drive (SSD) is shipped from IBM with 387 GB capacity formatted with 528 byte sectors. The drive is supported in SFF-2 SAS bays in the #5887 EXP24S I/O drawer. CCIN is 58B9.
This SFF (2.5") SAS Solid State Drive (SSD) is shipped from IBM with 387 GB capacity formatted with 528 byte sectors. The drive is supported in SFF SAS bays in the #5802/#5803/#EL36 I/O drawers or in system unit SFF-1 SAS bays. CCIN is 58B8.
#ES19 and #ES1A are physically identical drives which have different feature codes to help the IBM configuration tools understand how the SSD is used. #ES19 indicates usage by AIX, Linux or VIOS. #ES1A indicates usage by IBM i.
#ES19/ES1A and the earlier ES0C/ES0D are all 387GB SSD and can be mixed in the same array.
Limitation: cannnot be used in #5802/5803/EL36 I/O drawers or in a system unit SFF-1 SAS bay due to physical difference in Gen1 and Gen2 carriers. Also drive was not tested with 512 byte sectors and thus JBOD mode for AIX/Linux is not supported
- Attributes provided: 387GB SFF-2 SSD formatted with 528 byte sectors
- Attributes required: One SFF-2 SAS bay in EXP24S drawer
- For 8205-E6D: (#ES19)
- Minimum required: 0
- Maximum allowed: 336 (Initial order maximum: 250)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- IBM i - not supported Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ES1A) - 387GB SFF-2 SSD for IBM i
(No Longer Available as of August 31, 2017)
This SFF (2.5") SAS Solid State Drive (SSD) is shipped from IBM with 387 GB capacity formatted with 528 byte sectors. The drive is supported in SFF-2 SAS bays in the #5887 EXP24S I/O drawer. CCIN is 58B9.
This SFF (2.5") SAS Solid State Drive (SSD) is shipped from IBM with 387 GB capacity formatted with 528 byte sectors. The drive is supported in SFF SAS bays in the #5802/#5803/#EL36 I/O drawers or in system unit SFF-1 SAS bays. CCIN is 58B8.
#ES19 and #ES1A are physically identical drives which have different feature codes to help the IBM configuration tools understand how the SSD is used. #ES19 indicates usage by AIX, Linux or VIOS. #ES1A indicates usage by IBM i.
#ES19/ES1A and the earlier ES0C/ES0D are all 387GB SSD and can be mixed in the same array.
Limitation: cannnot be used in #5802/5803/EL36 I/O drawers or in a system unit SFF-1 SAS bay due to physical difference in Gen1 and Gen2 carriers. Also drive was not tested with 512 byte sectors and thus JBOD mode for AIX/Linux is not supported
- Attributes provided: 387GB SFF-2 SSD formatted with 528 byte sectors
- Attributes required: One SFF-2 SAS bay in EXP24S drawer
- For 8205-E6D: (#ES1A)
- Minimum required: 0
- Maximum allowed: 336 (Initial order maximum: 250)
- OS level required:
- IBM i 7.1, or later
- IBM i 6.1 with machine code 6.1.1, or later
- AIX - not supported
- Linux - not supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ES78) - 387GB SFF-2 SSD 5xx eMLC4 for AIX/Linux
(No Longer Available as of March 31, 2018)
This SFF (2.5") SAS Solid State Drive (SSD) is shipped from IBM with 387 GB capacity formatted with 5xx (528) byte sectors. The drive is supported in SFF-2 SAS bays. CCIN is 5B16
- ES78 and ES79 are physically identical drives which have different feature codes to help the IBM configuration tools understand how the SSD is used. ES78 indicates usage by AIX, Linux or VIOS. ES79 indicates usage by IBM i.
- Limitation: Due to physical differences in the carrier/tray on which the drive is mounted, the SSD only fits in #5887/#EL1S EXP24S drawers (SFF-2). It does not fit in #5802/#5803 I/O drawers (SFF-1) or in POWER7 system units (SFF-1) or POWER8 system units (SFF-3) SAS bays. Also the drive was not tested with 512 byte sectors and thus JBOD mode for AIX/Linux is not supported. Note 4k and 5xx byte sector drives cannot be mixed in the same array. 4k drives can not be reformatted to 5xx drives (or vice versa).
- Attributes provided: one 387GB SFF-2 5xx SSD
- Attributes required: one SFF-2 SAS bay
- For 8205-E6D: (#ES78)
- Minimum required: 0
- Maximum allowed: 336 (Initial order maximum: 0)
- OS level required:
- Red Hat Enterprise Linux
- SUSE Linux Enterprise Server
- AIX supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#ES79) - 387GB SFF-2 SSD 5xx eMLC4 for IBM i
(No Longer Available as of March 31, 2018)
This SFF (2.5") SAS Solid State Drive (SSD) is shipped from IBM with 387 GB capacity formatted with 5xx (528) byte sectors. The drive is supported in SFF-2 SAS bays. CCIN is 5B16
- ES78 and ES79 are physically identical drives which have different feature codes to help the IBM configuration tools understand how the SSD is used. ES78 indicates usage by AIX, Linux or VIOS. ES79 indicates usage by IBM i.
- Limitation: Due to physical differences in the carrier/tray on which the drive is mounted, the SSD only fits in #5887/#EL1S EXP24S drawers (SFF-2). It does not fit in #5802/#5803 I/O drawers (SFF-1) or in POWER7 system units (SFF-1) or POWER8 system units (SFF-3) SAS bays. Also the drive was not tested with 512 byte sectors and thus JBOD mode for AIX/Linux is not supported. Note 4k and 5xx byte sector drives cannot be mixed in the same array. 4k drives can not be reformatted to 5xx drives (or vice versa).
- Attributes provided: one 387GB SFF-2 5xx SSD
- Attributes required: one SFF-2 SAS bay
- For 8205-E6D: (#ES79)
- Minimum required: 0
- Maximum allowed: 336 (Initial order maximum: 0)
- OS level required:
- IBM i 7.1 TR11 or later
- IBM i 7.2 TR4 or later
- IBM i 7.3 or later
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#ES7E) - 775GB SFF-2 SSD 5xx eMLC4 for AIX/Linux
(No Longer Available as of March 31, 2018)
This SFF (2.5") SAS Solid State Drive (SSD) is shipped from IBM with 775 GB capacity formatted with 5xx (528) byte sectors. The drive is supported in SFF-2 SAS bays. CCIN is 5B17
- ES7E and ES7F are physically identical drives which have different feature codes to help the IBM configuration tools understand how the SSD is used. ES7E indicates usage by AIX, Linux or VIOS. ES7F indicates usage by IBM i.
- Limitation: Due to physical differences in the carrier/tray on which the drive is mounted, the SSD only fits in #5887/#EL1S EXP24S drawers (SFF-2). It does not fit in #5802/#5803 I/O drawers (SFF-1) or in POWER7 system units (SFF-1) or POWER8 system units (SFF-3) SAS bays. Also the drive was not tested with 512 byte sectors and thus JBOD mode for AIX/Linux is not supported. Note 4k and 5xx byte sector drives cannot be mixed in the same array. 4k drives can not be reformatted to 5xx drives (or vice versa).
- Attributes provided: one 775GB SFF-2 5xx SSD
- Attributes required: one SFF-2 SAS bay
- For 8205-E6D: (#ES7E)
- Minimum required: 0
- Maximum allowed: 336 (Initial order maximum: 0)
- OS level required:
- Red Hat Enterprise Linux
- SUSE Linux Enterprise Server
- AIX supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#ES7F) - 775GB SFF-2 SSD 5xx eMLC4 for IBM i
(No Longer Available as of March 31, 2018)
This SFF (2.5") SAS Solid State Drive (SSD) is shipped from IBM with 775 GB capacity formatted with 5xx (528) byte sectors. The drive is supported in SFF-2 SAS bays. CCIN is 5B17
- ES7E and ES7F are physically identical drives which have different feature codes to help the IBM configuration tools understand how the SSD is used. ES7E indicates usage by AIX, Linux or VIOS. ES7F indicates usage by IBM i.
- Limitation: Due to physical differences in the carrier/tray on which the drive is mounted, the SSD only fits in #5887/#EL1S EXP24S drawers (SFF-2). It does not fit in #5802/#5803 I/O drawers (SFF-1) or in POWER7 system units (SFF-1) or POWER8 system units (SFF-3) SAS bays. Also the drive was not tested with 512 byte sectors and thus JBOD mode for AIX/Linux is not supported. Note 4k and 5xx byte sector drives cannot be mixed in the same array. 4k drives can not be reformatted to 5xx drives (or vice versa).
- Attributes provided: one 775GB SFF-2 5xx SSD
- Attributes required: one SFF-2 SAS bay
- For 8205-E6D: (#ES7F)
- Minimum required: 0
- Maximum allowed: 336 (Initial order maximum: 0)
- OS level required:
- IBM i 7.1 TR11 or later
- IBM i 7.2 TR4 or later
- IBM i 7.3 or later
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#ESA1) - PCIe2 RAID SAS Adapter Dual-port 6 Gb
(No Longer Available as of December 31, 2016)
The PCIe2 RAID SAS Adapter Dual-port 6 Gb is a high performance SSD controller using PCIe Gen2 technology. HDD are not supported. The adapter does not have write cache and thus pairing with another PCIe RAID SAS Adapter (#ESA1 or #ESA2) is optional. Pairing can provide controller redundancy and enhance performance. There are no batteries in the adapter to maintain.
The adapter provides two Mini-SAS HD (high density) connectors for the attachment of SSD located in the #5887 EXP24S or #5802/5803 12X PCIe I/O drawers. X, YO or AT SAS cables with HD connectors are used to attach to these drawers. A max of 18, 26 or 24 SSD can be controlled depending on the I/O drawers being used. A maximum of one drawer can be controlled. The #5802 12X PCIe I/O drawer has a max of 18. The #5803 PCIe I/O Drawer has a max of 26. The #5887 EXP24S Drawer has a max of 24. If controlling SSD in a #5802/5803 the adapter or at least one of an adapter pair must be located in that #5802/5803.
The 69 GB SSD features are not supported.
A single adapter provides RAID 0, RAID 5, RAID 6 and RAID 10 for AIX and Linux and VIOS. A pair of adapters (dual adapters) provide RAID 0, RAID 5, RAID 6 and RAID 10 for AIX and Linux and VIOS (not JBOD). The adapter provides RAID 5 and RAID 6 for IBM i. IBM i provides both OS mirroring and data spreading. AIX/Linux/VIOS provide OS mirroring (LVM).
Feature #ESA1 and #ESA2 are electrically identical and have the same CCIN of 57B4. ESA1 indicates a full high tail stock and ESA2 indicates a low profile tail stock.
Limitation: 4k byte sector HDD/SSD are not supported. Only 5xx byte sector drives are supported on this generation of PCIe adapter.
- Attributes provided: High performance SSD SAS adapter without write cache and with optional pairing
- Attributes required: One PCIe Gen2 slot in system unit or one PCIe Gen1 slot in #5802/ 5803 I/O drawer
- For 8205-E6D: (#ESA1)
- Minimum required: 0
- Maximum allowed: 42 (Initial order maximum: 42)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note:
- Maximum of 2 supported in the CEC.
- System maximum of 42 with 2 in the CEC and 40 in 4 x #5802/#5877.
(#ESA2) - PCIe2 LP RAID SAS Adapter Dual-port 6Gb
(No Longer Available as of December 31, 2016)
The PCIe2 RAID SAS Adapter Dual-port 6Gb is a high performance SSD controller using PCIe Gen2 technology. HDD are not supported. The adapter does not have write cache and thus pairing with another PCIe RAID SAS Adapter (#ESA1 or #ESA2) is optional. Pairing can provide controller redundancy and enhance performance. There are no batteries in the adapter to maintain.
The adapter provides two Mini-SAS HD (high density) connectors for the attachment of SSD located in the #5887 EXP24S or #5802/5803 12X PCIe I/O drawers. X, YO or AT SAS cables with HD connectors are used to attach to these drawers. A max of 18, 26 or 24 SSD can be controlled depending on the I/O drawers being used. A maximum of one drawer can be controlled. The #5802 12X PCIe I/O drawer has a max of 18. The #5803 PCIe I/O Drawer has a max of 26. The #5887 EXP24S Drawer has a max of 24. If controlling SSD in a #5802/5803 the adapter or at least one of an adapter pair must be located in that #5802/5803.
The 69GB SSD features are not supported.
A single adapter provides RAID 0, RAID 5, RAID 6 and RAID 10 for AIX and Linux and VIOS. A pair of adapters (dual adapters) provide RAID 0, RAID 5, RAID 6 and RAID 10 for AIX and Linux and VIOS (not JBOD). The adapter provides RAID 5 and RAID 6 for IBM i. IBM i provides both OS mirroring and data spreading. AIX/Linux/VIOS provide OS mirroring (LVM).
Feature #ESA1 and #ESA2 are electrically identical and have the same CCIN of 57B4. ESA1 indicates a full high tail stock and ESA2 indicates a low profile tail stock.
- Attributes provided: High performance SSD SAS adapter without write cache and with optional pairing
- Attributes required: One PCIe Gen2 slot in system unit or one PCIe Gen1 slot in #5802/ 5803 I/O drawer
- For 8205-E6D: (#ESA2)
- Minimum required: 0
- Maximum allowed: 2 (Initial order maximum: 2)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ESA3) - PCIe2 1.8GB Cache RAID SAS Adapter Tri-port 6Gb CR
(No Longer Available as of December 31, 2016)
The PCIe2 1.8 GB Cache RAID SAS Adapter Tri-port 6 Gb provides high performance HDD or SSD controller function using PCIe Gen2 technology. HDD and SSD can be either SFF or 3.5-inch drives (or both). A pair of #ESA3 adapters are required to provide mirrored write cache data and adapter redundancy. Integrated flash memory provides protection of the write cache without batteries in case of power failure.
The #ESA3 provides three Mini-SAS HD (high density) connectors for the attachment of SAS drives located in the #5887 EXP24S, #5886 EXP12S, or #5802 12X PCIe I/O drawers. X, YO or AT SAS cables with HD connectors are used to attach to these drawers. A max of 3 EXP24S or 6 EXP12S can be attached. If controlling drives in a #5802, at least one of #ESA3 pair must be located in that #5802. If not controlling drives in a #5802, the adapters can be placed in any PCIe slot which supports their use and the PCIe slots can be in different enclosures. An AA SAS cable with HD connectors is attached to the #ESA3 pair to communicate status and cache content information and is required unless all three ports are being used to attach I/O drawers.
The #ESA3 provides RAID 0, RAID 5, RAID 6 and RAID 10 for AIX and Linux and VIOS. The adapter provides RAID 5 and RAID 6 for IBM i. IBM i provides both OS mirroring and data spreading. AIX/Linux/VIOS provide OS mirroring (LVM). The CCIN = 57BB for this adapter.
#ESA3 is a refreshed version of the #5913 PCIe2 adapter offering the same function and performance, but with lower energy consumption.
Limitations:
- Cannot be paired with feature 5913
- Cannot be used with non-paired feature 5924
- 4k byte sector HDD/SSD are not supported. Only 5xx byte sector drives are supported on this generation of PCIe adapter
- Attributes provided: PCIe2 1.8 GB Cache RAID SAS Adapter
- Attributes required: One PCIe slot per adapter and Mini-SAS HD connector SAS cables
- For 8205-E6D: (#ESA3)
- Minimum required: 0
- Maximum allowed: 34 (Initial order maximum: 34)
- OS level required:
- AIX V7.1 with the 7100-03 Technology Level or later
- AIX V6.1 with the 6100-09 Technology Level or later
- AIX V7.1 with the 7100-02 Technology Level and Service Pack 4 or later
- AIX V7.1 with the 7100-01 Technology Level and Service Pack 9 or later
- AIX V6.1 with the 6100-08 Technology Level and Service Pack 4 or later
- AIX V6.1 with the 6100-07 Technology Level and Service Pack 9 or later
- AIX V5.3 with the 5300-12 Technology Level and Service Pack 9 or later
- IBM i 6.1 with machine code 6.1.1
- IBM i 7.1 or later
- Red Hat Enterprise Linux 5.7 or later
- Red hat enterprise Linux 6.1 or later
- SUSE Linux Enterprise Server 10 Service Pack 4 or later
- SUSE Linux Enterprise Server 11 Service Pack 2 or later
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
Note: Assignment to the VIOS requires VIOS 2.2.3.0 or later.
(#ESC0) - S&H - No Charge
(No Longer Available as of November 30, 2015)
No charge shipping and handling
- Attributes provided: None
- Attributes required: Sales Preapproval Required
- For 8205-E6D: (#ESC0)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: Does not apply
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#ESC6) - S&H-b
(No Longer Available as of November 30, 2015)
Shipping and handling
- For 8205-E6D: (#ESC6)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#ESD0) - 1.1TB 10K RPM SAS SFF-1 Disk Drive (IBM i)
1.14TB SFF 10K RPM SAS disk drive in Gen1 carrier. Supported in SFF-1 SAS bays such as provided in most POWER7 system units or the #5802/ 5803 I/O drawers. Disk is formatted for 528 byte sectors.
The drive can be reformatted to 512 byte sectors and used by AIX/ Linux/VIOS.
Limitation: can not be used in #5887 EXP24S Gen2 I/O drawer due to physical difference in Gen1 and Gen2 carriers.
- Attributes provided: 1.14TB 10K RPM 2.5-inch SAS disk drive mounted on Gen-1 carrier (SFF-1)
- Attributes required: one SFF-1 SAS bay
- For 8205-E6D: (#ESD0)
- Minimum required: 0
- Maximum allowed: 80 (Initial order maximum: 80)
- OS level required:
- IBM i 7.1, or later
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ESD1) - 1.2TB 10K RPM SAS SFF-1 Disk Drive (AIX/Linux)
(No Longer Available as of March 31, 2018)
1.20TB SFF 10K RPM SAS disk drive in Gen1 carrier. Supported in SFF-1 SAS bays such as provided in most POWER7 system units or the #5802/5803 I/O drawers. Disk is formatted for 512 byte sectors.
The drive can be reformated to 528 byte sectors and used by AIX/ IBM i/Linux/VIOS.
Limitation: can not be used in #5887 EXP24S Gen2 I/O drawer due to physical difference in Gen1 and Gen2 carriers.
- Attributes provided: 1.20TB 10K RPM 2.5-inch SAS disk drive mounted on Gen-1 carrier (SFF-1)
- Attributes required: one SFF-1 SAS bay
- For 8205-E6D: (#ESD1)
- Minimum required: 0
- Maximum allowed: 80 (Initial order maximum: 80)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Red Hat Enterprise Linux 5.8 for Power, or later
- Red Hat Enterprise Linux 6.2 for Power, or later
- SUSE Linux Enterprise 10, Service Pack 4, or later
- SUSE Linux Enterprise 11, Service Pack 2, or later
- IBM i - not supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ESD2) - 1.1TB 10K RPM SAS SFF-2 Disk Drive (IBMi)
(No Longer Available as of March 31, 2018)
1.14TB SFF 10K RPM SAS disk drive in Gen2 carrier. Supported in SFF-2 SAS bays such as provided in #5887 EXP24S I/O drawer. CCIN is 59CD. Disk is formatted for 528 byte sectors.
The drive can be reformatted to 512 byte sectors and used by AIX/ Linux/VIOS
Limitation: cannot be used in #5802/5803 I/O drawers or in CEC bays due to physical difference in Gen1 and Gen2 carriers.
- Attributes provided: 1.14TB 10K RPM 2.5-inch SAS disk drive mounted on Gen-2 carrier (SFF-2)
- Attributes required: one SFF-2 SAS bay in EXP24S drawer
- For 8205-E6D: (#ESD2)
- Minimum required: 0
- Maximum allowed: 336 (Initial order maximum: 250)
- OS level required:
- AIX - not supported
- Linux - not supported
- IBM i 7.1, or later
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ESD3) - 1.2TB 10K RPM SAS SFF-2 Disk Drive (AIX/Linux)
(No Longer Available as of March 31, 2018)
1.20TB SFF 10K RPM SAS disk drive in Gen2 carrier. Supported in SFF-2 SAS bay such as used in the #5887 EXP24S I/O drawer. Disk is formatted for 512 byte sectors as shipped from IBM Manufacturing. CCIN is 59CD.
The drive can be reformatted to 528 byte sectors and used by AIX/ IBM i/Linux/VIOS.
Limitations: physical difference in Gen1 and Gen2 carriers prevent usage in SFF-1 bays such as used in the #5802/5803 I/O drawer
- Attributes provided: 1.20TB 10K RPM 2.5-inch SAS disk drive mounted on Gen-2 carrier (SFF-2)
- Attributes required: one SFF-2 SAS bay in EXP24S drawer
- For 8205-E6D: (#ESD3)
- Minimum required: 0
- Maximum allowed: 336 (Initial order maximum: 250)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Red Hat Enterprise Linux 5.8 for Power, or later
- Red Hat Enterprise Linux 6.2 for Power, or later
- SUSE Linux Enterprise 10, Service Pack 4, or later
- SUSE Linux Enterprise 11, Service Pack 2, or later
- IBM i - not supported, use VIOS
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ESDJ) - 571GB 15K RPM SAS SFF-1 Disk Drive - 528 Block (IBM i)
(No Longer Available as of March 31, 2018)
2.5-inch (Small Form Factor (SFF)) 15k RPM SAS disk drive mounted in a Gen-1 carrier and supported in SAS SFF-1 bays. With 512 byte sectors (JBOD) drive capacity is 600GB. With 528 byte sectors (RAID) drive capacity is 571GB and the drive has additional data integrity protection. #ESDJ and #ESDK are physically identical drives with the same CCIN. However, IBM Manufacturing always formats the #ESDJ with 528 byte sectors. Depending on how the drive is ordered, IBM Manufacturing will ship #ESDK with either 512 or 528 byte formatting. Reformatting a disk drive can take significant time, especially on larger capacity disk drives.
- Attributes provided: One 571GB SFF SAS disk drive in Gen-1 carrier/ tray (SFF-1)
- Attributes required: Available Gen-1 drive bay (SFF-1) in POWER7 system unit or 12X-attached PCIe expansion drawer such as a #5802/5803
- For 8205-E6D: (#ESDJ)
- Minimum required: 0
- Maximum allowed: 80 (Initial order maximum: 80)
- OS level required:
- IBM i 7.1 TR8 and 7.2 or later supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ESDK) - 600GB 15K RPM SAS SFF-1 Disk Drive - 5xx Block (AIX/Linux)
(No Longer Available as of March 31, 2018)
2.5-inch (Small Form Factor (SFF)) 15k RPM SAS disk drive mounted in a Gen-1 carrier and supported in SAS SFF-1 bays. With 512 byte sectors (JBOD) drive capacity is 600GB. With 528 byte sectors (RAID) drive capacity is 571GB and the drive has additional data integrity protection. #ESDJ and #ESDK are physically identical drives with the same CCIN. However, IBM Manufacturing always formats the #ESDJ with 528 byte sectors. Depending on how the drive is ordered, IBM Manufacturing will ship #ESDK with either 512 or 528 byte formatting. Reformatting a disk drive can take significant time, especially on larger capacity disk drives.
- Attributes provided: One 600GB (571GB with 528 byte sectors) SFF SAS disk drive in Gen-1 carrier/ tray (SFF-1)
- Attributes required: Available Gen-1 drive bay (SFF-1) in POWER7 system unit or 12X-attached PCIe expansion drawer such as a #5802/5803
- For 8205-E6D: (#ESDK)
- Minimum required: 0
- Maximum allowed: 80 (Initial order maximum: 80)
- OS level required:
- AIX 6.1 and 7.1 or later supported
- IBM i not supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ESDN) - 571GB 15K RPM SAS SFF-2 Disk Drive - 528 Block
(No Longer Available as of March 31, 2018)
2.5-inch (Small Form Factor (SFF)) 15k RPM SAS disk drive mounted in a Gen-2 carrier and supported in SAS SFF-2 bays. With 512 byte sectors (JBOD) drive capacity is 600GB. With 528 byte sectors (RAID) drive capacity is 571GB and the drive has additional data integrity protection. #ESDN and #ESDP are physically identical drives with the same CCIN. However, IBM Manufacturing always formats the #ESDN with 528 byte sectors. Depending on how the drive is ordered, IBM Manufacturing will ship #ESDP with either 512 or 528 byte formatting. Reformatting a disk drive can take significant time, especially on larger capacity disk drives.
- Attributes provided: One 571GB SFF SAS disk drive in Gen-2 carrier/ tray (SFF-2)
- Attributes required: Available Gen-2 drive bay (SFF-2) in EXP24S drawer (such as #5887)
- For 8205-E6D: (#ESDN)
- Minimum required: 0
- Maximum allowed: 336 (Initial order maximum: 250)
- OS level required:
- IBM i 7.1 TR8 and 7.2 or later supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ESDP) - 600GB 15K RPM SAS SFF-2 Disk Drive - 5xx Block
(No Longer Available as of March 31, 2018)
2.5-inch (Small Form Factor (SFF)) 15k RPM SAS disk drive mounted in a Gen-2 carrier and supported in SAS SFF-2 bays. With 512 byte sectors (JBOD) drive capacity is 600GB. With 528 byte sectors (RAID) drive capacity is 571GB and the drive has additional data integrity protection. #ESDN and #ESDP are physically identical drives with the same CCIN. However, IBM Manufacturing always formats the #ESDN with 528 byte sectors. Depending on how the drive is ordered, IBM Manufacturing will ship #ESDP with either 512 or 528 byte formatting. Reformatting a disk drive can take significant time, especially on larger capacity disk drives.
- Attributes provided: One 600GB (571GB with 528 byte sectors) SFF SAS disk drive in Gen-2 carrier/ tray (SFF-2)
- Attributes required: Available Gen-2 drive bay (SFF-2) in EXP24S drawer (such as #5887)
- For 8205-E6D: (#ESDP)
- Minimum required: 0
- Maximum allowed: 336 (Initial order maximum: 250)
- OS level required:
- Red Hat Enterprise Linux
- SUSE Linux Enterprise Server
- AIX 6.1 and 7.1 or later supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#ESR2) - Six ES02 387GB 1.8" SAS SSD for AIX/Linux with eMLC
(No Longer Available as of February 27, 2015)
Quantity 6 of feature ES02
- Attributes provided: Six 387GB Solid State Drive
- Attributes required: 6 SSD bays in EXP30
- For 8205-E6D: (#ESR2)
- Minimum required: 0
- Maximum allowed: 20 (Initial order maximum: 20)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- SUSE Linux supported
- Red Hat Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: No
(#ESR4) - Six ES04 387GB 1.8" SAS SSD for IBM i with eMLC
(No Longer Available as of February 27, 2015)
387GB 1.8" SAS SSD for IBM i with eMLC This Solid State Drive (SSD) is shipped from IBM with 528-byte sector RAID formatting to provide 387 GB capacity for AIX/IBM i/ Linux. It is placed in a 1.8" SAS bay of the EXP30 Ultra SSD I/O Drawer.
Feature #ES02 and #ES04 are physically identical and have the same CCIN = 58BB, but two features are used to allow IBM configurator tools to understand usage by either AIX/Linux/VIOS or IBM i. #EL34 indicates AIX/Linux/VIOS usage. ESR4/ES04 indicates IBM i usage. Enterprise Multi-Level Cell (eMLC) technology is used to provide extremely reliable, cost effective, dense SSD storage.
Limitation: Drive was not tested with 512 byte sectors and thus JBOD mode for AIX/Linux is not supported
- Attributes provided: 387GB SATA Solid State Drive
- Attributes required: None
- For 8205-E6D: (#ESR4)
- Minimum required: 0
- Maximum allowed: 10 (Initial order maximum: 10)
- OS level required:
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: No
(#ESRA) - Four ES0A 387GB SFF-1 SSD for AIX/Linux with eMLC
Quantity 4 of feature ES0A.
- Attributes provided: Four 387GB SFF-1 SSD formatted with 528 byte formatting
- Attributes required: Four SFF-1 SAS bays
- For 8205-E6D: (#ESRA)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- SUSE Linux supported
- Red Hat Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: No
(#ESRB) - Four ES0B 387GB SFF-1 SSD for IBM i with eMLC
Quantity 4 of feature ES0B
- Attributes provided: Four 387GB SFF-1 SSD with 528 byte formatting
- Attributes required: Four SFF-1 SAS bays
- For 8205-E6D: (#ESRB)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: No
(#ESRC) - Four ES0C 387GB SFF-2 SSD for AIX/Linux with eMLC
Quantity 4 of feature ES0C
- Attributes provided: Four 387GB SFF-2 SSD formatted with 528 byte formatting
- Attributes required: Four SFF-2 SAS bays
- For 8205-E6D: (#ESRC)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- SUSE Linux supported
- Red Hat Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: No
(#ESRD) - Four ES0D 387GB SFF-2 SSD for IBM i with eMLC
Quantity 4 of feature ES0D
- Attributes provided: Four 387GB SFF-2 SSD formatted with 528 byte formatting
- Attributes required: Four SFF-2 SAS bays
- For 8205-E6D: (#ESRD)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: No
(#ESRE) - Four ES10 387GB SFF-1 SSD for AIX/Linux
(No Longer Available as of November 30, 2015)
Quantity 4 of feature ES10.
- Attributes provided: Four 387GB SFF-1 SSD formatted with 528 byte sectors
- Attributes required: Four SFF-1 SAS bays
- For 8205-E6D: (#ESRE)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- IBM i - not supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#ESRF) - Four ES11 387GB SFF-1 SSD for IBM i
(No Longer Available as of November 30, 2015)
Quantity 4 of feature ES11
- Attributes provided: Four 387GB SFF-1 SSD formatted with 528 byte sectors
- Attributes required: Four SFF-1 SAS bays
- For 8205-E6D: (#ESRF)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 7.1, or later
- IBM i 6.1 with machine code 6.1.1, or later
- AIX - not supported
- Linux - not supported
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#ESRG) - Four ES19 387GB SFF-2 SSD for AIX/Linux
(No Longer Available as of November 30, 2015)
Quantity 4 of feature ES19.
- Attributes provided: Four 387GB SFF-2 SSD formatted with 528 byte sectors
- Attributes required: Four SFF-2 SAS bays in EXP24S drawer
- For 8205-E6D: (#ESRG)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- Linux supported
- IBM i - not supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#ESRH) - Four ES1A 387GB SFF-2 SSD for IBM i
(No Longer Available as of November 30, 2015)
Quantity 4 of feature ES1A.
- Attributes provided: Four 387GB SFF-2 SSD formatted with 528 byte sectors
- Attributes required: Four SFF-2 SAS bays in EXP24S drawer
- For 8205-E6D: (#ESRH)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 7.1, or later
- IBM i 6.1 with machine code 6.1.1, or later
- AIX - not supported
- Linux - not supported
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#EU01) - 1TB Removable Disk Drive Cartridge
1TB Removable Disk Drive Cartridge (#EU01) provides a RDX disk drive in a rugged cartridge to be used in an RDX Internal and External Docking Station such as the (#1103, #1104 or #1123, #EU03, #EU04, #EU23, or #EU07 1TB is uncompressed. docking station. 1TB is uncompressed. Compression/decompression is provided by the operating system, not the drive itself. Feature EU01 is not entitled under the IBM Maintenance Agreement, if one is purchased.
- Attributes provided: 1TB RDX rugged disk cartridge
- Attributes required: RDX docking station
- For 8205-E6D: (#EU01)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required:
- See RDX Docking Station
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EU03) RDX USB Internal Docking Station for Removable Disk Cartridge
USB Internal Docking Station accommodates RDX removable disk cartridge of any capacity. The disk are in a protective rugged cartridge enclosure that plug into the docking station. The docking station holds one removable rugged disk drive/cartridge at a time. The rugged removable disk cartridge and docking station provides saves, restores and backs up similar to tape drive. This can be an excellent alternative to DAT72, DAT160, 8mm, and VXA-2 and VXA-320 tapes. The drive is controlled by an internal USB port in the system unit. CCIN: 632C-0D4
#EU03 is a follow on product to the #1103 RDX docking station. #EU03 has identical function and performance to the external #EU04 RDX docking station.
#EU03 is controlled by an internal USB port in the system unit.
- Attributes provided: USB RDX Internal Docking Station
- Attributes required: Available HH bay and at least one Removable Disk Drive Cartridge such as the #EU01, #1107 or #EU08.
- For 8205-E6D: (#EU03)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 7.1 supported
- SUSE Linux supported
- Red Hat Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EU04) RDX USB External Docking Station for Removable Disk Cartridge
(No Longer Available as of July 26, 2016)
Note: Feature EU04 is withdrawn in the following European countries: Belgium, Luxembourg, Netherlands, Germany, Austria, Liechtenstein, France, Italy, Denmark, Sweden, Norway, Finland, Iceland, Spain, Portugal, Greece, Cyprus, Malta, United Kingdom, Ireland, Bulgaria, Croatia, Hungary, Romania, Slovenia, Czech Republic, Slovakia, Estonia, Latvia, Lithuania, and Poland.
USB Eternal Docking Station accommodates RDX removable disk cartridge of any capacity. The disk are in a protective rugged cartridge enclosure that plug into the docking station. The docking station holds one removable rugged disk drive/cartridge at a time. The rugged removable disk cartridge and docking station backs up similar to tape drive. This can be an excellent alternative to DAT72, DAT160, 8mm, and VXA-2 and VXA-320 tapes. CCIN: 632C-0D4
#EU04 is a follow on product to the #1104 RDX docking station. #EU04 has identical function and performance to the internal #EU03 RDX docking station.
- Attributes provided: USB RDX External Docking Station, 3M USB cable, 1M power cord with universal adapter 100-240 VAC, 50-60Hz input providing 15W DC to the docking station.
- Attributes required: One USB port and at least one #1106, #1107, #EU01, #EU08, #EU15, or follow-on Removable Disk Drive Cartridge
- For 8205-E6D: (#EU04)
- Minimum required: 0
- Maximum allowed: 5 (Initial order maximum: 5)
- OS level required:
- IBM i 7.1 supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EU07) RDX SATA Internal Docking Station for Removable Disk Cartridge
(No Longer Available as of March 8, 2016)
SATA Internal Docking Station accommodates RDX removable disk cartridge of any capacity. The disk are in a protective rugged cartridge enclosure that plug into the docking station. The docking station holds one removable rugged disk drive/cartridge at a time. The rugged removable disk cartridge and docking station backs up similar to tape drive. This can be an excellent alternative to DAT72, DAT160, 8mm, and VXA-2 and VXA-320 tapes. CCIN: 632C-0D4
Note the SATA RDX docking station is functionally identical to the USB RDX docking station.
The SATA interface is controlled by internal SAS/SATA controller of the system unit.
- Attributes provided: SATA Internal Docking Station
- Attributes required: Available HH bay and at least one #EU01, #1107 or #EU08 Removable Disk Drive Cartridge.
- For 8205-E6D: (#EU07)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- IBM i 6.1 supported
- IBM i 7.1 supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EU08) - RDX 320 GB Removable Disk Drive
(No Longer Available as of November 30, 2015)
Provides a RDX disk drive in a rugged cartridge to be used in an RDX docking station such as #EU03, #EU04, #EU23, #1123, #1103, #1104 or #EU07. Capacity is 320 GB is uncompressed. Compression/ decompression is provided by the operating system, not the drive itself. Feature EU08 is not entitled under the IBM Maintenance Agreement, if one is purchased.
- Attributes provided: 320 GB RDX rugged disk/cartridge
- Attributes required: One docking station
- For 8205-E6D: (#EU08)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required:
- See RDX Docking Station
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EU11) - 2.5/6.25TB LTO-6 SAS Tape Drive, Half-high
This SAS tape drive is located in the HH bay of the supporting system units and run by the integrated SAS controller in those system units. A SAS cable feature code such as #3656 or #3657 is required for the drive's attachment inside the system unit.
The drive uses industry standard Ultrium media. This drive will Write/Read Ultrium6 (LTO-6), Write/Read Ultrium5 (LTO-5) and Read Ultrium4 (LTO-4) formats. With LTO-6 media, it has capacity of 2.5 TB native or 6.25 TB with typical compression. Compression capability is built into the drive hardware. Both write many and write once (WORM) cartridges are supported.
The drive uses linear technology and operates in streaming mode. The data transfer rate is 160 MB/sec with LTO-6 media. Data transfer rates are slower using LTO-5 or LTO-4 media. To enhance overall operational performance and to minimize normal head wear, matching down speed capability is supported down to 40 MB/s.
Limitation: #EU11 encryption is not natively supported by AIX or IBM i, but is supported by the drive hardware using user provided applications in an AIX environment.
- Attributes provided: one HHLTO-6 SAS Tape Drive, one LTO-6 Cleaning Cartridge, and one LTO-6 Test Cartridge.
- Attributes required: One 1.6-inch (41mm) half-high media bay, One SAS cable
- For 8205-E6D: (#EU11)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported
- IBM i 7.1 supported
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EU15) - 1.5TB Removable Disk Drive Cartridge
(No Longer Available as of November 30, 2015)
The 1.5 TB Removable Disk Drive Cartridge provides a RDX disk drive in a rugged cartridge to be used in an RDX Internal and External Docking Station such as (#1103, #1104 or #1123, #EU03, #EU04, #EU23, or #EU07. 1.5TB is uncompressed. Compression/ decompression is provided by the operating system, not the drive itself. Feature EU015 is not entitled under the IBM Maintenance Agreement, if one is purchased.
- Attributes provided: 1.5TB RDX rugged disk cartridge
- Attributes required: RDX docking station
- For 8205-E6D: (#EU15)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: See Docking station for OS requirements
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EU16) - 80/160GB DAT160 USB Tape Drive
(No Longer Available as of February 14, 2014)
The Internal Tape Drive is a 5.25-inch, half-high for save/ restore and archive functions. This DDS Gen6 tape drive uses the larger IBM DAT160 and 4-mm data cartridges and is compression capable, providing a capacity of up to 160 GB (assuming 2:1 compression ratio).
This drive attaches internally to the USB port of the console of the server (no visible external cable). The USB port on the console is not available for other connections when #EU16 is installed. This USB connection differs from SAS #5619 DAT160 Tape Drive which attaches to the integrated SAS adapter in the server. Thus the USB DAT160 helps avoid tape/disk bandwidth contention possible with a SAS DAT160 drive.
Characteristics
- Capacity: 80 GB native mode, 160 GB (typical) compression mode
- DDS Gen6
- Form Factor: 5.25-inch half high
- Media: IBM DAT160 and 4mm media
- Technology: Helical scan, rotating head
- Operation: Streaming
- Data Transfer Rate: 6MBps native mode,
- Interface: USB
- Compatibility: DDS4 (R/W), DAT72 (R/W) and DAT160 (R/W)
- Attributes provided: 4mm tape capability, Test Cartridge, and a Cleaning Cartridge
- Attributes required: One 1.6-inch (41mm) half-high media bay
- For 8205-E6D: (#EU16)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required:
- AIX Version 6.1 supported
- AIX Version 7.1 supported
- IBM i 6.1 supported -- VIOS required
- IBM i 7.1 supported -- VIOS required
- Linux supported
- Refer to Software Requirements for specific O/S levels supported
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EU17) - 2.5 TB LTO-6 Tape Cartridge
Removable LTO-6, 2.5 TB Cartridge capable of 6.25 TB compression.
- For 8205-E6D: (#EU17)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required:
- See RDX Disk Drive
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EU18) - 5-Pack of #EU17
5-pack of 2.5 TB LTO-6 Tape Cartridge (#EU17).
- For 8205-E6D: (#EU18)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required:
- See RDX Disk Drive
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EU19) - Cable Ties & Labels
(No Longer Available as of June 19, 2015)
Set of 10 hook and loop fabric, often called VELCRO(R), ties 35.5 cm (14-inch) in length to conveniently attach cables or cords to rack or other cables. Set of 16 labels 2x4 inches (5x10 cm) in sizes to identify cables when installing or moving or servicing equipment.
- For 8205-E6D: (#EU19)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 254)
- OS level required:
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EU24) - Cognos on Power - Small
(No Longer Available as of November 30, 2015)
Cognos on Power - Small (FC EU24): Defines
Note: Feature is not available in the Greater China Group, China-Offshore/on Shore, Hong Kong, Macao, Mongollia and Taiwan, Province of China.
- 710 (8231-E1D) 4 core 3.6Ghz processor and 48 GB memory.
- 720 (8202-E4D) 4 core 3.6Ghz processor and 48 GB memory.
- 730 (8231-E2D) 8 core 4.3Ghz processor and 48 GB memory.
- 740 (8205-E6D) 6 core 4.2GHz processor and 48 GB memory.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#EU24)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#EU25) - Cognos on Power - Large
(No Longer Available as of November 30, 2015)
Cognos on Power - Large (FC EU25): Defines
Note: Feature is not available in the Greater China Group, China-Offshore/on Shore, Hong Kong, Macao, Mongollia and Taiwan, Province of China.
- 710 (8231-E1D) 4 core 3.6Ghz processor and 64 GB memory.
- 720 (8202-E4D) 4 core 3.6Ghz processor and 64 GB memory.
- 730 (8231-E2D) 8 core 4.3Ghz processor and 64 GB memory.
- 740 (8205-E6D) 6 core 4.2GHz processor and 64 GB memory.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#EU25)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#EU28) - 25th Anniversary Edition
(No Longer Available as of September 20, 2013)
Feature EU28 specifies IBM i 25th Anniversary Edition supported when IBM i Solution Edition #4927 or #4928 or #4929 is added to the configuration on selected servers starting on IBM i anniversary June 21, 2013.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#EU28)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#EU29) - Order Placed Indicator
This feature is use to identify ORDER PLACED IN ALGERIA, COMOROS, OR TUNISIA for administrative purposes within manufacturing to Facilitate processing.
- Attributes provided: ORDER PLACED INDICATOR FOR ADMINISTRATIVE TRACKING
- Attributes required: None.
- For 8205-E6C: (#EU29)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: Does not apply
- For 8205-E6D: (#EU29)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: Does not apply
(#EU2T) - 2TB Removable Disk Drive Cartridge (RDX)
The 2.0TB Removable Disk Drive Cartridge provides a RDX disk drive in a rugged cartridge to be used in an RDX Internal and External Docking Station such as (#1103, #1104 or #1123, #EU03, #EU04, #EU23, or #EU07. 2.0TB is uncompressed. Compression/ decompression is provided by the operating system, not the drive itself. Feature EU2T is not entitled under the IBM Maintenance Agreement, if one is purchased.
- Attributes provided: 2.0TB RDX rugged disk cartridge
- Attributes required: RDX docking station
- For 8205-E6D: (#EU2T)
- Minimum required: 0
- Maximum allowed: 9999 (Initial order maximum: 250)
- OS level required: See docking station for OS requirements
- Initial Order/MES/Both/Supported: Both
- CSU: Yes
- Return parts MES: No
(#EUC0) - Software preload define
(No Longer Available as of November 30, 2015)
Communicates to the Customer Solution Center that no components of a given software product are to be preloaded.
- Attributes provided: Within a hardware and software solution, a define for software components.
- Attributes required: Hardware specify feature for the software product within a hardware and software solution.
- For 8205-E6D: (#EUC0)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#EUC1) - Software preload define
(No Longer Available as of November 30, 2015)
Communicates to the Customer Solution Center that a given component of a software product is to be preloaded. The name of the software component is defined by the configurator.
- Attributes provided: Within a hardware and software solution, a define for a software component.
- Attributes required: Hardware specify feature for the software product within a hardware and software solution.
- For 8205-E6D: (#EUC1)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#EUC2) - Software preload define
(No Longer Available as of November 30, 2015)
Communicates to the Customer Solution Center that a given component of a software product is to be preloaded. The name of the software component is defined by the configurator.
- Attributes provided: Within a hardware and software solution, a define for a software component.
- Attributes required: Hardware specify feature for the software product within a hardware and software solution.
- For 8205-E6D: (#EUC2)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#EUC3) - Software preload define
(No Longer Available as of November 30, 2015)
Communicates to the Customer Solution Center that a given component of a software product is to be preloaded. The name of the software component is defined by the configurator.
- Attributes provided: Within a hardware and software solution, a define for a software component.
- Attributes required: Hardware specify feature for the software product within a hardware and software solution.
- For 8205-E6D: (#EUC3)
- Minimum required: 0
- Maximum allowed: 1 (Initial order maximum: 1)
- OS level required: None
- Initial Order/MES/Both/Supported: Initial
- CSU: N/A
- Return parts MES: Does not apply
(#EUC6) - Core Use HW Feature
A Service Provider (SP) under a "revenue payment" contract with IBM pays IBM a percentage of revenue generated on their infrastructure used to deliver cloud services. The contract stipulates that each quarter the service provider calculates the amount due IBM and then purchases a quantity of features that satisfies the required payment. Each occurrence of this feature represents one billing unit.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#EUC6)
- Minimum required: 0
- Maximum allowed: 250 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
(#EUC7) - Core Use HW Feature 10X
A Service Provider (SP) under a "revenue payment" contract with IBM pays IBM a percentage of revenue generated on their infrastructure used to deliver cloud services. The contract stipulates that each quarter the service provider calculates the amount due IBM and then purchases a quantity of features that satisfies the required payment. Each occurrence of this feature represents one billing unit.
- Attributes provided: None
- Attributes required: None
- For 8205-E6D: (#EUC7)
- Minimum required: 0
- Maximum allowed: 250 (Initial order maximum: 0)
- OS level required: None
- Initial Order/MES/Both/Supported: MES
- CSU: Yes
- Return parts MES: No
|
|
| Accessories |
|
|
None.
Customer replacement parts
The following parts have been designated as Tier 1 CRUs:
- DASD Drive
- DVD Drive
- DASD Backplane
- Fan Air Baffle
- Fans
- All PCI Adapters
- Power Supply
- Adapter - GX ++
- Line/power cord
- Keyboard
- Mouse
- External cables
- Display
- Operator Panel
- TOD Battery
- Memory DIMMs
- Processor VRM
- SAS Conduit Cable
- Tape drive power/signal cable
- Interlock Switch
- RAID Battery
- RAID Battery Card
- RAID Package Card
- SPCN Cable
- Memory Riser Card
|
|
| Supplies |
|
|
None.
Supplemental media
Trademarks
(R), (TM), * Trademark or registered trademark of International Business Machines Corporation.
** Company, product, or service name may be a trademark or service mark of others.
Windows is a trademark of Microsoft Corporation.
UNIX is a registered trademark in the United States and other
countries licensed exclusively through X/Open Company Limited.
© IBM Corporation 2018.
Back to top