Family 9835+02 IBM FlashSystem A9000R

IBM United States Sales Manual
Revised:  May 08, 2018.

Table of contents
TOC Link Product life cycle dates TOC Link Technical description
TOC Link Abstract TOC Link Publications
TOC Link Highlights TOC Link Features
TOC Link Description TOC Link Accessories
TOC Link Models TOC Link Supplies

 
Product life cycle dates
Type Model Announced Available Marketing Withdrawn Service Discontinued
9835-425 2017/10/242017/11/24 - -

Back to topBack to top
 
Abstract

Enterprises looking to gain a competitive advantage need IT solutions with less complexity, easier scalability, and better data economics. The IBM FlashSystem A9000R delivers the microsecond latency and high availability of IBM FlashCore technology with grid architecture, simple scalability, and industry-leading IBM software to meet the needs of today's businesses. Comprehensive data reduction capabilities, including pattern removal, deduplication, and compression, help lower total cost of ownership, while a new, highly intuitive user interface simplifies management. IBM FlashSystem A9000R transforms technology infrastructure into business innovation.

Model 425 for IBM FlashSystem A9000 delivers improved cost, scale, and density, utilizing the latest 3D-TLC NAND flash technology.

Model abstract 9835-425

The IBM 9835 Model 425 is the IBM FlashSystem A9000R with a one-year warranty. It delivers the microsecond latency and high availability of IBM FlashCore technology with grid architecture, simple scalability, and industry-leading IBM software to meet the needs of today's businesses. Comprehensive data reduction capabilities, including pattern removal, deduplication, and compression, help lower total cost of ownership, while a new, highly intuitive user interface simplifies management. IBM FlashSystem A9000R transforms technology infrastructure into business innovation.
Back to topBack to top
 

Highlights

IBM FlashSystem A9000R is a grid-scale, all-flash storage platform designed to bring your business into the cognitive era.

  • Accelerate data at scale with the extreme performance of grid architecture and IBM FlashCore technology
  • Optimize storage economics with inline pattern removal, deduplication, and enhanced compression
  • Meet your diverse workload requirements with a choice of performance and capacity configurations
  • Scale resources linearly to meet cloud, analytics, and cognitive business requirements
  • Eliminate application silos and consolidate with an integrated rack solution that can scale to support massive mixed workloads
  • Leverage the A9000R interoperability with IBM XIV Gen3 and protect A9000R data at lower cost by replicating to XIV Gen3
  • Adopt cloud economics and agility with A9000R solutions for Kubernetes container environments, as well as IBM Cloud Private, VMware, OpenStack, and Microsoft environments, at no additional cost
  • Support multitenant clouds with enterprise-grade high availability, security, and quality-of-service (QoS) features that prevent noisy neighbors

Back to topBack to top
 
Description

The future of your business will depend on how well you leverage data assets to capture or maintain competitive advantage. Deeper insights from data will require better information technology and you will need a data storage system that can keep pace with highly virtualized environments, cloud computing, mobile and social systems of engagement, and in-depth, real-time analytics.

IBM FlashSystem A9000R delivers the consistent, reliable, efficient performance needed for dynamic data at scale. Large enterprises looking to gain a competitive advantage need IT solutions with less complexity, easier scalability, and better data economics. IBM FlashSystem A9000R meets these needs. It integrates the microsecond latency and high availability of IBM FlashCore technology with grid architecture, comprehensive data reduction, and industry-leading IBM software. IBM FlashSystem A9000R transforms technology infrastructure into business innovation.

Consistent, extreme speed for data at scale

IBM FlashSystem A9000R is an excellent platform for industry leaders with rapidly growing cloud storage and mixed workload environments. IBM software-defined storage capabilities and IBM FlashCore technology combine to produce the extreme performance and scalability required in enterprise-class storage solutions. IBM FlashSystem A9000R aggregates grid elements (each containing two grid controllers and one flash enclosure) within a 42U integrated rack solution. The combination of grid architecture and flash storage media delivers consistent, predictable high performance and ultra-low latency, even under heavy workloads with full data reduction enabled. With grid architecture, the system maintains this performance autonomously by evenly distributing every workload's data across all the system resources, in real time. QoS features also help ensure that tenant service levels aren't compromised.

High-density, supreme data reduction economics

IBM FlashSystem A9000R utilizes IBM MicroLatency modules that leverage IBM-enhanced 3D-TLC flash to provide exceptional density, low latency, extremely high input/output (I/O) and greater reliability. IBM FlashSystem A9000R flash-optimized data reduction makes it optimal for large, mixed workload environments. Structured data workloads benefit from the system's inline data compression technology. Unstructured data workloads benefit from the system's inline data deduplication. Along with pattern removal and thin provisioning, these capabilities add up to enable extraordinarily high system capacity that can easily scale out to more than three petabytes in a single system.

High-availability

IBM FlashSystem A9000R delivers the confidence you require in your infrastructure with greater than 99.999% availability. The underlying IBM FlashCore technology provides enterprise-grade reliability and high availability with advanced flash management features, such as IBM Variable Stripe RAID, innovative IBM-engineered error correction codes, overprovisioning, and wear leveling. In addition, IBM FlashSystem A9000R includes built-in Spectrum Accelerate software to deliver redirect-on-write space-efficient snapshots, along with asynchronous and synchronous replication to enable granular data protection without increasing costs.

To deliver high availability levels that exceed the IBM FlashSystem A9000R 99.999% availability, the system embeds a native implementation of IBM HyperSwap capability, delivering active-active data access and transparent failover, per volume, across IBM FlashSystem A9000 and A9000R arrays, and across data centers.

Easy scalability for business on the move

IBM FlashSystem A9000R is a rack-based, grid-scale system designed to address the needs of enterprises with diverse and rapidly growing environments. It comes as a preconfigured solution to enable simplified deployment.

As an intuitive management interface, IBM Hyper-Scale Manager enables you to orchestrate private and hybrid multi-tenant cloud environments at very large scales. IBM Hyper-Scale Manager provides the ability to manage multiple IBM FlashSystem A9000R, IBM FlashSystem A9000, IBM XIV, and IBM Spectrum Accelerate solutions from a single pane of glass. Cross-generation, asynchronous replication between your A9000R systems and XIV Gen3 systems is simplified by the IBM Hyper-Scale Manager user-interface, enabling you to leverage your XIV Gen3 investment and lower the cost of data protection and disaster recovery. Hyper-Scale Mobility enables you to simply and nondisruptively consolidate XIV Gen3 systems into fewer IBM FlashSystem A9000R systems with minimal operational impacts. Multitenancy features simplify delegation and segregate storage-management access among storage administrators and tenants. QoS features help ensure that tenant service levels aren't compromised. These capabilities, paired with consistent high performance and optimized economics, make IBM FlashSystem A9000R the ideal storage platform for industry leaders.

Accessibility by people with disabilities

A US Section 508 Voluntary Product Accessibility Template (VPAT) containing details on accessibility compliance can be found on the IBM Accessibility website.
Back to topBack to top
 

Models

Model summary matrix

Model Description Used In Warranty
9835-425 IBM FlashSystem A9000R 42U rack 1-year
9837-425 IBM FlashSystem A9000R 42U rack 3-year

Customer setup (CSU)

No.

Devices supported

Information on servers, operating systems, host adapters, and connectivity products supported by FlashSystem products is available at the SSIC website.

Model conversions

Not available.
Back to topBack to top
 

Technical description
TOC Link Physical specifications TOC Link Operating environment TOC Link Limitations
TOC Link Hardware requirements TOC Link Software requirements


Physical specifications

  • Width: 644.4 mm (25.4 in.)
  • Depth: 1297 mm (51.1 in.)
  • Height: 2015 mm (79.3 in.)
  • Weight:
    • Entry configuration with two grid elements: 616 kg (1,358 lb)
    • Scaled out configuration with four grid elements: 774 kg (1,706 lb)

Operating environment

  • Temperature: 10C to 35C (50F to 95F)
  • Electrical power:
    • Voltage range: 200 - 240 V AC
    • Frequency: 50 - 60 Hz
  • Power consumption:
    • Two grid elements: 3.085KW / 3.418 kVA
    • Three grid elements: 4.540KW / 5.031 kVA
    • Four grid elements: 5.996KW / 6.644 kVA
  • Heat dissipation:
    • Two grid elements: 10.5 BTU per hour
    • Three grid elements: 15.8 BTU per hour
    • Four grid elements: 21 BTU per hour

Limitations

Not applicable.

Hardware requirements

Go to the IBM System Storage Interoperation Center (SSIC) for the latest hardware requirements and compatibility information.

Software requirements

Go to the IBM SSIC for the latest software requirements and compatibility information.
Back to topBack to top
 

Publications

No publications are shipped with the announced products.

To view online information and link to a download site on or after general availability date, go to the IBM FlashSystem A9000R website.

To order additional select hardcopy publications or download free PDF format publications, go to the IBM Publications Center website.

Call the Publications Support Group at 800-879-2755, and select option 1.

Contact your IBM representative.

The IBM Publications Center

Hardcopies of selected IBM FlashSystem A9000R publications are available from the IBM Publications Center, as well as free softcopy publications. The Publications Center is a worldwide central repository for IBM product publications and marketing material with a catalog of 70,000 items. Extensive search facilities are provided. A large number of publications are available online in various file formats, and they can all be downloaded.

To access the IBM Publications Center Portal, go to the IBM Publications Center website.

The Publications Center is a worldwide central repository for IBM product publications and marketing material with a catalog of 70,000 items. Extensive search facilities are provided. A large number of publications are available online in various file formats, which can currently be downloaded.
Back to topBack to top
 

Features
TOC Link Features - No charge TOC Link Features - Chargeable TOC Link Feature descriptions


Features - No charge

  • Administrative
    • (#AFAX) - Encryption Disable indicator
    • (#AFZA) - Cisco UCS Attachment Ind
    • (#AG00) - Shipping and Handling NC

Features - Chargeable

Special Features - Initial Orders

  • Grid Controllers
    • (#5005) - Grid controller with 4x 16G FC/FC-NVMe + 2x 10G iSCSI
  • Rack Related
    • (#AFR2) - Height Reduction
    • (#AFR3) - Weight Reduction
  • Power
    • (#1001) - Base 425
    • (#1011) - T42 Rack
  • Module
    • (#AFE4) - Flash Enclosure with 12 x 3.6TB MicroLatency modules
    • (#AFE5) - Flash Enclosure with 12 x 8.5TB MicroLatency modules
    • (#AFE6) - Flash Enclosure with 12 x 18TB MicroLatency modules
  • Miscellaneous
    • (#5003) - Grid controller with 4x 16G FC + 2x 10G iSCSI
    • (#5004) - Grid controller with 4x 10G iSCSI
  • Administrative
    • (#AG9L) - Chargeable Shipping and Handling

Special Features - Plant and/or Field Installable

  • Rack Related
    • (#AFR1) - Rear Water-Cooled Door
    • (#AFR5) - RFID Labeling
    • (#AFR6) - Door lock
  • Power
    • (#1020) - 1ph 60A PDUs
    • (#1025) - 3ph 60A PDUs, non-EMEA (delta)
    • (#1026) - 3ph 32A PDUs, EMEA (wye)
    • (#1052) - 3ph 60A pin cords (IEC309)
    • (#1053) - 3ph 32A hard wired EMEA wye
    • (#1054) - 1ph 60A pin cords (IEC309)
    • (#1055) - 1ph 60A hard wired
  • Power Cords
    • (#1056) - 3ph 32A pin cords (IEC309), EMEA (wye)
  • Cable
    • (#1073) - 4th Grid-Element Cable Bundle
    • (#5901) - Fiber optics (LC to LC)
    • (#5902) - Fiber optics (LC to SC)

Feature descriptions

Features for IBM FlashSystem A9000R (9835-425)

The following is a list of all feature codes in numeric order for the IBM System Storage 9835 machine type.

(#1001) - Base 425

This feature includes the base installation material and dual Infiniband switches required for the grid scale-out connectivity

  • For 9835-425: (#1001)
    • Minimum required: 1
    • Maximum allowed: 1 (Initial order maximum: 1)
    • Prerequisites: None
    • Corequisites: None
    • Compatibility conflicts: None
    • Customer setup: N/A
    • Limitations: None
    • Plant / Field installable: Initial
    • Cable order: None
    • Comments: None
(#1011) - T42 RackIBM T42 rack
  • For 9835-425: (#1011)
    • Minimum required: 1
    • Maximum allowed: 1 (Initial order maximum: 1)
    • Prerequisites: None
    • Corequisites: None
    • Compatibility conflicts: None
    • Customer setup: N/A
    • Limitations: None
    • Plant / Field installable: Initial
    • Cable order: None
    • Comments: None
(#1020) - 1ph 60A PDUs1ph 60A PDUs
  • For 9835-425: (#1020)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • Prerequisites: None
    • Corequisites: None
    • Compatibility conflicts: Cannot coexist with feature #1025 or #1026
    • Customer setup: Yes
    • Limitations: None
    • Plant / Field installable: Both
    • Cable order: None
    • Comments: None
(#1025) - 3ph 60A PDUs, non-EMEA (delta)

3ph 60A PDUs, non-EMEA (delta)

  • For 9835-425: (#1025)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • Prerequisites: None
    • Corequisites: None
    • Compatibility conflicts: Cannot coexist with feature #1020 or #1026
    • Customer setup: Yes
    • Limitations: None
    • Plant / Field installable: Both
    • Cable order: None
    • Comments: None
(#1026) - 3ph 32A PDUs, EMEA (wye)

3ph 32A PDUs, EMEA (wye)

  • For 9835-425: (#1026)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • Prerequisites: None
    • Corequisites: None
    • Compatibility conflicts: Cannot coexist with feature #1020 or #1025
    • Customer setup: Yes
    • Limitations: None
    • Plant / Field installable: Both
    • Cable order: None
    • Comments: None
(#1052) - 3ph 60A pin cords (IEC309)

In addition to selecting a single-phase or three-phase PDU feature, country and amperage specific line cords feature must be selected. The IBM FlashSystem A9000R Installation and Service Guide has additional information on power options. The feature provides three phase, 60A, pin cords (IEC309), non-EMEA delta cords. Two cords are included with each feature ordered.

  • For 9835-425: (#1052)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • Prerequisites: Feature #1025
    • Corequisites: None
    • Compatibility conflicts: Cannot coexist with feature #1054, #1055, or #1053
    • Customer setup: Yes
    • Limitations: None
    • Plant / Field installable: Both
    • Cable order: None
    • Comments: None
(#1053) - 3ph 32A hard wired EMEA wye

In addition to selecting a single-phase or three-phase PDU feature, country and amperage specific line cords feature must be selected. The IBM FlashSystem A9000R Installation and Service Guide has additional information on power options. The feature provides three phase, 32A, EMEA hard wired cords. Two cords are included with each feature ordered.

  • For 9835-425: (#1053)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • Prerequisites: Feature #1026
    • Corequisites: None
    • Compatibility conflicts: Cannot coexist with feature #1054, #1055, or #1052
    • Customer setup: Yes
    • Limitations: None
    • Plant / Field installable: Both
    • Cable order: None
    • Comments: None
(#1054) - 1ph 60A pin cords (IEC309)

In addition to selecting a single-phase or three-phase PDU feature, country and amperage specific line cords feature must be selected. The IBM FlashSystem A9000R Installation and Service Guide has additional information on power options. The feature provides single phase, 60A, pin cords (IEC309). Two cords are included with each feature ordered.

  • For 9835-425: (#1054)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • Prerequisites: Feature #1020
    • Corequisites: None
    • Compatibility conflicts: Cannot coexist with feature #1055, #1052, or #1053
    • Customer setup: Yes
    • Limitations: #1054 or #1055 must be ordered if #1020 is present on the order; must be ordered in qty of 0 or 2
    • Plant / Field installable: Both
    • Cable order: None
    • Comments: None
(#1055) - 1ph 60A hard wired

In addition to selecting a single-phase or three-phase PDU feature, country and amperage specific line cords feature must be selected. The IBM FlashSystem A9000R Installation and Service Guide has additional information on power options. The feature provides single phase, 60A, hard wired cords. Two cords are included with each feature ordered.

  • For 9835-425: (#1055)
    • Minimum required: 0
    • Maximum allowed: 2 (Initial order maximum: 2)
    • Prerequisites: Feature #1020
    • Corequisites: None
    • Compatibility conflicts: Cannot coexist with feature #1054, #1052, or #1053
    • Customer setup: Yes
    • Limitations: #1054 or #1055 must be ordered if #1020 is present on the order; must be ordered in qty of 0 or 2
    • Plant / Field installable: Both
    • Cable order: None
    • Comments: None
(#1056) - 3ph 32A pin cords (IEC309), EMEA (wye)

The feature provides three phase, 32A EMEA (wye) pin cords (IEC309). Two cords are included with each feature ordered.

  • For 9835-425: (#1056)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • Prerequisites: Feature #1026
    • Corequisites: None
    • Compatibility conflicts: Cannot coexist with feature #1053, #1054, #1055, or #1052
    • Customer setup: Yes
    • Limitations: None
    • Plant / Field installable: Both
    • Cable order: None
    • Comments: None
(#1073) - 4th Grid-Element Cable Bundle

This feature provides brackets and a bundle of cables required for configurations populating a 4th grid element (including grid controllers and a flash enclosure) in the upper half of the rack.

  • For 9835-425: (#1073)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • Prerequisites: None
    • Corequisites: None
    • Compatibility conflicts: None
    • Customer setup: Yes
    • Limitations: None
    • Plant / Field installable: Both
    • Cable order: None
    • Comments: None
(#5003) - Grid controller with 4x 16G FC + 2x 10G iSCSI

This feature provides a grid controller with 4 x 16Gb FC ports and 2 x 10Gb iSCSI ports.

  • For 9835-425: (#5003)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 8)
    • Prerequisites: None
    • Corequisites: None
    • Compatibility conflicts: Cannot coexist with feature #5004
    • Customer setup: N/A
    • Limitations: Must be ordered in quantities of 4, 6, or 8, and must double the quantity of feature #AFE4, #AFE5, or #AFE6 in the order
    • Plant / Field installable: Initial
    • Cable order: None
    • Comments: None
(#5004) - Grid controller with 4x 10G iSCSI

This feature provides a grid controller with 4 x 10Gb iSCSI ports.

  • For 9835-425: (#5004)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 8)
    • Prerequisites: None
    • Corequisites: None
    • Compatibility conflicts: Cannot coexist with feature #5003 or #5005
    • Customer setup: No
    • Limitations: Must be ordered in quantities of 4, 6, or 8, and must double the quantity of feature #AFE4, #AFE5, or #AFE6 in the order
    • Plant / Field installable: Both
    • Cable order: None
    • Comments: None
(#5005) - Grid controller with 4x 16G FC/FC-NVMe + 2x 10G iSCSI

This feature provides a grid controller with 4 x 16Gb FC/FC-NVMe ports and 2 x 10Gb iSCSI ports.

  • For 9835-425: (#5005)
    • Minimum required: 0
    • Maximum allowed: 8 (Initial order maximum: 8)
    • Prerequisites: None
    • Corequisites: None
    • Compatibility conflicts: Cannot coexist with feature #5004
    • Customer setup: No
    • Limitations: Must be ordered if no feature #5004 is ordered. Must be ordered in quantities of 4, 6, or 8, and must double the quantity of feature #AFE4, #AFE5, or #AFE6 in the order
    • Plant / Field installable: Both
    • Cable order: None
    • Comments: None
(#5901) - Fiber optics (LC to LC)

Fiber optics (LC to LC)

  • For 9835-425: (#5901)
    • Minimum required: 0
    • Maximum allowed: 99 (Initial order maximum: 99)
    • Prerequisites: None
    • Corequisites: None
    • Compatibility conflicts: None
    • Customer setup: Yes
    • Limitations: None
    • Plant / Field installable: Both
    • Cable order: None
    • Comments: None
(#5902) - Fiber optics (LC to SC)

Fiber optics (LC to SC)

  • For 9835-425: (#5902)
    • Minimum required: 0
    • Maximum allowed: 99 (Initial order maximum: 99)
    • Prerequisites: None
    • Corequisites: None
    • Compatibility conflicts: None
    • Customer setup: Yes
    • Limitations: None
    • Plant / Field installable: Both
    • Cable order: None
    • Comments: None
(#AFAX) - Encryption Disable indicator

Encryption Disable indicator

  • For 9835-425: (#AFAX)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • Prerequisites: None
    • Corequisites: None
    • Compatibility conflicts: None
    • Customer setup: N/A
    • Limitations: Must be present if the order comes from China
    • Plant / Field installable: Initial
    • Cable order: None
    • Comments: None
(#AFE4) - Flash Enclosure with 12 x 3.6TB MicroLatency modules

This feature provides a flash enclosure fully populated with 12x 3.6TB IBM MicroLatency modules.

  • For 9835-425: (#AFE4)
    • Minimum required: 0
    • Maximum allowed: 4 (Initial order maximum: 4)
    • Prerequisites: None
    • Corequisites: None
    • Compatibility conflicts: Cannot coexist with feature #AFE5 or #AFE6
    • Customer setup: No
    • Limitations: Must be ordered in quantities of 2, 3, or 4, and must be ordered if no feature #AFE5 or #AFE6 is ordered
    • Plant / Field installable: Both
    • Cable order: None
    • Comments: None
(#AFE5) - Flash Enclosure with 12 x 8.5TB MicroLatency modules

This feature provides a flash enclosure fully populated with 12x 8.5TB IBM MicroLatency modules.

  • For 9835-425: (#AFE5)
    • Minimum required: 0
    • Maximum allowed: 4 (Initial order maximum: 4)
    • Prerequisites: None
    • Corequisites: None
    • Compatibility conflicts: Cannot coexist with feature #AFE4 or #AFE6
    • Customer setup: No
    • Limitations: Must be ordered in quantities of 2, 3, or 4, and must be ordered if no feature #AFE5 or #AFE6 is ordered
    • Plant / Field installable: Both
    • Cable order: None
    • Comments: None
(#AFE6) - Flash Enclosure with 12 x 18TB MicroLatency modules

This feature provides a flash enclosure fully populated with 12x 18TB IBM MicroLatency modules.

  • For 9835-425: (#AFE6)
    • Minimum required: 0
    • Maximum allowed: 4 (Initial order maximum: 4)
    • Prerequisites: None
    • Corequisites: None
    • Compatibility conflicts: Cannot coexist with feature #AFE4 or #AFE5
    • Customer setup: No
    • Limitations: Must be ordered in quantities of 2, 3, or 4, and must be ordered if no feature #AFE4 or #AFE5 is ordered
    • Plant / Field installable: Both
    • Cable order: None
    • Comments: None
(#AFR1) - Rear Water-Cooled Door

Rear Water-Cooled Door

  • For 9835-425: (#AFR1)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • Prerequisites: None
    • Corequisites: None
    • Compatibility conflicts: None
    • Customer setup: Yes
    • Limitations: None
    • Plant / Field installable: Both
    • Cable order: None
    • Comments: None
(#AFR2) - Height Reduction

Height Reduction

  • For 9835-425: (#AFR2)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • Prerequisites: None
    • Corequisites: None
    • Compatibility conflicts: Cannot coexist with feature #AFR3
    • Customer setup: N/A
    • Limitations: None
    • Plant / Field installable: Initial
    • Cable order: None
    • Comments: None
(#AFR3) - Weight Reduction

Weight Reduction

  • For 9835-425: (#AFR3)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • Prerequisites: None
    • Corequisites: None
    • Compatibility conflicts: Cannot coexist with feature #AFR2
    • Customer setup: N/A
    • Limitations: None
    • Plant / Field installable: Initial
    • Cable order: None
    • Comments: None
(#AFR5) - RFID Labeling

RFID Labeling

  • For 9835-425: (#AFR5)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • Prerequisites: None
    • Corequisites:
    • Compatibility conflicts: None
    • Customer setup: Yes
    • Limitations: None
    • Plant / Field installable: Both
    • Cable order: None
    • Comments: None
(#AFR6) - Door lock

Door lock

  • For 9835-425: (#AFR6)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • Prerequisites: None
    • Corequisites:
    • Compatibility conflicts: None
    • Customer setup: Yes
    • Limitations: None
    • Plant / Field installable: Both
    • Cable order: None
    • Comments: None
(#AFZA) - Cisco UCS Attachment Ind

Cisco UCS Attachment Ind

  • For 9835-425: (#AFZA)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • Prerequisites: None
    • Corequisites: None
    • Compatibility conflicts: None
    • Customer setup: N/A
    • Limitations: None
    • Plant / Field installable: Initial
    • Cable order: None
    • Comments: None
(#AG00) - Shipping and Handling NC

This feature indicates that the order will have no shipping and handling charges.

  • For 9835-425: (#AG00)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • Prerequisites: None
    • Corequisites: None
    • Compatibility conflicts: None
    • Customer setup: N/A
    • Limitations: Must be ordered if no feature #AG9L is ordered
    • Plant / Field installable: Initial
    • Cable order: None
    • Comments: None
(#AG9L) - Chargeable Shipping and Handling

Chargeable Shipping and Handling

  • For 9835-425: (#AG9L)
    • Minimum required: 0
    • Maximum allowed: 1 (Initial order maximum: 1)
    • Prerequisites: None
    • Corequisites: None
    • Compatibility conflicts: None
    • Customer setup: N/A
    • Limitations: Must be ordered if no feature #AG00 is ordered
    • Plant / Field installable: Initial
    • Cable order: None
    • Comments: None

Back to topBack to top
 
Accessories

None.

Customer replacement parts

None.
Back to topBack to top
 

Supplies

None.

Supplemental media

None.

Trademarks

(R), (TM), * Trademark or registered trademark of International Business Machines Corporation.

** Company, product, or service name may be a trademark or service mark of others.
 © IBM Corporation 2018.
Back to topBack to top

Contact IBM

Feedback